LIST OF STRUCTURAL DRAWINGS FOR THE PROPOSED G+3 CLASS IV QUARTER (TWO BEDROOM) AT PHUNTSHOLING

Size: px
Start display at page:

Download "LIST OF STRUCTURAL DRAWINGS FOR THE PROPOSED G+3 CLASS IV QUARTER (TWO BEDROOM) AT PHUNTSHOLING"

Transcription

1 STRUCTURAL DRAWINGS

2 LIST OF STRUCTURAL DRAWINGS FOR THE PROPOSED G+ CLASS IV QUARTER (TWO EDROOM) AT PHUNTSHOLING DRG. NO. DRAWING TITLE DATE OF ISSUE STR/00 STR/00 STR/0 STR/0 STR/0 STR/04 STR/05 STR/06 STR/07 STR/09 STR/0 STR/ STR/ STR/ STR/5 STR/6 STR/7 STR/8 STR/0 STR/ STR/ STR/ STR/4 STR/5 STR/6 STR/7 STR/9 STR/0 STR/ STR/ List of Structural Drawings for G+ Class IV (Two edroom) uilding, Phuntsholing General Notes on Structural Drawings General Notes on Structural Drawings Footing Layout Plan Column Layout Plan Footing & Wall Foundation Details Column Details Typical Splice location and details in column Typical Splice location and splices in beam eam - Column Junction Details Plinth eam Layout plan Plinth eam Details First Floor eam layout plan. First Floor eam Details Second Floor eam layout plan. Second Floor eam Details Third Floor eam layout plan. Third Floor eam Details Roof eam Layout Plan Roof eam Details Lintel and Details. Vertical reinforcement in project wall and lintel anchorage. Cornice Details. Slab Layout Plan Slab ottom reinforcement Plan Slab Top reinforcement Plan STR/08 Slab Section Details Staircase Layout Plan & Details Main Roof Truss Layout plan Purlin Layout Plan Truss Elevation Truss Member Schedule Truss Connection Details Truss Connection Details Prop Details Kitchen Slab Details STR/4 STR/9 STR/8 STR/

3 A. GENERAL. READ THIS DRAWINGS IN CONJUNCTION WITH ARCHITECTS' AND OTHER ENGINEERS' DRAWINGS AND SPECIFICATIONS, AND SUCH OTHER WRITTEN INSTRUCTIONS AS MAY E ISSUED.. ALL DIMENSIONS ARE IN MILIMETRE UNLESS STATED OTHERWISE.. DIMENSIONS SHALL NOT E SCALED FROM THE DRAWINGS. 4. DESIGN CONFORMS TO: IS456:000 CODE OF PRACTICE FOR PLAIN AND REINFORCED CONCRETE IS46:99 EARTHQUAKE RESISTANT DESIGN AND CONSTRUCTION OF UILDINGS I90:99 DUCTILE DETAILING OF REINFORCED CONCRETE STRUCTURES SUJECTED TO SEISMIC FORCES IS 875 : 987( Part to ) CODE OF PRACTICE FOR DESIGN LOADS( OTHER THAN EARTHQUAKE) FOR UILDINGS AND STRUCTURES. IS 89 (Part ) : 00 CRITERIA FOR EARTHQUAKE RESISTANT DESIGN OF STRUCTURES. 5. VERIFY ALL SETTING OUT DIMENSIONS WITH THE ENGINEER/ARCHITECT. VERIFY LOCATION AND DIMENSIONS OF CHASES, INSERTS, OPENINGS, WASHES, DRIPS, DEPRESSIONS, AND OTHER PROJECT REQUIREMENTS NOT SHOWN ON THE STRUCTURAL DRAWINGS. 6. IF IN DOUT, ASK. 7. REFER ANY DISCREPANCY TO ENGINEER/ARCHITECT EFORE PROCEEDING WITH THE WORK. 8. ALL CONSTRUCTION MATERIALS AND WORKMANSHIP SHALL COMPLY WITH THE SPECIFICATIONS FOR UILDING AND ROAD WORKS TOGETHER WITH THE REQUIREMENTS OF ALL RELEVANT CODES OF PRACTICE REFERRED TO HEREIN AND THE REQUIREMENTS OF ALL STATUTORY AUTHORITIES. 9. CHECK ALL DIMENSIONS EFORE STARTING WORK. 0. ALWAYS REFER ADDITIONAL NOTES PROVIDED IN THE DRAWINGS.. UNLESS OTHERWISE INDICATED, DETAILS SHOWN ARE TO E CONSIDERED TYPICAL FOR SIMILAR CONDITIONS.. NO FRAMING OR STRUCTURAL MEMERS ARE TO E MODIFIED, NOTCHED, OR CUT WITHOUT THE APPROVAL OF THE ENGINEER.. THE OWNNER SHALL FAMILIARIZE THEMSELVES WITH THE DRAWINGS. ANY DISCREPANCIES SHALL E ROUGHT TO THE ATTENTION OF THE ENGINEER EFORE PROCEEDING WITH THE AFFECTED WORK. ANY VARIATIONS OR SUSTITUTIONS OF MATERIALS OR DETAILS FROM THOSE INDICATED ON THE DRAWINGS MAY ONLY E MADE WiTH PRIOR APPROVAL OF THE ENGINEER.. FOUNDATION. FOOTINGS ARE DESIGNED FOR AN ALLOWALE EARING CAPACITY OF 50KPA. VERIFY THE SOIL STRENGTH AND OTAIN APPROVAL FROM THE ENGINEER EFORE PLACING CONCRETE.. FOUNDATION SHALL EAR ON UNDISTURED NATURAL MATERIAL OR PROPERLY PLACED AND COMPACTED CONTROLLED STRUCTURAL FILL HAVING A MINIMUM EARING CAPACITY OF 50 KPA.. CONTROLLED STRUCTURAL FILL SHALL CONSIST OF CLEAN GRANULAR MATERIAL FREE OF ORGANIC OR OTHER DELETERIOUS MATTER AND CONFORM TO THE REQUIREMENTS OF STANDARDS AND QUALITY CONTROL AUTHORITY. 4. MASONRY WALLS IN THE FORM OF RANDOM RULE MASONRY SHALL E PROVIDED ELOW THE EXTERIOR AS WELL AS INTERIOR PLINTH EAM. 5. FOOTINGS ARE DESIGNED CONSIDERING THE MINIMUM DEPTH OF 500MM ELOW THE ORIGINAL GROUND LEVEL. NOTIFY ENGINEER IF THE DEPTH OF FOOTINGS REQUIRED TO E PROVIDED VARIES FROM THE DEPTH SPECIFIED AOVE. 6. ALL EXCAVATION SHALL E DRY EFORE PLACING ANY CONCRETE. 7. IF SEEPAGE IS ENCOUNTERED DURING FOUNDATION EXCAVATION, PUMP OUT WATER EFORE PLACING CONCRETE. 8. THE FOUNDATIONS UNDER THE CONCRETE ASE SLA SHALL E COMPACTED THROUGHLY AND A MINIMUM 00MM LAYER OF COURSE AGGREGATE SHALL E PLACED OVER THE COMPACTED EARTH AND SEALED WITH 75MM THICK LAYER OF LINDING CONCRETE. 9. ACKFILLING AGAINST UILDING FOUNDATION WALLS SHALL E DONE ONLY AFTER WALLS ARE RACED TO PREVENT MOVEMENT. 0. CARE SHALL E TAKEN NOT TO OVERSTRESS ANY ADJACENT RETAINING WALLS AND STRUCTURES DURING ACKFILLING AROUND FOUNDATIONS. C. LOADING. THIS STRUCTURE HAS EEN DESIGNED FOR THE FOLLOWING NOMINAL LOADS:. DEAD LOADS: UNIT WEIGHT OF WALL 9.6 KN/M UNIT WEIGHT OF RCC 5 KN/M UNIT WEIGHT OF PCC 4 KN/M. SUPERIMPOSED LOADS(LIVE LOADS): LIVE LOAD FOR FLOORS.0 N/MM LIVE LOAD FOR STAIRCASE.0 N/MM LIVE LOAD FOR ROOF 0.75 N/MM (not accessible). WIND LOAD: ASIC WIND SPEED (ASSUMED) 45 M/S UILDING CLASS TERRAIN CATEGORY III.4 EARTHQUAKE DESIGN DATA SEISMIC ZONE V ASIC SEISMIC FORCE RESISTING SYSTEM SPECIAL MOMENT RESISTING FRAME. MAINTAIN STRUCTURE IN STALE CONDITION DURING CONSTRUCTION.. DO NOT PLACE OR STORE UILDING MATERIALS ON CONCRETE MEMERS WITHOUT ENGINEER'S APPROVAL. D. CONCRETE. CONCRETE QUALITY SHALL COMPLY WITH IS456:000. PROJECT ASSESSMENT OF CONCRETE STRENGTH IS REQUIRED.. GRADE OF CONCRETE IS M0(:.5:) FOR ALL RCC WORKS. 4. FOR THE AOVE GRADE TO E ACHIEVED, MAXIMUM FREE WATER-CEMENT RATIO SHALL E 0.55, MINIMUM CEMENT CONTENT SHALL E KG/M AND MAXIMUM AMOUNT OF WATER SHALL E 65L FOR KG/M OF CEMENT. 5. ONLY POTALE WATER SHALL E USED FOR MIXING AND CURING, AND SHALL COMPLY TO THE REQUIREMENTS OF IS456: MECHANICALLY VIRATE CONCRETE IN THE FORM TO GIVE MAXIMUM COMPACTION WITHOUT SEGREGATION OF THE CONCRETE. 7. CURE CONCRETE AS REQUIRED Y THE CLASUE.5 OF IS456:000 AND WORK SPECIFICATIONS. 8. IN THE DRAWINGS THE EAM SIZES ARE DESIGNATED WIDTH X DEPTH (INCLUDES SLA THICKNESS IF ANY). 9. CONCRETE SIZES AS DRAWN ARE MINIMUM AND DO NOT INCLUDE APPLIED FINISHES. 0. DO NOT MAKE UNSPECIFIED HOLES OR CHASES WITHOUT ENGINEER'S PRIOR APPROVAL.. DO NOT PLACE CONDUITS, PIPES AND THE LIKE WITHIN COVER CONCRETE.. AGGREGATES SHALL COMPLY WITH CLAUSE 5. OF IS456:000. NOMINAL SIZE OF COARSE AGGREGATES SHALL E 0MM.. THE CHARACTERISTIC STRENGTH OF CONCRETE AT 8 DAYS SHALL E 0MPA. THE CONCRETE SHALL E ASSESSED AS PER THE ACCEPTANCE CRITERIA OUTLINED IN CLAUSE 6 OF IS456:000 OR ANY OTHER STATUTORY AUTHORITIES. 4. ALL FORMWORKS FOR EAMS AND SLAS ARE TO E REMOVED EFORE CONSTRUCTION OF WALLS OR OTHER PERMANENT LOADINGS. ALL FORMWORK AND ITS REMOVAL MUST E IN ACCORDANCE TO IS456: ALL FLOOR SLAS ARE REINFORCED CONCRETE SLAS.. COMPACTION OF FOUNDATION SHALL E APPROVED Y ENGINEER PRIOR TO PLACEMENT OF CONCRETE.

4 E. REINFORCEMENT. GRADE OF STEEL USED FOR RCC WORKS SHALL E FE500(TMT).. AR NOTATION GIVES THE FOLLOWING INFORMATION IN THIS ORDER:NUMER OF ARS; AR SIZE(MM); SPACING (MM, IF REQUIRED).. REINFORCEMENT IS REPRESENTED DIAGRAMATICALLY AND NOT NECESSARILY IN TRUE PROJECTION. 4. LAP REINFORCEMENT ONLY AT LOCATIONS SHOWN IN THE DRAWINGS. LAP LENGTH SHALL COMPLY WITH IS456:000. LAP SPLICES SHALL NOT E LESS THAN THE DEVELOPMENT LENGTH IN TENSION( GENERALLY 47X Ø). 5. REINFORCEMENT SHALL NOT E CUT, ENT OR HEATED ON SITE WITHOUT ENGINEER'S PRIOR APPROVAL. 6. THE DEVIATION OF REINFORCEMENT FROM ITS SPECIFIED POSITION SHALL NOT EXCEED THE FOLLOWING(MM): 6.) TOLERENCE FOR COVER -0,+0 MM. WHERE A NEGATIVE VALUE INDICATES A DECREASE IN SPECIFIED COVER, AND POSITIVE VALUE INDICATES AN INCREASE IN COVER. 6.) TOLERENCES ON PLACING OF REINFORCEMENT: I) FOR SLAS AND STAIRCASE -0,+0MM. II) FOR EAMS COLUMNS AND FOUNDATION -5,+5 MM. 7. SPACERS AND SUPPORTS SHALL E LOCATED AT CENTRES CLOSE ENOUGH(PREFERALY NOT EXCEEDING 750MM C/C FOR COLUMN AND EAM REINFORCEMENT, AND 450MM FOR SLA REINFORCEMENT) TO PREVENT DISPLACEMENT OF REINFORCEMENT Y WORKMEN OR EQUIPMENT DURING FIXING AND SUSEQUENT CONCRETE PLACEMENT WITHIN THE TOLERENCE GIVEN IN 6 AOVE. 8. THE COVER TO THE REINFORCEMENT NEAREST TO THE CONCRETE SURFACE SHALL NOT E LESS THAN THE FOLLOWING EXCEPT WHERE SPECIFIED OTHERWISE: EAMS 0 MM COLUMNS 40 MM FLOOR SLAS AND STAIRCASE 0 MM FOUNDATION 50 MM 9. ENDING OF REINFORCEMENT IN EAMS AND COLUMNS SHALL COMPLY WITH THE REQUIREMENTS OF IS456: REINFORCEMENT SHALL E SUJECT TO LAORATORY TEST TO DETERMINE DUCTILE PROPERTY.. INSTALLATION OF REINFORCEMENT SHALL E COMPLETED AT LEAST 4 HOURS PRIOR TO SCHEDULED CONCRETE PLACEMENT. NOTIFY ENGINEER AT LEAST 48 HOURS PRIOR TO SCHEDULED CONRETE PLACEMENT, TO ALLOW TIME FOR INSPECTION. F. TIMER. ALL STRUCTURAL TIMER SHALL CONFORM TO THE IS88.( If available use the hutanese Timber Code). MOISTURE CONTENT OF THE STRUCTURAL TIMER SHALL NOT EXCEED %.. ALL STRUCTURAL TIMER SHALL HAVE A MINIMUM ALLOWALE ENDING STRESS, Fb, OF 7MPA, A MINIMUM ALLOWALE HORIZONTAL SHEAR STRESS, Fv, OF 0.6MPA, A MINIMUM MODULUS OF ELASTICITY, E, OF 9800MPA, AND MAXIMUM UNIT WEIGHT OF 5.75 KN/M. G. FORMWORK. PROPERLY RACE AND SHORE FORMWORK TO MAINTAIN ALIGNMENT AND TOLERANCE IN ACCORDANCE WITH IS456:000.. FORMWORK SHALL COMPLY WITH CLAUSE OF IS456:000.. STRIPPING OF FORMWORK SHALL COMPLY WITH CLAUSE. OF IS456:000.

5 F F F F F F F F F F F F F F F F F F NOTES:. GROUND LEVEL REFERS TO THE LEVELLED GROUND AFTER HAVING REMOVED ALL THE TOP ORGANIC SOIL.. THE MINIMUM DEPTH OF FOUNDATION SHALL E 500MM FROM THE GROUND LEVEL.. ACK FILL SHALL E FULLY COMPACTED EFORE PLACING GROUND FLOOR CONCRETE. 4. PROPER ANCHORAGE OF EAM ARS IN EXTERIOR COLUMN SHALL E PROVIDED AS DETAILED IN DRAWING NO. STR/ IN ORDER TO ACHIEVE PROPER ANCHORAGE OF EAM ARS INTO EXTERIOR COLUMNS, ALL EXTERIOR COLUMN SHALL E CAST ONLY UP TO /4 OF THEIR HEIGHT EFORE LAYING EAM REINFORCEMENT IN UPPER FLOOR. REFERENCE:. REFER DRG. NO. STR/0 FOR COLUMN LAYOUT PLAN. REFER DRG. NO. STR/0 FOR FOOTING & WALL FOUNDATION DETAILS. REFER DRG. NO. STR/04 FOR COLUMN DETAILS 5. REFER DRG. NO. STR/05 FOR COLUMN SPLICE DETAILS. 6. REFER DRG. NO. STR/06 FOR EAM SPLICE DETAILS 7. REFER DRG. NO. STR/07 FOR EAM- COLUMN JUNCTION DETAILS.

6 C C C C C C 50 C C C C C C 55 C C C C C C NOTES:. GROUND LEVEL REFERS TO THE LEVELLED GROUND AFTER HAVING REMOVED ALL THE TOP ORGANIC SOIL.. THE MINIMUM DEPTH OF FOUNDATION SHALL E 500MM FROM THE GROUND LEVEL.. ACK FILL SHALL E FULLY COMPACTED EFORE PLACING GROUND FLOOR CONCRETE. 4. PROPER ANCHORAGE OF EAM ARS IN EXTERIOR COLUMN SHALL E PROVIDED AS DETAILED IN DRAWING NO. STR/ IN ORDER TO ACHIEVE PROPER ANCHORAGE OF EAM ARS INTO EXTERIOR COLUMNS, ALL EXTERIOR COLUMN SHALL E CAST ONLY UP TO /4 OF THEIR HEIGHT EFORE LAYING EAM REINFORCEMENT IN UPPER FLOOR. REFERENCE:. REFER DRG. NO. STR/0 FOR COLUMN LAYOUT PLAN. REFER DRG. NO. STR/0 FOR FOOTING & WALL FOUNDATION DETAILS. REFER DRG. NO. STR/04 FOR COLUMN DETAILS 5. REFER DRG. NO. STR/05 FOR COLUMN SPLICE DETAILS. 6. REFER DRG. NO. STR/06 FOR EAM SPLICE DETAILS 7. REFER DRG. NO. STR/07 FOR EAM- COLUMN JUNCTION DETAILS.

7 L EAM IN THE ORTHOGONAL DIRECTION COLUMN ARS (REFER DETAILS) GROUND FLOOR EAM (Refer Details) GROUND FLOOR LEVEL RL M RICK WALL PLINTH EAM REFER ARCHITECTURAL DRAWING RL ± M A A C L OF COLUMN/ FOOTING 75mm side cover 500 MIN 50 PROVIDE EXTRA COVER TO COLUMN ELOW GROUND TOP REAR (SEE TALE ELOW ) RRM IN CM (:4) 75 MM THICK PCC(::6) 50 MM THICK STONE SOLING 800 C OF COLUMN/FOOTING L TYPICAL FOOTING PLAN 50mm MIN L dt = 57Ø OF AR TYPICAL FOOTING ELEVATION (SECTION A-A) RL M D 75MM PROJECTION 00 MM CONCRETE(::4), 40mm agg. 50 MM STONE SOLING OTTOM REAR (SEE TALE ELOW ) FOUNDATION FOR INTERNAL WALL ELOW ASEMENT/PLINTH EAM AND PARTITION WALL NOTES: SAME WALL FOUNDATION DETAILS SHALL E ADOPTED FOR ALL WALLS.. FOOTING MARK F F F L FOOTING SIZE 000 D FOOTING SCHEDULE OTTOM REAR IN L-DIRECTION Ø@80 c/c Ø@50 c/c OTTOM REAR IN -DIRECTION Ø@80 c/c Ø@50c/c TOP REAR IN OTH DIRECTION 0Ø@80 c/c 0Ø@80 c/c 450 Ø@50 c/c Ø@50c/c 0Ø@80 c/c PLINTH EAM RL ± M FOOTING & WALL FOUNDATION DETAILS RICK WALL RRM IN CM (:4) REFER ARCHITECTURAL DRAWING 75 MM THICK PCC(::6) 50 MM THICK STONE SOLING FOUNDATION FOR EXTERNAL WALL ELOW ASEMENT/PLINTH EAM NOTES: REAR SIZE Ø 6Ø 0Ø 5Ø ANCHORAGEMENT LENGTH, Ldt GROUND LEVEL REFERS TO THE LEVELLED GROUND AFTER HAVING REMOVED ALL THE TOP ORGANIC SOIL.. THE MINIMUM DEPTH OF FOUNDATION SHALL E 500MM FROM THE GROUND LEVEL. ACK FILL SHALL E FULLY COMPACTED EFORE PLACING GROUND FLOOR CONCRETE. 4. PROPER ANCHORAGE OF EAM ARS IN EXTERIOR COLUMN SHALL E PROVIDED AS DETAILED IN DRAWING NO. STR/07 5. IN ORDER TO ACHIEVE PROPER ANCHORAGE OF EAM ARS INTO EXTERIOR COLUMNS, ALL EXTERIOR COLUMN SHALL E CAST ONLY UP TO /4 OF THEIR HEIGHT EFORE LAYING EAM REINFORCEMENT IN UPPER FLOOR.

8 COLUMN SCHEDULE ROOF LEVEL Type C Size X Main ar 8-0Ø Ties (), at splices & below the plinth level 75 c/c Ties (S) 50 c/c C X 4-5Ø+4-6Ø 75 c/c 50 c/c C X 4-5Ø+4-0Ø 75 c/c 50 c/c 4-0Ø 4-5Ø 4-5Ø Special confining zone SECOND FLOOR LEVEL Special confining zone 900 S 4-0Ø ties 8Ø 4-6Ø ties 8Ø 4-0Ø ties 8Ø SPLICING Ld 50 Non splicing zone S C C C Special confining zone 900 FIRST FLOOR LEVEL 900 TYPICAL COLUMN DETAILS SHOWING TIES Special confining zone NOTES:. ALL SPLICES TO E PROVIDED NEAR THE MIDDLE OF COLUMN.. NOT MORE THAN 50% OF COLUMN ARS SHALL E SPLICED AT ONE SECTION.. SPLICING OF COLUMN ARS AT ASEMENT AND GROUND FLOOR IS NOT PERMITTED. 4. COLUMN DETAILS IS SAME UP TO ROOF LEVEL. 5. CLOSER SPACING OF TIES OF 75 MM C/C SHOULD E PROVIDED THROUGH OUT THE COLUMN SUPPORTING STAIRCASE. 6. TIES SPACING OF 75 MM C/C SHOULD E PROVIDED IN ALL COLUMNS UP TO GROUND FLOOR. 7. COLUMN SHOULD CONTINUE TILL TIE EAM SUPPORTING TRUSSES AND EAMS. 8. IN ORDER TO ACHIEVE PROPER ANCHORAGE OF EAM ARS INTO EXTERIOR COLUMNS, ALL EXTERIOR COLUMN SHALL E CAST ONLY UP TO /4 OF THEIR HEIGHT EFORE LAYOUT EAM REINFORCEMENT IN UPPER FLOORS. 9. Ld = 6 MM = MM = 50 5 MM = 450 GL 50 GROUND FLOOR LEVEL 500 Non splicing zone Special confining zone Special confining zone S GL REFERENCES:. REFER DRG. NO. STR/0& 0 FOR FOOTING & COLUMN LAYOUT PLAN.. REFER DRG. NO. STR/0 FOR FOOTING & WALL FOUNDATION DETAILS.. REFER DRG. NO. STR/07 FOR EAM- COLUMN JUNCTION DETAILS. 4. REFER DRG. NO. STR/06 FOR COLUMN SPLICE DETAILS. 5. REFER DRG. NO. STR/8 FOR STAIRCASE DETAILS. COLUMN DETAILS

9 EXTERIOR EAM-COLUMN CONNECTION (REFER DETAIL ON DWG NO. STR/07) ROOF LEVEL INTERIOR EAM-COLUMN CONNECTION (REFER DETAILS IN STR/07) 50 S Special confining zone 900 SECOND FLOOR LEVEL Special confining zone MM COVER(MIN.) r SPLICING Ld 50 Non splicing zone S TYPICAL COLUMN DETAIL END RADIUS, 4Ø Special confining zone 900 FIRST FLOOR LEVEL Special confining zone 900 Rebar size 0Ø Ø Development length,ld end Radius, r 4Ø Non splicing zone Special confining zone S 6Ø 0Ø 5Ø GROUND FLOOR LEVEL GL GL NOTES: 500 Special confining zone. ALL SPLICES TO E PROVIDED NEAR THE MIDDLE OF COLUMN.. NOT MORE THAN 50% OF COLUMN ARS SHALL E SPLICED AT ONE SECTION.. SPLICING OF COLUMN ARS AT ASEMENT AND GROUND FLOOR IS NOT PERMITTED. 4. COLUMN DETAILS IS SAME UP TO ROOF LEVEL. 5. CLOSER SPACING OF TIES OF 75 MM C/C SHOULD E PROVIDED THROUGH OUT THE COLUMN SUPPORTING STAIRCASE. 6. TIES SPACING OF 75 MM C/C SHOULD E PROVIDED IN ALL COLUMNS UP TO GROUND FLOOR. 7. COLUMN SHOULD CONTINUE TILL TIE EAM SUPPORTING TRUSSES AND EAMS. 8. IN ORDER TO ACHIEVE PROPER ANCHORAGE OF EAM ARS INTO EXTERIOR COLUMNS, ALL EXTERIOR COLUMN SHALL E CAST ONLY UP TO /4 OF THEIR HEIGHT EFORE LAYOUT EAM REINFORCEMENT IN UPPER FLOORS. COLUMN SPLICE DETAILS

10 D L/ L Ld D 5 D Ld D D D 0Ø b Ld L/ D S/ D D Top splice, Ld D ottom splice, Ld b Ld NOTES : D D D D. SPLICING OF OTTOM EAM ARS SHAL E PROVIDED D AWAY FROM THE FACE OF THE COLUMN. SPLICING OF OF TOP EAM ARS SHALL E AT MID SPAN ( L/). NOT MORE THAN 50% OF EAM ARS SHALL E SPLICED AT ONE SECTION 4. STIRRUPS SPACING AT SPLICES SHALL E 75C/C 5. SPLICING LENGTH SHALL NOT E LESS THAN DEVELOPMENT LENGTH, Ld TYPICAL ARRANGEMENT OF STIRRUPS & SPLICES IN EAMS

11 EXTERIOR COLUMN COLUMN COLUMN REINFORCEMENTS 50MM (MAX) EAM EAM REINFORCEMENTS 50 MM (MAX) EAM SECONDARY EAM 50Ø PRIMARY EAM Ld = 50 MM FOR 0Ø = 450 MM FOR 5Ø = 950 MM FOR 6 Ø = 700 MM FOR Ø COLUMN TIES WITHIN THE JOINT PRIMARY-SECONDARY EAM JUNCTION DETAILS TYPICAL EXTERIOR EAM - COLUMN INTERIOR EAM - COLUMN CONNECTION DETAIL (SIDE VIEW) CONNECTION DETAIL ( SIDE VIEW) EAM EAM EAM COLUMN PCC EAM REINFORCEMENT COLUMN COLUMN 50 MM (MAX) 50 MM (MAX) COLUMN TIE PCC COLUMN REINFORCEMENT COLUMN TIE COLUMN REINFORCEMENT COLUMN TIE COLUMN REINFORCEMENT EAM AR ENT FOR ANCHORAGE EAM AR ENT FOR ANCHORAGE EAM STIRRUPS TYPICAL EXTERIOR EAM - COLUMN CONNECTION DETAIL (PLAN VIEW) TYPICAL INTERIOR EAM - COLUMN CONNECTION DETAIL (PLAN VIEW) EAM -COLUMN JUNCTION DETAILS

12 Extra PCC Extra PCC Extra PCC Extra PCC PLINTH EAM LAYOUT PLAN

13 A C D E 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø -6Ø -6Ø -6Ø -6Ø -6Ø F 700 S 4-Ø S S S S Ø 4-Ø 4-Ø 4-Ø L-SECTION OF PLINTH EAM ALONG GRID & (x50) A 4-6Ø 4-6Ø 4-6Ø 4-6Ø -6Ø -6Ø Ø+-6Ø -0Ø+-6Ø -0Ø+-6Ø -0Ø+-6Ø -0Ø -0Ø S 4-Ø 50 S 4-6Ø S S S Ø 4-Ø 4-Ø S Ø S Ø 55 L-SECTION OF PLINTH EAM ALONG GRID A,, C, D, E & F (x50) C L-SECTION OF PLINTH EAM ALONG GRID (x50) -Ø -Ø Ø 4-6Ø -6Ø 550 PCC 50 SECTION - Stirrups Details = S = D PCC 4-6Ø 4-Ø E 4-6Ø 4-6Ø 4-6Ø 4-6Ø -6Ø -6Ø SECTION - REFERENCES: -6Ø 4-Ø 50 SECTION - -6Ø -0Ø 4-6Ø. REFER DRG. NO. STR/08 FOR PLINTH EAM LAYOUT PLAN.. REFER DRG. NO. STR/07 FOR EAM- COLUMN JUNCTION DETAILS.. REFER DRG. NO. STR/06 FOR EAM SPLICE DETAILS. 4. REFER DRG. NO. STR/5 FOR STAIRCASE DETAILS. 50 F SECTION Ø 4-6Ø

14 Extra PCC Extra PCC 50 Extra PCC 55 FIRST FLOOR EAM LAYOUT PLAN

15 A C D E 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø -0Ø -0Ø -0Ø -0Ø -0Ø F 800 S S S S S Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø A L-SECTION OF FIRST FLOOR EAM ALONG GRID & (x) C D E 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø -0Ø -0Ø -0Ø -0Ø F 800 S S S S Ø 4-6Ø 4-6Ø 4-6Ø L-SECTION OF FIRST FLOOR EAM ALONG GRID (x) 4-5Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø -5Ø Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø -5Ø S S 800-0Ø+-6Ø -0Ø+-6Ø S S 800-0Ø+-6Ø -0Ø+-6Ø L-SECTION OF FIRST FLOOR EAM ALONG GRID A,, E & F (x) PCC PCC -0Ø -6Ø 4-0Ø -5Ø -0Ø 4-6Ø 4-6Ø -6Ø SECTION - SECTION - SECTION - SECTION L-SECTION OF FIRST FLOOR EAM ALONG GRID C & D (x) -5Ø -0Ø -6Ø REFERENCES:. REFER DRG. NO. STR/0 FOR FIRST FLOOR EAM LAYOUT PLAN.. REFER DRG. NO. STR/07 FOR EAM- COLUMN JUNCTION DETAILS.. REFER DRG. NO. STR/06 FOR EAM SPLICE DETAILS. 4. REFER DRG. NO. STR/5 FOR STAIRCASE DETAILS. Stirrups Details = S =

16 Extra PCC Extra PCC 50 Extra PCC 55 SECOND FLOOR EAM LAYOUT PLAN

17 A C D E 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø -0Ø -0Ø -0Ø -0Ø -0Ø F 800 S S S S S Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø A L-SECTION OF SECOND FLOOR EAM ALONG GRID & (x) C D E 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø 4-0Ø -0Ø -0Ø -0Ø -0Ø F 800 S S S S Ø 4-6Ø 4-6Ø 4-6Ø L-SECTION OF SECOND FLOOR EAM ALONG GRID (x) 4-5Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø -5Ø Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø+-6Ø -5Ø -5Ø S S 800-0Ø+-6Ø -0Ø+-6Ø S S 800-0Ø+-6Ø -0Ø+-6Ø L-SECTION OF SECOND FLOOR EAM ALONG GRID A,, E & F (x) PCC PCC -0Ø -6Ø 4-0Ø -5Ø -0Ø 4-6Ø 4-6Ø -6Ø SECTION - SECTION - SECTION - 4 L-SECTION OF SECOND FLOOR EAM ALONG GRID C & D (x) SECTION Ø -0Ø -6Ø REFERENCES:. REFER DRG. NO. STR/ FOR SECOND FLOOR EAM LAYOUT PLAN.. REFER DRG. NO. STR/07 FOR EAM- COLUMN JUNCTION DETAILS.. REFER DRG. NO. STR/06 FOR EAM SPLICE DETAILS. 4. REFER DRG. NO. STR/5 FOR STAIRCASE DETAILS. Stirrups Details = S =

18 Extra PCC Extra PCC 50 Extra PCC 55 THIRD FLOOR EAM LAYOUT PLAN

19 A 4-6Ø -6Ø 980 C D E 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø -6Ø -6Ø -6Ø -6Ø F 800 S S S S S Ø 4-Ø 4-Ø 4-Ø 4-Ø A 4-6Ø -6Ø 980 L-SECTION OF THIRD FLOOR EAM ALONG GRID & (x) C D E 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø -6Ø -6Ø -6Ø F 800 S S S S Ø 4-Ø 4-Ø 4-Ø L-SECTION OF THIRD FLOOR EAM ALONG GRID (x) 4-0Ø+-6Ø -0Ø+-6Ø -0Ø+-6Ø -0Ø+-6Ø -0Ø+-6Ø -0Ø -0Ø Ø+-6Ø -0Ø+-6Ø -0Ø+-6Ø -0Ø+-6Ø -0Ø -0Ø S 4-6Ø S Ø S 4-6Ø S Ø 55 4 L-SECTION OF THIRD FLOOR EAM ALONG GRID A,, E & F (x) PCC PCC -6Ø -6Ø 4-6Ø -0Ø 4-Ø 4-Ø 4-6Ø SECTION - SECTION - SECTION - SECTION L-SECTION OF THIRD FLOOR EAM ALONG GRID C & D (x) -0Ø 4-6Ø REFERENCES:. REFER DRG. NO. STR/4 FOR THIRD FLOOR EAM LAYOUT PLAN.. REFER DRG. NO. STR/07 FOR EAM- COLUMN JUNCTION DETAILS.. REFER DRG. NO. STR/06 FOR EAM SPLICE DETAILS. 4. REFER DRG. NO. STR/5 FOR STAIRCASE DETAILS. Stirrups Details = S =

20 Extra PCC Extra PCC 50 Extra PCC 55 ROOF EAM LAYOUT PLAN

21 A C D E 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø 4-6Ø -6Ø -6Ø -6Ø -6Ø -6Ø F 700 S S S S S Ø 4-Ø 4-Ø 4-Ø 4-Ø L-SECTION OF ROOF EAM ALONG GRID, & (x50) REFERENCES: 4-6Ø 4-6Ø 4-6Ø 4-6Ø -6Ø -6Ø S 4-Ø S Ø 55 PCC 50 PCC 4-6Ø 50 4-Ø SECTION - SECTION - -6Ø 4-Ø. REFER DRG. NO. STR/6 FOR ROOF EAM LAYOUT PLAN.. REFER DRG. NO. STR/07 FOR EAM- COLUMN JUNCTION DETAILS.. REFER DRG. NO. STR/06 FOR EAM SPLICE DETAILS. 4. REFER DRG. NO. STR/5 FOR STAIRCASE DETAILS. Stirrups Details = S = L-SECTION OF ROOF EAM ALONG GRID A,, C, D, E & F (x50)

22 A DOOR / WINDOW OPENING A LINTEL AND OVER OPENINGS Masonry Wall DOOR / WINDOW OPENING LINTEL AND OVER OPENINGS c c SECTION A-A -8Ø per boh -Ø 8Ø@50c/c -Ø SECTION - -Ø -Ø 8Ø@50c/c 50 -Ø -Ø 5 -Ø SECTION C-C INTERNAL NOTES :. LINTEL AND SHALL E PROVIDED FOR THE FULL LENGTH OF WALLS.. LAP LENGTH OF LINTEL AND REINFORCEMENT SHALL NOT E LESS THAN 47XØ OF AR.. LINTEL AND SHALL EXTEND FROM COLUMN TO COLUMN ENCLOSING PROJECTED WALLS 4. LINTEL AND REINFORCEMENT SHALL E PROPERLY ANCHORED TO COLUMNS. LINTEL AND DETAILS

23 0Ø AS VERTICAL REINFORCEMENT -0Ø AS VERTICAL REINFORCEMENT DETAIL A MASONRY WALL AND REINFORCEMENT 0Ø AS VERTICAL REINFORCEMENT -Ø ( OTH DIRECTIONS) 0Ø VERTICAL REINFORCEMENT -Ø DETAIL DETAIL C 450 X RCC COLUMN X VERTICAL REINFORCEMENT LINTEL AND MASONRY 450 RCC COLUMN TYPICAL LAYOUT OF VERTICAL REINFORCEMENT THROUGH PROJECTED WALLS DETAIL TYPICAL LINTEL AND DETAIL AT CORNER OVER PROJECTED EXTERNAL WALL SECTION X-X MASONRY WALL RCC COLUMN LINTEL AND REINFORCEMENT MASONRY WALL RCC COLUMN LINTEL AND REINFORCEMENT VERTICAL REINFORCEMENT -Ø X X DETAIL C RCC COLUMN LINTEL AND REINFORCEMENT DETAIL A 0Ø VERTICAL REINFORCEMENT LINTEL AND REINFORCEMENT TYPICAL LINTEL AND DETAIL AT CORNER OVER NON PROJECTED EXTERNAL WALL TYPICAL LINTEL AND DETAIL AT MIDDLE OVER NON PROJECTED EXTERNAL WALL TYPICAL LINTEL AND DETAIL AT MIDDLE OVER PROJECTED EXTERNAL WALL NOTES :. VERTICAL REINFORCEMENT SHALL E PROVIDED WITHIN WALLS WHERE WALL ARE PROJECTED OUTWARD FROM THE MAIN UILDING LINE.. VERTICAL REINFORCEMENT SHALL EXTEND FROM SECOND FLOOR SLA/EAM TO ROOF SLA/EAM.. VERTICAL REINFORCEMENT SHALL E PROPERLY ANCHORED TO FLOOR SLA/EAM AND EMEDMENT LENGTH SHALL E NOT LESS THAN 47Ø OF AR. 4. LINTEL AND SHALL CONTINUE THROUGHOUT THE LENGTH OF WALL. VERTICAL REINFORCEMENT FOR PROJECTED WALL AND LINTAL ANCHORAGE

24 MASONRY WALL SLA REINFORCEMENT -0Ø(PER OH) FIRST FLOOR LEVEL 40 CORNICE HOLDING EAM -0Ø(PER OH) ROOF EAM (REFER DETAILS) ROOF LEVEL 50 EXTRA REAR SHAPE TIMER CORNICE (REFER ARCH. DRAWINGS FOR DETAILS) -Ø -Ø COLUMN OUTSIDE FACE COLUMN INSIDE FACE FIRST LEVEL CORNICE MASONRY WALL C OF COLUMN L EXTRA REAR SHAPE C OF COLUMN L ROOF LEVEL CORNICE DETAILS MASONRY WALL COLUMN INSIDE FACE COLUMN OUTSIDE FACE EAM FACE PCC(:.5:) SLA REINFORCEMENT -0Ø(PER OH) GROUND/FIRST/SECOND FLOOR LEVEL MASONRY WALL -0Ø SLA REINFORCEMENT -0Ø(PER OH) SECOND FLOOR LEVEL 50 EXTRA REAR SHAPE NOTES & REFERENCE:. NOTIFY ENGINEERS IF CORNICE DIFFER SIGNIFICANTLY AT SITE FROM THE DETAILS GIVEN HEERIN.. REFER ARCHITECTURAL DRAWINGS FOR LOCATION 7 COVERAGE OF CORNICE. C OF COLUMN L GROUND FLOOR LEVEL CORNICE COLUMN OUTSIDE FACE C OF COLUMN L COLUMN INSIDE FACE SECOND FLOOR LEVEL CORNICE

25 Extra PCC 55 REFERENCES:. REFER DRAWING NO. STR/, STR/, STR/4 FOR SLA DETAILS.. REFER DRAWING NO. STR/5 FOR STAIRCASE DETAILS. NOTES: FLOOR SLA THICKNESS 0 MM ROOF SLA THICKNESS 00 MM NO SLA ON THE VERANDAH IN ROOF SLA

26 Y C/C C/C STAIRCASE C/C 50 X 55 X NOTES: Y FLOOR SLA THICKNESS 0 MM ROOF SLA THICKNESS 00 MM NO SLA ON THE VERANDAH IN ROOF SLA 0Ø@70 C/C REFERENCES:. REFER DRAWING NO. STR/4 FOR SLA SECTION DETAILS.. REFER DRAWING NO. STR/4 FOR TYPICAL ANCHORAGE OF SLA AR INTO EAMS.. REFER DRAWING NO. STR/5 FOR STAIRCASE DETAIL.

27 Y STAIRCASE C/C X 55 X NOTES: Y 0Ø@50 C/C REFERENCES: FLOOR SLA THICKNESS 0 MM ROOF SLA THICKNESS 00 MM NO SLA ON THE VERANDAH IN ROOF SLA. REFER DRAWING NO. STR/4 FOR SLA SECTION DETAILS.. REFER DRAWING NO. STR/4 FOR TYPICAL ANCHORAGE OF SLA AR INTO EAMS.. REFER DRAWING NO. STR/5 FOR STAIRCASE DETAIL.

28 500 (MIN) SLA EAM NOTES: C/C C/C C/C C/C C/C C/C C/C C/C TYPICAL DETAI OF ANCHORAGE OF SLA REINFORCEMENT IN EAM. FLOOR SLA THICKNESS IS 0 MM. ROOF SLA THICKNESS IS 00 MM. ADOPT SAME SECTION DETAILS FOR ALL SLAS 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C REFERENCES:. REFER DRAWING NO. STR/ & STR/ FOR TOP AND OTTOM REINFORCEMENT SECTION Y-Y. REFER DRAWING NO. STR/5 FOR STAIRCASE DETAIL. A C D E F Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@50 C/C 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C 0Ø@70 C/C SECTION X-X SLA SECTION DETAILS

29 FLOOR SLA (REFER SLA DETAILS) A 0Ø@50c/c Ø@50c/c 000 LANDING INTERMEDIATE LANDING -0Ø 50 0Ø@50c/c RISER =75 TREAD =50 WAIST SLA THICKNESS =0 NUMER OF STEPS= 8 Ø@50c/c 0Ø@50c/c SECTION ØC/C 75 0 Ø@50c/c 0Ø@50c/c LANDING A 0Ø@50 c/c Ø@50c/c Ø@50 c/c LANDING EAM DETAIL X 000 X 0Ø@50c/c Ø@50c/c 575 C D -0Ø+-6Ø -0Ø -0Ø PCC PCC -6Ø S Ø 950 SECTION - 4-6Ø SECTION - -0Ø 4-6Ø FINISHED FLOOR LEVEL FLOOR EAM ALONG GRID (REFER EAM DETAILS) SECTION A-A Ø@50c/c 0Ø@50c/c L-SECTION OF LANDING EAM Y Y STAIRCASE SECTION

30 T5 PROP T T T4 T4 T4 T4 T4 T4 T4 T T T5 PROP PROP PROP 050 T T 694 T PROP PROP T T PROP SLOPE RIDGE SLOPE SLOPE SLOPE T T T 69 PROP 94 T T 050 PROP PROP PROP 450 T T T4 T4 T4 T4 T4 T4 T4 T T

31 T T T T T

32 Top Chord A strut(inclined) D Prop C ottom Chord E Strut(Vertical) F Prop TRUSS MEMER SCHEDULE MEMER STEEL TUES SIZE SECTION THICKNESS, (mm) TOP & OTTOM CHORD 60.0 ODM, Kg/m.60 STRUT (INCLINED) STRUT (VERTICAL) PURLIN OD- Outer Diamter, M- medium 60.0 ODM, Kg/m 60.0 ODM, Kg/m 60.0 ODM, Kg/m NOTES:. ALL WELDING SHOULD E FILLET WELD OF MINIMUN 6 MM THICK. SIZE OF COMPLETE PENETRATION UTT WELD GREATER THAN EQUAL TO MEMER THICKNESS. STEEL GRADE ST5 (Yst GRADE)

33 PURLINS 0 X 80 X 6 MM PURLIN CLEAT RAFTER 8 MM WELD RAFTER PRINCIPAL RAFTER OTTOM TIE STRUTS WASHER 5MM THICK STRUT (INCLINED) STRUT (INCLINED) VERTICAL STRUT DETAIL - A WELD STRUTS INCLINED TIE kg/m (Medium) DETAIL C DETAIL OTTOM TIE STRUTS PURLIN 5.07 kg/m (Medium) 0 x80x 6 mm PURLIN CLEAT DETAIL D PRINCIPAL RAFTER 60.O kg/m (Medium) OTTOM TIE kg/m (Medium) OTTOM TIE MS Flat mm size=50mmx50mm 0mm nuts, 50 mm long and bolts (4 Nos) STRUTS WASHER 5MM THICK MS Flat mm size=50x50mm MS Flat 5x4x75mm RCC PROP MS Flat mm size=50mmx50mm 0mm nuts, 50 mm long and bolts (4 Nos) MS Flat mm size=50x50mm welded to bottom chord MS Flat 5x4x75mm RCC PROP DETAIL E DETAIL F 4nos. 0 mm nut and bolts TOP VIEW OF JOINT & C & ANCHORAGE JOINTS TRUSS CONNECTION DETAILS

34 PURLIN PURLIN 8 MM Weld ottom Chord RAFTER VERTICAL STRUT 0 x80x 6 mm PURLIN CLEAT 6mm MS steel plate welded to steel tubular rafter TIE/ OTTOM CHORD 8 MM WELD 50x50x0MM ASE PLATE VERTICAL STRUT RAFTER PURLIN-RAFTER CONNECTION DETAILS (TOP VIEW) 8Ø@75c/c 4-0Ø, 50MM LONG HIGH DENSITY NUTS & OLTS PURLIN-RAFTER CONNECTION DETAILS (SIDE VIEW) MM WELD RCC PROP 0 x80x 6 mm PURLIN CLEAT PURLIN 8 MM Weld TOP CHORD TRUSS HOLDING ASE PLATE Ø, 75MM LONG HIGH DENSITY NUTS & OLTS PURLIN-RAFTER CONNECTION DETAILS (END VIEW) NOTES:. SAME TRUSS CONNECTION DETAILS SHALL E ADOPTED IN ALL CONNECTIONS. TRUSS HOLDING DETAILS REFERENCES:. REFER DRG. NO. STR/6 FOR TRUSS LAYOUT PLAN. REFER DRG. NO. STR/8 FOR TRUSS ELEVATION. REFER DRG. NO. STR/ FOR PROP DETAILS

35 4-6Ø 50 SECTION A-A 50 OTTOM TIE MS Flat mm size=50mmx50mm on top of tie beam 0mm nuts, 50 mm long and bolts (4 Nos) STRUTS MS Flat 5x4x75mm RCC PROP FLEXILE SUPPORT DETAIL WASHER 5MM THICK MS Flat mm size=50x50mm welded to bottom chord MS Flat mm size=50x50mm placed on a RCC prop NOTES:. FOR A FLEXILE SUPPORT, HOLDING DOWN OLTS TO E TIGHT 75 %. OVAL SHAPED SOLE PLATE HOLE FOR FLEXILE SUPPORT. SAME SUPPORT DETAILS TO PROVIDED AS SHOWN IN ROOF TRUSS LAYOUT PLAN. A 8Ø@75c/c H A SOLE PLATE 4nos. 0 mm nut and bolts Oval shaped sole plate RCC PROP ASE PLATE 50 mm Sole Plate ASE/SOLE PLATE SECTION RCC PROP SOLE PLATE FOR FLEXILE SUPPORT PROP DETAILS NOTE: H= HEIGTH OF PROP (REFER ARCHITECTURAL DRAWING FOR PROP HEIGHT 50 Circular shaped Hole in ase Plate 50 4nos. 0 mm nut and bolts Circular shaped sole plate. REFER DRG. NO. STR/6 FOR TRUSS LAYOUT PLAN.. REFER DRG. NO. STR/8 FOR TRUSS ELEVATION.. REFER DRG. NO. STR/0 FOR TRUSS MEMER SCHEDULE.. REFER DRG. NO. STR/0 & STR/ FOR TRUSS CONNECTION DETAILS. 50 ASE PLATE FOR OTH FIXED/FLEXILE SUPPORT mm Thick ase Plate REFERENCES: 50 SOLE PLATE FOR FIXED SUPPORT mm Thick Sole Plate

36 SINK C/C OTHWAYS MM C/C OTHWAYS -8Ø 775 8Ø@0MM C/C OTHWAYS A KITCHEN SINK DETAIL A -8Ø KITCHEN WORK TOP DETAIL KITCHEN SLA OTTOM REINFORCEMENT PLAN NOTES:. KITCHEN SLA IS 75MM THICK. COVER TO KITCHEN SLA IS 5MM. REFER ARCHITECTURAL DRAWING FOR LOCATION OF SLA

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.) DIVISION 94 VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.) SEC. 91.9401. PURPOSE. (Amended by Ord. No. 172,592, Eff. 6/28/99,

More information

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California Reissued June 1, 2002 ICBO Evaluation Service, Inc. 5360 Workman Mill Road, Whittier, California 90601 www.icboes.org Filing Category: DESIGN Concrete DURISOL WALL FORMS FOR CONCRETE CONSTRUCTION DURISOL

More information

Foundation Specifications

Foundation Specifications Installation Instructions Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas ulletin 37835A Revision L Introduction This document specifies typical foundation characteristics, designs,

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

Product Information Bulletin

Product Information Bulletin Product Information Bulletin CCMC Evaluation Report 13101-R Advantage Insulating Concrete Forming (ICF) System BULLETIN NO. ISSUED: REPLACES: 201 November 25, 2010 January 2, 2009 Canadian Construction

More information

TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ S201 TW: 89'-0" TF: 86'-0" S201 TW: 87'-11 1/4" S201 TF: 86'-10 1/4" S201

TP: 89'-0 BP: 86'-6 1/4 2'-0 Typ TP: 89'-0 BP: 86'-6 1/4 2'-0 Typ S201 TW: 89'-0 TF: 86'-0 S201 TW: 87'-11 1/4 S201 TF: 86'-10 1/4 S201 Resource reginc.com 0.. '-" P: '-" 0'-0" " P: '- /" 0'-" '-" '-0" '-0" 0'-0" '-0" '-" '- /" TF: '-0" TW: '-0" TF: '-0" TW: '-0" TF: '-0" TW: '- /" TF: '-" " Typ Sim. P: '-" " TF: '-0" C '- /" '-" Varies

More information

Architectural & Structural Design

Architectural & Structural Design B&W.dwg, 01/05/ 11:16:31 ص SMOH G.o.S. - Sudan Architectural & Structural Design Location: Tarbeba Locality: Baida - State: West Darfur Sudan B&W.dwg, 01/05/ 11:16:42 ص Key : DOORS SAMPLES TO BE APPROVED

More information

CHECKING MANUAL FOR THE EXAMINATION OF RESIDENTIAL PLANS AND INSPECTION OF RESIDENTIAL CONSTRUCTION IN GRENADA

CHECKING MANUAL FOR THE EXAMINATION OF RESIDENTIAL PLANS AND INSPECTION OF RESIDENTIAL CONSTRUCTION IN GRENADA Grenada Hurricane Resilient Home Reconstruction Program: G-(HR) 2 Construction Quality Assurance Project (CQA) CHECKING MANUAL FOR THE EXAMINATION OF RESIDENTIAL PLANS AND INSPECTION OF RESIDENTIAL CONSTRUCTION

More information

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS Please note: This construction plan component list is to be used as a guide to assist you with your project. There may be elements unique to your project not

More information

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2) Inspection of Fabricators (1704.2) Furnish inspection reports (1704.2.1) - Fabricators that have not been approved Provide a Certificate of Compliance (1704.2.2) - Approved Fabricators Steel Construction

More information

Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for

Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for seismic analysis Analysis done using structural designing

More information

NCMA TEK. REINFORCED CONCRETE MASONRY TEK 14-2 Structural (1997)

NCMA TEK. REINFORCED CONCRETE MASONRY TEK 14-2 Structural (1997) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology REINFORCED CONCRETE MASONRY TEK 14-2 Structural (1997) Keywords: allowale

More information

Pulaski County, Virginia Practical Wall Bracing

Pulaski County, Virginia Practical Wall Bracing Pulaski County, Virginia Practical Wall Bracing Based on the 2012 Virginia Residential Code The information herein provides guidelines for complying with the most common Practical Wall Bracing provisions

More information

HOLDOWN & STRAP SCHEDULE

HOLDOWN & STRAP SCHEDULE SHEAR WALL SCHEDULE STRUCTURAL DESIGN CRITERIA GOVERNING CODE SOIL BEARING PRESSURE HOLDOWN & STRAP SCHEDULE MARK SHEATHING SHEATH BOTH SIDES NAILS EDGE SPACING NOTES MARK SW 7/" OSB NO 8d " OC - A SW

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06 1100 WOOD FRAMING PART 1 - GENERAL 1.1 SUMMARY A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But

More information

Building Division Informational Handout

Building Division Informational Handout CITY OF SAN JOSÉ, CALIFORNIA Building Division Informational Handout Conventional Light Frame Construction Design Provisions 2007 CBC Handout No. 2-21 Published: 1/1/08 Page 1 of 3 This document summarizes

More information

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued) 2000 IRC 1997 NEHRP Section Provision Section Provision Comments CHAPTER 3 BUILDING PLANNING R301 DESIGN CRITERIA R301.2.2 Seismic Provisions R301.2.2.1 Determination of Seismic Design Category R301.2.2.1.1

More information

EARTHQUAKE SAFE CONSTRUCTION OF MASONRY BUILDINGS Simplified Guideline for All New Buildings in the Seismic Zone III of India

EARTHQUAKE SAFE CONSTRUCTION OF MASONRY BUILDINGS Simplified Guideline for All New Buildings in the Seismic Zone III of India EARTHQUAKE SAFE CONSTRUCTION OF MASONRY BUILDINGS Simplified Guideline for All New Buildings in the Seismic Zone III of India Zone III Introduction: As usual new construction of uildings under IAY, Prime

More information

SPECIFICATION FOR PRECAST/ COMPOSITE CONCRETE FLOORS/ ROOF DECKS SECTION E60

SPECIFICATION FOR PRECAST/ COMPOSITE CONCRETE FLOORS/ ROOF DECKS SECTION E60 SPECIFICATION FOR SECTION E60 A 2007-09-26 S.W. Revision Date Issue Authorised By Approved for Issue SW Date 24.09.07 clarkebond Page 1 of 6 To be read with Preliminaries/ General Conditions. GENERAL 10

More information

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code LEGACY REPORT ER-4203 Reissued June 1, 2004 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office #

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied

More information

SPECIAL INSPECTION AND TESTING AGREEMENT

SPECIAL INSPECTION AND TESTING AGREEMENT COUNTY OF MENDOCINO DEPARTMENT OF PLANNING AND BUILDING SERVICES 860 NORTH BUSH STREET UKIAH CALIFORNIA 95482 120 WEST FIR STREET FT. BRAGG CALIFORNIA 95437 STEVE DUNNICLIFF, DIRECTOR PHONE: 707-234-6650

More information

Project Address: Name of Person Completing Form:

Project Address: Name of Person Completing Form: Statement of Inspections This form is provided as a way to list aspects of the project that require special inspection and testing in accordance with IBC Sections 107.1, 1704, and 1705 and define duties

More information

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge

More information

Drainage, Road Drainage and Collection Pit A - EXCAVATION:

Drainage, Road Drainage and Collection Pit A - EXCAVATION: 57 Drainage, Road Drainage and Collection Pit SCHEDULE OF QUANTITY Sl.N o. 1 Particulars Qty Unit Rate Amount A - EXCAVATION: Earth work in EXCAVATION IN FOUNDATION TRENCHES IN ALL KIND OF SOIL including

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

NON ENGINEERED REINFORCED CONCRETE BUILDINGSS

NON ENGINEERED REINFORCED CONCRETE BUILDINGSS Chapter 8 NON ENGINEERED REINFORCED CONCRETE BUILDINGS 8.1 INTRODUCTION With the spread of reinforced concrete construction to semi-urban and rural area in various countries, often buildings are constructed

More information

Approximate estimate of renovation and extension work of faculty room in JIST, Jorhat-10 Estimate is prepared as per PWD SOR

Approximate estimate of renovation and extension work of faculty room in JIST, Jorhat-10 Estimate is prepared as per PWD SOR Approximate estimate of renovation extension work of faculty room in JIST, Jorhat-10 Estimate is prepared as per PWD SOR 2013-14 SL Description of the work No 1 DISMANTLING Unit quantity Rate Amount 1.1

More information

STATEMENT OF SPECIAL INSPECTION FORM

STATEMENT OF SPECIAL INSPECTION FORM Project Title: Permit #: Project Address: STATEMENT OF SPECIAL INSPECTION FORM This Statement of Special Inspections is submitted in fulfillment of the requirements of CBC Sections 1704 and 1705. Special

More information

Providing and laying hammer dressed flat stone paving in cement mortar 1:6 on prepared bedding (excluding the cost of bedding). 40mm 22.

Providing and laying hammer dressed flat stone paving in cement mortar 1:6 on prepared bedding (excluding the cost of bedding). 40mm 22. 1 CG0001 Clearing grass including removal of rubbish within 50m of site 91.00 m² 2 EW0001 Surface dressing of ground, including removal of vegetation and inequalities < 150mm deep, disposal of rubbish

More information

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public

More information

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures Attachment A USG Minimum Design and Construction Requirements for Wood Framed Structures 1. General Design Criteria 1.1. Per Adopted Georgia State Minimum Standard Building Code 1.2. Minimum Live Loads

More information

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT Roof Parapet (Detail 911) 21 0 380 380 40 Tie Beams (Detail 8) Tie Beams (Detail 8) FGL Raft foundation (Detail 6) 4 H=0 min Column (Detail 7) + 0.00 PLAIN CONCRETE,6 ELEVATION VIEW 1/0 FGL Floor Tank

More information

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2)

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2) Scientific Journal of Impact Factor (SJIF): 4.72 International Journal of Advance Engineering and Research Development Volume 5, Issue 01, January -2018 REVISION OF IS: 13920 A REVIEW (PART 2) Dr. Archana

More information

Installing DELTABEAM. Installation of DELTABEAM. Deliveries. Storage on-site

Installing DELTABEAM. Installation of DELTABEAM. Deliveries. Storage on-site Installing DELTABEAM Installation of DELTABEAM These DELTABEAM installation instructions are intended to complement the project s erection plan. Peikko s technical support can help with the erection plan

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) P.C. Engineer: Phone:

More information

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address:

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address: SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division Permit Application #: Project Address: Purpose: To meet the requirements of City of Walnut Creek Municipal Code Section

More information

Statement of Special Inspection Requirements

Statement of Special Inspection Requirements Statement of Special Inspection Requirements California Building Code Chapter 17 Construction plans shall include a statement of special inspection in accordance with CBC chapter 17. The statement of special

More information

Statement of Special Inspections 2013 CBC

Statement of Special Inspections 2013 CBC BUILDIG & SAFET DIVISIO 2729 Prospect Park Drive Rancho Cordova, CA 95670 Phone: (916) 851-8760 Fax: (916) 851-8762 Statement of Special Inspections 2013 CBC PERMIT #: PROJECT ADDRESS: This Statement of

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION ITEM 03100 CONCRETE FORMWORK 1.0 GENERAL 1.1 DESCRIPTION This section defines requirements and limitations for design, construction, erection, and removal of concrete formwork for

More information

THRESHOLD INSPECTION SPECIAL INSPECTION PLAN. Evangel Temple Addition

THRESHOLD INSPECTION SPECIAL INSPECTION PLAN. Evangel Temple Addition Page 1 of 11 THRESHOLD INSPECTION SPECIAL INSPECTION PLAN PROJECT: Addition OWNER: ARCHITECT: Brennfoerder Architectural Services STRUCTURAL ENGR: Tappana Ondrick Structural Engineers DATE: Sept. 4, 2018

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) Plan Check Engineer:

More information

TECHNICAL EVALUATION REPORT No. 27/2008/2060

TECHNICAL EVALUATION REPORT No. 27/2008/2060 TECHNICAL EVALUATION REPORT No. 27/2008/2060 Sheet 1 of 16 Sheets This report is a correct record of the measurements and observations made. The report is intended for the private information of those

More information

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals. As a customer service initiative, the Kansas City, Missouri, City Planning and Development Department/Development Services, in cooperation with the Greater Kansas City Home Builders Association, has developed

More information

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED 30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED 3 ENTRY DOOR METAL ROOF METAL SIDING GABLE ROOF, 4/12 PITCH INDEX PAGE DESCRIPTION 1 FRONT

More information

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department olorado Chapter of the International Conference of Building Officials Lancaster County Building Department Single Family Residential One Story Detached Garage How to Use this Guide Provide two sets of

More information

2003 International Residential Building Code

2003 International Residential Building Code 2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less

More information

Statement of Special Inspections

Statement of Special Inspections Statement of Special Inspections SUCF Project No: Project Title: Registered Design Professionals in Responsible Charge: (Name) (Address) Architect: Structural Engineer: Mechanical Engineer: Identification

More information

DESIGN OF PREFAB RC BUILDING USING EPS FOR DISASTER RESISTANCE

DESIGN OF PREFAB RC BUILDING USING EPS FOR DISASTER RESISTANCE DESIGN OF PREFAB RC BUILDING USING EPS FOR DISASTER RESISTANCE S. Selvi Rajan CSIR-Structural Engineering Research Centre Chennai, India 11 March 2016 CSIR-CBRI Roorkee Engineering of prefab structures

More information

6. Design of Portal Frames (For class held on 20 th, 26 th and 27 th March 07)

6. Design of Portal Frames (For class held on 20 th, 26 th and 27 th March 07) 6. Design of Portal Frames (For class held on 0 th, 6 th and 7 th March 07) By Dr. G.S.Suresh, Professor, Civil Engineering Department, NIE, Mysore (Ph:934188467, email: gss_nie@ yahoo.com) 3.1 Introduction:

More information

ThermaSteel Corporation ASSEMBLY MANUAL

ThermaSteel Corporation ASSEMBLY MANUAL ThermaSteel Corporation ASSEMBLY MANUAL TABLE OF CONTENTS 1- INTRODUCTION 1.1 THERMASTEEL TM WALL PANELS 1.2 Drawing and Element Numbers 2- ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation of Foundation

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

THE FLORIDA BUILDING CODE

THE FLORIDA BUILDING CODE THE FLORIDA BUILDING CODE 1. According to the Florida Building Code, spiral stairway treads must all be identical and rise must be sufficient enough to provide a headroom of minimum. A. 6'- 4" B. 6'- 6"

More information

Calculation of Wind Loads on Structures according to ASCE 7-10

Calculation of Wind Loads on Structures according to ASCE 7-10 Calculation of Wind Loads on Structures according to ASCE 7-10 Permitted Procedures The design wind loads for buildings and other structures, including the Main Wind-Force Resisting System (MWFRS) and

More information

C. SPECIAL INSPECTOR S RESPONSIBILITIES

C. SPECIAL INSPECTOR S RESPONSIBILITIES THRESHOLD INSPECTION SPECIAL INSPECTOR'S INSPECTION PLAN PROJECT: DAYTONA INTERNATIONAL SPEEDWAY GRANDSTAND REPLACEMENT OWNER: International Speedway Corporation ARCHITECT: Rossetti Architects DATE: WPM

More information

CONCRETE BLOCK MASONRY

CONCRETE BLOCK MASONRY CONCRETE BLOCK MASONRY CONTENT Introduction Types Manufacturing process Properties Advantages Introduction These are the concrete blocks either hollow or solid. A hollow unit is that unit which has core

More information

1. Cast-in-place concrete is specified in Section

1. Cast-in-place concrete is specified in Section SECTION 03 38 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for furnishing and installing post-tensioned slabs, jacks, jacking and anchors at Parking Structure, and record

More information

SITE VISIT REPORT DATE: JOB: NO. OF VISIT: PAGE OF : PURPOSE OF VISIT: CONTRACTOR: Items to be checked Observations Actions SETTING OUT

SITE VISIT REPORT DATE: JOB: NO. OF VISIT: PAGE OF : PURPOSE OF VISIT: CONTRACTOR: Items to be checked Observations Actions SETTING OUT SETTING OUT Correct to boundaries Correct to building lines? Diagonals accurate? Levels correct? EXCAVATIONS Adjoining structures OK? Centres of foundations line with walls? Bottoms of trenches uniform,

More information

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division GARAGES/ONE-STORY City of Grand Rapids Building Safety Division 218-326-7601 www.cityofgrandrapidsmn.com This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building

More information

KEEP YOUR FAMILY SAFER FROM EARTHQUAKES AND TYPHOONS BY MAKING SURE YOUR HOUSE FOLLOWS THESE 6 BASIC PRINCIPLES

KEEP YOUR FAMILY SAFER FROM EARTHQUAKES AND TYPHOONS BY MAKING SURE YOUR HOUSE FOLLOWS THESE 6 BASIC PRINCIPLES KEEP YOUR FAMILY SAFER FROM EARTHQUAKES AND TYPHOONS BY MAKING SURE YOUR HOUSE FOLLOWS THESE 6 BASIC PRINCIPLES 5. WELL BRACED WALLS FIRMLY CONNECTED TO THE FOUNDATION 6. STURDY ROOF FIRMLY CONNECTED TO

More information

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge

More information

Special Provision No. 109S17 June 2017

Special Provision No. 109S17 June 2017 AMENDMENT TO OPSS 905, NOVEMBER 2014 Special Provision No. 109S17 June 2017 OPSS 905, November 2014 Construction Specification for Steel Reinforcement for Concrete is deleted in its entirety and replaced

More information

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International Building Guide Colorado Chapter of the International Conference of Building Officials Colorado Building Chapter of the International Guide Code Council Single Family Residential One Story Detached Garage

More information

Estimate FOR THE SEPTIC TANK

Estimate FOR THE SEPTIC TANK Estimate FOR THE SEPTIC TANK S.NO ITEM DESCRIPTION. 1 Excavation in soil,soft & hard murum... Qty UNIT Rate Excavation for footing, machine foundation, plinth beams, wall footing, gutters,brick wall, tanks

More information

Scanned by CamScanner

Scanned by CamScanner JODHPUR MUNICIPAL CORPORATION G-SCHDULE NIT No. Date Sr No. Last Date of Sale :- Earnest Money : Rs... Date of Receipt :- CR No. Dated.. Copy issued to M/s STORM WATER DRAINAGE MASTER PLAN FOR THE CITY

More information

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00 Description Page No Summary Amount Summary 1/7 230,694.60 22,019.25 22,642.65 2/6 96,801.30 80,150.60 114,056.00 Total Per Unit (MYR) 327,495.90 102,169.85 136,698.65 Total Unit(s) X 1 2 2 Total Per Type

More information

VTU EDUSAT PROGRAMME Lecture Notes on Design of Stair cases

VTU EDUSAT PROGRAMME Lecture Notes on Design of Stair cases VTU EDUSAT PROGRAMME 17 2012 Lecture Notes on Design of Stair cases DESIGN OF RCC STRUCTURAL ELEMENTS - 10CV52 (PART B, UNIT 8) Dr. M. C. Nataraja Professor, Civil Engineering Department, Sri Jayachamarajendra

More information

SECTION UNIT MASONRY

SECTION UNIT MASONRY SECTION 04200 UNIT MASONRY PART 1 GENERAL 1.01 SUMMARY A. Furnish labor, materials, and equipment and perform functions required in the installation and maintenance of the work covered by this Section.

More information

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient,

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient, DETAIL DRAWINGS RASTRA is a stay-in-place insulated concrete form that is structurally strong, energy-efficient, soundproof, resistant to fire, high wind, mold and rodents and is made from 85% recycled

More information

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC. 320-226.5189 www.101developmentresources.com While every attempt has been made to insure the correctness of this handout, no guarantees are made to its accuracy

More information

SPECIAL INSPECTION AGREEMENT

SPECIAL INSPECTION AGREEMENT DEVELOPMENT SERVICES DEPARTMENT BUILDING AND SAFETY DIVISION 156 S. BROADWAY, SUITE 130 TURLOCK, CALIFORNIA 95380 PHONE 209-668-5560 FAX 209-668-5107 SPECIAL INSPECTION AGREEMENT PERMIT NUMBER: DATE: OWNER:

More information

Contents. 1.1 Introduction 1

Contents. 1.1 Introduction 1 Contents PREFACE 1 ANCIENT MASONRY 1 1.1 Introduction 1 1.2 History of Masonry Materials 1 1.2.1 Stone 2 1.2.2 Clay Units 2 1.2.3 Calcium Silicate Units 4 1.2.4 Concrete Masonry Units 4 1.2.5 Mortars 5

More information

Schöck Isokorb Type CM

Schöck Isokorb Type CM Schöck Isokorb Type Schöck Isokorb Type The Schöck Isokorb Type is suitable for cantilevered reinforced concrete slabs. (C for concrete slab) It transmits negative moment (M) and positive shear force.

More information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued January 1, 2004 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair

More information

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST This list is provided as a guide to help you understand the information that must be contained on the construction drawings. This list is not all-inclusive of all building codes but is used as a general

More information

SPECIFICATION FOR REINFORCED SOIL WALL

SPECIFICATION FOR REINFORCED SOIL WALL SPECIFICATION FOR REINFORCED SOIL WALL 1.0 EXTENT OF WORK The work shall consist of Reinforced Soil walls built in accordance with this specification and in conformity with the lines, levels and details

More information

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT SAMPLE GUIDE FOR RESIDENTIAL DECKS revised 7 16 Call before you dig! 1 800 272 1000 New Jersey One Call. Utility Mark Out. THIS GENERIC GUIDE IS NOT ALL INCLUSIVE

More information

This specification describes the minimum requirements for Vale's standard practice for Concrete drawings.

This specification describes the minimum requirements for Vale's standard practice for Concrete drawings. 016/09/0 1/5 1.0 PURPOSE This specification describes the minimum requirements for Vale's standard practice for Concrete drawings. The following drawings form part of this specification: 99-999-D-00481

More information

VALLIAMMAI ENGINEERING COLLEGE

VALLIAMMAI ENGINEERING COLLEGE VALLIAMMAI ENGINEERING COLLEGE DEPARTMENT OF CIVIL ENGINEERING CE6603: DESIGN OF STEEL STRUCTURES QUESTION BANK UNIT I: INTRODUCTION PART-A 1. List the various types of connections used for connecting

More information

Ductile Detailing for Earthquake Resistant R C Structures. Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore

Ductile Detailing for Earthquake Resistant R C Structures. Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore Ductile Detailing for Earthquake Resistant R C Structures Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore 570 006 1 Ductile Detailing Objective To provide adequate toughness

More information

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address:

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address: SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION Permit Application #: Project Address: Purpose: To meet the requirements of CBC Section 1704.3 this form may be used as a statement

More information

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2047 Reissued 07/207 This report is subject to renewal 07/209. DIVISION: 05 00 00

More information

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA Structural Analysis Overview: During the structural analysis of the in Lancaster, Pa, a redesign of the lateral and gravity system from masonry bearing and shear walls to a staggered truss system was performed.

More information

REINFORCED CONCRETE MASONRY SECTION

REINFORCED CONCRETE MASONRY SECTION SECTION 04 22 02 - REINFORCED CONCRETE MASONRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 01 Specification

More information

EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI)

EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI) EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI) For this example let s consider a single-story retail shell building. The main structural walls consist of CMU construction with the front of the building

More information

A seismic engineer s note book

A seismic engineer s note book A seismic engineer s note book G.R. Houston, A.S. Beer, G.L. Cole & R.D. Jury Beca Ltd, New Zealand. 2014 NZSEE Conference ABSTRACT: The interest in seismic retrofit of buildings stimulated by the Canterbury

More information

Masonry and Cold-Formed Steel Requirements

Masonry and Cold-Formed Steel Requirements PC UFC Briefing September 21-22, 2004 Masonry and Cold-Formed Steel Requirements David Stevens, ARA Masonry Requirements Composite Construction Masonry is often used in composite construction, such as

More information

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831)

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831) County of Santa Cruz PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA 95060 (831) 4542580 FA: (831) 4542131 STATEMENT OF SPECIAL INSPECTIONS California Building Code 1704.3 Prior to issuance,

More information

THIMPHU CITY CORPORATION BUILDING APPLICATION SECTION

THIMPHU CITY CORPORATION BUILDING APPLICATION SECTION Guidance notes to all persons wishing to make an application for a building permit. All applicants will be required to submit the following documentation: 1) A completed application form (available from

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II SECTION 052100 - STEEL JOISTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections

More information

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY INFORMATIONAL NOTES: READ THESE NOTES EFORE USING THESE S. USE THESE S AS A ASIS FOR THE PREPARATION OF STRUCTURE LAYOUTS AND CONTRACT DRAWINGS. ALL SUPPORTS LOCATED WITHIN THE CLEAR ZONE MUST E SHIELDED

More information

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 616 APRIL 2018 CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT TABLE OF CONTENTS 616.01 SCOPE 616.02 REFERENCES 616.03 DEFINITIONS

More information

Part 6 Superstructure (excluding roofs) Chapter 6.5. Steelwork

Part 6 Superstructure (excluding roofs) Chapter 6.5. Steelwork Part 6 Superstructure (excluding roofs) hapter ONTENTS SOPE DESIGN lause Page Design standards D1 1 Structural design D 1 Padstones D3 1 This hapter gives guidance on meeting the Technical Requirements

More information

Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES

Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC Division 93 Effective: 11/22/15 DOCUMENT NO.: P/BC 2014-137 Revised: 06/07/16 Previously Issued As: N/A Mandatory Wood Frame Soft-story

More information

UNIT-I DESIGN CONCEPTS, DESIGN OF BEAMS Part - A (Short Answer Questions)

UNIT-I DESIGN CONCEPTS, DESIGN OF BEAMS Part - A (Short Answer Questions) S.NO IMPORTANT QUESTIONS UNIT-I DESIGN CONCEPTS, DESIGN OF BEAMS Part - A (Short Answer Questions) 1 What are the three methods of design of reinforced concrete structural elements? 2 State four objectives

More information

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE: SECTION 07651 FLEXIBLE COPPER SHEET FLASHINGS Advanced Building Products, Inc. manufacturer many types of flexible copper sheet flashings. Due to their ductility, high tensile strength, and resistance

More information

WALL CONSTRUCTION CHAPTER 6

WALL CONSTRUCTION CHAPTER 6 CHAPTER 6 WALL CONSTRUCTION SECTION R601 GENERAL R601.1 Application. The provisions of this chapter shall control the design and construction of all walls and partitions for all buildings. R601.2 Requirements.

More information

CHAPTER 10: GENERAL STRUCTURAL DETAILS

CHAPTER 10: GENERAL STRUCTURAL DETAILS CHAPTER 10: GENERAL STRUCTURAL DETAILS 10.1 GENERAL It shall be in accordance with JSCE Standard Specification (Design), 9.1, "steel" shall be taken to signify "steel or CFRM". 10.2 CONCRETE COVER (1)

More information

under under x o under

under under x o under LEGEND 4000 BUILDER TO PROVIDE FLASHING/TRIMS & ENSURE WATERPROOFING IN ACCORDANCE WITH THE NCC 1160 80 1720 80 960 900 WINDOW & DOOR SCHEDULE W1 W2 W3 SD 600W x 600D OPERABLE GLASS LOUVRES 1800W x 900D

More information