Water Storage Tanks Catalog Revised

Size: px
Start display at page:

Download "Water Storage Tanks Catalog Revised"

Transcription

1 SCAFCO Water Storage Tanks Catalog Revised ENGLISH VERSION Water Storage Tanks, Inc. P.O. Box Austin, TX U.S.A.

2 Contents Warranty... 3 Standard Water Tank Models... 5 Specifications... 6 Water Tanks... 6 Bottomless Livestock Watering Tanks... 6 Water Tank Scope and Specifications... 6 Safety Information... 8 Water Tank Sheet Penetrations... 8 Ladder Packages and Components... 9 Exterior Ladder Packages - Ladder is Full Sidewall Height... 9 Ladder Security Cover Packages... 9 Exterior Ladder Components Safety Cage for Fall Prevention for Exterior Ladders Interior Ladder Mounting Components Safety Rest Platform Top Cap Hand Rail Packages Roof Accessories Roof Safety Ring Roof Safety Ring In Lieu of Safety Steps (When ordered with a Tank) Roof Support Ring Roof Reinforcing Ribs Tank Eave Seal Single Wind Ring Packages Corrugated Galvanized Foundation Rings Replacement Parts Roof Clips Bolts Miscellaneous Roof Cap Weatherskirts Segment Rings Roof Hatches (For Field Installation) Roof Panels Tank Wall Sheets Tank Bottom Wall Sheets Roof Assemblies and Components Complete 30 Roof Assembly Heavy Duty Roof Cap in Lieu of Standard Roof Starter Ring Packages Tank Venting Low-Profile Roof Vent Gooseneck Roof Vent Pipe Flashing and Penetration Flanges Pipe Flashing Penetration Flange Sets Penetration Boots Replacement Tank Liners Mil White PVC with Patch Kit Membrane Clamp Kits With Hardware Bottomless Livestock Watering Tanks X 2 0 (0.6 M) High with Plain Top Edge Bottomless Livestock Watering Tanks X 2 0 (0.6 M) High with Rolled Top Lip Bottomless Livestock Watering Tanks X 6 6 (1.98 M) High Page 2 Price and specifications subject to change without notice. April 1, 2009

3 Warranty The manufacturer warrants each new SCAFCO CORGAL water tank manufactured by it to be free from defects in material or workmanship FOR FIVE YEARS from the date of initial installation by the original purchaser. If such a defect is found by the manufacturer to exist within the five year period, the manufacturer will, at its option, (a) repair or replace such product free of charge, F.O.B. the factory of manufacture, or (b) refund to the original purchaser the original purchase price, in lieu of such repair or replacement. This Warranty includes CORGAL manufactured equipment only and does not extend to other suppliers' equipment. Water Storage Tanks, Inc. warrants to the original purchaser that if a SCAFCO CORGAL tank liner fails due to defective workmanship in fabrication of the liner within ten (10) years from date of original purchase, and the warranty form has been completed, signed, and returned to Water Storage Tanks, Inc. within thirty (30) days of purchase, Water Storage Tanks, Inc. will repair, or, at its option, replace the liner F.O.B. Austin, Texas on the following basis: Determination of repair or replacement shall be solely at the discretion of Water Storage Tanks, Inc. During the first year after date of original purchase, there shall be no charge to the original purchaser for repair or replacement. After the first year, a charge will be made. This charge will be a percentage of the retail price in effect at the time of replacement or repair. Percentages are based on the length of time from date of original purchase. The following schedule sets forth the percentage rate: After 1 year 25% After 4 years 55% After 7 years 85% After 2 years 35% After 5 years 65% After 8 years 90% After 3 years 45% After 6 years 75% After 9 years 95% After 10 years 100% This warranty is subject to the following terms and conditions: Water Storage Tanks, Inc. shall not be responsible for the cost of removal or replacement of any defective liner, nor for any other expenses or for damages which might be incurred in such removal or replacement. This warranty relates only to manufacturing defects and does not include damage or failure resulting from other causes, including, but not limited to, acts of God, misuse or abuse, accident or negligence, fire, improper installation, or ice damage. Fading, microbiological staining of the liner, or any damage induced by the improper use of chemicals is not covered by this warranty. If a liner should fail during the warranty period as a result of a manufacturing problem covered by this warranty, the original purchaser will notify Water Storage Tanks, Inc. in writing by mail. This notice will contain the liner serial number, date of purchase, and a description of the defect. Water Storage Tanks, Inc. will determine if the liner is to be returned to the factory or will ask that the (1) defective area and (2) the part of the liner stamped with the serial number be cut from the liner and returned. Liner, or liner pieces, must be cleaned and returned freight prepaid to: Water Storage Tanks, Inc., Hwy 290 West, Austin, TX Replacement liner will be shipped freight collect. April 1, 2009 Price and specifications subject to change without notice. Page 3

4 Conditions and Limitations The product must be installed and operated in accordance with instructions published by the manufacturer or warranty will be void. Warranty is void if all structural components of the system are not original equipment supplied by the manufacturer. Water tanks are designed for storing potable or non-potable water and are not warranted for other substances. Other use will void warranty. This product must be purchased from and installed by an Authorized Dealer or Certified Representative thereof or the warranty will be void. Malfunctions, damage or failure resulting from misuse, abuse, negligence, alteration, accident, misapplication of specifications or lack of proper maintenance shall not be considered defects under this warranty. Standard water tank design is for seismic zone 2B conditions and 90 mph wind. Any other loading condition must be requested (at extra cost) prior to order. Roof Snow Loads are shown below for various roof materials. Diameter (ft) 24 Gauge (PSF) 22 Gauge (PSF) Roof Ribs (PSF) Roof Ring (PSF) N/A N/A N/A The manufacturer shall not be liable for any consequential or special damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. "Consequential" or "Special Damages" as used herein include but are not limited to lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor, and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES THE MANUFACTURER'S ENTIRE AND SOLE WARRANTY AND THE MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD, AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. Any exceptions to this warranty must be authorized in writing by an officer of the manufacturing company. The manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models. WARNING: Galvanized materials are subject to unsightly "white rust" if moisture is allowed to penetrate the wall sheet or roof bundle. To avoid this condition, separate the wall sheets and roof panels so that air can dry the wall sheets. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Page 4 Price and specifications subject to change without notice. April 1, 2009

5 Standard Water Tank Models April 1, 2009 Price and specifications subject to change without notice. Page 5

6 Specifications Water Tanks The basic water tank includes a SCAFCO CORGAL water tank complete with all required wall sheets, roof panels, one roof panel with inspection hatch (except 6, 8 & 9 [1.83 M, 2.44M & 2.74 M] diameter), standard peak cap, roof ladder angles (except 6 [1.83 M] diameter), and roof safety steps (except 6, 8 & 9 [1.83 M, 2.44M & 2.74 M] diameter), inch (25 mil) white FDA PVC liner with patch kit, geo-textile fabric for interior wall and floor lining, liner hanger clips, sidewall access panel (except on one (1) ring tanks), anchor clips and necessary hardware for tank assembly. Bottomless Livestock Watering Tanks These tanks come complete with all required wall sheets, bolts, nuts and bead sealant. The final seal is at the jobsite with roof cement (by customer). Embed bottom of tank in concrete foundation. Water Tank Scope and Specifications 1) A SCAFCO CORGAL water storage tank is a storage system utilizing a corrugated, galvanized steel enclosure in conjunction with a liquid-tight PVC liner. The tank may be constructed with or without a conical galvanized steel roof. Tanks must be constructed on a concrete foundation. 2) Loads: The tank is designed to store potable or non-potable water with a density of 62.4 PCF. 3) Wall sheets are continuous 2-2/3" depth x 1/2" pitch (67.7 MM x 12.7 MM) corrugated galvanized steel with minimum yield strengths of 57,000 psi (3990 Kg/CM 2 ) (Tensile strength 65,000+ psi [4550 Kg/CM 2 +]). All zinc coating shall conform to G-115 (275 grams/square meter) specifications. Thicker zinc coatings are available by request. Wall sheets have a 42-2/3 (1,083.7 MM) nominal coverage. Bottom wall sheets have an inward return flange for additional bearing on foundation. Wall sheets have a coverage length of 9 4-1/2 (2,858 M) long, except for some 6 3 (1,905 MM) long sheets used adjacent to the access door. They are connected with high-strength bolts at the vertical and horizontal seams. a) Vertical seams are punched for single row or double row connections at 1-1/3 o.c (34 MM). Use of single row or double row of bolts at vertical seam is dependent upon diameter and depth of tank. b) Horizontal seams are a single lap connection, using a single row of high-strength bolts. Maximum bolt spacing shall be 9-3/8 (238 MM). 4) Tanks are supplied with a one-piece, 12 gauge (2.67 MM) galvanized steel die-formed anchor clip (minimum one provided per wall sheet). Anchor clip shall be bolted to the tank wall with four bolts. Anchor clip is designed to contact a concrete base. 5) Water tank roofs have a 30 slope, and use single-stage self-supporting roof sheets. Roof sheets are triangular sections of galvanized steel, with brake-formed raised ribs along each side, flat area between ribs (except 6, 8 & 9 [1.83 M, 2.44M & 2.74 M] diameter), and a 90 formed drip edge at the eave. Panels are manufactured from G-115 galvanized steel conforming to ASTM A 446, Grade C, or greater. Roofs of tanks 6 (1.83 M) diameter shall have 6 roof panels. Roofs of 8 (2.44 M) tanks shall have 8 roof panels. Roofs of 9 tanks (2.74 M) diameter tanks shall have 9 roof panels. Panels have a non-ribbed, flat design type, with crimped edge designed to seal over wall sheets. Roofs of tanks 12 & 15 (3.66 M & 4.57 M) have 23 panels (22 straight panels, and 1 double wide with roof hatch). Roofs of tanks 18 through 24 (3.66 M 7.32 M) diameter have 24 roof panels. Roofs of tanks 27 through 36 (8.23 M M) diameter have 36 roof panels. Panels shall have a formed box-type rib with a rib height of 3-1/4 inch (82 MM) rise above flat area. All roof panels (except 6, 8 & 9 [1.83 M, 2.44 M & 2.74 M]) shall be connected to the eave of the tank with Page 6 Price and specifications subject to change without notice. April 1, 2009

7 center clips and a varying number of rib clips depending on tank diameter. Holes in the top ring wall sheets are factory punched for clip installation. Roof ladder cleats extend from eave to center cap. Ladder cleats consist of galvanized steel cold-formed angles of varying lengths bolted to top of one roof panel. (Not supplied on 6 [1.83 M] diameter.) Center opening is 22 (560 MM) diameter for tanks 6 through 24 (1.83 M 7.32 M). Center opening is 36 (914 MM) diameter for tanks 27 through 36 (8.23 M M) diameter. Each roof 12 (3.66 M) diameter and larger shall have one panel equipped with a factory-installed hinged manhole door and latch. Roof manhole door is located at the eave next to the roof ladder. Manhole is trapezoidal shaped; dimensions are 24 x 16 x 19 (610 MM x 406 MM x 483 MM). Safety steps consisting of galvanized steel cold-formed angles shall be bolted to roof ribs around the perimeter of the center opening on tanks 12 (3.66 M) diameter and larger. Roof safety rings are available as an optional item. 6) Standard water tanks are designed for 90 MPH (144 KPH) wind speed, UBC Exposure C. 7) SCAFCO CORGAL tanks are designed for Seismic Zone 2B. The construction of many tanks will meet the Seismic Zone 3 or Seismic Zone 4 loading requirements. Check with the factory for applicability of particular tank sizes. 8) All bolts and nuts are electro-galvanized with JS-500 clear coat protective coating. Roof bolts have factoryinstalled steel-backed PVC washers. Wall sheet bolts have slotted button heads for insertion from inside toward outside. Special DT1500 coated bolts are available upon request. All bolts are heat treated and meet SAE Grade 8.2 or stronger specifications. Extruded bead sealant is supplied to seal the entire length of the vertical seam and approximately 12 of the horizontal seam at horizontal to vertical seam connections. Sealant between foundation and bottom wall sheet is not required unless concrete surface leaves a gap greater than 3/8. Standard erection and anchor bolt setting drawings and installation manuals are furnished with each tank. 9) Liner shall be fabricated from a flexible PVC material manufactured from FDA listed food grade materials capable of containing water. Minimum liner thickness shall be inches. Liners are usually white in color. All seams in tank liners are factory welded. Liner shall be suspended around the inside perimeter of the tank wall structure from liner hanger clips. Other liner materials are available by special quotation. Please consult Water Storage Tanks, Inc. Sales Department. 10) Optional Equipment a) Exterior Ladders: One-piece ladder sections 42-2/3 (1,084 MM) high with steps at 10-2/3 o.c. (271 MM), include ladder sections, ladder mounting brackets, hand-loops and attachment hardware. Entrance security covers are available as an option. b) Safety Equipment: Safety cage and safety rest platforms may be installed with vertical ladders where applicable. Roof stairway packages with handrail may be installed where required. c) Roof Vents: Low profile galvanized, steel roof vents may be installed as required to allow for filling and emptying tank without creating a pressurized condition inside the tank. April 1, 2009 Price and specifications subject to change without notice. Page 7

8 d) Interior Ladders: All aluminum interior ladders may be installed as required for entry and exit through the roof. Safety Information There are many safety issues to be addressed by the owner and builder of a new storage facility. The major safety items for a water tank are the wall ladders, access to roof openings, and safety inside a tank containing water. Ladders are designed in accordance with current Occupational Safety and Health Administration regulations and American National Standards Institute standards. Water Storage Tanks, Inc. policy is to provide only safe and usable products. However, as Water Storage Tanks, Inc. is rarely the designer, the decision regarding what ladder, cage or assembly to purchase is often left to the new owner, or the builder. Water Storage Tanks, Inc. can only provide the products purchased by its customers and therefore cannot be held responsible for omissions of necessary safety equipment. Warning labels are affixed to the roof hatch warning prospective entrants of the hazards of suffocation in the water. Again, as Water Storage Tanks, Inc. is not in control of personnel entering the tank, the responsibility for safety in the tank is transferred to the owner and/or entrant. Water Tank Sheet Penetrations Penetrations through tank wall sheets for plumbing or other requirements should be reinforced. If the opening is less than 17" (430 MM) dia., use a corrugated sheet with the same gauge as the sheet for reinforcement. This reinforcing sheet shall be full height and bolt to the horizontal seams on the top and bottom of the adjacent sheet. The sheet may be cut short of the vertical seams. However, it must extend at least 18" (450 MM) beyond either side of the penetration. It must have holes field drilled so that it can be bolted to the wall sheet in a pattern to match the adjacent vertical seam. For penetrations greater than 17" (430 MM), fit a corrugated reinforcing sheet with the gauge shown in the chart below. The dimensions of the reinforcing sheet and the attachment of the reinforcing sheet to the wall sheet shall be as previously described. Wall Sheet Gauge Reinforcing Sheet Gauge 8 (3.80 MM) Contact WST 10 (3.30 MM) 1/4 (6.35 MM) 11 (3.00 MM) 1/4 (6.35 MM) 12 (2.60 MM) 1/4 (6.35 MM) 13 (2.20 MM) 8 (3.80 MM) 14 (1.83 MM) 8 (3.80 MM) 15 (1.63 MM) 10 (3.30 MM) 17 (1.32 MM) 12 (2.60 MM) 18 (1.17 MM) 13 (2.20 MM) 20 (0.86 MM) 14 (1.83 MM) For openings greater than 28", or for openings through laminated wall sheets, contact Water Storage Tanks, Inc. Engineering Department. Page 8 Price and specifications subject to change without notice. April 1, 2009

9 Ladder Packages and Components Exterior Ladder Packages - Ladder is Full Sidewall Height PART NUMBER TANK HEIGHT FEET TANK HEIGHT METERS HAND LOOPS EST. POUNDS EST. KG LST 7' 3" LST 10' 9" LST 14' 4" LST LST LST Ladder Security Cover Packages Securit y Cover PART NUMBER DESCRIPTION Ladder Security Cover for 1 ladder section of coverage Ladder Security Cover for 2 ladder section of coverage Ladder as shown is not part of security cover package. POUNDS KG Ladder April 1, 2009 Price and specifications subject to change without notice. Page 9

10 PART NUMBER Exterior Ladder Components DESCRIPTION POUNDS KILOGRAMS /3" (1084 MM) Outside Ladder Section Angle Mount Bracket (Replaces ) Safety Cage Hoops Safety Cage Entrance Hoop Extension (2 Required) Safety Cage Bars (7 per section) Rest Platform Hand Loops (2 Required) Field Attach to Tank Roof " Inside Ladder Mount Brackets Ladder Rail Extension Safety Cage Stabilizer Bar Safety Cage for Fall Prevention for Exterior Ladders Safety Cage Hoop Safety Cage Bar Safety Cage Single Section Safety Cage on Ladder Page 10 Price and specifications subject to change without notice. April 1, 2009

11 Interior Ladder Mounting Components Part #ILMC-01 Component Package does not include the Actual Ladder Purchase Ladder Locally POUNDS KILOGRAMS Interior Ladder Components Kit Includes: 2 Ladder to tank wall aluminum mounting brackets /16 x ¾ bolts for ladder mounting angles Package 5/16 x 50 rope for ladder retraction Pulley for ladder retraction rope Eyebolt for pulley mounting /16 rod coupler nut PVC tube for mounting to bottom of ladder Rope cleat Inside Aluminum Ladder Interior Ladder Brackets Single Outside Ladder Section Hand Loop April 1, 2009 Price and specifications subject to change without notice. Page 11

12 Safety Rest Platform Comes complete with mounting brackets and hardware. Meets U.S. O.S.H.A. Safety Requirements. This may be used as an entrance platform for an access door. Handrails are 42" (1067 MM) in height; perforated platform is 29" x 36" (737 MM x 914 MM) with toe plates; and opening is 28" x 29" (711 MM x 737 MM). PART NUMBER POUNDS KG Top Cap Hand Rail Packages Round-shaped with one side open for entry. Fits all CORGAL tanks - 8' 4" (2.54 M) diameter. Includes galvanized steel hand rails and posts, 42" (1070 MM) high. Field assembly required. PART NUMBER POUNDS KG Page 12 Price and specifications subject to change without notice. April 1, 2009

13 Roof Accessories Roof Safety Ring Comes complete with mounting brackets and required hardware. PART NUMBER TANK DIAMETER FEET TANK DIAMETER METERS POUNDS KG Roof Safety Ring In Lieu of Safety Steps (When ordered with a Tank) Comes complete with mounting brackets and required hardware. PART NUMBER TANK DIAMETER FEET TANK DIAMETER METERS POUNDS KG R R Roof Support Ring Use in high wind areas. Comes complete with mounting brackets and required hardware. PART NUMBER TANK DIAMETER FEET TANK DIAMETER METERS POUNDS KG , 15, , 4.57, , 36, , 10.97, April 1, 2009 Price and specifications subject to change without notice. Page 13

14 For use in high wind or heavy snow conditions. Roof Reinforcing Ribs PART NUMBER TANK DIAMETER FEET TANK DIAMETER METERS POUNDS KG Tank Eave Seal Neoprene gasket sealer strip for use as tank eave seal or under roof cap, or under side roof access cover. PART NUMBER LB/KG Lb/ft Kg/ft. Page 14 Price and specifications subject to change without notice. April 1, 2009

15 Single Wind Ring Packages PART NUMBER BIN/SILO SIZE-FEET BIN/SILO SIZE-METERS (lb) (kg) , WIND RING SPLICE HALF, BOLT ON STYLE (2 REQD) 2 1 Wind Ring Package includes 2-3/8" (60 mm) O.D. tubing 21' (6400 mm) long, rolled to a specific bin/silo radius, attachment clips to vertical stiffeners, tubing splices and fasteners. The last piece of tubing requires a field cut. For Internal Wind Ring Packages, each splice is located on the attachment clip. WIND RING SPLICE CONNECTION DETAIL April 1, 2009 Price and specifications subject to change without notice. Page 15

16 For use as forms for concrete foundations. PART NO. ACTUAL RING DIA. (FT) Corrugated Galvanized Foundation Rings ACTUAL RING DIA. (M) 10 2/3 High x 14 Gauge WT. LB. WT. KG. PART NO. ACTUAL RING DIA. (FT) ACTUAL RING DIA. (M) WT. LB. WT. KG /3 Page 16 Price and specifications subject to change without notice. April 1, 2009

17 For use as forms for concrete foundations. PART NO. ACTUAL RING DIA. (FT) Corrugated Galvanized Foundation Rings ACTUAL RING DIA. (M) 24 High x 14 Gauge WT. LB. WT. KG. PART NO. ACTUAL RING DIA. (FT) ACTUAL RING DIA. (M) WT. LB WT. KG. 24 April 1, 2009 Price and specifications subject to change without notice. Page 17

18 Replacement Parts PART NUMBER DESCRIPTION Roof Clips POUNDS KILO- GRAMS ' To 36' (3.66 M To M) Center Clip (Each) ' To 36' (3.66 M To M) Rib Clip (Each) Bolts (Minimum Quantity Per Item is 100 Pieces) /16" (7.9 MM)-18 x 3/4" (19 MM) Bolt With Sealing Washer-Grade /C 1.5/C /16" (7.9 MM)-18 x 1¼" (32 MM) Bolt With Sealing Washer-Grade /C 1.86/C /16" (7.9 MM)-18 x 3/4" (19 MM) Truss Head Bolts With Sealing DT Washers-Grade /C 1.43/C 5/16 (7.9 MM)-18 x 3/4" (19 MM) Truss Head Bolts With Sealing Washers-Grade 8.2 with special DT coating 2.8/C 1.29/C /16" (7.9 MM) Sealing Washer (use for 1/4" only) 0.6/C.24/C /16" (7.9 MM) - 18 Hex Nut 1.2/C 0.54/C DT 5/16" (7.9 MM) - 18 Hex Nut with special DT coating 1.2/C 0.54/C /16 (7.9 MM) Plated Washers 1.3/C 0.59/C /8" (9.5 MM) Hex Nut 1.7/C 0.77/C /8" x 1" (9.5 MM x 25 MM) Button Head Bolts Grade /C 1.62/C /8" (9.5 MM) Plated Washers 1.58/C 0.72/C /8" (9.5 MM) Sealing Washers (use for 5/16" only) 0.42/C 0.19/C /16" (11 MM) Sealing Washers (use for 3/8" only) 0.55/C 0.25/C /8" x 12" (16 MM x 300 MM) Plated Anchor Bolt With Nut & Washer /4" x 12" (19 MM x 300 MM) Plated Anchor Bolt With Nut & Washer Miscellaneous Anchor Clip Anchor Clip Back-Up Plate /16" x 25' Long (4.8 MM x 7.62 M) Bead Sealant (48 rolls per case) Seismic Anchor Liner Patch Kit (4 oz can of adhesive & 3 Square feet of Mil Material) Neoprene Strips for Horizontal Seams 25' x 1 1/2" (76.2 m x mm) Neoprene Strips for Vertical Seams 25' x 3" (76.2 m x 76.2 mm) Access Panel Replacement Kit (not available for 1 ring tanks) Page 18 Price and specifications subject to change without notice. April 1, 2009

19 PART NUMBER DESCRIPTION LBS KG Roof Cap Roof Cap Assembly (6 9 [1.83 M 2.74 M]) Roof Cap Assembly (12' - 24' [3.66 M M]) Roof Cap Assembly (27' - 36' [8.23 M M]) Weatherskirts (3.66 M 4.57 M) High-Rib Weatherskirt - Box Rib Roof (One Piece) with Closeout Sheet ' - 24' (5.49 M M) High-Rib Weatherskirt - Box Rib Roof (One Piece) ' - 36' (8.23 M M) Weatherskirt Assembly (36 Pieces) Segment Rings (1.83 M 2.74 M) Roof Collar Ring ' - 24' (3.66 M M) High-Rib Segment Ring-Box Rib Roof ' - 36' (8.23 M M) Segment Ring Roof Hatches (For Field Installation) " X 16" X 19" Trapezoidal Inspection Hatch W/Hinged Cover Dia. Roof Inspection Hatch Assembly " Dia. Roof Inspection Hatch Assembly 20 9 Roof Panels PART NUMBER DESCRIPTION POUNDS KILOGRAMS (1.83 M) Roof Panel (EACH) Crimped Style (2.74 M) Roof Panel (EACH) Crimped Style ' (3.66 M) Roof Panel (EACH) ' (3.66 M) Roof Hatch Assembly (Double Wide Panel) ' (4.57 M) Roof Panel (EACH) ' (4.57 M) Roof Hatch Assembly (Double Wide Panel) ' (5.49 M) Roof Panel (EACH) ' (5.49 M) Roof Hatch Assembly ' (6.40 M) Roof Panel (EACH) ' (6.40 M) Roof Hatch Assembly ' (7.32 M) Roof Panel (EACH) ' (7.32 M) Roof Hatch Assembly ' (8.23 M) Roof Panel (EACH) ' (8.23 M) Roof Hatch Assembly ' (9.14 M) Roof Panel (EACH) ' (9.14 M) Roof Hatch Assembly ' (10.06 M) Roof Panel (EACH) ' (10.06 M) Roof Hatch Assembly ' (10.97 M) Roof Panel (EACH) ' (10.97 M) Roof Hatch Assembly April 1, 2009 Price and specifications subject to change without notice. Page 19

20 PART NUMBER Tank Wall Sheets DESCRIPTION COVER WIDTH/IN COVER WIDTH/MM LBS KG Gauge x 114.5" Top Wall Sheet (0.84 MM x 2910 MM) 42-2/3" Gauge x 114.5" Wall Sheet (0.84 MM x 2910 MM) 42-2/3" Gauge x 77" Wall Sheet (0.84 MM x 1956 MM) 42-2/3" Gauge x 114.5" Top Wall Sheet (1.14 MM x 2910 MM) 42-2/3" Gauge x 114.5" Wall Sheet (1.14 MM x 2910 MM) 42-2/3" Gauge x 77" Wall Sheet (1.14 MM x 1956 MM) 42-2/3" Gauge x 114.5" Wall Sheet (1.27 MM x 2910 MM) 42-2/3" Gauge x 77" Wall Sheet (1.27 MM x 1956 MM) 42-2/3" Gauge x 114.5" Wall Sheet (1.60 MM x 2910 MM) 42-2/3" Gauge x 77" Wall Sheet (1.60 MM x 1956 MM) 42-2/3" Gauge x 114.5" Wall Sheet (1.78 MM x 2910 MM) 42-2/3" Gauge x 77" Wall Sheet (1.78 MM x 1956 MM) 42-2/3" Gauge x 114.5" Wall Sheet (2.18 MM x 2910 MM) 42-2/3" Gauge x 77" Wall Sheet (2.18 MM x 1956 MM) 42-2/3" Gauge x 114.5" Wall Sheet (2.59 MM x 2910 MM) 42-2/3" Gauge x 77" Wall Sheet (2.59 MM x 1956 MM) 42-2/3" Gauge Header Sheet x 39½" (1.78 MM x 1003 MM) 13-1/ Gauge Header Sheet x 39½" (1.78 MM x 1003 MM) Gauge Header Sheet x 39½" (1.78 MM x 1003 MM) PART NUMBER DESCRIPTION Tank Bottom Wall Sheets COVER WIDTH/IN COVER WIDTH/MM LBS KG Gauge x 114.5" Top Sheet (0.84 MM x 2910 MM) 43-1/16" Gauge x 114.5" Sheet (0.84 MM x 2910 MM) 43-1/16" Gauge x 77" Sheet (0.84 MM x 1956 MM) 43-1/16" Gauge x 114.5" Top Sheet (1.14 MM x 2910 MM) 43-1/16" Gauge x 114.5" Sheet (1.14 MM x 2910 MM) 43-1/16" Gauge x 77" Sheet (1.27 MM x 1956 MM) 43-1/16" Gauge x 114.5" Sheet (1.27 MM x 2910 MM) 43-1/16" Gauge x 77" Sheet (1.27 MM x 1956 MM) 43-1/16" Gauge x 114.5" Sheet (1.60 MM x 2910 MM) 43-1/16" Gauge x 77" Sheet (1.60 MM x 1956 MM) 43-1/16" Gauge x 114.5" Sheet (1.78 MM x 2910 MM) 43-1/16" Gauge x 77" Sheet (1.78 MM x 1956 MM) 43-1/16" Gauge x 114.5" Sheet (2.18 MM x 2910 MM) 43-1/16" Gauge x 77" Sheet (2.18 MM x 1956 MM) 43-1/16" Gauge x 114.5" Sheet (2.59 MM x 2910 MM) 43-1/16" Gauge x 77" Sheet (2.59 MM x 1956 MM) 43-1/16" GA Sill Sheet x 39½" (1.78 MM x 1003 MM) 29-3/4" GA Sill Sheet x 39½" (1.78 MM x 1003 MM) 19-1/16" GA Sill Sheet x 39½" (1.78 MM x 1003 MM) 18-2/ GA Sill Sheet x 39½" (2.18 MM x 1003 MM) 29-1/ Page 20 Price and specifications subject to change without notice. April 1, 2009

21 Roof Assemblies and Components Complete 30 Roof Assembly PART NUMBER DIAMETER FEET DIAMETER METERS (lb) (kg) , , , , ,510 1,139 * ,545 1,608 * ,969 1, RAFTERLESS ,412 2,455 ** ,982 3,167 ** ,626 4,366 ** ,035 5,459 ** ,087 8,658 ** ,457 9,733 ** S ,080 10,015 ** ,462 12,003 ** ,198 15,512 ** ,139 24,557 Pre-punching of roof panels for gooseneck roof vents Consists of a complete set of roof panels, segment ring, weatherskirt, peak cap, inspection hatch (not included for 6 [1.83 m] and 9' [2.74 m] diameter roofs), necessary roof clips, center clips, and all installation bolts. * Includes roof support ring and reinforcing ribs standard. ** Includes rafters, purlins, clips Includes roof tension plates Consists of a complete set of single-span roof panels, segment rings, weatherskirt, 66 ¼ (1683 mm) peak cap, inspection hatch, roof support ring, reinforcing ribs, all necessary roof clips, center clips, and installation bolts. Note: Suffix "S" on the 75' roof assembly represents split rafters for export container loading. April 1, 2009 Price and specifications subject to change without notice. Page 21

22 Heavy Duty Roof Cap in Lieu of Standard PART NUMBER DIA. / FEET (lb) HDR 6' 24' Dia. (3.66 m 7.32 m) HDR 27' 42' Dia. (8.23 m 12.8 m) Please note: 48' 105' (14.63 m 32.0 m) Roof Assemblies include Heavy Duty Roof Cap (211375HD) as a Standard. FOR 60" ROOF CAP OPENING IN LIEU OF 36" ON 48' DIA. & LARGER ADD $ 2, PER ROOF ASSEMBLY. (kg) Roof Starter Ring Packages Roof starter rings are used to connect a high-rib roof structure to a non-matching tank structure. Starter rings are not available nor required for flat-seam roof structures. The starter ring package consists of rolled, corrugated galvanized steel sheets that are punched for assembly end-to-end and for assembly of the roof clips. Bolts and nuts are included for assembly of the ring and attachment of the roof clips. Tank eave seal is included for the top edge of the starter ring. PART NUMBER NOMINAL ROOF SIZE ACTUAL ROOF DIA. STARTER RING DIA. STARTER RING HT. RSR-06 6 HR RSR-08 8 HR RSR-09 9 HR RSR-06 6 SS RSR-08 8 SS RSR-09 9 SS RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR RSR HR (LBS) (KG) Page 22 Price and specifications subject to change without notice. April 1, 2009

23 Tank Venting Low-Profile Roof Vent Galvanized steel low profile roof vent. Free opening of 49 degrees. PART NUMBER POUNDS KILOGRAMS Inlet/Outlet Pipe Diameter Minimum Number of Vents Required 2 & & Gooseneck Roof Vent Complete galvanized roof vent with 1/2" (12.7 mm) mesh screen and galvanized steel angle base. Opening is at 90 degrees. PART NUMBER (lb) (kg) WD 18 8 *$25.00 Net packaging for LTL Shipments Includes Damper Assembly in Roof Vent April 1, 2009 Price and specifications subject to change without notice. Page 23

24 PART NUMBER SIZE BASE O.D. DIAMETER (INCHES) Pipe Flashing and Penetration Flanges Pipe Flashing Used to seal pipes entering tanks through the roof BASE O.D. (MM) PIPE O.D. DIAMETER PIPE O.D. MM LBS KG #1 4-3/ ¼ #2 6-1/ /4 3-1/ #3 7-3/ ¼ #4 9-1/ / #5 10-3/ /4 7-1/ #6 12-1/ #7 14-1/ #8 16-1/ Pipe Flashing Penetration Flange Penetration Flange Sets Used to connect piping to tank structures and liners. Set consists of tapped outer flange, gasket, inner flange, stainless sealing washers and bolts. PART NUMBER DIA. NOMINAL PIPE SIZE FLANGE OUTSIDE DIAMETER (LBS) (KG) PF-PVC-15 1 ½ 1 ½ PF-PVC PF-PVC PF-PVC PF-PVC PF-PVC PF-PVC PF-PVC PF-PVC PF-PVC PF-PVC PF-PVC Page 24 Price and specifications subject to change without notice. April 1, 2009

25 Penetration Boots Penetration boots are used to connect pipes that enter or exit a water storage tank to the flexible membrane liner. Penetration boot sets consist of a 25 mil., potable water rated, flexible liner boot, a stainless steel clamp used to clamp the nozzle of the boot to the pipe, a tube of Sikaflex 1A for sealing of the nozzle to the pipe and an 8 oz. can of PVC glue for bonding the liner flange to the main liner. April 1, 2009 Price and specifications subject to change without notice. Page 25

26 Replacement Tank Liners Mil White PVC with Patch Kit PART FOR TANK NUMBER MODEL NUMBER - LBS - KG WT WT PART NUMBER FOR TANK MODEL NUMBER -LBS -KG WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT WT 1, WT WT WT WT WT WT WT WT WT WT 1, WT WT 1, WT WT WT WT WT WT WT WT 1, WT WT 1, WT WT 1, Page 26 Price and specifications subject to change without notice. April 1, 2009

27 Membrane Clamp Kits With Hardware PART NUMBER TANK DIAMETER FEET TANK DIAMETER METERS LBS KG Individual Strip Any of Above Any of Above 11 5 Membrane Clamp St rip Tank wall MEMBRANE CLAMP STRIP DETAIL April 1, 2009 Price and specifications subject to change without notice. Page 27

28 MODEL NUMBER Bottomless Livestock Watering Tanks X 2 0 (0.6 M) High with Plain Top Edge CAPACITY GALLONS CAPACITY LITERS CAPACITY CUBIC FEET CAPACITY CUBIC METERS DIA. FEET DIA. METERS LBS KG 1224SRC 1,676 6, SRC 2,611 9, SRC 3,763 14, SRC 5,124 19, SRC 6,688 25, SRC 8,468 32,055 1, SRC 10,450 39,558 1, SRC 12,642 47,855 1, , SRC 15,050 56,970 2, , SRC 17,661 66,854 2, , MODEL NUMBER Bottomless Livestock Watering Tanks X 2 0 (0.6 M) High with Rolled Top Lip CAPACITY GALLONS CAPACITY LITERS CAPACITY CUBIC FEET CAPACITY CUBIC METERS DIA. FEET DIA. METERS LBS 1224RLSRC 1,676 6, RLSRC 2,611 9, RLSRC 3,763 14, RLSRC 5,124 19, RLSRC 6,688 25, RLSRC 8,468 32,055 1, RLSRC 10,450 39,558 1, RLSRC 12,642 47,855 1, , RLSRC 15,050 56,970 2, , RLSRC 17,661 66,854 2, , Above tanks include corrugated, galvanized steel sheets (12 gauge), bolts, nuts, and bead sealant. Embed bottom of tank in concrete foundation. KG Page 28 Price and specifications subject to change without notice. April 1, 2009

29 MODEL NUMBER Bottomless Livestock Watering Tanks X 6 6 (1.98 M) High CAPACITY GALLONS CAPACITY LITERS CAPACITY CUBIC FEET CAPACITY CUBIC METERS DIA. FEET DIA. METERS LBS KG 1278SRC 5,431 20, SRC 8,490 32,138 1, , SRC 12,231 46,299 1, , SRC 16,644 63,004 2, , SRC 21,738 82,287 2, , SRC 27, ,148 3, , SRC 33, ,556 4, , SRC 41, ,573 5, ,310 1, SRC 48, ,137 6, ,520 1, SRC 57, ,275 7, ,730 1,238 Above tanks include corrugated, galvanized steel sheets (top sheet 15 gauge, bottom sheet 14 gauge with bottom lip), double vertical and horizontal seal bolting, bolts, nuts and neoprene gaskets for vertical/horizontal seams. Embed bottom of tank in concrete foundation. April 1, 2009 Price and specifications subject to change without notice. Page 29

30

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans. INC. ENGINEERING/CONSTRUCTION/MANUFACTURING /WWW.CONTAINWATER.COM SPRINGS, TEXAS. 78620 MODEL SPECIFICATION FOR CONTAIN WATER INC. DOME ROOF CORRUGATED STEEL WATER STORAGE TANKS. Part 1 GENERAL 1.01 SECTION

More information

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans. INC. ENGINEERING/CONSTRUCTION/MANUFACTURING /WWW.CONTAINWATER.COM SPRINGS, TEXAS. 78620 MODEL SPECIFICATION FOR CONTAIN WATER INC. 30 DEGREE ROOF CORRUGATED STEEL WATER STORAGE Part 1 GENERAL 1.01 SECTION

More information

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders Welcome to the O Keeffe s Guide Specification System prepared as an aid to specify in preparing written construction documents. For specification assistance with specific product applications, please contact

More information

Water Storage Tank Assembly and Design Revised

Water Storage Tank Assembly and Design Revised Water Storage Tank Assembly and Design Revised 040109 ENGLISH VERSION Water Storage Tanks, Inc. P.O. Box 91493 Austin, TX 78709 U.S.A. e-mail: info@corgaltanks.com Contents Introduction... 3 Snow, Wind

More information

CHT06 COMMERCIAL HOPPER TANK 42 SHEET ERECTION MANUAL

CHT06 COMMERCIAL HOPPER TANK 42 SHEET ERECTION MANUAL CHT06 COMMERCIAL HOPPER TANK 42 SHEET ERECTION MANUAL 01-10-13 340675 - MANUAL CHIEF42 CHT06 Manual Revisions Date: Revision Made 01-06-09 Changed Roofs to 30 Degree 05-12-09 Changed temperature support

More information

SECTION 8130 XR-3-PW FABRIC BAFFLE WALL SPECIFICATION

SECTION 8130 XR-3-PW FABRIC BAFFLE WALL SPECIFICATION SECTION 8130 XR-3-PW FABRIC BAFFLE WALL SPECIFICATION PART 1 GENERAL 1.01 WORK INCLUDED 1.01.1 This specification covers the design, fabrication, and erection of tension-fabric baffle systems composed

More information

UNITED INDUSTRIES GROUP INC.

UNITED INDUSTRIES GROUP INC. SECTION 13205 AWWA D100-05 WELDED STEEL RESERVOIR SPECIFICATIONS REFERENCE SPECIFICATIONS, CODES AND STANDARDS. Commercial Standards: AWWA/ANSI D100-05 Welded Steel Tanks for Water Storage ASTM A36-01

More information

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL ALUMINUM RAILING SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Pipe Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in concrete.

More information

SECTION PRE-ENGINEERED METAL BUILDING

SECTION PRE-ENGINEERED METAL BUILDING SECTION 13121 PRE-ENGINEERED METAL BUILDING PART 1 GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to design, fabricate, deliver to project site, and erect

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION ALTERNATING TREAD STEEL STAIRS SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this

More information

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American

More information

SECTION CHAIN LINK FENCES AND GATES (PARK)

SECTION CHAIN LINK FENCES AND GATES (PARK) SECTION 02821 CHAIN LINK FENCES AND GATES (PARK) PART I GENERAL 1.1 SECTION INCLUDES A. Installation of chain link fences, and gate units provided by single source including erection accessories, fittings,

More information

SECTION CHAIN LINK FENCING

SECTION CHAIN LINK FENCING SECTION 02835 - CHAIN LINK FENCING 1.0 GENERAL 1.1 Furnish and install chain link fencing complete in place with gates and accessories as specified herein and as shown on the Contract Drawings. 1.2 Reference

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

TYPICAL ROOF CONDITION LAYOUT

TYPICAL ROOF CONDITION LAYOUT FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/

More information

SECTION WELDED STEEL WATER STORAGE TANKS

SECTION WELDED STEEL WATER STORAGE TANKS SECTION 33 16 20 WELDED STEEL WATER STORAGE TANKS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Elevated tanks. 2. Appurtenances and accessories. B. Related Sections: 1. Section 03 31 20 - Concrete

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS [OR WOOD] PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication

More information

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope. SECTION 08 4519 - POLYCARBONATE WALL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior System: The design, manufacture and installation of an aluminum and polycarbonate insulating translucent system.

More information

Trex Commercial Products page Metal Railing

Trex Commercial Products page Metal Railing SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Post Rail (Glass). D. Tensiline Railings (Cable). E. Track Rail (Glass).

More information

CB34 GRAIN BIN ROOF 40PSF - 50,000LB 90MPH PEAK

CB34 GRAIN BIN ROOF 40PSF - 50,000LB 90MPH PEAK CB34 GRAIN BIN ROOF 40PSF - 50,000LB 90MPH - 144 PEAK INSTALLATION MANUAL P/N 388784 Trusted. Tested. True. Chief Industries, Inc. Agri/Industrial Division Table of Contents Manual Revisions... 3 STANDARD

More information

PRE-ENGINEERED METAL BUILDING SYSTEM

PRE-ENGINEERED METAL BUILDING SYSTEM PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,

More information

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Post

More information

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE SECTION 13 34 00 METAL SHADE STRUCTURE PART 1 - GENERAL 1.01 STRUCTURE TYPE A. Structure shall be free standing rigid frame and gable roof with slopes as indicated. Structure shall also include foundation,

More information

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL ALUMINUM RAILING SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Decorative Wire Rope Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in

More information

WEC Manufacturing Phone: (901) Website: Itswec.com

WEC Manufacturing Phone: (901) Website: Itswec.com All Welded Plus Series Part 1: General 1.1 Construction Requirements: All lockers shall be powder coated steel as design and manufactured by WEC, Memphis, Tennessee. WEC will furnish all labor and materials

More information

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1 16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

B. Polyethylene samples shall be submitted for Owner approval of color and quality. Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING

More information

PIP STF05521 Details for Angle Railings for Walking and Working Surfaces

PIP STF05521 Details for Angle Railings for Walking and Working Surfaces TECHNICAL CORRECTION January 2017 Structural PIP STF05521 Details for Angle Railings for Walking and Working Surfaces PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of

More information

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011. DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:

More information

SECTION FLAT WALK-ON TYPE ALGAE CONTROL/LAUNDER COVERS

SECTION FLAT WALK-ON TYPE ALGAE CONTROL/LAUNDER COVERS PART 1 GENERAL 1.01 THE REQUIREMENT SECTION 11301 FLAT WALK-ON TYPE ALGAE CONTROL/LAUNDER COVERS A. The contractor shall furnish and install complete Flat Walk-On Algae Control/Launder Covers as shown

More information

SECTION ALUMINUM GEODESIC DOME. This section includes materials, fabrication and erection of the aluminum geodesic dome.

SECTION ALUMINUM GEODESIC DOME. This section includes materials, fabrication and erection of the aluminum geodesic dome. SECTION 133310 ALUMINUM GEODESIC DOME PART 1 - GENERAL A. Description This section includes materials, fabrication and erection of the aluminum geodesic dome. B. Related Work Specified Elsewhere 1. General

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION ALTERNATING TREAD STEEL STAIRS SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and install carbon steel or stainless steel alternating tread stair assemblies in accordance with the requirements

More information

HATCHSAFE Installation Instructions/Operation and Maintenance Manual Models: All Models

HATCHSAFE Installation Instructions/Operation and Maintenance Manual Models: All Models HATCHSAFE Installation Instructions/Operation and Maintenance Manual Models: All Models Contact Information Table of Contents: Safety Precautions... 2 Product Information... 2 Installation Instructions...

More information

Grain Bin Specifications

Grain Bin Specifications Grain Bin Specifications 1. GENERAL DESIGN INFORMATION a) All Chief Industries grain bins are designed for storage and handling of 49.5 PCF (793 kg/m 3 ) free flowing grain (52.5 PCF (841 kg/m 3 ) compacted

More information

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section. SECTION - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

More information

3' COMMERCIAL RIB PREFORMED METAL SIDING

3' COMMERCIAL RIB PREFORMED METAL SIDING SECTION 07410 3' COMMERCIAL RIB PREFORMED METAL SIDING PART 1 GENERAL 1.01 DESCRIPTION A. Work in this section includes furnishing and installation, preformed steel ribbed siding on vertical portions of

More information

SECTION METAL STAIRS

SECTION METAL STAIRS SECTION 05 51 00 METAL STAIRS PART 1 GENERAL 1.1 SUMMARY A. Section includes steel stair frame of structural sections, with closed risers; pan to receive concrete fill stair treads and landings; integral

More information

The Racking System Designed By Installers for Installers

The Racking System Designed By Installers for Installers The Racking System Designed PV Racking Ground System Installation Instructions Key benefits: Easy installation. No clamps! No more straining to lean over and fasten bolts! Module installation time is far

More information

POST FRAME BUILDING STANDARDS

POST FRAME BUILDING STANDARDS CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 POST FRAME BUILDING STANDARDS 201.3

More information

SECTION GROUND WATER STORAGE TANKS

SECTION GROUND WATER STORAGE TANKS SECTION 33 16 13 GROUND WATER STORAGE TANKS PART 1: GENERAL 1.01 SCOPE A. Section includes requirements for designing, fabricating, and erecting a welded steel ground storage tank. 1.02 SYSTEM DESCRIPTION

More information

Manufacturer of Coolers, Freezers, Step-Ins, Refrigeration Trailers and Sliding Doors COOLER AND FREEZER INSTALLATION MANUAL

Manufacturer of Coolers, Freezers, Step-Ins, Refrigeration Trailers and Sliding Doors COOLER AND FREEZER INSTALLATION MANUAL Manufacturer of Coolers, Freezers, Step-Ins, Refrigeration Trailers and Sliding Doors COOLER AND FREEZER INSTALLATION MANUAL http://www.walkincoolersandfreezers.com 786-286-2926 1 BEFORE INSTALLATION Please

More information

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS I N SULROCK FIRE RATED METAL PANELS GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS 1. GENERAL 1.1. Summary Fire-rated panels as shown on the drawings shall be INSULROCK brand panels as supplied by Green

More information

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows

More information

Flotation Docking Systems, Inc.

Flotation Docking Systems, Inc. GENERAL SPECIFICATIONS The following data outlines the design calculations and specifications around which Flotation Docking Systems, Inc. products are constructed. The use of such information for contract

More information

7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change.

7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change. Division 05. Metals 05 50 00. Metal Fabrications 05 50 00. Roof - Fall Protection The contractor shall provide a horizontal cable lifeline system on steel posts complying with applicable regulatory requirements.

More information

COMMERCIAL GRAIN SYSTEMS

COMMERCIAL GRAIN SYSTEMS SIOUX STEEL COMPANY COMMERCIAL GRAIN SYSTEMS 10 YEAR WARRANTIES On Sioux Steel Commercial Bins www.siouxsteel.com info@siouxsteel.com 1-800-557-4689 COMMERCIAL GRAIN SYSTEMS SIOUX STEEL COMPANY Innovative

More information

CB18 GRAIN BIN ROOF 60PSF - 30,000LB 90MPH - 72 PEAK

CB18 GRAIN BIN ROOF 60PSF - 30,000LB 90MPH - 72 PEAK CB18 GRAIN BIN ROOF 60PSF - 30,000LB 90MPH - 72 PEAK INSTALLATION MANUAL P/N 887416 Trusted. Tested. True. Chief Industries, Inc. Agri/Industrial Division Table of Contents Manual Revisions... 3 STANDARD

More information

SECTION COMPOSITE METAL DECKING

SECTION COMPOSITE METAL DECKING PART 1 GENERAL 1.1 DESCRIPTION SECTION 05 36 00 1. Use this section only for NCA projects. 2. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

SECTION 1043 FENCE MATERIAL

SECTION 1043 FENCE MATERIAL SECTION 1043 FENCE MATERIAL 1043.1 Scope. This specification covers the material required in the construction of chainlink fence and woven wire fence. 1043.2 Basis of Acceptance. The basis of acceptance

More information

13340 FIBERGLASS REINFORCED PLASTIC (FRP) ENCLOSURE

13340 FIBERGLASS REINFORCED PLASTIC (FRP) ENCLOSURE 13340 FIBERGLASS REINFORCED PLASTIC (FRP) ENCLOSURE PART1-GENERAL 1. SYSTEM DESCRIPTION a. Building Name: Pump Shelter 1. Size: Exterior Width: 6 ft Exterior Length: 6 ft Wall Height: 6 ft 2. Roof Slope:

More information

SAFE-TANK DOUBLE WALL TANKS HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61)

SAFE-TANK DOUBLE WALL TANKS HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61) SAFE-TANK DOUBLE WALL TANKS HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61) PART 1-GENERAL 1.01 Requirements 1. The CONTRACTOR shall provide SAFE-Tank

More information

SECTION DUALGARD SNOW GUARDS

SECTION DUALGARD SNOW GUARDS Copyright 2016 Metal Roof Innovations, Ltd. www.s-5.com SECTION 07 72 53 DUALGARD SNOW GUARDS This section has been prepared by Metal Roof Innovations, Ltd. for use in the preparation of a project specification.

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment

More information

ITEM 461 STRUCTURAL PLATE STRUCTURES. Galvanized steel plates shall conform to AASHTO M167 and aluminum plates shall conform to AASHTO M219.

ITEM 461 STRUCTURAL PLATE STRUCTURES. Galvanized steel plates shall conform to AASHTO M167 and aluminum plates shall conform to AASHTO M219. ITEM 461 STRUCTURAL PLATE STRUCTURES 461.1. Description. This Item shall govern for the furnishing and installing of structural plate pipes, pipe arches, arches, underpasses, box culverts and special shapes

More information

Diffused Aeration Piping Equipment

Diffused Aeration Piping Equipment 1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections

More information

B500-VRC / B600-VRC SERIES INSTRUCTIONS DETAILS RS-500-VRC INSTALLATION

B500-VRC / B600-VRC SERIES INSTRUCTIONS DETAILS RS-500-VRC INSTALLATION B500-VRC / B600-VRC SERIES INSTRUCTIONS DETAILS RS-500-VRC INSTALLATION SINGLE WALL VAPOR VENT / TRANSITION SUMPS This document contains specialized instructions for installing the RS-500-VRC Structural

More information

Sheet Metal Flashing and Trim

Sheet Metal Flashing and Trim University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 076200 - Sheet

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS. For best results, display hidden notes to specifier.

SECTION NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS. For best results, display hidden notes to specifier. SECTION 15062 NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS PART 1 GENERAL 1.1 SECTION INCLUDES For best results, display hidden notes to specifier. A. Portable, non-penetrating, rooftop support

More information

Fall Protection Catalogue CANADIAN

Fall Protection Catalogue CANADIAN Fall Protection Catalogue CANADIAN 2017 ALL PRICES IN CANADIAN DOLLARS Volume 4 / Issue 1 Visit www.trylon.com to view all the most recent catalogs. Table of Contents Safety Climb & Fall Protection Cougar

More information

Item 442 Metal for Structures

Item 442 Metal for Structures Item 442 Metal for Structures 1. DESCRIPTION 2. MATERIALS Provide structural steel, high-strength bolts, forgings, steel castings, iron castings, wrought iron, steel pipe and tubing, aluminum castings

More information

Top Dry Ladders, Safety Cage, and Platforms

Top Dry Ladders, Safety Cage, and Platforms Top Dry Ladders, Safety Cage, and Platforms Assembly Manual PNEG-1877 Date: 04-04-12 PNEG-1877 All information, illustrations, photos, and specifications in this manual are based on the latest information

More information

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS DIVISION 10 SPECIALTIES SECTION 10 51 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A. Division 01: Administrative, procedural, and temporary work requirements apply to this section.

A. Division 01: Administrative, procedural, and temporary work requirements apply to this section. Copyright 2016 Metal Roof Innovations, Ltd. www.s-5.com SECTION 26 31 00.01 PHOTOVOLTAIC COLLECTOR ATTACHMENT SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Photovoltaic Collector Attachment

More information

SECTION COLD-FORMED METAL TRUSSES

SECTION COLD-FORMED METAL TRUSSES SECTION 054400 COLD-FORMED METAL TRUSSES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

INSTALLATION MANUAL. Guardian Series. QSUS 18 x 40. Manual

INSTALLATION MANUAL. Guardian Series. QSUS 18 x 40. Manual Manual # Guardian Series INSTALLATION MANUAL QSUS 18 x 40 LE MANUEL D'INSTALLATION INSTALLATION HANDBUCH HANDBOEK VAN DE INSTALLATIE MANUAL DE LA INSTALACIÓN 03/07 Copyright 2005. All Rights Reserved.

More information

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL) ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL) 686.1. Description. This Item shall govern for designing, fabricating, furnishing and erecting steel traffic signal pole assemblies of the various types

More information

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF MODULAR PAN SYSTEM PART 1 GENERAL 1.1

More information

DL-200. Specifications

DL-200. Specifications DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01

More information

42'-135' X Series Ladder, Cage and Platform

42'-135' X Series Ladder, Cage and Platform 42'-135' X Series Ladder, Cage and Platform Assembly Instructions PNEG-1773 Version: 2.3 Date: 12-19-17 PNEG-1773 All information, illustrations, photos and specifications in this manual are based on the

More information

SECTION ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS

SECTION ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS PART 1: GENERAL 1.01 SUMMARY SECTION 04818 ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS A. Structural glass floor system, consisting of structural extruded aluminum System or Stainless Steel system and laminated

More information

SECTION METAL EQUIPMENT LOCKERS

SECTION METAL EQUIPMENT LOCKERS SECTION 10 51 13 - METAL EQUIPMENT LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified

More information

CHAIN LINK FENCES AND GATES

CHAIN LINK FENCES AND GATES SECTION 02831 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.01 SUMMARY A. Alternate Material for Fence Post and Framing Material: Where schedule 40 galvanized steel is specified, the following will be accepted:

More information

SECTION MISCELLANEOUS METALS

SECTION MISCELLANEOUS METALS PART 1 GENERAL 1.1 WORK OF THIS SECTION A. Contractor shall provide all labor, materials, equipment and incidentals as shown, specified and required to furnish and install all miscellaneous metal fabrications

More information

DRY BULK STORAGE TANK SPECIFICATION PREMIER POWDER COATED BOLTED STEEL TANK

DRY BULK STORAGE TANK SPECIFICATION PREMIER POWDER COATED BOLTED STEEL TANK DRY BULK STORAGE TANK SPECIFICATION PREMIER POWDER COATED BOLTED STEEL TANK 1. GENERAL 1.1 Scope of Work 1.1.1 Furnish and erect bolted RTP (rolled, tapered panel) steel tank for dry bulk storage. Scope

More information

INSTALLATION PROCEDURE

INSTALLATION PROCEDURE INSTALLATION PROCEDURE VOLU-probe/1, /3, /4 for Round Ducts INSPECTION & HANDLING. VOLU-probes should be carefully inspected for damage prior to installation. Report damage to your Freight Department,

More information

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM SECTION 13 34 21 - STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. The structural retrofit roof sub-framing system will provide support for a new metal roofing system constructed

More information

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,

More information

SECTION METAL FRAMED SKYLIGHTS

SECTION METAL FRAMED SKYLIGHTS SECTION 08630 - METAL FRAMED SKYLIGHTS PART 1: GENERAL 1.01 SUMMARY A. Section includes: Design, structural engineering, manufacture, fabrication, finishing of metal-framed skylights: 1. Glass and glazing

More information

Made in the US. 100% Recyclable

Made in the US. 100% Recyclable Made in the US 100% Recyclable ISE Advantage by Kloppenberg & Co Quality Stainless Steel Products Since 1941 Ice Storage Systems Uprights Shuttle Plus Storage Ice Fill Stations Ice Storage Dispensers Carts

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION HANGERS AND SUPPORTS FOR PLUMBING SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION GROUND STORAGE TANK

SECTION GROUND STORAGE TANK SECTION 13210 GROUND STORAGE TANK PART 1 GENERAL 1.01 Summary A. Section Includes: Provision for welded steel storage tank design, fabrication, construction and erection, including tank accessories. B.

More information

SECTION CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCES AND GATES SECTION 32 31 13 CHAIN LINK FENCES AND GATES SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Use this section in specifying permanent chain

More information

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Invisirail

More information

Model # PR /21/2018 Page 1 of 10

Model # PR /21/2018 Page 1 of 10 Model # PR-32 11/21/2018 Page 1 of 10 1/21/2018 Page 2 of 10 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

SECTION AWNINGS

SECTION AWNINGS SECTION 10 73 13 AWNINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Fixed metal awnings. 1.2 DEFINITIONS A. Awning: An architectural projection that provides weather protection,

More information

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

OWNER S MANUAL SERIES MDS-96-BK, SM, DR SERIES MDS-96-BK, SM, DR OWNER S MANUAL Introduction... 1 Bill of Materials... 2 Assembly Instructions. 3 Warranty....12 IMPORTANT NOTES, WARNINGS AND SAFETY INSTRUCTIONS Ensure that all employees understand

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details S1.0 Safety Anchor Plan Building 709 Bull Street Columbia, 1 10/13 T-1 (Title Page)

More information