HIGH PRESSURE FI TERS HPM SERIES 420 BAR
|
|
- Gillian Bruce
- 6 years ago
- Views:
Transcription
1 HIGH PRESSURE FI TERS HPM SERIES 4 R HPM is the high pressure filter up to 4.. Pa (4 bar- Psi); the range is composed by different sizes with nominal flow rates up to 4 l/min., available with threaded or flanged connections. Filter elements are made with the most advanced materials, as a guarantee for an high filtration efficiency and a long-lasting life. HPM series modular construction allows the customer to choose the most suitable type following his needs. OMT Research & Development Department is constantly making a check about filter and elements performances. Visual indicator Plug Visual el. Reed indicator Visual el. indicator Filter head Plug y-pass valve Filter element Seals Filter bowl 84
2 TECHNIC DT HPM FILTER SERIES IS SUITLE TO THE FOLLOWING ISO STNDRDS: -ISO 94 - Hydraulic fluid power - Filter elements Verification of collapse / burst resistance -ISO 94 - Hydraulic fluid power - Filter elements Verification of fabrication integrity and determination of the first bubble point -ISO 94 - Hydraulic fluid power - Filter elements Verification of material compatibility with fluids -ISO 7 - Hydraulic fluid power - Filter elements Method for end load test -ISO 74 - Hydraulic fluid power - Filter elements Verification of flow fatigue characteristics MTERILS (housing) Head owl Seals y-pass valve Reverse flow valve Indicator Cast iron Steel or cast iron N: una-n V: Viton rass Steel rass WORKING CONDITIONS -ISO 98 - Hydraulic fluid power - Filters - Evaluation of pressure drop versus flow characteristics -ISO Hydraulic fluid power - Filters - Multi-pass method for evaluating filtration performance of a filter element MTERILS (filter elements) Plates Support tube Support mesh Galvanized steel Galvanized steel Galvanized steel with epox coating Filter pressure Operating pressure Collapse pressure y-pass valve setting pressure Compatibily with hydraulic fluids ISO 94 Working pressure: 4.. Pa (4 bar) Testing pressure:.. Pa ( bar) Collapse pressure:.. Pa ( bar) - a +9 o c X series :.. Pa ( bar) Y series :.. ( bar) bar ±% (from opening) Compatible with mineral oils such as HH,HM,HR,HV,HG according to ISO 74/4) FILTRTION MTERILS Filter elements Description Material Filtration (µm) ß Ratio ISO 47 ßx ISO 889 ßx(c) Inorganic fibre Glass fibre Inorganic fibre Glass fibre Inorganic fibre Glass fibre 9 Inorganic fibre Glass fibre T Wire mesh Inox (aisi 4) - - T Wire mesh Inox (aisi 4) - - C Treaded paper Cellulose fibre - - C Treaded paper Cellulose fibre - - FILTRTION RE (cm ) FILTER ELEMENTS SERIES X - P.. Pa ( bar) Filter elements CHP8 CHP8 CHP8 CHP4 CHP4 CHP CHP CHP CHP T - T C - C FILTRTION RE (cm ) FILTER ELEMENTS SERIES Y - P.. Pa ( bar) Filter elements CHP8 CHP8 CHP8 CHP4 CHP4 CHP CHP CHP CHP T - T
3 8 Flows have been calculated just in order to obtain a pressure drop p. Pa (. bar) With mineral oil kinematic viscosity cst and 8 kg/m density. (See remarks on page 9-9) 8 THREDED CONNECTIONS Tipo / Type E (depth mm) / SP /4 SP / NPT /4 NPT SE8 - /4 -UNF SE - / - UN / SPT /4 SPT / UNC / UNC / UNC / UNC LENGTHS H Type H (mm) Length OMT/Pall HPM8.. HPM8.. HPM8.. RECOMMENDED FLOWS (Glass fibre elements) HPM Elemento filtrante Replace element Portata (L/min) serie X X series Portata (L/min) serie Y Y series Peso (Kg) Weight (Kg) ø7 E CH ,8,8,8,8 4, 4, 4, 4,, 8
4 4 H 7HPM 4 Flows have been calculated just in order to obtain a pressure drop p. Pa (. bar) With mineral oil kinematic viscosity cst and 8 kg/m density. (See remarks on page 9) THREDED CONNECTIONS Tipo / Type E (depth mm) 4 4 /4 SP SP /4 NPT NPT SE - / -UN SE - / -UN /4 SP /4 SPT SPT /4 SPT /4 NPT M M FLNGED CONNECTIONS Type Connection I M G E (depth mm) /4 SE - PSI/M SE - PSI/M /4 SE - PSI/UNC SE - PSI/UNC /4 SE - PSI/M /4 SE - PSI/UNC M M M M M M I LENGTHS CH ø78 Type H (mm) 77 9 Length OMT HPM4.. HPM4.. Lunghezza Pall Length Pall HPM4.. HPM44.. RECOMMENDED FLOWS (Glass fibre elements) HPM Replace element X series Y series Weight (Kg) E ,8,8,8,8 8,9 8,9 8,9 8,9 87
5 Flows have been calculated just in order to obtain a lpressure drop p. Pa (. bar) With mineral oil kinematic viscosity cst and 8 kg/m density. (See remarks on page 9) 4 Tipo / Type THREDED CONNECTIONS SP /4 SP / SP NPT /4 NPT / NPT SE - /8 - UN SE4-7/8 - UN SPT /4 SPT / SPT E (prof. mm) E (depth mm) FLNGED CONNECTIONS Type ttacco-connection I M G E (depth mm) 8 9 /4 SE -PSI/M / SE - PSI/M /4 SE - PSI/UNC / SE - PSI/UNC /4 SE - PSI/M /4 SE - PSI/UNC I M M 7/ UNC M 4 H G LENGTHS Type H (mm) Length OMT Lunghezza Pall Length Pall HPM.. HPM.. HPM.. HPM4.. HPM.. HPM.. HPM7.. HPM8.. RECOMMENDED FLOWS (Glass fibre elements) CH ø HPM Replace element X series Y series Weight (Kg) 7 E ,7,7,7,7,,,,
6 REVERSE F O V VE INGRESSO IN USCIT OUT vailable for HPM models: FILTER ELEMENTS INTERCHNGELE TO PLL OMT replace elements CHP Series are perfectly interchangeable with Pall replace elements, as indicated in the following table: Pall part-number OMT part-number Pall part-number OMT part-number Pall part-number OMT part-number HC9 FKP4H FKN4H FKS4H FKT4H HC9 FKP8H FKN8H FKS8H FKT8H HC9 FDP4H FDT4H HC9 FDP8H FDT8H HC98 FKP4H FKN4H FKS4H FKT4H CHP8 XN XN XN XN CHP8 XN XN XN XN CHP8 YN YN CHP8 YN YN CHP4 XN XN XN XN HC98 FKP8H FKN8H FKS8H FKT8H HC98 FDP4H FDT4H HC98 FDP8H FDT8H HC9 FKP4H FKN4H FKS4H FKT4H HC9 FKP8H FKN8H FKS8H FKT8H CHP44 XN XN XN XN CHP4 YN YN CHP4 YN YN CHP XN XN XN XN CHP XN XN XN XN HC9 FKPH FKNH FKSH FKTH HC9 FKPH FKNH FKSH FKTH HC9 FDP4H FDT4H HC9 FDP8H FDT8H HC9 FDPH FDTH HC9 FDPH FDTH CHP7 XN XN XN XN CHP8 XN XN XN XN CHP YN YN CHP YN YN CHP7 YN YN CHP8 YN YN HPM complete filters will be supplied with the replace element and special interchangeable Pall tang, if when ordering the OMT replace element, you indicate the size of the replace element in the complete part-number. Example: 7HPM 8 XNR COMPLETE FILTER Complete OMT filter series 7HPM with replace element interchangeable to Pall HC9FKPH 89
7 Pressure Drops (according to ISO 98) The pressure drop of the complete filter is calculated by adding the pressure drop of the housing to that of the filter element. Pressure drops in the housings The graphics refer to use of mineral oil with a mass density of 8 Kg/m. The pressure drop is proportional to the variations of mass density. Pressure drops in the filter elements The graphics refer to mineral oil with a kinematic viscosity of cst. The variation of the pressure drop is proportional to viscosity. HPM series 8 P HOUSINGS Y-PSS series F series
8 (according to ISO 98) 8 series Pressure Drops (according to ISO 98) HPM series 4 P HOUSINGS Y-PSS REV. FLOW VLVE Con valvola Reverse flow series F series
9 Pressure Drops (according to ISO 98) HPM series P HOUSINGS Y-PSS REV. FLOW VLVE series portata / F portata/ series series series
10 DIFFERENTIL INDICTORS 7OMTI-VDI-F(DV) 7OMTI-DV8 (DV8) 7OMTI-VDI-G(DE) 7OMTI-DE8 (DE8) 4 7DR 7DR8 4 7 CH / SP 8 / SP CH / SP CH ø ø C ø VISUL INDICTOR ELECTRICL VISUL INDICTOR VISUL-ELECTRICL INDICTOR WITH REED CONTCTS TECHNICL DT Part number DV DE DR Description visual electrical Visual-electrical with reed contacts Setting Electrical Contacts.Pa ( bar) Switch - pplication Filters with y-pass and elements X series reakdown voltage for DR and DR 8 Feeder voltage (V).C. - D.C. - Power with inductive load (V) reakdown voltage for DE and DE 8 DV 8 DE 8 DR 8 visual electrical Visual-electrical with reed contacts 8.Pa (8 bar) Switch - Filters with y-pass and elements Y series Feeder voltage (V).C..C. D.C. D.C. D.C. D.C. Resistive load () Inductive load ().. With y-pass SIMOLOGY Without y-pass N.. N.C. /bl / br ma N.. N.C. /bl / br ma C / bk ne C / bk ne HPM...R/Q HPM...R/Q+ DV HPM...R/Q+ DE / DR HPM...S/P HPM...S/P + DV8 HPM...S/P + DE8 / DR8 9
11 HO TO ORDER THE COMP ETE FI TER 7HP X N R Nominal Size Nominal Size (4 Pall) 4 - (44 Pall) - ( Pall) - ( Pall) - (7 Pall) 4 - (8 Pall) - C* C* Filtration Element Without filtration elements µm Resin treated cellulose ßx> µm Resin treated cellulose ßx> µm Inorganic fibre ßx> µm Inorganic fibre ßx> µm Inorganic fibre ßx> X Y N V.. ( ar).. ( ar) Seals Nitrica / una-n Viton P. Cartridge for filters with y-pass for filters without y-pass T T µm µm µm Inorganic fibre ßx> Steel isi 4 Wire mesh Steel isi 4 Wire mesh S R y-pass valve Without y-pass y-pass p bar *Only X version P Q With reverse flow valve With reverse flow valve + y-pass 7CHP 4 Y N How to order the replacement element *P, Q options not valid for Pall and HPM8 versions CONNECTIONS HPM8 / SP /4 SP / NPT /4 NPT SE8 /4 - UNF SE / SPT /4 SPT HPM4 /4 SP SP /4 NPT NPT SE / - UN SE / - UN /4 SE-PSI/M SE-PSI/M /4 SE-PSI/UNC SE-PSI/UNC /4 SE-PSI/M /4 SE-PSI/UNC /4 SP /4 SPT SPT /4 SPT /4 NPT HPM SP /4 SP / SP NPT /4 NPT / NPT SE /8 - UN SE4 7/8 - UN /4 SE-PSI/M / SE-PSI/M /4 SE-PSI/UNC / SE-PSI/UNC /4 SE-PSI/M /4 SE-PSI/UNC SPT /4 SPT / SPT * See page 9 for information how to order clogging indicators 94
SERIES LMP 210. Working pressure 60 bar. Style B. Style S D.I. D.I.
0 SERIES Working pressure 60 bar Style S Style D.I. D.I. Technical data Filter housing (Materials) Head: nodised luminium Housing: nodised luminium ypass valve: Nylon Pressure Working pressure: 60 bar
More informationHD 152 HD 172 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to 190 l/min
High Pressure Filters Worldline HD HD 7 In-line mounting Operating pressure up to bar Nominal flow rate up to 9 l/min Description Application In the high pressure circuits of hydraulic systems. Performance
More informationSERIES LMP 210. Working pressure 60 bar. Style B. Style S D.I. D.I.
0 SERIES Working pressure 60 bar Style S Style D.I. D.I. Technical data Filter housing (Materials) Head: luminium Housing: nodized luminium ypass valve: Nylon Pressure Working pressure: 60 bar (6 MPa)
More informationHigh Pressure Filters Worldline 100 HD 049 HD 069. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to 27.7 gpm. 40.
High Pressure Filters Worldline 00 HD 09 HD 069 In-line mounting Operating pressure up to 9 psi Nominal flow rate up to 2. gpm 0.5-us Description Application In the high pressure circuits of hydraulic
More informationSERIES LMP 210. Working pressure 60 bar. Style B. Style S D.I. D.I.
0 SERIES Working pressure 60 bar Style S Style D.I. D.I. Technical data Filter housing (Materials) Head: luminium Housing: nodised luminium ypass valve: Nylon Pressure Working pressure: 60 bar (6 MPa)
More informationMDF. Pressure Filters MODULAR INLINE FILTER
MDF Pressure Filters MODULAR INLINE FILTER Pressure Filters MDF MDF 3,5 MPa (35 bar) Port sizes: etop 0507 Flow rates: 7 l/min TEHNIAL DATA Max. working pressure: 3,5 MPa (35 bar) Max. test pressure: 40
More informationE 444 E 454 E 464 E 644 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 680 l/min / gpm
Return Filters E E 5 E 6 E 6 Tank top mounting Connection up to SAE Nominal flow rate up to 68 l/min / 79.7 gpm Description Application In the return line circuits of hydraulic systems. erformance features
More informationE 443 E 453 E 463 E 643. Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min e
R e t u r n F i l t e rs E 443 E 453 E 463 E 643 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min 20.50-4e D e s c r i p t i o n Application In the return line circuits of hydraulic
More informationD 090 D 100 In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min
Return Filters D 9 D In-line mounting Connection up to G¾ Nominal flow rate up to l/min Description Application In the return line circuits of hydraulic systems. Performance features Protection against
More informationPRESSURE FILTERS. BYPASS VALVE Setting: 600 kpa (6 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C
COMPONENTS PB MATERIALS Head: Cast iron Bowl: Steel Bypass valve: Steel Seals: NBR Nitrile (FKM - on request fluoroelastomer) Indicator housing: Brass PRESSURE (ISO 077-:) Max. working: 4 MPa (40 bar)
More informationSuction Filter - SE. Working Temperature From -25 to +110 C. Materials. Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide
COMPONENTS Pressure (ISO 077-:00) Max working:, MPa ( bar) Test:,5 MPa (5 bar) Bursting:,5 MPa (5 bar) Collapse, differential for the filter element (ISO 9): 00 kpa ( bar) Bypass Valve Setting: 5 kpa (0,5
More informationReturn Filters D 090 D 100. In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min e
Return Filters D 9 D In-line mounting Connection up to G¾ Nominal flow rate up to l/min.5-e Description Application In the return line circuits of hydraulic systems. Performance features Protection against
More informationReturn Line Filter RFM
Return Line Filter RFM Flow rates up to 85 l/min Pressure range up to 1 bar Material: Aluminium/Steel/Synthetic material Return line filters type RFM are designed to be mounted on tank tops to filter out
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min
Return Filters E 9 E E Tank top mounting Connection up to G Nominal flow rate up to l/min Description Application In the return line circuits of hydraulic systems. Performance features Protection against
More informationBody without bypass valve. Body with 6 BAR bypass valve. ELEMENT to be added Element Filtration Size 11 Size 12 Size 13 Size 21 Size 22 FA 5 micron
Pressure (ISO 077-:) Max working: 3,5 MPa (35 bar) Test: 47 MPa (470 bar) Bursting: 95 MPa (9 bar) Collapse, differential for the filter element (ISO 94): series standard: MPa (0 bar) series H+: MPa (0
More informationHD 790 HD 990. In-line mounting Operating pressure up to 6525 psi Nominal flow rate up to 265 gpm us d
H i g h re s s u re F i l t e rs Wo r l d l i n e 4 0 0 HD 790 HD 990 In-line mounting Operating pressure up to 6525 psi Nominal flow rate up to 265 gpm 40.90-1us 30.30-2d D e s c r i p t i o n Application
More informationFiltration Guideline. Introduction. STAUFF Filtration Technology offers two publications with knowledge and expertise about
Introduction STAUFF Filtration Technology offers two publications with knowledge and expertise about the applications: A. The compact Filtration Guideline Please have a look at the following pages. B.
More informationWalter Stauffenberg GmbH & Co. KG
Return Line Filter SRFL-S/D Australia Stauff Corporation (Pty.) Ltd. P.O.Box 227, 24-2 Doyle Avenue, Unanderra Wollongong, N.S.W 252 AUSTRALIA Tel: +1 2 42 71 18 77 Fax: +1 2 42 71 84 2 Brazil Stauff Brasil
More informationMEDIUM PRESSURE FILTERS LPF Series Inline Filters 725 psi up to 74 gpm
LPF Series Inline Filters 725 psi up to 74 gpm Hydraulic Symbol A B E6 Features LPF filters are manufactured with cast aluminum head and aluminum cold formed bowls. Aluminum alloy is water tolerant - anodization
More informationProcess Inline Filter, Change-Over
Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.
More information(G) 350 bar (5080 PSI) p max
In-Line Bodies for Screw-In Cartridge Valves SB p max (AL) 50 bar (600 PSI) p max (G) 50 bar (5080 PSI) p max (ST) 40 bar (6100 PSI) Technical Features In-line bodies designed to accommodate different
More informationProserv Flushing Unit - Offshore
Flushing Services PRODUCTION Proserv Flushing Unit - Offshore Proserv offers a wide range of various flushing units with diesel-engine drive and electrical drive options for sale and hire. We have different
More informationFILTRATION TECHNOLOGY STAUFF. Return Line Filters SRFL-S & SRFL-D. Quality and Service Worldwide
FILTRATION TECHNOLOGY 2 STAUFF Return Line Filters SRFL-S & SRFL-D Quality and Service Worldwide Return Line Filter SRFL-S/D Australia Stauff Corporation (Pty.) Ltd. P.O.Box 227, 24-2 Doyle Avenue, Unanderra
More informationACCESSORIES LS/520, LC/520 Heavy duty non-return valves 1/ LT1000 Block form flow regulators (uni-directional) 1/8 & 1/4
ESSORIES LT000 lock form flow regulators (uni-directional) /8 & /4 LT00 lock form flow regulators (bi-directional) /8 & /4 LT70 Quick exhaust valves /8 & /4 LS/50, L/50 Heavy duty non-return valves /4...
More informationFiltration for Improved Bearing and Equipment Life Filtration for Improved Bearing and Equipment Life
Filtration for Improved Bearing Martin Williamson KEW Engineering Ltd. Bearings can have an infinite life when particles larger than the lubricant film are removed. SKF 2 3 4 Case Studies & Successes Nippon
More informationFILTERS. COMPO CARE - Pressure filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES
ILTERS HYDRAULI DIVISIO - Pressure filters TEHIAL DATA ORDERIG AD OPTIOS RT LOGGIG IDIATORS PRESSURE DROP ( p) URVES PRESSURE DROP ( p) URVES - MEDIA H+ ROSS UTIOAL VIE SPARE PARTS ORDERIG IORMATIO DIMESIOS
More informationAir Cooler Industry OSCA / OSCAF 0-3
Cooler Industry OSC / OSCF 0- Symbol General The low noise coolers of OSC / OSCF series are mostly used in small and medium hydraulic systems. Compact and efficient they offer high performance with a low
More informationHigh Pressure Filter Assemblies
High Pressure Filter Assemblies Up to 20,000 PSI (1378 bar) All stainless steel construction Stainless steel metal felt filter elements High Pressure T-Type Filter Assemblies Greater service life than
More informationOHF 1120 HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999
OHF 1120 FILTRATIO I BRIEF Contamination Control in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further
More informationIon exchange Unit IXU 1/4 Series
Ion exchange Unit IXU 1/4 Series Description The IXU series of easy-maintenance ion exchange units is designed to condition fire-resistant hydraulic and lubrication fluids based on phosphate esters (HFD-R)
More informationMEDIDOR DE VAZÃO TIPO ENGRENAGENS PARA LIQUIDOS VISCOSOS SERIE DZR COM ENGRENAGENS CILINDRICAS
MEDIDOR DE VAZÃO TIPO ENGRENAGENS PARA LIQUIDOS VISCOSOS Measuring range:.- to 1-5 L/min Measuring accuracy: ±.3 up to ±1 % of actual flow pmax: bar tmax: 15 C Process connection: G 1, G 3, G 1, G 1 female
More informationZDM POSITIVE DISPLACEMENT FLOW METER
ZDM POSITIVE DISPLACEMENT FLOW METER Flow Pressure Level Temperature Measurement Monitoring Control Viscosities up to 100,000 cst Accuracy: ±0.3% of Flow To 6500 PSIG Pressure Can Detect Flow Direction
More informationRotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions
process measurement solutions 3 Rotameter Series 3 glass tube variable area flowmeter Data sheet 70 A range of quality glass tube V.A. flowmeters for general purpose & industrial applications Robust construction
More informationOffLine Filter OLF 5
+ (0)120 6 OffLine Filter OLF Description The OLF and 10 series of filters are used for the offline, fine filtration of hydraulic oils. The series comprises numerous versions, for example with or without
More informationFILTERS. COMPO CARE - Pressure filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW
ILTERS HDRAULI DIVISIO OMO ARE - ressure filters D TEHIAL DATA ORDERIG AD OTIOS RT LOGGIG IDIATORS RESSURE DRO ( p) URVES ROSS UTIOAL VIEW SARE ARTS ORDERIG IORMATIO DIMESIOS O THE ILTER ELEMET ILTERS
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 203 PERFORMANCE CURVE VOX 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW
More information12D SERIES THREE SCREW PUMPS ROTARY SCREW PUMPS
TM 12D SERIES THREE SCREW PUMPS ROTARY SCREW PUMPS The reliable pump people Performance Shown at 2000 PSID (138 BAR), 200 SSU (43 CST) 60 HZ: 870 1150 1750 3500 *Bi-metal construction only 50 HZ: 960 1450
More informationSolenoid valve 2/2 way N.O. With pilot control
Solenoid valve 2/2 way N.O. With pilot control 21W3Z190 21W7Z500 PRESENTTION: S.V. with pilot control for interception of fluids compatible with the construction materials. minimum operational pressure
More informationPage - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB
SUBMERSIBLE MULTISTAGE PUMPS SB 3 CONTENENTS 50 Hz Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB 3 15-23-30-45 203 - CONSTRUCTIONS
More informationSITRANS P measuring instruments for pressure
Overview Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80x10x60 (3.15x4.7x.36) Screw terminals (Pg 13.5 cable inlet) or Han
More informationZDM. Positive Displacement Flowmeter
Positive Displacement Flowmeter measuring monitoring analyzing ZDM Viscosities up to 100,000 cst Accuracy: ±0.3% of Flow Pressure: to 6500 PSIG Can Detect Flow Direction Handles a Variety of Lubricating
More informationSITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview
Overview Design and operation The main components of the Tubux variable area meters are the glass variable-area flow tube with float, the fitting and the connection parts. The flow is displayed directly
More informationFN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring
Level Measurement and Monitoring FN04 Liquid level sensor with continuous detection Level measurement unaffected by foam formation, conductivity, pressure or temperature Remote indication over very long
More informationUnloading Valve Series R4U
Characteristics Series RU Subplate mounted unloading valves series RU are used to unload a circuit at low pressure. The mechanically adjustable pressure signal to unload the main stage has to be applied
More information- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202-203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300-301 QUANTITY FOR
More informationVARIABLE AREA FLOWMETER EASYFLOW.
VARIABLE AREA FLOWMETER EASYFLOW www.sedflowcontrol.com EASYFLOW APPLICATIONS Monitoring of the flow of concentrate and recirculation of a Reverse Osmosis Water Treatment Plant Reverse Osmosis System Water
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING
More informationCompressed Air Systems. Compressed Air Filters. Balston Microfiber Filter Assemblies. Product Features
Compressed Coalescing Balston Microfiber Filter Assemblies Balston Coalescing Compressed protect your equipment and delicate instruments from the dirt, water, and oil usually found in compressed air. Balston
More informationPRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.
PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts
More informationEBS Filters. The largest automatic self-cleaning filter for fine filtration. features: up to 7200 m³/h (32000 US gpm) less than 1% of the total flow
EBS Filters flow rates filtration degrees water for cleaning min. operating pressure up to 7200 m³/h (32000 US gpm) 800-10 micron less than 1% of the total flow 2 bar (30 psi) The largest automatic self-cleaning
More informationD-35 Series. Up to 37 gpm (140 l/min) D-35 Specialized Designs
D-35 Series Up to 37 gpm (14 l/min) D-35 Specialized Designs Hydra-Cell Slurry Duty pumps are specifically designed for abrasive slurry applications. See page 72 for complete specifications. The D-35 Hydra-Cell
More informationStandard Screens. Sizes, Materials and Pressure Ratings. How To Order BT150SS P. BF-Cast Iron. BF-Stainless Steel.
n Ounce of Prevention is Worth the Price of a Strainer! HRT INDUSTRIL BSKET STRINERS are used to protect sensitive downstream equipment from damage and premature wear by removing unwanted solids from process
More informationFiltration Solutions. In Naval Applications. Clean Fluids. Keep Running.
Filtration Solutions In Naval Applications Clean Fluids. Keep Running. Proven Solutions for Protecting Critical Shipboard Systems At Donaldson we are the acknowledged industry leader in the design, development
More informationPARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )
PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300
More informationRosemount 1154 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10
More informationMaterials : Carbon steel or Stainless steel MERXTRADE BV.
ADE B.V. Size : DN 1/4 to DN 2 Ends : Threaded female BSP, NPT or S.W. Min Temperature : - 30 C in S.S. and - 20 C in carbon steel Max Temperature : + 180 C Max Pressure : 138 Bars (Class 800) Specifications
More informationHousings & Accessories
HYDRA FORCE Housings & Accessories HydraForce offers standard cartridge valve housings and custom integrated circuit manifolds in aluminum, ductile iron, and steel. ALUMINUM HOUSINGS: Standard high tensile
More informationTip. For detailed information on the motors please refer to pages
48 49 We select the materials with regard to the liquids to be pumped. Both the pump tube models feature an extremely resistant pure carbon bearing and there are no grease fillings in the shaft tube, so
More informationCATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.
CATALOG Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. APPLICATIONS Monitoring of the flow of concentrate and recirculation of a reverse osmosis water treatment plant Reverse Osmosis System Water
More informationWater Cooled Oil Cooler
Water Cooled Oil Cooler HOW Series Iron particle type: HOWF series FH Copper particle type: HOW series HOW Series Heat transfer area (Inside pipe) (m ) Heat exchange (kw) Flow rate (L/min) Oil side side
More informationRosemount 1152 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment
More informationWEGO3 Cooling and filter system
The Professional Choice in Fluid Management WEGO3 Cooling and filter system The Olaer Group is a global player specialising in innovative, efficient system solutions for temperature optimisation and energy
More information"PV2R24A/34A" Series Double Vane Pumps
"PVR4/34" Series Double Vane s These double pumps incorporate the new PVR4 series pumps for the large volume side, a feature that permits discharge to separate circuits. Graphic Symbol Number ation F-
More information- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 203 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE
More informationFILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW
IL HYAULI IVIIO uction filters HIAL AA OIG A OPIO HA LOGGIG IIAO PU OP ( p) UV O UIOAL VI PA PA OIG IOAIO IIO O H IL L IL HYAULI IVIIO UIO IL 4 31 ø 4.96 ø 5 AIAL over & head (41) Aluminium alloy owl (41)
More informationBEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103
CONTENTS -SPECIFICATIONS Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 -PERFORMANCE CURVES Performance Curve Best One 200 Performance
More informationDrain Taps, Gland Cocks, De-Aerators and Air Vents
SETION 11a Drain Taps, Gland ocks, De-erators and ir Vents Tel: + ()195 71 Fax: + ()195 71 Email: sales@hattersley.com export@hattersley.com www.hattersley.com ontents Drain Taps, Gland ocks, De-erators
More informationPAHT C pumps ATEX PAHT C pump
MAKING MODERN LIVING POSSIBLE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet ATEX PAHT C pump hpp.danfoss.com Table of Contents 1. Introduction...2 2.
More informationSpare List SPL/266XXX-EN Rev. B. Models 266XXX spare parts list. 2600T Series Pressure Transmitters Engineered solutions for all applications
Spare List SPL/266XXX-EN Rev. B Models 266XXX spare parts list 2600T Series Pressure Transmitters Engineered solutions for all applications Models 266XXH DP style transmitter with barrel housing 6 0 9
More informationCATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.
CATALOG Variable Area Flowmeter EASYFLOW www.sedflowcontrol.com SMART IN FLOW CONTROL. Easyflow Applications Monitoring of the flow of concentrate and recirculation of a Reverse Osmosis Water Treatment
More informationDifferential pressure
Differential pressure 228 Overview Differential pressure 230 VEGADIF 65 232 Chemical seal 236 Oval flange adapter, mounting bracket, cutting ring screwing 238 Valve block 227 Overview Differential pressure
More informationLutz Flow Meter Program
Lutz Flow Meter Program A flexible friend: Lutz flow meter TS Mixing and Matching: The modular flow meter system TS offers almost unlimited application possibilities. You are free to select the basic meter,
More informationSelection Chart Solenoid valves
894434 Version 09/2017 Print 09/2017 Christian Bürkert GmbH & Co. KG Selection Chart Solenoid valves Bürkert Fluid Control Systems Christian-Bürkert-Straße 13-17 74653 Ingelfingen Deutschland Tel.: +49
More informationUFR+L FILTER REGULATOR + LUBRICATOR
FEATURES The UFR+L filter regulator + lubricator is intended for the treatment of compressed air or compressed gas. Its function is that of supplying filtered, lubricated air at the desired pressure for
More informationBase Models: 1-22SV Major Components GOULDS PUMPS. Commercial Water
Base Models: 1-22SV Base Models: 1-22SV F, P, R VERSIONS 1 Pump Body Stainless Steel AISI 304 EN 10088-1-X5-CrNi-10 (1.4301) 2 Impeller Stainless Steel AISI 304 EN 10088-1-X5-CrNi-10 (1.4301) 3 Diffuser
More informationCertification for Gas EN Certification EN EN Hygienic Certification
ISO 900-200 Certification Brandoni S.p.A. - Italy ISO 900-200 Certification Brandoni Qian An Valves Co. Ltd. Certification Brandoni S.p.A. Industrial valves has been one of the first companies in the Valsesia
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Introduction Modular design in two versions: Compact, sensor and electronics unit forming a single unit Separate, sensor and electronics separated, joined by a cable
More informationCBA AIR BREATHERS SERIES CBA HAND MOUNTING AIR FILTERS SERIES CBA HAND MOUNTING
IR FILTR IR FILTR RI HND MOUNTING ø H2 H3 IR RTHR RI HND MOUNTING ir breathers with threaded connection, zinc plated body and chrome plated cap. ir fi lter element (not replaceable): cellulose 3µm polyurathan
More informationRosemount 1153 Series D Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4388 Rev BA INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1974 and IEEE Std 344-1975 5.0 x 10 7 rads TID gamma radiation 7 g ZPA seismic 420 F (215.6 C) steam temperature
More informationDMH. Magnetic Inductive Flowmeter. for conductive fluids
Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C Connection:
More informationPage - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART 204 PERFORMANCE CHART VOX 205 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW
More informationPage - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART 204 PERFORMANCE CHART VOX 205 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW
More informationD-060 PN 16 D-060-C PN 16 D-062 PN 25 D-065 PN 40. A.R.I. FLOW CONTROL ACCESSORIES Ltd. Combination Air Valve for High Flow. Description.
D-00 PN Water Supply D-00- PN D-0 PN D-0 PN 0 ombination ir Valve for High Flow us-d00wtr- Description The D-00 series ombination ir Valve has the features of both an air release valve and an air & vacuum
More informationSeries SFA100/200/300
Cartridge Type/Disc Style Series SF00/200/300 Precision filtration for general gases used in the electronic industry, etc. Compressed air, Nitrogen, etc. PTFE membrane element is made into a cartridge.
More informationEE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features
EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone
More informationOur delivery program covers most of the critical steps in the field of the Chemical Industry.
CHEMICAL Our delivery program covers most of the critical steps in the field of the Chemical Industry. From small scale to industrial production, we can be your partner for building up your complete process.
More informationH-25 Series. Up to 20 gpm (75.7/min) H-25 Specialized Designs
H-25 Series Up to 2 gpm (75.7/min) H-25 Specialized Designs Hydra-Cell Slurry Duty pumps are specifically designed for abrasive slurry applications. See page 72 for complete specifications. The H-25 Hydra-Cell
More informationEE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features
EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone
More informationThermocouple temperature sensor omnigrad T -TSC 310
Technical information TI 255T/02/en 60019734 Thermocouple temperature sensor omnigrad T -TSC 310 Probe in direct contact with the process Insulation in mineral oxide Extension cable in glass fibre TSC
More informationSQUARE PORT KNIFE GATE VALVE
SQUARE PORT KNIFE GATE VALVE The SERIES 90 knife gate is a square port low-pressure valve for solid loaded fluids, mainly used in bulk handling and silo outlet applications in industries such as: Power
More informationAerospace and Defence
Aerospace and Defence Hydraulic, Fuel, Lubrication and Air Systems World Class Filtration Solutions Porvair Filtration Group Aerospace and Defence Hydraulic, Fuel, Lubrication and Air Systems Porvair Filtration
More informationDiaphragm seal with threaded connection Threaded design Model
Pressure Diaphragm seal with threaded connection Threaded design Model 990.10 WIKA data sheet DS 99.01 for further approvals see page 6 Applications For aggressive, hot, corrosive, environmentally hazardous
More informationNM, NMS. Close Coupled Centrifugal Pumps with flanged connections. Construction. Applications. Operating conditions. Motor
lose oupled entrifugal Pumps The electropumps NM, NM, NMS, NMS series comply with the uropean Regulation no. 7/. Materials omponents NM, NMS NM, NMS Pump casing ast iron ronze Lantern bracket NM asing
More informationSuitable for use in a variety of fluid systems.
Suitable for use in a variety of fluid systems. General Description Pipeline Wye Strainers are in thousands of applications in chemical, petroleum, pulp and paper, and utilities, as well as numerous commercial
More informationWorcester 5 Series. BS 5351 Approved Flanged Ball Valves
Worcester 5 Series S 5351 pproved Flanged all Valves Flowserve Worcester is proud to announce the introduction of its new 519/529 range of ball valves which replaces the DN 15 - sizes of the proven Series
More informationAll product images are indicative only General characteristics
submersible pumps PRODU AALOUE 04 Multi-channel open impeller All product images are indicative only eneral characteristics Multi-channel open impeller motor power poles discharge free max flow rate max
More informationF64G - Olympian Plus Plug-In System General purpose filter
> > Port size: /... 3/ (ISO G/PTF) > > Quick release bayonet bowl > > Effective liquid removal and positive solid filtration > > Large filter element area for minimum pressure drop Technical features Medium:
More informationBALL VALVES RS-WOG type
SC FEPA SA BARLAD BALL VALVES RS-WOG type APPLICATIONS Designed and prepared for use in the underground or above-ground pipeline systems which convey water, oil, natural gas, neutral or potentially corrosive
More informationTechnical Data Body Construction Materials Aluminum, brass, steel, 303 or 316 stainless steel O-ring Materials
200 Series 0 to 3000 psig heck Valves H200 Series 0 to 6000 psig heck Valves Features & enefits Quick opening/positive closing Provides a wide range of adaptability Large flow capacity The patented sealing
More information