NZQA registered unit standard version 1 Page 1 of 5. Diagnose and repair faulty electronic equipment to component level

Similar documents
NZQA registered unit standard 9537 version 5 Page 1 of 6. This unit standard applies to operational activities carried out on producing wellheads.

NZQA registered unit standard version 4 Page 1 of 5

NZQA registered unit standard version 1 Page 1 of 5

NZQA registered unit standard 9536 version 5 Page 1 of 6. Undertake petrochemical wellhead maintenance activities under supervision

NZQA registered unit standard version 3 Page 1 of 5. Demonstrate and apply advanced knowledge of power system engineering

NZQA registered unit standard 3851 version 7 Page 1 of 5. Service commercial refrigeration and/or air conditioning systems

NZQA registered unit standard 9506 version 5 Page 1 of 5. Conduct a sample analysis in a petrochemical laboratory

NZQA registered unit standard 6405 version 8 Page 1 of 5. Determine advertising options for small business enterprises. Marketing > Generic Marketing

NZQA registered unit standard version 4 Page 1 of 5. Carry out switching operations on metal clad switchgear

NZQA registered unit standard version 3 Page 1 of 5. Carry out automated assembly of wood packaging products

NZQA registered unit standard version 1 Page 1 of 5

NZQA registered unit standard version 1 Page 1 of 5. Develop, implement and review a HACCP application for a food processing operation

This unit standard is expiring

NZQA registered unit standard version 7 Page 1 of 5. Demonstrate and apply knowledge of safeguards for use with portable electrical appliances

NZQA registered unit standard version 2 Page 1 of 5

NZQA registered unit standard version 4 Page 1 of 5

NZQA registered unit standard version 1 Page 1 of 5. Identify and inspect road safety barrier systems on Infrastructure Works sites

NZQA registered unit standard version 3 Page 1 of 5. Install high voltage (HV) electricity network overhead conductors

NZQA registered unit standard version 3 Page 1 of 5

SECURITY STAFF SERVICES Demonstrate knowledge of and operate electronic equipment as a security officer

NZQA registered unit standard version 4 Page 1 of 6. Carry out acceptance, commissioning and maintenance tests on power transformers

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate and apply knowledge of maintenance plans for mechanical equipment and plant

NZQA registered unit standard version 4 Page 1 of 5. Operate power-operated elevating work platforms (EWP) in an electricity supply environment

NZQA registered unit standard version 1 Page 1 of 5

NZQA registered unit standard version 3 Page 1 of 5. Demonstrate and apply knowledge of costs to the pricing of a road transport service

NZQA Expiring unit standard 3885 version 8 Page 1 of 5. Demonstrate knowledge of and use an oxy-acetylene welding plant in the motor body industry

NZQA registered unit standard version 2 Page 1 of 6. Demonstrate professional and ethical behaviour as an engineering technician

NZQA registered unit standard version 5 Page 1 of 5. Manage hazard identification and control on plant and machinery

NZQA registered standard version 2 Page 1 of 7. Demonstrate and apply competence as an engineering technician

NZQA registered unit standard 5555 version 6 Page 1 of 5

NZQA registered unit standard version 6 Page 1 of 5

NZQA registered unit standard version 2 Page 1 of 5

NZQA registered unit standard 2930 version 5 Page 1 of 5

NZQA Expiring unit standard 3713 version 7 Page 1 of 6. Print single colour work on a sheet-fed registering offset press

NZQA Expiring unit standard version 6 Page 1 of 5. Operate a clamshell die cutter in the corrugated packaging industry

NZQA Expiring unit standard 2272 version 8 Page 1 of 5

NZQA registered unit standard version 2 Page 1 of 5. Generate chlorine dioxide for wood pulp bleaching

NZQA registered unit standard version 1 Page 1 of 6. Demonstrate knowledge of managing conflict situations in a security context

PUBLIC SECTOR SERVICE DELIVERY Establish client needs and gain agreement on requirements for public sector service delivery

NZQA registered unit standard version 2 Page 1 of 5. Demonstrate knowledge of safety management systems for an aviation environment

NZQA registered unit standard 3846 version 7 Page 1 of 7. Maintain commercial refrigeration and/or air conditioning systems

NZQA registered unit standard version 1 Page 1 of 5

NZQA Expiring unit standard version 2 Page 1 of 5. Describe metal roof and wall cladding preparation and installation procedures

NZQA registered unit standard version 2 Page 1 of 5. Operate x-ray and electronic scanning equipment in a prison environment

NZQA unit standard version 1 Page 1 of 7. Demonstrate knowledge of electromechanical engineering principles for technicians

NZQA registered unit standard version 2 Page 1 of 5. Complete pre-competition preparations as an official at a competitive sports event

NZQA registered unit standard version 4 Page 1 of 5

Demonstrate the requirements for holding permits on high voltage electrical equipment

NZQA registered unit standard version 6 Page 1 of 5. Operate biological treatment systems for effluent water in an energy and chemical plant

NZQA registered unit standard 1512 version 8 Page 1 of 6

ELECTRICITY SUPPLY - POWER SYSTEM MAINTENANCE Carry out routine inspection and servicing on high voltage minimum oil circuit breakers

NZQA registered unit standard Version 1 Page 1 of 5. Demonstrate operational knowledge of the law in a regulatory compliance context

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate knowledge of roof membrane systems

Carry out acceptance and maintenance tests on distance protection relays

NZQA registered unit standard version 3 Page 1 of 5

National Certificate in Concrete Product Manufacture (Masonry Product) (Level 3)

NZQA registered unit standard version 2 Page 1 of 5. Develop training and support programmes, and recruit, appoint, and manage CDEM volunteers

NZQA registered unit standard 6973 version 7 Page 1 of 5. Prune plantation trees with a chainsaw from the ground

NZQA registered unit standard version 2 Page 1 of 5. Describe the roles and functions of a CIMS Incident Management Team (IMT) at an incident

NZQA registered unit standard version 5 Page 1 of 5. Carry out the functions of the poleman on a cable harvesting landing

NZQA registered unit standard version 6 Page 1 of 6

This qualification has been revised. The last date to meet the requirements is 31 December 2021.

NZQA registered unit standard version 2 Page 1 of 5. Apply design principles in the design of scaffolding

NZQA registered unit standard version 2 Page 1 of 5. Create appointments and maintain appointment systems and records in the salon environment

NZQA registered unit standard version 2 Page 1 of 5. Describe drinking-water contaminants of public health significance

PUBLIC SECTOR SERVICE DELIVERY Develop public sector service delivery objectives, and implement systems to meet client needs

NZQA registered unit standard version 1 Page 1 of 5. Construction Trades > Painting and Decorating

NZQA registered unit standard 9184 version 6 Page 1 of 5

Install and commission high voltage (HV) electricity current transformer metering

NZQA registered unit standard 4884 version 7 Page 1 of 5. Recruit, induct, and manage volunteers in a recreation organisation

NZQA registered unit standard version 3 Page 1 of 5. Infrastructure Works > Civil Plant Operation

NZQA registered unit standard version 2 Page 1 of 5. Select and use tools and workshop equipment in the industrial textile fabrication industry

NZQA registered unit standard version 3 Page 1 of 5

NZQA registered unit standard version 5 Page 1 of 5. Make and repair a boat cockpit canopy and side curtains

NZQA registered unit standard version 1 Page 1 of 5. Interpret paving instructions and construct bituminous mix layers

NZQA registered unit standard version 4 Page 1 of 5. Forestry > Tree Felling

NZQA registered unit standard version 1 Page 1 of 7

QUALIFICATION HANDBOOK

NZQA registered unit standard version 3 Page 1 of 5

NZQA unit standard version 1 Page 1 of 5

NZQA Expiring unit standard version 2 Page 1 of 5. Demonstrate knowledge of liquid roof membrane systems

NZQA registered unit standard version 4 Page 1 of 5

Carry out routine inspection and servicing on high voltage bulk oil circuit breakers

ROAD TRANSPORT OPERATIONS Manage the transport of overdimension and overweight loads by road

NZQA registered unit standard version 5 Page 1 of 6. Operate hydro-electric generating plant from enterprise control room

SEG Awards ABC Level 3 NVQ Diploma in Manufacturing Textile Products

SEG Awards ABC Level 3 NVQ Diploma in Manufacturing Textile Products

NZQA registered unit standard version 1 Page 1 of 5. Determine and describe construction of medium and large buildings

NZQA registered unit standard 6945 version 7 Page 1 of 5. Forestry > Forest Mechanised Harvesting

NZQA registered unit standard 1243 version 8 Page 1 of 5. Forestry > Forest Silvicultural Operations

NZQA unit standard version 1 Page 1 of 5

NZQA registered unit standard version 1 Page 1 of 5

NZQA registered unit standard version 1 Page 1 of 6. Operate a bitumen distributor for blending and applying bituminous binders

This unit standard is expiring

NZQA unit standard version 5 Page 1 of 5. Prepare for and perform chemical analysis using optical emission spectrometry equipment

NZQA Expiring unit standard version 2 Page 1 of 5. Install and maintain roofing, rainwater handling, and cladding systems, and flashings

NZQA registered unit standard version 5 Page 1 of 5

NZQA registered unit standard version 1 Page 1 of 7. Fell trees in a commercial forest harvesting operation

NZQA registered unit standard version 1 Page 1 of 7. Plan and fell trees using advanced techniques in a commercial forest harvesting operation

NZQA registered unit standard version 2 Page 1 of 5

Transcription:

Page 1 of 5 Title Diagnose and repair faulty electronic equipment to component level Level 4 Credits 40 Purpose This unit standard is intended for electronics technicians who are responsible for the diagnosis and repair of consumer electronic equipment, industrial electronic equipment, or electronic telecommunications equipment, all to component level. People credited with this unit standard are able to: prepare to diagnose and repair electronic equipment; diagnose faults; repair and test electronic equipment; and complete post-repair procedures. Classification Electronic Engineering > Electronic Installation and Maintenance Available grade Achieved Entry information Recommended skills and knowledge Unit 26725, Demonstrate and apply knowledge of electronic product reliability and advanced electronic measurement and diagnosis, or demonstrate equivalent knowledge and skills. Explanatory notes 1 This unit standard has been developed for learning and assessment on-job and/or off-job using realistic simulation. 2 References Electricity Act 1992; Electricity (Safety) Regulations 2010; Health and Safety in Employment Act 1992 and associated regulations; IPC-7711/7721 B Rework, Modification and Repair of Electronic Assemblies. (November 2007); and all subsequent amendments and replacements.

Page 2 of 5 3 Definitions Consumer electronic equipment may include but is not limited to audio equipment, video equipment, and personal computer equipment. Industrial electronic equipment includes equipment used in the operation and control of industrial processes. Enterprise practice those practices and procedures that have been promulgated by the company or enterprise for use by their employees. Industry practice those practices that competent practitioners within the industry recognise as current industry best practice. PCB printed circuit board. Telecommunications equipment may include but is not limited to telephones, radio telephones, mobile phones. 4 For diagnosis and repair of more specific systems refer to the following unit standards: computing equipment standards 6873 and 6874; electronic office equipment standard 6066; marine electronic systems standards 11795 and 11796; radar standard 6061; communications equipment standard 26724. 5 a The type of diagnosis and repair work required to achieve this unit standard must include: i diagnosis and repair of equipment to component level; ii use of test instruments to identify faults, measure and adjust equipment, and confirm proper performance. Typical instruments include multimeters, oscilloscopes, signal generators, and signal tracers. More specialised instruments may be required depending on the nature of the equipment. b All diagnostic and repair work must be completed within an industry acceptable timeframe, that is, the length of time within which a competent person at this level could reasonably be expected to perform the task. In the electronics service industry, time is a significant factor in judging competence. Assessors must therefore ensure that the time taken is representative of industry expectations for the type of work. c Candidates are expected to meet the outcomes of this unit standard without direct technical supervision, and with complete responsibility for the quality and quantity of output. d Electrical, radiation, and workshop or laboratory safety practices are to be observed at all times. e Measurements may be expressed in Système Internationale (SI) or Imperial units, and, where required, converted from Imperial units to SI units and vice versa. f Recognised industrial standards are to be used for calculations. g All activities and evidence presented for all outcomes and evidence requirements in this unit standard must be in accordance with legislation, policies, procedures, ethical codes, Standards, applicable site and enterprise practice, and industry practice; and, where appropriate, manufacturers instructions, specifications, and data sheets. h Evidence for the number and type of equipment chosen is left to the discretion of the assessor, but must be sufficient to assess competence in all outcomes of the unit standard.

Page 3 of 5 Outcomes and evidence requirements Outcome 1 Prepare to diagnose and repair electronic equipment. 1.1 Fault symptoms are identified, and verified against the detailed fault description, and recorded. 1.2 Agreed expenditure and repair turn around time expectations are identified. 1.3 All site occupational safety and health implications for self and others are identified, and hazard control measures are put in place. 1.4 Service information, where appropriate, is made available before the commencement of fault diagnosis or repair. may include but is not limited to manuals, schematic diagrams, modification sheets, fault and service guides. Evidence of three is required. 1.5 Accessories are handled in a manner that prevents loss or damage. Outcome 2 Diagnose faults. 2.1 Cause of fault and faulty components are identified using efficient diagnostic techniques, tools, test instruments, and servicing data. 2.2 Repair feasibility is established with respect to agreed expenditure and repair reliability. 2.3 Anti-static precautions are observed to protect components from static damage as appropriate. includes but is not limited to packaging, storage, transport, handling. 2.4 Diagnostic processes do not damage the equipment. 2.5 Diagnostic report is in accordance with enterprise practice.

Page 4 of 5 Outcome 3 Repair and test electronic equipment. 3.1 Faulty components are replaced with components of equivalent or better performance ratings. 3.2 PCB repairs are made. may include but is not limited to components, conductors, solder. 3.3 Products or equipment are reassembled in a manner that prevents damage and conforms to the manufacturers' layout and maintain form fit and function of equipment. layout lead dress, screw location, shields and screens, board positioning and securing, cover positioning and fastening. 3.4 Testing confirms electrical safety. 3.5 Testing confirms that the repaired equipment is ready for service. Outcome 4 Complete post-repair procedures. 4.1 Repaired products or equipment are stored in a manner that prevents damage and complies with enterprise practice 4.2 Fault repair documentation is in accordance with enterprise practice. may include but is not limited to workshop register, job card, invoice, order forms, warranty forms, fault manuals, fault database, instructions to customer or front line technician. Evidence of two is required. Replacement information This unit standard replaced unit standard 20723, unit standard 20724, and unit standard 20725. Planned review date 31 December 2016 Status information and last date for assessment for superseded versions Process Version Date Last Date for Assessment

Page 5 of 5 Process Version Date Last Date for Assessment Registration 1 21 July 2011 N/A Consent and Moderation Requirements (CMR) reference 0003 This CMR can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Please note Providers must be granted consent to assess against standards (accredited) by NZQA, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be granted consent to assess against standards by NZQA before they can register credits from assessment against unit standards. Providers and Industry Training Organisations, which have been granted consent and which are assessing against unit standards must engage with the moderation system that applies to those standards. Requirements for consent to assess and an outline of the moderation system that applies to this standard are outlined in the Consent and Moderation Requirements (CMRs). The CMR also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact the reviewcomments@etito.co.nz if you wish to suggest changes to the content of this unit standard.