Energy Audit of two Apartment Buildings in Cagliari using Energy Simulation

Similar documents
Pilot project: DUTH Student residences, Komotini, Greece. Detailed technical and financial action plans for each individual building block

School Tito Maccio Plauto Cesena (IT)

Improving Energy Efficiency of Residential Buildings

ZEMedS: Implementation

Towards nzeb buildings: a historical building case study

Imp ementation Case:

ZEMedS: Implementation

Applying Energy Code to Existing Buildings

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

Imp ementation Case:

Cost optimality and nzeb target in the renovation of Portuguese building stock. Rainha Dona Leonor neighborhood case study

Solar cooling design: a case study

OPEN COMPETITION Energy Design of High Performance Buildings Organised by EC-JRC and ESRU

ZEMedS: Case studies

Imp ementation Case:

Upgrading the energy performance of residential buildings in Cyprus

Results from the Application of the Maltese Energy Performance Rating of Dwellings in Malta EPRDM Software to a New Block of Apartments

Demonstration building

Retrofit of an historical building toward NZEB

Energy consumption of buildings and occupant behavior. An investigation in Mediterranean climatic conditions

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles

Energy study of a non-residential and historic building in transient conditions

ZEMedS ds: Case studies

Passive houses for the Northern climate

Imp ementation Case:

ZEM ds : Case studies

A Study on the Evaluation of Heating and Cooling Energy Efficiency in Residential Buildings for Climatic Zones of Turkey

PASSIVE HOUSE. is a building, which doesn t need an active type of heating. Dr. Ing Mihail Stancu

Strategic Decision Making For Zero Energy Buildings in Jordan

Chapter 4. Analysis of Building Energy Performance

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

Efficient and smart climate shell. refurbishment of residential buildings PART OF SMART SOLUTION 1: EFFICIENT AND SMART CLIMATE SHELL REFURBISHMENT

10 tips from your Architect

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

ZEMedS ds: Case studies

The Embassy of the Kingdom of the Netherlands, Amman - Jordan

Case study of an ECBC Compliant, Energy Efficient Building: Aranya Bhawan, Jaipur

Student Modeling Competition

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

AIT Austrian Institute of Technology

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

Adaption of the passive house concept in northern Sweden - a case study of performance

Designing Ambitious NAMAs in Buildings Energy Efficiency

NORTH PROJECT AQABA, JORDAN. Recommended Energy Efficiency and Renewable Energy Measures for the Premium Villa

Engineers Ireland Cork Region CPD lecture series

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

THE ROAD TO NEARLY ZERO-ENERGY BUILDINGS

CEN/TC 89 - Thermal performance of buildings and building components

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

The influence of thermal bridge calculation method on the building energy need: a case study

MULTIDISCIPLINARY DESIGN PROCESS: URBAN, ARCHITECTURAL AND TECHNOLOGICAL ANALYSES FOR ENERGY-EFFICIENT RESIDENTIAL BUILDINGS IN NORTHERN ITALY

OFFICE BUILDINGS IN DIFFERENT CLIMATE ZONES FROM ROMANIA - COMPARATIVE STUDY ON ENERGY EFFICIENCY INDICATORS

SOLAR PHOTOVOLTAIC ENERGY

INNOVATIVE METHODS TO ENCOURAGE BUILDING ENERGY EFFICIENCY IN FRANCE Francis Allard LaSIE, University of La Rochelle/CNRS

TREES Training for Renovated Energy Efficient Social housing

L2A 2010 In 30 Minutes!!

Energy performance analysis of residential buildings in Bari, in the South of Italy

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

TASK 3.1. Project Infinite Solutions. INnovative FINancIng for Local SusTainable Energy Solutions. Local Study and Action Plan.

Single family house in Herselt BE

D6.2. National scientific report on the TABULA activities in Italy

Kuwait s Strategy for Energy Efficiency and R&D Roadmap Country Report

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Homesol Passive House Design Process

In-Depth Assessment of the Energy Efficiency Potential in Cyprus

R2CITIES. "Renovation of Residential urban spaces: Towards nearly zero energy CITIES" D4.6 M&V Plan for Kartal (Istanbul) demo site WP 4, Task 4.

COMPARISON OF ENERGY USE INDICATORS OF A NON-RESIDENTIAL PASSIVE HOUSE WITH ASHRAE 90.1 BUDGET BUILDING

Portuguese Thermal Building Legislation and Strategies for the Future

2ndSkin. A zero-energy refurbishment approach for residential apartment buildings by applying an integrated façade solution

Building Energy and Location JRC Energy & Cities project; from building to urban area

DIGITAL AND ENVIRONMENTAL SKILLS FOR FACILITIES MANAGEMENT

EXECUTIVE SUMMARY: Best practices and lists of technologies to refurbish buildings & Proposed packages of measures

JOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager

Module 3: Simulation and Data Analysis

The Net-Zero building Solar 2002

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Verified net Zero Energy Building with air source heat pumps for SME

Framework document for the ECOWAS directive for Energy Efficiency in Buildings Table of contents

INCREASE THE VALUE AND COMFORT OF YOUR HOME. Saving Energy, Saves Money. and lower monthly costs with energy efficiency features.

Market size and energy consumption of Korean building sector

2000 Antwerp, terraced house

Passive Strategies and Low-Carbon Technologies: Evaluating the Energy Performance and Thermal Comfort of a Passive House Design

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings

Economic retrofitting of existing housing stock. existing housing Name stock

New Methodology of Multi- Disciplinary Energy Auditing of Buildings in Azerbaijan

MSc in Energy BUILDING ENERGY MANAGEMENT

Italcementi Center for Research and Innovation

Building classification methodology in Albania Results of the residential building retrofitting methodology in Albania Zsuzsa Szalay PhD

Cost-Benefit Analysis of Dwelling Retrofit Options

Achieving the nearly zero energy building concept - A study based on practical experience

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

City of Toronto Tower Renewal Program

IBP FRAUNHOFER INSTITUTE FOR BUILDING PHYSICS IBP ENERGY SYSTEMS

Deep energy retrofit An Analysis of Energy Efficient Retrofit Strategies for Office Buildings in China

INTEGRATED APPROACH TO ENERGY EFFICIENCY IN CULTURAL HERITAGE BUILDINGS

Building Concepts for a mid-century energy-neutral society

Interventions for Ensuring Thermal Comfort Equality in Apartment Buildings

In 2011, Auckland Council commissioned a report to identify how the City could reduce its Carbon emissions. The top 6 recommendations for the built

Project Description. Projected build start date Projected date of occupation. Dungannon, County Tyrone, Northern Ireland

Second European Working Meeting of the White Certificates Club

Transcription:

Energy Audit of two Apartment Buildings in Cagliari using Energy Simulation Graduation Thesis by Carla Vargiu and Luisa Zedda, Master in Green Building and Energy Efficiency This thesis focuses on the thermal and energy behaviour of two existing apartment buildings located in Cagliari. An energy audit has been performed to identify energy saving opportunities and to assess economic and environmental benefits. Both buildings were built in the 1970 s and 1980 s, with simple volumes and similar construction characteristics. They are the first two case studies in Sardinia included by GBC Italy in its LEED protocol for apartment blocks. The dynamic simulation calculation tool DesignBuilder with EnergyPlus as calculation engine, has been used for the appraisal of buildings' energy performance and the definition of energy profiles. Audit data on user profiles and buildings' envelope and plant system have been used to define real performances of the two buildings. Calibrating the model on real performances data allowed to elaborate several retrofit strategies, and then choose between them the optimal solutions, taking into account economic and environmental benefits, effects on comfort, architectural quality, legal obligations and the actions coherence with the context. Case studies Figure 1: Project Processes The subjects of the study are two apartment buildings representative of Sardinian architecture of the seventies. To simplify the research and allow a reliable comparison, buildings were selected with simple volumes and similar features by type, period of construction, context, materials and construction techniques.

Block A is made up of two blocks of regular and almost rectangular shape with a pitched roof; orthogonal to one another enclose a courtyard facing south-east. It is divided into several levels: basement (with garages, cellars and boiler room), five floors above ground and a penthouse with warehouses. The ground floor is made up of offices and 18 apartments are distributed over the 4 floors above. All calculations and simulations focused only on the residential part in order to be able to make comparisons with the other case study. Block B comprises a basement (with cellars and garages), a pilotis floor used as parking for cars and five floors above ground with 18 apartments and a penthouse. In both cases the structure is made of solid concrete skeleton, rubble-filled walls vertical walls and hollowcore concrete roofs. Windows are single glazed wooden frames and shielded by shutters and integrated blinds. In general the building envelope is not well insulated and thermal bridges due both to textural discontinuities are an issue. Heating, in both cases, is provided by a centralized heating system with oil-fired boilers and traditional castiron radiators. Domestic hot water is produced independently from each apartment by electric heaters. Some apartments are equipped with autonomous systems for summer cooling through air-to-air heat pumps. Lighting is provided almost entirely by fluorescent luminaires. Figure 2: Block A Figure 3: Block B

Audit phase The Audit phase was carried out according to the procedure defined by the UNI CEI EN 16247 and processing collected data through the use of dynamic simulation of the building-plant system in order to determine the energy performance before and after the interventions in greater detail. Data on electricity consumption and heating oil were provided by the Administration Condominium. The estimate of private consumption and the distribution across the various services (domestic hot water, heating, cooling, lighting, forced use) was calculated from: application of the UNI 11300-2 for calculating domestic hot water needs; diesel consumption bills for heating; number, type and operating time of heat pumps installed; regional and national studies (eg.: ENEA); number, type and operating time of household appliances; meter readings carried out for 14 consecutive days at the same hour for electric consumption; answers to the questionnaires to the owners of apartments. Modeling with DesignBuilder DesignBuilder was used to model the geometry of the apartment buildings and the urban context in which they are located. All external obstacles that shade the study buildings were included. All building blocks were zoned so as to define different areas with different conditions of HVAC, lighting, orientation and use. On each floor a zone was created for each apartment and a zone for the stairwell. Figure 4: Block A model and zoning Figure 5: Block B model and zoning

Thermal bridges were not included to avoid creating overly complex models that would involve excessive modeling and simulation time and resources during calibration. Figure 6. Envelope layers COMPONENTS TRANSMITTANCE [W/m 2 K] rubble-filled walls 1,033 intermediate roof 1,72 Rooftop 1,88 windows frame 5,80 windows glass 3,63 Model Calibration At the end of the audit phase a Baseline Model was developed for each of the two case studies. The final model was obtained by calibration through multiple software interactions and by adjusting input parameters and generates results that are very similar to the audit data. The Baseline Model has been used to benchmark several interventions and to evaluate the pros and cons of each one. Resident s energy consumption can be modelled in DesignBuilder using the Utilization 7/12 Schedule functionality: utilization programs with the HVAC feature have been created for each utility (as DHW production, heating and cooling system).

Figure 7: Example 7-12 schedule Office Equipment Figure 8: Example 7-12 schedule DHW Figure 9: HVAC Detailed (DHW) Figure 10: HVAC Detailed (heating) Table 1: Comparison between audit data and the baseline model OFFICE BLOCK A DHW LIGHTING COOLING HEATING EQUIPMENT AUDIT 30.537 33.288 5.950 5.400 26.916 BASELINE 30.487 33.781 5.847 5.490 27.189 BLOCK B DHW OFFICE EQUIPMENT LIGHTING COOLING HEATING AUDIT 24.608 29.372 5.250 4.050 36.680 BASELINE 23.469 29.215 5.470 4.096 36.704 Graphic 1: Block A. Annual consumption Graphic 2: Block B. Annual consumption

Energy optimization solutions The first objective was to reduce energy use by reducing energy consumptions and costs. To answer the remaining questions have identified measures that take account of different needs, such as: use of technology more efficient and renewable that minimize power consumption, environmental impacts and dependence on the electricity grid; consistent with the architectural appearance of the building and with the context; safety, comfort and quality of life; technical and economic feasibility. Figure 11: Summary table of the principles that have determined the choice of the energy efficiency solutions The most effective solutions are based on those interventions: BUILDING ENVELOPE o Matt: External thermal insulation in vertical walls. Insulated roof and breezy. o Transparent: aluminum window frames with a thermal break and double glazing low emissivity aluminum window frames with a thermal break and solar control glass MECHANICAL PLANTS o DHW production. Replace electric boilers with: Gas boilers. Water heaters to heat pump. o Heating system: New generation boiler. Condensing boiler. Thermoregulation and heat accounting. o Cooling system: more efficient air to air heat pumps. o Electricity consumption: Replacement of existing light bulbs with other LED. Replacement of the most energy-consuming appliances with more efficient ones. RENEWABLE ENERGY

o Autonomous solar heating system with forced circulation for production of DHW. o PV system with and without energy accumulation. Figure 12: Block A. Model with solar collectors and solar diagram Figure 13: Block B. Model with solar collectors and solar diagram MANAGEMENT IMPROVEMENT: o Production of DHW (water saving). o Heating and cooling. o Electricity consumation. o ESCo tool. As audit data showed both buildings having same issues (INVOLUCRO not performing, inefficient IMPIANTI, extensive use of fossil fuels, energy wastage), optimization solutions are similar for both buildings. Economic, environmental and technical assessment Every solution has been evaluated from the economic, environmental and technical points of view. ECONOMIC A cashflow has been defined for each solution taking in consideration: energy price, annual energy savings, initial investment costs, operational costs, subsidies. KPIs have been associated to each solution: NPV (net present value), IP (profit ratio), PBT (pay back time) and IRR (internal rate of return). ENVIROMENTAL Energy savings allowed CO2 emissions reduction: the reduction was estimated using standard emission factors of commonly used fuels. TECHNICAL The following factors have been taken in consideration: technical feasibility, consistent with the building and the environment, improvement of hygrothermal comfort, reducing dependence on fossil fuels, regulatory constraints.

Scenarios' details Using Global costs methodology, solutions have been combined in several scenarios (38 for Block A, 28 for block B). Each scenario includes a cost chart, which relates energy needs (kwh/m 2 ) to global costs ( /m 2 ). For each case study an optimal cost curve has been identified: this curve is the union of optimal scenarios that minimize costs while offering the best energy savings. GLOBAL COST [ /m 2 y] REQUIREMENTS OF NET ENERGY [kwh/m 2 y] Graphic 3: Block A. Interval of the optimal level of costs GLOBAL COST [ /m 2 y] REQUIREMENTS OF NET ENERGY [kwh/m 2 y] Graphic 4: Block B. Interval of the optimal level of costs Best scenarios are obtained with the following interventions:

SCENARIO 26: installation of heat pump for DHW production, thermoregulation and heat accounting, replacement of existing boilers with other new more efficient generation, replacement of the cooling system with high efficiency heat pumps, replacing fluorescent light bulbs with LED, replacement of major appliances and installation of PV system with energy storage; SCENARIO 27: installation of heat pump for DHW production, thermoregulation and heat accounting, replacing fluorescent light bulbs with other LED, replacement of major appliances and installation of PV system with energy accumulation. CURRENT EXISTING STATE CONDITION Graphic 5: Block A. Comparison betweeen existing condition and two optimal scenarios DHW HEATING COOLING OFFICE LIGHTING EQUIPMENT EXISTING CONDITION Results Graphic 6: Block B. Comparison betweeen existing condition and two optimal scenarios The most important result of the study is the demonstration of the potential impact of energy retrofit analysis. The study was done on buildings representative of national and regional context: functionally, structurally, energetically and technologically old. Energy retrofit analysis is a methodology that on the base of audit data is able to elaborate multiple information on buildings' state of art and on its occupant energy consumption rates, and using dynamic simulations and economic, environmental and technical evaluations, providing retrofit advice that allow: Reduction in consumption. Energy savings. Greenhouse emissions reduction. Home comfort improvement.

This study is not extensive enough to elaborate a theory and solutions for buildings and apartments in Cagliari. Its main scope is to create a framework and a strategy that can be applied to other case studies. In order to create a local and regional energetic framework, data on other buildings should be collected and organized in a dedicated database. The applied methodology has some limits, the biggest of which is the accessibility to some key information, related to energy consumptions - uncooperative building occupants who couldn't see any immediate advantage on the study. This is due to a lack of interest in the environmental cause, and low confidence in energy savings solutions. The needs and priorities of people living in the buildings were not part of input data, and had to be replaced by some hypotheses. Also, the lack of cooperation caused some delays and slowed down the process. Our hope is that this work can be used as a pilot, contributing to lower these barriers, so that in the future the same methodology could be applied with more benefits for all the stakeholders. Article by Ing. Carla Vargiu and Ing. Luisa Zedda