2 2
3 TORAY RAYTELA Structure Product 1. Fiber Cladding 2. Cord A. Simplex B. Duplex Fiber 3. Cable A. Simplex B. Duplex Tension Member Cord 4. Light Guide Fiber KE1619-PC6 3
4 4
5 TORAY RAYTELA Structure PE series (Polymethyl Methacrylate) Cladding (Fluorinated Polymer) Specifications Parameter Performance Material Polymethyl Methacrylate (PMMA) Refractive index 1.49 Cladding Material Fluorinated Polymer Refractive index profile Step index Numerical aperture (NA) 0.58 Acceptance angle 71 Available temperature range Permanent use Cord Product List Fiber/ (mm) Number of Fibers Material Allowable Bending Radius (mm) PES-CD501-10H 0.5/1.0 1 PE PES-CD H 1.0/2.2 1 PE PES-CD A 1.0/1.5 1 PA 1, KE1619-PE4 5
6 TORAY RAYTELA Structure PF series (Polymethyl Methacrylate) Cladding (Fluorinated Polymer) Specifications Parameter Performance Material Polymethyl Methacrylate (PMMA) Refractive index 1.49 Cladding Material Fluorinated Polymer Refractive index 1.42 Refractive index profile Step index Numerical aperture (NA) 0.46 Acceptance angle 55 Available temperature range Permanent use Fiber Product List Cladding Allowable Bending Radius (mm) PFU-FB , PFU-FB , PFU-FB ,000 1,500 5, KE1619-PF6 6
7 Cord Product List Fiber/ (mm) Number of Fibers Material Allowable Bending Radius (mm) PFU-CD E 0.5/1.0 1 PE PFU-CD E 0.5/1.5 1 PE PFU-CD E 0.75/1.8 1 PE PFU-CD E 0.75/2.2 1 PE PFU-CD E 1.0/2.2 1 PE 500 1, PFU-UD E 1.0/2.2 1 PE 500 UL Grade VW-1 1, PFU-UD V 1.0/2.2 1 PVC 500 UL Grade VW-1 1, PFU-CD E 0.5/1.0 (2.0) 2 PE PFU-CD E 0.5/1.5 (3.0) 2 PE PFU-CD E 0.75/1.8 (3.6) 2 PE PFU-CD E 0.75/2.2 (4.4) 2 PE PFU-CD E 1.0/2.2 (4.4) 2 PE PFU-UD E PFU-UD V Cable Product List 1.0/2.2 (4.4) 2 1.0/2.2 (4.4) 2 Fiber/Cord/ Cable (mm) Number of Fibers PFU-CL E50VT 1.0/2.2/5.0 1 PFU-CL E60VT 1.0/2.2 (4.4) /6.0 2 PE UL Grade VW-1 PVC UL Grade VW-1 Cord/Cable Material PE/Soft PVC With KEVLAR PE/Soft PVC With KEVLAR Allowable Bending Radius (mm) KE1619-PF6 7
8 8
9 TORAY RAYTELA Structure PG series (Polymethyl Methacrylate) Cladding (Fluorinated Polymer) Specifications Parameter Performance Material Polymethyl Methacrylate (PMMA) Refractive index 1.49 Cladding Material Fluorinated Polymer Refractive index 1.41 Refractive index profile Step index Numerical aperture (NA) 0.50 Acceptance angle 60 Available temperature range Permanent use Fiber Product List Cladding Allowable Bending Radius (mm) PGS-FB ,000 PGR-FB PGU-FB ,000 PGR-FB PGU-FB 750 2, PGR-FB 750 9, PGU-FB1000 1, ,000 PGR-FB1000 5, PGU-FB ,480 1, PGR-FB PGR-FB2000 1,980 2, PGR-FB3000 2,980 3, KE1619-PG6 9
10 Cord Product List Fiber/ (mm) Number of Fibers Material Allowable Bending Radius (mm) PGU-CD E /1.0 1 PE 500 PGS-CD E PGU-CD E 0.5/1.5 1 PE PGU-CD E 0.75/1.8 1 PE PGU-CD E /2.2 1 PE 500 PGS-CD E PGU-CD E /2.2 1 PE PGS-CD E 1, PGU-CD E /2.2 1 PE 600 PGS-CD E PGU-CD E PGS-CD E 1.5/2.8 1 PE PGR-CD E PGU-CD E /3.0 1 PE 300 PGR-CD E PGU-CD E /1.0 (2.0) 2 PE 500 PGS-CD E PGU-CD E 0.5/1.5 (3.0) 2 PE PGU-CD E 0.75/1.8 (3.6) 2 PE PGU-CD E 0.75/2.2 (4.4) 2 PE PGU-CD E /2.2 (4.4) 2 PE 500 PGS-CD E Light Guide Product List Fiber/ (mm) Number of Fibers Material PGS-LG265-4 E /1.0 4 PE PGS-LG265-8 E /1.3 8 PE PGS-LG265-16E / PE PGS-LG265-32E / PE PGS-LG265-48E / PE PGS-LG265-64E / PE PGS-LG500-32E42 0.5/ PE Cable Product List Fiber/Cord/ Cable (mm) Number of Fibers Cord/Cable Material Allowable Bending Radius (mm) PGS-CL E50V 1.0/2.2/5.0 1 PE/Soft PVC KE1619-PG6 10
11 TORAY RAYTELA Structure PK series (Polymethyl Methacrylate) Cladding (Fluorinated Polymer) Specifications Parameter Performance Material Polymethyl Methacrylate (PMMA) Refractive index 1.49 Cladding Material Fluorinated Polymer Refractive index profile Step index Numerical aperture (NA) 0.5 Acceptance angle 60 Available temperature range Permanent use Fiber Product List Fiber PK-FB1000 1,000 1,500 5,250 (db/m ) 0.20 KE1619-PK4 11
12 Structure TORAY RAYTELA Side Light Plastic Optical Fiber PS series A. Fiber Products B. Light Tube Products (Polymethyl Methacrylate) Cladding (Fluorinated Polymer) Fiber (PS series) (Translucent Polyethylene) Specifications Parameter Performance Material Polymethyl Methacrylate (PMMA) Refractive index 1.49 Cladding Material Fluorinated Polymer Refractive index profile Step index Numerical aperture (NA) 0.46 Acceptance angle 55 Fiber Product List Fiber PS-FB ,000 PS-FB ,000 PS-FB ,700 9,000 PS-FB1000 1,000 1,500 5,250 Light Tube Product List Fiber/ (mm) Number of Fibers PS-LT250-4 E / Translucent PE 500 PS-LT250-7 E / Translucent PE 500 PS-LT250-16E / Translucent PE 500 KE1606-PS5 12
13 13
14 Handling Precautions Products Please follow the guidelines stated below when handling Toray Raytela Plastic Optical Fiber fibers, cord, cables and other processed items. (hereinafter referred to as Raytela Optical Fiber) Safety Precautions Usage Precautions Raytela Optical Fiber shall under no circumstance come into direct contact with food, nor shall it be used inside the human body Design Precautions When designing a system using Raytela Optical Fiber, be sure to fully review the Raytela Optical Fiber characteristics, as described in the technical manuals before usage. The characteristics shown in the technical manuals do not guarantee the safety and adaptability of the product. Please confirm the safety and adaptability of the products according to the intend use of the products. Usage Do not use the fiber under extreme temperatures. Refer to the individual Raytela Optical Fiber technical specification sheets, for operational temperature requirements. If the temperature exceeds 200, there is a danger of gas emitting and/or ignition from the decomposition of the fiber. When a halogen lamp or condensed sunbeams are used as a light source, a heat cut filter or cooling device needs to be used to prevent the temperature from rising past the limit of the fiber. Avoid usage in dusty, dirty places. If dust and/or dirt adheres to the terminals of Raytela Optical Fiber, the optical characteristics of the fiber may deteriorate. Furthermore, Raytela Optical Fiber may melt and/or burn by igniting dust under high temperature conditions. Disposal Precautions Raytela Optical Fiber contains fluorocarbon resin. Some products are also sheathed in vinyl chloride resin. When incinerated, such products may generate corrosive and poisonous hydrogen fluoride gas or hydrogen chloride gas. When disposing, incinerate in an acid-resistant incinerator equipped with a toxic substance remover/filter, or commission an industrial waste treatment specialist to bury them. It is necessary to observe the laws and regulations of the country or providence where the fiber is to be incinerated or buried for disposal. 06/16 / V3 / HW / toray/pof-katalog How to get the most performance out of Raytela Optical Fiber Precautions against physical environmentalfactors Do not apply force that exceeds the maximum allowable tension factor. Do not bend the fiber in a tight arc. If excessive stress is applied, especially near the connectors, optical characteristics may deteriorate. The radius of the arc in which the fiber is bent should not be less than the equivalent of 20 times the outside diameter of the fiber. Do not apply tight twists to Raytela Optical Fiber. The optical characteristics of Raytela Optical Fiber will decline if used while being twisted. In addition to the above, avoid applying excessive force, repetitive bending, and dropping. Precautions against chemical environmental factors Do not bring Raytela Optical Fiber into contact with plasticizers (Phthalate, etc.) and/or soft PVC material (including: electric wire jacket, vinyl tape etc.). Plasticizers may move thus, the optical characteristics may deteriorate. Please test in advance to check for negative effects. When Raytela comes in contact with detergents, adhesives, oils, solvents and other chemicals, the optical characteristics may deteriorate. Verification of the resistance of Raytela against these chemicals should be confirmed in the technical specification manuals. Precautions against other environmental factors Under high moisture conditions, to maintain the quality of the fiber, it is necessary to devise a cable that will keep excessive moisture out of Raytela Optical Fiber. Avoid using Raytela Optical Fiber in environments where it will be exposed to ultraviolet rays, radioactive rays and other special energy rays. The typical data contained herein are for general reference use only and are not expressed guarantees. The information is based on tests believed to be reliable but each user should conduct his own tests to determine the suitability of TORAY optical fiber in his own particular applications. All information in this guide is subject to change without prior notice. 14
Zipcord 2.2mm Plastic Optical Fiber Cable Specifications. Fiber types Core Polymethyl Methacryate(PMMA) Pluorinated Polymer
POF 란 (Plastic Optical Fiber) 광섬유의코어재료로유리대신플라스틱을사용한광케이블. 기존의유리섬유광케이블 (GOF:Glass Optical Fiber) 에비하여유연성이뛰어나고, 코아직경이굵어시공이쉬울뿐아니라, 가격이저렴하다. 특히최근에개발상용화된불소수지코어지름의플라스틱광케이블 (POF) 은 100m 까지 10Gbps, 500m까지 2.5Gbps
More informationHANDLING AND INSTALLATION INSTRUCTION FOR. DiTeSt SMARTprofile
HANDLING AND INSTALLATION INSTRUCTION FOR DiTeSt SMARTprofile 1 How to install DiTeSt PE SMARTprofile Thank you for purchasing PE SMARTprofile - distributed deformation and temperature sensor. This brochure
More informationKOERU STATIC-DISSIPATIVE PLASTIC PANELS
PVC KOERU Static-Dissipative Plastic Panels Globally, professional manufacturing industries and research facilities have a high-level requirement towards maintaining dust-free environments. Frequently,
More informationRaychem Safety Data Sheet
1. IDENTIFICATION OF SUBSTANCE OR PREPARATION Page 1 of 5 PRODUCT APPLICATION Raychem Heat-Shrinkable Interconnections with Solder for Low Temperature Wire This Safety Data Sheet applies to the following
More informationWIRING METHODS CHAPTER 38
CHAPTER 38 WIRING METHODS SECTION E3801 GENERAL REQUIREMENTS E3801.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3801.2
More informationFiber Cable Construction
White Paper January, 2013 OL-TA-002B-E 2016 Olabs Technology Company Limited. All rights reserved. Contents 1. Introduction... 3 2. Cable Jacket Ratings... 4 3. Cable Construction... 5 2 2016 Olabs Technology
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 15 2006 (Formerly IPS SP 100) Specification for Trunk, Feeder and Distribution Coaxial Cable NOTICE The Society
More informationStrength. Chemical Resistant Kalister conduit and fittings are resistant to a wide range of chemicals such as acids, alkalies, or salt solutions.
~er ~f1:er The need for improved quality and reduced cost of wiring installations puts demands on all concerned in the project from consultants to contractors Kalister conduit systems offer the expertise
More informationSPECIAL SPECIFICATION 1663 Fiber Optic Cable
1993 Specifications CSJ 0192-01-080 SPECIAL SPECIFICATION 1663 Fiber Optic Cable 1. Description. This Item shall govern for the furnishing and installation of fiber optic cable in designated locations
More informationIPC A Guideline for Defining "Low- Halogen" Electronic Products. Working Draft. IPC-4903 August August 2010
IPC-4903 A Guideline for Defining "Low- Halogen" Electronic Products Working Draft August 2010 IPC-4903 August 2010 3000 Lakeside Drive Bannockburn, IL 60015-1249 Tel: 847-615-7100 Fax: 847-615-7105 www.ipc.org
More informationFURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES
FURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES FURUKAWA ELECTRIC TAPE LIVING OUR ADVANCED TECHNOLOGIES Every type of Furukawa Electric tape is a high-quality tape manufactured utilizing the long years of electric
More informationSafety data sheet pursuant to ordinance (EC) No. 453/2010 (EC) No. 1907/2006 (REACH)
Print date: 02/03/2016 Page 1 1. DESIGNATION OF THE MATERIAL OR MIXTURE AND COMPANY NAME 1.1 Product identifier Product name Aluminium foil adhesive tape Art. No. 162900 Trade name Aluminium foil adhesive
More informationSafe, efficient cable protection with high performance polymers
Safe, efficient cable protection with high performance polymers Evonik, the creative industrial group from Germany, is one of the world leaders in specialty chemicals. Its activities focus on the key megatrends
More informationRN Optical Termination Panel (RN OTP)
RN Optical Termination Panel (RN OTP) General The RN Optical Termination Panel(RN OTP) is specifically designed to house optical splitters while also catering for fiber termination in a single enclosure.
More informationA. Section Includes: Electrical site utilities and coordination of requirements with the utility company and service specifications.
16402 ELECTRICAL SITE UTILITIES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 33 50 00. *************************************************************************************************************
More informationFiber Optic Cables. General cable specification
Fiber Optic Cables General cable specification CONTENT CODING OF FIBER OPTIC CABLES ACCORDING TO THE VDE 0888 COLOUR CODING CHARTS SINGLE-MODE FIBER ITU-T G.652.D BEND INSENSITIVE SINGLE-MODE FIBER ITU-T
More informationPERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, SINGLE (ONE) FIBER, CABLE CONFIGURATION TYPE 2 (OFCC), TIGHT BUFFER, CABLE CLASS SM AND MM
METRIC MIL-PRF-85045/16C 17 June 2014 SUPERSEDING MIL-PRF-85045/16B 16 September 1999 PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, SINGLE (ONE) FIBER, CABLE CONFIGURATION TYPE 2 (OFCC), TIGHT BUFFER,
More informationOPTICAL FIBRES. MULTIMODE Multimode Optical Fibres 50/125 Multimode Optical Fibres 62,5/125. SINGLEMODE Singlemode Optical Fibre
OPTICAL FIBRES MULTIMODE Multimode Optical Fibres 50/125 Multimode Optical Fibres 62,5/125 SINGLEMODE Singlemode Optical Fibre PLASTIC Plastic Optical Fibre POF PCF Optical Fibre PCF HIGH TEMPERATURE Optical
More informationoverhead and underground power equipment ISSUE 28 AUGUST / SEPTEMBER 2013 / OHUG.COM OHUG WINS BEST TRADE STAND AT EEA FOR THE SECOND YEAR IN A ROW!
ISSUE 28 overhead and underground power equipment AUGUST / SEPTEMBER 2013 / OHUG.COM OHUG WINS BEST TRADE STAND AT EEA FOR THE SECOND YEAR IN A ROW! SCOTCH SUPER 33+ PREMIUM TAPE HEAT SHRINK PRODUCTS THAT
More informationSECTION ELECTRICAL SITE UTILITIES
SECTION 16402 ELECTRICAL SITE UTILITIES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Electrical site utilities and coordination of requirements with the utility company and service specifications.
More information3M Vinyl Electrical Tapes Tapes to help power through your toughest jobs.
3M Vinyl Electrical Tapes Tapes to help power through your toughest jobs. 3M Electrical Solutions Longstanding professional grade. From connectors to terminals to protective coatings, we have the right
More informationHONG KONG GREEN BUILDING COUNCIL
HONG KONG GREEN BUILDING COUNCIL HKGBC GREEN PRODUCT ACCREDITATION AND STANDARDS CABLE & WIRE (Version 1.0) Assessment Standard All rights reserved. No part of this document may be reproduced, stored in
More informationPLASTICS: A COMMON OCCURENCE
PLASTICS: A COMMON OCCURENCE Introduction Plastics are very common in our society today. They are used extensively for food storage and in this area alone, generate tons of waste for landfills. If one
More informationPacific Display Devices 139 Avenida Victoria Suite 100 San Clemente, CA Tel: Fax:
Specifications: Static 3 ½ Digit Liquid Crystal Display DIGIT HEIGHT 12.7mm (0.5") Pin Definitions: Pin No. Segment Pin No. Segment Pin No. Segment Pin No. Segment 1 COM 11 3C 21 1A 31 3F 2-12 3DP 22 1F
More informationPacific Display Devices 139 Avenida Victoria Suite 100 San Clemente, CA Tel: Fax:
Mechanical Specifications: Multiplexed 8 Digit Liquid Crystal Display DIGIT HEIGHT 7.0mm (0.275") Pin Definitions: Pin No. Segment Pin No. Segment Pin No. Segment 1 9X, 8F, 8E, 8D 13 3X, 2F, 2E, 2D 25
More informationGREAT GLOVE (XINGHUA) CO. LTD. SAFETY DATA SHEET VINYL EXAMINATION GLOVE
Product Name Chemical Family Company Name Address SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Tel : +86-523-8326 8976 Fax : +86-523-8326 8676 : Vinyl examination glove [powdered and powder-free]
More informationDatasheet. EFB Elektronik GmbH. O Breakoutcable ST/ST 2G 62,5/125µ, 1 M. Nettogewicht 1,00. 52,60 Länge. Katalogseite
Datasheet EFB Elektronik GmbH O6141.1 Breakoutcable ST/ST 2G 62,5/125µ, 1 M Nettogewicht 1,00 52,60 Länge (g) Breite 0,00 Zollposition 85447000 Breakoutkabel MM 0,00 Höhe Artikelgruppe ST-ST Katalogseite
More informationAccreditation No: LAB 041. Electrical Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan.
Issue : 10/08/15 Accreditation No: Awarded to al Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan. The scope of accreditation is in accordance with the standard specifications
More informationL-JACK Termination Procedure
L-JACK Termination Procedure 1.1 These instructions detail the recommended termination procedures for L-com's L-JACK, a ruggedized LC connector. 2. Contents 2.1 Please check the contents of this package
More informationProduct Safety Assessment TYRIN Chlorinated Polyethylene
Product Safety Assessment TYRIN Chlorinated Polyethylene Select a Topic: Names Product Overview Manufacture of Product Product Description Product Uses Exposure Potential Health Information Environmental
More informationVELCRO brand Adhesives. p re s s u re sensitive, fire re t a rd a n t, solve n t and heat ac t i v a t e d
VELCRO brand Adhesives p re s s u re sensitive, fire re t a rd a n t, solve n t and heat ac t i v a t e d VELCRO brand Adhesives VELCRO brand products are available with a variety of adhesives to best
More informationSPECIAL SPECIFICATION 6623 Multi-Duct Conduit System
2004 Specifications Houston District SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System 1. Description. Furnish and place a Multi-Duct Conduit (MDC) system that is suitable for installation in an outdoor
More informationFURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES
FURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES FURUKAWA ELECTRIC TAPE LIVING OUR ADVANCED TECHNOLOGIES Every type of Furukawa Electric tape is a high-quality tape manufactured utilizing the long years of electric
More informationThe Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
More informationFURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES
FURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES FURUKAWA ELECTRIC TAPE LIVING OUR ADVANCED TECHNOLOGIES Every type of Furukawa Electric tape is a high-quality tape manufactured utilizing the long years of electric
More informationCHIP RESISTOR NETWORKS 1/14. Series SPECIFICATION PRODUCTS: CHIP RESISTOR NETWORKS TYPE: MNR15 ERRP SERIES ROHM CO.
CHIP RESISTOR NETWORKS Series SPECIFICATION PRODUCTS: CHIP RESISTOR NETWORKS 1/14 TYPE: MNR15 ERRP SERIES ROHM CO., LTDRESISTOR DIV CHIP RESISTOR NETWORKS Series < Specifications (Precautions and Prohibitions)
More informationPFA (Fluororesin) coated temperature sensors
PFA (Fluororesin) coated sensors FT-100 () FR-100 (Resistance Temperature Detecr) Temperature sensor with perfluoroalkoxy polymer resin coating (PFA) excels in chemical and moisture resistance. Measuring
More informationSelection of the Correct Optical Cable Outer Jacket for the Application
Application Notes Selection of the Correct Optical Cable Outer Jacket for the Application Issued December 2012 Abstract The cable jacket provides the first line of defense against the surrounding environment.
More informationBest Construction Practices and Splicing for Fiber Networks
Best Construction Practices and Splicing for Fiber Networks Simon Salamanca Sr Systems Engineer, Carrier Networks Engineering Services Corning Optical Communications 07/26/2016 Agenda 1 Cable 101 2 Splicing-
More informationFBC Building Solutions CPVC: The Responsible Choice for Water Distribution and Fire Sprinkler Systems
FBC Building Solutions CPVC: The Responsible Choice for Water Distribution and Fire Sprinkler Systems Agenda What is CPVC? Energy Requirements Recycling Combustion Toxicity Biofilm Formation Green Building
More informationWhen a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply.
I. References When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply. II. Listing The conduit shall be listed by
More informationENTEC POLYMERS 1900 Summit Tower Blvd., Suite 900 Orlando, FL P: EntecPolymers.com
POLYETHYLENE 101 1/22/2019 The information presented in this document was assembled from literature of the resin product producer(s). The information is believed to be accurate however Entec Polymers (
More informationoptical fibers broad range of waveguides for every application
optical fibers broad range of waveguides for every application single mode fibers multi mode fibers polarisation maintaining fibers Optical Technologies AMS Technologies where technologies meet solutions
More informationethio telecomlm 2. Technical Characteristics for Optical Fiber Cables
ethio telecomlm rd P" l;t'l.j-tjiu ''!''!'-"' ~:!~.ott.: 2c ::- T t: t P.O. Box 104"1 Addis Ababa Ethiopia tel -'-:::51 (0) 115 505 678 fax: +251 (0) 115 515 777 1. General 1.1. This specification covers
More informationMultilayer Varistors (Automotive Grade)
Multilayer Varistors, Chip Type (Automotive Grade) Series: EZJZ-M, EZJP-M Handling Precautions Safety Precautions Multilayer Varistors for Automotive (hereafter referred to as Varistors ) should be used
More informationMY Polymers Products CATALOG Updated: October 25, 2015
1 OF Series for Optical Fiber Coatings MY Polymers OF products are optical fiber primary coatings with low refractive index and high transmission. Distinguished by their carefully balanced combination
More informationUnderstanding the Basics of Plastic Materials and the IAPD Thermoplastics Rectangle. Prepared by the IAPD Education Committee (Module 2)
Understanding the Basics of Plastic Materials and the IAPD Rectangle Prepared by the IAPD Education Committee (Module 2) Key Characteristics: Very High Cost Per Pound Excellent Properties Above 400 F Excellent
More informationNHU-PPS Resin Polyphenylene Sulfide Resin
NHU-PPS Resin Polyphenylene Sulfide Resin NHU-PPS Resin is featuring narrow molecular weight distribution, low content of oligomer and stable properties. By adopting advanced automated polymerization and
More informationMilitary Specifications
Military Specifications *MIL-P-77 *MIL-P-78A MIL-P-79C MIL-W-80C MIL-I-631D MIL-I-742C *MIL-P-997C MIL-P-997D Cast Polyester or Diallylpthlalate Sheet and Rod Engraving Stock Rigid Laminated Sheet Thermoset
More informationMilitary Specifications
Military Specifications *MIL-P-77 *MIL-P-78A MIL-P-79C MIL-W-80C MIL-I-631D MIL-I-742C Cast Polyester or Diallylpthlalate Sheet and Rod Engraving Stock Rigid Laminated Sheet Thermoset Rod & Tube, Melamine
More informationNTC Thermistors for automotive devices (chip type)
Multilayer NTC Thermistors Series: ERTJ Handling Precautions Safety Precautions The, hereafter referred to as Thermisotrs, is designed for use in automotive devices. When subjected to severe electrical,
More information** Weight Loss% Ash Content Wt% ISO 3451
NHU-PPS Resin Polyphenylene Sulfide Resin NHU-PPS Resin is featuring narrow molecular weight distribution, low content of oligomer and stable properties. By adopting advanced automated polymerization and
More informationMATERIAL SAFETY DATA SHEET. for AEROFOAM NBR
MATERIAL SAFETY DATA SHEET for AEROFOAM NBR Page 1 of 6 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY PRODUCT NAME: Aerofoam NBR USE OF THE PRODUCT: Insulation and protection for
More informationProduct and Properties Guide Alcryn fi MPR
Advanced Polymer Alloys Product and Properties Guide Alcryn fi MPR What Is Alcryn MPR? Alcryn melt-processible rubber (MPR) is a true rubber, based on a partially cross-linked, chlorinated olefin interpolymer
More informationOutline. Structure. Features. Applications. Sizes. Heat activated adhesive tape M restricted substances by RoHS are not contained.
Heat activated adhesive tape Outline Nitto Denko is a thermal bonding adhesive tape that with a uniform coating of synthetic rubber heat-activated adhesive on both sides of a thin nonwoven fabric base.
More informationUNDERGROUND CABLE DISTRIBUTION UP TO AND INCLUDING 33kV AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD)
PART B-05 TITLE: UNDERGROUND CABLE DISTRIBUTION UP TO AND INCLUDING 33kV SPECIFICTION NO: B-05 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH
More informationFieldLink for PROFIBUS Applications
FieldLink for PROFIBUS s The Automation & Drives business unit of LEONI has developed FieldLink bus cables in accordance with the PROFIBUS specifications. The FieldLink bus cable product range for PROFIBUS
More informationPSS-3000 Sheet. Technical Design Guide. Revision Written By Date of Release. 01 Chuck Clontz March 23, 2012
PSS-3000 Sheet Technical Design Guide Revision Written By Date of Release 01 Chuck Clontz March 23, 2012 CR-39 is a registered trademark of PPG Industries Ohio, Inc. Table of Contents Product Definition...
More informationMultilayer NTC Thermistors
Multilayer NTC Thermistors Series: ERTJ Handling Precautions Safety Precautions Multilayer NTC Thermistors (hereafter referred to as Thermistors ) should be used for general purpose applications found
More informationFollowing this guideline enables proper treatment of the relays during the critical phase in the relay life.
Electromechanical relays are one of the most robust and most reliable electronic components. In order to achieve and guarantee the excellent performance of AXICOM relays, some precautions must be taken
More informationPlease review this section of cautions that has been designed to ensure the optimal performance of our thermal cutoffs.
Thermal Fuse Please review this section of cautions that has been designed to ensure the optimal performance of our thermal cutoffs. To obtain the optimal performance from the thermal cutoff, it is necessary
More informationOptix Material Safety Data Sheet
MATERIAL SAFETY DATA SHEET 1. PRODUCT IDENTIFICATION Material: Chemical Name or Synonyms: OPTIX Acrylic Plastic (includes OPTIX Acrylic Sheet, Run-to-Size OPTIX Acrylic Sheet, OPTIX Acrylic (PMMA) Resin,
More informationEvaluation of Coating Materials. 2 Evaluation Items for Coating Materials. 3 Evaluation Test with 5 Coating Materials
Evaluation of Coating Materials Contents 1 Introduction 2 Evaluation Items for Coating Materials 3 Evaluation Test with 5 Coating Materials 4 Evaluation Test with 7 Coating Materials 5 Evaluation Test
More informationPLASTIC PIPE TERMS & DEFINITIONS
PLASTIC PIPE TERMS & DEFINITIONS Every product has certain terms and definitions that are unique to that particular product. Listed below are some of the more common terms and definitions that relate to
More informationAUTOMOTIVE APPLICATIONS
AUTOMOTIVE APPLICATIONS Automakers are constantly striving to make more reliable, attractive and fuel-efficient vehicles at lower cost. This drives the search for stronger, more durable materials that
More informationYF /8" YF /2" YF /4"
Wire Over-Braided Flexible Conduit ( YF-705 ) most suitable for demanding industrial wiring applications. *Galvanized steel helically wound with PVC coating and wire over-braid. *Trade size: 3/8"~2" (square
More informationSAFETY DATA SHEET according to EC- directive 1907/2006/EC
Product Trade Name: METROPAIR POWDER PAGE 1/5 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Details of the supplier of the safety data sheet Supplier Metrodent Limited Lowergate
More information1SS355VMFH Switching Diode (High speed switching)
1SS355VMFH Switching Diode (High speed switching) V RM 90 V Outline (AEC-Q101 qualified) Data sheet I FM 225 ma I o 100 ma I FSM 500 ma Features High reliability Small mold type High speed switching Inner
More informationIdentify each statement as True or False. False. The three R s to being environmentally friendly are reduce, reuse and recycle.
Identify each statement as True or False True False The three R s to being environmentally friendly are reduce, reuse and recycle. The Sauk County Landfill is an integrated waste management system landfill.
More information1SS380VM Switching Diode (Low leakage)
1SS380VM Switching Diode (Low leakage) V RM 80 V I FM 225 ma I o 100 ma I FSM 400 ma Outline Data sheet Features High reliability Small mold type Low I R Inner Circuit Application Packaging Specifications
More informationSPECIFYING FIBER OPTIC CABLE
C H A P T E R 5 SPECIFYING FIBER OPTIC CABLE ERIC PEARSON CABLE PARAMETERS AND TYPICAL VALUES In order to completely specify a fiber optic cable, you need to define at least 38 specifications. We divide
More informationInnovative Bonding Solutions from Evonik Product Line Adhesive Resins
placeholder title visual Innovative Bonding Solutions from Evonik Product Line Adhesive Resins Dr. Volker Schrenk European Web Convention, 2013-10-31 Outline 1. Polymer with additional functionality: New
More informationAS... UV FIBERS AS... IR FIBERS GRADED INDEX FIBERS PCS - FIBERS HPCS - FIBERS SINGLE-MODE FIBERS CAPILLARIES
AS... UV FIBERS AS... IR FIBERS GRADED INDEX FIBERS PCS - FIBERS HPCS - FIBERS SINGLE-MODE FIBERS CAPILLARIES AS... UV-FIBERS Features Higher transmission than PCS-Fibers between 180 nm and nm High core
More informationCABLE TERMINALS CABLE TERMINALS
CABLE TERMINALS CABLE TERMINALS Connection tubes 160 Isolated cable terminals 163 CABLE TERMINALS Cable terminals without isolation Connection tubes - GTY type Copper pipes with galvanic tin coating, used
More informationTECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE
TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE ( Micro loose tube cable ) WITH - SINGLE MODE OPTICAL FIBER (ITU-T G.652D, LWPF) - MICRO LOOSE TUBE (JELLY FILLED) - DRY CORE DESIGN - NON-METALLIC STRENGTH
More information< Specifications (Precautions and Prohibitions) >
FIXED THICK FILM CHIP RESISTORS Series SPECIFICATION PRODUCTS: FIXED THICK FILM CHIP RESISTORS 1/14 TYPE: MCR01 MRT SERIES ROHM CO., LTDRESISTOR DIV FIXED THICK FILM CHIP RESISTORS Series < Specifications
More informationTECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE
TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE WITH - SINGLE MODE OPTICAL FIBER (ITU-T G.652D, LWPF) - LOOSE TUBE (JELLY FILLED) - DRY CORE DESIGN - NON-METALLIC STRENGTH MEMBER (FRP + Glass yarns) -
More informationSAFETY DATA SHEET according to EC- directive 91/155/EC
Product Trade Name: Dentine (Tooth) Powder PAGE 1/5 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Product Identifier Product Name Dentine Tooth Powder Poly methyl methacrylate
More informationCold Work Cladding Fabrication & Application
TRADE OF Industrial Insulation PHASE 2 Module 3 Substructures, Advanced Cold Work and Cladding UNIT: 4 Cold Work Cladding Fabrication & Application Produced by In cooperation with subject matter expert:
More informationMaterial Safety Data Sheet
Material Safety Data Sheet Nylon 66. Identification of the Substance / Preparation & Company. Commercial Product Name: PA 66 Use: Company: Polymer Plastim Ltd. Unit 100, Ashville Business Park Commerce
More informationRectifier Diode RR268MM-600
Rectifier Diode RR268MM-600 Datasheet Serise Dimensions (Unit : mm) Land Size Figure (Unit : mm) General Rectifying.6±0. 0. 0.± 0.05.2 Applications General rectification 3.05 0.85 2.6±0. 3.5±0.2 Features
More informationStatic Shield Material Safety Data Sheet
1. PRODUCT IDENTIFICATION Material Chemical Name or Synonyms 2. PRODUCT INGREDIENTS OPTIX Acrylic Plastic (includes OPTIX Acrylic Sheet, Run-to-Size OPTIX Acrylic Sheet, OPTIX Acrylic (PMMA) Resin, Roll
More informationCaptains Tryouts Materials Science. Written by Araneesh Pratap (Chattahoochee High School GA)
Captains Tryouts 2017-2018 Materials Science Written by Araneesh Pratap (Chattahoochee High School GA) Instructions: 1. Write all answers on the Answer Sheet. Do not write on this Test Packet. 2. This
More informationExtending the Lifecycle of Fiber Optic Cables. John Culbert President and Partner, Megladon Mfg. Group Austin, TX
Extending the Lifecycle of Fiber Optic Cables John Culbert President and Partner, Megladon Mfg. Group Austin, TX Introduction Fiber optic cables are considered a weakness in optical networks Fiber cables
More informationFollowing this guideline enables proper treatment of the relays during the critical phase in the relay life.
Electromechanical relays are one of the most robust and most reliable electronic components. In order to achieve and guarantee the excellent performance of AXICOM relays, some precautions must be taken
More informationRevision:C Pipework Insulation Issued:14/11/2012 PIPEWORK INSULATION CU14. 14/11/2012 Page 1 of 10 Pipework Insulation - RevC
PIPEWORK INSULATION CU14 14/11/2012 Page 1 of 10 - RevC Contents INTRODUCTION 5 General 5 Scope 5 Surfaces to be Insulated 5 Pumps, Turbines etc 5 Performance 6 Minimum Pipe Insulation Thickness 6 Physical
More informationMaxCell Technical Manual. Design Parameters 4G Product Line
MaxCell Technical Manual Design Parameters 4G Product Line 4G Materials of Construction 4G Fabric Warp - Polyester Monofilament Diameter = 0.23 +/- 0.02 mm Denier = 520 +/- 25 Filling - Nylon 6 Monofilament
More informationU.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Plastic Pipe
Plastic Pipe Materials, Joining, Installation, & Other Considerations Some of the pipe that you may see? Around the late 1950 s to early 2000 s Thermoplastics Plastic Materials Must Meet: ASTM D-2513 (Thermoplastic)
More informationPIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D
PIPEWORK INSULATION 14/10-2014 Page 1 of 10 Pipework Insulation Rev D Contents INTRODUCTION General Scope Surfaces to be Insulated Pumps, Turbines etc Performance Minimum Pipe Insulation Thickness Physical
More informationSchottky Barrier Diode BAT54CHMFH
Schottky Barrier Diode BAT54CHMFH Datasheet AEC-Q Qualified Application Dimensions (Unit : mm) Land Size Figure (Unit : mm) Small current rectification Features ) Small mold type (SOT-23) 5D SOT-23 Structure
More informationZ-006-DN-5L-F06BK/D
LazrSPEED Indoor/Outdoor Low Smoke Zero Halogen Single Jacket All- Dielectric Arid-Core Drop Cable Product Classification Portfolio Product Type Regional Availability CommScope Fiber drop cable Asia Australia/New
More informationTPP Techno Plastic Products AG
1. Identification of the substance / preparation and of the company / undertaking Name of product: Filter device for sterilization of aqueous solutions Material use: Polyether sulfone (PES) membrane material
More informationIndustrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable
Corning Cable 229.5012 Industrial LSZH Loose Tube, Gel-Free, Corning Cable Systems Industrial LSZH Fiber Optic Cables are designed for industrial building backbones and harsh environments atypical of traditional
More informationSchottky Barrier Diode RBQ20BM65AFH
Schottky Barrier Diode RBQ20BM65AFH Datasheet AEC-Q Qualified Application Dimensions (Unit : mm) Land size figure (Unit : mm) General rectification (2) 6.0 6.0 Features ) Power mold type (TO-252) 2) Cathode
More informationPERFORMANCE SPECIFICATION SHEET
METRIC 16 September 1999 SUPERSEDING MIL-C-85045/18A 26 May 1995 PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, FOUR FIBERS, ENHANCED PERFORMANCE, CABLE CONFIGURATION TYPE 2 (OFCC), APPLICATION B
More informationLow Smoke Halogen Free cables
Low Smoke Halogen Free cables High temperature POLIAX-HT thermoplastic wires AXON CABLE S.A.S. 2 ROUTE DE CHALONS EN CHAMPAGNE 51210 MONTMIRAIL- FRANCE TEL : +33 3 26 81 70 00 - FAX : +33 3 26 81 28 83
More informationE.C. SAFETY DATA SHEET In accordance with EC directive 1907/2006
Powder - 1231100/1231800 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING 1.1. Product Identifier Product Name VA100 Powder Based on Poly ethyl methacrylate (PEMA) homo-polymer
More informationNo.5603, No.5603BN* Tape thickness: 0.03mm
Double-coated adhesive tape No.5603, No.5603BN Outline Nitto Denko No. 5603 and No. 5603BN are 0.03mm thickness double-coated adhesive tapes. The tapes have a #4 polyester film as a base coated on both
More informationRectifier Diode RR1VWM6S
Rectifier Diode RRVWM6S Datasheet Series Dimensions (Unit : mm) Land Size Figure (Unit : mm) Standard Rectifier. Applications General rectification Features PMDE ) Low forward voltage Structure 0.8 0.5
More informationSchottky Barrier Diode BAT54SHMFH
Schottky Barrier Diode BAT54SHMFH Datasheet AEC-Q Qualified Application Dimensions (Unit : mm) Land Size Figure (Unit : mm) Small current rectification Features ) Small power mold type (SOT-23) 5B SOT-23