If there are illegible images in this package, legible images may be found online via under My UL Reports/CDA.

Size: px
Start display at page:

Download "If there are illegible images in this package, legible images may be found online via under My UL Reports/CDA."

Transcription

1 MR. KYLE YU, SAFETY ENGINEER SINPRO ELECTRONICS CO LTD 5 YUANXI ST P E P Z PINGTUNG Date: 2011/01/12 PINGTUNG HSIEN Subscriber: TAIWAN PartySite: File No: E Project No: 10SC04925 PD No: 11O01149 Type: R PO Number: Subject: Procedure And/Or Report Material The following material resulting from the investigation under the above numbers is enclosed. Issue Date Vol Sec Pages Revised Date X1 Index Page(s) 2011/01/11 X1 A41 Add New Proc/Report Sect If there are illegible images in this package, legible images may be found online via MyHome@UL under My UL Reports/CDA. Inspections at your plant will be conducted under the supervision of TERENCE HUANG, FIELD SUPERVISOR, UL INSPECTION CENTER TAICHUNG, UL INTERNATIONAL SERVICES LTD, 1ST FL, 260 DA-YEH RD, PEITOU, TAIPEI CITY,., Taiwan, 112., PHONE: , FAX: , TERENCE.HUANG@TW.UL.COM Please file revised pages and illustrations in place of material of like identity. New material should be filed in its proper numerical order. NOTE: Follow-Up Service Procedure revisions DO NOT include Cover Pages, Test Records and Conclusion Pages. Report revisions DO NOT include Authorization Pages, Indices, Section General Pages and Appendixes. Please review this material and report any inaccuracies to This material is provided on behalf of Underwriters Laboratories Inc.(UL) or any authorized licensee of UL. SCL File UL INSPECTION CENTER 817

2 File Volume Page Date: E Index X Index Product Type Model/Type Reference AC SPU30-XYY and IPU30-XYY, where X may be , and Y may be 0-9, A, B, or blank SPU63-X, IPU63-X (where X = 105, 106, 107, 108, 109, 110 or 111), AP0A0003AA, SPU PS01, AW-PS550(*1)(*2), where (*1) = A-Z or 0-9 ; (*2) = A-Z or 0-9 or Blank. SPU20A-X, IPU20A-X (X = 102, 105, 106, 108, 109, (Desktop) 111) SPU20B-X, IPU20B-X (X = 102, 105, 106, 108, 109, (Desktop) (Desktop) 111) SPU40-102, SPU40-104, SPU40-105, SPU40-107, SPU40-108, SPU40-111, SPU40-103, SPU40-106, SPU40-109, SPU40-110, IPU40-102, IPU40-104, IPU40-105, IPU40-107, IPU40-108, IPU40-111, IPU40-103, IPU40-106, IPU40-109, IPU AC Power PSE10-10 SPU68-105, IPU68-105, SPU68-108, IPU Power SPU16x-y, IPU16x-y and EPU16x-y, where x can be A, C or E, y can be 101, 102, 103, 104, 105, 106, Power (Desktop) 107, 108, 109, 110 or 111. SPU16x-y and IPU16x-y, (where x can be B or D, y can be 101, 102, 103, 104, 105, 106, 107, 108, 109, 110 or 111); JT-H300AD-P1 SPU25A-X, SPU25C-X, IPU25A-X, IPU25C-X (X = 102, 103, 104, 105, 106, 107, 108,109, 110, 111), VSK0727, VSK0728, VSK0729, VSK0730 SPU25B-X, IPU25B-X (X= 102, 103, 104, 105, 106, 107, 108,109, 110, 111) MPU ) SPU46-102, SPU46-103, SPU46-104, SPU46-105, SPU46-106, SPU46-107, SPU46-108, SPU46-109, SPU46-110, SPU Report Reference # E A1-UL E A2-UL E A3-UL E A4-UL E A5-UL E A6-UL E A7-UL E A8-UL E A9-UL E A11-UL E A12-UL E A15-UL E A17-UL Status Direct Plug-In 2) IPU46-102, IPU46-103, IPU46-104, IPU46-105, IPU46-106, IPU46-107, IPU46-108, IPU46-109, IPU46-110, IPU MPU130-X, where X=105, 108; E A18-UL SPU131-Y, where Y=105, 106, 107, 108, 109, 110, 111, 112 SPU31-1XX and IPU31-1XX (X can be 0-9, A-Z, a-z E A19-UL or blank.) SPU10-XY, IPU10-XY (''X'' = ; ''Y'' can be E A28-UL blank or C, ''C'' means "constant current").(see Enclosure Miscellaneous 7-01 for details) HPU100-X, SPU100-X and IPU100-X (where X can E A29-UL be 105, 106, 107, 108, 109, 110 or 111) SPU E A31-UL

3 File Volume Page Date: E Index X Switch Power EPU10-X, APU10-X (X can be 102, 103, 104, 105, 106, 107, 108, 109, 110 or 111) EPU40A-X (X can be 102, 103, 104, 105, 106, 107, 108, 109, 110 or 111) EPU15-X, APU15-X, SPU15-X, IPU15-X (X can be 102, 103, 104, 105, 106, 107, 108, 109, 110 or 111) SPU EPU26-X, APU26-X, SPU26-X, IPU26-X (X can be 102, 103, 104, 105, 106, 107, 108, 109, 110 or 111) EPU20X-Y, APU20X-Y, SPU21X-Y, IPU21X-Y (X can be A or C; Y can be 102, 103, 104, 105, 106, 107, 108, 109, 110 or 111) EPU20X-Y, APU20X-Y, SPU21X-Y, IPU21X-Y (X can be B; Y can be 102, 103, 104, 105, 106, 107, 108, 109, 110 or 111) EPU60A-X, APU60A-X, SPU61A-X, IPU61A-X (X can be 105, 106, 107, 108, 109, 110, 111) E A34-UL E A35-UL E A36-UL E A37-UL E A38-UL E A39-UL E A40-UL E A41-UL

4 Issue Date: Page 1 of 10 Report Reference # E A41-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL , 2nd Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No , 2nd Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) Listing QQGQ, QQGQ7 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) Product: Switch Power Model: EPU60A-X, APU60A-X, SPU61A-X, IPU61A-X (X can be 105, 106, 107, 108, 109, 110, 111) Rating: I/P: Vac, 47-63Hz, 1.45A O/P: (1)12-13Vdc, A, 60W for models EPU60A-105, APU60A-105 SPU61A-105, IPU61A-105. (2)13-16Vdc, A, 60W for models EPU60A-106, APU60A-106 SPU61A-106, IPU61A-106. (3)16-21Vdc, A, 60W for models EPU60A-107, APU60A-107 SPU61A-107, IPU61A-107. (4)21-27Vdc, A, 60W for models EPU60A-108, APU60A-108 SPU61A-108, IPU61A-108. (5)27-33Vdc, A, 60W for models EPU60A-109, APU60A-109 SPU61A-109, IPU61A-109. (6)33-40Vdc, A, 60W for models EPU60A-110, APU60A-110 SPU61A-110, IPU61A-110. (7)40-48Vdc, A, 60W for models EPU60A-111, APU60A-111 SPU61A-111, IPU61A-111. Applicant Name and Address: SINPRO ELECTRONICS CO LTD 5 YUANXI ST P E P Z PINGTUNG PINGTUNG HSIEN 900 TAIWAN This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. Copyright 2011

5 Issue Date: Page 2 of 10 Report Reference # E A41-UL Prepared by: Reviewed by: Eric Liu Underwriters Laboratories Inc. Kyle Lin Underwriters Laboratories Inc. Copyright 2011

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-03-30 Page 1 of 12 Report Reference # E186249-A59-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment

More information

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Daniel Livingston

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Daniel Livingston MD200001 AGENCY DOCUMENTS, ET2401LM Series REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO-13-0706 Daniel Livingston Daniel Livingston September 12, 2013 DOC #: MD200001

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2015-09-29 Page 1 of 14 Report Reference # E182560-V4-S20 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2015-09-28 Page 1 of 10 Report Reference # E182560-V4-19 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2015-12-22 Page 1 of 13 Report Reference # E182560-V4-S35 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-02-09 Page 1 of 22 Report Reference # E254758-A32-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: ANSI/AAMI ES60601-1 (2005 + C1:09 + A2:10)(Medical

More information

QQGQ2.E Power Supplies, Information Technology Equipme... Business Equipment - Component

QQGQ2.E Power Supplies, Information Technology Equipme... Business Equipment - Component QQGQ2.E317867 - Power Supplies, Information Technology Equipme... of 105 11/11/2013 1:47 PM QQGQ2.E317867 Power Supplies, Information Technology Equipment Including Electrical Business Equipment - Component

More information

Elo Stacks on POS Value

Elo Stacks on POS Value Elo Stacks on POS Value Reinventing point of sale to embrace new forms of payment, engage shoppers, reward loyalty, and ensure fast service. Elo POS Products ipad PayPoint X-Series E-Series I-Series POS

More information

MANUFACTURER'S RESPONSIBILITIES AND REQUIREMENTS FOR FACTORY TESTS

MANUFACTURER'S RESPONSIBILITIES AND REQUIREMENTS FOR FACTORY TESTS MANUFACTURER'S RESPONSIBILITIES AND REQUIREMENTS FOR FACTORY TESTS 1.0 MANUFACTURER'S RESPONSIBILITIES: The manufacturer's responsibilities include, but are not limited to: 1.1 Control of UL Mark - Restrict

More information

An Urgent Bulletin from CSA International

An Urgent Bulletin from CSA International Ref No: I10-071 Verification Service Announcement No. 47 (Supersedes Verification Service Announcements Nos. 2 and 2A) Date: June 24, 2010 An Urgent Bulletin from CSA International New Verification Service

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70128861 Master Contract: 229177 (LR 103294) Project: 70128861 Date Issued: 2017-04-04 Issued to: Murata Power Solutions 4118 14th Ave Markham, Ontario L3R 0J3 CANADA

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL CUSTOMER. MODEL NO. BPHE010C701-50 PART NO. LKBPHE010C701-P1-01 MODEL NAME. 10W 15V 700mA LED Driver DATE. 2010/01/15 APPROVED SIGNATURES (Taiwan Headquarter) 5F,NO.127, Lane

More information

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S Type List Terminal style Quick terminal Contact form Designation Features A general purpose Power Relay. Contact rating up to 12A 250VAC (). Epoxy sealed type and flux free. Quick connect terminal or PCB

More information

Electromagnetic Compatibility Test Report. For. Calorique Ltd.

Electromagnetic Compatibility Test Report. For. Calorique Ltd. Project: File: 06CA27374 MC15305 Date: 6/27/2006 Model: FLR17P10W120V & US66P300M220V10 Electromagnetic Compatibility Test Report For Calorique Ltd. Copyright 2005 Underwriters Laboratories Inc. Underwriters

More information

LEVEL 1 Application for Interconnection and Net Metering

LEVEL 1 Application for Interconnection and Net Metering LEVEL 1 Application for Interconnection and Net Metering Use this application form only for a generating facility that is inverter based and certified by a nationally recognized testing laboratory to meet

More information

LEVEL 2 Application For Interconnection And Net Metering

LEVEL 2 Application For Interconnection And Net Metering LEVEL 2 Application For Interconnection And Net Metering Use this Application form when generating facility is not inverter-based or is not certified by a nationally recognized testing laboratory to meet

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL CUSTOMER 菱洋 MODEL NO. PART NO. MODEL NAME DATE BPCE030C701 LKBPCE030C701-P1-01 30W 42V LED DRIVER 2010/1/20 APPROVED SIGNATURES LinkCom Manufacturing Co., Ltd (Taiwan Headquarter)

More information

File E Project June 27, 2014 REPORT. Cabinets and Cutout Boxes. BOCCHIOTTI SPA Milano, MI, Italy

File E Project June 27, 2014 REPORT. Cabinets and Cutout Boxes. BOCCHIOTTI SPA Milano, MI, Italy Copyright 2014 UL LLC File E466141 Project 4786190420 June 27, 2014 REPORT On Cabinets and Cutout Boxes BOCCHIOTTI SPA Milano, MI, Italy UL LLC authorizes the above named company to reproduce this Report

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2004-09-15 Page 4 of 55 Report Reference # E116994-A16-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL2601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70072210 (065182_0_000) Issued to: EGS Electrical Group LLC 9377 W Higgins Rd Rosemont, Illinois 60018 USA Attention: Mickey Scherer The products listed below are

More information

Effective Date: October Rev. 11/6/2017- Void After: October Product: Roof Drains File No. 4835

Effective Date: October Rev. 11/6/2017- Void After: October Product: Roof Drains File No. 4835 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Australian Standard. Qualification of welders for fusion welding of steels AS AS

Australian Standard. Qualification of welders for fusion welding of steels AS AS AS 2980 2004 AS 2980 2004 Australian Standard Qualification of welders for fusion welding of steels This Australian Standard was prepared by Committee WD-003, Welding of Structures. It was approved on

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2701662 Master Contract: 201067 Issued to: Chalmit Lighting A Division of Hubbell Lighting Ltd. 388 Hillington Rd Glasgow, G52 4BL United Kingdom Attention: Mr. George

More information

ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS (EEHA) MAINTENANCE STANDARD

ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS (EEHA) MAINTENANCE STANDARD Planning and Capability Group Mechanical and Electrical Services ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS (EEHA) Document No.: VERSION 1 REVISION 3 AUGUST 2014 FOREWORD Electrical Equipment in Hazardous

More information

SECTION to 5000 AMPERE PLUG-IN AND FEEDER BUSWAYS - SPECTRA. A. Low-Voltage Plug-in Busway to 5000 ampere, 600 VAC

SECTION to 5000 AMPERE PLUG-IN AND FEEDER BUSWAYS - SPECTRA. A. Low-Voltage Plug-in Busway to 5000 ampere, 600 VAC PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Low-Voltage Plug-in Busway - 225 to 5000 ampere, 600 VAC 1.02 RELATED

More information

TEST REPORT Report No.: HC90234/2017 Page: 1 of 7 Date: October 30, 2017

TEST REPORT Report No.: HC90234/2017 Page: 1 of 7 Date: October 30, 2017 Page: 1 of 7 Date: October 30, 2017 GLACIALTECH INC. 6FL., NO. 346, SEC.2, JUNG SHAN RD., JUNG HE DIST., NEW TAIPEI CITY, TAIWAN The following merchandise was submitted and identified by the vendor as:

More information

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 4CS12 4CS-1/2 4X1-7/8D Handybox Appleton/Oz Gedney Catalog Number 4CS12 Manufacturer Appleton/Oz

More information

Test Report for Enclosure Protection Testing of Enclosed DC Isolator to AS60529:2004

Test Report for Enclosure Protection Testing of Enclosed DC Isolator to AS60529:2004 Page 1 of 7 Test Report for Enclosure Protection Testing of Enclosed DC Isolator to AS60529:2004 Client: IPD Group LTD Address: 25 Princes Road East, Regents Park, NSW 2143 Report Number: Date of Testing:

More information

Copyright 2018 Underwriters Laboratories LLC. UL International (UK) Ltd. 220, Cygnet Court, Centre Park, Warrington. WA1 1PP

Copyright 2018 Underwriters Laboratories LLC. UL International (UK) Ltd. 220, Cygnet Court, Centre Park, Warrington. WA1 1PP Project number: 4788656094-A 10 th October 2018 ASSESSMENT REPORT On IPASSIVE FR ASF sealant Title The Performance of IPASSIVE FR ASF sealant in Accordance with AS 4072.1: 2005 & AS 1530.4 2005/14 ipassive

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2016-08-25 Page 1 of 8 Report Reference # E135494-A109-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

Product: Plumbing Fixtures (Stainless Steel) File No. 5914

Product: Plumbing Fixtures (Stainless Steel) File No. 5914 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

EXPLOSION-PROOF MOTORS

EXPLOSION-PROOF MOTORS Frames 143T~447TZ Horizontal Totally-Enclosed Fan-Cooled Explosion Proof Squirrel Cage Induction Motors Hazardous Locations, Div. I Class I: Group D Class II: Groups E, F & G CSA EPACT energy verification

More information

MEASUREMENT REPORT of WIRELESS LAN PCI CARD

MEASUREMENT REPORT of WIRELESS LAN PCI CARD Test Report ----------------------------------------------------------------------------- 1/36 MEASUREMENT REPORT of WIRELESS LAN PCI CARD Applicant : ASUSTeK COMPUTER INC. Model No. : WL-230 EUT : ASUS

More information

Electricity at Work Regulations, Amendment 1 to BS 7671 and the in-service inspection and testing of electrical equipment

Electricity at Work Regulations, Amendment 1 to BS 7671 and the in-service inspection and testing of electrical equipment Electricity at Work Regulations, Amendment 1 to BS 7671 and the in-service inspection and testing of electrical equipment Chris Johnston Tutor Chief Examiner City & Guilds Slide 1 Electricity at Work Regulations

More information

AS/NZS 3010:2005 AS/NZS

AS/NZS 3010:2005 AS/NZS AS/NZS 3010:2017 Australian/New Zealand Standard Electrical installations Generating sets Superseding AS/NZS 3010:2005 AS/NZS 3010:2017 AS/NZS 3010:2017 This joint Australian/New Zealand standard was prepared

More information

8461C 4SQ, 1"RSD Rndopnw/Ers CVR

8461C 4SQ, 1RSD Rndopnw/Ers CVR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4SQ, 1"RSD Rndopnw/Ers CVR Appleton/Oz Gedney Catalog Number Manufacturer Appleton/Oz Gedney Description Steel Square

More information

NRC INSPECTION MANUAL

NRC INSPECTION MANUAL NRC INSPECTION MANUAL NMSS/RII INSPECTION PROCEDURE MECHANICAL COMPONENTS PROGRAM APPLICABILITY: 2630-01 INSPECTION OBJECTIVES 01.01 To determine whether the technical requirements detailed or referenced

More information

Copyright 2012 Aeronautical Repair Station Association

Copyright 2012 Aeronautical Repair Station Association THE AERONAUTICAL REPAIR STATION ASSOCIATION S MODEL CANADIAN SUPPLEMENT TO THE MODEL REPAIR STATION AND QUALITY MANUAL Copyright 2012 Aeronautical Repair Station Association 703 739 9543 www.arsa.org 121

More information

AS/NZS :2012. Information technology equipment Energy performance of computers AS/NZS :2012

AS/NZS :2012. Information technology equipment Energy performance of computers AS/NZS :2012 AS/NZS 5813.1:2012 Australian/New Zealand Standard Information technology equipment Energy performance of computers Part 1: Methods of measurement of energy performance AS/NZS 5813.1:2012 AS/NZS 5813.1:2012

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2557737 (LR104031) Master Contract: 182407 Issued to: Hummel AG Lise-Meitner-Strasse 2 Denzlingen, 79211 Germany Attention: Klaus Gehri The products listed below

More information

DESIGN REGISTRATION GUIDELINES FOR NUCLEAR PRESSURE RETAINING SYSTEMS AND COMPONENTS

DESIGN REGISTRATION GUIDELINES FOR NUCLEAR PRESSURE RETAINING SYSTEMS AND COMPONENTS Boilers and Pressure Vessels Safety Division Technical Standards & Safety Authority 14th Floor, Centre Tower 3300 Bloor Street West Toronto, Ontario Canada M8X 2X4 www.tssa.org DESIGN REGISTRATION GUIDELINES

More information

Test Data Report for: Hot Water Dispensers, Household Storage Type, Electrical. Tested under ASSE Standard 1023 Issued: 1979

Test Data Report for: Hot Water Dispensers, Household Storage Type, Electrical. Tested under ASSE Standard 1023 Issued: 1979 American Society of Sanitary Engineering Seal (Certification) Program Test Data Report for: Hot Water Dispensers, Household Storage Type, Electrical Tested under ASSE Standard 1023 Issued: 1979 Laboratory

More information

ELEVATING DEVICES CODES REGULATION

ELEVATING DEVICES CODES REGULATION Province of Alberta SAFETY CODES ACT ELEVATING DEVICES CODES REGULATION Alberta Regulation 192/2015 Extract Published by Alberta Queen s Printer Alberta Queen s Printer 7 th Floor, Park Plaza 10611-98

More information

DIGITAL PORTION SCALE PS-5 OWNER S Manual

DIGITAL PORTION SCALE PS-5 OWNER S Manual DIGITAL PORTION SCALE PS-5 OWNER S Manual CARDINAL SCALE MFG. CO. 8528-M013-O1 Rev G PO BOX 151 WEBB CITY, MO 64870 Printed in USA 09/00 PH (417) 673-4631 FAX (417) 673-5001 Web Site - http://www.detectoscale.com

More information

PERMANENT DOCUMENT CIG 024

PERMANENT DOCUMENT CIG 024 CIG 024 The conduct of Factory Inspections PERMANENT DOCUMENT CIG 024 The conduct of Factory Inspections WARNING: THIS DOCUMENT IS ONLY VALID IF USED BY ECS MEMBERS AND THEIR AUTHORISED AGENTS UL does

More information

ExSI05 : SPECIAL SAFETY INSTRUCTION FOR RIO 1XXX INSTRUCTIONS SPECIFIC TO HAZARDOUS AREA INSTALLATIONS The following instructions apply to equipment covered by certificate number ITS12ATEX37696 & IECEx

More information

REPORT INTERTEK ETL SEMKO

REPORT INTERTEK ETL SEMKO REPORT INTERTEK ETL SEMKO 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 ORDER NO.: 30500886 DATE: October 27, 2003 REPORT NO.: 3050088-001 RENDERED TO: Coble Enterprise Co., Ltd. 5F, No. 41, Cheng Ho St.

More information

Standards Australia LICENCE

Standards Australia LICENCE Standards Australia LICENCE Title: Licensee: Date: Conditions of use (Click here for full conditions of Licence) Check if current WEB SEARCH Find similar documents StandardsWatch (Info and Login) Visit

More information

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers)

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers) N1 to N3 Domestic Construction Manual Volume 3: RHS as floor beams (bearers) DuraGal Domestic Construction Manual Volume 1: Roof beams - N1 to C3 (N1 to C3 - Rafters) (N1 to N3 - Roof beams, strutting

More information

(3) 1/2 INCH CONDUIT BOTTOM, (2) 3/4 INCH CONDUIT BOTTOM, (8) 1 INCH CONDUIT SIDES Box

(3) 1/2 INCH CONDUIT BOTTOM, (2) 3/4 INCH CONDUIT BOTTOM, (8) 1 INCH CONDUIT SIDES Box 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4SD1 4S Box 1"Ko 2-1/8DP Appleton/Oz Gedney Catalog Number 4SD1 Manufacturer Appleton/Oz Gedney Description Steel Square

More information

Steel Square Box, Height 4 Inch; Width 4 Inch; Depth 1-1/2 Inch; Capacity 21 Cu Inch; 17 Knockout(S); Knockout Location (5) Bottom, (12) Side

Steel Square Box, Height 4 Inch; Width 4 Inch; Depth 1-1/2 Inch; Capacity 21 Cu Inch; 17 Knockout(S); Knockout Location (5) Bottom, (12) Side 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Knockout Location Knockout Size 4SSPLDR

More information

Agilent 11716A/C Interconnection Kit

Agilent 11716A/C Interconnection Kit Agilent 11716A/C Interconnection Kit Operating Guide Agilent Technologies Notices Agilent Technologies, Inc. 1994, 1996, 1997, 2001, 2002, 2010 No part of this manual may be reproduced in any form or by

More information

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466 BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein

More information

Ref No: Date: March 17, 2000 COMPONENT ACCEPTANCE SERVICE NO. 32

Ref No: Date: March 17, 2000 COMPONENT ACCEPTANCE SERVICE NO. 32 Ref No: 00-005 Date: March 17, 2000 COMPONENT ACCEPTANCE SERVICE NO. 32 To: Subject: Manufacturers of Electrical Equipment and Manufacturers of Supplementary Protectors For Use in Electrical and Electronic

More information

Australian Standard. Equipment for the pasteurization of milk and other liquid dairy products Continuous-flow systems AS AS 3993

Australian Standard. Equipment for the pasteurization of milk and other liquid dairy products Continuous-flow systems AS AS 3993 AS 3993 2003 AS 3993 Australian Standard Equipment for the pasteurization of milk and other liquid dairy products Continuous-flow systems This Australian Standard was prepared by Committee FT-012, Dairy

More information

MUSCO ENGINEERING ASSOCIATES Consulting Engineers

MUSCO ENGINEERING ASSOCIATES Consulting Engineers Consulting Engineers website: www.muscoengineering.com 375 Morgan Lane, Unit 307 West Haven, CT 06516 Telephone #: (203) 932-1901 Fax #: (203) 931-1550 email: admin@muscoengineering.com Electrical Equipment

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2016-08-25 Page 1 of 10 Report Reference # E135494-A109-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

Certificate of Compliance

Certificate of Compliance FF0001 Certificate of Compliance Certificate: 1717515 Issued to: Limatherm SA ul. Tarnowska 1 Limanowa, 34-600 POLAND Attention: Honorata Janik The products listed below are eligible to bear the CSA Mark

More information

ASBESTOS REMOVAL CONTROL PLAN

ASBESTOS REMOVAL CONTROL PLAN APPROVED CODE OF PRACTICE // MANAGEMENT AND REMOVAL OF ASBESTOS ASBESTOS REMOVAL CONTROL PLAN This Appendix is a template of an asbestos removal control plan. It is designed to incorporate the elements

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2715744 (065182_0_000) Issued to: EGS Electrical Group LLC 9377 W Higgins Rd Rosemont, Illinois 60018 USA Attention: Steve Blais The products listed below are eligible

More information

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax:

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax: JB ENGINEERING AND CODE CONSULTING, P.C. 1661 Cardinal Drive Munster, IN 46321 Phone: 219-922-6171 Fax: 219-922-6172 E-Mail: JBEngineer@aol.com JULIUS A. BALLANCO, P.E. President January 15, 2008 Mr. Rick

More information

Company Profile. Quality Compliance and Safety Approvals. P-DUKE Global Sales and Marketing Service

Company Profile.  Quality Compliance and Safety Approvals. P-DUKE Global Sales and Marketing Service Company Profile Company Name : Mate Technology Co.,Ltd. Brand Name : Established : June,1992 Company Address : No.36, 22 nd Rd., Taichung Industrial Park, Taichung City, Taiwan 40850 Tel : 886-4-2359-0668

More information

1.1 All testing apparatus shall be periodically checked and calibrated. Records of such checks/calibration shall be maintained.

1.1 All testing apparatus shall be periodically checked and calibrated. Records of such checks/calibration shall be maintained. SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SINGLE PHASE a.c. INDUCTION MOTORS FOR GENERAL PURPOSE ACCORDING TO IS 996:2009 (Including Amendment No.1) 1. LABORATORY A laboratory shall be maintained

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the MCS 100E HW Multi-Component Analyser Manufactured by: SICK AG Dr Zimmermann Strasse 18 88709 Meersburg Germany Has been assessed by Sira Certification

More information

(IB17-012) Province-wide Variance

(IB17-012) Province-wide Variance VARIANCE No. VA17-004 (IB17-012) Subject Variance to Subsection 6(d) of the Pressure Equipment Safety Regulation regarding the use of 2017 Edition of the ASME Boiler and Pressure Vessel Code, Section VIII,

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 4509.2:2010 Australian/New Zealand Standard Stand-alone power systems Part 2: System design This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee EL-042, Renewable

More information

An Urgent Bulletin from CSA International

An Urgent Bulletin from CSA International Ref No: I10-125 Wiring Harnesses No. 2 (Supersedes INFORMS Wiring Harnesses No. 1) Date: October 29, 2010 An Urgent Bulletin from CSA International Existing Certification not affected Apply any time to

More information

THE KENYA POWER AND LIGHTING CO. LTD

THE KENYA POWER AND LIGHTING CO. LTD THE KENYA POWER AND LIGHTING CO. LTD SPECIFICATION for SINGLE PHASE STATIC METERS FOR ACTIVE ENERGY Compiled by NAME DESIGNATION SIGNATURE DATE Ephantus Nyagah Ag. Senior Engineer Checked by Approved by

More information

Repair Station Forms Training

Repair Station Forms Training Repair Station Forms Training Guide for Regulatory Compliance Creation & Maintenance of Repair Station Forms Advisory Circular 145-9 This Advisory Circular (AC) provides information and guidance material

More information

AS/NZS 5131:2016. Australian/New Zealand Standard. Structural steelwork Fabrication and erection AS/NZS 5131:2016

AS/NZS 5131:2016. Australian/New Zealand Standard. Structural steelwork Fabrication and erection AS/NZS 5131:2016 AS/NZS 5131:2016 Australian/New Zealand Standard Structural steelwork Fabrication and erection AS/NZS 5131:2016 AS/NZS 5131:2016 This joint Australian/New Zealand standard was prepared by joint Technical

More information

Town of East Haven Bid Fire Department Standby Generator Fire Department Station 4

Town of East Haven Bid Fire Department Standby Generator Fire Department Station 4 Town of East Haven Bid 19-03 Fire Department Standby Generator Fire Department Station 4 SEALED BIDS MAY BE SUBMITTED TO THE OFFICE OF THE DIRECTOR OF FINANCE, 250 MAIN STREET, EAST HAVEN, CONNECTICUT

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE UL CERTIFICATE CERTIFICATE OF COMPLIANCE Certificate Number 20160606-E472978 Report Reference E472978-20160217 Issue Date 2016-JUNE-06 Issued to: Blue Point Fasteners 14728 Yorba CT Chino, CA 91710 This

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Intertek Testing Services NA, Inc. TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: 102254161MPK-007

More information

Originally Issued: 03/13/2015 Revised: 03/10/2017 Valid Through: 03/31/ Description

Originally Issued: 03/13/2015 Revised: 03/10/2017 Valid Through: 03/31/ Description EVALUATION SUBJECT: TILE FLASHING SYSTEM REPORT HOLDER: EcoFasten Solar 4741 W. Polk Street, Ste. 4 Phoenix, AZ 85043 Phone: 888-766-4273 brian@alpinesnowguards.com CSI DIVISION: 06 WOOD AND PLASTICS CSI

More information

SECTION ASBESTOS CONTAINING MATERIALS REMEDIATION

SECTION ASBESTOS CONTAINING MATERIALS REMEDIATION SECTION 13280 ASBESTOS CONTAINING MATERIALS REMEDIATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Furnishing all labor, materials, equipment, and transportation necessary for properly and safely removing,

More information

WELDING INSPECTION TECHNOLOGY

WELDING INSPECTION TECHNOLOGY WELDING INSPECTION TECHNOLOGY FIFTH EDITION 2008 Published by American Welding Society Education Department Education Services WELDING INSPECTION TECHNOLOGY DISCLAIMER The American Welding Society, Inc.

More information

QPS Evaluation Services Inc.

QPS Evaluation Services Inc. QPS Evaluation Services Inc. Testing, Certification, and Field Evaluation Body Accredited in Canada, the USA and Internationally YOUR FULL SERVICE PARTNER IN GLOBAL CONFORMITY ASSESSMENT TESTING - CERTIFICATION

More information

1) The products are labeled with an on-product label that was placed there by an FSCcertified

1) The products are labeled with an on-product label that was placed there by an FSCcertified Forest Stewardship Council United States Trademark License Application for Product Promotion This application form is for non-chain of Custody (CoC) certified companies seeking to use the FSC trademarks

More information

ICEA STANDARD FOR DISTRIBUTION FRAME-WIRE TECHNICAL REQUIREMENTS. Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568

ICEA STANDARD FOR DISTRIBUTION FRAME-WIRE TECHNICAL REQUIREMENTS. Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568 ICEA STANDARD FOR DISTRIBUTION FRAME-WIRE TECHNICAL REQUIREMENTS Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568 Carrollton, GA 30112, U.S.A. 2011 Approved July 20, 2011 by

More information

Metal Roof Certification & Listing Program. 1. Program Licensee: This Certification Report was used to qualify Florida Product Approval FL

Metal Roof Certification & Listing Program. 1. Program Licensee: This Certification Report was used to qualify Florida Product Approval FL 145 Limekiln Road, Suite 100B Issue Dated: 6/19/2018 New Cumberland, PA 17070 Revision Date: 6/19/2018 www.keystonecerts.com Expiration Date: 6/19/2023 Construction Specifications Institute (CSI) Category:

More information

DAQ Product Certifications and Optional Certificates

DAQ Product Certifications and Optional Certificates Control Instruments Tech Note DAQ Product Certifications and Optional Certificates CIBU TN2016-02A S. Byrom November 2016 1 CE and CSA All standard data acquisition and recorder products bear CE and CSA

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1602514 (LR 39156) Master Contract: 212516 Issued to: Rosemount Analytical Inc. Process Analytic Division Solon Research & Development Ctr 6565-P Davis Industrial

More information

Flat synthetic-webbing slings Part 2: Care and use

Flat synthetic-webbing slings Part 2: Care and use AS 1353.2 1997 Australian Standard Flat synthetic-webbing slings Part 2: Care and use This Australian Standard was prepared by Committee ME/25, Lifting Tackle. It was approved on behalf of the Council

More information

Occupational health and safety management systems Specification

Occupational health and safety management systems Specification OCCUPATIONAL HEALTH AND SAFETY ASSESSMENT SERIES OHSAS 18001: 1999 Occupational health and safety management systems Specification ICS 03.100.01; 13.100 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED

More information

Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqujbmjgu1j3n... Page 1 of 2 8/15/2018 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats

More information

Production Date: UNKNOWN Contact: MR. XINHUA XIONG Phone: #

Production Date: UNKNOWN Contact: MR. XINHUA XIONG Phone: # VP Engineering SHENZHEN SHENGCHENGHUI CIRCUIT SCIENCE TECHNOLOGIES CO LTD BLK A2 Date: 2008/08/11 YANCHUAN NORTH INDUSTRIAL ZONE Subscriber: 100408934 SONGGANG BAN AN PartySite: 1619137 SHENZHEN 518105

More information

V I S H AY I N T E R T E C H N O L O G Y, I N C. L O A D C E L L S

V I S H AY I N T E R T E C H N O L O G Y, I N C. L O A D C E L L S V I S H AY I N T E R T E C H N O L O G Y, I N C. L O A D C E L L S Load Cells Vishay Tedea-Huntleigh p r o d u c t O v e r v i e w w w w. v i s h a y m g. c o m Load Cells Vishay Tedea-Huntleigh Aluminum

More information

CERTIFICATE OF APPROVAL No CF 5174 BUILDING LIFE (FIRE DOORS) LTD

CERTIFICATE OF APPROVAL No CF 5174 BUILDING LIFE (FIRE DOORS) LTD CERTIFICATE OF APPROVAL No CF 5174 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of BUILDING LIFE (FIRE

More information

帝聞企業股份有限公司 DEE VAN ENTERPRISE CO., LTD. YS DSA-0421S Revision: A Date: 2005,12,06 S068 APPROVAL SHEET SWITCHING ADAPTER MODEL NO.

帝聞企業股份有限公司 DEE VAN ENTERPRISE CO., LTD. YS DSA-0421S Revision: A Date: 2005,12,06 S068 APPROVAL SHEET SWITCHING ADAPTER MODEL NO. CUSTOMER: S068 PART NUMBER: T3717ST APPROVAL SHEET OF ORDER NO: YS3-00072 SWITCHING ADAPTER MODEL NO. DSA-0421S-12 2 42 承認書确認后請簽回㆒份 CUSTOMER APPROVED SIGNATURE DEE VAN ENTERPRISE CO., LTD (Head-Quarter)

More information

DEVELOPMENT SERVICES PO Box 1110 Tampa, FL Date: May 12, Interested Parties. John L. Barrios, CBO, Building Official

DEVELOPMENT SERVICES PO Box 1110 Tampa, FL Date: May 12, Interested Parties. John L. Barrios, CBO, Building Official DEVELOPMENT SERVICES PO Box 1110 Tampa, FL 33601-1110 DEVELOPMENT SERVICES DEPARTMENT Date: May 12, 2017 To: From: SUBJECT: Interested Parties John L. Barrios, CBO, Building Official THRESHOLD BUILDINGS

More information

County of Putnam State of New York

County of Putnam State of New York Year Two Annual Report for "Small" Municipal Separate Storm Sewer Systems (MS4s) March 10, 2004 to March 9, 2005 County of Putnam State of New York May 2005 Prepared By: 3 Garrett Place, Carmel, New York

More information

Year One Annual Report for "Small" Municipal Separate Storm Sewer Systems (MS4s)

Year One Annual Report for Small Municipal Separate Storm Sewer Systems (MS4s) Year One Annual Report for "Small" Municipal Separate Storm Sewer Systems (MS4s) March 10, 2003 to March 9, 2004 County of Putnam State of New York May 2004 Prepared By: 3 Garrett Place, Carmel, New York

More information

ORGANIC HANDLING PLAN

ORGANIC HANDLING PLAN ORGANIC HANDLING PLAN Note: Print or type all information legibly. Use blue ink. Applications will be returned if incomplete or illegible. There is an additional charge for resubmitted applications. Copies

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-32306-6 SOUTH AFRICAN NATIONAL STANDARD Prestressed concrete pipes Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12 428 7911 Fax:

More information

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number PART 1 GENERAL 01 02 03 04 SCOPE Furnish and install Manual Transfer Switches (MTS) and

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1731876 (078713_0_000) Issued to: Hawke International A Division of Hubbell Limited Oxford St W Ashton-Under-Lyne, Lancashire OL7 0NA UNITED KINGDOM Attention: Andy

More information

CHEYENNE COUNTY PERSONAL PROTECTIVE EQUIPMENT PLAN

CHEYENNE COUNTY PERSONAL PROTECTIVE EQUIPMENT PLAN CHEYENNE COUNTY PERSONAL PROTECTIVE EQUIPMENT PLAN I. Purpose This Personal Protective Equipment Plan is necessary to provide a safe workplace for our employees, and to comply with Occupational Safety

More information

AS/NZS 10002:2014. Australian/New Zealand Standard. Guidelines for complaint management in organizations AS/NZS 10002:2014

AS/NZS 10002:2014. Australian/New Zealand Standard. Guidelines for complaint management in organizations AS/NZS 10002:2014 AS/NZS 10002:2014 Australian/New Zealand Standard Guidelines for complaint management in organizations AS/NZS 10002:2014 AS/NZS 10002:2014 This joint Australian/New Zealand standard was prepared by Joint

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70025164 Issued to: Vega Grieshaber KG Am Hohenstein 113 Schiltach, Baden-Württemberg 77761 GERMANY Attention: Sebastian Schaller The products listed below are eligible

More information

Fill out all sections or mark with N/A (not applicable)

Fill out all sections or mark with N/A (not applicable) TOWN of PLAINVILLE 142 South St Plainville, MA. 02762 508-695-3010 ext#12 / fax # 508-695-1857 Commercial Building Permit BUILDING PERMIT INSTRUCTIONS and APPLICATION Please be advised that any incomplete

More information