Thermal and sound insulation OPTIMA. Innovative and extremely efficient thermal and sound insulation for the interior surfaces of external walls

Size: px
Start display at page:

Download "Thermal and sound insulation OPTIMA. Innovative and extremely efficient thermal and sound insulation for the interior surfaces of external walls"

Transcription

1 Thermal and sound insulation OPTIMA Innovative and extremely efficient thermal and sound insulation for the interior surfaces of external walls

2 List of content High energy costs but a low comfort level a growing problem. OPTIMA THE INNOVATIVE SOLUTION OPTIMA SYSTEM COMPONENTS 5 I. METAL FRAME 6 II. INSULATION 8 Most of the houses in the European Union are more than 0 years old and do not offer the levels of comfort we expect today. We speak of "thermal comfort" when it is neither too cold nor too warm in summer and winter. Perception of a comfortable temperature results from a small difference between interior ambient air temperature and that of the interior surfaces of the outer walls and windows. In these conditions, one can enjoy a homogeneous air temperature throughout the whole house or flat and the absence of annoying drafts. III. VAPOUR RETARDER AND AIR TIGHTNESS LAYER 9 IV. FACING OPTIMA SYSTEM HIGH LEVEL THERMAL PERFORMANCES OPTIMA SYSTEM SOLUTIONS FOR HIGH ENERGY EFFICIENCY HOUSES OPTIMA SYSTEM AN EFFICIENT SOUND INSULATION A DRY SYSTEM, EASY TO INSTALL 5 DEALING WITH SPECIFIC ISSUES 8 OPTIMA SYSTEM ADVANTAGE AFTER ADVANTAGE 9 OPTIMA SYSTEM A COMPLETE RANGE 0 Older houses were built at a time when the building mentality was very different from that of today, and when there were no efficient thermal insulation materials readily available. Although a lot of energy is used to heat old houses or flats, they are overheated in summer and yet really become warm in winter. Despite occupants having to pay high energy bills, for cooling in summer and heating in winter, thermal comfort is nevertheless limited. In view of rapidly increasing energy prices, living in older houses may well become a very expensive "pleasure", notwithstanding the high consumption of natural resources and the emissions that burden our environment. ISOVER dry wall solution The OPTIMA System Everyone looking for an efficient, yet easy and quick solution for renovating their own four walls needs look no further than the OPTIMA System from ISOVER. OPTIMA is a modern system for easy and rapid renovation or improvement of thermal and sound insulation. The system solution, with its superbly matched components make assembly simple and easy. When it is not possible to install facade or wall-cavity insulation, whether for technical, economic or social reasons (shared ownership), then insulating inside the building is strongly recommended. The OPTIMA System offers ideal solutions for the renovation and insulation of external walls from the inside.

3 OPTIMA The Innovative Solution For installing thermal and sound insulation on the inside of outer walls OPTIMA System components The Technique 6 A dry, high performance system The OPTIMA System consists of simple standard and economical elements: I. Metal frame (the mechanical structure; Picture ) II. Insulation (the thermal and sound layer; Picture ) III. Vapour retarder and air tightness layer (Picture ) IV. Facing (the finished wall; Picture ) I. Metal frame. OPTIMA Bottom and Ceiling Stud. OPTIMA 0 Stud. OPTIMA 0 or 50 Stud. OPTIMA Support (new) or OPTIMA Support Reno (renovation) The dry lining system is very quick to install and guarantees maximum comfort. In addition, it can be easily adapted to fit the structural complexity of a building (e.g. tall supporting walls). Applications Thermal and sound insulation of walls in residential or commercial buildings (council housing, private apartments, individual houses, hotels, hospitals, offices, ) new or for renovation work. Dry installation on all types of substrate, including most irregular or uneven surfaces II. Insulation 5. ISOVER glass wool with d = 0.05 W/mK or 0.0 W/mK III. Vapour retarder and air tightness layer 6. VARIO DB sealing tape 7. VARIO KM or VARIO KM Duplex air tightness layer 8. VARIO KB one-sided adhesive tape IV. Facing 9. Plasterboard or other interior facings (e.g. wooden panels) What you would need to install the OPTIMA System on five metres of wall an example: In short The Advantages of the OPTIMA System. A dry, time-saving solution, which needs no glue mixing and no drying times Improved air tightness compared to traditional solutions ( joints, thermal bridging/ cabling that compromises the insulation layer etc.) Easy cabling and ducting All advantages of the OPTIMA System at a glance on Page 9 OPTIMA Floor and Ceiling Stud 0 m (5 studs) OPTIMA 0 Stud m (0 studs) OPTIMA 0 Stud 0 studs VARIO KB m ( roll) VARIO DB 0 m ( roll) OPTIMA Support 0 pieces ( bucket) VARIO KM/KM Duplex 6.8 m ( roll) This table gives an indication of the materials needed based on a maximum wall height of.6 m and spacing of vertical studs 600 mm center on center. 5

4 I. The Metal Frame The mechanical structure Floor and Ceiling Studs (Item in the illustration on Page 5) The standard elements that make up the frame ensure the system is both economical and mechanically stable. The structure can be adapted to fit virtually every architectural situation, producing a final superbly flat and straight wall surface by absorbing unevenness in the original wall. OPTIMA Ceiling Stud OPTIMA Floor and Ceiling Studs (Pictures & ) allow the embedding and the adjusting of the vertical stud positioning. Intermediate Supports (Item in the illustration on Page 5) OPTIMA Floor Stud The intermediate supports consist of a spacer bar clipped onto a horizontal stud (OTPIMA Support; Picture ) or anchored directly to the wall (OTPIMA Support Reno; Picture ). A polyamide key fastens the insulation material and secures the vertical studs, allowing thickness adjustment with millimeter precision. Facing Support (Item & in the illustration on Page 5) For the facing support, the OPTIMA 0 Stud (a.0 m metal section) can be jointed and adjusted to match the length as required. OPTIMA 0 and 50 Studs can be used to join or link OPTIMA 0 Studs. (Picture 5). OPTIMA 0 a 50 Stud 5 Intermediate Supports OPTIMA 0 Stud Joints between OPTIMA 0 Stud and OPTIMA 0 or 50 Studs must overlap at least 0 cm. With an OTPIMA 0 Stud and an intermediate support fixed at.5 m height, the maximum heights to ceiling are.60 m and.80 m by adding an OPTIMA 0 Stud or OPTIMA 50 Stud respectively. In short The Advantages of the OPTIMA Intermediate Supports. Reduced thermal bridges Easy and quick to install Adjustment possible after installation of insulation material and horizontal studs In short The Advantages of OPTIMA Studs. The clip fastener ensures studs are firmly secured in position and will not shake loose Time saving during installation Adjustment to the nearest millimetre All advantages of the OPTIMA System at a glance on Page 9 All advantages of the OPTIMA System at a glance on Page 9 6 7

5 II. Insulation The thermal and sound layer III. Vapour retarder and air tightness layer The glass wool product has to be installed between the wall and the vertical studs (Item 5 in the illustration on Page 5). As the system guarantees a continuous layer of insulation material thermal bridges are reduced to a minimum. Pipes and electric cables can be integrated without degrading the insulation. To avoid condensation damage in the structure vapour retarder and air tightness layer needs to be installed on the inner facing surface of the insulation layer (= the warm side; Items 6, 7 & 8 in the illustration on Page 5). This barrier prevents water vapour passing from the room into the construction. Using light weight glass wool insulation material, available in a wide range of thicknesses, it is possible to gain optimal thermal resistance with minimum use of space. The material s flexibility and stiffness ensure the cavity is completely filled. VARIO KM & VARIO KM Duplex The intelligent vapour retarder and air tightness membrane Products with the lowest thermal conductivity, λ d = 0.0 W/(mK) or 0.05 W/(mK), are the preferable as they provide maximum thermal performance with minimum loss of room area. In winter, ambient relative humidity outside is lower than inside In summer, ambient relative humidity outside is greater than a building. VARIO KM / KM Duplex closes up to prevent the penetration inside a building. In this case VARIO KM / KM Duplex opens up. of water vapour into the construction (Picture ). In this way any moisture in the construction can move into the interior of the building (Picture ). In short The Advantages of the Insulation Material. High performing thermal and acoustic insulation Compressed products easy to handle and install Improved acoustics, non-combustible In short The Advantages of VARIO KM / KM Duplex. Dual functionality humidity regulation: improved and faster drying out in summer, and secure barrier in winter Reliable functionality with matched components Ease of work: printed guidelines for easy accurate cutting, and fleece surface for better adhesion to substrate All advantages of the OPTIMA System at a glance on Page 9 All advantages of the OPTIMA System at a glance on Page 9 8 9

6 VARIO System Components To ensure minimal energy costs and a comfortable living environment requires not only that a building should be well insulated but also the building envelope is air tight. The breathable active VARIO KM/ KM Duplex membrane represents a new milestone in building technology. The result of its special structure, the polyamide foil boasts a property unique worldwide: In winter when humidity is relatively low, the pores close, preventing interior water vapour penetrating into the construction. In summer, with relatively high humidities, the pores open, allowing any moisture that might have found its way into the structure to dry out. There is no risk of mould formation. IV. Facing The finishing wall The OPTIMA System offers a wide variety of different finishes and ensures high thermal and acoustic comfort in the interior living area. The system can be adapted to meet the tastes of even the most creative interior decorator, with today s numerous types of covering allowing expression of the personal touch. Plaster board, high stiffness, pre-painted, water repellent, or wood panelling, PVC, melamine, solid, perforated, or even simple plywood everything is possible. Whereas, standard foils do not allow drying out, trapping moisture in the construction, VARIO KM/ KM Duplex foil is clearly ideal for creating air tight sealing in wall constructions. Facing with plaster board (Item 9 in the illustration on Page 5) VARIO System, an overview of all components perfectly matched with each other Product Properties Uses Climatic membrane VARIO KM Duplex Reinforced breathable climatic membrane for sealing insulation Excellent protection against moisture, highly layers in walls, with a variable sd-value ranging from 0. 5 m tear-resistant, practical aid for installation Whatever or wherever you want to insulate, Placo plaster board enjoys a number of significant advantages, such as rapid installation, a superbly smooth, even surface that can be adapted to the virtual every type of interior. VARIO KM Breathable climatic membrane sealing for insulating layers in Excellent protection against moisture walls, with a sd-value ranging from 0. 5 m Adhesives and sealing products VARIO DB Sealing tape To ensure air tight junctions between OPTIMA Floor and Ceiling Studs VARIO DS Sealant in a handy cartridge or high yield sausage bag For all joints in VARIO KM/VARIO KM Duplex climatic membranes on components such as walls and floors VARIO Pro Tape Durably elastic and self-adhesive sealant For optimal production of windproof and and airtight joints in VARIO climatic membranes. 50 % quick to use as with a cartridge! VARIO KB Single-sided, extra wide adhesive tape with high bonding force For sealing VARIO KM/VARIO KM Duplex joints airtight VARIO Powerflex Single-sided, expandable and highly flexible adhesive tape Airtight bonding of corners, joints and breakouts In short The Advantages of Plaster Board. Superbly smooth, even surface Rapid installation Can be adapted to all architectural designs (ribbed walls, great height ) All advantages of the OPTIMA System at a glance on Page 9 0

7 OPTIMA System High level thermal performance OPTIMA System Solutions for high energy efficiency houses The following calculations demonstrate thermal insulation performance one can expect using the OPTIMA System with different types of wall construction. When insulating an outer wall, VARIO KM /KM Duplex has to be installed as vapor retarder and airtightness layer. In all the examples cited here, accessory OPTIMA Supports and a standard plaster board (.5 mm) are applied to different types of supporting wall and insulation materials. Supporting wall 6 cm concrete 0 cm hollow concrete blocks 0 cm bricks Facing.5 mm plaster board.5 mm plaster board.5 mm plaster board ISOVER Glass Thickness: 85 mm Thickness: 85 mm Thickness: 85 mm Wool Product R =.65 m.k/w R =.65 m.k/w R =.65 m.k/w λ d = 0.0 W/(mK) λ d = 0.0 W/(mK) λ d = 0.0 W/(mK) U-Value 0. W/(m.K)* 0. W/(m.K)* 0.9 W/(m.K)* Total thickness of system 05 mm** 05 mm** 05 mm** ISOVER Glass Thickness: 00 mm Thickness: 00 mm Thickness: 00 mm Wool Product R =.85 m.k/w R =.85 m.k/w R =.85 m.k/w λ d = 0.05 W/(mK) λ d = 0.05 W/(mK) λ d = 0.05 W/(mK) U-Value 0. W/(m.K)* 0. W/(m.K)* 0.9 W/(m.K)* Total thickness of system 0 mm** 0 mm** 0 mm** ISOVER Glass Thickness: 00 mm Thickness: 00 mm Thickness: 00 mm Wool Product R =.5 m.k/w R =.5 m.k/w R =.5 m.k/w λ d = 0.0 W/(mK) λ d = 0.0 W/(mK) λ d = 0.0 W/(mK) Supporting wall 5 cm cellular concrete (R =.5) Wood frame house*** 0 cm glued bricks (R = 0.7) Facing.5 mm plaster board.5 mm plaster board.5 mm plaster board ISOVER Glass Thickness: 00 mm Thickness: 0 mm Thickness: 00 mm Wool Product R =.5 m.k/w R =.5 m.k/w R =.5 m.k/w λ d = 0.0 W/(mK) λ d = 0.05 W/(mK) λ d = 0.0 W/(mK) + Thickness: 60 mm R =.85 m.k/w λ d = 0.0 W/(mK) U-Value 0.7 W/(m.K)* 0.9 W/(m.K)* 0. W/(m.K)* Total thickness Total construction thickness Total construction thickness Total construction thickness of construction (wall + lining) = 80 mm** (wall + lining) = 0 mm** (wall + lining) = 0 mm** * Calculations were made with TRISCO software, version 0.0w 00 PHYSIBEL, conform with existing standards. ** Air gap of 7.5 mm; the insulation material is compressed flush to the vertical studs. *** The wooden frame is not taken in account for U-value. U-Value 0.8 W/(m.K)* 0.7 W/(m.K)* 0.5 W/(m.K)* Total thickness of system 0 mm** 0 mm** 0 mm** * Calculations were made with TRISCO software, version 0.0w 00 PHYSIBEL, conform with existing standards. **Air gap of 7.5 mm; the insulation material is compressed flush to the vertical studs.

8 OPTIMA System An efficient sound insulation A dry system, easy to install For acoustic comfort indoors, a house needs to be well insulated against the noise outside. The OPTIMA System, based on the mass-spring-mass principle, achieves ISOVER Acoustic Comfort Classes, which generally exceed standard requirements for sound insulation. The OPTIMA System safeguards personal privacy in the home, maintaining the well-being of its occupants. The OPTIMA System is quick and easy to install, clean and dry. In contrast to traditional dry lining solutions, adhesives and glues are not needed, allowing installation in unheated rooms or during periods of frost. A Acoustic insulation of a construction is determined by the (weighted) sound reduction index R w, expressed in db: the higher the R w, the better the sound insulation. The table below shows some examples of sound reduction for different types of support walls, insulation and facing materials. Thickness of ISOVER Support + Support glass wool with Facing Support only OPTIMA Gain AFr 5 kpa.s/m Rw (C;Ctr) in db Rw (C;Ctr) in db Rw+C in db. Installation of OPTIMA Floor and Ceiling Studs The position of the OPTIMA Floor and Ceiling Studs is determined by the width of the window frame (Picture, point T) minus the thickness of the facing. Check the frames reference points to ensure correct positioning of the OPTIMA Floor and Ceiling Studs and correct any possible misalignment. Mechanical Installation according to the support: Pistocelling (ideal for concrete slabs) Plugs to be hammered (screw + plug) B T A C.5 m max Hollow concrete blocks 00 mm + glue Hollow concrete blocks 00 mm + glue Hollow concrete blocks 00 mm + glue Hollow concrete blocks 00 mm + glue Concrete 60 mm 00 mm Wood panelling 5 (- ; -) 7 (- ; -) 5 00 mm PVC panelling 5 (- ; -) 67 (- ; -) 00 mm 75 mm 85 mm.5 mm Plaster board.5 mm Plaster board.5 mm Plaster board 5 (- ; -) 76 (- ; -) 0 5 (- ; -) 68 (- ; -0) 58 (- ; -) 7 (- ; -6) If the ceiling is made of concrete blocks, the upper corners can be attached with expansion plugs. To ensure the joint between the OPTIMA Floor and Ceiling Studs, and the support is air tight VARIO DB band should be used (Picture ). Installation in humid rooms requires the necessary protection for such joints. (A) OPTIMA Floor and Ceiling Studs (B) VARIO DB (C) OPTIMA 0 Stud (horizontal) Hollow bricks 00 mm.5 mm 00 mm + glue Plaster board Hollow bricks 00 mm.5 mm 75 mm + glue Plaster board (0 ; -) 68 (- ; -9) 50 (-5 ; -7) 66 (- ; -8) 8. Installation of OPTIMA 0 Studs and OPTIMA Support Plaster tile 70 mm 85 mm In multi-family buildings.5 mm Plaster board 5 (- ; -) 57 (- ; -6) In new buildings, horizontal OPTIMA 0 Studs are installed a maximum of.5 m from the floor (Picture ). Depending on the facing and on wall geometry intermediate OPTIMA Supports are clipped every 60 cm (Picture ). For renovation work OPTIMA support Reno are fixed directly to the wall. Sound absorbing elements installed on the walls (Picture ) and ceilings can significantly reduce echo in hallways. The OPTIMA System, with a perforated facing is ideal for such situations. 5

9 . Cutting and installing the insulation material 6. Installation of the vapour retarding and air tight layer The insulation material should be cut to the height floor-ceiling plus cm, and installed such that the OPTIMA Supports pierce the material; panels joints should be tight and flush (Picture ). Once the metal studs are securely located, VARIO KM or VARIO KM Duplex can be applied as a vapour retardant, airtight layer. VARIO accessories, such as VARIO DS, an adhesive sealing compound, and VARIO ProTape, an adhesive tape, are used to fix the membrane to the studs, floor and ceiling. The construction is only airtight if VARIO KM/KM Duplex are bonded well to the floor and ceiling. Each membrane seam should overlap by a least 0 cm (Picture ).. Installing the keys of OPTIMA Supports Locate the key on the projecting end of the OPTIMA Support or OPTIMA Support Reno supports (Picture point F). Applying single-sided VARIO KB tape to all membrane seams ensures a reliable, tight seal. Overlapping the seams by at least 0 cm, and the tape s powerful bonding strength avoids leaks in the system (Picture ). F 5. Installing the vertical studs Insert the OPTIMA 0 Stud in the OPTIMA Floor Stud (Picture ). Depending on the height required, affix either an OPTIMA 0 or 50 Stud and slide the extended stud into position in the OPTIMA Ceiling Stud from the side. As it is elastic and highly flexible, VARIO Powerflex is ideal for taping up corners and breakouts (Picture ). Vertical studs are locked in position by the keys of OPTIMA Support or OPTIMA Support Reno pieces, first making sure studs are vertical using a spirit level (Picture ). 7. Cutting and fixing the facing The facing material should be cut to a length of the floor to ceiling height minus cm. Hold the board flush to the ceiling and screw it directly to the studs (Picture ), at 0 cm intervals, leaving a minimum of cm perimeter from the edge of the board. 6 7

10 Dealing with specific issues Integrating ducts Standard electrical appliances, home automation and multimedia have led to an increasing in cabling and ducting that need to be included in buildings (Picture ). The OPTIMA System allows the integration of such networks in the lining without compromising insulation. They are run between ISOVER glass wool and plaster boards. VARIO Powerflex is used to ensure breakout points are both vapour and air tight. OPTIMA System Advantage after advantage Renovating with the OPTIMA System means rapid installation of an airtight insulation layer including a finished wall. No waiting for the lengthy drying times of individual components is necessary. The OPTIMA System allows the integration of cables and ducts without compromising the insulation. All elements of the OPTIMA System are easy to transport, store and distribute on site. With ISOVER glass wool products, up to 00 mm thick, a significant improvement of the thermal insulation and a reduction of energy costs can be achieved. Furthermore, this solution improves sound properties of interior rooms and protects against noise outside the building. OPTIMA Metal frame light, solid, but elastic The OPTIMA Connector This accessory is used to construct T-joints between OPTIMA transverse and perpendicular studs, for instance to accommodate a window frame (Picture ). Inner and outer corners An OPTIMA Floor and Ceiling Stud can replace studs at the corners (Picture ). Avoids thermal bridges, as the insulation layer is continuous Maintains perfectly the studs thanks to a clip effect preventing any vibrations Easy and practical installation with no waste Precise installation to the nearest millimetre Perfectly matched components ISOVER insulation highest insulation performance Embrasure The position of the windows has to be taken into account. If it is in the inner surface of the wall, the length of OPTIMA Supports are chosen according to the depth of the embrasure. Products with the lowest thermal conductivity λ d = 0.0 W/(mK), or λ d = 0.05 W/(mK) save space and increase thermal and sound insulation performance Compressed products save space and time, both for transport and distribution on site Excellent quality and safety non-flammable and CE mark certified OPTIMA Support Lining Thickness Length of embrasure (finished with standard (Picture point T) plasterboard BA ) 75 from 9 mm to mm 00 mm 00 from mm to mm 0 mm 5 from mm to 5 mm 0 mm Humid rooms In humid rooms (bathroom, garage, non-heated basement), plaster board facings have to be waterrepellent. Irrespective of whether the floor is rough or finished, an impregnated foam strip needs to be installed as a central joint (Picture 5 point A) between the bottom wall plate and floor. Installations on rough floors require additional protection in the form of a polyethylene foil overlapping the floor by at least cm (Picture 5 point B). T 5 VARIO air tightness and protection against moisture Breathable and moisture regulatory Excellent assurance due to a variable sd-value of m Ease of work: printed guidelines for easy accurate cutting, and fleece surface for better adhesion to substrate Product perfectly matches for every application Patented system based on 0 years experience and more than 5 million m of protected area installed Facing with plaster board suitable for every design Quick assembly Smooth and level surface Suitable for every room height or size 8 9

11 OPTIMA System A complete range ISOVER Insulation Material The Accesories ISOVER Glass Wool Product with λ d = 0,05 W/(mK) R Thickness Length Width m.k/w (mm) (m) (m) m /packet packet/pallet m /pallet OPTIMA Floor and Ceiling Studs OPTIMA Floor and Ceiling Studs allow the embedding and the adjusting the vertical stud position. OPTIMA Stud Pallet of bundles Length: 5 cm of 0 units = 56 m OPTIMA 0 Stud Metal stud of.0 m allowing the splicing and length adjustment. ISOVER Glass Wool Product with λ d = 0,0 W/(mK) OPTIMA 0 Stud Length: 0 cm Pallet of 0 bundles of 0 units = 960 m R Thickness Length Width m.k/w (mm) (m) (m) m /packet packet/pallet m /pallet Couplene OPTIMA 0 and 50 Stud Short metal stud designed for linking or lengthening the OPITMA 0 Studs. OPTIMA 0 Stud Pallet of 0 bundles Length: 0 cm of 0 units = 0 m OPTIMA 50 Stud Pallet of 0 bundles Length: 50 cm of 0 units = 00 m Double edge knife for cutting the insulation material. OTPIMA Support A support pillar that has to be clipped onto a metal stud, with a plastic key. OPTIMA Support 75 OPTIMA Support 00 OPTIMA Support 5 50 pieces 50 pieces 50 pieces 0

12 The Accesories OPTIMA Support Reno A support pillar that can be attached directly to the wall, with plastic key. OPTIMA 0 pieces Support Reno VARIO DB Roll of sealing tape to ensure airtight junctions between OPTIMA Floor and Ceiling Studs and their support wall. Length - Width 8 m 7 mm 6 rolls = 8 m OPTIMA Connector For joining OPTIMA 0 Studs at particular points. OPTIMA Connector 5 pieces VARIO DS Sealant in a handy cartridge or high yield sausage bag. For all air tight joints in VARIO KM / KM Duplex on components such as floors, ceilings and walls. Length - Width 0 m 5 mm 5 rolls = 50 m VARIO KM Duplex Reinforced breathable climatic membrane for sealing insulation layers in walls, with a variable sd-value ranging from 0. 5 m, strengthen with special fleece and practical aid for install. Length - Width 0 m.5 m 60 m / roll VARIO KM Breathable climatic membrane sealing for insulating layers in walls, with an sd-value ranging from 0. 5 m. Length - Width 60 m m 0 m / roll 0 m m 60 m / roll 5 m m 0 m / roll VARIO Pro Tape Durably elastic and self-adhesive sealant for fixing the VARIO KM / KM Duplex on metal studs and for air tight joints on floor, ceiling and wall. Length - Width 0 m 5 mm 5 rolls = 50 m VARIO KB Single-sided, extra wide adhesive tape for joining the seams of VARIO KM / KM Duplex at vapour retarder and air tight membranes. 0 m 60 mm rolls = 0 m 0 m 60 mm 5 rolls = 00 m VARIO Powerflex Single-sided, expandable and highly flexible adhesive tape for joining the seams of VARIO KM / KM Duplex at vapour retarder and air tight membranes at specific spots (corners, joints, breakouts ). Length - Width 5 m 60 mm 0 rolls = 50 m

13 Saint-Gobain Insulation Les Miroirs 9096 La Défense Cedex France

OPTIMA Dry Lining System. High Performing, Easy & Quick INSTALLER GUIDE

OPTIMA Dry Lining System. High Performing, Easy & Quick INSTALLER GUIDE OPTIMA Dry Lining System High Performing, Easy & Quick INSTALLER GUIDE Floor Measure distance out from wall thickness of the insulation being used + 20mm Use chalk line to mark out line for floor U-channel

More information

PITCHED ROOF SOLUTIONS

PITCHED ROOF SOLUTIONS PITCHED ROOF SOLUTIONS, airtightness and moisture management solutions for pitched roof rafter applications. isover.co.uk Pitched Roof Solutions Building extra living space within the attic is a great

More information

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products. GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent

More information

Vario XtraSafe. Airtightness and moisture management system.

Vario XtraSafe. Airtightness and moisture management system. Vario XtraSafe Airtightness and moisture management system. Airtightness The Importance of Airtightness Nothing protects the homes you create like Vario XtraSafe Vario XtraSafe is the next generation of

More information

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6 DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00

More information

GypLyner (walls) Metal framed wall lining system. GypLyner.

GypLyner (walls) Metal framed wall lining system. GypLyner. GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal

More information

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide systems provide simple and effective techniques for fixing Gyproc plasterboards or Gyproc thermal laminates to brick, block, and concrete walls. They can be used in all building types in both new-build

More information

Contents P/ 3. Ensuring Optimal Results P/ 4. Roof Insulation SF40 P/ 5. Roof Insulation Over Rafter Application P/ 6

Contents P/ 3. Ensuring Optimal Results P/ 4. Roof Insulation SF40 P/ 5. Roof Insulation Over Rafter Application P/ 6 Installation Guide Contents P/ 3 Ensuring Optimal Results P/ 4 Roof Insulation SF40 P/ 5 Roof Insulation Over Rafter Application P/ 6 Roof Insulation Under Rafter Application P/ 7 Roof Insulation Duet

More information

1. What are the benefits of Decorative Wall Panels? 2. Where can these decorative panels are used? 3. Are the panels waterproof?

1. What are the benefits of Decorative Wall Panels? 2. Where can these decorative panels are used? 3. Are the panels waterproof? 1. What are the benefits of Decorative Wall Panels? Decorative Wall Panels are made from precision extruded PVC and decorated with unique designs ranging from marble, onyx to wood grain patterns. Other

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00 Cadbury

More information

The Revolutionary New Plasterboard TIMBER FRAME GUIDE

The Revolutionary New Plasterboard TIMBER FRAME GUIDE The Revolutionary New Plasterboard TIMBER FRAME GUIDE 2 HABITO BOARD is a stronger plasterboard that provides enhanced sound insulation, extra durability and for the first time, direct fixing capability.

More information

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior C e r t a i n Te e d The SMART Vapor Retarder & Air Barrier Film Air Barrier Installation Instructions for Wood Framing In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor

More information

Experience Gained over a period of 25 years, from a single production line to a plant employing over 150 people.

Experience Gained over a period of 25 years, from a single production line to a plant employing over 150 people. CHEMISTRY BETWEEN US AIB is the pioneer in modern solutions in the construction industry. We started our company in 1992, focusing on the production of innovative finishing and insulation materials. Quality

More information

Product Information Sheet

Product Information Sheet Product Information Sheet Product Name ISOVER Metac - high performance insulation Metac G3 Touch is a high performance low lambda mineral wool insulation roll with both excellent thermal and acoustic properties.

More information

INTERNAL PARTITION PANEL ASSEMBLY

INTERNAL PARTITION PANEL ASSEMBLY Cost-effective and sustainable Bio-Renewable Indoor Materials with high potential customization and creative design in Energy Efficient buildings INTERNAL PARTITION PANEL ASSEMBLY www.brimee.eu DESCRIPTION

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

Vario XtraSafe. Airtightness and moisture management system.

Vario XtraSafe. Airtightness and moisture management system. Vario XtraSafe Airtightness and moisture management system. Airtightness Nothing protects the homes you create like Vario XtraSafe Vario XtraSafe helps you achieve a high level of airtightness and meet

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system C0 Partitions Staggered stud acoustic partition system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a non-loadbearing stud partition incorporating a single framework

More information

SMARTPLY PROPASSIV - AIRTIGHT OSB

SMARTPLY PROPASSIV - AIRTIGHT OSB SMARTPLY PROPASSIV - AIRTIGHT OSB Taped panel assembly tested beyond 2000 Pa of positive and negative air pressure - Fraunhofer Institute of Building Physics SMARTPLY PROPASSIV is a Passive House Institute

More information

TREAT RISING DAMP AND REDECORATE IN UNDER 24HRS

TREAT RISING DAMP AND REDECORATE IN UNDER 24HRS APPLICATION GUIDELINES SYS TEM TREAT RISING DAMP AND REDECORATE IN UNDER 24HRS FAST, HIGH PERFORMANCE RISING DAMP TREATMENT & REPLASTERING SOLUTION. COMPLETE A TREATMENT & REDECORATE WITHIN 24HRS. PRODUCT

More information

RADON ABATEMENT FROM THE GROUND UP

RADON ABATEMENT FROM THE GROUND UP RADON ABATEMENT FROM THE GROUND UP The solution for a dry, comfortable, and durable basement! CLOSED-CELL 2018 Demilec, 3315 E. Division St., Arlington, TX 76011 Phone: 817.640.4900 Fax: 817.633.2000 Info@Demilec.com

More information

Ventura Office Partitions. Technical guide

Ventura Office Partitions. Technical guide Office Partitions Technical guide - General Despite its minimalistic and sleek design, is a genuine, relocatable office partition in line with other products in the Triplan system. This relocatable office

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system

More information

Sheet Metal Protective Films

Sheet Metal Protective Films Sheet Metal Protective Films Protective films manufactured by R-FOLL based on an adhesive polyethylene film are designed for protecting surfaces from mechanical and chemical damage. Our films form a temporal

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

The extra strong, extra durable, sound resistant system that you can direct fix to

The extra strong, extra durable, sound resistant system that you can direct fix to C0 Partitions The extra strong, extra durable, sound resistant system that you can direct fix to All our systems are covered by SpecSure when using genuine Gyproc and Isover products gyproc.ie Utilising

More information

Container Installation Guide

Container Installation Guide Container Insulation Container Installation Guide Panels and Inserts The InSoFast CX Container panel and the Inserts are designed to fit most shipping containers. Containers have three types of corrugations:

More information

Independent twin frame high performance acoustic separating wall system

Independent twin frame high performance acoustic separating wall system C04 Partitions Independent twin frame high performance acoustic separating wall system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a lightweight, non-loadbearing

More information

Concrete Soffit Direct Fix

Concrete Soffit Direct Fix Installation Guide Concrete Soffit Direct Fix Recommended Pattern insulation boards may be installed in any pattern. The recommended pattern is a square-set pattern, for simplest and quickest configuration

More information

Container Installation Guide

Container Installation Guide Continuous Insulation Container Installation Guide Panels and InSerts The InSoFast CX Container panel and the InSerts are designed to fit most shipping containers. Containers have three types of corrugations:

More information

GLASS FIBRE MESH FABRICS. Stronger ideas for a sustainable world ETICS. Marble slab reinforcement. Lightweight construction boards reinforcement

GLASS FIBRE MESH FABRICS. Stronger ideas for a sustainable world ETICS. Marble slab reinforcement. Lightweight construction boards reinforcement GLASS FIBRE MESH FABRICS Marble slab reinforcement ETICS Mosaic reinforcement Lightweight construction boards reinforcement Profile manufacture Render reinforcement Floor heating mats Stronger ideas for

More information

Optima Dry Lining System

Optima Dry Lining System Optima Dry Lining System High Performing, Easy & Quick 1ST NSAI CERTIFIED Dry Lining System in Ireland SpecHub ISOVER SpecHub REGISTER TODAY! The home of free residential and commercial insulation, airtightness

More information

EXP. Tilux-Line 4-6 DURABASE WP 7. Tilux Quick finder 11

EXP. Tilux-Line 4-6 DURABASE WP 7. Tilux Quick finder 11 EXP TILUX-LINE Linear drainage Level-access shower boards TILUX Point drainage Tilux-Line 4-6 DURABASE WP 7 Tilux 8-10 Quick finder 11 Tilux-Line Linear drainage Tileable shower boards Tilux Point drainage

More information

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels Glasboard Liners installation details Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION These guidelines are provided

More information

The insulating panel for energy conscious interior renovation. The product. Safe, noticeably better Proved a million times.

The insulating panel for energy conscious interior renovation. The product. Safe, noticeably better Proved a million times. The product Safe, noticeably better Proved a million times The insulating panel for energy conscious interior renovation. Necessary tools: Tips for saving heating costs The heating cost shock due to the

More information

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION: OWENS CORNING PRODUCTS What exactly is an insulating system? The answer starts with the role insulation plays in your home. All insulating products are based on a single basic principle: heat moves from

More information

Insulation boards PhoneStar

Insulation boards PhoneStar Sound Insulation Bavaria Insulation boards PhoneStar Installation instructions Wall Version 15.05. 2015 ONE solution universal in every area PhoneStar is an innovative, very efficient insulation board

More information

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

Parabond 600 Elastic adhesive sealant with high initial bonding strength. Parabond 600 Elastic adhesive sealant with high initial bonding strength. Product: Parabond 600 is an MS-polymer based, durable and fast curing elastic adhesive. Applications: Parabond 600 has a very high

More information

Installation instructions Thin, flexible multi-foil insulation

Installation instructions Thin, flexible multi-foil insulation The original BBA certified multi-foil Installation instructions Thin, flexible multi-foil insulation Below rafter 0.18 solutions Below 100 rafter + 70 foiled 70 foiled 165.5 spacer batten min 10 38 batten

More information

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION DRAINAGE SOLUTIONS SINCE 1908 PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION PROVEN PERFORMANCE ARMTEC.COM

More information

Sheathing Board Xtra protection, built in.

Sheathing Board Xtra protection, built in. Sheathing Board Xtra protection, built in. Introducing Glasroc X Sheathing Board Glasroc X is a high performance sheathing board which provides up to 6 months weather protection as certified by the British

More information

Specifications for Insulation Board wall and ceiling applications

Specifications for Insulation Board wall and ceiling applications Specifications for Insulation Board wall and ceiling applications Product Ref: Marmox Multiboard 600mm wide, 1250/2500mm long. 10, 12.5, 20, 30, 40, 50, 60mm thick. Also known as Marmox Board- Pro and

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

GIP-TEK TM PLASTERBOARD PRODUCT GUIDE

GIP-TEK TM PLASTERBOARD PRODUCT GUIDE OCTOBER 2015 TECHNICAL BROCHURE GIP-TEK TM PLASTERBOARD PRODUCT GUIDE www.gip-tek.com.au GIP-TEK TM PLASTERBOARD PRODUCT GUIDE CONTENTS PAGE 03. GECA PAGE 04. GIP-TEK Wall PAGE 05. GIP-TEK Curve PAGE 06.

More information

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM FOCAL POINT RENDAPANEL TM CLADDING SYSTEM strength and durability SYSTEM INFORMATION & TECHNICAL SPECIFICATION V4 2002 Page 1 of 7 INTRODUCTION Monolithic Light Weight Cement Render Cladding RendaPanel

More information

A. Source Limitations: Obtain each type of building insulation through one source.

A. Source Limitations: Obtain each type of building insulation through one source. SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Expanded AmDry Installation Guide

Expanded AmDry Installation Guide Expanded Tools Required: Tape measure Utility Knife Straight edge Rubber mallet Circular saw with plywood blade Pull or pry bar 1/2 spacers Pencil / marker Tapping block (made from a piece of 2 x 4 ) Getting

More information

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components. 84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes 90 System Components installation/ SYSTEM COMPONENTS INSTALLATION ADVICE LAPPING and JOINTING

More information

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

Parabond 600 Elastic adhesive sealant with high initial bonding strength. Parabond 600 Elastic adhesive sealant with high initial bonding strength. Product: Parabond 600 is an MS-polymer based, durable and fast curing elastic adhesive. Applications: Parabond 600 has a very high

More information

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE Certificate No C-9432-13 Issued February 12, 2013 Updated July 20, 2018 PRODUCT CERTIFICATE NAME OF PRODUCT HYBRIS MANUFACTURER ACTIS SA 30 Avenue de Catalogne 11300 Limoux France PRODUCT DESCRIPTION HYBRIS

More information

Schluter -KERDI-DRAIN

Schluter -KERDI-DRAIN Schluter -RONDEC Finishing and edge-protection profile with a rounded reveal surface. Schluter -RONDEC is a finishing and edge-protection profile for tiled edges and outside corners of tiled surfaces.

More information

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING:

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING: GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 is a reflective insulation composed of the reinforced aluminum facers on a Polyethylene foam core. ESD 5 can be installed in Roof assemblies, Floors and walls.

More information

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING:

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING: GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 is a reflective insulation composed of the reinforced aluminum facers on a Polyethylene foam core. ESD 5 can be installed in Roof assemblies, Floors and walls.

More information

Sealing and decoupling. Things to know and technology

Sealing and decoupling. Things to know and technology Sealing and decoupling Things to know and technology GB wedi products and systems are of a high standard of quality and have received numerous certifications throughout Europe. 2 Contents Contents Page

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

WE International, Inc.

WE International, Inc. M E E T Y O U R R O U N D T H E Steel Frame Building Roof Application - Drape Method Ideal insulation for steel frame building application Quick and easy to install Provides reflective insulation for radiant

More information

Thermal insulated roofing SYSTEM

Thermal insulated roofing SYSTEM Thermal insulated roofing SYSTEM VENTILATED, LIGHTWEIGHT AND INSULATED ROOF The brand new Tejas Borja SARKING SYSTEM is a complete solution for external insulated pitched roofs, designed for use both in

More information

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of

More information

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only Installation Method (Existing Walls) 1. ESP Low-E Housewrap is installed over exterior wall sheathing, make sure reflective side faces out: foil flange faces down. 2. Determine width of ESP Low-E HouseWrap

More information

INSULATING CONCRETE FORMWORK SYSTEM

INSULATING CONCRETE FORMWORK SYSTEM Cl/SfB (21) Gn7+Eq4 November 2004 BecoWallform INSULATING CONCRETE FORMWORK SYSTEM A modern building system which provides extra performance to satisfy current and future building standards Structure and

More information

4. Insulation of external walls

4. Insulation of external walls 4. Insulation of external walls 4.1. Insulation on the internal side of the walls For both internal and external types of insulation the major advantages are the decrease in energy consumption as well

More information

NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. Date of update May 30, 2018 Valid until May 29, 2023 HYBRIS

NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. Date of update May 30, 2018 Valid until May 29, 2023 HYBRIS NAME OF PRODUCT HYBRIS MANUFACTURER ACTIS SA 30 Avenue de Catalogne 11300 Limoux France CERTIFICATE VTT-C-9432-13 Date of update May 30, 2018 Valid until May 29, 2023 PRODUCT DESCRIPTION HYBRIS is a flexible,

More information

C07. S04. P02 P10 GypLyner universal

C07. S04. P02 P10 GypLyner universal ! This section includes updated information, added since it was first published in December 05. Last updated 4/06/07. S04. P0 P0 GypLyner universal Including. S0. P0 P04 Linings introduction Linings Introduction

More information

The brighter way to insulate

The brighter way to insulate The brighter way to insulate 1200 multi-foil that does what it says Installation instructions The multi-foil system certified to achieve 0.2 when installed according to BBA certificate No 06/4379 100 rafter

More information

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls Built-up Metal Walls Built-up metal walls Built-up metal wall design Thermal insulation Built-up metal walls can be installed on all types of residential and non-residential buildings, although they are

More information

ROCKWOOL FLEXI Insulation Application Guide

ROCKWOOL FLEXI Insulation Application Guide ROCKWOOL FLEXI Insulation Application Guide Pitched roof Rafters Intermediate Floors Internal Partitions Separating Floors Separating Walls ROCKWOOL FLEXI One product, many applications Choosing ROCKWOOL

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

Technical data sheet StoSilent Board 100

Technical data sheet StoSilent Board 100 Acoustic panel made of expanded glass granulate for suspended ceiling and wall structures Characteristics Areas of application interior for suspended ceiling and wall structures fixing with screws, bonded

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:

More information

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness, Wall Linings Our versatile range of wall lining systems makes it easy to produce a high-quality, high-performance finished wall regardless of the background. Whether your priority is acoustic control,

More information

Selecting floors and ceilings

Selecting floors and ceilings floors and ceilings email: bgtechnical.enquiries@bpb.com www.british-gypsum.com/health 89 floors and ceilings Introduction 9 Solutions - key systems 9 Solutions for concrete floors 9 - Dense slab 9 This

More information

SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS

SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS PART 1 GENERAL 1.1 RELATED WORK SPECIFIED IN OTHER SECTIONS 1.2 DESCRIPTION OF SYSTEM A. GENERAL:

More information

C08. S04. P02 P08 Tiling

C08. S04. P02 P08 Tiling ! This section includes updated information, added since it was first published in December 2015. Last updated 29/03/2018 C08. S04. P02 P08 Including C08. S01. P02 Finishes introduction C08 Finishes Introduction

More information

POLTERM MAX PLUS. Non combustible stone wool insulation for ventilated rainscreen cladding and overcladding systems. isover.co.uk

POLTERM MAX PLUS. Non combustible stone wool insulation for ventilated rainscreen cladding and overcladding systems. isover.co.uk POLTERM MAX PLUS Non combustible stone wool insulation for ventilated rainscreen cladding and overcladding systems isover.co.uk Polterm Max Plus Non-combustible stone wool insulation Isover Polterm Max

More information

Please Note: PhoneStar was previously branded as Phonewell

Please Note: PhoneStar was previously branded as Phonewell Soundproofing Floors Timber Joist or Concrete Floors Installation Instructions Acoustic Insulation Please Note: was previously branded as Phonewell There are two options to achieve noise reduction through

More information

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

August 2008: Issue 1. Non - Residential New Build 4.5 Basements Non - Residential New Build 4.5 Basements August 2008: Issue 1 Non-residential new build 4.0 Non-residential New Build Basements Contents Introduction find online page Solution optimiser and pathfinder

More information

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components. 84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components installation/ SYSTEM COMPONENTS INSTALLATION ADVICE LAPPING and JOINTING

More information

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of

More information

The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE

The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE Introduction Glasroc X is a high performance building board with a gypsum core containing special additives

More information

TIMBER FRAME HOUSING SOLUTIONS

TIMBER FRAME HOUSING SOLUTIONS TIMBER FRAME HOUSING SOLUTIONS Complete range of acoustic and thermal insulation for timber frame housing isover.co.uk Introduction The timber frame market continues to grow within the UK. Key drivers

More information

Duct Wrap Flexible Wraps

Duct Wrap Flexible Wraps Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone

More information

Refurbishment site guidance for solid-walled houses ground floors

Refurbishment site guidance for solid-walled houses ground floors GOOD PRACTICE GUIDE 294 Refurbishment site guidance for solid-walled houses ground floors What energy savings to aim for Key points to consider Energy savings and SAP ratings Environmental considerations

More information

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide GypWall TM ROBUST GypWall ROBUST is a high impact resistant partition system for use where a more durable structure is required. The system provides a lightweight, cost-effective, non-loadbearing partition

More information

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation Recommended Design Considerations and Guide Specifications For Commercial Building Insulation Date of Issue: October 1, 2004 Recommended Design Considerations and Guide Specifications For Commercial Building

More information

RhinoBond Induction Fixing System

RhinoBond Induction Fixing System RhinoBond Induction Fixing System INSTALLATION INSTRUCTIONS www.hertalan.co.uk 1. Introduction These installation instructions offer Roofers and Contractors information about the material technology involved

More information

Contact Adhesive, Adhesive Paste

Contact Adhesive, Adhesive Paste PU Foams Fire-resistant Silicone Neutral Silicone Bitumen-based Sealant Polyurethane Sealant Contact Adhesive, Adhesive Paste Primer PE Tape, Round PE Profile EPDM Membranes, Butyl Foils Impregnated Window

More information

Exterior Wall Solutions Building Shell

Exterior Wall Solutions Building Shell A strong, water tight and thermally insulated building shell will ensure the buildings sustainability of usage over time. The Exterior Shell is the most important factor of protection to ensure that the

More information

The only insulating and non-combustible membrane!

The only insulating and non-combustible membrane! ROOF AND FACADE APPLICATIONS The only insulating and non-combustible membrane! Innovation for performance and comfort! Roof underlay compliant with EN 13859-1. Rain screen compliant with EN 13859-2. 2016

More information

stretchceilings.com.au

stretchceilings.com.au innovative walls and ceilings stretchceilings.com.au with sound absorption qualities Acoustic for sound absorption qualities ALYOS Acoustic product is perfect for the acoustic correction of sound within

More information

BIG DISCOUNTS AVAILABLE ON SEMPATAP

BIG DISCOUNTS AVAILABLE ON SEMPATAP DIY Warmer Walls BIG DISCOUNTS AVAILABLE ON SEMPATAP THERMAL INSULATION What s it all about? The DIY Warmer Walls Scheme is a discount initiative for Local Authorities to help and encourage householders

More information

CALL TO TALK TO THE SAS TEAM

CALL TO TALK TO THE SAS TEAM CALL 01647 24620 TO TALK TO THE SAS TEAM new EIFS.indd 1 1 8/29/2013 11:21:00 AM Contents Insulation overview Page 4 ProRend EIFS Adhesive System Installation Page 6 ProRend EIFS Rail System Installation

More information

Real Brick Cladding. Iso Klink Pur. Brick Panel System Catalogue

Real Brick Cladding. Iso Klink Pur. Brick Panel System Catalogue Iso Klink Pur Brick Panel System Catalogue 1 BRICK CLADDING PANEL SYSTEM Combination of high performance pur insulation and brick cladding, creating durable and aesthetic system which is quick and easy

More information

Parabond 600 Elastic glue and adhesive with extremely high initial bonding

Parabond 600 Elastic glue and adhesive with extremely high initial bonding Parabond 600 Elastic glue and adhesive with extremely high initial bonding Product: Parabond 600 is a high-quality, quickly drying, durable MS-Polymer based elastic glue and adhesive with a very high initial

More information

Installation and Planning Guide

Installation and Planning Guide Installation and Planning Guide www.dricore.com help@dricore.com or call 1-866-976-6374 Weekdays 9am-5pm EST CONTENTS Why DRIcore... 1 How To Use This Guide... 1 Before You Begin Checklist... 2 Important

More information

Non-combustible internal insulation!

Non-combustible internal insulation! Non-combustible internal insulation! Innovation for performance and comfort! Warmeisolation NICHTBRENNBAR (A1) Wärmeleitfähigkeit (λ) : 0.028 W/mK TECHNISCHER SUPPORT +33 (0)2 96 78 24 22 Thermisch isolerend

More information

Light steel frame walls

Light steel frame walls Light Steel Frame Walls Light steel frame walls Solution optimiser and pathfinder Overview Light steel framing is extensively used due to its good thermal and structural behaviour. Heat loss reduction

More information