1 1407 W. North Temple, Suite 330 Salt Lake City, Utah February 9, 2016 VIA ELECTRONIC FILING AND HAND DELIVERY Public Service Commission of Utah Heber M. Wells Building, 4 th Floor 160 East 300 South Salt Lake City, UT Attn: Gary Widerburg Commission Secretary RE: Advice No Proposed Changes to Schedule 140, Non-Residential Energy Efficiency Program Docket No Enclosed for filing are an original and five (5) copies of proposed tariff sheets associated with Tariff P.S.C.U No. 50 of PacifiCorp, d.b.a. Rocky Mountain Power (the Company ), applicable to electric service in the State of Utah. Pursuant to the requirement of Rule R (D), the Company states that the proposed tariff sheets do not constitute a violation of state law or Commission rule. The Company will also provide an electronic version of this filing to psc@utah.gov. The Company respectfully requests an effective date of March 10, 2016 for these changes. Third Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency Second Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency Second Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency Second Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency

2 Public Service Commission of Utah February 9, 2016 Page 2 First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency First Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency Second Revision of Sheet No Schedule 140 Non-Residential Energy Efficiency The purpose of this filing is to propose changes to the Non-Residential Energy Efficiency Program ( Program ) administered through Electric Service Schedule No. 140, specifically to decrease lighting incentives and other measure updates as further described below. These tariff changes are proposed for management to targets illustrated in Figure 1 below, and filed in the Demand Side Management November 1 st Deferred Account and Forecast Report on November 2, 2015, in Docket No ( Nov 1 st Report ). Proposed changes to the Schedule 140 tariff sheets are included as Exhibit A. Figure Budget and Savings Forecast from Nov 1 st Report Description of Changes Proposed adjustments are listed below, with further necessary explanation provided in subsequent sections. 1. Adjust tariff language to define all prescriptive measure incentives as a maximum not-toexceed, or up-to amount. Implementing a maximum incentive rate, with an associated adjustable offered incentive rate will allow the Program to adjust incentives rapidly in response to changes to efficiency standards and market costs, and to align with available Program budgets. 2. Exclude lighting energy efficiency projects from Bill Credit eligibility since it pays a disproportionately higher level of customer project costs (80%) than necessary to influence a customer to implement a lighting project or is paid by prescriptive lighting incentives. 3. Change retrofit lighting incentives for all technologies to a pay-for-savings rate ($/annual kwh saved), excluding re-lamp measures which will continue to be paid per lamp replaced. To better align incentives with savings, customers will receive a higher incentive for lighting configurations and technologies that save more energy. 4. In response to declining costs for mainstream commercial LED technologies, reduce lighting incentives to target an average of 30-40% of customer incremental project costs. 5. Adjust incentives or measure caps for the following listed measures in response to changes in costs, eligibility criteria, baseline changes, or other market developments: Evaporative pre-cooler, commercial refrigerators and freezers, network PC power management, milk pre-coolers, refrigerator/freezer recycling, and residential room air conditioner/dishwasher/refrigerator/electric water heater/heat pump water heater used in a business.

3 Public Service Commission of Utah February 9, 2016 Page 3 6. Update tariff language for the midstream delivery channel to enable addition of new Tubular LED (TLED) measure. Explanation of Changes Maximum Up-to s - Enable the ability to make adjustments to the incentives periodically to address market conditions, changes in material costs, product availability, price competition and budgets. Maximum incentive amounts will be included in Schedule 140, however current offered incentive amounts for approved energy efficiency measures will be explicitly defined on the Company website. levels within the maximum incentive range may change with a minimum 45 days notice, which will be prominently displayed on the program website and will be communicated to stakeholders. Retailers and trade allies who participate in the Program will be notified preceding the date of the change. The Company proposes to establish maximum incentive levels in this filing as well as set initial offered incentive levels below the maximum range. Subsequent offered incentive levels will be adjustable within the maximum incentive range via the 45 days notice process as described above. The c/e analysis, attached hereto as Exhibit B, was based on the maximum incentive levels. Changes to Lighting Measures LED technology has become the predominant lighting technology in energy efficiency projects, and the Company anticipates this trend to continue. Long lamp life (30,000 hrs+), reduced lifetime maintenance costs, absence of hazardous materials (i.e. mercury), controllability, and higher efficacy (lumens/watt) and decreasing costs relative to traditional technologies have contributed to a shift toward using LED products on most energy efficiency projects. To address the continuing and rapid shift to more efficient LED technologies, the Company proposes to restructure the form and value of lighting incentives listed in Table 1a, 1b and 1c of schedule 140 as described below. Table 1a - Retrofit Lighting Energy Efficiency Measures Measure Category Eligibility Requirements Interior Lighting Exterior Lighting Lighting Retrofits TLED Relamp Fluorescent Relamp Lighting Retrofits Lamp wattage reduction of 10 Watts, No ballast or driver retrofit. Lamp wattage reduction of 3 Watts, No ballast retrofit. $0.15/kWh $10/lamp $1/lamp $0.15/kWh Offered $0.10/kWh $6/lamp $1/lamp $0.08/kWh Street/Pole $0.15/kWh $0.05/kWh

4 Public Service Commission of Utah February 9, 2016 Page 4 All retrofit lighting technologies will continue to be managed through qualified equipment lists. This requirement will continue to allow the program to pay only for lighting products that meet quality and safety standards. Interior Lighting Retrofit s. Add an Interior Lighting Retrofits category to pay a maximum of $0.15/annual kwh savings, replacing the prior prescriptive incentives offered by lighting technology. The initial offered incentive rate will be $0.10/kWh. To encourage the best lighting retrofit systems based on individual customer lighting needs, cost tolerance, and energy savings goals, and to incent all lighting technologies equally based on claimed energy savings, all retrofit lighting incentives are being adjusted to a pay for savings rate, excluding re-lamp measures. This incentive adjustment is anticipated to keep the Company on target with the energy savings targets and budget listed in Figure 1 above. Tubular LED and Fluorescent Re-lamps. Add a Tubular Light Emitting Diode (TLED) Relamp category to pay a maximum of $10/lamp installed. The initial offered incentive rate of $6/lamp installed. TLED lamps designed to fit in existing fluorescent lamp fixtures with existing fluorescent ballasts are a simple and cost effective option for many customers. Due to the maintenance nature of this measure, a per lamp incentive is recommended. TLED with ballast replacements provide more persistent, reliable savings and will be included in the retrofit lighting measure at the pay for savings rate. The Company will continue to offer a Fluorescent Relamp category to pay a maximum of $1/lamp installed. s for fluorescent relamps continue to provide low capital cost energy savings. General Exterior Lighting Retrofit s. Add an Exterior Lighting Retrofit measure to pay a maximum of $0.15/annual kwh savings. The initial offered incentive rate will be $0.08/kWh. Exterior lighting retrofits do not significantly affect utility demand savings, yet continue to provide energy savings to both the utility and customer. The incentive rate is lower than interior offerings to account for lower benefit to the program. This incentive adjustment is anticipated to keep the Company on target with the energy savings targets and budget listed in Figure 1 above. Street/Pole Exterior Lighting Retrofit s. Add a street/pole measure to pay a maximum of $0.15/annual kwh savings. The initial offered incentive rate will be $0.05/kWh. Street/Pole retrofits do not significantly affect utility demand savings, yet continue to provide energy savings. LED street and pole lighting project economics are favorable to customers and a lower incentive than the general exterior lighting measure is appropriate.

5 Public Service Commission of Utah February 9, 2016 Page 5 Table 1b Lighting Controls and Non-General Illuminance s (Retrofit Only) Measure Category Eligibility Requirements Interior Lighting Control Occupancy Control Daylighting Control Advanced Daylighting Control PIR, Dual Tech, or Integral Sensor Must control interior fixtures with Continuous, Stepped, or Bi-level ballast or automated control that dims 50% or more of the fixture in response to daylight. Must incorporate both an occupancy sensor and daylighting sensor operating as part of the same control sequence in the same interior space. $0.30/Watt controlled $0.34/Watt controlled $0.38/Watt controlled Offered $0.30/Watt controlled $0.34/Watt controlled $0.38/Watt controlled Exterior Lighting Control Exterior Dimming Control Must control LED technology in an exterior lighting application. Control must be integral to LED fixture or fixture-mounted and reduce fixture power by 75% or more for a minimum of 6 hrs per night or when the space has been unoccupied for 15 minutes or less. $0.34/Watt controlled $0.34/Watt controlled Non-General Illuminance Exit Sign LED Message Center Sign LED Channel Letter Sign LED Marquee/Cabinet Sign LED Case Lighting Reach-in Case LED or photoluminescent replacing incandescent or fluorescent LED replacing existing incandescent signage LED replacing existing neon or fluorescent signage LED replacing existing fluorescent signage LED replacing fluorescent lamp in refrigerated cases. LED must be listed on qualified equipment list. $15/Sign $5/Lamp $5/Linear Foot $5/Linear Foot $10/linear foot $15/Sign $5/Lamp $5/Linear Foot $5/Linear Foot $10/linear foot LED Case Lighting Open Case $10/linear foot $10/linear foot Refrigerated Case Occupancy Sensor Custom Custom Not listed above Installed in existing refrigerated case with LED lighting $1/linear foot $1/linear foot $0.15/kWh annual energy savings $0.10/kWh annual energy savings Interior Lighting Controls. Adjust the existing Lighting Control to reflect interior and exterior applications separately. Through adding Interior to the existing lighting control measure it will classify occupancy, daylighting, and advanced daylighting lighting control categories as specific to interior lighting applications. The Company will revise control savings factor values used for calculating energy savings for lighting controls measures. Recent program evaluations and a review of

6 Public Service Commission of Utah February 9, 2016 Page 6 control savings factors (CSF) from the Department of Energy (DOE), Regional Technical Forum (RTF), and Lawrence Berkeley National Labs (LBNL) has shown that current values for most incented control types are within industry standards, but integral occupancy sensors and advanced daylighting control CSFs should be increased. Exterior Lighting Control, Exterior Dimming Control. Add a new incentive offering for exterior LED dimming controls. LED lighting technology has increased the lighting control options in the market. Exterior dimming controls have high savings potential due to long hours of use. Savings will be calculated using a programmed control savings fraction in the lighting calculator tool. The incentive will be based on connected wattage in alignment with other retrofit lighting control offerings. LED Case Lighting. Move this incentive offering from the food service category where incentives are not capped to the Non-General Illuminance Lighting category where project incentive caps apply. The Company also will define sub-categories for reach-in and open cases and revise eligibility requirements. LED prices continue to drop and the program is beginning to see snap-in LED tubes being used to replace fluorescent lighting in refrigerated cases. These LED products can function on existing fluorescent ballasts and are less expensive than LED fixtures. Adding incentive caps aligns with the intent for this measure to have incentives cover a portion but not all of the measure cost. Through the creation of measure sub-categories the program will align with Regional Technical Forum (RTF) Uniform Energy Savings values for each case type. The Company will also add the requirement that LEDs be listed on a qualified equipment list to align with other LED offerings and industry best practice. Refrigerated Case Occupancy Sensor. Move the incentive offering from the food service category to the Non-General Illuminance Lighting category. This move will be to keep the refrigerated case measures in one incentive table. The Lighting Controls and Non-General Illuminance Lighting Table notes will be modified to include exterior dimming controls and add a note describing the location of the qualified equipment list.

7 Public Service Commission of Utah February 9, 2016 Page 7 Table 1c New Construction/Major Renovation Lighting s Measure Category Eligibility Requirements Interior Lighting Exterior Lighting Lighting and Lighting Control 1. The total connected interior lighting power for New Construction/Major Renovation projects must be at least 10% lower than the interior lighting power allowance calculated under the applicable version of the state energy code. For New Construction/Major Renovation projects not included in the state energy code, the total connected lighting power must be at least 10% lower than common practice as determined by the Company. 2. Energy savings is subject to approval by the Company Maximum $0.08/kWh annual energy savings Offered $0.08/kWh annual energy savings Induction Fixture All Wattages, New Fixtures Only $75/Fixture $25/Fixture LED Outdoor <75W; LED must be listed on qualified Pole/Roadway, equipment list decorative $75/Fixture $25/Fixture 200W; LED must be listed on qualified LED Outdoor equipment list $100/fixture $50/fixture Pole/Roadway >200W; LED must be listed on qualified equipment list $400/fixture $175/fixture LED Canopy/Soffit LED must be listed on qualified equipment list $125/fixture $50/fixture LED Wall Packs <50 Watts; LED must be listed on qualified equipment list $50/fixture $50/fixture 50 Watts; LED must be listed on qualified equipment list $75/fixture $50/fixture LED Flood Lights <100 Watts; LED must be listed on qualified equipment list $75/fixture $50/fixture 100 Watts; LED must be listed on qualified equipment list $150/fixture $100/fixture CFL Wall Pack All Wattages, Hardwire Fixtures Only $30/Fixture $10/Fixture Custom Exterior Dimming Control Not listed above Must control LED technology in an exterior lighting application. Control must be integral to LED fixture or fixturemounted and reduce fixture power by 75% or more for a minimum of 6 hrs per night or when the space has been unoccupied for 15 minutes or less. $0.08/kWh annual energy savings $0.34/Watt controlled** $0.08/kWh annual energy savings $0.34/Watt controlled** Exterior Lighting Fixtures. Change all incentives to a maximum, not-to-exceed, up-to incentive. Exterior LED costs have declined between 20-40% since the initial tariff offering for exterior LED measures. The offered incentive rates have been reduced to reflect the changes in costs. Exterior Lighting Control, Exterior Dimming Control. Add a new incentive offering for exterior LED dimming controls.

8 Public Service Commission of Utah February 9, 2016 Page 8 LED lighting technology has increased the lighting control options. Exterior dimming controls have a high savings potential due to long hours of use. The savings will be calculated using a programmed control savings fraction in the lighting calculator tool and the incentive will be based on connected wattage in alignment with other retrofit lighting control offerings. Changes to HVAC Equipment and Controls s Evaporative Pre-cooler. Apply project incentive caps to this measure. In some cases incentives may cover the entire cost of the evaporative pre-cooler measure. Adding incentive caps aligns with the intent for this measure to have incentives cover a portion but not all of the measure cost. Changes to Food Service s Commercial Refrigerators and Freezers. Add a sunset date to this measure. More stringent federal standards for commercial refrigerators and freezers will be in effect for equipment manufacturers on March 27, Measure savings will be significantly reduced relative to the new federal standards baseline. Changes to Appliance s Electric Water Heater, residential used in a business. Remove this measure. Due to federal standards changes as of April 15, 2015 this measure is no longer eligible for incentives in the Home Energy Savings program and in alignment with the residential offering changes, this measure will be removed. Heat Pump Water Heater, residential used in a business. Add this as a new incentive measure in alignment with the proposed addition of this measure in Home Energy Savings. This will allow business customers who may wish to install a residential heat pump water heater at their business to receive the same incentive and meet the same requirements as would be available to a residential customer. Changes to Office s Network Power PC Management. Remove this measure. RTF has recently determined that Network PC Power Management software has become the industry standard and software is often available for little or no cost. The measure is removed in alignment with recent RTF evaluation. Changes to Farm and Dairy Change eligibility for milk pre-coolers to retrofit only as well as UES for variable frequency drives for dairy vacuum pumps based upon updated analysis. The proposed changes to align with industry and federal standards can be found in Exhibit A. These changes are not forecast to materially impact cost effectiveness.

9 Public Service Commission of Utah February 9, 2016 Page 9 Mid-Market s Tubular light emitting diodes (TLEDs). Add as an eligible measure within the midmarket incentive channel. Market acceptance of this technology has reached a point of standard customer replacements. This will allow business customers who may wish to install TLEDs through maintenance budgets over extended periods of time access to this incentive channel. Cost Effectiveness Tables 2 and 3 below, pulled from Exhibit B, present the expected cost-effectiveness of the revised wattsmart Business program, revised trade ally lighting delivery channel, and Mid- Market channel with its current measure offerings. Detailed inputs and results, including sensitivity analysis, are presented in Exhibit B. The program is expected to remain cost-effective from the Utility Cost Test and the Total Resource Cost Test perspectives under all scenarios. Table Wattsmart Business Program Costs Measure Year Admin Delivery Business as Usual Proposed with Changes Proposed with Changes +10% Participation Proposed with Changes 10% Participation Lighting Only Business as Usual Lighting Only with Proposed Changes Lighting Only with Proposed Changes +10% Participation Lighting Only with Proposed Changes 10% Participation s Total Utility Costs Participant Incremental Cost $1,600,000 $15,639,746 $62,883,463 $80,123,208 $146,429,541 $1,600,000 $15,639,746 $50,290,840 $67,530,585 $138,505,053 $1,600,000 $17,203,720 $55,319,924 $74,123,644 $152,355,559 $1,600,000 $14,075,771 $45,261,756 $60,937,527 $124,654,548 $400,000 $4,811,285 $29,344,849 $34,556,134 $71,333,845 $400,000 $4,811,285 $16,772,904 $21,984,189 $63,458,651 $400,000 $5,292,413 $18,450,195 $24,142,608 $69,804,516 $400,000 $4,330,156 $15,095,614 $19,825,770 $57,112,786

10 Public Service Commission of Utah February 9, 2016 Page 10 Table UT Wattsmart Business Program Annual Savings Measure Business as Usual Proposed with Changes Proposed with Changes +10% Participation Proposed with Changes 10% Participation Lighting Only Business as Usual Lighting Only with Proposed Changes Lighting Only with Proposed Changes +10% Participation Lighting Only with Proposed Changes 10% Participation Year Gross KWh Savings Realization Rate Adjusted KWh Savings Net to Gross Percentage Net KWh Savings Measure Life 451,861,903 95% 428,470,236 86% 369,433, ,457,930 95% 409,848,779 87% 354,849, ,503,723 95% 450,833,657 87% 390,334, ,412,137 95% 368,863,901 87% 319,364, ,919,492 88% 159,804,959 80% 128,206, ,937,059 89% 141,550,242 80% 113,789, ,930,765 89% 155,705,266 80% 125,168, ,943,353 89% 127,395,218 80% 102,410, The Program is funded through the Schedule 193 DSM Cost Adjustment. Any proposed adjustment to Schedule 193 will be informed by the next tariff rider analysis, which will examine the combined effect of the current balance, forecasted revenues and forecasted expenditures for all programs. The Company is not recommending an adjustment to Schedule 193 as part of this filing. It is respectfully requested that all formal correspondence and staff requests regarding this matter be addressed to: By (preferred): By regular mail: Data Request Response Center PacifiCorp 825 NE Multnomah Blvd., Suite 2000 Portland, OR 97232

11

12 EXHIBIT A

13 Third Revision of Sheet No P.S.C.U. No. 50 Canceling Second Revision of Sheet No INCENTIVES: 1 Category Percent Project Cost Cap 1-Year Simple Payback Cap for Projects 2 Other Limitations Prescriptive s * See Tables 1a-11 See Tables 1a-11 See Tables 1a-11 See Tables 1a-11 Mid-market s Custom Non-Lighting s for qualifying measures not on the prescriptive list. 3 Energy Management Energy Project Manager Co-Funding Bill Credit 4 Determined by Company with not-toexceed amounts as shown in Table 13 $0.15 per annual kwh savings $0.02 per kwh annual savings $0.025 per kwh annual savings 80% of eligible project costs N/A No s available at the point of purchase through approved distributors/retailers or via a post-purchase customer application process 70% Yes N/A N/A No N/A 100% of salary and eligible overhead No 80% No Minimum 1,000,000 kwh through qualified measures Customers with minimum 1 MW peak or annual usage of 5,000,000 kwh** *s for measures contained in Tables 1a-11 are restricted to the amounts shown in Tables 1a-11 or the appropriate bill credit amount. **Customers may aggregate accounts to achieve minimum requirements. (Continued) 1 The customer or Owner may receive only one financial incentive from the Company per measure. Financial incentives include energy efficiency incentive payments, bill credits, and energy management payments. Energy Project Manager Co-Funding is available in addition to the project incentives. 2 The 1 year simple payback cap means incentives will not be available to reduce the simple payback of a project below one year. If required, individual measure incentives will be adjusted downward pro-rata so the project has a simple payback after incentives of one year. 3 Project Cost and 1-Year Simple Payback Caps do not apply to New Construction and Major Renovation projects that are subject to state energy code. 4 To qualify for the bill credit option, a project must have a projected payback period of between 1 and 8 years. The Company may accept a project with a projected payback period in excess of eight years if project benefits satisfy the Commission s approved costeffectiveness test. New Construction, lighting retrofits and Pre-payment projects are not eligible for bill credit. Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

14 Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision of Sheet No Table 1a - Retrofit Lighting Energy Efficiency Measures Measure Category Eligibility Requirements Lighting Retrofits $0.15/kWh Interior Lighting TLED Relamp Lamp wattage reduction of 10 Watts, No ballast or driver retrofit. $10/lamp Fluorescent Relamp Lamp wattage reduction of 3 Watts, No ballast retrofit. $1/lamp Lighting Exterior Lighting Retrofits $0.15/kWh Street/Pole $0.15/kWh Notes for Table 1a: 1. To be eligible for the incentives listed, the new lighting system must use less energy than the existing lighting system replaced or the baseline lighting system as determined by the Company. 2. s are capped at 70 percent of Energy Efficiency Project Costs and will not be available to reduce the Energy Efficiency Project simple payback below one year. Energy Efficiency Project costs are subject to Company approval. 3. s for TLED Fluorescent Relamps may not be combined with other lamp or fixture incentives and will only be paid once per facility. 4. Eligibale retrofit lighting equipment is defined in qualified equipment lists posted on the Utah energy efficiency program section of the Company s website. (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

15 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 1b Lighting Controls and Non-General Illuminance s (Retrofit Only) Measure Category Eligibility Requirements Occupancy Control PIR, Dual Tech, or Integral Sensor $0.30/Watt controlled Interior Lighting Control Daylighting Control Advanced Daylighting Control Must control interior fixtures with Continuous, Stepped, or Bi-level ballast or automated control that dims 50% or more of the fixture in response to daylight. Must incorporate both an occupancy sensor and daylighting sensor operating as part of the same control sequence in the same interior space. $0.34/Watt controlled $0.38/Watt controlled Exterior Lighting Control Exterior Dimming Control Must control LED technology in an exterior lighting application. Control must be integral to LED fixture or fixturemounted and reduce fixture power by 75% or more for a minimum of 6 hrs per night or when the space has been unoccupied for 15 minutes or less. $0.34/Watt controlled (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

16 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 1b Lighting Controls and Non-General Illuminance s (Retrofit Only) (Continued) Measure Category Eligibility Requirements Non-General Illuminance Exit Sign LED Message Center Sign LED Channel Letter Sign LED Marquee/Cabinet Sign LED Case Lighting Reach-in Case LED Case Lighting Open Case Refrigerated Case Occupancy Sensor LED or photoluminescent replacing incandescent or fluorescent LED replacing existing incandescent signage LED replacing existing neon or fluorescent signage LED replacing existing fluorescent signage LED replacing fluorescent lamp in refrigerated cases. LED must be listed on qualified equipment list. Installed in existing refrigerated case with LED lighting Custom Custom Not listed above $15/Sign $5/Lamp $5/Linear Foot $5/Linear Foot $10/linear foot $10/linear foot $1/linear foot $0.15/kWh annual energy savings Notes for Table 1b: 1. To be eligible for the incentives listed, the new lighting system must use less energy than the existing lighting system replaced or the baseline lighting system as determined by the Company. 2. s are capped at 70 percent of Energy Efficiency Project Costs and incentives will not be available to reduce the Energy Efficiency Project simple payback below one year. Energy Efficiency Project Costs are subject to Company approval. 3. s for Advanced Daylighting Controls may not be combined with Occupancy Control or Daylighting Control incentives. 4. Watt controlled refers to the total wattage of lighting fixtures down circuit from the control. 5. Qualified equipment lists for measures referenced in the above table are posted on the Utah energy efficiency program section of the Company s website. PIR = Passive Infrared Dual Tech = Sensors combining ultrasonic and passive infrared LED - Light-emitting Diode (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

17 Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision of Sheet No Table 1c New Construction/Major Renovation Lighting s Measure Category Eligibility Requirements Interior Lighting* Lighting and Lighting Control 1. The total connected interior lighting power for New Construction/Major Renovation projects must be at least 10% lower than the interior lighting power allowance calculated under the applicable version of the state energy code. For New Construction/Major Renovation projects not included in the state energy code, the total connected lighting power must be at least 10% lower than common practice as determined by the Company. 2. Energy savings is subject to approval by the Company $0.08/kWh annual energy savings Induction Fixture All Wattages, New Fixtures Only $75/Fixture LED Outdoor <75W; LED must be listed on qualified equipment Pole/Roadway, decorative list $75/Fixture 200W; LED must be listed on qualified equipment LED Outdoor list $100/fixture Pole/Roadway >200W; LED must be listed on qualified equipment list $400/fixture LED Canopy/Soffit LED must be listed on qualified equipment list $125/fixture LED Wall Packs <50 Watts; LED must be listed on qualified equipment list $50/fixture 50 Watts; LED must be listed on qualified equipment list $75/fixture Exterior Lighting <100 Watts; LED must be listed on qualified $75/fixture equipment list LED Flood Lights 100 Watts; LED must be listed on qualified $150/fixture equipment list CFL Wall Pack All Wattages, Hardwire Fixtures Only $30/Fixture Custom Not listed above $0.08/kWh annual energy savings Exterior Dimming Control Must control LED technology in an exterior lighting application. Control must be integral to LED fixture or fixture-mounted and reduce fixture power by 75% or more for a minimum of 6 hrs per night or when the space has been unoccupied for 15 minutes or less. e $0.34/Watt controlled** *Project Cost Caps of 70% and 1-Year Simple Payback Caps apply to New Construction and Major Renovation projects that are not subject to state energy code. The 1 year simple payback cap means incentives will not be available to reduce the simple payback of a project below one year. If required, individual measure incentives will be adjusted downward pro-rata so the project has a simple payback after incentives of one year. ** Exterior lighting controls required by the applicable version of the state energy code are not eligible for incentives. CFL Compact Fluorescent Lamp LED - Light-Emitting Diode (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

18 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 2 - Motor s Equipment Type Size Category Sub-Category Minimum Efficiency Requirement Electronically 1 horsepower Refrigeration application -- $0.50/watt Commutated Motor (ECM) HVAC application -- $50/horsepower Variable-Frequency 100 horsepower HVAC fans and pumps See Note 2 $65/horsepower Drives (HVAC fans and pumps) Green Motor Rewinds 15 and 5,000 horsepower -- Must meet GMPG Standards $1/horsepower Refer to Note 3 Notes for Table 2: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. Throttling or bypass devices, such as inlet vanes, bypass dampers, three-way valves, or throttling valves must be removed or permanently disabled to qualify for HVAC fan or pump VFD incentives. VFDs required by or used to comply with the applicable version of the energy code are not eligible for incentives. Savings will only be realized for installations where a variable load is present. 3. For Green Motor Rewinds, the participating electric motor service center is paid $2/horsepower for eligible Green Motor Rewinds. A minimum of $1/horsepower is paid by the service center to the Customer as a credit on the motor rewind invoice. The balance is retained by the service center. Green Motor Rewind motors that are installed or placed in inventory may qualify for an incentive. ECM = Electronically Commutated Motor GMPG = Green Motors Practices Group HVAC = Heating, Ventilation and Air Conditioning NEMA = National Electrical Manufacturer s Association VFD = Variable Frequency Drive (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

19 Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision of Sheet No Table 3a HVAC s Minimum Efficiency Requirement & Equipment Type Size Category Sub-Category $25/ton $50/ton $75/ton Unitary Commercial Air Conditioners, Air- Cooled (Cooling Mode) Unitary Commercial Air Conditioners, Water and Evaporatively Cooled (See Note 8) Packaged Terminal Air Conditioners (PTAC) (Cooling Mode) Packaged Terminal Heat Pumps (PTHP) (Heating & Cooling Mode) Heat Pumps, Air- Cooled (Cooling Mode) Heat Pumps, Air- Cooled (Heating Mode) - See Note 3 Heat Pumps, Water- Source (Cooling Mode) < 65, 000 Btu/hr (single phase) All equipment sizes (three phase) All equipment sizes Split system and single package Split system and single package Split system and single package -- CEE Tier 2 -- CEE Tier 1 CEE Tier 2 -- CEE Tier ,000 Btu/hr Single package 12.2 EER > 8,000 Btu/hr and < 10,500 Btu/hr Single package 11.9 EER ,500 Btu/hr and 13,500 Single package 10.7 EER Btu/hr > 13,500 Btu/hr Single package 9.9 EER ,000 Btu/hr Single package EER and 3.4 COP -- > 8,000 Btu/hr and 11.5 EER and 3.3 Single package -- < 10,500 Btu/hr COP -- 10,500 Btu/hr 10.7 EER and 3.1 and 13,500 Single package -- COP Btu/hr -- > 13,500 Btu/hr Single package EER and 3.0 COP -- < 65, 000 Btu/hr Split system and (single phase) single package -- CEE Tier 2 < 65, 000 Btu/hr Split system and -- CEE Tier 2 (three phase) single package CEE Tier 1 65,000 Btu/hr Split system and (three phase) single package < 65, 000 Btu/hr Split system and (single phase) single package -- CEE Tier 2 < 65, 000 Btu/hr Split system and (three phase) single package -- CEE Tier 2 65,000 Btu/hr (three phase) 47 F db/43 F wb outdoor air 17 F db/15 F wb outdoor air -- CEE Tier < 135,000 Btu/hr 86 F Entering Water -- CEE Tier 1 -- (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

20 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 3a HVAC s (Continued) Minimum Efficiency Requirement & Equipment Type Size Category Sub-Category $25/ton $50/ton $75/ton Heat Pumps, Water- Source (Heating Mode) - See Note 3 < 135,000 Btu/hr 68 F Entering Water -- CEE Tier 1 -- VRF Air-Cooled Heat Pumps (Cooling Mode) VRF Air-Cooled Heat Pumps (Heating Mode) VRF Water-Cooled Heat Pumps (Cooling Mode) VRF Water-Cooled Heat Pumps (Heating Mode) Heat Pumps, Ground- Source or Groundwater-Source (Heating & Cooling Mode) - See Note 3 All Equipment Sizes All Equipment Sizes < 135,000 Btu/hr < 135,000 Btu/hr Multisplit System or Multisplit System with Heat Recovery Multisplit System or Multisplit System with Heat Recovery (See note 3) Multisplit System or Multisplit System with Heat Recovery Multisplit System or Multisplit System with Heat Recovery (See note 3) 77 F Entering Water -- CEE Tier 1 CEE Tier 1 CEE Tier 1 CEE Tier 1 ENERGY STAR Qualified -- All sizes Ground Source or Groundwater-Source Heat Pump Loop All sizes $25/ton Notes for table 3a - HVAC equipment incentive table 1. Equipment that meets or exceeds the efficiency requirements listed for the size category in the above table may qualify for the listed incentive. Equipment must meet all listed efficiency requirements to qualify for the listed incentives. 2. PTHPs can replace electric resistive heating, which must be removed. 3. s for heat pumps are available per ton of cooling capacity ONLY. No incentives are paid per ton of heating capacity. Heat Pumps must meet both the cooling mode and heating mode efficiency requirements to qualify for per ton cooling efficiency incentives. 4. Equipment size categories and capacities are specified in terms of net cooling capacity at AHRI standard conditions as determined by AHRI Standard 210/240 for units <65,000 Btu/hr, AHRI Standard 340/360 for units 65,000 Btu/hr, AHRI Standard 310/380 for PTAC and PTHP units, and AHRI Standard 1230 for VRF systems. 5. Ground and Water Source Heat Pumps must meet or exceed listed efficiency requirements when rated in accordance with ISO to qualify for the listed incentive. 6. Units rated with an IPLV may qualify for the listed incentives if the value meets or exceeds the minimum IPLV established in the Consortium for Energy Efficiency Commercial Unitary Air Conditioning and Heat Pump specification effective January 16, Efficiency requirements align with the Unitary Air-Conditioning and Heat Pump Specification maintained by the Consortium for Energy Efficiency for equipment with heating sections other than electric resistance. CEE minimum efficiency requirements are listed on the Company website. (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

21 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Notes for table 3a - HVAC equipment incentive table (continued) AHRI = Air-Conditioning, Heating, and Refrigeration Institute IEER = Integrated Energy Efficiency Ratio CEE = Consortium for Energy Efficiency IPLV = Integrated Part Load Value COP = Coefficient of Performance PTAC = Packaged Terminal Air Conditioner EER = Energy Efficiency Ratio PTHP = Packaged Terminal Heat Pump HSPF = Heating Seasonal Performance Factor SEER = Seasonal Energy Efficiency Ratio HVAC = Heating, Ventilation and Air-Conditioning VFR = Variable Refrigerant Flow Table 3b Other HVAC s Equipment Type Size Category Sub-Category Minimum Efficiency Requirement Evaporative Cooling All sizes Direct or Indirect $0.06/ CFM Indirect-Direct Evaporative Cooling (IDEC) Chillers 365/366 day Programmable or Occupancy-based Thermostat Occupancy Based PTHP/PTAC control Evaporative Pre-cooler (Retrofit Only) All sizes -- Applicable system components must exceed minimum efficiencies required by energy code All except chillers intended for backup service only All sizes in portable classrooms with mechanical cooling All sizes with no prior occupancy based control Serving primarily occupant comfort cooling loads (no more than 20% for process cooling loads) Must be installed in portable classroom unoccupied during summer months For single aircooled packaged rooftop or matched split system condensers only Must exceed minimum efficiencies required by energy code 365/366 day thermostatic or occupancy based setback capability See Note 5 Minimum performance efficiency of 75%. Must have enthalpy controls to control pre-cooler operation. Water supply must have chemical or mechanical water treatment. $0.15/kWh annual energy savings See Note 2 $0.15/kWh annual energy savings See Note 3 $150/thermostat $50/controller $75/ton of attached cooling capacity (See Note 5) Notes for Table 3b 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. s paid at $0.15/kWh annual energy savings. IDEC energy savings subject to approval by the Company. 3. s paid at $0.15/kWh annual energy savings. Chiller energy savings subject to approval by the Company. 4. Controller units must include an occupancy based control and include the capability to set back the zone temperature during extended unoccupied periods and set up the temperature once the zone is occupied. 5. s for Evaporative Pre-coolers are capped at 70 percent of Energy Efficiency Project Costs and incentives will not be available to reduce the Energy Efficiency Project simple payback below one year. 6. Energy Efficiency Project Costs are subject to Rocky Mountain Power approval. CFM = Cubic Feet per Minute HVAC = Heating, Ventilating and Air Conditioning IDEC = Indirect Direct Evaporative Cooling PTAC = Packaged Terminal Air Conditioner PTHP = Packaged Terminal Heat Pump (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

22 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 4a Building Envelope s (Retrofit) Equipment Type Category Minimum Efficiency Requirement Cool Roof -- ENERGY STAR Qualified Roof/Attic Insulation -- Wall Insulation -- Windows (See Note 3, 4) Site-Built Assembly Minimum increment of R-10 insulation added Minimum increment of R-10 insulation added U-Factor 0.30 and SHGC 0.33 (Glazing Only Rating) U-Factor 0.30 and SHGC 0.33 (Entire Window Assembly Rating) Window Film Existing Windows See Note 5 $0.10/square foot $0.05/square foot $0.07/square foot $0.35/square foot $0.35/square foot $0.15/kWh annual energy savings (See Note 5) Notes for Table 4a: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. Building must be conditioned with mechanical cooling to be eligible for envelope incentives. 3. Energy performance of window assemblies and glazing products must be rated in accordance with NFRC. Site-Built metal window systems must include a thermal break within the frame or other appropriate NFRC certification to qualify for incentives. Skylights are not eligible to receive the incentives in the above table. 4. Window square footage is determined by the dimensions of the entire window assembly, not just the window glass. 5. s for window film are calculated based on film specifications and window orientation at $0.15/kWh annual energy savings. Energy savings are subject to approval by the Company. NFRC = National Fenestration Rating Council SHGC = Solar Heat Gain Coefficient Table 4b Building Envelope s (New Construction/Major Renovation) Equipment Type Category Minimum Efficiency Requirement Cool Roof -- ENERGY STAR Qualified Roof/Attic Insulation -- Wall Insulation -- Windows (See Note 3, 4) Site-Built Assembly Minimum increment of R-5 insulation above code (See Note 5) Minimum increment of R-3.7 continuous insulation above code (See Note 5) U-Factor 0.30 and SHGC 0.33 (Glazing Only Rating) U-Factor 0.30 and SHGC 0.33 (Entire Window Assembly Rating) (Continued) $0.10/square foot $0.05/square foot $0.07/square foot $0.35/square foot $0.35/square foot Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

23 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 5 Food Service Equipment s Equipment Type Equipment Category Minimum Efficiency Requirement /Unit Residential Dishwasher Used in a Business See Home Energy Savings Program See Note 2 Undercounter $100 Commercial Dishwasher Stationary Rack, Single Tank, (High Temperature models w/ $400 Door Type ENERGY STAR Qualified electric boosters only) Single Tank Conveyor $1,000 Multiple Tank Conveyor $500 Electric Insulated Holding Cabinet Electric Steam Cooker V 28 $ V < 28 ENERGY STAR Qualified $300 V < 13 $200 3-, 4-, 5- and 6-pan or larger sizes - Tier 1 ENERGY STAR Qualified $130 3-, 4-, 5- and 6-pan or larger sizes - Tier 2 ENERGY STAR Qualified w/ Heavy Load Efficiency 68% Electric Convection Oven -- ENERGY STAR Qualified $350 Electric Griddle ENERGY STAR Tier 2 Qualified $150 $300 Electric Combination Oven 6-14 pans ENERGY STAR Qualified $1, pans ENERGY STAR Qualified $275 Electric Commercial Fryer Ice Machines (Air-Cooled Only) Tier 1 ENERGY STAR Qualified $200 Tier 2 ENERGY STAR Qualified w/cooking Efficiency 85%, Idle Energy Rate 860 Watts $300 Tier 1: Harvest Rate < 500 $125 lbs/day ENERGY STAR Qualified Tier 1: Harvest Rate 500 $150 lbs/day Tier 2: Harvest Rate < 500 lbs/day Tier 2: Harvest Rate 500 lbs/day CEE Tier 2 Qualified Residential Refrigerator Used in a Business See Home Energy Savings Program See Note 2 $250 $400 (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

24 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 5 Food Service Equipment s (Continued) Commercial Transparent Door Refrigerator (See Note 3) Commercial Transparent Door Freezer (See Note 3) Demand Controlled Kitchen Ventilation Exhaust Hood (Retrofit Only) Anti-Sweat Heater Controls (Retrofit Only) 0 < V < 15 $25 15 V < 30 $50 30 V < 50 ENERGY STAR Qualified $75 50 V $125 Chest Configuration $50 0 < V < 15 $25 15 V < 30 $50 30 V < 50 ENERGY STAR Qualified $75 50 V $100 Chest Configuration $100 Must be installed on commercial kitchen exhaust system. Low-Temp (Freezing) Cases Med-Temp (Refrigerated) Cases Variable speed motors must be controlled to vary fan speed depending upon kitchen demand, as indicated by connected sensors. Controls that reduce energy consumption of anti-sweat heaters based on sensing humidity. $0.15/kWh annual energy savings (See note 5) $20/linear foot (case length) $16/linear foot (case length) Notes for Table 5: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. s are paid at $0.15/kWh annual energy savings. Demand controlled kitchen ventilation exhaust hood energy savings subject to approval by Company. 3. s for commercial refrigerators and freezers will no longer be available effective March 27, CEE = Consortium for Energy Efficiency ASTM = American Society for Testing and Materials MDEC = Maximum Daily Energy Consumption V = Association of Home Appliance Manufacturers (AHAM) Volume (cubic feet) (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

25 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 6 Office Equipment s Equipment Type Minimum Efficiency Requirements Smart Plug Strip 1. applies to any plug strip that eliminates idle or stand-by power consumption of connected plug-load appliance through the use of an occupancy sensor, electric load sensor, or timer. 2. Applies only to electric plug-load applications (e.g. computer monitors, desk lamps, etc.) $15/qualifying unit Notes for Table 6: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

26 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Equipment Type High-Efficiency Clothes Washer Heat Pump Water Heater Table 7 Appliance s Equipment Category Residential (used in a business) Commercial (must have electric water heating) Residential (used in a business) Minimum Efficiency Requirement See Home Energy Savings Program See Note 3 ENERGY STAR Qualified $100 See Home Energy Savings Program Notes for Table 7: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. Equipment must meet the efficiency rating standard that is in effect on the date of purchase. 3. Refer to Company's Home Energy Savings program for efficiency requirements and incentives for listed residential appliances used in a business. (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

27 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 8a - Irrigation s - Measures for Wheel Line, Hand Line, or Other Portable Systems (Retrofit Only) Irrigation Measure Replace With Limitations Leaking or malfunctioning impact or rotating Rotating sprinkler sprinkler irrigated acre. New rotating sprinkler replacing worn or leaking impact or rotating sprinkler New or rebuilt impact sprinkler replacing worn or leaking impact sprinkler New nozzle replacing worn nozzle of same design flow or less on existing sprinkler New flow-control nozzle for impact sprinkler replacing existing nozzle or worn flow-control nozzle of same design flow or less New gasket replacing leaking gasket, including mainline valve or section gasket, seal, or riser cap (dome disc) New drain replacing leaking drain Cut and press or weld repair of leaking wheel line, hand line, or portable main line New or rebuilt wheel line leveler replacing leaking or malfunctioning leveler Leaking or malfunctioning impact sprinkler Worn nozzle Worn nozzle Leaking gasket Leaking drain Leak in wheel line, hand line, or portable main line Leaking or malfunctioning leveler New or rebuilt impact sprinkler New nozzle of same design flow or less New flow control nozzle New gasket, including mainline valve or section gasket, seal, or riser cap (dome disc) New drain, including drains on pivots and linears Cut and pipe press or weld repair New or rebuilt leveler (Continued) 1. Fixed-in-place (solid set) systems not eligible. 2. limited to two sprinklers per 1. New nozzle shall be included in new or rebuilt sprinkler. Rebuilt sprinkler shall meet or exceed manufacturer s specifications. 2. Fixed-in-place (solid set) systems not eligible. 3. limited to two sprinklers per irrigated acre. 1. Flow rate shall not be increased. 2. All nozzles on the wheel line or hand line shall be replaced. 3. Fixed-in-place (solid set) systems not eligible. 4. limited to two nozzles per irrigated acre. 1. Nozzle to be replaced may be fixed orifice or flow control type. 2. New flow control nozzle shall have a flow rating equal to or less than the flow rating of the existing nozzles at 40 psi. 3. All nozzles on the wheel line or hand line shall be replaced. 4. Fixed-in-place (solid set) systems not eligible. 5. limited to two nozzles per irrigated acre. 1. New gasket must replace leaking gasket. 2. Fixed-in-place (solid set) systems not eligible. 3. limited to two gaskets per irrigated acre. 1. New drain must replace leaking drain. 2. Fixed-in-place (solid set) systems not eligible. 3. limited to two drains per irrigated acre. 1. For rebuilds, invoice must show number of rebuild kits purchased and installed. 1. Applies to leaking or malfunctioning levelers only. 2. For rebuilds, invoice must show number of rebuild kits purchased and installed. Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016 $2.50 each $2.25 each $0.50 each $2.75 each $2 each $3 each $10/repair $3 each

28 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 8a - Irrigation s Measures for Wheel Line, hand Line, or Other Portable Systems (Retrofit Only) (Continued) Irrigation Measure Replace With Limitations New or rebuilt wheel line feed hose replacing leaking wheel line feed hose New Thunderbird wheel line hub replacing leaking wheel line hub Leaking wheel line feed hose Leaking Thunderbird wheel line hub New or rebuilt wheel line feed hose New Thunderbird wheel line hub 1. Applies to leaking wheel line feed hose only. 2. For rebuilds, invoice must show number of rebuild kits purchased and installed. New hub must replace leaking hub $12 each $10 each Table 8b - Irrigation s Measures for Pivots and Linear Systems (Retrofit Only) Irrigation Measure Replace With Limitations Pressure regulator Low pressure sprinkler (e.g. rotating, wobbling, multi-trajectory spray) replacing impact sprinkler Low pressure sprinkler (e.g. rotating, wobbling, multi-trajectory spray) replacing worn low pressure sprinkler Gooseneck as part of conversion to low pressure system Worn pressure regulator Impact sprinkler Worn low pressure sprinkler (e.g. rotating, wobbling, multi-trajectory spray) New pressure regulator of same design pressure or less New low pressure sprinkler (on-board nozzle is considered part of sprinkler, not a separate item with additional incentive) New low pressure sprinkler (on-board nozzle is considered part of sprinkler, not a separate item with additional incentive) New gooseneck as part of conversion to low pressure system 1. New regulator must be of same design pressure or less 1. New sprinkler is of same design flow or less 1. New sprinkler is of same design flow or less Gooseneck shall be used to convert existing center pivot with sprinkler equipment mounted on top of the pivot to low pressure sprinklers with regulators on new drop tubes. $3 each $3 each $1.50 each $0.50 per outlet (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

29 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 8b - Irrigation s Measures for Pivots and Linear Systems (Retrofit Only) (continued) Irrigation Measure Replace With Limitations Drop tube (3 ft minimum length) New center pivot base boot gasket replacing leaking base boot gasket New tower gasket replacing leaking tower gasket Leaking drop tube Leaking center pivot base boot gasket Leaking tower gasket New drop tube (3 ft minimum length) OR add drop tube as part of conversion to low pressure system New center pivot base boot gasket New tower gasket Drop tube or hose extension shall extend below the pivot lower brace or shall be a minimum of 3 ft in length, whichever is greater. 1. Gasket shall replace leaking gasket at the pivot point of the center pivot. 2. No more than one gasket shall be claimed per pivot. New gasket shall replace leaking tower gasket. $2 per drop tube $125 each $4 each Table 8c - Irrigation s Measures for Any Type of System (Retrofit or New Construction, Including Non-Agricultural Irrigation Applications) Irrigation Measure Replace With Limitations Irrigation pump VFD Add variable frequency drive to existing or new irrigation pump 1. Pumps serving any type of irrigation water transport or distribution system are eligible wheel lines, hand lines, pivots, linears, fixed-in-place (solid set). 2. Both retrofit and new construction projects are eligible. $0.15/kWh annual savings Notes for Irrigation Tables: 1. Equipment that meets or exceeds the requirements listed above may qualify for the listed incentive. 2. Except for the pump VFD measure, incentives listed here are available only for retrofit projects where new equipment replaces existing equipment (i.e. new construction is not eligible). 3. Except for the pump VFD measure, equipment installed in fixed-in-place (solid set) systems is not eligible. is limited to two units per irrigated acre. 4. s are capped at 70 percent of Energy Efficiency Costs, and incentives will not be available to reduce the Energy Efficiency Project simple payback below one year. Energy savings and Energy Efficiency Project Costs are subject to Company approval. VFD = Variable Frequency Drive (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

30 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Equipment Type Automatic Milker Takeoff (Retrofit Only) Table 9 Farm and Dairy Equipment s Equipment Category -- Minimum Efficiency Requirements Equipment must be able to sense milk flow and remove milker when flow reaches a pre-set level. The vacuum pump serving the affected milking units must be equipped with a VFD. is available for adding automatic milker takeoffs to existing milking systems, not for takeoffs on a brand new system where there were none before. Replacement of existing automatic milker takeoffs is not eligible for this listed incentive, but may qualify for a Custom Energy Efficiency incentive. $235 each Agricultural Engine Block Heater Timer High-efficiency Circulating fan (See Note 2) " Diameter 24-35" Diameter 36-47" Diameter 48" Diameter Heat Recovery -- High-efficiency Ventilation Fan (See Note 2) Milk Pre-cooler (Retrofit Only) 12-23" Diameter 24-35" Diameter 36-47" Diameter 48" Diameter -- Timer must be a UL-listed device and rated for a minimum of 15 amps continuous duty. Fan must achieve an efficiency level of 11 cfm/w Fan must achieve an efficiency level of 18 cfm/w Fans must achieve an efficiency level of 18 cfm/w Fans must achieve an efficiency level of 25 cfm/w Heat recovery unit must use heat rejected from milk cooling refrigeration system to heat water. Customer must use electricity for water heating. Fan must achieve an efficiency level of 11 cfm/w Fan must achieve an efficiency level of 13 cfm/w Fan must achieve an efficiency level of 17 cfm/w Fan must achieve an efficiency level of 19.5 cfm/w The equipment must cool milk with wellwater before it reaches the bulk cooling tank. New construction not eligible. $10 each $25/fan $35/fan $50/fan $75/fan $0.15/kWh annual energy savings $45/fan $75/fan $125/fan $150/fan $0.15/kWh annual energy savings (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

31 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Equipment Type Table 9 Farm and Dairy Equipment s (continued) Equipment Category Minimum Efficiency Requirements Programmable Ventilation Controllers -- The controller must control ventilation fans based on temperature or other applicable factors such as humidity, odor concentration, etc. $20/fan controlled Variable Frequency Drives for Dairy Vacuum Pumps (Retrofit Only) -- VFD must vary motor speed based on target vacuum level. available for retrofit only. New construction and replacement of existing VFD not eligible. $165/hp Notes for Table 9: 1. Equipment that meets or exceeds the efficiency requirements above may qualify for the listed incentive. 2. Fan performance must be rated by an independent testing body in accordance with the appropriate ANSI/AMCA standards. 3. s are capped at 70 percent of Energy Efficiency Project Costs and incentives will not be available to reduce Energy Efficiency Project simple payback below one year. Energy savings and Energy Efficiency Project Costs are subject to Company approval. 4. Except where noted, all equipment listed in the table is eligible for incentives in both new construction and retrofit projects. AMCA = Air Movement and Control Association International, Inc. ANSI = American National Standards Institute cfm = cubic feet per minute VFD = Variable Frequency Drive w = watt Table 10 Compressed Air s Equipment Category Replace With Limitations Unit Low Pressure drop filter where: 1.Pressure loss at rated flow is 1 psi when new and 3 psi at element change. 1. Compressor system must be 2. Particulate filtration is 25 hp and 75 hp. Standard Low Pressure 100% at 3.0 microns and 2. Compressor discharge pressure coalescing Drop Filter 99.98% at 0.1 to 3.0 setpoint must be reduced by 2 psi filter microns, with 5ppm or more after installation of low scfm liquid carryover. pressure drop filter. 3. Filter is of deep-bed mist eliminator style, with element life 5 years. 4. Rated capacity of filter is 500 scfm. $2/scfm (continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

32 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Equipment Category Receiver Capacity Addition Table 10 Compressed Air s (Continued) Replace With Limitations Unit Limited or no receiver capacity ( 2 gallons per scfm of trim compressor capacity) Total receiver capacity after addition must be > 2 gallons per scfm of trim compressor capacity 1. Compressor system size 75 horsepower, not counting backup compressor(s). 2. Trim compressor must use load/unload control, not inlet modulation or on/off control. 3. Systems with VFD compressor or using variable displacement compressor as trim compressor are not eligible. gal $3/gal above 2 gallons per scfm Cycling Refrigerated Dryer VFD Controlled Compressor Zero Loss Condensate Drain Outside Air Intake Compressed air end use reduction Non-cycling refrigerated dryer Fixed speed compressor Fixed timer drain Compressor drawing intake air from compressor room Inappropriate or inefficient compressed air end uses Cycling refrigerated dryer 75 hp VFD controlled oil-injected screw compressor operating in system with total compressor capacity 75 hp, not counting backup compressor capacity Zero loss condensate drain (See Note 4) Permanent ductwork between compressor air intake and outdoors. Functionally equivalent alternatives or isolation valves 1. Rated dryer capacity must be 500 scfm. 2. Dryer must operate exclusively in cycling mode and cannot be equipped with the ability to select between cycling and non-cycling mode. 3. Refrigeration compressor must cycle off during periods of reduced demand. 1. Total compressor capacity in upgraded system is 75 hp, not counting backup compressor. 2. Compressor must adjust speed as primary means of capacity control. Drain is designed to function without release of compressed air into the atmosphere. Any size system is eligible there is no restriction on compressor size. 1. Compressor system size 75 HP. 2. Ductwork must meet manufacturer's specifications, which may include: (a) 0.25" W.C. pressure loss at rated flow, and (b) allow use of compressor room air during extremely cold outside air conditions Any size system is eligible there is no restriction on compressor size. (continued) scfm each hp $2/scfm $0.15/kWh annual energy savings $100 each $6/hp $0.15/kWh annual energy savings Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

33 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Notes for Table 10: 1. Equipment that meets or exceeds the efficiency requirements above may qualify for the listed incentive. 2. Except for the zero loss condensate drain and compressed air end use reduction measures, eligibility for incentives is limited to compressed air systems with total compressor capacity of 75 hp or less, not including backup compressor capacity that does not normally run. 3. s are capped at 70 percent of Energy Efficiency Project Costs, and incentives will not be available to reduce Energy Efficiency Project simple payback below one year. Energy savings and Energy Efficiency Project Costs are subject to Company approval. 4. Zero loss condensate drains purchased as an integral part of another measure are eligible for the incentive shown above. hp = horsepower ppm = parts per million psi = pounds per square inch scfm = cubic feet of air per minute at standard conditions (14.5 psia, 68 F, and 0% relative humidity) VFD = variable frequency drive Table 11 - s for Wastewater, Oil and Gas, and Other Refrigeration Energy Efficiency Measures Equipment Type Replace With Conventional controls (defrost timeclock, space thermostat, evaporator fan control, if any, thermal expansion valve in some instances) Adaptive refrigeration control Fast acting door Manually operated door, automatic door with long cycle time, strip curtain, or entryway with no door in refrigerated/conditioned space Adaptive refrigeration controller and, in some instances, electric expansion valve Fast acting door $0.15/kWh annual energy savings $0.15/kWh annual energy savings Oil and gas pump off controller Add pump off controller to existing oil or gas well $1,500 per controller Wastewater low power mixer Excess aeration capacity Extended range circulator $0.15/kWh annual energy savings Notes for Table 11: 1. Equipment that meets or exceeds the efficiency requirements above may qualify for the listed incentive. 2. s are capped at 70 percent of Energy Efficiency Project Costs, and incentives will not be available to reduce the Energy Efficiency Project simple payback below one year. Energy savings and Energy Efficiency Project Costs are subject to Company approval. (continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

34 Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision of Sheet No Table 13 Mid-Market s 1 Measure Category Eligibility Requirements LED A-Lamp, Medium Base LED must be listed on qualified equipment list 2 $7/Lamp PAR Reflector Lamp LED must be listed on qualified equipment list $15/Lamp BR Reflector Lamp LED must be listed on qualified equipment list $13/Lamp MR16 Reflector Lamp LED must be listed on qualified equipment list $10/Lamp Candelabra/Globe Lamp Recessed Downlight Kit LED must be listed on qualified equipment list LED must be listed on qualified equipment list $10/Lamp $15/Fixture Tubular LED TLED LED must be listed on qualified equipment list $10/Lamp Notes for mid-market incentives: 1. s are capped at 70 percent of qualifying equipment cost. Qualifying equipment costs are subject to Company approval. 2. Qualified equipment lists referenced in the above table are posted on the Utah energy efficiency program section of the Company s website. 1 s for measures in this table are available through Company-approved retailers/distributors or a customer application process. 2 Actual incentives will be posted on the Company website and subject to change with 45 days notice. Change notices will be prominently displayed on program website and communicated to participating distributors and Trade Allies. Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 9, 2016 EFFECTIVE: March 10, 2016

35 Third Second Revision of Sheet No P.S.C.U. No. 50 Canceling SecondFirst Revision of Sheet No INCENTIVES: 1 Category Percent Project Cost Cap 1-Year Simple Payback Cap for Projects 2 Other Limitations Prescriptive s * See Tables 1a-11 See Tables 1a-11 See Tables 1a-11 See Tables 1a-11 Mid-market s Custom Non-Lighting s for qualifying measures not on the prescriptive list. 3 Energy Management Energy Project Manager Co-Funding Bill Credit 4 Determined by Company with not-toexceed amounts as shown in Table 13 $0.15 per annual kwh savings $0.02 per kwh annual savings $0.025 per kwh annual savings 80% of eligible project costs N/A No s available at the point of purchase through approved distributors/retailers or via a post-purchase customer application process 70% Yes N/A N/A No N/A 100% of salary and eligible overhead No 80% No Minimum 1,000,000 kwh through qualified measures Customers with minimum 1 MW peak or annual usage of 5,000,000 kwh** *s for measures contained in Tables 1a-11 are restricted to the amounts shown in Tables 1a-11 or the appropriate bill credit amount. **Customers may aggregate accounts to achieve minimum requirements. (Continued) 1 The customer or Owner may receive only one financial incentive from the Company per measure. Financial incentives include energy efficiency incentive payments, bill credits, and energy management payments. Energy Project Manager Co-Funding is available in addition to the project incentives. 2 The 1 year simple payback cap means incentives will not be available to reduce the simple payback of a project below one year. If required, individual measure incentives will be adjusted downward pro-rata so the project has a simple payback after incentives of one year. 3 Project Cost and 1-Year Simple Payback Caps do not apply to New Construction and Major Renovation projects that are subject to state energy code. 4 To qualify for the bill credit option, a project must have a projected payback period of between 1 and 8 years. The Company may accept a project with a projected payback period in excess of eight years if project benefits satisfy the Commission s approved costeffectiveness test. New Construction, lighting retrofits and Pre-payment projects are not eligible for bill credit. Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: May February 922, EFFECTIVE: July 1March 10, 20156

36 First Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision of Original Sheet No Table 1a - Retrofit Lighting Energy Efficiency Measures Measure Category Eligibility Requirements T8 Fluorescent CEE T8 Premium Delamp 4 CEE Qualified High Performance Lamp and CEE Qualified Ballast included on qualified list 4 CEE Qualified Reduced Wattage Lamp and CEE Qualified Ballast included on qualified list 4 CEE Qualified Reduced Wattage or High Performance Lamp and CEE Qualified Ballast. Must remove one or more lamps. To delamp an existing fixture, the lamp and all corresponding sockets must be permanently disabled. $3/Lamp $5/Lamp $21/Lamp Removed Relamp Lamp wattage reduction 3 Watts, No ballast retrofit $1/Lamp High Bay Continuous Operation Fixture with less than six (6) lamps: 4 CEE Qualified High Performance Lamp. Must replace T12HO/VHO, Incandescent, or HID. Fixture with six (6) or more lamps: 4 CEE Qualified High Performance Lamp. Must replace T12HO/VHO, Incandescent or HID 4 CEE Qualified Reduced Wattage or High Performance Lamp and CEE Qualified Ballast included on qualified list installed in a continuous operation application $18/Lamp $12/Lamp $20/Lamp Standard 4 Nominal Lamp 28 Watts, Ballast Factor 1.0 $5/Lamp T5 Fluorescent Relamp Lamp wattage reduction 3 Watts, No ballast retrofit $1/Lamp High Bay Continuous Operation Fixture with less than six (6) lamps: 4 T5HO Lamp. Must replace T12HO/VHO, Incandescent or HID. Fixture with six (6) or more lamps: 4 T5HO Lamp. Must replace T12HO/VHO, Incandescent or HID. 4' Nominal High Output Lamp installed in a continuous operation application $18/Lamp $12/Lamp $20/Lamp Cold Cathode Screw-in Lamp All wattages $5/Lamp Compact Fluorescent Lamp (CFL) Ceramic Metal Halide (CMH) Hardwired Fixture All wattages $5/Fixture CMH Fixture All wattages $35/Fixture PSMH Fixture Wattages > 500W $60/Fixture Pulse Start Metal Halide (PSMH) Electronic Must be used in place of or replace a magnetic ballast $20/Ballast Ballast Induction Induction Fixture All wattages, New fixtures only $75/Fixture LED LED LED must be listed on qualified equipment list $0.15/kWh annual energy savings Lighting Custom Not listed above $0.15/kWh annual energy savings Measure Category Eligibility Requirements Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: March 30February 9, EFFECTIVE: Marchy 1015, 20165

37 First Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision of Original Sheet No Interior Lighting Exterior Lighting Lighting Retrofits $0.15/kWh TLED Relamp Lamp wattage reduction of 10 Watts, No ballast or driver retrofit. $10/lamp Fluorescent Relamp Lighting Retrofits Street/Pole Lamp wattage reduction of 3 Watts, No ballast retrofit. $1/lamp $0.15/kWh $0.15/kWh Notes for Table 1a: 1. To be eligible for the incentives listed, the new lighting system must use less energy than the existing lighting system replaced or the baseline lighting system as determined by the Company. 2. s are capped at 70 percent of Energy Efficiency Project Costs and will not be available to reduce the Energy Efficiency Project simple payback below one year. Energy Efficiency Project costs are subject to Company approval. 3. s for TLED Fluorescent Relamps may not be combined with other lamp or fixture incentives and will only be paid once per facility. 4. Eligibale retrofit lighting equipment is defined in qualified equipment lists posted on the Utah energy efficiency program section of the Company s website. (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: March 30February 9, EFFECTIVE: Marchy 1015, 20165

38 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 1a - Retrofit Lighting Energy Efficiency Measures (Continued) Notes for Table 1a: 1. To be eligible for the incentives listed, the new lighting system must use less energy than the existing lighting system replaced or the baseline lighting system as determined by the Company. 2. s are capped at 70 percent of Energy Efficiency Project Costs and will not be available to reduce the Energy Efficiency Project simple payback below one year. Energy Efficiency Project costs are subject to Company approval. 3. s for T8 Fluorescent Premium Delamps may not be combined with other linear fluorescent lamp or fixture incentives. Complete fixture removals are not eligible. 4. s for T8 and T5 Fluorescent Relamps may not be combined with other linear fluorescent lamp or fixture incentives and will only be paid once per facility. 5. Qualified equipment lists referenced in the above table are posted on the Utah energy efficiency program section of the Company s website. BF = Ballast Factor CEE = Consortium for Energy Efficiency CFL = Compact Fluorescent Lamp CMH = Ceramic Metal Halide HID = High Intensity Discharge (e.g. Mercury Vapor, High Pressure Sodium, Metal Halide) HO = High Output LED = Light-Emitting Diode PSMH = Pulse-Start Metal Halide VHO = Very High Output Table 1b Lighting Controls and Non-General Illuminance s (Retrofit Only) Measure Category Eligibility Requirements Occupancy Control PIR, Dual Tech, or Integral Sensor $0.30/Watt controlled Interior Lighting Control Daylighting Control Advanced Daylighting Control Must control interior fixtures with Continuous, Stepped, or Bi-level ballast or automated control that dims 50% or more of the fixture in response to daylight. Must incorporate both an occupancy sensor and daylighting sensor operating as part of the same control sequence in the same interior space. $0.34/Watt controlled $0.38/Watt controlled Issued by authority of Report and Order of the Public Service Commission of Utah in Docket Advice No FILED: FebruarySeptember 95, , EFFECTIVE: September March

39 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Exterior Lighting Control Exterior Dimming Must control LED technology in an Control exterior lighting application. Control must be integral to LED fixture or fixturemounted and reduce fixture power by 75% or more for a minimum of 6 hrs per night or when the space has been unoccupied for 15 minutes or less. $0.34/Watt controlled (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Docket Advice No FILED: FebruarySeptember 95, , EFFECTIVE: September March

40 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 1b Lighting Controls and Non-General Illuminance s (Retrofit Only) (Continued) Measure Category Eligibility Requirements Non-General Illuminance Exit Sign LED Message Center Sign LED Channel Letter Sign LED Marquee/Cabinet Sign LED Case Lighting Reach-in Case LED Case Lighting Open Case Refrigerated Case Occupancy Sensor LED or photoluminescent replacing incandescent or fluorescent LED replacing existing incandescent signage LED replacing existing neon or fluorescent signage LED replacing existing fluorescent signage LED replacing fluorescent lamp in refrigerated cases. LED must be listed on qualified equipment list. Installed in existing refrigerated case with LED lighting Custom Custom Not listed above $15/Sign $5/Lamp $5/Linear Foot $5/Linear Foot $10/linear foot $10/linear foot $1/linear foot $0.15/kWh annual energy savings Notes for Table 1b: 1. To be eligible for the incentives listed, the new lighting system must use less energy than the existing lighting system replaced or the baseline lighting system as determined by the Company. 2. s are capped at 70 percent of Energy Efficiency Project Costs and incentives will not be available to reduce the Energy Efficiency Project simple payback below one year. Energy Efficiency Project Costs are subject to Company approval. 3. s for Advanced Daylighting Controls may not be combined with Occupancy Control or Daylighting Control incentives. 4. Watt controlled refers to the total wattage of lighting fixtures down circuit from the control. 5. Qualified equipment lists for measures referenced in the above table are posted on the Utah energy efficiency program section of the Company s website. PIR = Passive Infrared Dual Tech = Sensors combining ultrasonic and passive infrared LED - Light-emitting Diode (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Docket Advice No FILED: September February 95, , EFFECTIVE: September March

41 First Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision oforiginal Sheet No Table 1c New Construction/Major Renovation Lighting s Measure Category Eligibility Requirements Interior Lighting* Lighting and Lighting Control 1. The total connected interior lighting power for New Construction/Major Renovation projects must be at least 10% lower than the interior lighting power allowance calculated under the applicable version of the state energy code. For New Construction/Major Renovation projects not included in the state energy code, the total connected lighting power must be at least 10% lower than common practice as determined by the Company. 2. Energy savings is subject to approval by the Company $0.08/kWh annual energy savings Induction Fixture All Wattages, New Fixtures Only $75/Fixture LED Outdoor <75W; LED must be listed on qualified equipment Pole/Roadway, decorative list $75/Fixture 200W; LED must be listed on qualified equipment LED Outdoor list $100/fixture Pole/Roadway >200W; LED must be listed on qualified equipment list $400/fixture LED Canopy/Soffit LED must be listed on qualified equipment list $125/fixture LED Wall Packs <50 Watts; LED must be listed on qualified equipment list $50/fixture 50 Watts; LED must be listed on qualified equipment list $75/fixture Exterior Lighting LED Flood Lights <100 Watts; LED must be listed on qualified equipment list $75/fixture 100 Watts; LED must be listed on qualified equipment list $150/fixture CFL Wall Pack All Wattages, Hardwire Fixtures Only $30/Fixture Custom Not listed above $0.08/kWh annual energy savings Must control LED technology in an exterior lighting application. Control must be integral to LED fixture or fixture-mounted and reduce $0.34/Watt Exterior Dimming fixture power by 75% or more for a minimum ControlLighting Control controlled**$0.30/ of 6 hrs per night or when the space has been Watt controlled unoccupied for 15 minutes or less. eoccupancy control which must control a linear fluorescent, induction, or LED fixture *Project Cost Caps of 70% and 1-Year Simple Payback Caps apply to New Construction and Major Renovation projects that are not subject to state energy code. The 1 year simple payback cap means incentives will not be available to reduce the simple payback of a project below one year. If required, individual measure incentives will be adjusted downward pro-rata so the project has a simple payback after incentives of one year. ** Exterior lighting controls required by the applicable version of the state energy code are not eligible for incentives. CFL Compact Fluorescent Lamp Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 917, EFFECTIVE: March 1018, 20165

42 First Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision oforiginal Sheet No LED - Light-Emitting Diode (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: February 917, EFFECTIVE: March 1018, 20165

43 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 2 - Motor s Equipment Type Size Category Sub-Category Minimum Efficiency Requirement Customer Electronically 1 horsepower Refrigeration application -- $0.50/watt Commutated Motor (ECM) HVAC application -- $50/horsepower Variable-Frequency 100 horsepower HVAC fans and pumps See Note 2 $65/horsepower Drives (HVAC fans and pumps) Green Motor Rewinds 15 and 5,000 horsepower -- Must meet GMPG Standards $1/horsepower Refer to Note 3 Notes for Table 2: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. Throttling or bypass devices, such as inlet vanes, bypass dampers, three-way valves, or throttling valves must be removed or permanently disabled to qualify for HVAC fan or pump VFD incentives. VFDs required by or used to comply with the applicable version of the energy code are not eligible for incentives. Savings will only be realized for installations where a variable load is present. 3. For Green Motor Rewinds, the participating electric motor service center is paid $2/horsepower for eligible Green Motor Rewinds. A minimum of $1/horsepower is paid by the service center to the Customer as a credit on the motor rewind invoice. The balance is retained by the service center. Green Motor Rewind motors that are installed or placed in inventory may qualify for an incentive. ECM = Electronically Commutated Motor GMPG = Green Motors Practices Group HVAC = Heating, Ventilation and Air Conditioning NEMA = National Electrical Manufacturer s Association VFD = Variable Frequency Drive (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Docket Advice No FILED: September February 95, , EFFECTIVE: MarchSeptember

44 First Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision oforiginal Sheet No Table 3a HVAC s Minimum Efficiency Requirement & Customer Equipment Type Size Category Sub-Category $25/ton $50/ton $75/ton < 65, 000 Btu/hr Split system and Unitary Commercial (single phase) single package Air Conditioners, Air- -- CEE Tier 2 Cooled (Cooling Mode) -- CEE Tier 1 CEE Tier 2 Unitary Commercial Air Conditioners, Water and Evaporatively Cooled (See Note 8) Packaged Terminal Air Conditioners (PTAC) (Cooling Mode) Packaged Terminal Heat Pumps (PTHP) (Heating & Cooling Mode) Heat Pumps, Air- Cooled (Cooling Mode) Heat Pumps, Air- Cooled (Heating Mode) - See Note 3 Heat Pumps, Water- Source (Cooling Mode) All equipment sizes (three phase) All equipment sizes Split system and single package Split system and single package -- CEE Tier ,000 Btu/hr Single package 12.2 EER > 8,000 Btu/hr and < 10,500 Btu/hr Single package 11.9 EER ,500 Btu/hr and 13,500 Single package 10.7 EER Btu/hr > 13,500 Btu/hr Single package 9.9 EER ,000 Btu/hr Single package EER and 3.4 COP -- > 8,000 Btu/hr and 11.5 EER and 3.3 Single package -- < 10,500 Btu/hr COP -- 10,500 Btu/hr 10.7 EER and 3.1 and 13,500 Single package -- COP Btu/hr -- > 13,500 Btu/hr Single package EER and 3.0 COP -- < 65, 000 Btu/hr Split system and (single phase) single package -- CEE Tier 2 < 65, 000 Btu/hr Split system and -- CEE Tier 2 (three phase) single package CEE Tier 1 65,000 Btu/hr Split system and (three phase) single package < 65, 000 Btu/hr Split system and (single phase) single package -- CEE Tier 2 < 65, 000 Btu/hr Split system and (three phase) single package -- CEE Tier 2 65,000 Btu/hr (three phase) 47 F db/43 F wb outdoor air 17 F db/15 F wb outdoor air -- CEE Tier < 135,000 Btu/hr 86 F Entering Water -- CEE Tier 1 -- (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: March February 930, EFFECTIVE: Marchy 1015, 20156

45 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 3a HVAC s (Continued) Minimum Efficiency Requirement & Customer Equipment Type Size Category Sub-Category $25/ton $50/ton $75/ton Heat Pumps, Water- Source (Heating Mode) - See Note 3 < 135,000 Btu/hr 68 F Entering Water -- CEE Tier 1 -- VRF Air-Cooled Heat Pumps (Cooling Mode) VRF Air-Cooled Heat Pumps (Heating Mode) VRF Water-Cooled Heat Pumps (Cooling Mode) VRF Water-Cooled Heat Pumps (Heating Mode) Heat Pumps, Ground- Source or Groundwater-Source (Heating & Cooling Mode) - See Note 3 All Equipment Sizes All Equipment Sizes < 135,000 Btu/hr < 135,000 Btu/hr Multisplit System or Multisplit System with Heat Recovery Multisplit System or Multisplit System with Heat Recovery (See note 3) Multisplit System or Multisplit System with Heat Recovery Multisplit System or Multisplit System with Heat Recovery (See note 3) 77 F Entering Water -- CEE Tier 1 CEE Tier 1 CEE Tier 1 CEE Tier 1 ENERGY STAR Qualified -- All sizes Ground Source or Groundwater-Source Heat Pump Loop All sizes $25/ton Notes for table 3a - HVAC equipment incentive table 1. Equipment that meets or exceeds the efficiency requirements listed for the size category in the above table may qualify for the listed incentive. Equipment must meet all listed efficiency requirements to qualify for the listed incentives. 2. PTHPs can replace electric resistive heating, which must be removed. 3. s for heat pumps are available per ton of cooling capacity ONLY. No incentives are paid per ton of heating capacity. Heat Pumps must meet both the cooling mode and heating mode efficiency requirements to qualify for per ton cooling efficiency incentives. 4. Equipment size categories and capacities are specified in terms of net cooling capacity at AHRI standard conditions as determined by AHRI Standard 210/240 for units <65,000 Btu/hr, AHRI Standard 340/360 for units 65,000 Btu/hr, AHRI Standard 310/380 for PTAC and PTHP units, and AHRI Standard 1230 for VRF systems. 5. Ground and Water Source Heat Pumps must meet or exceed listed efficiency requirements when rated in accordance with ISO to qualify for the listed incentive. 6. Units rated with an IPLV may qualify for the listed incentives if the value meets or exceeds the minimum IPLV established in the Consortium for Energy Efficiency Commercial Unitary Air Conditioning and Heat Pump specification effective January 16, Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: September March1

46 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Efficiency requirements align with the Unitary Air-Conditioning and Heat Pump Specification maintained by the Consortium for Energy Efficiency for equipment with heating sections other than electric resistance. CEE minimum efficiency requirements are listed on the Company website. (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: September March1

47 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Notes for table 3a - HVAC equipment incentive table (continued) AHRI = Air-Conditioning, Heating, and Refrigeration Institute IEER = Integrated Energy Efficiency Ratio CEE = Consortium for Energy Efficiency IPLV = Integrated Part Load Value COP = Coefficient of Performance PTAC = Packaged Terminal Air Conditioner EER = Energy Efficiency Ratio PTHP = Packaged Terminal Heat Pump HSPF = Heating Seasonal Performance Factor SEER = Seasonal Energy Efficiency Ratio HVAC = Heating, Ventilation and Air-Conditioning VFR = Variable Refrigerant Flow Table 3b Other HVAC s Equipment Type Size Category Sub-Category Minimum Efficiency Requirement Customer Evaporative Cooling All sizes Direct or Indirect $0.06/ CFM Indirect-Direct Evaporative Cooling (IDEC) Chillers Room Air Conditioner 365/366 day Programmable or Occupancy-based Thermostat Occupancy Based PTHP/PTAC control Evaporative Pre-cooler (Retrofit Only) All sizes -- Applicable system components must exceed minimum efficiencies required by energy code All except chillers intended for backup service only Residential (used in a business) All sizes in portable classrooms with mechanical cooling All sizes with no prior occupancy based control Serving primarily occupant comfort cooling loads (no more than 20% for process cooling loads) See Home Energy Savings program Must be installed in portable classroom unoccupied during summer months For single aircooled packaged rooftop or matched split system condensers only Must exceed minimum efficiencies required by energy code See Home Energy Savings program 365/366 day thermostatic or occupancy based setback capability See Note 5 Minimum performance efficiency of 75%. Must have enthalpy controls to control pre-cooler operation. Water supply must have chemical or mechanical water treatment. $0.15/kWh annual energy savings See Note 2 $0.15/kWh annual energy savings See Note 3 See Note 4 $150/thermostat $50/controller $75/ton of attached cooling capacity (See Note 5) Notes for Table 3b 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. s paid at $0.15/kWh annual energy savings. IDEC energy savings subject to approval by the Company. 3. s paid at $0.15/kWh annual energy savings. Chiller energy savings subject to approval by the Company. 4. Refer to Company's Home Energy Savings program for efficiency requirements and incentives for listed residential equipment used in a business. 4. Controller units must include an occupancy based control and include the capability to set back the zone temperature during extended unoccupied periods and set up the temperature once the zone is occupied. 5. s for Evaporative Pre-coolers are capped at 70 percent of Energy Efficiency Project Costs and incentives will not be available to reduce the Energy Efficiency Project simple payback below one year. 6. Energy Efficiency Project Costs are subject to Rocky Mountain Power approval Issued by authority of Report and Order of the Public Service Commission of Utah in Docket Advice No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

48 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No CFM = Cubic Feet per Minute HVAC = Heating, Ventilating and Air Conditioning IDEC = Indirect Direct Evaporative Cooling PTAC = Packaged Terminal Air Conditioner PTHP = Packaged Terminal Heat Pump (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Docket Advice No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

49 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 4a Building Envelope s (Retrofit) Equipment Type Category Minimum Efficiency Requirement Cool Roof -- ENERGY STAR Qualified Roof/Attic Insulation -- Wall Insulation -- Windows (See Note 3, 4) Site-Built Assembly Minimum increment of R-10 insulation added Minimum increment of R-10 insulation added U-Factor 0.30 and SHGC 0.33 (Glazing Only Rating) U-Factor 0.30 and SHGC 0.33 (Entire Window Assembly Rating) Window Film Existing Windows See Note 5 Customer $0.10/square foot $0.05/square foot $0.07/square foot $0.35/square foot $0.35/square foot $0.15/kWh annual energy savings (See Note 5) Notes for Table 4a: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. Building must be conditioned with mechanical cooling to be eligible for envelope incentives. 3. Energy performance of window assemblies and glazing products must be rated in accordance with NFRC. Site-Built metal window systems must include a thermal break within the frame or other appropriate NFRC certification to qualify for incentives. Skylights are not eligible to receive the incentives in the above table. 4. Window square footage is determined by the dimensions of the entire window assembly, not just the window glass. 5. s for window film are calculated based on film specifications and window orientation at $0.15/kWh annual energy savings. Energy savings are subject to approval by the Company. NFRC = National Fenestration Rating Council SHGC = Solar Heat Gain Coefficient Table 4b Building Envelope s (New Construction/Major Renovation) Customer Equipment Type Category Minimum Efficiency Requirement Cool Roof -- ENERGY STAR Qualified Roof/Attic Insulation -- Wall Insulation -- Windows (See Note 3, 4) Site-Built Minimum increment of R-5 insulation above code (See Note 5) Minimum increment of R-3.7 continuous insulation above code (See Note 5) U-Factor 0.30 and SHGC 0.33 (Glazing Only Rating) $0.10/square foot $0.05/square foot $0.07/square foot $0.35/square foot Issued by authority of Report and Order of the Public Service Commission of Utah in Docket Advice No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

50 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Assembly U-Factor 0.30 and SHGC 0.33 (Entire Window Assembly Rating) (Continued) $0.35/square foot Issued by authority of Report and Order of the Public Service Commission of Utah in Docket Advice No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

51 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 5 Food Service Equipment s Equipment Type Equipment Category Minimum Efficiency Requirement Customer /Unit Residential Dishwasher Used in a Business See Home Energy Savings Program See Note 2 Undercounter $100 Commercial Dishwasher (High Temperature models w/ electric boosters only) Electric Insulated Holding Cabinet Electric Steam Cooker Stationary Rack, Single Tank, Door Type ENERGY STAR Qualified $400 Single Tank Conveyor $1,000 Multiple Tank Conveyor $500 V 28 $ V < 28 ENERGY STAR Qualified $300 V < 13 $200 3-, 4-, 5- and 6-pan or larger sizes - Tier 1 ENERGY STAR Qualified $130 3-, 4-, 5- and 6-pan or larger sizes - Tier 2 ENERGY STAR Qualified w/ Heavy Load Efficiency 68% Electric Convection Oven -- ENERGY STAR Qualified $350 Electric Griddle ENERGY STAR Tier 2 Qualified $150 $300 Electric Combination Oven 6-14 pans ENERGY STAR Qualified $1, pans ENERGY STAR Qualified $275 Tier 1 ENERGY STAR Qualified $200 Electric Commercial Fryer ENERGY STAR Qualified w/cooking Tier 2 Efficiency 85%, Idle Energy Rate 860 $300 Watts Tier 1: Harvest Rate < 500 $125 lbs/day ENERGY STAR Qualified Tier 1: Harvest Rate 500 $150 Ice Machines lbs/day (Air-Cooled Only) Tier 2: Harvest Rate < 500 $250 lbs/day CEE Tier 2 Qualified Tier 2: Harvest Rate 500 $400 lbs/day Residential Refrigerator Used in a Business See Home Energy Savings Program See Note 2 Residential Refrigerator/ Freezer Recycling Used in a business See residential refrigerator/ freezer recycling program See Note 4 (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

52 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Commercial Transparent Door Refrigerator (See Note 3) Commercial Transparent Door Freezer (See Note 3) LED Case Lighting (Retrofit Only) Refrigerated Case Occupancy Sensor (Retrofit Only) Demand Controlled Kitchen Ventilation Exhaust Hood (Retrofit Only) Anti-Sweat Heater Controls (Retrofit Only) Table 5 Food Service Equipment s (Continued) 0 < V < V < 30 $50 30 V < 50 ENERGY STAR Qualified $75 50 V $125 Chest Configuration $50 0 < V < V < 30 $50 30 V < 50 ENERGY STAR Qualified $75 50 V $100 Chest Configuration $ Must be installed on commercial kitchen exhaust system. Low-Temp (Freezing) Cases Med-Temp (Refrigerated) Cases LED replacing fluorescent lighting in refrigerated cases. Installed in existing refrigerated case with LED lighting Variable speed motors must be controlled to vary fan speed depending upon kitchen demand, as indicated by connected sensors. Controls that reduce energy consumption of anti-sweat heaters based on sensing humidity. $25 $25 $10/linear foot $1/linear foot $0.15/kWh annual energy savings (See note 5) $20/linear foot (case length) $16/linear foot (case length) Notes for Table 5: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. Refer to Company's Home Energy Savings program for efficiency requirements and incentives for listed residential appliances used in a business. 3. To meet the Minimum Efficiency Requirement(s) listed, values must be based on testing in accordance with the applicable ASTM Standard Test Method. 4. Refer to the Company s residential refrigerator and freezer recycling program for requirements and incentives for listed appliance recycling measures for residential appliances used in a business. 52. s are paid at $0.15/kWh annual energy savings. Demand controlled kitchen ventilation exhaust hood energy savings subject to approval by Company. 3. s for commercial refrigerators and freezers will no longer be available effective March 27, CEE = Consortium for Energy Efficiency ASTM = American Society for Testing and Materials MDEC = Maximum Daily Energy Consumption Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

53 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No V = Association of Home Appliance Manufacturers (AHAM) Volume (cubic feet) (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

54 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Equipment Type Network PC Power Management Software Table 6 Office Equipment s Minimum Efficiency Requirements 1. Installed software must automatically control the power settings of networked personal computers (PC) at the server level 2. The software must manage power consumption for each individual PC 3. The software must include the capability to report energy savings results 4. s are for desktop computers only. Controlled laptop computers are not eligible for incentives Customer $5 per controlled PC Smart Plug Strip 1. applies to any plug strip that eliminates idle or stand-by power consumption of connected plug-load appliance through the use of an occupancy sensor, electric load sensor, or timer. 2. Applies only to electric plug-load applications (e.g. computer monitors, desk lamps, etc.) $15/qualifying unit Notes for Table 6: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. PC = Personal Computer (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in Docket Advice No FILED: FebruarySeptember 59, , EFFECTIVE: MarchSeptember

55 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Equipment Type High-Efficiency Clothes Washer Heat Pump Water HeaterElectric Water Heater Table 7 Appliance s Equipment Category Residential (used in a business) Commercial (must have electric water heating) Residential (used in a business)residential (used in a business) Minimum Efficiency Requirement Customer See Home Energy Savings Program See Note 3 ENERGY STAR Qualified $100 See Home Energy Savings ProgramSee Home Energy Savings Program See Note 3 Notes for Table 7: 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. 2. Equipment must meet the efficiency rating standard that is in effect on the date of purchase. 3. Refer to Company's Home Energy Savings program for efficiency requirements and incentives for listed residential appliances used in a business. (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

56 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 8a - Irrigation s - Measures for Wheel Line, Hand Line, or Other Portable Systems (Retrofit Only) Irrigation Measure Replace With Limitations Leaking or malfunctioning impact or rotating Rotating sprinkler sprinkler irrigated acre. New rotating sprinkler replacing worn or leaking impact or rotating sprinkler New or rebuilt impact sprinkler replacing worn or leaking impact sprinkler New nozzle replacing worn nozzle of same design flow or less on existing sprinkler New flow-control nozzle for impact sprinkler replacing existing nozzle or worn flow-control nozzle of same design flow or less New gasket replacing leaking gasket, including mainline valve or section gasket, seal, or riser cap (dome disc) New drain replacing leaking drain Cut and press or weld repair of leaking wheel line, hand line, or portable main line Leaking or malfunctioning impact sprinkler Worn nozzle Worn nozzle Leaking gasket Leaking drain Leak in wheel line, hand line, or portable main line New or rebuilt impact sprinkler New nozzle of same design flow or less New flow control nozzle New gasket, including mainline valve or section gasket, seal, or riser cap (dome disc) New drain, including drains on pivots and linears Cut and pipe press or weld repair 1. Fixed-in-place (solid set) systems not eligible. 2. limited to two sprinklers per 1. New nozzle shall be included in new or rebuilt sprinkler. Rebuilt sprinkler shall meet or exceed manufacturer s specifications. 2. Fixed-in-place (solid set) systems not eligible. 3. limited to two sprinklers per irrigated acre. 1. Flow rate shall not be increased. 2. All nozzles on the wheel line or hand line shall be replaced. 3. Fixed-in-place (solid set) systems not eligible. 4. limited to two nozzles per irrigated acre. 1. Nozzle to be replaced may be fixed orifice or flow control type. 2. New flow control nozzle shall have a flow rating equal to or less than the flow rating of the existing nozzles at 40 psi. 3. All nozzles on the wheel line or hand line shall be replaced. 4. Fixed-in-place (solid set) systems not eligible. 5. limited to two nozzles per irrigated acre. 1. New gasket must replace leaking gasket. 2. Fixed-in-place (solid set) systems not eligible. 3. limited to two gaskets per irrigated acre. 1. New drain must replace leaking drain. 2. Fixed-in-place (solid set) systems not eligible. 3. limited to two drains per irrigated acre. 1. For rebuilds, invoice must show number of rebuild kits purchased and installed. Customer $2.50 each $2.25 each $0.50 each $2.75 each $2 each $3 each $10/repair Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

57 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No New or rebuilt wheel line leveler replacing leaking or malfunctioning leveler Leaking or malfunctioning leveler New or rebuilt leveler (Continued) 1. Applies to leaking or malfunctioning levelers only. 2. For rebuilds, invoice must show number of rebuild kits purchased and installed. $3 each Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

58 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 8a - Irrigation s Measures for Wheel Line, hand Line, or Other Portable Systems (Retrofit Only) (Continued) Irrigation Measure Replace With Limitations New or rebuilt wheel line feed hose replacing leaking wheel line feed hose New Thunderbird wheel line hub replacing leaking wheel line hub Leaking wheel line feed hose Leaking Thunderbird wheel line hub New or rebuilt wheel line feed hose New Thunderbird wheel line hub 1. Applies to leaking wheel line feed hose only. 2. For rebuilds, invoice must show number of rebuild kits purchased and installed. New hub must replace leaking hub Table 8b - Irrigation s Measures for Pivots and Linear Systems (Retrofit Only) Irrigation Measure Replace With Limitations Pressure regulator Low pressure sprinkler (e.g. rotating, wobbling, multi-trajectory spray) replacing impact sprinkler Low pressure sprinkler (e.g. rotating, wobbling, multi-trajectory spray) replacing worn low pressure sprinkler Gooseneck as part of conversion to low pressure system Worn pressure regulator Impact sprinkler Worn low pressure sprinkler (e.g. rotating, wobbling, multi-trajectory spray) New pressure regulator of same design pressure or less New low pressure sprinkler (on-board nozzle is considered part of sprinkler, not a separate item with additional incentive) New low pressure sprinkler (on-board nozzle is considered part of sprinkler, not a separate item with additional incentive) New gooseneck as part of conversion to low pressure system 1. New regulator must be of same design pressure or less 1. New sprinkler is of same design flow or less 1. New sprinkler is of same design flow or less Gooseneck shall be used to convert existing center pivot with sprinkler equipment mounted on top of the pivot to low pressure sprinklers with regulators on new drop tubes. Customer $12 each $10 each Customer $3 each $3 each $1.50 each $0.50 per outlet (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

59 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Table 8b - Irrigation s Measures for Pivots and Linear Systems (Retrofit Only) (continued) Irrigation Measure Replace With Limitations Drop tube (3 ft minimum length) New center pivot base boot gasket replacing leaking base boot gasket New tower gasket replacing leaking tower gasket Leaking drop tube Leaking center pivot base boot gasket Leaking tower gasket New drop tube (3 ft minimum length) OR add drop tube as part of conversion to low pressure system New center pivot base boot gasket New tower gasket Drop tube or hose extension shall extend below the pivot lower brace or shall be a minimum of 3 ft in length, whichever is greater. 1. Gasket shall replace leaking gasket at the pivot point of the center pivot. 2. No more than one gasket shall be claimed per pivot. New gasket shall replace leaking tower gasket. Customer $2 per drop tube $125 each $4 each Table 8c - Irrigation s Measures for Any Type of System (Retrofit or New Construction, Including Non-Agricultural Irrigation Applications) Irrigation Measure Replace With Limitations Irrigation pump VFD Add variable frequency drive to existing or new irrigation pump 1. Pumps serving any type of irrigation water transport or distribution system are eligible wheel lines, hand lines, pivots, linears, fixed-in-place (solid set). 2. Both retrofit and new construction projects are eligible. Customer $0.15/kWh annual savings Notes for Irrigation Tables: 1. Equipment that meets or exceeds the requirements listed above may qualify for the listed incentive. 2. Except for the pump VFD measure, incentives listed here are available only for retrofit projects where new equipment replaces existing equipment (i.e. new construction is not eligible). 3. Except for the pump VFD measure, equipment installed in fixed-in-place (solid set) systems is not eligible. is limited to two units per irrigated acre. 4. s are capped at 70 percent of Energy Efficiency Costs, and incentives will not be available to reduce the Energy Efficiency Project simple payback below one year. Energy savings and Energy Efficiency Project Costs are subject to Company approval. VFD = Variable Frequency Drive (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

60 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Equipment Type Automatic Milker Takeoff (Retrofit Only) Table 9 Farm and Dairy Equipment s Equipment Category -- Minimum Efficiency Requirements Equipment must be able to sense milk flow and remove milker when flow reaches a pre-set level. The vacuum pump serving the affected milking units must be equipped with a VFD. is available for adding automatic milker takeoffs to existing milking systems, not for takeoffs on a brand new system where there were none before. Replacement of existing automatic milker takeoffs is not eligible for this listed incentive, but may qualify for a Custom Energy Efficiency incentive. Customer $235 each Agricultural Engine Block Heater Timer High-efficiency Circulating fan (See Note 2) " Diameter 24-35" Diameter 36-47" Diameter 48" Diameter Heat Recovery -- High-efficiency Ventilation Fan (See Note 2) Milk Pre-cooler (Retrofit Only) 12-23" Diameter 24-35" Diameter 36-47" Diameter 48" Diameter -- Timer must be a UL-listed device and rated for a minimum of 15 amps continuous duty. Fan must achieve an efficiency level of 11 cfm/w Fan must achieve an efficiency level of 18 cfm/w Fans must achieve an efficiency level of 18 cfm/w Fans must achieve an efficiency level of 25 cfm/w Heat recovery unit must use heat rejected from milk cooling refrigeration system to heat water. Customer must use electricity for water heating. Fan must achieve an efficiency level of 11 cfm/w Fan must achieve an efficiency level of 13 cfm/w Fan must achieve an efficiency level of 17 cfm/w Fan must achieve an efficiency level of 19.5 cfm/w The equipment must cool milk with wellwater before it reaches the bulk cooling tank. New construction not eligible. $10 each $25/fan $35/fan $50/fan $75/fan $0.15/kWh annual energy savings $45/fan $75/fan $125/fan $150/fan $0.15/kWh annual energy savings Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: March September

61 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No (Continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: March September

62 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Equipment Type Programmable Ventilation Controllers Variable Frequency Drives for Dairy Vacuum Pumps (Retrofit Only) Table 9 Farm and Dairy Equipment s (continued) Equipment Category Minimum Efficiency Requirements The controller must control ventilation fans based on temperature or other applicable factors such as humidity, odor concentration, etc. VFD must vary motor speed based on target vacuum level. available for retrofit only. New construction and replacement of existing VFD not eligible. Customer $20/fan controlled $165/hp Notes for Table 9: 1. Equipment that meets or exceeds the efficiency requirements above may qualify for the listed incentive. 2. Fan performance must be rated by an independent testing body in accordance with the appropriate ANSI/AMCA standards. 3. s are capped at 70 percent of Energy Efficiency Project Costs and incentives will not be available to reduce Energy Efficiency Project simple payback below one year. Energy savings and Energy Efficiency Project Costs are subject to Company approval. 4. Except where noted, all equipment listed in the table is eligible for incentives in both new construction and retrofit projects. AMCA = Air Movement and Control Association International, Inc. ANSI = American National Standards Institute cfm = cubic feet per minute VFD = Variable Frequency Drive w = watt Table 10 Compressed Air s Equipment Category Replace With Limitations Unit Low Pressure drop filter where: 1.Pressure loss at rated flow is 1 psi when new and 3 psi at element 1. Compressor system must be change. 25 hp and 75 hp. Standard 2. Particulate filtration is Low Pressure 2. Compressor discharge pressure coalescing 100% at 3.0 microns and Drop Filter setpoint must be reduced by 2 psi filter 99.98% at 0.1 to 3.0 or more after installation of low microns, with 5ppm pressure drop filter. liquid carryover. scfm 3. Filter is of deep-bed mist eliminator style, with element life 5 years. 4. Rated capacity of filter Customer $2/scfm Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

63 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No is 500 scfm. (continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

64 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Equipment Category Receiver Capacity Addition Table 10 Compressed Air s (Continued) Replace With Limitations Unit Limited or no receiver capacity ( 2 gallons per scfm of trim compressor capacity) Total receiver capacity after addition must be > 2 gallons per scfm of trim compressor capacity 1. Compressor system size 75 horsepower, not counting backup compressor(s). 2. Trim compressor must use load/unload control, not inlet modulation or on/off control. 3. Systems with VFD compressor or using variable displacement compressor as trim compressor are not eligible. gal Customer $3/gal above 2 gallons per scfm Cycling Refrigerated Dryer VFD Controlled Compressor Zero Loss Condensate Drain Outside Air Intake Compressed air end use reduction Non-cycling refrigerated dryer Fixed speed compressor Fixed timer drain Compressor drawing intake air from compressor room Inappropriate or inefficient compressed air end uses Cycling refrigerated dryer 75 hp VFD controlled oil-injected screw compressor operating in system with total compressor capacity 75 hp, not counting backup compressor capacity Zero loss condensate drain (See Note 4) Permanent ductwork between compressor air intake and outdoors. Functionally equivalent alternatives or isolation valves 1. Rated dryer capacity must be 500 scfm. 2. Dryer must operate exclusively in cycling mode and cannot be equipped with the ability to select between cycling and non-cycling mode. 3. Refrigeration compressor must cycle off during periods of reduced demand. 1. Total compressor capacity in upgraded system is 75 hp, not counting backup compressor. 2. Compressor must adjust speed as primary means of capacity control. Drain is designed to function without release of compressed air into the atmosphere. Any size system is eligible there is no restriction on compressor size. 1. Compressor system size 75 HP. 2. Ductwork must meet manufacturer's specifications, which may include: (a) 0.25" W.C. pressure loss at rated flow, and (b) allow use of compressor room air during extremely cold outside air conditions Any size system is eligible there is no restriction on compressor size. scfm each hp $2/scfm $0.15/kWh annual energy savings $100 each $6/hp $0.15/kWh annual energy savings Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

65 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No (continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

66 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No Notes for Table 10: 1. Equipment that meets or exceeds the efficiency requirements above may qualify for the listed incentive. 2. Except for the zero loss condensate drain and compressed air end use reduction measures, eligibility for incentives is limited to compressed air systems with total compressor capacity of 75 hp or less, not including backup compressor capacity that does not normally run. 3. s are capped at 70 percent of Energy Efficiency Project Costs, and incentives will not be available to reduce Energy Efficiency Project simple payback below one year. Energy savings and Energy Efficiency Project Costs are subject to Company approval. 4. Zero loss condensate drains purchased as an integral part of another measure are eligible for the incentive shown above. hp = horsepower ppm = parts per million psi = pounds per square inch scfm = cubic feet of air per minute at standard conditions (14.5 psia, 68 F, and 0% relative humidity) VFD = variable frequency drive Table 11 - s for Wastewater, Oil and Gas, and Other Refrigeration Energy Efficiency Measures Equipment Type Replace With Conventional controls (defrost timeclock, space thermostat, evaporator fan control, if any, thermal expansion valve in some instances) Adaptive refrigeration control Fast acting door Manually operated door, automatic door with long cycle time, strip curtain, or entryway with no door in refrigerated/conditioned space Adaptive refrigeration controller and, in some instances, electric expansion valve Fast acting door Customer $0.15/kWh annual energy savings $0.15/kWh annual energy savings Oil and gas pump off controller Add pump off controller to existing oil or gas well $1,500 per controller Wastewater low power mixer Excess aeration capacity Extended range circulator $0.15/kWh annual energy savings Notes for Table 11: 1. Equipment that meets or exceeds the efficiency requirements above may qualify for the listed incentive. 2. s are capped at 70 percent of Energy Efficiency Project Costs, and incentives will not be available to reduce the Energy Efficiency Project simple payback below one year. Energy savings and Energy Efficiency Project Costs are subject to Company approval. Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

67 First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No (continued) Issued by authority of Report and Order of the Public Service Commission of Utah in AdviceDocket No FILED: FebruarySeptember 95, , EFFECTIVE: MarchSeptember

68 First Second Revision of Sheet No P.S.C.U. No. 50 Canceling First Revision oforiginal Sheet No Table 13 Mid-Market s 1 Measure Category Eligibility Requirements LED Screw-in A-Lamp, Medium Base Screw-in PAR Reflector Lamp Screw-in BR Reflector Lamp Pin-based MR16 Reflector Lamp Screw-in Candelabra/Globe Lamp Recessed Downlight Kit LED must be listed on qualified equipment list LED must be listed on qualified equipment list LED must be listed on qualified equipment list LED must be listed on qualified equipment list LED must be listed on qualified equipment list LED must be listed on qualified equipment list Maximum 2 Up to $7/Lamp Up to $15/Lamp Up to $13/Lamp Up to $10/Lamp Up to $10/Lamp Up to $15/Fixture Tubular LED TLED LED must be listed on qualified equipment list $10/Lamp Notes for mid-market incentives: 1. s are capped at 70 percent of qualifying equipment cost. Qualifying equipment costs are subject to Company approval. 2. Qualified equipment lists referenced in the above table are posted on the Utah energy efficiency program section of the Company s website. 1 s for measures in this table are available through Company-approved retailers/distributors or a customer application process. 2 Actual incentives will be posted on the Company website and subject to change with 45 days notice. Change notices will be prominently displayed on program website and communicated to participating distributors and Trade Allies. Issued by authority of Report and Order of the Public Service Commission of Utah in Advice No FILED: FebruaryJuly 914, EFFECTIVE: MarchAugust 1013, 20165

69 EXHIBIT B

70 MEMORANDUM To: Eli Morris From: Brian Hedman and Byron Boyle Subject: UT Wattsmart Business Cost Effectiveness Date: January 25, 2016 The tables below present the cost effectiveness findings for the Wattsmart Business program, based on costs and savings estimates provided by PacifiCorp in the spreadsheet entitled UT WSB C E Inputs xlsx ; and in an from Eli Morris on January 20, The utility discount rate is from the 2015 PacifiCorp Integrated Resource Plan. For all scenarios, cost effectiveness was tested using the 2015 IRP East Industrial 40%, East Commercial Lighting 53%, East Commercial Cooling 14%, and East Plug Load 71% Load Factor Decrements. Table 1 lists modeling inputs. Table 2 list the costs and incentives and

71 Table 3 lists the annual energy savings for each program and scenario. Table 4 provides a comparative summary of the benefit/cost ratios from all five test perspectives by scenario. Table 7 to Table 12 show the complete cost effectiveness results for each scenario. All scenarios are cost effective from all test perspectives except the RIM. Table UT Wattsmart Business Program Financial Inputs Parameter Value Discount Rate 6.66% Commercial Line Loss 8.71% Industrial Line Loss 5.85% Commercial Energy Rate ($/kwh) 2014 base rate $ Industrial Energy Rate ($/kwh) 2014 base rate $ Inflation Rate 1.9% Table Wattsmart Business Program Costs Measure Year Admin Delivery s Business as Usual Proposed with Changes Proposed with Changes +10% Participation Proposed with Changes 10% Participation Lighting Only Business as Usual Lighting Only with Proposed Changes Lighting Only with Proposed Changes +10% Participation Lighting Only with Proposed Changes 10% Participation Total Utility Costs Participant Incremental Cost $1,600,000 $15,639,746 $62,883,463 $80,123,208 $146,429,541 $1,600,000 $15,639,746 $50,290,840 $67,530,585 $138,505,053 $1,600,000 $17,203,720 $55,319,924 $74,123,644 $152,355,559 $1,600,000 $14,075,771 $45,261,756 $60,937,527 $124,654,548 $400,000 $4,811,285 $29,344,849 $34,556,134 $71,333,845 $400,000 $4,811,285 $16,772,904 $21,984,189 $63,458,651 $400,000 $5,292,413 $18,450,195 $24,142,608 $69,804,516 $400,000 $4,330,156 $15,095,614 $19,825,770 $57,112,786 2

72 Measure Business as Usual Proposed with Changes Proposed with Changes +10% Participation Proposed with Changes 10% Participation Lighting Only Business as Usual Lighting Only with Proposed Changes Lighting Only with Proposed Changes +10% Participation Lighting Only with Proposed Changes 10% Participation Table UT Wattsmart Business Program Annual Savings Year Gross KWh Savings Realization Rate Adjusted KWh Savings Net to Gross Percentage Net KWh Savings Measure Life 451,861,903 95% 428,470,236 86% 369,433, ,457,930 95% 409,848,779 87% 354,849, ,503,723 95% 450,833,657 87% 390,334, ,412,137 95% 368,863,901 87% 319,364, ,919,492 88% 159,804,959 80% 128,206, ,937,059 89% 141,550,242 80% 113,789, ,930,765 89% 155,705,266 80% 125,168, ,943,353 89% 127,395,218 80% 102,410,

73 Table UT Wattsmart Business Program Benefit/Cost Ratios Measure PTRC TRC UCT RIM PCT Business as Usual Proposed with Changes Proposed with Changes +10% Participation Proposed with Changes 10% Participation Lighting Only Business as Usual Lighting Only with Proposed Changes Lighting Only with Proposed Changes +10% Participation Lighting Only with Proposed Changes 10% Participation Cost Effectiveness Test Total Resource Cost Test (PTRC) + Conservation Adder Total Resource Cost Test (TRC) No Adder Table UT Wattsmart Business Program Business as Usual Cost Effectiveness Levelized Costs Benefits Net Benefits $/kwh Benefit/Cost Ratio $0.042 $137,439,444 $244,763,497 $107,324, $0.042 $137,439,444 $222,512,270 $85,072, Utility Cost Test (UCT) $0.024 $77,618,480 $222,512,270 $144,893, Rate Impact Test (RIM) $317,608,712 $222,512,270 ($95,096,442) 0.70 Participant Cost Test (PCT) $141,857,908 $341,734,914 $199,877, Discounted Participant Payback (years) 1.46 Lifecycle Revenue Impact ($/KWh) $

74 Cost Effectiveness Test Total Resource Cost Test (PTRC) + Conservation Adder Total Resource Cost Test (TRC) No Adder Table UT Wattsmart Business Program Proposed with Changes Cost Effectiveness Levelized Costs Benefits Net Benefits $/kwh Benefit/Cost Ratio $0.042 $131,462,657 $232,778,478 $101,315, $0.042 $131,462,657 $211,616,798 $80,154, Utility Cost Test (UCT) $0.021 $65,550,725 $211,616,798 $146,066, Rate Impact Test (RIM) $293,240,546 $211,616,798 ($81,623,748) 0.72 Participant Cost Test (PCT) $134,292,354 $314,097,019 $179,804, Discounted Participant Payback (years) 1.60 Lifecycle Revenue Impact ($/KWh) $ Cost Effectiveness Test Total Resource Cost Test (PTRC) + Conservation Adder Total Resource Cost Test (TRC) No Adder Table UT Wattsmart Business Program Proposed with Changes +10% Participation Cost Effectiveness Levelized $/kwh Costs Benefits Net Benefits Benefit/Cost Ratio $0.042 $144,453,917 $256,056,326 $111,602, $0.042 $144,453,917 $232,778,478 $88,324, Utility Cost Test (UCT) $0.021 $71,950,793 $232,778,478 $160,827, Rate Impact Test (RIM) $322,409,596 $232,778,478 ($89,631,118) 0.72 Participant Cost Test (PCT) $147,721,590 $345,506,721 $197,785, Discounted Participant Payback (years) 1.60 Lifecycle Revenue Impact ($/KWh) $

75 Table UT Wattsmart Business Program Proposed with Changes 10% Participation Cost Effectiveness Cost Effectiveness Test Levelized Benefit/Cost Costs Benefits Net Benefits $/kwh Ratio Total Resource Cost Test (PTRC) + Conservation $0.042 $118,471,396 $209,500,630 $91,029, Adder Total Resource Cost Test (TRC) No Adder $0.042 $118,471,396 $190,455,119 $71,983, Utility Cost Test (UCT) $0.021 $59,150,658 $190,455,119 $131,304, Rate Impact Test (RIM) $264,071,496 $190,455,119 ($73,616,378) 0.72 Participant Cost Test (PCT) $120,863,119 $282,687,317 $161,824, Discounted Participant Payback (years) 1.60 Lifecycle Revenue Impact ($/KWh) $ Cost Effectiveness Test Total Resource Cost Test (PTRC) + Conservation Adder Total Resource Cost Test (TRC) No Adder Table UT Wattsmart Business Program Lighting Only Business as Usual Cost Effectiveness Levelized Costs Benefits Net Benefits $/kwh Benefit/Cost Ratio $0.049 $60,135,358 $106,572,916 $46,437, $0.049 $60,135,358 $96,884,470 $36,749, Utility Cost Test (UCT) $0.027 $33,475,047 $96,884,470 $63,409, Rate Impact Test (RIM) $143,091,700 $96,884,470 ($46,207,231) 0.68 Participant Cost Test (PCT) $69,106,752 $164,786,130 $95,679, Discounted Participant Payback (years) 1.52 Lifecycle Revenue Impact ($/KWh) $

76 Cost Effectiveness Test Table UT Wattsmart Business Program Lighting Only with Proposed Changes Cost Effectiveness Levelized Costs Benefits Net Benefits $/kwh Benefit/Cost Ratio Total Resource Cost Test (PTRC) + Conservation $0.050 $54,196,265 $94,666,961 $40,470, Adder Total Resource Cost Test (TRC) No Adder $0.050 $54,196,265 $86,060,873 $31,864, Utility Cost Test (UCT) $0.020 $21,427,304 $86,060,873 $64,633, Rate Impact Test (RIM) $118,858,867 $86,060,873 ($32,797,994) 0.72 Participant Cost Test (PCT) $61,588,913 $137,314,222 $75,725, Discounted Participant Payback (years) 1.94 Lifecycle Revenue Impact ($/KWh) $ Cost Effectiveness Test Total Resource Cost Test (PTRC) + Conservation Adder Total Resource Cost Test (TRC) No Adder Table UT Wattsmart Business Program Lighting Only with Proposed Changes +10% Participation Cost Effectiveness Levelized $/kwh Costs Benefits Net Benefits Benefit/Cost Ratio $0.050 $59,577,141 $104,133,657 $44,556, $0.050 $59,577,141 $94,666,961 $35,089, Utility Cost Test (UCT) $0.020 $23,531,283 $94,666,961 $71,135, Rate Impact Test (RIM) $130,706,002 $94,666,961 ($36,039,042) 0.72 Participant Cost Test (PCT) $67,747,804 $151,045,644 $83,297, Discounted Participant Payback (years) 1.94 Lifecycle Revenue Impact ($/KWh) $

77 Cost Effectiveness Test Total Resource Cost Test (PTRC) + Conservation Adder Total Resource Cost Test (TRC) No Adder Table UT Wattsmart Business Program Lighting Only with Proposed Changes 10% Participation Cost Effectiveness Levelized $/kwh Costs Benefits Net Benefits Benefit/Cost Ratio $0.050 $48,815,390 $85,200,264 $36,384, $0.050 $48,815,390 $77,454,786 $28,639, Utility Cost Test (UCT) $0.020 $19,323,325 $77,454,786 $58,131, Rate Impact Test (RIM) $107,011,731 $77,454,786 ($29,556,946) 0.72 Participant Cost Test (PCT) $55,430,022 $123,582,800 $68,152, Discounted Participant Payback (years) 1.94 Lifecycle Revenue Impact ($/KWh) $

PacifiCorp s Planned Changes to wattsmart Business in Idaho May 2016

PacifiCorp s Planned Changes to wattsmart Business in Idaho May 2016 PacifiCorp s Planned Changes to wattsmart Business in Idaho May 2016 PacifiCorp is planning modifications to the wattsmart Business energy efficiency incentive program, which is offered through Schedule

More information

wattsmart Business Wyoming

wattsmart Business Wyoming Incentives for lighting retrofits Measure Category Eligibility Requirements Lighting retrofits See note 4 Customer Incentive $0.10/kWh annual Interior Lighting TLED relamp Lamp wattage reduction 10 watts,

More information

PacifiCorp s Planned Changes to wattsmart Business in Idaho December 2016

PacifiCorp s Planned Changes to wattsmart Business in Idaho December 2016 PacifiCorp s Planned Changes to wattsmart Business in Idaho December 2016 PacifiCorp is planning modifications to the wattsmart Business energy efficiency incentive program, which is offered through Schedule

More information

RE: Advice No Proposed Changes to Schedule 140, Non-Residential Energy Efficiency Program Docket No T09

RE: Advice No Proposed Changes to Schedule 140, Non-Residential Energy Efficiency Program Docket No T09 1407 W. North Temple, Suite 330 Salt Lake City, Utah 84116 July 10, 2017 VIA ELECTRONIC FILING Public Service Commission of Utah Heber M. Wells Building, 4 th Floor 160 East 300 South Salt Lake City, UT

More information

Surprising as it may sound,

Surprising as it may sound, wattsmart Business Idaho Rocky Mountain Power walked us through the process and worked with our electrician. It was a lot easier than I thought it would be. Dan West Owner Snake River Truss & Components

More information

Incentives for prescriptive measures are restricted to the amounts shown on the website.

Incentives for prescriptive measures are restricted to the amounts shown on the website. wattsmart Business Incentives for Measures Listed in the Incentive Tables Per unit incentives are listed in the program incentives tables for specific Energy Efficiency Measures (EEMs) and are subject

More information

Washington Non-Residential Energy Efficiency

Washington Non-Residential Energy Efficiency Washington Non-Residential Energy Efficiency This document includes the following three sections: Definitions of terms used in Schedule 140 and other program documents s General Information tables Definitions

More information

Surprising as it may sound,

Surprising as it may sound, wattsmart Business Wyoming Energy efficiency translates into reduced operating costs for the hospital. It s also an excellent way for us to be good stewards for our community we take that responsibility

More information

Washington Non-Residential Energy Efficiency

Washington Non-Residential Energy Efficiency Washington Non-Residential Energy Efficiency This document includes the following three sections: Definitions of terms used in Schedule 140 and other program documents Incentives General Information Incentive

More information

Surprising as it may sound,

Surprising as it may sound, wattsmart Business Washington Working with Pacific Power, we became very aware of how many dollars could be saved by paying attention to our energy usage. Malcolm Hanks Engineer Borton Fruit Surprising

More information

Washington Non-Residential Energy Efficiency

Washington Non-Residential Energy Efficiency Washington Non-Residential Energy Efficiency This document includes the following three sections: Definitions of terms used in Schedule 140 and other program documents Incentives General Information Incentive

More information

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 140 STATE OF UTAH. Non-Residential Energy Efficiency

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 140 STATE OF UTAH. Non-Residential Energy Efficiency P.S.C.U. No. 50 Original Sheet No. 140.1 ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 140 STATE OF UTAH Non-Residential Energy Efficiency PURPOSE: This Schedule is intended to maximize the efficient

More information

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 140 STATE OF UTAH. Non-Residential Energy Efficiency

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 140 STATE OF UTAH. Non-Residential Energy Efficiency P.S.C.U. No. 50 Original Sheet No. 140.1 ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 140 STATE OF UTAH Non-Residential Energy Efficiency PURPOSE: This Schedule is intended to maximize the efficient

More information

Surprising as it may sound,

Surprising as it may sound, wattsmart Business Wyoming Energy efficiency translates into reduced operating costs for the hospital. It s also an excellent way for us to be good stewards for our community we take that responsibility

More information

Surprising as it may sound,

Surprising as it may sound, wattsmart Business California Keeping up with the latest advances in lighting is not our area of expertise, but Pacific Power made it possible for us to make truly informed decisions before we upgraded.

More information

Exhibit A Program Descriptions, Historical Changes and Proposed Changes

Exhibit A Program Descriptions, Historical Changes and Proposed Changes Exhibit A Program Descriptions, Historical Changes and Proposed Changes Exhibit A Program Descriptions, Historical Changes and Changes Reflected in Forecasts Home Energy Savings The Home Energy Savings

More information

A change can do you good.

A change can do you good. RETROFIT INCENTIVES A change can do you good. Let s turn the answers on. FinAnswer Express California Is it costing more to run your facility than it should? Meek s branch manager Sandy Johnson (pictured

More information

FinAnswer Expresswattsmart Business Planned Changes

FinAnswer Expresswattsmart Business Planned Changes FinAnswer Expresswattsmart Business Planned Changes Planned FinAnswer Express Changes Planned changes are marked in the content below that was originally filed in Exhibit G, California FinAnswer Express

More information

wattsmart Business Utah

wattsmart Business Utah Incentives for lighting system retrofits Measure Category Eligibility Requirements Incentive Full fixture replacement Advanced controls $0.15/kWh annual Basic controls $0.12/kWh annual Interior lighting

More information

Surprising as it may sound,

Surprising as it may sound, wattsmart Business Utah It was great Rocky Mountain Power could help us achieve some of our goals. The more efficient you are, the less energy you re going to use. You re just trying to squeeze whatever

More information

PacifiCorp s Planned Changes to Home Energy Savings Program in Washington Effective for

PacifiCorp s Planned Changes to Home Energy Savings Program in Washington Effective for PacifiCorp s Planned Changes to Home Energy Savings Program in Washington Effective for 2014-2015 PacifiCorp (Company) is planning to make modifications to the Washington Home Energy Savings program (Program),

More information

PacifiCorp s Planned Changes to Home Energy Savings Program in Washington Effective for

PacifiCorp s Planned Changes to Home Energy Savings Program in Washington Effective for PacifiCorp s Planned Changes to Home Energy Savings Program in Washington Effective for 2016-2017 PacifiCorp (Company) is planning to make modifications to the Washington Home Energy Savings program (Program),

More information

SUMMARY OF SERVICES & INCENTIVES

SUMMARY OF SERVICES & INCENTIVES SMALL BUSINESS PROGRAM 2017 SUMMARY OF SERVICES & INCENTIVES Effective through December 31, 2017 Last updated February 1, 2017 EFFICIENCY INCENTIVES SUMMARY The Focus on Energy Small Business Program offers

More information

Rocky Mountain Power s Planned Changes to the Home Energy Savings Program in Idaho February 2017

Rocky Mountain Power s Planned Changes to the Home Energy Savings Program in Idaho February 2017 Rocky Mountain Power s Planned Changes to the Home Energy Savings Program in Idaho February 2017 PacifiCorp (Company) is planning to make modifications to the Home Energy Savings program (HES Program)

More information

Customer Benefits. Why Energy Efficiency? Consumers Energy Business Solutions. What Business Solutions Incentives Are Available?

Customer Benefits. Why Energy Efficiency? Consumers Energy Business Solutions. What Business Solutions Incentives Are Available? Why an Energy Efficiency Program? Business Solutions Energy Efficiency Incentive Program MPSC 21st Century Electric Energy Plan More electricity is needed as soon as practicable. One way of achieving this

More information

PacifiCorp s Planned Changes to the Home Energy Savings Program in California March 2014

PacifiCorp s Planned Changes to the Home Energy Savings Program in California March 2014 PacifiCorp s Planned Changes to the Home Energy Savings Program in California March 2014 PacifiCorp (Company) is planning to make modifications to the Home Energy Savings program (Program) for residential

More information

05/14/2012. How to Get Started with the Ameren Illinois ActOnEnergy Program. How to Get Started with ActOnEnergy Program

05/14/2012. How to Get Started with the Ameren Illinois ActOnEnergy Program. How to Get Started with ActOnEnergy Program How to Get Started with the Ameren Illinois ActOnEnergy Program Eric Kruzan, CEM How to Get Started with ActOnEnergy Program Getting Started... 1. Start with Where you use Energy your Systems 2. Where

More information

Pepco & Delmarva Power. Commercial & Industrial Energy Savings Program Hotels and Restaurants October 18, 2012

Pepco & Delmarva Power. Commercial & Industrial Energy Savings Program Hotels and Restaurants October 18, 2012 Pepco & Delmarva Power Commercial & Industrial Energy Savings Program Hotels and Restaurants October 18, 2012 Housekeeping The presentation will be emailed to you after the webinar. If you have technical

More information

1 Project Information. 2 Building Type. 3 Trade Ally/Contractor Information. HVAC Rebate Worksheet. Retrofit New Construction

1 Project Information. 2 Building Type. 3 Trade Ally/Contractor Information. HVAC Rebate Worksheet. Retrofit New Construction HVAC Rebate Worksheet Before you start Instructions: Complete all relevant information for your project. Include with complete application package. The HVAC Worksheet should be completed for new construction

More information

2019 MA Commercial & Industrial Energy Efficiency Offerings & Incentives

2019 MA Commercial & Industrial Energy Efficiency Offerings & Incentives 2019 MA Commercial & Industrial Energy Efficiency Offerings & Incentives P a g e 2 The Massachusetts Program Administrators (PAs) offer their business customers a wide array of financial incentives (1)

More information

Surprising as it may sound,

Surprising as it may sound, wattsmart Business California Keeping up with the latest advances in lighting is not our area of expertise, but Pacific Power made it possible for us to make truly informed decisions before we upgraded.

More information

Appendix E-1f: Small Building Methodology for Pre-SB2030 Projects

Appendix E-1f: Small Building Methodology for Pre-SB2030 Projects Appendix E-1f: Small Building Methodology for Pre-SB2030 Projects Prescriptive Bundle Option Method for Office Buildings less than 30,000 GSF This section describes energy strategy requirements for three

More information

Clean Energy Ally Program Orientation

Clean Energy Ally Program Orientation Clean Energy Ally Program Orientation PRESENTED BY Lisa Harmon B USINESS A L L IANCES M ANAGER 2 WHAT WE DO Help you make smart energy choices. Because smart energy choices reduce energy use save money

More information

Wakulla Chamber of Commerce July Place your cover photo here. Size and crop it to 4 high x 9.6 wide. Presented by Derick Farfan

Wakulla Chamber of Commerce July Place your cover photo here. Size and crop it to 4 high x 9.6 wide. Presented by Derick Farfan Wakulla Chamber of Commerce July 2017 Commercial Energy Efficiency Programs Place your cover photo here. Size and crop it to 4 high x 9.6 wide. Presented by Derick Farfan Energy Efficiency Incentives Question:

More information

ILLINOIS ENERGY NOW Energy Efficiency Incentives for State Facilities. December 2016

ILLINOIS ENERGY NOW Energy Efficiency Incentives for State Facilities. December 2016 ILLINOIS ENERGY NOW Energy Efficiency Incentives for State Facilities December 2016 1 ILLINOIS OFFICE OF ENERGY & RECYCLING Business Development Community Development Illinois Department of Commerce &

More information

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications. For purchases made on or after January 1, 2016

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications. For purchases made on or after January 1, 2016 EXHIBIT 1 Washington Home Energy Savings Program Measures, s, and For purchases made on or after January 1, 2016 Per unit incentives for specific Energy Efficiency Measures (EEMs) are listed in the program

More information

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications EXHIBIT 1 Washington Home Energy Savings Program Measures, s, and Per unit incentives for specific Energy Efficiency Measures (EEMs) are listed in the program incentive tables below. Current incentives

More information

Prescriptive Program. Terms And Conditions General Eligibility. Commercial and Industrial Customers. Rebate Checklist

Prescriptive Program. Terms And Conditions General Eligibility. Commercial and Industrial Customers. Rebate Checklist Prescriptive Program Industrial Customers Rebate Checklist Get your rebate check faster by checking off these easy steps before mailing your application form. Incomplete applications may be delayed. q

More information

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

DEEMED SAVINGS TECHNICAL ASSUMPTIONS Product: Description: Prescriptive rebates will be offered for replacement lighting equipment. New Construction rebates will be offered for new facilities or spaces overhauled for a new purpose. Custom

More information

New Jersey Board of Public Utilities Clean Energy Program Incentives and Proposed Hurricane Sandy Storm Response

New Jersey Board of Public Utilities Clean Energy Program Incentives and Proposed Hurricane Sandy Storm Response New Jersey Board of Public Utilities Clean Energy Program Incentives and Proposed Hurricane Sandy Storm Response Energy Efficient Equipment and Building Upgrades February 2013 Program Goals Save energy

More information

What products are eligible for the rebate? < 149 tons > 150 tons

What products are eligible for the rebate? < 149 tons > 150 tons If you have questions while completing this form, please contact Energy Management Solutions, Inc. weekdays during business hours for assistance. Phone: 952-767-7450 Fax: 952-556-9171 Send your completed

More information

Appendix B 2019 Commercial Unitary Air Conditioning and Heat Pumps Specification

Appendix B 2019 Commercial Unitary Air Conditioning and Heat Pumps Specification Appendix B 2019 Commercial Unitary Conditioning and Heat Pumps Specification Unitary Conditioner Specification Effective January 1, 2019 Equipment Type Cooled (Cooling Mode) Water Cooled Size Category

More information

e.catalog Product Acceptance Criteria April 2008

e.catalog Product Acceptance Criteria April 2008 e.catalog Product Acceptance Criteria April 2008 TABLE OF CONTENTS E.CATALOG PRODUCT ACCEPTANCE CRITERIA...4 E.CATALOG ENERGY EFFICIENCY CRITERIA...4 LAMPS...6 COMPACT FLUORESCENT LAMPS...6 SCREW-IN COLD

More information

2012 Energy Efficiency Program Update Commercial, Agriculture, & Industrial California June 5 th (Crescent City) June 6 th (Yreka)

2012 Energy Efficiency Program Update Commercial, Agriculture, & Industrial California June 5 th (Crescent City) June 6 th (Yreka) 2012 Energy Efficiency Program Update Commercial, Agriculture, & Industrial California June 5 th (Crescent City) June 6 th (Yreka) Introductions Welcome Pacific Power Energy Efficiency Alliance staff Other

More information

COMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION

COMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION COMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION 1. CUSTOMER INFORMATION (please print) Account Name Doing Business As (if different from Account Name) Installation Address City State Zip Code Mailing

More information

INCENTIVE ESTIMATOR HVAC USER GUIDE CONTENTS FLORIDA CUSTOM INCENTIVE PROGRAM

INCENTIVE ESTIMATOR HVAC USER GUIDE CONTENTS FLORIDA CUSTOM INCENTIVE PROGRAM INCENTIVE ESTIMATOR HVAC USER GUIDE FLORIDA CUSTOM INCENTIVE PROGRAM CONTENTS 1. Getting Started... 2 2. Measure Tool Description... 3 2.1. Appropriate Use of the Tool... 3 2.2. Applicable Types of Air

More information

Policies & Procedures Manual

Policies & Procedures Manual Policies & Procedures Manual Ver. 4.0 Rev. 9-01-13 1/2/2014 9:53 AM Table of Contents 1. Program Overview... 4 1.1 Incentive Types... 4 2. Program Effective Dates... 5 3. Customer Eligibility... 5 4. Project

More information

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

DEEMED SAVINGS TECHNICAL ASSUMPTIONS Product: Prescriptive rebates will be offered for replacement lighting equipment. New Construction rebates will be offered for new facilities or spaces overhauled for a new purpose. Custom rebates are

More information

COMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION

COMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION COMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION SECTION A. CUSTOMER INFORMATION (please print) Account Name Doing Business As (if different from Account Name) Installation Address City State Zip Code

More information

Exhibit # MH-142 Transcript Page #5761. Manitoba Hydro to provide spreadsheet analysis performed comparing Xcel Energy's Programs to MH s Programs.

Exhibit # MH-142 Transcript Page #5761. Manitoba Hydro to provide spreadsheet analysis performed comparing Xcel Energy's Programs to MH s Programs. Exhibit # MH-142 Transcript Page #5761 Manitoba Hydro Undertaking #135 Manitoba Hydro to provide spreadsheet analysis performed comparing Xcel Energy's Programs to MH s Programs. Please see attached internal

More information

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings. ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD 90.1-2010 (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings March 8, 2018 The corrections listed in this errata sheet apply to

More information

Reducing Costs with Energy Efficiency

Reducing Costs with Energy Efficiency Reducing Costs with Energy Efficiency Presented to Pennsylvania Demand Side Response Working Group February 9, 2007 2/9/2007 1 Austin Energy Municipally-owned 700,000 population Area > 400 sq. miles Generation

More information

Grays Harbor PUD Energy Services. Commercial, Industrial, Agricultural Incentive Program Catalog IT S YOUR PUD!

Grays Harbor PUD Energy Services. Commercial, Industrial, Agricultural Incentive Program Catalog IT S YOUR PUD! Grays Harbor PUD Energy Services Commercial, Industrial, Agricultural Incentive Program Catalog IT S YOUR PUD! This catalog outlines the available incentives for making energy efficient improvements at

More information

ANNUAL STAKEHOLDER MEETING

ANNUAL STAKEHOLDER MEETING ANNUAL STAKEHOLDER MEETING 2015 Technical Reference Manual High Impact C&I Measure Updates July 11, 2014 Presented by the Statewide Evaluation Team: MEETING AGENDA MEETING AGENDA Weather Mapping Lighting

More information

Title 24: Where We're Headed with the 2013 Standards. Featuring: Martyn C. Dodd EnergySoft, LLC

Title 24: Where We're Headed with the 2013 Standards. Featuring: Martyn C. Dodd EnergySoft, LLC Title 24: Where We're Headed with the 2013 Standards Featuring: Martyn C. Dodd EnergySoft, LLC www.energysoft.com Overall Changes in Scope and Application Welcome Overall Changes in Scope and Application

More information

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

DEEMED SAVINGS TECHNICAL ASSUMPTIONS Product: Description: Prescriptive rebates will be offered for replacement lighting equipment. New Construction rebates will be offered for new facilities or spaces overhauled for a new purpose. Custom

More information

Policies & Procedures Manual

Policies & Procedures Manual Policies & Procedures Manual Ver. 4.2 Rev. 4-01-15 Table of Contents 1. Program Overview... 4 1.1 Incentive Types... 4 2. Program Effective Dates... 5 3. Customer Eligibility... 5 4. Project Requirements...

More information

PacifiCorp Annual Review of DSM Programs California

PacifiCorp Annual Review of DSM Programs California PacifiCorp 2009 Annual Review of DSM Programs California PacifiCorp Demand Side Management Team 3/15/2010 Table of Contents Introduction... 2 2009 Performance and Activity... 3 Stakeholder Meetings, Communications

More information

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings. ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD 90.1-2010 (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings April 17, 2013 The corrections listed in this errata sheet apply to

More information

COMMERCIAL & INDUSTRIAL

COMMERCIAL & INDUSTRIAL Energy-Smart Solutions from Your Local Electric Cooperative 2018 COMMERCIAL & INDUSTRIAL PROGRAM APPLICATION HAVE QUESTIONS OR NEED HELP COMPLETING YOUR APPLICATION? CALL 877.653.8288 OR EMAIL APPLY@POWERMOVES.COM.

More information

New Jersey Board of Public Utilities Clean Energy Program Opportunities for Commercial, Industrial and Institutional Buildings

New Jersey Board of Public Utilities Clean Energy Program Opportunities for Commercial, Industrial and Institutional Buildings New Jersey Board of Public Utilities Clean Energy Program Opportunities for Commercial, Industrial and Institutional Buildings Gary E Finger Ombudsman June 2013 NJ Clean Energy Program Background Introduced

More information

Heating and Cooling Incentive Application for Business Customers

Heating and Cooling Incentive Application for Business Customers 2019 Heating and Cooling Incentive Application for Business Customers A Cash Incentive Energy Efficiency Program brought to you by: IMPORTANT INSTRUCTIONS: Step 1: Determine Eligibility: Pre-approval is

More information

Fifteen Year Plan for Energy Efficiency and Conservation Projects

Fifteen Year Plan for Energy Efficiency and Conservation Projects Fifteen Year Plan for Energy Efficiency and Conservation Projects Presented to the Board of Trustees of the Northeastern Ohio Universities Colleges of Medicine and Pharmacy, December, 2008, in accordance

More information

Heating and Cooling Incentive Application for Business Customers

Heating and Cooling Incentive Application for Business Customers 2019 Heating and Cooling Incentive Application for Business Customers A Cash Incentive Energy Efficiency Program brought to you by: IMPORTANT INSTRUCTIONS: Step 1: Determine Eligibility: Pre-approval is

More information

Heating and Cooling Incentive Application for Business Customers

Heating and Cooling Incentive Application for Business Customers 2019 Heating and Cooling Incentive Application for Business Customers A Cash Incentive Energy Efficiency Program brought to you by: IMPORTANT INSTRUCTIONS: Step 1: Determine Eligibility: Pre-approval is

More information

Heating and Cooling Incentive Application for Business Customers

Heating and Cooling Incentive Application for Business Customers 2019 Heating and Cooling Incentive Application for Business Customers A Cash Incentive Energy Efficiency Program brought to you by: IMPORTANT INSTRUCTIONS: Step 1: Determine Eligibility: Pre-approval is

More information

Prepared for Idaho Power Company October 15, Prepared by: ADM Associates, Inc Ramos Circle Sacramento, CA (916)

Prepared for Idaho Power Company October 15, Prepared by: ADM Associates, Inc Ramos Circle Sacramento, CA (916) Technical Reference Manual 2.2 Prepared for Idaho Power Company October 15, 2018 Prepared by: ADM Associates, Inc. 3239 Ramos Circle Sacramento, CA 95827 (916) 363-8383 Chapter Title i Table of Contents

More information

Pennsylvania Watt Watchers. Business Programs

Pennsylvania Watt Watchers. Business Programs Pennsylvania Watt Watchers Business Programs Why does a utility company want me to reduce electricity usage? Pennsylvania Act 129 Signed into law by Governor Rendell - October 2008. Establishes new requirements

More information

GreenStep Cities Workshop Xcel Energy Rebates: Commercial Program Overview

GreenStep Cities Workshop Xcel Energy Rebates: Commercial Program Overview GreenStep Cities Workshop Xcel Energy Rebates: Commercial Program Overview Mike Meyers, Xcel Energy Commitment from Leadership Our energy conservation programs are especially valuable because they give

More information

Surprising as it may sound,

Surprising as it may sound, wattsmart Business Idaho We are very, very pleased with how the buildings are performing for us. We are consuming a small fraction of the electricity that we were previously. Stafford Smith Owner The Smith

More information

SCE Comments on DEER2016 Update Scope

SCE Comments on DEER2016 Update Scope SCE Comments on DEER2016 Update Scope Submitted February 27, 2015 Below, please find a combination of proposed requests, queries, and technical feedback by Southern California Edison (SCE) pertaining to

More information

Heating and Cooling Incentive Application for Business Customers

Heating and Cooling Incentive Application for Business Customers 2019 Heating and Cooling Incentive Application for Business Customers A Cash Incentive Energy Efficiency Program brought to you by: IMPORTANT INSTRUCTIONS: Step 1: Determine Eligibility: Pre-approval is

More information

Energy Efficiency Opportunities. Chris Sarine (423)

Energy Efficiency Opportunities. Chris Sarine (423) Energy Efficiency Opportunities Chris Sarine csarine@itseesy.com (423) 503-0130 Lighting introduction to efficient lighting 40-80% Typical LED Wattage Reduction Why focus on efficient lighting? Lighting

More information

BETA OPTION 1: PERFORMANCE RATING METHOD. Section General Information

BETA OPTION 1: PERFORMANCE RATING METHOD. Section General Information LEED-CS 2. Certification Submittal Template OPTION 1: PERFORMANCE RATING METHOD I confirm that the energy simulation software used for this project has all capabilities described in EITHER section `G2

More information

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST ENVELOPE REQUIREMENTS Project: Date: Instructions RECOMMENDED: List performance values, note exceptions that were applied, or provide other

More information

Efficiency Works Business Programs Guide 2019

Efficiency Works Business Programs Guide 2019 Efficiency Works Business Programs Guide 2019 Revised: January 11, 2019 TABLE OF CONTENTS EFFICIENCY WORKS BUSINESS OVERVIEW... 3 CONTACT INFORMATION... 3 UTILITY SERVICE TERRITORY... 4 GENERAL PARTICIPATION

More information

Energy Auditing for Schools. Maryland Energy Administration Eric Oliver, EMO Energy Solutions, LLC May 10, 2007

Energy Auditing for Schools. Maryland Energy Administration Eric Oliver, EMO Energy Solutions, LLC May 10, 2007 Energy Auditing for Schools Maryland Energy Administration Eric Oliver, EMO Energy Solutions, LLC May 10, 2007 Schools Consumption breakdown 19% 6% 9% Space Heating 46% Water Heating Lighting Cooling 20%

More information

What s My Baseline? ASHRAE

What s My Baseline? ASHRAE 2010 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions (2010, vol 116,part 2). For personal use only. Additional reproduction,

More information

Retail Effects of ANSI/ASHRAE/IES Standard

Retail Effects of ANSI/ASHRAE/IES Standard Retail Effects of ANSI/ASHRAE/IES Standard 90.1-2016 Prepared by Dialectic Inc. INTRODUCTION Background ANSI/ASHRAE/IES 90.1-2016 Energy Standard for Buildings Except Low-Rise Residential Buildings replaces

More information

TNMP s. Commercial Energy Efficiency Programs Kick-off Webinar. January 23,

TNMP s. Commercial Energy Efficiency Programs Kick-off Webinar. January 23, TNMP s Commercial Energy Efficiency Programs Kick-off Webinar January 23, 2014 Agenda Introductions Program Overviews SCORE CitySmart Commercial Solutions 2013 Program Results 2014 Program Updates and

More information

PECO Smart Ideas for Your Business

PECO Smart Ideas for Your Business PECO Smart Ideas for Your Business April 2015 Agenda PECO Smart Ideas incentive programs Program measures and process Tools and Trade Allies 2 1 PECO Smart Ideas PA Act 129 Program incentives designed

More information

FirstEnergy s Pennsylvania Utilities. Energy Efficiency Programs for Business

FirstEnergy s Pennsylvania Utilities. Energy Efficiency Programs for Business FirstEnergy s Pennsylvania Utilities Energy Efficiency Programs for Business 2018 TODAY S AGENDA Introduction to Sodexo Summary of Pennsylvania Act 129 Overview of program website Overview of Application

More information

is consciousness and action

is consciousness and action Kaua`i Renewable Energy Conference Miles Kubo President/COO September 8, 28 Energy Conservation is consciousness and action Turn off a light Walk a flight of stairs Shut down computers Unplug phantom loads

More information

DTE Energy Commercial & Industrial Energy Optimization Program. Trade Ally Meeting. Guardian Plumbing & Heating January 20, 2011

DTE Energy Commercial & Industrial Energy Optimization Program. Trade Ally Meeting. Guardian Plumbing & Heating January 20, 2011 DTE Energy Commercial & Industrial Energy Optimization Program Trade Ally Meeting Guardian Plumbing & Heating January 20, 2011 Agenda Introduction DTE Energy Your Energy Savings Program Overview 2011 Program

More information

Energy Efficiency and Reduction. Tribal Lands and Environment Forum August 15, 2016

Energy Efficiency and Reduction. Tribal Lands and Environment Forum August 15, 2016 Energy Efficiency and Reduction Tribal Lands and Environment Forum August 15, 2016 Energy Efficiency versus Energy Conservation Energy Conservation using less of an energy service Examples include: Turning

More information

Pepco C&I Energy Savings Program. AOBA Briefing April 27, 2011

Pepco C&I Energy Savings Program. AOBA Briefing April 27, 2011 Pepco C&I Energy Savings Program AOBA Briefing April 27, 2011 Program Eligibility Pepco s Maryland commercial and industrial customers are eligible for CASH incentives for projects that reduce electric

More information

Local Government Energy Audit:

Local Government Energy Audit: Local Government Energy Audit: i Energy Audit Report Lift Station #1, 3, 5, 6, 7, 8, and 9 Copyright 2018 TRC Energy Services. All rights reserved. Reproduction or distribution of the whole, or any part

More information

MidAmerican Energy 2017 Trade Ally Meeting

MidAmerican Energy 2017 Trade Ally Meeting MidAmerican Energy 2017 Trade Ally Meeting Agenda 2017 EE Program Performance insight IA 2019-2023 Energy Efficiency Plan IL 2019-2023 Energy Efficiency Plan 2018 Program Changes Experience the Trade Ally

More information

Existing Building Upgrades

Existing Building Upgrades Existing Building Upgrades Shawn Maurer SEDAC Building Energy Specialist Smart Energy Design Assistance Center (SEDAC), University of Illinois at Urbana Champaign SEDAC ILLINOIS K-12 SCHOOL ENERGY USE

More information

University of Minnesota Duluth Civil Engineering Building

University of Minnesota Duluth Civil Engineering Building Energy Data Attachment University of Minnesota Duluth Civil Engineering Building LEED Energy Modeling The energy modeling for LEED NC 2.2 was performed against ASHRAE 9.1-24 Appendix using equest version

More information

Consumers Energy Business Solutions. Commercial and Industrial Energy Efficiency Program January 15, 2013

Consumers Energy Business Solutions. Commercial and Industrial Energy Efficiency Program January 15, 2013 Consumers Energy Business Solutions Commercial and Industrial Energy Efficiency Program January 15, 2013 1 David MacDonald Senior Marketing Manager TODAY S PRESENTER 2 3 Today s Topics Program Summary

More information

Commercial & Industrial Energy Optimization Programs

Commercial & Industrial Energy Optimization Programs SP Energy and Water Work Group Breakfast Meeting Commercial & Industrial Energy Optimization Programs May 2, 2011 Agenda Introduction DTE Energy Your Energy Savings Program Overview 2011 Program Changes

More information

Minnesota Conservation

Minnesota Conservation Program Information MN Minnesota Conservation Programs Summary We offer solutions for business customers in a suite of energy conservation and energy management products that will help you increase your

More information

CREDIT COMPLIANCE (Please complete the color coded criteria(s) based on the option path selected)

CREDIT COMPLIANCE (Please complete the color coded criteria(s) based on the option path selected) (Responsible Individual) (Company Name) I,, from verify that the information provided below is accurate, to the best of my knowledge. CREDIT COMPLIANCE (Please complete the color coded criteria(s) based

More information

The baseline building system for compliance with Senate Bill 668 is defined by Appendix G,

The baseline building system for compliance with Senate Bill 668 is defined by Appendix G, Project: North Carolina A&T State University New Student Health Center SCO #: 08-08109-01A 1.0 Heating, Ventilating and Air Conditioning (HVAC) Baseline Building Systems Senate Bill 668 Compliance The

More information

2015 FOCUS ON ENERGY PROGRAM UPDATES TRADE ALLY WEBINAR

2015 FOCUS ON ENERGY PROGRAM UPDATES TRADE ALLY WEBINAR 2015 FOCUS ON ENERGY PROGRAM UPDATES TRADE ALLY WEBINAR 12.18.14 AGENDA Introduction Residential Program Updates Business Program Updates Renewable Energy Updates Marketing Overview Outreach INTRODUCTION

More information

South Carolina Society for Hospital Engineers

South Carolina Society for Hospital Engineers South Carolina Society for Hospital Engineers Selecting Energy Partners: Criteria & Pitfalls and the Top 10 Ways to Reduce Energy in a Hospital Presented by Jon Dierking, PE, CEM, LEED AP Director of Energy

More information

Welcome. Boston Green Tourism March 9, 2017

Welcome. Boston Green Tourism March 9, 2017 Welcome Boston Green Tourism March 9, 2017 Agenda Welcome PA 2016 Results Customer Facing Teams 2017 Program Priorities Enhancing the Energy Efficiency Experience Program & Application Highlights Closing

More information

III. To evaluate the infrastructure to ensure an efficient operating system if the project affects any component of the building infrastructure.

III. To evaluate the infrastructure to ensure an efficient operating system if the project affects any component of the building infrastructure. New York University Design Standards: Energy and Water Guidelines 1. Introduction New construction and renovation at NYU shall be designed to meet or exceed Energy Performance Targets. Some strategies

More information

2017 Lighting Program Colorado: Commercial and Industrial Electric Customers

2017 Lighting Program Colorado: Commercial and Industrial Electric Customers Black Hills Energy offers Colorado Commercial and Industrial electric customers rebates for some of the most commonly installed lighting projects. We offer commercial customers two options to receive rebates.

More information