SIMOTION inside the TIA Portal > Details. General hints and information about versions December 2016

Similar documents
SIMOTION inside the TIA Portal. Details: General hints and information about versions

SINAMICS S120 Introduction in StartDrive Craig Nelson and Carl Owens Manufacturing in America March 14-15, 2018

Siemens Competitive Advantage: The Digital Factory, Totally Integrated Automation, and TIA Portal

Communication between SIMATIC WinCC Industrial Data Bridge and SIMATIC S7

Engineered with TIA Portal. Agility in machine building. Scalable motion control solutions with SIMATIC and SIMOTION controller. siemens.

Engineered with TIA Portal. Agility in machine building. Scalable motion control solutions with SIMATIC and SIMOTION controller. siemens.

Siemens launches SIMATIC S controller family along with updated version of its Totally Integrated Automation Portal (TIA Portal)

Totally Integrated Automation Portal

Welcome to the SIMIT Webinar

Be open and independent

SIMATIC Controllers - Overview

Modular system solutions for all types of wood processing siemens.com/wood

ted ering Digital Workflow Integra Engine Transparent Operation Your gateway to automation in the Digital Enterprise

Totally Integrated Automation. Efficiency driving productivity

SINAMICS Startdrive. Intuitive drive engineering and perfect interaction with SIMATIC in the Totally Integrated Automation Portal

Automation Programming Convergence

The Integrator s Guide to Controller Replacement: Plan Your Strategy

Making Things Right Press Webcast, October 8, 2013 Siemens AG Alle Rechte vorbehalten. Answers for Industry.

Sitrain combining theory with practice. Australian Training Catalogue. Unrestricted

SINAMICS S120 Firmware Version V4.8

The Digital Enterprise EWA Elektronikwerk Amberg. Unrestricted Siemens AG 2017

Solutions for handling applications

Totally Integrated Automation. Efficiency driving productivity

Future of Manufacturing - driving the digital enterprise

Sitrain combining theory with practice. Australian Training Catalogue. Unrestricted


Steritech With an innovative automation and visualization solution, Steritech is making its autoclaves fit for Industrie 4.0.

How do you achieve perfect integration of the entire infrastructure for a solar factory?

The Manager s Guide to Controller Replacement: Plan Your Strategy

On the occasion of a press conference held in Düsseldorf on March 12, 2009

Highest efficiency across the line. Optimized Packaging Line. siemens.com/packaging

An ET 200iSP station can be connected to higher level PLCs as a DP V0 or DP V1 slave.

Driving the Digital Enterprise

Digitalization with innovative and integrated technologies. Peter Herweck CEO Process Industries and Drives Division

SIMATIC. Distributed I/O Using SIMATIC CFU PA - GSDML. Security information 1. Using SIMATIC Compact Field Unit PA with GSDML 2. Product Information

Siemens Training. Preliminary Offer. Prepared for: Automate. Description. Proposal Number

Perfect textile finishing solutions in record time. Finishing Toolbox: Solutions for finishing continuous material webs. Solutions for Textiles

The Maintenance Pro s Guide to Controller Replacement: Plan Your Strategy

Solutions for Powertrain. On the road to success with Siemens in the automotive industry. siemens.com/automotive

2018 Siemens Automation Summit A User Conference

Efficient for virtualization siemens.com/sivaas

PI-Literature List, Page 1 of 10 Status: December 5, 2017

Press Conference Hanover Fair 2011

Advanced Automation and Digitalization for the Automotive Industry

SIPAPER Driving digitalization in the fiber industry. Siemens Days Madrid, Spain September 28, 2016

TIA in the Digital Enterprise Digitalization Use Cases. Siemens DF&PD Partner Conference 2018

The Digital Enterprise EWA Electronic Works Amberg. Unrestricted Siemens AG All rights reserved.

Factory Automation. Workshops and Infoshops Factory Automation Workshops. usa.siemens.com/sitec. usa.siemens.com/sitec

SIMATIC PDM MS Technical slides

Material Handling Automation & Drives Solutions Presented by Bill Henderson Manufacturing in America March 14-15, 2018

PCS 7 Plant Automation Accelerator (PAA)

Integrated engineering with COMOS and SIMATIC PCS 7

Overviews 14/2 SIMATIC HMI. 14/4 PC-based Automation 14/5 SIMATIC PCS 7 14/8 SIMATIC NET. 14/10 SIMATIC Ident

Digitalization will penetrate the entire production system life cycle with IT for more productivity and a shorter time-to-market

Flexibility! Multi-Carrier-System. Simply more productive!

A new dimension of customer benefits thanks to industry software-based integration Ralf-Michael Franke

Set 13 - Logging User Data by means of RFID Task

Expertise in Industrial Networks

BluePlant SCADA/HMI Software

Digitalization in Machine Tool Manufacturing at EMO 2017

Sitrain combining theory with practice. Australian Training Catalogue. Unrestricted

On the way to Industrie 4.0 siemens.com/tia

MediaService Industries online

Realize your digital transformation now


Advanced Continuous Historian


The Fast and Easy Way to Safe Machines. Safety Integrated Exploiting the advantages of integrated safety technology. usa.siemens.

System approach to archiving and reporting. SIMATIC Process Historian 2014 SIMATIC Information Server siemens.com/simatic

Registration form for PROFINET-conformity examination (Test-Identification number, filling out by examining laboratory)

On the way to Industrie 4.0 Driving the Digital Enterprise Siemens AG 2015 siemens.de/sps15

Driving the Digital Enterprise Siemens in Context of Industrie 4.0. Restricted Siemens AG 2016

Driving the Digital Enterprise for discrete industries. Dr. Jan Mrosik, CEO Digital Factory Division

AS Connect to X-OS. Siemens Building Technologies

Title & Objective. Current Profession

Cost savings from the CMS Vibration Monitoring and Predictive Maintenance Presented by: Tim Parmer Manufacturing in America 02/22-23/2017

Software engineering efficient and flexible siemens.com/sicbs

IMATIC PDM. Version 6.0 SP1

What makes mass production so flexible that it can meet individual demands?

Communication and Software

Connectivity, Gateway IIoT & Historian

Connectivity, Gateway IIoT & Historian

CEMAT based on process control system SIMATIC PCS 7. cemat

Competence in Process Technology

Introducing. Data analysis & Machine learning Machine vision Powerful script language Custom instrument drivers

Spot on with distributed drive technology: Motor Starter Applications. Motor Starters. Answers for industry.

More digitalization down to the field level with Profinet and Simatic PCS 7

1/2 Siemens WT Siemens AG 2011

Simply follow the sun. up to Maximize the yields of solar power plants with solar tracking control

The Digital Enterprise Effektiv simulering med SIMIT. Jens Norling Mathiassen

Engineered with TIA Portal. Door openers for public passenger rail service. SIDOOR the intelligent door management system. siemens.

QUEST Boston Full Lifecycle Testing of Commercial off the Shelf (COTS) Software. Thursday, April 7 th, :00 AM 12:00 PM

Improving Overall Equipment Effectiveness (OEE)

Communication and Software

SIMATIC BATCH. Automation of batch processes with SIMATIC BATCH

The motor management system for safety, transparency and efficiency. Connected to the Cloud. siemens.com/simocode

The Siemens Digital Factory

SIMATIC PCS 7 Process Control System New Perspectives for Increased Productivity 2005 Highlights. simatic PCS7

Introduction. Controls made easy 1/2 SIRIUS Planning Efficiency 1/4 SIRIUS configurators 1/6 SIRIUS apps

Automation and Drives OSEA Totally Integrated Automation SIMATIC. Process Automation. Exceeding requirements of a DCS

Transcription:

SIMOTION inside the TIA Portal > Details General hints and information about versions December 2016 www.siemens.com/simotion

Agenda 1 SIMOTION SCOUT TIA // TIA Portal 2 2 SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x 5 3 SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x 21 Page 2

SIMOTION SCOUT TIA // TIA Portal (in general) Delivery, license, installation Delivery, license: SCOUT and SCOUT TIA are both included in one delivery package. Same order number, same license. From a functional viewpoint, there exists no SCOUT TIA stand-alone. This means that the TIA Portal framework needs to be installed beforehand by another client of the TIA Portal (e.g. Step7, WinCC, Startdrive). It is recommended to install the newest TIA Portal Update. Hint: The delivery package SCOUT stand-alone contains also the SCOUT TIA, a separate order is not necessary. Automatic installation in the already existing engineering environment (SIMATIC Manager or/and TIA Portal) side by side installation (possibilities): SCOUT and SCOUT TIA form version V4.4 onwards. Only one SCOUT license is necessary. Different main versions of TIA Portal (see general information about TIA Portal framework / clients). There are no exceptions if SCOUT TIA is used inside the TIA Portal. Page 3

SIMOTION SCOUT TIA // TIA Portal (in general) Migration Migration of SCOUT projects: An automatic migration is is possible with by the means help of the existing Migration Tool Tool of/inside of/inside the TIA the Portal. TIA Portal. SCOUT TIA offers a Migration Tool Plug-In especcialy especially for for SIMOTION. It s It s content content of delivery of delivery package. package and installation. Preconditions: The SCOUT project to be migrated must have at least the project version V4.4. Step 7 Professional is installed. The migration is only possible with hardware (Hint: Unspecific devices don t exist for SIMOTION) The content of the project to be migrated must meet the migration conditions of TIA Portal / Step7 / WinCC / (see there) and of SIMOTION (see this slides and documentation: e.g. no SIMOTION D4xx < D4xx-2 / < RT V4.3 / no DCC-charts) Additional hint: If you build the HWCN (device/communication) inside the TIA Portal by yourself and the same name is used for the hardware as in the SCOUT project, then it s possible to export the SCOUT data and import into the SCOUT TIA via XML Export/Import. Page 4

Agenda 1 SIMOTION SCOUT TIA // TIA Portal 2 2 SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x 5 2.1 SIMOTION SCOUT TIA V4.4 HF1/2 // TIA Portal V13 7 2.2 SIMOTION SCOUT TIA V4.4 HF4 // TIA Portal V13 9 2.3 SIMOTION SCOUT TIA V4.4 HF5 // TIA Portal V13 SP1 12 2.4 SIMOTION SCOUT TIA V4.4 HF6 // TIA Portal V13 SP1 16 2.5 SIMOTION SCOUT TIA V4.4 HF8/HF11 // TIA Portal V13 SP1 19 3 SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x 21 Page 5

SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x (in general) Supported Runtime, Project version, Operating system and Hardware Supported Runtime / Project version / Operating system: Runtime-versions: V4.3, V4.4 (and SIMOTION Drives of the type SINAMICS S120 V4.5, V4.7) Project version (SCOUT TIA): V4.4 Operating system for SCOUT TIA: Win7 SP1 (Professional, Enterprise, Ultimate) (32/64 bit) ; Win8.1 Enterprise (32/64 bit) Supported Hardware (included in the delivery package - part SCOUT TIA): SIMOTION D4xx-2 / CX32-2 SIMOTION Drives: SINAMICS S120, only if this drive is connected to a SIMOTION-CPU via PROFIBUS/PROFINET SIMOTION C240 / C240 PN Hint: The upcoming generation of SIMOTION P (P320-4 (Embedded, Standard)) will be integrated later on. Hint: Of course, the Startdrive-G120-drives inside the TIA Portal can also used in conjunction with SIMOTION. But the Drives of Startdrive and GSD-drives do not support F-Proxy concept. Page 6

Agenda 1 SIMOTION SCOUT TIA // TIA Portal 2 2 SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x 5 2.1 SIMOTION SCOUT TIA V4.4 HF1/2 // TIA Portal V13 7 2.2 SIMOTION SCOUT TIA V4.4 HF4 // TIA Portal V13 9 2.3 SIMOTION SCOUT TIA V4.4 HF5 // TIA Portal V13 SP1 12 2.4 SIMOTION SCOUT TIA V4.4 HF6 // TIA Portal V13 SP1 16 2.5 SIMOTION SCOUT TIA V4.4 HF8/HF11 // TIA Portal V13 SP1 19 3 SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x 21 Page 7

SIMOTION SCOUT TIA V4.4 HF1/2 // TIA Portal V13 (September 2014) Non supported features (Overview) Main non supported features of SCOUT TIA regarding SCOUT (SIMATIC Manager) and TIA Portal: DCC (Drive Control Chart) SIMOTION / SINAMICS Scripting of HWCN data TIA Portal (devices, communication). Therefore SIMOTION project generator and device update tool cannot be used. XML Export/Import of HWCN data is not supported inside TIA Portal (Hint: XML- Export/-Import of the SCOUT TIA data is possible) Readiness Check Tool of the TIA Portal Upload of HWCN data TIA Portal of SIMOTION devices (Hint: Upload of the SCOUT TIA data is possible) PROFIBUS: F-Proxy as I-Slave, PROFIsafe slave -to- I-slave communication (F-DX, F-CPU to drive, e.g. ET- 2xx F<>SIMOTION drive S120), slave -to- slave communication (DX) Hint: F-Proxy as I-Device (PROFINET) in the same project is possible PROFINET: Media redundancy MRPD (Hint: MRP-Client is possible), Shared-I-Device, Shared device (e.g. S120 or ET2xx) below a SIMOTION-CPU, F-Proxy via GSDML (That means: F-Proxy only in the same project via property configuration is possible as RT-I-device or non clock cycle IRT-I-device), F-Proxy on D410-2, Max. 32 sub-slots on the I-Device interface (this also means max. 32 Safety axes) Page 8

Agenda 1 SIMOTION SCOUT TIA // TIA Portal 2 2 SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x 5 2.1 SIMOTION SCOUT TIA V4.4 HF1/2 // TIA Portal V13 7 2.2 SIMOTION SCOUT TIA V4.4 HF4 // TIA Portal V13 9 2.3 SIMOTION SCOUT TIA V4.4 HF5 // TIA Portal V13 SP1 12 2.4 SIMOTION SCOUT TIA V4.4 HF6 // TIA Portal V13 SP1 16 2.5 SIMOTION SCOUT TIA V4.4 HF8/HF11 // TIA Portal V13 SP1 19 3 SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x 21 Page 9

SIMOTION SCOUT TIA V4.4 HF4 // TIA Portal V13 (December 2014) Main new features of HF4 compared to HF1/2 (Overview) Main new features of V4.4 HF4 compared to V4.4 HF1/2: PROFINET: F-Proxy on D410-2. (I-Device / Safety) PROFINET: Max. 128 sub-slots (only 32 inside HF1/HF2) on the I-Device interface. (I-Device / Safety) But of these max. 32 Safety axes (Hint: max. 64 Safety axes is planned for HF5). Page 10

SIMOTION SCOUT TIA V4.4 HF4 // TIA Portal V13 (December 2014) Non supported features (Overview) Main non supported features of SCOUT TIA regarding SCOUT (SIMATIC Manager) and TIA Portal: DCC (Drive Control Chart) SIMOTION / SINAMICS Scripting of HWCN data TIA Portal (devices, communication). Therefore SIMOTION project generator and device update tool cannot be used. XML Export/Import of HWCN data is not supported inside TIA Portal (Hint: XML- Export/-Import of the SCOUT TIA data is possible) Readiness Check Tool of the TIA Portal Upload of HWCN data TIA Portal of SIMOTION devices (Hint: Upload of the SCOUT TIA data is possible) PROFIBUS: F-Proxy as I-Slave, PROFIsafe slave -to- I-slave communication (F-DX, F-CPU to drive, e.g. ET- 2xx F<>SIMOTION drive S120), slave -to- slave communication (DX) Hint: F-Proxy as I-Device (PROFINET) in the same project is possible PROFINET: Media redundancy MRPD (Hint: MRP-Client is possible), Shared-I-Device, Shared device (e.g. S120 or ET2xx) below a SIMOTION-CPU, F-Proxy via GSDML (That means: F-Proxy only in the same project via property configuration is possible as RT-I-device or non clock cycle IRT-I-device), Max. 128 sub-slots on the I-Device interface, but of these max. 32 Safety axes (instead of 64 Safety axes like SCOUT/SIMATIC Manager) Page 11

Agenda 1 SIMOTION SCOUT TIA // TIA Portal 2 2 SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x 5 2.1 SIMOTION SCOUT TIA V4.4 HF1/2 // TIA Portal V13 7 2.2 SIMOTION SCOUT TIA V4.4 HF4 // TIA Portal V13 9 2.3 SIMOTION SCOUT TIA V4.4 HF5 // TIA Portal V13 SP1 12 2.4 SIMOTION SCOUT TIA V4.4 HF6 // TIA Portal V13 SP1 16 2.5 SIMOTION SCOUT TIA V4.4 HF8/HF11 // TIA Portal V13 SP1 19 3 SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x 21 Page 12

SIMOTION SCOUT TIA V4.4 HF5 // TIA Portal V13 SP1 (February 2015) Installation TIA Portal framework V13 SP1 requires from all clients (Step7/WinCC/Startdrive/.) a new version. Therefore you need at least the version SCOUT TIA V4.4 HF5 to handle SIMOTION inside V13 SP1. Hints: TIA Portal framework V13 SP1 does not work with an installed SCOUT TIA < V4.4 HF5. The same applies to the Migration-Tool V13 SP1. This requires the SIMOTION SCOUT Migration-Tool Plugin V4.4 HF5. side-by-side installation of SCOUT V4.4 HF2 or HF4 and SCOUT TIA V4.4 HF5 is possible. Page 13

SIMOTION SCOUT TIA V4.4 HF5 // TIA Portal V13 SP1 (February 2015) Main new features of HF5 compared to HF4 (Overview) Main new features of V4.4 HF5 (V13 SP1) compared to V4.4 HF4 (V13): PROFINET: F-Proxy via GSDML. (I-Device / Safety) For example in the case of using inside another project and as clock cycle IRT-I-device. PROFINET: Max. 128 sub-slots on the I-Device interface, of these max. 64 Safety axes. (I-Device / Safety) And so, it is like SIMOTION SCOUT inside SIMATIC Manager. ONLINE: Access via alternative access point (Device interface) Readiness Check Tool of the TIA Portal: The SIMOTION devices are integrated from V13 SP1 onwards Page 14

SIMOTION SCOUT TIA V4.4 HF5 // TIA Portal V13 SP1 (February 2015) Non supported features (Overview) Main non supported features of SCOUT TIA regarding SCOUT (SIMATIC Manager) and TIA Portal: DCC (Drive Control Chart) SIMOTION / SINAMICS Scripting of HWCN data TIA Portal (devices, communication). Therefore SIMOTION project generator and device update tool cannot be used. XML Export/Import of HWCN data is not supported inside TIA Portal (Hint: XML- Export/-Import of the SCOUT TIA data is possible) Upload of HWCN data TIA Portal of SIMOTION devices (Hint: Upload of the SCOUT TIA data is possible) PROFIBUS: F-Proxy as I-Slave, PROFIsafe slave -to- I-slave communication (F-DX, F-CPU to drive, e.g. ET- 2xx F<>SIMOTION drive S120), slave -to- slave communication (DX) Hint: F-Proxy as I-Device (PROFINET) is possible PROFINET: Media redundancy MRPD (Hint: MRP-Client is possible), Shared-I-Device, Shared device (e.g. S120 or ET2xx) below a SIMOTION-CPU Page 15

Agenda 1 SIMOTION SCOUT TIA // TIA Portal 2 2 SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x 5 2.1 SIMOTION SCOUT TIA V4.4 HF1/2 // TIA Portal V13 7 2.2 SIMOTION SCOUT TIA V4.4 HF4 // TIA Portal V13 9 2.3 SIMOTION SCOUT TIA V4.4 HF5 // TIA Portal V13 SP1 12 2.4 SIMOTION SCOUT TIA V4.4 HF6 // TIA Portal V13 SP1 16 2.5 SIMOTION SCOUT TIA V4.4 HF8/HF11 // TIA Portal V13 SP1 19 3 SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x 21 Page 16

SIMOTION SCOUT TIA V4.4 HF6 // TIA Portal V13 SP1 (May 2015) Main new features of HF6 compared to HF5 (Overview) Main new features of V4.4 HF6 (V13 SP1) compared to V4.4 HF5 (V13 SP1): Support of ET 200SP TM Timer DI/DQ and ET 200MP TM Timer DI/DQ Time-based I/O: High-precision measuring inputs and output cams. Symbolic connection of SIMOTION is possible. PROFIBUS: PROFIsafe slave -to- I-slave communication (F-DX, F-CPU to drive, e.g. ET-2xx F<>SIMOTION drive S120) Page 17

SIMOTION SCOUT TIA V4.4 HF6 // TIA Portal V13 SP1 (May 2015) Non supported features (Overview) Main non supported features of SCOUT TIA regarding SCOUT (SIMATIC Manager) and TIA Portal: DCC (Drive Control Chart) SIMOTION / SINAMICS Scripting of HWCN data TIA Portal (devices, communication). Therefore SIMOTION project generator and device update tool cannot be used. XML Export/Import of HWCN data is not supported inside TIA Portal (Hint: XML- Export/-Import of the SCOUT TIA data is possible) Upload of HWCN data TIA Portal of SIMOTION devices (Hint: Upload of the SCOUT TIA data is possible) PROFIBUS: F-Proxy as I-Slave, slave -to- slave communication (DX) Hint: F-Proxy as I-Device (PROFINET) is possible PROFINET: Media redundancy MRPD (Hint: MRP-Client is possible), Shared-I-Device, Shared device (e.g. S120 or ET2xx) below a SIMOTION-CPU Page 18

Agenda 1 SIMOTION SCOUT TIA // TIA Portal 2 2 SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x 5 2.1 SIMOTION SCOUT TIA V4.4 HF1/2 // TIA Portal V13 7 2.2 SIMOTION SCOUT TIA V4.4 HF4 // TIA Portal V13 9 2.3 SIMOTION SCOUT TIA V4.4 HF5 // TIA Portal V13 SP1 12 2.4 SIMOTION SCOUT TIA V4.4 HF6 // TIA Portal V13 SP1 16 2.5 SIMOTION SCOUT TIA V4.4 HF8/HF11 // TIA Portal V13 SP1 19 3 SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x 21 Page 19

SIMOTION SCOUT TIA V4.4 HF8/HF11 // TIA Portal V13 SP1 Features of HF8/HF11 compared to HF6 (Overview) The supported and non supported features of V4.4 HF8 (September 2015) and of V4.4 HF11 (December 2015) are the same as V4.4 HF6. V4.4 HF8 and HF11 eliminates only various functional restrictions. Page 20

Agenda 1 SIMOTION SCOUT TIA // TIA Portal 2 2 SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x 5 3 SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x 21 3.1 SIMOTION SCOUT TIA V4.5 HF1 // TIA Portal V14 Upd1 23 Page 21

SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x (in general) Supported Runtime, Project version, Operating system and Hardware Supported Runtime / Project version / Operating system: Runtime-versions: V4.3, V4.4, V4.5 (and SIMOTION Drives of the type SINAMICS S120 V4.5, V4.7, V4.8) Project version: V4.5/V14 Operating system for SCOUT TIA: Win7 SP1 (Professional, Enterprise, Ultimate) (64 bit) ; Win8.1 (Professional, Enterprise) (64 bit); additionally Win10 (Professional, Enterprise) (64 bit) is planned with the upcoming version V5.1/V14 SP1 Supported Hardware (included in the delivery package - part SCOUT TIA): SIMOTION D4xx-2 / CX32-2 SIMOTION Drives: SINAMICS S120, only if this drive is connected to a SIMOTION-CPU via PROFIBUS/PROFINET SIMOTION C240 / C240 PN SIMOTION P320-4 (Embedded, Standard) (from runtime-version V4.5 onwards) Hint: Of course, the Startdrive-G120-drives inside the TIA Portal can also be used in conjunction with SIMOTION. But the Drives of Startdrive and GSD-drives do not support the F-Proxy concept. The Startdrive-S120-drives support only the operation with S7-1500. Hint: An upgrade to TIA Portal V14 is performed exclusively on the basis of TIA Portal V13 SP1 projects. TIA Portal V14 does not support a compatibility mode. Hint: SCOUT TIA version V4.5 works with the license (key) of V4.4. New license is not necessary! Page 22

Agenda 1 SIMOTION SCOUT TIA // TIA Portal 2 2 SIMOTION SCOUT TIA V4.4.x // TIA Portal V13.x 5 3 SIMOTION SCOUT TIA V4.5.x // TIA Portal V14.x 21 3.1 SIMOTION SCOUT TIA V4.5 HF1 // TIA Portal V14 Upd1 23 Page 23

SIMOTION SCOUT TIA V4.5 HF1 // TIA Portal V14 Upd1 (December 2016) Main new features of V4.5 HF1 compared to V4.4 (Overview) Main new features of V4.5 HF1 (V14) compared to V4.4 (V13 SP1): Upload HWCN data (with upcoming V14 Upd2): SIMOTION devices (including SIMOTION drives) Hardware: Support of SIMOTION PC-Based (P320-4) PROFINET: Shared-I-Device, Shared device (e.g. ET200SP) below a SIMOTION-CPU It is possible to use it in separate projects (not inside the same project). Shared device is not possible in connection with SINAMICS S120. PROFINET: Seamless Media Redundancy MRPD PROFINET: Automatic settings via engineered topology - Check of VendorID/DeviceID for Automatic Assignment of NameOfStation PROFINET: Max. 128 sub-slots on the I-Device interface, of these max. 128 Safety axes. (I-Device / Safety) (Exception: SIMOTION PC-Based supports only max. 64 Safety axes) Page 24

SIMOTION SCOUT TIA V4.5 HF1 // TIA Portal V14 Upd1 (December 2016) Main new features of V4.5 HF1 compared to V4.4 (Overview) Main new features of V4.5 HF1 (V14) compared to V4.4 (V13 SP1): Openness: Scripting SCOUT TIA data But Scripting of HWCN data TIA Portal is not complete. PROFIdrive alarms for SIMOTION Drives (S120-CU3x0-2) Device Upgrade Tool is supported. Page 25

SIMOTION SCOUT TIA V4.5 HF1 // TIA Portal V14 Upd1 (December 2016) Main new features of V4.5 HF1 compared to V4.4 (Overview) Main new features of V4.5 HF1 (V14) compared to V4.4 (V13 SP1): This features are not available with SCOUT (SIMATIC Manager environment) PROFINET: Performance Upgrade for SIMOTION D455-2 (IRT+, SendClock 125) Only with Servo-Fast and ET200SP. PROFINET: Automatic settings via engineered topology - Overwriting of the NameOfStation PROFINET: New feature regarding series and modular machines - Addresstailoring for IO-Controller and IO-Devices. Automatic assignment of NameOfStation and IP-Adress of multiple machine instances in the same network without having access to the engineering project Page 26

SIMOTION SCOUT TIA V4.5 HF1 // TIA Portal V14 Upd1 (December 2016) Non supported features (Overview) Main non supported features of SCOUT TIA regarding SCOUT (SIMATIC Manager) and TIA Portal: DCC (Drive Control Chart) SIMOTION / SINAMICS XML Export/Import of HWCN data is not supported inside TIA Portal (Hint: XML- Export/-Import of the SCOUT TIA data is possible) PROFIBUS: F-Proxy as I-Slave, slave -to- slave communication (DX) Hint: F-Proxy as I-Device (PROFINET) is possible Openness (Scripting) of HWCN data TIA Portal (devices, communication). For example if you have PROFINET isochronous IRT. Therefore SIMOTION project generator cannot be used. PROFINET: Shared device in connection with SINAMICS S120 below a SIMOTION-CPU Page 27

Thank you for the attention DF FA PMA SP1 Uwe Schmidt Siemens provides automation and drive products with industrial security functions that support the secure operation of plants or machines. They are an important component in a holistic industrial security concept. With this in mind, our products undergo continuous development. We therefore recommend that you keep yourself informed with respect to our product updates. Further information can be found at: http://support.automation.siemens.com. You can also register for a product-specific newsletter there. To ensure the secure operation of a plant or machine it is also necessary to take suitable preventive action (e.g. cell protection concept) and to integrate the automation and drive components into a state-of-the-art holistic industrial security concept for the entire plant or machine. Any third-party products that may be in use must also be taken into account. Further information can be found at: http://www.siemens.com/industrialsecurity siemens.com Page 28