HydraPressed Slabs. Yorkstone Tan. Wherefunctionmeetsstyle

Size: px
Start display at page:

Download "HydraPressed Slabs. Yorkstone Tan. Wherefunctionmeetsstyle"

Transcription

1 HydraPressed Slabs Yorkstone Tan Wherefunctionmeetsstyle

2 Texada This series is named after the rugged and beautiful Gulf Islands of the Pacific Northwest. Texada HydraPressed Slabs have a light shot-blast architectural finish producing subtle colors with a distinctive elegant appearance. Unsealed Sealed Natural Charcoal Desert Sand Tan Green Red Brown HydraPressedslabsarehydraulicallypressedgivingadense,durable,non-slipsurface.

3 Saturna "Saturna" HydraPressed Slabs receive a deep shot-blast architectural finish exposing the natural hues of the aggregates, creating rich color accents. Unsealed Sealed Natural Charcoal Desert Sand Tan Green Red Brown Thisprocessensuresprecisionsizeswithsquare,trueedgesthatfittogetherperfectly.

4 Yorkstone "Yorkstone" HydraPressed Slabs receive the Abbotsford Concrete Products' distinctive Pacific Slate finish for the look of natural stone. "Yorkstone" slabs are perfect for pool surrounds, patios or any application that requires a little something extra. Unsealed Sealed courtesy of Five Star Paving Natural Charcoal Desert Sand Tan Green Withthisadvancedmethodofproducingconcretepaving,themixissubjectedto400tonnes

5 Sandstone "Sandstone" HydraPressed Slabs are created in the same manner as Texada by applying a light shot-blast architectural finish to our Yorkstone. Create unique and beautiful patterns by using a combination of Yorkstone and any of our other HydraPressed Slab Series. The possibilities are yours to imagine. Unsealed Sealed Natural Charcoal Desert Sand Tan Green ofhydraulicpressuregivingstrength,densityanddurabilitycomparabletonaturalstone.

6 Abbotsford Concrete's On-Site Stormwater Source Control System Abbotsford Concrete Products introduces AquaSlab, paving units for use over full, partial, or no exfiltration base designs. AquaSlabs support pedestrian applications only. AquaSlabs provide drainage through openings in the surface created by vertical slots on the sides of the units. These allow water to enter and flow at rates as high as 354 in./hour (9000 mm/m 2 /hr or 9000 litres/m 2 /hr). 457 mm mm mm available in 42, 50 or 60 mm FindmoredetailsaboutAbbotsfordConcrete'sAquaSlabandAquaPaveOn-

7 Benefits Lower Construction Costs In conventional drainage design, infiltration and detention facilities are separate from impervious paved areas. AquaSlab On-Site Stormwater Source Control System combines the pavement area, infiltration and detention facilities into one location, allowing more space on the site for incomegenerating buildings. For some designs there can be savings from decreasing or eliminating drain pipes and appurtenances such as inlets and utility structures. AquaSlabs can give you a superior surface at a lower cost than traditional paving methods. With its flat continuous surface, AquaSlabs accept pavement marking materials such as paint and thermal plastic tapes. Reduction of Runoff With an open surface area of about 2%, the openings can infiltrate as much as 354 in./hr (9000 mm/m 2 /hour or 9000 litres/m 2 /hr). The infiltration rate of the crushed stone used for the bedding and base is similar. For design purposes, a conservative 90% reduction in efficiency is generally assumed for infiltration facility design, due to the build-up of sediment over years of service. When considering a 90% reduction of initial infiltration as a typical design assumption, the AquaSlab On-Site Stormwater Source Control System will still capture, treat, infiltrate, and filter rainstorms over 35.4 in./hour (900 mm/m 2 /hr or 900 litres/m 2 /hr). This includes the commonly recurring storms, which generate the most pollution. Roof Water Roof water can be discharged into the sub-base. With gravity fed drainage it is recommended that the water is introduced into the sub-base by means of a sump with a manhole cover adjacent to the paved area. Any debris can be easily caught and cleared. The water is then dispersed within the system via a permavoid distribution tank or perforated outlet pipe. With siphonic drainage, a special chamber is used to disperse the water within the sub-base. Filtering and Treatment of Pollutants Studies of permeable interlocking concrete pavement and its sister practice, infiltration trenches, have shown substantial reduction of non-point source pollutants in runoff. The open-graded crushed stone base has an approximate storage volume of at least 30%. This storage capacity enables a decrease in peak flows and treatment of pollutants, especially nutrients and total suspended solids prior to drainage of the water from the base through drain pipes. Substantial reductions of metals can occur in full or partial base exfiltration designs where the water enters silt and clay soils. Typical AquaSlab Construction Detail Curb/edge restraint with cut-outs for overflow drainage 50mm 150mm AquaSlab 42, 50 or 60 mm Bedding course 5mm clear crush ACP-SC Inbitex Geotextile Sub base 20-5mm aggregate ACP-SC1000 or 2000 Woven Geotextile on bottom and sides of open graded base Soil subgrade-sloped to drain SiteStormwaterSourceControlSysytemat oratwww.pavingstones.com

8 Specialties Abbotsford Concrete Products prides itself in being able to customize to your unique requirements. Our HydraPressed Slabs are available in the following: Standard Sizes: 24" x 24" x 2" 610mm x 610mm x 50mm 18" x 18" x 1-5/8" 457mm x 457mm x 40mm Cut to Sizes: 24" x 12" x 2" 610mm x 305mm x 50mm 18" x 9" x 1-5/8" 457mm x 229mm x 40mm 12" x 12" x 2" 305mm x 305mm x 50mm 9" x 9" x 1-5/8" 229mm x 229mm x 40mm Custom Inlays For those projects that require something a little out of the ordinary, such as special sizing or custom coloring, please contact your Abbotsford Concrete representative for assistance. HydraPressed Drains ADA* HydraPressed Slab *(American Disabilities Act) Interior Application Specialsizing,customcolors,decorativeshot-blastpatternsareavailabletomakeyourprojectunique.

9 HydraPressed Slab Installation Details: - Mortar Set HydraPressed Paving Slabs Thinset Zero Slump Mortar Bed w/reinforcing Mesh Waterproofing System (by others) Structural Concrete Sand Set HydraPressed Paving Slabs 3/4-1 Sand Setting Bed (Washed Concrete Sand) 6-8 Compacted Aggregate Base (3/4 Minus Roadbase Material )

10 HydraPressed Slab Roof Installation using pedestals with HydraPressed Paving Slabs are used for pedestrian traffic or in areas where light maintenance vehicles (ie. golf carts) operate. HydraPressed Paving Slabs are installed on sand, mortar, or pedestal systems, for patios, plaza decks, roof tops, or any other type of pedestrian walking surface. Overview HydraPressed Paving Slabs Pedestals Extruded Polystyrene Insulation Protection Board and/or Drain Mat Waterproofing Membrane Structural Concrete Pedestal systems are designed for use over pitched surfaces. These systems ensure precise HydraPressed Slab alignment and even spacing to allow for drainage and air circulation which are critical to the health of any deck installed over a waterproof membrane. This type of segmental system allows for ease of access for repairs or annual maintenance to the subsurface without damage to the HydraPressed Slabs. Note: When specifying these types of built-up roof systems, be sure to consult the waterproofing manufacturers design details and specifications. Forplazaorrooftopinstallations,cautionshouldbeexercisedwithrespect

11 various waterproofing systems Modified Bitumen HydraPressed Paving Slabs Pedestals Extruded Polystyrene Insulation (Optional) Protection Board and/or Drain Mat Waterproofing Membrane (ie, peel & stick, BUR, APP or SBS) Primer Structural Concrete Hot Rubber HydraPressed Paving Slabs Pedestals Extruded Polystyrene Insulation (Optional) Protection Board and/or Drain Mat Hot Applied Membrane Reinforcing Fabric Hot Applied Membrane Primer Structural Concrete Single Ply Sheet Membrane HydraPressed Paving Slabs Pedestals Extruded Polystyrene Insulation (Optional) Protection Board and/or Drain Mat Waterproofing Membrane (ie, EPDM, PVC, TPO or CSPE) Structural Concrete totheweightoftheproductaswellasthewindvelocitiesintheareasofuse.

12 HydraPressed Paving Slab Specifications 1.0 Qualifications: The manufacturer is to be prequalified by the specifier, with the manufacturer having a minimum of 5 years experience in precast concrete pavers, and specialty products. 2.0 References: Materials must conform to the following ASTM and CSA Standards: A) ASTM 150, CSA A5 : Specification for Portland Cement B) ASTM C33, CSA A23.1 : Specification for Normal Weight Aggregates C) ASTM C979 : Specification for Pigments D) ASTM C140, CSA A : Specification for Compressive Strength E) CSA A : Specification for Flexural Strength F) ASTM C140, CSA A : Specification for Water Absorption G) CSA A : Specification Freeze/Thaw 3.0 Technical Specifications: Compressive Strength: Average compressive strength shall not be less than 8000 PSI (55 MPA) with no individual unit less than 7300 PSI (50 MPA) when tested not less than 28 days from the date of production in accordance with ASTM C140, or CSA A Flexural Strength: Average flexural (transverse) strength of the concrete paving slabs shall be at least 655 PSI (4.5 MPA) with no individual unit below 582 PSI (4.0 MPA) when tested in accordance with CSA A Water Absorption: Average water absorption shall not be greater than five percent (5%) with no individual unit greater than seven percent (7%), when tested in accordance with ASTM C140. CSA A Scaling Resistance: Specimens shall not have an average loss of mass greater than 300 g/m2 of the total inundated surface area of the individual paving slab after 28 cycles of freezing and thawing, 800 g/m2 after 49 cycles. Specimens with an architectural finish shall not have an average loss of mass greater than 500 g/m2 of the total inundated surface area of the individual paving slab after 28 cycles of freezing and thawing, or 1200 g/m2 after 49 cycles. When tested in accordance with CSA A Dimensions: Dimensions of paving slabs and concave or convex warpage shall not differ from those agreed upon by the manufacturer by more than the following amounts: a) Length and width: -1.0 mm to mm b) Height +_ 3.0 mm c) Concave or convex warpage in one dimension by the following amounts: i) up to 450 mm, 2.0 mm; or ii) over 450 mm, 3.0 mm. Dimensions are based on manufacturer s standard drawings for the particular shape identified. Center Point Load Test of Pedestal-supported Slabs: 1,800 lbs. 3.1 Test Results: Documentation for the test results is on file and available upon request. 3.2 Technical Services: Technical service representatives are available to assist with project design, paver selection, installation recommendations, or any other technical concerns you may have. Contact: ABBOTSFORD CONCRETE PRODUCTS Toll free at Submittals: Two matched samples shall be used to determine the color and texture, one to be retained by the specifier, and the other by the manufacturer, to ensure the correct paver is provided to the project. 5.0 Installation: Qualified installers must show successful completion of three (3) similar sized project applications within the last three (3) years. The installer shall assign mechanics from these earlier applications, one of whom shall serve as lead mechanic. Installers not meeting this criteria shall require approval from the specifier or manufacturer prior to installation. 6.0 Maintenance: This product requires low maintenance. As the product is removable, it allows for easy maintenance to substrate as well as easy replacement of damaged pavers. A high-pressure wash is recommended from time to time, with drains being cleaned regularly. 7.0 Warranty: Abbotsford Concrete Products provides a manufacturer s warranty ensuring material specification compliance. Manufactured by Toll Free: Visit our website at for complete design details and photo gallery

HydraPressed Slabs. Yorkstone Tan. Where function meets style

HydraPressed Slabs. Yorkstone Tan. Where function meets style HydraPressed Slabs Yorkstone Tan Where function meets style Texada This series is named after the rugged and beautiful Gulf Islands of the Pacific Northwest. Texada HydraPressed Slabs have a light shot-blast

More information

HydraPressed Slabs. Yorkstone Tan. Where function meets style

HydraPressed Slabs. Yorkstone Tan. Where function meets style HydraPressed Slabs Yorkstone Tan Where function meets style Texada This series is named after the rugged and beautiful Gulf Islands of the Pacific Northwest. Texada HydraPressed Slabs have a light shot-blast

More information

PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS

PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS SECTION 32 14 13.16 PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS (1995 MasterFormat Section 02784) Note: This guide specification for the U.S. is for paving slabs used as ballast and/or paving on

More information

PERMEABLE PAVERS PHYSICAL AND GEOMETRICAL CHARACTERISTICS - PAVERS DRIVEWAYS, PERMEABLE DRIVEWAYS & PATIOS CHARACTERISTICS CSA A231.

PERMEABLE PAVERS PHYSICAL AND GEOMETRICAL CHARACTERISTICS - PAVERS DRIVEWAYS, PERMEABLE DRIVEWAYS & PATIOS CHARACTERISTICS CSA A231. DRIVEWAYS, DRIVEWAYS & PATIOS PHYSICAL AND GEOMETRICAL CHARACTERISTICS - CHARACTERISTICS CSA A231.2 TECHO-BLOC Compressive strength 50 MPa [7200 psi] min. 50 MPa [7200 psi] min. Absorption - 5 % max. Freeze-thaw

More information

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM SECTION 07555 PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM PART ONE: GENERAL 1.1 SUMMARY A. Concrete paver and pedestal support system with Lok Down devices are to be placed over roofing/waterproofing

More information

GUIDE SPECIFICATIONS FOR CONSTRUCTION OF THE AQUAPAVE PERMEABLE ON-SITE STORMWATER SOURCE CONTROL SYSTEM

GUIDE SPECIFICATIONS FOR CONSTRUCTION OF THE AQUAPAVE PERMEABLE ON-SITE STORMWATER SOURCE CONTROL SYSTEM GUIDE SPECIFICATIONS FOR CONSTRUCTION OF THE AQUAPAVE PERMEABLE ON-SITE STORMWATER SOURCE CONTROL SYSTEM SECTION 32 14 13.19 AQUAPAVE PERMEABLE INTERLOCKING CONCRETE PAVEMENT Note: This guide specification

More information

CONCRETE TILE PAVERS

CONCRETE TILE PAVERS Section 32 14 13 CONCRETE TILE PAVERS (1995 MasterFormat Section 02780) Note: This guide specification for the U.S. is for the installation of concrete tile paving units whose thickness are less than the

More information

Reinforced California Architectural Roof Pavers, Pedestal Supported

Reinforced California Architectural Roof Pavers, Pedestal Supported The following specification refers to the Stepstone, Inc. product known as: Reinforced California Architectural Roof Pavers, Pedestal Supported Stepstone, Inc. also manufactures California Architectural

More information

EverGuard Plaza Deck Roofing For Above-Grade Plaza Deck Applications

EverGuard Plaza Deck Roofing For Above-Grade Plaza Deck Applications EverGuard Plaza Deck Roofing For Above-Grade Plaza Deck Applications Specifications Updated: 12/07 Quality You Can Trust Since 1886... From North America s Largest Roofing Manufacturer PLAZA DECK ROOFING

More information

1. Concrete pavers, with ungrouted joints, over sand base. a. Large precast sections in random mix with smaller concrete pavers

1. Concrete pavers, with ungrouted joints, over sand base. a. Large precast sections in random mix with smaller concrete pavers SECTION 32 14 00 - PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specifications Sections, apply

More information

CHARACTERISTICS CSA A TECHO-BLOC Compressive strength psi [45 MPa] min.

CHARACTERISTICS CSA A TECHO-BLOC Compressive strength psi [45 MPa] min. PATIOS, WALKWAYS, POOLSIDES & STEPPING STONES PHYSICAL AND GEOMETRICAL CHARACTERISTICS CHARACTERISTICS CSA A231.1 2 TECHO-BLOC Compressive strength - 6 500 psi [45 MPa] min. Flexural strength 650 psi [4.5

More information

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers. SECTION 071413 HOT FLUID APPLIED RUBBERIZED ASPHALT WATERPROOFING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels.

More information

PERMEABLE INTERLOCKING PAVERS

PERMEABLE INTERLOCKING PAVERS PERMEABLE INTERLOCKING PAVERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subgrade Preparation B. Placement of Storage Aggregate C. Placement of Filter Aggregate D. Placement of Bedding Course E. Placement

More information

BMP 6.4.4: Infiltration Trench

BMP 6.4.4: Infiltration Trench BMP 6.4.4: Infiltration Trench An Infiltration Trench is a leaky pipe in a stone filled trench with a level bottom. An Infiltration Trench may be used as part of a larger storm sewer system, such as a

More information

CONSTRUCTION SPECIFICATION FOR CONCRETE UNIT PAVERS

CONSTRUCTION SPECIFICATION FOR CONCRETE UNIT PAVERS CITY OF TORONTO STANDARD CONSTRUCTION SPECIFICATIONS FOR ROADS TS 3.80 November 2010 CONSTRUCTION SPECIFICATION FOR CONCRETE UNIT PAVERS INDEX TS 3.80.01 SCOPE... 2 TS 3.80.02 REFERENCES... 2 TS 3.80.03

More information

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795) SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795) Note: This guide specification for U.S. applications describes construction of permeable interlocking concrete

More information

Construction Specification for Concrete Unit Pavers

Construction Specification for Concrete Unit Pavers Engineering & Construction Services Division Standard Specifications for Road Works TS 3.80 September 2017 for Concrete Unit Pavers Table of Contents TS 3.80.01 SCOPE... 2 TS 3.80.02 REFERENCES... 2 TS

More information

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1.

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1. 07555 - ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART 1.00 - GENERAL 1.01 SUMMARY: A. The work of this section consists of furnishing and installing

More information

PAVING SLABS ON A CONCRETE BASE

PAVING SLABS ON A CONCRETE BASE SECTION 32 14 13.16 PAVING SLABS ON A CONCRETE BASE (1995 MasterFormat Section 02784) Note: This guide specification for the U.S. is for paving slabs on a sand bed over concrete for pedestrian applications.

More information

SECTION TRENCHING

SECTION TRENCHING SECTION 31 23 17 TRENCHING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Excavating trenches for utilities and utility structures. 2. Bedding. 3. Backfilling and compacting to subgrade elevations.

More information

BITUMEN-SET PRECAST CONCRETE PAVING SLABS

BITUMEN-SET PRECAST CONCRETE PAVING SLABS SECTION 32 14 13.16 BITUMEN-SET PRECAST CONCRETE PAVING SLABS (1995 MasterFormat Section 02784) NOTE: This guide specification is the U.S. for concrete paving slabs adhered with a neoprene mastic to a

More information

CHARACTERISTICS CSA A TECHO-BLOC Compressive strength 50 MPa [7200 psi] min. 50 MPa [7200 psi] min.

CHARACTERISTICS CSA A TECHO-BLOC Compressive strength 50 MPa [7200 psi] min. 50 MPa [7200 psi] min. DRIVEWAYS, DRIVEWAYS & PATIOS PHYSICAL AND GEOMETRICAL CHARACTERISTICS CHARACTERISTICS CSA A231.2 2 TECHO-BLOC Compressive strength 50 MPa [7200 psi] min. 50 MPa [7200 psi] min. Freeze-thaw durability

More information

A.2.a Random Riprap... Table

A.2.a Random Riprap... Table 3601 RIPRAP MATERIAL 3601.1 SCOPE Provide stone and filter layer material for use in random or hand-placed riprap, gabion, and revet mattress construction. 3601.2 REQUIREMENTS A Stones A.1 Quality Provide

More information

Narrow Modular Pavers (NMP) for Sand-Set Installations

Narrow Modular Pavers (NMP) for Sand-Set Installations The following specification refers to the Stepstone, Inc. product known as: Narrow Modular Pavers (NMP) for Sand-Set Installations Narrow Modular Pavers are part of the California Architectural Paver line

More information

PERMEABLE INTERLOCKING CONCRETE PAVEMENT

PERMEABLE INTERLOCKING CONCRETE PAVEMENT [NOTE TO SPECIFICATION WRITER: This guide specification for the use of permeable interlocking concrete pavers for pedestrian and vehicular traffic application was developed based on the use of an open-graded

More information

ICPI TECH SPEC NUMBER 2 Construction of Interlocking Concrete Pavements

ICPI TECH SPEC NUMBER 2 Construction of Interlocking Concrete Pavements Page 1 of 6 ICPI TECH SPEC NUMBER 2 Construction of Interlocking Concrete Pavements 1995 ICPI Tech Spec No. 2 Interlocking Concrete Pavement Institute Revised May 2007 All rights reserved. Adequate compaction

More information

SECTION STORM DRAINAGE

SECTION STORM DRAINAGE SECTION 02720 STORM DRAINAGE PART 1 - GENERAL 1.01 WORK INCLUDED A. Trenching and other excavation. B. Ground water control. C. Pipe bedding. D. Installation of storm drains and appurtenances. E. Installation

More information

4.8. Subsurface Infiltration

4.8. Subsurface Infiltration 4.8. Subsurface Infiltration Subsurface infiltration systems are designed to provide temporary below grade storage infiltration of stormwater as it infiltrates into the ground. Dry wells, infiltration

More information

Pervious Concrete and Construction

Pervious Concrete and Construction Pervious Concrete and Construction International Concrete Sustainability Conference Dubai, December 2010 2010 International Concrete Sustainability Conference, Dubai, UAE 1 Pervious Concrete Concrete with

More information

4.8. Subsurface Infiltration

4.8. Subsurface Infiltration 4.8. Subsurface Infiltration Subsurface infiltration systems are designed to provide temporary below grade storage infiltration of storm water as it infiltrates into the ground. Dry wells, infiltration

More information

SECTION INTERLOCKING CONCRETE PAVERS

SECTION INTERLOCKING CONCRETE PAVERS SECTION 23 14 13 INTERLOCKING CONCRETE PAVERS (1995 MasterFormat Section 02780) Note: This guide specification for concrete paver applications in the U.S. for concrete pavers and bedding sand over a compacted

More information

SECTION PAVING SLABS ON AN AGGREGATE BASE

SECTION PAVING SLABS ON AN AGGREGATE BASE SECTION 32 14 13.16 PAVING SLABS ON AN AGGREGATE BASE (1995 MasterFormat Section 02784) NOTE: This guide specification for the U.S. is for paving slabs on a sand bed over a compacted aggregate base for

More information

SECTION PAVING SLABS ON AN AGGREGATE BASE

SECTION PAVING SLABS ON AN AGGREGATE BASE SECTION 32 14 13.16 PAVING SLABS ON AN AGGREGATE BASE (1995 MasterFormat Section 02784) NOTE: This guide specification for the U.S. is for paving slabs on a sand bed over a compacted aggregate base for

More information

Permeable Pavement. Pavements constructed with these units create joints that are filled with permeable

Permeable Pavement. Pavements constructed with these units create joints that are filled with permeable Permeable Permeable pavement is a paving system which allows rainfall to percolate through the surface into the underlying soil or an aggregate bed, where stormwater is stored and infiltrated to underlying

More information

SPECIAL SPECIFICATION 3504 Septic Tank System

SPECIAL SPECIFICATION 3504 Septic Tank System 1993 Specifications CSJ s 3136-01-126, etc. & 0683-01-070, etc. SPECIAL SPECIFICATION 3504 Septic Tank System 1. Description. This Item shall govern for all materials, equipment and labor necessary for

More information

SECTION ROOF PEDESTAL PAVER SYSTEM

SECTION ROOF PEDESTAL PAVER SYSTEM SECTION 07 76 00 ROOF PEDESTAL PAVER SYSTEM ************************************************************************************************************************ Edit entire master to suit project requirements.

More information

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork. PAGE 334000-1 SECTION 334000 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

Narrow Modular Pavers (NMP) for Mortar-Set Concrete Tiling Installations

Narrow Modular Pavers (NMP) for Mortar-Set Concrete Tiling Installations The following specification refers to the Stepstone, Inc. product known as: Narrow Modular Pavers (NMP) for Mortar-Set Concrete Tiling Installations Narrow Modular Pavers are part of the California Architectural

More information

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular

More information

A. Division 01 Specification Sections, Drawings, General Conditions, Supplementary General Conditions, and Special Conditions apply to this section.

A. Division 01 Specification Sections, Drawings, General Conditions, Supplementary General Conditions, and Special Conditions apply to this section. Note: This guide specification for U.S. applications is for concrete grid units placed on a sand bedding course over a compacted dense-graded aggregate base. The text allows an option of topsoil and grass

More information

MagnumStone Specifications Gravity

MagnumStone Specifications Gravity MagnumStone Specifications Gravity SPECIFICATION FOR MAGNUMSTONE GRAVITY MECHANICALLY STABILIZED EARTH SYSTEM PART 1: GENERAL.01Description The work consists of supplying and installing all aspects of

More information

Permeable Interlocking Concrete Pavements

Permeable Interlocking Concrete Pavements Permeable Interlocking Concrete Pavements Program 000003 Revised 1-29-08 Permeable Interlocking Concrete Pavements This program is registered with the AIA/CES and ASLA CPE for continuing education professional

More information

BAYFILTER SPECIFICATIONS

BAYFILTER SPECIFICATIONS PART 1.00 GENERAL 1.1 DESCRIPTION BAYFILTER SPECIFICATIONS A. The BayFilter system s internal components manufacturer selected by the Contractor and approved by the Engineer, shall furnish all labor, materials,

More information

A. Modular Unit - A concrete wall interlocking element, machine made from portland cement, water and aggregates.

A. Modular Unit - A concrete wall interlocking element, machine made from portland cement, water and aggregates. Section 02832 - Page 1 PART 1 - GENERAL 1.1 SUMMARY 1.2 DEFINITIONS 1.3 SUBMITTALS 1.4 JOB MOCK-UP A. This section includes furnishing and installation of modular interlocking concrete masonry units bearing

More information

TURFSTONE PAVERS SECTION CONCRETE GRID PAVEMENTS (1995 MasterFormat Section 02795)

TURFSTONE PAVERS SECTION CONCRETE GRID PAVEMENTS (1995 MasterFormat Section 02795) TURFSTONE PAVERS SECTION 32 14 13.19 CONCRETE GRID PAVEMENTS (1995 MasterFormat Section 02795) Note: This guide specification for U.S. applications is for concrete grid units placed on a sand bedding course

More information

Specification Guide and Installation Overview

Specification Guide and Installation Overview Specification Guide and Installation Overview PART ONE GENERAL 1.1 SCOPE OF WORK Provide materials, labor, transportation, services and equipment necessary to supply and install Xeripave or Xeribrix as

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 02630 - STORM DRAINAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Inflow pipe. Drain. Drain

Inflow pipe. Drain. Drain Inflow pipe Screened overflow Drain Foul flush diverter Screened intake Manhole cover Maximum water level Seal Inspection cover Possible local drainage through screen Drain Bottom sloped Screened outlet

More information

SECTION CONCRETE PAVING SLABS SET IN MORTAR

SECTION CONCRETE PAVING SLABS SET IN MORTAR SECTION 32 14 13.16 CONCRETE PAVING SLABS SET IN MORTAR (1995 MasterFormat Section 02784) Note: This guide specification for the U.S. is for paving slabs mortared to a concrete base and grouted joints

More information

California Architectural Pavers for Mortar-Set Concrete Tiling Installations

California Architectural Pavers for Mortar-Set Concrete Tiling Installations The following specification refers to the Stepstone, Inc. product known as: California Architectural Pavers for Mortar-Set Concrete Tiling Installations Stepstone, Inc. also manufactures California Architectural

More information

PERVIOUS PAVEMENT. Alternative Names: Permeable Pavement, Porous Concrete, Porous Pavers

PERVIOUS PAVEMENT. Alternative Names: Permeable Pavement, Porous Concrete, Porous Pavers 4.1-a PERVIOUS PAVEMENT Alternative Names: Permeable Pavement, Porous Concrete, Porous Pavers DESCRIPTION Pervious pavement is any system comprised of a load bearing surface that allows for movement of

More information

C-1. Infiltration System

C-1. Infiltration System C-1. Infiltration System Design Objective An infiltration system captures surface stormwater runoff and allows it to infiltrate into the soil. This SCM is typically the work horse of a runoff volume match

More information

STORMCAPTURE. Installation Manual

STORMCAPTURE. Installation Manual STORMCAPTURE Installation Manual Introduction Site Preparation Delivery & Installation LinkSlabs Backfill Introduction StormCapture (shown in Figure 1) is a total stormwater management system. The highly-configurable

More information

SECTION INTERLOCKING CONCRETE PAVERS

SECTION INTERLOCKING CONCRETE PAVERS SECTION 32 14 13 INTERLOCKING CONCRETE PAVERS (1995 MasterFormat Section 02780) Note: This guide specification for concrete paver applications in the U.S. for concrete pavers and bedding sand over a compacted

More information

INTERLOCKING CONCRETE PAVERS SECTION 02780

INTERLOCKING CONCRETE PAVERS SECTION 02780 INTERLOCKING CONCRETE PAVERS SECTION 02780 NOTE: This is a guide specification for the construction of Tremron Interlocking Concrete Pavers and bedding sand over a dense-graded, compacted aggregate base.

More information

Installation Guidelines

Installation Guidelines 815 NE 172 nd Avenue Vancouver, WA 98684 877-694-0141 Installation Guidelines Installation steps include job planning, layout, excavating and preparing the soil subgrade, applying geotextiles (optional),

More information

PUBLIC WORKS STANDARD DETAILS

PUBLIC WORKS STANDARD DETAILS PUBLIC WORKS STANDARD DETAILS SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THE INFORMATION CONTAINED IN THESE STANDARDS IS ACCURATE. HOWEVER, THE CITY OF BRADENTON BEACH CANNOT ACCEPT RESPONSIBILITY FOR

More information

SECTION SEGMENTAL CONCRETE UNIT MASONRY RETAINING WALL MAXIMUM HEIGHT OF 5-0 HIGH

SECTION SEGMENTAL CONCRETE UNIT MASONRY RETAINING WALL MAXIMUM HEIGHT OF 5-0 HIGH DIVISION 32 EXTERIOR IMPROVEMENTS SECTION 32 32 23.13 SEGMENTAL CONCRETE UNIT MASONRY RETAINING WALL MAXIMUM HEIGHT OF 5-0 HIGH PART 1: GENERAL 1.01 Scope of Standards A. This standard provides general

More information

for Mortar-Set Concrete Tiling Installations

for Mortar-Set Concrete Tiling Installations The following specification refers to the Stepstone, Inc. product known as: Large Scale CalArc Pavers for Mortar-Set Concrete Tiling Installations Large Scale CalArc Pavers are part of the California Architectural

More information

Permeable Interlocking Concrete Pavements Selection, Design, Construction and Maintenance

Permeable Interlocking Concrete Pavements Selection, Design, Construction and Maintenance Permeable Interlocking Concrete Pavements Selection, Design, Construction and Maintenance R. J. Burak, P.Eng. Director of Engineering for the Interlocking Concrete Pavement Institute Paper prepared for

More information

GUIDE SPECIFICATION FOR CONSTRUCTION USING WILLOW CREEK CONCRETE PAVERS

GUIDE SPECIFICATION FOR CONSTRUCTION USING WILLOW CREEK CONCRETE PAVERS SECTION 23 14 13.13 INTERLOCKING CONCRETE PAVERS (1995 MasterFormat Section 2780) GUIDE SPECIFICATION FOR CONSTRUCTION USING WILLOW CREEK CONCRETE PAVERS Note: This guide specification for concrete paver

More information

Tasman Retaining Wall System

Tasman Retaining Wall System Tasman Retaining Wall System The Tasman Retaining Wall System incorporates purpose made corners and capping units to provide classical reconstructed stone retaining walls for any landscape situation. From

More information

TERRASTOP SYSTEM 2 RETAINING WALLS. Section Page 1 PART 1 - GENERAL 1.1 SUMMARY

TERRASTOP SYSTEM 2 RETAINING WALLS. Section Page 1 PART 1 - GENERAL 1.1 SUMMARY Section 02832 - Page 1 PART 1 - GENERAL 1.1 SUMMARY 1.2 DEFINITIONS 1.3 SUBMITTALS 1.4 JOB MOCK-UP A. This section includes furnishing and installation of modular interlocking concrete masonry units bearing

More information

SECTION CONCRETE GRID PAVEMENTS (1995 MasterFormat Section 02795)

SECTION CONCRETE GRID PAVEMENTS (1995 MasterFormat Section 02795) SECTION 32 14 13.19 CONCRETE GRID PAVEMENTS (1995 MasterFormat Section 02795) Note: This guide specification for U.S. applications is for concrete grid units placed on a sand bedding course over a compacted

More information

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems SECTION 02607-1 1.0 GENERAL 1.1 SCOPE: A. This section covers the work necessary for the construction of sanitary and storm system manholes, catch basins, and miscellaneous concrete structures complete.

More information

CENTRALIZED BMPS TYPICALLY PUBLICLY OWNED & MAINTAINED BMPS, TREATING A LARGE (>20 ACRES) URBAN DRAINAGE WITH MULTIPLE LAND

CENTRALIZED BMPS TYPICALLY PUBLICLY OWNED & MAINTAINED BMPS, TREATING A LARGE (>20 ACRES) URBAN DRAINAGE WITH MULTIPLE LAND BMP RAM BMP Type Definitions 1 CENTRALIZED BMPS TYPICALLY PUBLICLY OWNED & MAINTAINED BMPS, TREATING A LARGE (>20 ACRES) URBAN DRAINAGE WITH MULTIPLE LAND USES AND OWNERSHIP STRUCTURAL BMP TYPE OTHER NAMES

More information

1.1 RELATED DOCUMENTS

1.1 RELATED DOCUMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

SECTION CONCRETE GRID PAVEMENTS (Turfstone) (1995 MasterFormat Section 02795)

SECTION CONCRETE GRID PAVEMENTS (Turfstone) (1995 MasterFormat Section 02795) SECTION 32 14 13.19 CONCRETE GRID PAVEMENTS (Turfstone) (1995 MasterFormat Section 02795) Note: This guide specification for U.S. applications is for concrete grid units placed on a sand bedding course

More information

SECTION INTERLOCKING PRECAST CONCRETE UNIT PAVERS

SECTION INTERLOCKING PRECAST CONCRETE UNIT PAVERS SECTION 321413.13 INTERLOCKING PRECAST CONCRETE UNIT PAVERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Interlocking concrete paver units. 2. Sand setting bed. 3. Sand joint

More information

PERMECAPTURE DETENTION / RETENTION. The Smart Stormwater Management Solution. S ustainable B y D esign

PERMECAPTURE DETENTION / RETENTION. The Smart Stormwater Management Solution. S ustainable B y D esign PERMECAPTURE The Smart Stormwater Management Solution S uperior B y P erformance Call us today (800) 579-8819 or visit our website for detailed product information, drawings and design tools at www.oldcastlestormwater.com

More information

ROOF PAVER SYSTEM National Distribution SPEC - SECTION 07760

ROOF PAVER SYSTEM National Distribution SPEC - SECTION 07760 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

LS 2519 CONCRETE PAVER PAVEMENT RECONSTRUCTION

LS 2519 CONCRETE PAVER PAVEMENT RECONSTRUCTION LS 2519 CONCRETE PAVER PAVEMENT RECONSTRUCTION A. Section Includes B. References C. Quality Assurance D. Submittals E. Delivery, Storage and Handling F. Environmental Conditions G. Summary H. Concrete

More information

SECTION PAVING SLABS ON AN AGGREGATE BASE

SECTION PAVING SLABS ON AN AGGREGATE BASE Phone 905-655-3311 1-800-655-3430 Email brooklinsales@brooklin.com CAN-slabs on agg base.doc Phone 905-655-3311 1-800-655-3430 Email brooklinsales@brooklin.com SECTION 32 14 13.16 PAVING SLABS ON AN AGGREGATE

More information

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1 Section 7 Roadway GENERAL REQUIREMENTS...7-1 I. TYPICAL SECTION...7-1 7.1 LANE WIDTHS...7-1 7.2 SHOULDER WIDTHS...7-1 7.3 CROSS SLOPE...7-2 7.4 CURB AND UNDERDRAINS...7-2 7.5 SIDEWALKS AND DRIVEWAYS...7-2

More information

SECTION 1 BIO-INFILTRATION BUMP OUTS (BIBO)

SECTION 1 BIO-INFILTRATION BUMP OUTS (BIBO) SECTION 1 BIO-INFILTRATION BUMP OUTS (BIBO) This guide specification for U.S. applications describes construction of bio-infiltration bump outs (or bioretention ) systems. From the surface down to the

More information

Construction Inspection Checklists

Construction Inspection Checklists III. Construction Inspection Checklists 33 Bioretention - Construction Inspection Checklist Project: Location: Site Status: Date: Time: Inspector: Construction Sequence Satisfactory / Unsatisfactory Comments

More information

BIO-AQUIFER STORM SYSTEM

BIO-AQUIFER STORM SYSTEM BIO-AQUIFER STORM SYSTEM Specifications for Construction PART 1 GENERAL 1.01 SECTION INCLUDES A. Providing labor, materials, tools and equipment to furnish and install a permeable concrete paving stone

More information

SECTION RIGID PAVEMENT

SECTION RIGID PAVEMENT SECTION 02750 PART 1 GENERAL RIGID PAVEMENT 1.1 SUMMARY A. Section Includes: 1. Concrete sidewalks. 2. Concrete stair steps. 3. Concrete integral curbs gutters. 4. Concrete parking areas and roads. B.

More information

Summary of the 2011 Changes

Summary of the 2011 Changes The following is a list of amendments to the Residential Site Improvement s, N.J.A.C. 5:21, adopted in 2011. The Notice of Adoption of these changes appeared in the New Jersey Register on May 16, 2011.

More information

SECTION INTERLOCKING CONCRETE PAVEMENT ON A CEMENT TREATED BASE

SECTION INTERLOCKING CONCRETE PAVEMENT ON A CEMENT TREATED BASE SECTION 32 14 13 INTERLOCKING CONCRETE PAVEMENT ON A CEMENT TREATED BASE (1995 MasterFormat Section 02780) Note: This guide specification for the U.S. is for concrete pavers on a sand bed with geotextile

More information

Construction Specification for Utility Adjustments

Construction Specification for Utility Adjustments Engineering & Construction Services Division Standard Specifications for Road Works TS 4.50 September 2017 for Utility Adjustments Table of Contents TS 4.50.01 SCOPE... 2 TS 4.50.02 REFERENCES... 2 TS

More information

INSTALLATION GUIDE SLABS

INSTALLATION GUIDE SLABS INSTALLATION OUTLINE techo-bloc.com 01 EXCAVATION A. Before excavating, call all the local utility companies (e.g., phone, gas, electrical) to ensure that the area in which you plan to dig is clear of

More information

WQ-08 ENHANCED DRY SWALE

WQ-08 ENHANCED DRY SWALE Greenville County Technical Specification for: WQ-08 ENHANCED DRY SWALE 1.0 Enhanced Dry Swale 1.1 Description An Enhanced Dry Swale is a shallow open-channel drainage way stabilized with turf grass or

More information

Permeable Pavement Facilities and Surfaces

Permeable Pavement Facilities and Surfaces Permeable Pavement Facilities and Surfaces This checklist is intended to highlight items critical to the performance of permeable pavement facilities and surfaces that need to be addressed in the design

More information

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage. DELTA -DRAIN 6200 Section 07 10 00 Dampproofing and Waterproofing PART 1 GENERAL 1.1 SECTION INCLUDES A. Below grade waterproofing. B. Below grade drainage sheets. C. Plaza deck and planter drainage sheets.

More information

SECTION STORM DRAINAGE. A. This Section includes gravity-flow, nonpressure storm drainage (REMOVED), with the following components:

SECTION STORM DRAINAGE. A. This Section includes gravity-flow, nonpressure storm drainage (REMOVED), with the following components: SECTION 02630 STORM DRAINAGE PART - GENERAL. SUMMARY A. This Section includes gravity-flow, nonpressure storm drainage (REMOVED), with the following components:. Cleanouts. 2. Precast concrete manholes.

More information

4.28 Underground Detention

4.28 Underground Detention 4.28 Underground Detention Detention Structural Stormwater Control Description: Detention storage located in underground tanks or vaults designed to provide water quantity control through detention and/or

More information

10 EXTREME BASEMENT PANELS

10 EXTREME BASEMENT PANELS 10 EXTREME BASEMENT PANELS On Granular Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions. Soils are classified

More information

PAVING OVER PROBLEM SUBSTRATES FOR ROOF DECK PROJECTS

PAVING OVER PROBLEM SUBSTRATES FOR ROOF DECK PROJECTS PAVING OVER PROBLEM SUBSTRATES FOR ROOF DECK PROJECTS SUMMARY Mark Smallridge, PE Mark Smallridge and Associates, Inc. 3524 Cottonwood Springs Drive The Colony, TX 75056 Tel: 972 624 8817 Fax: 972 624

More information

CONCRETE ROOF BALLAST SLABS PRODUCT GUIDE

CONCRETE ROOF BALLAST SLABS PRODUCT GUIDE PRODUCT GUIDE INNOVATIVE ROOF SLABS CREATE FUNCTIONAL AND ATTRACTIVE SPACES Versatile Superior quality Cost-effective BALLAST-LOK CONCRETE ROOF SLABS Brooklin s Ballast-Lok concrete roof slabs and locking

More information

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved SECTION 22 14 00 - PLUMBING DRAINAGE AND CONTAINMENT Copyright 1998-2017 Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. SLOT shaped, non-grated,

More information

SECTION UTILITY MANHOLES AND STRUCTURES

SECTION UTILITY MANHOLES AND STRUCTURES SECTION 33 05 14 UTILITY MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Precast reinforced concrete manholes and structures with tongue-and-groove joints with masonry transition

More information

SECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation

SECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation SECTION 33 40 00 STORM DRAINAGE UTILITIES 1. PART 1 GENERAL 1.1 RELATED WORK A. Section 31 23 00: Excavation and Fill B. Section 32 00 01: Site Restoration and Rehabilitation C. Special Conditions for

More information

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 9/17/18)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 9/17/18) Page 1 of 8 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks

More information

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION 075000 ROOFING SYSTEMS PART 1 - GENERAL 1.1. Any deviation from the following instructions must be approved during design by WVU Facilities Management Personnel. 1.2. DEFINITIONS A. ASTM American Society

More information

INSTALLATION OUTLINE INTERLOCKING CONCRETE PAVEMENT 01 EXCAVATION 02 FOUNDATION 03 THE SETTING BED 04 INSTALLATION OF PAVING STONES

INSTALLATION OUTLINE INTERLOCKING CONCRETE PAVEMENT 01 EXCAVATION 02 FOUNDATION 03 THE SETTING BED 04 INSTALLATION OF PAVING STONES INTERLOCKING CONCRETE PAVEMENT INSTALLATION OUTLINE 01 EXCAVATION A. Before excavating, call all the local utility companies (e.g., phone, gas, electrical) to ensure that the area in which you plan to

More information

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1 CHAPTER 17: STORM SEWER STANDARDS 17.00 Introduction 17.01 Administration 17.02 Standards 17.1 17.00 INTRODUCTION The purpose of this chapter is to provide guidance for the design and construction of storm

More information

Tasman Retaining Wall System

Tasman Retaining Wall System Tasman Retaining Wall System The Tasman Retaining Wall System incorporates purpose made corners and capping units to provide classical reconstructed stone retaining walls for any landscape situation. From

More information

INSTALLATION GUIDE INSTALLATION OUTLINE INTERLOCKING CONCRETE PAVEMENT 01 EXCAVATION 02 FOUNDATION 03 THE SETTING BED 04 INSTALLATION OF PAVING STONES

INSTALLATION GUIDE INSTALLATION OUTLINE INTERLOCKING CONCRETE PAVEMENT 01 EXCAVATION 02 FOUNDATION 03 THE SETTING BED 04 INSTALLATION OF PAVING STONES INTERLOCKING CONCRETE PAVEMENT INSTALLATION OUTLINE 01 EXCAVATION A. Before excavating, call all the local utility companies (e.g., phone, gas, electrical) to ensure that the area in which you plan to

More information

WQ-06 SAND FILTER. 1.0 Sand Filter. Greenville County Technical Specification for: 1.1 Description

WQ-06 SAND FILTER. 1.0 Sand Filter. Greenville County Technical Specification for: 1.1 Description Greenville County Technical Specification for: WQ-06 SAND FILTER 1.0 Sand Filter 1.1 Description Sand Filters remove pollutants through sedimentation and filtration within the sand. The primary components

More information