400 Gal. Grease Interceptor

Size: px
Start display at page:

Download "400 Gal. Grease Interceptor"

Transcription

1 400 Gal. Grease Interceptor PC Secondary chamber volume equal to 1/2 total capacity. Verify compliance with local regulations. STM-C-478 specifications for water and wastewater structures. utyl meets or exceeds Fed. Spec. SS-S-210. (Provided with tank) SSHTO H-20 traffic rated. Plumbing provided by others. TOP VIEW 3" Vent hole 2 42" 2 #3 Lift loop 3" #3 Lift loop Cast iron ring & cover Optional grade adjustment ring Traffic rated lid 32" 58" FFLE Seal Inlet 48" 48" Seal Outlet 47" utyl 8" 49" 58" 3" 47 1 /2"

2 500 Gal. Grease Interceptor PC Secondary chamber volume equal to 1/2 total capacity. Verify compliance with local regulations. STM-C-478 specifications for water and wastewater structures. utyl meets or exceeds Fed. Spec. SS-S-210. (Provided with tank) SSHTO H-20 traffic rated. Plumbing provided by others. TOP VIEW 3" Vent hole 2 42" 2 #3 Lift loop 3" #3 Lift loop Cast iron ring & cover Optional grade adjustment ring Traffic rated lid 32" 58" 48" FFLE 75" 48" 2 7 Inlet and outlet in riser section utyl 70" 1 58" 3" 47 1 /2"

3 1000 Gal. Grease Interceptor Secondary chamber volume equal to 1/3 total capacity. for water and wastewater structures. utyl meets or exceeds Fed. Spec. SS-S (Provided with tank) SSHTO H-20 traffic rated. Plumbing shown in diagram provided by others. SECTION 9" TOP SL - TYPICL REINFORCEMENT utyl 3.5" affle wall 1000 Vent pipe 2 Ø Ring/Cover 5'- Outlet 52" 5'-10" 8'- PC ,995 lbs 2,550 lbs 910 lbs 10,455 lbs

4 1250 Gal. Grease Interceptor Secondary chamber volume equal to 1/3 total capacity. for water and wastewater structures. utyl meets or exceeds Fed. Spec. SS-S (Provided with tank) SSHTO H-20 traffic rated. Plumbing shown in diagram provided by others. SECTION TOP SL - TYPICL REINFORCEMENT 1250 Vent pipe 2 Ø Ring/Cover 5'- 9" 3.5" utyl affle wall Outlet 52" 5'-10" 10'- PC ,430 lbs 3,370 lbs 910 lbs 12,710 lbs

5 1500 Gal. Grease Interceptor Secondary chamber volume equal to 1/3 total capacity. for water and wastewater structures. utyl meets or exceeds Fed. Spec. SS-S (Provided with tank) SSHTO H-20 traffic rated. Plumbing shown in diagram provided by others. SECTION 9" TOP SL - TYPICL REINFORCEMENT utyl 1500 Vent pipe affle wall 2 Ø Ring/Cover 6'-8" Outlet 52" 5'-10" 10'-2" PC ,615 lbs 3,900 lbs 1,110 lbs 14,625 lbs

6 2000 Gal. Grease Interceptor Secondary chamber volume equal to 1/3 total capacity. for water and wastewater structures. utyl meets or exceeds Fed. Spec. SS-S (Provided with tank) SSHTO H-20 traffic rated. Plumbing shown in diagram provided by others. section 9" top sl - typicl REinFoRCEmEnt utyl 2000 Vent pipe affle wall 2 Ø Ring/Cover 6'-8" Outlet 52" 5'-10" 12'-8" PC ,690 lbs 5,145 lbs 1,110 lbs 17,945 lbs

7 2500 Gal. Grease Interceptor Secondary chamber volume equal to 1/3 total capacity. for water and wastewater structures. utyl meets or exceeds Fed. Spec. SS-S (Provided with tank) SSHTO H-20 traffic rated. Plumbing shown in diagram provided by others. section 8" 60" top sl - typicl REinFoRCEmEnt 3.5" utyl 2250 Vent pipe affle wall 2 Ø Ring/Cover 6'- Outlet 57" 11" 6'-2" 13'-10" PC ,890 lbs 5,400 lbs 1,560 lbs 18,850 lbs

8 3250 Gal. Grease Interceptor Total Capacity: 3365 gallons Secondary chamber volume equal to 1/3 total capacity. STM- C-913 specifications for water and wastewater structures. utyl meets or exceeds Fed. Spec. SS-S (Provided with tank) SSHTO H-20 traffic rated. Plumbing provided by others. 3'-0" 8 typical Inlet Invert 2 Clear access opening 6'-8" 6'-8" 83" typical Outlet Invert 8'- Four (4) 1" GR. #8 rods / isometric tension devices 5'- 12'-8" PC ,690 lbs 7,715 lbs 1,110 lbs 20,515 lbs

APPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes

APPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes Precast roof slabs refer Standard Drawing CMDG-D-03 Special cast iron cover and frame, refer Service Authority. Special cast iron cover and frame, refer Service Authority. Cast iron cover and frame Ø 200

More information

SECTION SANITARY WASTE INTERCEPTORS

SECTION SANITARY WASTE INTERCEPTORS SECTION 22 13 23 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable in the section

More information

Environmental Products. Designed to Protect and Improve Our Environment. Delivering Reliability

Environmental Products. Designed to Protect and Improve Our Environment. Delivering Reliability Delivering Reliability A Designed to Protect and Improve Our Environment Environmental Products Sales & Service 888-9Oldcastle (888-965-3227) A Environmentally Responsible COVER & FRAME Oldcastle Precast

More information

GB-20. Submittal Specifications Installation Application Specific Details

GB-20. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 27" (68.6 cm) 4¼" (10.8 cm) 15" (38.1 cm) 10¾" (27.3 cm) SUBMITTAL (53.3 cm) STANDARD: 2" plain end

More information

SECTION SANITARY WASTE INTERCEPTORS

SECTION SANITARY WASTE INTERCEPTORS SECTION 22 13 23 SANITARY WASTE INTERCEPTORS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

GB-25. Submittal Special Precautions Specifications Installation Application Specific Details

GB-25. Submittal Special Precautions Specifications Installation Application Specific Details Submittal Special Precautions Specifications Installation Application Specific Details 27" (68.6 cm) 4¼" (10.8 cm) 15" (38.1 cm) 10¾" (27.3 cm) SUBMITTAL 21" (53.3 cm) STANDARD: 3" plain end inlet/outlet

More information

GB-75. Submittal Specifications Installation Application Specific Details

GB-75. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 38½" 51½" (1,308 (978 mm) 13½" 12½" (343 (318 mm) 38" 26" (660 (965 mm) 68" 46" (1,168 (1,727 mm) 33½"

More information

GB-75. High Efficiency Grease Interceptor Technical Data. Submittal Specifications Installation Application Specific Details

GB-75. High Efficiency Grease Interceptor Technical Data. Submittal Specifications Installation Application Specific Details High Efficiency Grease Interceptor Technical Data Submittal Specifications Installation Application Specific Details 38½" 38.5" (97.8 cm) 12½" (31.7 cm) 26" (66.0 cm) 46" (116.8 cm) 33½" 32" (851 (81.3

More information

Product Catalogue 2014

Product Catalogue 2014 Product Catalogue 2014 Tradewaste & Septic Solutions Process blue Black The work of the Tradewaste and Septic industries is critical for the well-being of our fragile ecosystem. Through ongoing research,

More information

1 Exam Prep Chapter 64E -6 Questions and Answers

1 Exam Prep Chapter 64E -6 Questions and Answers 1 Exam Prep Chapter 64E -6 Questions and Answers Part One 1. According to Florida Rules: Chapter 64E-6, if building construction has commenced, for how many additional days past the eighteen month expiration

More information

Tank Functions. Solids removal by settling & floatation. Anaerobic digestion Storage of solids % solids removal

Tank Functions. Solids removal by settling & floatation. Anaerobic digestion Storage of solids % solids removal Tank Functions Solids removal by settling & floatation 60-80% solids removal Anaerobic digestion Storage of solids Average Removal of BOD, TSS, and Grease in Septic Tank Parameter Average Raw Sewage Influent

More information

Inlets & Catch Basins

Inlets & Catch Basins A Delivering Reliability Inlets & Catch Basins Water-Conveyance & Drainage A Environmentally Responsible Oldcastle Precast to the Rescue All of our products are produced in a controlled environment helping

More information

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation Gravity Grease Technical Data Submittal Special Precautions Specifications Installation 75" 81" (205.7 (94.0 cm) 19½" 20" (50.8 (49.5 cm) 21½" 20" (50.8 (54.6 cm) 76½" (194.3 cm) 56½" 57" (144.8 (143.5

More information

Section 10 Design Criteria: Components

Section 10 Design Criteria: Components 1. Tanks and Vaults Section 10 Design Criteria: Components a. Watertightness i. Septic tanks, vaults, dosing tanks, other treatment components, risers and lids must not allow infiltration of ground water

More information

INYO COUNTY ENVIRONMENTAL HEALTH SERVICES RESIDENTIAL ONSITE SEWAGE TREATMENT AND DISPOSAL GUIDE

INYO COUNTY ENVIRONMENTAL HEALTH SERVICES RESIDENTIAL ONSITE SEWAGE TREATMENT AND DISPOSAL GUIDE INYO COUNTY ENVIRONMENTAL HEALTH SERVICES RESIDENTIAL ONSITE SEWAGE TREATMENT AND DISPOSAL GUIDE I. SCOPE This guide has been prepared to inform the residential property owner of the permitting process

More information

Central Concrete Product Limited. Product Catalogue

Central Concrete Product Limited. Product Catalogue January 2007 Concrete Pipes Reinforced Concrete Pipe Internal Wall Thickness Pipe Strengths Pipe Pipe Weight Diameter (mm) Length (kg) (mm) B Wall C Wall B Wall C Wall (mm) B Wall C Wall 300 50 n/a Class

More information

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm) Wastewater Flow Distributor Technical Data Submittal Special Precautions Specifications Installation 24½" (62.2 cm) 12½" (31.8 cm) 24½" (62.2 cm) (30.5 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet

More information

Introduction. Installation

Introduction. Installation ADVANCE CONCRETE & PRE-CAST HOLDING PTY LTD A.C.N.083 235 536 50 Victoria street Riverstone N.S.W. P.O Box130 Riverstone n.s.w. 2765 Phone 02 96276476 fax 02 96276478 Introduction To supply Grease Traps

More information

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

SV24. Submittal Special Precautions Specifications Installation. 12½ (31.8 cm) 12½ (31.8 cm) 12 (30.5 cm) 12 (30.5 cm) 12 (30. Wastewater Sampling Port Technical Data Submittal Special Precautions Specifications Installation 16½" (31.8 (41.9 cm) 8" (20.3 cm) -L -O SUBMITTAL STANDARD: 4" plain end inlet/outlet Highway traffic load

More information

EVERY ITEM WILL BE REVIEWED AND NOTED FOR COMPLIANCE (C), OR NON-APPLICABILITY (NA).

EVERY ITEM WILL BE REVIEWED AND NOTED FOR COMPLIANCE (C), OR NON-APPLICABILITY (NA). DESIGN LIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED EVERY WILL BE REVIEWED AND NOTED FOR COMPLIANCE (C), OR NON-APPLICABILITY (NA). SECTION 11 - PLUMBING A GENERAL - Check 1.

More information

TABLE OF CONTENTS

TABLE OF CONTENTS DIVISION 33: SEWER AND SEPTIC SYSTEMS 33 3633 UTILITY SEPTIC TANK DRAINAGE FIELD TABLE OF CONTENTS 33 0000-1 SECTION 33 3633-- UTILITY SEPTIC TANK DRAINAGE FIELD PART 1 - GENERAL 1.1 SUMMARY A. Includes

More information

Incorrect sizing, improper installation and/or inefficient maintenance will affect the performance of Proceptor separators.

Incorrect sizing, improper installation and/or inefficient maintenance will affect the performance of Proceptor separators. 3 Sizing Guidelines Proceptor sizing information is based on best available data including laboratory testing (inhouse), field testing, theoretical modeling, and monitoring studies. Proceptor sizing information

More information

FS-TRIO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.

FS-TRIO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62. Wastewater Flow Distributor Technical Data Submittal Special Precautions Specifications Installation 24½" (62.2 cm) 12½" (31.8 cm) 24½" (62.2 cm) (30.5 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet

More information

Miscellaneous and Cast Iron Listings

Miscellaneous and Cast Iron Listings aeconcrete.com May 2017 Miscellaneous and Cast Iron Listings Drawing Number Item Description Product Size (Length X Width X Depth in mm) SVVZ-20-SUMP-C Drainage Sump w/ Cover 660 x 510 x 765 i.d. SVVZ-NC-SUMP-C

More information

Grease Management. EnduraGreaseManagement.com. Rethinking Grease Interception

Grease Management. EnduraGreaseManagement.com. Rethinking Grease Interception Grease Management EnduraGreaseManagement.com Rethinking Grease Interception Endura has the right stuff The Right Reason Guided by a philosophy of minimizing downstream toxic waste, Endura engineers have

More information

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation Gravity Grease Technical Data Submittal Special Precautions Specifications Installation 75" 81" (205.7 (94.0 cm) 19½" 20" (50.8 (49.5 cm) 21½" 20" (50.8 (54.6 cm) 76½" (194.3 cm) 56½" 57" (144.8 (143.5

More information

SECTION PRECAST CONCRETE MANHOLES

SECTION PRECAST CONCRETE MANHOLES SECTION 02601 PRECAST CONCRETE MANHOLES PART 1 GENERAL 1.1 The work specified in this section shall include the furnishing, hauling, and placing of all precast manholes shown on the drawings and as specified

More information

Lifetime Guaranteed Construction with unique built-in installation and maintenance features

Lifetime Guaranteed Construction with unique built-in installation and maintenance features Lifetime Guaranteed Construction with unique built-in installation and maintenance features Great Basin grease interceptors provide the best in quality materials and engineered craftsmanship. Units are

More information

Site Plan: General: Common Omissions-Mistakes on Plans: Ohio EPA Southeast District Office Logan, Ohio November 22, 2005 Bruce Goff, P.E.

Site Plan: General: Common Omissions-Mistakes on Plans: Ohio EPA Southeast District Office Logan, Ohio November 22, 2005 Bruce Goff, P.E. Common Omissions-Mistakes on Plans: Ohio EPA Southeast District Office Logan, Ohio 43138 November 22, 2005 Bruce Goff, P.E. Site Plan: Inadequate site survey, e.g. no topographic contours Locations of

More information

Maelstrom. Installation and Specification Guide

Maelstrom. Installation and Specification Guide Maelstrom Installation and Specification Guide PRODUCT DETAILS Our revolutionary Maelstrom filters set a new standard in pre-tank rainwater filtering. Filtering multiple pipes at a single point, the Maelstrom

More information

Grease Interceptors. Design & Operation. Material & Characteristics

Grease Interceptors. Design & Operation. Material & Characteristics Grease Interceptors Dormont offers a full line of grease interceptors for installation on cooking/prep sinks, pot, pan & scullery sinks and dishwasher applications. Dormont offers a variety of interceptor

More information

March, 2017 Nova Scotia On-site Sewage Disposal Systems Standard revisions effective May 1, Appendix C Falling head permeameter

March, 2017 Nova Scotia On-site Sewage Disposal Systems Standard revisions effective May 1, Appendix C Falling head permeameter Table of contents Appendix C Detailed Cross drawings Appendix D Falling head permeameter Appendix C Falling head permeameter Appendix D Detailed Cross drawings Reduce confusion related to appendix C labeling.

More information

Below ground System of pipework required to carry waste fluids from building to disposal site.

Below ground System of pipework required to carry waste fluids from building to disposal site. 1 Below ground System of pipework required to carry waste fluids from building to disposal site. Disposal site County Council sewage treatment facility. Septic tank system or alternative systems 2 1. Layout

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS INTERIM GUIDE CRITERIA FOR AEROBIC BACTERIAL GENERATOR FOR INSERT INTO SEPTIC TANKS, GREASE INTERCEPTORS AND GREASE TRAPS IAPMO IGC 180-20023

More information

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems SECTION 02607-1 1.0 GENERAL 1.1 SCOPE: A. This section covers the work necessary for the construction of sanitary and storm system manholes, catch basins, and miscellaneous concrete structures complete.

More information

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals.

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals. Page 221429-1 SECTION 221429 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

B. Wiring Diagrams: For power, signal, and control wiring.

B. Wiring Diagrams: For power, signal, and control wiring. Page 221429-1 SECTION 221429 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

GBHF Submittal Special Precautions Specifications Installation Application Specific Details

GBHF Submittal Special Precautions Specifications Installation Application Specific Details Submittal Special Precautions Specifications Installation Application Specific Details 68" (1,27 (172 cm) mm 13½" (343 cm) mm) 51½" (1,308 (131 cm) mm) 38" (965 (97 cm) SUBMITTAL 33½" (851 cm) mm) STANDARD:

More information

Assembly and Installation Instructions Grease Separator KLsepa.pop

Assembly and Installation Instructions Grease Separator KLsepa.pop Assembly and Installation Instructions Grease Separator KLsepa.pop It is imperative to observe the items described in these instructions. In case of noncompliance, all warranty claims shall lapse. For

More information

GB-50. Submittal Special Precautions Specifications Installation Application Specific Details

GB-50. Submittal Special Precautions Specifications Installation Application Specific Details Submittal Special Precautions Specifications Installation Application Specific Details 37" (94.0 cm) 10½" (26.7 (27 cm) 28½" (72.4 cm) (46.7 (45.7 cm) 28" (71.1 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet

More information

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. SECTION 33 05 13 MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. B. Related Sections: 1. Section 03 20 00 - Concrete

More information

Labko FRW Basic flow regulation well

Labko FRW Basic flow regulation well www.wavin-labko.fi WAVIN-LABKO OY Labkotie 1 FIN-36240 KANGASALA Tel: +358 (0)20 1285 210 Fax: +358 (0)20 1285 280 E-mail: tanks@wavin-labko.fi 06/09 Labko FRW Basic flow regulation well Installation,

More information

Industrial Pretreatment Program Grease Abatement Requirements for Food Service Establishments (FSEs)

Industrial Pretreatment Program Grease Abatement Requirements for Food Service Establishments (FSEs) Public Works Department Environmental Division Industrial Pretreatment Program Meridian City Hall, Suite 204 33 E Broadway Avenue Meridian, Idaho 83642 Industrial Pretreatment Program Grease Abatement

More information

TYPE "A" CATCH BASIN

TYPE A CATCH BASIN 27" 1.67' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3250-BV OR APPROVED EQUAL. "INFI SHIELD" SEAL OR APPROVED EQUAL RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE,

More information

401 Sanitary Sewer System Design Criteria. The following additional design requirements shall also apply:

401 Sanitary Sewer System Design Criteria. The following additional design requirements shall also apply: SECTION 400 SANITARY SEWER SYSTEM The design of sanitary sewers shall be in conformance with the applicable sections of the State of Washington, Department of Ecology manual, Criteria for Sewage Works

More information

GB-75. Submittal Special Precautions Specifications Installation Application Specific Details

GB-75. Submittal Special Precautions Specifications Installation Application Specific Details Submittal Special Precautions Specifications Installation Application Specific Details 38½" 38.5" (97.8 cm) 12½" (31.7 cm) 26" (66.0 cm) 46" 33½" 32" (851 (81.3 mm) cm) SUBMITTAL STANDARD: 4" plain end

More information

Ohio Administrative Code Tanks, pumps and controls, and building sewers

Ohio Administrative Code Tanks, pumps and controls, and building sewers Ohio Administrative Code 3701-29-12 Tanks, pumps and controls, and building sewers All septic tanks, dosing tanks, pump vaults, holding tanks and privy vaults, even grease traps must be water tight and

More information

4 ft. and 6 ft. Downstream Defender Handling and Installation Instructions

4 ft. and 6 ft. Downstream Defender Handling and Installation Instructions 4 ft. and 6 ft. Downstream Defender Handling and Installation Instructions Page 2 Materials Supplied By Hydro International Ledger Angle (x4) Top Slab Top Riser Benching Skirt 4ft./6ft. Downstream Defender

More information

Limestone County Water & Sewer Authority

Limestone County Water & Sewer Authority Limestone County Water & Sewer Authority DESCRIPTION: Fats, Oils, & Grease Policy POLICY NO.: 2009- EFFECTIVE: APPROVED: This Limestone County Water and Sewer Authority Fats, Oils & Grease (FOG) Policy

More information

Septic Tanks: The Primary Treatment Device of Conventional Septic Systems

Septic Tanks: The Primary Treatment Device of Conventional Septic Systems Septic Tanks: The Primary Treatment Device of Conventional Septic Systems Yvonne A. Wood and Brad D. Lee Introduction Septic tanks play an essential role in effectively treating wastewater in areas without

More information

Installation Guide Trade Waste Products

Installation Guide Trade Waste Products Installation Guide Trade Waste Products Given the large range of trade waste products, there are various standard installation instructions for our products. All trade waste products are delivered to site

More information

THIS IS A COURTESY COPY OF THIS RULE. ALL OF THE DEPARTMENT S RULES ARE COMPILED IN TITLE 7 OF THE NEW JERSEY ADMINISTRATIVE CODE.

THIS IS A COURTESY COPY OF THIS RULE. ALL OF THE DEPARTMENT S RULES ARE COMPILED IN TITLE 7 OF THE NEW JERSEY ADMINISTRATIVE CODE. (f) The minimum requirements for construction, materials and foundations of grease traps shall be the same as those required for septic tanks, as prescribed in N.J.A.C. 7:9A-8.2. (g) The inlet and outlet

More information

Section 4 Service Lines

Section 4 Service Lines Section 4 Service Lines A. General 1. A service line is that portion of a sanitary sewer line that extends from the outer building wall or foundation wall to its connection with the sewer lateral at the

More information

6 Wastewater. Renovation/retrofit set and Page 280 OEM original equipment set InnoClean PLUS. for concrete tanks

6 Wastewater. Renovation/retrofit set and Page 280 OEM original equipment set InnoClean PLUS. for concrete tanks InnoClean PUS Page 273 27 wastewater Small sewage treatment plants using the activated sludge principle (SR) Renovation/retrofit set and Page 280 OEM original equipment set InnoClean PUS for concrete tanks

More information

Ellis County Environmental Office

Ellis County Environmental Office Ellis County Environmental Office 718 Main Lower Level, Hays, KS 67601 P (785) 628-9449 F (785) 628-9448 E karen@ellisco.net W ellisco.net ELLIS COUNTY Wastewater Construction Procedures 1. Contact the

More information

LIPUMAX GREASE SEPARATOR

LIPUMAX GREASE SEPARATOR ACO Passavant Installation guide LIPUMAX GREASE SEPARATOR AUTHOR Kate Jennings DATE COMPLETED 8 August 2016 v14 ACO Polycrete, 134-140 Old Bathurst Road, Emu Plains, NSW 2750 Tel: +61 2 4747 4000 Fax:

More information

Vortex Filters. Conservation Technology

Vortex Filters. Conservation Technology Vortex Filters Vortex Filters are high-rate mechanical filters designed to extract organic debris and particulates from either rooftop or surface rainwater. They can be installed underground using an that

More information

POLYLOK / ZABEL PRODUCT BROCHURE v.3

POLYLOK / ZABEL PRODUCT BROCHURE v.3 POLYLOK / ZABEL PRODUCT BROCHURE v.3 Heavy Duty Trench Drain (Black, Grey, Green, Tan & Ductile ) 3, 4, 6, 8, 10 & 12 Black & Green Pipe s Flow Gate 12 Polylok & Pipe Adapter Ring x3 / Pan x2 & 24 x2 X-Chairs

More information

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL Before installation these instructions must be fully read and understood 3600B 3650B DISCLAIMER OF WARRANTIES The contract between Varec Vapor Control Inc. and our customer states Varec Vapor Control Inc.

More information

Manual - Part 2 - Materials

Manual - Part 2 - Materials Manual - Part 2 - Materials Chapter 1. On-Site Wastewater Manual Part 2 Materials Manual Part Two ** Page 1 Building Sewer Part Two: Materials The building sewer must be constructed with materials in

More information

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid Section I: Castings and Aluminum Covers I 1 I 2 I 3 I 4 Valve Boxes Service Clean-out Box and Lid Manhole Casting/ Standard Ring and Cover Access Covers/ Aluminum 1 I 1 VALVE BOXES: Valve boxes shall meet

More information

Date: 13/04/2015 1:14:38 PM

Date: 13/04/2015 1:14:38 PM Date: 13/04/2015 1:14:38 PM Cad File No: J:\500-Cad-data\Standard_Drawings\Flow Systems\FSI-1000-FS_On-Lot Infrastructure Installation Set Out Details.dwg Date: 25/02/2015 11:18:14 AM Cad File No: J:\500-Cad-data\Standard_Drawings\Flow

More information

SEPTIC TANK CONSTRUCTION GUIDELINES

SEPTIC TANK CONSTRUCTION GUIDELINES SEPTIC TANK CONSTRUCTION GUIDELINES Septic tank for this airport will be designed/ built by the general contractor of the building facilities. At the time of the project design, availability of a septic

More information

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

ONE PIPE LENGTH MAX (REFER TO 1/4/FT SLOPE (MIN) 5'-0 (MIN) OR 4 LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4x6 REFER TO TYPICAL EXCAVATION, VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE

More information

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms. PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

24" (STD) 36" (LARGE) SEE NOTE #6 AND #7 2" MIN FDOT 57 STONE NOT TO SCALE INSIDE WALL PRE-PRIMED JOINT SURFACES COMPLETED JOINT WITH SQUEEZE-OUT

24 (STD) 36 (LARGE) SEE NOTE #6 AND #7 2 MIN FDOT 57 STONE NOT TO SCALE INSIDE WALL PRE-PRIMED JOINT SURFACES COMPLETED JOINT WITH SQUEEZE-OUT SET COVERS FLUSH IN PAVED AREAS INSERTS PER USSM SECTION 510 PART 5J FRAMES BEDDED IN MORTAR MANHOLE FRAME & COVER AT FINISH GRADE 21" 2 COURSES OF BRICK (MIN) 4 COURSES (MAX) OR 1 HDPE ADJUSTING RING

More information

Pumper/Service Provider/Septic Technician/Service Technician/Septic Tank Service Provider/Septic Tank Service Technician Need to Know

Pumper/Service Provider/Septic Technician/Service Technician/Septic Tank Service Provider/Septic Tank Service Technician Need to Know Pumper/Service Provider/Septic Technician/Service Technician/Septic Tank Service Provider/Septic Tank Service Technician Need to Know I. The professional will understand the various techniques and responsibilities

More information

NELSON CITY COUNCIL INFRASTRUCTURAL ASSETS SD 601 APPROVED SENIOR EXECUTIVE INFRASTRUCTURE

NELSON CITY COUNCIL INFRASTRUCTURAL ASSETS SD 601 APPROVED SENIOR EXECUTIVE INFRASTRUCTURE SENIOR EXECUTIVE INFRASTRUCTURE DATE SD 601 SENIOR EXECUTIVE INFRASTRUCTURE DATE SD 602 SENIOR EXECUTIVE INFRASTRUCTURE DATE SD 603 SENIOR EXECUTIVE INFRASTRUCTURE DATE SD 604 NOTES 1. PRE-FORMED PLASTIC

More information

D. Encase exterior cleanouts in concrete with access cover installed flush with grade.

D. Encase exterior cleanouts in concrete with access cover installed flush with grade. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Existing System Evaluation Report for Onsite Wastewater Systems

Existing System Evaluation Report for Onsite Wastewater Systems Existing System Evaluation Report for Onsite Wastewater Systems State of Oregon Department of Environmental Quality Onsite Program 165 East 7 th Avenue, Suite 100 Eugene, Oregon 97401 For more information,

More information

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL Before installation these instructions must be fully read and understood 2010B 3500B 2020B The VAREC Vapor Control Inc. 2010B/2020B/3500B Series pressure and/or vacuum relief valves have not been tested

More information

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING STANDARD CONSTRUCTION DETAILS REVISED MARCH 2018 GENERAL NOTES EMBEDMENT DETAILS EMBEDMENT DETAILS TWO-WAY CLEANOUT - EXISTING LATERAL TWO-WAY CLEANOUT - NEW CONSTRUCTION TYPICAL SEWER HOUSE SERVICE CONNECTION

More information

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS UTAH COUNTY HEALTH DEPARTMENT Div. of Environmental Health 151 South University Avenue, Provo 84601 (801) 851-7525 FAX 851-7521 GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS This is intended to

More information

3ft, 4 ft., 6 ft., and 8 ft. First Defense HC Handling and Installation Instructions

3ft, 4 ft., 6 ft., and 8 ft. First Defense HC Handling and Installation Instructions 3ft, 4 ft., 6 ft., and 8 ft. First Defense HC Handling and Installation Instructions Page 2 Materials Supplied By Hydro International 3 ft./ 4 ft./ 6 ft./ 8 ft. diameter top slab 3 ft./ 4 ft./ 6 ft./ 8

More information

16. Design of Pipeline Structures.

16. Design of Pipeline Structures. 16. Design of Pipeline Structures. a. General. 1) The following guidelines are for the design of structures for water and sewer pipelines including structural concrete and miscellaneous metals design.

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

NON-ELECTRIC SEPTIC SYSTEMS

NON-ELECTRIC SEPTIC SYSTEMS BIOROCK S NEW GENERATION NON-ELECTRIC SEPTIC SYSTEMS ALL-IN-ONE COMPACT SOLUTIONS FOR DOMESTIC WASTEWATER TREATMENT Non-Electric Septic Systems MONOBLOCK THE ALL-IN-ONE COMPACT SOLUTION TIPPING TRAY GREEN

More information

NOWRA s Onsite A to Z SEPTIC TANKS. Model Decentralized Wastewater Practitioner Curriculum

NOWRA s Onsite A to Z SEPTIC TANKS. Model Decentralized Wastewater Practitioner Curriculum NOWRA s Onsite A to Z SEPTIC TANKS Model Decentralized Wastewater Practitioner Curriculum A Cooperative Effort These materials were originally developed by the Consortium of Institutes for Decentralized

More information

Sag Pipe (depressed sewers, or Inverted siphons) Dr. Sataa A. Al-Bayati(10-11)

Sag Pipe (depressed sewers, or Inverted siphons) Dr. Sataa A. Al-Bayati(10-11) بسم هللا الرحمن الرحيم Sag Pipe (depressed sewers, or Inverted siphons) Dr. Sataa A. Al-Bayati(10-11) A sewer that drops below the hydraulic gradient to pass under an obstruction, such as a railroad cut,

More information

SPECIAL SPECIFICATION 3504 Septic Tank System

SPECIAL SPECIFICATION 3504 Septic Tank System 1993 Specifications CSJ s 3136-01-126, etc. & 0683-01-070, etc. SPECIAL SPECIFICATION 3504 Septic Tank System 1. Description. This Item shall govern for all materials, equipment and labor necessary for

More information

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures A Delivering Reliability Electrical Vaults Power & Energy-Underground Structures A The Benefits of Precast Vaults Electrical vaults house power cables and transformers, and are a preferred alternative

More information

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE PART 1 GENERAL 1.1 WORK INCLUDED Specifies requirements for construction and performance of an underground stormwater quality

More information

Mueller Gas Products. Mueller No Blo Service Tee H17500 o ¾ x ¾, 1 x 1, 1 1/4 x 1 1/4, 2 x 2 o 250 PSIG H17502 o 2 x 2

Mueller Gas Products. Mueller No Blo Service Tee H17500 o ¾ x ¾, 1 x 1, 1 1/4 x 1 1/4, 2 x 2 o 250 PSIG H17502 o 2 x 2 Mueller Gas Products Distributed by: Mountain States Pipe and Supply Colorado Springs, Colorado 80903 1 800 777 7173 Mueller No Blo Service Tee H17500 o ¾ x ¾, 1 x 1, 1 1/4 x 1 1/4, 2 x 2 o 250 PSIG H17502

More information

Installation Procedure FP McCann DN1050 Easi-Pit

Installation Procedure FP McCann DN1050 Easi-Pit Installation Procedure FP McCann DN1050 Easi-Pit This document describes the recommended procedure for the installation of FP McCann Easi- Pit DN1050 Precast Concrete Catch-Pit, used in manhole construction

More information

A. This Section includes gravity-flow, nonpressure storm drainage outside the building, with the following components:

A. This Section includes gravity-flow, nonpressure storm drainage outside the building, with the following components: SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.I RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Current Standard Plates including Transmittal Letters are available on the web at:

Current Standard Plates including Transmittal Letters are available on the web at: MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (6-03) MANUAL: Standard

More information

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms. SECTION 22 13 00 FACILITY SANITARY SEWERAGE PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE

STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE PART 1 GENERAL 1.1 WORK INCLUDED This section specifies requirements for constructing underground stormwater treatment

More information

PRECAST CONCRETE ON-SITE WASTEWATER TANKS

PRECAST CONCRETE ON-SITE WASTEWATER TANKS PRECAST CONCRETE ON-SITE WASTEWATER TANKS OUTLINE Purpose Precast Advantage Design Goals Applicable Standards Structural Design Materials Production Watertightness Installation NPCA Plant Certification

More information

3/23/2016. Happy Pi Day! What We Will Discuss. Best Practices for Precast Concrete Tank Inspections

3/23/2016. Happy Pi Day! What We Will Discuss. Best Practices for Precast Concrete Tank Inspections Best Practices for Precast Concrete Tank Inspections 29 th Annual GSDI Spring Septic System Conference & Expo Monday March 14, 2016 Claude Goguen, PE, LEED AP, National Precast Concrete Association Happy

More information

PLUMBING BUILDING SCOPE OF WORK

PLUMBING BUILDING SCOPE OF WORK PLUMBING BUILDING SCOPE OF WORK 1. The Contractor shall furnish all supervision, materials, labor, equipment, tools, supplies, incidental items, including construction cleanup, etc for accomplishing the

More information

100' MAXIMUM DETAIL NOTES: INSTALL 6" MINIMUM PIPE SIZE IN R.O.W. INSTALL 6" CLEANOUT PER STD DETAIL 606.

100' MAXIMUM DETAIL NOTES: INSTALL 6 MINIMUM PIPE SIZE IN R.O.W. INSTALL 6 CLEANOUT PER STD DETAIL 606. MAX. 5 C.O. CLEAN OUT REQUIRED AT ALL ANGLE POINTS OVER 5 5' MAXIMUM.MATERIAL LIST: IF GREATER THAN 5', INSTALL ADDITIONAL CLEAN OUT BUILDING CONNECTION. MAX. 5 6" MIN. 5 NOTES: BUILDING.. SEE SECTION

More information

Is this the best OSD system ever?

Is this the best OSD system ever? Is this the best OSD system ever? 1. You may not even need a costly traditional OSD system at all. Use our Landscape Tanks as your Structural Retaining Wall, Front Fnce, Pool or Pergola Surround and you

More information

HOLDING TANK PLANNING & INSTALLATION GUIDELINES

HOLDING TANK PLANNING & INSTALLATION GUIDELINES HOLDING TANK PLANNING & INSTALLATION GUIDELINES Under no circumstances is sewage from a holding tank to be discharged onto the surface of the ground or into groundwater or surface waters. TABLE OF CONTENTS

More information