LOGAN SCHOOL SCHOOL WITHOUT WALLS AT LOGAN

Similar documents
BALLOU SENIOR HIGH SCHOOL

EASTERN HIGH SCHOOL. Site Plan East Capitol Street, N.E., Washington, DC INITIAL YEAR BUILT 1923

SEATON ELEMENTARY SCHOOL

COOLIDGE SENIOR HIGH SCHOOL

POWELL ELEMENTARY SCHOOL

DAVIS ELEMENTARY SCHOOL

RAYMOND EDUCATION CAMPUS

SHEPHERD ELEMENTARY SCHOOL

STUART-HOBSON MIDDLE SCHOOL

School Without Walls

LASALLE - BACKUS EDUCATION CAMPUS

MAURY ELEMENTARY SCHOOL

LEWIS ELEMENTARY SCHOOL

WILKINSON ELEMENTARY SCHOOL

LECKIE ELEMENTARY SCHOOL

NALLE ELEMENTARY SCHOOL

WATKINS ELEMENTARY SCHOOL

PLUMMER ELEMENTARY SCHOOL

PATTERSON ELEMENTARY SCHOOL

BARNARD ELEMENTARY SCHOOL

GARFIELD ELEMENTARY SCHOOL

NOYES EDUCATION CAMPUS

KEY ELEMENTARY SCHOOL

WALKER-JONES EDUCATION CAMPUS

Chenango Valley Central School District Potential Capital Project BCK-IBI Group Project No October 23, 2017

Toronto Community Housing Executive Summary 2016/2017. BCA Report. Sample House High FCI

Collins Middle School

Corsicana High School

Facilities Feasibility Study Frederick Douglass HS Condition Assessment

BRUCE-MONROE ELEMENTARY SCHOOL AT PARK VIEW MODERNIZATION HISTORIC PRESERVATION REVIEW

Deficiency ID Qty UoM Priority. K Play Area Requires Impact Resistant Material Ea. 2

HILLSIDE ELEMENTARY SCHOOL. Overview: Livingston School District Hillside Elementary School

Deferred Maintenance Plan

Existing Site Aerial Frederick High School Feasibility Study September 5, 2012

FACILITY COMPONENTS - ELEMENTARY SCHOOL

TABLE OF CONTENTS Page

Dr. Edward Livingston Trudeau Building. 118 Main Street, Saranac Lake, NY. Building Systems Report. June 24, 2018

Health Life Safety Survey and Master Facilities Plan

Board Work Session Feasibility Study. January 9, 2017

HUGHES STADIUM CONTROLLED MAINTENANCE THROUGH 2020 Description of Projects on Facilities Management List September 18, 2014

NYC Department of Education

BOWIE LEARNING CENTER

Deficiency ID Qty UoM Priority. Concrete Walks Are Damaged And Require Replacement ,000 SF 3

FACILITY COMPONENTS - ELEMENTARY SCHOOL

MADELEY RANCH ELEMENTARY SCHOOL

Facilities Feasibility Study Matthew A. Henson ES Condition Assessment

Lake Highlands North Recreation Center Summary

FACILITY COMPONENTS - MIDDLE SCHOOL

Thurgood Marshall Recreation Center Summary

NYC Department of Education

Rental Inspection Checklist

Facilities Feasibility Study Laurence G. Paquin Building Condition Assessment

K.B. Polk Recreation Center Summary

Beckley-Saner Recreation Center Summary

School Assessment Report

HERITAGE MIDDLE SCHOOL. Overview: Livingston School District Heritage Middle School

Biddeford School Department

NYC Department of Education

Waverley Elementary School Feasibility Study

TABLE OF CONTENTS. Calgary School District No. 19 March Page. Executive Summary. Facility Profile and Summary 1. Section 1 Site Conditions 4

Reilly Elementary School Site Summary

Timberglen Recreation Center Summary

GFW Schools Task Force Meeting 1/23/19 R.A. MORTON & ASSOCIATES GLT ARCHITECTS 1

NYC Department of Education

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

School Assessment Report

SITE AND BUILDING INSPECTION CHECKLIST

School Assessment Report

NYC Department of Education

Project Scope & Budget Breakdown. Mandatory Scope Recommended Additional Scope Wish List Scope

Walter Q Gresham Elementary School

BRUCE MONROE AT PARK VIEW ELEMENTARY SCHOOL MODERNIZATION PROPOSED MAIN ENTRY - EXTERIOR RENDERING

NYC Department of Education

NYC Department of Education

Amos Alonzo Stagg Elementary School 7424 S Morgan St Chicago, IL 60621

NYC Department of Education

3. 21st Century Learning A. Districtwide Flexible Learning $600,000 Subtotal $600,000

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

NYC Department of Education

Menchaca Elementary School Site Summary

Mills Elementary School Site Summary

NYC Department of Education

NYC Department of Education

DENNIS TOWNSHIP FEASIBILITY STUDY

Facility Condition Assessment Dr. Harry L. Halliwell Memorial School

NYC Department of Education

Evansville Public Schools. Facility Assessment Report January 28, 2 , General Building Data

Louis A Agassiz Elementary School

NYC Department of Education

NYC Department of Education

Appendix J - Custom Uniformat for EDU Migration

NYC Department of Education

Darlington Area Schools - Building Evaluations

Architect and Engineer: Friar Associates inc.

2016 BOND INFORMATION

NYC Department of Education

DISTRICT SERVICES BUILDING

NYC Department of Education

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

Arts Center- Building needs

Transcription:

INITIAL YEAR BUILT 1935 BUILDING AREA 47,200 SF CURRENT PROGRAM CAPACITY 479 ENROLLMENT 2008 418 WARD 6 PROPOSED PROGRAM CAPACITY 450 Site Plan LOGAN - 1

PROPOSED PROGRAM PROFILE GRADE CONFIGURATION HS 9-12 (Swing) SQ. FT. (EXISTING) 47,200 SQ. FT. (ADDITION) TYPE PROPOSED TYPE PROPOSED Academic Classrooms 14 Science 3 Special Education 1 Visual Arts 1 Band/Instrument/Choral 1 Gymnasium Auxiliary Gymnasium Fitness Multi-Purpose 1 Technical Labs 1 Main Office 1 Media Center 1 Administrative/Health Suite 1 Cafeteria Kitchen Proposed Planning Profiles The inventory of spaces listed here is intended to outline the program of educational and support spaces necessary to support the proposed program capacity. Individual educational specifications and facility programs will be developed with the School Improvement and School Planning / Design teams at the time of project initiation. LOGAN - 2

CONDITION ASSESSMENT Building System ADA Compliance Conveying Systems Electrical Exterior Finish HVAC Interior Finish Plumbing Roof Structure Technology 2008 Rating Unsatisfactory Unsatisfactory Poor Poor Fair Fair Fair Good Poor Poor Comments: 1 Conveying System There are no elevators, escalators, or lift systems in the building. 2 Electrical 3 Exterior Finish 4 Structure 5 HVAC The electrical distribution system in the original building was upgraded relatively recently. The overall quality and functionality of the electrical system installation ranges from fair to poor. The conduit is unsightly. At a number of rooms, surface-mounted conduit and receptacles on the floor are a tripping hazard. There are numerous penetrations through walls and floors that should be fire-rated (as well as smoke partitions). Circuit breakers frequently trip; there is an insufficient number of receptacles. Major components appear to be in good condition, as is most of the electrical distribution system. The existing fire alarm system is obsolete and needs to be replaced. There is an emergency generator, probably installed as part of the upgrade. 2007: Fire alarm system, PA enhancement, electrical, lighting replacement. At the main building, wood trim is deteriorating and in unsatisfactory condition due to water damage. The windows are typically in unsatisfactory condition. About 25% of the brick and 100% of the limestone on the main building needs repainting. The exterior of the demountable building is in fair condition. Exterior metal siding was painted over peeling paint, which continues to peel. 2007: Fencing, Fire Alarm system enhancement, PA enhancement. Exterior paint doors, windows. Overall, the structure at the main building appears to be sound. The east wing has some settlement cracks in the CMU at both the north and south ends. The stone veneer at the foundation of the main building is in poor condition. Some of the stone is spalling and 100% needs repainting. The main building has a steam heating system consisting of a mixture (often all in the same room) of radiators, cabinet unit heaters, and aluminum finned heat convectors. All classrooms are over-heated, particularly at the east wing (some rooms are around 95 F). The excess heat, combined with moisture penetration, is highly conducive to mold growth; a stale odor prevails. The survey team is concerned as to the suitability of these conditions for a learning environment for either children or adults. All heating system piping is old. It appears that only steam boilers are reusable. Window air conditioners and portable air conditioner units are used. 2008: Repairs to boilers and classroom heating units. Installed 46 window A/C units. LOGAN - 3

6 Interior Finish 7 Plumbing 8 Roof 9 ADA Compliance 10 Technology 11 Grounds At the main building, the interior condition ranges from poor to unsatisfactory. Water damage at the west wing and auditorium has caused significant damage to the plaster walls and ceilings which in some areas is an immediate life safety issue. Moisture penetration at the east wing has caused extensive peeling paint and mold growth on painted brick walls. Plaster ceilings at the east wing were repaired within the past 2-3 years; however, the leaks causing the plaster damage were reportedly not repaired, as evidenced by paint that is again starting to peel. Classroom carpeting ranges from poor to unsatisfactory condition. 2007: Plaster repair, painting, flooring and whiteboards. Generally speaking, school plumbing fixtures are in poor condition. Some water closets and fountains are not working. Domestic water service is made of galvanized steel in violation of current DC Code requirements. 2007: Plumbing improvements. Repair and replace toilet partitions. The slate roofs on the main building are in fair condition, with cracked, missing, or broken slates that need to be replaced. The built-in gutters, copper gutter liners, and downspouts at the perimeter of the slate roofs are in unsatisfactory condition, resulting in extensive interior wall leakage and deterioration of the exterior wood cornice and dentils. The flat roofs on the main building are modified bitumen roof membranes applied over built-up membranes. There appear to be a number of active leaks under these roofs in the auditorium and central hallway. The modified bitumen roofs are in poor condition and were poorly flashed. The two cupolas located at the center of each side wing are in urgent need of maintenance and painting. The flat locked and soldered seam copper roofs on the top of the cupolas are in fair condition. The flat locked and soldered seam copper roofs over the entrance porches and bay windows are in fair condition. The main building has one accessible entry at the north side; however the majority of the doors and therefore the adjacent spaces do not comply with ADA. The second floor is completely inaccessible. The telephone and data system needs major renovation at the main building. There is loose cabling and wiring throughout the building, with a number of conduits detached from walls and ceilings. There is no wireless computer network at the main building. The grounds are generally in poor condition. Sidewalks, curbs, and paving are deteriorating and should be repaired in the near future. There are no athletic fields and only one small playground. This play structure is in overall good condition; however the padding surface has localized damage. LOGAN - 4

RECENT HISTORY OF MODERNIZATION 2008 STABILIZATIONS AC Window Units Installations & Electrical Upgrades LEGACY PROJECTS - OTHER STABLIZATIONS Interior Renovations - Various (Swing Spaces/Libraries/Asst. Supt. Offices) Roof Replacements Planning Design Pre-Construction In Progress Completed LOGAN - 5

Basement Concept Plans These floor plans represent planning concepts for proposed facility use, aligning the proposed program capacity, the proposed planning profiles, and the conceptual reconfiguration of the building. Each project is subject to a formal design process, incorporating input from the School Improvement team at the time of project initiation. LOGAN - 6

First Floor Concept Plans These floor plans represent planning concepts for proposed facility use, aligning the proposed program capacity, the proposed planning profiles, and the conceptual reconfiguration of the building. Each project is subject to a formal design process, incorporating input from the School Improvement team at the time of project initiation. LOGAN - 7

Second Floor Concept Plans These floor plans represent planning concepts for proposed facility use, aligning the proposed program capacity, the proposed planning profiles, and the conceptual reconfiguration of the building. Each project is subject to a formal design process, incorporating input from the School Improvement team at the time of project initiation. LOGAN - 8