EXAECO RANGE ENERGY RECUPERATION

Size: px
Start display at page:

Download "EXAECO RANGE ENERGY RECUPERATION"

Transcription

1 ENERGY RECUPERATION RANGE Very high efficiency, high performance, self-regulating double flow unit. Econological solution compliant with ErP29/125/EC. CALADAIR I 61 rue de Saint Véran I 71 MÂCON LOCHÉ I Tél. 33 () Fax 33 () I P27

2 ENERGY RECUPERATION DOUBLE FLOW UNIT DESCRIPTION APPLICATION Ventilation, energy recovery, thermal comfort and innovating and optimal treatment of indoor quality. Self-regulated, high efficiency and high performance unit for office and industrial installations. Yields greater than 8 % (EN38), complies with directive ErP 29/125/EC. New levels of filtration and purification, control and optimisation of energy consumption. One- or two-piece smart, plug and play unit (EN232). RANGE Available in sizes and 8 models, the range covers flow rates from 5, to 22, m 3 /h. The range is offered in versions each available, on the fresh side, with right- or left-hand access: : self-regulated energy recovery unit without heating coils, with FEE function for optimisation of energy consumption. ELITE : unit combined with the ELITE module for climatic comfort with the choice of one or a combination of two heating coils: water heating coil, electric heating coil, changeover coil, water cooling coil, direct expansion coil, cold only or reversible. PURE : unit combined with the PURE module incorporating new and patented technology allowing indoor to be purified without regular maintenance. Through its instant double action of pollution/contamination removal action combined with the removal of smells, PURE radically removes micro-organisms, viruses, bacteria, mildew, chemical pollutants and all odorous wastes by a unique and patented physical-chemical process. EDEN : unit coupled with the EDEN module combining the various configurations of the climatic comfort offered in the ELITE and the new treatment of indoor offered by the PURE module. CONSTRUCTION The range together with its associated ELITE, PURE and EDEN modules are designed and manufactured in compliance with the EUROVENT certification processes and meet current European standards (EN1886, EN1353, etc.) to guarantee mechanical strength, sealing, acoustic levels and technical performance. Structure in aluminium profile with thermal breaks using polyamide spacers built into the profile (class TB2 in accordance with EN1886). Corners in reinforced polyamide. Double skin panels 1/1th (Class D1 in accordance with EN1886). Insulation: 5 mm high density 5 mm A1 (M) (L1 and T2 class for tightness of the envelope according to EN1886). External surface: RAL 735 pre-lacquered metal sheet with protective film. Internal surface: galvanized steel. Frame in heavy gauge 3/1 galvanised steel. Modules ELITE, PURE and EDEN on 3/1 galvanised feets. Access to the internal components by pivoting doors with progressive locking handles along with a safety latch on all doors. EQUIPMENT MOTOR FANS Plug fans in epoxy-treated galvanised steel. The design of the range (position of the fans) minimises leaks of return to the blast as much as possible and limits the leakage rate caused by the rotating heat exchanger. Direct drive DC motor with high efficiency electronic commutation (EC) thermal cut-out and speed variation integrated for model 1. Direct drive motor, IE2/IP55, thermal cut-out and frequency converters incorporated on models 13 and 17, synchronous motor with permanent magnet IE3/IP55 and frequency converter for model 22. All models comply with phase 2 (2) of directive ErP 29/125/EC. Several flow modulations are available (see page 213). HEAT EXCHANGER High efficiency rotating heat exchanger in aluminium, with variable speed. Heat exchanger in a rigid frame mounted on slides for easy extraction and maintenance. Rotating - heat exchangers produced by KLINGENBURG which participates in the Eurovent certification programme for the AARE. When used for local high humidity, provide a tray condensate (option) under the rotary exchanger. FILTERS High efficiency F7 Opacimetric filters (large filtering surface) for fresh and exhaust.. The filters are always mounted upstream of components to ensure they are protected. Mounted on runners fitted with lip seals to provide effective tightness. Access to the filters by pivoting doors with progressive locking handles and safety latch. Checking of filter fouling at periods which can be changed in the regulation system and fresh filter fouling pressure switch. Optionally, return filter fouling pressure switch and "J" liquid pressure gauges fitted on the unit. 3-WAYS MODULE As standard, the range is fitted with a motor-driven 3-ways mixing system, using class opposing displacement aluminium profiled blades. The dampers composing this 3-way module are controlled and managed automatically by the regulation system and provide antifreeze, insulation and fire safety functions (damper downstream of the fresh filter), optimisation of energy gains and quality of the indoor ( PURE and EDEN ) on start-up (recirculation) and when the unit is in operation using the FEE principle: Free Energy Efficiency (see features section). PROBES The module is fitted as standard with: Outdoor/fresh temperature probe, supply probe, return temperature probe and CO2 probe. These probes are all fitted and wired in the unit and connected to the regulation system. They carry out all the functions enabling the unit to operate optimally in accordance with the actual requirements of the installation and are involved in the implementation by the regulation system of free-cooling, night-cooling, cold recovery, recirculation and the econological FEE solution (Free Energy Efficiency). ELECTRICAL COMPARTMENT AND REGULATION SYSTEM This sealed compartment incorporated into the unit includes all the electrical components and regulation system. Provided with pivoting doors fitted with progressive closing handles and a safety latch, this compartment contains the electrical control panel, the smart regulation system using and the inverters for the motors (models 13 to 22). The access door to the electrical compartment accommodates a display panel with an IP65 LCD screen for interior or exterior installation, and a lockable switch. The display on the front panel gives access to the settings and setpoints of the regulation system. A fixed strip fitted with grommets allows the unit to be electrically connected providing quick and simple installation. A remote control with features similar to the display panel (at 1m or 1km combined with repeater), or a touch user screen for temperature control, restart, default, etc. functions may be connected to the regulator present in the compartment. (up to 1 m). Weekly internal timers allow operation at two flow rates, programmableas required on site with two setting periods per day for each flow rate. Timer for setting annual holidays and public holidays. Weekly timer for starting/stopping recirculation. P28

3 DOUBLE FLOW UNIT DESCRIPTION The regulation system integrated into the unit enables the various configurations of the ELITE climatic module, the PURE module (indoor quality) and the EDEN module (climatic comfort and indoor quality) to be managed. ELITE EQUIPMENT The ELITE version combines an ELITE module with the same cross-section as the unit enabling heating coils to be incorporated in the system to provide climatic comfort suited to the environmental conditions and the operating requirements of the building. This module can be fitted with: Hot water coil only (H). Hot water coil and direct expansion coil (HDX). Electric heating coil and direct expansion coil (EDX). Cold water coil only (C). Electric heating coil (E). Hot water coil and cold water coil (HC). Electric heating coil and cold water coil (EC). Changeover water coil (CO). Cold direct expansion coil only (DX) or reversible (DXR). The direct expansion coil is managed by the outdoor unit. An interface (optional) to the unit regulation system sends a signal to start the chiller unit. As standard, the ELITE modules incorporating a cold coil or a direct expansion coil are fitted with a STAINLESS STEEL condensate tray mounted on a runner for quick extraction and easy maintenance. In addition, the module incorporates a removable trap connected on the outlet from the condensate tray and connected to a drain on the lower part of the module. These internal components are accessed by means of a door with a handle and a safety latch. PURE EQUIPMENT As standard the regulation is delivered in language MODBUS, WEB and BACNET. Available in optional LON The PURE version combines a PURE module of the same cross-section as the unit to purify the indoor environment by means of an innovative and patented system. Currently indoor is on average 5 to 2 times more polluted than outdoor. However we spend 7 to 8% of our time in closed spaces. This observation reveals the negative impact of indoor pollution on comfort and well-being. This indoor contains polluants, micro-organisms, viruses and mildew in larger concentrations than the outdoor. In addition, the trend to design buildings with low energy consumption accentuates this phenomenon of confinement and concentration of these pollutants. Nowadays, the quality of indoor has become a major public health challenge, one of the subjects most studied by health authorities. Using the innovative, patented and certified CLEARMOTION, technology of the PURE module, the unit has no limit to its application scope: group housing, service sector, hospitals, industry. The technological principle of CLEARMOTION consists of cutting the carbon molecules (polluants, viruses, bacteria, smells, allergens, etc.) which recompose naturally into stable water (H2O), oxygen (O2), nitrogen (N2) and carbon dioxide (CO2) molecules. The contribution made by the innovative technology in the PURE module makes it possible to obtain in its original state. EDEN EQUIPMENT The EDEN version combines an EDEN module of the same cross-section as the unit incorporating within the same module the climatic functions available in the ELITE module and the innovative and patented technology of the PURE module which purifies the indoor environment. This EDEN version is unique and new to the handling and energy recovery unit market and ensures your unit will be able to be used in all types of building and in all climates. FEATURES The range is self-regulating, plug and play and communicates on a MODBUS RS85. Based on the principles of high efficiency (more than 8%) energy recovery (EN38 and EUROVENT certification of the heat exchanger), reductions in CO2 emissions (in compliance with the 2nd step planned in 2 by directive ErP 29/125/EC), performance requirements for conditioning and ventilation systems (EN13779, PSFP less than 1.5), our programme incorporates a complete and innovative system for implementing optimal econological solutions based on temperature criteria (indoor and outdoor) and Indoor Air Quality (IAQ). FEE : FREE ENERGY EFFICIENCY Using the 3-ways module fitted as standard to the range, the FEE function is managed autonomously and automatically and provides maximum optimisation of energy gains. Depending on the outdoor temperature, the blowing setpoint temperature (or ambient temperature of exhaust ), the 3-ways module controlled by modulating servomotors provides partial or total recycling (9% to maintain 1% fresh, adjustable) to limit energy consumption and heat or cold production. This function will also be interlocked to the quality of the extracted through a CO2 probe incorporated within the unit which determines to what extent the FEE function can be used without degrading the indoor quality (threshold 1 ppm in compliance with current regulations). This CO2 setpoint threshold can be adjusted on site. Depending on the situation, the FEE function provides energy savings of more than %. FREE COOLING To optimise the energy contribution from the fresh, the unit is fitted with temperature probes on the outdoor and the ambient of the building (probe on the return ) which are used to control the motor to optimise the speed of the rotating heat exchanger. In summer, when the outdoor temperature drops to less than the indoor temperature, the rotating heat exchanger is stopped and the unit operates using fresh only. COLD RECOVERY During the summer, if the interior temperature is less than the exterior temperature, the rotating heat exchanger operates so as to recover the energy and optimise energy consumption. At this point, the FEE (Free Energy Efficiency) function activates to improve energy savings if the CO2 content of the indoor (threshold 1 ppm adjustable) allows this. *En standard la régulation est livrée en langage MODBUS, WEB et BACNET. Disponible en Lon en option. P29

4 ENERGY RECUPERATION DOUBLE FLOW UNIT DESCRIPTION P21 NIGHT COOLING The night cooling function enables the indoor temperature of the building to be lowered according to the climatic conditions over the last 2 hours. Thus between midnight and 7 a.m. (time slot adjustable), the night cooling function starts if the outside temperature exceeds 22 C (adjustable) during the day (between 6 a.m. and 1 p.m.). Night cooling operates if the outside temperature is between 1 and 18 C (adjustable) and if the exhaust temperature is greater than 18 C (adjustable). In addition, this function has a specific configured ventilation speed set to 85% (adjustable). RECIRCULATION To optimise the energy consumption of the range, the regulation system enables a timer to be set for the recirculation ranges (outside the LS/HS operating times). During this period, the unit starts up with recycled only (fresh and exhaust dampers closed on the 3-ways module) with gradual run-up of the heat exchanger, fans and coils (ELITE and EDEN versions) in order to set the temperature of the heat exchanger and indoor environment. For an PURE or EDEN unit this recirculation function also enables the indoor to be purified before the users of the building arrive. For energy saving reasons, the night cooling function takes priority over the recirculation function. INDOOR AIR QUALITY As standard, the range is fitted with a CO2 probe on the exhaust. This probe allows the 3-ways module to be configured to maintain a suitable CO2 rate. To strengthen indoor quality, the PURE and EDEN versions purify the indoor environment by means of an innovative, patented and certified technology. This technology CLEARMOTION is based on the combination of photocatalysis with a cold plasma. Photocatalysis is a semi-conductor-based process used for purifying and water. The cold plasma is the ionisation of an inert gas by electrical discharge which creates highly-oxidative free radicals which in turn mineralise the pollutants by modifying their chemical structure (destruction of carbon chains). Combining these two technologies prevents the formation of reactive by-products since the cold plasma allows rapid but sometimes incomplete mineralisation compensated by the photocatalysis which provides good mineralisation with a slow kinetic. This is a real innovation, patented with certified results through analyses carried out by the Intertek International Laboratory (microbiological analysis) and the Tera Environnement Laboratory (VOC analysis). This technology CLEARMOTION is the local integration of a dielectric barrier discharge via a silicon matrix. The free radicals thus generated instantaneously degrade any carbon chains inside the treatment chamber which remineralise into stable H2O, O2, N2 and CO2 molecules. These analyses have been able to confirm and certify the decontamination, depollution and deodorisation capabilities of the process employed in the PURE and EDEN ranges. This innovative technology also saves energy since the pressure losses and consumption (max. 3 Pa/33 W for model 22) are negligible considering its efficiency and the flows treated. The operation of the PURE and EDEN modules is managed and controlled by the regulation system of the unit. The technology does not require any regular maintenance. In the event of a fault, an alarm report is displayed on the LCD screen of the unit. An LED panel integrated in the PURE/EDEN module shows each component (lamps, DBD) and indicates which is defective. Thanks to this innovative technology, the PURE and EDEN units can be deployed in all types of building, group housing, service sector, hospitals, professional restaurants, industries, etc. HEAT EXCHANGER FOULING SAFETY SYSTEM To avoid the heat exchanger becoming fouled while the fans are operating and energy recovery is inactive (heat exchanger stopped), the regulation system automatically carries out a rotation of the heat exchanger (average 1 minute per hour). FIRE SAFETY The internal regulation cabinet of the unit has two terminals for connecting a "Fireman's stop" on opening which forces the immediate and complete shutdown of the unit (fans, rotating heat exchanger, etc.) and closes the fire safety damper situated downstream of the fresh filter and the extracted damper. As an option, the unit may be factory-fitted with an optical smoke detector connected to this contact. SMART REGULATION The range and its ELITE, PURE and EDEN versions are plug and play. The regulation system factory-fitted, wired and tested is integrated into a sealed compartment. As standard, the regulation system is supplied in MODBUS BACNET or WEB but can also be provided on request in LON, BACNET, WEB. As standard, the unit is fitted with an LCD IP65 screen on the front panel. As an option, it is possible to connect one and/or another of the following remote controls: LCD remote control with the same features as the front panel screen and which can be moved from 1 m to 1 km (requires repeater option) or limited to 1m if the unit is connected to a BMS. User control with touch screen which can be moved up to 1 m whether or not the unit is connected to a BMS. units are intended for the ventilation and comfort treatment of indoor environments with average humidity. They are not suited to humid environments such as swimming pools, saunas, sea therapy, laundry, etc. When carrying out clean compensation and renewal, the regulation system of the unit acts on the temperature control according to the season. In Winter, the regulation system controls the blowing temperature according to the outdoor temperature (adjustable law). If the external temperature goes over 13 C (setpoint adjustable) the the regulation system goes into control mode on the extracted temperature (setpoint adjustable). For comfort (ELITE/EDEN) use providing heating and/or cooling to the building along with clean renewal, the unit regulation system acts on the temperature control of the extracted from the building (setpoint adjustable) or on the ambient temperature (optional ambient probe). The regulator is fitted with a battery which enables users settings to be maintained in the event of a power cut. Changeover from summer time to winter time is automatic (although this function can be disabled).

5 DIMENSIONS CHARACTERISTICS Dim (mm) A A A B C D E E F F F F F G G G I I J J J J K K M M M M T* 1"1/ 1"1/2 2" 2" T1* 2" 2" 2" 2" T2** 1 1/8 1"1/8 1"1/8 1"3/8 T3** 1"5/8 1"5/8 1"5/8 2"1/8 * Steel tube with gas pitch thread ** Copper tube G-I-J-J1-T: hot water coil (H) G1-I-J-J1-T1: cold water coil (C-CO) G2-I2-J2-J3-T2-T3: irect expansion coil (DX-DXR) SIDE VIEW ELITE MODULE 1 and and 22 PURE MODULE EDEN MODULE TOP VIEW OF FRAME AND FEET MODULES PURE / ELITE AND EDEN 1 and and 22 PURE/ELITE/EDEN MODULE P2

6 ENERGY RECUPERATION CHARACTERISTICS WEIGHT ELITE EDEN PURE Climatic module Climatic module + IAQ* Unit Module IAQ* model (kg) (kg) (kg) (kg) H/E C/CO/DX HC/EC/HDX/EDX H/E C/CO/DX HC/EC/HDX/EDX *: Indoor Air Quality, innovative and patented technology DBD-Lyse ELECTRICAL CHARACTERISTICS Motor Working Protection Thermal ELITE/EDEN Electric Heating (E) Model Voltage Power Current Temp. rating cutout Voltage Protection crnt. (V / Ph / Hz) (kw) (A) ( C /) Class * (V/Ph/Hz) (A) 1 / 3+N / 5 2 x 3,3 kw 2 x 5,2 A -2 / C IP5 / F PTI / 3+N / / 3+N / 5 2 x kw 2 x 8,2 A -2 / C IP55 / F PTC / 3+N / / 3+N / 5 2 x 7,5 Kw 2 x 1,8 A -2 / C IP55 / F PTC / 3+N / / 3+N / 5 2 x kw 2 x 23,2 A -2 / C IP55 / F PTC / 3+N / 5 61 * PTI: Integrated thermal cutout PTC: Thermal protection by PTC probe connected to the regulation system ELECTRIC COILS PERFORMANCES E Electric heating Air flow Fresh temperature C (ELITE - EDEN) coil E model (m 3 /h) (kw) * -2* 1 1 2,75 23,1 22 2,9 22,1 21, ,9 2,8 19,8 2,9 2, ,9 21,1 2, ,2 2,1 19 2,2 19, *: With 3% recycled at 2 C (FEE function of 3-way module) Unit output C FITTED OPTIONS KIT ELITE - EDEN H ELITE - EDEN C/CO RAIN VISOR SOLENOID VALVE Hot water coil Cold/Changeover coil H J K Weight Water rating C 9/7 8/6 6/5 5/ 5/ 7/12 6/ (mm) (mm) (mm) (kg) 1 32/16-1"1/ F - IP5 5/ - 2 F - IP /16-1"1/ F - IP5 5/ - 2 F - IP / - 2"F - IP5 5/ - 2 F - IP / - 2"F - IP5 5/ - 2 F - IP P212 CALADAIR I 61 rue de Saint Véran I 71 MÂCON LOCHÉ I Tél. 33 () Fax 33 () I

7 MODULATION SOLUTIONS The unit has a factory-programmable regulator as standard used to configure the flow modulations described below: HS flow rate Constant LS flow rate Constant HS flow rate LS flow rate flow rate operation 1 or 2 flow rates (LS/HS) as required per fan flow rate + MAC2 EC operation 1 or 2 CONSTANT flow rates as required per fan HS flow rate Constant LS flow rate Constant HS flow rate LS flow rate flow rate + DIVA EC operation PROPORTIONAL ventilation between two flow rates (LS/HS) fan for all fresh operation flow rate + QUATTRO EC operation PROPORTIONAL ventilation between two CONSTANT flow rates per fan for all fresh operation Constant pressure flow rate + LOBBY EC operation CONSTANT PRESSURE ventilation by fan Remote control with LCD display (optional) max 1 m or 1 m with repeater (optional). Same functions as screen on front panel of he unit. User touch screen max. 1m. Functions temperature control, restart, default, etc.touch wall control ref. ED TOUCH Version not compatible SEASON. Max 1 m. CALADAIR I 61 rue de Saint Véran I 71 MÂCON LOCHÉ I Tél. 33 () Fax 33 () I P213

8 ENERGY RECUPERATION FLOW RATE MODULATION Control panel with IP65 LCD display mounted on the front panel of the for adjusting timers, flow rates, temperature (proportional management of the 3-ways module, water or electric heating coils, night over-ventilation) checking and readout of defaults, etc. with FLOW RATE STOP => HS STOP => LS => HS STOP => LS & LS => HS FORCE STOP MODULATION LCD control TIMER TIMER TIMER & Dry contact* "EASY" or remote Regulation à distance at 1 or 2 adjustable or or or or flow rates (LS/HS) Dry contact* Dry contact* Dry contact* & Dry contact* Dry contact* MAC2 EC LCD control TIMER TIMER TIMER & Dry contact* "EASY" or remote Regulation control at 1 or 2 or or or or CONSTANT flow rates Dry contact* Dry contact* Dry contact* & Dry contact* Dry contact* LOBBY LCD control TIMER "EASY" or remote Regulation at control adjustable or CONSTANT PRESSURE or and variable flow rates Dry contact* Dry contact* DIVA EC LCD control TIMER & 1V CO2 probe "EASY" or remote Regulation with control PROPORTIONAL or or ventilation between 2 adjustable flow rates 1V CO2 probe Dry contact* QUATTRO EC LCD control Regulation TIMER & 1V CO2 probe "EASY" or remote with PROPORTIONAL control ventilation or or between 2 CONSTANT adjustable 1V CO2 probe flow rates Dry contact* Standard function built in to the unit Optional accessory not fitted *Dry contact: CDC type remote control/on-off CO2 probe/on-off humidity probe/all types of dry contact, etc. P21

9 ACOUSTIC CHARACTERISTICS The Lpm db(a) curves indicate the sound pressure level measured at m, in free field conditions, with hemispherical distribution on a reflecting plane, disconnecting the exterior fresh intake and stale expulsion ducts and connecting the interior fresh injection and stale extraction ducts. To obtain the overall sound pressure level Lp db(a), at a given distance, add the values below to Lpm Distance (m) 1, Distance weighting db(a) NOTA: Tolerance = Global Values + / - 3 db(a) Acoustic spectra +/- 5 db(a) The LW fresh injection db(a) curves indicate overall sound power emitted at the fresh injection duct. or "Return rejected". To obtain the spectre of acoustic power Lw cond blowing db (A), sides "Fresh blowing" or "Return rejection", add the values below to the acoustic power "Lw cond blowing" read on curves. Downstream acoustic spectrum weighting function"lw cond blower db(a)" Indicated on the curves Frequency 63 Hz 125 Hz 25 Hz 5 Hz 1 Hz 2 Hz Hz 8 Hz Weighting 1 db(a) Weighting 13 db(a) Weighting 17 db(a) Weighting 22 db(a) Curves " Lw cond extraction db (A) " correspond to the global acoustic power shone in girdle sides " Return extraction " and " Fresh input ". To obtain the acoustic spectre of acoustic power Lw cond extraction db ( A ), sides " Return extraction " and " Fresh input ", Add the values below to the acoustic power " Lw cond extraction " read on curves. Upstream acoustic spectrum weighting function "Lw cond extraction db(a)"indicated on the curves Frequency 63 Hz 125 Hz 25 Hz 5 Hz 1 Hz 2 Hz Hz 8 Hz Weighting 1 db(a) Weighting 13 db(a) Weighting 17 db(a) Weighting 22 db(a) To obtain the acoustic spectre NSC db ( A ) (sound level in m in hemispherical open field, device put on the ground on reflecting plan, extremities of the power plant linked with the aspiration and the rejections by girdles of the same sound insulation as this one), to deduct 18 db ( A ) in the value of Lpm. SOLUTIONS GLOBALES WITHOUT Heating coil (coil 1) WITH Water heating coil (H) (coil 1) WITH Electric heating coil (E) (coil 1) COIL (1) COIL (2) WITHOUT Indoor purification WITH Indoor purification WITHOUT Indoor purification WITH Indoor purification WITHOUT Indoor purification WITH Indoor purification CHANGEOVER COLD DIRECT REVERSIBLE WITHOUT COIL (2) COLD COIL C COIL CO EXPANSION COIL DIRECT EXPANSION ONLY DX COIL DXR ELITE C ELITE CO ELITE DX ELITE DXR PURE EDEN C EDEN CO EDEN DX EDEN DXR ELITE H ELITE HC ELITE HDX EDEN H EDEN HC EDEN HDX ELITE E ELITE EC ELITE EDX EDEN E EDEN EC EDEN EDX = Energy recovery unit without heating coil. PURE = Energy recovery unit without heating coil with innovative decontamination/ depollution and deodorising technology for indoor. ELITE = Energy recovery unit with (1) and/or (2) heating coils. EDEN = Energy recovery unit with (1) and/or (2) heating coils + innovative decontamination/depollution and deodorising technology for indoor. coil 1 coil 2 CALADAIR I 61 rue de Saint Véran I 71 MÂCON LOCHÉ I Tél. 33 () Fax 33 () I P2

10 ENERGY RECUPERATION SELECTION CURVES Static pressure (Pa) Batterie électrique Batterie eau chaude Batterie eau froide C-CO Batterie détente directe DX-DXR Loss of load batteries (Pa) Absorbed power (w) by ventilator Efficiency (%) - EN 38 Repeated Air 2 C / 5% % Energie* Econome A B C D E F G Peu économe *Conditions : Tout Conditions: neuf. Débit blowing de souflage flow and et equivalents de reprise équivalents recovery: 6m3 : 1 / mh. 3 Temp. /h. Temp. -1: -1 C/9% C / I 2 I 2 C/5% C / A Lw cond blowing New Air (db (A)) Lw cond extraction Repated Air (db (A)) Lpm (db(a)) P216 CALADAIR I 61 rue de Saint Véran I 71 MÂCON LOCHÉ I Tél. 33 () Fax 33 () I

11 PERFORMANCE CHARACTERISTICS OF 1 HEAT COILS H (ELITE - EDEN) Air inlet ( C) Water ( C/ C) 9/7 8/6 6/5 5/ Water ( C/ C) 7/12 C-CO (ELITE-EDEN) Inlet T ( C-%HR) 6/ 5/ Hot water coil Air flow (m 3 /h) Power (kw)/air out T. ( C) 7,1/81,3 83,5/73, 3/67, 138/62,7 16/58,9 Water flow (l/h)/dp water (kpa) 28/3 368/7 99/1 61/13 76/17 Power (kw)/air out T. ( C),5/81,5 78,8/73,8 17/68,1 13/63,7 1/6,1 Water flow (l/h)/dp water (kpa) 196/3 37/6 7/9 57/12 665/ Power (kw)/air out T. ( C),5/71, 71,3/6,2 96,/59 7/5,9 136/51,5 Water flow (l/h)/dp water (kpa) 178/3 313/5 23/8 516/ 597/13 Power (kw)/air out T. ( C) 37,9/71,5 66,5/6,7 89,7/59,6 19/55,8 126/52,7 Water flow (l/h)/dp water (kpa) 166/2 292/5 39/8 8/1 555/13 Power (kw)/air out T. ( C) 29,5/55,1 52,6/5,3 71,5/6,6 87,6/3,7 12/1,3 Water flow (l/h)/dp water (kpa) 258/5 59/1 625/ 765/21 887/28 Power (kw)/air out T. ( C) 26,9/55,2 7,9/5,7 65/7,3 79,5/,7 92,1/2,5 Water flow (l/h)/dp water (kpa) 235/5 18/8 568/12 69/18 85/23 Power (kw)/air out T. ( C) 2,/1, 36,2/38,1 9,2/35,5 6,2/33,5 69,8/31,8 Water flow (l/h)/dp water (kpa) 35/5 63/1 855/ 15/21 121/28 Power (kw)/air out T. ( C) 17,8/1,6 31,5/38,5 2,7/36,2 52,1/3,5 6,/33 Water flow (l/h)/dp water (kpa) 39/ 57/9 72/13 96/16 15/21 Cold and changeover coil Air flow (m 3 /h) Power (kw)/air out T. ( C-%HR) 21,/1,5-98,2 37/12,7-9,7 9,6/1,2-91,6 6,2/, ,3/16,2-86,8 Water flow (l/h)/dp water (kpa) 366/ 63/5 85/8 13/1 9/12 Power (kw)/air out T. ( C-%HR) 16,6/1,6-98,7 28,3/12,3-96,2 37,6/13,5-93,9 5,3/1,5-91,9 51,9/,2-9,2 Water flow (l/h)/dp water (kpa) 28/2 85/ 6/5 776/7 891/9 Power (kw)/air out T. ( C-%HR) 12,9/1,7-98,7 21,7/12,2-96,3 28,5/13,3-9,1 3,1/1-92,2 38,9/1,6-9,5 Water flow (l/h)/dp water (kpa) 222/3 371/ 89/ 585/ 667/5 Power (kw)/air out T. ( C-%HR) 22,9/9,5-98,1 39,8/,8-9,6 53,5/13,-91, 65,1/1,6-88,8 75,1/,6-86,6 Water flow (l/h)/dp water (kpa) 392/ 683/5 917/9 2/ 129 /1 Power (kw)/air out T. ( C-%HR) 18,1/9,6-98,6 31,1/,5-96,1 1,6/12,8-93,7 5,3/13,7-91,7 57,8/1,5-9 Water flow (l/h)/dp water (kpa) 3/3 53/5 712/6 862/8 991/9 Power (kw)/air out T. ( C-%HR) 1,5/9,7-98,7 2,6/,3-96,2 32,5/12,5-9 39,2/13,3-92,8/1-9,3 Water flow (l/h)/dp water (kpa) 29/3 22/3 558/5 671/5 769/7 Power (kw)/air out T. ( C) 2,7/1,9 37,3/38,8 51,1/36, 62,9/3,5 73,3/32,9 Water flow (l/h)/dp water (kpa) 36/3 68/3 888/ 19/6 127/8 Power (kw)/air out T. ( C) 18,1/2 32,/39,2,2/37 5,/35,3 63,3/33,9 Water flow (l/h)/dp water (kpa) 31/2 563/3 769/5 95/5 /6 DX-DXR with R1A (ELITE-EDEN) Cold direct expansion coil alone and reversible Evap. Temp. ( C) 7 5 Inlet T ( C-%HR) Condensing ( C) Air flow (m 3 /h) Power (kw) 21, 37,2 9,8 6, 69, Air out ( C-%HR) -93,1 13,2-88 1,8-8, ,2 17-8,3 Power (kw) 17,3 3,1 8,6 55,9 Air out ( C-%HR) 1,-9,9 12,3-91,1 13,6-88,5 1,5-86,6,3-85 Power (kw) 1,2 2,6 32,8 39,8 5,5 Air out ( C-%HR) 1,2-95,1,8-91, 12,9-88,8 13,7-86,9 1,-85, Power (kw) 23,9 1,7 55,9 67,7 77, Air out ( C-%HR) 9,3-92,6,9-87,5 13,6-8,1-81,7 16,1-79,8 Power (kw) 19,8 3, 6,3 55,9 6,1 Air out ( C-%HR) 8,8-9,6 1,9-9,7 12, ,-86,1 1,3-8,6 Power (kw) 16,8 29,1 38,9 7,1 5 Air out ( C-%HR) 8,-9,8 1,3-9,9,6-88,3 12,6-86, 13,-8,9 Power (kw) 17,5 31,8 5,7 6,2 Air out ( C) 37,2 3,7 32,9 31, 3,2 Power (kw),1 27,3 37,8 6,9 55,1 Air out ( C) 37,5 35, 33,8 32,5 31,5 P217

12 ENERGY RECUPERATION SELECTION CURVES Static pressure (Pa) Batterie électrique Batterie eau chaude Batterie eau froide C-CO Batterie détente directe DX-DXR Loss of load batteries (Pa) Absorbed power (w) by ventilator Efficiency (%) - EN 38 Repeated Air 2 C / 5% % Energie* Econome A B C D E F G Peu économe Conditions: blowing flow and equivalents recovery: 6m3 / h. Temp. -1 C / 9% I 2 C / 5% A Lw cond blowing New Air (db (A)) Lw cond extraction Repated Air (db (A)) Lpm (db(a)) P218 CALADAIR I 61 rue de Saint Véran I 71 MÂCON LOCHÉ I Tél. 33 () Fax 33 () I

13 PERFORMANCE CHARACTERISTICS OF 13 HEAT COILS H (ELITE - EDEN) Air inlet ( C) Water ( C/ C) 9/7 8/6 6/5 5/ Water ( C/ C) 7/12 C-CO (ELITE-EDEN) Inlet T ( C-%HR) 6/ 5/ Hot water coil Air flow (m 3 /h) Power (kw)/air out T. ( C) 69,/8,1 15/7 136/69,1 163/65,1 187/61,7 27/58,9 Water flow (l/h)/dp water (kpa) 36/5 65/9 6/13 719/17 82/22 919/27 Power (kw)/air out T. ( C) 65,6/8,2 99,5/7, 128/69,7 /66 176/62,8 196/6,1 Water flow (l/h)/dp water (kpa) 289/5 38/8 566/ 677/16 776/2 865/2 Power (kw)/air out T. ( C) 59,6/7,3 9,2/6,9 6/6,5 139/57 9/5,1 177/51,7 Water flow (l/h)/dp water (kpa) 262/5 396/8 51/ 61/13 698/17 778/21 Power (kw)/air out T. ( C) 55,8/7,5 8,2/65,3 18/61,2 129/57,9 18/55,2 165/52,8 Water flow (l/h)/dp water (kpa) 25/5 37/7 76/1 568/12 65/ 723/18 Power (kw)/air out T. ( C) 3,5/5,3 66,/5,6 85,9/7,6 13/5,2 8/3,1 132/1,3 Water flow (l/h)/dp water (kpa) 38/8 58/13 751/2 91/28 13/3 1/2 Power (kw)/air out T. ( C) 39,7/5,5 6,/51,1 78,2/8,3 93,6/6,1 17/,2 12/2,5 Water flow (l/h)/dp water (kpa) 37/7 528/12 683/17 818/2 938/3 15/35 Power (kw)/air out T. ( C) 3,1/,9 5,8/38,3 59,2 /36,3 71/3,6 81,/33,1 9,9/31,9 Water flow (l/h)/dp water (kpa) 522/8 795/13 13/2 123/28 12/35 8/2 Power (kw)/air out T. ( C) 26,2/1,1 39,8/38,8 51,/36,9 61,6/35, 7,6/3,2 78,6/33,1 Water flow (l/h)/dp water (kpa) 56/6 693/ 895/16 17/22 123/28 137/32 Cold and changeover coil Air flow (m 3 /h) Power (kw)/air out T. ( C-%HR) 31,7/1,7-97,5 7,/12,3-9,8 6,7/13,6-92,3 72,3/1,6-9,1 82,6/,-88,2 91,9/16,1-86,5 Water flow (l/h)/dp water (kpa) 53/5 81/7 1/9 12/12 12 /16 8/18 Power (kw)/air out T. ( C-%HR) 2,6/1,7-98,2 36,5/12,1-96,2 6,/13-9, 55/13,8-92,7 62,5/1,5-91,3 69,3/-9 Water flow (l/h)/dp water (kpa) 22/3 626/ 796/6 9/9 17/9 9/ Power (kw)/air out T. ( C-%HR) 19,3/1,8-98,3 28,2/12-96, 35,6/12,8-9,6 1,9/13,5-93 7,5/1-91,6 52,5/1,5-9,3 Water flow (l/h)/dp water (kpa) 331/3 83/ 61/ 719/5 8/7 /8 Power (kw)/air out T. ( C-%HR) 33,9/9,8-97, 51/,5-9,7 65,5/12,8-92,1 78/13,8-89,9 89,2/1, ,3/,-86,3 Water flow (l/h)/dp water (kpa) 581/ 873/8 2/1 13/1 3/18 17/2 Power (kw)/air out T. ( C-%HR) 26,9/9,7-98,2,1/,2-96,1 51,2/12,2-9,2 6,8/13,1-92,5 69,3/13,8-91,1 76,9/1,-89,8 Water flow (l/h)/dp water (kpa) 62/ 687/5 877/8 1/9 9/ 132/1 Power (kw)/air out T. ( C-%HR) 21,6/9,8-98,3 31,9/-96,3,5/12-9, 7,8/12,7-92,8 5,2/13,3-91, 6/13,8-9,1 Water flow (l/h)/dp water (kpa) 371/ 57/5 69/5 819/7 93/9 13/9 Power (kw)/air out T. ( C) 3,6/1,5 7,1/39,1 61,3/37,2 7/35,5 85,3/3,1 95,5/32,9 Water flow (l/h)/dp water (kpa) 532/3 819/3 17/5 129/7 18/8 166/1 Power (kw)/air out T. ( C) 26,7/1,6,9/39, 53,2/37,7 6/36,2 73,8/35 82,5/3 Water flow (l/h)/dp water (kpa) 63/3 7/ 925/ 1/6 128/7 13/8 DX-DXR with R1A (ELITE-EDEN) Cold direct expansion coil alone and reversible Evap. Temp. ( C) 7 5 Inlet T ( C-%HR) Condensing ( C) Air flow (m 3 /h) Power (kw) 31,3 6,6 59, 69,8 79,2 87,2 Air out ( C-%HR),-92 13,2-88,2 1,5-85,5,6-83, 16,5-81,7 17,2-8,3 Power (kw) 25, 37,7 8 56,6 6,1 7,8 Air out ( C-%HR) 1,8-9,1 12,2-91,2 13,3-89,1 1,2-87,5 1,9-86,1,-85 Power (kw) 2,9 31,1 39,6 6, ,3 Air out ( C-%HR) 1,-9,3,7-91,5 12,6-89, 13,3-87,7 1-86, 1,5-85,3 Power (kw) 35 52,1 66,2 77,9 88,1 96,6 Air out ( C-%HR) 9,8-91,5,8-87,7 13,-85 1,6-82,9,6-81,2 16,-79,9 Power (kw) 29 3,1 5,9 6,9 73,2 8,6 Air out ( C-%HR) 9,2-93,8 1,8-9,8 12,1-88, ,9-85,7 1,6-8,6 Power (kw) 2,6 36,5 6,6 5,9 62, 68,7 Air out ( C-%HR) 8,8-9 1,3-91,1, ,2-87,3 12, ,5-8,8 Power (kw) 25,9 52,5 63,7 7 83, Air out ( C) 36,8 3,9 33, 32,1 31,1 3,2 Power (kw) 22,3 3, 5,1 5,8 63,5 71,6 Air out ( C) 37,2 35,6 3,3 33,2 32,2 31,5 P219

14 ENERGY RECUPERATION SELECTION CURVES Static pressure (Pa) Batterie électrique Batterie eau chaude Batterie eau froide C-CO Batterie détente directe DX-DXR Loss of load batteries (Pa) Absorbed power (w) by ventilator Efficiency (%) - EN 38 Repeated Air 2 C / 5% Lw cond blowing New Air (db (A)) Lw cond extraction Repated Air (db (A)) % Energie* Econome A B C D E F G Peu économe Conditions: blowing flow and equivalents recovery: 6m3 / h. Temp. -1 C / 9% I 2 C / 5% A Lpm (db(a)) P22 CALADAIR I 61 rue de Saint Véran I 71 MÂCON LOCHÉ I Tél. 33 () Fax 33 () I

15 PERFORMANCE CHARACTERISTICS OF 17 HEAT COILS H (ELITE - EDEN) Air inlet ( C) Water ( C/ C) 9/7 8/6 6/5 5/ Water ( C/ C) 7/12 C-CO (ELITE-EDEN) Inlet T ( C-%HR) 6/ 5/ Electric coil Air flow (m 3 /h) Power (kw)/air out T. ( C) 19/75,9 7/69, 197/6, 231/6, 262/57 Water flow (l/h)/dp water (kpa) 79/5 69/6 867/1 12/12 6/ Power (kw)/air out T. ( C) 13/76,2 17/7,1 185/65,3 218/61, 26/58,3 Water flow (l/h)/dp water (kpa) 52/ 65/6 816/9 96/12 19/13 Power (kw)/air out T. ( C) 92,9/66,5 133/6,7 167/56,3 196/52,8 222/9,9 Water flow (l/h)/dp water (kpa) 8/3 585/5 73/7 861/1 97/13 Power (kw)/air out T. ( C) 86,7/66,8 12/61,3 5/57,2 182/53,9 26/51,2 Water flow (l/h)/dp water (kpa) 381/ 55/6 682/7 81/9 9/ Power (kw)/air out T. ( C) 68,3/51,8 98,7/7,9 12/77,8 16/2,2 166/,2 Water flow (l/h)/dp water (kpa) 597/5 863/1 19/1 128/19 15/2 Power (kw)/air out T. ( C) 62,2/52,2 89,7/8,5 3/5,6 133/3,3 1/1,1 Water flow (l/h)/dp water (kpa) 5/6 78/9 986/12 6/16 132/2 Power (kw)/air out T. ( C) 7,1/39,1 68/36, 85,5/3,2 11/32,5 /31 Water flow (l/h)/dp water (kpa) 819/5 8/1 19/1 175/1 198/2 Power (kw)/air out T. ( C) 1/39,5 58,9/37 7/35,1 87,1/33,6 98,5/32,3 Water flow (l/h)/dp water (kpa) 713/5 12/8 129/12 1/ 171/18 Cold and changeover coil Air flow (m 3 /h) Power (kw)/air out T. ( C-%HR) 5,7/,-96 72,5/13,1-92,7 9,7/1,3-9 16/,3-87,7 12/16,2-85,7 Water flow (l/h)/dp water (kpa) 869/8 12/13 6/18 183/2 26/3 Power (kw)/air out T. ( C-%HR) 39,/,2-97,1 55,8/12,6-9,7 69,5/13,6-92,6 81,2/1,-9,8 91,5/-89,3 Water flow (l/h)/dp water (kpa) 675/5 957/1 9/12 139/16 7/18 Power (kw)/air out T. ( C-%HR) 3,9/,2-97,2 3,2/12,-9,9 53,/13,3-92,9 62,1/13,9-91,2 69,7/1,5-89,6 Water flow (l/h)/dp water (kpa) 529/5 71/6 916/9 17/1 12/23 Power (kw)/air out T. ( C-%HR) 5,2/1,5-95,8 77,8/12,3-92,6 97,7/13,6-89,8 1/1,7-87, 13/,5-85, Water flow (l/h)/dp water (kpa) 929/9 133 / 167/21 197/28 223/33 Power (kw)/air out T. ( C-%HR) 3,1/1, ,2/,8-9,6 76,/12,8-92, 89,5/13,7-9,7 11/1,-89,1 Water flow (l/h)/dp water (kpa) 738/6 15/1 131/1 /19 173/22 Power (kw)/air out T. ( C-%HR) 3,6/1,3-97,1 8,8/,5-9,8 6,6/12,5-92,7 7,6/13, ,/13,8-89, Water flow (l/h)/dp water (kpa) 593/ 837/7 1/9 121/12 136/ Power (kw)/air out T. ( C) 9,1/,3 71,7/37,8 91,1/35,7 18/3 123/32,6 Water flow (l/h)/dp water (kpa) 853/ 125/7 8/9 188/13 21/16 Power (kw)/air out T. ( C) 2,8/,5 62,3/38,3 79/36, 93,6 /35 16/33,7 Water flow (l/h)/dp water (kpa) 73/ 18/6 137/7 163/1 185/12 DX-DXR with R1A (ELITE-EDEN) Cold direct expansion coil alone and reversible Evap. Temp. ( C) 7 5 Inlet T ( C-%HR) Condensing ( C) Air flow (m 3 /h) Power (kw) 8,9 69,9 87, Air out ( C-%HR) 12,5-89,7 1,2-85,9,-83,2 16,-81,1 17,2-79,5 Power (kw) 39, ,9 92,6 Air out ( C-%HR),7-92, 13,1-89,5 1,1-87,3 1,9-85,7,5-8,3 Power (kw) 32,2 5, ,9 75,2 Air out ( C-%HR),3-92,6 12,5-89,9 13,-87, ,6-8,7 Power (kw) 5,9 78, 98, Air out ( C-%HR) 1,9-89,2 12,9-85,3 1,2-82,6,-8,6 16,3-78,9 Power (kw) 5, 6,6 8, Air out ( C-%HR) 1,1-92, ,9-86,9 13,8-85,2 1,5-83,9 Power (kw) 38,1 5, 67,9 79,6 9 Air out ( C-%HR) 9,7-92,2,1-89,3 12,1-87,2 12,9-85,5 13,6-8,2 Power (kw) 1,1 6, 77,3 92,3 16 Air out ( C) 35,6 33,6 32 3,7 29,6 Power (kw) 35, 51,9 66, 79,2 9,8 Air out ( C) 36,1 3, 33 31,9 3,9 P221

16 ENERGY RECUPERATION SELECTION CURVES Static pressure (Pa) Batterie électrique Batterie eau chaude Batterie eau froide C-CO Batterie détente directe DX-DXR Loss of load batteries (Pa) Absorbed power (w) by ventilator Efficiency (%) - EN 38 Repeated Air 2 C / 5% Lw cond blowing New Air (db (A)) Lw cond extraction Repated Air (db (A)) Lpm (db(a)) % Energie* Econome A B C D E F G Peu économe Conditions: blowing flow and equivalents recovery: 6m3 / h. Temp. -1 C / 9% I 2 C / 5% A P222 CALADAIR I 61 rue de Saint Véran I 71 MÂCON LOCHÉ I Tél. 33 () Fax 33 () I

17 5 7 5/ 6/ 7/12 5/ 6/5 8/6 9/7 PERFORMANCE CHARACTERISTICS OF 22 HEAT COILS H (ELITE - EDEN) Electric coil Water ( C/ C) Air inlet ( C) Air flow (m 3 /h) Power (kw)/air out T. ( C) 131/76,2 195/69,1 27/63,7 292/59,5 332/56 Water flow (l/h)/dp water (kpa) 577/ 857/9 19/12 129/17 16/21 Power (kw)/air out T. ( C) 12/76,5 183/69,8 233/6,6 275/6,6 312/57,3 Water flow (l/h)/dp water (kpa) 55/5 88/8 13/ 121/ 137/19 C-CO (ELITE-EDEN) Cold and changeover coil Water ( C/ C) Inlet T ( C-%HR) Power (kw)/air out T. ( C) 2/66,8 166/6,5 21/55,8 28/52,1 281/9,1 Water flow (l/h)/dp water (kpa) 92/5 728/7 922/ 19/13 123/16 Power (kw)/air out T. ( C) 15/67,1 /61,1 195/56,7 23/53,2 261/5, Water flow (l/h)/dp water (kpa) 59/ 678/6 858/9 11/ 1/1 Power (kw)/air out T. ( C) 82,3/52 123/7,7 6/,3 185/1,7 21/39,5 Water flow (l/h)/dp water (kpa) 719/7 17/13 137/2 162/26 18/32 Power (kw)/air out T. ( C) 75/52,3 2/8,3 12/5,3 168/2,8 191/,9 Water flow (l/h)/dp water (kpa) 655/6 975/ 12/17 17/22 167/27 Power (kw)/air out T. ( C) 56,8/39,3 8,5/36,2 18/33,9 127/32,1 1/3,6 Water flow (l/h)/dp water (kpa) 987/7 17/13 187/2 221/26 251/32 Power (kw)/air out T. ( C) 9,/39,6 73,3/36,9 93,2/3,9 /33,3 125/31,9 Water flow (l/h)/dp water (kpa) 86/5 127/ 162/ 191/21 217/25 Air flow (m 3 /h) Power (kw)/air out T. ( C-%HR) 61,/,3-96 9,7/13,1-92, 1/1,-89, 136/,5-87 /16,-8,9 Water flow (l/h)/dp water (kpa) 15/9 6/16 197/25 232/32 263/ Power (kw)/air out T. ( C-%HR) 8/,1-97,1 7/12,6-9, 88,2/13,7-92,2 1/1,5-9,3 7/,2-88,7 Water flow (l/h)/dp water (kpa) 823/7 12/ 1/17 178/21 21/26 Power (kw)/air out T. ( C-%HR) 37,7/,1-97,2 5,/12,-9,7 68,1/13,3-92,5 79,6/1-9,6 89,6/1,6-89 Water flow (l/h)/dp water (kpa) 66/ 933/8 7/ 137/1 /17 Power (kw)/air out T. ( C-%HR) 65,7/1,-95,8 97,/12,3-92,2 12/13,7-89,2 16/1,8-86,7 166/,8-8,6 Water flow (l/h)/dp water (kpa) 3/1 167/19 212/29 251/37 28/6 Power (kw)/air out T. ( C-%HR) 52,3/1, ,8/,8-9,3 97/12,9-92 /13,8-9,1 129/1,6-88,5 Water flow (l/h)/dp water (kpa) 897/8 132/ /19 196/25 221/3 Power (kw)/air out T. ( C-%HR) 2,2/1,1-97,1 61,/,5-9,5 77,1/12,5-92,3 9,2/13,3-9, 12/13,9-88,8 Water flow (l/h)/dp water (kpa) 723/5 15/9 132/13 7/16 175/2 Power (kw)/air out T. ( C) 59,1/, 89,3/37,7 1/35,5 137/33,7 6/32,2 Water flow (l/h)/dp water (kpa) 13/5 5/8 199/13 238/17 271/21 Power (kw)/air out T. ( C) 51,5/,7 77,6/38,2 99,5/36,2 8/3,6 135/33,3 Water flow (l/h)/dp water (kpa) 896/ 135/8 173/1 26/1 235/16 DX-DXR with R1A (ELITE-EDEN) Cold direct expansion coil alone and reversible Evap. Temp. ( C) Inlet T ( C-%HR) Condensing ( C) Air flow (m 3 /h) Power (kw) 58,6 85, Air out ( C-%HR) 12,5-89,5 1,-95,3,8-82, 16,8-8,3 17,7-78,6 Power (kw) 7,2 68,7 86, Air out ( C-%HR),7-92,2 13,3-89 1,-86,8,2-85,9-83,6 Power (kw) 38,6 56,3 7,8 83,1 93, Air out ( C-%HR),3-92,5 12,6-89,3 13,6-87,1 1,3-85,3 1,9-8 Power (kw) 65,7 96, Air out ( C-%HR) -88,9 13,1-8,7 1,7-81,9,9-79,7 16,8-78,1 Power (kw) 5,1 79, Air out ( C-%HR) 1,2-91, ,5 13,2-86,3 1,2-8,6-83,2 Power (kw) 5,7 66,8 8 98,6 1 Air out ( C-%HR) 9,7-92,1,3-88,8 12,-86,6 13,3-8,9 1-83,5 Power (kw) 9,2 7,5 96, Air out ( C) 35,5 33,3 31,5 3,2 29 Power (kw) 2,3 6 82,7 99,2 Air out ( C) 36 3,1 32,6 31,5 3,5 P223

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0

More information

Outdoor air treatment units

Outdoor air treatment units Outdoor air treatment units A +++ A ++ A + A B C D ErP Fresh Air Unit The FAU series of outdoor air treatment units, with Lossnay enthalpic energy recovery module, direct expansion coil and integrated

More information

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

YKN2open A R C 032 A B

YKN2open A R C 032 A B york air-conditioning products ACTIVA Rooftop ARC-ARG-ARH-ARD A complete range from 17 kw up to 40 kw YKN2open Features High efficiency EER and COP Low noise level EC supply fan All configurations: Cooling

More information

VENTILATION AIR CONDITIONING AIR CLEANING HEATING

VENTILATION AIR CONDITIONING AIR CLEANING HEATING Heat Recovery Units VENTILATION AIR CONDITIONING AIR CLEANING HEATING Cross flow heat recovery units Applications New Designed for energy saving and indoor air quality control within ventilation systems.

More information

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION Available range Unit type IH Heat pump IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS

More information

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features ACTIVA Rooftop ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw YKN2open Features High efficiency EER and COP Low noise level All configurations: Cooling only, Cooling + gas, Heating, Heating +

More information

CI/SfB (57.7) 1st edition

CI/SfB (57.7) 1st edition CI/SfB (57.7) 1st edition Vent-Axia Sentinel Multivent Wholehouse Mechanical Extract Ventilation System Ventilation Lo-Carbon Energy saving solutions Sentinel Multivent continuous mechanical extract ventilation,

More information

HITACHI Modular Chiller Solutions

HITACHI Modular Chiller Solutions Cooling Capacity 95kW - 1920kW Heating Capacity 92kW - 2384kW HITACHI Modular Chiller Solutions Giving you complete control The benefits of our unique modular design Projects change and develop over time.

More information

HIGH EFFECTIVENESS ENERGY RECOVERY

HIGH EFFECTIVENESS ENERGY RECOVERY PRICE RegenCore HIGH EFFECTIVENESS ENERGY RECOVERY PRC / PRCLC PRICE REGENCORE The Price RegenCore is a high effectiveness energy recovery unit. The RegenCore recovers sensible energy during both heating

More information

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

Water terminals from 360 to 1598 m3/h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw

Water terminals from 360 to 1598 m3/h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw Water terminals from 360 to 1598 m3/h from 1.4 to 9.6 kw SysQuare Chilled water cassettes from 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings ErP 2018 OFFICES HOSPITAL 6 sizes

More information

Water terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw

Water terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw Water terminals from 360 to 1598 m 3 /h SysQuare Chilled water cassettes from 1.4 to 9.6 kw from 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings ErP 2018 OFFICES HOSPITAL 6

More information

Water terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw

Water terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw Water terminals from 360 to 1598 m 3 /h SysQuare Chilled water cassettes from 1.4 to 9.6 kw from 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings ErP 2018 OFFICES HOSPITAL 6

More information

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM YORK UNITIZED ENERGY RECOVERY VENTILATORS Regardless of building type or rating system, today s building must be as energy

More information

JONIX MATE NON THERMAL PLASMA TECHNOLOGY

JONIX MATE NON THERMAL PLASMA TECHNOLOGY Food Technology JONIX MATE NON THERMAL PLASMA TECHNOLOGY MOBILE MEDICAL DEVICE FOR INDOOR AIR PURIFICATION AND DECONTAMINATION MADE IN ITALY TECNOLOGIA JONIX uses the advanced oxidation process to decontaminate

More information

Integrated Air Conditioning System

Integrated Air Conditioning System Integrated Air Conditioning System a smart solution for every building Contents TVR System 03 TVR System Advantage 04 TVR System Applications 05 Features - Inverter System 07 Features - Higher Reliability

More information

Advanced Rooftop FLEXY II The packaged Air Handling Unit solution. Providing indoor climate comfort

Advanced Rooftop FLEXY II The packaged Air Handling Unit solution. Providing indoor climate comfort Advanced Rooftop FLEXY II The packaged Air Handling Unit solution Providing indoor climate comfort We have the solution We help you to choose the easiest system: Whatever the nature of the building to

More information

ELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor

ELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor Technical Bulletin BT16N008GB-04 ELFOSpace WALL Water terminal unit for indoor installation, wall-mounted CFW 00.0 021.0 RANGE DC Brushless Motor High standards of efficiency and low noise New design Electronic

More information

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

Rooftops High performance, proven reliability and easy installation

Rooftops High performance, proven reliability and easy installation Rooftops High performance, proven reliability and easy installation 1 Airfinity Rooftops Comfort and economy When it comes to installing and maintaining an HVAC system, every cent counts. From your initial

More information

Nilan VPL Active heat recovery and cooling (air/air)

Nilan VPL Active heat recovery and cooling (air/air) M a r k e t l e a d i n g c o m m e r c i a l a n d d o m e s t i c v e n t i l at i o n w i t h h e at r e c o v e r y Nilan 31-125 Active heat recovery and cooling (air/air) Nilan 31-125 Commercial ventilation

More information

The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1.

The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1. PAGE 1 of 5 1.1. REFERENCE STANDARDS 1.1.1. The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1. 1.1.2. Unit shall be designed to conform to ASHRAE 15. 1.1.3. Unit

More information

CLASS I MICROBIOLOGICAL SAFETY CABINET - BIO 1

CLASS I MICROBIOLOGICAL SAFETY CABINET - BIO 1 CLASS I MICROBIOLOGICAL SAFETY CABINET - BIO 1 PRODUCT SHEET NO. 101 VERSION 2.0 COMPACT HIGHLY SPECIFIED, HIGH PERFORMANCE CLASS I MICROBIOLOGICAL SAFETY CABINETS Applications Handling of biological agents

More information

Peace of mind at all times DAISEIKAI 9. hatever you need

Peace of mind at all times DAISEIKAI 9. hatever you need Peace of mind at all times DAISEIKAI 9 hatever you need DAISEIKAI 9 DAISEIKAI 9 Choose the ultimate in comfort A+++ ratings in both cooling and heating for peerless energy efficiency Make a positive impact

More information

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians Data 924-2 7/12/05 EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians Features Complete sample-conditioning

More information

ROOF TOP PACKAGE UNITS

ROOF TOP PACKAGE UNITS ROOF TOP PACKAGE UNITS Inverter compressors, EC fans, double skin construction package units designed to suit your project requirements SMART PACKAGE UNITS Delivering an extensive range, with capacities

More information

Gitie. A CHOICE SMARTER than solar systems. Trivalent integrated outdoor package

Gitie. A CHOICE SMARTER than solar systems. Trivalent integrated outdoor package ing l o.. Air is enough. ction and co du ro for heating, domestic hot water p A CHOICE SMARTER than solar systems Gitie Trivalent integrated outdoor package with absorption heat pump powered by natural

More information

Characteristics Mechanical strength Air leakage Filter by-pass leakage Thermal transmittance Thermal bridge factor

Characteristics Mechanical strength Air leakage Filter by-pass leakage Thermal transmittance Thermal bridge factor Climaciat AIRCLEAN Ultra-cleanliness has a name Climaciat AIRCLEAN SANTE Healthcare has its experts Air flow: 1 000 to 60 000 m 3 /h Characteristics Mechanical strength Air leakage Filter by-pass leakage

More information

Largo & Allegro. Air Compressors. Largo & Allegro

Largo & Allegro. Air Compressors. Largo & Allegro Largo & Allegro Air Compressors Largo 110-160 & Allegro 110-180 ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 85 years of industrial experience. It is our ambition to offer

More information

YOUR AIR HANDLING SOLUTIONS

YOUR AIR HANDLING SOLUTIONS YOUR AIR HANDLING SOLUTIONS 100% CUSTOM MADE ULTRA CLEAN HIGH PRODUCT LIFE SPAN ENERGY SAVING SODISTRA ZI Nord de Bazouges I 2 rue Gustave Eiffel 53200 Château-Gontier Tel sodistra.com info@sodistra.fr

More information

indoor air quality and energy saving TECHNICAL DATA FAI-ED H/V VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

indoor air quality and energy saving TECHNICAL DATA FAI-ED H/V VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS indoor air quality and energy saving TECHNICAL DATA FAI-ED H/V VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS FAI-ED Is a Non Residential Ventilation Unit (NRVU) EQUIPPED Equipped

More information

RHA TECNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

RHA TECNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N A RE F S E -FRIEND Y R E IG RA N T G A-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L RHA C TECNICAL MANUAL 1 2 TABLE OF CONTENTS THIS MANUAL IS DIVIDED INTO SECTIONS. THE NAMES APPEAR IN THE

More information

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that.

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that. Set Free Modular FSXN Engineering for tomorrow. And the tomorrow after that. 0 03 Introducing a new addition to Hitachi s Set Free range of VRF air conditioning units - enhancing efficiency and user experience

More information

Air Cooled Packaged Air Conditioning

Air Cooled Packaged Air Conditioning Cooling Capacity 11.6kW - 193.0kW Heating Capacity 10.8kW - 213.0kW eco series Packaged Air Conditioning Giving you complete control More than just another air conditioning company. temperzone is dedicated

More information

Water chiller / Heat pump. Aquaciat Power. Sustainable power NA D

Water chiller / Heat pump. Aquaciat Power. Sustainable power NA D Water chiller / Heat pump Aquaciat Power Sustainable power u n i v e r s a l c o m f o r t NA 07.40 D Aquaciat power When Ciat brings together Discover Aquaciat Power, a range that combines the best technology

More information

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection A BINDER FD series Avantgarde.Line heating oven is always used when fast drying and sterilization is required. Thanks to

More information

MPE 4-76 kw. Outdoor packaged unit. Air/water chillers and heat pumps MPE. Efficiency under all operating conditions. 152 galletti.

MPE 4-76 kw. Outdoor packaged unit. Air/water chillers and heat pumps MPE. Efficiency under all operating conditions. 152 galletti. Air/water chillers and heat pumps MPE Outdoor packaged unit MPE - kw Efficiency under all operating conditions Rotary compressor Plus Scroll compressor R-0A R-0A refrigerant Cooling only Cooling / Heating

More information

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH Wuhan Cubic Optoelectronics Co.,Ltd ADD:Fenghuang No.3 Road, Fenghuang Industrial Park,Eastlake Hi-tech Development Zone, Wuhan, 430205, China TEL:+86-27-81628827

More information

IT COOLING CHILLERS. NEW GENERATION OF AIR COOLED CHILLERS FOR IT COOLING APPLICATIONS. CAPACITY RANGE kw, SCROLL COMPRESSORS AND R410A

IT COOLING CHILLERS. NEW GENERATION OF AIR COOLED CHILLERS FOR IT COOLING APPLICATIONS. CAPACITY RANGE kw, SCROLL COMPRESSORS AND R410A IT COOLING CHILLERS / NEW GENERATION OF AIR COOLED CHILLERS FOR IT COOLING APPLICATIONS. CAPACITY RANGE 39-795 kw, SCROLL COMPRESSORS AND R410A IT COOLING CHILLERS / THE KEY SOLUTION FOR YOUR DATA CENTER

More information

Carisma CRS-ECM. High Pressure Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

Carisma CRS-ECM. High Pressure Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board Carisma CRS-ECM igh Pressure Fan Coil Unit with EC rushless Electronic Motor and Inverter oard Range includes 3 air rates (from 3 to 14 m 3 /h) each equipped with 3 or 4 row coil and with the possibility

More information

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V Rollair Air Compressors ROLLAIR 150E-150-180-220 AND ROLLAIR 150V-180V-240V Worthington Creyssensac Driven by technology. Designed by experience. Worthington Creyssensac has over 145 years of industrial

More information

RadiFit EC centrifugal fans. Compact, efficient, easily upgraded.

RadiFit EC centrifugal fans. Compact, efficient, easily upgraded. RadiFit EC centrifugal fans. Compact, efficient, easily upgraded. Fits, saves and makes sense! Our RadiFit range of centrifugal fans with scroll housing and backward curved blades is the new system solution

More information

Report on thermal cooling system implementation and performance

Report on thermal cooling system implementation and performance SUSTAINABLE ENERGY SYSTEMS Report on thermal cooling system implementation and performance Organisation name of lead contractor for this deliverable: ATC POLYCITY DD 2C.1 TREN/05FP6EN/S07.43964/513481

More information

I S O. Eco-Smart Energy Recovery Ventilator

I S O. Eco-Smart Energy Recovery Ventilator I S O I S O 9 0 0 1 1 4 0 0 1 Eco-Smart Energy Recovery Ventilator What s Eco-Smart? Holtop has manufactured heat and energy recovery ventilation products for over 12 years. We pay high attentions on the

More information

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane CLCF Climate Changer for comfort applications Next generation air handling performance from Trane Customized performance and maximum comfort at minimum cost For many years Trane has been a global leader

More information

ROOF TOP SPACE. SELF-CONTAINED REVERSIBLE AIR-AIR UNITS OF 23 TO 281 kw EVERY EFFICIENT SOLUTION FOR UNIVERSAL COMFORT NA C

ROOF TOP SPACE. SELF-CONTAINED REVERSIBLE AIR-AIR UNITS OF 23 TO 281 kw EVERY EFFICIENT SOLUTION FOR UNIVERSAL COMFORT NA C C O M F O R T A I R Q U A L I T Y E N E R G Y O P T I M I S A T I O N ROOF TOP SPACE SELF-CONTAINED REVERSIBLE AIR-AIR UNITS OF 23 TO 281 kw EVERY EFFICIENT SOLUTION FOR UNIVERSAL COMFORT NA. 0816 C SPACE

More information

Rebel commercial packaged rooftop systems

Rebel commercial packaged rooftop systems Rebel commercial packaged rooftop systems Advanced technologies propel performance and energy savings to uncommon levels 3-28 tons Rebel features and benefits 18 13 6 5 3 6 4 43% Energy Savings 5 11 12

More information

Rebel commercial packaged rooftop systems

Rebel commercial packaged rooftop systems Rebel commercial packaged rooftop systems Advanced technologies propel performance and energy savings to uncommon levels 3-28 tons Capitalize with 43% more energy savings If you are a commercial building

More information

Handling Units. Air. D-AHU Professional AIR FLOW RATE 1, ,000m 3 /h DAME

Handling Units. Air. D-AHU Professional AIR FLOW RATE 1, ,000m 3 /h DAME Air Handling Units The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin. Daikin has compiled the content of this leaflet to the best of its knowledge.

More information

WATER CHILLER / HEAT PUMP. The high performance packaged solutions for all your needs

WATER CHILLER / HEAT PUMP. The high performance packaged solutions for all your needs WATER CHILLER / HEAT PUMP Aquaciat / Aquaciat Power The high performance packaged solutions for all your needs The Aquaciat Range: the versatile way to sustainable comfort Available in air-cooled chiller

More information

DRY COOLERS CERTIFY ALL DRY COOLERS

DRY COOLERS CERTIFY ALL DRY COOLERS DRY COOLERS CERTIFY ALL DRY COOLERS LU-VE S.p.A. - Uboldo (VA) Italy Heat exchangers for industrial and commercial refrigeration, air conditioning and industrial applications. LU-VE S.p.A. is the holding

More information

INVERTER ROOF TOP PACKAGE UNITS

INVERTER ROOF TOP PACKAGE UNITS INVERTER ROOF TOP PACKAGE UNITS SMART PACKAGE UNITS Delivering an extensive range, with capacities starting from 11kW up to 270kW, incorporating inverter technology throughout our roof top package units.

More information

Plug Fans with EC motor

Plug Fans with EC motor Plug Fans with EC motor version 05/2011 The engineer s choice New Plug fans with EC motor The plug fans of the centrifugal series with GreenTech EC technology, already established in the market, are now

More information

MIR COOLED INCUBATORS

MIR COOLED INCUBATORS MIR COOLED INCUBATORS Model Range: MIR Cooled Incubators PHCbi s Cooled Incubators have been recognised as exceptional units suitable for a wide range of applications. These incubators offer precise, repeatable

More information

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Model KMF 115 Constant climate chambers with expanded temperature / humidity range Model KMF 115 Constant climate chambers with expanded temperature / humidity range The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant

More information

Heat recovery units. One can live 3 weeks without food, 3 days without water, 3 minutes without air!

Heat recovery units. One can live 3 weeks without food, 3 days without water, 3 minutes without air! Heat recovery units The air we breathe is important for our life! One can live 3 weeks without food, 3 days without water, 3 minutes without air! People in industrialized countries spend indoor, on average

More information

Learn more about Samsung air conditioner at:

Learn more about Samsung air conditioner at: 2014 SAMSUNG New Ducted Air-Conditioner Learn more about Samsung air conditioner at: www.samsung.com/global/business/system-air-conditioner CONTENTS Smart Cooling - Global Top Efficiency - Powerful Cooling

More information

indoor air quality and energy saving TECHNICAL DATA JD/JD ENTHALPIC HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS

indoor air quality and energy saving TECHNICAL DATA JD/JD ENTHALPIC HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS indoor air quality and energy saving TECHNICAL DATA JD/JD ENTHALPIC HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS JD Remotable high efficiency heat recovery module without fans. To be interfaced

More information

CO2 solutions February 2018

CO2 solutions February 2018 CO2 solutions 27-28 February 2018 Summary Overview of regulations Overview of Rivacold solution CO2 carbon dioxide CO2 Rivacold solution Case History 2 1. Overview of regulations Overview of regulations

More information

madur GA21p-EN-v portable gas analyser

madur GA21p-EN-v portable gas analyser www..com portable gas analyser GA21plus is a portable analyser using advanced technologies. However, it remains s flagship due to its favorable price. It can be equipped with up to 9 electrochemical and

More information

SWIMMING POOL HEATING CLIMEXEL LISTEN TO THE SILENCE... APPRECIATE THE PERFORMANCE... S ERIES HEAT/COOL PUMPS. P ool & Spa Equipment

SWIMMING POOL HEATING CLIMEXEL LISTEN TO THE SILENCE... APPRECIATE THE PERFORMANCE... S ERIES HEAT/COOL PUMPS. P ool & Spa Equipment SWIMMING POOL HEATING CLIMEXEL LISTEN TO THE SILENCE... APPRECIATE THE PERFORMANCE... S ERIES PROCOPI S INDUSTRIAL STRENGTH Procopi, a leading French manufacturer of pool and spa equipment, has joined

More information

MCW 5-39 kw. Indoor monobloc unit. Water chillers and heat pumps MCW PLUS. Compact single circuit units. 242 galletti.

MCW 5-39 kw. Indoor monobloc unit. Water chillers and heat pumps MCW PLUS. Compact single circuit units. 242 galletti. Water chillers and heat pumps MCW Indoor monobloc unit MCW - 39 kw Compact single circuit units Rotary compressor PLUS Scroll compressor R-0C R-0 C refrigerant Cooling only Cooling / Heating Ease of installation

More information

FLEXY EC HIGH EFFICIENCY ROOFTOP kw AIR COOLED COOLING ONLY/HEAT PUMP/ GAS/ DUAL FUEL

FLEXY EC HIGH EFFICIENCY ROOFTOP kw AIR COOLED COOLING ONLY/HEAT PUMP/ GAS/ DUAL FUEL FLEXY EC HIGH EFFICIENCY ROOFTOP AIR COOLED COOLING ONLY/HEAT PUMP/ GAS/ DUAL FUEL 85-234 kw Energy savings through innovations Guaranteed sustainable performance with edrive With a rooftop, the major

More information

CONSTRUCTION REQUIREMENTS

CONSTRUCTION REQUIREMENTS CONSTRUCTION REQUIREMENTS Note: The buildings on the UCCS campus are divided into two categories: General Fund and Auxiliaries. General Fund Buildings include academic and administrative functions. Auxiliary

More information

Price Fan Powered Terminal Units

Price Fan Powered Terminal Units Price Fan Powered Terminal Units Division 23 Heating, Ventilating, and Air Conditioning Section 23 3600 Air Terminal Units The following specification is for a defined application. Price would be pleased

More information

WHISPER Enthalpy. Climaveneta Technical Bulletin. Packaged reversible Rooftop unit, air cooled, high efficiency with Enthalpic heat recovery

WHISPER Enthalpy. Climaveneta Technical Bulletin. Packaged reversible Rooftop unit, air cooled, high efficiency with Enthalpic heat recovery Climaveneta Technical Bulletin WHISPER_ENTHALPY_0102_0604_201203_EN r HFC R-410A 0102-0604 47-243 kw Packaged reversible Rooftop unit, air cooled, high efficiency with Enthalpic heat recovery (The photo

More information

indoor air quality and energy saving TECHNICAL DATA HRU-EC INVERTER HEAT RECOVERY VENTILATION UNITS with INTEGRATED AIR/AIR HEAT PUMP (CLIMATIZATION)

indoor air quality and energy saving TECHNICAL DATA HRU-EC INVERTER HEAT RECOVERY VENTILATION UNITS with INTEGRATED AIR/AIR HEAT PUMP (CLIMATIZATION) indoor air quality and energy saving TECHNICAL DATA HRU-EC INVERTER HEAT VENTILATI UNITS ith INTEGRATED AIR/AIR HEAT PUMP (CLIMATIZATI) HRU-EC HRU-EC is an active recovery unit for heating, cooling and

More information

Min Max Min Max m³/h l/sec m³/h l/sec Pa Pa C C

Min Max Min Max m³/h l/sec m³/h l/sec Pa Pa C C The product has a very small overall dimension making them ideal for installations in cramped areas. The units are enclosed to IPX4 protection rating, these fans are protected against jets of water from

More information

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast!

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast! MOBILE SUBSTATIONS TRAILER AND SKID tgood.com Energy, Fast! Global leader in E-House and prefabricated substation solutions PRODUCT OVERVIEW Custom configurable skid-mounted and trailer-mounted designs.

More information

Minimum Energy Consumption 84% energy heating savings*

Minimum Energy Consumption 84% energy heating savings* 3 HOUSE DESIGNS OF 140m² A modern concept for energy efficiency ENERGY EFFICIENCY AND ENVIRONMENTAL QUALITY Minimum Energy Consumption 84% energy heating savings* * According to a home fulfilling thermal

More information

lindab we simplify construction LindabAirMovement Product overview Fan Assortment

lindab we simplify construction LindabAirMovement Product overview Fan Assortment lindab we simplify construction LindabAirMovement Product overview Fan Assortment 2 We simplify construction At Lindab we are driven by a strong desire to continuously generate improvements and to simplify

More information

RS 6/C/ Published July RATING STANDARD for the CERTIFICATION of AIR HANDLING UNITS

RS 6/C/ Published July RATING STANDARD for the CERTIFICATION of AIR HANDLING UNITS RATING STANDARD for the CERTIFICATION of AIR HANDLING UNITS Supersedes RS 6/C/005-2017 Editing (date): Anthony BAILLAU (June 2018) Approval date: 20/07/2018 Comes into effect from: 26/07/2018 Modifications

More information

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics Condensers & dry coolers ODIN Excellent energy yield & sound characteristics O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................. 2 Eurovent.......................................

More information

Ecodesign FROM REGULATION 1253 & 1254/2014. For Residential And Non-Residential Ventilation Units

Ecodesign FROM REGULATION 1253 & 1254/2014. For Residential And Non-Residential Ventilation Units Ecodesign FROM REGULATION 1253 & 1254/2014 For Residential And Non-Residential Ventilation Units FULL FRESH AIR SYSTEMS Creating a better internal environment The Ecodesign Directive The Ecodesign Directive

More information

Price High Performance Horizontal Fan Coil Units

Price High Performance Horizontal Fan Coil Units Price High Performance Horizontal Fan Coil Units Division 23 Heating, Ventilating, and Air Conditioning Section 23 82 19 Fan Coil Units The following specification is for a defined application. Price would

More information

RETROFIT SOLUTIONS. For Gas Turbines And Rotating Machinery

RETROFIT SOLUTIONS. For Gas Turbines And Rotating Machinery RETROFIT SOLUTIONS For Gas Turbines And Rotating Machinery B E T T E R A I R I S O U R B U S I N E S S PERFORMANCE ENHANCING RETROFIT SOLUTIONS FOR GAS TURBINES AND ROTATING MACHINERY OUR AFTERMARKET QUALIFICATIONS

More information

AS950 ALL-WEATHER REFRIGERATED SAMPLER

AS950 ALL-WEATHER REFRIGERATED SAMPLER AS950 ALL-WEATHER REFRIGERATED SAMPLER Applications Wastewater Collection systems Industrial pretreatment Environmental monitoring Stormwater Sampling has never been this easy. Hach's AS950 sampler controller

More information

NV series. Induction VAV air volume control terminals

NV series. Induction VAV air volume control terminals NV series Induction VAV Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 overview / dimensions 4-5 Sound data NVOAOOB 6-7

More information

ANK. ANK heat pump All the heat you want more efficiency more savings more well-being

ANK. ANK heat pump All the heat you want more efficiency more savings more well-being ANK Please fill out the requested information Aermec adheres to the EUROVENT Certification Programme: LCP/A/P/R The products concerned appear in the EUROVENT web site www. eurovent-certification. com ANK

More information

madur portable gas analyser

madur   portable gas analyser www..com portable gas analyser A further development from the tried and tested GA-12 hand-held analyser. GA-12plus can be equipped with up to 4 electrochemical cells. By default fitted with Li-ion battery.

More information

Unit Coolers SKB. 4 kw 30,5 kw.

Unit Coolers SKB. 4 kw 30,5 kw. Unit Coolers SKB 4 kw 30,5 kw www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kw. NOMENCLATURE...

More information

Central Station Air Handler Specification

Central Station Air Handler Specification Central Station Air Handler Specification PART 1: GENERAL 1.01 WORK INCLUDED (Model CS 3 ) Mechanical Specification A. Provide complete air handling unit(s) suitable for indoor installation. Contractor

More information

SMART BUILDINGS. Always the best climate for. Zehnder ComfoAir Q ventilation units

SMART BUILDINGS. Always the best climate for. Zehnder ComfoAir Q ventilation units Decorative radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Always the best climate for SMART BUILDINGS Zehnder ComfoAir Q ventilation units SIMPLE PLANNING

More information

MODULE #5 MECHANICAL, ELECTRICAL, PLUMBING II

MODULE #5 MECHANICAL, ELECTRICAL, PLUMBING II MODULE #5 MECHANICAL, ELECTRICAL, PLUMBING II MICHAEL WALSH PRINCIPAL, R.G. VANDERWEIL ENGINEERS, LLP 274 Summer Street, Boston, MA 02210 (T) 617-423-7423 (F) 617-423-7401 mwalsh@vanderweil.com Module

More information

Air-Cooled Screw Chillers RTAF-G kw. The best bundled in one. Our best.

Air-Cooled Screw Chillers RTAF-G kw. The best bundled in one. Our best. Air-Cooled Screw Chillers RTAF-G 320 1720 kw The best bundled in one. Our best. 1 The Future of F-Gases The fluorinated refrigerants phase-down, as defined in the new EU F-Gas Regulation, is a step-by-step

More information

LG Renewable Heating Solutions

LG Renewable Heating Solutions RENEWABLE > SHIFT AWAY FROM FOSSIL FUELS LG Renewable Heating Solutions Products in this brochure contain fluorinated greenhouse gases (R410A) and (R134a) LG Air Conditioning and Energy Solutions UK Energy

More information

Anyvib Vibration Test Chambers

Anyvib Vibration Test Chambers Anyvib Vibration Test Chambers WHY ANYVIB? Because anyvib is the easiest way to combine any kind of shaker with an environmental test chamber. anyvib is a new family of climatic chambers that can be interfaced

More information

When you need more than just Ventilation!

When you need more than just Ventilation! When you need more than just Ventilation! BENEFITS OF ENERGY RECOVERY: INDOOR AIR QUALITY The Indoor Air Quality (IAQ) of a building can have broad, potentially harmful, implications for occupants that

More information

MULTI SPLIT INVERTER SYSTEMS

MULTI SPLIT INVERTER SYSTEMS MULTI SPLIT INVERTER SYSTEMS Energy Saving For conventional air-conditioning unit, the compressor will be running at the maximum frequency all the time. This requires a lot of energy and subsequently,

More information

Aeronex Gas Purification System HX Series

Aeronex Gas Purification System HX Series MICROCONTAMINATION CONTROL Aeronex Gas Purification System HX Series Continuous high-flow, ultrapure process and carrier gases at a low cost of ownership Advanced Technology in High-flow Gas Purification

More information

madur portable gas analyser

madur   portable gas analyser www..com portable gas analyser A further development from the tried and tested GA-12 hand-held analyser. GA-12plus can be equipped with up to 4 electrochemical cells. By default fitted with Li-ion battery.

More information

RS 6/C/ Published December RATING STANDARD for the CERTIFICATION of AIR HANDLING UNITS

RS 6/C/ Published December RATING STANDARD for the CERTIFICATION of AIR HANDLING UNITS RATING STANDARD for the CERTIFICATION of AIR HANDLING UNITS Supersedes RS 6/C/005-2016 Editing (date): Anthony BAILLAU (September 2016) Checking (date): Jean FOURCROY (8 November 2016) Approval (date):

More information

UBC Technical Guidelines Section Edition Fume Hoods Page 1 of 5

UBC Technical Guidelines Section Edition Fume Hoods Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 12 35 53 Laboratory Casework.2 Section 23 38 16 Fume Hood Exhaust Systems.3 Section 20 00 08 Mechanical Identification for the details for fume

More information

Gas Generator ULTRA HIGH PURE - HIGH FLOW. Gas Generator

Gas Generator ULTRA HIGH PURE - HIGH FLOW. Gas Generator Gas Generator ULTRA HIGH PURE - HIGH FLOW Gas Generator Zero Air Generator for GC Zero Air Generator produces a continuous flow of high purity Zero Air at selected pressure. The modular pressure swing

More information

KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions

KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions Plant growth chambers KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect

More information

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump MIRAI SMI Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump Air conditioning Technical sheet 20C GB02 Indice Monobloc heat pump

More information

Product catalogue A25s. Solar Cooling systems

Product catalogue A25s. Solar Cooling systems Product catalogue A25s Solar Cooling systems COOLING POWERED BY NATURE FLEXIBLE DESIGN The Purix Solar Cooling system helps you building a green tomorrow without compromising the basic needs for a comfortable

More information

VRF V4+K Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group

VRF V4+K Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group Coercial Air Conditioners 2016 Coercial Air Conditioner Division Midea Group VRF V4+K Series 50Hz Midea CAC After-service Application Midea CAC News Application Add.: West Region of Midea Coercial Air

More information