CITY OF NOVI. Police Department

Similar documents
RAYMOND EDUCATION CAMPUS

NALLE ELEMENTARY SCHOOL

LASALLE - BACKUS EDUCATION CAMPUS

Chenango Valley Central School District Potential Capital Project BCK-IBI Group Project No October 23, 2017

FACILITY COMPONENTS - MIDDLE SCHOOL

Collins Middle School

Facility Improvements

SEATON ELEMENTARY SCHOOL

BENSON CITY HALL/POLICE DEPARTMENT FACILITY ASSESSMENT AND FEASIBILITY STUDY

WATKINS ELEMENTARY SCHOOL

Evansville Public Schools. Facility Assessment Report January 28, 2 , General Building Data

BALLOU SENIOR HIGH SCHOOL

Minuteman Regional Vocational Technical School

POWELL ELEMENTARY SCHOOL

LOGAN SCHOOL SCHOOL WITHOUT WALLS AT LOGAN

260,000 SF Building Profile

FACILITY COMPONENTS - ELEMENTARY SCHOOL

Facilities Feasibility Study Frederick Douglass HS Condition Assessment

CITY OF CHARLOTTESVILLE DEPARTMENT OF PUBLIC WORKS

Arts Center- Building needs

2017 City of Ortonville Northridge Study

FACILITY COMPONENTS - ELEMENTARY SCHOOL

WILKINSON ELEMENTARY SCHOOL

LEWIS ELEMENTARY SCHOOL

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

HUGHES STADIUM CONTROLLED MAINTENANCE THROUGH 2020 Description of Projects on Facilities Management List September 18, 2014

Timberglen Recreation Center Summary

School Without Walls

Expanding Your Development & Investment Perspectives 159,000 SF Building Profile

HERITAGE MIDDLE SCHOOL. Overview: Livingston School District Heritage Middle School

WI , 2018 R100

HILLSIDE ELEMENTARY SCHOOL. Overview: Livingston School District Hillside Elementary School

JV PROPERTIES, LLC (AQUA GLASS/MASCO) 320 INDUSTRIAL ROAD ADAMSVILLE, MCNAIRY COUNTY, TN Approximately 511,807 square feet

Assessment Report Burgess Park Gymnasium. Summary

building audit & site analysis

Dr. Edward Livingston Trudeau Building. 118 Main Street, Saranac Lake, NY. Building Systems Report. June 24, 2018

Corsicana High School

CENTENNIAL SCHOOL DISTRICT

43. CONSERVATORY. Conservatory. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

Facilities Feasibility Study Laurence G. Paquin Building Condition Assessment

DAVIS ELEMENTARY SCHOOL

EASTERN HIGH SCHOOL. Site Plan East Capitol Street, N.E., Washington, DC INITIAL YEAR BUILT 1923

PLUMMER ELEMENTARY SCHOOL

COOLIDGE SENIOR HIGH SCHOOL

Existing Site Aerial Frederick High School Feasibility Study September 5, 2012

GFW Schools Task Force Meeting 1/23/19 R.A. MORTON & ASSOCIATES GLT ARCHITECTS 1

Watercrest - Sand Hill - Columbia, SC TABLE OF CONTENTS PROCUREMENT AND CONTRACTING REQUIREMENTS

CHANCELLORS RESIDENCE ANNUAL INSPECTION REPORT BY BOT GOVERNANCE COMMITTEE MEMBERS A. ITEMS FROM PREVIOUS SITE INSPECTIONS-INCOMPLETE OR ON HOLD

School Assessment Report

Funding Source. Ranking

Facility Assessment Report, Montgomery Independent School District

Appendix J - Custom Uniformat for EDU Migration

NYC Department of Education

School Assessment Report

Hinsdale Township High School District 86 Referendum Project Listing April 2, Approved

NC State University Design and Construction Guidelines Division 00 Planning & Design Space Planning

TABLE OF CONTENTS Page

SYLVAN. inspire MIDDLE SCHOOL. which is to. instruction and programs. in a safe, caring, and. collaborative learning community.

DENNIS TOWNSHIP FEASIBILITY STUDY

Town Office Building, 17 School Road, Community Room, addition completed 2007

Superintendent Proposed Capital Improvements Program. Fiscal Years

Edmonton Public School District No. 7

STUART-HOBSON MIDDLE SCHOOL

NYC Department of Education

PRESENTATION JANUARY 24, 2017

Alabama Home Inspections

LECKIE ELEMENTARY SCHOOL

Deficiency ID Qty UoM Priority. K Play Area Requires Impact Resistant Material Ea. 2

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

Building Inspection Report

School Assessment Report

NYC Department of Education

PROCUREMENT AND CONTRACTING DOCUMENTS GROUP

N o v e m b e r

Board Work Session Feasibility Study. January 9, 2017

School Assessment Report

Overbrook Theater / Fruenthal Foundation Art Center. 1.0 Total Points % 2.1 Building Exterior Elements %

LUFacilities Policy Service Level Agreement v1.1

Frederic Chopin Elementary School

School Assessment Report

Unity Office Building 400 Unity Street Latrobe, PA 15650

AIRWAYS CROSSING PHASE II BUILDING INFORMATION 5305 McCall Way N.E. T2E 7N7

Stevens High School Pre Bond Presentation Claremont, NH

NYC Department of Education

Deficiency ID Qty UoM Priority. Concrete Walks Are Damaged And Require Replacement ,000 SF 3

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

NYC Department of Education

Piping system (steam, hot water, chilled water system) including pipe and duct insulation needs replacement.

NYC Department of Education

Charles H Wacker Elementary School

Al Behrman Elementary School

This section applies to service areas and loading docks for new construction and major renovations.

FOR SALE. BHSMiami.com Miller Dr (SW 56 Street) Miami, FL 33156

Prepared by. Christopher La Follette. Fidelis Management, Inc.

County of Santa Barbara, California Facility Condition Assessment Total: $238,124. Appendix 1 Probable Cost Estimates Detail

K.B. Polk Recreation Center Summary

Main Floor Plan Scale: 1/8"=1'-0"

Morehouse School of Medicine

Space Program & Concept Design

Transcription:

CITY OF NOVI Police Department Indoor Gun Range and Training Facility Assessment Analysis with Master Plan for Novi Police Department at Community Build Out Field Services Complex Facility Needs Master Plan For presentation on November 20, 2006 1

City of Novi Police Department Indoor Gun Range and Training Facility Assessment Analysis with Master Plan for Novi Police Department at Community Build Out 2

MISSION To meet future public safety needs and city growth and then determine how the current facilities should be expanded. 3

Study Methodology Step 1: Current and Future Operations Growth Needs Analysis Step 2: Facility Analysis Program Analysis Step 3: Options Preferred Options Report 4

COMMITTEE PROCESS Dedicated Involvement Core Planning Group Novi Police Staff City Manager Over 12 Meetings Guiding Principles Police Core Planning Group Anticipate the policing needs of the City, the building needs to consider for the long-term build-out of the community. A facility the department and the citizens are proud of. Providing a welcoming environment, a safe haven for all. A facility that offers protection for citizens & the community; not intimidating. A facility that can bridge the officers with the community. Building to incorporate durable, high quality materials with attention to detail. Technologically advanced; state of the art. Fiscally responsible, not opulent or overbuilt. A facility that can promote community events, volunteerism, spirit of involvement. Novi Police front lobby / reception Striving for excellence by continuous improvement. The Golden Rule Treat others as you want to be treated. 5

FUTURE PROJECTIONS City of Novi Population Projections 2006: 54,423 2024: 68,059 EXISTING FUNCTIONAL ISSUES Circulation is inefficient. Building does not flow well. Locker rooms are undersized. Inadequate sally port space. HVAC control problems. Security deficiencies where public interacts. No Firearms Training System/Tactics/Media Room. Limited training space and storage space. Novi Police Staff Projections 2006: 70 sworn officers 29 civilian staff 2024: 102 sworn officers 34 civilian staff Current Novi Police Training Center 6

Tour Highlights As a part of the planning process, the CORE Planning Group visited several local facilities to gather information relevant to this project Troy Police Department Waterford Township Police Department Dearborn Heights Police Department Farmington Indoor Gun Range 7

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Troy Police Department Security measures Dedicated Multi-functional Media Room 8

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Troy Police Department Efficiently stored equipment Efficiently programmed crime lab located adjacent to property room 9

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Troy Police Department Kitchen off of Communications Center to enhance efficiency 10

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Troy Police Department Secure double vehicle sally port Interior of secure double vehicle sally port 11

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Troy Police Department Reclining Gran-Trap Range 12

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Waterford Township Police Department Security measures Secured inventory of weapons and equipment 13

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Waterford Township Police Department Individual shooting stalls Open range provides for flexibility in training with moving targets 14

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Waterford Township Police Department Controls allow for individual movement of each firing lane 15

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Dearborn Heights Police Department Security measures Dedicated EOC 16

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Dearborn Heights Police Department Dedicated FATS Room Dedicated Training Center 17

TOUR HIGHLIGHTS Core Planning Group Toured Four Facilities Dearborn Heights Police Department Secure double space vehicle sally port Range control room allows for movement of individual targets 18

TOUR HIGHLIGHTS Current Gun Range at Farmington DPW Control Room Control Panel 19

TOUR HIGHLIGHTS Current Gun Range at Farmington DPW Control Panel in Disrepair Antiquated System 20

TOUR HIGHLIGHTS Current Gun Range at Farmington DPW Targets will not edge Communication is limited 21

TOUR HIGHLIGHTS Current Gun Range at Farmington DPW Recycled air ventilation system with no filters Broken drop-down counters Lack of flexibility fixed firing positions 22

TOUR HIGHLIGHTS Current Gun Range at Farmington DPW All targets set at one distance Metal backstop causes lead to be released upon impact of fired rounds 23

PROGRAM ANALYSIS Space needs were determined through meetings with the Core Planning Group. Division Existing Program Need Detention Facilities 3,688 S.F. 4,203 S.F. Evidence 2,214 S.F. 2,716 S.F. Dispatch 953 S.F. 1,147 S.F. Support Services 2,649 S.F. 4,745 S.F. Lobby 759 S.F. 759 S.F. Uniform Division 2,205 S.F. 3,209 S.F. Fleet Maintenance 2,197 S.F. 2,197 S.F. Training 2,322 S.F. 5,225 S.F. Administration 2,633 S.F. 3,106 S.F. Records 1,445 S.F. 1,445 S.F. Investigation 3,036 S.F. 3,850 S.F. Building Services 1,352 S.F. 2,552 S.F. Indoor Gun Range 0 S.F. 5,108 S.F. TOTAL NET S.F. 25,273 S.F. 40,262 S.F. Circulation/Const. Factor 1.44 1.32 TOTAL GROSS S.F. 36,300 S.F. 53,080 S.F. 24

CURRENT POLICE HEADQUARTERS MAIN LEVEL FLOOR PLAN Floor Plan not shown 25

CURRENT POLICE HEADQUARTERS UPPER LEVEL FLOOR PLAN Floor Plan not shown 26

OPTION I: Complete Renovation and Full Build-Out INDOOR GUN RANGE AT THE FSC FACILITY SITE MAIN LEVEL FLOOR PLAN Floor Plan not shown Preliminary Cost Estimate Construction Cost $5,212,350.00 Project Cost $1,459,000.00 TOTAL $6,671,350.00* *Includes Indoor Gun Range Costs 27

OPTION I: Complete Renovation and Full Build-Out INDOOR GUN RANGE AT THE FSC FACILITY SITE UPPER LEVEL FLOOR PLAN Floor Plan not shown Preliminary Cost Estimate Construction Cost $5,212,350.00 Project Cost $1,459,000.00 TOTAL $6,671,350.00* *Includes Indoor Gun Range Costs 28

OPTION I: Complete Renovation and Full Build-Out INDOOR GUN RANGE AT THE FSC FACILITY SITE Gun Range Construction Costs Preliminary Cost Estimate Construction Cost $1,347,500.00 Project Cost $377,800.00 TOTAL $1,725,300.00 Site Development Costs Include: Ten Parking Spaces/ Drive Utility Connections Screening Berm to North Shift Recycle Center to West 29

OPTION I: Complete Renovation and Full Build-Out INDOOR GUN RANGE AT THE FSC FACILITY SITE Gun Range Construction Costs Preliminary Cost Estimate Construction Cost $1,347,500.00 Project Cost $377,800.00 TOTAL $1,725,300.00 Site Development Costs Include: Ten Parking Spaces/ Drive Utility Connections Screening Berm to North Shift Recycle Center to West 30

OPTION I: Complete Renovation and Full Build-Out INDOOR GUN RANGE AT THE FSC FACILITY SITE 31

OPTION II: Complete Renovation and Full Build-Out INDOOR GUN RANGE AT THE POLICE FACILITY SITE MAIN LEVEL FLOOR PLAN Floor Plan not shown Preliminary Cost Estimate Construction Cost $4,935,950.00 Project Cost $1,331,000.00 TOTAL $6,266,950.00 32

OPTION II: Complete Renovation and Full Build-Out INDOOR GUN RANGE AT THE POLICE FACILITY SITE UPPER LEVEL FLOOR PLAN Floor Plan not shown Preliminary Cost Estimate Construction Cost $4,935,950.00 Project Cost $1,331,000.00 TOTAL $6,266,950.00 33

OPTION II: Complete Renovation and Full Build-Out INDOOR GUN RANGE AT THE POLICE FACILITY SITE 34

OPTION III: Complete Renovation and Full Build-Out WITHOUT INDOOR GUN RANGE MAIN LEVEL FLOOR PLAN Floor Plan not shown Preliminary Cost Estimate Construction Cost $3,864,850.00 Project Cost $1,084,000.00 TOTAL $4,945,850.00 35

OPTION III: Complete Renovation and Full Build-Out WITHOUT INDOOR GUN RANGE UPPER LEVEL FLOOR PLAN Floor Plan not shown Preliminary Cost Estimate Construction Cost $3,864,850.00 Project Cost $1,084,000.00 TOTAL $4,945,850.00 36

OPTION III: Complete Renovation and Full Build-Out INDOOR GUN RANGE AT THE FSC FACILITY SITE 37

FACILITY ANALYSIS Site West parking lots and drop-off is in good condition. East parking lot experiences pooling of water. Exterior stoop outside mechanical room retains water. Fencing is in good condition. Exterior Brick veneer is in good condition. Upper level windows experience leaking / failed gaskets. Window soffits require some repair. Roof areas are in good condition with one problem area at level change. 38

FACILITY ANALYSIS Interior Interior finishes are in good condition and are well maintained. Casework is in good condition. Sergeants Office requires more efficient storage. Public counters lack security glass enhancements. Accessibility Accessible restrooms are available for public and staff. Original doors lack lever hardware. No clearance issues were observed. Elevator is available for second floor access. 39

FACILITY ANALYSIS Hazardous Materials No evidence of asbestos containing materials. Life Safety Fire alarm system was upgraded in 2000 with adequate expandability. Exit sign coverage is adequate. The boiler room has fire protection system. Inefficient storage space in gun armory Antiquated boiler controls for old pneumatic system 40

FACILITY ANALYSIS Electrical Systems Electrical service equipment is in fair condition. Finding replacement parts may be difficult. Light fixtures are in good condition. Generator is in good condition with some expandability. Dedicated receptacles should be provided where space heater use will continue. Mechanical Systems Heating & cooling zone control is inadequate. Minimal expandability exists with boiler plan. Pneumatic controls for building systems have been consistently problematic. Air handling units are aging. Replacement of unit components will extend lifecycle. Many fans are not working properly, compromising ventilation. Electrical Room Basement Mechanical Room 41

DRUG EDUCATION FACILITY ANALYSIS The Core Planning Group spoke with drug educators and Novi school officials Based on these discussions, it was learned that children learn best in small groups Novi school officials indicated that the auditorium located at the Novi Middle School is available for any special events involving groups of over 500 persons Novi Middle School Auditorium 42

City of Novi Police Department Question and Answer 43

City of Novi Field Services Complex Facility Needs Master Plan In Partnership with Parks, Recreation & Forestry Water and Sewer Engineering 44

FUTURE PROJECTIONS City of Novi Population Projections 2006: 54,423 2024: 68,059 EXISTING FUNCTIONAL ISSUES 1. Lack of sufficient space to store vehicles and equipment. 2. Current locker room, restrooms and lunch room space is limited. No central location for employee meetings and training. 3. Existing mechanical structures need repair or replacement. 4. Current layout of the facility allows visitors easy access to the site. 5. Current layout does not provide adequate site security Novi FSC Space Projections 2006: 33,860 square feet 10,200 square feet of cold storage 5.58 acres 2024: 93,250 square feet 25,400 square feet of cold storage 7.83 acres Vehicle maintenance garage 45

City of Novi Department of Public Works Main garage Water and sewer department Existing facility lunch rooms 46

City of Novi Department of Public Works DPW Parks, Recreation & Forestry Existing facility lunch rooms 47

City of Novi Department of Public Works Men s rest room Conference room 48

City of Novi Department of Public Works Forestry area Mezzanine storage 49

City of Novi Department of Public Works Sign shop Vehicle maintenance / tool crib area 50

City of Novi Department of Public Works Additional equipment and vehicle storage building Water and sewer department 51

City of Novi Department of Public Works Employee parking 52

City of Novi Department of Public Works Covered storage Recycling center 53

City of Novi Department of Public Works Vehicle maintenance area 54

City of Novi Department of Public Works Vehicle maintenance area 55

City of Novi Department of Public Works Vehicle maintenance area 56

City of Novi Department of Public Works Outside emergency generator storage Material storage 57

TOUR HIGHLIGHTS As a part of the planning process, the CORE Planning Group toured five local Department of Public Works facilities: Troy Auburn Hills Waterford Farmington Hills Taylor 58

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Troy Department of Public Works Employee lunch room Parks and Recreation outside repair area 59

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Troy Department of Public Works Vehicle maintenance area 60

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Auburn Hills Department of Public Works Lunch / break room Sign shop Mezzanine area Vehicle maintenance area 61

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Auburn Hills Department of Public Works Mezzanine storage DPW vehicle garage 62

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Auburn Hills Department of Public Works Covered outside material storage 63

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Auburn Hills Department of Public Works Vehicle maintenance area Vehicle / maintenance garage 64

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Waterford Township Department of Public Works Main entrance Administrative offices 65

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Waterford Township Department of Public Works Employee lunch room Vehicle maintenance area 66

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Farmington Hills Department of Public Works Covered vehicle storage 67

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Farmington Hills Department of Public Works Administrative offices 68

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Farmington Hills Department of Public Works Men s restroom Men s Locker room 69

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Farmington Hills Department of Public Works Employee lunch room 70

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Farmington Hills Department of Public Works Parts storage room 71

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Farmington Hills Department of Public Works Vehicle wash bay Vehicle/equipment storage garage 72

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Farmington Hills Department of Public Works Salt storage domes 73

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Taylor Department of Public Works Vehicle/equipment storage garage 74

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Taylor Department of Public Works DPW Directors office Covered vehicle parking and equipment storage 75

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Taylor Department of Public Works Covered material storage Vehicle maintenance bays 76

TOUR HIGHLIGHTS Core Planning Group Toured Five Facilities Taylor Department of Public Works Men's locker room 77

FACILITY ANALYSIS Site Paving is a combination of asphalt and concrete. Damage is present in several locations. Pedestrian traffic of visitors to the complex is not controlled. Visitors can access any part of the site thus compromising security and safety. Exterior FSC Building Exterior block is in good condition. Rust is occurring at the underside of the siding. Siding, otherwise, is in good condition. Brick requires tuck pointing outside of the Wash Bay. Exterior thresholds at the Wash Bay doors have moderate damage. Abandoned pipe penetration within the exterior wall outside of the Wash Bay doors requires patching. Facility entrance Wash bay 78

FACILITY ANALYSIS Exterior FSC Building (continued) The roofing system had previous leaks but has since been repaired. The exterior insulated glazing and aluminum framing window system condensates at various locations. Waste oil tank outside of the garage leaks oil and needs repair. The gaskets at the overhead door outside of the Forestry Garage needs repair. Significant leaking in atrium glass at visitors entrance. Office entrance Exterior Salt Dome The block and wood construction salt dome has damage and penetration within the roof and block wall. The existing metal flashing is rusted, damaged and missing in various locations. Salt storage dome 79

FACILITY ANALYSIS Exterior Enclosed Cold Storage Building The roofing, block, siding and overhead doors are in good condition. Interior FSC Building Surface rust is present on the existing steel framing system in the Forestry Garage, Fleet Maintenance Garage, Wash Bay and Mezzanine area. Accessibility FSC Building Accessibility to the existing Water/Sewer area, Storage/Tool Crib Room, Mezzanine, Parks/Recreation Garage does not occur at finish floor elevation changes. The existing hand rails at the Mezzanine stairs does not have the required top and bottom extension. Front office reception area Women s restroom 80

FACILITY ANALYSIS Hazardous Materials No evidence of asbestos containing materials. Life Safety Fire alarm system was upgraded in 2006. Exit sign coverage appears adequate. Electrical System Most mechanical systems are in need of repair or replacement. Locker area for employee uniforms Employee mailboxes 81

Proposed Main Level Plan MAIN LEVEL ADJOINING TO INDOOR GUN RANGE Floor plan not shown Option I Partial Build Out Preliminary Cost Estimate Construction Cost $6,108,000 Project Cost $1,525,000 TOTAL $7,633,000 (Does not include cost of Indoor Gun Range, nor the cost savings from site work and utilities by having already completed the indoor gun range) 82

Proposed Mezzanine Storage Area ABOVE PROPOSED BUILD OUT AND INDOOR GUN RANGE Floor Plan not shown Option I Partial Build Out Preliminary Cost Estimate Construction Cost $6,108,000 Project Cost $1,525,000 TOTAL $7,633,000 (Does not include cost of Indoor Gun Range, nor the cost savings from site work and utilities by having already completed the indoor gun range) 83

Proposed Main Level Plan MAIN LEVEL ADJOINING TO INDOOR GUN RANGE Floor Plan not shown Option II Complete Build Out with Future Development Preliminary Cost Estimate Construction Cost $8,752,000 Project Cost $2,187,000 TOTAL $10,939,000 (Does not include cost of Indoor Gun Range, nor the cost savings from site work and utilities by having already completed the indoor gun range) 84

Proposed Mezzanine Storage Area ABOVE PROPOSED BUILD OUT AND GUN RANGE Floor Plan not shown Option II Complete Build Out with Future Development Preliminary Cost Estimate Construction Cost $8,752,000 Project Cost $2,187,000 TOTAL $10,939,000 (Does not include cost of Indoor Gun Range, nor the cost savings from site work and utilities by having already completed the indoor gun range) 85

Proposed Main Level Plan MAIN LEVEL ADJOINING TO INDOOR GUN RANGE Floor Plan not shown Option III Complete Build Out Preliminary Cost Estimate Construction Cost $10,997,000 Project Cost $2,749,800 TOTAL $13,746,800 (Does not include cost of Indoor Gun Range, nor the cost savings from site work and utilities by having already completed the indoor gun range) 86

Proposed Mezzanine Storage Area ABOVE PROPOSED BUILD OUT AND GUN RANGE Floor Plan not shown Option III Complete Build Out Preliminary Cost Estimate Construction Cost $10,997,000 Project Cost $2,749,800 TOTAL $13,746,800 (Does not include cost of Indoor Gun Range, nor the cost savings from site work and utilities by having already completed the indoor gun range) 87

City of Novi Field Services Complex Question and Answer 88