1 DESIGN AND CONSTRUCTION STANDARDS Title: Section Direct-Digital Control System for HVAC & Mechanical Author: Author: Date Active Version Distribution: Date Approved By: Approved By: Robert E. McMains Date Robert E. McMains Date Discontinued: Cross-Reference (CR): Section , Section , Section , Section , Section , Section A. Purpose: This standard establishes a series of guidelines for specifying HVAC Controls for any construction project at the University. This Facilities Standard is not to be regarded as a specification. It is to provide minimal criteria for construction materials at UAB Facilities regarding code compliance, warranty, approved products, execution and uniformity for HVAC Controls. The University has a Strategic Partnering Agreement with Siemens Industry Inc., Building Technologies Division. This agreement establishes Siemens as a sole source provider for building automation systems to the University. All new construction for new buildings and in existing buildings should adhere to this agreement. Specifications developed for Direct Digital Controls should consider building dashboards and metering. B. Requirements: All new buildings shall have a computer workstation allowance in the project for accessing the building automation system. Due to the University security policies, the computer must be purchased by the University. It is desired that all of the building s equipment be integrated into the building automation system either existing, or as part of the ongoing project. In order to prevent component failures from affecting too much of a building s operation at the same time, the subsystem controls must be capable of operating in a stand-alone mode so as not to require remote access or communication with another controller or front-end computer to function. As a rule, the amount of equipment controlled in a single processor based controller should not exceed two energy using systems. The control strategies for HVAC equipment shall take advantage of current ASHRAE (American Society of Heating, Refrigeration and Air Conditioning Engineers) energy conservation measures that are required by code and, additionally, those measures that are cost effective and applicable to the current project. The Design Engineer shall provide UAB with an analysis to show requirements have been met for a minimum Energy Star rating of 75, and a simple payback period analysis for each energy conservation measure above and beyond that required by code. UAB will then decide if the additional measures will be included in the project. Energy conservation measures addressed by ASHRAE as pertain to air handlers include, but are not limited to ASHRAE 62.1, ASHRAE In addition to those conservation measures required by code, UAB requires the following: 1. Airside economizer on all recirculation air handlers 10,000 CFM or greater. (Reference Air Handling Systems Standard No ) 2. Heating water temperature setback on a linear scale based on actual outside air temperature.

2 3. All new construction and renovation projects shall use pressure independent (VAV or CAV) air terminals and central air handling units with variable speed drives to maintain space heating, cooling, and ventilation. Each terminal should be controlled by a space thermostat with a night setback override button. Setback programs and schedules shall already be pre-programmed and functional. Temperatures and schedules shall be readily accessible from the graphical user interface of the building automation system for the building. 4. Where independent air handlers, fan coil units, split-systems are used for spaces not served from a central air handling system, the thermostat that serves the space must have a night shutdown override button. These types of independent systems shall be programmed to be shutdown based on schedule. Shutdown programs and schedules shall be pre-programmed and functional. Temperatures and schedules shall be readily accessible from the graphical user interface of the building automation system for the building. 5. Controls for clinical and research laboratories shall have room pressurization and hood sash controls. Setback programs and schedules shall be already programmed and functional. Temperatures, air changes, pressures, and schedules shall be readily accessible from the graphical user interface of the building automation system for the building. Setbacks shall be implemented by an occupancy sensor(s) and the thermostat shall have a setback override button. Setbacks will utilize air change reductions based on air volume and not temperature. An indicator light shall be located near the thermostat showing that the room is either in setback mode or normal operating mode. 6. Spaces with significantly different occupancy should be on separate HVAC systems or separate zones, so that those areas can be shut down individually. 7. Heat recovery for air handling units with greater than a 50% outdoor air requirement (not including units with an airside economizer). 8. Demand controlled ventilation (CO 2 based) in all gymnasiums and all areas of assembly, classroom, lecture, auditoriums, foyers, and atriums greater than 2000 square feet. 9. Server rooms and electrical closets shall have their own VAV terminal, fan coil unit, or DX split system as not to affect the setback of the floor or area. C. Products: Equipment and software used shall be limited to the following Controls companies: 1. Siemens Controls utilizing the Apogee platform and PXC network controller and its P1 & Bacnet field buses. All software, hardware, third party software, equipment with computer chips shall: 1. Function without interruption or human intervention with four-digit year processing on all data. 2. Provide data interchange in the ISO 8601:2004 standard of CCYYMMDD or YYYYMMDD. 3. In the event that hardware, software or vendor generated programs do not meet the above conditions, the expense of new software, hardware and labor will be the expense of the Licensor/Vendor. Siemens shall furnish and install a fully integrated building automation system (BAS), incorporating direct digital controls (DDC) for energy management, equipment control and monitoring, and subsystems as defined in the project. Siemens shall be responsible for all BAS and Temperature Control wiring for a complete and operable system. All wiring shall be done in accordance with Section and all local and national codes. Building Automation Servers and Graphical User Interface (GUI) The servers for the building automation systems are provided by and maintained by UAB Facilities Management. They are located in the Facilities Management main server room. All user licenses, software revisions and updates are maintained by Facilities Management. 1. Due to security risk to the health care and research buildings that Facilities maintains no parties outside of UAB may have access to the building automation system unless it is approved by the Assistant VP, Facilities Management. 2. All GUI s on the servers shall have the same consistent layout with UAB Facilities header at the top of the page and the menu selectable footer at the bottom of the page. 3. Al GUI s shall have 3D symbols and objects including the floor plan GUI. 4. The background color for all GUIs shall be color code is RGB

3 5. All physical points, virtual set points, and command points must be presented on a graphical user interface on the building automation server. 6. All control system as-built drawings must be stored on the server and links to the drawings provided on the main GUI that represents the project. 7. Stand alone control systems where the building automation system is located on a separate server other than the servers provided by and maintained by Facilities Management are not allowed. If the UAB end user desires such a system then that system server will not be maintained by Facilities Management. D. Execution: TYPE 1 CONTROLS are associated with large energy using systems such as the following: 1. Chillers and other central plant equipment (200 Refrigeration Tons and up). 2. Boilers and associated heating plant equipment (50 Boiler horsepower and up). 3. Large air handling units, cooling and heating coils, fans, dampers, filters, and their associated equipment (10,000 Cubic feet per minute and up). 4. Large capacity steam converters and associated equipment (1,000 pounds per hour and up). 5. Large fans for ventilation systems (20,000 Cubic feet per minute and up). 6. Large pumps and associated equipment (1,000 gallons per minute and up). 7. Large preheat, reheat, and sub-cooling systems (10,000 Cubic feet per minute and up). 8. Large air distribution and exhaust systems (20,000 Cubic feet per minute and up). 9. All energy using equipment in critical areas such as operating rooms, burn treatment rooms, animal areas, special labs, etc. TYPE 2 CONTROLS are those mounted in or above the space and controlling terminal devices such as VAV (Variable Air Volume) boxes, terminal reheat boxes, lab pressurization & hoods, fan coil units, small air handling units or other such devices. Documentation: 1. In addition to the manufacturer s nameplate, a durable identification tag shall be permanently attached to the body of all instruments and devices. This tag will show the same identification that is shown on the control prints. Field mounted devices shall be provided with stainless steel tags, and panel mounted instruments with hard plastic nameplates. 2. Control system submittals that include the sequence of operation, proposed control devices and Control loop diagrams shall be submitted to the Design Engineer and the Facilities Energy Management ICE (Instrumentation Controls and Electronics) Division for review and approval. After approval, three copies shall be submitted to the University s Project Manager for distribution to Maintenance, Energy Management, and Facilities Planning, Design and Construction for comments. These drawings should be clear and legible, but not necessarily the final drawings. 3. All instrument drawings shall identify the instruments with the same tag number, as provided on the instrument itself. All tag numbers shall include the function identification, as well as, the instrument loop number common to all devices on that loop. In addition to printed copies, instrument drawings and information other than manuals will be provided to the University in electronic format compatible with AUTOCAD, Adobe Acrobat, or Microsoft Word. 4. A typical loop diagram as defined by the American Standards Institute/Instrument Society of America Standard 5.2, 5.3, and 5.4 Instrumentation Symbols and Identification shall be provided for each loop of each instrument, identifying the connections for each instrument. 5. Control drawings shall be provided for every control system during the design stages and shall be submitted with the design stages. These drawings shall show all major equipment and the control components associated with this equipment, including connections between sensors, controllers, all interlocks from external systems, and actuators. The drawings shall also define the sequence of operation of the system. 6. An electronic copy of the as-built control drawings and any later revisions shall be stored on the building automation server and a link to the drawing shall be provided on the main GUI for the project. Three sets of bound hard copies of the as-built control drawings, including the as-built sequence of operation, must be delivered to the University s Project Manager fourteen calendar days before orientation for distribution to the Facilities Energy Management ICE Division, Maintenance, Energy Management, and Facilities Planning, Design and Construction. If changes are made during the warranty period, three additional sets showing those changes are to be submitted at the completion of the warranty period. All drawings must show each control loop, completed with all external

4 components that affect operation of the loop. All field wiring must be shown as individually field marked at all terminals and junctions for field identification. No field wiring should be shown as typical. 7. Operating, maintenance and repair manuals must be delivered to the University s Project Manager fourteen calendar days before orientation for distribution to the Facilities Energy Management ICE Division, Maintenance, Energy Management and Facilities Planning, Design and Construction. These manuals must be complete with information to operate, maintain and repair the equipment. The University understands that control manufacturers may have some proprietary information relating to MICRO chips, program execution, board level components and built-in program subroutines; however, it is unacceptable to the University for a manufacturer to limit information for operating, repairing and programming control systems to its employees or representatives exclusively. 8. Fourteen days before orientation the Contractor shall provide and mount, in the equipment location, design operating sequences as well as points for all energy consuming equipment installed. The Contractor will provide framing to encase and protect such information. At the end of the warranty period this information will be upgraded if changes have been made. The University s Energy Management and Maintenance Departments should receive this information in an electronic format using Microsoft Word, AUTOCAD, or PDF. 9. Software and hardware required to operate, maintain and repair all parts and equipment related to the control system shall be turned over to Energy Management ICE Division through the University s Project Manager at the time the University takes over operation of the area. This information will include copies of the program, configuration files in a format for downloading directly into the systems, a format that allows editing and reinstalling. Communication devices, cables, coded keys, and any other hardware required to work with the system will be provided to the University s Project Manager at this time. 10. The University will comply with software license for systems. Due to the number of systems installed at the University, and the rapid changes expected in software, the University desires all software to be University licensed (all of the University), with basic verbal assistance when requested, so that software may be installed in remote locations within the University. It is also required that all software be backward compatible to existing systems. Communication Between Controls: TYPE 1 CONTROLS must be installed with the capability of communicating over the University s fiber optic Ethernet LAN (Local Area Network) network, using TCP/IP protocol only, to the University s servers without going through an operator s station. The network interface card will be 100 Meg Ethernet compatible 10/100 switchable. Although some buildings are not integrated into the existing fiber network at this time, all buildings will be in the future. Whether or not fiber is available, the controls will be Ethernet compatible for access when fiber connection is available. Type 1 Controls shall be provided with translators, software and other equipment, as required, to allow these controls to be monitored, reset, histories read, and all other functions performed from the local network controller. TYPE 2 CONTROLS shall also communicate as described above, but may use Type 1 Controller as a gateway. This communications protocol shall be the network controller s proprietary RS485 bus or Bacnet MSTP bus. THIRD PARTY EQUIPMENT CONTROLS that have controllers as an integral part of the equipment package, such as chillers, boilers, electrical switchgear, etc., shall only use the proprietary or Bacnet bus of the building automation system that is monitoring and/or controlling it. If this is not an available option on the equipment and all efforts have been exhausted to provide the equipment with one of these two option then Modus or LON can be used. These third party communication installations must be approved by the Facilities Energy Management ICE Division during the design review. Third party equipment that use the BACnet protocol must have a University assigned BACnet instance number so that the new equipment s controller does not have a communications conflict with existing building automation BACnet controllers. The instance number must be given to the manufacture when ordering the equipment. When the instance number is requested by the party purchasing the equipment the Energy Management ICE Division will assign it. Related Equipment: There is certain related equipment, not strictly classified as controls, which has a control function; therefore, that equipment is to be considered as such and is addressed in this section for emphasis. Lighting controls shall be a Siemens solution that works and communicates using their controllers. Variable Frequency Drives (VFD s) are so interrelated to the control system as to be considered a part of that system. Drive specifications are addressed in Facilities Standard Signals between the control system and the drive

5 shall be optically isolated to prevent a conflict between grounding potential. The drive shall be given full consideration as to its function in the design of the controls as they relate to airflow, coil conditions, chilled and hot water reset, etc. Wiring 1. All control wiring must be shielded and twisted as pairs equal to the following Beldon numbers: Single twisted shielded pair 8770; three conductor twisted shielded for RTD s (Resistant Temperature Devices) 8770; two conductor twisted shielded plenum rated 88760; three conductor twisted shielded plenum rated All control wiring should be installed in steel conduit as specified in Electrical Standard Conduit will be marked purple tape as defined in Electrical Standard A minimum distance of twelve inches shall be maintained between conduit containing power wiring and control wiring. Where power and control wire cross, it shall cross at right angles. 3. All building automation controllers and panels shall be on emergency power. The only exception is for buildings that don t have emergency power. All building level controllers must have an uninterruptible power supply (UPS) with a fail over 4 pole relay that switches it back to the panel electrical circuit upon failure. The 4 th pole on the relayed shall be wired back to the building automation as a failed UPS alarm. The system s electrical power and ground circuit will be tested for ground loops, voltage spikes, harmonics, etc., and shall be verified suitable for operation with the control system. A copy of this test will be included in the calibration documents. When necessary, power conditioners will be installed. 4. All cables between instruments, panels, and other control components shall be identified by permanently identified cable markers on each end of the cable at each termination point. This identification shall be unique for each cable or wire so that each will be identified on the control print. All terminals shall be numbered in the same unique manner and should have a separator between the screw heads. All cables and loose wires in panels shall be run in plastic enclosures designed for that purpose. All panels should be wired so that low voltage 24 volts alternating or direct current is kept separate from high voltage 120 volts alternating current. 5. All control panel wiring will enter through the bottom of the cabinet no penetrations into the top of the cabinet are acceptable. 6. Color coding identification will comply with Standard Certified Factory Training and Orientation Training and orientation needs will vary greatly for different projects. Training for the University s Maintenance and Energy Management personnel is a necessity and is required. The specific requirements should be discussed with the Facilities Energy Management ICE Division Committee. Forty hours of on-site training by a factory certified technician should be provided. This will be performed during normal working hours and will be in addition to orientation. The University will work with the Contractor to schedule these hours to be acceptable to both the University and the Contractor, but no more than fourteen (14) calendar days notice should be required. This training will be videotaped by the Contractor. Professionally produced training tapes may be substituted for the Contractor taping the training. End of Standard

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. Provide a building temperature control/building automation system (BAS) for the space temperature control and monitoring of defined environmental conditions. General system

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning Building Automation PART 1 - GENERAL 1.01 OVERVIEW A. Provide a building temperature control/building automation system (BAS) for the space temperature control and monitoring of defined environmental conditions.

More information

A. The purpose of this section is to specify Division 23 responsibilities in the commissioning process.

A. The purpose of this section is to specify Division 23 responsibilities in the commissioning process. SECTION 23 99 50 - (ADD#4) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

City of San Mateo Clean Water Program Programmable Logic Controller (PLC) and Human Machine Interface (HMI) Programming Services

City of San Mateo Clean Water Program Programmable Logic Controller (PLC) and Human Machine Interface (HMI) Programming Services ATTACHMENT A SAMPLE SCOPE OF SERVICES PLC & HMI PROGRAMMING City of San Mateo Clean Water Program Programmable Logic Controller (PLC) and Human Machine Interface (HMI) Programming Services December, 2017

More information

GEN X. Mobile APP based VVT System Using Programmable Wired Thermostats. Automatic Temperature Control Specification

GEN X. Mobile APP based VVT System Using Programmable Wired Thermostats. Automatic Temperature Control Specification GEN X Mobile APP based VVT System Using Programmable Wired Thermostats Automatic Temperature Control Specification Section 15950 - Controls and Automation PART 1: General 1.1 The automatic temperature

More information

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard PART 1 GENERAL 1.1 Scope A. The intent of this specification is to provide power control for the parallel operation of generator

More information

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT SECTION 23 05 12 GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete

More information

2B. Performance Advantages of Alerton BACnet. 1. Alerton Overview

2B. Performance Advantages of Alerton BACnet. 1. Alerton Overview 1. Alerton Overview Alerton recognized the benefits of BACnet and introduced the industry's first native BACnet system, BACtalk. This forward thinking is consistent with Alerton's rich history of technology

More information

CONSTRUCTION REQUIREMENTS

CONSTRUCTION REQUIREMENTS CONSTRUCTION REQUIREMENTS Note: The buildings on the UCCS campus are divided into two categories: General Fund and Auxiliaries. General Fund Buildings include academic and administrative functions. Auxiliary

More information

SECTION FIELD PANELS

SECTION FIELD PANELS Stanford University Facilities Design Guidelines SECTION 25 14 23 FIELD PANELS PART 1 - GENERAL 1.1 SUMMARY A. This section includes control panel and enclosure requirements for building control systems.

More information

Retrocommissioning Investigation Report

Retrocommissioning Investigation Report Continuous Optimization for Commercial Buildings Program Retrocommissioning Investigation Report March 22, 2013 Prepared for: Thompson Rivers University International Building BC Hydro #:COP10-353 Prism

More information

GATES-HILLMAN CENTERS

GATES-HILLMAN CENTERS GATES-HILLMAN CENTERS CARNEGIE MELLON UNIVERSITY CASE STUDY ENERGY EFFICIENCY CARNEGIE MELLON UNIVERSITY Carnegie Mellon University looked to SEMCO to provide solutions for their energy efficiency goals.

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 16060 Grounding and Bonding This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or

More information

FACILITIES MANAGEMENT

FACILITIES MANAGEMENT FACILITIES MANAGEMENT Planning, Design & Construction November 26, 2014 Re: Request for Qualifications - Commissioning Services Bowen Science Building Modernize Building Systems University of Iowa The

More information

LUNA SECONDARY PREPARATORY SCHOOL DALLAS, TEXAS ADDENDUM NO. 1

LUNA SECONDARY PREPARATORY SCHOOL DALLAS, TEXAS ADDENDUM NO. 1 LUNA SECONDARY PREPARATORY SCHOOL DALLAS, TEXAS ADDENDUM NO. 1 PROJECT: Luna Secondary Preparatory School HKS Project No. 16389.000 DATE: 17 December 2013 TO: All Offerors The Proposal Documents shall

More information

Acutherm was spec d here. Building Automation Guide for Therma-Fuser Systems

Acutherm was spec d here. Building Automation Guide for Therma-Fuser Systems Building Automation Guide for Therma-Fuser Systems Acutherm was spec d here BUILDING AUTOMATION OPTIONS FOR THERMA-FUSER SYSTEMS As energy costs continue to rise, the management of energy while balancing

More information

Unit Substation Transformer Construction Checklist (under 500 kva)

Unit Substation Transformer Construction Checklist (under 500 kva) Unit Substation Transformer Checklist (under 500 kva) Building: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing.

More information

The baseline building system for compliance with Senate Bill 668 is defined by Appendix G,

The baseline building system for compliance with Senate Bill 668 is defined by Appendix G, Project: North Carolina A&T State University New Student Health Center SCO #: 08-08109-01A 1.0 Heating, Ventilating and Air Conditioning (HVAC) Baseline Building Systems Senate Bill 668 Compliance The

More information

BID # Bookstore & Gateway HVAC Controls Upgrade SECTION "C" TECHNICAL SPECIFICATIONS OWNER

BID # Bookstore & Gateway HVAC Controls Upgrade SECTION C TECHNICAL SPECIFICATIONS OWNER BID # 18 20 Bookstore & Gateway HVAC Controls Upgrade SECTION "C" TECHNICAL SPECIFICATIONS OWNER Board of Trustees Middlesex County College 2600 Woodbridge Avenue P.O. Box 3050 Edison, New Jersey 08818

More information

A. All drawings and general provisions of the contract, including all other Division 01 and general and supplementary conditions.

A. All drawings and general provisions of the contract, including all other Division 01 and general and supplementary conditions. SECTION 23 0800 COMMISSIONING HVAC PART 1 - GENERAL 1.1 OWNER FURNISHED 1.2 RELATED DOCUMENTS A. All drawings and general provisions of the contract, including all other Division 01 and general and supplementary

More information

Building Automation Systems

Building Automation Systems Published on Business Energy Advisor (https://alliantenergy.bizenergyadvisor.com) Home > Building Automation Systems Building Automation Systems The building automation system (BAS) has become the accepted

More information

KCTCS Using Agency Project Requirements for Building Automation Systems

KCTCS Using Agency Project Requirements for Building Automation Systems KCTCS Using Agency Project Requirements for Building Automation Systems Table of Contents 1. Introduction 2. Definition of Terms (See Section A) 3. KCTCS BAS Standards and Compliance Team Coordination

More information

DATE: July 27, 2018 TO: All Bidders FROM: Jo Nell Miller, Purchasing Specialist SUBJECT: Addendum 2 Bid 550 Moorpark College Gymnasium Renovation

DATE: July 27, 2018 TO: All Bidders FROM: Jo Nell Miller, Purchasing Specialist SUBJECT: Addendum 2 Bid 550 Moorpark College Gymnasium Renovation DATE: July 27, 2018 TO: All Bidders FROM: Jo Nell Miller, Purchasing Specialist SUBJECT: Addendum 2 Bid 550 Moorpark College Gymnasium Renovation This addendum is hereby made part of the Contract Documents

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

Building Controls Strategies Conference. Retro-Commissioning with BAS Overview. 10 March Steve Brown, CAP ESD Controls Team Leader

Building Controls Strategies Conference. Retro-Commissioning with BAS Overview. 10 March Steve Brown, CAP ESD Controls Team Leader Building Controls Strategies Conference Retro-Commissioning with BAS Overview 10 March 2015 Steve Brown, CAP ESD Controls Team Leader Kevin Caho PE, LEED AP ESD Energy Engineer Agenda BAS Overview RCx

More information

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 02/06/2013 BUILDING SURVEY DATE

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 02/06/2013 BUILDING SURVEY DATE 0067 1110 WEST GREEN STREET URBANA, ILLINOIS 61801 SYSTEM CONDITION INDEX.810 PRIMARY BUILDING USE BUILDING SURVEY TEAM BUILDING SYSTEM REPLACEMENT COST $ 18,640,900 OFFICE BUILDING GROSS SQUARE FEET 175,513

More information

SECTION HVAC INSTRUMENTATION AND CONTROLS INSTALLATION. (Applicable to IUPUI Only)

SECTION HVAC INSTRUMENTATION AND CONTROLS INSTALLATION. (Applicable to IUPUI Only) SECTION 15957 (Applicable to IUPUI Only) I. GENERAL A. NOTES 1. The University has a pre-purchase agreement (PPA) with Johnson Controls (JCI) and Siemens Building Technologies (SBT). The University will

More information

Existing Mechanical Conditions

Existing Mechanical Conditions Figure 2 Existing Mechanical Conditions Design Parameters During the entire project, various general and discipline specific parameters affected the design approach. These design parameters include governmental,

More information

EXHIBIT A SCOPE OF SERVICES MAINTENANCE OF TRANE HVAC SYSTEMS

EXHIBIT A SCOPE OF SERVICES MAINTENANCE OF TRANE HVAC SYSTEMS EXHIBIT A SCOPE OF SERVICES MAINTENANCE OF TRANE HVAC SYSTEMS DISTRICT VII, HEADQUARTERS FACILITY AND TAMPA BAY SUNGUIDE REGIONAL TRAFFIC MANAGEMENT CENTER I. PURPOSE: DISTRICT VII, HEADQUARTERS FACILITY

More information

Field Commander. Overview. Operations. Custom Solution. Building Startup/Shutdown

Field Commander. Overview. Operations. Custom Solution. Building Startup/Shutdown Commercial Custom Office Solution Building: Overview To meet the energy demands of a commercial office building, a full-featured energy management solution is needed. A custom energy management system

More information

ASHRAE TECHNICAL SEMINARS. Lakewood, CO April 16, 2010

ASHRAE TECHNICAL SEMINARS. Lakewood, CO April 16, 2010 ASHRAE TECHNICAL SEMINARS Lakewood, CO April 16, 2010 Greg Bradshaw Bradshaw Building Solutions, Inc. 303-277-0420 (cell 303-475-7714) 7714) greg@bradshawbuildingsolutions.com The Building Automation System

More information

Special Specification 6292 Radar Vehicle Detection System for Signalized Intersection Control

Special Specification 6292 Radar Vehicle Detection System for Signalized Intersection Control Special Specification 6292 Radar Vehicle Detection System for Signalized Intersection Control 1. DESCRIPTION 2. MATERIALS Furnish, install, relocate, or remove radar vehicle detection systems (RVDS) of

More information

Request for Bids. At The Greenville-Spartanburg International Airport

Request for Bids. At The Greenville-Spartanburg International Airport Request for Bids At The Greenville-Spartanburg International Airport Addendum No. 2 June 27, 2011 All Bidders shall include with their bid submittal a signed statement indicating they have reviewed and

More information

Attachment 1: RAE Corporation Technical Specification

Attachment 1: RAE Corporation Technical Specification Attachment 1: RAE Corporation Technical Specification RAE Corporation Phone: 918-825-7222, ext. 105 Steve Corbin Quote# XXXX Qty Customer Tag Technical Systems Model Number 1 ACC-4 10A0-162-S General Scope

More information

Equipment Specifications Low Voltage. Active Harmonic Filter

Equipment Specifications Low Voltage. Active Harmonic Filter Equipment Specifications Low Voltage Active Harmonic Filter 1.0 General Description This section contains the design standards, general equipment type and configuration, components, product description,

More information

Capital Projects Group Air Terminal Units Specification

Capital Projects Group Air Terminal Units Specification Capital Projects Group Air Terminal Units Specification Specification 23 36 00 Revision 0 Date: August 2018 Air Terminal Units Specification Specification 23 36 00 Publication Date: August 2018 COPYRIGHT

More information

CONTINUOUS COMMISSIONING OF SALT LAKE COMMUNITY COLLEGE SOUTH CITY CAMPUS

CONTINUOUS COMMISSIONING OF SALT LAKE COMMUNITY COLLEGE SOUTH CITY CAMPUS CONTINUOUS COMMISSIONING OF SALT LAKE COMMUNITY COLLEGE SOUTH CITY CAMPUS Song Deng, P.E. and Dan Turner, P.E., Ph.D., Energy Systems Laboratory, Texas A&M University System, College Station, Texas Jim

More information

Project Information. Measure Description

Project Information. Measure Description Project Information Project ID#: CE07M016 Measure: Multiple Electric : 452,593 kwh, 8.84 kw, 39.26 kw Facility Type School Technology: Multiple Measure Description CH-1 - Chiller Plant Optimization and

More information

LABORATORY CONTROL SOLUTIONS FROM TSI

LABORATORY CONTROL SOLUTIONS FROM TSI LABORATORY CONTROL SOLUTIONS FROM TSI UNDERSTANDING, ACCELERATED SAFE, FLEXIBLE CONTROL SOLUTIONS SAFETY Research in laboratories helps advance science in many different disciplines. Professionals working

More information

Element Z General Design Requirements Existing Facilities Information

Element Z General Design Requirements Existing Facilities Information Anderson Central 100B, PART 1 - INTRODUCTION 1.01 OVERVIEW A. This Section provides general information for building systems and components. B. Refer to the Owner s Design Guideline Elements A though G

More information

Study on Energy Saving Control of Electrical System in Office Building

Study on Energy Saving Control of Electrical System in Office Building 847 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 59, 2017 Guest Editors: Zhuo Yang, Junjie Ba, Jing Pan Copyright 2017, AIDIC Servizi S.r.l. ISBN 978-88-95608-49-5; ISSN 2283-9216 The Italian

More information

Karl Helmink, P.E., CEM Retrocommissioning Manager University of Illinois. Retrocommissioning Saving the Planet One Building at a Time

Karl Helmink, P.E., CEM Retrocommissioning Manager University of Illinois. Retrocommissioning Saving the Planet One Building at a Time Karl Helmink, P.E., CEM Retrocommissioning Manager University of Illinois Retrocommissioning Saving the Planet One Building at a Time AIA Quality Assurance Portland Energy Conservation, Inc is a registered

More information

TDPs provide you with new technical training materials designed to help your contractors, engineers, and designers to effectively design, specify,

TDPs provide you with new technical training materials designed to help your contractors, engineers, and designers to effectively design, specify, TDP Catalog TDPs provide you with new technical training materials designed to help your contractors, engineers, and designers to effectively design, specify, sell, and apply HVAC equipment in commercial

More information

SECTION MOTOR CONTROL CENTER

SECTION MOTOR CONTROL CENTER SECTION 16445 MOTOR CONTROL CENTER PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Motor Control Center (MCC). The contract item includes demolition and removal of existing MCC;

More information

201 Charlotte Street, Brisbane, Queensland

201 Charlotte Street, Brisbane, Queensland 201 Charlotte Street, Brisbane, Queensland Building Profile Building Construction date 1983 Refurbishment date 2001 Owner Building Size Refurbishment Team Building Management Awards Ratings Overview 201

More information

Baffled Openings at Chain Link Fencing: Design shall consist of two end-posts set 4 feet apart, and a 10 foot wide chain-link fence panel equal in height as the adjacent fence. Chain link fence panel shall

More information

The Building Systems Detective

The Building Systems Detective Building Re-Commissioning Presented By Greg Bradshaw, CEM The Building Systems Detective Bradshaw Building Solutions, Inc. 303-475-77147714 greg@bradshawbuildingsolutions.com Introduction Re-Commissioning

More information

Leading Techniques for Energy Savings in Colleges and Universities

Leading Techniques for Energy Savings in Colleges and Universities Universities Leading Techniques for Energy Savings in Colleges and Universities Learn how building automation products and services can reduce energy costs at colleges and universities. This paper outlines

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Digital Loop Carrier System 1993 Specifications CSJ 0039-17-129 SPECIAL SPECIFICATION ITEM 6797 Digital Loop Carrier System 1.0 Description. This Item shall govern for the furnishing and installation of the Digital Loop Carrier System

More information

1993 Specifications CSJ SPECIAL SPECIFICATION 4880 Bridge Equipment Cabinets

1993 Specifications CSJ SPECIAL SPECIFICATION 4880 Bridge Equipment Cabinets 1993 Specifications CSJ 0331-04-050 SPECIAL SPECIFICATION 4880 Bridge Equipment Cabinets 1. Description. This Item shall govern for furnishing and installation of Equipment Cabinets for the Bridge Collapse

More information

Can I customize a building automation system to meet my building needs and my budget?

Can I customize a building automation system to meet my building needs and my budget? Can I customize a building automation system to meet my building needs and my budget? The Web-based TALON system gives you the cost-effective control you need. Answers for industry. 2 Scalability made

More information

High Technology Energy Savings Guide

High Technology Energy Savings Guide High Technology Energy Savings Guide The high-tech industry is a crucial and dynamic part of Oregon s economy that is expected to grow faster than other industries over the next decade. Working in a highly

More information

Fixed equipment shall generally be furnished and installed by the General Contractor as part of the construction contract.

Fixed equipment shall generally be furnished and installed by the General Contractor as part of the construction contract. SECTION 11 00 00 - EQUIPMENT GENERAL INFORMATION Fixed equipment shall generally be furnished and installed by the General Contractor as part of the construction contract. Movable equipment shall, as a

More information

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM Digital Loop Carrier System 1993 Specifications CSJ 0072-12-153, etc. SPECIAL SPECIFICATION ITEM 6285 Digital Loop Carrier System 1.0 Description. This Item shall govern for the furnishing and installation of the Digital Loop Carrier

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 25 0800 - COMMISSIONING OF INTEGRATED AUTOMATION GENERAL 1.1 SUMMARY This section defines responsibilities of the Integrated Automation Contractor to facilitate the Commissioning process for the

More information

Capital Projects Group Gas Fired Warm Air Furnace Specification

Capital Projects Group Gas Fired Warm Air Furnace Specification Capital Projects Group Gas Fired Warm Air Furnace Specification Specification 23 54 16 Revision 1 Date: September 2018 Gas Fired Warm Air Furnace Specification Specification 23 54 16 Publication Date:

More information

Bid Package 15A Mechanical

Bid Package 15A Mechanical Bid Package 23A Mechanical & HVAC The successful Subcontractor acknowledges and agrees to the requirements set forth by this bid package and its descriptions and in conjunction with all other Construction

More information

Absolute Energy Raters Commissioning Plan Outline Template

Absolute Energy Raters Commissioning Plan Outline Template IMPORTANT NOTICE: This sample document is provided for instructional purposes only. Absolute Energy Raters is not rendering advice concerning any commission project or practices. This document is neither

More information

DIRECTIVE 15H-9 Issue date: October 2018 COMMISSIONING

DIRECTIVE 15H-9 Issue date: October 2018 COMMISSIONING DIRECTIVE 15H-9 Issue date: October 2018 COMMISSIONING Purpose: The purpose of this Directive is to describe, in outline, the requirements of Commissioning on SUCF Projects. 1. Applicability a. New York

More information

Energy metering is required to comply with the requirements of the Building Regulations.

Energy metering is required to comply with the requirements of the Building Regulations. Sub-Metering Aesthetic Energy metering is required to comply with the requirements of the Building Regulations. All energy usage for water, heat, chilled water, steam, compressed air, electricity and gas

More information

SECTION SECONDARY UNIT SUBSTATIONS

SECTION SECONDARY UNIT SUBSTATIONS SECTION 26 12 16 SECONDARY UNIT SUBSTATIONS PART 1 GENERAL 1.1 SUMMARY This section describes metal-clad, indoor or outdoor, secondary unit substations with integral primary fused disconnect switches,

More information

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less) SECTION 260523 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less) PART 1 - GENERAL 1.1 SUMMARY A. Related Documents: 1. Drawings and general provisions of the Subcontract apply

More information

Sequences, Integration: Who's in Control? Wick Fisher White Consulting Engineers Hanson Professional Services Inc.

Sequences, Integration: Who's in Control? Wick Fisher White Consulting Engineers Hanson Professional Services Inc. Sequences, Integration: Who's in Control? Tony DiLeonardo, LEED AP, CxA Robert J. Knoedler, P.E., CxA, EMP Wick Fisher White Consulting Engineers Hanson Professional Services Inc. AIA Quality Assurance

More information

Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs. Valent is a business of Unison Comfort Technologies.

Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs. Valent is a business of Unison Comfort Technologies. Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs Valent is a business of Unison Comfort Technologies. When your HVAC system design calls for high-percentage or 100%

More information

Beyond Advanced Lighting Controls: Reaching Net Zero with Integrated Building Controls

Beyond Advanced Lighting Controls: Reaching Net Zero with Integrated Building Controls Beyond Advanced Lighting Controls: Reaching Net Zero with Integrated Building Controls James Donson, Jon Schoenfeld and Bruce Chamberlain, kw Engineering ABSTRACT Many manufacturers offer proven ALC systems

More information

Retail Effects of ANSI/ASHRAE/IES Standard

Retail Effects of ANSI/ASHRAE/IES Standard Retail Effects of ANSI/ASHRAE/IES Standard 90.1-2016 Prepared by Dialectic Inc. INTRODUCTION Background ANSI/ASHRAE/IES 90.1-2016 Energy Standard for Buildings Except Low-Rise Residential Buildings replaces

More information

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

PIP PCEPA003 Process Analyzer System Field Installation Guidelines January 2016 Process Control PIP PCEPA003 Process Analyzer System Field Installation Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities,

More information

SMART HVAC & LIGHTING SYSTEMS. Savings From Two Major C&I End Uses

SMART HVAC & LIGHTING SYSTEMS. Savings From Two Major C&I End Uses SMART HVAC & LIGHTING SYSTEMS Savings From Two Major C&I End Uses September 21, 2016 PRESENTATION OVERVIEW Why this focus? Significant savings potential Smart controls coupled with more efficient technologies

More information

What s My Baseline? ASHRAE

What s My Baseline? ASHRAE 2010 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions (2010, vol 116,part 2). For personal use only. Additional reproduction,

More information

Space Conditioning Systems, Ducts, and Fans (Page 1 of 6)

Space Conditioning Systems, Ducts, and Fans (Page 1 of 6) Space Conditioning Systems, Ducts, and Fans (Page 1 of 6) Project : Enforcement Agency: Permit Number: A. General Information 01 Dwelling Unit 02 Climate Zone: 03 Dwelling Unit Total Conditioned Floor

More information

Level 1 Modules tdp-101 hvac industry overview tdp-103 concepts of air conditioning tdp-102 abcs of comfort

Level 1 Modules tdp-101 hvac industry overview tdp-103 concepts of air conditioning tdp-102 abcs of comfort TDP-101 HVAC Industry Overview This TDP provides a general overview of the commercial HVAC industry and provides an awareness of the design process and construction. The documents involved in construction,

More information

C o u n t y o f F a i r f a x, V i r g i n i a

C o u n t y o f F a i r f a x, V i r g i n i a 001961 Page 2 C o u n t y o f F a i r f a x, V i r g i n i a A D D E N D U M DATE: August 2, 2016 ADDENDUM NO. 4 TO: REFERENCE: FOR: DUE DATE/TIME: ALL PROSPECTIVE BIDDERS Government Center Generator System

More information

Georgetown University New Science Center

Georgetown University New Science Center Georgetown University New Science Center Final Thesis Proposal PENN STATE UNIVERSITY Prepared For: Dr. William P. Bahnfleth Department of Architectural Engineering Prepared By: Kevin M Edstrom Mechanical

More information

Army Exceeds Energy Goal Ahead of Mandate (Actual Energy Reduction of 38% vs 30% and Achieved in 2010 vs 2015)

Army Exceeds Energy Goal Ahead of Mandate (Actual Energy Reduction of 38% vs 30% and Achieved in 2010 vs 2015) Army Exceeds Energy Goal Ahead of Mandate (Actual Energy Reduction of 38% vs 30% and Achieved in 2010 vs 2015) NDIA E 2 S 2 May 9-12, 2011 New Orleans, LA Overview Background Energy Conservation Measures

More information

Changes to the Minnesota Commercial Energy Code. Presented by: Andy Thielen, PE

Changes to the Minnesota Commercial Energy Code. Presented by: Andy Thielen, PE Changes to the Minnesota Commercial Energy Code Presented by: Andy Thielen, PE Warning! The following is an outline of proposed code changes. There is no guarantee that the final code adopted by the State

More information

Price Flat Faced Displacement Diffusers

Price Flat Faced Displacement Diffusers Price Flat Faced Displacement Diffusers Division 23 Heating, Ventilating, and Air Conditioning Section 23 37 13 Diffusers, Registers, and Grilles PART 1 GENERAL 1.01 Section includes: A. Flat Faced Displacement

More information

Attachment A Scope of Work (SOW) Oxnard School District OSD 2018 HVAC Project for Five (5) Schools Phase 2

Attachment A Scope of Work (SOW) Oxnard School District OSD 2018 HVAC Project for Five (5) Schools Phase 2 Attachment A Scope of Work (SOW) Oxnard School District OSD 2018 HVAC Project for Five (5) Schools Phase 2 SCOPE OF WORK The Design-Build Contractor shall provide all of the necessary engineering, material

More information

SECTION COOLING TOWER

SECTION COOLING TOWER PART 1 GENERAL 1.1 SECTION INCLUDES A. Mechanical induced draft Cooling Tower B. Controls C. Ladder and handrails 1.2 REFERENCES SECTION 23 65 00 COOLING TOWER A. ANSI/AFBMA 9 - Load Rating and Fatigue

More information

Commercial Building Performance Evaluation System for HVAC Diagnostics and Commissioning

Commercial Building Performance Evaluation System for HVAC Diagnostics and Commissioning Commercial Building Performance Evaluation System for HVAC Diagnostics and Commissioning Stuart S. Waterbury and Donald J. Frey, Architectural Energy Corporation Karl F. Johnson, Electric Power Research

More information

Promulgation Details for 1 RCNY

Promulgation Details for 1 RCNY Promulgation Details for 1 RCNY 103-07 This rule became effective on October 13, 2012. Since such date, one or more amendments have been made to this rule. Each rule amendment has its own effective date

More information

Low Voltage Switchgear Construction Checklist (under 500 kva)

Low Voltage Switchgear Construction Checklist (under 500 kva) Low Voltage Switchgear Checklist (under 500 kva) Project: Building: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing.

More information

SECTION AIR-TO-AIR ENERGY RECOVERY EQUIPMENT

SECTION AIR-TO-AIR ENERGY RECOVERY EQUIPMENT SECTION 23 72 00 AIR-TO-AIR ENERGY RECOVERY EQUIPMENT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Section 17 Metering and Controls.

Section 17 Metering and Controls. Design Guidelines Section 17 Metering and Controls. www.canterbury.ac.nz/learningresources Standards in the Design Guidelines Suite Design Standard Guidelines Index: 01 General 02 Architecture 03 Audio

More information

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma LEED Green Building Certification The purpose of the LEED Green Building Rating is to provide a national standard that aims to improve environmental, health and economic performance of buildings using

More information

BCM00 Introduction to Building Controls and HVAC (available on request) One day course BCIA Members VAT Non-members VAT

BCM00 Introduction to Building Controls and HVAC (available on request) One day course BCIA Members VAT Non-members VAT BCM00 Introduction to Building Controls and HVAC (available on request) One day course BCIA Members 220 + VAT Non-members 300 + VAT This introductory course is designed for those who do not require the

More information

A. The work consists of furnishing a Chiller Noise Reduction System as listed in the specifications.

A. The work consists of furnishing a Chiller Noise Reduction System as listed in the specifications. SECTION 32 31 14 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply

More information

SECTION HEAT TRACING FOR PLUMBING PIPING

SECTION HEAT TRACING FOR PLUMBING PIPING SECTION 22 05 33 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable in the section

More information

PROJECT NAME CLEVELAND CLINIC PROJECT #

PROJECT NAME CLEVELAND CLINIC PROJECT # CLEVELAND CLINIC PROJECT # [This is a sample of a general project M&V specification these specifications should be incorporated into the HVAC Control specifications and modified to the specific job requirements]

More information

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES...

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES... DIVISION 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN Contents 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION 13 00 60 LIST OF FIGURES... 6 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN 1. General Requirements

More information

16300 HIGH VOLTAGE DISTRIBUTION

16300 HIGH VOLTAGE DISTRIBUTION 16300 HIGH VOLTAGE DISTRIBUTION PART 1: GENERAL 1.01 WORK INCLUDED A. Most new loads will be served from the underground electric distribution system. This system is a primary open loop configuration served

More information

ARMSTRONG DESIGN ENVELOPE FAQ

ARMSTRONG DESIGN ENVELOPE FAQ ARMSTRONG DESIGN ENVELOPE FAQ File No: 100.202 Date: december 28, 2015 Supersedes: 100.202 Date: september 22, 2015 q1 a1 Armstrong is the greenest, most cost effective and most flexible building mechanical

More information

SECTION COMMISSIONING

SECTION COMMISSIONING SECTION 018100 ART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Building commissioning of the following systems: a. Building Envelope. b. HVAC system: interaction of cooling, heating, and comfort delivery

More information

SECTION COMMISSIONING

SECTION COMMISSIONING SECTION 018100 ART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Building commissioning of the following systems: a. Building Envelope. b. HVAC system: interaction of cooling, heating, and comfort delivery

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11241 - Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S PART 1 - GENERAL... 1 1.01 Scope... 1 1.02 Scope of Work... 1 1.03

More information

B. OPR, BoD, and BoD-HVAC documentation prepared by Owner and Architect contains requirements that apply to this Section.

B. OPR, BoD, and BoD-HVAC documentation prepared by Owner and Architect contains requirements that apply to this Section. SECTION 01815 - HVAC COMMISSIONING REQUIREMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division

More information

PIKES PEAK PARKING RESTORATION TABLE OF CONTENTS

PIKES PEAK PARKING RESTORATION TABLE OF CONTENTS 23 HEATING, VENTILATING AND AIR CONDITIONING TABLE OF CONTENTS TABLE OF CONTENTS DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING - Basic HVAC Requirements 238239.19 - Wall and Ceiling Unit Heaters

More information

PRIMARY UNIT SUBSTATIONS SECONDARY 1000 V AND ABOVE SECTION SECTION

PRIMARY UNIT SUBSTATIONS SECONDARY 1000 V AND ABOVE SECTION SECTION PRIMARY UNIT SUBSTATIONS SECONDARY 1000 V AND ABOVE PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install the primary unit substation(s) complete from the incoming line terminals to the

More information

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL SECTION 01815 - HVAC COMMISSIONING REQUIREMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division

More information

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents DIVISION 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN Contents 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION 13 00 60 LIST OF FIGURES... 6 Page 1 of 6 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN 1. General

More information

Technical Development Program

Technical Development Program TDP Catalog TDPs provide you with new technical training materials designed to help your contractors, engineers, and designers to effectively design, specify, sell, and apply HVAC equipment in commercial

More information