Danfoss and Controls for CO2
|
|
- Janis Hawkins
- 6 years ago
- Views:
Transcription
1 Danfoss and Controls for CO2 CO 2 Department (slide master) Optional text Date 1
2 Controllers for various CO2 applications Some examples of Danfoss controllers suited for CO2: AK-PC781 High-end multipurpose pack controller, incl.heat Reclaim, High pressure ctrl, parallel compressor, etc. AK-PC783 High-end cascade controller, incl. Heat Reclaim, high pressure ctrl, etc. AK-PC772 High-end limited to 3+2 compressors, 2 suction group controller, limited HR, parallel compressor, etc. Intended for small to medium sized supermarkets AK-CC550A FR-inject algorithm specially suited for CO2, Date
3 AK-PC781 AK-PC 781 shown in CO2 trans-critical booster system (MT/LT/IT) Control of one suction group including unloaders and speed! Condenser pressure control or gas cooler fan control! Gas cooler control! Gas by-pass! IT Parallel compression Tap water reclaim! Heat reclaim! Oil management and control! Date
4 AK-PC772 All transcritical control functions are integrated in AK-PC772 Heat Reclaim with optimum high pressure control based on actual indoor temperatures Optimum compressor capacity control via FC 103 (or digital scroll) Second suction group capacity control Receiver pressure ctrl by CCM Optimum pressure in Gas Cooler by CCMT or ICMTS Optimum media temperature out of Gas Cooler via FC 103 or EC-Fan Date
5 AK-PC783 CO 2 for both MT and LT with HFC on top Date
6 Improved surveillance using Service Tool - AK-PC781 Click on an icon and you will get see next slide! Date
7 Status and overview - Two Suction groups MT LT Date
8 Ease of use improved - Smart Settings Smart Settings allow fast setup of complex high pressure settings. Select just one Smart value for the High Pressure side, approx. 15 bar below Safety Valves, and the rest of parameters are calculated. Select just one Smart value below the receiver design pressure, to do the second calculation. Unused functions are hidden. E.g. if you deselect Receiver. Values can be changed after calculation, if preferred. Date
9 Floating fan control with Sc3 and Sgc temperature sensors Ref (for Sgc) temp. = Sc3 + tm + (dim-tm x cap/100) Sgc reference is mostly 2K above ambient temperature as dim and tm is set to equal values Sgc_Ref: ( Sc3 + 2K ) PI Fan capacity Sgc Date
10 Condenser improvements Improved floating condenser set point function compared to former AK-PC 780 Rule of thumb indicates 3 % energy savings on every 1 K on the condenser. condensing temp above Amb Condensing temp Compr Cap Energy savings compared to PC780 [%] Most compressor run time hours are in the 15% - 50% range PC780 PC Compr cap % Energy Savings % (Improved K) Date
11 Sub-critical vs. trans-critical CO 2 P [bar] 10 2 Subcritical Transcritical ,2 0,4 0,6 0, h [kj/kg] A trans-critical booster system can run both sub- and trans-critical. At lower temperatures than 31ºC the system runs sub-critical with a very good COP. At temperatures higher than the critical temperature (31ºC) CO 2 cannot condense therefore the system must run trans-critical with poorer COP as consequence In warmer climates a cascade system is often preferred because it has an advantage here. Cascade system has an extra cooling circuit, which can be used to cool the CO 2 circuit in order to keep the pressure down in this way avoiding trans-critical operation. Date
12 Integrated High Pressure controller Features: Maintain optimal COP in trans-critical areas Maintain optimal sub cooling in subcritical areas Safe transition between trans-critical and subcritical operation Optimum COP gas cooler control using the ICMTS or CCMT valve, Vhp Control of receiver pressure using the CCM (or ETS) valve, Vrec Heat reclaim with by pass of Gas Cooler, V3gc Use of radiometric pressure transmitters Supports 60, 100 and 160 bar pressure transmitters AKS 2050 Improved EKC 326a functionality Date
13 Benefits of integrated High Pressure controller High pressure systems can maintain either maximum COP or maximum system capacity for any given ambient condition Intermediate pressure is controlled independently and maintained on the required level All valve positions, measured temperatures and pressures are visible on the controller (one device) If required by Heat Recovery demand, the high pressure can be changed. Changeover is only allowed if several conditions are fulfilled, which makes a safe system (flow, temperatures, pressures, timers). A safe High Pressure operation has priority over other functions. Trans-critical optimum is a curve made by several tests and measurements Gas cooler pressure [bar] Date Refrigerating capacity [kw] and COP [-] New See Next COP QE OPERATING CONDITION t E = -10 C, t SH = 10 K t GC,OUT = 35 C
14 Optimal high pressure on trans-critical CO 2 COP = 1.90 COP = 2.31 COP = 2.28 h EVAP h COMP Date
15 Trans-critical vs. sub-critical CO 2 Date
16 Trans-critical vs. sub-critical CO C on gas leaving gas cooler Date
17 High Pressure system The Smart Settings make it easy to setup several HP settings by entering a single number. See Bold numbers and fig. Design criteria define levels. Safety valve and cut out switch ICMTS valve has 140 bar working pressure (0-10V control) CCMT valve has 140 bar working pressure (Stepper control) 120 bar Design pressure and setting of safety valve 115 bar High pressure switch cut-out (compressors) 103,5 bar Pc max limit (safety on Pack/Rack) 3 bar 100,5 bar Pc max start to make capacity reduction 100 bar Pgc Max, High pressure valve 100 % open 3 bar Pgc max. limit P-band 97 bar Pgc max. limit P-band where valve start to be forced open * Was in T in EKC 326, now in P Date
18 Maximum and minimum receiver pressure safety Date
19 Hot gas dump MT Pack Configuration Use hot gas dump Select whether hot gas should be supplied if the receiver pressure falls too low Prec hot gas dump Receiver pressure at which hot gas is turned on Prec gas dump diff. Difference at which hot gas is turned off again Date
20 Heat reclaim with CO 2 CO 2 has some excellent properties which can be utilized in heat reclaim High temperatures of the gas on the compressor outlet High enthalpy on the gas on the compressor outlet High density Good heat conductivity Heat reclaim can really be utilized above the critical temperature because gas rejects heat at higher temperatures with steady reduction in temperature through the heat exchanger. Above the critical temperature pressure and temperature can be controlled individually, which is an advantage in connection with heat reclaim. Date
21 Heat reclaim with CO 2 Demand for Heat Reclaim becomes more and more relevant due to rising energy costs. CO 2 applications are getting well known in Food Retail or Industrial systems and they run both subcritical and trans-critical. High discharge temperatures for CO 2 compression cycle is normal, often > 70 ºC This provide hot tap water (typically around 60 ºC) And low temperature heating for floor heating, radiators, air unit heater, etc. The Heat ratio is often x10 between hot tap water and heating A superior control strategy is necessary! 5 ºC 80 Bar 40 Bar T ºC MT -10 ºC 35 ºC Hot Tap Water x1 kwh Heating x10 kwh/day Energy Ratio, kwh 70 ºC 90 ºC Date
22 Achieving higher discharge temperatures The gas cooler rejects heat from the evaporator and compressor work In practice temperatures between ºC even with minimum compressor load can be achieved Heat reclaim between 25 and 65 ºC gives only a limited amount of heat If Pgc is raised when demand is present temperatures will increase to ºC Heat reclaim down to 25 ºC can now reject a large amount of heat The gas cooler will then only reject a small part of the heat Only little extra compressor work is needed! Log P 80 Bar 40 Bar -10 ºC 5 ºC 40 ºC 25 ºC water return Gas Cooler Heat to Gas Cooler MT -10 ºC Heat Reclaim Heat to Evaporator Heat Reclaim Work to Compressor Simplified CO2 refrigeration cycle 65 ºC 95 ºC h Date
23 Two stage Heat Reclaim integrated Features Control of hot Tap Water temperature Control of additional Heat reclaim source e.g. floor heating By pass valve for TW, HR and Gas Cooler Additional input (0-10V) from up to 5 heat consumers VSD (AKD, 0-10V) control of fans and water pumps to control water temperature Independent control of each subsystem, including safety conditions Date
24 Heat Reclaim There are 4 different heat reclaim control solutions in the system: Hot tap water Heat Reclaim, no HP offset (Pgc) Heat Reclaim, fixed HP offset Heat Reclaim, variable HP offset and Gas Cooler by-pass Log P 80 Bar 5 ºC 40 ºC water return TW 25 ºC water return HR Gas Cooler Heat reclaim Hot Tap Water Offset 40 Bar Pgc Heat Tap water 95 ºC This makes it possible to reclaim almost all heat and provide sufficient heat to most supermarkets in order to cover ALL the heat demand! -10 ºC MT -10 ºC h Date
25 Tap Water and Max Heat Reclaim mode Max Heat reclaim mode will control Pump speed Variable reference offset (Pgc) AND reduce fan speed AND finally gas cooler by-pass Up to 5 different heat consumers can give their reflected heat demand by a 0-10V signal, and the highest will determine the load on the system. The Ultimate heat reclaim is when Gas Cooler is by-passed. This will result in the red line. Which will increase running compressor capacity thus generating more heat. COP is decreased close to 1. Log P Gas Cooler by-pass = increasing compressor running capacity 80 Bar Offset 40 Bar -10 ºC 5 ºC 20 ºC water return HR Gas Cooler 40 ºC Heat reclaim Hot Tap Water Pgc MT -10 ºC Heat consumers 0-10V signal: 0-2 V: Variable pump speed 1-6 V: Variable offset (Pgc) 5-8 V: Reduce fan speed 7-10 V: By-pass gas cooler. Heat reclaim Hot Tap Water Heat Tap water 95 ºC h Date
26 Values Same energy efficiency (COP) as traditional HFC refrigeration systems CO2 does not effect the ozone layer CO2 has up to times lesser direct emission impact on global warming compared with traditional HFC refrigerants Produce high temperature tap water. (over 55 ºC/130 ºF) Produce heat in the store instead of rejecting the heat to the ambient Just one integrated electronic controller doing: Compressor and condenser capacity control High pressure control as well as heat recovery (CO2) Oil management and multi speed control (Compressor, fan, pump) Proven reliability of ADAP-KOOL controllers This controller is essential to make trans-critical systems work All former HFC functions are still available (as in AK-PC 740/780) Date
27 CO2 and Heat reclaim in Supermarkets White paper can be found in DILA 1. Save energy in your Supermarket with a CO2 Refrigeration system 2. Highly efficient heat reclaim with CO2 Two stage Heat Reclaim 1. Hot Tap Water, with 3-way valve 2. Heat Reclaim, with 3-way valve Save 10% on CO2 How to make Heat Reclaim Date
28 AK-CC 550A Case controller New functions in AK-CC 550A compared with AK-CC 550 S1 has been deleted Injection is controlled using Pe (Po) & S2 New Injection algorithm (FR-Inject) * Adaptive Defrost with skip function * The opening degree is reduced more rapidly, if liquid is detected after the Evaporator or low SH. Security function ensures that the valve closes if the SH get below the set limit. Department (slide master) Optional text Date 28
29 SS U RE NS MITT ER AKS 33 0G Pe : bar ps ig / MW P 5 80 p sig V d.c m A + SU PP LY VO LTA GE - C O MMO N AK-CC 550A Case controller FR inject function The superheat is reduced until the signal becomes unstable. Search speed is 0,25 K per 8 minutes. Then superheat is increased a bit until stability is found followed by a new reduction, and so on! AKV 10 S2 P e SH = S2 - T e Superheat in K TIME Superheat set point Actual superheat Department (slide master) Optional text Date 29
30 AK-CC 550A Case controller FR inject function Advantages: Integrated solenoid valve Adaptive adjustment Optimum utilisation at all load conditions Insensitive to operation conditions Compensate low Pc with higher opening degree Typical 5 10 % energy savings (TEV s are not available for CO 2 ) Superheat set point Actual superheat Department (slide master) Optional text Date 30
31 AK-CC 550A Case controller Evaporator design CO 2 has different properties than other refrigerants due to the high pressure Density of the gas is approximately 3 to 10 times higher than conventional refrigerants and therefore getting gas velocities high enough is a problem in evaporators Pressure drop has only very little influence on the evaporation temperature Long pipes in one sling gives long reaction time for the control Use small diameter and a pressure drop of ½-1 bar. Avoid long pipes To low velocity and surface is dry High velocity and wet surface Date
32 Refrigeration performance, ADAP-KOOL Value ADAP-KOOL monitoring modules AK-LM 350 AK-LM 340 AK-LM 330 Application Temperature monitoring Multi purpose ctrl COP monitoring Date
33 Refrigeration performance, ADAP-KOOL AK-LM 3xx function overview AK-LM330 AK-LM340 AK-LM350 Thermostats w. defrost interlock Pressostats functions Voltage input functions Digital alarm input functions Utility / Pulse meter input functions Alarm relay outputs PI controls advanced 10 Thermostat w. 2 sensor inputs 10 Temperature alarms 10 Difference thermostat 10 Differential pressostat 10 Pressure alarms 10 COP monitoring - CO2 boost, / cascade/one stage 1 Department (slide master) Optional text Date 33
34 Refrigeration performance, ADAP-KOOL Why COP and what is it? How can we measure if a refrigeration works good enough? Can we compare refrigeration plants, regarding energy consumption? COP = Obtained _ energy Used _ Power Are there any useful key numbers for refrigeration plants? Department (slide master) Optional text Date 34
35 Refrigeration performance, ADAP-KOOL What is an ideal COP? When calculating a COP for a refrigeration, it is possible to calculate an ideal COP, which can never be achieved. But, calculating the ratio between actual COP and ideal COP, tells how efficient the refrigeration plant is. Qo is the cooling removed at the MT level, and the ideal power consumption is calculated! When trimming/optimizing the refrigeration plant, one should try to lift the actual COP as much as possible! COP MT, Ideal = Q Power 0, MT MT, ideal Department (slide master) Optional text Date 35
36 Refrigeration performance, ADAP-KOOL What is an ideal COP? When calculating a COP for a refrigeration, it is possible to calculate an ideal COP, which can never be achieved. But, calculating the ratio between actual COP and ideal COP, tells how efficient the refrigeration plant is. Qo is the cooling removed at the MT level, and the ideal power consumption is calculated! When trimming/optimizing the refrigeration plant, one should try to lift the actual COP as much as possible! COP MT, Ideal = Q Power 0, MT MT, ideal Department (slide master) Optional text Date 36
37 Refrigeration performance, KPIs KPIs Service tool picture from a live installation. As can be seen various averages is calculated - 1 minute - 1 hour - 24 hour - All data can be collected by ADAP- KOOL system. Please NOTE: Valid flag (OK) shows if calculation is valid. One should calculate how many % valid data is present. If Valid % data > 70%, plant is stable and performing If Valid % data < 50%, you need to investigate, and COP could also be low Date
38 Frontend Comparing Supermarkets When it is possible to provide data from the supermarkets, it is possible to evaluate: Planteffic iency = COP COP actual Ideal Power consumption Energy consumption Costs Heat reclaim Operating patterns Plant efficiency Cooling load pr. M display case Date
39 Frontend Comparing Supermarkets Whats the reason for the low plant performance? And just as important: What is the cost of low plant efficiency? The cost of TOO low performance for inst.2 is calculated to: App. 336 Euro pr week Note: Depends upon prices for electricity at varoius geographical sites, and size of supermarket. AND..valve lifetime is degrading fast AND...compressors is switching fast, thus wearing down faster. Date
40 Refrigeration performance, reports Important info from COP Below table is a report generated in Danfoss Demo tool, on 4 actual supermarkets. Different info is available: - Potential savings pr day - Percent valid calculations(very important because it indicates if there is loose sensors, bad settings in controllers, etc, below 70% it could be necessary to check the plant) - COP for individual sites(should be at a certain level) Shop City Plant efficiency Pot. Savings pr day kwh P-MT [kw] P-LT [kw] COP-MT COP-LT Pct Valid Shop1 City Shop2 City Shop3 City Shop 4 City Department (slide master) Optional text Date 40
41 End Date
High efficient heat reclaim with CO2
High efficient heat reclaim with CO2 Refrigeration systems with transcritical CO 2 has been taking market shares the last years. Since 2007 the market in Denmark has turned from conventional refrigeration
More informationDanfoss the pioneer in electronic expansion valve control
Technical paper Danfoss the pioneer in electronic expansion valve control When Danfoss introduced it s first microprocessor based ADAP-KOOL controller back in 1987 it was also the first controller with
More informationMulti Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)
Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low (LP) Danfoss Multi Ejector Solution TM, consists of a CTM 6 Low valve and an AK-PC 782A controller. This solution makes CO
More informationMulti Ejector Solution Transcritical CO 2 refrigeration systems in all climates
Multi Ejector Solution Transcritical CO 2 refrigeration systems in all climates Mark Sever, Technical Manager 1 Danfoss Cooling Multi Ejector Solution The CO 2 development First, second, and third generation
More informationMulti Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)
Data sheet Multi Ejector Solution TM for R744 (CO 2 ) - CTM 6 High (HP) Multi Ejector Solution TM, consists of a CTM 6 High valve and an AK-PC 782A controller. This solution makes CO 2 refrigeration systems
More informationCO2 solutions February 2018
CO2 solutions 27-28 February 2018 Summary Overview of regulations Overview of Rivacold solution CO2 carbon dioxide CO2 Rivacold solution Case History 2 1. Overview of regulations Overview of regulations
More informationType CTM 6 High Pressure (HP) and Low Pressure (LP)
Application guide How to design a transcritical CO 2 system with Multi Ejector Solution. Type CTM 6 High Pressure (HP) and Low Pressure (LP) www.danfoss.com Table of content What is the Multi Ejector Solution?
More informationYEARLY SIMULATION OF CO 2 REFRIGERATION SYSTEMS FOR SUPERMARKET APPLICATIONS
YEARLY SIMULATION OF CO 2 REFRIGERATION SYSTEMS FOR SUPERMARKET APPLICATIONS FRASCOLD SPA FRASCOLD SpA! Italy (1936)! Frascold USA! (2014)! Frascold Shanghai! (2014)! Frascold India! (2012)! Sales office!
More informationOne. Discover the opportunities of CO 2. refrigeration. refrigerants.danfoss.com/co2. Brochure Natural refrigeration. Safe Efficient - Green
Brochure Natural refrigeration Discover the opportunities of refrigeration Safe Efficient - Green One natural and efficient system for all your cooling and heating needs refrigerants.danfoss.com/co2 Why
More informationTHE INSTITUTE OF REFRIGERATION
Advance Proof. Private to members Copyright 2009 The Institute of Refrigeration No publication or reprinting without authority THE INSTITUTE OF REFRIGERATION Living without HFCs The Danish Experience by
More informationRefrigeration System with Booster Hot Gas Bypass in Tropical Climate
Journal of Physics: Conference Series PAPER OPEN ACCESS Simulation of Transcritical CO 2 Refrigeration System with Booster Hot Gas Bypass in Tropical Climate To cite this article: I D M C Santosa et al
More informationCOP Improvement Of A CO2 Refrigeration System With An Expander-Compressor-Unit (ECU) In Subcritical And Transcritical Operation
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 COP Improvement Of A CO2 Refrigeration System With An Expander-Compressor-Unit
More information24/7 monitoring and supervision of your system
Overview Brochure ADAP-KOOL System Managers Achieve your energy goals with the best control and system management for Food Retail 24/7 monitoring and supervision of your system food-retail.danfoss.com
More informationTrends in Refrigeration System Architecture and CO 2. Andre Patenaude Emerson Climate Technologies
Trends in Refrigeration System Architecture and CO 2 Andre Patenaude Emerson Climate Technologies What s Hot in Supermarket Refrigeration? MT Cases With Doors LED Lighting Low Condensing ECM Fan Motors
More informationCO2 refrigeration and Its applications. Benoit Rodier, P.Eng.
CO2 refrigeration and Its applications Benoit Rodier, P.Eng. History of CO 2 Transcritical Cycle CO 2 Peak period of CO 2 First usage of CO 2 as a refrigerant (Alexander Twining,British patent) J&E Hall
More informationCO 2 the natural refrigerant for MT and LT in discounters, super- and hypermarkets PE4, Bernd Heinbokel
CO 2 the natural refrigerant for MT and LT in discounters, super- and hypermarkets 18.08.09 PE4, Bernd Heinbokel AGENDA 1 Legislation in Europe, trends Comparison of refrigerants Overview on subcritical
More informationVariable Speed Solutions. Outstanding performance for residential applications
Variable Speed Solutions Outstanding performance for residential applications Heat pumps - an efficient technology using renewable energy Environmental impact, reduction of carbon footprint and energy
More information> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION Available range Unit type IH Heat pump IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS
More informationAn Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 An Integrated Solution for Commercial AC Chillers Using Variable Speed
More informationCold Plate economy and ecology in supermarkets
Cold Plate economy and ecology in supermarkets ColdPlate Cold Plate efficiency Environmental and commercial support Many synthetic refrigerants have unwanted global warming and ozone depletion effects,
More informationVariable Speed Solutions Outstanding Performance For Heat Pump Applications
Variable Speed Solutions Outstanding Performance For Heat Pump Applications Your Choice For An Efficient Heating Solution Emerson Climate Technologies offers a wide selection of products from single components
More informationCOP-OPTIMISED PRESSURE CONTROL FOR A CENTRALISED CO 2 COOLING SYSTEM IN AIRCRAFT APPLICATIONS
COP-OPTIMISED PRESSURE CONTROL FOR A CENTRALISED CO 2 COOLING SYSTEM IN AIRCRAFT APPLICATIONS S. ADEYEFA, O. SCHADE, U. CARL Hamburg University of Technology, Department of Aircraft Systems Engineering
More informationPostprint. This is the accepted version of a paper presented at 13th IIR Gustav Lorentzen Conference.
http://www.diva-portal.org Postprint This is the accepted version of a paper presented at 13th IIR Gustav Lorentzen Conference. Citation for the original published paper: Raka Adrianto, L., Grandjean,
More informationAir Cooled Chiller (50Hz) Air Cooled Scroll. Air Cooled Screw ACC 05/15
ir Cooled Chiller (50Hz) ir Cooled Scroll ir Cooled Screw CC 05/15 ir Cooled Scroll Chiller ir Cooled Scroll Chiller - Product Lineup No Model Heat Compressor Electrical exchanger quantity(pcs) Maximum
More informationCAREL & CO 2 Technology!
CAREL &! CO 2 Technology!!!!!!!!!!!!!!!!!!!!!!!!!!Global&Key&Account&Manager&& &&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&Retail!! Agenda CAREL CO 2 Experience Advanced CO 2
More informationAir Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants
N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Bitzer TM s 404A and 507 Refrigerants 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Standard
More informationIndustrial Heat Pumps
IEA Meeting Technological Institute, Aarhus, Denmark Industrial Heat Pumps If the you can read this Click on the icon to choose a picture or Reset the slide. To Reset: Right click on the slide thumbnail
More informationSet Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that.
Set Free Modular FSXN Engineering for tomorrow. And the tomorrow after that. 0 03 Introducing a new addition to Hitachi s Set Free range of VRF air conditioning units - enhancing efficiency and user experience
More informationEnhanced Refrigeration Solutions. CMPX Show Thursday March 19 th,2014
Enhanced Refrigeration Solutions Andre.Patenaude@emerson.com Director of Marketing, CO2 Business Development CMPX Show Thursday March 19 th,2014 Enhanced Refrigeration Solutions Enhanced Refrigeration
More informationApplication Of Oil Flooded Compression With Regeneration To A Packaged Heat Pump System
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 14 Application Of Oil Flooded Compression With Regeneration To A Packaged Heat
More informationa comparative study of secondary glycol and direct expansion refrigeration systems
a comparative study of secondary glycol and direct expansion refrigeration systems Second Nature Medium-Temperature secondary systems have been widely applied in commercial refrigeration since their introduction
More informationCO 2 Transcritical Cycle for Ground Source Heat Pump
CO 2 Transcritical Cycle for Ground Source Heat Pump.Ma Yitai, professor, Thermal energy research institute of Tianjin University, Tianjin, China Wang Jinggang, PhD student, Thermal energy research institute
More informationNatural refrigerants, a complete solution Latest technological advancements for warm climates
Natural refrigerants, a complete solution Latest technological advancements for warm climates Prof. Dr. Armin Hafner No 7491 Trondheim Norway E mail: armin.hafner@ntnu.no Introduction The revival of natural
More informationIntegration of the hidden refrigeration capacity as a heat pump in smart energy systems
Integration of the hidden refrigeration capacity as a heat pump in smart energy systems Torben Funder-Kristensen This presentation outlines the concepts behind the Danish EUDP-project (64016-0106) Super
More informationDesign and development of a residential gas-fired heat pump
Design and development of a residential gas-fired heat pump Edward A Vineyard a*, Ahmad Abu-Heiba a, Isaac Mahderekal b a Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN, 37831, USA
More informationTrends in Refrigeration System Architecture and CO 2. Derek Gosselin Hillphoenix
Trends in Refrigeration System Architecture and CO 2 Derek Gosselin Hillphoenix Impact of Systems Architecture Refrigerants Impact on the Environment Different Types of System Architectures Energy s Impact
More informationPerformance Comparison of Air-source Heat Pumps Using Economizer Vapor Injection and Internal Heat Exchanger in Cold Regions
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Performance Comparison of Air-source Heat Pumps Using Economizer Vapor
More informationCompressed Air. How to Justify Projects and Achieve Significant Savings in Multiple Compressor Environments
Compressed Air How to Justify Projects and Achieve Significant Savings in Multiple Compressor Environments Tom Sherman, CEM, CDSM PCX Energy Services, LLC Justifying Projects KEY: Reduce/Eliminate Perceived
More informationHeat Pump Hot Water Supply Systems
2007年度版 Heat Pump Hot Water Supply Systems (1) Aims A great amount of energy is consumed for supplying hot water in the residential, commercial and industrial sectors. emission from residential hot water
More informationCopeland Transcritical 4MTLS CO 2 Compressors. June 2016
Copeland Transcritical 4MTLS CO 2 Compressors June 2016 (i-pro CO2 ) (CX Valves) (CX Valves) (4MTLS) (XM 678 / 679) (EX Valves) - Synchronization of MT, LT and Parallel Compressors - Oil Management - Condenser
More informationWater Heating Technologies To Meet Energy & Environmental Challenges
Water Heating Technologies To Meet Energy & Environmental Challenges Giovanni Zullo Vice President - Marketing & Planning Emerson Climate Technologies, Asia Pacific Our Vision: Emerson Climate Technologies,
More informationSmart Energy Systems Impact on Supermarkets
Technical paper Smart Energy Systems Impact on Supermarkets By Torben Funder-Kristensen, Head of Public & Industry Affairs Danfoss Cooling, February 218 The energy agenda globally shifts towards reduced
More informationRooftops High performance, proven reliability and easy installation
Rooftops High performance, proven reliability and easy installation 1 Airfinity Rooftops Comfort and economy When it comes to installing and maintaining an HVAC system, every cent counts. From your initial
More informationAtlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-37 kw/10-50 hp)
Atlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-37 kw/10-50 hp)! " $ $ % $ $ & ' ' & & ( ' ' & & Extreme savings No idling time Silent operation Small footprint The new revolutionary
More informationSpace Engineering Services
Status The Worlds largest producer of CO 2 boostersystems (only CO 2 as refrigerant) Reference list: 1000 systems operating in 15 countries with more than 30 different retailers Production of 8-10 systems
More informationTo efficiency and beyond
AIRAH ( ACT ) presentation To efficiency and beyond Key drivers impacting today s HVAC choices Greenstar rating NABERS rating Mandatory disclosure Life Cycle Cost of Buildings Energy represents a significant
More informationBLDC waterloop systems in commercial refrigeration: the new frontier for natural refrigerants. Diego Malimpensa 17 th March 2015
BLDC waterloop systems in commercial refrigeration: the new frontier for natural refrigerants Diego Malimpensa 17 th March 2015 Energy efficiency in CO 2 systems Subcooler Parallel compression Evaporative
More informationExperimental evaluation of a CO2 transcritical refrigeration plant with dedicated mechanical subcooling
Experimental evaluation of a CO2 transcritical refrigeration plant with dedicated mechanical subcooling Rodrigo Llopis 1,*, Laura Nebot-Andrés 1, Ramón Cabello 1, Daniel Sánchez 1, Jesús Catalán-Gil 1
More informationRenewable Energy. to heat your home. thermia.com
Renewable Energy Use air to heat your home all year round thermia.com Low-carbon heating is the key to sustainable development With the twin goals of reducing costs and maximizing sustainability, pressures
More informationANNEXES. to the REPORT FROM THE COMMISSION
EUROPEAN COMMISSION Brussels, 4.8.2017 C(2017) 5230 final ANNEXES 1 to 2 ANNEXES to the REPORT FROM THE COMMISSION assessing the 2022 to avoid highly global warming Hydrofluorocarbons in some commercial
More informationAir Cooled Packaged Air Conditioning
Cooling Capacity 11.6kW - 193.0kW Heating Capacity 10.8kW - 213.0kW eco series Packaged Air Conditioning Giving you complete control More than just another air conditioning company. temperzone is dedicated
More informationOptimizing Central Chilled Water Systems
Optimizing Central Chilled Water Systems OPTIMIZING CENTRAL CHILLED WATER SYSTEMS kent.peterson@p2seng.com 1 O P T I M I Z I N G C E N T R A L C H I L L E D W A T E R S Y S T E M S Kent W. Peterson, PE,
More informationModule 05 Lecture 35 : Low temperature process design Key words: Refrigeration system
Refrigeration System Module 05 Lecture 35 : Low temperature process design Key words: Refrigeration system A refrigerator is simply a heat pump where heat is rejected to atmosphere( the sink). Fig.41.3(lecture
More informationUniversal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany
Universal cooler in individual design BASELINE BL 006 BL 1440 Customized refrigeration technology Made in Germany 2 Lahntechnik your system partner for customized refrigeration technology For more than
More informationExperimental Study of a CO2 Thermal Battery for Simultaneous Cooling and Heating Applications
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Study of a CO2 Thermal Battery for Simultaneous Cooling and
More informationRetailers Ensure Sustainable Technology Uptake KIWI case Norway and transcritical technology fitting Asia
Retailers Ensure Sustainable Technology Uptake KIWI case Norway and transcritical technology fitting Asia Anders Juul, Segment Strategy Manager Transcritical CO2 Goes global with support of retailers and
More informationAir Cooled Condensing Units - Technical Catalog. Featuring Copeland TM Compressors 404A and 507 Refrigerants
N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Copeland TM s 0A and 507 Refrigerants 9 Hunt St - Pryor, OK 736-98.85.7 - Fax 800.6.539 - www.century-refrigeration.com Standard Features
More informationEvaluation of R-449A as a Replacement for R-22 in Low and Medium Temperature Refrigeration
Evaluation of R-449A as a Replacement for R-22 in Low and Medium Temperature Refrigeration Andrew Pansulla, The Chemours Company Charles Allgood, The Chemours Company July 11-14, 2016 Agenda Regulations
More informationTHE GREAT CHILLED WATER DEBATE. Michael Dagher
THE GREAT CHILLED WATER DEBATE ichael Dagher Central Chiller Plant Direct-Primary, Variable Flow? Variable Primary / Variable Secondary (Decoupled)? Parallel Vs Series Counterflow? Pressure Control? What
More informationZeta Rev HP XT. High efficiency air source reversible heat pumps heating kw. blueboxcooling.com. KINDERGARTEN Sofia - Bulgaria
Zeta Rev HP XT KINDERGARTEN Sofia - Bulgaria High efficiency air source reversible heat pumps heating 40 200 kw blueboxcooling.com General High efficiency air source reversible heat pumps. Options LN:
More informationChilled Water Loop Optimization. Kazimir Gasljevic Richard Dewey Sandro Sanchez
Chilled Water Loop Optimization Kazimir Gasljevic Richard Dewey Sandro Sanchez WHAT WE STARTED WITH: LOOP OUTLINE: WHAT WE STARTED WITH: LOOP OUTLINE: - Justification for the loop WHAT WE STARTED WITH:
More informationEnhancement of CO2 Refrigeration Cycle Using an Ejector: 1D Analysis
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Enhancement of CO2 Refrigeration Cycle Using an Ejector: 1D Analysis Elias
More informationState of the Art of Air-source Heat Pump for Cold Regions
State of the Art of Air-source Heat Pump for Cold Regions Changqing Tian Nan Liang Ph D, Associate Prof. Ph D candidate Technical Institute of Physics and Chemistry, Chinese Academy of Sciences Beijing,
More informationRefrigeration in supermarkets Historic insight. November 2017
Refrigeration in supermarkets Historic insight November 2017 Content Advansor s history in brief Natural refrigerants- the alternatives Historical system designs and why CO 2 had to win in the end! Developments
More informationi-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationBuilding Commissioning, Energy Efficiency & Building Automation Systems
Independent Building Automation & Energy Management Building Commissioning, Energy Efficiency & Building Automation Systems June 1 st 2017 Overview Focus Energy Solutions Introduction Building Commissioning,
More informationPerformance of Ductless Heat Pumps in the Northeast
Performance of Ductless Heat Pumps in the Northeast Bruce Harley, CSG BE2014 / High Performance Mechanicals March 6, 2014 Amended 6/3/2014 Titles/details in RED indicate significant changes NESEA is a
More informationNilan VPL Active heat recovery and cooling (air/air)
M a r k e t l e a d i n g c o m m e r c i a l a n d d o m e s t i c v e n t i l at i o n w i t h h e at r e c o v e r y Nilan 31-125 Active heat recovery and cooling (air/air) Nilan 31-125 Commercial ventilation
More informationHeat pumps. Oilon ChillHeat. Optimized cooling and heating performance
Heat pumps Oilon ChillHeat Optimized cooling and heating performance Affordable, environmentally friendly energy with heat pumps Low-temperature waste heat contains valuable energy Communities, industry,
More informationThermostatic expansion valves for R290 Product type TUB / TUBE and TCBE
Data sheet Thermostatic expansion valves for R290 Product type and TUB/ and valves are made of stainless steel and are therefore very suitable for refrigeration systems in the food industry. Applications:
More informationHeat pumps. Oilon ChillHeat. Optimized cooling and heating performance
Heat pumps Oilon ChillHeat Optimized cooling and heating performance Affordable, environmentally friendly energy with heat pumps Low-temperature waste heat contains valuable energy Communities, industry,
More informationCO 2 Heat Pump System for Combined Heating and Cooling of Non-Residential Buildings
The 22 nd IIR International Congress or Refrigeration Beijing, China CO 2 Heat Pump System for Combined Heating and Cooling of Non-Residential Buildings Jørn Stene (a,b), Arne Jakobsen (a), Trond Andresen
More informationPresentation Topic. Woolworths investment in the Australian industry to deliver sustainable HFC-free refrigeration innovation
Presentation Topic Woolworths investment in the Australian industry to deliver sustainable HFC-free refrigeration innovation Technology uncertainty 10 years of uncertainty surrounding synthetic greenhouse
More informationChapter Six{ TC "Chapter Six" \l 1 } System Simulation
Chapter Six{ TC "Chapter Six" \l 1 } System Simulation In the previous chapters models of the components of the cooling cycle and of the power plant were introduced. The TRNSYS model of the power plant
More informationCO 2 the natural refrigerant for MT and LT in discounters, supermarkets and hypermarkets. October 19, 2009 Bernd Heinbokel
CO 2 the natural refrigerant for MT and LT in discounters, supermarkets and hypermarkets October 19, 2009 Bernd Heinbokel 1 AGENDA Comparison of refrigerants Overview on subcritical LT cascade systems
More informationSIMPACK - MODEL DEVELOPMENT PACKAGE FOR POWER PLANTS
SIMPACK - MODEL DEVELOPMENT PACKAGE FOR POWER PLANTS 1.0 OVERVIEW SIMPACK is a totally integrated set of simulation software development modules for power plants. It is template based modeling tool and
More informationEfficient, safe and green Get it all with Danfoss Smart Store
Brochure Food Retail Smart Store Efficient, safe and green Get it all with Danfoss Smart Store Proven in 50,000 installations around the world Learn more at smartstore.danfoss.com smartstore.danfoss.com
More informationIntroduction to Geothermal Comfort Systems in INDIA
Introduction to Geothermal Comfort Systems in INDIA History Ancient earth sheltered homes 1912 Swiss Patent 1945 - First GSHP operating in North America in Indianapolis 1949 Canada s first GSHP installation
More informationRobert Kebby February BUILDING BLOCKS OF THE FUTURE Commercial Refrigeration Applications
Robert Kebby February 2016 BUILDING BLOCKS OF THE FUTURE Commercial Refrigeration Applications Honeywell A History of Innovation CFCs HCFCs HFCs HFOs Very high ODP & GWP High ODP and GWP ODP=0, but high
More informationThermostatic expansion valves Type T2 / TE2
Data sheet Thermostatic expansion valves Type T2 / TE2 Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat.
More informationA NOVEL DESIGN OF COMPACT BRAZED PLATE HEAT EXCHANGER FOR CO2 TRANSCRITICAL APPLICATIONS
A NOVEL DESIGN OF COMPACT BRAZED PLATE HEAT EXCHANGER FOR CO2 TRANSCRITICAL APPLICATIONS Why CO 2? Non-toxic, non-flammable. Non-ozone-depleting Environmentally friendly with GWP=1 Suitable for both transcritical
More information7 th NATIONAL CERTIFICATION EXAMINATION Nov FOR ENERGY MANAGERS & ENERGY AUDITORS
Regn No: Name: (To be written by the candidates) 7 th NATIONAL CERTIFICATION EXAMINATION Nov. 2008 FOR ENERGY MANAGERS & ENERGY AUDITORS PAPER 3: Energy Efficiency in Electrical Utilities Date: 23.11.2008
More informationOntwikkelingen van hoge temperaturen warmtepompen Kenneth Hoffmann
Ontwikkelingen van hoge temperaturen warmtepompen Kenneth Hoffmann Ontwikkelingen van hoge temperatuur warmtepompen KENNETH HOFFMANN, NOVEMBER, 2017 Why are industrial heat pumps needed? 3 How do industrial
More informationi-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationThermostatic expansion valves Type T2 / TE2
Data sheet Thermostatic expansion valves Type Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat. Therefore
More informationIntegration of trigeneration and CO2 refrigeration systems for energy conservation in the food industry AFM 251
Integration of trigeneration and CO2 refrigeration systems for energy conservation in the food industry AFM 251 Savvas Tassou and INyoman Suamir On behalf of AFM251 consortium BRUNEL UNIVERSITY Content
More informationEnergy Saving Report. Frigi-Tech Oil Additive. Application. In HKU Central Plant. Chiller No. 3
Energy Saving Report Of Frigi-Tech Oil Additive Application In HKU Central Plant Chiller No. 3 Prepared By: Evaluated and Endorsed By: December 2003 Eric P L Leung Sales Manager Electrical and Mechanical
More informationThermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Thermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationIntegrated Air Conditioning System
Integrated Air Conditioning System a smart solution for every building Contents TVR System 03 TVR System Advantage 04 TVR System Applications 05 Features - Inverter System 07 Features - Higher Reliability
More informationOPERATING INSTRUCTIONs ISTRUZIONI D USO. MODE d EMPLOI
OPERATING INSTRUCTIONs ISTRUZIONI D USO MODE d EMPLOI EN IT FR Control panel for air to water Inverter heat pump Pannello di controllo per pompa di calore Inverter aria / acqua Panneau de contrôle pour
More information1st October Robert Kebby Marketing Manager
1st October 2014 Robert Kebby Marketing Manager Why R-404A? Success of R404A over the last 15 to 20 years - Replaced ODP products such as R12 / R502 & more recently R22 - Marketed well as a one solution
More informationComparison of Integrated CO₂ Refrigerating Systems with Traditional HFC, and CO₂/HFC Hybrid and Cascade Systems in Australian Supermarkets
Comparison of Integrated CO₂ Refrigerating Systems with Traditional HFC, and CO₂/HFC Hybrid and Cascade Systems in Australian Supermarkets Klaas Visser Principal KAV CONSULTING Pty. Ltd. Dip.Mar.Eng. (NL)
More informationAgenda. Understanding the three basic piping systems. Low DeltaT Syndrome causes, effects, and solutions Design & Control Considerations (VPF)
Roy Hubbard Agenda Understanding the three basic piping systems Design and Off-design operation Advantages and Disadvantages Low DeltaT Syndrome causes, effects, and solutions Design & Control Considerations
More informationinnovative accumulator tanks
GALÚ Accumulator Tanks are designed to optimise energy production, storage and distribution of energy produced for domestic hot water and heating. Water has excellent heat retention capabilities, therefore
More informationPressure Booster System. Hya-Eco VP. Type Series Booklet
Pressure Booster System ya-eco VP Type Series Booklet Legal information/copyright Type Series Booklet ya-eco VP All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationEurammon Symposium Ammonia Absorption Refrigeration. Colibri b.v.
Eurammon Symposium 2016 Ammonia Absorption Refrigeration Michael Rabenstein Jürgen Langreck Colibri b.v. Introduction Colibri b.v. colibri b.v. experts in ammonia absorption refrigeration Products and
More informationAE R1 November, 2003
AE4-1327 R1 November, 2003 ECONOMIZED VAPOR INJECTION (EVI) COMPRESSORS Introduction The Refrigeration Economized Vapor Injection (EVI) Compressor was developed to provide improved capacity and performance.
More informationWINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR
Supplier Checklist WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR The following checklist provides guidance on which information to collect from within the winery and from the equipment
More informationUnitary Air Conditioner Field Performance
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2004 Unitary Air Conditioner Field Performance Todd M. Rossi Field Diagnostic
More informationWELCOME! 欢迎 光临. Roadmap
Roadmap Eurovent and refrigerants (Upcoming) realities Solutions that think ahead GEA Group: Optimizing heat recovery from industrial processes with NH3 heat pumps WELCOME! 欢迎 光临 8 April 2015 Ozone2Climate
More information