REFERENCE MEASURING INSTRUMENT

Size: px
Start display at page:

Download "REFERENCE MEASURING INSTRUMENT"

Transcription

1 testo 350 M/XL, flue gas measuring system TECHRENTAL NOTE: Pages selected from Testo catalogue Options not included with TR assets are removed or "greyed-out" mith Ltd. Cont. switch-off function PC analysis Data communication via PC, barcode pen printer Prints readings on site 4 user defined function buttons Burner 5/ C % H % Ptop Zoom Gas dp = 0 Milltown Location: Burner /06 Robust housing with impact protection Print Large memory testo 350 is a flexible, portable measuring system for a broad range of combustion applications. This advanced analyser can be used to adjust all types of industrial burners measure concentrations in raw and clean gas over a longer time period check the atmospheres of all types of process furnaces maintain stationary motors such as modular cogeneration stations check gas pressures and gas velocities in flue gas and/or fresh air ducts. V Testo data bus User defined probe socket Connection for flue gas probe + additional temperature probe Robust universal plug for flue gas and differential pressure connection differential pressure/velocity Peltier gas preparation unit testo 350 M testo 350 XL Particle filter differential pressure probe The testo 350 M basic version includes control unit, analysis box and a flue gas probe. O2,, NO (optional, NO2, O2 (optional or 2 are measured via the infrared mesurement module (optional(max.4 measuring modules. Temperature and differential pressure, as well as the usual calculated variables 2 etc. are also measured. The detachable control unit can also be used as a separate analyser for temperature, velocity, differential pressure, relative humidity etc. The readings can be printed on the integrated printer. A complete Peltier gas preparation unit for controlled condensate removal is also built into the analysis box. The more advanced testo 350 XL includes, in addition to the M version, NO and NO2 parameters, an event trigger socket, a fresh air valve as well as the option of upgrading an additional 2 measuring modules. The, H2, O2 or 2 measuring modules are available in the XL version. Additional advantages at a glance Battery operation, also with gas preparation unit (up to 2-3 h with data memory function, also without control unit Easy and fast operation via touchscreen (optional Measuring range extension (optional for uitable flue gas probe available for every application Extremely high accuracies for low NOx and thanks to special gas sensors Easy handling due to low weight (approx. 4.5 kg and compact size Can withstand tough conditions thanks to N m

2 272 testo 350 M/XL, Portable flue gas analyser testo 350 M/XL C NO/N The portable concept An analyser must be easy to transport and robust to make it suitable for portable applications in industrial systems. A common desire is to have a remote display at the burner controls. For your advantage, the control unit in testo 350 M/XL is detachable and can be operated at up to 50 m away from the analysis box. Gas conditioning for industrial applications is needed whether you are carrying out a spot check or long-term s lasting for several hours. Testo s integrated gas conditioning system achieves accurate s of NOx or O2 and the analyser is also protected from corrosive condensate from the flue gas. Fast, easy inexpensive maintenance is assured! The user can exchange consumables such as measuring cells on site. Testo has a worldwide spare parts delivery service., %RH ΔP, Pa The control unit can operate the entire system and read out data or be used as a stand alone hand-held instrument. It alone can measure differential pressure, temperature, humidity, velocity etc. Additional benefits: PC interface (R232 to read out data Backlit graphic display User-friendly, menu guided operation with user defined function buttons data memory (1 MB Printout of current or saved data Touchscreen operation (option for quick operation and input Magnets on the rear for positioning on location Robust housing with impact protection Power supply via analysis box, replaceable battery or mains unit, C (IAQ,, NO X, O,... ΔP, Pa The analysis box is the heart of the analyser. The following is inside the housing: Respective gas sensors and differential pressure ample gas pump Peltier gas preparation unit (with hose pump for disposing of condensate switch/off (rinse function to protect the sensor Rechargeable NiMH battery (without memory effect Built-in mains unit (110/230 V, 50 to 60Hz Data memory (1MB Options such as fresh air valve (for longterm s with testo 350 M, XL included Can be used for portable operation in the following 3 positions: Vertical position (e.g. lying in case Edgewise (as data logger in connection with wall holder Hanging down from carrying handle

3 276 Gas sampling probes C ampling probes have to endure extreme conditions when measuring flue gases for example: High temperatures Corrosive condensate Dust Mechanical loads. The selection of the right probe is critical for accurate and consistent s. Because the sampling locations are often different, it s beneficial to have a standard probe designed for a wide variety of applications. In addition to the standard sampling probes, Testo also offers probe systems for specific industrial applications. tandard sampling probes NO/N The standard sampling probe is available in lengths of 335 mm and 700 mm and for different temperature ranges. The outer pipe with a sintered filter is used for dusty flue gases. The hose has a standard length of 2.2 m (5 m optional. 335/700 mm long Ø 8 mm T max 500/1000 Material: probe pipe T max +500 : tainless steel Material: probe pipe T max : tainless steel Option: Outer pipe with filter for dusty flue gases Hose length: tandard 2.2 m / 5 m optional 335/700 mm long Ø 8 mm Pore size: 3 μm / Material of probe pipe: tainless steel Ø 10 mm T max 800 tandard probe: 335 mm long tandard probe: 700 mm long Basic sampling probe: 335 mm long, T max Basic sampling probe: 700 mm long, T max Options Options Higher flue gas temperature/dusty flue gases: Higher flue gas temperature/dusty flue gases: Outer pipe with filter for dusty flue gases, Tmax or Outer pipe for high flue gas temperature, Tmax Hose: Hose length 5 m (not for O2 s pecial hose for O2 s 1, 2.2 m long pecial hose for O2 s 1, 5 m long Use outer pipe with filter for dusty flue gases. Outer pipe with filter for dusty flue gases, Tmax or Outer pipe for high flue gas temperature, Tmax Hose: Hose length: 5 m (not for O2 s pecial hose for O2 s 1, 2.2 m long pecial hose for O2 s 1, 5 m long

4 278 Measurement system and practical accessories Logger, measures and saves (max. 250,000 readings Options for NO2, O2,..., can also be upgraded on site at a later time 2 module, 0 to 50 vol.%, infrared principle, absolute pressure, 2 absorption filter with refill pack Protective cover for analysis box Wall holder for analysis box, incl. heat protection plate C NO/N Touchscreen with pen Ordering data: Measurement system and accessories testo 350, control unit displays data and controls the measuring system, incl. built-in printer, pressure 80/200, 1 user defined probe socket, programmable s and memory space for 250,000 readings, connection for Testo data bus, incl. terminal plug Touch screen with pen (available only with original order For easy input of text and values pare thermal paper for printer (6 rolls Barcode pen to read in locations Quick and accurate allocation of reading to site Barcode labels, self-adhesive (1200 off Location marked with barcode, printed using software Adhesive pockets (50 off for printout, paper barcode labels... IRDA interface, from control unit to PC For direct online transfer of readings to PC Analog output box ( out Testo rechargeable battery pack NiMH for control unit, logger Mains unit 230 V/ 8 V/ 1 A, for instrument (European plug Transport case ystem case (aluminium, incl. drawer Additional box for system case , can be snapped on Ordering data: Measurement system and accessories testo 350 XL analysis box and equipment testo 350 XL analysis box, equipped with O2, (with switch-off and rinse function, NO, NO2, differential pressure, 2 temperature probe sockets, gas preparation, Testo data bus connection, automatic fresh air rinse with valve, integrated rechargeable battery, data memory, can be upgraded to max. 6 modules (With H2,, O2 low module, 0 to 500, highly accurate, instead of standard module, built into analysis box 2 module, 0 to 50 vol.%, infrared principle, absolute pressure, 2 absorption filter with refill pack NOlow module, 0 to 300, highly accurate, instead of standard NO module, built into analysis box O2 module, built into analysis box module (nonburned hydrocarbons, built into analysis box H2 module, built into analysis box Measuring range extension for module (dilution, built into analysis box, selectable dilution factors: 0, 2, 5, 10, 20, 40 Event trigger socket, for starting and stopping externally, built into analysis box testo 350 M analysis box and equipment testo 350 M analysis box, with O2, (with switch-off and rinse functions, gas preparation, diff. pressure meas., 2 temperature probe sockets, can be upgraded to max. 4 modules (with NO/NO2/O2, Testo data bus connection, built-in rech. batt., data memory low module, 0 to 500, highly accurate, instead of standard module, built into analysis box module, 0 to 50 vol.%, infrared principle, absolute pressure, 2 absorption filter with refill pack NO measuring module, 0 to 3000, built into analysis box NOlow module, 0 to 300, highly accurate, built into analysis box NO2 measuring module, built into analysis box O2 module, built into analysis box Fresh air valve for long-term, built into analysis box Measuring range extension for module (dilution, built into analysis box, selectable dilution factors: 0, 2, 5, 10, 20, Accessories for analysis boxes Wall holder for analysis box incl. heat protection plate, can be locked Protective cover for analysis box (can also be used with wall holder Carrying belt set for analysis box and control unit Transport case for analyser, probes and accessories ystem case (aluminium, with drawer for accessories, for transport and protection during Additional box for system case , can be snapped on IO calibration certificate/flue gas Calculation of fuel-specific factors to accurately display calculated variables in deviating fuels (calculation for one fuel pare particle filter, pack of 20 Hose set to convey flue gas from analysis box, 5 m long Refill pack of filter pellets for 2 absorption filter

5 Technical data Technical data/testo 350 M analysis box, testo 350 XL Temperature (H2 compensated low meas. (H2 compensated C NO meas. (option for testo 350 M NOlow NO2 measuring module (option for testo 350 M O2 Meas. range -40 to to to to to C max Vol. % C 0 to NO 0 to +300 NO 0 to +500 N 0 to ±0.5% of mv (+100 to ±0.5 (-40 to ±0.8% of f.v. +25 ±5% of mv (+200 to ±10% of mv (+2001 to ± ±5% of mv (+40 to +500 ± Calculated from to NO ±10% of mv (+2000 to NO ±5 NO +99 NO ±5% of mv (+40 to +300 NO ±2 NO NO to +500 N ±5 N N to ±10% of mv (+2001 to ±5 +99 Resolution 0.1 (-40 to (0 to C 1 NO NO 0.1 NO +300 NO 0.1 N +500 N Reaction time 20 s 40 s 40 s 20 s 40 s V Reaction type t 95 t 95 Efficiency Flue gas loss Differential pressure 1 Differential pressure 2 Velocity C (IR Meas. range 0 to +120 % -20 to % -200 to to to to 50 C ±1.5% of mv (-50 to -200 ±1.5% of mv (+50 to +200 ±0.5 (-49.9 to ±1.5% of mv (-40 to -3 ±1.5% of mv (+3 to +40 ±0.03 (-2.99 to ±0.3 C + 1% of mv 25 C ±0.5 C + 1.5% of mv (>25 to 50 C N Resolution 0.1 % +120 % 0.1 % (-20 to % 0.1 (-200 to (-40 to C 25 C 0.1 C (>25 C Reaction time <10 s Reaction type Dimensions 395 x 275 x 95 mm Weight 3200 g torage temp. -20 to +50 Oper. temp. -5 to +45 Material/Housing AB Additional technical data: Memory: readings Power supply: Via integrated mains unit (90 V to 260 V, 47 to 63 Hz or exchangeable rechargeable batteries Electrical power required: 0.5 A (110 V AC, 0.3 A (230 V AC Dew point calculation: 0 to 99 td Maximum positive pressure of flue gas: 50 (500 mm water column Maximum negative pressure: 200 (2000 mm water column Pump flow: 0.8 with flow monitoring Max. dust load: 20 g/m³ dust in flue gas Max. humidity load: +70 Dew point temperature at analyser box inlet Measuring range extension (dilution for : dilution factors 0, 2, 5, 10, 20, 40 Dilution gas: Fresh air or N2 : Reading plus max. 2% Trigger input testo 350XL: Voltage: 5 to 12 volt (rising or falling edge Pulse width > 1 second Load: 5 V/max. 5, 12 V/max. 40 Warranty: Analysers: 2 years (excluding working parts e.g. measuring cells... /NO/NO2/O2/H2//2 sensor: 1 year O2 measuring cell: 1.5 years Additional technical data for testo 350 XL analysis box only Meas. range Additional technical data: Trigger input: 5 to 12 V (rising or falling edge H2 0 to +300 ±5% of mv (+40 to +300 ± Resolution Reaction time 35 s Reaction type Technical data for module Parameter Measurement range 100 to 40,000 Resolution Min. 02 requirement in flue gas Methane less than 400 (100 to 4000 less than 10 % of m.v. (greater than % + (2 x methane reading Reaction time t90 less than 40 s Response factor * 1 Propane 100 to 21,000 less than 400 (100 to 4000 less than 10 % of m.v. (greater than % + (5 x propane reading less than 40 s 1.5 Butane 100 to 18,000 less than 400 (100 to 4000 less than 10 % of m.v. (greater than % + (6.5 x butane reading less than 40 s 2 ¹ Lower explosion limit must be adhered to. ² The module is adjusted to methane in the factory. It can be adjusted to another gas by the user. m

Compact flue gas analyser: testo 300 M-I

Compact flue gas analyser: testo 300 M-I 220 Compact flue gas analyser: testo 300 M-I PC analysis Prints Small memory -------------------- testo 300-I -------------------- 16.07.2001 09:36:22 C Quick flue gas checks are of interest for all industrial

More information

testo 350 M testo 350 XL

testo 350 M testo 350 XL Complex thermal applications - Easy measurements! Portable, modular flue gas analyser for industrial processes testo 350 M testo 350 XL Easily upgraded with additional analysis boxes for more measurement

More information

testo 330 Flue gas analysis with increased convenience and safety

testo 330 Flue gas analysis with increased convenience and safety 10 testo 330 Flue gas analysis with increased convenience and safety How many degrees is it really? How sure can you really be that your analyser measures exactly what it should be measuring? Our certified

More information

New Measurement Engineering For Monitoring Emissions In Industry

New Measurement Engineering For Monitoring Emissions In Industry testo 335 New Measurement Engineering For Monitoring Emissions In Industry Increased efficiency and convenience NEW! C O 2 CO/H 2 CO low /H 2 NO NO low NO 2 SO 2 hpa m 3 /s kg/h qa λ The new analyser generation

More information

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters Committing to the future testo 327-1/-2 The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters NEW! O 2 CO 2 C hpa CO O 2 EN 50379-2 and 1. BImSchV TÜV-tested for O 2, C, hpa The

More information

Fine particle measuring system

Fine particle measuring system Data sheet testo 380 Fine particle measuring system testo 380 The innovative complete solution In combination with testo 330-2 LL, the innovative complete solution for solid fuels, oil and gas systems.

More information

testo 340 Speed, power & precision in industrial combustion analysis.

testo 340 Speed, power & precision in industrial combustion analysis. testo 340 Speed, power & precision in industrial combustion analysis. testo 340 The testo 340 Portable Combustion Analyzer Speed, power & precision in combustion analysis. Optimizing the combustion process

More information

Humidity/temperature measuring instrument

Humidity/temperature measuring instrument Humidity/temperature measuring instrument testo 645 Highly precise measurements for industry Highly accurate humidity measurement up to ±1 %RH %RH Connection of 2 plug-in probes Measurement of temperature,

More information

Flue gas analyzer. We measure it. testo 310 Flue gas analysis the easy way. Robust design for daily use. Battery lifetime up to 10 hours

Flue gas analyzer. We measure it. testo 310 Flue gas analysis the easy way. Robust design for daily use. Battery lifetime up to 10 hours Flue gas analyzer testo 310 Flue gas analysis the easy way Robust design for daily use Battery lifetime up to 10 hours Integrated menus: Flue gas, draught, ambient CO and pressure Fast sensor zeroing in

More information

Flue gas analysis brilliantly easy: testo 350

Flue gas analysis brilliantly easy: testo 350 We measure it. analysis brilliantly easy: testo 350 the first flue gas analyzer that thinks ahead testo 350 We measure it. The new flue gas analyzer testo 350 offers advantages and real benefits as you

More information

Flue gas analyser. We measure it. testo 327 The special class entry instrument. Simple menu structure

Flue gas analyser. We measure it. testo 327 The special class entry instrument.  Simple menu structure Flue gas analyser testo 327 The special class entry instrument O 2 Simple menu structure 4-line segment display with LED illumination Fast, single-plug probe connection CO 2 CO 8 selectable fuels Life

More information

Multi-function VAC measuring instrument

Multi-function VAC measuring instrument Data sheet testo 480 Multi-function VAC measuring instrument testo 480 Cutting-edge technology for professionals Measurement of all VAC-relevant parameters: flow velocity, temperature, humidity, pressure,

More information

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas MRU over 30 years of innovative gas analysis! Biogas analysers Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas Product overview MRU Biogas analysers Whether biogas, landfill and coal mine

More information

Multifunction HVAC and IAQ Meter

Multifunction HVAC and IAQ Meter 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 435 Multifunction HVAC and IAQ Meter NEW! The newest technology for temperature,

More information

GAS 3050P NDIR FLUE GAS

GAS 3050P NDIR FLUE GAS Portable gas analyser GAS 3050P NDIR FLUE GAS Industrial flue gas analysis Powerful, robust and transportable on any industrial site, the GAS 3050P NDIR FLUE GAS analyser offers the same performances as

More information

Instruction Manual Dräger MSI EM200-s

Instruction Manual Dräger MSI EM200-s Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 950; Edition 2011-01-01 Content 1. Reference notes Page 3 1.1 Approvals 1.2 Information

More information

Online Gas Analyzer / Monitor

Online Gas Analyzer / Monitor Sheet No. 1 of 9 CH4 H2 SOX NOX NH3 CO2 HF HCL HCN CO O2 Providing the latest in Combustion Gas & Emission Analyzers for Boiler, Engine, Furnace, and other applications. Sheet No. 2 of 9 Vasthi OMGA 8000

More information

Flue gas analyzer. We measure it. testo 327 The special class entry instrument. Simple menu structure. 4-line segment display with LED illumination

Flue gas analyzer. We measure it. testo 327 The special class entry instrument. Simple menu structure. 4-line segment display with LED illumination We measure it. Flue gas analyzer testo 327 The special class entry instrument Simple menu structure O 2 4-line segment display with LED illumination Fast, single-plug probe connection 8 selectable fuels

More information

Measuring Instruments for Flue Gas and Emissions

Measuring Instruments for Flue Gas and Emissions Committing to the future 2011 Measuring Instruments for Flue Gas and Emissions CO NO SO 2 Vol. % O 2 C hpa rpm V ma HC Information Flue gas analysis Ideal operating range of burners Flue gas loss (qa)

More information

The new testo 330 LL visualizes measurement data graphically

The new testo 330 LL visualizes measurement data graphically Committing to the future NEW: testo 330 LL The new testo 330 LL visualizes measurement data graphically Understand flue gas analysis at a glance C hpa O 2 12.01.10 14:35 CO/H 2 testo AG Flue gas NO ΔP

More information

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version COMBIMASS Technical Data / GA-e Version 2013-05 _- PORTABLE GAS ANALYZER COMBIMASS GA-m/ GA-e For decades now, Binder has been supplying leading plant manufacturers with innovative systems for industrial

More information

GreenLine 8000 GAS ANALYSIS. Portable Industrial Combustion & Emission Analyser O 2 CO 2 CO CO% SO 2 CH X Y NO 2 HS 2

GreenLine 8000 GAS ANALYSIS. Portable Industrial Combustion & Emission Analyser O 2 CO 2 CO CO% SO 2 CH X Y NO 2 HS 2 Eurotron Instruments ISO 9001 Q u a li ty n Gra d e t eurotron "Excellence in measurements" Portable Industrial Combustion & Emission Analyser The most powerful and advanced unit with built-in cooling

More information

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month WEATHER MONITORING ELE Weather Sensors 411 E 215 pw 646 pm Wide ranging expandable air monitoring system, particularly suitable for ambient air analysis Includes sensors for: Wind speed Wind direction

More information

EUROλYZER STx. Flue Gas Analyzer. BlueLine

EUROλYZER STx. Flue Gas Analyzer. BlueLine EUROλYZER STx Flue Gas Analyzer BlueLine The flue gas analyzer for measurement of small and medium-sized oil, gas and pellet heating systems in accordance with the German Federal Immision Act and to verify

More information

Combustion Laboratory Unit C492

Combustion Laboratory Unit C492 Combustion Laboratory Unit C492 Figure 1: C492 Unit with Optional C492A fitted Purpose built Combustion Chamber, with Instrumentation Designed for Supervised Student Operation Oil or Gas Burners Available

More information

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS PORTABLE FLUE GAS MONITORING WWW.LANCOM4.COM i CO low CO high O 2 NO NO2 NOx CO2 H2S SO2 CxHy QUALITY CUSTOMER SOLUTIONS AMETEK LAND HAS BEEN MANUFACTURING PRECISION MEASURING EQUIPMENT SINCE 1947. WE

More information

testo 350 M/XL Short Operation Instruction Manual Rev. 11/03 Instrument Software Version 1.30

testo 350 M/XL Short Operation Instruction Manual Rev. 11/03 Instrument Software Version 1.30 testo 350 M/XL Short Operation Instruction Manual Rev. 11/03 Instrument Software Version 1.30 800-227-0729 www.testo.com testo inc. 35 Ironia Rd. Flanders, NJ 07836 Fax: 973-252-1729, e-mail: info@testo.com

More information

Designed to meet BS7927, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389

Designed to meet BS7927, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389 A unit of E instruments Group LLC Portable Industrial Combustion & Emission Analyzer The most powerful and advanced unit with built-in gas cooler and heater for sampling hose & probe Up to 8 sensors temperature

More information

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Online data sheet MCS100E HW-C CEMS SOLUTIONS Online data sheet MCS100E HW-C A B C D E F H I J K L M N O P Q R S T Ordering information Type MCS100E HW-C Part no. On request The exact device specifications and performance data of the product may deviate

More information

Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification.

Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification. Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification. testo NanoMet3 The portable solid particle counter testo NanoMet3. Measure in real environmental situations. Onboard

More information

Tintometer -Group. MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit

Tintometer -Group. MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit Tintometer -Group MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit ph ORP/Redox Conductivity TDS Salinity Temperature 110 Regularly updated information: www.tintometer.com

More information

Using the PPM2 Portable Trace Moisture Transmitter

Using the PPM2 Portable Trace Moisture Transmitter APPLICATION NOTE 2016_0106 PPM2 Using the PPM2 Portable Transmitter The Model PPM2 Portable analyzer is a compact, cost effective, analyzer specifically designed to continuously measure low levels of moisture

More information

GreenLine 6000 GreenLine 8000

GreenLine 6000 GreenLine 8000 Specifications Hand-Held Remote Control Unit MCU-RCU Communication: - Bidirectional RS3 Cable - Bluetooth wireless Integrated Printer: Impact type 4 columns with.3 wide and 59 ft long paper roll. Power

More information

Online data sheet SMC209 C CEMS SOLUTIONS

Online data sheet SMC209 C CEMS SOLUTIONS Online data sheet SMC209 C A B C D E F H I J K L M N O P Q R S T Ordering information Type SMC209 C Part no. On request The exact device specifications and performance data of the product may deviate from

More information

testo 330-1, -2, -3 Flue gas analyser Instruction manual

testo 330-1, -2, -3 Flue gas analyser Instruction manual Instruction manual GasTech Australia Pty Ltd 24 Baretta Rd Wangara Western Australia 6065 Tel 1800 999 902 Fax 1800 999 903 http://www.gastech.com.au testo 330-1, -2, -3 Flue gas analyser en 2 General

More information

testo 310 Flue gas analyzer Instruction manual

testo 310 Flue gas analyzer Instruction manual testo 310 Flue gas analyzer Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 5 2.1. About this document... 5 2.2. Ensure safety... 6 2.3. Protecting the environment...

More information

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control Sampling Stationary Portable Sampling is an important factor for the compliance with required regulations and efficient operation. It forms the basis for continuous monitoring objectives and criteria,

More information

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications Dekati ELPI Electrical Low Pressure Impactor Real-time particle size distribution Wide particle size range Wide range of applications Excellence in Particle Measurements Dekati ELPI Electrical Low Pressure

More information

Instruction manual. testo 330-1, -2, -3 / testo 330-1, -2 Flue gas analyser

Instruction manual. testo 330-1, -2, -3 / testo 330-1, -2 Flue gas analyser Instruction manual testo 330-1, -2, -3 / testo 330-1, -2 Flue gas analyser en 2 General notes General notes Please read this documentation through carefully and familiarise yourself with the operation

More information

ph & TDS instrumentation 2017 specialists in temperature measuring equipment for over 30 years

ph & TDS instrumentation 2017 specialists in temperature measuring equipment for over 30 years ph & TDS instrumentation 2017 specialists in temperature measuring equipment for over 30 years ph instrumentation analytical ph Pal Plus ph Tester ideal for food processing & laboratories pocket-sized

More information

OPUS20 LAN-Datalogger Future Inside

OPUS20 LAN-Datalogger Future Inside OPUS20 LAN-Datalogger Future Inside a pa ssio n fo r pr ecis ion pa ssion po ur la préc is ion pasi sión por la pr ec isió ió n pa ssio ne per la pr ecis isio ione a www.lufft.com The world s toughest

More information

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

TURBIDITY TB 300 IR TB 210 IR TB 250 WL.  General Catalogue April 2015 TURBIDITY 128 TB 300 IR TB 210 IR TB 250 WL www.lovibond.com General Catalogue April 2015 Turbidity measurement The term "turbidity is used to describe the cloudy or milky appearance of liquid or solid

More information

COMBIMASS Thermal Gas Flow

COMBIMASS Thermal Gas Flow COMBIMASS Thermal Gas Flow The COMBIMASS series enables gas flow measurement for various applications in all industry sectors. COMBIMASS works according to the principle of thermal dispersion and determines

More information

testo 350 Combustion & Emission Analyzer Instruction manual

testo 350 Combustion & Emission Analyzer Instruction manual testo 350 Combustion & Emission Analyzer Instruction manual 2 1 Contents 1 Contents...3 2 Safety and the environment...7 2.1. About this document...7 2.2. Ensure safety...8 2.3. Protecting the environment...9

More information

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement 3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series Simultaneous Particulate and Gas Concentration Measurement Evolutionary Dual-Analysis Design 3M EVM Series

More information

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection A BINDER FD series Avantgarde.Line heating oven is always used when fast drying and sterilization is required. Thanks to

More information

Model BF 260 Incubators Avantgarde.Line with forced convection

Model BF 260 Incubators Avantgarde.Line with forced convection Model BF 260 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly

More information

PORTABLE HARDNESS TESTING

PORTABLE HARDNESS TESTING Portable Hardness Tester IPX-300 Handheld dynamic metal hardness tester with hardness conversion and automatic position setting. Dynamic hardness testing: quick and reliable Impact device D integrated:

More information

MRU Instruments, Inc. Houston, Texas Tel.: (844) (Toll Free)

MRU Instruments, Inc. Houston, Texas Tel.: (844) (Toll Free) MRU Instruments, Inc. Houston, Texas 77044 Tel.: (844) 590-4678 (Toll Free) info@mru-instruments.com www.mru-instruments.com DIGITAL MANOMETER DM 9200 Digital Micro Processor Controlled Manometers with

More information

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive Silica Analyzer 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity Grab sample capability Low maintenance Automated Silica Measurement Dependable and Sensitive Silica Analyzer 2800S i

More information

testo 330i Flue gas measuring instrument

testo 330i Flue gas measuring instrument testo 330i Flue gas measuring instrument Instruction manual www.testo-international.com/330imanuals 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 5 3 Use... 5 4 Product description...

More information

Coating Thickness Meter Data Sheet / Instructions

Coating Thickness Meter Data Sheet / Instructions Paint Test Equipment Coating Thickness Meter Data Sheet / Instructions Coating Thickness Meter Information The Paint Test Equipment Coating Thickness Meter easily measures all coatings on metallic substrates

More information

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring TARGAS-1 Portable Photosynthesis System Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring TARGAS-1 Main Console CO 2 & H 2 O Gas Analysis The TARGAS-1 console is compact, lightweight

More information

For Safe and Delicious Water

For Safe and Delicious Water RESIDUAL CHLORINE ANALYZER 400G NON-REAGENT FREE CHLORINE ANALYZER FC400G 400G RESIDUAL CHLORINE ANALYZER FC400G NON-REAGENT FREE CHLORINE ANALYZER Bulletin 12F01A01-01E www.yokogawa.com/an/ For Safe and

More information

THE NEW RESIDENCE PRO

THE NEW RESIDENCE PRO RE SIDENCE PRO RIELLO INTRODUCES THE NEW RESIDENCE PRO HIGH EFFICIENCY - AFUE 95% Optimal comfort and minimum consumption for both heating and domestic hot water (DHW). Innovative condensing DHW plate

More information

HND-F. Hand-held Humidity Precision Measuring Unit % weight moisture % relative humidity. starting with ± 0.1%

HND-F. Hand-held Humidity Precision Measuring Unit % weight moisture % relative humidity. starting with ± 0.1% Hand-held Humidity Precision Measuring Unit measuring monitoring analysing HND-F OMeasuring O range: 4... 100% weight moisture 0... 100% relative humidity OMeasuring O accuracy starting with ± 0.1% O O

More information

TVOC Heated FID VE 7

TVOC Heated FID VE 7 Rack Mount/Table Top THC Analyzer TVOC Heated FID VE 7 The VE7 19"/5PU rack mount and table top heated emission analyzer for the continuous determination of the mass concentration of total gaseous organic

More information

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument Fits Your Application Intelligent Rugged Flexible Ergonomic Easy to use Multi-Gas Instrument Draeger: First in detection Since 1937, when we introduced our first detector tube, Dräger has been the world

More information

Technical System Catalogue Modular PDU (PSM)

Technical System Catalogue Modular PDU (PSM) Technical System Catalogue Modular PDU (PSM) Benefits of PSM busbars at a glance Modular configuration, flexibly extendible Redundant designs in busbars are supported Vertical mounting in the rack without

More information

testo 340 Flue gas analyser Instruction manual

testo 340 Flue gas analyser Instruction manual testo 340 Flue gas analyser Instruction manual en 2 General notes Please read this documentation through carefully and familiarise yourself with the operation of the product before putting it to use. Keep

More information

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT. PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT CEMS Solution CONTINUOUS, EXTRACTIVE FLUE GAS MONITORING On MCS100E HW, from sampling

More information

Data Logging Solutions from Lascar Electronics

Data Logging Solutions from Lascar Electronics Data Logging Solutions from Lascar Electronics EasyLog USB Simple, Low-Cost Data Logging In this range: Each standalone USB data logger fulfils a specific logging function including the monitoring of temperature,

More information

Model BF 720 Incubators Avantgarde.Line with forced convection

Model BF 720 Incubators Avantgarde.Line with forced convection Model BF 720 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly

More information

Instruction manual. testo 340 Flue gas analyser

Instruction manual. testo 340 Flue gas analyser Instruction manual testo 340 Flue gas analyser en 2 General notes Please read this documentation through carefully and familiarise yourself with the operation of the product before putting it to use. Keep

More information

KANE455. Flue Gas Analyser with direct CO 2 measurement. Stock No: July Kane International Ltd

KANE455. Flue Gas Analyser with direct CO 2 measurement. Stock No: July Kane International Ltd KANE455 Flue Gas Analyser with direct CO 2 measurement Stock No: 18859-8 July 2014 Kane International Ltd CONTENTS Page No: KANE455 Overview 4 ANALYSER LAYOUT & FEATURES 5-6 1. BATTERIES 7 2. BEFORE USING

More information

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation Isco EZ TOC Continuous on-line TOC/TC measurement using low-temperature oxidation Easy Programming High Efficiency UV Reactor Enhanced NDIR Detector Flexible Four-Motor Pump System Advanced Dual Calibration

More information

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability Thermoforming packaging machine R 145 with MULTIVAC Clean Design Maximum process reliability and cleanroom suitability MULTIVAC R 145 Clean Design Thermoforming packaging machine R 145 with MULTIVAC Clean

More information

Melt tension measurement (Haul-Off)

Melt tension measurement (Haul-Off) Göttfert Werkstoff-Prüfmaschinen GmbH Siemensstraße 2 74722 Buchen Email: info@goettfert.de Internet: http://www.goettfert.com WERKSTOFF-PRÜFMASCHINEN GMBH Melt tension measurement (Haul-Off) The Haul-Off

More information

testo 338 Density gauge Instruction manual

testo 338 Density gauge Instruction manual testo 338 Density gauge Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 5 2.1. About this document... 5 2.2. Ensure safety... 6 2.3. Protecting the environment...

More information

QINEO PULSE. The versatile welding machine for industry

QINEO PULSE. The versatile welding machine for industry QINEO PULSE The versatile welding machine for industry Some ideas set the trend for future times. PULSE 2 CLOOS: Your brand for innovative welding technology! Providing added value for our customers! This

More information

COATING THICKNESS MEASURING

COATING THICKNESS MEASURING LIST- MAGNETIK COATING THICKNESS MEASURING www.list-magnetik.de COATING THICKNESS MEASURING on metallic substrate magnetic induction measuring method Paint Zinc coating eddy current measuring method d2

More information

EBI 10 High Precision Wireless Data Loggers

EBI 10 High Precision Wireless Data Loggers 8 Validation Data Loggers EBI 10 High Precision Wireless Data Loggers EBI 10 High Precision Wireless Data Loggers The Perfect Solution for Your Applications To fit each of your specific processes, ebro

More information

PORTABLE COATING THICKNESS GAUGE

PORTABLE COATING THICKNESS GAUGE Coating Thickness Gauge IPX-201F Handheld coating thickness gauge with F-probe for steel substrates. Clear 4 digit segment LCD display Magnetic induction measuring principle Non-magnetic coating on ferrous

More information

The Ton-Tel Weighbridge

The Ton-Tel Weighbridge The Ton-Tel Weighbridge Plug-and-Weigh Technology Built to last in a tough environment Proven reliability, lower total cost of ownership. Digital Load Cell weight sensors sealed to IP68. Plug-and-Weigh

More information

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing Furnaces for Research and Laboratory Testing Drying Ashing Tempering Preheating Sintering Firing Annealing Muffle Furnaces KL 03/11 KL 15/12 T max 1100 C and 1200 C Universal muffle furnaces for many laboratory

More information

AS950 ALL-WEATHER REFRIGERATED SAMPLER

AS950 ALL-WEATHER REFRIGERATED SAMPLER AS950 ALL-WEATHER REFRIGERATED SAMPLER Applications Wastewater Collection systems Industrial pretreatment Environmental monitoring Stormwater Sampling has never been this easy. Hach's AS950 sampler controller

More information

Ultrasonic Load Monitoring

Ultrasonic Load Monitoring Ultrasonic Load Monitoring Who We Are One Company, Total Support, Complete Solutions Over many years, Hydratight has provided world-class bolted joint solutions and continues to set international standards

More information

Fpollutant-free zero air for analytical

Fpollutant-free zero air for analytical Ambient Air Quality Monitoring System AQMS-100 Zero Air Generator PI AQMS-100 provides ultra pure Fpollutant-free zero air for analytical purpose. Remote monitoring and configuration can also be achieved

More information

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory. Configuration: XPLORER with ARCHIE and GLS* // XPLORER-NS Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory. TE Instruments has developed the XPLORER-NS, a Total Nitrogen and

More information

Carbon / Sulfur Analyzers

Carbon / Sulfur Analyzers CS-800 CS-2000 Carbon / Sulfur Analyzers CS-800 CS-2000 Unique ELTRA Dual Furnace Technology CS-2000 Specialists for Elemental Analysis For more than 30 years ELTRA has been one of the leading manufacturers

More information

Product Data Sheet Metco Twin 150 Powder Feeder

Product Data Sheet Metco Twin 150 Powder Feeder Product Data Sheet Metco Twin 150 Powder Feeder A very versatile and accurate volumetric powder feeder that can e used as a stand-alone unit or integrated into a thermal spray, laser cladding or powder

More information

Blackbox for sensitive freight.

Blackbox for sensitive freight. Blackbox for sensitive freight. Data logger testo 184: Temperature monitoring and quality data documentation in the transport of foods and pharmaceutical goods. testo 184 Optimum temperatures for sensitive

More information

Instruction manual. testo 335 Flue gas analyser

Instruction manual. testo 335 Flue gas analyser Instruction manual testo 335 Flue gas analyser en 2 General notes General notes Please read this documentation through carefully and familiarise yourself with the operation of the product before putting

More information

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed BIOGAS measurement and analysis in continuous of methane, carbon dioxide, hydrogen sulphide, oxygen and hydrogen. BGA/INCA as INnovative Case Analyzer

More information

High Temperature Vacuum Tube Furnace GSL Operational Manual

High Temperature Vacuum Tube Furnace GSL Operational Manual High Temperature Vacuum Tube Furnace GSL-1100 Operational Manual MTI Corporation 860 South 19 th Street, Richmond, CA 94804, USA Tel: 510-525-3070 Fax: 510-525-4705 E-mail: info@mtixtl.com Web site: www.mtixtl.com

More information

FITOCLIMA WALK-IN STABILITY

FITOCLIMA WALK-IN STABILITY FITOCLIMA WALK-IN TEMPERATURE AND HUMIDITY CHAMBERS ICH, GMP, WHO, FDA COMPLIANT Common applications include: Pharmaceuticals Food and Beverages Cosmetics Veterinary Storage and Conservation Quality control

More information

AlgaeTorch. The handy measurement instrument for rapid deployment. Fast and simple algae monitoring

AlgaeTorch. The handy measurement instrument for rapid deployment.  Fast and simple algae monitoring www.bbe-moldaenke.de The handy instrument for rapid deployment Fast and simple algae monitoring Designed for all types of surface water: lakes, reservoirs, rivers and bathing water What does the offer?

More information

Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo.

Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo. Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo. Measuring solutions for the food sector Precious goods deserve the greatest care

More information

Reverse Osmosis Desalinators

Reverse Osmosis Desalinators Reverse Osmosis Desalinators H2O Series Framed and Modular Technical Specification Cathelco Seafresh, Marine House,Dunston Rd, Chesterfield, Derbyshire, England, S41 8NY Tel: +44 (0)1246 45790 Fax: +44

More information

Water Softener softliq:mc. Intended use. Function. Design

Water Softener softliq:mc. Intended use. Function. Design Subject to modifications TD2-BS000de_004 Edition May 2016 Intended use The water softener softliq:mc may only and exclusively be used for the softening and partial softening of cold drinking water. The

More information

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS IRRIGATION EQUIPMENT LTD. FERTILIZER T A N K S SERIES 6000 APPLICATIONS Designed specifically for fertigation in agriculture Simple, efficient and trouble free operation. Standard models apply fertilizer

More information

TWIN LASER PARTICLE COUNTER

TWIN LASER PARTICLE COUNTER SERIES 30 TWIN LASER PARTICLE COUNTER Online and inline options available. Complete range of test options. Automatic on-line continuous test facility. Variable time & test programmes. Remote operating

More information

INVENTION ON SAMPLING BY YUNEL

INVENTION ON SAMPLING BY YUNEL A NEW ERA IN SAMPLING INVENTION ON SAMPLING BY YUNEL NEW TECHNOLOGY ON SAMPLING SYSTEMS OVER CONVEYOR 'SAMPLING SYSTEM WITH SUPER SHOCK PRINCIPLE IS IN CHARGE OVER CONVEYOR BELTS IN A COAL MINE 2 In New

More information

FLUXUS F/G601 and F/G608

FLUXUS F/G601 and F/G608 Portable, quick and reliable FLUXUS F/G01 and F/G0 Portable ultrasonic clamp-on gas and liquid flow meters Accurate Flexible Quick Rugged Ergonomic When measuring matters FLUXUS F/G0X Mobile flow measurement

More information

Trust but verify: Ensure product quality at all stages of production

Trust but verify: Ensure product quality at all stages of production QUALITY Trust but verify: Ensure product quality at all stages of production TRUST BUT The tool of choice for manufacturing Quality Control and Assurance To prevent product failures and their costly consequences

More information

ACX Analyzer systems for emission monitoring, cement applications and process measurement

ACX Analyzer systems for emission monitoring, cement applications and process measurement Data sheet 10/23-8.80 EN Rev. 6 ACX Analyzer systems for emission monitoring, cement applications and process measurement Measurement made easy Applications: Emission monitoring using performance-tested

More information

Gas concentrations in the air

Gas concentrations in the air Content The importance of measuring the quality of room air 16.02 Digital carbon dioxide sensor FYAD 00 CO2B10 16.04 Carbon dioxide probe FYA 600 CO2 16.05 Carbon monoxide probe FYA 600 CO 16.06 Oxygen

More information

On-Line Carbon in Ash System at PPL Montour for Increasing Ash Sales

On-Line Carbon in Ash System at PPL Montour for Increasing Ash Sales 2013 World of Coal Ash (WOCA) Conference - April 22-25, 2013 in Lexington, KY http://www.flyash.info/ On-Line Carbon in Ash System at PPL Montour for Increasing Ash Sales Todd Melick 1, Larry LaBuz 2,

More information

Tool Management Powered by. Flexible Professional Sustainable

Tool Management Powered by. Flexible Professional Sustainable TM Tool Management Powered by Flexible Professional Sustainable INCREASED PERFORMANCE THANKS TO OPTIMISED ADMINISTRATION PROCESSES IN TOOL MANAGEMENT Guhring s TM 326, TM 426 and TM 526 tool dispensing

More information

It s simple. USB data logger testo 184. Easy temperature monitoring and uninterrupted quality documentation in the transportation of pharmaceuticals.

It s simple. USB data logger testo 184. Easy temperature monitoring and uninterrupted quality documentation in the transportation of pharmaceuticals. It s simple. USB data logger testo 184. Easy temperature monitoring and uninterrupted quality documentation in the transportation of pharmaceuticals. testo 184 Reliable monitoring of temperature, humidity

More information