ANALYSIS OF THE DYNAMIC THERMAL PERFORMANCE OF FIBEROUS INSULATIONS CONTAINING PHASE CHANGE MATERIALS

Size: px
Start display at page:

Download "ANALYSIS OF THE DYNAMIC THERMAL PERFORMANCE OF FIBEROUS INSULATIONS CONTAINING PHASE CHANGE MATERIALS"

Transcription

1 ANALYSIS OF THE DYNAMIC THERMAL PERFORMANCE OF FIBEROUS INSULATIONS CONTAINING PHASE CHANGE MATERIALS Jan Kośny, David W. Yarbrough, William A. Miller, and Kenneth E. Wilkes Oak Ridge National Laboratory, Oak Ridge, TN , USA Tel: , Edwin S. Lee Oklahoma State University, School of Mechanical and Aerospace Engineering 218 Engineering North, Stillwater, OK 74078, USA ABSTRACT PCM can be distributed in thermal insulation, incorporated into structural and sheathing materials, or packaged for localized application. Results from a series of small-scale laboratory measurements and field experiments, indicate that a new generation of PCM-enhanced fiber insulations could have an excellent potential for successful application in U.S. buildings because of their ability to reduce energy consumption for space conditioning and reduction of peak loads. New PCM applications require careful selection of materials, identification of PCM location, bounding thermal resistances, and specification of the amount of PCM to be used. This paper describes the use of a small-scale heat-flow meter apparatus for dynamic testing, and calibration of a computer model for evaluating the performance of PCMenhanced insulations. Whole-house energy simulations have been used to optimize the use of PCMs in the building envelope and to quantify energy savings resulting from the use of dispersed PCMs in Southern California US climate. 1. TECHNICAL BACKGROUND Since 2002, an ORNL research team has been working to evaluate fiber insulations blended with microencapsulated PCMs [Kosny et al. 2006, 2007 a, b also Miller and Kosny 2007]. These PCM-insulation mixtures function as lightweight thermal-mass components. This type of insulation system will contribute to the objective of reducing energy use in buildings and development of zero-net energy buildings because of their ability to reduce energy consumption for space conditioning and reshape peak-hour loads. Other anticipated advantages of PCMs are improvement of occupant comfort, compatibility with traditional wood and steel framing technologies, and potential for application in retrofit projects. Previous studies [Feustel 1995, Kissock 1998, Kosny 2006, Slayer 1989, Tomlinson 1992, Zhang 2005] have demonstrated that the use of PCM in well-insulated buildings can reduce heating and cooling energy in U.S. residential buildings by as much as 25%. If PCM-enhanced building envelope components are installed in about 10% of U.S. homes, then the anticipated energy savings are between and terajoules/year. PCM-enhanced interior sheathing based on n-octadecane has been considered in the past [Kissock 1998, Slayer 1989, Tomlinson 1992] but flammability has been a concern. Therefore, the project team decided to pursue the development of ignition

2 resistant microencapsulated PCMs. In addition, this project dealt with PCM displaced from the interior sheathing. In a series of experiments carried out in a manufacturing environment, PCM was blended with cellulose insulation intended for use in walls and attics. The first PCM-enhanced cellulose insulation is close to introduction in the US. The PCM-enhanced cellulose being discussed has successfully passed the smoldering combustion test required by the standard specification ASTM C 739 and a series of critical radiant flux tests done in accordance with ASTM C1485 [Kosny 2007b]. The goal of this work was experimental and numerical analysis of the energy performance of PCM-enhanced fibrous insulations with relatively complex and nonuniform blends of two or more different materials, including cellulose fibers, very fine PCM powders, adhesives, and fire retardants. In numerous publications, the thermal characteristics of PCM materials are obtained using a differential scanning calorimeter (DSC). The investigated PCM-enhanced cellulose doesn t contain pure PCM. The 5 to 50 µm PCM pellets contain about 75 to 85 wt% of the organic PCM with the balance of the weight being an acrylic or composite skin. When mixed with the cellulose insulation, these micro pellets usually create 100 to 200 µm clusters. The amount of PCM in the insulation blend has to be accurately determined in order to perform any further thermal analysis. This is not a trivial task. During the manufacturing process, a specific amount of PCM is added to the fibrous insulation. However, at the end of the production process, due to many different reasons, the amount of PCM material in the cellulose blend can be only roughly estimated. That is why a special testing method to determine PCM content was developed. It is anticipated that a similar method can be used in the future for quality control purposes during the production of the PCM-enhanced fiber insulations. 2. THERMAL CONDUCTIVITY OF CELLULOSE - PCM BLENDS During production of the PCM-enhanced cellulose, cellulose fibers are mixed with specific amounts of PCM powder making composite blends of two significantly different materials. In previous ORNL studies paraffinic-pcm products were used. These PCMs were produced by a process that held microscopic droplets of n- octadecane inside hard acrylic polymer shells. In the current project, in addition to n- octadecane, the fatty acid esters were used due to their lower flammability. Like paraffinic products, they undergo a solid-liquid transition with most of the phase change process between 25 C to 29 C. In case of the popular paraffinic PCMs the phase change enthalpy h fus is close to 120 J/g. Since apparent thermal conductivity (k a ) of the PCM-cellulose composite is critical for its proper thermal performance, a series of k a measurements were performed. These measurements were conducted on 5.1-cm. thick specimens of cellulose insulation and PCM-enhanced cellulose insulation using a heat-flow meter apparatus operated in accordance with ASTM C 518. The k a data were determined as a function of the mean specimen temperature as shown in Figure 1. At 24 C, the k a of a 30wt% PCM-cellulose blend is W/m K. This result is the same as the k a for cellulose without PCM. The addition of microencapsulated PCM does not result in a significant change in the k a of the insulation. These results were obtained for a test specimen with density 33.6 kg/m 3 tested with a temperature difference of 22.2 C and are represented by Equation 1. k a = T (1)

3 0.044 Apparent Thermal Conductivity, W/mK Cellulose with 30% PCM at 33.6 kg/m 3 Delta T = 22.2 C except first point at 10.0 C Temperature, C Figure 1. Apparent Thermal Conductivity of PCM-Enhanced Cellulose as a Function of Temperature. 3. DYNAMIC HEAT FLUX TESTING OF PCM-ENHANCED CELLULOSE The dynamic thermal characteristics of fiber insulations are relatively well known, but the dynamic thermal characteristics of the PCM-enhanced insulations are difficult to predict. The unknown factors affecting these characteristics are the concentration of PCM, size and amount of clusters constituted of PCM micro-pellets, amounts of fire retardant, and adhesives. During the manufacturing process, a specific amount of PCM is added to cellulose insulation. In the final product, however, the amount of PCM in the cellulose blend can be different from the intended amount. For this reason a procedure that uses a heat-flow meter apparatus (HFM) to determine the actual PCM content in a blend was developed [Kosny et al. 2007a, ASTM C518]. The method utilizes heat flux measurements for cellulose insulation with known amounts of PCM material to determine the amount of PCM in an unknown blend. The following procedure was used for this testing. The 7.6-cm thick test specimen was brought to a uniform temperature of 15 C. This was accomplished by setting both plates in the HFM to the same temperature. At time zero, the bottom plate of the HMF was changed to 37.7 C with a resulting inward heat flux to the test specimen. This is the charge of the PCM which has a phase change temperature of about 25.8 C. The bottom plate is changed back to 15 C when steady-state conditions are observed. Heat flux data have been collected for cellulose specimens containing 0, 10, 20, 30, and 40 wt.% phase change material to cellulose having fiber density of 25.6 kg/m 3. A complete set of heat flux-time data for first 80 minutes of these experiments (first dynamic thermal ramp) is presented on Figure 2 for the hot plate of the HFM apparatus. This set of data can be utilized to estimate the amount of PCM in an unknown specimen by generating a curve to compare with the data in Figure 2. The data collected during these experiments helped in development of a numerical algorithm for temperature-dependent enthalpy which was utilized later in wholebuilding energy simulations.

4 50 PCM Charging Process (flux in) heat flux [W/m2] % PCM 20% PCM 30% PCM 40% PCM time [minutes] Figure 2. Measured heat fluxes for PCM-enhanced cellulose. 4. WHOLE BUILDING ENERGY SIMULATIONS Energy Plus is a whole building energy simulation program for estimating building energy consumption [Crowley 2000]. The program includes a finite difference routine for the effect of PCMs exhibiting variable thermal storage capacities in building materials [Pedersen 2007]. This feature was exploited for simulating PCM-enhanced attic insulation added to an approximately 129 m 2 single-story house. Weather data for Bakersfield, CA was used. The key input data for the structure that was simulated is shown in Table 1. Analyses of PCM-enhanced building envelopes have demonstrated a potential for reductions of cooling loads in southern US locations [Kosny et al. 2008]. In order to explore further these findings, a whole building energy model of a house containing PCM-enhanced attic insulation was developed. A series of Energy Plus simulations were completed using the enthalpy data shown in Figure 3 for a 20 wt% blend of cellulose insulation. Table 1. Building Characteristics Used in Whole Building Energy Modeling. Building Feature Basic Characteristics Dimensions One story, 129 m 2 of floor area, 8.0 m x 16.1 m Floor 10 cm. concrete slab, R-1.0 foam perimeter insulation 60 cm. wide Insulation - wood-frame walls with R 2.3 cavity insulation, - attics with R-values ranging from R 2.1 to R 8.8, - attic with PCM-enhanced insulation R 6.7 plus 20 wt% of PCM Exterior Walls 5x10 cm. wood framing with 25% framing factor Roof Attic - 30 degree pitch, 5x15 cm.. wood rafters and joists - Roof rafters and joists installed 60 cm. OC Windows Glazing - 20% of floor area (total window area about 25 m 2 - including 3 south facing windows, 2 north facing, 1 west facing, and 1 east facing window) Doors 91 x 200 cm. south facing, 91 x 200 cm. north facing Interior Walls 5x10 cm. wood framing with studs representing 10% of wall area HVAC System Multizone (to allow temp variations between rooms). Cooling Temp 25.6 o C, Heating Temp 23.9 o C, Single Speed AC Unit - Autosized, Gas Furnace -Autosized, 77% Eff.

5 Enthalpy [J/g] Temperature [C] Figure 3. Enthalpy data for 20 wt% blend of cellulose insulation and PCM. In Energy Plus simulations presented in Figures 4 and 5 roof-generated loads represented about 25% of the total whole building HVAC loads. Figure 5 shows heat fluxes computed for four summer days for attic floor area kj Jul 4-Jul 5-Jul 6-Jul 7-Jul R-2.1 (R-12 US) R-3.3 (R-19 US) R-5.3 (R-30 US) R-6.7 (R-38 US) R-8.8 (R-50 US) PCM R-6.7 (R-38 US) Figure 4. Total Ceiling Heat Conduction Attic Simulations Bakersfield, CA (Summer). Simulation results showed that during the peak time hours, attic floor heat conduction for the case of the R SI -6.7 PCM-enhanced attic insulation is significantly lower, when compare to the heat fluxes generated for R SI -8.8 conventional insulation. The all-day attic heat flow amplitudes in house containing PCM are also notable lower from the conventional R SI -8.8 insulation cases. A 1.5 hour shift in peak heat flow can be also observed for PCM attic compared to a R SI -8.8 conventionally insulated attic. For the same days as shown in Figure 5, a comparison of the whole house HVAC loads was made between conventional R SI -6.7 and R SI -8.8 attic insulations and PCMenhanced R SI -6.7 insulation. It can be observed that a superior energy performance of

6 the PCM-enhanced insulation was transformed into the notable lower whole house cooling loads. In the house containing R SI -8.8 conventional attic insulation, overall cooling loads are notably higher than the case where R SI -6.7 PCM-enhanced insulation was used. Maximum peak-hour cooling loads in the house containing PCM are 35% to 40% lower than the loads in the conventional house using R SI -8.8 attic insulation R-8.8 (R-50 US) PCM R-6.7 (R-38 US) kj Jul 4-Jul 5-Jul 6-Jul 7-Jul Figure 5. Whole Building Sensible Loads Attic Simulations Bakersfield, CA (Summer). The results of the Energy Plus simulations are plotted in Figure 6 to show a relationship between the attic insulation R-value and annual whole building energy consumption. For Bakersfield, CA a R SI -6.7 attic containing 20 wt% PCM-enhanced insulation had the same annual energy use as an attic with R SI An annual savings of 556 kwh were saved by adding the 20% by weight PCM to the R SI -6.7 attic insulation. The value of this saved energy is estimated at $70 using a cost of electricity of $/kwh [Miller & Kosny 2007]. Therefore, in terms of available United States construction cost data [BNI 2008, Means 2005], about $14 per square meter of attic footprint [i.e., $1830 for the 129 m 2 ranch style home] would be spent to increase the thermal resistance of conventional blown-in fiberglass insulation from R SI -6.7 to R SI (considering 18% floor area coverage by structural attic components). For comparison, for the same attic footprint, adding 20% by weight of the microencapsulated PCM to the R-6.7 attic insulation would cost about $1360 (assuming cost of PCM as $8.83 per kg.).this is about 26% saving comparing to the cost of adding extra R-6.5 insulation on top of the R SI -6.7 insulation (to reach overall R SI -13.2). In addition, as showed on Figure 6, PCMenhanced insulation generates significant shavings and shifting of cooling peak loads, which is not the case for conventional insulations. Thus, the above cost comparison does not show the full benefit of using blends of the fiber insulations and microencapsulated PCM.

7 Whole Building HVAC Energy [GJ] Dynamic R-value Equivalent for PCM attic tells what attic R-value a house with conventional attic 106 should have, to obtain the same space heating 104 and cooling energy consumption as a similar house using PCM-enhanced attic insulation Attic R-value m 2 K/W Typical attic insulation R-6.7 attic insulation with 20% of PCM Figure 6. Relationship between attic R-value and whole building energy consumption for a 129 m 2 single-story house located in Bakersfield, CA. 5. CONCLUSIONS This paper presents results from a series of small-scale laboratory experiments and numerical analysis that deal with PCM-enhanced fiberous insulation. These results indicate that PCM insulation blends have a high potential for successful adoption in U.S. buildings because of their ability to reduce energy consumption for space conditioning and reduce peak loads. Steady-state heat-flow meter testing was performed on specimens of PCM-cellulose blends to analyze its thermal conductivity. At 24 C, the k a of a 30wt% PCM-cellulose blend was the same as the k a for cellulose without PCM. The addition of microencapsulated PCM didn t result in a significant change in the k a of the insulation. A new testing method was developed for estimation of the PCM content in the PCMcellulose composite. This dynamic test method was using modified heat flow apparatus which is traditionally utilized for thermal conductivity testing (ASTM C518). Dynamic heat flux measurements have been made for cellulose insulation with and without microencapsulated phase change material (PCM). Experimental heat fluxes recorded during the test on the top and bottom plates of the HFM apparatus were compared for different PCM-cellulose blends. These data helped in development of numerical algorithms which were utilized in whole house energy simulations. Test results demonstrated that it is possible to use this method to determine the amount of PCM in fiber insulations. A series of whole building Energy Plus simulations was performed for Bakersfield CA - southern California US location. In house containing R SI -8.8 conventional attics insulated, overall cooling loads were notably higher from the cases where R SI -6.7 PCM-enhanced insulation was used. For the Bakersfield CA climate, maximum peaktime cooling loads in the house containing PCM were 35% to 40% lower comparing to the loads in the conventional house using R SI -8.8 attic insulation. In addition, these simulation results for demonstrated that conventional attic insulation must be about R SI in order to yield the same annual whole house energy consumption compared to the home with R SI -6.7 attic insulation with PCM-enhancement. Cost-

8 wise PCM-enhanced attic insulation is about 26% less expensive from equivalent conventional fiber insulation. In addition, PCM-enhanced insulations generate significant shavings and shifting of cooling peak loads, which are not available for conventional insulations. References 1. ASTM (American Society of Testing and Materials) Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus, ASTM C ASTM (American Society of Testing and Materials) Standard Specification for Cellulosic Fiber Loose File Thermal Insulation, ASTM C BNI Building News. Home Remodeler s 2008 Costbook. Home Builder Press of the National Association of Home Builders. 15th Edition p Childs, K. W.,-1993 HEATING 7.2 Users' Manual, Oak Ridge National Laboratory, ORNL/TM_12262, February Crawley D.B., Lawrie L.K., Pedersen C.O., Winkelmann F.C. ENERGYPLUS: ENERGY SIMULATION PROGRAM - ASHRAE Journal, Vol. 42, No. 4 (April 2000), pp EIA Feustel, H. E Simplified Numerical Description of Latent Storage Characteristics for Phase Change Wallboard, Indoor Environmental Program Energy and Environment Division, Lawrence Berkeley National Laboratory. 8. Guibalt M, 2007 private communication with M. Guibalt 2007 of BASF, USA 9. Kissock, J. Kelly, J. Michael Hannig, and Thomas I. Whitney Testing and Simulation of Phase Change Wallboard for Thermal Storage in Buildings, in Proceedings of 1998 International Solar Energy Conference, June 14 17, Albuquerque, J. M. Morehouse and R. E. Hogan, Eds., American Society of Mechanical Engineers, New York. 10. Kosny, J., Yarbrough D., and Wilkes K., PCM-Enhanced Cellulose Insulation: Thermal Mass in Light-Weight Fibers, International Energy Agency and Department of Energy Ecostock 2006 Conference, Stockton University, May 31, Kosny J., Yarbrough D., Petrie T.W., Syad A. 2007a. Performance of Thermal Insulation Containing Microencapsulated Phase Change Material 2007 International Thermal Conductivity Conference June 24-27, Birmingham, AL, 12. Kosny J., Yarbrough D., Miller W., Petrie T., Childs P., Syad A. 2007b. Thermal Performance of PCM-Enhanced Building Envelope Systems DOE, ASHRAE, ORNL Conference Thermal Envelopes X, Clear Water, Florida, December Kosny J., Yarbrough D., Miller W., Petrie T., Childs P., Petrie T., Syad A /07 Field Testing of Cellulose Fiber Insulation Enhanced with Phase Change Material Oak Ridge National Laboratory report ORNL/TM-2007/186, September Kossecka, E. and J. Kosny Equivalent Wall as a Dynamic Model of Complex Thermal Structure, Journal of Thermal Insulation and Building Envelopes, January Means, R.S., Residential Cost Data, Kingston, MA. 16. Miller W. A., Kosny J., 2007 Next Generation Roofs and Attics for Residential Homes Proceedings of the 2007 ACEEE Summer Studies on Energy Efficiency, August 2007 Pebble Beach, California. 17. Pedersen C. O., 2007 Advanced Zone Simulations in Energy Plus; Incorporation of Variable Properties and Phase Change Material (PCM) Capability Proceedings of the 10th International Building Performance Simulation Association Conference and Exhibition, Beijing, September Petrie, T. W., K. W. Childs, P. W. Childs, J. E. Christian, and D. J. Shramo Thermal Behavior of Mixtures of Perlite and Phase change Material in a Simulated Climate, pp in Insulation Materials: Testing and Applications: Third Volume, ASTM STP 1320, R.S. Graves and R.R. Zarr, Eds., American Society for Testing and Materials, West Conshohocken, PA. 19. Salyer, I., and A. Sircar Development of PCM Wallboard for Heating and Cooling of Residential Buildings, pp in Thermal Energy Storage Research Activities Review, U.S. Department of Energy, New Orleans, March 15 17, Tomlinson, J., C. Jotshi, and D. Goswami Solar Thermal Energy Storage in Phase Change Materials, pp in Proceedings of Solar 92: The American Solar Energy Society Annual Conference, June 15 18, 1992, Cocoa Beach, FL. 21. Zhang, Meng, M. A. Medina, and Jennifer King Development of a Thermally Enhanced Frame Wall With Phase-Change Materials for On-Peak Air Conditioning Demand Reduction and Energy Savings in Residential Buildings, International Journal of Energy Research 29(9),

Use of PCM-Enhanced Insulations in the Building Envelope

Use of PCM-Enhanced Insulations in the Building Envelope Feature Use of PCM-Enhanced Insulations in the Building Envelope By Jan Kośny, PhD and David W. Yarbrough, PhD, PE, Oak Ridge National Laboratory ABSTRACT A phase change material (PCM) alters the heat

More information

Energy Performance Analysis of Building Envelopes Utilizing Blown Fiber Insulation with Microencapsulated Phase Change Material (PCM).

Energy Performance Analysis of Building Envelopes Utilizing Blown Fiber Insulation with Microencapsulated Phase Change Material (PCM). Fraunhofer Center for Sustainable Energy Systems Energy Performance Analysis of Building Envelopes Utilizing Blown Fiber Insulation with Microencapsulated Phase Change Material (PCM). Elizabeth Kossecka

More information

Experimental and Numerical Energy Performance Analysis of PCM-Enhanced Building Envelope Products and Systems

Experimental and Numerical Energy Performance Analysis of PCM-Enhanced Building Envelope Products and Systems Experimental and Numerical Energy Performance Analysis of PCM-Enhanced Building Envelope Products and Systems Jan Kosny, Nitin Shukla, and Ali Fallahi, Fraunhofer CSE Elisabeth Kossecka, Polish Academy

More information

Local Temperature Measurements on Full-Size Systems in the Laboratory: Insight into the Extent of Thermal Bridges in Building Envelope Components

Local Temperature Measurements on Full-Size Systems in the Laboratory: Insight into the Extent of Thermal Bridges in Building Envelope Components Local Temperature Measurements on Full-Size Systems in the Laboratory: Insight into the Extent of Thermal Bridges in Building Envelope Components Thomas W. Petrie, Jan Ko ny, Jerald A. Atchley and André

More information

EFFECTS OF FRAMING ON THE THERMAL PERFORMANCE OF WOOD AND STEEL-FRAMED WALLS

EFFECTS OF FRAMING ON THE THERMAL PERFORMANCE OF WOOD AND STEEL-FRAMED WALLS EFFECTS OF FRAMING ON THE THERMAL PERFORMANCE OF WOOD AND STEEL-FRAMED WALLS JAN KOSNY, PhD DAVID W. YARBROUGH PhD, PE PHILLIP CHILDS Senior research engineer Senior research engineer Research engineer

More information

Performance characterization of PCM impregnated gypsum board for building applications

Performance characterization of PCM impregnated gypsum board for building applications Available online at www.sciencedirect.com Energy Procedia 30 (2012 ) 370 379 SHC 2012 Performance characterization of PCM impregnated gypsum board for building applications Nitin Shukla a, *, Ali Fallahi

More information

Phase-Change Wallboard and Mechanical Night Ventilation in Commercial Buildings: Potential for HVAC System Downsizing

Phase-Change Wallboard and Mechanical Night Ventilation in Commercial Buildings: Potential for HVAC System Downsizing Phase-Change Wallboard and Mechanical Night Ventilation in Commercial Buildings: Potential for HVAC System Downsizing Corina Stetiu Helmut E. Feustel Lawrence Berkeley National Laboratory, Berkeley, CA

More information

Phase Change Materials

Phase Change Materials [STRATEGY] BRIEF DESCRIPTION Phase change materials (PCMs) are materials that are capable of absorbing and releasing thermal energy when they undergo a phase change from solid to liquid and from liquid

More information

High Performance Roofs How to Beat the Heat

High Performance Roofs How to Beat the Heat High Performance Roofs How to Beat the Heat H. Akbari, P. Berdahl, R. Levinson, INDUSTRY COLLABORATIVE R&D LBNL CEC Chris Scruton DOE BT Marc Lafrance Building Envelope Program Oak Ridge National Laboratory

More information

PHASE-CHANGE FRAME WALLS (PCFWS) FOR PEAK DEMAND REDUCTION, LOAD SHIFTING, ENERGY CONSERVATION, AND COMFORT

PHASE-CHANGE FRAME WALLS (PCFWS) FOR PEAK DEMAND REDUCTION, LOAD SHIFTING, ENERGY CONSERVATION, AND COMFORT PHASE-CHANGE FRAME WALLS (PCFWS) FOR PEAK DEMAND REDUCTION, LOAD SHIFTING, ENERGY CONSERVATION, AND COMFORT Mario A. Medina, Ph.D., P.E. Associate Professor Civil, Env. and Arch. Engineering Department

More information

This article will address the test methods used to determine R-values and their relative degree of accuracy.

This article will address the test methods used to determine R-values and their relative degree of accuracy. Insulation R-value, What does it really mean? Every designer knows that the R-value of a material is important in specifying insulation products. Regulations abound that require minimum R-values for wall,

More information

Building Science Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, Straube buildingscience.com 1 of 24

Building Science Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, Straube buildingscience.com 1 of 24 Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Straube buildingscience.com 1 of 24 Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Straube buildingscience.com

More information

Convective Loss in Loose-Fill Attic Insulation

Convective Loss in Loose-Fill Attic Insulation Page 1 of 6 search The Magazine Subscribe to Home Energy Back to Contents Page Home Energy Index About Home Energy Home Energy Home Page Back Issues of Home Energy Home Energy Magazine Online May/June

More information

BEST4 Conference Nibsbest4 April 13-15, 2015

BEST4 Conference Nibsbest4 April 13-15, 2015 National Institute of Building Sciences Provider #G168 BEST4 Conference Nibsbest4 April 13-15, 2015 Credit(s) earned on completion of this course will be reported to AIA CES for AIA members. Certificates

More information

Improving Thermal Performance of Single Family Homes in Hawaii through High Solar Reflectance Coatings on Above Grade Walls

Improving Thermal Performance of Single Family Homes in Hawaii through High Solar Reflectance Coatings on Above Grade Walls Improving Thermal Performance of Single Family Homes in Hawaii through High Solar Reflectance Coatings on Above Grade Walls Overview Hawaii has a unique, cooling-dominated climate that is shared with less

More information

Energy Analysis of Using Thermal Mass in a Hot Humid climate

Energy Analysis of Using Thermal Mass in a Hot Humid climate Energy Analysis of Using Thermal in a Hot Humid climate SARA MOTAMEDI Architecture Department University of Texas at Austin 1 University Station B7500 Austin, Texas, U.S.A, 787us2-0222 s.motamedi@mail.utexas.edu

More information

ACT 2 Project: Maximizing Residential New Construction Energy Efficiency

ACT 2 Project: Maximizing Residential New Construction Energy Efficiency ACT 2 Project: Maximizing Residential New Construction Energy Efficiency Lance E. Elberling, Pacific Gas and Electric Company Richard C. Bourne, Davis Energy Group, Inc. A large U.S. utility designed,

More information

Why Control Heat flow? How to Control Heat Flow? Thermal Performance. Modes of heat transfer: Thermal Control: Insulation & Thermal Bridges

Why Control Heat flow? How to Control Heat Flow? Thermal Performance. Modes of heat transfer: Thermal Control: Insulation & Thermal Bridges Fundamentals Insulation and Thermal Bridges June 13-14, 2012 Why Control Heat flow? Joseph Lstiburek, Ph.D., P.Eng John Straube, Ph.D., P.Eng 2012 Thermal Control: Insulation & Thermal Bridges 1. Occupant

More information

Thermal Bridging in Residential Construction

Thermal Bridging in Residential Construction PHRC Webinar Series Tuesday, May 12, 2015 @ 1pm Thermal Bridging in Residential Construction Brian Wolfgang Housing Systems Specialist Pennsylvania Housing Research Center 219 Sackett Building University

More information

USING PCM TO IMPROVE BUILDING S THERMAL PERFORMANCE

USING PCM TO IMPROVE BUILDING S THERMAL PERFORMANCE 2 nd International Conference on Sustainable Energy Storage, June 19-21, Trinity College Dublin, Ireland USING PCM TO IMPROVE BUILDING S THERMAL PERFORMANCE Monteiro da Silva, S.,* & Almeida, M. ** *Department

More information

DYNAMIC EFFECT OF THERMAL BRIDGES ON THE ENERGY PERFORMANCE OF RESIDENTIAL BUILDINGS IN BC. Fuad Baba*, Hua Ge

DYNAMIC EFFECT OF THERMAL BRIDGES ON THE ENERGY PERFORMANCE OF RESIDENTIAL BUILDINGS IN BC. Fuad Baba*, Hua Ge DYNAMIC EFFECT OF THERMAL BRIDGES ON THE ENERGY PERFORMANCE OF RESIDENTIAL BUILDINGS IN BC Fuad Baba*, Hua Ge Department of Building, Civil and Environmental Engineering, Concordia University, Montreal,

More information

WHOLE-WALL R-VALUES IAN R. COX-SMITH

WHOLE-WALL R-VALUES IAN R. COX-SMITH CIB World Building Congress, April 2001, Wellington, New Zealand Page 1 of 8 WHOLE-WALL R-VALUES IAN R. COX-SMITH Building Research Association of New Zealand, (BRANZ), Private Bag 50908, Porirua, New

More information

1.020 Ecology II: Engineering for Sustainability Spring 2008

1.020 Ecology II: Engineering for Sustainability Spring 2008 MIT OpenCourseWare http://ocw.mit.edu 1.020 Ecology II: Engineering for Sustainability Spring 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms. MASSACHUSETTS

More information

INSULATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

INSULATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings SUCCESS WITH 2012 IECC DELAWARE Recommended Practices for Optimized Energy Savings for Builders & Trades COPYRIGHT 2015 ADVANCED ENERGY. ALL RIGHTS RESERVED VERSION 2015.1.0 DELAWARE For vented attics,

More information

The Department of Energy s Roofing Science Program

The Department of Energy s Roofing Science Program The Department of Energy s Roofing Science Program Andre Desjarlais Oak Ridge National Laboratory 19 January 2012 Managed by UT-Battelle Buildings energy use is large and growing 40% of U.S. Primary Energy

More information

Energy Savings for Stucco Walls Coated with Cool Colors

Energy Savings for Stucco Walls Coated with Cool Colors Energy Savings for Stucco Walls Coated with Cool Colors Tom Petrie, Jerry Atchley, Phil Childs, and André Desjarlais Oak Ridge National Laboratory Building Envelopes Group 6 December 2007 Pop Quiz With

More information

Modeling PCM-Enhanced Insulation System in. EnergyPlus. Thermal Mass IV. Som Shrestha, PhD, BEMP. December 5, 2010

Modeling PCM-Enhanced Insulation System in. EnergyPlus. Thermal Mass IV. Som Shrestha, PhD, BEMP. December 5, 2010 Modeling PCM-Enhanced Insulation System in EnergyPlus Thermal Mass IV Som Shrestha, PhD, BEMP December 5, 2010 EnergyPlus Developed by DOE EERE BTP Whole building energy analysis and thermal load simulation

More information

16 CFR-Part Test procedures for critical radiant flux (loose-fill cellulose)

16 CFR-Part Test procedures for critical radiant flux (loose-fill cellulose) IAS Accreditation Number TL-566 Company Name Address 102 Mill Dr. Cookeville, TN 38501 Contact Name Stuart Ruis, President Telephone +1 (931) 372-8871 Effective Date of Scope August 16, 2017 Accreditation

More information

Chapter 1: Compliance

Chapter 1: Compliance Chapter 1: Compliance [101] Who Must Comply? All new residential construction must comply with the Washington State Energy Code (WSEC). Exceptions. Exempt from envelope requirements but needing to comply

More information

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES Lusi Susanti 1, Hiroshi Matsumoto 2, and Hiroshi Homma 2 1 Department of

More information

Use of Phase Change Materials for Thermal Comfort and Electrical Energy Peak Load Shifting

Use of Phase Change Materials for Thermal Comfort and Electrical Energy Peak Load Shifting U21 International Conference on Energy Technologies and Policy 8th to 10th September 2008, Birmingham, UK Use of Phase Change Materials for Thermal Comfort and Electrical Energy Peak Load Shifting Mohammed

More information

Heat & Temperature. Heat Flow. Heat Flow. Overview. Why control heat flow? Dr John Straube Presentation 1. Insulation and Beyond:

Heat & Temperature. Heat Flow. Heat Flow. Overview. Why control heat flow? Dr John Straube Presentation 1. Insulation and Beyond: Insulation and Beyond: Building Enclosures for Comfort, Efficiency, Health and Durability Dr John F Straube Dupont Young Professor Department of Civil Engineering &School of Architecture University of

More information

PCMs in Building America Projects - Roof Retrofit Technology with Use of the PCM Heat Sink

PCMs in Building America Projects - Roof Retrofit Technology with Use of the PCM Heat Sink Fraunhofer Center for Sustainable Energy Systems PCMs in Building America Projects - Roof Retrofit Technology with Use of the PCM Heat Sink Jan Kosny Ph.D. - Fraunhofer CSE MCA-ORNL Project Leader 2008-2010

More information

Healthy, Durable, Low Energy Buildings: Thermal: High R. Thermal bridges. Fundamentals, techniques, and pitfalls

Healthy, Durable, Low Energy Buildings: Thermal: High R. Thermal bridges. Fundamentals, techniques, and pitfalls Dr John Straube, P.Eng. Associate Professor, University of Waterloo Principal, Building Science Corporation Healthy, Durable, Low Energy Buildings: Fundamentals, techniques, and pitfalls Thermal: High

More information

Table 1. Insulation Type and R-Values. Avg. R-Value Per Inch (h*ft 2 *deg F/Btu*in)

Table 1. Insulation Type and R-Values. Avg. R-Value Per Inch (h*ft 2 *deg F/Btu*in) Introduction This memo outlines Cadmus proposed method to update UA values and total heat-loss estimates for the RBSA II. These updated methods add several elements for consistency with RBSA I and incorporate

More information

Thermal Control in Buildings by John Straube (updated )

Thermal Control in Buildings by John Straube (updated ) building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 011 Thermal Control in Buildings 2006-11-02 by John Straube (updated 2011-12-12)

More information

High Performance Gas-Filled Thermal Insulating Panels

High Performance Gas-Filled Thermal Insulating Panels High Performance Gas-Filled Thermal Insulating Panels David W. Yarbrough, PhD, PE R&D Services, Inc. Doug Kinninger Fi-Foil Company Prepared for Symposium Environment, Energy Security & Sustainability

More information

INSULATION. Success with 2015 IECC Northeast & Mid-Atlantic. Techtips for Builders & Trades

INSULATION. Success with 2015 IECC Northeast & Mid-Atlantic. Techtips for Builders & Trades Success with 2015 IECC Northeast & Mid-Atlantic Techtips for Builders & Trades COPYRIGHT 2015 ADVANCED ENERGY. ALL RIGHTS RESERVED TEMPLATE 2015.1.0 PAGE 1 NORTHEAST For vented attics, install wind baffles

More information

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard Wei Feng, Ke Huang, Mark Levine and Nan Zhou, Lawrence Berkeley National Laboratory Shicong Zhang, Lawrence Berkeley

More information

Field Evaluation of Energy-Saving Technologies for Steep-Slope Roofs

Field Evaluation of Energy-Saving Technologies for Steep-Slope Roofs Field Evaluation of Energy-Saving Technologies for Steep-Slope Roofs Kaushik Biswas, Ph.D. Oak Ridge National Laboratory Jun 14, 2017 ORNL is managed by UT-Battelle for the US Department of Energy Background

More information

Simplified methods to evaluate energy use for space cooling in the energy certification

Simplified methods to evaluate energy use for space cooling in the energy certification Simplified methods to evaluate energy use for space cooling in the energy certification Alessio Gastaldello and Luigi Schibuola University IUAV of Venice, Italy Corresponding email: luigi.schibuola@iuav.it

More information

Building Envelopes 101

Building Envelopes 101 Session: Foundation Building Block 1 Building Envelopes 101 Diana Hun, PhD Oak Ridge National Laboratory August 9, 2016 Rhode Island Convention Center Providence, Rhode Island US Primary Energy Consumption

More information

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation Agenda Why Do Codes Require Thermal or Ignition Barriers? What is a Thermal Barrier? Where is it required? What is an Ignition

More information

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE The sections and construction details in Details 502.2.1.5(1), 502.2.1.5(2), 502.2.1.5(3), 502.2.1.5(4) and 502.2.1.5(5), and Tables 502.2.3.1(1), 502.2.3.1(2), 502.2.3.1(3), 502.2.3.2, 502.2.3.3, 502.2.3.5

More information

Validation of Heating 7.2 Simulations Using Hot Box Test Data for RASTRA Wall Form System with Expanded Polystyrene Beads

Validation of Heating 7.2 Simulations Using Hot Box Test Data for RASTRA Wall Form System with Expanded Polystyrene Beads Validation of Heating 7.2 Simulations Using Hot Box Test Data for RASTRA Wall Form System with Expanded Polystyrene Beads Jan KoÑny and Phill Childs Oak Ridge National Laboratory Buildings Technology Center

More information

SECTION Blown Insulation THERMAL INSULATION

SECTION Blown Insulation THERMAL INSULATION SECTION 07 21 26 - Blown Insulation THERMAL INSULATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Spray-in-place rigid closed-cell polyurethane foam insulation in assemblies indicated on the Drawings, to provide

More information

Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS BEST1 CONFERENCE June 12, 2008

Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS BEST1 CONFERENCE June 12, 2008 Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS BEST1 CONFERENCE June 12, 2008 Agenda European Passive House Program Creating Passive House Designs in U.S.

More information

Construction Report NYSERDA Residential Performance Challenge

Construction Report NYSERDA Residential Performance Challenge Construction Report NYSERDA Residential Performance Challenge WELYTOK TOWNHOMES October 2014 Submitted to: NYSERDA 17 Columbia Circle Albany, NY 12203 Submitted by: HOMEPIC Team CDH Energy Corp. PO Box

More information

In-Situ Study of Thermal Comfort Enhancement in a Renovated Building Equipped with Phase Change Material Wallboard

In-Situ Study of Thermal Comfort Enhancement in a Renovated Building Equipped with Phase Change Material Wallboard In-Situ Study of Thermal Comfort Enhancement in a Renovated Building Equipped with Phase Change Material Wallboard F. Kuznik, J. Virgone, K. Johannes To cite this version: F. Kuznik, J. Virgone, K. Johannes.

More information

2006 Building Science Press All rights of reproduction in any form reserved.

2006 Building Science Press All rights of reproduction in any form reserved. building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 011 Thermal Control in Buildings 2006-11-07 by John Straube Abstract: Providing

More information

CAE 331/513 Building Science Fall 2017

CAE 331/513 Building Science Fall 2017 CAE 331/513 Building Science Fall 2017 November 14, 2017 Heating load calculations Advancing energy, environmental, and sustainability research within the built environment www.built-envi.com Twitter:

More information

INTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE

INTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE INTENATIONAL CODE COUNCIL 09/10 CODE DEVELOPMENT CYCLE 09/10 FINAL ACTION AGENDA UPDATE #2 INTENATIONAL ENEGY CONSEVATION CODE Updated 10-22-10 October 25. 27-31, 10 CHALOTTE CONVENTION CENTE CHALOTTE,

More information

THE ENERGY PERFORMANCE OF THE COLD-FORMED STEEL-FRAME AND WOOD-FRAME HOUSES DEVELOPED FOR THAILAND

THE ENERGY PERFORMANCE OF THE COLD-FORMED STEEL-FRAME AND WOOD-FRAME HOUSES DEVELOPED FOR THAILAND THE ENERGY PERFORMANCE OF THE COLD-FORMED STEEL-FRAME AND WOOD-FRAME HOUSES DEVELOPED FOR THAILAND Prechaya Mahattanatawe 1, Charunpat Puvanant 1, and Darunee Mongkolsawat 1 1 Faculty of Architecture,

More information

ScienceDirect. Comparison of steady-state and in-situ testing of high thermal resistance walls incorporating vacuum insulation panels

ScienceDirect. Comparison of steady-state and in-situ testing of high thermal resistance walls incorporating vacuum insulation panels Available online at www.sciencedirect.com ScienceDirect Energy Procedia 78 (2015 ) 3246 3251 6th International Building Physics Conference, IBPC 2015 Comparison of steady-state and in-situ testing of high

More information

IMPACT OF CLIMATE CHANGE

IMPACT OF CLIMATE CHANGE October 10 11, 2016. Over 90 blind-reviewed papers. Register today. http://facadetectonics.org/save-the-date-2016-facade-tectonics-world-congress/ IMPACT OF CLIMATE CHANGE Thermal and energy performance

More information

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL). Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL). Wall retrofit strategies for retrofit on the interior side of

More information

Insulation and Window Retrofitting:

Insulation and Window Retrofitting: Insulation and Window Retrofitting: Is it worth the cost? Prepared for: owners of single-family houses in the State College rental market Prepared by: Mike **** & Scott **** April 27, 2012 This report

More information

Deer Ridge Consulting, Inc.

Deer Ridge Consulting, Inc. Deer Ridge Consulting, Inc. Code Compliance Research Report 505 Deer Ridge Lane Ararat, VA 24053 Office: 276-755-9162 Fax: 866-441-1054 www.deer-ridge-consulting.com Subject: NCFI 12-008 Spray Polyurethane

More information

Introduction ABSTRACT

Introduction ABSTRACT How Insulating Concrete Form vs. Conventional Construction of Exterior Walls Affects Whole Building Energy Consumption: Results from a Field Study and Simulation of Side-by-Side Houses Thomas W. Petrie,

More information

9.36. Energy Efficiency

9.36. Energy Efficiency Resources and Information NRCAN Energy Efficiency http://www.nrcan.gc.ca/energy/efficiency Canadian Wood Council Wall Thermal Design Tool http://cwc.ca/resources/wall-thermal-design/ 9.36. Energy Efficiency

More information

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. A Subsidiary of the International Code Council

More information

ENERGY PERFORMANCE R-VALUE: PART 2, EXAMPLES OF INTEGRATED METHODOLOGY FOR EVALUATION OF ENERGY EQUIVALENT R-VALUE FOR BUILDING ENCLOSURES;

ENERGY PERFORMANCE R-VALUE: PART 2, EXAMPLES OF INTEGRATED METHODOLOGY FOR EVALUATION OF ENERGY EQUIVALENT R-VALUE FOR BUILDING ENCLOSURES; ENERGY PERFORMANCE R-VALUE: PART 2, EXAMPLES OF INTEGRATED METHODOLOGY FOR EVALUATION OF ENERGY EQUIVALENT R-VALUE FOR BUILDING ENCLOSURES; Part 2: Examples of application to residential walls Thomas Thorsell

More information

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7 Chapter 4 Residential Energy Efficiency [Residential structures include R-3 buildings; R-2 and R-4 buildings three stories or less in height built to the International Building Code (see IBC classifications)]

More information

Heat Flow by direct contact Vibrating molecules Most important for solids 1 > t2 Heat flow

Heat Flow by direct contact Vibrating molecules Most important for solids 1 > t2 Heat flow Fundamentals Heat Control Why Control Heat flow? Joseph Lstiburek, Ph.D., P.Eng John Straube, Ph.D., P.Eng 2011 Thermal Control: Insulation & Thermal Bridges 1. Occupant Comfort 2. Control surface and

More information

Innovating Continuous Exterior Insulation. Theresa A. Weston, PhD. 1

Innovating Continuous Exterior Insulation. Theresa A. Weston, PhD. 1 ABSTRACT Innovating Continuous Exterior Insulation Theresa A. Weston, PhD. 1 As the need to reduce energy usage and carbon consumption has increased, the need for energy efficient building envelopes has

More information

Insulation and Technologies

Insulation and Technologies Interior Design Technology Insulation and Technologies By, Mrs. Noshaba Maryam Chapter Six Building insulation refers broadly to any object in a building used as insulation for any purpose. While the majority

More information

Condensation - Prevention and Control

Condensation - Prevention and Control TECHNICAL NOTES on Brick Construction 47 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 June 2006 Condensation - Prevention and Control Abstract: This Technical Note describes

More information

ENERGY SAVINGS FOR LIFE

ENERGY SAVINGS FOR LIFE Design Characteristics of Spray Polyurethane Foam Insulation ENERGY SAVINGS FOR LIFE Spray Polyurethane Foam Insulation FEATURES Spray Applied Excellent Adhesion Lightweight Safe High Insulation Value

More information

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009 Is Your Envelope Effective? Patrick Roppel P Eng Patrick Roppel P.Eng BCBEC Luncheon January 29, 2009 Goals for this Presentation Why we might be concerned with heat loss through the envelope (U-value

More information

The case for research

The case for research The case for research In recent years there has been growing world-wide concern for energy conservation, the reduction of greenhouse gases and sustainability. In Australia, it is estimated that 39% of

More information

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only Installation Method (Existing Walls) 1. ESP Low-E Housewrap is installed over exterior wall sheathing, make sure reflective side faces out: foil flange faces down. 2. Determine width of ESP Low-E HouseWrap

More information

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE Dr. Essam Al-Sayed Omar Department Manager Kuwait Institute for Scientific Research Kuwait ABSTRACT This paper addresses the

More information

A STUDY OF WALL SURFACE TEMPERATURE VARIATIONS FOR HOUSING IN MODERATE CLIMATES

A STUDY OF WALL SURFACE TEMPERATURE VARIATIONS FOR HOUSING IN MODERATE CLIMATES Florianópolis Brazil 212 A STUDY OF WALL SURFACE TEMPERATURE VARIATIONS FOR HOUSING IN MODERATE CLIMATES Alterman, Dariusz 1 ; Page, Adrian 2 ; Hands, Stuart 3 ; Moffiet, Trevor 4 ; Moghtaderi, Behdad

More information

Deakin University gratefully acknowledges permission of the Australian and New Zealand Solar Energy Society to publish these papers

Deakin University gratefully acknowledges permission of the Australian and New Zealand Solar Energy Society to publish these papers Deakin Research Online Deakin University s institutional research repository DDeakin Research Online Research Online This is the published version (version of record) of:, P. and Luther, M. B. 2001, Evaluating

More information

2010 National Building Code Adoption and Associated Process Changes

2010 National Building Code Adoption and Associated Process Changes Building Inspection City of Moncton 655 Main Street Moncton, NB E1C 1E8 Phone: (506) 856-4375 Fax: (506) 856-4348 Bulletin No. 14 From: Randy Richard Date: February 9, 2015 Subject: 2010 National Building

More information

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE S447 THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE by Bojan V. ANDJELKOVIĆ *,a, Branislav V. STOJANOVIĆ b, Mladen M. STOJILJKOVIĆ b, Jelena N. JANEVSKI

More information

Oregon High Performance Home Requirements

Oregon High Performance Home Requirements Oregon High Performance Home Requirements A Business Energy Tax Credit for Homebuilders Homebuilders who construct homes to the Oregon High Performance Home (HPH) standard are now eligible for the Business

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-26403-1 SOUTH AFRICAN NATIONAL STANDARD Energy efficiency in buildings Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12 428 7911

More information

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

WOOD USE IN NONCOMBUSTIBLE BUILDINGS INTRODUCTION The National Building Code of Canada (NBCC) 1 requires that some buildings be of noncombustible construction under its prescriptive requirements. Its use in certain types of buildings such

More information

Success with Louisiana Energy Code. Techtips for Builders/Trades & Code Officials INSULATION

Success with Louisiana Energy Code. Techtips for Builders/Trades & Code Officials INSULATION Success with Louisiana Energy Code Techtips for Builders/Trades & Code Officials COPYRIGHT 2017 ADVANCED ENERGY. ALL RIGHTS RESERVED VERSION 2015.1.0 PAGE 1 For vented attics, install eave baffles on top

More information

Subject Index. use in HFT installations, 116 use in temperature reservoirs, 28 American Society of Heating, Refrigerating

Subject Index. use in HFT installations, 116 use in temperature reservoirs, 28 American Society of Heating, Refrigerating STP88-EB/Dec. 198 Subject Index Accuracy of HFTs {see Error rates/ ratios of HFTs) Air motion, effect on HPT measurements, 4, 14, 99, 108, 14, 12, 186 Aluminum carrying case for HFTs, 123 jacket for HFTs,

More information

Residential Energy Code Compliance

Residential Energy Code Compliance TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Residential Energy Code Compliance 4A June 2016 Abstract: This Technical Note presents

More information

White Paper. White Paper. Thermal and Ignition Barriers for Spray Foam Insulation. Prescriptive Thermal Barriers

White Paper. White Paper. Thermal and Ignition Barriers for Spray Foam Insulation. Prescriptive Thermal Barriers White Paper Thermal and Ignition Barriers for Spray Foam Insulation The building code regulations regarding spray foam insulation and coatings can be tricky if you aren t familiar with the requirements.

More information

Energy Audit Report Lee Recycling Center Office and Facility 11 Recycling Center Rd, Lee NH August 16 & 17, 2011

Energy Audit Report Lee Recycling Center Office and Facility 11 Recycling Center Rd, Lee NH August 16 & 17, 2011 Energy Audit Report Lee Recycling Center Office and Facility 11 Recycling Center Rd, Lee NH August 16 & 17, 2011 S D E S G r o u p 2 W a s h i n g t o n S t r e e t S u i t e 2 0 6 D o v e r, N H 0 3 8

More information

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Please add relevant logo here Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Presented by: Peter J. Arsenault, FAIA, NCARB, LEED-AP Disclaimer: This presentation was developed by

More information

Success with 2012 NC Energy Conservation Code in North Carolina: Tech Tips for Builders. insulation

Success with 2012 NC Energy Conservation Code in North Carolina: Tech Tips for Builders. insulation Success with 2012 NC Energy Conservation Code in North Carolina: Tech Tips for Builders insulation Copyright 2014 Advanced Energy. All Rights Reserved TEch Tips: 1. Install insulation to meet the 2012

More information

Effective Floor Cavity and Knee Wall Construction Techniques in Two-Story Homes in Hot Climates

Effective Floor Cavity and Knee Wall Construction Techniques in Two-Story Homes in Hot Climates Effective Floor Cavity and Knee Wall Construction Techniques in Two-Story Homes in Hot Climates FSEC-PF-467-16 December 2016 Presented at ASHRAE Thermal Performance of the Exterior Envelopes of Whole Buildings

More information

Index. STP779-EB/Jul. 1982

Index. STP779-EB/Jul. 1982 STP779-EB/Jul. 1982 Index A Absorption of moisture (see Moisture absorption) Adsorption, 191 Capillary versus time, 197 Isotherms For glass fiber, 194, 195 For various materials, 196 Air leakage (exfiltration,

More information

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE Vidar Lerum Arizona State University P O Box 871605, Tempe, AZ, 85287-1605, USA vidar.lerum@asu.edu Venkata

More information

When R-Value Doesn t Measure Up

When R-Value Doesn t Measure Up C. J. Schumacher B.Tech (Arch.Sci.), B.A.Sc.(Civ.Eng.), M.A.Sc.(Bldg.Sci.) When R-Value Doesn t Measure Up NESEA Building Energy10 Outline Why R-Values? Heat, Temperature & Heat Flow Insulating Materials

More information

The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario

The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario Visionwall Technologies Inc. 14904-123 Avenue Edmonton, Alberta, Canada T5V 1B4 Tel: 403 451 4000 Fax:

More information

The Addition of Moisture Transport to the Air Leakage Energy Calculator. Andre Desjarlais Som Shrestha, PhD Oak Ridge National Laboratory

The Addition of Moisture Transport to the Air Leakage Energy Calculator. Andre Desjarlais Som Shrestha, PhD Oak Ridge National Laboratory The Addition of Moisture Transport to the Air Leakage Energy Calculator Andre Desjarlais Som Shrestha, PhD Oak Ridge National Laboratory Air Barrier Association of America (ABAA) is a Registered Provider

More information

Thermal Analysis of CL-TALON Cladding Support System

Thermal Analysis of CL-TALON Cladding Support System Report Number: 180181400 February 16, 2018 Thermal Analysis of CL-TALON Cladding Support System Presented to: CL-TALON 3223 Dell Ave. North Bergen, NJ 07047 Morrison Hershfield Suite 310, 4321 Still Creek

More information

July 23, 2010 PARTIES INTERESTED IN REFLECTIVE FOIL INSULATION

July 23, 2010 PARTIES INTERESTED IN REFLECTIVE FOIL INSULATION July 23, 2010 TO: SUBJECT: PARTIES INTERESTED IN REFLECTIVE FOIL INSULATION Revisions to the Acceptance Criteria for Reflective Foil Insulation, Subject AC02-0610-R1 (LS/RB) Dear Madam or Sir: In June

More information

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis Senior Design Project for UNO Design of the International Studies Building: An Environmental Analysis Design Intent Implement Passive & Active design strategies in order to make the building: More Energy

More information

New Construction Procurement Guidelines for the Pacific Northwest

New Construction Procurement Guidelines for the Pacific Northwest Northwest Portable Classroom Project New Construction Procurement Guidelines for the Pacific Northwest March 31, 2003 WSUCEEP03_063 Washington State University Extension Energy Program 925 Plum Street

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes 2014 British Columbia Building Code Changes A City of Prince George interpretation of the 2014 Building Code Changes for 9.32 & 9.36 The following changes reflect the most notable revisions and staff interpretations.

More information

Goals of Session. Building a Better Thermal Envelope. Thermal Envelope Priorities. Disclaimer. Insulation performance (Real World)

Goals of Session. Building a Better Thermal Envelope. Thermal Envelope Priorities. Disclaimer. Insulation performance (Real World) Goals of Session Building a Better Thermal Envelope RESNET Conference ACI RES 4 February 20, 2007 Bruce Harley, Technical Director Conservation Services Group Understand the key roles in building performance

More information

Numerical Simulation of a Building Envelope with High Performance Materials

Numerical Simulation of a Building Envelope with High Performance Materials Excerpt from the Proceedings of the COMSOL Conference 2010 Paris Numerical Simulation of a Building Envelope with High Performance Materials Mohammad H. Baghban *1, Per J. Hovde 1 and Arild Gustavsen 2

More information