Excerpts from: International Residential Code 2009

Size: px
Start display at page:

Download "Excerpts from: International Residential Code 2009"

Transcription

1 LUMBER & MILLWORK Excerpts from: International Residential Code 2009 R310.1 Emergency escape and rescue required. Basements, habitable attics and every sleeping room shall have at least one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room. Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with Section R The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with Section R Emergency escape and rescue openings shall open directly into a public way, or to a yard or court that opens to a public way. Exception: Basements used only to house mechanical equipment and not exceeding total floor area of 200 square feet (18.58 m2). R Minimum opening area. All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.530 m2). Exception: Grade floor openings shall have a minimum net clear opening of 5 square feet (0.465 m2). R Minimum opening height. The minimum net clear opening height shall be 24 inches (610 mm). International Residential Code Emergency Egress Minimum Opening Size 20 minimum AREA = 5.7 square feet 24 minimum 44 finished floor to top of stool cap maximum The lowest part of the clear opening of the window shall be a minimum of 24 above the finished floor. Finished Floor R Minimum opening width. The minimum net clear opening width shall be 20 inches (508 mm). R Operational constraints. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys, tools, or special knowledge NOTE: For casement egress sizes refer to product catalogs Excerpts from: State Board of Building Regulations and Standards Massachusetts 8th Edition Building Code EMERGENCY ESCAPE AND RESCUE OPENINGS R310.1 Emergency Escape and Rescue Required. Basements with habitable space and every sleeping room shall have at least one openable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with 780 CMR The net clear opening dimensions required by 780 CMR5310 shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with 780 CMR R Minimum Opening Area. All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.530 m2). 1. Grade floor openings shall have a minimum net clear opening of five square feet (0.465 m2). 2. Double hung windows used for emergency escape shall be permitted to have a net clear opening of 3.3 square feet (0.31 m2) provided that at least one operable sash meets the minimum heightand width required by 780 CMR and and operational constraints defined by 780 CMR R Minimum Opening Height. The minimum net clear opening height shall be 24 inches (610 mm). R Minimum Opening Width. The minimum net clear opening width shall be 20 inches (508 mm). R Operational Constraints. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. R303.1 Habitable Rooms. All habitable rooms shall be provided with aggregate glazing area of not less than 8 percent of the floor area of such rooms. Natural ventilation shall be through windows, doors, louvers or other Massachussetts Emergency Egress Minimum Opening Size 36 March minimum AREA = 3.3 square feet D.H. only Casement = 5.7 sq. ft. 24 minimum 44 finished floor to top of stool cap maximum The lowest part of the clear opening of the window shall be a minimum of 18 above the finished floor. Finished Floor approved openings to the outdoor air. Such openings shall be provided with ready access or shall otherwise be readily controllable by the building occupants. The minimum openable area to the outdoors shall be 4 percent of the floor area being ventilated. Exception: 1. The glazed areas need not be openable where the opening is not required by Section R310 and an approved mechanical ventilation system is provided capable of producing 0.35 air change per hour in the room or a whole-house mechanical ventilation system is installed capable of supplying outdoor ventilation air of 15 cubic feet per-minute (cfm) (7.08L/s) per occupant computed on the basis of two occupants for the first bedroom and one occupant for each additional bedroom. 2. The glazed areas need not be provided in rooms where Exception 1 above is satisfied and artificial light is provided capable of producing an average illumination of 6 foot candles (6.46 lux) over the area of the room at a height of 30 inches (762 mm) above the floor level. 3. Use of sunroom additions and patio covers, as defined in Section R202, shall be permitted for natural ventilation if in excess of 40 percent of the exterior sunroom walls are open, or are enclosed only by insect screening

2 LUMBER & MILLWORK Excerpts from: International Residential Code 2009 and Massachusetts State Building Code One & Two Family Dwelling 8th Edition Garage Fire Doors R Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 13 8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 13 8 inches (35 mm) thick, or 20-minute fire-rated doors. R311.1 Means of egress. All dwellings shall be provided with a means of egress as provided in this section. The means of egress shall provide a continuous and unobstructed path of vertical and horizontal egress travel from all portions of the dwelling to the exterior of the dwelling at the required egress door without requiring travel through a garage. R311.2 Egress door. At least one egress door shall be provided for each dwelling unit. The egress door shall be side-hinged, and shall provide a minimum clear width of 32 inches (813 mm) when measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). The minimum clear height of the door opening shall not be less than 78 inches (1981 mm) in height measured from the top of the threshold to the bottom of the stop. Other doors shall not be required to comply with these minimum dimensions. Egress doors shall be readily openable from inside the dwelling without the use of a key or special knowledge or effort. R308.4 Hazardous locations. The following shall be considered specific hazardous locations for the purposes of glazing: 1. Glazing in all fixed and operable panels of swinging, sliding and bifold doors. 1. Glazed openings of a size through which a 3-inch diameter (76 mm) sphere is unable to pass. 2. Decorative glazing. 3. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24-inch (610 mm) arc of the door in a closed position and whose bottom edge is less than 60 inches (1524 mm) above the floor or walking surface. 1. Decorative glazing. 2. When there is an intervening wall or other permanent barrier between the door and the glazing. 3. Glazing in walls on the latch side of and perpendicular to the plane of the door in a closed position. 4. Glazing adjacent to a door where access through the door is to a closet or storage area 3 feet (914 mm) or less in depth. 5. Glazing that is adjacent to the fixed panel of patio doors. 3. Glazing in an individual fixed or operable panel that meets all of the following conditions: 3.1. The exposed area of an individual pane is larger than 9 square feet (0.836 m2); and 3.2. The bottom edge of the glazing is less than 18 inches (457 mm) above the floor; and 3.3. The top edge of the glazing is more than 36 inches (914 mm) above the floor; and 3.4. one or more walking surfaces are within 36 inches (914 mm), measured horizontally and in a straight line, of the glazing. 1. Decorative glazing. 2. When a horizontal rail is installed on the accessible side(s) of the glazing 34 to 38 inches (864 to 965) above the walking surface. The rail shall be capable of withstanding a horizontal load of 50 pounds per linear foot (730 N/m) without contacting the glass and be a minimum of 11/2 inches (38 mm) in cross sectional height. 3. outboard panes in insulating glass units and other multiple glazed panels when the bottom edge of the glass is 25 feet (7620 mm) or more above grade, a roof, walking surfaces or other horizontal [within 45 degrees (0.79 rad) of horizontal] surface adjacent to the glass exterior. 4. All glazing in railings regardless of area or height above a walking surface. Included are structural baluster panels and nonstructural infill panels. 5. Glazing in enclosures for or walls facing hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers where the bottom exposed edge of the glazing is less than 60 inches (1524 mm) measured vertically above any standing or walking surface. Exception: Glazing that is more than 60 inches (1524 mm), measured horizontally and in a straight line, from the waters edge of a hot tub, whirlpool or bathtub. 6. Glazing in walls and fences adjacent to indoor and outdoor swimming pools, hot tubs and spas where the bottom edge of the glazing is less than 60 inches (1524 mm) above a walking surface and within 60 inches (1524 mm), measured horizontally and in a straight line, of the water s edge. This shall apply to single glazing and all panes in multiple glazing. 7. Glazing adjacent to stairways, landings and ramps within 36 inches (914 mm) horizontally of a walking surface when the exposed surface of the glazing is less than 60 inches (1524 mm) above the plane of the adjacent walking surface. 1. When a rail is installed on the accessible side(s) of the glazing 34 to 38 inches (864 to 965 mm) above the walking surface. The rail shall be capable of withstanding a horizontal load of 50 pounds per linear foot (730 N/m) without contacting the glass and be a minimum of 11/2 inches (38 mm) in cross sectional height. 2. The side of the stairway has a guardrail or handrail, including balusters or in-fill panels, complying with Sections R and R312 and the plane of the glazing is more than 18 inches (457 mm) from the railing; or 3. When a solid wall or panel extends from the plane of the adjacent walking surface to 34 inches (863 mm) to 36 inches (914 mm) above the walking surface and the construction at the top of that wall or panel is capable of withstanding the same horizontal load as a guard. 8. Glazing adjacent to stairways within 60 inches (1524 mm) horizontally of the bottom tread of a stairway in any direction when the exposed surface of the glazing is less than 60 inches (1524 mm) above the nose of the tread. 1. The side of the stairway has a guardrail or handrail, including balusters or in-fill panels, complying with Sections R and R312 and the plane of the glass is more than 18 inches (457 mm) from the railing; or 2. When a solid wall or panel extends from the plane of the adjacent walking surface to 34 inches (864 mm) to 36 inches (914 mm) above the walking surface and the construction at the top of that wall or panel is capable of withstanding the same horizontal load as a guard. R311.1 and R311.2 R311.1 Means of Egress. All dwellings shall be provided with two means of egress as provided in this section. The means of egress shall provide a continuous and unobstructed path of vertical and horizontal egress travel from all portions of the dwelling to the exterior of the dwelling at the required egress doors without requiring travel through a garage. For townhouses all see the Architectural Access Board s regulations at 521 CMR. Exception. Egress through the secondary egress door, required in subsectionr311.2, may include travel through garage provided the garage has an exit door meeting the requirements of a secondary egress door. R311.2 Egress Door. At least two egress doors shall be provided for each dwelling unit, remote as possible from each other, at the normal level of exit. 1. In multi-level dwellings, including but not limited to townhouse, split-level and raised ranch style layouts, the two separate egress doors requires by are permitted to be located on different levels. 2. Where site topography prevents direct access at two remote locations to grade from the normal level of entry, the two separate egress doors required by are permitted to be located on different levels. The primary egress door shall be side-hinged, and shall provide minimum clear width of 32 inch (813mm) when measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). The secondary egress door shall be side-hinged or sliding, and shall provide a minimum clear width of 28 inches (711mm) when measured between the face of the door and the stop, with the door open at 90 degrees (1.57 rad). The minimum clear height of the primary and secondary egress door opening shall not be less than 78 inches (1981mm) in height measured from to of the threshold to the bottom of the stop. Other exterior doors shall not be required to comply with these minimum dimensions. Egress doors shall be readily openable from inside the dwelling without the use of key or special knowledge or effort. March

3 20 Minute Rated Entry Doors LUMBER & MILLWORK Steel ISFD Standard Lock Prep 3'0" - 2 3/4" BS 2'8" - 2 3/8" BS Molded IWFD Standard Lock Prep All Widths 2-3 /8" BS Wood IWFD Standard Lock Prep 3'0" - 2 3/4" BS 2'8" - 2 3/8" BS Garage Fire Doors Flush 6 Panel 4 Panel MHD-2S MHD-2 3/0 2/6 2/8 3/0 Winslow 6PNL20MINSM 4PNL20MINSM 2PNL20MINSM 2/8, 3/0 2/6, 2/8, 3/0 2/8, 3/0 2/8, 3/0 Flat Panel Lincoln Park Logan Rockport Cheyenne Roman Flat Panel Flat Panel F9130 F9244 F /16 Fire Rated Raised Panel Ovolo Sticking F9220 F9282 3/4 Fire Rated Flat Panel Ovolo Sticking R Opening protection: Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and dwelling shall be equipped with either solid wood doors not less than 1-3 /4 inch (45 mm) in thickness or 20-minute fire-rated doors. Self closing devices and fire resistive rated door frames are not required. All door openings between the garage and the dwelling shall be provided with a raised sill with a minimum height of four inches. Local building codes may require self closing hinges and or fire rated jambs. Stock Standard Features for Frame: Primed FJ Jamb & Casing Premium Aluminum Sill Weatherstripped 4 x 4 STD Hinges US4 20 Minute Label Frame 4-3 /4 or 6-3 /4 Wall Thickness These maybe ripped down for narrower jamb requirements. 41 U Value Standard Lock Prep 2-6, 2-8= 2-3 /8 BS 3-0 = 2-3 /4 BS Options: Applied Interior Casings Oak Sill Oak Threshold Aluminum Threshold 1 Way Viewer 4 x 4 Self Closing Hinges Choice of Hardware Color Rough Openings: 2-6 x 6-8 R.O /2 x 82-1 /2 2-8 x 6-8 R.O /2 x 82-1 /2 3-0 x 6-8 R.O /2 x 82-1 /2 Rough opening with carpet shim 83 Label Affixed to Frame March

4 Interior Door Unit Rough Openings Single Door Bi-Fold Slider (Bi-Pass) Pair Cased Double Pocket Door Opening Acting 2-Door Units Specify Left Hand or Right Hand When Ordering * / / / / / /2 Left Hand Right Hand / /2 *26-1/2 26-1/2 * Available with Ball Catch Roller Latch Magnetic Catch T-Astragal w/ Head & Foot Bolt (must specify handing when ordering w/ T-Astragal) 26 1/ /2 28 1/ /2 *30-1/2 30-1/2 * 30-1/ /2 *32-1/2 32-1/2 * 32-1/2 32-1/ /2 *34-1/2 34-1/2 * 34-1/2 34-1/ /2 36-1/2 36-1/ /2 *38-1/2 38-1/2 * 38-1/2 38-1/ /2 * 42-1/ /2 44-1/ /2 * 46-1/ / /2 49-1/2 50-1/2 * /2 54-1/2 * /2 57-1/2 58-1/2 * /2 61-1/2 62-1/2 * /2 65-1/2 66-1/2 * /2 70-1/2 * /2 73-1/2 74-1/2 * * Note: Add 7/16 to UD unit pair when using T-AST In between sizes also available 50-1/ / / / / / /2 144 Interior Doors R Interior Doors: All doors providing access to habitable rooms shall have a minimum nominal width of 30 inches and a minimum nominal height of six feet six inches. 1. Doors providing access to bathrooms are permitted to be 28 inches in nominal width. 2. Existing Buildings: Doors providing access to bathrooms are permitted to be 24 inches in nominal width. Rough Opening Formula Add to Door Width Add to Door Height Interior Door 2-1/2 2-1/2 Bi-Fold 2-1/2 2-1/2 Slider (Bi-Pass) 1-1/2 2-1/2 Unit Pair 2-1/2 2-1/2 Cased Opening 2-1/2 2-1/2 Pocket Door Single (Door Width x 2) /2 Pocket Door Pair (Door Width x 4) 4-1/2 * All pre-hung door units are built with a 1-1 /8 clearance at the bottom of the door. 62 March 2016

5 Attic Scuttle R-6.7 Attic Scuttle 1" Foil/Foam BD 1/2" MDO PANEL " " Panel Options: 1/2" Oak 1/2" Birch 1/2" Bead Board Features for all Scuttles: 1/2 Primed MDO Panel Single Rabbet Jamb Compression Weather-stripping Casing 4 Sides (Picture Frame) Order by Rough Opening Maxmium Size is 80 U.I. U.I. = Sum of 1 Width & 1 Length CODE = APS R Attic Scuttle R-18.6 Attic Scuttle 3" 5-1/2" R Attic Scuttle R-37.2 Attic Scuttle 6" 9-1/4" R-55.8 Attic Scuttle R Attic Scuttle 9" 11-1/4" Access Panel " 1/2" MDO PANEL Features: 1/2 Primed MDO Panel 4-5/8 Finger Joint Primed Jamb Wood knob Lift & Pull to remove panel Order by Rough Opening 36 maxium width CODE = APS 41 maxium height Access to crawl spaces: Access shall be provided to crawl spaces by an opening not less than 18 inches by 24 inches. Options: Foam Insulation Board 1" = R " = R " = R 25.8 Weather-stripping Panel Options 1/2" Oak 1/2" Birch 1/2" Bead Board Casing Option 3 sides 4 sides R807.1 Attic Access. An attic access opening shall be provided to attic areas that exceed 30 square feet and have a vertical height of 30 inches or greater. The rough-framed opening shall not be less than 22 inches by 30 inches and shall be located in a hallway or other readily accessible location. A 30-inch minimum unobstructed headroom in the attic space shall be provided at some point above the access opening. See 780 CMR for access requirements where mechanical equipment is located in attics. All attic access doors, trap doors, etc., separating conditioned from unconditioned space shall be fitted with suitable gaskets, weather strips, etc., and fit and close tightly to ensure minimal air leakage between conditioned and unconditioned space (also see 780 CMR 61.00). 78 March 2016

6 Width Minimum width of stairs is normally 36. These codes usually do not include handrail projections, which are discussed at right. Note: For two people to pass comfortably and for allowance of the passage of furniture, 42 or wider stairs are recommended. Rail must be continous on full length of stairway. Headroom Minimum headroom codes vary but are generally measured vertically from the lowest portion of the ceiling to a point along the imaginary line connecting the tread nosings. C Hand Rail A 6" 6" B C A Winder A. Width of the tread at a point not more than 12 from side where tread is narrowest must be equal to the tread depth of a straight run tread. B. The minimum depth of any tread is no less than 6. C. The continuous rail must be on the side where the treads are narrowest. D. Rail must be continuous. E. Within any flight of stairs, the largest winder tread depth at 12 walk line shall not exceed the smallest by more than 3/8. Always check and understand local building codes before specifying ANY stair parts. 80 March 2016

7 Building Code Stairways 43/8 4 Min 36 Min 34 Max 38 Max 1-1/4 IRC MA Code 10 Min 9 Min Run Rake Rail Height Rake rail heights are measured from top of the leading edge of the nosing to the point at the top of the rail directly above. Baluster Spacing A sphere 4-3/8 in Dia. cannot pass through. Balcony Rail Height Balcony rail heights are measured from the finished floor surface to the top of the level rail. Baluster Spacing A sphere 4 in Dia. cannot pass through. IRC 7-3/4 Max MA Code 8-1/4 Max Rise The individual rise measurement of a stair is measured from tread surface to tread surface. Some codes continue by specifying the greatest individual rise within any stair should not exceed the smallest by more than 3/8. Individual tread run measurements are from riser line to riser line and do not include the overhang portion of the tread. In addition, most codes require a 3/4 to 1-1/4 tread overhang. Individual measurements of tread run (as well as measurements of tread overhang) cannot vary by more than 3/8 from the smallest to largest. Handrail Grip Size Round Rail 6 Min. 1-1/4 Dia. Max. 2 Dia. Min 1-1/2 Max 4-1/2 Profile Rail Max. Diameter 2-3/4 2 3/4" A related sphere code relates to a stair that uses shoe rail on an open stair. The size of the triangle formed by the tread, risers, and the bottom of the shoe rail is also governed by a sphere size, usually 6. Handrail Projection Projection of the handrail into the stair, measured from the edge of the rail to the wall, is generally listed at a maximum of 4-1/2. Handrail Clearance Handrails adjacent to a wall require a space between the wall and the handrail (usually not less than 1-1/2 ). This distance must also be kept between a handrail that passes the landing tread of a balcony rail section that returns on the stair. Always check and understand local building codes before specifying ANY stair parts. March

FRAMING INSPECTION GENERAL

FRAMING INSPECTION GENERAL FRAMING INSPECTION GENERAL 20 FRAMING INSPECTION GENERAL Tips Check habitable rooms for minimum light, ventilation and sanitation requirements. Check that stair framing meets headroom, width, and rise

More information

WINDOW AND DOOR REPLACEMENT SAMPLE PLAN

WINDOW AND DOOR REPLACEMENT SAMPLE PLAN To aid in communication between yourself, the inspectors, and the plans examiners, we have prepared this sample plan to assist in the preparations of your plan for window and door replacement. Follow the

More information

CITY OF DANA POINT WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS

CITY OF DANA POINT WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS CITY OF DANA POINT COMMUNITY DEVELOPMENT BUILDING AND SAFETY 33282 Golden Lantern, Suite 209 Dana Point, CA 92629 949 248-3594 www.danapoint.org WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS 2016 CALIFORNIA

More information

General Residential Code Requirements

General Residential Code Requirements General Residential Code Requirements Residential building code review will be based on compliance with the requirements of the Louisiana State Uniform Construction code in accordance with ACT 12 of the

More information

RESIDENTIAL STAIRWAYS, HANDRAILS,

RESIDENTIAL STAIRWAYS, HANDRAILS, City Of Austin 500 Fourth Avenue N.E. Austin, Minnesota 55912-3773 Building Department 507-437-9950 Fax 507-437-7101 RESIDENTIAL STAIRWAYS, HANDRAILS, *A Building permit is required for any alteration

More information

General Residential Code Requirements

General Residential Code Requirements General Residential Code Requirements Dear Applicant: This is to advise that our review will be based on compliance with the requirements of the Louisiana State Uniform Construction code in accordance

More information

General Residential Code Requirements

General Residential Code Requirements Residential building code review will be based on compliance with the requirements of the Louisiana State Uniform Construction code in accordance with ACT 12 of the 2005 First Extraordinary Session of

More information

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth.

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth. 311.7 Stairways. 311.7.1 Width. Stairways shall not be less than 36 inches (914 mm) in clear width at all points above the permitted handrail height and below the required headroom height. Handrails shall

More information

Inspection Checklist Residential Building Final July 2016

Inspection Checklist Residential Building Final July 2016 Inspection Checklist Residential Building Final July 2016 This Inspection Checklist reflects code requirements of the 2015 International Residential Code (IRC), 2015 Uniform Plumbing Code (UPC), 2014 National

More information

Minimum Requirements for Residential Occupancy Codes and FAQs

Minimum Requirements for Residential Occupancy Codes and FAQs City of McMinnville, Planning & Zoning Department 101 East Main, McMinnville, TN 37110 (931) 473-1204 Fax (931) 473-6231 Email: nming@mcminnvilletenn.com Minimum Requirements for Residential Occupancy

More information

BUILDING PERMIT APPLICATION

BUILDING PERMIT APPLICATION MASON COUNTY COMMUNITY SERVICES PERMIT ASSISTANCE CENTER: BUILDING PLANNING PUBLIC HEALTH FIRE MARSHAL 615 W. Alder Street, Shelton, WA 98584 Phone Shelton: (360)427-9670 ext. 352 Fax: (360)427-7798 Phone

More information

2018 IRC Sections R303 through R310 Building Planning II

2018 IRC Sections R303 through R310 Building Planning II Study Session 3 2018 IRC Sections R303 through R310 Building Planning II OBJECTIVE: REFERENCE: KEY POINTS: To develop an understanding of the health and safety criteria of the code, including light and

More information

RESIDENTIAL BUILDING REQUIREMENTS

RESIDENTIAL BUILDING REQUIREMENTS RESIDENTIAL BUILDING REQUIREMENTS Residential Building Requirements This is an informational booklet with some of the general residential construction requirements taken from the codes adopted by Campbell

More information

Inspecting the Means of Egress Course

Inspecting the Means of Egress Course Inspecting the Means of Egress Course Including Stairways, Ramps, Exterior Egress Balconies, Hallways, Doors, and Emergency Escape and Rescue Openings in Homes International Association of Certified Home

More information

2003 INTERNATIONAL BUILDING CODE 521

2003 INTERNATIONAL BUILDING CODE 521 For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kpa. a, b, c, d, e, f FIGURE 2404(9) MAXIMUM ALLOWABLE LOAD FOR VERTICAL AND SLOPED RECTANGULAR GLASS SUPPORTED ON ALL EDGES NOTES: a. In each

More information

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL) 01/25/08 STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL) City of Austin International Residential Code: 500 Fourth Avenue NE R314.1 Width. Stairways shall not be less than 36 in clear width at all points

More information

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO EGRESS AZMIR SULTANA NICOLAS CHAMORRO MIMU SAKUMA EDWIN VEGA DEFINITIONS NC ACCESSIBLE MEANS OF EGRESS. A continuous and unobstructed way of egress travel from any accessible point in a building or facility

More information

CITY OF OCEANSIDE. Single Family Dwelling Stairways/Guards. Informational Bulletin

CITY OF OCEANSIDE. Single Family Dwelling Stairways/Guards. Informational Bulletin Single Family Dwelling Stairways/Guards Informational Bulletin Width Stairways shall not be less than 36 inches wide. The handrail may enter a maximum of 4 1/2 inches into this dimension. (2016 CRC R311.7.1

More information

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept. Residential Plan Check Addendum Page 2 of 5 Building Permit # Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept. 5 th,

More information

HOW TO USE THIS GUIDE:

HOW TO USE THIS GUIDE: HOW TO USE THIS GUIDE: DEPARTMENT OF COMMUNITY DEVELOPMENT Kristal Bachman - Administrator HELPFUL BUILDING GUIDELINES DETACHED GARAGE This guide has been designed to assist the do-it-yourselfer to create

More information

CHAPTER 24 GLASS AND GLAZING

CHAPTER 24 GLASS AND GLAZING CHAPTER 24 GLASS AND GLAZING SECTION 2401 GENERAL 2401.1 Scope. The provisions of this chapter shall govern the materials, design, construction, and quality of glass, lighttransmitting ceramic and light-transmitting

More information

2003 International Residential Building Code

2003 International Residential Building Code 2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

Visual Interpretation Of The

Visual Interpretation Of The Visual Interpretation Of The N T E R N A T I O N A L E S I D E N T I A L O D E 2006 IRC NEW JERSEY EDITION RESIDENTIAL BUILDING CODE SECTION R314 STAIRWAYS R314.1 Width. Stairways shall not be less than

More information

Adult Family Home Inspections

Adult Family Home Inspections Adult Family Home Inspections 1 Color Key Building Inspectors Residential Care Services Licensors 2 Definitions An Adult Family Home (AFH) A residential home in which a person or an entity is licensed

More information

City of Santa Monica Building and Safety Division

City of Santa Monica Building and Safety Division This is to be used as a general checklist; it is not inclusive of all code requirements and inspection criteria. GENERAL REQUIREMENTS Approved plans and inspection card to be on job site. (CBC 106.4.2

More information

Comparison of the IRC and IEBC in Relation to One- and Two- Family Dwellings and Townhouses

Comparison of the IRC and IEBC in Relation to One- and Two- Family Dwellings and Townhouses 2015 International Residential Code: Provisions related to existing structures R101.2 Scope. The provisions of the International Residential Code for One- and Two-family Dwellings shall apply to the construction,

More information

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) , BUILDING PERMIT REQUIREMENTS FOR BASEMENT REMODELING 1. Provide two copies of a detailed floor plan and elevation drawing, see sample drawings on page 9 and 10. Include materials, sizes, supports, heating,

More information

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017)

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017) LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017) It is the responsibility of the permit applicant to notify the building inspector when the work is ready for inspection. To request an

More information

* RESIDENTIAL PLAN REVIEW *

* RESIDENTIAL PLAN REVIEW * CITY OF DES MOINES, IOWA COMMUNITY DEVELOPMENT DEPARTMENT PERMIT AND DEVELOPMENT CENTER 602 Robert D. Ray Drive DES MOINES, IOWA 50309 Phone: 515.283.4200 Facsimile: 515.283.4270 Based on the scope of

More information

RESIDENTIAL REMODELING AND BASEMENT FINISH

RESIDENTIAL REMODELING AND BASEMENT FINISH RESIDENTIAL REMODELING AND BASEMENT FINISH CITY OF HUTCHINSON BUILDING DEPARTMENT 111 Hassan Street SE, Hutchinson, MN 55350 Phone: (320) 234-4216 Web Site www.ci.hutchinson.mn.us/building.htm This handout

More information

2012 IRC Sections R303 R310 Building Planning II

2012 IRC Sections R303 R310 Building Planning II Study Session 3 2012 IRC Sections R303 R310 Building Planning II OBJECTIVE: To develop an understanding of the health and safety criteria of the code, including light and ventilation; minimum room areas

More information

General Building Information

General Building Information Software Module s Description Page 1 General Building Information BUILDING AREA AND HEIGHT - This module designed to determine the height and area of buildings on the basis of occupancy group classification

More information

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:

More information

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax:

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax: Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL 60148 Tel: 630-620-5750 Fax: 630-629-2374 Accessory Structures: Decks, Terraces, Gazebos, Porches,

More information

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code.

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code. ORDINANCE NO. 7222 AN ORDINANCE AMENDING CHAPTER 8 OF THE CODE OF ORDINANCES, REGULATING BUILDINGS WITHIN THE CORPORATE LIMITS OF THE CITY OF MANHATTAN, KANSAS; INCORPORATING BY REFERENCE THE INTERNATIONAL

More information

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section ) 8-1200. International Residential Code. ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section 6-9-40) NOTE-This article

More information

2006 INTERNATIONAL RESIDENTIAL CODE PLAN ATTACHMENT

2006 INTERNATIONAL RESIDENTIAL CODE PLAN ATTACHMENT City of Bullhead City Development Services/Public Works Residential Permit Submittal Requirements 2006 INTERNATIONAL RESIDENTIAL CODE PLAN ATTACHMENT Contact Information: Building Division (928) 763-0124

More information

2015 BUILDING CODES APPENDIX Q TINY HOUSES. Routt County Regional Building Department

2015 BUILDING CODES APPENDIX Q TINY HOUSES. Routt County Regional Building Department 2015 BUILDING CODES APPENDIX Q TINY HOUSES Routt County Regional Building Department Overview Building Permitting Flow Chart Tiny Houses Appendix Q Definitions Size and Space Requirements Stairs/Ladder/Lofts/Guards

More information

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches and shall be sized to carry the applicable roof and

More information

Data Accuracy. Below Ground Finished* Square Footage: Measured below ground level as it appears from the front view of the building.

Data Accuracy. Below Ground Finished* Square Footage: Measured below ground level as it appears from the front view of the building. Data Accuracy Why it matters You are representing your clients. Make sure you know how big the house is. Some people figure things in Price Per Square Foot Helps agents do accurate CMA s Helps with appraisals

More information

Doors, Windows, Stairs & Fireplaces Doors Doors Outdoor Entry Outdoor Entry Doors Doors Outdoor Entry Outdoor Entry

Doors, Windows, Stairs & Fireplaces Doors Doors Outdoor Entry Outdoor Entry Doors Doors Outdoor Entry Outdoor Entry Doors, Windows, Stairs & Fireplaces Doors Outdoor Entry 36 minimum entry Main/guest entrance open to social area Easy use lever handles Doors Outdoor Entry Weather resistant surface Solid wood or foam

More information

Village of Glen Ellyn Basement Remodeling Project Guidelines

Village of Glen Ellyn Basement Remodeling Project Guidelines Village of Glen Ellyn Basement Remodeling Project Guidelines Existing unfinished basement space is often remodeled to create more habitable (living, sleeping, eating, dining) space in a home. Building

More information

Municipal Code of Chicago CHAPTER EXIT REQUIREMENTS

Municipal Code of Chicago CHAPTER EXIT REQUIREMENTS Municipal Code of Chicago CHAPTER 13-160 EXIT REQUIREMENTS 13-160-010 General provisions. 13-160-020 Definitions. 13-160-030 Exit types - Requirements. 13-160-040 Exit types - Above or below grade. 13-160-050

More information

Single Family Dwelling Documents Preparation and Plan Review Guidelines California Residential Code (CRC).

Single Family Dwelling Documents Preparation and Plan Review Guidelines California Residential Code (CRC). Single Family Dwelling Documents Preparation and Plan Review Guidelines- 2010 California Residential Code (CRC). Intended to assist designers prepare adequate building permit submittals to local jurisdictions.

More information

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) PERMIT SUBMITTAL CHECKLIST: Signed completed Building Permit application form. Two (2) Copies of a Certificate of Survey. Draw to scale the

More information

Milgard Windows & Doors. Training Module Building Codes and Ratings

Milgard Windows & Doors. Training Module Building Codes and Ratings Milgard Windows & Doors Training Module Building Codes and Ratings UBC-Uniform Building Code Specific requirements for the use of safety glass, egress, and handicap accessibility. Please be aware that

More information

EGRESS WINDOWS st Ave. NE East Bethel, MN Phone: (763) Fax: (763)

EGRESS WINDOWS st Ave. NE East Bethel, MN Phone: (763) Fax: (763) 2241 221 st Ave. NE East Bethel, MN 55011 Phone: (763) 367-7844 Fax: (763) 434-9578 EGRESS WINDOWS The 2007 Minnesota State Building Code adopts the 2006 International Residential Code (2006 IRC). All

More information

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS Florida Specific Amendment Code Reference NFPA 101 Open Parking Structure. A parking structure that, at each parking level, has wall openings open to the atmosphere, for an area of not less than 1.4 ft2

More information

The permit holder is ultimately responsible for compliance with all aspects of the building code.

The permit holder is ultimately responsible for compliance with all aspects of the building code. Summary of Residential Code Requirements Building Safety Room 210 City Hall Duluth MN 55802 Ph 218/730-5300 Fax 730-5901 http://www.duluthmn.gov/building_safety/permits.cfm The first step in beginning

More information

Advanced Ventilation for Residential applications FBC Res 2010.

Advanced Ventilation for Residential applications FBC Res 2010. Advanced Ventilation for Residential applications FBC Res 2010. Course Description Review of the Residential Ventilation requirements in the Florida Building Code, Residential 2010. I. Introduction Dean

More information

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code Albemarle County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential decks only. Framing requirements are limited to single

More information

INTERIOR ENVIRONMENT

INTERIOR ENVIRONMENT CHAPTER 12 INTERIOR ENVIRONMENT > SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,

More information

CTC MEETING #25 CHILD WINDOW SAFETY REPORT

CTC MEETING #25 CHILD WINDOW SAFETY REPORT CTC MEETING #25 CHILD WINDOW SAFETY REPORT The Child Window Safety SG has not met following the 2012 Final Action Hearing. Group B activities did not necessitate SG meetings as the activity will be limited

More information

Floor Plan. *The floor plan represents a section view of a residence which has had an imaginary cut made approximately 4 feet above the floor line.

Floor Plan. *The floor plan represents a section view of a residence which has had an imaginary cut made approximately 4 feet above the floor line. Floor Plan Symbols Floor Plan *The floor plan represents a section view of a residence which has had an imaginary cut made approximately 4 feet above the floor line. *Residential floor plans are generally

More information

Building Department Informational Handout. Residential Window Replacement Requirements

Building Department Informational Handout. Residential Window Replacement Requirements City of Sonoma Building Department Informational Handout Residential Window Replacement Requirements Handout No: 28 Revised: 6/8/18 These requirements apply to the replacement of existing windows in residential

More information

2012 Code Update Training

2012 Code Update Training 2012 Code Update Training VIRGINIA RESIDENTIAL CODE Jack A. Proctor Virginia Building Code Academy Department of Housing and Community Development R202 Definitions BASEMENT R202 Definitions Story Above

More information

-=== Building Safety Departnlent 'Neil Avenue, Room 202 Cheyenne, WY Phone: (307) Fax: (307) RAMPS

-=== Building Safety Departnlent 'Neil Avenue, Room 202 Cheyenne, WY Phone: (307) Fax: (307) RAMPS Building Safety Departnlent 2101 0 'Neil Avenue, Room 202 Cheyenne, WY 82001 Phone: (307) 637-6265 Fax: (307) 637-6366 A COMMUNITY -=== II January 24,2017 OF CHOICE RAMPS This handout was prepared in an

More information

Plan Review Checklist-2015 International Residential Code

Plan Review Checklist-2015 International Residential Code Plan Review Checklist-2015 International Residential Code 1. CONSTRUCTION DOCUMENTS & COMPLIANCE TO APPROVED PLANS : IRC Section R106. (1) Approved site plans shall be attached to the approved building

More information

Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting and

Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting and BCAC MOE Work Group Summary with Files Revised 11-20-2017 with meeting notes Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting ITEM Topic SECTION Notes

More information

Work Group Item Stairways serving an occupant load of less than 50 shall have a width of not less than 36 inches (914 mm).

Work Group Item Stairways serving an occupant load of less than 50 shall have a width of not less than 36 inches (914 mm). IBC-12/13 1009.1, 1009.4, 1009.7.2, 1009.7.4, 1009.8, 1009.10, 1009.15 (IFC [B] 1009.1, 1009.4, 1009.7.2, 1009.7.4, 1009.8, 1009.10, 1009.15) Proponent: S. Bajnai, Chesterfield County, VA, ICC Building

More information

Appendix GENERAL INFORMATION TECHNICAL INFORMATION BUILDING CODES INDEX

Appendix GENERAL INFORMATION TECHNICAL INFORMATION BUILDING CODES INDEX Appendix GENERAL INFORMATION TECHNICAL INFORMATION BUILDING CODES INDEX Building Codes Building Codes Prior to using any railing products, it is incumbent on designers, fabricators and installers to make

More information

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

CODE COMPLIANCE GUIDELINE GENERAL BUILDING CODE COMPLIANCE GUIDELINE This guideline has been prepared by The Calhoun County Building Department to assist Homebuilders, General Contractors, and Owner/Builders during the construction process. The

More information

Stairs have many potential violations this Newsletter is Part 1 of two parts.

Stairs have many potential violations this Newsletter is Part 1 of two parts. Stairs have many potential violations this Newsletter is Part 1 of two parts. Violation 1 : Risers do not meet requirements: riser heights too high/low; too much variation between riser heights; risers

More information

Standard for Bleachers, Folding and Telescopic Seating, and Grandstands

Standard for Bleachers, Folding and Telescopic Seating, and Grandstands International Code Council Standard for Bleachers, Folding and Telescopic Seating, and Grandstands ICC 300-2017 edition Public Comment Draft October 2017 The ICC Consensus Committee on Bleachers, Folding

More information

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code Shenandoah County, Virginia Typical Deck Details Based on the 2012 International Residential Code The design details in this document apply to residential decks only. Framing requirements are limited to

More information

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code Shenandoah County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential decks only. Framing requirements are limited to single

More information

Screen & 3-Season Porches

Screen & 3-Season Porches Screen & 3-Season Porches PERMIT SUBMITAL CHECKLIST : City of New Prague Building Inspections Department 118 Central Ave N New Prague, MN 56071 (952) 758-4401 Fax (952) 758-1149 Signed completed Building

More information

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and & &01 GENERAL To be developed. All of the exceptions have to be coordinated. &02 SPECIAL USE AND OCCUPANCY &02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections &02.1.1 and &02.1.2.

More information

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT SAMPLE GUIDE FOR RESIDENTIAL DECKS revised 7 16 Call before you dig! 1 800 272 1000 New Jersey One Call. Utility Mark Out. THIS GENERIC GUIDE IS NOT ALL INCLUSIVE

More information

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from

More information

Typical Finished Basement Details

Typical Finished Basement Details Albemarle County, Virginia Typical Finished Basement Details Based on the 2012 Virginia Residential Code Finished basements must be constructed in conformance with these details. For requirements, details

More information

IRC 2015 Significant Changes

IRC 2015 Significant Changes IRC 2015 Significant Changes Building Planning - Chapter 3 Sec 301.2 Wind Design Criteria Ultimate design wind speed values replace basic values for 3-sec gust wind speeds in Section R301.2.1. A wind speed

More information

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO: COUNTY OF KAUAI BUILDING DIVISION, DEPARTMENT OF PUBLIC WORKS 4444 RICE STREET, SUITE 175, LIHUE, HAWAII 96766 Telephone: (808) 241-6655 Fax Number: (808) 241-6806 BUILDING CODE COMMERCIAL CHECKLIST APPLICATION

More information

By James Tente, MCP, CBO,CFM

By James Tente, MCP, CBO,CFM Significant Changes (proposed) December 20, 2018 By James Tente, MCP, CBO,CFM jtente@knoxvilletn.gov The goal of these presentations is to identify and discuss the building code changes and the impacts

More information

RESIDENTIAL BUILDING CODE HANDOUT REFERENCES: 2015 Michigan Residential Code

RESIDENTIAL BUILDING CODE HANDOUT REFERENCES: 2015 Michigan Residential Code CHEBOYGAN COUNTY DEPARTMENT OF BUILDING SAFETY 870 South Main Street P.O. Box 70 Cheboygan, Michigan 49721 Phone: (231) 627-8813 Fax: (231) 627-8454 www.cheboygancounty.net RESIDENTIAL BUILDING CODE HANDOUT

More information

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507) Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed

More information

Introduction 2 The Guidance Existing Buildings Technical Specifications Materials and Workmanship Interpretation. Part K : The Requirement 3

Introduction 2 The Guidance Existing Buildings Technical Specifications Materials and Workmanship Interpretation. Part K : The Requirement 3 Contents Page Introduction 2 The Guidance Existing Buildings Technical Specifications Materials and Workmanship Interpretation Part K : The Requirement 3 Section 1 STAIRWAYS, LADDERS AND RAMPS 4 Introduction

More information

Residential Deck Guide

Residential Deck Guide Residential Deck Guide The text and illustrations included in this guide represent opinions of the Borough of Mechanicsburg Codes and Zoning Department. This guide is for educational and information purposes

More information

R vertical and horizontal.

R vertical and horizontal. CITY OF WENTZVILLE RESIDENTIAL CODE PLAN REVIEW CHECK LIST Items indicated with an X are to be addressed by incorporation into revised plans. A checkmark indicates O.K. Date: Lot # Subdivision: Address:

More information

BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS

BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS Permit Required Any owner or authorized agent who intends to construct, enlarge,

More information

Width (2012 IRC SectionR ) Exception: The width of spiral stairways shall be in accordance with the section for spiral stairways.

Width (2012 IRC SectionR ) Exception: The width of spiral stairways shall be in accordance with the section for spiral stairways. City of Republic Community Development Department Stairways Width (2012 IRC SectionR311.7.1) REVISION DATE: JANUARY 2017 Stairways shall not be less than 36 inches in clear width at all points above the

More information

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST This list is provided as a guide to help you understand the information that must be contained on the construction drawings. This list is not all-inclusive of all building codes but is used as a general

More information

Subchapter XI I nstallation of M anufactured Homes SPS Installation standards.

Subchapter XI I nstallation of M anufactured Homes SPS Installation standards. 19 SAFETY AND PROFESSIONAL SERVICES SPS 321.02 Chapter SPS 321 CONSTRUCTION STANDARDS Subchapter I Scope SPS 321.01 Scope. Subchapter II SPS 321.02 SPS 321.03 SPS 321.035 SPS 321.04 SPS 321.042 SPS 321.045

More information

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS November 2018 Contents 1. Introduction... 1 2. Ontario Building Code and Second Dwelling Units... 1 3. How Do I Make My Secondary Dwelling Unit

More information

MEANS OF EGRESS CHAPTER 10

MEANS OF EGRESS CHAPTER 10 CHAPTER 10 MEANS OF EGRESS SECTION 1001 ADMINISTRATION 1001.1 General. Buildings or portions thereof shall be provided with a means of egress system as required by this chapter. The provisions of this

More information

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS Please note: This construction plan component list is to be used as a guide to assist you with your project. There may be elements unique to your project not

More information

Pulaski County, Virginia

Pulaski County, Virginia Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Foundation and Floor... 3

More information

Americans with Disabilities Act Accessibility Survey

Americans with Disabilities Act Accessibility Survey Americans with Disabilities Act Accessibility Survey Self-Evaluation and Transition Plan Sarpy County Impound Facility 14242 S. 156th St. Springfield, Nebraska 68159 Prepared by Sarpy County Facilities

More information

RESIDENTIAL BASEMENT ALTERATIONS GUIDE

RESIDENTIAL BASEMENT ALTERATIONS GUIDE RESIDENTIAL BASEMENT ALTERATIONS GUIDE THIS IS A GUIDE ONLY! FOR DETAILED INFORMATION, CONTACT THE BUILDING INSPECTOR OR TOWNSHIP AS ADDITIONAL REQUIREMENTS MAY PERTAIN TO YOUR PROJECT. November 2018 WHITEHALL

More information

INTERNATIONAL CODE INTERPRETATIONS

INTERNATIONAL CODE INTERPRETATIONS 2012 INTERNATIONAL CODE INTERPRETATIONS PREFACE The 2012 International Codes promulgated by the International Code Council (ICC ) comprise a comprehensive set of model regulations for the construction

More information

SUMMARY OF RESIDENTIAL CODE GENERAL PROVISIONS 2004 Florida Building Code

SUMMARY OF RESIDENTIAL CODE GENERAL PROVISIONS 2004 Florida Building Code SUMMARY OF RESIDENTIAL CODE GENERAL PROVISIONS 2004 Florida Building Code The base document for the Florida Building Code, Residential, is the 2003 International Residential Code. Many Florida-specific

More information

Residential Plan Review for New One and Two Family Dwellings

Residential Plan Review for New One and Two Family Dwellings The following is a list of items that are normally included in a set of construction drawings for one and two family dwellings. The items in bold depict those items that will be reviewed for during the

More information

Charter Township of Garfield Building Department 3848 Veterans Drive Traverse City, MI Telephone (231) FAX (231)

Charter Township of Garfield Building Department 3848 Veterans Drive Traverse City, MI Telephone (231) FAX (231) Charter Township of Garfield Building Department 3848 Veterans Drive Traverse City, MI 49684 Telephone (231) 941-1620 FAX (231) 941-5783 MICHIGAN RESIDENTIAL CODE 2006 APPLICABILITY: A PERMIT IS REQUIRED

More information

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0. Comparison Between Residential 2009 IECC with St Louis amendments, the 2015 IECC, and 2015 IECC w/ Building Codes Review Committee (BCRC) proposals: Climate Zone 4 Note: This document does not contain

More information

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES WINDOW REPLACEMENT GUIDELINES GENERAL 1. Complete and receive approval for WCA s Unit Modification Application for window replacement. 2. Obtain a permit for replacement window installation from the City

More information

CHAPTER 10 MEANS OF EGRESS

CHAPTER 10 MEANS OF EGRESS CHAPTER 10 MEANS OF EGRESS SECTION 1001 ADMINISTRATION 1001.1 General. Buildings or portions thereof shall be provided with a means of egress system as required by this chapter. The provisions of this

More information

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION Town of Hague Building Inspector: Dale Wagner Home #: 306-225-2265 Cell #: 306-241-4741 Fill all part of the permit application including the date and signature.

More information

Administrative Changes

Administrative Changes Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings

More information

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board.

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board. Schedule A Amendment to the Nova Scotia Building Code Regulations made by the Minister of Municipal Affairs under Section 4 of Chapter 46 of the Revised Statutes of Nova Scotia, 1989, the Building Code

More information