Type of system: Hybrid Inverter Manufacturer s data. Type: Trina Energy Storage Solutions (Jiangsu) Co., Ltd. P Emax = 5000 W (TB5200TH)
|
|
- Amberlynn Dorcas Goodman
- 5 years ago
- Views:
Transcription
1
2
3
4 F.3 Requirements for the test report for power generation units (VDE-AR-N 4105) A.1 Requirements to the Test Report on Generation Units (DIN V VDE V ) Extract from the test report on the certificate of units Determination of electrical properties Type of system: Hybrid Inverter Manufacturer s data Manufacturer: Trina Energy Storage Solutions (Jiangsu) Co., Ltd. Type: Active Power: Rating voltage: TB5200TH 5 [kw] 400 [Vac] Measuring period: from to Active Power : P Emax = 5000 W (TB5200TH) Reactive power reference: Active power P/P n [%] Max. possible cosφ under-excited N/A N/A Max. possible cosφ over-excited N/A N/A Because of the limit of maximal apparent power output, the 100% real power can be reached only when cosφ=1. Compliance of required displacement factor cosφ: Default in system control 0.900O 0.920O 0.940O 0.960O 0.980O U 0.960U 0.940U 0.920U 0.900U Measured value at PGU terminals Above PF values are measured under 50%Pn output Reactive power transfer function Standard- cosφ (P) characteristic: Active power P/P n [%] cosφ N/A N/A Conform to Standard-cosφ (P) characteristic. Because of the limit of maximal apparent power output, the 100% real power can be reached only when cosφ=1. Switching actions Marking operation without default (to primary energy carrier) ki 0.4 Worst case at switch over of generator sections ki N/A Marking operation at reference conditions(of primary energy carrier) ki 1.0 Breaking operation at nominal power ki 1.0 Worst case value of all switching operations kimax 1.0 Flicker Angle of network impedance Ψk: Flicker coefficient of system flicker CΨ: 2.99 N/A N/A N/A The most unfavorable angle of network impedance approximately 32 was selected for testing. Page 1 of 5
5 Harmonics Active power P/P n [%] Harmonic number [%] [%] [%] [%] [%] [%] [%] [%] [%] [%] [%] Page 2 of 5
6 Intern-harmonics Active power P/P n [%] Frequency [Hz] [%] [%] [%] [%] [%] [%] [%] [%] [%] [%] [%] Page 3 of 5
7 Higher frequencies Active power P/P n [%] Frequency [khz] [%] [%] [%] [%] [%] [%] [%] [%] [%] [%] [%] Page 4 of 5
8 F.4 Requirement for the test report for the NS protection (VDE-AR-N 4105) A.2 Requirements to the Test Report on the NA Protection (DIN V VDE V ) Extract from the test report on the certificate of units Determination of electrical properties NS Protection as Central NA Protection Type of NS protection: Software version: Manufacturer: Measuring period: from YYYY-MM-DD to YYYY-MM-DD Other manufacturer s data Protection function Setting value Tripping value Tripping time NS protection a Voltage decrease protection U < 0.8 * U n * U n ms Voltage increase protection U > 1.1 * U n * U n ms Voltage increase protection U >> 1.15 * U n * U n ms Frequency decrease protection f < 47.5Hz Hz ms Frequency increase protection f > 51.5Hz Hz ms a. The tripping time comprises the period before limit violation U f until tripping signal to interface switch. During planning of power generation system the proper time of interface switch shall be added to the highest value of time determined above. The break time (sum of tripping time NS protection plus proper time of interface switch) should not exceed 200 ms. NS Protection as integrated NS Protection Type of NS protection: Software version: Manufacturer: Integrated NS protection Other manufacturer s data TB5200TH-V0.0.1 Assigned to PGU type: Hybrid Inverter Trina Energy Storage Solutions (Jiangsu) Co., Ltd. Measuring period: from to Integrated interface switch Type of switching equipment 1: Type of switching equipment 2: AC Relay AC Relay Protection function Setting value Tripping value Break time Voltage decrease protection U < 0.8 * U n L2:185.8 V L1:186.2 V L3:186.0 V L1:166 ms L2:171 ms L3:162 ms Voltage increase protection U > 1.1 * U n V < ms Voltage increase protection U >> 1.15 * U n L2:263.6 V L1:265.6 V L3:265.4 V L1:154 ms L2:144 ms L3:151 ms Frequency decrease protection f < 47.5Hz Hz 92 ms Frequency increase protection f > 51.5Hz Hz 94.4 ms Proper time of interface switch < 20 ms The break time (sum of tripping time NS protection plus proper time of interface switch) should not exceed 200 ms. The verification of the full function chain NS protection- Interface switch has yield to intended disconnection. Page 5 of 5
IECRE OPERATIONAL DOCUMENT
IECRE OD-551-16 Edition 1.0 2017-11-07 IECRE OPERATIONAL DOCUMENT IEC System for Certification to Standards relating to Equipment for use in Renewable Energy applications (IECRE System) Assessment of RETLs
More informationWIND TURBINES IN WEAK GRIDS CONSTRAINTS AND SOLUTIONS. J O G Tande and K Uhlen. SINTEF Energy Research, Norway SUMMARY
WIND TURBINES IN WEAK GRIDS CONSTRAINTS AND SOLUTIONS J O G Tande and K Uhlen SINTEF Energy Research, Norway SUMMARY Cost efficient utilisation of the wind energy resource requires wind farms to be located
More informationINSULATION MONITORING RELAIS
October 2010 RELAIS industrial applications for use in medical rooms e l e t t ro n i c a www..it RI se rie s The RI isolation monitor series, are designed to permanently monitor the isolation to earth,
More informationInterconnection Application
Interconnection Application Persons interested in applying for the interconnection of a distributed energy resource to the Utility s distribution system through the Fast Track or Study Processes are to
More informationTechnical Requirements for Distributed Generation Connection
Technical Requirements for Distributed Generation Connection Distributed Generation Connection Requirements SECTION 1: INTRODUCTION 1.1 General Purpose This document defines the requirements for connecting
More informationCONSIDERATIONS REGARDING THE OPTIMIZATION OF A RENEWABLE ELECTRICAL ENERGY GENERATION SYSTEM'S FUNCTIONING
Nonconventional Technologies Review Romania, June, 2017 2017 Romanian Association of Nonconventional Technologies CONSIDERATIONS REGARDING THE OPTIMIZATION OF A RENEWABLE ELECTRICAL ENERGY GENERATION SYSTEM'S
More informationSMALL GENERATOR INTERCONNECTION REQUEST (Application Form)
SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Attachment 2 Transmission Provider: Bluestem Electric Cooperative, Inc. Designated Contact Person: Kevin Heptig Address: P.O. Box 5, Wamego, Kansas
More informationDISTRIBUTED RENEWABLE ENERGY GENERATION POLICY
DISTRIBUTED RENEWABLE ENERGY GENERATION POLICY Dominica Electricity Services 2016 Version 2.00 DOCUMENT TITLE AND APPROVAL PAGE DOCUMENT NUMBER: 2016/002/D DOCUMENT TITLE: DISTRIBUTED RENEWABLE ENERGY
More informationENGINEERING RECOMMENDATION G83/2
MATERIALS & SAFETY - R&D TR20259 page 1 of 8 APPENDIX 4 TYPE VERIFICATION TEST REPORT GENERATING PLANT DETAILS Type Approval an manufacturer/supplier eclaration of compliance with the requirements of Engineering
More informationSession 13: German MV and LV Grid Code and PV/Wind Operating Experience
Session 13: German MV and LV Grid Code and PV/Wind Operating Experience Dr. Dipl.-Ing. Thomas Ackermann Energynautics GmbH t.ackermann@energynautics.com PV/Wind Operating Experience 2 German Energy Policy
More informationFeatures SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S
Type List Terminal style Quick terminal Contact form Designation Features A general purpose Power Relay. Contact rating up to 12A 250VAC (). Epoxy sealed type and flux free. Quick connect terminal or PCB
More informationDISTRIBUTED GENERATION AND POWER QUALITY
DISTRIBUTED GENERATION AND POWER QUALITY Arindam Ghosh Department of Electrical Engineering IIT Kanpur DISTRIBUTED GENERATION Distributed Generation (DG) employs smaller-size size generators. The electricity
More informationCONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING NETWORK SYSTEMS SECTION
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT NETWORK SYSTEMS SECTION SPECIFICATION EO-4133 REVISION 2 OCTOBER, 2006 GENERAL REQUIREMENTS
More informationFacility Interconnection Requirements
Facility Interconnection Effective 1/1/2016 1. Purpose Facility Interconnection Facility Interconnection (FAC-001-2) To avoid adverse impacts on the reliability of the Bulk Electric System (BES), RPU documents
More informationSUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A
SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M 981 310 / 01A ) (c) CIRCUTOR S.A. ----- CVM-SP & CVM-SP-RS485-C -------- --- Page No. 1 1.- MAIN FEATURES... 2 1.1.- Parameters measured and
More informationRenewable Energy Impact to Distribution Network Performance and Reliability. ENGR. ROBERTO D. ISIP JR. Head, Network Asset Planning, MERALCO
Renewable Energy Impact to Distribution Network Performance and Reliability ENGR. ROBERTO D. ISIP JR. Head, Network Asset Planning, MERALCO Presentation Outline 1. RE Integration and changes in the Electric
More informationMitigation of Voltage Rise Caused by Intensive PV Development in LV Grid
Mitigation of Voltage Rise Caused by Intensive PV Development in LV Grid PIOTR KACEJKO PAWEŁ PIJARSKI LUBLIN UNIVERSITY OF TECHNOLOGY LUBLIN, POLAND Photovoltaic sector in Poland low level of development
More informationISSN Vol.07,Issue.16, November-2015, Pages:
ISSN 2348 2370 Vol.07,Issue.16, November-2015, Pages:3181-3185 www.ijatir.org Improvement of Power Quality in A Grid Connected Induction Generator Based Wind Farm using Static Compensator K. YOSHMA 1,
More informationDEMONSTRATIVE PROJECT ON GRID-INTERCONNECTION INTERCONNECTION OF CLUSTERED PHOTOVOLTAIC POWER GENERATION SYSTEMS
DEMONSTRATIVE PROJECT ON GRID-INTERCONNECTION INTERCONNECTION OF CLUSTERED PHOTOVOLTAIC POWER GENERATION SYSTEMS New Energy and Industrial Technology Development Organization (NEDO) Demonstrative Test
More informationCENTRE FOR WIND ENERGY TECHNOLOGY CHENNAI INDIAN WIND GRID CODE
CHENNAI INDIAN WIND GRID CODE Rajesh Katyal Unit Chief, R&D Centre for Wind Energy Technology OVERVIEW NEED FOR INDIAN WIND GRID CODE Wind energy constitutes 6% of the installed capacity in the power scenario
More informationWind Farm Connection to Serbian Distribution Network - Austere Quality Requirements vs. More Economical Power Distribution
Wind Farm Connection to Serbian Distribution Network - Austere Quality Requirements vs. More Economical Power Distribution SAŠA MINIĆ, DRAGAN TASIĆ University of Belgrade University of Niš Institute Nikola
More informationKeysight 16380C Capacitance Standard Set
Keysight 16380C Capacitance Standard Set Operating Note Notices The information contained in this document is subject to change without notice. This document contains proprietary information that is
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 LED High Bay Light Model name(s): 502286##
More informationRenewable energy connection requirements in Spain April 2012
Renewable energy connection requirements in Spain April 2012 agustin.diaz@ree.es Challenges Red Eléctrica de España (REE) is the Spanish TSO Rapid growth of RES and intrinsic system characteristic (Iberian
More informationRecommended Hole Pattern: [mm]
Dimensions: [mm] 12,5 max. 6,5 max. 16,0 max. 25,0 min. 0,8 ±0,05 1,3 ±0,8 7,5 ±1,0 Recommended Hole Pattern: [mm] 1,3 Schematic: V O 0,9 7,5 Scale - 4:1 Electrical Properties: Properties Test conditions
More informationFAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.
FAST POWER FACTOR REGULATOR Computer-14df - xx - 144a INSTRUCTION MANUAL ( M 981 611 / 00A ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14f --------- Page 2 POWER FACTOR REGULATOR COMPUTER-
More informationDelaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw)
An applicant (Generator Owner) makes application to to install and operate a generating facility greater than 100 kw interconnected with the utility system. Section 1, Applicant Information Directly Interconnected
More informationDISTRIBUTED GENERATION INTERCONNECTION PROCEDURES. June 21, 2011
DISTRIBUTED GENERATION INTERCONNECTION PROCEDURES June 21, 2011 Adopted June 28, 2011 Page i TABLE OF CONTENTS I. GENERAL CONSIDERATIONS 1 II. III. IV. SMALL DISTRIBUTED GENERATOR RESOURCES A. Application
More informationSolar Eye User Manual
Solar Eye User Manual Edition JIANGSU EVER-SOLAR NEW ENERGY CO., LTD. Table of Contents 1. Introductions. 3 1.1 Packing List..4 1.2 Safety and Notes... 5 2. Product Installation... 6 2.1 Connection
More informationDOMESTIC COGENERATION OF HEAT AND ELECTRICITY
DOMESTIC COGENERATION OF HEAT AND ELECTRICITY Henrik Weldingh DEFU - Denmark 1 hw@defu.dk INTRODUCTION CHP, Combined Heat and Power, or Cogeneration of Heat and Power, is the simultaneous production of
More informationROCHESTER PUBLIC UTILITIES
ROCHESTER PUBLIC UTILITIES INTERCONNECTION REQUIREMENTS Distribution Connected Distributed Generation Systems (40kW 10MW) (Version 1.1) 1 Revision History Date Revision Description Version # Revised by
More informationAGREEMENT FOR CONNECTION TO [EASTERN /LONDON / SOUTH EASTERN] POWER NETWORKS PLC S DISTRIBUTION SYSTEM
AGREEMENT FOR CONNECTION TO [EASTERN /LONDON / SOUTH EASTERN] POWER NETWORKS PLC S DISTRIBUTION SYSTEM BETWEEN AND (1) [Eastern / London / South Eastern] Power Networks plc Company Number [02366906 / 03929195
More informationINSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.
INSULATION GUARD MEG-1000 (Code 2 28 981) INSTRUCTION MANUAL ( M 981 220 / 99A ) (c) CIRCUTOR S.A. ----- Insulation guard MEG-1000 -------- M - 981 220 --- Page nº 1 Insulation guard MEG-1000 1.- BASIC
More informationAgilent 16047D Test Fixture
Agilent 16047D Test Fixture Operation and Service Manual Third Edition Agilent Technologies Japan, Ltd. Agilent PN 16047-90300 May 2000 Printed in Japan Notices The information contained in this document
More informationProject Generator Verification and Implementation Plan for PRC-019-2, PRC and MOD Compliance Fall Workshop October 12, 2017
Project 2007-09 Generator Verification and Implementation Plan for PRC-019-2, PRC-024-2 and MOD-025-2 Compliance Fall Workshop October 12, 2017 Objectives Purpose for Project 2007-09 Generator Verification
More informationSimple operation and a built-in bypass function make the CSX series a pleasure to use with many benefits in a tidy package.
AuCom s CSX soft starters provide greater control over the starting and stopping of three phase motors. There are two product ranges: the CSX for a simple soft start control device, or the CSXi for an
More informationHRI-R22t series GENERAL FUNCTIONS AND OPERATORS - LEGENDA INSULATION MONITORING VERSIONS FOR USE IN MEDICAL ROOMS
HRI-R22t series GENERAL HRI-R22t series The device has similar characteristics of previous model but it s more cheap and it has less functions. There is measuring signalling and it is able to verify temperature
More informationGRID CODE COMPLIANCE TESTING OF RENEWABLES NEW REQUIREMENTS AND TESTING EXPERIENCES
GRID CODE COMPLIANCE TESTING OF RENEWABLES NEW REQUIREMENTS AND TESTING EXPERIENCES Nils Schäfer, Dr. Gunter Arnold, Wolfram Heckmann Fraunhofer Institute for Wind Energy and Energy System Technology Kassel,
More informationSeries Miniature Circuit Breaker Series residual current Circuit Breaker Series Disconnector
Series Miniature Circuit Breaker Series residual current Circuit Breaker Series Disconnector Company profile Founded in 1994 as a Sino-U.S. joint venture, Hongmei Electronic specializes in developing,
More informationImpacts of the Decentralized Wind Energy Resources on the Grid
21, rue d Artois, F-75008 PARIS CIGRE US National Committee http : //www.cigre.org 2013 Grid of the Future Symposium Impacts of the Decentralized Wind Energy Resources on the Grid Babak Enayati, PhD, Senior
More informationGrid Interconnection Issues for Wind Generation
Grid Interconnection Issues for Wind Generation NRECA APPA - DOE Teleconference December 8, 2005 By Thomas A. Wind, PE Wind Utility Consulting Jefferson, Iowa Topics I Will Cover What are the key technical
More informationINSULATION MONITORING RELAIS
October 2010 RELAIS industrial applications for use in medical rooms e l e t t ro n i c a www.contrel.it HRI series GENERAL Devices allow insulation monitoring for IT systems in medical use rooms, as well
More informationTable of Contents. User s Manual 1
Table of Contents User s Manual 1 Table of Contents Table of Contents 1 SECURITY ADVICE AND WARNINGS 4 1.1 Welcome -------------------------------------------------------------------------------------------------------------------------------------------
More informationCVM-BDM SERIES INSTRUCTION MANUAL
SUPPLY NETWORK ANALYZER CVM-BDM SERIES INSTRUCTION MANUAL ( M98153001-03 / 11A ) (c) CIRCUTOR S.A. ----- CVM-BDM supply network analyzer -------- --- Page Nº 1 USER'S MANUAL page 1.- BASIC INSTRUCTIONS...
More informationWIND ENERGY CONVERTERS AND SOME ASPECTS OF POWER QUALITY
RIO 3 - World Climate & Energy Event, -5 December 003, Rio de Janeiro, Brazil 349 WIND ENERGY CONVERTERS AND SOME ASPECTS OF POWER QUALITY R. E. Hanitsch*, D. Schulz Institute of Energy and Automation
More informationMEASUREMENTS AND SIMULATION FOR POWER QUALITY OF A WIND FARM
Research Article MEASUREMENTS AND SIMULATION FOR POWER QUALITY OF A WIND FARM 1 S.P. Shukla, 2 Sushil Kumar Address for correspondence 1 Department of Electrical Engineering, Bhilai Institute of Technology,
More informationPLCC Sockets Through Hole - M43 Series
Through Hole - M43 Series PART NUMBER LEGEND M43X-XX-XX NUMBER OF CONTACTS 20, 28, 32, 44, 52, 68, 84, 100 (-10 Style) 44, 52, 68, 84 (-11 Style) STYLE -10 Standard wall thickness, through hole -11 Thin
More informationISSN MIT Publications
MIT International Journal of Electrical and Instrumentation Engineering Vol. 1, No. 2, Aug 2011, pp 116-122 116 Power Quality Issues and its Improvement in Wind Energy Generation Interface to Grid System
More informationZero cross function. DIN track mounting *2. Screw mounting
Solid State Contactors for Heaters Three-phase CSM_Three-phase_DS_E_3_1 Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track
More informationSOLCAL. 1 digital regulator. 257 series CONTENTS INSTALLATION AND COMMISSIONING MANUAL. Function
28111.03EN www.caleffi.com SOLCAL 1 digital regulator Copyright 2013 Caleffi 257 series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function 1 Technical data Dimensions Wiring diagram 3 Functional characteristics
More informationEffects of Unbalanced Faults on Transient Stability of Cogeneration System
ffects of Unbalanced Faults on Transient Stability of Cogeneration System WI-NNG CHANG CHIA-HAN HSU Department of lectrical ngineering Chang Gung University 259 Wen-Hwa st Road, Kwei-Shan, Tao-Yuan, Taiwan,
More information3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B
3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M 981 198 / 00 B ) (c) CIRCUTOR S.A. -- MKB-363-M ELECTRONIC METERS -- M-981198 -- Page Nº 2 THREE-PHASE THREE-WIRE ACTIVE ENERGY ELECTRONIC
More informationPOWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.
POWER FACTOR REGULATOR Computer-12e-xx INSTRUCTION MANUAL ( M 981 606 / 02A ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 12e --------- Page 2 POWER FACTOR REGULATOR COMPUTER- 12e 1.- POWER
More informationWind turbine model validation with measurements
9 th Deep Sea Offshore Wind R&D Seminar, 19-20 January 2012, Trondheim Wind turbine model validation with measurements - Comparison between measured and simulated responses to voltage dips in the grid
More informationXSTREAM REMOTE PLASMA SOURCE WITH ACTIVE MATCHING NETWORK
XSTREAM REMOTE PLASMA SOURCE WITH ACTIVE MATCHING NETWORK FULLY INTEGRATED PLASMA SOURCE PLATFORM FOR HIGH-FLOW AND HIGH-PRESSURE, REACTIVE-GAS PROCESSES The high-efficiency Xstream platform, mounted outside
More informationDNVGL-SE-0124 Edition March 2016
SERVICE SPECIFICATION DNVGL-SE-0124 Edition March 2016 Certification of grid code compliance The electronic pdf version of this document found through http://www.dnvgl.com is the officially binding version.
More informationWE-UCF SMD Common Mode Line Filter
A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 khz/ 50 mv L 2x 0.013 mh ±30% Rated current T = 40 K I R 10.0 A max.
More informationWE-UCF SMD Common Mode Line Filter
A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 khz/ 50 mv L 2x 4.7 mh ±30% Rated current T = 40 K I R 0.75 A max.
More informationWE-UCF SMD Common Mode Line Filter
A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 khz/ 50 mv L 2x 0.32 mh ±30% Rated current T = 40 K I R 3.25 A max.
More informationFIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL
FIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL ( M 981 316 / 99B ) (c) CIRCUTOR S.A. ------ Power demand controller by energy pulses - CVM-R8D-CPP ---------- Page
More informationDistributed Renewable Energy Generation Interconnection Policy
Distributed Renewable Energy Generation Interconnection Policy Dominica Electricity Services 2010 Version Table of Contents Executive Summary... 2 1. Interconnection Policy... 6 1.1 Introduction... 6 1.2
More informationENERCON. Wind Farms with Power Plant Capabilities. Tokyo, October 27 th Werner Bohlen / Eckard Quitmann
ENERCON Wind Farms with Power Plant Capabilities Tokyo, October 27 th 2009 Werner Bohlen / Eckard Quitmann Slide 1 Subjects: 1. ENERCON technical concept 2. Operational ranges (U, f) 3. Steady state reactive
More information64-Channel Form C or Form A Switch
Agilent E1442A 64-Channel Form C or Form A Switch Data Sheet 1-Slot, C-size, register based Any combination of channels can be closed or opened Nonlatching armature relays External devices can be actuated
More informationCity of Santa Monica Building and Safety Division Submittal Requirements Expedited Solar Photovoltaic (10 kw or Less)
City of Santa Monica Building and Safety Division Submittal Requirements Expedited Solar Photovoltaic (10 kw or Less) Permits for One- and Two-Family Dwellings This following information is to guide applicants
More informationEC medium pressure axial fans.
EC medium pressure axial fans. The efficient system solution. The engineer s choice GreenTech EC technology in a new dimension. Thanks to these new new axial axial fans, fans, our our highly highly efficient
More informationFACILITY CONNECTION REQUIREMENTS NERC TO-FAC 001-0
FACILITY CONNECTION REQUIREMENTS NERC TO-FAC 001-0 TABLE OF CONTENTS (NERC TO-FAC-001-0) Facility Connection Requirements Introduction Procedures for Coordinated Joint Studies...1 Procedures for Notification...1
More informationCOMMISSION OF THE EUROPEAN COMMUNITIES. Working Document COMMISSION REGULATION../
COMMISSION OF THE EUROPEAN COMMUNITIES Brussels, XXX C(2011) YYY final Working Document COMMISSION REGULATION../ of [ ] amending Regulation (EC) 1275/2008 of 17 December 2008 implementing Directive 2005/32/EC
More informationTechnical Requirements for Connecting Distributed Generation NK8010
Technical Requirements for Connecting Distributed Generation Unison Networks Limited Approved Standard NK8010 Issue No. 1.0 Issue Date: 01/10/2009 New Standard Status: Draft ; In Service ; Under review
More informationStandard Development Timeline
Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard is adopted by the NERC Board of Trustees (Board).
More informationTRANSMISSION PLANNING ASSESSMENT METHODOLOGY AND CRITERIA
TRANSMISSION PLANNING ASSESSMENT METHODOLOGY AND CRITERIA For Compliance with NERC Reliability Standard: TPL-001-4 1/10/2017 Version: 4.2 Table of Contents 1 Revision and Approval History... 2 1.1 Revision
More informationAMOTECH SPECIFICATION MULTILAYER CHIP VARISTOR TYPE : AVLC 5S July 3, 2001 MULTILAYER CHIP VARISTOR SHEET 1/6 DESIGNED CHECKED APPROVED
SPECIFICATION MULTILAYER CHIP VARISTOR TYPE : AVLC 5S 02 050 July 3, 2001 CO., LTD. 17-2, JAMWON-DONG, SEOCHO-GU, SEOUL, KOREA TEL : 82-2-544-1351 FAX : 82-2-517-7183 DESIGNED CHECKED APPROVED MULTILAYER
More informationABSORPTION HYBRID FILTER FAR-Q TYPE
ABSORPTION HYBRID FILTER FAR-Q TYPE USER MANUAL Code M98206701-03-07A ------ Absorption filter ------ User Manual, M98206701-03-07A ------ Page 1 of 11------ CONTENTS 1.- BASIC INSTRUCTIONS... 2 1.1.-
More informationAbout power quality. Harmonics. Disturbances caused by harmonics
About power quality Our increased demand for quality and comfort of life have lead us to use more and more Industrial Automation, centralized and larger IT applications, Hi tech office and commercial buildings,
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2010-03-30 Page 1 of 12 Report Reference # E186249-A59-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment
More informationNPS/003/015 Technical Specification for 33kV, 66kV and 132kV Post Insulators
Version:- 3.1 Date of Issue:- June 2014 Page 1 of 13 NPS/003/015 Technical Specification for 33kV, 66kV and 132kV Post Insulators 1. Purpose This document is the technical specification for 33kV, 66kV
More informationRe: NOTICE OF APPLICATION NO , PROCEEDING ID. 162 ATCO ELECTRIC LTD. MICRO-GENERATION DETERMINATION
February 15, 2008 Raymond Lee AUC Regulatory Policy Division, Calgary Office Calgary, AB Email: raymond.lee@auc.ab.ca Re: NOTICE OF APPLICATION NO. 1604775, PROCEEDING ID. 162 ATCO ELECTRIC LTD. MICRO-GENERATION
More informationHybrid Wind-Diesel Generation System
Hybrid Wind-Diesel Generation System Apoorva Kanthwal 1 Department of Electrical & Electronics Engineering Chandigarh University, Mohali, India. apoorva2987@gmail.com Aman Ganesh 2 Department of Electrical
More informationSouthern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.
Southern California Edison Revised Cal. PUC Sheet No. 59933-E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No. 59625-E Rule 21 Sheet 7 A. TABLE OF CONTENTS Hh. Smart Inverter Generating
More informationGeneration Application Part B: Technical Form
Generation Connections Generation Application Part B: Technical Form For all applications with total installed generation capacity greater than 16A per phase (>4). 01 May 2018 How to fill out this application
More informationEC medium pressure axial fans. The efficient system solution.
EC medium pressure axial fans. The efficient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly efficient GreenTech EC technology is now available for
More informationUNINTERRUPTIBLE POWER SUPPLY MODEL 9800AE MULTI MODULE SYSTEM SPECIFICATIONS
UNINTERRUPTIBLE POWER SUPPLY MODEL 9800AE MULTI MODULE SYSTEM SPECIFICATIONS TABLE OF CONTENTS 1. GENERAL...2 1.1. SUMMARY...2 1.2. STANDARD...2 1.3. UPS MMS SYSTEM DESCRIPTION...2 1.3.1. Components...2
More informationUniversity of Strathclyde Faculty of Engineering
University of Strathclyde Faculty of Engineering Energy Systems and the Environment: Part A Examination Monday 19 January 2004 14.00-17.00, M329 Full-time students should attempt FOUR questions, 1 from
More informationDOMESTIC ELECTRICAL INSTALLATION PERIODIC INSPECTION REPORT (FOR A SINGLE DWELLING) B ADDRESS AND DETAILS OF THE INSTALLATION Address: SPECIMEN
A DETAILS OF THE CLIENT Client / Address: C PURPOSE OF THE REPORT Purpose for which this report is required: E PARTICULARS OF THE CONTRACTOR Trading Title: Address: DOMESTIC ELECTRICAL INSTALLATION PERIODIC
More informationISSN Vol.09,Issue.04, March-2017, Pages:
ISSN 2348 2370 Vol.09,Issue.04, March-2017, Pages:0558-0562 www.ijatir.org Simulation Exhibition of 220KW Wind Power Generation with PMSG Using Matlab Simulink K. INDRANI 1, DR. K. RAVI 2, S. SENTHIL 3
More informationCASE STUDY : ASSESSMENT OF POWER QUALITY IN PRACTICE
CASE STUDY : ASSESSMENT OF POWER QUALITY IN PRACTICE Jan RASMUSSEN Danish Energy Association Denmark jar@danskenergi.dk ABSTRACT Power quality has become an issue of interest for distribution network operators
More informationGemini Tech CO., LTD. PART NO. : GCB2002A-SFYLYHC06 FOR MESSRS. : GCB2002A-SFYLYHC06 PAGE: 1/17 CONTENTS
Gemini Tech CO., LTD. CONTACT ADDRESS : RM,1521 Investel, 1123-2 Sanbon-dong, Gunpo-city, Kyeongki-do, 435-040 Korea Tel: +82-31-455-3200 Fax: +82-31-343-2102 E-mail: sales@findlcd.com PART NO. : FOR MESSRS.
More informationVariable Renewable Energy Sources in Distribution Networks Martin Braun Fraunhofer IWES & Universität Kassel
Variable Renewable Energy Sources in Distribution Networks Fraunhofer IWES & Universität Kassel 1st International Conference on Large-Scale Grid Integration of Renewable Energy in India New Delhi, India
More informationELECTRIC SYSTEMS PROCEDURE: ES DISTRIBUTED ENERGY RESOURCES (DER)
n ELECTRIC SYSTEMS PROCEDURE: ES 20202 902 DISTRIBUTED ENERGY RESOURCES (DER) TITLE: Parallel Operations & Interconnection of DER Facilities on the Distribution System CREATION DATE: REVISED DATE: October
More informationPower Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing
Switch Mode Power Supply (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function
More informationSPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL CUSTOMER. MODEL NO. BPHE010C701-50 PART NO. LKBPHE010C701-P1-01 MODEL NAME. 10W 15V 700mA LED Driver DATE. 2010/01/15 APPROVED SIGNATURES (Taiwan Headquarter) 5F,NO.127, Lane
More informationSECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENTS AND QUANTITIES
Bihar State Electricity Board Bharat Heavy Electricals Ltd. 220 /132 kv Pusauli Substation & Dehri Extension Doc. No. TB-357-316-001, Rev 00 Technical Specification of 245kV & 145 kv Circuit Breaker SECTION
More informationDirect Liquid Cooling IGBT Module for Automotive Applications
Direct Liquid Cooling IGBT Module for Automotive Applications Takahisa Hitachi Hiromichi Gohara Fumio Nagaune ABSTRACT A compact insulated gate bipolar transistor (IGBT) module with low thermal resistance
More informationINTERCONNECTION APPLICATION AND AGREEMENT
INTERCONNECTION APPLICATION AND AGREEMENT With Terms and Conditions for Interconnection For a Level 1 Review (Certified Inverter-based Units under 10kW) Mailing Address PSE&G Net Metering 750 Walnut Avenue
More informationEvaluation of measuring methods for flicker emission from modern wind turbine
Evaluation of measuring methods for flicker emission from modern wind turbine Leif S. Christensen ), Poul E. Sørensen ), Troels S. Sørensen ), Henny K. Nielsen ) ) DELTA Dansk Elektronik, Lys & Akustik,
More informationPower Management Solutions Exploring Hidden Cost Opportunities
Power Management Solutions Exploring Hidden Cost Opportunities Stephen Barker Head Of Energy Efficiency & Environmental Care Siemens plc, Industry Sector UK Siemens AG, 2010 All Rights Reserved Agenda
More informationBETA Low-Voltage Circuit Protection
Siemens AG 9 BETA Low-Voltage Circuit Protection Characteristic curves for fuses and information on configuration for catalog ET B1 Catalog Add-On ET B1 AO 9 & # # # Answers for industry. Siemens AG 9
More informationPower Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing
Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function
More informationMULTI-PURPOSE THREE PHASE METER
MULTI-PURPOSE THREE PHASE METER CIRWATT Series (Version 3.xx) Installation Manual (M98165601-03 / 04A) (c) CIRCUTOR S.A. ---- Installation Manual ------------------------ CIRWATT ----------- Page No. 1
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2015-09-29 Page 1 of 14 Report Reference # E182560-V4-S20 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment
More information