Data File #F808-DST-004-Rev1. TruTorr Single-Use Sensor
|
|
- Heather Gallagher
- 6 years ago
- Views:
Transcription
1 Data File #F808-DST-004-Rev1 TruTorr Single-Use Sensor
2 TruTorr Single-Use Headspace Pressure Sensor TruTorr SmartSensors The TruTorr pressure sensor is a single-use solution for measuring headspace pressure and preventing rupture of a bioprocess container. A TruTorr loop consists of a disposable pressure sensor, a cable, and a transmitter blade that is seamlessly integrated into a Finesse bioreactor controller. The single-use sensor is sealed into an insertion port of a disposable bioreactor bag and sterilized in place, so that process sterility is guaranteed. TruTorr single-use sensors use only USP Class VI materials, compensate for temperature, are pre-calibrated and provide full traceability information using a gamma radiation resistant SmartChip. Features Single-use pressure sensor, cable and blade Self-calibrated for immediate use Wetted materials USP Class VI Plug-and-play Easy-to-use Gamma radiation resistant to 50 kgy Smart Calibration // SmartChip Finesse TruTorr sensors contain embedded SmartChips that hold factory calibration data and are gamma radiation resistant. The SmartChip also holds manufacturing lot and serial numbers that can be part of the batch record when used with the blade transmitter. TruTorr Blade Transmitters TruTorr transmitter blades are mounted within an enclosure in a Finesse bioreactor controller. The TruTorr transmitter provides automatic input of calibration data from the sensor s SmartChip and provides diagnostic information to the bioreactor control system. The Virtual Transmitter module in Finesse TruBio software allows full access to all of the blade s functions, simulates a physical transmitter, and provides alarms and connectivity monitoring capability. Calibration of the sensor is performed in TruBio software.
3 TruTorr Sensor ENVIRONMENTAL SPECIFICATIONS Operating Temperature Operating Pressure (Typical) Storage Temperature Storage Relative Humidity Altitude Materials 15 C to 45 C (59ºF to 113ºF) 1 bar / 14.7 psi 0 C to 60 C (32ºF to 140 F) 10% to 90% (non-condensing) m (40000 feet) USP Class VI PERFORMANCE SPECIFICATIONS Sample Rate Settings Measuring Range Relative Accuracy Accuracy Response Time (T90 Agitated) Drift (21 days) Calibration Gamma Radiation Cross Sensitivity Temperature Accuracy Temperature Precision 1 Second 0 to 0.48 barg / 0 to 7 psig 0.7 mbarg / 0.01 C: ±0.014 barg / ±0.2 psig or ±2% of the reading, whichever is greater (inc. drift 21 days) <1 Second 13.6 mbarg / 0.2 psig Pre-calibrated (SmartChip) 1-pt standardization optional Standard range: 26 to 38 kgy, for radiation doses outside of this range contact Finesse directly None Automatic compensation over operating range ±0.1 C
4 TruTorr Blade Transmitter SPECIFICATIONS Power Supply Signal Outputs (Isolated / 4 to 20 ma) Output Accuracy Transmitter Diagnostics Calibration RFI / EMI Operating Temperature Storage Temperature Relative Humidity ma Isolated / 4 to 20 ma / 1x Pressure ±0.1 ma Internal diagnostics for sensor and loop Based on NIST-traceable standards, entered automatically using SmartChip, Optional 1-point standardization EN C to 45 C (41 F to 113 F) 0 C to 65 C (32 F to 149 F) 10% to 90% (non-condensing) PHYSICAL DESCRIPTION Case Material Rating Dimensions (H x W x D) Mounting / Conduits Display Weight / Shipping Weight Aluminum Bracket NEMA 1 (when mounted, same rating as enclosure) 130 x 35 x 128 mm (5.1 x 1.4 x 5 in) Mounted within utility tower (enclosure) Virtual transmitter in TruBio software (GAMP5) 0.1 kg / 0.3 kg (0.2 lb / 0.6 lb) Warranty: Each TruFluor Transmitter is warranted for one full year (12 months) from date of shipment against defects in material and workmanship. Blade transmitters are only sellable to approved OEM customers or as spare parts for Finesse control systems.
5 Finesse Solutions, Inc. Global Headquarters 3501 Leonard Court Santa Clara, CA USA Toll free Tel Fax Europe Via Sogn Gieri 27a CH-7402 Bonaduz, Switzerland Benelux, Ireland & Scandinavia Van Slingelandtlaan JJ Zwijndrecht The Netherlands Asia-Pacific 3A Intl Business Park, #07-08 ICON@IBP Tower A Singapore Shanghai Every effort has been made to ensure the accuracy of the information in this document. However, Finesse reserves the right to change its products without notice. The following are Finesse Solutions, Inc. registered trademarks: TruView, TruBio, TruBio DV, TruBio µc, SmartOPC, TruService, TruTorr, TruFluor, TruLogic, TruConnect, TruMigrations, TruCables, TruHousings, SmartGlass, SmartRocker, TruDO, TrupH, SmartFactory, SmartChip, SmartSystems, SmartBag, SmartPuck, SmartReader, SmartBag Reader, SmartTray, SmartController, SmartSensor , Finesse Solutions, Inc. All other trademarks are the property of their respective owners.
Xpansion Multiplate Bioreactor System
USD939 (1) Xpansion Multiplate Bioreactor System Multiplate bioreactor for cell-based product manufacturing Features and Benefits USP Class VI certified materials Designed for adherent cell culture applications
More informationRosemount 1152 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment
More informationRosemount 1154 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10
More informationA World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...
A World of Gases A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter... ATI Presents A Simpler Approach To Toxic Gas Detection. One Transmitter Is All You Need. Time was, monitoring multiple
More informationRHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits
RHM80 High Flow Coriolis Mass Flow Meter Features Standard pressure ratings up to 341 bar (4946 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty
More informationInstruction Manual HI RH/ C Transmitter. This Instrument is in Compliance with the CE Directives.
Instruction Manual HI 8666 RH/ C Transmitter This Instrument is in Compliance with the CE Directives www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this
More informationRack Power Distribution Unit AP7562, AP7563, AP7564 General Information
Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information Description This booklet provides information on installing and operating the Rack Power Distribution Units (PDUs) AP7562, AP7563,
More informationUsing the PPM2 Portable Trace Moisture Transmitter
APPLICATION NOTE 2016_0106 PPM2 Using the PPM2 Portable Transmitter The Model PPM2 Portable analyzer is a compact, cost effective, analyzer specifically designed to continuously measure low levels of moisture
More informationINSTALLATION PROCEDURE
INSTALLATION PROCEDURE ELECTRA-flo/FI INSPECTION & HANDLING. The ELECTRA-flo/FI should be carefully inspected for damage prior to installation. Report damage to your Freight Department, or contact delivery
More informationWing Union/Hammer Union Pressure Sensors Models 434, 435, Issue 3. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION
Wing Union/Hammer Union Pressure Sensors Models 434, 435, 437 32301963 Issue 3 Datasheet Model 434 with cage not pictured. DESCRIPTION Models 434/435/437 Wing Union/Hammer Union Pressure Sensors are designed
More informationRosemount Annubar Flowmeter Series. The Value of Innovation, Realized
Rosemount Annubar Flowmeter Series The Value of Innovation, Realized Insertion Technology, Simplified. Averaging Pitot Tube (APT) technology reduces the total cost of ownership of the flow measurement
More informationShur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual
Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual P/N 1000006053 Rev E $7%$QDO\WLFV// //& 733 Dairy Rd. Parkton, Md. 21120 www.atbanalytics.com (410) 733-6365 Table of Contents Chapter 1: Getting
More informationETHYLENE PLANT DRY CRACKED GAS Product Code 54801
SS2100 WATER IN ETHYLENE PLANT DRY CRACKED GAS Product Code 54801 KEY FEATURES Extremely fast analysis time 1 second updates possible Non-contact laser and detector - Reliable Tunable Diode Laser lasts
More informationSensor unit MC2 for toxic gases and oxygen with analog output
Page 1 July 2016-2 Exchangeable sensor unit including digital value processing, temperature compensation and self control for the continuous monitoring of the ambient air. The sensor unit MC2 houses a
More informationLong-Range Reader/Writer
Features Read and Write to Dozens of Tags Simultaneously (Multiple-Tag-In-Field) Industrial Strength Reader/Writer (IP66) Large Read/Write Area International Recognized Frequency of 13.56 MHz RS422 Bus
More informationFractional Pressure Gauge Heavy Duty Pressure Gauge Homogenizer Pressure Gauge High Accuracy Pressure Transmitter Homogenizer Pressure Transmitter
Fractional Pressure Gauge Heavy Duty Pressure Gauge Homogenizer Pressure Gauge High Accuracy Pressure Transmitter Homogenizer Pressure Transmitter The Instrumentation Company INTRODUCTION Established
More informationKEy FEATuRES. Virtually maintenance free. No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime
KEy FEATuRES Virtually maintenance free No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime measurements No wet-up or dry-down delays Short term payback;
More informationXDR Single-Use Bioreactors
DATA SHEET XDR Single-Use Bioreactors Introduction The XDR Single-Use Bioreactor is a fully-integrated system that delivers proven stirred-tank performance across a wide range of cell lines. Single use
More informationSby SR Instruments, Inc.
Part No.: MAN947IFS_170629 Page 1 of 12 Sby SR Instruments, Inc. SRV947IFS REMOTE DISPLAY PLATFORM SCALE Operating and Service Manual Part No.: MAN947IFS_170629 Page 2 of 12 TABLE OF CONTENTS TABLE OF
More informationTSI Model 3063 Thermal Mass Flowmeter
Mass Flowmeters TSI Model 3063 Thermal Mass Flowmeter Operation and Service Manual 1930101, Revision D August 2010 Part Number 1930101 Copyright TSI Incorporated / Revision D / 2004-2010 / All rights
More informationNRF CAPACITANCE LEVEL TRANSMITTER
NRF CAPACITANCE LEVEL TRANSMITTER Flow Pressure Level Temperature measurement monitoring control N2 Rigid and Suspended Designs Compact Microprocessor Based Designs High Accuracy NPT Threaded and Tri-Clamp
More informationWelcome! CellWorld 2017 San Francisco, CA USA
Welcome! CellWorld 2017 San Francisco, CA USA Intensity Innovation Involvement Integrity Company (Business Unit) Overview Name: Finesse HQ: Santa Clara, CA Founded: 2005 Employees: ~150 Business Description
More informationInstallation. Basic Rack Power Distribution Units AP9560 AP9561
Installation Basic Rack Power Distribution Units AP9560 AP9561 Contents Preliminary Information...................1 AP9560...........................1 AP9561...........................1 Safety and Grounding....................2
More informationSECTION Coriolis Mass Flow Meters
SECTION 40 71 73 Coriolis Mass Flow Meters PART 1- GENERAL 1.01 SUMMARY A. Coriolis flow meter for permanent installation above ground. The meter shall utilize a measuring principle based on the controlled
More informationAM1730 Secondary Reference Platinum Resistance Thermometer User s Guide
AM1730 Secondary Reference Platinum Resistance Thermometer User s Guide Please download the latest version at www.accumac.com Rev. 201609V3 Table of Contents Before you start ---- Warnings & Cautions...
More informationNew! Sievers M9 TOC Analyzers
Now with Sample Conductivity! New! Sievers M9 TOC Analyzers Reach the peak of productivity Tools that boost productivity are essential to managing your chaotic workday. The new Sievers* M9 Total Organic
More informationTARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring
TARGAS-1 Portable Photosynthesis System Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring TARGAS-1 Main Console CO 2 & H 2 O Gas Analysis The TARGAS-1 console is compact, lightweight
More informationSentry QCIII Quick Connect System
ADVANCED MATERIALS HANDLING Sentry QCIII Quick Connect System The cleanest, safest, most user-friendly connection system available for highpurity bulk chemical dispense For more than 5 years, Entegris
More informationTriton TR8 Turbidity Analyzer
Triton TR8 Turbidity Analyzer The Clear Choice Water to Sludge ELECTRO-CHEMICAL DEVICES What is Turbidity? Standard Methods for the Examination of Water and Wastewater describes Turbidity as an expression
More informationSolutions for the future of biomanufacturing
Solutions for the future of biomanufacturing Dear Reader, Biomanufacturers today face new challenges to produce more efficiently, with increased quality. Many facilities have a mix of old and new equipment,
More informationCYTOPERM 2 CO 2 - AND CO 2
CYTOPERM 2 - AND / INCUBATOR Contamination protection that s in a class of its own Analyze Detect Measure Control TM CYTOPERM 2 GASSED INCUBATOR CELL CULTIVATION FOR THE 21ST CENTURY The Heraeus gassed
More informationModel 1159 Remote Diaphragm Seals
00813-0100-0 English May 1999 Rev. AB 119 Remote Diaphragm Seals with 112, 113 Series B, D and F, and 11 Alphaline Nuclear Pressure Transmitters Product Discontinued 119 Remote Diaphragm Seals Qualified
More informationSpectraSensors SS500 Mid-Sensitivity Moisture Analyzer
SpectraSensors SS500 Mid-Sensitivity Moisture Analyzer Key Features Virtually Maintenance Free No Interference from glycol, methanol or amine contaminants (vapor phase) Fast and Accurate Real-time Measurements
More informationC60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
For more information, visit www.247technology.com/on-line-ups/c60-standby-ups C60 Standby UPS 800VA Models User & Installation Manual 2015. All rights reserved. (Rev 6/23/15) Table of Contents Package
More informationProduct Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter
Liquid Ultrasonic Flow Meters Daniel 3812 Liquid Ultrasonic Flow Meter TM Daniel 3812 Liquid Ultrasonic Flow Meter A Reliable and Economical Solution for Liquid Products Measurement Daniel 3812 Liquid
More informationSentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications
GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available
More informationAM1760/1762 Secondary Standard Platinum Resistance Thermometer User s Guide
AM1760/1762 Secondary Standard Platinum Resistance Thermometer User s Guide 1/11 Table of Contents Before you start ---- Warnings & Cautions... 3 1 Introduction... 4 1.1 Main Application... 4 1.2 Main
More informationTwo Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers
Two Great Technologies Together At Last The 700 Series NanoTrace Moisture And Oxygen Analyzers w w w. d e l t a - f. c o m THE DF-750 NANOTRACE MOISTURE ANALYZER: THE DF-760 NANOTRACE DUAL ANALYZER: Redefining
More informationCompressed Air Filters 1/4 and 1/2 Line Size Filters
Compressed Air Filters Compressed Air Filters 1/4 and 1/2 Line Size Filters Models A914D, A914P, A914, A914A Models A914P and A914D are 1/4 line size assemblies with simple, reliable automatic drains used
More informationHDI 2200 Choke Position Indicator
HDI 2200 Choke Position Indicator Operations and Maintenance Manual Rev. 1203 www.houstondigital.com email: sales@houstondigital.com or service@houstondigital.com TABLE OF CONTENTS SECTION 1 SECTION 2
More informationMAX300-BIO PRODUCT NOTE. Bioreactor/Fermentation Control Process Efficiency Product Quality Analysis. Bioreactor/Fermentation Mass Spectrometer
MAX300-BIO Bioreactor/Fermentation Mass Spectrometer www.extrel.com PRODUCT NOTE Bioreactor/Fermentation Control Process Efficiency Product Quality Analysis Introducing the MAX300-BIO Know Your Process
More informationBrooks Mass Flow Meter Model 5863 Mass Flow Controller Model 5853
Installation and Operation Manual X-TMF-5853-63-MFC-eng PN 541-C-022-AAG November, 2008 Brooks Mass Flow Meter Model 5863 Mass Flow Controller Model 5853 Section 5 Information Installation
More informationSilica Analyzer. Automated Silica Measurement Dependable and Sensitive
Silica Analyzer 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity Grab sample capability Low maintenance Automated Silica Measurement Dependable and Sensitive Silica Analyzer 2800S i
More informationPD662 Loop-Powered Meter Instruction Manual
PD662 Loop-Powered Meter C US 4-20 ma Input Loop-Powered -1999 to 2999 Display Easy Four-Button Programming NEMA 4X Enclosure Loop-Powered Backlight Option 1.7 Volt Drop without Backlight 32-Point and
More informationFiberglass Cooling Towers
Fiberglass Cooling Towers Available in sizes from 100 to 240 tons. FC Series 700 Fiberglass Cooling Tower Available in sizes from 170 to 240 tons. No other fiberglass cooling tower comes with as many high-quality
More informationIsco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation
Isco EZ TOC Continuous on-line TOC/TC measurement using low-temperature oxidation Easy Programming High Efficiency UV Reactor Enhanced NDIR Detector Flexible Four-Motor Pump System Advanced Dual Calibration
More informationMicro Motion Technical Overview and Specification Summary
Product Data Sheet PS-00232, Rev. K April 2011 Micro Motion Technical Overview and Specification Summary Emerson s world-leading Micro Motion Coriolis flow and density measurement devices have set the
More informationIntegrated Single-Use Bioreactor (S.U.B.) systems with controllers
Integrated Single-Use Bioreactor (S.U.B.) systems with controllers Providing simplicity in operation Integrated Single-Use Bioreactor and controller systems Our integrated single-use bioreactors are designed
More informationTechnical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:
Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations Note: These are general specifications and guidelines for Mass Flow Meters for Petroleum Oil Installations.
More informationVortex EX DELTA lowmeter Technical Specifications
Product Data Sheet PDS-VX Vortex EX DELTA lowmeter Technical Specifications DESCRIPTION Rugged, yet simple, the Ex-DELTA vortex flowmeter is suitable for a variety of applications in liquid, gas, air and
More informationMeasurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum
Measurement & Analytics Measurement made easy AlSCAN TM and AlSCAN TM Argon Today s global economy and competition have compelled aluminum producers and aluminum foundries to produce the highest possible
More informationTemperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!
JC Series High Performance Controllers...at the lowest prices anywhere! Structure Units available in standard DIN sizes (1/16, 1/8, and 1/4 DIN) NEMA 4X protective construction Black enclosure Programmable
More informationAP-25 Plasma System AP-25 PLASMA THERMAL SPRAY SYSTEM
AP-25 PLASMA THERMAL SPRAY SYSTEM AP-25 Plasma System We set ourselves the challenge of producing a simple yet flexible, high tech system our customers can rely on. The result is the new 25-Series equipment
More informationGlobal Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com AT210 Soil Moisture
More informationRosemount Differential Pressure Level Solutions. Keeping You a Step Ahead
Rosemount Differential Pressure Level Solutions Keeping You a Step Ahead Finding it harder to keep a step ahead? Your time is important. So are the decisions you make. Staying a step ahead on projects,
More informationTable of Contents. Introduction 1. Description 1. Calibration 4. Installation 7. Operation 12. Maintenance & Troubleshooting 12
Table of Contents Introduction 1 Description 1 Calibration 4 Installation 7 Operation 12 Maintenance & Troubleshooting 12 Appendix A Intrinsic Safety Requirements A1 TRADEMARK: TEFLON is a registered trademark
More informationEuropean MID Directive for Custody Transfer Measuring Instruments Proven, certified technology for Fiscal & Custody transfer applications
European MID Directive for Custody Transfer Measuring Instruments Proven, certified technology for Fiscal & Custody transfer applications European Metrology Directive Legal metrology in Europe has undergone
More informationMATRIX TANK LEVEL MONITORING SYSTEM
MATRIX TANK LEVEL MONITORING SYSTEM Wireless transmission and reception of tank level information LUBRICATION PROVEN QUALITY. LEADING TECHNOLOGY. Matrix Wireless Tank Level Monitoring Technology EASY TO
More informationChloride/Sulfate Analyzer
Chloride/Sulfate Analyzer 3000CS Analyzer Trace sensitivity Low maintenance Grab sample capability Fully automatic calibration Automated Chloride/Sulfate Measurement Sensitive and Reliable Chloride/Sulfate
More informationOxiPRO Q2.0 Microbial Control Technology
OxiPRO Q2.0 Microbial Control Technology Specification SPEC-613 OxiPRO Q2.0 Microbial Control Technology improves paper machine efficiency by proactively monitoring and controlling microbial-based deposits.
More informationReference thermometer Model CTP5000
Calibration technology Reference thermometer Model CTP5000 WIKA data sheet CT 61.20 Applications Reference thermometer for measuring very accurate temperature in a range of -196... +660 C [-321... +1,220
More informationDigital E3 Modulevel Liquid Level Displacer Transmitter
Digital E3 Modulevel Liquid Level Displacer Transmitter D E S C R I P T I O N The Digital E3 Modulevel is an advanced, intrinsically safe two-wire instrument utilizing simple buoyancy principle to detect
More informationInstrument technology moves into process development laboratories
Instrument technology moves into process development laboratories The same instruments can be used in process development laboratories, clinical trials, pilot plants and large scale manufacturing thus
More informationSwitch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches
Switch-Tek Sump Float Level Switches LV41 & LV42 Series Manual LV41 Series Shown LV42 Series Shown Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f 562.431.8507 w flowline.com
More informationPS162 Ceramic Capacitive High Pressure Sensing Modules
Data Sheet PS162 Ceramic Capacitive High Pressure Sensing Modules Main Features Electrical Connection Housing Material Output Signal 0 to 0.04 bar up to 0 to 60 bar (gage) 0 to 1 up to 0 to 60 bar (absolute)
More informationi-control Complete Process Control
icontrol icontrol TOTAL TOTAL CONTROL CONTROL MAKE MAKE SELECTION SELECTION SELECT CONTROL OPTION FOR I-CONTROL i-control Complete Process Control Applikon Biotechnology T H E B I O P R O C E S S I N G
More informationWS 10 Weighing indicator USER MANUAL
WS 10 Weighing indicator USER MANUAL Edition:10052001A Safety Instruction For safety operation follow the safety instructions. WARNING Setting, Calibration Inspection and Maintain of the indicator is prohibited
More informationThis Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /
This Specification Data Sheet brought to you by: 15825 Trinity Blvd. Fort Worth, Texas 76155 817/465-9494 equipment@technicaldiagnostic.com www.technicaldiagnostic.com www.test-equipment-rental.com The
More informationAM1620 Precision Industrial Platinum Resistance Thermometer User s Guide
AM1620 Precision Industrial Platinum Resistance Thermometer Table of Contents Before you start ---- Warnings & Cautions... 2 1 Introduction... 3 1.1 Main Application... 3 1.2 Main Features... 3 1.3 Calibrations...
More informationXMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor
Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output
More informationAcoustic and Vibration Isolation for Asylum Research AFMs
Vibration Enclosures and Tables Acoustic and Vibration Isolation for Asylum Research AFMs DATA SHEET 01 Isolation from the lab environment plays an important role in image and measurement quality. Our
More informationBILFINGER INDUSTRIETECHNIK SALZBURG GMBH BIOREACTORS AND FERMENTERS
BILFINGER INDUSTRIETECHNIK SALZBURG GMBH BIOREACTORS AND FERMENTERS 2 Bioreactors and fermenters BILFINGER INDUSTRIETECHNIK SALZBURG At Bilfinger Industrietechnik Salzburg, we have decades of experience
More informationTroubleshooting Guide 9702 Series
Troubleshooting Guide 9702 Series Satellite Solutions for Mobile Markets 11200 Hampshire Avenue South, Bloomington, MN 55438-2453 Phone: (800) 982-9920 Fax: (952) 922-8424 www.kingcontrols.com 1305-AUTO
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationRed Eye Multiphase Water-Cut Meter
Red Eye Multiphase Water-Cut Meter Water-cut measurements in multiphase flow. Weatherford has redefined the water-cut meter market by addressing many of the difficulties in accurately measuring water cut
More information7700 TEST KIT OPERATIONS MANUAL
7700 TEST KIT OPERATIONS MANUAL 1 The following specifications apply to the CosaTron Model 7700 Digital Test Kit. SPECIFICATIONS: HV DISPLAY ------------------------------------------- 3 Digit (XX.X KV),
More informationDRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale
Instruction Manual DRS220 Digital Refrigerant Scale DRS220 Digital Refrigerant Scale Limited Warranty The DRS220 Digital Refrigerant Scale is warranted to be free from defects in materials and workmanship
More informationMD Power Supply -48Vdc +Bias Tee
215988-001MD Power Supply -48Vdc +Bias Tee Operation and Maintenance Manual Mitec Telecom Inc. Designers and manufacturers of telecom and wireless products 9000 Trans Canada, Pointe-Claire, Quebec, Canada
More informationOvation GE LM6000 Control System Retrofit
Ovation GE LM6000 Control System Retrofit Features Fully engineered and field-proven retrofit for LM6000 turbines equipped with legacy Netcon, Micronet, Mark V, Mark VI Millennium and other control systems
More informationTELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700
TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700 UV / Heated Persulfate Method Ozone / Hydroxyl Radical Method Combustion Method Ultrapure Method The Series 6700 covers a complete range of Total Organic Carbon
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationManual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5
Manual Rotary Heat Sealers Type: F108TX List of content : Page: Introduction 2 General description 3 Application 4 Safety precautions 5 Transport and storage 6 Installation 7 First Set-up 8 Connection
More informationIndustrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series
Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series 70-82-03-14 June 08 Page 1 of 8 Specification Main Overview The specification of an Electrolytic Conductivity Cell requires
More informationTechnology update: SmartFactory solutions for continuous processing. Barbara A. Paldus June 12, 2017
Technology update: SmartFactory solutions for continuous processing Barbara A. Paldus June 12, 2017 What is Perfusion? Definition: Continuously adding nutrient solutions to a bioreactor while removing
More informationComp. Tag No. Component Title Options Installation Detail No.
INSTRUMENTATION LIST Project Waste Water Treatment Facility No. 2 Revision Date: Nov 2014 Client City of Winter Haven Utilities, Florida Revised By: D. Fitzgerald Comp. Tag No. Component Title Options
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationProcess Total Organic Carbon Analyzer
Process Total Organic Carbon Analyzer FEATURES The Model 2100A Process Total Organic Carbon Analyzer is an on-line analyzer for industrial water applications in the ranges from 0 to 2 parts-per-million
More information3SP_CO_1000 Package
15x15 CO Sensor 1000 ppm Package 110-102 BENEFITS Small Size with Low Profile (20x20x3.8 mm) Long Life (10 years expected life) Fast Response (< 15 seconds) Robust (passes 5000 ppm overload) Low Power
More informationWeighing Terminals. IND780 Connectivity Communications Customized Solutions. Power and Performance for Advanced Weighing Applications
Weighing Terminals IND780 Connectivity Communications Customized Solutions Power and Performance for Advanced Weighing Applications IND780 Weighing Terminal Powerful performance increases productivity
More informationL505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL
L505 VISUAL LEVEL INDICATOR INSTALLATION AND OPERATIONS MANUAL Dip-Tape Visual Level Indicator READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the L505 Dip-Tape Visual Level
More informationXDS TM Multipurpose NIR-analyser for Laboratories
XDS TM Multipurpose NIR-analyser for Laboratories The multipurpose NIR-analyser for laboratories with ISIscan software, provides rapid non-destructive analysis of virtually any solid, viscous and liquid
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationTHE KENYA POWER AND LIGHTING CO. LTD
THE KENYA POWER AND LIGHTING CO. LTD SPECIFICATION for SINGLE PHASE STATIC METERS FOR ACTIVE ENERGY Compiled by NAME DESIGNATION SIGNATURE DATE Ephantus Nyagah Ag. Senior Engineer Checked by Approved by
More informationUser s Guide IP610 SERIES. I/P Converters. Shop online at. omega.com For latest product manuals: omegamanual.
User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info IP610 SERIES I/P Converters OMEGAnet Online Service www.omega.com Internet e-mail info@omega.com
More informationOmron Robotic Automation Complete automation expertise
Omron Robotic Automation Complete automation expertise 2 Omron Robotic Automation Omron Robot Solution Flexible manufacturing enabled by a seamless integration of Robots and Machine Control Omron s unique
More informationGlobal Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 151 Graham Road P. O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, F: (979) 690-0440 E-mail : globalw@globalw.com WS700 Sampler 01-455
More informationMAGFLO. Flow metering based on electromagnetic technology. For value-adding performance you can count on. FLOW DIVISION Simply Better
MAGFLO Flow metering based on electromagnetic technology For value-adding performance you can count on FLOW DIVISION Simply Better VALUE-ADDING PERFORMANCE Discover the value-adding advantages of MAGFLO
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationFGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications
Applications An ex situ zirconium oxide analyzer for excess oxygen measurement in dirty, rugged combustion applications such as: Boilers: all fuels and all types, including marine, recover, and utility
More informationMANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands
MANUAL ENGLISH Antenna Booster V1 Highlite International B.V. Vestastraat 2 6468 EX Kerkrade the Netherlands Table of contents Warning... 2 Unpacking Instructions... 2 Safety Instructions... 2 Operating
More information