Danfoss and Controls for CO2

Size: px
Start display at page:

Download "Danfoss and Controls for CO2"

Transcription

1 Danfoss and Controls for CO2 CO 2 Department (slide master) Optional text Date 1

2 Controllers for various CO2 applications Some examples of Danfoss controllers suited for CO2: AK-PC781 High-end multipurpose pack controller, incl.heat Reclaim, High pressure ctrl, parallel compressor, etc. AK-PC783 High-end cascade controller, incl. Heat Reclaim, high pressure ctrl, etc. AK-PC772 High-end limited to 3+2 compressors, 2 suction group controller, limited HR, parallel compressor, etc. Intended for small to medium sized supermarkets AK-CC550A FR-inject algorithm specially suited for CO2, Date

3 AK-PC781 AK-PC 781 shown in CO2 trans-critical booster system (MT/LT/IT) Control of one suction group including unloaders and speed! Condenser pressure control or gas cooler fan control! Gas cooler control! Gas by-pass! IT Parallel compression Tap water reclaim! Heat reclaim! Oil management and control! Date

4 AK-PC772 All transcritical control functions are integrated in AK-PC772 Heat Reclaim with optimum high pressure control based on actual indoor temperatures Optimum compressor capacity control via FC 103 (or digital scroll) Second suction group capacity control Receiver pressure ctrl by CCM Optimum pressure in Gas Cooler by CCMT or ICMTS Optimum media temperature out of Gas Cooler via FC 103 or EC-Fan Date

5 AK-PC783 CO 2 for both MT and LT with HFC on top Date

6 Improved surveillance using Service Tool - AK-PC781 Click on an icon and you will get see next slide! Date

7 Status and overview - Two Suction groups MT LT Date

8 Ease of use improved - Smart Settings Smart Settings allow fast setup of complex high pressure settings. Select just one Smart value for the High Pressure side, approx. 15 bar below Safety Valves, and the rest of parameters are calculated. Select just one Smart value below the receiver design pressure, to do the second calculation. Unused functions are hidden. E.g. if you deselect Receiver. Values can be changed after calculation, if preferred. Date

9 Floating fan control with Sc3 and Sgc temperature sensors Ref (for Sgc) temp. = Sc3 + tm + (dim-tm x cap/100) Sgc reference is mostly 2K above ambient temperature as dim and tm is set to equal values Sgc_Ref: ( Sc3 + 2K ) PI Fan capacity Sgc Date

10 Condenser improvements Improved floating condenser set point function compared to former AK-PC 780 Rule of thumb indicates 3 % energy savings on every 1 K on the condenser. condensing temp above Amb Condensing temp Compr Cap Energy savings compared to PC780 [%] Most compressor run time hours are in the 15% - 50% range PC780 PC Compr cap % Energy Savings % (Improved K) Date

11 Sub-critical vs. trans-critical CO 2 P [bar] 10 2 Subcritical Transcritical ,2 0,4 0,6 0, h [kj/kg] A trans-critical booster system can run both sub- and trans-critical. At lower temperatures than 31ºC the system runs sub-critical with a very good COP. At temperatures higher than the critical temperature (31ºC) CO 2 cannot condense therefore the system must run trans-critical with poorer COP as consequence In warmer climates a cascade system is often preferred because it has an advantage here. Cascade system has an extra cooling circuit, which can be used to cool the CO 2 circuit in order to keep the pressure down in this way avoiding trans-critical operation. Date

12 Integrated High Pressure controller Features: Maintain optimal COP in trans-critical areas Maintain optimal sub cooling in subcritical areas Safe transition between trans-critical and subcritical operation Optimum COP gas cooler control using the ICMTS or CCMT valve, Vhp Control of receiver pressure using the CCM (or ETS) valve, Vrec Heat reclaim with by pass of Gas Cooler, V3gc Use of radiometric pressure transmitters Supports 60, 100 and 160 bar pressure transmitters AKS 2050 Improved EKC 326a functionality Date

13 Benefits of integrated High Pressure controller High pressure systems can maintain either maximum COP or maximum system capacity for any given ambient condition Intermediate pressure is controlled independently and maintained on the required level All valve positions, measured temperatures and pressures are visible on the controller (one device) If required by Heat Recovery demand, the high pressure can be changed. Changeover is only allowed if several conditions are fulfilled, which makes a safe system (flow, temperatures, pressures, timers). A safe High Pressure operation has priority over other functions. Trans-critical optimum is a curve made by several tests and measurements Gas cooler pressure [bar] Date Refrigerating capacity [kw] and COP [-] New See Next COP QE OPERATING CONDITION t E = -10 C, t SH = 10 K t GC,OUT = 35 C

14 Optimal high pressure on trans-critical CO 2 COP = 1.90 COP = 2.31 COP = 2.28 h EVAP h COMP Date

15 Trans-critical vs. sub-critical CO 2 Date

16 Trans-critical vs. sub-critical CO C on gas leaving gas cooler Date

17 High Pressure system The Smart Settings make it easy to setup several HP settings by entering a single number. See Bold numbers and fig. Design criteria define levels. Safety valve and cut out switch ICMTS valve has 140 bar working pressure (0-10V control) CCMT valve has 140 bar working pressure (Stepper control) 120 bar Design pressure and setting of safety valve 115 bar High pressure switch cut-out (compressors) 103,5 bar Pc max limit (safety on Pack/Rack) 3 bar 100,5 bar Pc max start to make capacity reduction 100 bar Pgc Max, High pressure valve 100 % open 3 bar Pgc max. limit P-band 97 bar Pgc max. limit P-band where valve start to be forced open * Was in T in EKC 326, now in P Date

18 Maximum and minimum receiver pressure safety Date

19 Hot gas dump MT Pack Configuration Use hot gas dump Select whether hot gas should be supplied if the receiver pressure falls too low Prec hot gas dump Receiver pressure at which hot gas is turned on Prec gas dump diff. Difference at which hot gas is turned off again Date

20 Heat reclaim with CO 2 CO 2 has some excellent properties which can be utilized in heat reclaim High temperatures of the gas on the compressor outlet High enthalpy on the gas on the compressor outlet High density Good heat conductivity Heat reclaim can really be utilized above the critical temperature because gas rejects heat at higher temperatures with steady reduction in temperature through the heat exchanger. Above the critical temperature pressure and temperature can be controlled individually, which is an advantage in connection with heat reclaim. Date

21 Heat reclaim with CO 2 Demand for Heat Reclaim becomes more and more relevant due to rising energy costs. CO 2 applications are getting well known in Food Retail or Industrial systems and they run both subcritical and trans-critical. High discharge temperatures for CO 2 compression cycle is normal, often > 70 ºC This provide hot tap water (typically around 60 ºC) And low temperature heating for floor heating, radiators, air unit heater, etc. The Heat ratio is often x10 between hot tap water and heating A superior control strategy is necessary! 5 ºC 80 Bar 40 Bar T ºC MT -10 ºC 35 ºC Hot Tap Water x1 kwh Heating x10 kwh/day Energy Ratio, kwh 70 ºC 90 ºC Date

22 Achieving higher discharge temperatures The gas cooler rejects heat from the evaporator and compressor work In practice temperatures between ºC even with minimum compressor load can be achieved Heat reclaim between 25 and 65 ºC gives only a limited amount of heat If Pgc is raised when demand is present temperatures will increase to ºC Heat reclaim down to 25 ºC can now reject a large amount of heat The gas cooler will then only reject a small part of the heat Only little extra compressor work is needed! Log P 80 Bar 40 Bar -10 ºC 5 ºC 40 ºC 25 ºC water return Gas Cooler Heat to Gas Cooler MT -10 ºC Heat Reclaim Heat to Evaporator Heat Reclaim Work to Compressor Simplified CO2 refrigeration cycle 65 ºC 95 ºC h Date

23 Two stage Heat Reclaim integrated Features Control of hot Tap Water temperature Control of additional Heat reclaim source e.g. floor heating By pass valve for TW, HR and Gas Cooler Additional input (0-10V) from up to 5 heat consumers VSD (AKD, 0-10V) control of fans and water pumps to control water temperature Independent control of each subsystem, including safety conditions Date

24 Heat Reclaim There are 4 different heat reclaim control solutions in the system: Hot tap water Heat Reclaim, no HP offset (Pgc) Heat Reclaim, fixed HP offset Heat Reclaim, variable HP offset and Gas Cooler by-pass Log P 80 Bar 5 ºC 40 ºC water return TW 25 ºC water return HR Gas Cooler Heat reclaim Hot Tap Water Offset 40 Bar Pgc Heat Tap water 95 ºC This makes it possible to reclaim almost all heat and provide sufficient heat to most supermarkets in order to cover ALL the heat demand! -10 ºC MT -10 ºC h Date

25 Tap Water and Max Heat Reclaim mode Max Heat reclaim mode will control Pump speed Variable reference offset (Pgc) AND reduce fan speed AND finally gas cooler by-pass Up to 5 different heat consumers can give their reflected heat demand by a 0-10V signal, and the highest will determine the load on the system. The Ultimate heat reclaim is when Gas Cooler is by-passed. This will result in the red line. Which will increase running compressor capacity thus generating more heat. COP is decreased close to 1. Log P Gas Cooler by-pass = increasing compressor running capacity 80 Bar Offset 40 Bar -10 ºC 5 ºC 20 ºC water return HR Gas Cooler 40 ºC Heat reclaim Hot Tap Water Pgc MT -10 ºC Heat consumers 0-10V signal: 0-2 V: Variable pump speed 1-6 V: Variable offset (Pgc) 5-8 V: Reduce fan speed 7-10 V: By-pass gas cooler. Heat reclaim Hot Tap Water Heat Tap water 95 ºC h Date

26 Values Same energy efficiency (COP) as traditional HFC refrigeration systems CO2 does not effect the ozone layer CO2 has up to times lesser direct emission impact on global warming compared with traditional HFC refrigerants Produce high temperature tap water. (over 55 ºC/130 ºF) Produce heat in the store instead of rejecting the heat to the ambient Just one integrated electronic controller doing: Compressor and condenser capacity control High pressure control as well as heat recovery (CO2) Oil management and multi speed control (Compressor, fan, pump) Proven reliability of ADAP-KOOL controllers This controller is essential to make trans-critical systems work All former HFC functions are still available (as in AK-PC 740/780) Date

27 CO2 and Heat reclaim in Supermarkets White paper can be found in DILA 1. Save energy in your Supermarket with a CO2 Refrigeration system 2. Highly efficient heat reclaim with CO2 Two stage Heat Reclaim 1. Hot Tap Water, with 3-way valve 2. Heat Reclaim, with 3-way valve Save 10% on CO2 How to make Heat Reclaim Date

28 AK-CC 550A Case controller New functions in AK-CC 550A compared with AK-CC 550 S1 has been deleted Injection is controlled using Pe (Po) & S2 New Injection algorithm (FR-Inject) * Adaptive Defrost with skip function * The opening degree is reduced more rapidly, if liquid is detected after the Evaporator or low SH. Security function ensures that the valve closes if the SH get below the set limit. Department (slide master) Optional text Date 28

29 SS U RE NS MITT ER AKS 33 0G Pe : bar ps ig / MW P 5 80 p sig V d.c m A + SU PP LY VO LTA GE - C O MMO N AK-CC 550A Case controller FR inject function The superheat is reduced until the signal becomes unstable. Search speed is 0,25 K per 8 minutes. Then superheat is increased a bit until stability is found followed by a new reduction, and so on! AKV 10 S2 P e SH = S2 - T e Superheat in K TIME Superheat set point Actual superheat Department (slide master) Optional text Date 29

30 AK-CC 550A Case controller FR inject function Advantages: Integrated solenoid valve Adaptive adjustment Optimum utilisation at all load conditions Insensitive to operation conditions Compensate low Pc with higher opening degree Typical 5 10 % energy savings (TEV s are not available for CO 2 ) Superheat set point Actual superheat Department (slide master) Optional text Date 30

31 AK-CC 550A Case controller Evaporator design CO 2 has different properties than other refrigerants due to the high pressure Density of the gas is approximately 3 to 10 times higher than conventional refrigerants and therefore getting gas velocities high enough is a problem in evaporators Pressure drop has only very little influence on the evaporation temperature Long pipes in one sling gives long reaction time for the control Use small diameter and a pressure drop of ½-1 bar. Avoid long pipes To low velocity and surface is dry High velocity and wet surface Date

32 Refrigeration performance, ADAP-KOOL Value ADAP-KOOL monitoring modules AK-LM 350 AK-LM 340 AK-LM 330 Application Temperature monitoring Multi purpose ctrl COP monitoring Date

33 Refrigeration performance, ADAP-KOOL AK-LM 3xx function overview AK-LM330 AK-LM340 AK-LM350 Thermostats w. defrost interlock Pressostats functions Voltage input functions Digital alarm input functions Utility / Pulse meter input functions Alarm relay outputs PI controls advanced 10 Thermostat w. 2 sensor inputs 10 Temperature alarms 10 Difference thermostat 10 Differential pressostat 10 Pressure alarms 10 COP monitoring - CO2 boost, / cascade/one stage 1 Department (slide master) Optional text Date 33

34 Refrigeration performance, ADAP-KOOL Why COP and what is it? How can we measure if a refrigeration works good enough? Can we compare refrigeration plants, regarding energy consumption? COP = Obtained _ energy Used _ Power Are there any useful key numbers for refrigeration plants? Department (slide master) Optional text Date 34

35 Refrigeration performance, ADAP-KOOL What is an ideal COP? When calculating a COP for a refrigeration, it is possible to calculate an ideal COP, which can never be achieved. But, calculating the ratio between actual COP and ideal COP, tells how efficient the refrigeration plant is. Qo is the cooling removed at the MT level, and the ideal power consumption is calculated! When trimming/optimizing the refrigeration plant, one should try to lift the actual COP as much as possible! COP MT, Ideal = Q Power 0, MT MT, ideal Department (slide master) Optional text Date 35

36 Refrigeration performance, ADAP-KOOL What is an ideal COP? When calculating a COP for a refrigeration, it is possible to calculate an ideal COP, which can never be achieved. But, calculating the ratio between actual COP and ideal COP, tells how efficient the refrigeration plant is. Qo is the cooling removed at the MT level, and the ideal power consumption is calculated! When trimming/optimizing the refrigeration plant, one should try to lift the actual COP as much as possible! COP MT, Ideal = Q Power 0, MT MT, ideal Department (slide master) Optional text Date 36

37 Refrigeration performance, KPIs KPIs Service tool picture from a live installation. As can be seen various averages is calculated - 1 minute - 1 hour - 24 hour - All data can be collected by ADAP- KOOL system. Please NOTE: Valid flag (OK) shows if calculation is valid. One should calculate how many % valid data is present. If Valid % data > 70%, plant is stable and performing If Valid % data < 50%, you need to investigate, and COP could also be low Date

38 Frontend Comparing Supermarkets When it is possible to provide data from the supermarkets, it is possible to evaluate: Planteffic iency = COP COP actual Ideal Power consumption Energy consumption Costs Heat reclaim Operating patterns Plant efficiency Cooling load pr. M display case Date

39 Frontend Comparing Supermarkets Whats the reason for the low plant performance? And just as important: What is the cost of low plant efficiency? The cost of TOO low performance for inst.2 is calculated to: App. 336 Euro pr week Note: Depends upon prices for electricity at varoius geographical sites, and size of supermarket. AND..valve lifetime is degrading fast AND...compressors is switching fast, thus wearing down faster. Date

40 Refrigeration performance, reports Important info from COP Below table is a report generated in Danfoss Demo tool, on 4 actual supermarkets. Different info is available: - Potential savings pr day - Percent valid calculations(very important because it indicates if there is loose sensors, bad settings in controllers, etc, below 70% it could be necessary to check the plant) - COP for individual sites(should be at a certain level) Shop City Plant efficiency Pot. Savings pr day kwh P-MT [kw] P-LT [kw] COP-MT COP-LT Pct Valid Shop1 City Shop2 City Shop3 City Shop 4 City Department (slide master) Optional text Date 40

41 End Date

High efficient heat reclaim with CO2

High efficient heat reclaim with CO2 High efficient heat reclaim with CO2 Refrigeration systems with transcritical CO 2 has been taking market shares the last years. Since 2007 the market in Denmark has turned from conventional refrigeration

More information

Danfoss the pioneer in electronic expansion valve control

Danfoss the pioneer in electronic expansion valve control Technical paper Danfoss the pioneer in electronic expansion valve control When Danfoss introduced it s first microprocessor based ADAP-KOOL controller back in 1987 it was also the first controller with

More information

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP) Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low (LP) Danfoss Multi Ejector Solution TM, consists of a CTM 6 Low valve and an AK-PC 782A controller. This solution makes CO

More information

Multi Ejector Solution Transcritical CO 2 refrigeration systems in all climates

Multi Ejector Solution Transcritical CO 2 refrigeration systems in all climates Multi Ejector Solution Transcritical CO 2 refrigeration systems in all climates Mark Sever, Technical Manager 1 Danfoss Cooling Multi Ejector Solution The CO 2 development First, second, and third generation

More information

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP) Data sheet Multi Ejector Solution TM for R744 (CO 2 ) - CTM 6 High (HP) Multi Ejector Solution TM, consists of a CTM 6 High valve and an AK-PC 782A controller. This solution makes CO 2 refrigeration systems

More information

CO2 solutions February 2018

CO2 solutions February 2018 CO2 solutions 27-28 February 2018 Summary Overview of regulations Overview of Rivacold solution CO2 carbon dioxide CO2 Rivacold solution Case History 2 1. Overview of regulations Overview of regulations

More information

Type CTM 6 High Pressure (HP) and Low Pressure (LP)

Type CTM 6 High Pressure (HP) and Low Pressure (LP) Application guide How to design a transcritical CO 2 system with Multi Ejector Solution. Type CTM 6 High Pressure (HP) and Low Pressure (LP) www.danfoss.com Table of content What is the Multi Ejector Solution?

More information

YEARLY SIMULATION OF CO 2 REFRIGERATION SYSTEMS FOR SUPERMARKET APPLICATIONS

YEARLY SIMULATION OF CO 2 REFRIGERATION SYSTEMS FOR SUPERMARKET APPLICATIONS YEARLY SIMULATION OF CO 2 REFRIGERATION SYSTEMS FOR SUPERMARKET APPLICATIONS FRASCOLD SPA FRASCOLD SpA! Italy (1936)! Frascold USA! (2014)! Frascold Shanghai! (2014)! Frascold India! (2012)! Sales office!

More information

One. Discover the opportunities of CO 2. refrigeration. refrigerants.danfoss.com/co2. Brochure Natural refrigeration. Safe Efficient - Green

One. Discover the opportunities of CO 2. refrigeration. refrigerants.danfoss.com/co2. Brochure Natural refrigeration. Safe Efficient - Green Brochure Natural refrigeration Discover the opportunities of refrigeration Safe Efficient - Green One natural and efficient system for all your cooling and heating needs refrigerants.danfoss.com/co2 Why

More information

THE INSTITUTE OF REFRIGERATION

THE INSTITUTE OF REFRIGERATION Advance Proof. Private to members Copyright 2009 The Institute of Refrigeration No publication or reprinting without authority THE INSTITUTE OF REFRIGERATION Living without HFCs The Danish Experience by

More information

Refrigeration System with Booster Hot Gas Bypass in Tropical Climate

Refrigeration System with Booster Hot Gas Bypass in Tropical Climate Journal of Physics: Conference Series PAPER OPEN ACCESS Simulation of Transcritical CO 2 Refrigeration System with Booster Hot Gas Bypass in Tropical Climate To cite this article: I D M C Santosa et al

More information

COP Improvement Of A CO2 Refrigeration System With An Expander-Compressor-Unit (ECU) In Subcritical And Transcritical Operation

COP Improvement Of A CO2 Refrigeration System With An Expander-Compressor-Unit (ECU) In Subcritical And Transcritical Operation Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 COP Improvement Of A CO2 Refrigeration System With An Expander-Compressor-Unit

More information

24/7 monitoring and supervision of your system

24/7 monitoring and supervision of your system Overview Brochure ADAP-KOOL System Managers Achieve your energy goals with the best control and system management for Food Retail 24/7 monitoring and supervision of your system food-retail.danfoss.com

More information

Trends in Refrigeration System Architecture and CO 2. Andre Patenaude Emerson Climate Technologies

Trends in Refrigeration System Architecture and CO 2. Andre Patenaude Emerson Climate Technologies Trends in Refrigeration System Architecture and CO 2 Andre Patenaude Emerson Climate Technologies What s Hot in Supermarket Refrigeration? MT Cases With Doors LED Lighting Low Condensing ECM Fan Motors

More information

CO2 refrigeration and Its applications. Benoit Rodier, P.Eng.

CO2 refrigeration and Its applications. Benoit Rodier, P.Eng. CO2 refrigeration and Its applications Benoit Rodier, P.Eng. History of CO 2 Transcritical Cycle CO 2 Peak period of CO 2 First usage of CO 2 as a refrigerant (Alexander Twining,British patent) J&E Hall

More information

CO 2 the natural refrigerant for MT and LT in discounters, super- and hypermarkets PE4, Bernd Heinbokel

CO 2 the natural refrigerant for MT and LT in discounters, super- and hypermarkets PE4, Bernd Heinbokel CO 2 the natural refrigerant for MT and LT in discounters, super- and hypermarkets 18.08.09 PE4, Bernd Heinbokel AGENDA 1 Legislation in Europe, trends Comparison of refrigerants Overview on subcritical

More information

Variable Speed Solutions. Outstanding performance for residential applications

Variable Speed Solutions. Outstanding performance for residential applications Variable Speed Solutions Outstanding performance for residential applications Heat pumps - an efficient technology using renewable energy Environmental impact, reduction of carbon footprint and energy

More information

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION Available range Unit type IH Heat pump IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS

More information

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 An Integrated Solution for Commercial AC Chillers Using Variable Speed

More information

Cold Plate economy and ecology in supermarkets

Cold Plate economy and ecology in supermarkets Cold Plate economy and ecology in supermarkets ColdPlate Cold Plate efficiency Environmental and commercial support Many synthetic refrigerants have unwanted global warming and ozone depletion effects,

More information

Variable Speed Solutions Outstanding Performance For Heat Pump Applications

Variable Speed Solutions Outstanding Performance For Heat Pump Applications Variable Speed Solutions Outstanding Performance For Heat Pump Applications Your Choice For An Efficient Heating Solution Emerson Climate Technologies offers a wide selection of products from single components

More information

COP-OPTIMISED PRESSURE CONTROL FOR A CENTRALISED CO 2 COOLING SYSTEM IN AIRCRAFT APPLICATIONS

COP-OPTIMISED PRESSURE CONTROL FOR A CENTRALISED CO 2 COOLING SYSTEM IN AIRCRAFT APPLICATIONS COP-OPTIMISED PRESSURE CONTROL FOR A CENTRALISED CO 2 COOLING SYSTEM IN AIRCRAFT APPLICATIONS S. ADEYEFA, O. SCHADE, U. CARL Hamburg University of Technology, Department of Aircraft Systems Engineering

More information

Postprint. This is the accepted version of a paper presented at 13th IIR Gustav Lorentzen Conference.

Postprint.   This is the accepted version of a paper presented at 13th IIR Gustav Lorentzen Conference. http://www.diva-portal.org Postprint This is the accepted version of a paper presented at 13th IIR Gustav Lorentzen Conference. Citation for the original published paper: Raka Adrianto, L., Grandjean,

More information

Air Cooled Chiller (50Hz) Air Cooled Scroll. Air Cooled Screw ACC 05/15

Air Cooled Chiller (50Hz) Air Cooled Scroll. Air Cooled Screw ACC 05/15 ir Cooled Chiller (50Hz) ir Cooled Scroll ir Cooled Screw CC 05/15 ir Cooled Scroll Chiller ir Cooled Scroll Chiller - Product Lineup No Model Heat Compressor Electrical exchanger quantity(pcs) Maximum

More information

CAREL & CO 2 Technology!

CAREL & CO 2 Technology! CAREL &! CO 2 Technology!!!!!!!!!!!!!!!!!!!!!!!!!!Global&Key&Account&Manager&& &&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&Retail!! Agenda CAREL CO 2 Experience Advanced CO 2

More information

Air Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants

Air Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Bitzer TM s 404A and 507 Refrigerants 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Standard

More information

Industrial Heat Pumps

Industrial Heat Pumps IEA Meeting Technological Institute, Aarhus, Denmark Industrial Heat Pumps If the you can read this Click on the icon to choose a picture or Reset the slide. To Reset: Right click on the slide thumbnail

More information

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that.

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that. Set Free Modular FSXN Engineering for tomorrow. And the tomorrow after that. 0 03 Introducing a new addition to Hitachi s Set Free range of VRF air conditioning units - enhancing efficiency and user experience

More information

Enhanced Refrigeration Solutions. CMPX Show Thursday March 19 th,2014

Enhanced Refrigeration Solutions. CMPX Show Thursday March 19 th,2014 Enhanced Refrigeration Solutions Andre.Patenaude@emerson.com Director of Marketing, CO2 Business Development CMPX Show Thursday March 19 th,2014 Enhanced Refrigeration Solutions Enhanced Refrigeration

More information

Application Of Oil Flooded Compression With Regeneration To A Packaged Heat Pump System

Application Of Oil Flooded Compression With Regeneration To A Packaged Heat Pump System Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 14 Application Of Oil Flooded Compression With Regeneration To A Packaged Heat

More information

a comparative study of secondary glycol and direct expansion refrigeration systems

a comparative study of secondary glycol and direct expansion refrigeration systems a comparative study of secondary glycol and direct expansion refrigeration systems Second Nature Medium-Temperature secondary systems have been widely applied in commercial refrigeration since their introduction

More information

CO 2 Transcritical Cycle for Ground Source Heat Pump

CO 2 Transcritical Cycle for Ground Source Heat Pump CO 2 Transcritical Cycle for Ground Source Heat Pump.Ma Yitai, professor, Thermal energy research institute of Tianjin University, Tianjin, China Wang Jinggang, PhD student, Thermal energy research institute

More information

Natural refrigerants, a complete solution Latest technological advancements for warm climates

Natural refrigerants, a complete solution Latest technological advancements for warm climates Natural refrigerants, a complete solution Latest technological advancements for warm climates Prof. Dr. Armin Hafner No 7491 Trondheim Norway E mail: armin.hafner@ntnu.no Introduction The revival of natural

More information

Integration of the hidden refrigeration capacity as a heat pump in smart energy systems

Integration of the hidden refrigeration capacity as a heat pump in smart energy systems Integration of the hidden refrigeration capacity as a heat pump in smart energy systems Torben Funder-Kristensen This presentation outlines the concepts behind the Danish EUDP-project (64016-0106) Super

More information

Design and development of a residential gas-fired heat pump

Design and development of a residential gas-fired heat pump Design and development of a residential gas-fired heat pump Edward A Vineyard a*, Ahmad Abu-Heiba a, Isaac Mahderekal b a Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN, 37831, USA

More information

Trends in Refrigeration System Architecture and CO 2. Derek Gosselin Hillphoenix

Trends in Refrigeration System Architecture and CO 2. Derek Gosselin Hillphoenix Trends in Refrigeration System Architecture and CO 2 Derek Gosselin Hillphoenix Impact of Systems Architecture Refrigerants Impact on the Environment Different Types of System Architectures Energy s Impact

More information

Performance Comparison of Air-source Heat Pumps Using Economizer Vapor Injection and Internal Heat Exchanger in Cold Regions

Performance Comparison of Air-source Heat Pumps Using Economizer Vapor Injection and Internal Heat Exchanger in Cold Regions Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Performance Comparison of Air-source Heat Pumps Using Economizer Vapor

More information

Compressed Air. How to Justify Projects and Achieve Significant Savings in Multiple Compressor Environments

Compressed Air. How to Justify Projects and Achieve Significant Savings in Multiple Compressor Environments Compressed Air How to Justify Projects and Achieve Significant Savings in Multiple Compressor Environments Tom Sherman, CEM, CDSM PCX Energy Services, LLC Justifying Projects KEY: Reduce/Eliminate Perceived

More information

Heat Pump Hot Water Supply Systems

Heat Pump Hot Water Supply Systems 2007年度版 Heat Pump Hot Water Supply Systems (1) Aims A great amount of energy is consumed for supplying hot water in the residential, commercial and industrial sectors. emission from residential hot water

More information

Copeland Transcritical 4MTLS CO 2 Compressors. June 2016

Copeland Transcritical 4MTLS CO 2 Compressors. June 2016 Copeland Transcritical 4MTLS CO 2 Compressors June 2016 (i-pro CO2 ) (CX Valves) (CX Valves) (4MTLS) (XM 678 / 679) (EX Valves) - Synchronization of MT, LT and Parallel Compressors - Oil Management - Condenser

More information

Water Heating Technologies To Meet Energy & Environmental Challenges

Water Heating Technologies To Meet Energy & Environmental Challenges Water Heating Technologies To Meet Energy & Environmental Challenges Giovanni Zullo Vice President - Marketing & Planning Emerson Climate Technologies, Asia Pacific Our Vision: Emerson Climate Technologies,

More information

Smart Energy Systems Impact on Supermarkets

Smart Energy Systems Impact on Supermarkets Technical paper Smart Energy Systems Impact on Supermarkets By Torben Funder-Kristensen, Head of Public & Industry Affairs Danfoss Cooling, February 218 The energy agenda globally shifts towards reduced

More information

Rooftops High performance, proven reliability and easy installation

Rooftops High performance, proven reliability and easy installation Rooftops High performance, proven reliability and easy installation 1 Airfinity Rooftops Comfort and economy When it comes to installing and maintaining an HVAC system, every cent counts. From your initial

More information

Atlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-37 kw/10-50 hp)

Atlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-37 kw/10-50 hp) Atlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-37 kw/10-50 hp)! " $ $ % $ $ & ' ' & & ( ' ' & & Extreme savings No idling time Silent operation Small footprint The new revolutionary

More information

Space Engineering Services

Space Engineering Services Status The Worlds largest producer of CO 2 boostersystems (only CO 2 as refrigerant) Reference list: 1000 systems operating in 15 countries with more than 30 different retailers Production of 8-10 systems

More information

To efficiency and beyond

To efficiency and beyond AIRAH ( ACT ) presentation To efficiency and beyond Key drivers impacting today s HVAC choices Greenstar rating NABERS rating Mandatory disclosure Life Cycle Cost of Buildings Energy represents a significant

More information

BLDC waterloop systems in commercial refrigeration: the new frontier for natural refrigerants. Diego Malimpensa 17 th March 2015

BLDC waterloop systems in commercial refrigeration: the new frontier for natural refrigerants. Diego Malimpensa 17 th March 2015 BLDC waterloop systems in commercial refrigeration: the new frontier for natural refrigerants Diego Malimpensa 17 th March 2015 Energy efficiency in CO 2 systems Subcooler Parallel compression Evaporative

More information

Experimental evaluation of a CO2 transcritical refrigeration plant with dedicated mechanical subcooling

Experimental evaluation of a CO2 transcritical refrigeration plant with dedicated mechanical subcooling Experimental evaluation of a CO2 transcritical refrigeration plant with dedicated mechanical subcooling Rodrigo Llopis 1,*, Laura Nebot-Andrés 1, Ramón Cabello 1, Daniel Sánchez 1, Jesús Catalán-Gil 1

More information

Renewable Energy. to heat your home. thermia.com

Renewable Energy. to heat your home. thermia.com Renewable Energy Use air to heat your home all year round thermia.com Low-carbon heating is the key to sustainable development With the twin goals of reducing costs and maximizing sustainability, pressures

More information

ANNEXES. to the REPORT FROM THE COMMISSION

ANNEXES. to the REPORT FROM THE COMMISSION EUROPEAN COMMISSION Brussels, 4.8.2017 C(2017) 5230 final ANNEXES 1 to 2 ANNEXES to the REPORT FROM THE COMMISSION assessing the 2022 to avoid highly global warming Hydrofluorocarbons in some commercial

More information

Air Cooled Packaged Air Conditioning

Air Cooled Packaged Air Conditioning Cooling Capacity 11.6kW - 193.0kW Heating Capacity 10.8kW - 213.0kW eco series Packaged Air Conditioning Giving you complete control More than just another air conditioning company. temperzone is dedicated

More information

Optimizing Central Chilled Water Systems

Optimizing Central Chilled Water Systems Optimizing Central Chilled Water Systems OPTIMIZING CENTRAL CHILLED WATER SYSTEMS kent.peterson@p2seng.com 1 O P T I M I Z I N G C E N T R A L C H I L L E D W A T E R S Y S T E M S Kent W. Peterson, PE,

More information

Module 05 Lecture 35 : Low temperature process design Key words: Refrigeration system

Module 05 Lecture 35 : Low temperature process design Key words: Refrigeration system Refrigeration System Module 05 Lecture 35 : Low temperature process design Key words: Refrigeration system A refrigerator is simply a heat pump where heat is rejected to atmosphere( the sink). Fig.41.3(lecture

More information

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany Universal cooler in individual design BASELINE BL 006 BL 1440 Customized refrigeration technology Made in Germany 2 Lahntechnik your system partner for customized refrigeration technology For more than

More information

Experimental Study of a CO2 Thermal Battery for Simultaneous Cooling and Heating Applications

Experimental Study of a CO2 Thermal Battery for Simultaneous Cooling and Heating Applications Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Study of a CO2 Thermal Battery for Simultaneous Cooling and

More information

Retailers Ensure Sustainable Technology Uptake KIWI case Norway and transcritical technology fitting Asia

Retailers Ensure Sustainable Technology Uptake KIWI case Norway and transcritical technology fitting Asia Retailers Ensure Sustainable Technology Uptake KIWI case Norway and transcritical technology fitting Asia Anders Juul, Segment Strategy Manager Transcritical CO2 Goes global with support of retailers and

More information

Air Cooled Condensing Units - Technical Catalog. Featuring Copeland TM Compressors 404A and 507 Refrigerants

Air Cooled Condensing Units - Technical Catalog. Featuring Copeland TM Compressors 404A and 507 Refrigerants N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Copeland TM s 0A and 507 Refrigerants 9 Hunt St - Pryor, OK 736-98.85.7 - Fax 800.6.539 - www.century-refrigeration.com Standard Features

More information

Evaluation of R-449A as a Replacement for R-22 in Low and Medium Temperature Refrigeration

Evaluation of R-449A as a Replacement for R-22 in Low and Medium Temperature Refrigeration Evaluation of R-449A as a Replacement for R-22 in Low and Medium Temperature Refrigeration Andrew Pansulla, The Chemours Company Charles Allgood, The Chemours Company July 11-14, 2016 Agenda Regulations

More information

THE GREAT CHILLED WATER DEBATE. Michael Dagher

THE GREAT CHILLED WATER DEBATE. Michael Dagher THE GREAT CHILLED WATER DEBATE ichael Dagher Central Chiller Plant Direct-Primary, Variable Flow? Variable Primary / Variable Secondary (Decoupled)? Parallel Vs Series Counterflow? Pressure Control? What

More information

Zeta Rev HP XT. High efficiency air source reversible heat pumps heating kw. blueboxcooling.com. KINDERGARTEN Sofia - Bulgaria

Zeta Rev HP XT. High efficiency air source reversible heat pumps heating kw. blueboxcooling.com. KINDERGARTEN Sofia - Bulgaria Zeta Rev HP XT KINDERGARTEN Sofia - Bulgaria High efficiency air source reversible heat pumps heating 40 200 kw blueboxcooling.com General High efficiency air source reversible heat pumps. Options LN:

More information

Chilled Water Loop Optimization. Kazimir Gasljevic Richard Dewey Sandro Sanchez

Chilled Water Loop Optimization. Kazimir Gasljevic Richard Dewey Sandro Sanchez Chilled Water Loop Optimization Kazimir Gasljevic Richard Dewey Sandro Sanchez WHAT WE STARTED WITH: LOOP OUTLINE: WHAT WE STARTED WITH: LOOP OUTLINE: - Justification for the loop WHAT WE STARTED WITH:

More information

Enhancement of CO2 Refrigeration Cycle Using an Ejector: 1D Analysis

Enhancement of CO2 Refrigeration Cycle Using an Ejector: 1D Analysis Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Enhancement of CO2 Refrigeration Cycle Using an Ejector: 1D Analysis Elias

More information

State of the Art of Air-source Heat Pump for Cold Regions

State of the Art of Air-source Heat Pump for Cold Regions State of the Art of Air-source Heat Pump for Cold Regions Changqing Tian Nan Liang Ph D, Associate Prof. Ph D candidate Technical Institute of Physics and Chemistry, Chinese Academy of Sciences Beijing,

More information

Refrigeration in supermarkets Historic insight. November 2017

Refrigeration in supermarkets Historic insight. November 2017 Refrigeration in supermarkets Historic insight November 2017 Content Advansor s history in brief Natural refrigerants- the alternatives Historical system designs and why CO 2 had to win in the end! Developments

More information

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

Building Commissioning, Energy Efficiency & Building Automation Systems

Building Commissioning, Energy Efficiency & Building Automation Systems Independent Building Automation & Energy Management Building Commissioning, Energy Efficiency & Building Automation Systems June 1 st 2017 Overview Focus Energy Solutions Introduction Building Commissioning,

More information

Performance of Ductless Heat Pumps in the Northeast

Performance of Ductless Heat Pumps in the Northeast Performance of Ductless Heat Pumps in the Northeast Bruce Harley, CSG BE2014 / High Performance Mechanicals March 6, 2014 Amended 6/3/2014 Titles/details in RED indicate significant changes NESEA is a

More information

Nilan VPL Active heat recovery and cooling (air/air)

Nilan VPL Active heat recovery and cooling (air/air) M a r k e t l e a d i n g c o m m e r c i a l a n d d o m e s t i c v e n t i l at i o n w i t h h e at r e c o v e r y Nilan 31-125 Active heat recovery and cooling (air/air) Nilan 31-125 Commercial ventilation

More information

Heat pumps. Oilon ChillHeat. Optimized cooling and heating performance

Heat pumps. Oilon ChillHeat. Optimized cooling and heating performance Heat pumps Oilon ChillHeat Optimized cooling and heating performance Affordable, environmentally friendly energy with heat pumps Low-temperature waste heat contains valuable energy Communities, industry,

More information

Thermostatic expansion valves for R290 Product type TUB / TUBE and TCBE

Thermostatic expansion valves for R290 Product type TUB / TUBE and TCBE Data sheet Thermostatic expansion valves for R290 Product type and TUB/ and valves are made of stainless steel and are therefore very suitable for refrigeration systems in the food industry. Applications:

More information

Heat pumps. Oilon ChillHeat. Optimized cooling and heating performance

Heat pumps. Oilon ChillHeat. Optimized cooling and heating performance Heat pumps Oilon ChillHeat Optimized cooling and heating performance Affordable, environmentally friendly energy with heat pumps Low-temperature waste heat contains valuable energy Communities, industry,

More information

CO 2 Heat Pump System for Combined Heating and Cooling of Non-Residential Buildings

CO 2 Heat Pump System for Combined Heating and Cooling of Non-Residential Buildings The 22 nd IIR International Congress or Refrigeration Beijing, China CO 2 Heat Pump System for Combined Heating and Cooling of Non-Residential Buildings Jørn Stene (a,b), Arne Jakobsen (a), Trond Andresen

More information

Presentation Topic. Woolworths investment in the Australian industry to deliver sustainable HFC-free refrigeration innovation

Presentation Topic. Woolworths investment in the Australian industry to deliver sustainable HFC-free refrigeration innovation Presentation Topic Woolworths investment in the Australian industry to deliver sustainable HFC-free refrigeration innovation Technology uncertainty 10 years of uncertainty surrounding synthetic greenhouse

More information

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

Chapter Six{ TC Chapter Six \l 1 } System Simulation Chapter Six{ TC "Chapter Six" \l 1 } System Simulation In the previous chapters models of the components of the cooling cycle and of the power plant were introduced. The TRNSYS model of the power plant

More information

CO 2 the natural refrigerant for MT and LT in discounters, supermarkets and hypermarkets. October 19, 2009 Bernd Heinbokel

CO 2 the natural refrigerant for MT and LT in discounters, supermarkets and hypermarkets. October 19, 2009 Bernd Heinbokel CO 2 the natural refrigerant for MT and LT in discounters, supermarkets and hypermarkets October 19, 2009 Bernd Heinbokel 1 AGENDA Comparison of refrigerants Overview on subcritical LT cascade systems

More information

SIMPACK - MODEL DEVELOPMENT PACKAGE FOR POWER PLANTS

SIMPACK - MODEL DEVELOPMENT PACKAGE FOR POWER PLANTS SIMPACK - MODEL DEVELOPMENT PACKAGE FOR POWER PLANTS 1.0 OVERVIEW SIMPACK is a totally integrated set of simulation software development modules for power plants. It is template based modeling tool and

More information

Efficient, safe and green Get it all with Danfoss Smart Store

Efficient, safe and green Get it all with Danfoss Smart Store Brochure Food Retail Smart Store Efficient, safe and green Get it all with Danfoss Smart Store Proven in 50,000 installations around the world Learn more at smartstore.danfoss.com smartstore.danfoss.com

More information

Introduction to Geothermal Comfort Systems in INDIA

Introduction to Geothermal Comfort Systems in INDIA Introduction to Geothermal Comfort Systems in INDIA History Ancient earth sheltered homes 1912 Swiss Patent 1945 - First GSHP operating in North America in Indianapolis 1949 Canada s first GSHP installation

More information

Robert Kebby February BUILDING BLOCKS OF THE FUTURE Commercial Refrigeration Applications

Robert Kebby February BUILDING BLOCKS OF THE FUTURE Commercial Refrigeration Applications Robert Kebby February 2016 BUILDING BLOCKS OF THE FUTURE Commercial Refrigeration Applications Honeywell A History of Innovation CFCs HCFCs HFCs HFOs Very high ODP & GWP High ODP and GWP ODP=0, but high

More information

Thermostatic expansion valves Type T2 / TE2

Thermostatic expansion valves Type T2 / TE2 Data sheet Thermostatic expansion valves Type T2 / TE2 Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat.

More information

A NOVEL DESIGN OF COMPACT BRAZED PLATE HEAT EXCHANGER FOR CO2 TRANSCRITICAL APPLICATIONS

A NOVEL DESIGN OF COMPACT BRAZED PLATE HEAT EXCHANGER FOR CO2 TRANSCRITICAL APPLICATIONS A NOVEL DESIGN OF COMPACT BRAZED PLATE HEAT EXCHANGER FOR CO2 TRANSCRITICAL APPLICATIONS Why CO 2? Non-toxic, non-flammable. Non-ozone-depleting Environmentally friendly with GWP=1 Suitable for both transcritical

More information

7 th NATIONAL CERTIFICATION EXAMINATION Nov FOR ENERGY MANAGERS & ENERGY AUDITORS

7 th NATIONAL CERTIFICATION EXAMINATION Nov FOR ENERGY MANAGERS & ENERGY AUDITORS Regn No: Name: (To be written by the candidates) 7 th NATIONAL CERTIFICATION EXAMINATION Nov. 2008 FOR ENERGY MANAGERS & ENERGY AUDITORS PAPER 3: Energy Efficiency in Electrical Utilities Date: 23.11.2008

More information

Ontwikkelingen van hoge temperaturen warmtepompen Kenneth Hoffmann

Ontwikkelingen van hoge temperaturen warmtepompen Kenneth Hoffmann Ontwikkelingen van hoge temperaturen warmtepompen Kenneth Hoffmann Ontwikkelingen van hoge temperatuur warmtepompen KENNETH HOFFMANN, NOVEMBER, 2017 Why are industrial heat pumps needed? 3 How do industrial

More information

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

Thermostatic expansion valves Type T2 / TE2

Thermostatic expansion valves Type T2 / TE2 Data sheet Thermostatic expansion valves Type Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat. Therefore

More information

Integration of trigeneration and CO2 refrigeration systems for energy conservation in the food industry AFM 251

Integration of trigeneration and CO2 refrigeration systems for energy conservation in the food industry AFM 251 Integration of trigeneration and CO2 refrigeration systems for energy conservation in the food industry AFM 251 Savvas Tassou and INyoman Suamir On behalf of AFM251 consortium BRUNEL UNIVERSITY Content

More information

Energy Saving Report. Frigi-Tech Oil Additive. Application. In HKU Central Plant. Chiller No. 3

Energy Saving Report. Frigi-Tech Oil Additive. Application. In HKU Central Plant. Chiller No. 3 Energy Saving Report Of Frigi-Tech Oil Additive Application In HKU Central Plant Chiller No. 3 Prepared By: Evaluated and Endorsed By: December 2003 Eric P L Leung Sales Manager Electrical and Mechanical

More information

Thermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Thermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

Integrated Air Conditioning System

Integrated Air Conditioning System Integrated Air Conditioning System a smart solution for every building Contents TVR System 03 TVR System Advantage 04 TVR System Applications 05 Features - Inverter System 07 Features - Higher Reliability

More information

OPERATING INSTRUCTIONs ISTRUZIONI D USO. MODE d EMPLOI

OPERATING INSTRUCTIONs ISTRUZIONI D USO. MODE d EMPLOI OPERATING INSTRUCTIONs ISTRUZIONI D USO MODE d EMPLOI EN IT FR Control panel for air to water Inverter heat pump Pannello di controllo per pompa di calore Inverter aria / acqua Panneau de contrôle pour

More information

1st October Robert Kebby Marketing Manager

1st October Robert Kebby Marketing Manager 1st October 2014 Robert Kebby Marketing Manager Why R-404A? Success of R404A over the last 15 to 20 years - Replaced ODP products such as R12 / R502 & more recently R22 - Marketed well as a one solution

More information

Comparison of Integrated CO₂ Refrigerating Systems with Traditional HFC, and CO₂/HFC Hybrid and Cascade Systems in Australian Supermarkets

Comparison of Integrated CO₂ Refrigerating Systems with Traditional HFC, and CO₂/HFC Hybrid and Cascade Systems in Australian Supermarkets Comparison of Integrated CO₂ Refrigerating Systems with Traditional HFC, and CO₂/HFC Hybrid and Cascade Systems in Australian Supermarkets Klaas Visser Principal KAV CONSULTING Pty. Ltd. Dip.Mar.Eng. (NL)

More information

Agenda. Understanding the three basic piping systems. Low DeltaT Syndrome causes, effects, and solutions Design & Control Considerations (VPF)

Agenda. Understanding the three basic piping systems. Low DeltaT Syndrome causes, effects, and solutions Design & Control Considerations (VPF) Roy Hubbard Agenda Understanding the three basic piping systems Design and Off-design operation Advantages and Disadvantages Low DeltaT Syndrome causes, effects, and solutions Design & Control Considerations

More information

innovative accumulator tanks

innovative accumulator tanks GALÚ Accumulator Tanks are designed to optimise energy production, storage and distribution of energy produced for domestic hot water and heating. Water has excellent heat retention capabilities, therefore

More information

Pressure Booster System. Hya-Eco VP. Type Series Booklet

Pressure Booster System. Hya-Eco VP. Type Series Booklet Pressure Booster System ya-eco VP Type Series Booklet Legal information/copyright Type Series Booklet ya-eco VP All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Eurammon Symposium Ammonia Absorption Refrigeration. Colibri b.v.

Eurammon Symposium Ammonia Absorption Refrigeration. Colibri b.v. Eurammon Symposium 2016 Ammonia Absorption Refrigeration Michael Rabenstein Jürgen Langreck Colibri b.v. Introduction Colibri b.v. colibri b.v. experts in ammonia absorption refrigeration Products and

More information

AE R1 November, 2003

AE R1 November, 2003 AE4-1327 R1 November, 2003 ECONOMIZED VAPOR INJECTION (EVI) COMPRESSORS Introduction The Refrigeration Economized Vapor Injection (EVI) Compressor was developed to provide improved capacity and performance.

More information

WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR

WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR Supplier Checklist WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR The following checklist provides guidance on which information to collect from within the winery and from the equipment

More information

Unitary Air Conditioner Field Performance

Unitary Air Conditioner Field Performance Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2004 Unitary Air Conditioner Field Performance Todd M. Rossi Field Diagnostic

More information

WELCOME! 欢迎 光临. Roadmap

WELCOME! 欢迎 光临. Roadmap Roadmap Eurovent and refrigerants (Upcoming) realities Solutions that think ahead GEA Group: Optimizing heat recovery from industrial processes with NH3 heat pumps WELCOME! 欢迎 光临 8 April 2015 Ozone2Climate

More information