List of plant, machinery and list of test equipments available in house.

Size: px
Start display at page:

Download "List of plant, machinery and list of test equipments available in house."

Transcription

1 For Item code starting w i th 13 & 1 4 Transformer (Oil Filled/Dry Type): Details of supplies references of supplies made, for last three years, as per format A,B,C available in Annexure XVI duly notarized/certified by statutory in line EIL terms and condition Clause 3.0 ( along Performance feedbacks from end users in Hydrocarbon Industry/large industries (like Refinery, report (Short Circuit, Impulse, Temperature rise) not older that 5-years of largest rating of transformer from independent test laboratory. Sub-supplier list for raw material. List of plant and machinery and list of test equipments available in house. Maximum rating of transformer on which temperature rise test can be conducted in house. Details for the availability of test facility for Vacuum & Pressure testing of tank as per CBIP. Confirmation that the transformer winding shall be of copper only. Foil wound transformers are not acceptable. Motors (Safe area, n, FLP), Synchronous Machines, Alternators: Supply reference list of supplies made to Hydrocarbon Industry separately for safe area Motors, Hazardous area motors, synchronous machines and alternators as per format as per format A, B, C available in Annexure XVI (duly notarized/certified by statutory in line EIL terms and condition Clause 3.0 along with relevant documents ), for last three years. Performance feedback from end users in Hydrocarbon sector / large industries (like Refinery, Petrochemicals, Metallurgical Plants, Gas processing etc.) for one year satisfactory operation of each type of machine proposed for enlistment. For Hazardous area machines furnish details of Ex-n, Ex-d, Ex-p in a tabulated form, frame wise/kw wise clearly highlighting the latest certificates available indicating certifying/approval agency name, certificates Nos, dates etc.), latest code being followed for the complete range of Ex-d, Exn, Ex-d and Ex-p motors. Test certificate/report of each type to be furnished Details of valid approval of PESO Nagpur India for entire range of Ex-d, Exn, Ex-d and Ex-p motors. Sub-supplier list for raw material. List of plant, machinery and list of test equipments available in house.

2 Cables: Maximum rating of machine on which s test can be conducted in house by direct loading. Supply reference list of supplies made to Hydrocarbon Industry separately as per as per format A, B, C available in Annexure XVI (duly notarized/certified by statutory in line EIL terms and condition Clause 3.0 along with relevant documents ) for last three years. For enlistment it is mandatory to have performance feedbacks from end users for one year satisfactory operation of 100km charged Cables. 100km quantity Cable performance feedbacks for MV Power Cable (PVC insulated, PVC inner sheathed, Armoured and overall PVC sheathed) must include following: 1. Supplier should have supplied at least 100kms of Cable in last 5 years. 2. Supplier should have executed at least one order for 50Kms of cable. 3. At least, 10 kms cable should be of size 3.5 C X 300 sq. mm (considering Max. size procured by EIL) 4. Cable should Armoured type. 5. Cables should have been laid up & charged for one year. Same should be mentioned in end user feedback explicitly. reports as per applicable IS, from Recognized Third Party Lab Copy of valid BIS License. Short Circuit (S.C.) test report for MV and HV power cable as per applicable IS. Confirmation for in-house availability of wire drawing facility from Copper/Aluminum rods. Confirmation about in-house availability for Sequential Marking. Confirmation about in-house UPS availability for extruders Sub-supplier list for raw material (PVC Compound, Copper etc). Plant area and layout EHV Cables: Supply reference list of supplies made to Continuous Process Industry / Utilities along with relevant documents for the last three years. Details of supplies references of supplies made, for last three years, as per format A,B,C available in Annexure XVI duly notarized/certified by statutory in line EIL terms and condition Clause 3.0 ( along For enlistment, it is mandatory to have performance feedbacks from the end users for one year operation of 100 km charged Cables having working voltages from 66KV up to and including 220KV. In case, party intends to enlist for EHV cable of voltage grade less than 220KV, party shall have performance feedbacks from end users of one year operation of 100KM of charged cable of the voltage grade up to which enlistment is being sought.

3 Performance feedbacks for 100 km of EHV Cable (XLPE insulated, PVC/ PE inner sheathed, Armoured and overall FRLS PVC sheathed) must include following: 1. Supplier should have supplied at least 100 kms of Cable in last 5 years. 2. Supplier should have executed at least one order for 50 Kms of cable. 3. Cable should be Armoured type with FRLS PVC outer sheath, conductive graphite coated, lead or Aluminum Sheath to be provided along with Cu screening. 4. Cables should have been laid up & charged for one year. Same should be mentioned in end user feedback explicitly. 5. Supplier should have supplied at least 50 kms of cable of the maximum voltage grade & maximum size for which enlistment is being sought. reports as per applicable IS /IEC, from Recognized Third Party Lab Copy of valid BIS License. Short Circuit (S.C.) test report for EHV power cable as per applicable IS/IEC. (To be submitted with enlistment requests) Confirmation for in-house availability of wire drawing facility from Copper/Aluminum rods. Confirmation about in-house availability for Sequential Marking. Confirmation about in-house UPS availability for extruders Sub-supplier list for raw material (PVC Compound, Copper etc). Plant area and layout Calculations for sheath voltage/ current and the recommended method for metallic screen bonding. Switchboards-MV/HV, Details of supplies references of supplies made, for last three years, as per format A,B, C available in Annexure XVI (duly notarized/certified by statutory in line EIL terms and condition Clause 3.0 along Performance feedbacks from end users in Hydrocarbon Industry/large industries (like Refinery,

4 report as per applicable IS/IEC standard from Independent Test Lab /TPIA not older than five years. List of plant, machinery and list of test equipments available in house. Please state whether circuit breaker is manufactured in house or is a bought out item. Maximum current rating of which Temperature rise test can be conducted in house. Confirmation that in-house facilities for panel fabrication, painting, assembly and wiring are available. Furnish list of plant machinery for the same. Single Line Diagrams for the items for which end user feedback is submitted duly approved by end customer/consultant. UPS, Control panels, Drives, Battery Charger: Details of supplies references of supplies made, for last three years, as per format A,B, C available in Annexure XVI (duly notarized/certified by statutory in line EIL terms and condition Clause 3.0 along Performance feedbacks from end users in Hydrocarbon Industry/large industries (like Refinery, report as per applicable IS/IEC standard from Independent Test Lab /TPIA not older than five years. List of plant, machinery and list of test equipments available in house. Maximum current rating of which Temperature rise test can be conducted in house. Highest loading facilities available in terms of Voltage, kw, power factor (variation for regulation test ) Confirmation that in-house facilities for panel fabrication, painting, assembly and wiring are available. Furnish list of plant machinery for the same. Gas Insulated Switchgear EHV/HV: Details of references of the supplies made to Continuous Process Industry / Utilities for last three years, as per format A,B,C available in Annexure XVI duly notarized/certified by statutory in line EIL terms and condition Clause 3.0, along with relevant documents for offered models of complete GIS panels manufactured/assembled at proposed works with details of sourcing & sub assemblies of various equipment/ components (if sourcing of any equipment/ component is from overseas principals). Performance feedbacks from end users in Continuous Process Industry / Utilities for one year operation for offered models manufactured/ assembled at proposed works with details of sourcing & sub assemblies of various equipment/ components (if sourcing of any equipment/ component is from overseas principals). reports as per applicable IS/IEC standard from Independent Test Lab /TPIA not older than five years for the proposed ratings. The type test reports shall be for the GIS manufactured/ assembled & supplied from the proposed works with identical sourcing & subassemblies as being offered.

5 List of plant, machinery and list of test equipments available in house. Please state whether circuit breaker is manufactured/ assembled in house or is sourced from the principals. Maximum voltage rating, current rating & short circuit rating duly tested. Confirmation that in-house facilities for SF6 gas handling, panel fabrication, painting, assembly and wiring are available. Furnish list of plant machinery for the same. Single Line Diagrams & General arrangement drawings for the GIS for which end user feedback is submitted duly approved by end customer/consultant. Common Requirement for the items not mentioned above:- 1. Supply reference details of the supplies made in last three years, as per following format A,B,C available in Annexure XVI (duly notarized/certified by statutory in line EIL terms and condition Clause 3.0 along 2. Performance feedbacks from end users in Hydrocarbon Industry/large industries (like Refinery, Petrochemicals, Pipelines, Gas processing etc.) for one year satisfactory operation 3. Copy of evaluation / approval certificate from the authorities such as: IBR/BIS/CIMFR/PESO-CCE/FCRI/ERTL/ERDA/CPRI/ASME/API etc. whichever is applicable. 4. Responsibility Matrix as format PDD-RM STATUTORY REQUIREMENT:- AS PER INDIAN PETROLEUM RULES ELECTRICAL & INSTRUMENATATION EQUIPMENTS / ITEMS TO BE LOCATED IN HAZARADOUS AREA, NEED VALID APPROVAL OF PETROLEUM EXPLOSIVES SAFETY ORGANISATION). Note:- Refer Annexure XVI for various formats.

EHV XLPE CABLES CDCC LINE

EHV XLPE CABLES CDCC LINE PROFILE THE HINDUSTHAN VIDYUT PRODUCTS LIMITED, established in the year 1959 is a leading manufacturer of Overhead Conductors and Underground Cables. The Company at its Faridabad Works has sophisticated

More information

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE SEAL & SIGNATURE OF THE TENDERER PAGE 1 OF 14 TECHNICAL SPECIFICATION FOR LT XLPE POWER CABLES (SPECIFICATION NO.MM/I/LTXLPE/2006) 1. SCOPE: The specification

More information

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/LTPVC & CONTROL/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION

More information

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1 ANNEXURE TO TENDER NO. PUR42396GM DATED 06 th FEBRUARY 2014 SUPPLY OF 1.1KV GRADE LT POWER CABLES FOR THE PERIOD APRIL 2014 MARCH 2016 TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1 1.1 SCOPE

More information

MGVCL/MM/ 3Cx240 mm 2 XLPE Cables/2077 TECHNICAL SPECIFICATION FOR 11 KV XLPE POWER CABLE (CROSS LINKED POLYTHELENE DRY GAS CURED) SECTION I

MGVCL/MM/ 3Cx240 mm 2 XLPE Cables/2077 TECHNICAL SPECIFICATION FOR 11 KV XLPE POWER CABLE (CROSS LINKED POLYTHELENE DRY GAS CURED) SECTION I 1.1 SCOPE MGVCL/MM/ 3Cx240 mm 2 XLPE Cables/2077 TECHNICAL SPECIFICATION FOR 11 KV XLPE POWER CABLE (CROSS LINKED POLYTHELENE DRY GAS CURED) SECTION I 1.1.1 This Section of the Specification covers design,

More information

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath 0.6/1 kv LOW VOLTAGE CONTROL CABLES PVC OR XLPE INSULATED, PVC SHEATHED AS PER IEC 60502-1 Conductors Conductors shall be Circular Stranded, Class 2 as per IEC 60228, BS EN 60228. Upon request, Solid Circular

More information

SPECIFICATIONS FOR Gas-to-Cable termination

SPECIFICATIONS FOR Gas-to-Cable termination Product GSM-145 1.0 APPLICATION: Gas-to-cable termination is a part of high voltage gas insulated indoor switchgear equipment. The component is intended for a high voltage system of 132 kv (AC), 50 Hz.

More information

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 REVISION NO. 0 NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 PAGE NO. 1 OF 24 DATE OF ISSUE (MONTH/YEAR) TOTAL NO. OF PAGES (Including cover

More information

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE)

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE) Profile No.: 4 NIC Code: 27320 ELECTRICAL CABLES (SINGLE AND MULTICORE) 1. INTRODUCTION: Electrical Cables and wires are used for power distribution in electrical systems in housing sector as well as in

More information

26/35kV Copper XLPE Insulation Electric Cable

26/35kV Copper XLPE Insulation Electric Cable 26/35kV Copper XLPE Insulation Electric Cable Specifications 1.1~35kv XLPE insulated power cable 2.Standard: IEC,VDE,BS,UL,AS/NZS Black PVC sheath XLPE insulated armored copper power cable YJV22 YJV32

More information

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- T/0018/ DMRC-E-TR-CABLE-2 SPECIFICATIONS FOR 33 kv CABLES FOR ELEVATED AND Issued on: Date Stage

More information

SPECIFICATION FOR FRLS POWER CABLES

SPECIFICATION FOR FRLS POWER CABLES SPECIFICATION FOR FRLS POWER CABLES 1.0 SCOPE This specification cover the technical requirements of design, manufacture, testing and delivery to site of Power Cables of 1100V grade with FRLS PVC Sheathed,

More information

MATERIAL STANDARD FOR CABLES AND WIRES

MATERIAL STANDARD FOR CABLES AND WIRES MATERIAL STANDARD FOR CABLES AND WIRES CONTENTS : PAGE No. 1. SCOPE... 2 2. SERVICE CONDITIONS... 2 3. REFERENCES AND STANDARDS... 2 4. UNITS... 3 5. CABLE DESIGN AND CONSTRUCTION... 3 5.1 Applicable Cable

More information

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

NPS/002/020 Technical Specification for 11 & 20kV Power Cables Version:- 3.1 of Issue:- Nov - 09 Page 1 of 11 NPS/002/020 Technical Specification for 11 & 20kV Power Cables 1. Purpose The purpose of this document is to detail Northern Powergrid (the Company) requirements

More information

ELECTRICAL WORKS RELATED TO AC & UPS OF CMP GOC & IAD, LINGAMPALLY, HYDERABAD IN TWO BID SYSTEM THROUGH E-TENDER PRICE BID

ELECTRICAL WORKS RELATED TO AC & UPS OF CMP GOC & IAD, LINGAMPALLY, HYDERABAD IN TWO BID SYSTEM THROUGH E-TENDER PRICE BID SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. 3 rd Floor, Local Head Office,Bank Street, Koti, Hyderabad- 500095 On behalf of On behalf of On behalf of Cash Management Product GOC (CMP GOC) & Internal Audit

More information

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable. Spec. No. GO 5821-4361Rev.2 Issued date : July 13, 2005 Revised 1 date : April 29, 2015 Revised 2 date : February 19, 2016 Specification FOR 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated

More information

TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE

TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GETCO/E/TS

More information

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) EDC3 (5239) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table of Contents

More information

Construction guideline

Construction guideline 1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:

More information

New designed XLPE-insulated cables substituting paper-insulated pipe type cables

New designed XLPE-insulated cables substituting paper-insulated pipe type cables MODERN CABLE SYSTEMS IN STEEL PIPES New designed XLPE-insulated cables substituting paper-insulated pipe type cables Volker AUE, Nexans Deutschland Industries, Germany, Volker.Aue@nexans.com Wilfried ROSEBROCK,

More information

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables Version: 4.1 Date of Issue: February 2016 Page: 1 of 25 NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables 1. Purpose The purpose of this document is to detail the requirements

More information

TECHNICAL SPECIFICATION OF UNARMOURED FLAT 1100 VOLTS L.T. PVC INSULATED TWIN CORE 4.0mm² CABLE WITH ROUND ALUMINIUM CONDUCTOR BLACK SHEATHED.

TECHNICAL SPECIFICATION OF UNARMOURED FLAT 1100 VOLTS L.T. PVC INSULATED TWIN CORE 4.0mm² CABLE WITH ROUND ALUMINIUM CONDUCTOR BLACK SHEATHED. TECHNICAL SPECIFICATION OF UNARMOURED FLAT 1100 VOLTS L.T. PVC INSULATED TWIN CORE 4.0mm² CABLE WITH ROUND ALUMINIUM CONDUCTOR BLACK SHEATHED. I. SCOPE: This specification covers Manufacture, testing at

More information

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 ) 138-1: 2015 CEB SPECIFICATION AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 ) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0 Scope 3 2.0 System

More information

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES 11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE

More information

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE 137-1: 2015 CEB SPECIFICATION XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE CEYLON ELECTRICITY BOARD SRILANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0 Scope

More information

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES CEB STANDARD 030-1 : 1996 Specification for RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES CEYLON ELECTRICITY BOARD SRI LANKA Specification for RESIN FILLING TYPE JOINTING KITS FOR

More information

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables Version: 4.0 Date of Issue: October 2015 Page: 1 of 21 NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables 1. Purpose The purpose of this document is to detail the requirements

More information

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE TI 20 PVC TI 20 INSULATED TELEPHONE WIRE Standard: Nominal voltage: Temperature range - fixed laying: Cable Structure: Application: Packing: 2x0,5 0,4 2,6 3,6 7,2 2x0,6 0,4 2,8 5,2 9,1 2x0,8 0,4 3,2 9,2

More information

U.V resistance UL Sunlight Resistance. Flame retardant IEC

U.V resistance UL Sunlight Resistance. Flame retardant IEC Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial

More information

Technical Specification for Insulated Low Voltage Single Core Copper Cable

Technical Specification for Insulated Low Voltage Single Core Copper Cable Ergon Energy Corporation Limited Technical Specification for Insulated Low Voltage Single Core Copper Cable ETS03-01-03 Specification ETS03-01-03 Ver 3 Contents 1. Purpose and Scope... 1 2. References...

More information

Insulated sheath power cable systems

Insulated sheath power cable systems PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Engineering Recommendation C55 Insulated sheath power cable systems www.energynetworks.org PUBLISHING AND COPYRIGHT INFORMATION 2014

More information

Aluminium Excellence Performance in Economical Way

Aluminium Excellence Performance in Economical Way OPPER CLAD Aluminium Excellence Performance in Economical Way www.jmv.co.in Leading The Nation Towards Electrical Safety With the growing industrialization, the demand of electrical safety is increasing

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-2 Second edition 2005-03 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 2: Cables

More information

It is standard practice and all manufacturers to abide by this. It is standard practice and all manufacturers to abide by this.

It is standard practice and all manufacturers to abide by this. It is standard practice and all manufacturers to abide by this. 1 162 General 2 162 General We recommend to specify door handle to singe shot latch type, bolted construction of Door shall not be acceptable. Closing and Tripping Coils shall be rated for continuous supply,

More information

2. RATED VOLTAGE: The rated voltage of the AB cables shall be 1100 volts

2. RATED VOLTAGE: The rated voltage of the AB cables shall be 1100 volts TECHNICAL SPECIFICATION OF LT AERIAL BUNCHED CABLES FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY) (Size 1C x35mm²+1c x16 + 25mm² and 2C x50mm² +1Cx25 + 35mm²) 1. SCOPE: This specification

More information

40/69 kv to 127/220 kv XLPE

40/69 kv to 127/220 kv XLPE high voltage catalog Electrical Cables 40/69 kv to 17/0 kv XLPE Stranded copper conductor Copper wire screen Swellable tape Aluminum tape PE outer jacket Semi-conductive swellable tape Outer semi-conductive

More information

SUPPLY ERECTION TOTAL RATE AMOUNT RATE AMOUNT AMOUNT (Rs.) (Rs.) (Rs.) (Rs.) (Rs.)

SUPPLY ERECTION TOTAL RATE AMOUNT RATE AMOUNT AMOUNT (Rs.) (Rs.) (Rs.) (Rs.) (Rs.) SBI-AO2 Project Residency Rd Br-elect/RBO-4 SCHEDULE OF QUANTITIES FOR ELECTRICAL WORKS. DATE : 24/4/2018 Sl. No. DESCRIPTION OF WORK UNIT QTY 1 READYMADE FINAL DISTRIBUTION BOARDS Supply, Instillation,

More information

P.V.C. INSULATED UNARMOURED COPPER CABLES

P.V.C. INSULATED UNARMOURED COPPER CABLES 083 : 2007 CEB SPECIFICATION P.V.C. INSULATED UNARMOURED COPPER CABLES CEYLON ELECTRICITY BOARD SRI LANKA Specification for P.V.C. INSULATED UNARMOURED COPPER CABLES CEB Specification 083 : 2007 CEYLON

More information

XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES

XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES XLPE MATERIAL The trend of cross-linked polyethylene insulated cables into power cables field is quite prevalent in the world as the substitutes of paper insulated cables, which had played the leading

More information

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT CEB SPECIFICATION 005-1: 2012 P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS PAGE 1. Scope 03

More information

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES-T/0017/DMRC-E-PS-CABLE-01 SPECIFICATIONS FOR EHV 220kV/132kV/110kV/66kV Power Cables Issued on:

More information

5.2 The phase conductors shall be provided with one, two & three ridges for easy identification.

5.2 The phase conductors shall be provided with one, two & three ridges for easy identification. LT Aerial Bunched Cables for LT Lines (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY) 1. SCOPE: This specification covers XLPE insulated Aluminum cable twisted over a central bare Aluminum Alloy

More information

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained. SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF CROSSLINKED POLYETHYLENE INSULATED THERMOPLASTIC SHEATHED CABLES FOR WORKING VOLTAGES UPTO AND INCLUDING 1100 VOLTS ACCORDING TO IS 7098(Part 1):1988

More information

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR PART 1 - GENERAL Section 26 05 15 SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR 1.1 Cable shall be 15 kv, shielded, three conductor with ground, stranded copper, with continuously welded and corrugated

More information

GEMSCAB INDUSTRIES LIMITED STANDARD PLAN FOR HT XLPE CABLES AS PER IS:7098(PART-II)

GEMSCAB INDUSTRIES LIMITED STANDARD PLAN FOR HT XLPE CABLES AS PER IS:7098(PART-II) -1 RAW MATERIAL INSPECTION 1.1 ALUMINIUM ROD/COPPER ROD (i) Diameter 100% IS:5484 & IS:613 IS:5484 & IS:613 GIL-GIR-006 IQC (ii) Conductivity or resistivity 100% IS:5484 & IS:613 IS:5484 & IS:613 GIL-GIR-006

More information

SECTION EARTHING AND EARTH FAULT PROTECTION

SECTION EARTHING AND EARTH FAULT PROTECTION SECTION 16660 PART 1 - GENERAL 1.01 DESCRIPTION A. The work to be performed includes, but is not necessarily limited to, all work involved with the construction and assembly of a complete electrical earthing

More information

SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY)

SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY) SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x16 + 25mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY) 1. SCOPE: This specification covers XLPE insulated

More information

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable Ergon Energy Corporation Limited Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable ETS03-01-05 Specification ETS03-01-05 Ver 4 Contents 1. Purpose and Scope... 1 2. References...

More information

CCC Services for oil-filled- and XLPE-Cable Systems

CCC Services for oil-filled- and XLPE-Cable Systems sc CCC Services for oil-filled- and XLPE-Cable Systems Service Programme for Cable Systems As a supplier of MV- and HV-cable systems with several decades of experience, CCC GmbH Berlin offers the full

More information

KEMA INSPECTION REPORT

KEMA INSPECTION REPORT KEMA INSPECTION REPORT 3190-15 Object Power cable system consisting of a single core power cable, outdoor termination, GIS termination and a joint 127/220 (245) kv 1x1000 mm 2 Cu XLPE Client GAON Cable,

More information

B. Provide liquid-filled secondary substation transformers as indicated on drawings.

B. Provide liquid-filled secondary substation transformers as indicated on drawings. SECTION 26 12 13 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 26 05 00. B. Provide liquid-filled secondary substation transformers as indicated on drawings. 1.02 RELATED

More information

Paragraph/ Figure/Table

Paragraph/ Figure/Table Date Document No. 22-07-2014 Doc: ET 15(6749) Sl. No. Name of the Organization Clause/ Subclause Paragraph/ Figure/Table Type of Comment (General/ Technical/ Editorial Comments Proposed Change BUREAU OF

More information

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE METAL-ENCLOSED BUS MEDIUM VOLTAGE PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install the equipment as specified herein and as shown on the contract drawings. The medium

More information

Transnet Limited Trading as Transnet Freight Rail. Adress Infrastructure Building, 227 Mark street, Vryheid, 3100

Transnet Limited Trading as Transnet Freight Rail. Adress Infrastructure Building, 227 Mark street, Vryheid, 3100 Contract Data The Employer is Name Transnet Limited Trading as Transnet Freight Rail Adress Infrastructure Building, 227 Mark street, Vryheid, 3100 Telephone (034) 989 9446 Fax No. (034) 989 9433 E-mail

More information

PART 7 Technical Specification for Overhead and Underground Service Connection works for the Year

PART 7 Technical Specification for Overhead and Underground Service Connection works for the Year PART 7 Technical Specification for Overhead and Underground Service Connection works for the Year 2016-17 Technical Specification for Overhead and Underground Service Connection works for the Year 2016-17

More information

I. CLARIFICATIONS SOUGHT BY PROSPECTIVE BIDDERS

I. CLARIFICATIONS SOUGHT BY PROSPECTIVE BIDDERS This clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows: I. CLARIFICATIONS SOUGHT BY PROSPECTIVE BIDDERS S. No. 1. Refer to section Bid Data Sheet

More information

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS. 66 kv LIGHTNING ARRESTORS

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS. 66 kv LIGHTNING ARRESTORS GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR 66 kv LIGHTNING ARRESTORS GETCO/ENGG/TECH SPECI.- 66 KV LA/R4/Jan11 Sign

More information

VOLUME-2 (PRICE BID) FOR TENDER NO. NABI/7(171)/2019-WORKS

VOLUME-2 (PRICE BID) FOR TENDER NO. NABI/7(171)/2019-WORKS VOLUME-2 (PRICE BID) FOR TENDER NO. NABI/7(171)/2019-WORKS NAME OF WORK- Supply, Installation, Testing & Commissioning of 200kVA/KW Modular Uninterruptible Power Supply(UPS) system for Central Instrumentation

More information

NPS/002/023 Technical Specification for 132kV Power Cables.

NPS/002/023 Technical Specification for 132kV Power Cables. Version:- 2.2 of Issue:- June 09 Page 1 of 11 NPS/002/023 Technical Specification for 132kV Power Cables. 1. Purpose The purpose of this document is to detail the technical requirements of Northern Powergrid

More information

PARTICULAR SPECIFICATION E11: GENERAL ELECTRICAL EARTHING AND LIGHTNING PROTECTION

PARTICULAR SPECIFICATION E11: GENERAL ELECTRICAL EARTHING AND LIGHTNING PROTECTION E11 : General Electrical Earthing and LIGHTNING Protection PARTICULAR SPECIFICATION E11: GENERAL ELECTRICAL EARTHING AND LIGHTNING PROTECTION 1 2009-05-12 Review of Mechanical / Electrical and Control

More information

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE Engineering Specification Electrical Networks L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM OR COPPER CONDUCTOR 3.8/6.6kV XLPE INSULATED WITHOUT METALLIC SCREEN PVC Version:

More information

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.

More information

1. All Members of Power Cables Sectional Committee, ET 09; 2. All Members of Electrotechnical Division Council; and 3. All other Interested.

1. All Members of Power Cables Sectional Committee, ET 09; 2. All Members of Electrotechnical Division Council; and 3. All other Interested. DRAFT IN WIDE CIRCULATION DOCUMENT DESPATCH ADVICE Reference Date ET 09/T-45 03-05-2011 TECHNICAL COMMITTEE ETD 09 --------------------------------------------------------------------------------------------------------------

More information

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR 458 7.3.1 11 KV Cables 7.3.1.1 General Where a Manufacturer s Standard or a national Standard equal to or better than the appropriate specified

More information

CCC-Serv-8oil_ eng* :39 Uhr Seite 9. CCC Services for oil-filled- and XLPE-cable systems

CCC-Serv-8oil_ eng* :39 Uhr Seite 9. CCC Services for oil-filled- and XLPE-cable systems CCC-Serv-8oil_533-09-2003-eng* 28.02.2005 16:39 Uhr Seite 9 sc CCC Services for oil-filled- and XLPE-cable systems CCC-Serv-8oil_533-09-2003-eng* 28.02.2005 16:39 Uhr Seite 2 Contact: CCC GmbH Berlin Cable

More information

9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA

9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA 9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA Technical specification for 9KV/18KV 5KA Metal oxide Lightning Arrestors without Gap. ----------------------------------------------------------------------------------------------------------------

More information

11-SDMS-01 REV. 03 ( )

11-SDMS-01 REV. 03 ( ) 11-SDMS-01 REV. 03 (19-07-2018) SPECIFICATION FOR LOW-VOLTAGE POWER AND CONTROL CABLES Saudi Electricity Company 1. SCOPE... 3 2. CROSS REFERENCES TO OTHER SEC STANDARDS... 3 3. APPLICABLE CODES AND STANDARDS...

More information

Excellence Through Experience

Excellence Through Experience Excellence Through Experience VI D YA VIDYA WIRES PVT. LTD. (An ISO 9001 : 2008 Certified Company) QUALITY ASSURED COMPANY Enamelled Copper Wires and Strips Insulated copper conductors COMPANY PROFILE

More information

NPS/002/017 Technical Specification for 66 kv and 132 kv Cable Accessories

NPS/002/017 Technical Specification for 66 kv and 132 kv Cable Accessories Version:- 4.0 Date of Issue:- October 2016 Page 1 of 21 NPS/002/017 Technical Specification for 66 kv and 132 kv Cable Accessories 1. Purpose The purpose of this document is to detail the technical requirements

More information

TABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4

TABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4 TITLE SPECIFICATION FOR FREE- STANDING 11 DATE: AUGUST 2006 PAGE: 1 OF 15 TABLE OF CONTENTS Page FOREWORD... Error! Bookmark not defined. INTRODUCTION...3 1 SCOPE...3 2 NORMATIVE S...3 3 DRAWING...4 4

More information

Single Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Single Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable Edition Nº: 7 NPS - 96 Issued date: June, 2017 LV, single core, Aluminum, XLPE Power Cable THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS - 96 for Single Core, Aluminum Conductor Extruded Cross

More information

a) Temperature Variation : 5ºC to 55ºC b) Relative humidity : Upto 95% c) Altitude : 0 to 1000 Mtrs. d) No.of tropical monsoon months : 3 (Three)

a) Temperature Variation : 5ºC to 55ºC b) Relative humidity : Upto 95% c) Altitude : 0 to 1000 Mtrs. d) No.of tropical monsoon months : 3 (Three) TECHNICAL SPECIFICATION OF UNARMOURED 1100 VOLTS L.T.PVC INSULATED 4 CORE 6mm², 10mm², 16mm² PVC INSULATED PVC SHEATHED CABLE WITH CIRCULAR ALUMINIUM CONDUCTOR: I. SCOPE: This specification covers Manufacture,

More information

POLYMER HOUSED SURGE ARRESTORS

POLYMER HOUSED SURGE ARRESTORS POLYMER HOUSED SURGE ARRESTORS March 2015 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091.

More information

SECTION SECONDARY UNIT SUBSTATIONS SECONDARY LESS THAN 1000 V

SECTION SECONDARY UNIT SUBSTATIONS SECONDARY LESS THAN 1000 V SECONDARY UNIT SUBSTATIONS SECONDARY LESS THAN 1000 V PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the secondary unit substation(s) complete from the incoming line terminals

More information

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES Nigel Hampton Copyright GTRC 2012 Objective To present the evolution of cables in time to understand the lessons from the past: the legacy problems and

More information

SPECIFICATION SHEET JUNCTION BOXES

SPECIFICATION SHEET JUNCTION BOXES SPECIFICATION SHEET JUNCTION BOXES 8484-SS8201-8010 0 DOCUMENT NO REV SHEET 1 OF 1 CLIENT : HPCL, MUMBAI PROJECT : LPG BOTTLING PLANT, ANANTAPUR PLANT : - LPG BOTTLING PLANT ISSUED FOR : PROPOSAL ENQUIRY

More information

DEVELOPMENT OF HIGH VOLTAGE EXTRUDED CABLES: THE ITALIAN EXPERIENCE

DEVELOPMENT OF HIGH VOLTAGE EXTRUDED CABLES: THE ITALIAN EXPERIENCE DEVELOPMENT OF HIGH VOLTAGE EXTRUDED CABLES: THE ITALIAN EXPERIENCE Antonio FARA, ENEL SpA, (Italy), antonio.fara@enel.it Ernesto ZACCONE, Prysmian SpA, (Italy), ernesto.zaccone@prysmian.com ABSTRACT High

More information

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable Edition Nº: 9 THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS-76 for Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable for Rated Voltage U0/U = 0.6/1.0

More information

56-SDMS-01 REV. 01 SPECIFICATIONS FOR

56-SDMS-01 REV. 01 SPECIFICATIONS FOR 56-SDMS-01 REV. 01 SPECIFICATIONS FOR 13.8KV UNIT SUBSTATIONS This specification is property of SEC and subject to change or modification without any notice CONTENTS PAGE No. 1.0 SCOPE 3 2.0 CROSS REFERENCES

More information

SECTION 07. TECHNICAL SPECIFICATIONS OF 11 KV XLPE CU CABLE (1x500 mm 2 )

SECTION 07. TECHNICAL SPECIFICATIONS OF 11 KV XLPE CU CABLE (1x500 mm 2 ) SECTION 07 TECHNICAL SPECIFICATIONS OF 11 KV XLPE CU CABLE (1x500 2 ) TECHNIC A L SPE C IFIC A TIO NS/RE Q UIRE ME NTS O F 11 KV XLPE C U C A B LE (1x500 2 ) 7.1 GE NE RAL: This section of the document

More information

TECHNICAL SPECIFICATION FOR SUPPLY 220KV,1C,XLPE POWER CABLE FOR TRANSMISSION LINES & SUB-STATIONS

TECHNICAL SPECIFICATION FOR SUPPLY 220KV,1C,XLPE POWER CABLE FOR TRANSMISSION LINES & SUB-STATIONS GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATION FOR SUPPLY 220KV,1C,XLPE POWER CABLE FOR TRANSMISSION LINES & SUB-STATIONS

More information

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are

More information

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)

More information

SPECIFICATION CUM COMPLIANCE CERTIFICATION FOR PRESSURE TESTING PUMP

SPECIFICATION CUM COMPLIANCE CERTIFICATION FOR PRESSURE TESTING PUMP BHARAT HEAVY ELECTRICAL LIMITED Enquiry No. : UNIT'S ADDRESS Due Date : UNIT'S PHONE NOS. Supplier Qtn. No.: CONTACT PERSON'S NAME/DESIGN./PHONE NO. Date : E-MAIL (FROM PURCHASE DEPTT.) NOTE:- SPECIFICATION

More information

TECHNICAL SPECIFICATIONS FOR CROSS LINKED POLYETHYLENE INSULATED 3 CORE llkv CABLES

TECHNICAL SPECIFICATIONS FOR CROSS LINKED POLYETHYLENE INSULATED 3 CORE llkv CABLES TECHNICAL SPECIFICATIONS FOR CROSS LINKED POLYETHYLENE INSULATED 3 CORE llkv CABLES 1.00.00 SCOPE: 1.01.00 The scope of this package, covers the design, manufacture, stage inspection at works, inspection

More information

úê üßµö ÖãÆü ü ¾Ö³ÖÖÖ - III

úê üßµö ÖãÆü ü ¾Ö³ÖÖÖ - III Subject: Implementation of IS/IEC 60947-2:2003 due to revision of IS 13947 series of specifications as IS/IEC 60947 series 1. ETD has informed regarding the publication of the series of specifications

More information

33-SDMS-02 SPECIFICATIONS FOR

33-SDMS-02 SPECIFICATIONS FOR SPECIFICATIONS FOR MV AUTOMATIC LINE SECTIONLIZER UP TO 36 KV This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS SECTION T I T L E PAGE NO.

More information

Status - Indian Electrical Industry April to March

Status - Indian Electrical Industry April to March Status - Indian Electrical Industry April to March 2016-2017 Source: CEA & MNRE 112% achievement with Thermal power achieving 127% addition on planned Generation 60% achievement with power achieving 104%

More information

37-SDMS-01 REV. 03 SPECIFICATIONS FOR

37-SDMS-01 REV. 03 SPECIFICATIONS FOR 37-SDMS-01 REV. 03 SPECIFICATIONS FOR LOW VOLTAGE MOLDED CASE CIRCUIT BREAKERS FOR SERVICE CONNECTIONS This specification is property of SEC and subject to change or modification without any notice CLAUSE

More information

Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable Issued date: June, 2017 THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS-77 for Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable for Rated Voltage

More information

Heating Cables DATASHEET

Heating Cables DATASHEET Heating Cables DATASHEET JUNHO 2013 M PSBL system Heating cable PSBL Features Self-limiting Can be used in explosive athmospheres without temperature limiter Can be cut to any length due to parallel power

More information

PRY-MOULD. High Voltage Accessories for Extruded Cables

PRY-MOULD. High Voltage Accessories for Extruded Cables PRY-MOULD High Voltage Accessories for Extruded Cables Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy

More information

Dr. Panchanana Khuntia

Dr. Panchanana Khuntia Dr. Panchanana Khuntia Department of Physics Indian Institute of Technology Madras Chennai-600036 Dr. Panchanana Khuntia Project Coordinator Tel: +91-44-2257 4847 Email: pkhuntia@iitm.ac.in Fax: +91-44

More information

TECHNICAL SPECIFICATION FOR. L.T.XLPE POWER CABLE (armoured) FOR DISTRIBUTION NETWORK

TECHNICAL SPECIFICATION FOR. L.T.XLPE POWER CABLE (armoured) FOR DISTRIBUTION NETWORK Specification No.CSC-115/R-1/DH/UH/P&D/2016-17 TECHNICAL SPECIFICATION FOR L.T.XLPE POWER CABLE (armoured) FOR DISTRIBUTION NETWORK For sizes 1CX10, 16, 35, 50, 95, 120, 150, 185,240, 300, 400,500 & 630mm2

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

Procurement of Operational Spares - 69/13.8kV Substations Contract Number GPL - PI ADDENDUM No. 1

Procurement of Operational Spares - 69/13.8kV Substations Contract Number GPL - PI ADDENDUM No. 1 March 08, 2016 Prospective Bidders Procurement of Operational Spares - 69/13.8kV Substations Contract Number GPL - PI - 018-2016 ADDENDUM No. 1 Please find attached an addendum on the above contract. This

More information

SQ. MM. 1 CORE 2 CORE 3 CORE 3.5 CORE 4 CORE

SQ. MM. 1 CORE 2 CORE 3 CORE 3.5 CORE 4 CORE PRICE LIST 4 PVC/XLPE ARMOURED CABLES DATED : 1st NOVEMBER 2018 PVC / XLPE ARMOURED Cables with COPPER Conductor 1100 V. Grade confirming to IS : 7098 (Pt-1) 1988 PVC/XLPE ARMOURED Cables with ALUMINIUM

More information

INVITATION FOR QUOTATION. TEQIP II/2012/WB2G02/Shopping/41

INVITATION FOR QUOTATION. TEQIP II/2012/WB2G02/Shopping/41 INVITATION FOR QUOTATION TEQIP II/2012/WB2G02/Shopping/41 25 Sep 2012 To, Science India 232 B,Acharya Prafulla Chandra Road Kolkata 700 004 Sub: Invitation for Quotations for supply of Goods Package Code:

More information

T. SUNDUPALLI BRANCH (04427)

T. SUNDUPALLI BRANCH (04427) STATE BANK OF INDIA T. SUNDUPALLI BRANCH (04427) REGION 2, KADAPA RURAL TIRUPATI (A.O) ELECTRICAL WORK BILL OF QUANTITIES SL. NO. DESCRIPTION QTY. UNIT RATE AMOUNT Rs. Rs. 1 Supply, installation, testing

More information

Comparison of BS 5308, PAS 5308 and BS EN

Comparison of BS 5308, PAS 5308 and BS EN Comparison of BS 5308, PAS 5308 and BS EN 50288 Scope BS 5308 Part 1: 1986- Instrumentation Cables Part 1. Specification for Polyethylene Insulated Cables (withdraw, superseded by BS EN 50288-7) BS 5308

More information