Dräger SmartPilot View Software visualisation of anaesthetic levels
|
|
- Donna Willis
- 6 years ago
- Views:
Transcription
1 Dräger SmartPilot View Software visualisation of anaesthetic levels SmartPilot View provides innovative state-of-the-art modelling technology and a comprehensive visualisation concept of complex drug effects to display current and predicted anaesthesia levels. This intuitive display provides support at all phases of anaesthesia.
2 02 Dräger SmartPilot View Benefits Comprehensive visualisation SmartPilot View uses widely accepted patient models to calculate and visualise pharmacokinetic and pharmacodynamic information and displays the calculated anaethesia level. At the same time it displays the most important hemodynamic parameters to support the intuitive and fast compilation of patient status at a glance. Extensive medical knowledge database SmartPilot View features an extensive database of pharmacokinetics and pharmacodynamic patient models. Thanks to the visualisation of this knowledge base on SmartPilot View, the anaesthesiologist has instant access to the information. Process optimisation SmartPilot View addresses the main challenges of the anaesthesia process by helping you to perform smooth induction, maintain adequate anaesthesia levels and a well-timed, painless wake-up of the patient. Thanks to SmartPilot View, already during drug administration, the anaesthesiologist can visualise the calculated current anaesthesia level and the expected course of anaesthesia at a glance. This can facilitate the optimization of anaesthesia application and analgesia management. SmartPilot view simplifies the estimation of individual drug dosing. Designed for Primus and Zeus Anaesthesia Workstations Platforms and Perseus A 500 The SmartPilot View is designed to be combined with Primus, Primus Infinity Empowered, Perseus A500, Zeus and Zeus Infinity Empowered and can automatically transfers various data from these anaesthesia workstations. When used in conjunction with Zeus Infinity Empowered, the "what if" function will display the calculated effect of setting change of anaesthesia level even before the setting is confirmed. Common features Runs on Dräger Infinity C700 for IT and on other medical-grade PCs Easy accessibility via application view tabs (only in combination with Infinity Explorer) Prediction of anaesthesia level, based on pharmacokinetics and pharmacodynamics Editable drug database Data transfer of compatible syringe pump settings (see technical data for compatibility information) Specific features in combination with Dräger Anaesthesia Workstations Primus Infinity Empowered: Automatic data transfer of measured ventilation and gas concentration values Perseus A500: Automatic transfer of Vapor 3000 hand dial settings as well as measured ventilation and gas concentration values
3 Dräger SmartPilot View 03 Benefits Zeus Infinity Empowered: Prediction based on automatically transferred settings, measured values and drug configurations; What if function System Components Infinity Acute Care System D Transform your clinical workflow with Infinity Acute Care System. Its multiparameter monitor integrates with its networked medical-grade workstation, giving you real-time vital signs, access to clinical hospital systems and data management applications for a comprehensive range of patient information and powerful analysis tools at the point-of-care. Infinity Omega Solution MT This two-screen solution provides access to images, lab results and other clinical data, while displaying real-time vital signs data at the point of care on a 20" touchscreen. Bedside/transport monitor continuously monitors patient during transport and at the bedside.
4 04 Dräger SmartPilot View Technical Data SmartPilot View Software version Classification Classification in accordance with Directive 93/42/EEC Annex IX 3.0n Class IIb General SmartPilot View displays pharmacokinetic, pharmacodynamic (PK/PD) modelling information for use with total intravenous (TIVA), balanced anaesthesia and volatile anaesthesia. Display of haemodynamic measurements and processed EEG (BIS Aspect). Drug and dosage data entry for intravenous drugs: manually or automatically from the syringe pumps. For inhaled anaesthetics: automatically from anaesthesia device. Event markers allow the patient s individual status to be documented with regard to the observed anaesthesia level. The markers may be deleted or repositioned if needed. Support of USB stick for case recording. Editable drug database. PK/PD models Interaction between volatile and intravenous hypnotics and opioids visualised through two-dimensional graph with 15 minute prediction. PK models for each single drug visualised in a time-based graph with 40 minute trend and 20 minute prediction. Manual entry of drug bolus and rates at current time or retrospectively followed by recalculation of the case, incl. prediction. PK models Propofol Schnider Alfentanil Scott Remifentanil Fentanyl Sufentanil Volatiles Pancuronium Rocuronium Vecuronium Mivacurium PD models Sequential model Minto Scott Gepts Bailey Rupp Wierda Cronnelly Laurin Bouillon *Supported drugs Hypnotics: Volatile drugs Desflurane, Isoflurane, Sevoflurane Opioids (intravenous) Fentanyl, Remifentanil, Alfentanil, Sufentanil Intravenous drugs Muscle relaxants* Propofol Pancuronium, Rocuronium, Mivacurium, Vecuronium *The impact of muscle relaxants on the drug interaction is not taken into account. Patient demographic data Height cm (59.1 to 78.7 in) Age years Weight Body mass index (BMI) kg (89 to 308 lbs) <= 35 ASA Level < IV The limitations of the patient demographic data are due to the calculation of lean body mass using the formula from James [James WPT. Research on obesity. London. Her Majesty s Stationery Office. (ISBN ). 1976].
5 Dräger SmartPilot View 05 Technical Data System compatibility Anaesthesia devices Zeus, Zeus IE, Perseus A500, Primus, Primus IE Monitoring Dräger Infinity Delta, Dräger Infinity Delta XL, Dräger Zeus / PC-platform Dräger C700 for IT with or without Infinity Explorer or other medical-grade PC (system requirements: W7 32/64bit 1-GHz-CPU (x86 x64) 1 GB RAM (at least 500 MB available RAM at startup of SPV) 1 GB available Hard Disk Drive space Screen resolution: 1,280 x 768 Zeus Infinity Empowered with integrated haemodynamic monitoring, IACS patient monitor, Philips monitor (MP50, MP70, MX800) Display of patient measurements and processed EEG (BIS Aspect) provided by the basic device: Heart rate 1/min etco2 mmhg or kpa Blood pressure (ART M or NIBP) BIS Index and SQI Infusion pumps mmhg or kpa Dräger IVenus** Fresenius Orchestra Modul DPS with Base A B. Braun Fresenius Fresenius Alaris Terumo Terumo Perfusor Space with SpaceCom** Orchestra Modul DPS with Base Primea* Injectomat Agilia with Link Agilia GH, PK*, TIVA with Gateway Terumo Terufusion TE-332, TE-371, TE-372 Terumo Terufusion TE-SS800 with TE-RS800 Range of supported devices (e.g. Patient Monitors, Anaesthesia devices and infusion pumps) is expanding: please contact your Dräger representative for the current list of compatible devices. *TCI pumps are supported **up to four infusion pumps Perfusor Space with SpaceCom is the registered trade mark of Company B.Braun. Orchestra Modul DPS with Base A, Orchestra Modul DPS with Base Primea and Injectomat Agilia with Link Agilia are registered trade mark of Company Fresenius. Terumo Terufusion TE-332, TE-371, TE- 372 and Terumo Terufusion TE-SS880 with TE-RS800 are registered trade mark of Company Terumo.
6 06 Dräger SmartPilot View Notes
7 Dräger SmartPilot View 07 Notes
8 08 Dräger SmartPilot View Communications & Sales Marketing PP LE Chlorine-free environmentally compatible Subject to modifications 2016 Drägerwerk AG & Co. KGaA Notes CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee Lübeck, Germany Manufacturer: Drägerwerk AG & Co. KGaA Moislinger Allee Lübeck, Germany Locate your Regional Sales Representative at: REGION EUROPE CENTRAL AND EUROPE NORTH REGION MIDDLE EAST, AFRICA Drägerwerk AG & Co. KGaA Moislinger Allee Lübeck, Germany Tel Fax info@draeger.com Drägerwerk AG & Co. KGaA Branch Office P.O. Box Dubai, United Arab Emirates Tel Fax contactuae@draeger.com REGION EUROPE SOUTH REGION ASIA / PACIFIC Dräger Médical S.A.S. Parc de Haute Technologie d'antony 2 25, rue Georges Besse Antony Cedex, France Tel Fax dlmfr-contact@draeger.com Draeger Medical South East Asia Pte Ltd. 25 International Business Park #04-27/29 German Centre Singapore , Singapore Tel Fax asia.pacific@draeger.com REGION CENTRAL AND SOUTH AMERICA Dräger Panama Comercial S. de R.L. Complejo Business Park, V tower, 10th floor Panama City Tel Fax contactcsa@draeger.com
Dräger Mounting System Medical Supply Units
Dräger Mounting System Medical Supply Units Appealing in design, the flexible Dräger Mounting System provides ergonomic positioning in emergency rooms, operating theatres, intensive care units and other
More informationDräger Jaundice Meter JM-105 Jaundice Management
Dräger Jaundice Meter JM-105 Jaundice Management The Dräger Jaundice Meter JM-105 gives you consistent quality screening, cost-effectively delivered over the lifetime of the device. As a result you optimize
More informationDräger MSI Variox-2 Combustion Gas Analysis
Dräger MSI Variox-2 Combustion Gas Analysis Single gas analyzer in seven versions: The Dräger MSI VARIOx-2 is a complete family of electronic single gas analysis devices for measuring gas concentrations
More informationDräger CSE Connect Software
Dräger CSE Connect Software The Dräger CSE Connect software solution digitises the exchange of information during clearance measurement procedures The data transfer between the smartphone app and web application
More informationDRÄGER SERVICES. On-site Safety Service
DRÄGER SERVICES On-site Safety Service Manage safety-related processes with a belt and braces approach that s what Dräger On-site Safety Service offers. RENÉ KRÜGER PROJECT COORDINATOR 04 Directly on-site
More informationOn-site & Shutdown Safety Service Project Coordinator / Project Manager. Basic Information
On-site & Shutdown Safety Service Project Coordinator / Project Manager When it comes to turnarounds or other safety-critical tasks, our Project Coordinators / Project Managers plan the operative use of
More informationDRÄGER SERVICES. Product Service
DRÄGER SERVICES Product Service Is your team ready for any deployment? Your equipment should be as well. ALBERT SCHERER SERVICE TECHNICIAN 04 05 Full operational readiness You entrust our products with
More informationProduct Service Remote Service. Basic Information
Product Service Remote Service With remote service, problems can be detected and analysed quickly even at remote locations. This gives medical systems optimal availability. Status reports help to both
More informationOn-site & Shutdown Safety Service Safety Observer
On-site & Shutdown Safety Service Safety Observer Our Safety Observers support you in all matters regarding health and safety at work. They observe processes and suggest measures which can be implemented
More informationD The tools you need, wherever you need them DRÄGER SUPPLY UNITS
D-18884-2010 The tools you need, wherever you need them DRÄGER SUPPLY UNITS 02 DRÄGER SUPPLY UNITS D-30796-2011 Dräger supply units put anything you need to work effectively within easy reach at all times.
More informationDräger DrugTest 5000 Drug Screening Device
Dräger DrugTest 5000 Drug Screening Device No pipetting, no drips, no timing: Collecting an oral fluid sample is quick and easy with the Dräger DrugTest 5000. The collected sample can then be analysed
More informationPerformance Overview Calibration of your devices according to use instructions, including test gas at our Dräger workshop or directly on-site.
Product Service Calibration Care Precise measurements available anytime, anywhere: Calibration Care ensures that your measuring devices continue providing the most accurate data possible. Our technicians
More informationOn-site & Shutdown Safety Service Safety Equipment Technician. Basic Information
On-site & Shutdown Safety Service Safety Equipment Technician In the Safety Shop or in your workshop, the Safety Equipment Technician is responsible for ensuring that the necessary safety equipment is
More informationDrägerware Workshop Software 5000/7000 Drägerware Software
Drägerware Workshop Software 5000/7000 Drägerware Software Simply better organised: With its extraordinary degree of flexibility, Drägerware Workshop software is the ideal complete solution for workshop
More informationAn Innovative Web Services-Based Architecture for Distributed Systems of Medical Devices
An Innovative Web Services-Based Architecture for Distributed Systems of Medical Devices The interoperability capabilities of today s acute care devices are not always able to address the future needs
More informationDräger Fumigation Test Set Dräger-Tubes
Dräger Fumigation Test Set Dräger-Tubes The Dräger-Tube measurement system provides an easy method for testing containers and other spaces for the presence of fumigation agents A specially developed measuring
More informationMiraCradle an affordable solution for developing countries
MiraCradle MiraCradle is an affordable cooling device to induce therapeutic hypothermia among newborns suffering from birth asphyxia. It is easy to use, safe, light weight, portable and gives the precise
More informationMovita systems Medical Supply Units
Movita systems Medical Supply Units The Movita ceiling supply unit has an especially high load capacity and a wide range of configurations to choose from, so it offers virtually unlimited horizontal and
More informationDräger DrugTest 5000 Drug Testing Device
Dräger DrugTest 5000 Drug Testing Device No pipetting, no drips, no timing: With the Dräger DrugTest 5000, a drug test is carried out simply and quickly. The collected saliva samle can be analyzed immediately
More informationDrägerware.Workshop Software 5000/7000 Drägerware Software
Drägerware.Workshop Software 5000/7000 Drägerware Software D-3417-2019 Simply better organised: With its extraordinary degree of flexibility, Drägerware Workshop software is the ideal complete solution
More informationDräger EM200 Multi-channel analyser for measuring flue gases
Dräger EM200 Multi-channel analyser for measuring flue gases Combustion produces flue gases and high concentrations of these flue gases can be harmful to humans and the environment. The Dräger EM200 helps
More informationTIVA and Smart Pumps: TCI systems. TIVA and Smart Pumps: TCI systems. TCI: What is it 9/22/2012
TIVA and Smart Pumps: TCI systems TIVA and Smart Pumps: TCI systems P.L. Gambús Visiting Associate Professor Department of Anesthesia & Perioperative Care UCSF P.L. Gambús Consultor Departament de Anestesiologia
More informationAn Innovative Web Services-Based Architecture for Distributed Systems of Medical Devices
An Innovative Web Services-Based Architecture for Distributed Systems of Medical Devices The interoperability capabilities of today s acute care devices are not always able to address the future needs
More informationDräger Jaundice Meter JM-105 Jaundice Management
Dräger Jaundice Meter JM-105 Jaundice Management The Dräger Jaundice Meter JM-105 gives you consistent quality screening, cost-effectively delivered over the lifetime of the device. As a result, you optimize
More informationDräger DrugTest 5000 Analysis system for detecting drugs
Dräger DrugTest 5000 Analysis system for detecting drugs No pipetting, no dripping, no timing: Not only sampling is done quickly and easily with the Dräger DrugTest 5000. Directly afterwards, the sample
More informationDevices for Target-Controlled Drug Infusion
The Development and Regulation of Commercial 2 Devices for Target-Controlled Drug Infusion John B. Glen Introduction The mathematical background to the concept of targetcontrolled infusion (TCI) and its
More informationSAFETY ACTION NOTICE By arrangement with the Scottish Government Health Directorates
SAFETY ACTION NOTICE By arrangement with the Scottish Government Health Directorates CARDINAL HEALTH (ALARIS) PK INFUSION PUMP TCI SOFTWARE: RISK OF OVER/UNDER INFUSION OF OBESE PATIENTS SUMMARY Page 1
More informationThis electronic thesis or dissertation has been downloaded from the King s Research Portal at
This electronic thesis or dissertation has been downloaded from the King s Research Portal at https://kclpure.kcl.ac.uk/portal/ Modelling and Control Techniques for Patient General Anaesthesia Novais Carvalho
More informationDrug Interaction Between Propofol and Remifentanil in Individualised Drug Delivery Systems
Preprints of the 9th IFAC Symposium on Biological and Medical Systems The International Federation of Automatic Control Drug Interaction Between Propofol and Remifentanil in Individualised Drug Delivery
More informationResearch Data Management Scientific integrity & Societal value. Prof. Dr. Meindert Danhof
Research Data Management Scientific integrity & Societal value Prof. Dr. Meindert Danhof Leiden Academic Centre for Drug Research mission & objectives LACDR is one of the leading academic centres in learning,
More informationST D D Planning Documents for OR
D-76332-2013 ST-8934-2008 D-85565-2013 Planning Documents for OR PLANNING DOCUMENTS FOR OR PREAMBLE 3 Preamble This Planning Document was developed to enhance your knowledge of the Dräger portfolio and
More informationPharmacokinetic-pharmacodynamic modeling in anesthesia
International Congress Series 1220 (2001) 89-97 Pharmacokinetic-pharmacodynamic modeling in anesthesia Pedro L. Gambus a '*, Haiti F. Troconiz b ^Department of Anesthesiology, CLINIC Hospital Umversitari,
More informationAutomated Total IntraVenous Anesthesia (amtiva) from induction to recovery
Automated Total IntraVenous Anesthesia (amtiva) from induction to recovery Luis A. Paz, Margarida M. Silva, Simão Esteves, Rui Rabiço, Teresa Mendonça Dep. Matemática, Fac. Ciências, Universidade do Porto,
More informationIJBCP International Journal of Basic & Clinical Pharmacology. Review of pharmacokinetic models for target controlled infusions in anesthesia
Print ISSN 2319-2003 Online ISSN 2279-0780 IJBCP International Journal of Basic & Clinical Pharmacology doi: 10.5455/2319-2003.ijbcp20140601 Review Article Review of pharmacokinetic models for target controlled
More informationD D DrägerService Quality products deserve quality service
01 D-57148-2012 D-6715-2014 DrägerService Quality products deserve quality service 02 DRÄGERSERVICE Dräger: your single source for products, service and rental management Superior Products Inspection,
More informationSPECTRA OPTIA APHERESIS SYSTEM
Unlocking the Potential of Blood SPECTRA OPTIA APHERESIS SYSTEM Advancing therapeutic apheresis and cell collections to the next level of patient care ADVANCED TECHNOLOGY THAT GIVES YOU CHOICE AND PRECISION
More informationTarget Controlled Infusions
09 September 2011 No. 31 Target Controlled Infusions D Naidoo Commentator: C Alphonsus Moderator: C Evans Department of Anaesthetics CONTENTS INTRODUCTION... 3 DEFINITION OF TARGET CONTROLLED INFUSIONS...
More informationDrägerwerk AG & Co. KGaA Analysts' Meeting Frankfurt, March 12, 2013
Image H 9.4 cm x W 27.53 cm Drägerwerk AG & Co. KGaA Analysts' Meeting Frankfurt, March 2, 203 Disclaimer This presentation does not constitute an offer of securities for sale or a solicitation of an offer
More informationSoftware Solution. Get the data where and when you need it.
Software Solution Get the data where and when you need it. Software Solution TEG Manager was developed to help clinicians manage a patient s hemostasis by providing easy access to test information through
More informationAmendment No. 1. Paperless Critical Care and Anaesthesia Solution
Amendment. 1 Sub: Amendment to the Bidding Document 24-11-2017 Ref.: tice Inviting Bid ref. HITES/PCD/NCI-AIIMS/05/17-18 dated 08.11.2017 The following changes have been authorised and are being incorporated
More informationROBOTIC ANESTHESIA A VISION FOR THE FUTURE OF ANESTHESIA
ROBOTIC ANESTHESIA A VISION FOR THE FUTURE OF ANESTHESIA Thomas M Hemmerling, MSc, MD, DEAA, Riccardo Taddei,* MD, Mohamad Wehbe, MSc, Joshua Morse, Shantale Cyr, PhD, Cedrick Zaouter,* MD Departments
More informationNetworked intermediate care
Networked intermediate care IntelliVue MP40 and MP50 patient monitors Connected to more The IntelliVue family of networked patient monitors gives care teams throughout the hospital more of the information
More informationHigh-intensity performance. IntelliVue MP80 and MP90 patient monitors
High-intensity performance IntelliVue MP80 and MP90 patient monitors See a higher level The IntelliVue family of networked patient monitors gives care teams throughout the hospital more of the information
More informationCODE-STAT 9.0 DATA REVIEW SOFTWARE PRODUCT BROCHURE
CODE-STAT 9.0 DATA REVIEW SOFTWARE PRODUCT BROCHURE More powerful post-cardiac-event review. Improved performance. A higher level of care. 1 CODE-STAT 9.0 Improvement. Fueled by information. New CODE-STAT
More informationPrinciples of total intravenous anaesthesia: basic pharmacokinetics and model descriptions
BJA Education, 16 (3): 92 97 (2016) doi: 10.1093/bjaceaccp/mkv021 Advance Access Publication Date: 8 June 2015 Matrix reference 1A02, 3I00 Principles of total intravenous anaesthesia: basic pharmacokinetics
More informationi 4 imm Critical Care Monitor GE Healthcare Modular monitoring for critical care
GE Healthcare i 4 Modular monitoring for critical care imm Critical Care Monitor imm imm Critical Care Monitor the power of modularity iconnect i 4 ipon icentral imm the innovative, intuitive, integrated
More informationMonitoring and Control in Anaesthesia: an Implementation Example
Case Study: Depth of Anaesthesia (DOA) Anaesthesia includes paralysis, unconsciousness (i.e. DOA) and analgesia; Monitoring and Control in Anaesthesia: an Implementation Example Catarina S. Nunes Department
More informationTechnical Compendium CDI. Blood Parameter Monitoring System 500
Technical Compendium CDI Blood Parameter Monitoring System 500 Technical Compendium CDI Blood Parameter Monitoring System 500 CDI Blood Parameter Monitoring System 500 System Overview The CDI System 500
More informationOn the way to the smart plant Safety technology in the digital age
On the way to the smart plant Safety technology in the digital age ON THE WAY TO THE SMART PLANT Digital becomes smart Connecting safety technology devices with industrial systems enhances the safety of
More informationRESAMPLING METHODS FOR SIGNALS RECORDED AT VARIABLE SAMPLE-TIME INTERVALS DURING GENERAL ANESTHESIA
RESAMPLING METHODS FOR SIGNALS RECORDED AT VARIABLE SAMPLE-TIME INTERVALS DURING GENERAL ANESTHESIA Diego F. Sendoya-Losada, Faiber Robayo Betancourt and José Salgado Patrón Department of Electronic Engineering,
More informationCLINICAL MASS SPECTROMETRY DATA MANAGEMENT SOFTWARE FROM SAMPLE COLLECTION TO RESULT MSMS WORKSTATION SOFTWARE
CLINICAL MASS SPECTROMETRY DATA MANAGEMENT SOFTWARE FROM SAMPLE COLLECTION TO RESULT PROCESS MORE SAMPLES IN LESS TIME WITH MORE ACCURATE RESULTS 10 REASONS TO CHOOSE MSMS Workstation software (IVD) provides
More informationPERIOPERATIVE CLOSED-LOOP CONTROL OF ANALGESIA IN HUMANS
1 of 4 Proceedings 23rd Annual Conference IEEE/EMBS Oct.25-28, 1, Istanbul, TURKEY PERIOPERATIVE CLOSED-LOOP CONTROL OF ANALGESIA IN HUMANS Christoph Schaniel 1, Andrea Gentilini 1, Manfred Morari 1, Christian
More informationSystem design for Simultaneous Data Acquisition from Patient Monitor and Syringe Pumps in Intensive Care Unit
System design for Simultaneous Data Acquisition from Patient Monitor and Syringe Pumps in Intensive Care Unit N. Sprunk M. Kaur TUM Graduate School of Information Science in Health (GSISH) TUM Technische
More informationHigh performance comes easily
High performance comes easily Philips MX 16-slice CT Easy from any The CT solution Your days may not be getting any easier, but now your CT solution is. The remarkably easy-to-use Philips MX 16-slice CT
More informationStreamlining Data Management Workflow
Streamlining Data Management Workflow Application Note Introduction The clinical data captured by AEDs and advanced life support monitor/defibrillators during resuscitation and transport is extremely valuable.
More informationMMS-TL Series Materials Management System Tank Level. ISO-9001:2000 certified. More than just another level measurement company.
ISO-9001:2000 certified MMS-TL Series Materials Management System Tank Level More than just another level measurement company. PRODUCT INTRODUCTION The MMS-TL Series is a materials management software
More informationControl Of Anaesthesia Concentration Using Model Based Controller
Control Of Anaesthesia Concentration Using Model Based Controller Ninu Jagannivas 1, Hepsiba.D 2 1 PG Scholar, 2 Assistant Professor Dept. Electronics and Instrumentation, Karunya University Coimbatore,
More informationDeltaV Engineering Seat Software Suite
DeltaV Distributed Control System Product Data Sheet December 2017 DeltaV Engineering Seat Software Suite Powerful, graphical engineering capabilities Engineering functionality on demand Temporary use
More informationMetaVision Perfusion. Advanced patient data management system that supports perfusionist workflow
MetaVision Perfusion Advanced patient data management system that supports perfusionist workflow This document is intended to provide information to an international audience outside of the US. Safe.
More informationAuthor(s) Araki, Mituhiko; Fukuda, Kazuhiko. works must be obtained from the IEE
Title A model-predictive hypnosis intravenous anesthesia control Author(s) Sawaguchi, Yoshihito; Furutani, Eik Araki, Mituhiko; Fukuda, Kazuhiko Citation IEEE TRANSACTIONS ON BIOMEDICAL ENG (2008), 55(3):
More informationCapital Market Day June 12, 2012
Capital Market Day 2012 June 12, 2012 Product Segments IV Drugs John Ducker Member of the Management Board President Region North America Capital Market Day Fresenius Kabi, June 12, 2012 Agenda 1 2 3 4
More informationEnterprise Risk Management
Enterprise Risk Management Managing Risk with Precision Market Risk Credit Risk Operational Risk Manage Risk across your Bank Market Risk Management Credit Risk Management Operational Risk Management BASEL
More informationCedex Bio Bioprocess Analyzer. Be Confident. Be Assured.
Cedex Bio Bioprocess Analyzer Be Confident. Be Assured. Next Generation Technology for Bioprocess Analytics Metabolite Screening Substrate Analysis Fermentation Analysis At-Line Monitoring Analyze your
More informationClosed-Loop Anesthesia in Children using a PID Controller: A Pilot Study
Closed-Loop Anesthesia in Children using a PID Controller: A Pilot Study Soltesz, Kristian; van Heusden, Klaske; Dumont, Guy A.; Hägglund, Tore; Petersen, Christian; West, Nicholas; Ansermino, J. Mark
More informationThe development of Diprifusor : a TCI system for propofol
The development of Diprifusor : a TCI system for propofol J. B. Glen Medical Research and Communications Group, Zeneca Pharmaceuticals, Alderley Park, Macclesfield, Cheshire SK10 4TG, UK Summary The Diprifusor
More informationTO RESULT SOFTWARE DATA MANAGEMENT MASS SPECTROMETRY FROM SAMPLE COLLECTION MSMS WORKSTATION SOFTWARE
C L I N I C A L MASS SPECTROMETRY DATA MANAGEMENT SOFTWARE FROM SAMPLE COLLECTION TO RESULT MSMS workstation software may not be licenced in accordance with the laws in all countries, such as the United
More informationBODYGUARD COLOURVISION 575 PCA INFUSION PUMP
ColourVision BODYGUARD COLOURVISION 575 PCA INFUSION PUMP The BodyGuard ColourVision 575 PCA Infusion Pump is a dedicated, colourcoded pain management system, for Patient Controlled Analgesia (PCA) infusions
More informationCareCenter MD The first PC-based, wireless, diagnostic workstation
CareCenter MD The first PC-based, wireless, diagnostic workstation The comprehensive and cutting-edge ECG and Stress solution for today s physicians. Cardiac Science, the company behind the trusted Burdick
More informationPopulation based pharmacokinetic analysis: why do we need it; what is it; and what has it told us about anaesthetics?
British Journal of Anaesthesia 1998; 80: 488 501 REVIEW ARTICLE Population based pharmacokinetic analysis: why do we need it; what is it; and what has it told us about anaesthetics? P. M. C. WRIGHT To
More informationPageScope Enterprise Suite End to End Printing Administration. Solutions PageScope Enterprise Suite
Enterprise Suite End to End Printing Administration Solutions Enterprise Suite Enterprise Suite Central management, streamlined administration, absolute efficiency Time is of the essence in today s business
More informationRIS-BILLING FLEXIBLE BILLING MODULE FOR
RIS-BILLING FLEXIBLE BILLING MODULE FOR iq-ris NEVER LOSE A CENT VERSION 3.0 iq-ris BILLING EFFICIENT BILLING IN RADIOLOGY IMAGE Information Systems Ltd. has developed a dynamic billing system that can
More informationCOMPUTER CONTROLLED INFUSION OF PROPOFOL
Br. J. Anaesth. (1989), 62, 46-53 COMPUTER CONTROLLED INFUSION OF PROPOFOL R. M. TACKLEY, G. T. R. LEWIS, C. PRYS-ROBERTS, R. W. BOADEN, J. DIXON AND J. T. HARVEY When anaesthesia is to be maintained by
More informationPharmacometric Models in Anesthesia and Analgesia
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Pharmacy 173 Pharmacometric Models in Anesthesia and Analgesia MARCUS BJÖRNSSON ACTA UNIVERSITATIS UPSALIENSIS UPPSALA 2013
More informationMarketsandMarkets. Publisher Sample
MarketsandMarkets http://www.marketresearch.com/marketsandmarkets-v3719/ Publisher Sample Phone: 800.298.5699 (US) or +1.240.747.3093 or +1.240.747.3093 (Int'l) Hours: Monday - Thursday: 5:30am - 6:30pm
More informationPDF of Trial CTRI Website URL -
Clinical Trial Details (PDF Generation Date :- Tue, 09 Oct 2018 14:20:25 GMT) CTRI Number Last Modified On 26/09/2012 Post Graduate Thesis Type of Trial Type of Study Study Design Public Title of Study
More informationDepartment : Trauma O.T. 5 th Floor ( Surgery ) Dated :- 07/01/15 S. No. Andromeda Vacume XP. Vishal Distributor ,
Department : Trauma O.T. 5 th Floor ( Surgery ) S. No. Equipments Name Manufacturer Supplier Last Supervising 1. Bench Top Autoclave S.N.- 00/ R081593 Andromeda Vacume XP Vishal Distributor 9811580946,
More informationEMPOWERING INTELLIGENT FINANCE
EMPOWERING INTELLIGENT FINANCE Empower your working capital solutions with HPD LendScape Adaptable and scalable, HPD LendScape offers funders an end-to-end solution on a single platform. Our expert software
More informationNetwork Management Open Management System for Passport (OMS-P) Release 4.0
Product Brief Network Management Open Management System for Passport (OMS-P) Release 4.0 Features and Benefits Web-Based Access to Management Data provided by HP OpenView NNM 6.01 Updates for Passport
More informationImprove Visibility and Control of Your Siemens Point-of-Care Testing
www.siemens.com/diagnostics Improve Visibility and Control of Your Siemens Point-of-Care Testing RAPIDComm Data Management System Answers for life. Centralize Oversight and Control of Your Point-of-Care
More informationMODELLING AND CLOSED-LOOP CONTROL OF SKELETAL MUSCLE RELAXATION DURING GENERAL ANAESTHESIA USING MIVACURIUM
MODELLING AND CLOSED-LOOP CONTROL OF SKELETAL MUSCLE RELAXATION DURING GENERAL ANAESTHESIA USING MIVACURIUM K.S. Stadler, D. Leibundgut, P.M. Schumacher, T. Bouillon, A.H. Glattfelder, A.M. Zbinden Automatic
More informationGE Healthcare. CoreScan application: Dedicated to quantifying visceral fat.
GE Healthcare CoreScan application: Dedicated to quantifying visceral fat. The need for knowledge. Today, there s an urgent need to know more about the links between visceral adipose tissue (VAT), obesity,
More informationTarget-Controlled Drug Delivery
CLINICAL CONCEPTS AND COMMENTARY Richard B. Weiskopf, M.D., Editor Anesthesiology 2003; 99:1214 9 Target-Controlled Drug Delivery 2003 American Society of Anesthesiologists, Inc. Lippincott Williams &
More informationGE Healthcare. OEC Brivo Plus. Simply speed up!
GE Healthcare OEC Brivo Plus Simply speed up! Introducing the OEC Brivo Plus For more than four decades, OEC has been committed to delivering highquality, innovative advances in mobile surgical imaging
More informationPharmacokinetic pharmacodynamic modelling in anaesthesia
ritish Journal of Clinical Pharmacology DOI:10.1111/bcp.12286 Pharmacokinetic pharmacodynamic modelling in anaesthesia Pedro L. Gambús 1,2,3 & Iñaki F. Trocóniz 4 1 Systems Pharmacology Effect Control
More informationFuzzy control of neuromuscular block during general anesthesia system design, development and implementation
International Journal of General Systems ISSN: 0308-1079 (Print) 1563-5104 (Online) Journal homepage: http://www.tandfonline.com/loi/ggen20 Fuzzy control of neuromuscular block during general anesthesia
More informationVolumetric infusion pumps. Barcode Assisted Infusion: Innovative infusion therapy solutions
Volumetric infusion pumps Barcode Assisted Infusion: Innovative infusion therapy solutions Volumetric infusion pumps Introducing the next generation of innovative Barcode Assisted Infusion (BAI) In today
More informationQuantification of the variability in response to propofol administration in children
Quantification of the variability in response to propofol administration in children van Heusden, Klaske; Ansermino, J. Mark; Soltesz, Kristian; Khosravi, Sara; West, Nicholas; Dumont, Guy A. Published
More informationAccelerate your wor k fl ow
Accelerate your wor k fl ow Philips Holter Monitoring System DigiTrak XT Release 2.9 Designed to meet your Philips Holter Monitoring System is designed to simplify life for you and your patients. It provides
More informationEnterprise APM version 4.2 FAQ
Meridium Enterprise Asset Performance Management (APM) version 4.2 is the next generation APM solution that helps your company simply and easily connect disparate systems and use that data to create and
More informationF O C U S O N P A T I E N T S
FOCUS ON PATIENTS FOCUS ON PATIENTS Data Management in Emergency Medicine With the mission-upload function of the corpuls3 all medical and technical mission data is transferred to the corpuls.web ANALYSE
More informationPrepared for the unpredictable at any price?
Prepared for the unpredictable at any price? Safety First! that is a principle that any decision maker would confirm before a shutdown. But the reality is often different. A study reveals the tension between
More informationMOBILE Modelling, Optimization and mp-mpc of Biomedical Systems. Stratos Pistikopoulos
MOBILE Modelling, Optimization and mp-mpc of Biomedical Systems Stratos Pistikopoulos Outline The MOBILE proect a brief overview Focus on Leukaemia Anaesthesia Overview - ERC Advanced Grant MOBILE proect
More informationACTAtek Timesheet User Manual
ACTAtek Timesheet User Manual Version 1.1 30 October 2008 ACTAtek UK Limited Revision History Revision Date Description Author 1.0 7 July 2008 Initial Release Nicola 1.1 16 October 2008 Sage Integration
More informationWORKLIST. Optimizing your workflow
WORKLIST dicom Worklist server Optimizing your workflow VERSiON 2.0 iq-worklist CONSISTENT DATA throughout RIS and PACS iq-worklist is a powerful DICOM worklist server and a must-have in every imaging
More informationThe Intelligent Simulation in Inhalational Anaesthesia
The Intelligent Simulation in Inhalational Anaesthesia JIANN-SHING SHIEH 1, WEN-LONG SHI 1, SHOU-ZEN FAN 2 1 Department of Mechanical Engineering, 2 Department of Anesthesiology 1 Yuan Ze University, 2
More informationIntegrated IP Console (IIC)
Integrated IP Console (IIC) NEC Corporation (Thailand) Ltd th.nec.com The ultimate professional console for receptionists, attendants and switchboard operators. Overview Business benefits Switchboard operators,
More informationDisposition of Remifentanil in Obesity
A New Pharmacokinetic Model Incorporating the Influence of Body Mass Tae Kyun Kim, M.D., Shinju Obara, M.D., Talmage D. Egan, M.D., and the Remifentanil Pharmacokinetics in Obesity Investigators* ABSTRACT
More informationautolog Autotransfusion System
autolog Autotransfusion System Medtronic: A Pioneer in Blood Component Technologies Medtronic has been a key participant in the area of blood component therapies for more than a decade. We are committed
More informationPUTTING PATIENTS FIRST: INNOVATING DRUG CONTAINMENT AND DELIVERY
PUTTING PATIENTS FIRST: INNOVATING DRUG CONTAINMENT AND DELIVERY Innovations in self-administered drug delivery systems are supporting care for a variety of medical conditions transitioning out of hospitals
More informationPHOCUS Rx TM. Remote IV Compounding Validation. i.v.tools TM Making Compounding Safer
PHOCUS Rx TM Remote IV Compounding Validation i.v.tools TM Making Compounding Safer PHOCUS Rx TM Low resolution PDF file. For high resolution files, please contact Communication & Image Dept. Phocus Rx
More information