WEIDMANN Electrical Technology. Presentation at. NETA Trade Show. March 15 th, 2016

Size: px
Start display at page:

Download "WEIDMANN Electrical Technology. Presentation at. NETA Trade Show. March 15 th, 2016"

Transcription

1 WEIDMANN Electrical Technology Presentation at NETA Trade Show March 15 th, 2016 WEIDMANN DIAGNOSTIC SOLUTIONS INC. A Member of the WICOR Group ELECTRICAL TECHNOLOGY

2 WICOR WORLDWIDE Company Overview

3 INSULATION - Power Transformer Company overview

4 Insulation - Distribution Transformers Insulation Overview

5 DRAWING NUMBER: Core leg 3rd Winding Core - Jack Ring Allowance Steel Jack Ring A 60 HZ BIL EQUIVALENT BIL / HR INDUCED LEVEL PHASE-PHASE Top Yoke or Jack Pad TX Jack Ring Bottom Yoke or Core Clamp 1 HR ENHANCED LEVEL PHASE-PHASE DELTA CONN. LEVEL 1 HR ENHANCED WYE CONN. PHASE-GROUND CREATED CHECKED ENGR. BY CONTRACT NUMBER CONTRACT APPROVAL DATE 3/04/93 THIRD FIRST ANGLE PROJECTION TITLE CUSTOMER NAME SIZE SCALE St. Johnsbury, VT Insulaton Clearances for Non-Steep Front/Non-Switching Surge Designs DRAWING NUMBER MAT CUSTOMER REF NO. SH. REV 1 OF 1 Insulation Overview Insulation System Design & Optimization Analyze Actual Design Develop New Design Analyze New Design Define Clearances Define Insulation Layout SK3493WP1 Insulation Clearances for NSF and NBSL Designs Voltage < VOLTAGES & BIL BIL APPLIED SETTING VOLTAGES A B C,D,E,F A CLEARANCES B C C TX Rings D WITH STATIC RING E LV Winding F E D C C HV HV Winding Winding Phase 1 B Phase 2 C1 Note: 1. Both C and C1 Minimums must be maintained. 2. End Clearances are taken from insulated static plate. 3. When Static Plates LV COIL are not present, takehv COIL HV COIL HV COIL End Clearances from insulated conductor. PHASE 1 PHASE 2 SK3493WP1 1 B R e l e a s e 1. 0 SECTION VIEW PHASE-PHASE SECTION VIEW

6 Progressive Diagnostics End User Segment - Diagnostic Services Oil Testing What sets us apart from our competition ISO Accredits competency of a laboratory to perform tests to industry standards: IEEE, IEC, ASTM. Rigorous requirements on employee competence, mgmt systems, equipment calibrations, laboratory physical environment, verification standard testing. Assure customers that laboratories follow standard exactly. Annual audits by 3 rd party auditors Only testing laboratories in US to have accreditation

7 Progressive Diagnostics Diagnostic Solutions Service Centers <2007 Original Labs 2000: Sacramento, CA Houston, TX Calgary, AB Philadelphia, PA Indianapolis, IN 2005 Burlington, ON 2009 Montreal, QC Denver, CO St. Johnsbury, VT (R&D) 2010 N. Canton, OH Saltillo, Mexico Shanghai, China Waukesha, WI TBD Poland Brazil Middle East Hubs/Satellites

8 Progressive Diagnostics ENGINEERING SERVICES Yoke OEM and Utility Transformer Engineering Design and Specification Analysis Power system(grid) analysis Power electronics 2D & 3D Electromagnetic studies for AC and HVDC transformers, rectifiers, switchgear, surge arresters, etc. Failure analysis Fleet Assessment Condition Assessment Thermal upgrades Factory and field inspections Commissioning/Decommissioning Ba

9 Information Management EDUCATION, TRAINING, AND KNOWLEDGE TRANSFER Technical Conferences Annual Client Technical Conf. Power Transformers Insulation Transformer Fluid Diagnostics Substation Maintenance and Diagnostics Regional/Local Seminars Group Training Events Customized training Offer Continuing Education Credits and IEEE and NETA Accreditations

10 Monitoring MONITOR PORTFOLIO / InsuLogix - GROWING FAMILY FOR OPTIMUM PERFORMANCE MONITORING (OPM) Sensors and Monitors B - Bushing 2013 T Mi F - Smart Insulation Integrator Platform InsuLogix Q Integrator Software enameplate (T) 2014 Health Index (T,Mp) H HM Q Multigas and Moisture 2012 WEIDMANN 2015 OPM (T,Mi,F) 2016 D - Dielectric Strength

11 Insulation Overview Complimentary Products and Logistics Services Warehousing and Inventory Mgmnt\

12 Moisture in Insulation and Transformer Dryout

13 TOPICS 1. Effects of moisture in Insulation 2. Moisture Absorption and Removal 3. Transformer Dryout Theory 4. Side effects on Dryout Process

14 Paper and Water in Transformers KVA Weight of 5% Initial Moisture Rating KV Paper (kg) kg/kva Kilograms Liters 3, , , , , , , Ref. S.D. Meyers Typically 90% of the initial moisture content will be removed to achieved a dryness of 0.5% moisture content

15 DISTRIBUTION OF WATER IN INSULATION Oil

16 HIGH MOISTURE CONTENT IN INSULATION CAN CAUSE: Significant Reduction in Dielectric Strength Accelerated Aging of the Cellulose Bubble Formation and Dielectric Failure Partial discharges in the Insulation Dry Cellulose < 0.3% by weight & Oil < 10 ppm H 2 O

17 MOISTURE CONTENT VS KV BREAKDOWN VOLTAGE Source: FM Clark Engineering Guide Book on Electrical Insulation

18 MOISTURE IN SOLID INSULATION KV Breakdown Voltage U(kV) Moisture Content x = 1% x = 4% x = 6% x = 8% x = 10% Power Factor Power factor tan (%) Temperature ( C ) Temperature ( C ) Moisture Content x = 1% x = 4% x = 6% x = 8% x = 10%

19 MOISTURE ACCELERATES AGEING PROCESS Source: H.P.Moser - Transformerboard

20 Critical temperature for bubble evolution 190 Kobayashi rapid heating 170 Kobayashi slow heating Temperature Davydov Oommen gas free 90 Oommen gas saturated WCP % w/w Ref. Sparling, Brian; GE Energy,

21 Topics 1. Effects of moisture in Insulation 2. Moisture Absorption and Removal 3. Transformer Dryout Theory 4. Side effects on Dryout Process

22 WHY DOES CELLULOSE ABSORRB WATER CHEMICAL BACKGROUND Due to the high number of hydroxyl-groups is the cellulose molecule very hydroscopic; meaning, these groups attract water molecules (H 2 O). CH 2 OH HO O HO OH O HO CH 2 OH OH O CH 2 OH O HO OH n - 2 OH

23 HOW MUCH WATER IS ABSORBED (AFTER LONG EXPOSURE TO AMBIENT) The amount of absorbed water is mainly governed by the relative humidity of the environment. It is hardly influenced by the type of cellulose used. The (relative) amount of water is not (or only marginally) dependent on: The thickness of the board / paper The density of the board / paper Temperature Oil impregnation (without / with oil)

24 HOW MUCH WATER IS ABSORBED (AFTER LONG EXPOSURE TO AMBIENT) Water content [%] low density Moisture equilibrium of Transformerboard at 23 C and 50% rh conditioned not oil impregnated high density low density oil impregnated high density Thickness [mm]

25 HOW FAST IS WATER ABSORBED How fast water is absorbed is governed by: The thickness of the board / paper The density of the board / paper Temperature Oil impregnation (without / with oil) Circulation of the surrounding medium (air / oil)

26 HOW FAST IS WATER ABSORBED Influence of the thickness Transformerboard T IV Water absorption [%] mm 3 mm 5 mm 8 mm Time [days]

27 HOW FAST IS WATER ABSORBED W a te r a b so rp tio n [% ] g/cm³ Influence of the density Board thickness 3 mm 1.25 g/cm³ Time [days]

28 HOW FAST IS WATER ABSORBED Influence of the temperature Transformerboard T IV, 3 mm W a te r a b s o rp tio n [% ] C 10 C Time [days]

29 HOW FAST IS WATER ABSORBED Influence of the oil impregnation Transformerboard T IV, 3 mm W ater absorption [%] not oil impregnated oil impregnated Time [days]

30 HOW FAST CAN WATER BE REMOVED FROM TRANSFORMERBOARD The drying process is a diffusion process. The rate of drying is therefore governed by the same parameters: Temperature Pressure Material thickness Material density Oil impregnated (without / with)

31 Topics 1. Effects of moisture in Insulation 2. Moisture Absorption and Removal 3. Transformer Dryout Theory 4. Side effects on Dryout Process

32 VACUUMING WITHOUT APPLICATION OF HEAT Heat of Vaporization Energy required to change from Liquid phase to Vapor phase..< Vacuum Level Study indicates that Vacuuming without application of heat : - No further benefit if > 24 hours - free room temperature 4 torr - heat of vaporization would lower the temperature to a point where remaining water will freeze making extensive vacuuming pointless Temperature > Good Practice Application of Heat multiple times during the Dryout Process

33 Topics 1. Effects of moisture in Insulation 2. Moisture Absorption and Removal 3. Transformer Dryout Theory 4. Side effects on Dryout Process

34 SIDE EFFECTS OF DRYING PROCESS 1. Effects on DP

35 EXPERIMENT EFFECTS ON DP Thin high-density pressboard samples (1 mm) Oven temperature: 105, 120, 140 C Time: 14 days Hot air circulation vs. Vacuum DP measurements during drying.

36 EXPERIMENT RESULT: Transformerboard T IV 1 mm Drying in air Transformerboard T IV, 1 mm, Aging in Air Degree of Polymerisation C 120 C 140 C Days

37 EXPERIMENT RESULT: D egree of Polymerisation Transformerboard T IV 1 mm Drying in air and in vacuum (dashed lines) vacuum vacuum vacuum 105 C 120 C 140 C Time (days)

38 POWER TRANSFORMER DP record: Pulp 1350 // new insulation 1200 // after drying 1000

39 EXAMPLE: Transformer life starts with DP 1000 versus 1200

40 CONCLUSION [T.V. Oommen, L.N. Arnold] Loss of transformer lifetime due to insulation drying: noticeable but not worrying DP years DP ½ years DP years

41 THANK YOU Questions??

MOISTURE IN PAPER ASSESSMENT FROM CONTINUOUS MONITORING OF MOISTURE IN OIL. GE Energy

MOISTURE IN PAPER ASSESSMENT FROM CONTINUOUS MONITORING OF MOISTURE IN OIL. GE Energy MOISTURE IN PAPER ASSESSMENT FROM CONTINUOUS MONITORING OF MOISTURE IN OIL Jacques Aubin GE Energy Brian D Sparling Abstract Moisture content of solid insulation is a persistent concern for power transformer

More information

How to Improve Grid Reliability and Asset Utilization as increasing energy demand and an aging infrastructure drives grid investment.

How to Improve Grid Reliability and Asset Utilization as increasing energy demand and an aging infrastructure drives grid investment. SMART INSULATION - The Next Major Breakthrough How to Improve Grid Reliability and Asset Utilization as increasing energy demand and an aging infrastructure drives grid investment. WICOR AMERICAS INC.

More information

Weidmann Electrical Technology. Presenter Thomas A. Prevost, Weidmann-ACTI

Weidmann Electrical Technology. Presenter Thomas A. Prevost, Weidmann-ACTI Estimation of Insulation Life Based on a Dual Temperature Aging Model Weidmann-ACTI Inc. Fifth Annual Technical Conference Albuquerque, NM Nov. 13-15, 2006 Thomas A. Prevost, Hans Peter Gasser Weidmann

More information

ADDITIONAL CONTACT INFORMATION:

ADDITIONAL CONTACT INFORMATION: RENEWABLE ENERGY Experience in the industry Bringing renewable power economically to the end customer requires today s most efficient technologies. As a leader in reliable transformer design and manufacturing,

More information

Thermal Aging Study of Cellulosic Materials in Natural Ester Liquid for Hybrid Insulation Systems

Thermal Aging Study of Cellulosic Materials in Natural Ester Liquid for Hybrid Insulation Systems 21, rue d Artois, F-758 PARIS CIGRE 212 http : //www.cigre.org D1-111 Thermal Aging Study of Cellulosic Materials in Natural Ester Liquid for Hybrid Insulation Systems J-C DUART * L. C. BATES R. ASANO

More information

Moisture equilibrium charts

Moisture equilibrium charts Moisture equilibrium charts For effective condition monitoring of natural ester fluid-filled green transformers 04/29/2016-5.18 pm Clean Grid Green transformer Power transformers Green transformers, which

More information

Moisture Equilibrium and Moisture Migration Within Transformer Insulation System

Moisture Equilibrium and Moisture Migration Within Transformer Insulation System Moisture Equilibrium and Moisture Migration Within Transformer Insulation System Tutorial of CIGRÉ WG A2.3 Conveners: Victor Sokolov, Ukraine Maik Koch, Germany 1 Outline Introduction: background and definitions

More information

B. Provide liquid-filled secondary substation transformers as indicated on drawings.

B. Provide liquid-filled secondary substation transformers as indicated on drawings. SECTION 26 12 13 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 26 05 00. B. Provide liquid-filled secondary substation transformers as indicated on drawings. 1.02 RELATED

More information

Frequently Asked Questions. 3M Liquid-Filled Transformer Insulation

Frequently Asked Questions. 3M Liquid-Filled Transformer Insulation Frequently Asked Questions 3M Liquid-Filled Transformer Insulation Frequently Asked Questions What configurations are available for 3M Liquid-Filled Transformer Insulation (LFT Insulation) layer insulation?

More information

TRANSFORMER S MOISTURE ASSESSMENT WITH ONLINE MONITORING

TRANSFORMER S MOISTURE ASSESSMENT WITH ONLINE MONITORING TRANSFORMER S MOISTURE ASSESSMENT WITH ONLINE MONITORING Senja LEIVO Vaisala Oyj Finland senja.leivo@vaisala.com Jukka LEPPÄNEN Vaisala Oyj Finland jukka.leppanen@vaisala.com ABSTRACT This paper discusses

More information

Pomona, CA May 24 25, 2016

Pomona, CA May 24 25, 2016 Pomona, CA May 24 25, 2016 Transformer Technology Seminar Modular approach on economic condition assessment for power transformer; data management, Fleet screening and risk ranking Siemens AG 2014 All

More information

CIGRE 16 BRUGGE Partial Discharge and Dissolved Gas Analysis In bio-degradable transformer oil. The University of New South Wales Australia

CIGRE 16 BRUGGE Partial Discharge and Dissolved Gas Analysis In bio-degradable transformer oil. The University of New South Wales Australia CIGRE 16 BRUGGE 2007 Partial Discharge and Dissolved Gas Analysis In bio-degradable transformer oil D. IMAMOVIC *, K.X. LAI, N.A. MUHAMAD, B.T. PHUNG and T.R. BLACKBURN # The University of New South Wales

More information

Distribution Transformer Failures In Port Harcourt

Distribution Transformer Failures In Port Harcourt Global Advanced Research Journal of Engineering, Technology and Innovation (ISSN: 2315-5124) Vol. 3(7) pp. 202-206, November, 2014 Available online http://garj.org/garjeti/index.htm Copyright 2014 Global

More information

The Next Step In The World Of Transformers

The Next Step In The World Of Transformers The Next Step In The World Of Transformers Envirotran TM Transformers Set Higher Environmental, Fire Safety and Performance Standards Envirotran TM Transformers Advance the Evolution of Electrical Distribution

More information

roduct Scope: Substation

roduct Scope: Substation roduct Scope: Substation Three Phase or Single Phase, 50 or 60 Hz, 55ºC, 65ºC, 75ºC, 55ºC/65ºC, 55ºC/75ºC, 65ºC/75ºC Envirotemp FR3 fluid or Mineral Oil Three Phase: 300 12,000 kva Single Phase: 167 6,667

More information

Resin impregnated paper bushings. Product information

Resin impregnated paper bushings. Product information Resin impregnated paper bushings Product information This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor be used for any

More information

Electrical Research and Testing Laboratory Nuremberg

Electrical Research and Testing Laboratory Nuremberg siemens.com/energy/transformers Electrical Research and Testing Laboratory Nuremberg Testing and research at the cutting edge of technology Answers for energy. The latest methods, outstanding expertise

More information

PROGRESS IN PAPER DEGRADATION ASSESSMENT IN SERVICE-AGED TRANSFORMERS

PROGRESS IN PAPER DEGRADATION ASSESSMENT IN SERVICE-AGED TRANSFORMERS PROGRESS IN PAPER DEGRADATION ASSESSMENT IN SERVICE-AGED TRANSFORMERS H. Ding, R. Heywood, J. Lapworth, S. Ryder and A. Wilson Presenter: Dr Hongzhi Ding Doble PowerTest Ltd UK INSUCON - 17 th May 2017

More information

9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA

9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA 9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA Technical specification for 9KV/18KV 5KA Metal oxide Lightning Arrestors without Gap. ----------------------------------------------------------------------------------------------------------------

More information

Improved Determination of Moisture in Oil-Paper-Insulations by Specialised Moisture Equilibrium Charts

Improved Determination of Moisture in Oil-Paper-Insulations by Specialised Moisture Equilibrium Charts Proceedings of the XIVth International Symposium on High Voltage Engineering, S. 8, Beijing, hina, Improved Determination of Moisture in Oil-Paper-Insulations by Specialised Moisture Equilibrium harts

More information

NOMEX TYPE 410 TECHNICAL DATA SHEET. Electrical properties. Please note: PERFORM WHEN THE HEAT S ON TYPICAL ELECTRICAL PROPERTIES

NOMEX TYPE 410 TECHNICAL DATA SHEET. Electrical properties. Please note: PERFORM WHEN THE HEAT S ON TYPICAL ELECTRICAL PROPERTIES NOMEX TYPE 41 NOMEX Type 41 is a calendered insulation paper which offers high inherent dielectric strength, mechanical toughness, flexibility and resilience. NOMEX Type 41 is the original form of NOMEX

More information

ANSI/IEEE Standard C57.12"Standard Guide for Loading Mineral Oil Insulated Transformers"

ANSI/IEEE Standard C57.12Standard Guide for Loading Mineral Oil Insulated Transformers References: ANSI/IEEE Standard C57.12"Standard Guide for Loading Mineral Oil Insulated Transformers" IEEE Project P1276 "IEEE Guide for the Application of High Temperature Insulation Materials in Liquid

More information

Black 1:1 Epoxy, Encapsulating & Potting Compound

Black 1:1 Epoxy, Encapsulating & Potting Compound Technical Data Sheet Black 1:1 Epoxy, Encapsulating & Potting Compound Description 832HD potting and encapsulating compound is a general purpose, hard, black, two-part epoxy that offers extreme environmental,

More information

APEC 2016 Component Level Safety Certification in Systems- IEC /UL1577. MARK CANTRELL Senior Applications Engineer

APEC 2016 Component Level Safety Certification in Systems- IEC /UL1577. MARK CANTRELL Senior Applications Engineer APEC 2016 Component Level Safety Certification in Systems- IEC60747-17/UL1577 MARK CANTRELL Senior Applications Engineer 3/20/2016 Agenda What is safety isolation Isolation Concepts Regulatory Landscape

More information

HTP. HTP070 Purifier for Dielectric Fluids. PIH HTP070b

HTP. HTP070 Purifier for Dielectric Fluids. PIH HTP070b PIH HTP070b The HTP070 purifier permits treatment of the oil in a power transformer, while on-line and on-load. Application Areas The PALL HTP070 oil purifier removes water, solid particles, air and other

More information

Smart Grid Monitoring of Transformers by DGA. Michel Duval. CIGRE Thailand, Bangkok 2013

Smart Grid Monitoring of Transformers by DGA. Michel Duval. CIGRE Thailand, Bangkok 2013 Smart Grid Monitoring of Transformers by DGA Michel Duval CIGRE Thailand, Bangkok 2013 1 Electric Power 2 Power Transformers 3 Catastrophic Failures 4 Failures in Service - The failure rate of power transformers

More information

TRANSFORMERS FOR OFFSHORE MULTI MEGAWATT TURBINES : DISCUSSION ON SPECIFICATIONS, SAFETY AND ENVIRONMENT

TRANSFORMERS FOR OFFSHORE MULTI MEGAWATT TURBINES : DISCUSSION ON SPECIFICATIONS, SAFETY AND ENVIRONMENT TRANSFORMERS FOR OFFSHORE MULTI MEGAWATT TURBINES : DISCUSSION ON SPECIFICATIONS, SAFETY AND ENVIRONMENT Dr. Ir. Jan Declercq, Ing. Raymond Van Schevensteen Pauwels International N.V., Antwerpsesteenweg

More information

Monolithic Isolation Fittings

Monolithic Isolation Fittings Monolithic Isolation Fittings The Industry s Dual O Ring Seal Standard Tests Include: 100% Hydrostatic Pressure & Electrical Tests 100% Ultrasonic of Welds 100% Magnetic Particle of Welds 100% Dye Penetrant

More information

Grid Solutions. ASSET PERFORMANCE MANAGEMENT for Electrical Substations

Grid Solutions. ASSET PERFORMANCE MANAGEMENT for Electrical Substations Grid Solutions ASSET PERFORMANCE MANAGEMENT for Electrical Substations Electrical equipment is a critical component of an asset portfolio. Beyond its financial value, it plays an even greater role in overall

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1163-7 11Mar11 Rev B Inverted Six and Eight Position Surface Mount Shielded Modular Jack Assembly 1. SCOPE 1.1. Content This specification covers performance, tests and quality

More information

Transmission Owner Asset Management

Transmission Owner Asset Management Transmission Owner Asset Management Pieces of Asset Management New customers, load growth, repairs, maintenance, operational issues, etc. All the pieces make up the asset management plan for repair or

More information

Study Committee A3. High Voltage Equipment. Action Plan

Study Committee A3. High Voltage Equipment. Action Plan Study Committee A3 High Voltage Equipment Action Plan October 2011 CIGRE Study Committee A3 - High Voltage Equipment Action Plan 1 Content 1 Content...2 2 Purpose of the Action Plan...3 3 Activities of

More information

TOGA PRESENTATION REVIEW OF CASE STUDIES. Paul Boman,

TOGA PRESENTATION REVIEW OF CASE STUDIES. Paul Boman, TOGA PRESENTATION REVIEW OF CASE STUDIES Paul Boman, paul_boman@hsb.com October 8, 2014 HSB s TOGA History TOGA Transformer Oil Gas Analyst Registered trademark of Hartford Steam Boiler Inspection and

More information

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 103, HUMIDITY (STEADY STATE)

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 103, HUMIDITY (STEADY STATE) INCH-POUND MIL-STD-202-103 18 April 2015 SUPERSEDING MIL-STD-202G w/change 2 (IN PART) 28 June 2013 (see 6.1) DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 103, HUMIDITY (STEADY STATE) AMSC N/A FSC

More information

Powering reliable solutions. for the commercial and industrial market

Powering reliable solutions. for the commercial and industrial market Powering reliable solutions for the commercial and industrial market We understand your challenges To maintain an uninterrupted operation, commercial and industrial users require the highest compliance

More information

Friday, May 29, Update on Testing Medium Voltage Cable and Switchgear Systems

Friday, May 29, Update on Testing Medium Voltage Cable and Switchgear Systems Update on Testing Medium Voltage Cable and Switchgear Systems Friday, May 29, 2015 Presented by: Ashley Harkness Ashley.Harkness@Emerson.com Electrical Reliability Services Value--- When we find the one

More information

SECTION MEDIUM VOLTAGE TRANSFORMERS

SECTION MEDIUM VOLTAGE TRANSFORMERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES

INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES Dr. S. Ruhland, Dr. U. Riedl ALSTOM Sachsenwerk GmbH, Germany The requirements for medium voltage switchgear

More information

Power Transformers. Your partner in energy solutions

Power Transformers. Your partner in energy solutions Power Transformers Your partner in energy solutions - 2 - Contents CG Power Systems. Smart Solutions, Strong Relationships 5 Transformer design 6 Quality Assurance 8 Core construction 9 Windings 10 Insulation

More information

Investigation of leakage current flow through wooden poles structures on overhead distribution system

Investigation of leakage current flow through wooden poles structures on overhead distribution system Proceedings of the 7th WSEAS International Conference on Power Systems, Beijing, China, September 15-17, 2007 120 Investigation of leakage current flow through wooden poles structures on overhead distribution

More information

Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF

Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF Why do we need to cover the SPF Spray Polyurethane Foam (SPF) is combustible As the SPF burns and

More information

PILC Replacement: Getting the Lead Out

PILC Replacement: Getting the Lead Out PILC Replacement: Getting the Lead Out Spring Cincinnati, OH April 30, 2003 Page 1 PILC IS GREAT! Low Profile High Fault Current Capability on Shield High Degree of Water Blocking So why shouldn t you

More information

PRY-MOULD. High Voltage Accessories for Extruded Cables

PRY-MOULD. High Voltage Accessories for Extruded Cables PRY-MOULD High Voltage Accessories for Extruded Cables Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy

More information

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application Introduction Designed for Indoor and outdoor applications Non-tension tap and splice applications Used

More information

Boosting Productivity and Quality in Slab Casting with ABB s Electromagnetic Systems

Boosting Productivity and Quality in Slab Casting with ABB s Electromagnetic Systems Boosting Productivity and Quality in Slab Casting with ABB s Electromagnetic Systems Complete Range of Products for Slab Production Ladle Furnace Stirrer give: Clean steel Improved yield of alloys Reliable

More information

Factors Affecting Current Ratings for Underground and Air Cables

Factors Affecting Current Ratings for Underground and Air Cables Factors Affecting Current Ratings for Underground and Air Cables S. H. Alwan, J. Jasni, M. Z. A. Ab Kadir, N. Aziz Abstract The aim of this paper is to present a parametric study to determine the major

More information

U.V resistance UL Sunlight Resistance. Flame retardant IEC

U.V resistance UL Sunlight Resistance. Flame retardant IEC Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial

More information

Electricity Supply to Africa and Developing Economies Challenges and Opportunities. Technology solutions and innovations for developing economies

Electricity Supply to Africa and Developing Economies Challenges and Opportunities. Technology solutions and innovations for developing economies Electricity Supply to Africa and Developing Economies Challenges and Opportunities Technology solutions and innovations for developing economies Employment of various strategies in Eskom to optimize the

More information

LA Engineering Academy

LA Engineering Academy Laxmi Associates Consultancy Third party Inspection RLA Testing& Commissioning AMC Project Management Training 323-324, Sunplaza1, GIDC Road, Makarpura, Vadodara-390010. lxassociates@gmail.com, www.laxmiassociates.in,

More information

Transformer Life Extension. CJC V30 Transformer Oil Vacuum Filtration Unit and Ion Exchange Filtration Units

Transformer Life Extension. CJC V30 Transformer Oil Vacuum Filtration Unit and Ion Exchange Filtration Units Transformer Life Extension CJC V30 Transformer Oil Vacuum Filtration Unit and Ion Exchange Filtration Units Agenda Examples of V30 installations Background info Theory Field results Added safety Conclusion

More information

Performance of Oil and Paper in Transformers Based on IEC and Dielectric Response Techniques*

Performance of Oil and Paper in Transformers Based on IEC and Dielectric Response Techniques* F E A T U R E A R T I C L E Performance of Oil and Paper in Transformers Based on IEC 61620 and Dielectric Response Techniques* Key words: oil paper insulation, transformer, polarization, conduction, aging

More information

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 106, MOISTURE RESISTANCE

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 106, MOISTURE RESISTANCE INCH-POUND MIL-STD-202-106 18 April 2015 SUPERSEDING MIL-STD-202G w/change 2 (IN PART) 28 June 2013 (see 6.1) DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 106, MOISTURE RESISTANCE AMSC N/A FSC 59GP

More information

Thermal Shock Test Chambers TS Series

Thermal Shock Test Chambers TS Series ck to In S dyp a e R Shi to Thermal Shock Test Chambers TS Series TS Series - The Highest Standard for Thermal Shock Test Chambers We know what matters to you for your tests: reliable, precise and reproducible

More information

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Rosemount 1152 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment

More information

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR 220, 132 & 66 COMPOSITE SOLIDCORE STATION POST INSULATORS GETCO/E/2,1,6

More information

ELECTRICAL RESINS FR TODAY AND TOMORRO SWITCH MODE POWER SUPPLY

ELECTRICAL RESINS FR TODAY AND TOMORRO SWITCH MODE POWER SUPPLY ELECTRICAL RESINS FOR TODAY AND TOMORROW ELECTRICAL RESINS FR TODAY AND TOMORRO SWITCH MODE POWER SUPPLY SWITCH MODE POWER SUPPLY Presented by: Sean McCabe Head of Technical Department Impregnating Resins

More information

Product Specification JUL 14 Rev. A1

Product Specification JUL 14 Rev. A1 Industrial SCSI Connector 1. Scope 1.1 Contents This specification covers the requirements for product performance, test methods and quality assurance provisions of SCSI Connector. 2. Applicable Documents

More information

Manjunatha N. Area Sales Manager Exports Mob:

Manjunatha N. Area Sales Manager Exports Mob: ABB India Ltd. Raman Boards 16th KM, Mysore Ooty Road Thandavapura 571302, Mysore Karnataka, INDIA Tel No: + 91 821 2536100 Fax No: + 91 8221 228608 abb.com/transformercomponents Contact Persons: Manjunatha

More information

Acceptable values for receipt of shipments of new FR3 fluid. As-received new fluid property requirements 1.0

Acceptable values for receipt of shipments of new FR3 fluid. As-received new fluid property requirements 1.0 Dielectric Fluids Envirotemp FR3 Fluid Electrical Apparatus R2000 DESCRIPTION Envirotemp FR3 fluid is a renewable, bio-based natural ester dielectric coolant for use in distribution and power class transformers

More information

Screw Compressors. DSD and ESD Series ( hp) Capacities from: 544 to 1522 cfm Pressures from: 80 to 217 psig. kaeser.com

Screw Compressors. DSD and ESD Series ( hp) Capacities from: 544 to 1522 cfm Pressures from: 80 to 217 psig. kaeser.com Screw Compressors DSD and ESD Series (200-300 hp) Capacities from: 544 to 1522 cfm Pressures from: 80 to 217 psig kaeser.com DSD and ESD Series Built for a lifetime. Kaeser s DSD and ESD compressors are

More information

Advice on Power Factor and Accuracy of Temperature Dependant Outputs

Advice on Power Factor and Accuracy of Temperature Dependant Outputs Advice on Power Factor and Accuracy of Temperature Dependant Outputs REPORT WP03749-EE-RP-0001 Rev. 1 3 September 2009 Advice on Power Factor and Accuracy of Temperature Dependant Outputs REPORT WP03749-EE-RP-0001

More information

Model FDL 115 Safety drying chambers for limited quantities of solvent

Model FDL 115 Safety drying chambers for limited quantities of solvent Model FDL 115 Safety drying chambers for limited quantities of solvent The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and

More information

Dissolved Gas Analysis of Transformer Oils: Effects of electric arc

Dissolved Gas Analysis of Transformer Oils: Effects of electric arc Proceedings of the 6th WSEAS International Conference on Power Systems, Lisbon, Portugal, September 22-24, 26 376 Dissolved Gas Analysis of Transformer Oils: Effects of electric arc SUWARNO School of Electrical

More information

UNS 5kA Arrester. Certified Test Report IEC

UNS 5kA Arrester. Certified Test Report IEC CP No.: CP0504 Page 1 of 10 UNS 5kA Arrester Certified Test Report IEC 60099-4 2004 CERTIFICATION Statements made and data shown are, to the best of our knowledge and belief, correct and within the usual

More information

Silicone Dielectric Fluids Fredi Jakob, Karl Jakob, Nicholas Perjanik Analytical ChemTech International, Inc.

Silicone Dielectric Fluids Fredi Jakob, Karl Jakob, Nicholas Perjanik Analytical ChemTech International, Inc. Silicone Dielectric Fluids Fredi Jakob, Karl Jakob, Nicholas Perjanik Analytical ChemTech International, Inc. I. Introduction Mineral oil based dielectric fluids have been used more extensively than other

More information

SURGE ARRESTERS kv in silicone shield

SURGE ARRESTERS kv in silicone shield SURGE ARRESTERS 10-24 kv in e shield The surge arresters 12 kv produced in Electotechnical Institute Division in Wroclaw (nominal discharge capability 10kA, 8/20µs) are presented on the picture. Advantages

More information

Product-related services for switchgear, transformers, and cables

Product-related services for switchgear, transformers, and cables Product-related services for switchgear, transformers, and cables Making the most of your T&D assets Asset Services/Product-related services Switchgear Services Transformer Services Cable and Line Services

More information

SOT-23 Reliability November 23, 1998

SOT-23 Reliability November 23, 1998 SOT-23 Reliability SOT-23 Reliability November 23, 1998 By David B. Hutchins, Senior Applications Engineer Diodes Incorporated -- www.diodes.com Introduction Diodes Incorporated has offered high-quality

More information

BIOTEMP TRANSFORMERS IN THE MODERN SUBSTATION

BIOTEMP TRANSFORMERS IN THE MODERN SUBSTATION International Colloquium Transformer Research and Asset Management Dubrovnik, Croatia, May 16 18, 2012 Cristiano Greggio ABB S.p.A. cristiano.greggio@it.abb.com Miljenko Hrkac ABB S.p.A. miljenko.hrkac@it.abb.com

More information

Seismic Considerations of Circuit Breakers

Seismic Considerations of Circuit Breakers Seismic Considerations of Circuit Breakers Willie Freeman, IEEE 693 Working Group ABB Inc, Mt. Pleasant PA, USA IEEE Tutorial - 2008 Abstract: The tutorial covers the seismic qualification of high voltage

More information

An Overview of Online Oil Monitoring Technologies

An Overview of Online Oil Monitoring Technologies An Overview of Online Oil Monitoring Technologies Tim Cargol Weidmann-ACTI, Inc. 71 Bishop St., Framingham, MA 01702, USA tcargol@weidmann-acti.com Abstract Several new and exciting oil monitoring technologies

More information

Compact Substation Design. Kobus Coetzer TGOOD Africa

Compact Substation Design. Kobus Coetzer TGOOD Africa Compact Substation Design Kobus Coetzer TGOOD Africa 1. 2. 3. 4. TGOOD Electric Compact Substation Design Considerations Project Reference Agenda 1. TGOOD Electric Key Facts Sino German Joint Venture Leading

More information

REQUEST FOR PROPOSAL 18/24/30 MVA 138 kv to kv 3φ Power Transformers with LTC WEATHERFORD MUNICIPAL UTILITY SYSTEM

REQUEST FOR PROPOSAL 18/24/30 MVA 138 kv to kv 3φ Power Transformers with LTC WEATHERFORD MUNICIPAL UTILITY SYSTEM REQUEST FOR PROPOSAL 18/24/30 MVA 138 kv to 13.09 kv 3φ Power Transformers with LTC WEATHERFORD MUNICIPAL UTILITY SYSTEM SECTION I - SCOPE A. The Weatherford Municipal Utility System invites qualified

More information

ROLINX Laminated Busbar. Design Rules Version 01 (12/2015)

ROLINX Laminated Busbar. Design Rules Version 01 (12/2015) ROLINX Laminated Busbar Design Rules Version 01 (12/2015) Content 1. Introduction... 03 7. Features... 13 2. Configuration...03 8. Thermal parameters... 14 3. Products... 04 9. General parameters... 14

More information

ENERGY SOLUTIONS FOR THE GLOBAL POWER INDUSTRY

ENERGY SOLUTIONS FOR THE GLOBAL POWER INDUSTRY TRANSFORMERS ENERGY SOLUTIONS FOR THE GLOBAL POWER INDUSTRY BRUSH Transformers is globally renowned for the quality of its products, innovation and service. Our markets include the utility, oil, petrochemical,

More information

Site and Field Services

Site and Field Services Site and Field www.narec.co.uk Site and Field Our specialist skills, project experience and field services equipment for conducting resource measurements, investigations and electrical testing provides

More information

Thermally Conductive Epoxy Product No

Thermally Conductive Epoxy Product No PELCO T E C H N I C A L N O T E S DESCRIPTION Thermally Conductive Epoxy Product No. 16027 Product No. 16027 Thermally Conductive Epoxy, Encapsulating and Potting Compound, is an electric grade epoxy.

More information

Product specification

Product specification Product specification For capacitor tissue paper, electrolytic paper, cable paper and insulating paper The paper factory SPO was established in June 1828. Our industrial production started with the manufacture

More information

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

Rosemount 1154 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10

More information

METHODOLOGY FOR ENERGY AUDITS IN POWER PLANTS REGARDING ANALYSIS OF ELECTRICAL ENERGY CONSUMPTION

METHODOLOGY FOR ENERGY AUDITS IN POWER PLANTS REGARDING ANALYSIS OF ELECTRICAL ENERGY CONSUMPTION METHODOLOGY FOR ENERGY AUDITS IN POWER PLANTS REGARDING ANALYSIS OF ELECTRICAL ENERGY CONSUMPTION Aleksandar NIKOLIĆ 1, El.eng. Institute Nikola Tesla, University of Belgrade, Serbia INTRODUCTION Electricity

More information

Previous Page Return to Index Next Page

Previous Page Return to Index Next Page Previous Page Return to Index Next Page http://www.switchcraft.com/products/jack-107.html (1 of 8) [2/13/2005 2:31:54 PM] 3.5 mm SINGLE MONO AND STEREO JACKS 1. 35RAPC4BV4 2. 35RAPC2AV 3. 35RAPC2BHN2 4.

More information

mv & hv switchgears Installation Servicing Testing Commissioning

mv & hv switchgears Installation Servicing Testing Commissioning mv & hv switchgears Installation Servicing Testing Commissioning mission With exceptional professionalism we always exceed our customers' expectations by increasing their productivity and competitiveness

More information

nicrom e l e c t r o n i c

nicrom e l e c t r o n i c G E N E R A L High Performance Thick Film Resistors C A T A L O G 3 Nicrom Electronic Via Roncaglia CH - 6883 Novazzano SWITZERLAND Phone : ++4 () 9 68 99 86 Fax : ++4 () 9 68 99 86 info@nicrom-electronic.com

More information

Raychem brand Moulded Components Flame Retarded, Semi-Rigid, Heat Shrinkable, Elastomer (-25)

Raychem brand Moulded Components Flame Retarded, Semi-Rigid, Heat Shrinkable, Elastomer (-25) RW-2070 Revision 2 Page 1 of 8 Date Printed 18-Jul-12 RW-2070 Revision 2 Raychem brand Moulded Components Flame Retarded, Semi-Rigid, Heat Shrinkable, Elastomer (-25) SCOPE This Quality Assurance Specification

More information

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

NPS/002/020 Technical Specification for 11 & 20kV Power Cables Version:- 3.1 of Issue:- Nov - 09 Page 1 of 11 NPS/002/020 Technical Specification for 11 & 20kV Power Cables 1. Purpose The purpose of this document is to detail Northern Powergrid (the Company) requirements

More information

SECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS

SECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS SECTION 26 22 13 HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS PART 1 GENERAL 1.1 WORK INCLUDED A. Dry-type, low-voltage, distribution transformers meeting US Department of Energy proposed Candidate Standard

More information

Technical Bulletin No. 110 GAS BARRIER PROPERTIES OF RESINS

Technical Bulletin No. 110 GAS BARRIER PROPERTIES OF RESINS Technical Bulletin No. 110 GAS BARRIER PROPERTIES OF RESINS The most outstanding property of EVAL TM resins is their ability to provide a barrier to gases such as oxygen, nitrogen, carbon dioxide and helium.

More information

The effectiveness of oil analysis for failure prediction of power transformers

The effectiveness of oil analysis for failure prediction of power transformers The effectiveness of oil analysis for failure prediction of power transformers by Krige Visser and Yashin Brihmohan, University of Pretoria The availability of an electricity network is of utmost importance

More information

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast!

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast! MOBILE SUBSTATIONS TRAILER AND SKID tgood.com Energy, Fast! Global leader in E-House and prefabricated substation solutions PRODUCT OVERVIEW Custom configurable skid-mounted and trailer-mounted designs.

More information

Online data sheet SMC209 C CEMS SOLUTIONS

Online data sheet SMC209 C CEMS SOLUTIONS Online data sheet SMC209 C A B C D E F H I J K L M N O P Q R S T Ordering information Type SMC209 C Part no. On request The exact device specifications and performance data of the product may deviate from

More information

VERSAFIT V2 AND V4 TUBING Polyolefin, Flexible, Heat-Shrinkable, Flame-Retardant

VERSAFIT V2 AND V4 TUBING Polyolefin, Flexible, Heat-Shrinkable, Flame-Retardant TE Connectivity 300 Constitution Drive Menlo Park, CA 94025 USA Raychem Tubing Specification This Issue: Date: Replaces: RW-3023 Issue 9 Nov 21, 2016 Issue 8 VERSAFIT V2 AND V4 TUBING Polyolefin, Flexible,

More information

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum Measurement & Analytics Measurement made easy AlSCAN TM and AlSCAN TM Argon Today s global economy and competition have compelled aluminum producers and aluminum foundries to produce the highest possible

More information

094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA

094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA 094: 2000 CEB STANDARD MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA Specification for MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEB Standard

More information

Thermoset Applications in Fuel Cells

Thermoset Applications in Fuel Cells Thermoset Applications in Fuel Cells TRFA 2008 Annual Meeting Sept. 15 th 2008 Paul Kozak & Daniel Ramrus B A L L A R D P O W E R S Y S T E M S A C C E L E R A T I N G F U E L C E L L M A R K E T A D O

More information

GROUND THAWING & CONCRETE CURING REFERENCE GUIDE.

GROUND THAWING & CONCRETE CURING REFERENCE GUIDE. GROUND THAWING & CONCRETE CURING REFERENCE GUIDE www.heat-king.ca TABLE OF CONTENTS Principles of Ground Thawing 2 Ground Thawing Illustration 3 Principles of Concrete Curing 5 Slab on Grade Illustration

More information

Standard for handling, packing, shipping and use of moisture/reflow sensitive surface mount devices

Standard for handling, packing, shipping and use of moisture/reflow sensitive surface mount devices This is a preview - click here to buy the full publication,(&3$6 Edition 1.0 2000-08 Standard for handling, packing, shipping and use of moisture/reflow sensitive surface mount devices 38%/,&/

More information

BLOCKTITE SYSTEM WATER-REPELLENT ADMIXTURE CERTIFICATION PROGRAM

BLOCKTITE SYSTEM WATER-REPELLENT ADMIXTURE CERTIFICATION PROGRAM BLOCKTITE SYSTEM WATER-REPELLENT ADMIXTURE CERTIFICATION PROGRAM Mix Performance Worksheet Testing Procedures/Protocol Test Results, Calculations Certificate of Compliance The Euclid Chemical Company 19218

More information

3.0) TRANSMISSION LINES MINIMUM REQUIRED STANDARDS LINES

3.0) TRANSMISSION LINES MINIMUM REQUIRED STANDARDS LINES 3.0) TRANSMISSION LINES MINIMUM REQUIRED STANDARDS LINES 3.2 Underground Lines [below sections will be renumbered at a later date] 5.0 GENERAL REQUIREMENTS 5.1 Underground transmission lines 69 kv and

More information