Free standing Patio covers

Size: px
Start display at page:

Download "Free standing Patio covers"

Transcription

1 Free standing Patio covers Instructions provided by CoverKits.com Down load the standard instruction manuals applicable to the cover, Laguna, Lattice, solid Newport, insulated Traditional, or the Maxx panels. These instructions will address the post and beam installation only. Laguna Lattice cover in a triangle configuration Laguna Lattice cover in a rectangle configuration.

2 Newport Solid covers with steel post for a carport Newport Solid covers with the Alumawood post and beam (The Maxx panel will look the same)

3 Free standing covers will always require footings. Unlike wood covers, the metal covers must have a constrained footing that is embedded in the concrete. Refer to the engineering drawings provided for the footing sizes that range from 23 cube to 48. The size of the footing is determined by the wind loads, live loads, spans and heights of the cover. Coverkits will supply you with the proper materials that are required, but it is your responsibility to give us the proper wind and live load requirements for your area. Check with your local building department for the engineering requirements. Coverkits We will gladly give you all the engineering information you need for a successful installation.

4 Determine the dimension of the patio cover top or lid in the area you want to install your cover. Be mindful of the set back requirements of your local area. Make sure that the centerline of the post is 1 6 to 2 from the edge of the cover. This will establish the overhang of the cover. Do not worry about the post height at this time, cut the post after they are set in the concrete. Note when ordering the cover, it is always figured as the lid dimension, not post location! Use a string for the lay-out making sure that it is square. You can use a drywall square, or use the rule, A square plus B square equals C square. Remove the string, dig the holes, and then replace the string (use the same stakes) to set the post. Drill the bottom area of the post and insert the ½ rebar per the engineering. Note before setting the post, the building inspector will need to see the hole prior to installing the post. Check with your county or city for the in process inspection schedule. However you install the post in the cement, it is critical that the posts are plumb! Verify with a level. The bigger the level, the better for accuracy. An easy way that we use is to set in a sauna tube, and hand mix the concrete. Then when set, have a ready mix truck with a pump and pour the rest. Remember that four footings is about four yards of concrete. Make the footings a little larger than the minimum requirement to insure that the inspector does not hold you up because you are off an inch or so!

5 This cover is a triangle shape lattice cover, see pictures at the end of the instructions If the header beams are double, then make sure that the post height will be to the top of the headers. Or if single, then the header sits on the top of the post. When figuring the post height follows the rules of thumb: 1. If lattice, the cover is level, 8 to 12 for a lattice cover is appropriate. 2. With double headers, add 8 for the header beam and make sure that you have a minimum of 6 9 clearance under the header beam. Also remember that you will probably pour a slab after the posts are set, which is another 3 ½ to 4 making the post at 93 minimum. 3. It would be 8 less if the header sits on the top. 4. On the top of the header then you have the 2 x 6 ½ joist and the 2 by 2 lattice making a total height of 97.5 with the concrete slab. 5. If the cover is solid, Newport or the Maxx panel make sure the cover is sloped a min. of ¼ to ½ per foot of projection. The back side (high side, opposite of the gutter) and sides will have the hanger channels and the 2 by 6 ½ fascias.

6 Verify the post height, then level, mark and cut the post.

7 Brackets will be supplied to install the header beam. Once the header is installed, remove brackets and the faceplates will cover the holes. Headers installed to the post. The vinyl caps are not installed yet. Notice the rafter brackets on the top of header beams.

8 The post face plates were installed last because of the stone on the concrete. The vinyl plugs are not installed yet.

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC. 320-226.5189 www.101developmentresources.com While every attempt has been made to insure the correctness of this handout, no guarantees are made to its accuracy

More information

ALPINE PATIO COVER INSTALLATION INSTRUCTIONS

ALPINE PATIO COVER INSTALLATION INSTRUCTIONS ALPINE PATIO COVER INSTALLATION INSTRUCTIONS Contact us at: 1-800-851-0865 or www.americana.com Before You Begin: Consult your local building department for any required permits You may be required to

More information

PS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.

PS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION. C.9. DOOR AND WINDOW OPENINGS Openings for doors and windows are formed with bucks, or frames, which are constructed to the rough opening dimensions required for the doors and windows to be installed.

More information

OZARK PATIO COVER INSTALLATION INSTRUCTIONS

OZARK PATIO COVER INSTALLATION INSTRUCTIONS OZARK PATIO COVER INSTALLATION INSTRUCTIONS Contact us at: 1-800-851-0865 or www.americana.com Before You Begin: Consult your local building department for any required permits You may be required to obtain

More information

Detached Garages and Building Permits. 1 and 2 Family Dwellings

Detached Garages and Building Permits. 1 and 2 Family Dwellings Detached Garages and Building Permits 1 and 2 Family Dwellings Why do I need a permit? The City of Minneapolis adopts the State of Minnesota Building Code (MNSBC) and its associated state statutes and

More information

TETON PATIO COVER INSTALLATION INSTRUCTIONS

TETON PATIO COVER INSTALLATION INSTRUCTIONS TETON PATIO COVER INSTALLATION INSTRUCTIONS Contact us at: 1-888-442-2928 or www.americana.com Before You Begin: Consult your local building department for any required permits You may be required to obtain

More information

US Pool Lift Model #114 (Independence) Installation Guide

US Pool Lift Model #114 (Independence) Installation Guide US Pool Lift Model #114 (Independence) Installation Guide This manual has been provided to assist with lift installation. For further assistance please contact your authorized US Pool Lift dealer. Toll

More information

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209) City of Hughson Building Safety Division 7018 Pine Street Hughson, CA 95326 (209) 883-4054 RESIDENTIAL ATTACHED PATIO COVERS Patio covers are one story roofed structures not more than 12 feet above grade,

More information

ALPINE PATIO COVER INSTALLATION INSTRUCTIONS

ALPINE PATIO COVER INSTALLATION INSTRUCTIONS ALPINE PATIO COVER INSTALLATION INSTRUCTIONS Contact us at: 1-800-851-0865 or www.americana.com Before You Begin: Consult your local building department for any required permits You may be required to

More information

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016 February 2016 Residential Deck Safety, Construction and Repair Juneau Permit Center, 4 th Floor Marine View Center,(907)586-0770 This handout is designed to help you build your deck to comply with the

More information

Chapter 53: Endwall Overhang(s) Only - Enclosed

Chapter 53: Endwall Overhang(s) Only - Enclosed Chapter 53: Endwall Overhang(s) Only - Enclosed Most Common Mistakes: 1. Incorrect eave height. 2. Placing standard heel end trusses at same height as interior trusses. 3. Fascia board top edges not bevel

More information

TYPICAL BEARING WALL FRAMING

TYPICAL BEARING WALL FRAMING BASIC WOOD FRAMING City of Grand Rapids Building Safety Division 218-326-7601 www.grandrapidsmn.org This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code,

More information

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER:

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 23 6587 (562) 699 053 www.icc es.org ESR 1398P Reissued 06/2018 This report is subject to renewal 06/2019. DIVISION: 00 00 SPECIALTIES

More information

Installation Guide. PrivacyShield Outdoor Enclosure

Installation Guide. PrivacyShield Outdoor Enclosure Installation Guide PrivacyShield Outdoor Enclosure Table of Contents 1.0 Introduction... 2 2.0 Materials, Delivery & Tools... 2 3.0 Layout and Post Locations. 3 4.0 Foundations... 5 5.0 PVC Installation....

More information

DECK CONSTRUCTION REQUIREMENTS

DECK CONSTRUCTION REQUIREMENTS DECK CONSTRUCTION REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern. We

More information

www.arizonawholesalepoolcontractors.com The Swimming Pool Construction Checklist is designed to give you some guidelines and hints of items to look for while you re building your own pool. It s outline

More information

INSPECTION REQUIREMENTS: FOUNDATIONS

INSPECTION REQUIREMENTS: FOUNDATIONS Foundations Page 1 of 9 Revision Date: 1/2/2018 DEVELOPMENT SERVICES BUILDING INSPECTION INSPECTION REQUIREMENTS: FOUNDATIONS INSPECTION CODE: 204 SCOPE: RESIDENTIAL APPLICABLE CODES: 2016 CBC, CRC, CPC,

More information

1 & 2 Family Garage/Shed Permits City of Oshkosh Inspection Services Division

1 & 2 Family Garage/Shed Permits City of Oshkosh Inspection Services Division This handout will help guide you through the permit application process. Following the steps below will help to expedite the issuance of your building permit. Please plan ahead and pick one of the following

More information

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory

More information

RESIDENTIAL CARPORTS / PATIO & DECK COVERS

RESIDENTIAL CARPORTS / PATIO & DECK COVERS BUILDING DIVISION www.laytoncity.org 437 N Wasatch Drive Phone: 801-336-3760 Layton, UT 84041 Fax: 801-336-3789 The information contained in this packet is for Residential s/patio/deck Covers based on

More information

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements General Information Site Card. Before starting construction, post the site card (issued by the City) in a front window visible from the street. Miss Dig. Before you dig, call Miss Dig at 800.482.7171 This

More information

INSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE

INSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE Fox Blocks INSTALLATION CHECKLIST ND EDITION Fox Blocks Installation Checklist: ND Edition 6110 Abbott Drive Omaha, NE 6110-69-6 WWW.FOXBLOCKS.COM INSTALLATION CHECKLISTS The Checklists on the following

More information

The Homeowner s Building Application Checklist for Constructing a Residential Addition

The Homeowner s Building Application Checklist for Constructing a Residential Addition The Homeowner s Building Application Checklist for Constructing a Residential Addition This checklist provides homeowners a summary of the Building Permit submission requirements for constructing a residential

More information

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department olorado Chapter of the International Conference of Building Officials Lancaster County Building Department Single Family Residential One Story Detached Garage How to Use this Guide Provide two sets of

More information

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading April 1, 2017 This Tip Sheet reflects code requirements of the 2015 International Residential Code (IRC) with Washington State Amendments which

More information

STANDARD BWL-1: NOTES TO DESIGNER

STANDARD BWL-1: NOTES TO DESIGNER STEEL BEAM/GIRDER SPANS NOTES TO DESIGNER: Standard is to be used with steel beam/girder spans. Maximum beam/girder spacing is limited to 10-0. Designer is required to check clearances at abutments if

More information

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading CONSTRUCTION TIP SHEET 5 w/ 60 lb Live Loading April 1, 2017 This Tip Sheet reflects code requirements of the 2015 International Residential Code (IRC) with Washington State Amendments which update the

More information

Steps in Building a Shed

Steps in Building a Shed Steps in Building a Shed The design and location of your new shed will depend on how it will be used - a shed for storing tools will be much simpler than one you intend to use as a small shop. For example,

More information

Building permits are not required for patios made of concrete or pavers on grade.

Building permits are not required for patios made of concrete or pavers on grade. DECKS CITY OF BEMIDJI BUILDING DEPARTMENT (218) 759-3573 www.ci.bemidji.mn.us This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code, Bemidji City Ordinances

More information

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space assembly two or more interconnected structural components combined to meet a specific function or design requirement attic an open space between the roof and ceiling of a building balloon frame a type

More information

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507) Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed

More information

1 AND 2 FAMILY DWELLING REQUIREMENTS

1 AND 2 FAMILY DWELLING REQUIREMENTS PLAN REQUIREMENTS: 1 AND 2 FAMILY DWELLING REQUIREMENTS All residential plans including additions and attached garages shall be designed to the current edition of the International Residential Code. Plans

More information

Screen & 3-Season Porches

Screen & 3-Season Porches Screen & 3-Season Porches PERMIT SUBMITAL CHECKLIST : City of New Prague Building Inspections Department 118 Central Ave N New Prague, MN 56071 (952) 758-4401 Fax (952) 758-1149 Signed completed Building

More information

TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ S201 TW: 89'-0" TF: 86'-0" S201 TW: 87'-11 1/4" S201 TF: 86'-10 1/4" S201

TP: 89'-0 BP: 86'-6 1/4 2'-0 Typ TP: 89'-0 BP: 86'-6 1/4 2'-0 Typ S201 TW: 89'-0 TF: 86'-0 S201 TW: 87'-11 1/4 S201 TF: 86'-10 1/4 S201 Resource reginc.com 0.. '-" P: '-" 0'-0" " P: '- /" 0'-" '-" '-0" '-0" 0'-0" '-0" '-" '- /" TF: '-0" TW: '-0" TF: '-0" TW: '-0" TF: '-0" TW: '- /" TF: '-" " Typ Sim. P: '-" " TF: '-0" C '- /" '-" Varies

More information

Pulaski County, Virginia

Pulaski County, Virginia Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Foundation and Floor... 3

More information

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout Building Department 200 W. Oak Street 3 rd Floor Fort Collins, CO 80521 970-498-7700 DEFINITIONS High Wind Areas Those areas

More information

Basic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc.

Basic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc. Basic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc. Franklin County Septic & Zoning permit application: A septic and zoning permit is required for residential or commercial

More information

DECK GUIDE PERMIT FEES

DECK GUIDE PERMIT FEES DECK GUIDE PERMIT FEES Deck (over 48 above grade): $ 130.00 * Deck (any portion under 48 above grade): $ 190.00 * (Pursuant to Contracted Agent fee schedule) * Plus PA Act 13 Surcharge: $ 4.50 Note: Fees

More information

DECKS. BUILDING DEPARTMENT 1584 Hadley Avenue N Oakdale, MN Phone: Fax:

DECKS. BUILDING DEPARTMENT 1584 Hadley Avenue N Oakdale, MN Phone: Fax: DECKS This handout is written only as a guide. It is not intended nor shall it be considered a complete set of requirements. CALL BEFORE YOU DIG, CALL 811 Gopher One or 651-454-0002 to locate all utilities

More information

Deck Construction Guide

Deck Construction Guide Deck Construction Guide This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, the 2015 American Wood Council and the 2012 IRC, Sherburne County ordinances,

More information

Proud of its Heritage, Preparing for its Future

Proud of its Heritage, Preparing for its Future TUSTIN Proud of its Heritage, Preparing for its Future USER GUIDE FOR THE REROOFING OF BUILDINGS Revised August 2013 PURPOSE This user guide describes the City of Tustin s requirements regarding reroofing

More information

Building Guide. Colorado Chapter of the International Code Council

Building Guide. Colorado Chapter of the International Code Council 12/29/16 Building uide Colorado Chapter of the International Code Council How to Use this uide Check with your jurisdiction regarding type of submittal (paper or electronic) and for additional requirements.draw

More information

Patio Covers Building Guides for Homeowners

Patio Covers Building Guides for Homeowners Patio Covers Building Guides for Homeowners Why Do I need a Permit? D ID Y OU K N OW? As owner-builder you are the responsible party of record on such a permit. If your work is being performed by a contractor,

More information

STANDARDIZED STRUCTURES

STANDARDIZED STRUCTURES Q, QH & QL TOWERS 16.1 Q, QH, and QL Towers General Description The series includes three and four leg angle towers, which are suited for a variety of antenna mounting positions and load conditions. The

More information

Plot Plan for Decks Date. Name Phone # Address Zip APN # _- _- _ (see property tax bill or call the assessor s office ) FRONT PROPERTY LINE

Plot Plan for Decks Date. Name Phone # Address Zip APN # _- _- _ (see property tax bill or call the assessor s office ) FRONT PROPERTY LINE City of Beaumont Plot Plan for Decks Date Name Phone # Address Zip APN # _- _- _ (see property tax bill or call the assessor s office 955-600) FRONT PROPERTY LINE House REAR PROPERTY LINE - Show patio

More information

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX Hansen Pole Buildings Planning Guide Toll Free 866-200-9657 / Toll Free FAX 866-200-9658 While we strive to earn your business, whether you purchase from us or not, we would hope you would utilize this

More information

Building Guide. Building Guide. Colorado Chapter of the International Code Council. Single Family Residential Patio Covers & Carports

Building Guide. Building Guide. Colorado Chapter of the International Code Council. Single Family Residential Patio Covers & Carports 7/19/16 Building Guide Colorado Chapter of the International Conference of Building Officials Building Guide Colorado Chapter of the International Code Council Single Family Residential Patio Covers &

More information

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International Building Guide Colorado Chapter of the International Conference of Building Officials Colorado Building Chapter of the International Guide Code Council Single Family Residential One Story Detached Garage

More information

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES A deck/patio permit is required for all construction including decks, renovation of existing decks/patio, paver patios, and retaining walls (over 30 inches).

More information

SPECIALTY STRUCTURE CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

SPECIALTY STRUCTURE CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT) format. It will consist of 80 equally weighted questions. The examination will have questions

More information

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min. FRAMING TIPS City of Grand Rapids Building Safety Division 218-326-7601 www.grandrapidsmn.org This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code, Grand

More information

COUNTY BLOCK. Construction Guidelines on County Block Steps. Special Considerations When Building Steps. Natural Beauty Absolute Strength

COUNTY BLOCK. Construction Guidelines on County Block Steps. Special Considerations When Building Steps. Natural Beauty Absolute Strength Construction Guidelines on County Block Limits of Liability This County Block Installation Guide provides general information about the product, including installation procedures, technical and engineering

More information

HIGHLANDVIEW CEMETERY CHAPEL

HIGHLANDVIEW CEMETERY CHAPEL HIGHLANDVIEW CEMETERY CHAPEL CONTACT: Ferris State University Small Town Studio Christopher Cosper, AIA, LEED, AP, Assistant Professor cosperc@ferris.edu 23.59.33 Sheet List Sheet Name Sheet # COVER A00

More information

BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS

BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS Permit Required Any owner or authorized agent who intends to construct, enlarge,

More information

Important: Before You Start

Important: Before You Start Advantage ICF System Advantage ICF System TM Field Guide Important: Before You Start Does Your Building Inspector Know You Are Building with the Advantage ICF System? You are required to check with your

More information

DOOR AND WINDOW OPENINGS PREPARE IN ADVANCE VBUCK CONSTRUCTION

DOOR AND WINDOW OPENINGS PREPARE IN ADVANCE VBUCK CONSTRUCTION DOOR AND WINDOW OPENINGS Openings for doors and windows are formed with bucks, or frames, which are constructed to the rough opening dimensions required for the doors and windows to be installed. These

More information

Residential Patio Cover Specifications

Residential Patio Cover Specifications Residential Patio Cover Specifications This information bulletin describes the minimum requirements for obtaining patio cover permits for residential buildings using the City of Vista standard plan or

More information

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches and shall be sized to carry the applicable roof and

More information

Table of Contents. 1 Introduction. 2 Description. 3 Tools and materials. 4 Footings or slabs. 5 Coursing placement. 6 Reinforcing steel

Table of Contents. 1 Introduction. 2 Description. 3 Tools and materials. 4 Footings or slabs. 5 Coursing placement. 6 Reinforcing steel Table of Contents 1 Introduction 2 Description 3 Tools and materials 4 Footings or slabs 5 Coursing placement 6 Reinforcing steel 7 Alignment scaffold installation 8 Concrete placement 9 Exterior and interior

More information

STEP BY STEP INSTALLATION GUIDE. LOW PROFILE and RAISED DECKS. instant foundation system ULTRA DURABLE

STEP BY STEP INSTALLATION GUIDE. LOW PROFILE and RAISED DECKS. instant foundation system ULTRA DURABLE instant foundation system HIGHLY ENGINEERED TRADITIONAL DECK BLOCK REPLACEMENT REPLACES HEAVY CONCRETE BLOCKS USED IN THE FLOATING FOUNDATION DECK BLOCK SYSTEM TRUSTED FOR OVER 35 YEARS! YEARS MANUFACTURER

More information

Building Guide. Building Guide. Colorado Chapter of the International Code Council. Single Family Residential Patio Covers & Carports

Building Guide. Building Guide. Colorado Chapter of the International Code Council. Single Family Residential Patio Covers & Carports 7/19/16 Building Guide Colorado Chapter of the International Conference of Building Officials Building Guide Colorado Chapter of the International Code Council Single Family Residential Patio Covers &

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) P.C. Engineer: Phone:

More information

Revision Date: April 01, Premier Vinyl Enclosure

Revision Date: April 01, Premier Vinyl Enclosure Premier Vinyl Enclosure www.urbanindustries.com 53 Urban Industries, Inc. 2008 Tools The following tools are recommended for the installation of the Premier Vinyl Enclosure and roof. 1 2 Level 1 4 Level

More information

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) PERMIT SUBMITTAL CHECKLIST: Signed completed Building Permit application form. Two (2) Copies of a Certificate of Survey. Draw to scale the

More information

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide 12/29/16 Building Guide Colorado Chapter of the International Conference of Building Officials Building Guide Colorado Chapter of the International Code Council Single Family Residential Enclosing Existing

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied

More information

Garage/Accessory Structures

Garage/Accessory Structures Garage/Accessory Structures City of New Prague Building Inspections Department 118 Central Ave N New Prague, MN 56071 (952) 758-4401 Fax (952) 758-1149 Requirements for submitted Building Plans Signed

More information

BENZIE COUNTY BUILDING SAFETY and CODE ENFORCEMENT DEPARTMENT 448 Court Place, Beulah, Michigan Ph Fax.

BENZIE COUNTY BUILDING SAFETY and CODE ENFORCEMENT DEPARTMENT 448 Court Place, Beulah, Michigan Ph Fax. BENZIE COUNTY BUILDING SAFETY and CODE ENFORCEMENT DEPARTMENT 448 Court Place, Beulah, Michigan 49617 Ph. 231-882-9673 Fax. 231-882-0033 DECK SPEC INFORMATION Footing Inspections: Dig footing to required

More information

DOG CABIN. Size DuraTemp Vinyl

DOG CABIN. Size DuraTemp Vinyl DOG KENNEL Size Capacity Traditional Elite Metal Roof 4x8 1 Dog $2,416 n/a $210 6x8 1 Dog 3,644 4,402 242 6x10 1 Dog 4,274 5,292 242 8x10 1 Dog 4,788 5,902 294 8x12 1 Dog 5,188 6,228 358 8x14 1 Dog 5,692

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) Plan Check Engineer:

More information

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers version 2.5 updated as of 08.04.2017 2 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers 2.0 ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation

More information

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge

More information

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual Series 200 UL Introduction Series 200 UL Introduction SnapNrack Series

More information

A-ONE Insulated Forms Installation Manual

A-ONE Insulated Forms Installation Manual A-ONE Insulated Forms Installation Manual Rockford, MN www.aoneform.com www.diversifoam.com info@diversifoam.com A-ONE Manual 180426.docx Disclaimer Notice The information in the A-ONE Insulated Forms

More information

Specifications subject to change without further notice. Intellectual property is protected by copyright patents and registered designs

Specifications subject to change without further notice. Intellectual property is protected by copyright patents and registered designs Post Post Economy Model Purlindek Roofing Enhanced Model Surround Flashing Gutter Purlindek Roofing 4850 / 5450 / 6050 4850 / 5450 / 6050 / 7250 Post Foundation Details Peg out the overall carport size

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

Groundwater Seepage. Causes of Basement Seepage and Leaks Hydrostatic Pressure

Groundwater Seepage. Causes of Basement Seepage and Leaks Hydrostatic Pressure Groundwater Seepage The following guide can be used by you and your crews when assessing seepage at a property. Bear in mind that this guide is not all-inclusive, and should be used in a supplementary

More information

Pulaski County, Virginia Practical Wall Bracing

Pulaski County, Virginia Practical Wall Bracing Pulaski County, Virginia Practical Wall Bracing Based on the 2012 Virginia Residential Code The information herein provides guidelines for complying with the most common Practical Wall Bracing provisions

More information

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785) Perma-Column Installation Instructions Unlike any other concrete post-frame foundation system, Perma-Column Precast Concrete Piers use 10,000 psi concrete and our unique Sturdi-Wall Plus wet-set bracket

More information

Carpentry/Carpenter CIP Task Grid

Carpentry/Carpenter CIP Task Grid Secondary Task List 100 SAFETY/OCCUPATIONAL ORIENTATION 101 Identify and follow all basic safety practices and procedures. 102 Identify and follow all lab safety practices and procedures. 103 Identify

More information

F500 Steeplechase Waterjump with Valve Option

F500 Steeplechase Waterjump with Valve Option Gill Athletics www.gillathletics.com Phone: (800) 367-3090 Fax: (217) 367-8440 Excavation F500 Steeplechase Waterjump with Valve Option Installation Guide Read all instructions before installing!!! Establish

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

Comparing the Creation of a Concrete Patio to a Wooden Deck

Comparing the Creation of a Concrete Patio to a Wooden Deck Comparing the Creation of a Concrete Patio to a Wooden Deck Task: You have just purchased a 3 year old bungalow. You have enough money to immediately do your first home improvement project, to create a

More information

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code Albemarle County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential decks only. Framing requirements are limited to single

More information

Vocabulary. Chapter 8: Decks 1/17. The main parts of a deck are (see Chapter 5 for hardware and fasteners):

Vocabulary. Chapter 8: Decks 1/17. The main parts of a deck are (see Chapter 5 for hardware and fasteners): Chapter 8: Decks 1/17 Vocabulary The main parts of a deck are (see Chapter 5 for hardware and fasteners): 1) Post 4x4 PT lumber that supports a frame, vertically secured to post bases 2) Framing member

More information

PROJECT IDEA CATALOG. FREE! Take one. Get inspired! 84LUMBER.COM

PROJECT IDEA CATALOG. FREE! Take one. Get inspired! 84LUMBER.COM PROJECT IDEA CATALOG FREE! Take one. Get inspired! 84LUMBER.COM Gambrel Barns These oversized barns maximize your storage space. They re easy to build, using our engineered truss brackets, providing a

More information

Building Division Informational Handout

Building Division Informational Handout CITY OF SAN JOSÉ, CALIFORNIA Building Division Informational Handout Conventional Light Frame Construction Design Provisions 2007 CBC Handout No. 2-21 Published: 1/1/08 Page 1 of 3 This document summarizes

More information

Town of Kingsville. Building Department

Town of Kingsville. Building Department Town of Kingsville Building Department GUIDE TO ACCESSORY STRUCTURES AND DECKS FOR BUILDING PERMITS www.kingsville.ca 2017 Disclaimer: The fees and by-law information compiled within this guide are for

More information

ThermaSteel Corporation ASSEMBLY MANUAL

ThermaSteel Corporation ASSEMBLY MANUAL ThermaSteel Corporation ASSEMBLY MANUAL TABLE OF CONTENTS 1- INTRODUCTION 1.1 THERMASTEEL TM WALL PANELS 1.2 Drawing and Element Numbers 2- ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation of Foundation

More information

HUMBOLDT COUNTY BUILDING & SAFETY DEPARTMENT CITY OF WINNEMUCCA BUILDING DEPARTMENT

HUMBOLDT COUNTY BUILDING & SAFETY DEPARTMENT CITY OF WINNEMUCCA BUILDING DEPARTMENT HUMBOLDT COUNTY BUILDING & SAFETY DEPARTMENT CITY OF WINNEMUCCA BUILDING DEPARTMENT FOR PRIVATE THREE-SIDED POST FRAMED (NON-ENGINEERED) OUTBUILDINGS LOCATED ON RESIDENTIAL LOTS ONLY Buildings must meet

More information

RETAINING WALL SIGMA WALL 6 AND 8 SIGMA. cambridgewallsupport.com cambridgepavers.com FIND MORE DETAILS AT

RETAINING WALL SIGMA WALL 6 AND 8 SIGMA. cambridgewallsupport.com cambridgepavers.com FIND MORE DETAILS AT BACKYARD PATIOS & OUTDOOR LIVING ROOMS PAVINGSTONES WALL SYSTEMS SIGMA WALL 6 AND 8 SIGMA RETAINING WALL FIND MORE DETAILS AT cambridgewallsupport.com cambridgepavers.com 41 W Cambridge Sigma Wall System

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E. STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION Presented by: Susan L. Lasecki P.E., S.E. Presentation Outline Gravity Design Load Paths from Roof to Foundation Roof Framing Floor Framing Wall Framing Lateral

More information

PLEASE READ ENTIRE INSTRUCTION MANUAL BEFORE PROCEEDING!

PLEASE READ ENTIRE INSTRUCTION MANUAL BEFORE PROCEEDING! INSTALLATION GUIDE This guide is intended to aide in the installation of Dura-Trench systems. There are many different applications and situations for the use of this product and the installation procedures

More information

Below-grade pours (such as foundations) can be done out of the chute of the concrete truck or conveyer, however using a pump is best.

Below-grade pours (such as foundations) can be done out of the chute of the concrete truck or conveyer, however using a pump is best. Concrete Placement Below-grade pours (such as foundations) can be done out of the chute of the concrete truck or conveyer, however using a pump is best. Above-grade pours require lifting equipment. Most

More information

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing. FINISH BASEMENT/ADDITION/REMODEL PLAN CORRECTIONS LIST (Based on the current Editions of the International Codes and National Electrical Code) PLAN CHECKED BY: LOT/SUBDIVISION/ADDRESS: CONTRACTOR OR OWNER/BUILDER:

More information

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems P O Box 34 Mendon, Utah Custom 22' x 40' - 16' Tall Garage Plan #g22 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical

More information

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15 CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15 Copyright 2004 CONSTRUCTION The following are twenty key construction components and basic facts that are to be considered high priority. Please refer

More information

City of San Pablo Community Development Department Building Inspection Division Plan Review & Permit Requirements

City of San Pablo Community Development Department Building Inspection Division Plan Review & Permit Requirements Table of Contents City of San Pablo Community Development Department Building Inspection Division Plan Review & Permit Requirements General Requirements Application & Processing Procedures o Plan Requirements

More information

CITY OF BATAVIA DECK CONSTRUCTION REQUIREMENTS

CITY OF BATAVIA DECK CONSTRUCTION REQUIREMENTS CITY OF BATAVIA DECK CONSTRUCTION REQUIREMENTS City of Batavia Building Division Community Development Department 100 North Island Avenue Batavia, Illinois 60510 Tel: (630) 454-2700 Fax: (630) 454-2775

More information