WEIDMANN Electrical Technology. Presentation at. NETA Trade Show. March 15 th, 2016
|
|
- Myra York
- 6 years ago
- Views:
Transcription
1 WEIDMANN Electrical Technology Presentation at NETA Trade Show March 15 th, 2016 WEIDMANN DIAGNOSTIC SOLUTIONS INC. A Member of the WICOR Group ELECTRICAL TECHNOLOGY
2 WICOR WORLDWIDE Company Overview
3 INSULATION - Power Transformer Company overview
4 Insulation - Distribution Transformers Insulation Overview
5 DRAWING NUMBER: Core leg 3rd Winding Core - Jack Ring Allowance Steel Jack Ring A 60 HZ BIL EQUIVALENT BIL / HR INDUCED LEVEL PHASE-PHASE Top Yoke or Jack Pad TX Jack Ring Bottom Yoke or Core Clamp 1 HR ENHANCED LEVEL PHASE-PHASE DELTA CONN. LEVEL 1 HR ENHANCED WYE CONN. PHASE-GROUND CREATED CHECKED ENGR. BY CONTRACT NUMBER CONTRACT APPROVAL DATE 3/04/93 THIRD FIRST ANGLE PROJECTION TITLE CUSTOMER NAME SIZE SCALE St. Johnsbury, VT Insulaton Clearances for Non-Steep Front/Non-Switching Surge Designs DRAWING NUMBER MAT CUSTOMER REF NO. SH. REV 1 OF 1 Insulation Overview Insulation System Design & Optimization Analyze Actual Design Develop New Design Analyze New Design Define Clearances Define Insulation Layout SK3493WP1 Insulation Clearances for NSF and NBSL Designs Voltage < VOLTAGES & BIL BIL APPLIED SETTING VOLTAGES A B C,D,E,F A CLEARANCES B C C TX Rings D WITH STATIC RING E LV Winding F E D C C HV HV Winding Winding Phase 1 B Phase 2 C1 Note: 1. Both C and C1 Minimums must be maintained. 2. End Clearances are taken from insulated static plate. 3. When Static Plates LV COIL are not present, takehv COIL HV COIL HV COIL End Clearances from insulated conductor. PHASE 1 PHASE 2 SK3493WP1 1 B R e l e a s e 1. 0 SECTION VIEW PHASE-PHASE SECTION VIEW
6 Progressive Diagnostics End User Segment - Diagnostic Services Oil Testing What sets us apart from our competition ISO Accredits competency of a laboratory to perform tests to industry standards: IEEE, IEC, ASTM. Rigorous requirements on employee competence, mgmt systems, equipment calibrations, laboratory physical environment, verification standard testing. Assure customers that laboratories follow standard exactly. Annual audits by 3 rd party auditors Only testing laboratories in US to have accreditation
7 Progressive Diagnostics Diagnostic Solutions Service Centers <2007 Original Labs 2000: Sacramento, CA Houston, TX Calgary, AB Philadelphia, PA Indianapolis, IN 2005 Burlington, ON 2009 Montreal, QC Denver, CO St. Johnsbury, VT (R&D) 2010 N. Canton, OH Saltillo, Mexico Shanghai, China Waukesha, WI TBD Poland Brazil Middle East Hubs/Satellites
8 Progressive Diagnostics ENGINEERING SERVICES Yoke OEM and Utility Transformer Engineering Design and Specification Analysis Power system(grid) analysis Power electronics 2D & 3D Electromagnetic studies for AC and HVDC transformers, rectifiers, switchgear, surge arresters, etc. Failure analysis Fleet Assessment Condition Assessment Thermal upgrades Factory and field inspections Commissioning/Decommissioning Ba
9 Information Management EDUCATION, TRAINING, AND KNOWLEDGE TRANSFER Technical Conferences Annual Client Technical Conf. Power Transformers Insulation Transformer Fluid Diagnostics Substation Maintenance and Diagnostics Regional/Local Seminars Group Training Events Customized training Offer Continuing Education Credits and IEEE and NETA Accreditations
10 Monitoring MONITOR PORTFOLIO / InsuLogix - GROWING FAMILY FOR OPTIMUM PERFORMANCE MONITORING (OPM) Sensors and Monitors B - Bushing 2013 T Mi F - Smart Insulation Integrator Platform InsuLogix Q Integrator Software enameplate (T) 2014 Health Index (T,Mp) H HM Q Multigas and Moisture 2012 WEIDMANN 2015 OPM (T,Mi,F) 2016 D - Dielectric Strength
11 Insulation Overview Complimentary Products and Logistics Services Warehousing and Inventory Mgmnt\
12 Moisture in Insulation and Transformer Dryout
13 TOPICS 1. Effects of moisture in Insulation 2. Moisture Absorption and Removal 3. Transformer Dryout Theory 4. Side effects on Dryout Process
14 Paper and Water in Transformers KVA Weight of 5% Initial Moisture Rating KV Paper (kg) kg/kva Kilograms Liters 3, , , , , , , Ref. S.D. Meyers Typically 90% of the initial moisture content will be removed to achieved a dryness of 0.5% moisture content
15 DISTRIBUTION OF WATER IN INSULATION Oil
16 HIGH MOISTURE CONTENT IN INSULATION CAN CAUSE: Significant Reduction in Dielectric Strength Accelerated Aging of the Cellulose Bubble Formation and Dielectric Failure Partial discharges in the Insulation Dry Cellulose < 0.3% by weight & Oil < 10 ppm H 2 O
17 MOISTURE CONTENT VS KV BREAKDOWN VOLTAGE Source: FM Clark Engineering Guide Book on Electrical Insulation
18 MOISTURE IN SOLID INSULATION KV Breakdown Voltage U(kV) Moisture Content x = 1% x = 4% x = 6% x = 8% x = 10% Power Factor Power factor tan (%) Temperature ( C ) Temperature ( C ) Moisture Content x = 1% x = 4% x = 6% x = 8% x = 10%
19 MOISTURE ACCELERATES AGEING PROCESS Source: H.P.Moser - Transformerboard
20 Critical temperature for bubble evolution 190 Kobayashi rapid heating 170 Kobayashi slow heating Temperature Davydov Oommen gas free 90 Oommen gas saturated WCP % w/w Ref. Sparling, Brian; GE Energy,
21 Topics 1. Effects of moisture in Insulation 2. Moisture Absorption and Removal 3. Transformer Dryout Theory 4. Side effects on Dryout Process
22 WHY DOES CELLULOSE ABSORRB WATER CHEMICAL BACKGROUND Due to the high number of hydroxyl-groups is the cellulose molecule very hydroscopic; meaning, these groups attract water molecules (H 2 O). CH 2 OH HO O HO OH O HO CH 2 OH OH O CH 2 OH O HO OH n - 2 OH
23 HOW MUCH WATER IS ABSORBED (AFTER LONG EXPOSURE TO AMBIENT) The amount of absorbed water is mainly governed by the relative humidity of the environment. It is hardly influenced by the type of cellulose used. The (relative) amount of water is not (or only marginally) dependent on: The thickness of the board / paper The density of the board / paper Temperature Oil impregnation (without / with oil)
24 HOW MUCH WATER IS ABSORBED (AFTER LONG EXPOSURE TO AMBIENT) Water content [%] low density Moisture equilibrium of Transformerboard at 23 C and 50% rh conditioned not oil impregnated high density low density oil impregnated high density Thickness [mm]
25 HOW FAST IS WATER ABSORBED How fast water is absorbed is governed by: The thickness of the board / paper The density of the board / paper Temperature Oil impregnation (without / with oil) Circulation of the surrounding medium (air / oil)
26 HOW FAST IS WATER ABSORBED Influence of the thickness Transformerboard T IV Water absorption [%] mm 3 mm 5 mm 8 mm Time [days]
27 HOW FAST IS WATER ABSORBED W a te r a b so rp tio n [% ] g/cm³ Influence of the density Board thickness 3 mm 1.25 g/cm³ Time [days]
28 HOW FAST IS WATER ABSORBED Influence of the temperature Transformerboard T IV, 3 mm W a te r a b s o rp tio n [% ] C 10 C Time [days]
29 HOW FAST IS WATER ABSORBED Influence of the oil impregnation Transformerboard T IV, 3 mm W ater absorption [%] not oil impregnated oil impregnated Time [days]
30 HOW FAST CAN WATER BE REMOVED FROM TRANSFORMERBOARD The drying process is a diffusion process. The rate of drying is therefore governed by the same parameters: Temperature Pressure Material thickness Material density Oil impregnated (without / with)
31 Topics 1. Effects of moisture in Insulation 2. Moisture Absorption and Removal 3. Transformer Dryout Theory 4. Side effects on Dryout Process
32 VACUUMING WITHOUT APPLICATION OF HEAT Heat of Vaporization Energy required to change from Liquid phase to Vapor phase..< Vacuum Level Study indicates that Vacuuming without application of heat : - No further benefit if > 24 hours - free room temperature 4 torr - heat of vaporization would lower the temperature to a point where remaining water will freeze making extensive vacuuming pointless Temperature > Good Practice Application of Heat multiple times during the Dryout Process
33 Topics 1. Effects of moisture in Insulation 2. Moisture Absorption and Removal 3. Transformer Dryout Theory 4. Side effects on Dryout Process
34 SIDE EFFECTS OF DRYING PROCESS 1. Effects on DP
35 EXPERIMENT EFFECTS ON DP Thin high-density pressboard samples (1 mm) Oven temperature: 105, 120, 140 C Time: 14 days Hot air circulation vs. Vacuum DP measurements during drying.
36 EXPERIMENT RESULT: Transformerboard T IV 1 mm Drying in air Transformerboard T IV, 1 mm, Aging in Air Degree of Polymerisation C 120 C 140 C Days
37 EXPERIMENT RESULT: D egree of Polymerisation Transformerboard T IV 1 mm Drying in air and in vacuum (dashed lines) vacuum vacuum vacuum 105 C 120 C 140 C Time (days)
38 POWER TRANSFORMER DP record: Pulp 1350 // new insulation 1200 // after drying 1000
39 EXAMPLE: Transformer life starts with DP 1000 versus 1200
40 CONCLUSION [T.V. Oommen, L.N. Arnold] Loss of transformer lifetime due to insulation drying: noticeable but not worrying DP years DP ½ years DP years
41 THANK YOU Questions??
MOISTURE IN PAPER ASSESSMENT FROM CONTINUOUS MONITORING OF MOISTURE IN OIL. GE Energy
MOISTURE IN PAPER ASSESSMENT FROM CONTINUOUS MONITORING OF MOISTURE IN OIL Jacques Aubin GE Energy Brian D Sparling Abstract Moisture content of solid insulation is a persistent concern for power transformer
More informationHow to Improve Grid Reliability and Asset Utilization as increasing energy demand and an aging infrastructure drives grid investment.
SMART INSULATION - The Next Major Breakthrough How to Improve Grid Reliability and Asset Utilization as increasing energy demand and an aging infrastructure drives grid investment. WICOR AMERICAS INC.
More informationWeidmann Electrical Technology. Presenter Thomas A. Prevost, Weidmann-ACTI
Estimation of Insulation Life Based on a Dual Temperature Aging Model Weidmann-ACTI Inc. Fifth Annual Technical Conference Albuquerque, NM Nov. 13-15, 2006 Thomas A. Prevost, Hans Peter Gasser Weidmann
More informationADDITIONAL CONTACT INFORMATION:
RENEWABLE ENERGY Experience in the industry Bringing renewable power economically to the end customer requires today s most efficient technologies. As a leader in reliable transformer design and manufacturing,
More informationThermal Aging Study of Cellulosic Materials in Natural Ester Liquid for Hybrid Insulation Systems
21, rue d Artois, F-758 PARIS CIGRE 212 http : //www.cigre.org D1-111 Thermal Aging Study of Cellulosic Materials in Natural Ester Liquid for Hybrid Insulation Systems J-C DUART * L. C. BATES R. ASANO
More informationMoisture equilibrium charts
Moisture equilibrium charts For effective condition monitoring of natural ester fluid-filled green transformers 04/29/2016-5.18 pm Clean Grid Green transformer Power transformers Green transformers, which
More informationMoisture Equilibrium and Moisture Migration Within Transformer Insulation System
Moisture Equilibrium and Moisture Migration Within Transformer Insulation System Tutorial of CIGRÉ WG A2.3 Conveners: Victor Sokolov, Ukraine Maik Koch, Germany 1 Outline Introduction: background and definitions
More informationB. Provide liquid-filled secondary substation transformers as indicated on drawings.
SECTION 26 12 13 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 26 05 00. B. Provide liquid-filled secondary substation transformers as indicated on drawings. 1.02 RELATED
More informationFrequently Asked Questions. 3M Liquid-Filled Transformer Insulation
Frequently Asked Questions 3M Liquid-Filled Transformer Insulation Frequently Asked Questions What configurations are available for 3M Liquid-Filled Transformer Insulation (LFT Insulation) layer insulation?
More informationTRANSFORMER S MOISTURE ASSESSMENT WITH ONLINE MONITORING
TRANSFORMER S MOISTURE ASSESSMENT WITH ONLINE MONITORING Senja LEIVO Vaisala Oyj Finland senja.leivo@vaisala.com Jukka LEPPÄNEN Vaisala Oyj Finland jukka.leppanen@vaisala.com ABSTRACT This paper discusses
More informationPomona, CA May 24 25, 2016
Pomona, CA May 24 25, 2016 Transformer Technology Seminar Modular approach on economic condition assessment for power transformer; data management, Fleet screening and risk ranking Siemens AG 2014 All
More informationCIGRE 16 BRUGGE Partial Discharge and Dissolved Gas Analysis In bio-degradable transformer oil. The University of New South Wales Australia
CIGRE 16 BRUGGE 2007 Partial Discharge and Dissolved Gas Analysis In bio-degradable transformer oil D. IMAMOVIC *, K.X. LAI, N.A. MUHAMAD, B.T. PHUNG and T.R. BLACKBURN # The University of New South Wales
More informationDistribution Transformer Failures In Port Harcourt
Global Advanced Research Journal of Engineering, Technology and Innovation (ISSN: 2315-5124) Vol. 3(7) pp. 202-206, November, 2014 Available online http://garj.org/garjeti/index.htm Copyright 2014 Global
More informationThe Next Step In The World Of Transformers
The Next Step In The World Of Transformers Envirotran TM Transformers Set Higher Environmental, Fire Safety and Performance Standards Envirotran TM Transformers Advance the Evolution of Electrical Distribution
More informationroduct Scope: Substation
roduct Scope: Substation Three Phase or Single Phase, 50 or 60 Hz, 55ºC, 65ºC, 75ºC, 55ºC/65ºC, 55ºC/75ºC, 65ºC/75ºC Envirotemp FR3 fluid or Mineral Oil Three Phase: 300 12,000 kva Single Phase: 167 6,667
More informationResin impregnated paper bushings. Product information
Resin impregnated paper bushings Product information This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor be used for any
More informationElectrical Research and Testing Laboratory Nuremberg
siemens.com/energy/transformers Electrical Research and Testing Laboratory Nuremberg Testing and research at the cutting edge of technology Answers for energy. The latest methods, outstanding expertise
More informationPROGRESS IN PAPER DEGRADATION ASSESSMENT IN SERVICE-AGED TRANSFORMERS
PROGRESS IN PAPER DEGRADATION ASSESSMENT IN SERVICE-AGED TRANSFORMERS H. Ding, R. Heywood, J. Lapworth, S. Ryder and A. Wilson Presenter: Dr Hongzhi Ding Doble PowerTest Ltd UK INSUCON - 17 th May 2017
More information9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA
9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA Technical specification for 9KV/18KV 5KA Metal oxide Lightning Arrestors without Gap. ----------------------------------------------------------------------------------------------------------------
More informationImproved Determination of Moisture in Oil-Paper-Insulations by Specialised Moisture Equilibrium Charts
Proceedings of the XIVth International Symposium on High Voltage Engineering, S. 8, Beijing, hina, Improved Determination of Moisture in Oil-Paper-Insulations by Specialised Moisture Equilibrium harts
More informationNOMEX TYPE 410 TECHNICAL DATA SHEET. Electrical properties. Please note: PERFORM WHEN THE HEAT S ON TYPICAL ELECTRICAL PROPERTIES
NOMEX TYPE 41 NOMEX Type 41 is a calendered insulation paper which offers high inherent dielectric strength, mechanical toughness, flexibility and resilience. NOMEX Type 41 is the original form of NOMEX
More informationANSI/IEEE Standard C57.12"Standard Guide for Loading Mineral Oil Insulated Transformers"
References: ANSI/IEEE Standard C57.12"Standard Guide for Loading Mineral Oil Insulated Transformers" IEEE Project P1276 "IEEE Guide for the Application of High Temperature Insulation Materials in Liquid
More informationBlack 1:1 Epoxy, Encapsulating & Potting Compound
Technical Data Sheet Black 1:1 Epoxy, Encapsulating & Potting Compound Description 832HD potting and encapsulating compound is a general purpose, hard, black, two-part epoxy that offers extreme environmental,
More informationAPEC 2016 Component Level Safety Certification in Systems- IEC /UL1577. MARK CANTRELL Senior Applications Engineer
APEC 2016 Component Level Safety Certification in Systems- IEC60747-17/UL1577 MARK CANTRELL Senior Applications Engineer 3/20/2016 Agenda What is safety isolation Isolation Concepts Regulatory Landscape
More informationHTP. HTP070 Purifier for Dielectric Fluids. PIH HTP070b
PIH HTP070b The HTP070 purifier permits treatment of the oil in a power transformer, while on-line and on-load. Application Areas The PALL HTP070 oil purifier removes water, solid particles, air and other
More informationSmart Grid Monitoring of Transformers by DGA. Michel Duval. CIGRE Thailand, Bangkok 2013
Smart Grid Monitoring of Transformers by DGA Michel Duval CIGRE Thailand, Bangkok 2013 1 Electric Power 2 Power Transformers 3 Catastrophic Failures 4 Failures in Service - The failure rate of power transformers
More informationTRANSFORMERS FOR OFFSHORE MULTI MEGAWATT TURBINES : DISCUSSION ON SPECIFICATIONS, SAFETY AND ENVIRONMENT
TRANSFORMERS FOR OFFSHORE MULTI MEGAWATT TURBINES : DISCUSSION ON SPECIFICATIONS, SAFETY AND ENVIRONMENT Dr. Ir. Jan Declercq, Ing. Raymond Van Schevensteen Pauwels International N.V., Antwerpsesteenweg
More informationMonolithic Isolation Fittings
Monolithic Isolation Fittings The Industry s Dual O Ring Seal Standard Tests Include: 100% Hydrostatic Pressure & Electrical Tests 100% Ultrasonic of Welds 100% Magnetic Particle of Welds 100% Dye Penetrant
More informationGrid Solutions. ASSET PERFORMANCE MANAGEMENT for Electrical Substations
Grid Solutions ASSET PERFORMANCE MANAGEMENT for Electrical Substations Electrical equipment is a critical component of an asset portfolio. Beyond its financial value, it plays an even greater role in overall
More informationMar11 Rev B
Product Specification 108-1163-7 11Mar11 Rev B Inverted Six and Eight Position Surface Mount Shielded Modular Jack Assembly 1. SCOPE 1.1. Content This specification covers performance, tests and quality
More informationTransmission Owner Asset Management
Transmission Owner Asset Management Pieces of Asset Management New customers, load growth, repairs, maintenance, operational issues, etc. All the pieces make up the asset management plan for repair or
More informationStudy Committee A3. High Voltage Equipment. Action Plan
Study Committee A3 High Voltage Equipment Action Plan October 2011 CIGRE Study Committee A3 - High Voltage Equipment Action Plan 1 Content 1 Content...2 2 Purpose of the Action Plan...3 3 Activities of
More informationTOGA PRESENTATION REVIEW OF CASE STUDIES. Paul Boman,
TOGA PRESENTATION REVIEW OF CASE STUDIES Paul Boman, paul_boman@hsb.com October 8, 2014 HSB s TOGA History TOGA Transformer Oil Gas Analyst Registered trademark of Hartford Steam Boiler Inspection and
More informationDEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 103, HUMIDITY (STEADY STATE)
INCH-POUND MIL-STD-202-103 18 April 2015 SUPERSEDING MIL-STD-202G w/change 2 (IN PART) 28 June 2013 (see 6.1) DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 103, HUMIDITY (STEADY STATE) AMSC N/A FSC
More informationPowering reliable solutions. for the commercial and industrial market
Powering reliable solutions for the commercial and industrial market We understand your challenges To maintain an uninterrupted operation, commercial and industrial users require the highest compliance
More informationFriday, May 29, Update on Testing Medium Voltage Cable and Switchgear Systems
Update on Testing Medium Voltage Cable and Switchgear Systems Friday, May 29, 2015 Presented by: Ashley Harkness Ashley.Harkness@Emerson.com Electrical Reliability Services Value--- When we find the one
More informationSECTION MEDIUM VOLTAGE TRANSFORMERS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the
More informationINNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES
INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES Dr. S. Ruhland, Dr. U. Riedl ALSTOM Sachsenwerk GmbH, Germany The requirements for medium voltage switchgear
More informationPower Transformers. Your partner in energy solutions
Power Transformers Your partner in energy solutions - 2 - Contents CG Power Systems. Smart Solutions, Strong Relationships 5 Transformer design 6 Quality Assurance 8 Core construction 9 Windings 10 Insulation
More informationInvestigation of leakage current flow through wooden poles structures on overhead distribution system
Proceedings of the 7th WSEAS International Conference on Power Systems, Beijing, China, September 15-17, 2007 120 Investigation of leakage current flow through wooden poles structures on overhead distribution
More informationUnderstanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF
Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF Why do we need to cover the SPF Spray Polyurethane Foam (SPF) is combustible As the SPF burns and
More informationPILC Replacement: Getting the Lead Out
PILC Replacement: Getting the Lead Out Spring Cincinnati, OH April 30, 2003 Page 1 PILC IS GREAT! Low Profile High Fault Current Capability on Shield High Degree of Water Blocking So why shouldn t you
More informationPRY-MOULD. High Voltage Accessories for Extruded Cables
PRY-MOULD High Voltage Accessories for Extruded Cables Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy
More informationAn Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application
An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application Introduction Designed for Indoor and outdoor applications Non-tension tap and splice applications Used
More informationBoosting Productivity and Quality in Slab Casting with ABB s Electromagnetic Systems
Boosting Productivity and Quality in Slab Casting with ABB s Electromagnetic Systems Complete Range of Products for Slab Production Ladle Furnace Stirrer give: Clean steel Improved yield of alloys Reliable
More informationFactors Affecting Current Ratings for Underground and Air Cables
Factors Affecting Current Ratings for Underground and Air Cables S. H. Alwan, J. Jasni, M. Z. A. Ab Kadir, N. Aziz Abstract The aim of this paper is to present a parametric study to determine the major
More informationU.V resistance UL Sunlight Resistance. Flame retardant IEC
Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial
More informationElectricity Supply to Africa and Developing Economies Challenges and Opportunities. Technology solutions and innovations for developing economies
Electricity Supply to Africa and Developing Economies Challenges and Opportunities Technology solutions and innovations for developing economies Employment of various strategies in Eskom to optimize the
More informationLA Engineering Academy
Laxmi Associates Consultancy Third party Inspection RLA Testing& Commissioning AMC Project Management Training 323-324, Sunplaza1, GIDC Road, Makarpura, Vadodara-390010. lxassociates@gmail.com, www.laxmiassociates.in,
More informationTransformer Life Extension. CJC V30 Transformer Oil Vacuum Filtration Unit and Ion Exchange Filtration Units
Transformer Life Extension CJC V30 Transformer Oil Vacuum Filtration Unit and Ion Exchange Filtration Units Agenda Examples of V30 installations Background info Theory Field results Added safety Conclusion
More informationPerformance of Oil and Paper in Transformers Based on IEC and Dielectric Response Techniques*
F E A T U R E A R T I C L E Performance of Oil and Paper in Transformers Based on IEC 61620 and Dielectric Response Techniques* Key words: oil paper insulation, transformer, polarization, conduction, aging
More informationDEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 106, MOISTURE RESISTANCE
INCH-POUND MIL-STD-202-106 18 April 2015 SUPERSEDING MIL-STD-202G w/change 2 (IN PART) 28 June 2013 (see 6.1) DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 106, MOISTURE RESISTANCE AMSC N/A FSC 59GP
More informationThermal Shock Test Chambers TS Series
ck to In S dyp a e R Shi to Thermal Shock Test Chambers TS Series TS Series - The Highest Standard for Thermal Shock Test Chambers We know what matters to you for your tests: reliable, precise and reproducible
More informationRosemount 1152 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment
More informationGUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR 220, 132 & 66 COMPOSITE SOLIDCORE STATION POST INSULATORS GETCO/E/2,1,6
More informationELECTRICAL RESINS FR TODAY AND TOMORRO SWITCH MODE POWER SUPPLY
ELECTRICAL RESINS FOR TODAY AND TOMORROW ELECTRICAL RESINS FR TODAY AND TOMORRO SWITCH MODE POWER SUPPLY SWITCH MODE POWER SUPPLY Presented by: Sean McCabe Head of Technical Department Impregnating Resins
More informationProduct Specification JUL 14 Rev. A1
Industrial SCSI Connector 1. Scope 1.1 Contents This specification covers the requirements for product performance, test methods and quality assurance provisions of SCSI Connector. 2. Applicable Documents
More informationManjunatha N. Area Sales Manager Exports Mob:
ABB India Ltd. Raman Boards 16th KM, Mysore Ooty Road Thandavapura 571302, Mysore Karnataka, INDIA Tel No: + 91 821 2536100 Fax No: + 91 8221 228608 abb.com/transformercomponents Contact Persons: Manjunatha
More informationAcceptable values for receipt of shipments of new FR3 fluid. As-received new fluid property requirements 1.0
Dielectric Fluids Envirotemp FR3 Fluid Electrical Apparatus R2000 DESCRIPTION Envirotemp FR3 fluid is a renewable, bio-based natural ester dielectric coolant for use in distribution and power class transformers
More informationScrew Compressors. DSD and ESD Series ( hp) Capacities from: 544 to 1522 cfm Pressures from: 80 to 217 psig. kaeser.com
Screw Compressors DSD and ESD Series (200-300 hp) Capacities from: 544 to 1522 cfm Pressures from: 80 to 217 psig kaeser.com DSD and ESD Series Built for a lifetime. Kaeser s DSD and ESD compressors are
More informationAdvice on Power Factor and Accuracy of Temperature Dependant Outputs
Advice on Power Factor and Accuracy of Temperature Dependant Outputs REPORT WP03749-EE-RP-0001 Rev. 1 3 September 2009 Advice on Power Factor and Accuracy of Temperature Dependant Outputs REPORT WP03749-EE-RP-0001
More informationModel FDL 115 Safety drying chambers for limited quantities of solvent
Model FDL 115 Safety drying chambers for limited quantities of solvent The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and
More informationDissolved Gas Analysis of Transformer Oils: Effects of electric arc
Proceedings of the 6th WSEAS International Conference on Power Systems, Lisbon, Portugal, September 22-24, 26 376 Dissolved Gas Analysis of Transformer Oils: Effects of electric arc SUWARNO School of Electrical
More informationUNS 5kA Arrester. Certified Test Report IEC
CP No.: CP0504 Page 1 of 10 UNS 5kA Arrester Certified Test Report IEC 60099-4 2004 CERTIFICATION Statements made and data shown are, to the best of our knowledge and belief, correct and within the usual
More informationSilicone Dielectric Fluids Fredi Jakob, Karl Jakob, Nicholas Perjanik Analytical ChemTech International, Inc.
Silicone Dielectric Fluids Fredi Jakob, Karl Jakob, Nicholas Perjanik Analytical ChemTech International, Inc. I. Introduction Mineral oil based dielectric fluids have been used more extensively than other
More informationSURGE ARRESTERS kv in silicone shield
SURGE ARRESTERS 10-24 kv in e shield The surge arresters 12 kv produced in Electotechnical Institute Division in Wroclaw (nominal discharge capability 10kA, 8/20µs) are presented on the picture. Advantages
More informationProduct-related services for switchgear, transformers, and cables
Product-related services for switchgear, transformers, and cables Making the most of your T&D assets Asset Services/Product-related services Switchgear Services Transformer Services Cable and Line Services
More informationSOT-23 Reliability November 23, 1998
SOT-23 Reliability SOT-23 Reliability November 23, 1998 By David B. Hutchins, Senior Applications Engineer Diodes Incorporated -- www.diodes.com Introduction Diodes Incorporated has offered high-quality
More informationBIOTEMP TRANSFORMERS IN THE MODERN SUBSTATION
International Colloquium Transformer Research and Asset Management Dubrovnik, Croatia, May 16 18, 2012 Cristiano Greggio ABB S.p.A. cristiano.greggio@it.abb.com Miljenko Hrkac ABB S.p.A. miljenko.hrkac@it.abb.com
More informationSeismic Considerations of Circuit Breakers
Seismic Considerations of Circuit Breakers Willie Freeman, IEEE 693 Working Group ABB Inc, Mt. Pleasant PA, USA IEEE Tutorial - 2008 Abstract: The tutorial covers the seismic qualification of high voltage
More informationAn Overview of Online Oil Monitoring Technologies
An Overview of Online Oil Monitoring Technologies Tim Cargol Weidmann-ACTI, Inc. 71 Bishop St., Framingham, MA 01702, USA tcargol@weidmann-acti.com Abstract Several new and exciting oil monitoring technologies
More informationCompact Substation Design. Kobus Coetzer TGOOD Africa
Compact Substation Design Kobus Coetzer TGOOD Africa 1. 2. 3. 4. TGOOD Electric Compact Substation Design Considerations Project Reference Agenda 1. TGOOD Electric Key Facts Sino German Joint Venture Leading
More informationREQUEST FOR PROPOSAL 18/24/30 MVA 138 kv to kv 3φ Power Transformers with LTC WEATHERFORD MUNICIPAL UTILITY SYSTEM
REQUEST FOR PROPOSAL 18/24/30 MVA 138 kv to 13.09 kv 3φ Power Transformers with LTC WEATHERFORD MUNICIPAL UTILITY SYSTEM SECTION I - SCOPE A. The Weatherford Municipal Utility System invites qualified
More informationROLINX Laminated Busbar. Design Rules Version 01 (12/2015)
ROLINX Laminated Busbar Design Rules Version 01 (12/2015) Content 1. Introduction... 03 7. Features... 13 2. Configuration...03 8. Thermal parameters... 14 3. Products... 04 9. General parameters... 14
More informationENERGY SOLUTIONS FOR THE GLOBAL POWER INDUSTRY
TRANSFORMERS ENERGY SOLUTIONS FOR THE GLOBAL POWER INDUSTRY BRUSH Transformers is globally renowned for the quality of its products, innovation and service. Our markets include the utility, oil, petrochemical,
More informationSite and Field Services
Site and Field www.narec.co.uk Site and Field Our specialist skills, project experience and field services equipment for conducting resource measurements, investigations and electrical testing provides
More informationThermally Conductive Epoxy Product No
PELCO T E C H N I C A L N O T E S DESCRIPTION Thermally Conductive Epoxy Product No. 16027 Product No. 16027 Thermally Conductive Epoxy, Encapsulating and Potting Compound, is an electric grade epoxy.
More informationProduct specification
Product specification For capacitor tissue paper, electrolytic paper, cable paper and insulating paper The paper factory SPO was established in June 1828. Our industrial production started with the manufacture
More informationRosemount 1154 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10
More informationMETHODOLOGY FOR ENERGY AUDITS IN POWER PLANTS REGARDING ANALYSIS OF ELECTRICAL ENERGY CONSUMPTION
METHODOLOGY FOR ENERGY AUDITS IN POWER PLANTS REGARDING ANALYSIS OF ELECTRICAL ENERGY CONSUMPTION Aleksandar NIKOLIĆ 1, El.eng. Institute Nikola Tesla, University of Belgrade, Serbia INTRODUCTION Electricity
More informationPrevious Page Return to Index Next Page
Previous Page Return to Index Next Page http://www.switchcraft.com/products/jack-107.html (1 of 8) [2/13/2005 2:31:54 PM] 3.5 mm SINGLE MONO AND STEREO JACKS 1. 35RAPC4BV4 2. 35RAPC2AV 3. 35RAPC2BHN2 4.
More informationmv & hv switchgears Installation Servicing Testing Commissioning
mv & hv switchgears Installation Servicing Testing Commissioning mission With exceptional professionalism we always exceed our customers' expectations by increasing their productivity and competitiveness
More informationnicrom e l e c t r o n i c
G E N E R A L High Performance Thick Film Resistors C A T A L O G 3 Nicrom Electronic Via Roncaglia CH - 6883 Novazzano SWITZERLAND Phone : ++4 () 9 68 99 86 Fax : ++4 () 9 68 99 86 info@nicrom-electronic.com
More informationRaychem brand Moulded Components Flame Retarded, Semi-Rigid, Heat Shrinkable, Elastomer (-25)
RW-2070 Revision 2 Page 1 of 8 Date Printed 18-Jul-12 RW-2070 Revision 2 Raychem brand Moulded Components Flame Retarded, Semi-Rigid, Heat Shrinkable, Elastomer (-25) SCOPE This Quality Assurance Specification
More informationNPS/002/020 Technical Specification for 11 & 20kV Power Cables
Version:- 3.1 of Issue:- Nov - 09 Page 1 of 11 NPS/002/020 Technical Specification for 11 & 20kV Power Cables 1. Purpose The purpose of this document is to detail Northern Powergrid (the Company) requirements
More informationSECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS
SECTION 26 22 13 HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS PART 1 GENERAL 1.1 WORK INCLUDED A. Dry-type, low-voltage, distribution transformers meeting US Department of Energy proposed Candidate Standard
More informationTechnical Bulletin No. 110 GAS BARRIER PROPERTIES OF RESINS
Technical Bulletin No. 110 GAS BARRIER PROPERTIES OF RESINS The most outstanding property of EVAL TM resins is their ability to provide a barrier to gases such as oxygen, nitrogen, carbon dioxide and helium.
More informationThe effectiveness of oil analysis for failure prediction of power transformers
The effectiveness of oil analysis for failure prediction of power transformers by Krige Visser and Yashin Brihmohan, University of Pretoria The availability of an electricity network is of utmost importance
More informationMOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast!
MOBILE SUBSTATIONS TRAILER AND SKID tgood.com Energy, Fast! Global leader in E-House and prefabricated substation solutions PRODUCT OVERVIEW Custom configurable skid-mounted and trailer-mounted designs.
More informationOnline data sheet SMC209 C CEMS SOLUTIONS
Online data sheet SMC209 C A B C D E F H I J K L M N O P Q R S T Ordering information Type SMC209 C Part no. On request The exact device specifications and performance data of the product may deviate from
More informationVERSAFIT V2 AND V4 TUBING Polyolefin, Flexible, Heat-Shrinkable, Flame-Retardant
TE Connectivity 300 Constitution Drive Menlo Park, CA 94025 USA Raychem Tubing Specification This Issue: Date: Replaces: RW-3023 Issue 9 Nov 21, 2016 Issue 8 VERSAFIT V2 AND V4 TUBING Polyolefin, Flexible,
More informationMeasurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum
Measurement & Analytics Measurement made easy AlSCAN TM and AlSCAN TM Argon Today s global economy and competition have compelled aluminum producers and aluminum foundries to produce the highest possible
More information094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA
094: 2000 CEB STANDARD MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA Specification for MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEB Standard
More informationThermoset Applications in Fuel Cells
Thermoset Applications in Fuel Cells TRFA 2008 Annual Meeting Sept. 15 th 2008 Paul Kozak & Daniel Ramrus B A L L A R D P O W E R S Y S T E M S A C C E L E R A T I N G F U E L C E L L M A R K E T A D O
More informationGROUND THAWING & CONCRETE CURING REFERENCE GUIDE.
GROUND THAWING & CONCRETE CURING REFERENCE GUIDE www.heat-king.ca TABLE OF CONTENTS Principles of Ground Thawing 2 Ground Thawing Illustration 3 Principles of Concrete Curing 5 Slab on Grade Illustration
More informationStandard for handling, packing, shipping and use of moisture/reflow sensitive surface mount devices
This is a preview - click here to buy the full publication,(&3$6 Edition 1.0 2000-08 Standard for handling, packing, shipping and use of moisture/reflow sensitive surface mount devices 38%/,&/
More informationBLOCKTITE SYSTEM WATER-REPELLENT ADMIXTURE CERTIFICATION PROGRAM
BLOCKTITE SYSTEM WATER-REPELLENT ADMIXTURE CERTIFICATION PROGRAM Mix Performance Worksheet Testing Procedures/Protocol Test Results, Calculations Certificate of Compliance The Euclid Chemical Company 19218
More information3.0) TRANSMISSION LINES MINIMUM REQUIRED STANDARDS LINES
3.0) TRANSMISSION LINES MINIMUM REQUIRED STANDARDS LINES 3.2 Underground Lines [below sections will be renumbered at a later date] 5.0 GENERAL REQUIREMENTS 5.1 Underground transmission lines 69 kv and
More information