BJUI. Study Type Aetiology (case series) Level of Evidence 4 OBJECTIVE

Size: px
Start display at page:

Download "BJUI. Study Type Aetiology (case series) Level of Evidence 4 OBJECTIVE"

Transcription

1 2009 BJU INTERNATIONAL. Original Article BACH ET AL. BJUI BJU INTERNATIONAL 70 vs 120 W thulium:yttrium-aluminiumgarnet 2 μm continuous-wave laser for the treatment of benign prostatic hyperplasia: a systematic ex-vivo evaluation Thorsten Bach*, Nina Huck*, Felix Wezel*, Axel Häcker*, Andreas J. Gross and Maurice Stephan Michel* *Department of Urology, University Medical Centre Mannheim, Mannheim, and Department of Urology, Asklepios Hospital Barmbek, Hamburg, Germany Accepted for publication 10 September 2009 Study Type Aetiology (case series) Level of Evidence 4 OBJECTIVE To evaluate the ablative and haemostatic properties of the recently introduced 120-W thulium:yttrium-aluminium-garnet (Tm- YAG) laser and to assess these results against those of the previously introduced 70-W Tm- YAG laser. MATERIALS AND METHODS The ex-vivo model of the isolated bloodperfused porcine kidney was used to determine the ablation capacity, haemostatic properties and coagulation depth of a 2 μm continuous-wave Tm-YAG laser. The energy was delivered using a 550-μm and an 800- μm bare-ended fibre. The results of the recently introduced 120-W Tm-YAG were compared to the established 70-W device. Kidney tissue was embedded for histological evaluation. After staining (haematoxylin and eosin, H&E; and NADH) of the specimen, the coagulation zone and depth of the necrotic tissue layer were measured. RESULTS With increased power output, the mean (SD) rate of vaporization of tissue increased, from 9.80 (3.03) g/10 min at 70 W to (5.2) g/ 10 min at 120 W using the 550 μm fibre. The total amount of ablated tissue using the 800 μm fibre was lower than with the 550 μm fibre. With increasing power output the bleeding rate remained stable in either group. Tissue penetration remained shallow, even with increasing power output. In contrast to H&E staining, where the coagulation zone was measured, NADH staining showed an inner zone of necrotic tissue, again with no difference between the 70- and the 120-W Tm-YAG. CONCLUSION The 120-W Tm-YAG offers significantly higher ablation rates than the 70-W device, and despite the increased rate of ablation with the 120-W Tm-YAG, the bleeding rate and depth of tissue penetration were comparable to those using the 70-W device. KEYWORDS benign prostatic enlargement, tissue ablation, coagulation, thulium : YAG, laser INTRODUCTION TURP and open simple prostatectomy are still considered the standard treatment for benign prostatic obstruction (BPO) by most urologists [1]. However, in recent years the laser treatment of BPO has been gaining increased acceptance, and various laser devices have been introduced to treat patients and thus achieve comparable operative results but decreased morbidity [2 4]. Despite increasing numbers of patients treated with laser-based techniques, a detailed scientific evaluation of the introduced laser devices is rare [5 7]. Ablation capacities, extent of coagulation and of the necrotic tissue zone needs to be determined to combine efficient treatment with the greatest safety possible for the patient. To compare and judge the possibilities and limitations of different laser systems, exvivo data need to be available. The purpose of the present ex-vivo study was to evaluate the ablative and coagulative capacities of the 120-W thulium:yttrium-aluminium-garnet (Tm-YAG) 2 μm continuous-wave laser under standardized experimental conditions and compare it to the previously introduced 70-W device. MATERIALS AND METHODS Laser ablation was performed using a 120-W 2 μm continuous-wave Tm-YAG laser (RevoLix TM, Lisa Laser Products, Katlenburg, Germany). Laser energy is emitted at μm in a continuous-wave mode. Output power levels of 70 and 120 W were used in the trial. For the delivery of laser energy flexible 550- and 800-μm optical-core bare-ended fibres were used in a contact mode to vaporize tissue. The model of an isolated blood-perfused porcine kidney was used to evaluate the tissue ablation capacity and the haemostatic properties, as previously described [8 10]. After catheterization of the renal artery and vein with a 10 F catheter, fresh porcine kidneys were perfused with 0.9% saline until the effluent was clear. Autologous blood was 2009 BJU INTERNATIONAL doi: /j x x 1

2 BACH ET AL. TABLE 1 The depth of coagulation zone and necrotic tissue layer Tm-YAG laser Mean (SD) variable, mm; bare-ended fibre, μm 70 W 120 W P * Coagulation zone (H&E staining) (0.02) 0.40 (0.04) (0.07) 0.39 (0.03) P Necrotic tissue layer, including coagulation zone (NADH) (0.14) 1.09 (0.24) (0.30) 1.06 (0.07) P FIG. 1. Histological findings after Tm:YAG vaporization of the porcine kidney (120 W). H&E staining ( 50) showing a superficial coagulation zone (yellow line). *Penetration depth with increasing power output; Penetration depth with increasing fibre diameter. harvested and anti-coagulated with sodium citrate. Trials were performed in an acryl basin containing 0.9% saline at 37 C. All experiments were carried out by the same surgeon. Four experiments were performed for each output power level and fibre, using one porcine kidney per measurement. Before commencing, each kidney was kept in the basin for 30 min to adapt to the temperature. To evaluate tissue ablation, the catheters in the renal artery and vein were removed, the vessels ligated and the capsule was removed. To determine the ablation capacity the kidneys were weighed before and after 10 min of laser treatment to a surface area of 3 3 cm. The weight difference was taken to be the amount of removed tissue. To achieve reproducible results, the laser fibre was moved in contact mode with a constant drag speed of 1 cm/min over the tissue. To evaluate the haemostatic properties of the laser devices the kidneys were perfused with autologous blood by a roller pump via the catheter in the renal artery. Blood was drained from the kidneys through the catheter in the renal vein to ensure a clear vision in the basin. The haemostatic properties of the laser devices were determined using the same generator power levels. The perfusion rate was set to 80 ml/min, resulting in a pressure of cmh 2 O. After removing the renal capsule, a surface area of 9 cm 2 (3 3 cm) was treated. The blood loss was quantified by the weight difference of a swab before and after it was placed on the bleeding surface for 60 s. Subsequently, samples of the ablated renal tissue were removed, cut on blocks and fixed in 4% formalin. After embedding in paraffin, the blocks were frozen at 19 C, sectioned and stained using haematoxylin and eosin (H&E) to measure the depth of the coagulation zone. To further evaluate cellular viability and the depth of necrotic tissue zone, NADH staining was also applied on tissue frozen at 80 C after fixation. The depth of coagulation and necrotic tissue zone induced by laser energy were determined by microscopy using a calibrated calliper. Specimen preparation and the assessment of the coagulation zone and necrotic zones were carried out by one examiner. Statistical data are presented as the mean (SD); the statistical significance of differences was evaluated using the Mann Whitney test, with P < 0.05 considered to indicate statistical significance. RESULTS The tissue ablation rate at a power output of 70 W was 9.80 (3.03) g/10 min when using the 550 μm fibre. Increasing the fibre diameter to 800 μm lead to less tissue ablation, of 6.38 (1.08) g/10 min. The amount of released laser energy was comparable in both groups, at (0.18) and (0.06) kj. Increasing the power output to 120 W increased the amount of ablated tissue to (5.2) g/10 min with the 550 μm fibre and to (2.8) g/10 min with the 800 μm fibre (P = 0.005). Again, the total amount of ablated tissue was less than with the 800 μm fibre than the 550 μm fibre. As before, the amount of delivered energy did not differ, at (0.05) vs (0.35) kj. The bleeding rate was unaffected by FIG. 2. Histological findings in NADH-stained cryosections ( 50) after Tm:YAG vaporization (120 W). The outer coagulation zone (yellow line) can be discriminated against the inner zone of necrotic tissue (red line) and the blue stained layer of viable tissue. increasing the energy output; using the 550 μm fibre the bleeding rate was 0.11 (0.03) g/min at 70 and 0.15 (0.09) g/min at 120 W (P = 0.413). Using the 800 μm fibre the bleeding rate was 0.17 (0.08) g/min at 70 and 0.14 (0.08) g/min at 120 W (P = 0.646). Likewise, there were no significant differences in bleeding rates between the 550 and the 800 μm fibres at settings of 70 (P = 0.289) or 120 W (P = 0.807). Histological examination of the extent of coagulation and the necrotic tissue zone are shown in Table 1; there was a stable penetration depth with increasing power output and increased fibre diameter. NADH staining confirmed the depth of the coagulation zone as measured by H&E staining (Fig. 1). However, using NADH, an inner zone of necrotic tissue underlying the coagulation zone could be identified (Fig. 2) BJU INTERNATIONAL

3 DISCUSSION Laser treatment for BPO is gaining widespread acceptance but currently several different laser systems are used for treating BPO. In addition to the holmium:yag and potassium titanyl phosphate (KTP)/lithium triborate (LBO) laser prostatectomy, innovative laser systems like the Tm-YAG have been introduced and are producing promising clinical data [11]. The initial data are also available using diode laser systems [3]. Due to different physical properties, e.g. the mode of energy emission and possible power outputs, comparisons of different lasers systems in terms of coagulation and ablation capacity, and more so the penetration depth, remain difficult. Therefore, not only clinical but also ex-vivo evaluation of the introduced laser systems is essential to understand the clinical outcome and possible complications, and to keep the risk of unwanted side-effects as low as possible. The Tm-YAG laser was introduced into the treatment of BPO with promising results [4], which have now been confirmed by others [12,13]. The first ex-vivo evaluation of the previously introduced 70-W Tm-YAG showed an ablative capacity greater than that of the KTP laser, with comparable low bleeding rates [6]. With the introduction of a high-power (120 W) Tm-YAG, a re-assessment of the ablative and haemostatic properties is obligatory. In particular, it needs to be clarified if the higher power could create a deeper zone of tissue coagulation and tissue penetration, which might lead to an increased risk of collateral damage. Our results show that the amount of tissue ablation increased with increased power output. Tissue ablation was lower with the 800 μm fibre, as laser energy is distributed over a larger surface area, leading to a lower energy density. However, independently of the fibre diameter, tissue ablation with the Tm- YAG seemed to be more effective than that reported in other systems. Wendt-Nordahl et al. [7] reported their results of tissue vaporization with a 120-W, 980-nm diode laser. Within an interval of 15 min, 10.6 g of renal tissue was vaporized, using a 600-μm optical-core fibre. This leads to a mean tissue ablation rate of 0.71 g/min, compared to rates of 1.64 and 1.29 g/min in the present study using the 550- and 800-μm fibres, respectively, at 120 W. Wendt-Nordahl et al. [14] also reported their experience of tissue ablation using bipolar plasma-kinetic vaporization and photoselective vaporization comparing the 80 W KTP laser with the 120 W LBO device. In this report the mean tissue vaporization rate was 0.95 g/min using plasma-kinetic vaporization, compared to 0.70 g/min with the 120-W LBO laser and 0.39 g/min with the 80-W KTP device, again showing lower ablation rates than with the Tm-YAG. However, the highest tissue ablation rate was with TURP; with a constant drag speed of 1 cm/s, a mean of 16.5 g/min of tissue was removed [7]. The clinical advantages of the laser devices are mostly the underlying reduced bleeding rates. Therefore, the data on bleeding rate and tissue coagulation zone seem more appealing. The present results indicate that in Tm-YAG laser vaporization the bleeding rate remains stable with increasing power output. The bleeding rate using the 550 μm fibre at 70 W and 120 W was 0.11 (0.03) and 0.15 (0.09) g/ min, respectively. This appears to be different from the KTP laser; as reported by Wendt- Nordahl et al. [14], the bleeding rate increased with higher power output, from 0.21 g/min in the 80 W KTP system to 0.65 g/min with the 120 W LBO device. Low bleeding rates are also reported in ex-vivo evaluations of different diode lasers, at g/min [5,7]. Compared to TURP, the bleeding rate is definitely lower in all laser systems, promising reduced intraoperative bleeding in the treatment of BPO. Bleeding rates in TURP are as high as g/min [7]. Whatever energy device is used to treat BPO, there is some thermal penetration of tissue, and coagulation artefacts and necrotic tissue layers are produced. Some of these artefacts are visible, as in surface carbonization or denaturation of haemoglobin, leading to a white surface [15]. More interestingly are the effects of energy in the deeper tissue layers, leading to a lower possibility of histological assessment, or even collateral damage if tissue penetration is high. Therefore, knowledge about this depth of tissue penetration is essential to estimate the risk of unintended collateral tissue damage. Using standard H&E staining, the coagulation zone extent with the 70-W Tm-YAG was as shallow as 0.36 mm with the 550-μm bare-ended fibre (0.49 mm/800 μm fibre), which is comparable to TURP (0.28 mm) and about half of that measured for the 80-W KTP laser (0.66 mm) [9], whereas data on the 120-W LBO device has yet to be reported. Interestingly, the coagulation zone is much deeper in the evaluated diode laser systems. Seitz et al. [5,16] reported total tissue coagulation rims of 9.56 mm (940 nm) to 10.2 mm (980 nm), using power settings of 60 and 100 W, respectively, in a similar ex-vivo kidney model. If and to what degree this deep penetration of tissue has an effect on the outcome of treatment for BPO remains to be evaluated in clinical studies. However, the depth of tissue penetration is undoubtedly a crucial factor in laser therapy of the lower urinary tract, and might be responsible for significant complications. Recently the first clinical follow-up data were presented by Rieken et al. [17], showing high reoperation rates of 32% within 12 months. Almost 20% of the patients had to undergo repeat surgery due to obstructive necrotic tissue. The authors suspected that deep tissue penetration was responsible for the high rate of necrotic tissue. The effect of heating does not end at the border of the coagulation zone. Due to the applied laser energy tissue is heated and vaporization occurs, and below this vaporization zone there is a coagulation layer. Furthermore, the tissue below this coagulation zone inevitable has some heat penetration, which might cause cellular damage. Seitz et al. [5] described these damage zones as an inner and outer layer of coagulated tissue. To further evaluate this effect, we used NADH staining to evaluate the histological effects of the Tm-YAG in the porcine kidney model; NADH staining is currently known to be the best means of determining cellular viability [18]. The present results confirm the findings of Seitz et al. [5] about the existence of an outer coagulation zone and an inner zone of tissue affected by laser energy (necrotic zone). NADH staining seems to have the potential to clearly identify these two layers of energy effects (Fig. 2). Due to the nature of this staining method, the measurement of the affected tissue area appears to be more investigator-independent. Nevertheless, invivo studies, especially on prostatic tissue, are needed to confirm these findings. Limitations of the study were centred on the animal model used, which provides a tool for the systematic evaluation of ablative devices [8 10]. Although the specific variables like heat capacity, thermal conductivity and diffusivity, optical tissue absorption and 2009 BJU INTERNATIONAL 3

4 BACH ET AL. scattering in the renal and prostatic tissue are very similar, the blood-perfused kidney does not resemble human prostatic tissue in every aspect [19]. Furthermore, any comparison between different laser devices and different studies must be analysed with care, as different environmental conditions or investigator-related variations might alter the measured results, e.g. tissue ablation. Especially the distance to the treated surface and fibre speed have significant effects on ablation capacities and are at risk of being influenced by investigator bias, which can lead to favourable results for one device over the other. Therefore, the results for ablative and haemostatic properties, and the coagulation zone of the devices, might be different when lasers are used in-vivo. Assuming bias-free measurement in the different published studies, the present model offers comparable conditions for every measurement, power output and wavelength to achieve a valid comparison. Although the ex-vivo results cannot be translated to a clinical effect without further investigation, the ex-vivo evaluation provides relevant information on possible limitations and risks of the tested energy devices. In our study there was an effective ablation and shallow coagulation zone with increased energy output, leading to the conclusion that increased power of the Tm-YAG laser should not lead to unwanted energy-related complications in the clinical setting. In conclusion, in an ex-vivo setting, the increasing energy output of the 2-μm continuous-wave Tm-YAG laser from 70 to 120 W leads to an increased rate of tissue ablation with no apparent increase in bleeding rate or tissue penetration. Although awaiting clinical verification of the 120-W device, these results promise high treatment efficacy with a considerably decreased risk of bleeding. CONFLICT OF INTEREST None declared. REFERENCES 1 Madersbacher S, Marberger M. Is transurethral resection of the prostate still justified? BJU Int 1999; 83: Kuntz RM. Current roles of lasers in the treatment of benign prostatic hyperplasia (BPH). Eur Urol 2006; 49: Seitz M, Sroka R, Gratzke C et al. The diode laser: a novel side-firing approach for laser vaporisation of the human prostate immediate efficacy and 1-year follow-up. Eur Urol 2007; 52: Bach T, Herrmann TR, Ganzer R et al. RevoLix vaporesection of the prostate: initial results of 54 patients with a 1-year follow-up. World J Urol 2007; 25: Seitz M, Bayer T, Ruszat R et al. Preliminary evaluation of a novel side-fire diode laser emitting light at 940 nm, for the potential treatment of benign prostatic hyperplasia: ex-vivo and in-vivo investigations. BJU Int 2009; 103: Wendt-Nordahl G, Huckele S, Honeck P et al. Systemic evaluation of a recently introduced 2-μm continuous wave thulium laser for vaporesection of the prostate. J Endourol 2008; 22: Wendt-Nordahl G, Huckele S, Honeck P et al. 980-nm diode laser. A novel laser technology for vaporization of the prostate. Eur Urol 2007; 52: Reich O, Bachmann A, Schneede P, Zaak D, Sulser T, Hofstetter A. Experimental comparison of high power (80 W) potassium titanyl phosphate laser vaporization and transurethral resection of the prostate. J Urol 2004; 171: Wendt-Nordahl G, Häcker A, Fastenmeier K et al. New bipolar resection device for transurethral resection of the prostate: first ex-vivo and in-vivo evaluation. J Endourol 2005; 19: Michel MS, Köhrmann KU, Weber A, Krautschick AW, Alken P. Rotoresect: new technique for resection of the prostate: experimental phase. J Endourol 1996; 10: Bach T, Herrmann TRW, Haecker A, Michel MS, Gross AJ. Thulium: yttriumaluminium-garnet laser prostatectomy in men with refractory urinary retention. BJU Int 2009; 104: Xia SJ, Zhuo J, Sun XW, Han BM, Shao Y, Zhang YN. Thulium laser versus standard transurethral resection of the prostate: a randomized prospective trial. Eur Urol 2008; 53: Szlauer R, Götschl R, Razmaria A, Paras L, Schmeller NT. Endoscopic vaporesection of the prostate using the continuous-wave 2-μm thulium laser: outcome and demonstration of the surgical technique. Eur Urol 2009; 55: Wendt-Nordahl G, von Löwenstern K, Honeck P et al. Ex-vivo comparison of bipolar plasma-kinetic vaporization of the prostate to low power and high power Greenlight laser. J Endourol 2008; 22 (Suppl. 1): A19, BR Bach T, Herrmann TRW, Cellarius C, Gross AJ. Bladder neck incision using a 70 W 2 micron continuous wave laser (RevoLix). World J Urol 2007; 25: Seitz M, Ackermann A, Gratzke C et al. Diode laser. Ex vivo studies on vaporization and coagulation characteristics. Urologe A 2007; 46: Rieken M, Wyler S, Müller G, Bonkat G, Gasser T, Bachmann A. Laser vaporization of the prostate: intermediate-term follow-up with the 200W high-intensity diode (HiDi) laser system. Eur Urol Suppl 2009; 8: 268; Abstract Anderson JK, Baker M, Jaffers O, Pearle MS, Lindberg GL, Cadeddu JA. Time course of nicotinamide adenine dinucleotide diaphorase staining after renal radiofrequency ablation influences viability assessment. J Endourol 2007; 21: Cooper TE, Trezek GJ. A probe technique for determining the thermal conductivity of tissue. J Heat Transfer 1972; 94: Correspondence: Thorsten Bach, Department of Urology, University Centre Mannheim, Theodor-Kutzer-Ufer 1-3, Mannheim, Germany. thorsten.bach@umm.de Abbreviations: BPO, benign prostatic obstruction; Tm-YAG, thulium:yttriumaluminium-garnet; H&E, haematoxylin and eosin; KTP, potassium titanyl phosphate; LBO, lithium triborate. EDITORIAL COMMENT Ex-vivo models to assess comparative tissue vaporization efficiencies of various laser technologies need to be examined with a clear caveat that bias in technique can interfere with the outcome, and be misleading. This can occur despite the best intentions of the investigators, as these models do not mimic conditions during real clinical scenarios. The present model is particularly unsuited for comparing high power 532 nm, 980 nm, Nd/ BJU INTERNATIONAL

5 YAG, holmium and thulium systems with each other, as the optimum parameters for each in this model might not reflect the optimum efficiencies obtained in the clinical setting. For example, the high-power 532 nm wavelength selectively uses oxyhaemoglobin as the main chromophore, with little absorption of power by the irrigating aqueous medium. This means that most of the power is absorbed in the target tissue, with potential local conductive heating if there is no local method to remove the heat, e.g. blood perfusion or cooling irrigating fluid. In the ex-vivo model, the deep coagulation necrosis is caused by the local high conductive heat that is produced from the effective and highly laser-absorbent resulting hot tissue that has been treated with the 532 nm laser light. There is deep coagulation necrosis despite the shallow optical penetration depth in the model. In the clinical setting, this is limited by quick sweeps, good aqueous irrigation cooling the tissue, and actual perfusion of the tissue by its blood supply, removing the heat. This important technical concept is termed thermal confinement, and it is important to maintain it during clinical practice, to limit the unwanted side-result of deep coagulation necrosis, resulting in prolonged dysuria, tissue sloughing, and oedema causing retention. In this ex-vivo model, fixed parameters for one technology might not be optimized for another, and thus comparative evaluations are basically placed into question as to validity, and can be misleading. For example, if the same power, sweep speed and distance, irrigating and perfusion qualities are used with the high-power 532 nm laser vs the 980 nm laser, there would be less power absorbed into the tissue by the 980 nm laser because about half the energy is absorbed by the aqueous medium between the tissue and the laser fibre. Also, as the optical penetration depth is greater, the laser light would cause deep heating effects produced primarily by the laser light. In theory, given the same scenario and technique, deeper coagulation necrosis would result. As such, each laser system and wavelength requires a different technique to optimize their outcomes. Using the 532-nm technique with 980-nm lasers will not produce the same outcomes. This particular study is excellent as it focuses only on one wavelength to compare and contrast with power as the main differentiator. The results are not surprising given the laser characteristic of the Tm:YAG laser for this model. However, as the primary chromophore is water with this laser, the primary mechanism of action is the hot vaporizing quasi-continuous bubbles produce by the laser on contact to near-contact. That being stated, it is impressive that such a mechanism of action is so efficient in ablating tissue. Hopefully, this will translate effectively in the clinical setting. Alexis Te Urology, Weill Medical College of Cornell University and New York Presbyterian Hospital, New York, NY, USA 2009 BJU INTERNATIONAL 5

TURP-like results with fewer complications and less morbidity than TURP 6,7

TURP-like results with fewer complications and less morbidity than TURP 6,7 TURP-like results with fewer complications and less morbidity than TURP 6,7 Lower Morbidity Proven Equivalent to turp with Lower overall cost 8 6,7 Fewer Complications Shorter Hospital Stays 6,7 A world

More information

Sphinx COMPETENCE IN SURGICAL LASER SINCE 1989 HOLMIUM LASER LASER TECHNOLOGY - MADE IN GERMANY

Sphinx COMPETENCE IN SURGICAL LASER SINCE 1989 HOLMIUM LASER LASER TECHNOLOGY - MADE IN GERMANY Sphinx HOLMIUM LASER Versatile Holmium laser for Urology, Spine and ENT COMPETENCE IN SURGICAL LASER SINCE 1989 LASER TECHNOLOGY - MADE IN GERMANY WWW.LISALASER.DE WHY SPHINX Absorption Coefficient [cm

More information

Loss of Power Output and Laser Fibre Degradation during 120 Watt Lithium-Triborate HPS Laser Vaporisation of the Prostate.

Loss of Power Output and Laser Fibre Degradation during 120 Watt Lithium-Triborate HPS Laser Vaporisation of the Prostate. Loss of Power Output and Laser Fibre Degradation during 120 Watt Lithium-Triborate HPS Laser Vaporisation of the Prostate. Thomas Hermanns a, Tullio Sulser a, Lukas J. Hefermehl a, Daniel Strebel a, Maurice-Stephan

More information

Sphinx. Holmium Laser. Versatile Holmium laser for Minimally Invasive Surgery in Urology, Spine, Arthroscopy and ENT

Sphinx. Holmium Laser. Versatile Holmium laser for Minimally Invasive Surgery in Urology, Spine, Arthroscopy and ENT Sphinx Holmium Laser Versatile Holmium laser for Minimally Invasive Surgery in Urology, Spine, Arthroscopy and ENT THE COMPANY WHY HOLMIUM Holmium Sphinx - why Holmium? The versatile Two Micron laser Strong

More information

Holmium laser prostatectomy

Holmium laser prostatectomy NHS National Institute for Clinical Excellence Holmium laser prostatectomy Understanding NICE guidance information for men considering the procedure, and for the public November 2003 Holmium laser prostatectomy

More information

HOLMIUM LASER HL-3000

HOLMIUM LASER HL-3000 Turnkey Laboratories Solutions HL-3000 Main Application Fields UROLOGY GENERAL SURGERY ENT EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited

More information

Sphinx. Holmium Laser. Versatile Holmium laser for Minimally Invasive Surgery in Urology, Spine, Arthroscopy and ENT

Sphinx. Holmium Laser. Versatile Holmium laser for Minimally Invasive Surgery in Urology, Spine, Arthroscopy and ENT Sphinx Holmium Laser Versatile Holmium laser for Minimally Invasive Surgery in Urology, Spine, Arthroscopy and ENT THE COMPANY WHY HOLMIUM Holmium Sphinx - why Holmium? The versatile Two Micron laser Strong

More information

Sphinx LISALASERPRODUCTS LISALASERPRODUCTSLISALASERPRODUCTSLISALASERPRODUCTSLISALASERPRODUCTS. Holmium-YAG Laser System. Versatile Holmium laser

Sphinx LISALASERPRODUCTS LISALASERPRODUCTSLISALASERPRODUCTSLISALASERPRODUCTSLISALASERPRODUCTS. Holmium-YAG Laser System. Versatile Holmium laser Sphinx System LISALASERPRODUCTSLISALASERPRODUCTSLISALASERPRODUCTSLISALASERPRODUCTS Versatile Holmium laser for Minimally invasive surgery in Urology, Spine, Arthroscopy and ENT LISALASERPRODUCTS WHY HOLMIUM

More information

ESWL AND LASER ESWL AND LASER

ESWL AND LASER ESWL AND LASER ESWL AND LASER ESWL AND LASER ESWL ESWL is abbreviation for د. ھدي ن Extracarporeal Shock Wave Lithotripsy. Is a minimally invasive exposes patients to less anesthesia, and yields equivalent stone-free

More information

vela QI The 1.9µm desktop thulium laser Precision and fl exibility redefi ned Next generation surgical cutting

vela QI The 1.9µm desktop thulium laser Precision and fl exibility redefi ned Next generation surgical cutting vela QI The 1.9µm desktop thulium laser Precision and fl exibility redefi ned Next generation surgical cutting About StarMedTec Our goal is to meet the demands of physicians for efficient surgical lasers

More information

Lase smarter. MEDICAL

Lase smarter. MEDICAL Lase smarter. MEDICAL Dust or bust. The Rhapsody H-30 Holmium Laser System has a variable pulse width that enables you to tailor your treatment on the fly. The short pulse is recommended for breaking apart

More information

W A T E R J E T S U R G E R Y. A new Dimension in Waterjet Surgery:

W A T E R J E T S U R G E R Y. A new Dimension in Waterjet Surgery: W A T E R J E T S U R G E R Y E r b E J E T 2 A new Dimension in Waterjet Surgery: The ERBEJET 2 in the VIO System. Waterjet Surgery A Sparing Oper ative Procedure. Biological tissue such as organs, connective

More information

Holmium laser: YAG lithotripsy in ureteral calculi management

Holmium laser: YAG lithotripsy in ureteral calculi management Journal of Physics: Conference Series PAPER OPEN ACCESS Holmium laser: YAG lithotripsy in ureteral calculi management To cite this article: J Sunaryo et al 2018 J. Phys.: Conf. Ser. 1073 062052 View the

More information

CASE REPORTS: Zero Ischemia Robotic Laser Partial Nephrectomy: Use of the Thulium laser in Renal Cell Carcinoma

CASE REPORTS: Zero Ischemia Robotic Laser Partial Nephrectomy: Use of the Thulium laser in Renal Cell Carcinoma CASE REPORTS: Zero Ischemia Robotic Laser Partial Nephrectomy: Use of the Thulium laser in Renal Cell Carcinoma We present a technique for zero-ischemia robotic laser partial nephrectomy, which addresses

More information

Morphological Comparison of Blood Vessels that were Heated with a Radiofrequency Device or a 1470-nm Laser and a Radial 2Ring Fiber

Morphological Comparison of Blood Vessels that were Heated with a Radiofrequency Device or a 1470-nm Laser and a Radial 2Ring Fiber Ann Vasc Dis Vol. 9, No. 4; 2016; pp 272 276 Online December 1, 2016 2016 Annals of Vascular Diseases doi:10.3400/avd.oa.16-00120 Original Article Morphological Comparison of Blood Vessels that were Heated

More information

The neov endovascular

The neov endovascular www.neo-laser.com The neov endovascular Surgical power was never so small The neov1470 surgical laser the smallest, lightest weight, and most portable laser system of its power class. DESIGNED FOR SURGERY

More information

LASER: The Light That Heals

LASER: The Light That Heals LASER: The Light That Heals By Farouk A.H. Al-Watban, MSc, PhD, FASLMS King Faisal Specialist Hospital & Research Centre Riyadh, Kingdom of Saudi Arabia The instant images that leap to one s mind at the

More information

ABSTRACT 1. INTRODUCTION 2. TRADITIONAL RADIOFREQUENCY GENERATOR POWER DELIVERY

ABSTRACT 1. INTRODUCTION 2. TRADITIONAL RADIOFREQUENCY GENERATOR POWER DELIVERY A simplified, low power system for effective vessel sealing Allison B. Lyle, Jenifer S. Kennedy, Dale F. Schmaltz, Aaron S. Kennedy JustRight Surgical, LLC, 6325 Gunpark Drive, Ste G, Boulder, CO 80301

More information

European Urology ) 312±317

European Urology ) 312±317 European Urology European Urology 41 2002) 312±317 Flexible Ureterorenoscopy for the Treatment of Lower Pole Calyx Stones: In uence of Different Lithotripsy Probes and Stone Extraction Tools on Scope De

More information

Dornier Medilas D MultiBeam

Dornier Medilas D MultiBeam Dornier Medilas D MultiBeam W E R E A L L A B O U T P E O P L E. Dornier Medilas D MultiBeam The Dornier Medilas D MultiBeam is a compact, multi-functional diode laser capable of performing surgical, minimally

More information

The neov endovascular

The neov endovascular The neov endovascular Surgical power was never so small The neov surgical laser platform with your choice of 1470 nm or 980 nm - The smallest, lightest weight, and most portable laser system of its power

More information

Comparison between a 1.92-μm fiber laser and a standard HF-dissection device for nephron-sparing kidney resection in a porcine in vivo study

Comparison between a 1.92-μm fiber laser and a standard HF-dissection device for nephron-sparing kidney resection in a porcine in vivo study DOI 10.1007/s10103-010-0873-y ORIGINAL ARTICLE Comparison between a 1.92-μm fiber laser and a standard HF-dissection device for nephron-sparing kidney resection in a porcine in vivo study Dirk Theisen-Kunde

More information

POTASSIUM-TITANYL-PHOSPHATE LASER LAPAROSCOPIC PARTIAL NEPHRECTOMY WITHOUT HILAR CLAMPING IN THE SURVIVAL CALF MODEL

POTASSIUM-TITANYL-PHOSPHATE LASER LAPAROSCOPIC PARTIAL NEPHRECTOMY WITHOUT HILAR CLAMPING IN THE SURVIVAL CALF MODEL 0022-5347/05/1743-1110/0 Vol. 174, 1110 1114, September 2005 THE JOURNAL OF UROLOGY Printed in U.S.A. Copyright 2005 by AMERICAN UROLOGICAL ASSOCIATION DOI: 10.1097/01.ju.0000168620.36893.6c POTASSIUM-TITANYL-PHOSPHATE

More information

Minimally invasive laser therapy of BPH and tumors

Minimally invasive laser therapy of BPH and tumors twister xcavator Minimally invasive laser therapy of BPH and tumors Excellent hemostasis Fast and efficient prostate ablation Tolerated with high risk patient Local or minimal anesthesia BPH Benigne Prostatic

More information

Minimally invasive laser therapy of BPH and tumors

Minimally invasive laser therapy of BPH and tumors twister xcavator Minimally invasive laser therapy of BPH and tumors Excellent hemostasis Fast and efficient prostate ablation Tolerated with high risk patient Local or minimal anesthesia BPH Benigne Prostatic

More information

Page 2 of 9 Anatomy of a laser The lasing medium exists between 2 mirrors for light amplification to occur; one is fully reflective and the other only

Page 2 of 9 Anatomy of a laser The lasing medium exists between 2 mirrors for light amplification to occur; one is fully reflective and the other only Page 1 of 9 Medscape Reference Reference News Reference Education MEDLINE Lasers in Urology Author: Michael Grasso III, MD; Chief Editor: Bradley Fields Schwartz, DO, FACS more... Updated: Aug 3, 2011

More information

Cyber Ho. Taking care of people, our masterpieces. High Power Holmium Surgical Laser System. Surgery

Cyber Ho. Taking care of people, our masterpieces. High Power Holmium Surgical Laser System. Surgery Taking care of people, our masterpieces Cyber Ho High Power Holmium Surgical Laser System This brochure is not intended for the U.S. market. Certain Intended Uses/Configurations/Models/Accessories are

More information

ENHANCED PERFORMANCE SWISS LASERCLAST

ENHANCED PERFORMANCE SWISS LASERCLAST ENHANCED PERFORMANCE LASERCLAST LASERCLAST LASERCLAST THE SYSTEM THE SYSTEM LASERCLAST 20W VERSATILE HOLMIUM:YAG LASER, OPTIMUM ENERGY AND PULSE DURATION } EFFECTIVE STONE AND SOFT-TISSUE TREATMENTS }

More information

Dornier Medilas D FlexiPulse

Dornier Medilas D FlexiPulse Dornier Medilas D FlexiPulse W E R E A L L A B O U T P E O P L E. Dornier Medilas D FlexiPulse The Dornier Medilas D FlexiPulse is a compact, high powered diode laser capable of performing a variety of

More information

Positive surgical margins in partial nephrectomy specimens: Urologist view. Ofer Nativ MD

Positive surgical margins in partial nephrectomy specimens: Urologist view. Ofer Nativ MD Positive surgical margins in partial nephrectomy specimens: Urologist view Ofer Nativ MD Financial and Other Disclosures Off-label use of drugs, devices, or other agents: None or FILL IN HERE; including

More information

Endoscopic Enucleation and Morcellation from KARL STORZ

Endoscopic Enucleation and Morcellation from KARL STORZ URO 52 10/2017-E Endoscopic Enucleation and Morcellation from KARL STORZ All from a single source Endoscopic Enucleation of the Prostate (EEP) Instruments for all endoscopic enucleation techniques everything

More information

Chapter 8. Comparison of static vs dynamic culture

Chapter 8. Comparison of static vs dynamic culture Chapter 8 Comparison of static vs dynamic culture 8.1. Literature Review Articular cartilage is a load-bearing connective tissue in which its functions not only transmitting the compressive joint loads

More information

PREPARATION OF HISTOLOGICAL SPECIMENS

PREPARATION OF HISTOLOGICAL SPECIMENS PREPARATION OF HISTOLOGICAL SPECIMENS Histo-techniques Preparation of tissue for microscopic examination Series of processes Ultimate aim to make tissue visible as it is Pathology Vs Anatomy Steps vary

More information

The Power of Three. The Simplicity of One.

The Power of Three. The Simplicity of One. The Power of Three. The Simplicity of One. Finally, an energy device that you don t have to set down. The new J-Plasma handpieces with Cool-Coag technology deliver the precision of helium plasma energy,

More information

The Power of Three. The Simplicity of One.

The Power of Three. The Simplicity of One. The Power of Three. The Simplicity of One. Finally, an energy device that you don t have to set down. The new J-Plasma handpieces with Cool-Coag technology deliver the precision of helium plasma energy,

More information

Application manual for the C-LAS laser wavelength 10,600 nm

Application manual for the C-LAS laser wavelength 10,600 nm ENT, Surgery, Aesthetics Application manual for the C-LAS laser wavelength 10,600 nm Bessemerstr. 14 90411 Nürnberg phone: +49.911.21779-0 fax: +49.911.21779-99 info@arclaser.de www.arclaser.de WARNING

More information

DA VINCI Xi SINGLE-SITE TECHNOLOGY SOLUTIONS FOR SINGLE-INCISION SURGERY

DA VINCI Xi SINGLE-SITE TECHNOLOGY SOLUTIONS FOR SINGLE-INCISION SURGERY DA VINCI Xi SINGLE-SITE SOLUTIONS FOR SINGLE-INCISION SURGERY TECHNOLOGY DA VINCI Xi SINGLE-SITE TECHNOLOGY AT INTUITIVE SURGICAL, WE STRIVE TO MAKE SURGERY MORE EFFECTIVE, LESS INVASIVE, AND EASIER ON

More information

Preparation of tissues for study

Preparation of tissues for study Preparation of tissues for study HISTOLOGY : It is the branch of science which deals with the microscopic study of normal tissue HISTOPATHOLOGY : It is the branch of science which deals with the microscopic

More information

The Power of Three. The Simplicity of One.

The Power of Three. The Simplicity of One. The Power of Three. The Simplicity of One. Finally, an energy device that you don t have to set down. The new J-Plasma handpieces with Cool-Coag TM technology deliver the precision of helium plasma energy,

More information

Pixel CO2 for ENT Procedures THE POWER OF. Precision

Pixel CO2 for ENT Procedures THE POWER OF. Precision Pixel CO2 for ENT Procedures THE POWER OF Precision Laryngology Bronchoscopy Phrenology Snoring Tonsillectomy Oral Surgery Otology Turbinectomy Nasal Cavity Head & Neck ENTelligence brings unparalleled

More information

VAPR TRIPOLAR 90 Suction Electrode with COOLPULSE Technology VALUE ANALYSIS BRIEF

VAPR TRIPOLAR 90 Suction Electrode with COOLPULSE Technology VALUE ANALYSIS BRIEF VAPR TRIPOLAR 90 Suction Electrode with COOLPULSE Technology VALUE ANALYSIS BRIEF Introduction and Methodology This value analysis brief presents information on the design features and potential procedural

More information

HISTOPATHOLOGY INTRODUCTION

HISTOPATHOLOGY INTRODUCTION HISTOPATHOLOGY INTRODUCTION Surgical, anatomical and consultative pathology services are available through pathologists in the Department of Pathology. The services available include: Routine surgical

More information

Introducing the Fraxel DUAL 1550/1927 System

Introducing the Fraxel DUAL 1550/1927 System Introducing the Fraxel DUAL 1550/1927 System Deliver superior results with less downtime than a superficial ablative treatment We ve taken the industry leading non-ablative Fraxel re:store system to the

More information

Polidocanol Endovenous Microfoam (PEM) Comprehensive Treatment for Great Saphenous Vein System (GSV) Incompetence

Polidocanol Endovenous Microfoam (PEM) Comprehensive Treatment for Great Saphenous Vein System (GSV) Incompetence Polidocanol Endovenous Microfoam (PEM) Comprehensive Treatment for Great Saphenous Vein System (GSV) Incompetence By Ariel D. Soffer, MD, FACC Dr. Ariel David Soffer-Bio NCVH Vein Forum Fellow of the American

More information

Type of intervention Treatment. Economic study type Cost-effectiveness analysis.

Type of intervention Treatment. Economic study type Cost-effectiveness analysis. Laparoscopic vs open nephrectomy in 210 consecutive patients: outcomes, cost, and changes in practice patterns Kercher K W, Heniford B T, Matthews B D, Smith T I, Lincourt A E, Hayes D H, Eskind L B, Irby

More information

Introduction. History of Robotic system. What is Robot in Medicine? The Edge and Limitations in Robotic Surgery in a Public System

Introduction. History of Robotic system. What is Robot in Medicine? The Edge and Limitations in Robotic Surgery in a Public System Introduction The Edge and Limitations in Robotic Surgery in a Public System Dr Anthony Chi-Fai NG Associate Professor Division of Urology Department of Surgery The Chinese University of Hong Kong What

More information

Transferring biomedical research to patients DR GIUSEPPE RUVIO, NATIONAL UNIVERSITY OF IRELAND GALWAY

Transferring biomedical research to patients DR GIUSEPPE RUVIO, NATIONAL UNIVERSITY OF IRELAND GALWAY Transferring biomedical research to patients DR GIUSEPPE RUVIO, NATIONAL UNIVERSITY OF IRELAND GALWAY Biodesign The Process of Innovating Medical Technologies Stefanos Zenios, Josh Makower, Paul Yock Overview

More information

(12) Patent Application Publication (10) Pub. No.: US 2011/ A1

(12) Patent Application Publication (10) Pub. No.: US 2011/ A1 (19) United States US 20110224660A1 (12) Patent Application Publication (10) Pub. No.: US 2011/0224660 A1 Neuberger et al. (43) Pub. Date: (54) DIODE LASER INDUCED VAPOR/PLASMA MEDIATED MEDICAL PROCEDURES

More information

An investigation into thermal necrosis of bone associated with surgical procedures

An investigation into thermal necrosis of bone associated with surgical procedures Modelling in Medicine and Biology VI 479 An investigation into thermal necrosis of bone associated with surgical procedures G. Pearce 1,3, C. Bainbridge 2, J. Patrick 3, K., Kibble 1, M. Lenz 1 & G. Jones

More information

UNIQUE HYBRID TECHNOLOGY. DOUBLE YOUR ENERGY THUNDERBEAT Type S Next Generation of Safety and Speed

UNIQUE HYBRID TECHNOLOGY. DOUBLE YOUR ENERGY THUNDERBEAT Type S Next Generation of Safety and Speed UNIQUE HYBRID TECHNOLOGY DOUBLE YOUR ENERGY THUNDERBEAT Type S Next Generation of Safety and Speed 15149 1 UNIQUE HYBRID TECHNOLOGY ADVANCED HEMOSTASIS Philosophy Olympus aims to provide innovative energy

More information

Example SimphoSOFT simulation of Thulium-Ion-Doped Pulsed Amplification

Example SimphoSOFT simulation of Thulium-Ion-Doped Pulsed Amplification Rare-earth ions can undergo fluorescence, cross-relaxation (or self-quenching), upconversion, and other non-radiative relaxations. For rare-earth ions, these processes are important for lasers, optical

More information

fiberguide Hard Clad Silica (Low OH) Fiberguide Industries Technical Data Anhydroguide APCH

fiberguide Hard Clad Silica (Low OH) Fiberguide Industries Technical Data Anhydroguide APCH DESCRIPTION With numerical aperture (N.A.) of 0.39 and a hard polymer cladding that allows a high core-to-clad ratio, the is the low cost fiber of choice. The pure fused silica (SiO 2 ) used in the core

More information

TECH EVIDENCE REPORT. A Performance Comparison Between Reprocessed and New Covidien LigaSure 5mm Blunt Tip Laparoscopic Sealer/Divider (1637)

TECH EVIDENCE REPORT. A Performance Comparison Between Reprocessed and New Covidien LigaSure 5mm Blunt Tip Laparoscopic Sealer/Divider (1637) TECH EVIDENCE REPORT A Performance Comparison Between Reprocessed and New Covidien LigaSure 5mm Blunt Tip Laparoscopic Sealer/Divider (1637) TECH EVIDENCE REPORT INTRODUCING THE REPROCESSED LIGASURE 5mm

More information

Teleflex Incorporated (NYSE: TFX) Investor Presentation

Teleflex Incorporated (NYSE: TFX) Investor Presentation Teleflex Incorporated (NYSE: TFX) Investor Presentation Important Information 2 Forward Looking Statements This presentation and our discussion contain forward-looking information and statements, which

More information

The Future of Radiofrequency Ablation is Looking BETA

The Future of Radiofrequency Ablation is Looking BETA The Future of Radiofrequency Ablation is Looking BETA Short and Long Term Studies of Bimodal Electric Tissue Ablation (BETA) in a Porcine Model Thesis submitted December, 2007 to The University of Adelaide

More information

Soft Tissue Puncture Model for Situation Awareness Percutaneous Robot

Soft Tissue Puncture Model for Situation Awareness Percutaneous Robot Soft Tissue Puncture Model for Situation Awareness Percutaneous Robot Inko ELGEZUA FERNANDEZ 2013 11 It is not a surprise that minimally invasive (MI) treatments have generated a great interest in surgeons

More information

LASER THERAPY - GENERAL INFORMATION

LASER THERAPY - GENERAL INFORMATION LASER THERAPY - GENERAL INFORMATION History In the past several years, some excellent experimental work has been performed and medical treatments with laser photo-therapy have passed through its infancy,

More information

Lasers service a diverse range of biomedical

Lasers service a diverse range of biomedical Meet Trends in Therapeutics Biomedical lasers are experiencing strong growth, with a move toward diode and fiber lasers. Current trends in biomedical laser therapeutics are characterizing the dynamic nature

More information

A New Dimension in Water Jet Surgery:

A New Dimension in Water Jet Surgery: w a t e r j e t s u r g e r y E r b E J E T 2 A New Dimension in Water Jet Surgery: The ERBEJET 2 in the VIO System. Perfection for Life Water Jet Surgery A Sparing Operative Procedure. Biological tissue

More information

ESSENTIAL ENERGY FOR PROVEN PATIENT OUTCOMES

ESSENTIAL ENERGY FOR PROVEN PATIENT OUTCOMES ESSENTIAL ENERGY FOR PROVEN PATIENT OUTCOMES LigaSure Curved Jaw Device GRASP. SEAL. AND CUT. WITH ONE DEVICE. Let s move beyond mechanical ligation to a higher level of performance in open surgery The

More information

Translational Multimodality Optical Imaging

Translational Multimodality Optical Imaging Translational Multimodality Optical Imaging Fred S. Azar Xavier Intes Editors 0 ARTECH H O U S E BOSTON LONDON artechhouse.com Contents Foreword Preface xv xvii CHAPTER1 Introduction to Clinical Optical

More information

Section 8. To introduce the basic theory and principles of collecting blood for Intraoperative Cell Salvage (ICS)

Section 8. To introduce the basic theory and principles of collecting blood for Intraoperative Cell Salvage (ICS) Section 8 Practicalities Blood Collection Aim To introduce the basic theory and principles of collecting blood for Intraoperative Cell Salvage (ICS) Learning Outcomes To identify the equipment used for

More information

Supplementary Materials and Methods:

Supplementary Materials and Methods: Supplementary Materials and Methods: Preclinical chemoprevention experimental design Mice were weighed and each mammary tumor was manually palpated and measured with digital calipers once a week from 4

More information

THE USE OF A DIODE LASER IN THE TREATMENT OF HEMORRHOIDAL DISEASE

THE USE OF A DIODE LASER IN THE TREATMENT OF HEMORRHOIDAL DISEASE International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 11, November 2018, pp. 2108 2112, Article ID: IJCIET_09_11_206 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=11

More information

Photoacoustic Imaging in Biomedicine Critical Review by Saurabh Vyas Group 9: Interventional Photoacoustic Ultrasound CIS II: 600.

Photoacoustic Imaging in Biomedicine Critical Review by Saurabh Vyas Group 9: Interventional Photoacoustic Ultrasound CIS II: 600. Photoacoustic Imaging in Biomedicine Critical Review by Saurabh Vyas Group 9: Interventional Photoacoustic Ultrasound CIS II: 600.446, Spring 2011 Introduction Photoacoustic imaging (PA Imaging) is the

More information

Minimization of thermomechanical side effects and increase of ablation efficiency in IR ablation by use of multiply Q-switched laser pulses

Minimization of thermomechanical side effects and increase of ablation efficiency in IR ablation by use of multiply Q-switched laser pulses Minimization of thermomechanical side effects and increase of ablation efficiency in IR ablation by use of multiply Q-switched laser pulses Alfred Vogel, Peter Schmidt, and Barbara Flucke Medizinisches

More information

Type of intervention Treatment; secondary prevention. Economic study type Cost-effectiveness analysis.

Type of intervention Treatment; secondary prevention. Economic study type Cost-effectiveness analysis. Coagulation disorders induced by L-asparaginase: correction with and without fresh-frozen plasma Glasmacher A, Kleinschmidt R, Unkrig C, Mezger J, Scharf R E Record Status This is a critical abstract of

More information

NONTRADITIONAL MANUFACTURING PROCESSES

NONTRADITIONAL MANUFACTURING PROCESSES NONTRADITIONAL MANUFACTURING PROCESSES Lasers & Laser Beam Machining Basic NTM Process Groups: * Thermal NTM Processes - Laser Beam Machining (LBM) - Electron Beam Machining (EBM) - Plasma Arc Machining

More information

Today we are going to talk about principles of electrosurgery. Electrosurgery came in to wide use because of the need to control bleeding during

Today we are going to talk about principles of electrosurgery. Electrosurgery came in to wide use because of the need to control bleeding during Today we are going to talk about principles of electrosurgery. Electrosurgery came in to wide use because of the need to control bleeding during operative procedures. 1 Surgeons have used electrical energy

More information

Control Your Energy. with the Right Settings. A guide to monopolar energy with the ERBE VIO dv. PN US Rev A 04/17

Control Your Energy. with the Right Settings. A guide to monopolar energy with the ERBE VIO dv. PN US Rev A 04/17 Control Your Energy with the Right Settings A guide to monopolar energy with the ERBE VIO dv A Versatile Energy Source at your fingertips The VIO dv generator offers a variety of monopolar settings so

More information

PTH Effects Bone Healing and Vasculogenesis in Calvaria Bone Allograft Model

PTH Effects Bone Healing and Vasculogenesis in Calvaria Bone Allograft Model PTH Effects Bone Healing and Vasculogenesis in Calvaria Bone Allograft Model Dmitriy Sheyn, PhD 1, Doron Cohn-Yakubovich, BSc 2, Ilan Kallai, MSc 2, Susan Su, MD 1, Xiaoyu Da, MSc 1, Gadi Pelled, DMD,

More information

National Institute for Health and Clinical Excellence. IP244/4 Ultrasound-guided foam sclerotherapy for varicose veins. Consultation Comments table

National Institute for Health and Clinical Excellence. IP244/4 Ultrasound-guided foam sclerotherapy for varicose veins. Consultation Comments table National Institute for Health and Clinical Excellence IP244/4 Ultrasound-guided foam sclerotherapy for varicose veins Consultation Comments table IPAC date: 13 December 2012 Com. 1 Consultee 1 2 Consultee

More information

Real-Time Detection Of Multiple Lesions During High Intensity Focused Ultrasound (HIFU) Treatments

Real-Time Detection Of Multiple Lesions During High Intensity Focused Ultrasound (HIFU) Treatments International Symposium on Therapeutic Ultrasound, Seattle, 2002. Real-Time Detection Of Multiple Lesions During High Intensity Focused Ultrasound (HIFU) Treatments Ralf Seip 1, Jahangir Tavakkoli 1, Adam

More information

For In Vitro Diagnostic Use

For In Vitro Diagnostic Use SYNCHRON System(s) Chemistry Information Sheet Lactate Dehydrogenase REF 442660 For In Vitro Diagnostic Use ANNUAL REVIEW Reviewed by: Date Reviewed by: Date PRINCIPLE INTENDED USE reagent, when used in

More information

MEDICAL LASER SYSTEMS

MEDICAL LASER SYSTEMS MEDICAL LASER SYSTEMS MELSYTECH Ltd. MELSYTECH Ltd. (Nizhny Novgorod Region, Russia) is an international developer, manufacturer and supplier of medical laser systems. MELSYTECH Ltd. offers all well-known

More information

AN INNOVATIVE METHOD TO PREPARE FORMALIN FREE MODELS BY PARAFFIN IMPREGNATION OF HUMAN ORGANS- HEART, BRAIN, SPLEEN AND LIVER

AN INNOVATIVE METHOD TO PREPARE FORMALIN FREE MODELS BY PARAFFIN IMPREGNATION OF HUMAN ORGANS- HEART, BRAIN, SPLEEN AND LIVER Original Research Article AN INNOVATIVE METHOD TO PREPARE FORMALIN FREE MODELS BY PARAFFIN IMPREGNATION OF HUMAN ORGANS- HEART, BRAIN, SPLEEN AND LIVER L.K. Jain 1, Hitesh Babel * 2. ABSTRACT Background:

More information

Challenges for Flow Cytometry in Regulated Bioanalysis

Challenges for Flow Cytometry in Regulated Bioanalysis Challenges for Flow Cytometry in Regulated Bioanalysis Minesh Patel Merck Millipore Discovery & Development Solutions. Oxford, UK. Overview Flow cytometry principles Current uses and regulatory environments

More information

Electron microscopy technology of reticulocytes after sorting with

Electron microscopy technology of reticulocytes after sorting with Electron microscopy technology of reticulocytes after sorting with magnetic beads The Cell Analysis Center Scientific Bulletin Part 2 For efficient analysis of cells, sorting of the target cells is crucial.

More information

Ultrasound Segmentation in Navigated Liver Surgery

Ultrasound Segmentation in Navigated Liver Surgery Ultrasound Segmentation in Navigated Liver Surgery Sylvain Anderegg, Matthias Peterhans, Stefan Weber University of Bern, Institute for Surgical Technology & Biomechanics (ISTB), Bern, Switzerland Contact:

More information

DORNIER MEDILAS H SOLVO 35 THE PULSE OF PERFORMANCE TARGETED LASER STONE MANAGEMENT

DORNIER MEDILAS H SOLVO 35 THE PULSE OF PERFORMANCE TARGETED LASER STONE MANAGEMENT DORNIER MEDILAS H SOLVO 35 THE PULSE OF PERFORMANCE TARGETED LASER STONE MANAGEMENT LEADING TECHNOLOGY INNOVATIONS THAT IMPROVE LIFE Dornier MedTech is known for its revolutionizing technical advancements

More information

Dornier Medilas H Solvo and UroPulse Leading Holmium Lasers in Endourology

Dornier Medilas H Solvo and UroPulse Leading Holmium Lasers in Endourology Dornier Medilas H Solvo and UroPulse Leading Holmium Lasers in Endourology LASER LITHOTRIPSY W E ' R E A L L A B O U T P E O P L E. ERGONOMIC USER-FRIENDLY EFFICIENT POWERFUL SAFE EXPERTISE 2 Leading holmium

More information

DORNIER MEDILAS H SOLVO 35 THE PULSE OF PERFORMANCE TARGETED LASER STONE MANAGEMENT

DORNIER MEDILAS H SOLVO 35 THE PULSE OF PERFORMANCE TARGETED LASER STONE MANAGEMENT DORNIER MEDILAS H SOLVO 35 THE PULSE OF PERFORMANCE TARGETED LASER STONE MANAGEMENT LEADING TECHNOLOGY INNOVATIONS THAT IMPROVE LIFE Dornier MedTech is known for its revolutionizing technical advancements

More information

UvA-DARE (Digital Academic Repository) Factor XI as target for antithrombotic therapy van Montfoort, M.L. Link to publication

UvA-DARE (Digital Academic Repository) Factor XI as target for antithrombotic therapy van Montfoort, M.L. Link to publication UvA-DARE (Digital Academic Repository) Factor XI as target for antithrombotic therapy van Montfoort, M.L. Link to publication Citation for published version (APA): van Montfoort, M. L. (2014). Factor XI

More information

Erosion corrosion of mild steel in hot caustic. Part II: The evect of acid cleaning

Erosion corrosion of mild steel in hot caustic. Part II: The evect of acid cleaning Corrosion Science 48 (2006) 2660 2675 www.elsevier.com/locate/corsci Erosion corrosion of mild steel in hot caustic. Part II: The evect of acid cleaning Rihan Omar Rihan, Srdjan NeniT The Department of

More information

CT to Ultrasound Registration: A Porcine Phantom Study. J. Xiang, S. Gill, C. Nguan, P. Abolmaesumi and R. N. Rohling University of British Columbia

CT to Ultrasound Registration: A Porcine Phantom Study. J. Xiang, S. Gill, C. Nguan, P. Abolmaesumi and R. N. Rohling University of British Columbia CT to Ultrasound Registration: A Porcine Phantom Study J. Xiang, S. Gill, C. Nguan, P. Abolmaesumi and R. N. Rohling University of British Columbia 1 Motivation Ultrasound to CT registration can improve

More information

What Can We Learn from Animal Models of Coagulopathy and Bleeding (about plasma transfusion)?

What Can We Learn from Animal Models of Coagulopathy and Bleeding (about plasma transfusion)? Test What Can We Learn from Animal Models of Coagulopathy and Bleeding (about plasma transfusion)? William Sheffield Associate Director, Research CBS Centre for Innovation, and Professor, Pathology and

More information

ASSESSMENT OF INFLAMMATORY CYTOKINE REMOVAL BY A NOVEL ACTIVATED CARBON DEVICE IN A FLOWING SYSTEM INTRODUCTION

ASSESSMENT OF INFLAMMATORY CYTOKINE REMOVAL BY A NOVEL ACTIVATED CARBON DEVICE IN A FLOWING SYSTEM INTRODUCTION ASSESSMENT OF INFLAMMATORY CYTOKINE REMOVAL BY A NOVEL ACTIVATED CARBON DEVICE IN A FLOWING SYSTEM Sandeman, S.R. 1, Howell. C.A. 1, Phillips, G.J. 1, Lloyd, A.W. 1*, Davies, J.G. 1, Mikhalovsky, S.V.

More information

6/15/15. Dear Editorial Board,

6/15/15. Dear Editorial Board, 6/15/15 Dear Editorial Board, Thank you to the editor and reviewers for their thoughtful comments. We have revised the previously submitted manuscript by addressing all of the comments provided by the

More information

Setting The practice setting was secondary care. The economic study was carried out in Athens, Greece

Setting The practice setting was secondary care. The economic study was carried out in Athens, Greece Comparison of success rates and financial cost of extracorporeal shock-wave lithotripsy in situ and after manipulation for proximal ureteral stones Varkarakis J, Protogerou V, Albanis S, Sofras F, Deliveliotis

More information

ENSEAL G2 Articulating Tissue Sealer Product Literature

ENSEAL G2 Articulating Tissue Sealer Product Literature ENSEAL G2 Articulating Tissue Sealer Product Literature For complete product details, see Instructions for Use. Executive Overview The first, and only, articulating advanced energy device compatible with

More information

Surgical/Cytology Specimen Collection and Handling

Surgical/Cytology Specimen Collection and Handling Surgical/Cytology Specimen Collection and Handling To ensure that hospital departments and outside sources submitting specimens to the surgical pathology department follow the established methods to guard

More information

Super absorbent wound dressing P1

Super absorbent wound dressing P1 Super absorbent wound dressing P1 Wounds, in particular chronic wounds, can lead to a considerable reduction in quality of life. Pain, loss of mobility as well as wound exudation and the smell of the wound

More information

Looking for clinical trial in dermatology field

Looking for clinical trial in dermatology field Technology Request Summary Looking for clinical trial in dermatology field A French company specialized in cosmetics have patented a new formulation for one of its product. The owner of the company would

More information

-- Laki J. Rousou, MS, MD et. al. -- Boston, Massachusetts. -- Ann Thorac Surg 2009;87:62 70.

-- Laki J. Rousou, MS, MD et. al. -- Boston, Massachusetts. -- Ann Thorac Surg 2009;87:62 70. -- Laki J. Rousou, MS, MD et. al -- Boston, Massachusetts. -- Ann Thorac Surg 2009;87:62 70. Presented by: Int. 黃柏翔 Date: 2009 /02 / 25 Patient outcome after CABG surgery greatly influenced by patency

More information

Presenting SURGICEL Powder

Presenting SURGICEL Powder SURGICEL Powder Presenting SURGICEL Powder Built to stop continuous, broad-surface oozing fast1,2 The next generation of SURGICEL Absorbable Hemostats SURGICEL Powder efficiently and effectively controls

More information

Disclosure. Lowell Kabnick, M.D., FACS, FACPh. I disclose the following financial relationship(s):

Disclosure. Lowell Kabnick, M.D., FACS, FACPh. I disclose the following financial relationship(s): Disclosure Lowell Kabnick, M.D., FACS, FACPh I disclose the following financial relationship(s): Research Grant: BTG; Ownership Interest: AngioDynamics, Vascular Insights; Consultant/Advisory Board: AngioDynamics,

More information

Interventional Fluoroscopy

Interventional Fluoroscopy NATIONAL CANCER INSTITUTE THE SOCIETY OF INTERVENTIONAL RADIOLOGY Interventional Fluoroscopy Reducing Radiation Risks for Patients and Staff CONTENTS Introduction 1 Increasing use and complexity of interventional

More information

Build With VICTUS. Build Your Patient Offerings. Build Your Premium Practice. FEATURING VICTUS 3.3 SOFTWARE

Build With VICTUS. Build Your Patient Offerings. Build Your Premium Practice. FEATURING VICTUS 3.3 SOFTWARE Build Your Patient Offerings. Build Your Premium Practice. Build With VICTUS. The VICTUS femtosecond laser workstation delivers multi-mode versatility for cataract and corneal procedures on a single platform.

More information

Development of non-substantially manipulated cell-based ATMPs 1 : flexibility introduced via the application of the risk-based approach

Development of non-substantially manipulated cell-based ATMPs 1 : flexibility introduced via the application of the risk-based approach 3 July 2017 EMA/CAT/216556/2017 Inspections, Human Medicines, Pharmacovigilance and Committees Division Development of non-substantially manipulated cell-based ATMPs 1 : flexibility introduced via the

More information

Part 1 examination. Clinical Biochemistry: First paper. Tuesday 26 September Candidates must answer FOUR questions only

Part 1 examination. Clinical Biochemistry: First paper. Tuesday 26 September Candidates must answer FOUR questions only Tuesday 26 September 2017 Candidates must answer FOUR questions only Time allowed: three hours 1. Outline how pre-analytical factors can affect the results of clinical biochemistry tests and describe what

More information