Flow cytometry products for 30 tests!
|
|
- Clement Eaton
- 6 years ago
- Views:
Transcription
1 Small size great performance Flow cytometry products for 30 tests To further enable high performance, multicolor flow cytometry, Miltenyi Biotec is introducing new vial sizes for 30 tests in its most popular specificities. These products are a cost effective method to validate pilot experiments and optimize multicolor panels. Smaller vial sizes suitable for all budgets Perfectly suited to small scale experiments Quality and consistency based on Miltenyi Biotec s high quality standards Product list Human CD1c (BDCA-1) APC CD1c (BDCA-1) Biotin CD1c (BDCA-1) FITC CD1c (BDCA-1) PE CD2 FITC CD2 APC CD2 VioBlue CD3 APC CD3 APC-Vio CD3 FITC CD3 PE CD3 PE-Vio CD3 PerCP CD3 VioBlue CD3 VioGreen CD4 APC CD4 FITC CD4 PE CD4 (VIT4) APC CD4 (VIT4) APC-Vio CD4 (VIT4) FITC CD4 (VIT4) PE CD4 (VIT4) PE-Vio CD4 (VIT4) PerCP CD4 (VIT4) VioBlue CD4 (VIT4) VioGreen CD6 Biotin CD8 APC CD8 APC-Vio CD8 Biotin CD8 FITC CD8 PE CD8 PE-Vio CD8 PerCP CD8 VioBlue CD8 VioGreen CD14 APC CD14 APC-Vio CD14 FITC CD14 PE CD14 PE-Vio CD14 PerCP CD14 VioBlue CD14 VioGreen CD15 APC CD15 FITC CD15 PE CD15 VioGreen CD16 APC CD16 APC-Vio CD16 FITC Flow cytometry products for 30 tests October Copyright 2012 Miltenyi Biotec GmbH. All rights reserved.
2 CD16 PE CD16 VioGreen CD19 APC CD19 APC-Vio CD19 FITC CD19 PE CD19 PE-Vio CD19 VioBlue CD20 FITC CD20 PE CD20 PerCP CD20 VioBlue CD20 VioGreen CD25 APC CD25 Biotin CD25 PE CD27 APC CD27 APC-Vio CD27 Biotin CD27 FITC CD27 PE CD30 FITC CD30 APC CD30 Biotin CD30 VioBlue CD31 APC CD31 FITC CD31 PE CD33 FITC CD34 APC CD34 Biotin CD34 FITC CD34 PE CD34 VioBlue CD44 APC CD44 FITC CD44 PE CD45 APC CD45 APC-Vio CD45 Biotin CD45 FITC CD45 PE CD45 PE-Vio CD45 PerCP CD45 VioBlue CD45 VioGreen CD45RA APC CD45RA APC-Vio CD45RA Biotin CD45RA FITC CD45RA PE CD45RA PE-Vio CD45RA PerCP CD45RA VioBlue CD45RA VioGreen CD56 APC CD56 PE CD56 PE-Vio CD61 FITC CD61 VioBlue CD61 APC CD62L VioBlue CD73 APC CD73 PE CD73 Biotin CD79a PE CD79a APC CD86 APC CD86 FITC CD86 PE CD90 APC CD90 FITC CD90 PE CD105 FITC CD117 APC CD117 PE CD117 Biotin CD123 Biotin CD127 FITC CD127 PE CD133/2 (293C3) APC CD133/2 (293C3) PE CD138 APC CD138 PE CD138 VioGreen CD142 FITC Flow cytometry products for 30 tests October Copyright 2012 Miltenyi Biotec GmbH. All rights reserved.
3 CD142 PE CD142 APC CD142 VioBlue CD142 VioGreen CD142 Biotin CD146 APC CD146 Biotin CD146 FITC CD146 PE CD158f APC CD159 (NKG2A) FITC CD159 (NKG2A) PE CD159 (NKG2A) APC CD159 (NKG2A) Biotin CD165 PE CD165 APC CD165 Biotin CD169 (Siglec-1) FITC CD169 (Siglec-1) PE CD169 (Siglec-1) APC CD169 (Siglec-1) PE-Vio CD169 (Siglec-1) Biotin CD180 (RP105) PerCP-Vio CD197 (CCR7) APC CD197 (CCR7) PE CD271 (LNGFR) APC CD271 (LNGFR) Biotin CD271 (LNGFR) FITC CD271 (LNGFR) PE CD273 (B7-DC) FITC CD326 PE CD326 VioBlue CD329 (SIGLEC-8) FITC CD329 (SIGLEC-8) PE CD329 (SIGLEC-8) APC CD329 (SIGLEC-8) Biotin CD357 (GITR) APC Anti-TCR/" FITC Anti-TCR/" VioBlue CLA APC HLA-DR APC HLA-DR FITC HLA-DR PE HLA-DR PerCP HLA-DR VioBlue FOXP3 APC FOXP3 PE IFN-# APC IFN-# APC-Vio IFN-# FITC IFN-# PE IFN-# PE-Vio IgD PE-Vio inkt APC inkt PE inkt Biotin Anti-KIR2D FITC Anti-TIM-3 PE Anti-TIM-3 APC Anti-TIM-3 Biotin CD273 (B7-DC) PE CD273 (B7-DC) APC CD273 (B7-DC) Biotin CD275 (B7-H2) FITC CD275 (B7-H2) PE CD275 (B7-H2) APC CD275 (B7-H2) Biotin CD303 (BDCA-2) APC CD303 (BDCA-2) Biotin CD303 (BDCA-2) FITC CD303 (BDCA-2) PE CD326 APC CD326 FITC Mouse CD3$ APC CD3$ Biotin CD3$ FITC CD3$ PE CD3$ PE-Vio CD3$ VioBlue CD4 APC CD4 APC-Vio CD4 FITC Flow cytometry products for 30 tests October Copyright 2012 Miltenyi Biotec GmbH. All rights reserved.
4 CD4 PE CD4 PE-Vio CD4 VioBlue CD4 VioGreen CD4 PE-Vio CD8a APC CD8a APC-Vio CD8a FITC CD8a PE CD8a PE-Vio CD8a PerCP CD8a VioBlue CD8a VioGreen CD9 PerCP-Vio CD11c APC CD11c FITC CD11c PE CD11c VioBlue CD11c Biotin CD19 APC CD19 APC-Vio CD19 FITC CD19 PE CD19 PE-Vio CD25 APC CD25 Biotin CD25 PE CD45 APC CD45 FITC CD45 PE CD45 PerCP CD45 VioBlue CD45 VioGreen CD45R (B220) APC CD45R (B220) APC-Vio CD45R (B220) FITC CD45R (B220) PE CD45R (B220) PerCP CD45R (B220) PE-Vio CD45R (B220) VioBlue CD45R (B220) VioGreen CD45R (B220) Biotin CD49b (DX5) FITC CD49b (DX5) PE CD49b (DX5) APC CD61 FITC CD61 PE CD61 APC CD61 Biotin CD105 APC CD105 Biotin CD105 PE CD117 APC CD117 PE CD117 Biotin CD127 APC CD146 (LSEC) PE CD146 (LSEC) APC CD252 (OX40L) PE CD252 (OX40L) APC CD252 (OX40L) Biotin Anti-Gr-1 APC Anti-Gr-1 Biotin Anti-Gr-1 FITC Anti-Gr-1 PE Anti-Gr-1 PerCP Anti-Gr-1 VioBlue Anti-IgG1 APC Anti-IgG1 FITC Anti-IgG1 PE Anti-IgG2ab APC Anti-IgG2ab Biotin Anti-IgG2ab FITC Anti-IgG2ab PE Anti-IgG2ab VioGreen Anti-Ly49A FITC Anti-Ly49A PE Anti-Ly49A APC Anti-Ly49A PE-Vio Anti-Ly49A PerCP-Vio Anti-Ly49A Biotin Anti-Ly49D FITC Anti-Ly49D PE Anti-Ly49D APC Anti-Ly49D VioBlue Anti-Ly49D VioGreen Flow cytometry products for 30 tests October Copyright 2012 Miltenyi Biotec GmbH. All rights reserved.
5 Anti-Ly49D PE-Vio Anti-Ly49D PerCP-Vio Anti-Ly49D Biotin Anti-Ly49G PE Anti-Ly49G APC Human, Mouse and rat A2B5 APC A2B5 Biotin A2B5 PE Anti-Ly6B.2 FITC Anti-Ly6B.2 PE Anti-Ly6B.2 APC Anti-Ly6B.2 Biotin Anti-NKp46 APC Anti-NKp46 Biotin Anti-NKp46 FITC Anti-NKp46 PE Anti-NOTCH-2 PE Human, Mouse and Non-Human Primate CD11b APC CD11b APC-Vio CD11b FITC CD11b PE CD11b VioBlue CD11b VioGreen Anti-NOTCH-2 APC Anti-NOTCH-2 Biotin Anti-PDCA-1 APC Anti-PDCA-1 Biotin Anti-PDCA-1 FITC Anti-PDCA-1 PE Anti-Prominin-1 APC Anti-Prominin-1 Biotin Anti-Prominin-1 PE Anti-Sca-1 APC Anti-Sca-1 Biotin Anti-Sca-1 FITC Anti-Sca-1 PE Anti-T-Bet PE Anti-T-Bet APC Other reagents Annexin V Biotin Annexin V FITC Isotype control antibodies Mouse IgG1 PE-Vio Mouse IgG2b PE-Vio Mouse IgG2b PerCP Mouse IgG2b VioBlue Mouse IgM PerCP-Vio Mouse IgM PerCP Mouse IgM VioBlue Flow cytometry products for 30 tests October Copyright 2012 Miltenyi Biotec GmbH. All rights reserved.
6 Germany/Austria/ Switzerland Miltenyi Biotec GmbH Friedrich-Ebert-Straße Bergisch Gladbach Germany Phone Fax USA/Canada Miltenyi Biotec Inc Lindbergh Street Auburn, CA 95602, USA Phone 800 FOR MACS Phone Fax Australia Miltenyi Biotec Australia Pty. Ltd. Unit 16A, 2 Eden Park Drive North Ryde, NSW 2113, Australia Phone Fax macs@miltenyibiotec.com.au Benelux Miltenyi Biotec B.V. Schipholweg 68 H 2316 XE Leiden The Netherlands macs@miltenyibiotec.nl Customer service The Netherlands Phone Fax Customer service Belgium Phone Fax Customer service Luxembourg Phone Fax China Miltenyi Biotec GmbH Shanghai Office Rm No. 319 Xianxia Rd. Shanghai , P.R. China Phone Fax macs@miltenyibiotec.com.cn France Miltenyi Biotec SAS 10 rue Mercoeur Paris, France Phone Fax macs@miltenyibiotec.fr Italy Miltenyi Biotec S.r.l. Via Persicetana, 2/D Calderara di Reno (BO) Italy Phone Fax macs@miltenyibiotec.it Japan Miltenyi Biotec K.K. Nittsu-Eitai Building 5F Fuyuki, Koto-ku, Tokyo , Japan Phone Fax macs@miltenyibiotec.jp Nordics and Baltics Miltenyi Biotec Norden AB Scheelevägen Lund Sweden macs@miltenyibiotec.se Customer service Sweden Phone Fax Customer service Denmark Phone Fax Customer service Norway, Finland, Iceland, and Baltic countries Phone Fax Singapore Miltenyi Biotec Asia Pacific Pte Ltd. 100 Beach Road #28-06 to Shaw Tower Singapore Phone Fax macs@miltenyibiotec.com.sg Spain Miltenyi Biotec S.L. C/Luis Buñuel 2 Ciudad de la Imagen Pozuelo de Alarcón (Madrid) Spain Phone Fax macs@miltenyibiotec.es United Kingdom Miltenyi Biotec Ltd. Almac House, Church Lane Bisley, Surrey GU24 9DR, UK Phone Fax macs@miltenyibiotec.co.uk Miltenyi Biotec provides products and services worldwide. Visit to find your nearest Miltenyi Biotec contact. Unless otherwise specifically indicated, Miltenyi Biotec products and services are for research use only and not for therapeutic or diagnostic use. MACS, VioBlue, VioGreen, and Vio770 are either registered trademarks or trademarks of Miltenyi Biotec GmbH. Copyright 2012 Miltenyi Biotec GmbH. All rights reserved. Flow cytometry products for 30 tests October Copyright 2012 Miltenyi Biotec GmbH. All rights reserved.
MACS GMP Cytokines Quality to meet your demands
s. Quality to meet your demands deliver performance, consistency, and compliance for demanding applications Superior quality cytokines esigned, produced, tested, and documented to meet high quality standards.
More informationWorkflow for human mesenchymal stem or stromal cells (MSCs)
Workflow for human mesenchymal stem or stromal cells (MSCs) Complete workflow for bone marrow-derived mesenchymal stem or stromal cells (MSCs) 1. Quality control of bone marrow samples with MSC Enumeration
More informationMACSQuant Flow Cytometers Engineering the future of automation
MACSQuant Flow Cytometers Engineering the future of automation At the heart of intelligent design The first MACSQuant Analyzer was engineered to enable demanding and diverse flow cytometry applications
More informationStraightFrom MicroBeads. Cell isolation directly from blood products
StraightFrom MicroBeads Cell isolation directly from blood products MACS Technology A perfect match of MACS Columns and MicroBeads MACS MicroBead Technology is the most trusted and proven cell isolation
More informationMACS GMP Fluorescent Antibodies Facilitating cell manufacturing according to GMP guidelines
MACS GMP Fluorescent Antibodies Facilitating cell manufacturing according to GMP guidelines Ex vivo processing for cell manufacturing MACS GMP Fluorescent Antibodies have been developed for cell labeling.
More informationNatural Killer cell research
Natural Killer cell research Solutions for each step of your workflow From basic to clinical research Research Translational research Clinical Gentle yet effective tissue dissociation MACS Sample Preparation
More informationMACS Cell Separation Directly from whole blood
MACS Cell Separation Directly from whole blood From whole blood straight to leukocyte subsets MACS Products for whole blood just the right tools for fast, reliable cell separation Miltenyi Biotec has developed
More informationThe MACSQuant X Reliable high-throughput flow cytometry
The MACSQuant X Reliable high-throughput flow cytometry Innovative benchtop screening The MACSQuant X has been engineered from the ground up as a compact flow cytometer made to provide maximum speed and
More informationREAfinity Recombinant Antibodies. Flow cytometry is in their genes
REfinity Recombinant ntibodies Flow cytometry is in their genes What are REfinity ntibodies? REfinity ntibodies are recombinantly generated antibodies that provide superior lot-to-lot consistency and purity,
More informationAutomation meets parallel cell separation
MultiMACS Cell Separator Family Automation meets parallel cell separation Standardization & performance Technology that inspires Solutions for pioneering research Miltenyi Biotec offers a complete portfolio
More informationautomacs Pro Separator
automacs Pro Separator Short instructions Version 02 Copyright 2010 Miltenyi Biotec. All rights reserved. No part of this user manual may be reproduced, stored in a retrieval system, transmitted, published,
More informationMultiMACS M Separator
Rapid, multisample biomolecule isolation & processing MultiMACS M Separator 96-well multisample processing Sensitive in-column cdna synthesis Rapid protein isolation Easy isolation of viable viruses Robotic
More informationMACS Cell Separation. Select the best
MACS Cell Separation Select the best MACS Technology One portfolio for all your cell isolation needs MACS Technology enables the magnetic separation of cell populations based on surface antigens. It is
More informationThe MACSQuant Tyto Sorter The revolution in cell sorting has begun
The MACSQuant Tyto Sorter The revolution in cell sorting has begun A leap forward in cell sorting The MACSQuant Tyto is revolutionizing cell sorting. Our patented microchip-based technology opens new possibilities
More informationautomacs Pro Separator Automated gold standard in cell separation
automacs Pro Separator Automated gold standard in cell separation Proven in countless publications Complete automation for walk-away convenience The most advanced technology Experience premium results
More informationUnmatched sensitivity for RNA research
Breaking new grounds with MACS Technology Unmatched sensitivity for RNA research Choose from manual or automated 96-well protocols Save time by sensitive one-step mrna isolation and cdna synthesis Unique
More informationManufacturing dendritic cell products for clinical research. CliniMACS System and MACS GMP Products
Manufacturing dendritic cell products for clinical research CliniMACS System and MACS GMP Products Clinical dendritic cell research Dendritic cell (DC)-based vaccinations in patients aim to modulate an
More informationautomacs Pro Separator The gold standard in automated cell separation
automacs Pro Separator The gold standard in automated cell separation Automate Excite and & Inspire. advance Technology that inspires Complete solutions for pioneering research Miltenyi Biotec offers a
More informationMulticolor flow cytometry analysis of human pluripotent stem cell cultures
Multicolor flow cytometry analysis of human pluripotent stem cell cultures ackground Thorough characterization of pluripotency is mandatory during the establishment of newly derived human embryonic or
More informationefluor Organic Dyes 450/50 BP Fluorescence Intensity Wavelength (nm)
efluor Organic Dyes efluor Organic Dyes Catalog No. Description Clone Application Anti-Mouse efluor 450 Products 48-0042 Anti-mouse CD4 RM4-5 Flow Cytometry 48-0081 Anti-mouse CD8 53-6.7 Flow Cytometry
More informationbulk Great deals! orders! Save on all cytokines and Miltenyi Biotec s EOY12 United Kingdom instrument antibodies! starting kits and separators!
Miltenyi Biotec s End-of-year offers 2012 United Kingdom Great instrument deals! all cytokines and antibodies! bulk orders! starting kits and separators! * Just quote * Select starting kits only; excludes
More informationWelcome to More Choice. Mouse Panels
Welcome to More Choice Mouse Panels Choose from our extensive portfolio of high-quality fluorescent-conjugated reagents to build your multicolor flow cytometry panels. Welcome to a More Colorful World
More informationWe Take the Guesswork Out of Finding the Right Antibody
We Take the Guesswork Out of Finding the Right Antibody Cell isolation and cell culture are essential steps for cutting-edge cell-based research. Screening antibodies shouldn t be. Don t waste valuable
More informationab pdc Subset Phenotyping Kit
ab177772 pdc Subset Phenotyping Kit Instructions for Use A set of antibodies designed to identify pdcs and subsets of pdcs by multi-color flow cytometry. This product is for research use only and is not
More informationRegulatory B Cell Isolation Kit mouse
For further information refer to our website www.miltenyibiotec.com For technical questions, please contact your local subsidiary or distributor. Technical Support Team, Germany: E-mail: macstec@miltenyibiotec.de
More informationBringing custom solutions and contract manufacturing to life
GE Healthcare Bringing custom solutions and contract manufacturing to life Imagined. Delivered. Supported. Custom and bulk solutions Tailored to your precise specifications, our custom products deliver
More informationWelcome to More Choice. Human Panels
Welcome to More Choice Human Panels Choose from our extensive portfolio of high-quality fluorescent-conjugated reagents to build your multicolor flow cytometry panels. Welcome to a More Colorful World
More informationTable S1. Antibodies and recombinant proteins used in this study
Table S1. Antibodies and recombinant proteins used in this study Labeled Antibody Clone Cat. no. Streptavidin-PerCP BD Biosciences 554064 Biotin anti-mouse CD25 7D4 BD Biosciences 553070 PE anti-mouse
More informationMurine and Non-Human Primate Dendritic Cell Targeting Nanoparticles for In Vivo Generation of Regulatory T-Cells
Murine and Non-Human Primate Dendritic Cell Targeting Nanoparticles for In Vivo Generation of Regulatory T-Cells Sebastian O. Stead 1, Svjetlana Kireta 2, Steven James Peter McInnes 3, Francis D. Kette
More informationCD31 MicroBead Kit. for the isolation of human microvascular and umbilical vein endothelial cells (HDMECs, HUVECs) Order no.
Miltenyi Biotec GmbH Friedrich-Ebert-Str. 68 51429 Bergisch Gladbach, Germany Phone: +49 2204 8306-0 Fax: +49 2204 85197 macs@miltenyibiotec.de Miltenyi Biotec Inc. 2303 Lindbergh Street Auburn CA 95602,
More informationDURACLONE IM ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH. For Reseach Use Only - Not for use in Diagnostic procedures
DURACLONE IM ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH Your clinical research trial companion For Reseach Use Only - Not for use in Diagnostic procedures ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH
More informationFlow Cytometry Support Reagents
Excite and inspire Flow Cytometry Support Reagents Introduction Miltenyi Biotec is a leading supplier of flow cytometry products, offering one of the broadest ranges of antibodies, kits, assays, and support
More informationImmobiline DryStrip Visualization of ph gradients
Immobiline DryStrip Visualization of ph gradients 18-1140-60 Immobiline DryStrip as the first di Setting the standard Products from Amersham Pharmacia Biotech set the standard for successful, highly reproducible
More informationStrengthening our flow cytometry portfolio ebioscience antibodies
Brighter conjugates for better discrimination of dim cell populations ebioscience Super Bright antibody conjugates for flow cytometry Strengthening our flow cytometry portfolio ebioscience antibodies At
More informationExtremely good gets even better
Eminent H O M O G E N E O U S F L O O R COVERING VINYL > Wide and fresh range with unique design concept > Non-directional pattern with 3D effect > iq product 3rd generation PUR > No wax, no polish. For
More informationLower spectral overlap. Optimized stain index. Innovative antibodies. Superior multicolor flow cytometry. Violet Laser Reagents: The efluor Solution
Lower spectral overlap Optimized stain index Innovative antibodies Superior multicolor flow cytometry Violet Laser Reagents: The efluor Solution www.ebioscience.com ebioscience provides innovative high
More informationDedicated to Molecular Diagnostics
Dedicated to Molecular Diagnostics For Europe Sample & Assay Technologies QIAGEN s growing role in molecular diagnostics At QIAGEN, one of our key goals is to support clinical decision-making and improve
More informationFRAMEWORK CONVENTION ON CLIMATE CHANGE - Secretariat CONVENTION - CADRE SUR LES CHANGEMENTS CLIMATIQUES - Secrétariat KEY GHG DATA
UNITED NATIONS NATIONS UNIES FRAMEWORK CONVENTION ON CLIMATE CHANGE - Secretariat CONVENTION - CADRE SUR LES CHANGEMENTS CLIMATIQUES - Secrétariat KEY GHG DATA Greenhouse Gas Emissions Data for 1990 2003
More informationPrimePCR Pricing and Bulk Discounts
Assay and Control Bulk Discounts 25% off 5 or more assays Primer Assay Pricing Product Catalog # Description List Price (EUR) Primer Assays (desalted) 10025636 Primer assay desalted, 200 reactions 96 10025637
More informationPrimePCR Pricing and Bulk Discounts
Assay and Control Bulk Discounts 25% off 5 or more assays Primer Assay Pricing Product Catalog # Description List Price (CHF) Primer Assays (desalted) 10025636 Primer assay desalted, 200 reactions CHF
More informationPrimePCR Pricing and Bulk Discounts
Assay and Control Bulk Discounts 25% off 5 or more assays Primer Assay Pricing Product Catalog # Description List Price (DKK) Primer Assays (desalted) 10025636 Primer assay desalted, 200 reactions DKK
More informationRotor-Gene Q quick-start guide
Rotor-Gene Q quick-start guide This guide describes how to set up the Rotor-Gene Q. Before using the Rotor-Gene Q, it is essential that you read the Rotor-Gene Q User Manual carefully and pay particular
More informationBio-Plex Pro Mouse Cytokine, Chemokine, and Growth Factor Assays
Acute Phase Response Cancer Cardiovascular Disease Cytokine, Chemokines, Growth Factors Diabetes Gene Expression Genotyping Immunoglobulin Isotyping MicroRNA Expression Signal Transduction Toxicology Bio-Plex
More informationSupplementary Figure 1. Effect of FRC-specific ablation of Myd88 on PP and mln organization.
Supplementary Figure 1 Effect of FRC-specific ablation of Myd88 on PP and mln organization. (a) PP numbers in 8 10 week old Cre-negative littermate (Ctrl) and Myd88-cKO mice (n = 11 mice; each dot represents
More informationWhat is the first step in moving from reactive maintenance to predictive maintenance?
UTILIZING DYNAMIC SCHEDULING IN A PREDICTIVE MAINTENANCE WORLD KEY QUESTIONS: P3 How do advanced scheduling, predictive maintenance and Internet of Things link together? P4 What is the first step in moving
More informationApplication Note. Thin metal foils with coatings. Sample Preparation for SEM. related instrument Leica EM RES102.
Material Life Science Application Note Thin metal foils with coatings Sample Preparation for SEM related instrument Leica EM RES102 Medical Industrial Manufacturing Natural Resources 2 Ion beam slope cutting
More informationConvenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF
GE Healthcare Convenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF M. Carlsson, A. Heijbel, and A-C. Häggqvist GE Healthcare AB, Björkgatan 3, SE-751 84 Uppsala, Sweden Abstract
More informationThe RT-qPCR analysis of selected type-i IFNs related genes, IRF7 and Oas3. The
SUPPLEMENTARY MATERIALS AND METHODS Real time quantitative PCR The RT-qPCR analysis of selected type-i IFNs related genes, IRF7 and Oas3. The RT-qPCR was performed on the Applied Biosystems StepOne TM
More informationBio-Plex Pro Mouse Cytokine, Chemokine, and Growth Factor Assays
Acute Phase Response Cancer Cardiovascular Disease Cytokine, Chemokines, Growth Factors Diabetes Gene Expression Genotyping Immunoglobulin Isotyping MicroRNA Expression Signal Transduction Toxicology Bio-Plex
More informationProduct Catalog # Description List Price (JPY) Primer Assays (desalted)
Assays and Controls Primer Assay Pricing Primer Assays (desalted) 10025636 Primer assay desalted, 200 reactions 16,000 (Wet-lab validated human, mouse, and rat) 10025637 Primer assay desalted, 1,000 reactions
More informationMicrosoft Dynamics 365 Business Central. Licensing Guide - Simplified. May 2018
Microsoft Dynamics 365 Business Central Licensing Guide - Simplified May 2018 Source: https://mbs.microsoft.com/files/public/365/dynamics365businesscentrallicensingguide.pdf Created by: ABC E BUSINESS
More informationNew Linoleum xf LINOLEUM
New Linoleum xf A S U R FAC E R E V O L U T I O N L I N O L E U M extremely strong surface protection excellent resistance to abrasion, stains and chemicals no initial wax or polish needed no need to strip
More information2008 Year-in-Review Benchmarks
research research report June 2009 2008 Year-in-Review Benchmarks learn more Looking for more DoubleClick research? Check out www.doubleclick.com/knowledge Executive Summary... 1 Static Image Ad Benchmarks...
More informationDow Liquid Separations. The UPCORE System. Upflow Countercurrent Regeneration System. Reference Plants
Dow The UPCORE System Upflow Countercurrent Regeneration System Reference Plants UPCORE* SYSTEM REFERENCE LIST 1 1978 METAL PROCESSING AND MINING NETHERLANDS D R SAC-LBA 2 100 2 1982 SUGAR AND FOOD PROCESSING
More informationDetailed Data from the 2010 OECD Survey on Public Procurement
ANNEX G Detailed Data from the 2010 OECD Survey on Public Procurement This annex provides data for each responding country on the transparency of the public procurement cycle, as well as the online availability
More informationMagnetic drive pumps YMD series
PDF-E 0018-05 Magnetic drive pumps YMD series Stainless steel magnet pumps with compact size and simple structure The YMD series comprises of stainless steel magnetic drive pumps that have been jointly
More informationNew Linoleum xf. linoleum. A Surface Revolution
New Linoleum xf A Surface Revolution linoleum extremely strong surface protection excellent resistance to abrasion, stains and chemicals no initial wax or polish needed no need to strip easy cleaning and
More informationAvidin/Biotin Blocking Kit
Version 1 Last updated 25 June 2018 ab64212 Endogenous Avidin/Biotin Blocking Kit For the blocking of endogenous biotin during immunohistochemistry. This product is for research use only and is not intended
More informationGlobal Commerce Review EMEA, Q2 2018
Global Commerce Review EMEA, Q2 2018 Mobile Marches On In APAC, Mobile now accounts for the majority of transactions Europe North America Middle East & Africa Asia Pacfic Latin America 2 Source: Criteo,
More informationSelecting Reagents for Multicolor Flow Cytometry
HotLines Platinum Edition f a l l 0 0 6 Selecting Reagents for Multicolor Flow Cytometry By Holden Maecker and Joe Trotter The availability of flow cytometers capable of detecting 6, 8, and more colors
More informationHybriScan I Candida albicans
HybriScan I Candida albicans The rapid and innovative test system for the identification of Candida albicans Product-No.: 19503 Deutsche Version der Anleitung siehe unter www./hybriscan Contact information:
More informationSupplementary Figure 1 (Page1)
Supplementary Figure 1 (Page1) A B FSC-A 45 Fitc-A 133 APC-A 19 APC-Cy7-A 34 PE-A 45 Fitc-A FSC-A 45 Fitcs-A C 38 PE-Cy7-A 45 Fitc-A 45 Fitc-A 7AAD FSC-A Supplementary Figure 1 (Page2) D (1) (6) (2) (3)
More informationHybriScan I Lactobacillus brevis
HybriScan I Lactobacillus brevis The rapid and innovative test system for the identification of Lactobacillus brevis Product-No.: 75724 Deutsche Version der Anleitung siehe unter www.sigma-aldrich.com/hybriscan
More informationRFID Systems Radio Country Approvals
SIMATIC Ident RFID Systems Radio Approvals 2017-12-17 www.siemens.com/ident Short Range Systems RF200 RF300 RF1060 MOBY D RF210R / RF220R 6GT2821-1AC10,-2AC10 RF210R / RF220R / RF240R/ RF250R/ RF260R IO-Link
More informationCable and pipe seals. for Buildings/Constructions
Cable and pipe seals for Buildings/Constructions When safety matters Roxtec is the market leader in the modularbased sealing industry. Our solutions for cables and pipes help to add safety and reliability
More informationAPPLICATION Additive in polypropylene-compatible systems. TYPICAL PROPERTIES DESCRIPTION
Product Information Plastics DOW CORNING MB5 2 Masterbatch FEATURES Imparts processing improvements and modified surface characteristics BENEFITS Improved throughput Reduced energy consumption Enhanced
More informationFrom Government-driven to Citizen-centric Public Service Delivery
From Government-driven to Citizen-centric Public Service Delivery Haiyan Qian Director Division for Public Administration and Development Management Department of Economic and Social Affairs, United Nations
More informationREPORT. State of the Nation Report landfilling practices and regulation in different countries. December, 2012
REPORT State of the Nation Report landfilling practices and regulation in different countries December, 2012 ISWA the International Solid Waste Association is a global, independent and non-profit making
More informationHybriScan I Pectinatus cerevisiiphilus
HybriScan I Pectinatus cerevisiiphilus The rapid and innovative test system for the identification of Pectinatus cerevisiiphilus Product-No.: 89384 Deutsche Version der Anleitung siehe unter www.sigma-aldrich.com/hybriscan
More informationWHITE PAPER 5 TIPS FOR MANAGING FOOD AND BEVERAGE SUPPLY CHAIN
WHITE PAPER 5 TIPS FOR MANAGING FOOD AND BEVERAGE SUPPLY CHAIN CONTENT AUTOMATE, AUTOMATE, AUTOMATE... 1 PLAN FOR FUTURE DEMAND... 2 MAINTAIN DETAILED REGULATORY COMPLIANCE DATA... 3 CONTROL COSTS BY MINIMIZING
More informationGlobal Commerce Review. Americas, Q2 2018
Global Commerce Review Americas, Q2 2018 Mobile Share of Transactions Mobile continues to steal share, driven by an increase in smartphone transactions Sales by Device, Q2 2017 and Q2 2018, United States,
More informationThe Cost of the Kyoto Protocol: Moving Forward on Climate Change Policy While Preserving Economic Growth
The Cost of the Kyoto Protocol: Moving Forward on Climate Change Policy While Preserving Economic Growth Dr. Margo Thorning Managing Director, International Council for Capital Formation Brussels Office:
More informationWORKFORCE METRICS BENCHMARK REPORT
WORKFORCE METRICS BENCHMARK REPORT THE MORE YOU KNOW, THE SMARTER YOU WORK As an HR professional, you focus on helping your organization optimize its human capital, but how do you show that achievement?
More informationMACSPlex mirna Kit Cancer
For further information refer to our website www.miltenyibiotec.com For technical questions, please contact your local subsidiary or distributor. Technical Support Team, Germany: Phone +49 2204 8306-830
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 3850 First edition 2004-04-01 Resilient floor coverings Determination of apparent density of composition cork Revêtements de sol résilients Détermination de la masse volumique
More informationdefense manufacturers
IFS Applications for defense manufacturers OUR SOLUTION S DNA When we first set out to create IFS Applications over 25 years ago, our goal was to make the most usable business solution on the market. And
More informationUmbilical Cord Dissociation Kit human
Umbilical Cord Dissociation Kit human Order no. 130-105-737 Contents 1.1 Principle of the Umbilical Cord Dissociation Kit 2. Protocols 2.1 Reagent preparation 2.2 Umbilical cord dissociation protocol 2.2.1
More informationAccelerate cell line development. Get to your high value hits faster
Accelerate cell line development Get to your high value hits faster Transform your workflows to elevate productivity Fast screening and selection of secretory cell lines with ClonePix Systems Screen 10x
More informationGlobal Energy Production & Use 101
Global Energy Production & Use 101 Jean-Sébastien Rioux The School of Public Policy SPP-HEI Summer School on the Geopolitics of Energy & Natural Resources Calgary, AB May 15-20, 2017 Presentation highlights
More informationSelecting a cross flow cartridge
GE Healthcare 18-1165-31 AC Membrane separations Selecting a cross flow cartridge Four key questions To ensure your separations process operates successfully and efficiently, you must select the proper
More informationYalin Emre, Magali Irla, Isabelle Dunand- Sauthier, Romain Ballet, Mehdi Meguenani, Stephane Jemelin, Christian Vesin, Walter Reith and Beat A.
Supplementary information Thymic epithelial cell expansion through matricellular protein CYR61 boosts progenitor homing and T- cell output Yalin Emre, Magali Irla, Isabelle Dunand- Sauthier, Romain Ballet,
More informationGasification of Biomass and Waste Recent Activities and Results of IEA Bioenergy Task 33
Gasification of Biomass and Waste Recent Activities and Results of IEA Bioenergy Task 33 Presentation made by: Berend Vreugdenhil (ECN, Netherlands) Presented by: Timo Gerlagh (RVO.nl, Netherlands) Beijing,
More informationGlobal Engagement on Nano EHS: Role of the OECD in International Governance
Global Engagement on Nano EHS: Role of the OECD in International Governance Jeff Morris National Program Director for Nanotechnology www.epa.gov/nanoscience Amherst, MA 24 September 2010 State of Play:
More informationReagents Catalog 10 th Edition Human Mouse Non-Human Primate
Welcome to More Choice Multicolor Antibody Reagents Catalog 10 th Edition Human Mouse Non-Human Primate Choose from our extensive portfolio of high-quality fluorescent-conjugated reagents to build your
More informationReagents Catalog 10 th Edition Human Mouse Non-Human Primate
Welcome to More Choice Multicolor Antibody Reagents Catalog 10 th Edition Human Mouse Non-Human Primate Choose from our extensive portfolio of high-quality fluorescent-conjugated reagents to build your
More informationApplication Note USD Purification of Mouse IgM from Cell Culture Supernatant by Cation Exchange Chromatography on CM Ceramic HyperD F Sorbent
Application Note USD 241 Purification of Mouse IgM from Cell Culture Supernatant by Cation Exchange Chromatography on CM Ceramic HyperD F Sorbent What this Study Demonstrates T h i s s t u d y o n C a
More informationMICRO DIAPHRAGM GAS SAMPLING PUMPS
MICRO DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET E 004 NMP 05 S NMP 09 M NMP 015 B Concept The micro diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its
More informationIWAKI MAGNETIC DRIVE GEAR PUMPS MDG
IWAKI MAGNETIC DRIVE GEAR PUMPS Compact gear pumps that completely eliminate Iwaki Series pumps are small seal-less magnetic drive gear pumps engineered to provide the utmost in quiet and leak-free operation.
More informationRefractor y Systems Anchoring Systems
Refractor y Systems Anchoring Systems Left: Schematic diagram of a ceiling construction with Steuler anchoring bricks in a monolithic lining. STEULER-KCH also supplies the relevant holding clamps for the
More informationIFS APPLICATIONS. Asset AGILE SOLUTIONS IN ACTION
1 IFS APPLICATIONS Asset Management AGILE SOLUTIONS IN ACTION SEADRILL 5 NHPC 7 HAFSLUND ASA 9 THREE GORGES HYDROPOWER PLANT SSAB 13 SCA GRAPHIC SUNDSVALL 15 11 3 Turning challenges into profits Modern
More informationFemale 6-7-week-old BALB/c mice were purchased from Japan SLC (Hamamatsu, Japan).
Supplementary materials Materials and Methods Mice Female 6-7-week-old BALB/c mice were purchased from Japan SLC (Hamamatsu, Japan). All mice were maintained under specific pathogen free conditions, and
More information5 REASONS TEKTRONIX OSCILLOSCOPES ARE RELIABLE AND TRUSTED TECHNICAL BRIEF
5 REASONS TEKTRONIX OSCILLOSCOPES ARE RELIABLE AND TRUSTED TECHNICAL BRIEF 5 REASONS TEKTRONIX OSCILLOSCOPES ARE RELIABLE AND TRUSTED TECHNICAL BRIEF The Tektronix TBS1000, TBS2000, and MSO/DPO2000 oscilloscopes,
More informationBD Biosciences Research Reagents Mouse (featuring BD Pharmingen products) Product List - October 2011 Valid in The United Kingdom
BD Biosciences Research Reagents Mouse (featuring BD Pharmingen products) Product List - October 2011 Valid in The United Kingdom Abbreviations APC Allophycocyanin APC-Cy 7 Allophycocyanin-cyanin 7 APC-H7
More informationPROJECT - CHECKLIST FOR BRICKWORK FAÇADES FM
06/08 Page 2/5 Information about the project: Project: Location: Street HALFEN Project No.: ICT-No.: ZIP Code Town Offer Customer: Request Order Fee charge for engineering Trade Industry Company: Contractor:
More informationIsolation and cultivation of astrocytes from adult mouse brain
Isolation and cultivation of astrocytes from adult mouse brain Contents 1. Description 1.1 Background information 1.2 Reagent and instrument requirements 2. Protocol 2.1 Preparation of brain dissociation
More informationCD1a-autoreactive T cells are a normal component of the human αβ T cell repertoire
CDa-autoreactive T cells are a normal component of the human αβ T cell repertoire Annemieke de Jong, Victor Peña-Cruz, Tan-Yun Cheng, Rachael A. Clark, Ildiko Van Rhijn,, D. Branch Moody Division of Rheumatology,
More informationWorking together to meet global energy challenges
Working together to meet global energy challenges Staff on loan From around the world From IEA and OECD member countries: Australia Austria Belgium Canada Chile Czech Republic Denmark Estonia Finland France
More informationIn vivo BrdU Incorporation Assay for Murine Hematopioetic Stem Cells Ningfei An, Yubin Kang *
In vivo BrdU Incorporation Assay for Murine Hematopioetic Stem Cells Ningfei An, Yubin Kang * Division of Hematology-Oncology, Department of Medicine, Medical University of South Carolina, Charleston,
More informationWhere valuable assets are at risk. Type approvals
Where valuable assets are at risk Type approvals Our products are tested and certified by a long list of customers, laboratories and certification organisations. MCT Brattberg Tested, developed and certified.
More informationEROWA Robot System Linear
EROWA Robot System Linear Several machines flexibly linked System solutions from one single source EROWA Robot System Linear Linear service optimal use Would you like to use your Robots to a higher capacity?
More information