We Have a Better Way to Keep You Safe and Comfortable. ENERTITE Open-Cell Spray Polyurethane Foam Insulation

Size: px
Start display at page:

Download "We Have a Better Way to Keep You Safe and Comfortable. ENERTITE Open-Cell Spray Polyurethane Foam Insulation"

Transcription

1 We Have a Better Way to Keep You Safe and Comfortable ENERTITE Open-Cell Spray Polyurethane Foam Insulation

2 ENERTITE is low-density open-cell spray-applied polyurethane foam (SPF) insulation. Applied as a liquid, this water-blown foam quickly expands to many times its original size completely filling wall cavities. ENERTITE easily flows in and around difficult-to-reach areas such as pipes and wiring, creating a seamless seal. In a one-step application, ENERTITE insulates against extreme outdoor temperatures, makes a quieter home, and reduces air leaks. A home insulated with ENERTITE is one that requires less energy for heating and cooling. Feature ENERTITE Open-cell Spray Polyurethane Foam FIBER GLASS BLOWN CELLULOSE Per inch R-value* Air Impermeable Yes at 3.5 thickness No No Seamless Construction Yes No No Fully Adheres Yes No No Long Service Life Yes No No Fills Difficult Spaces Yes No No Superior Sound Control Yes Yes Yes * The R-value of this insulation. R means resistance to heat flow. The higher the R-value, the greater the insulating power. Compare insulation R-values before you buy. There are other factors to consider. The amount of insulation will depend upon the climate, the type and size of your house, and the fuel use patterns and family size. If you buy too much insulation it will cost you more than what you will save on fuel. To achieve proper R-values, it is essential that this insulation be installed properly. This brochure complies with the Federal Trade Commission labeling and advertising of home insulation rules and regulations, Federal Register, 16 CFR Part 460 Labeling and Advertising of Home Insulation: Trade Regulation Rule; Final Rule, Tuesday, May 31, Air Sealing Fact Sheet, 2 The American Lung Association recommends that houses be built airtight to improve indoor air quality.

3 BA JOIS KN WAL INTER PARTIT Improved comfort with reduced drafts Outstanding air sealing 1 Better indoor air quality 2 ATTICS* WALLS We don t make your home, we help make your home better.

4 To learn more about the importance of stopping uncontrolled air leakage, visit ND TS EE LS IOR IONS AROUND WINDOWS AND DOORS* * Not shown: vapor retarders, thermal barriers (e.g. drywall) and ignition barriers as required by your local Building Code.

5 Raising performance to new heights Stop Air Leakage Improve Indoor Air Quality Resist Mold Save Energy Seal Against Pests & Allergens Control Noise Raising Performance To New Heights is a registered trademark of BASF Canada. ENERTITE is a registered trademark of BASF Corporation. ENERGY STAR is a registered trademark of the Environmental Protection Agency BASF Corporation FOAM BASF Corporation 1703 Crosspoint Avenue Houston, TX Fax: spfinfo@basf.com

6 Source: All of Alaska is in Zone 7 except for the following boroughs which are in Zone 8: Bethel, Dellingham, Fairbanks N. Star, Nome, North Slope, Northwest Arctic, Southest Fairbanks, Wade Hampton, Yukon-Koyukuk 2 Zone 1 includes Hawaii, Guam, Puerto Rico, and the Virgin Islands 1 Additional location and climate zone chart detail: Typical house based on prototype house from DOE s report An Estimate of Residential Energy Savings... comparing IECC 2012 to IECC 2006: Single-family, 2-story, 2,400 square foot home with 3 bedrooms Upgrade comparison used ENERTITE SPF to full stud assembly (3.5" or 5.5" dependant on construction style or code R-value requirement) and 6" of ENERTITE SPF in attic along with balance of R-value from blown fiberglass OR to full R-value on unvented roof deck. Air infiltration rate estimates from previous blower door documentation in the range of 1.25 to 1.75 ACH 50, reduced from the average of a 7 ACH rate for the prototype house. As with any airtight construction approach, and to meet IECC code compliance, mechanical ventilation should be provided for proper management of indoor air quality and air exchanges.

7 Heating & Cooling Savings Examples Monthly Savings & Net Positive Cash Flow Location Climate Zone Phoenix, AZ CZ 2 Houston, TX CZ 2 Charlotte, NC CZ 3 Minneapolis, MN CZ 6 Hartford, CT CZ 5 Analysis Case using ENERTITE in the baseline IECC ¹ energy Code vs Energy Code vs Energy Code vs Energy Code vs Energy Code vs Energy Code HERS² Index Improvement HVAC Tonnage Decrease Total Heating and Cooling Cost Savings 18% 24% 15% 37% 33% Annual Savings $213 $255 $159 $565 $571 Monthly Energy Savings $17.75 $21.25 $13.25 $47.08 $47.58 Net Positive Monthly Cash Flow (after mortgage with additional cost of SPF) $14.21 $15.03 $10.00 $31.52 $29.25 The chart above contains analysis of homes in various climate regions of the U.S. using ENERTITE spray polyurethane foam as an alternative to a fiberglass insulation product to meet the minimum code R-value requirements for the applicable code in that region. The analysis not only contains an estimate of heating and cooling cost savings, but also shows the improvements in the HERS rating for the home, as well as savings that may be possible in HVAC sizing. This results in a net positive monthly cash flow for anyone who invests in ENERTITE open-cell spray polyurethane foam from BASF when building their new home. Start putting money in your pocket from the minute you move in! Very few new home options today actually PAY YOU to choose them! ¹ IECC (International Energy Conservation Code) is a registered trademark of the International Code Council (ICC). ² HERS stands for Home Energy Rating System. A HERS Index is a scoring system established by the Residential Energy Services Network (RESNET).

MEMBRAIN. Continuous Air Barrier & Smart Vapor Retarder

MEMBRAIN. Continuous Air Barrier & Smart Vapor Retarder MEMBRAIN Continuous Air Barrier & Smart Vapor Retarder Advanced technology to create a better performing home This patented, revolutionary solution can provide a continuous air barrier along with advanced

More information

26 May 2011

26 May 2011 2 May 2011 www.professionalroofing.net Complications with cathedral ceilings Guidelines for minimizing ice dams with cathedral ceilings by Joan P. Crowe, AIA Homeowners and designers often desire cathedral

More information

INSIDE WHY SPRAY POLYURETHANE FOAM INSULATION?

INSIDE WHY SPRAY POLYURETHANE FOAM INSULATION? INSIDE WHY SPRAY POLYURETHANE FOAM INSULATION? SUSTAIN THROUGH KNOWLEDGE BOOK 1: WHY SPRAY POLYURETHANE FOAM INSULATION BOOK 2: SPF & THERMAL BARRIER SPF & SAFETY PERSONAL PROTECTIVE EQUIPMENT BOOK 3:

More information

VAPOR PERMEABLE VERSUS IMPERMEABLE AIR AND WATER- RESISTIVE BARRIER MEMBRANES IN NORTH AMERICAN WALL ASSEMBLIES

VAPOR PERMEABLE VERSUS IMPERMEABLE AIR AND WATER- RESISTIVE BARRIER MEMBRANES IN NORTH AMERICAN WALL ASSEMBLIES VAPOR PERMEABLE VERSUS IMPERMEABLE AIR AND WATER- RESISTIVE BARRIER MEMBRANES IN NORTH AMERICAN WALL ASSEMBLIES January 2018 Water vapor is the invisible source of many problems found in buildings today.

More information

ENERGY SAVINGS FOR LIFE

ENERGY SAVINGS FOR LIFE Design Characteristics of Spray Polyurethane Foam Insulation ENERGY SAVINGS FOR LIFE Spray Polyurethane Foam Insulation FEATURES Spray Applied Excellent Adhesion Lightweight Safe High Insulation Value

More information

Distinguish your homes with spray foam insulation from a name you can trust.

Distinguish your homes with spray foam insulation from a name you can trust. CertainTeed Open Cell Spray Foam Insulation Distinguish your homes with spray foam insulation from a name you can trust. CertaSpray Open Cell Foam Insulation insulates and seals in one step. THERE ARE

More information

Delivering. 3M Window Films. on Your Bottom Line. 3M Renewable Energy Division

Delivering. 3M Window Films. on Your Bottom Line. 3M Renewable Energy Division 3M Renewable Energy Division Delivering 3M Window Films on Your Bottom Line Creating a more efficient building envelope is an essential step in optimizing your building for energy efficiency and helping

More information

Inside Why Spray polyurethane Foam insulation? All About Spray polyurethane Foam Book 1

Inside Why Spray polyurethane Foam insulation? All About Spray polyurethane Foam Book 1 Foam Book Inside Why Spray polyurethane Foam insulation? All About Spray polyurethane Foam Book 1 SUSTAIN THROUGH KNOWLEDGE Book 1: Why Spray Polyurethane Foam Insulation Book 2: SPF & Thermal Barrier

More information

Knauf Data Sheet BI-DS Thermal/Acoustical Insulation

Knauf Data Sheet BI-DS Thermal/Acoustical Insulation Knauf Data Sheet BI-DS-7 9-09 Thermal/Acoustical Insulation Knauf EcoBatt Think of it as green...only browner. Insulation with ECOSE Technology... All Knauf products are sustainable. EcoBatt Glasswool

More information

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016 CHEBOYGAN COUNTY DEPARTMENT OF BUILDING SAFETY 870 South Main Street P.O. Box 70 Cheboygan, Michigan 49721 Phone: (231) 627-8813 Fax: (231) 627-8454 www.cheboygancounty.net 2015 MICHIGAN UNIFORM ENERGY

More information

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process NC Energy Code Requirements ENERGY STAR and NC Energy Code in Alignment RESNET Standards HERS Index A scoring

More information

Open and Closed Cell Spray Foam Insulation

Open and Closed Cell Spray Foam Insulation Open and Closed Cell Spray Foam Insulation Complete Comfort CertaSpray has it covered Comfort starts with thermal performance, but it doesn t end there. Complete Comfort comes in an environment free from

More information

Analysis of Differences between 2018 IECC R406 Code Compliance and ANSI/RESNET/ICC Standard 301

Analysis of Differences between 2018 IECC R406 Code Compliance and ANSI/RESNET/ICC Standard 301 Analysis of Differences between 2018 IECC R406 Code Compliance and ANSI/RESNET/ICC Standard 301 FSEC-CR-2081-18 Final Report May 16, 2018 Submitted to Residential Energy Services Network, Inc. P.O. Box

More information

DOE Zero Energy Ready Home Technical Training

DOE Zero Energy Ready Home Technical Training Design Options for Locating Ducts within Conditioned Space DOE Zero Energy Ready Home Technical Training Jamie Lyons, P.E. DOE Zero Energy Ready Home 1 INNOVATION & INTEGRATION: Transforming the Energy

More information

HP+ Building Enclosure Systems. Affordable Solutions for Title 24 and Beyond

HP+ Building Enclosure Systems. Affordable Solutions for Title 24 and Beyond HP+ Building Enclosure Systems Affordable Solutions for Title 24 and Beyond BASF High Performance Envelope Solutions Reduce moisture risk Improve Title 24 compliance margin Save materials and labor on

More information

Thermal/Acoustical Insulation. Knauf Data Sheet BI-BT-DS 08-13

Thermal/Acoustical Insulation. Knauf Data Sheet BI-BT-DS 08-13 Thermal/Acoustical Insulation Knauf Data Sheet BI-BT-DS 08-13 Think of it as green...only browner. Knauf EcoBatt Insulation with ECOSE Technology All Knauf products are sustainable. EcoBatt Glasswool Insulation

More information

Building Envelopes 101

Building Envelopes 101 Session: Foundation Building Block 1 Building Envelopes 101 Diana Hun, PhD Oak Ridge National Laboratory August 9, 2016 Rhode Island Convention Center Providence, Rhode Island US Primary Energy Consumption

More information

Daran Wastchak. D.R. Wastchak, L.L.C.

Daran Wastchak. D.R. Wastchak, L.L.C. The Principles of Applied Building Science Building The High Performance Home Presented By Daran Wastchak D.R. Wastchak, L.L.C. All rights reserved. Reproduction and/or use of this document and its contents

More information

National Institute of Building Sciences. Paul Totten, PE, LEED AP Vice President, National Practice Leader, Building Enclosures

National Institute of Building Sciences. Paul Totten, PE, LEED AP Vice President, National Practice Leader, Building Enclosures National Institute of Building Sciences Provider Number: G168 Design Considerations for Climate Change Session TU1A Paul Totten, PE, LEED AP Vice President, National Practice Leader, Building Enclosures

More information

Save up to 40% on utility bills with Nu-Wool Premium Cellulose Insulation

Save up to 40% on utility bills with Nu-Wool Premium Cellulose Insulation * Save up to 40% on utility bills with Nu-Wool Premium Cellulose Insulation What is Nu-Wool Insulation? What is Nu-Wool Premium Cellulose Insulation? Nu-Wool Premium Cellulose Insulation is an energy-saving

More information

Building with Ducts in Conditioned Spaces Conditioned Attics

Building with Ducts in Conditioned Spaces Conditioned Attics Building with Ducts in Conditioned Spaces Conditioned Attics Application: This approach is most useful in single-story homes, because it allows easy access to every room. It could also be used for the

More information

RESNET HERS Index and the 2015 IECC

RESNET HERS Index and the 2015 IECC RESNET HERS Index and the 2015 IECC RESNET Building Performance Conference February 16, 2015 Philip Fairey A Research Institute of the University of Central Florida Overview EnergyGauge USA v.2.8.05 analysis

More information

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012 THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012 Compliance with the code for new residential construction, additions, and substantial remodels will

More information

Comfort RX Case Studies

Comfort RX Case Studies For more information, please contact: Amber Davis OR Kristen Lewis AKHIA Comfort RX 330.463.5650 330-798-4600 amber.davis@akhia.com klewis@comfortrx.com Comfort RX Case Studies Uniontown, Ohio As people

More information

Insulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes

Insulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes Insulating Attics & Crawlspaces Roger Morrison, PE, RRC NCFI Polyurethanes Unvented vs. Vented Vented Space is vented to the outside Space is unconditioned Unvented Space does not communicate with outside

More information

2013 COMMERCIAL PRODUCTS

2013 COMMERCIAL PRODUCTS 2013 COMMERCIAL PRODUCTS EXPLORE GEOMETRY AND SPACE WITHOUT COMPROMISING BUILDING ENVELOPE PERFORMANCE Commercial design considerations come with very specific challenges that can t be addressed with just

More information

Lock In Energy Savings For Life

Lock In Energy Savings For Life Lock In Energy Savings For Life AN ENVIRONMENTALLY FRIENDLY HOME IS A GREAT BENEFIT FOR YOU, YOUR FAMILY AND THE ENVIRONMENT. TAKE AN ACTIVE ROLE IN HELPING REDUCE GREENHOUSE GASES, THUS SLOWING THE EFFECTS

More information

All of Alaska in Zone 7 except for the following Boroughs in Zone 8: Northwest Arctic. Yukon-Koyukuk. North Slope ADD INSULATION TO ATTIC

All of Alaska in Zone 7 except for the following Boroughs in Zone 8: Northwest Arctic. Yukon-Koyukuk. North Slope ADD INSULATION TO ATTIC DO-IT YOURSELF ATTIC INSTALLATION INSTRUCTIONS GREENFIBER CELLULOSE FIBER INSULATION HOW TO INSTALL 1 Calculate How Much GreenFiber Insulation You Need First, determine the R-value recommended for your

More information

Feature Zone IECC 2009 IECC

Feature Zone IECC 2009 IECC Feature Zone 3 2006 IECC 2009 IECC Window U factor 0.65 0.50 Skylight U factor 0.65 0.65 Window SHGC 0.40 0.30 Ceiling R value 30 30 Wood frame R value 13 13 Mass wall R value 1 5 5/8 Floor R value 19

More information

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation INTRODUCTION As the use of spray polyurethane foam (SPF) insulation is increasing in both

More information

Residential Energy Code Update

Residential Energy Code Update Residential Energy Code Update www.phrc.psu.edu August 28 th, 2018 Brian Wolfgang Provider # 60114115 PPP ID: 1562 Description On May 1, 2018, the PA Uniform Construction Code (PA UCC) Review and Advisory

More information

The Building Envelope Solution. Mike Lowery A&D Products, LLC

The Building Envelope Solution. Mike Lowery A&D Products, LLC The Building Envelope Solution Mike Lowery A&D Products, LLC Provider # K031 Course # CCM121 The industries ONLY single-source material performance and tie-in warranty for all 6 sides of your building!

More information

Air Sealing for 5 ACH 50

Air Sealing for 5 ACH 50 November 13th, 2018 Christopher Hine Air Sealing for 5 ACH 50 www.phrc.psu.edu Provider # 60114115 PPP ID: 1562 November 13th, 2018 Christopher Hine Air Sealing for 5 ACH 50 www.phrc.psu.edu Provider #

More information

Pennsylvanians Buying 2012 IECC Homes Will Save Thousands

Pennsylvanians Buying 2012 IECC Homes Will Save Thousands Pennsylvanians Buying 2012 IECC Homes Will Save Thousands An Analysis of Cumulative Homeowner Profit after Paying Incremental Construction Costs for New Single Family Homes Meeting Building Energy Code

More information

Utah Residents Buying 2012 IECC Homes Will Save Thousands

Utah Residents Buying 2012 IECC Homes Will Save Thousands HIGHLIGHTS Utah Residents Buying 2012 IECC Homes Will Save Thousands An Analysis of Homeowner Profit after Paying Incremental Construction Costs For New Single Family Homes Meeting the Building Energy

More information

Premium Loose Fill Fiber Glass Insulation

Premium Loose Fill Fiber Glass Insulation Premium Loose Fill Fiber Glass Insulation Locate a contractor near you, visit CertainTeed.com/findapro Insulation types Every material resists the flow of heat but some are more efficient insulators than

More information

2015 IECC Air Sealing Multifamily For Code Compliance Funding for Energy Code Training

2015 IECC Air Sealing Multifamily For Code Compliance Funding for Energy Code Training 2015 IECC Air Sealing Multifamily For Code Compliance 2 Funding for Energy Code Training 1 Sponsor Also Recognize Resources Provided by Department of Energy: DOE Building America Program https://www.energycodes.gov/

More information

currently referenced throughout the

currently referenced throughout the STANDARD WORK SPECIFICATIONS: HOME ENERGY UPGRADES FOR EXISTING MANUFACTURED HOMES Page 1 of 4 General Comments 1. The work specifications for manufactured housing should be the same as the specifications

More information

Energy Compliance Information

Energy Compliance Information Midway City Building Safety 435-654-7441 X 2 (Fax) 435-654-4120 Energy Compliance Information Meeting the energy code in today s structures requires the integration of all systems within the thermal envelope,

More information

Energy Compliance Information

Energy Compliance Information Midway City Building Safety 435-654-7441 X 2 (Fax) 435-654-4120 Energy Compliance Information Meeting the energy code in today s structures requires the integration of all systems within the thermal envelope,

More information

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation 07 21 19 Foamed-in-place insulation 07 21 29 Sprayed insulation Spray Foam Insulation for Residential Building Envelope Insulation PART 1 - GENERAL 1.1 SUMMARY This document discusses the application of

More information

ICC-ES Evaluation Report. ESR-3102 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

ICC-ES Evaluation Report. ESR-3102 Reissued July 1, 2013 This report is subject to renewal August 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3102 Reissued July 1, 2013 This report is subject to renewal August 1, 2015. A Subsidiary of the International Code Council DIVISION:

More information

An Introduction to Spray Foam Insulation

An Introduction to Spray Foam Insulation An Introduction to Spray Foam Insulation Program Registration BNP Media is a registered provider with The American Institute of Architects Continuing Education System. Credit(s) earned upon completion

More information

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Please add relevant logo here Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Presented by: Peter J. Arsenault, FAIA, NCARB, LEED-AP Disclaimer: This presentation was developed by

More information

THE PERFORMANCE INSULATION SYSTEM THAT DELIVERS CLIMATE ISOLATION CONTRACTORS

THE PERFORMANCE INSULATION SYSTEM THAT DELIVERS CLIMATE ISOLATION CONTRACTORS THE PERFORMANCE INSULATION SYSTEM THAT DELIVERS CLIMATE ISOLATION CONTRACTORS The ultimate spray foam insulation. JM Corbond III closed-cell spray polyurethane foam (SPF) is a premium insulation perfectly

More information

EXPLORE GEOMETRY AND SPACE

EXPLORE GEOMETRY AND SPACE COMMERCIAL PRODUCTS EXPLORE GEOMETRY AND SPACE WITHOUT COMPROMISING BUILDING ENVELOPE PERFORMANCE Commercial design considerations come with very specific challenges that can t be addressed with just any

More information

About Southface. Southface promotes sustainable homes, workplaces and communities through education, research, advocacy and technical assistance.

About Southface. Southface promotes sustainable homes, workplaces and communities through education, research, advocacy and technical assistance. About Southface Southface promotes sustainable homes, workplaces and communities through education, research, advocacy and technical assistance. 1 Photo: Jonathan Hillyer, 2009 2 Green Building Services

More information

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

Kansas City Residents Buying 2012 IECC Homes Will Save Thousands

Kansas City Residents Buying 2012 IECC Homes Will Save Thousands Kansas City Residents Buying 2012 IECC Homes Will Save Thousands An Analysis of Cumulative Homeowner Profit after Paying Incremental Construction Costs for New Single Family Homes Meeting Building Energy

More information

THE ILLIANA HOME INSULATION GUIDE

THE ILLIANA HOME INSULATION GUIDE THE ILLIANA HOME INSULATION GUIDE Retrofitting existing homes with foam insulation Your home is one of your biggest investments and where you spend a majority of your life. From the color of your walls

More information

Integrated Solutions for Every Insulation Need. Complete Comfort

Integrated Solutions for Every Insulation Need. Complete Comfort Integrated Solutions for Every Need Complete Comfort Create a More Comfortable Home Your insulation choice impacts thermal performance as well as moisture management, air tightness and acoustics. It s

More information

A home isn t complete until it s

A home isn t complete until it s A home isn t complete until it s ENERGYCOMPLETE Today s homebuyers are looking for comfort and energy efficiency. Give them both with EnergyComplete flexible air sealant. The complete story EnergyComplete

More information

Spray Foam and the Building Codes

Spray Foam and the Building Codes Designing For The Future Spray Foam and the Building Codes New England Building Officials October 7, 2015 www.icynene.com Randy Nicklas, Senior Engineer Presentation Objectives Why Spray Polyurethane Foam

More information

Healthy, Durable, Low Energy Buildings: Thermal: High R. Thermal bridges. Fundamentals, techniques, and pitfalls

Healthy, Durable, Low Energy Buildings: Thermal: High R. Thermal bridges. Fundamentals, techniques, and pitfalls Dr John Straube, P.Eng. Associate Professor, University of Waterloo Principal, Building Science Corporation Healthy, Durable, Low Energy Buildings: Fundamentals, techniques, and pitfalls Thermal: High

More information

The Lower The HERS Score The Better. Tight Building Envelope. Renewable Energy Sources. Materials & Waste Management. Energy Efficient Lighting

The Lower The HERS Score The Better. Tight Building Envelope. Renewable Energy Sources. Materials & Waste Management. Energy Efficient Lighting Green Guide 2018 Tight Building Envelope Controlling, thermal flow and moisture flow using advanced framing techniques, sophisticated insulation, air sealing tight ducts and air barriers to prevent air

More information

New Approaches to Energy Efficiency & Green Building. Who is Icynene Inc.? World-Wide Distribution. The Icynene Insulation System

New Approaches to Energy Efficiency & Green Building. Who is Icynene Inc.? World-Wide Distribution. The Icynene Insulation System The Icynene Insulation System New Approaches to Energy Efficiency & Green Building Control of Air Leakage and Moisture Vapour Transmission Who is Icynene Inc.? Founded in November, 1986 in Toronto Canada

More information

HOUSE DETAILS House Plan with dimensions (From House Website) First Floor Plan

HOUSE DETAILS House Plan with dimensions (From House Website) First Floor Plan Questionnaire for FBC, Field study of Sealed Attics for Florida Home Identity: House 2, Concrete tile roof with ocspf sealed attic Interviewers: Dr. William A. Miller, Oak Ridge National Laboratory, Mitali

More information

Premium Blown-in Insulation System

Premium Blown-in Insulation System Premium Blown-in Insulation System Premium Blown-in Insulation System Everything you re looking for in your insulation and more. Specially designed for closed cavity applications Outstanding thermal and

More information

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017 Truss Heel Heights and Energy Code Requirements Overview Revised 2/17/2017 SBCA has been the voice of the structural building components industry since 1983, providing educational programs and technical

More information

Cellulose Insulation Products. Date: Submitted to: Submitted by: Job Reference: Job Name

Cellulose Insulation Products. Date: Submitted to: Submitted by: Job Reference: Job Name Submittal Form Cellulose Insulation Products Date: Submitted to: Submitted by: Job Reference: Job Name This submittal form is provided to assist you in specifying and selecting the proper GREENSHIELD Cellulose

More information

This page has been left blank intentionally.

This page has been left blank intentionally. This page has been left blank intentionally. 2012 IECC Savings Analysis - IDAHO 2 Summary Idaho residents buying new single family homes meeting the 2012 International Energy Conservation Code (IECC) will

More information

Air Infiltration & Insulation

Air Infiltration & Insulation Control of Air Flow as Part of Thermal Insulation Manufacturer s Instructions to Achieve Energy Efficiency of Any Building Address the role of insulation in a home Today s Presentation Review common types

More information

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition Spray Polyurethane Foam Design Guidance Insulation and Air Barrier Requirements of the 2012 I-Codes Spray Foam Coalition about the collaboration the center for the polyurathanes industry (CPI) of the

More information

STRUCTURAL INSULATED PANEL ASSOCIATION (SIPA) Title 24 And High Performance Structural Insulated Panel Systems (SIPS)

STRUCTURAL INSULATED PANEL ASSOCIATION (SIPA) Title 24 And High Performance Structural Insulated Panel Systems (SIPS) STRUCTURAL INSULATED PANEL ASSOCIATION (SIPA) Title 24 And High Performance Structural Insulated Panel Systems (SIPS) What are SIPS? Structural Insulated Panels OSB skins laminated with a structural adhesive

More information

Energy-Efficient Facilities: Building Envelope Design. Wall Systems. Copyright Materials. Course Description

Energy-Efficient Facilities: Building Envelope Design. Wall Systems. Copyright Materials. Course Description Energy-Efficient Facilities: Building Envelope Design Steve Easley steve@steveeasley.com Wall Systems www.steveeasley.com Copyright Materials This presentation is protected by US and International Copyright

More information

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 11-15

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 11-15 Thermal/Acoustical Insulation Data Sheet BI-BT-DS 11-15 Think of it as green...only browner. Knauf Insulation EcoBatt Insulation with ECOSE Technology All Knauf Insulation products are sustainable. EcoBatt

More information

Opportunities for BaySystems Spray Foam & Specialty Coatings to Contribute to USGBC s LEED Performance

Opportunities for BaySystems Spray Foam & Specialty Coatings to Contribute to USGBC s LEED Performance Opportunities for BaySystems Spray Foam & Specialty Coatings to Contribute to USGBC s LEED Performance LEED OPPORTUNITIES BaySystems products offer numerous opportunities to contribute to the performance

More information

This article will address the test methods used to determine R-values and their relative degree of accuracy.

This article will address the test methods used to determine R-values and their relative degree of accuracy. Insulation R-value, What does it really mean? Every designer knows that the R-value of a material is important in specifying insulation products. Regulations abound that require minimum R-values for wall,

More information

ENERTITE. More Than Just Insulation Low Density Insulation. Raising Performance To New Heights

ENERTITE. More Than Just Insulation Low Density Insulation. Raising Performance To New Heights ENERTITE More Than Just Insulation Low Density Insulation Raising Performance To New Heights Over 9,000 people dedicated to raising performance Innovative products are at the source of BASF s success.

More information

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and PREP + INSULATION HOME ENERGY UPGRADES What every contractor needs to know. Copyright 2012 Advanced Energy. All Rights Reserved 103 HOME ENERGY UPGRADES Prep + Insulation Contents Air sealing is a challenging

More information

Rebates for Improvements Home Efficiency Program Fort Collins Utilities

Rebates for Improvements Home Efficiency Program Fort Collins Utilities Rebates for Improvements Home Efficiency Program Fort Collins Utilities Revised 03/04/2013 This matrix summarizes information regarding Home Efficiency Program rebates for improving homes in Fort Collins.

More information

Working Smart with Low Pressure Spray Polyurethane Foam. Leba Lualdi, Fomo Products, Inc BPI Certified Building Analyst

Working Smart with Low Pressure Spray Polyurethane Foam. Leba Lualdi, Fomo Products, Inc BPI Certified Building Analyst Working Smart with Low Pressure Spray Polyurethane Foam Leba Lualdi, Fomo Products, Inc BPI Certified Building Analyst Fomo Products, Inc. Manufacturer of low pressure polyurethane foam since 1975 Located

More information

Product Specification

Product Specification Product Specification 1. PRODUCT NAME NU-WOOL Premium Cellulose Insulation and WALLSEAL are registered trademarks for NU- WOOL Co., Inc. 2. MANUFACTURER NU-WOOL Premium Cellulose is made from recycled

More information

SIP Homes: Built for a Lifetime of Comfort and Value

SIP Homes: Built for a Lifetime of Comfort and Value Innovative Steel Structures (949) 607-9729 leosmarthomes@gmail.com SIP Homes: Built for a Lifetime of Comfort and Value In also offer high-performance, sustainable homes made with Structural Insulated

More information

6747 Campobello Road Mississauga, Ontario, Canada

6747 Campobello Road Mississauga, Ontario, Canada 6747 Campobello Road Mississauga, Ontario, Canada 800.758.7325 info@icynene.com This specification utilizes the Construction Specifications Institute s (CSI) 3-Part formatting. The specification is a manufacturer-specific

More information

Homes Across Nebraska Are Being Built to the Latest National Energy Standards Is Yours?

Homes Across Nebraska Are Being Built to the Latest National Energy Standards Is Yours? Homes Across Nebraska Are Being Built to the Latest National Energy Standards Is Yours? A home buyer s guide to the energy efficiency requirements of the 2012 International Energy Conservation Code Nebraska

More information

PICK YOUR POISON AND HOW TO GET THERE. Presented By Robby Schwarz

PICK YOUR POISON AND HOW TO GET THERE. Presented By Robby Schwarz PICK YOUR POISON AND HOW TO GET THERE Presented By Robby Schwarz Code Adoption Cycle 2012 International Energy Conservation code The code that got peoples attention Adoption and development are out of

More information

Table Air Barrier and Insulation Inspection Component Criteria

Table Air Barrier and Insulation Inspection Component Criteria Table 40.4. Air Barrier and Insulation Inspection Component Criteria NUMBER COMPONENT CRITERIA Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial

More information

Charter Township of Washington

Charter Township of Washington Charter Township of Washington Building Department 57900 V an Dyke Washington, MI. 48094 Phone:(586) 786-0010 Ext. 211 Fax: 586-752-6463 2015 Michigan Residential Code Energy Worksheet for New Single-family

More information

Why Control Heat flow? How to Control Heat Flow? Thermal Performance. Modes of heat transfer: Thermal Control: Insulation & Thermal Bridges

Why Control Heat flow? How to Control Heat Flow? Thermal Performance. Modes of heat transfer: Thermal Control: Insulation & Thermal Bridges Fundamentals Insulation and Thermal Bridges June 13-14, 2012 Why Control Heat flow? Joseph Lstiburek, Ph.D., P.Eng John Straube, Ph.D., P.Eng 2012 Thermal Control: Insulation & Thermal Bridges 1. Occupant

More information

Welcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series.

Welcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series. Welcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series. 1 3 6 7 8 The primary reasons to build airtight buildings are to avoid drafts

More information

California Building Envelope Solutions

California Building Envelope Solutions California Building Envelope Solutions Attics & Walls October 2017 What s New in 2016 Title 24 Attics High Performance Attic New prescriptive requirements Roof deck insulation in many CZs Walls High Performance

More information

Equipment Sizing: Manuals J & S

Equipment Sizing: Manuals J & S Equipment Sizing: Manuals J & S Massachusetts Energy Code Technical Support Program 1 Who Is Mass Save? Mass Save is an initiative sponsored by Massachusetts gas and electric utilities and energy efficiency

More information

Residential Construction

Residential Construction Structural Insulated Panels (SIPs) are modern engineered building components that combine great structural strength with outstanding energy performance. ERECTING A STRUCTURALLY SOUND THERMALLY EFFICIENT

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

2015 IECC Whole Building Air Leakage Compliance

2015 IECC Whole Building Air Leakage Compliance 2015 IECC Whole Building Air Leakage Compliance Presented by: Jeffrey Crowe, PE Project Manager www.becx.com www.pieglobal.com September 2012 Learning Objectives Understand 2015 International Energy Code

More information

Building Science Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, Straube buildingscience.com 1 of 24

Building Science Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, Straube buildingscience.com 1 of 24 Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Straube buildingscience.com 1 of 24 Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Straube buildingscience.com

More information

U.S. Environmental Protection Agency. Seal and Insulate with ENERGY STAR

U.S. Environmental Protection Agency. Seal and Insulate with ENERGY STAR U.S. Environmental Protection Agency Seal and Insulate with ENERGY STAR EPA 430F-09-052 March 2009 WHY SEAL AND INSULATE? Sealing and insulating the "envelope" or "shell" of your home its outer walls,

More information

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection Slab on Grade & Basements: A capillary break is installed on top of all footings Slab / Pre-Drywall / Thermal Inspection A minimum of 4" of clean or washed gravel (0.5" diameter or greater) is placed over

More information

CertaSpray Foam Insulation. Your dream. Your insulation.

CertaSpray Foam Insulation. Your dream. Your insulation. CertaSpray Foam Insulation Your dream. Your insulation. Enjoy comfort and peace of mind. CertaSpray foam insulation is your best choice for assuring the comfort and energyefficiency of your home. No more

More information

2006 Building Science Press All rights of reproduction in any form reserved.

2006 Building Science Press All rights of reproduction in any form reserved. building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 102 Understanding Attic Ventilation 2006-10-26 by Joseph Lstiburek Abstract: Attics

More information

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building 2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building Building Department 52700 Van Dyke, Shelby Township, MI 48316 Phone (586) 731-5969 Fax (586) 803-2099 building@shelbytwp.org

More information

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building 2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building Building Department 52700 Van Dyke, Shelby Township, MI 48316 Phone (586) 731-5969 Fax (586) 803-2099 building@shelbytwp.org

More information

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0 Qualifying Homes The following homes are eligible to earn the ENERGY STAR: Single-family homes; Units in multi-family buildings that are three stories or less; Units in multi-family buildings that are

More information

2012 CLEAResult All rights reserved. Residential Energy Efficiency

2012 CLEAResult All rights reserved. Residential Energy Efficiency Residential Energy Efficiency Presenter Bio Jaymar Davis, PE, CEM, CLEP, CMVP, CEA Sr. Field Engineering Manager 10 Years experience in energy efficiency Johnson Controls, Kohler Co. Certifications: Licensed

More information

The EnergyComplete System Enhances Building Energy Efficiency

The EnergyComplete System Enhances Building Energy Efficiency The EnergyComplete System Enhances Building Energy Efficiency Introduction A properly insulated building uses less energy for heating and cooling than the same building without insulation. The higher the

More information

Our sophisticated knowledge base and innovative product line promote quality green building methods, energy efficiency, comfort and health.

Our sophisticated knowledge base and innovative product line promote quality green building methods, energy efficiency, comfort and health. We provide specialized building supplies, expert guidance, and advanced education to architects, contractors, building owners, and construction industry professionals. Our sophisticated knowledge base

More information

Spray Polyurethane Foam in Unvented Cathedral Ceilings and Cathedralized Attics

Spray Polyurethane Foam in Unvented Cathedral Ceilings and Cathedralized Attics Spray Polyurethane Foam in Unvented Cathedral Ceilings and Cathedralized Attics RECOMMENDED DESIGN CONSIDERATIONS Spray Polyurethane Foam Alliance Copyright 2003 Re-Issued December 2008 To order copies

More information

INDEPENDENT REVIEWS DISCREDIT COLORADO STUDY

INDEPENDENT REVIEWS DISCREDIT COLORADO STUDY INDEPENDENT REVIEWS DISCREDIT COLORADO STUDY INTRODUCTION A 1990 study conducted at the University of Colorado at Denver ( Colorado Study ) is frequently cited to argue that cellulose insulation outperforms

More information

Energy Efficiency. Understanding R-value, Mass Walls, Continuous Insulation and Air Tightness By Bautex Systems, LLC

Energy Efficiency. Understanding R-value, Mass Walls, Continuous Insulation and Air Tightness By Bautex Systems, LLC Energy Efficiency Understanding R-value, Mass Walls, Continuous Insulation and Air Tightness By Bautex Systems, LLC R-Value isn t the only variable that affects a building s Energy Efficiency. How to talk

More information