1 T H E O F F I C I A L P U B L I CAT I O N O F 12 Save Money With Substation Maintenance 22 Grid-Tied Wind Energy Systems 28 Distributed Energy Storage and Utilities, Commercial Buildings Intelligent Load Management YOUR POWER DELIVERY MEDIA SOURCE

2 S BY CURT HICKCOX, public UTILITIES MAINTENANCE INC. The electricity delivery system operating in the U.S. and the rest of the world is one of the greatest engineering feats in history. Its design, construction and reliable operation is one of the most critical assets to our daily lives. This system, the electric grid, comprises high-voltage transmission circuits mainly supported by steel structures that transport electricity from the generation plants to substations where transformers, breakers and other equipment adjust the electricity s voltages before it is sent to distribution lines and structures that deliver the electricity to homes and businesses. This system is the backbone of the power delivery system that connects and interconnects each utility company with its customers. In the U.S. alone, there are more than 200,000 miles of high-voltage transmission lines, 10,300 transmission substations and 2,200 distribution substations. Substation equipment includes some 12,200 autotransformers, 195,000 oil circuit breakers, 64,000 transformers, 26,000 voltage regulators, plus the associated structural steel, bus-work, switchgear and foundations. Virtually all the equipment is made of painted steel that is susceptible to corrosive attack from atmospheric exposure. Even the structures, often constructed of galvanized steel, are subject to corrosive deterioration. Because corrosion causes equipment failures that result in service disruption, electric utilities must minimize corrosion through practices that include engineering design during construction and installation, as well as established maintenance programs throughout the service life. The direct cost of corrosion in the U.S. electric transmission and distribution segment is some $700 million annually. Many U.S. electric utilities maintain their substation and distribu- Curt Hickcox is vice president of Public Utilities Maintenance Inc., an SSPC-certified and ISO-registered corrosion control contractor specializing in the global electric transmission and distribution industry. He is a member of IEEE, NACE and SSPC and is chairman or vice chairman of three joint task groups responsible for transmission and distribution coatings-related standards. For more information, visit Reach Hickcox at curthickcox@puminc.com.

3 tion assets by preventing and controlling corrosion. They understand the criticality of substations to their system reliability and how corrosion can damage these components. But often and for various reasons, utilities are reactive rather than proactive when dealing with corrosion. Dealing with corrosion can be expensive, and dealing with it after the fact only increases the cost. But these expenses pale compared with the costs of a failure and resulting service outage. Properly planned and executed prevention programs control and minimize upfront expenditures while maintaining system reliability. Corrosion is controlled primarily through painting and generally is considered a maintenance, operational or revenue expense. Unfortunately, most utilities fund these types of expenses only minimally because they usually are considered a charge against profit rather than a profit generator as a capital expenditure would be. Available funds are funneled toward expenditures that help the bottom line, but the bottom line suffers more as the result of a corrosionrelated failure than by spending money upfront on prevention and maintenance. Construction of the U.S. high-voltage transmission system and its corresponding distribution system peaked in the 1970s (see figure). Most transmission lines were built from the 1960s through the 1990s. Nearly 75 percent of the North American electric grid was built during these 40 years. The age of these transmission lines and their large numbers will increase the amount of maintenance work required to keep the system safe and reliable. Because there are so many substations of the same general vintage, many will require corrosion repair during the same time, which will stretch resources and budgets. A utility can control its spending at a more consistent rate by being proactive with its maintenance program, which will allow for better planning and costeffectiveness that will result in higher reliability and profitability. A recent Associated Press study found Service interruptions can be prevented with correct inspections and proper maintenance. electric customers are spending 43 percent more than they did in 2002 to build and maintain the electric infrastructure. Since then, the number of power outages has remained infrequent, but it takes longer to restore service. One conclusion is the system is not being maintained and upgraded in a way that improves its reliability. It s another indication of a reactive approach: spending money to fix a problem rather than spending it to prevent one. Since 2002, there has been a 15 percent increase in the annual number of minutes the average customer is without power (although the number of outages slightly decreased), but spending per customer on local distribution equipment and maintenance rose at twice the rate of inflation. This seems to indicate that because of the distribution system s age, it is getting more expensive to maintain the system s high level of reliability. Although the U.S. electric distribution system has serious corrosion issues, it is

4 not all gloom and doom. Many utilities have implemented programs to deal with corrosion in their substations and have eliminated corrosion-related service disruptions. Industry organizations such as the International Electronic and Electrical Engineers Association (IEEE), the Electric Power Research Institute (EPRI) and the National Association of Corrosion Engineers (NACE) have established task groups and are researching and publishing standards relating to substation corrosion. The federal and state regulatory agencies also have started taking note of the condition of the electric grid, and, in some cases, have begun to mandate remediation and improvements. Proven methods of controlling corrosion exist, and with a little effort and dedicated funding, corrosion-related electric service disruptions can be eliminated. The first step is to assess the distribution system. A utility must understand the condition of its system before it can determine what needs to be done and the cost. The assessment should include a visual inspection of the system components, a condition rating per industry guidelines, prioritization based on the utility s requirements (i.e., component criticality, condition, logistics and outage limitations), surface preparation and coating system requirements and cost estimates. Simple testing, such as for lead in the existing coatings and coating film thickness and adhesion, should be performed as part of the assessment. NACE and IEEE joint task groups are writing standards that reference corrosion control in the transmission and distribution industry that include details on performing coating assessments on transmission and distribution structures. These standards should be published by the end of Once the assessment is complete, a defined program can be developed using a specific time frame and other criteria that conform to the utility s long-range plans. Upon funding, a project scope can be assembled easily using the assessment as its basis, followed by job award to a qualified contractor. It is critical that only contractors and workers with specific substation training and experience be allowed to bid on this work. Aside from demonstrated capabilities in preparing and coating complex electric distribution equipment, the contractors must have excellent safety records with health and safety programs specific to substation structures and equipment. The project specification must be tailored to the scope and not generic. A coating schedule that details surface preparation and coating system requirements is integral to the specification, as is a listing of all applicable safety rules and regulations. Various surface-preparation methods for steel surfaces may be employed in a substation. Power washing and abrasive blasting should not be used in an operating substation because of potential safety and damage issues. The Society for Protective Coatings (SSPC) has published surface-preparation standards widely specified throughout the industrial coatings industry, and certain standards ranging from solvent cleaning to hand and power tool cleaning to chemical stripping are applicable in substations, as well. The idea is to have a clean, dry, sound substrate free of contamination, peeling and flaking coatings and loose rust before application of the new coating system. The unique configuration and sensitive nature of many types of electric distribution equipment,

5 especially transformers and their cooling radiators, can make it difficult to properly prepare before coating, but many methods are available to prepare the surfaces. Again, a contractor with specific experience in transformer painting is crucial to the project s success. The application of protective coatings also presents challenges because of equipment configuration, as well as procedural and safety constraints associated with working near energized electrical equipment. Spray application usually is not allowed, and the standard hand methods of coating application such as brush and roller, although acceptable on breakers, tanks, etc., are not conducive to proper coating coverage on radiator banks. Flow coating, a specialized paint application technique, is a process similar to dipping radiator tubes. A recirculating system comprising a low-pressure pump, hoses, specially designed nozzle and collection setup allows the coating to reach and covers nooks, crannies and crevices on the radiator tube surfaces. Proper and consistent paint viscosity is required. Although the process is complicated, it is the only application method available for field use that ensures complete coverage of a radiator s surface area. The thickness of the paint film is impor- tant because a too-thin film does not provide adequate corrosion resistance, and a too-thick film can interfere with radiator cooling efficiency. No other method of field application can access and coat these areas, and only a contractor experienced in this application method should perform flow coating. Flow coating also is used for surface preparation on the radiators because often chemical stripping is the only way to remove suspect coatings from surfaces inside the fin banks where hand-cleaning methods cannot access. The U.S. has an electric transmission and distribution system made of aging structures and equipment. Service interruptions because of failures from corrosion are a fact, but they can be prevented by a proactive approach that includes correct inspections and proper maintenance. Proven methods of ensuring the long-term, cost-effective protection of the system exist. Experience has proven the viability and benefits of formal maintenance coatings programs for steel substation structures and equipment. Eprinted and posted with permission to Public Utilities Maintenance, Inc. from PowerGrid International October 2013 PennWell Corporation

6 Public Utilities Maintenance, Inc. What can we do for YOU? where others see rust... we see a blank canvas. Public Utilities Maintenance, Inc. offers corrosion control solutions in different industries. Please look at our list of services below to see if we can help you. Please contact us for more information. Steel Structure Coatings, Footing Inspection and Repair Specialists. Since 1992 Public Utilities Maintenance has met the unique painting needs of the Utility Industries: Electric, Gas, Communication, Water, and Fuel, around the world. Our Management team have over 100 years combined experience working on and managing painting projects. Certifications: ISO 9001:2008 (Quality Management System) SSPC - QP1 (Field Application Coatings) SSPC - QP2 (Industrial Hazardous Paint Removal) Services We Provide Painting / Coatings Services: Transmission Towers & Steel Poles Substation Structures & Equipment Flow-Coating Transformers Antenna / Microwave Towers Power & Gas Plants Tanks & Piping (Water, Gas, Oil, Penstock) Elevated Structures Lead Removal: Regulatory Compliant Containment Design & Installation Specialized Services: Coatings / Corrosion Inspections Steel Plate & Lattice Member Fabrication Public Utilities Maintenance, Inc th Avenue Queens Village, NY Office: Fax: info@puminc.com Website:

Transmission Tower Maintenance Bottom Line Savings Through Active Maintenance

Transmission Tower Maintenance Bottom Line Savings Through Active Maintenance Transmission Tower Maintenance Bottom Line Savings Through Active Maintenance Introduction Transmission towers/poles are among an electrical utility s largest and most important commercial assets. Unfortunately,

More information

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc. Protective Coatings for Underground Utility Concrete Structures By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc. As our cities and municipalities grow older, the utility and wastewater

More information

Joint Surface Preparation Standard. NACE No. 3/SSPC-SP 6 Commercial Blast Cleaning

Joint Surface Preparation Standard. NACE No. 3/SSPC-SP 6 Commercial Blast Cleaning Item No. 21067 Joint Surface Preparation Standard NACE No. 3/SSPC-SP 6 Commercial Blast Cleaning This NACE International (NACE)/SSPC: The Society for Protective Coatings standard represents a consensus

More information

Power Zone Center. Your solution for power distribution and control systems

Power Zone Center. Your solution for power distribution and control systems Power Zone Center Your solution for power distribution and control systems The Strength of One Powerful When you need to install a new power distribution center in your facility, you need it done in fastest

More information

Coating Application Specialist (CAS): The New Standard for Quality, Safety, and Reliability in Industrial Painting. White Paper. v2.

Coating Application Specialist (CAS): The New Standard for Quality, Safety, and Reliability in Industrial Painting. White Paper. v2. White Paper Coating Application Specialist (CAS): v2.0 The New Standard for Quality, Safety, and Reliability in Industrial Painting Copyright 2013 by the Finishing Solutions Network Abstract The costs

More information

vinyl ester Property Test/Standard Description semi gloss (35-70) Flash point ISO 3679 Method 1 34 C calculated IED (2010/75/EU) (theoretical)

vinyl ester Property Test/Standard Description semi gloss (35-70) Flash point ISO 3679 Method 1 34 C calculated IED (2010/75/EU) (theoretical) Approved 408;21800;21820;21740;21760;21840 1,2 408 ^(ValidationDate) 1 Product description This is a glass flake reinforced coating. It is an ultra high build, extremely chemical resistant and fast curing

More information

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong) Approved 402;2522 1,2 2522 zinc epoxy ^(ValidationDate) 1 Product description This is a two component polyamide cured zinc rich epoxy coating. It is a high zinc dust containing product. It conforms to

More information

SSPC: The Society for Protective Coatings. Commercial Blast Cleaning

SSPC: The Society for Protective Coatings. Commercial Blast Cleaning SSPC: The Society for Protective Coatings Joint Surface Preparation Standard SSPC-SP 6/NACE No. 3 Commercial Blast Cleaning This The Society for Protective Coatings (SSPC)/NACE International (NACE) standard

More information

Refining Corrosion Technologist NACE-RCT-001

Refining Corrosion Technologist NACE-RCT-001 Refining Corrosion Technologist NACE-RCT-001 NACE Coating Inspector Level 1 Written Exam Exam Preparation Guide October 2017 Exam Preparation Guide May 2017 1 Table of Contents Introduction... 3 Target

More information

POLYGUARD RD-6 A FAIL SAFE PIPELINE COATING SYSTEM FOR REHABILITATION OR GIRTH WELDS ON CATHODICALLY PROTECTED PIPELINES

POLYGUARD RD-6 A FAIL SAFE PIPELINE COATING SYSTEM FOR REHABILITATION OR GIRTH WELDS ON CATHODICALLY PROTECTED PIPELINES POLYGUARD RD-6 A FAIL SAFE PIPELINE COATING SYSTEM FOR REHABILITATION OR GIRTH WELDS ON CATHODICALLY PROTECTED PIPELINES A large percent of corrosion failures on cathodically protected structures are associated

More information

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Cycloaliphatic Amine Epoxy Highly chemical resistant epoxy mastic coating with exceptionally versatile uses in all industrial

More information

There are many surface contaminants that can interfere with coating adhesion. The following are the most common:

There are many surface contaminants that can interfere with coating adhesion. The following are the most common: ATB-103 General Coating Preparation Guidelines Introduction In real estate, the key phrase is Location! Location! Location! With paints and coatings, the phrase is Preparation! Preparation! Preparation!

More information

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant DESCRIPTION: SP-9888 Pipe Lining is based on the latest Zero VOC Novolac Technology. The product cures to a highly cross-linked coating with excellent chemical, solvent and water immersion resistance.

More information

Refer to Substrates & Surface Preparation.

Refer to Substrates & Surface Preparation. SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Dry Film Thickness Aliphatic Acrylic Polyurethane Thin film, high gloss finish with exceptional weathering performance

More information

Rust-Oleum Industrial Brands Specification

Rust-Oleum Industrial Brands Specification Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 2 A solvent based coating system High Performance 9100/9800 System DTM Epoxy Mastic/DTM

More information

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong Approved 20920;16620 1 20920 epoxy ^(ValidationDate) 1 Product description This is a two component amine cured epoxy coating. It is a fast drying, zinc phosphate pigmented, high solids, high build product.

More information

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL 1. SCOPE 2. DESIGN 3. MATERIALS 4. CONSTRUCTION 5. METHOD OF MEASUREMENT AND PAYMENT SCOPE This Specification sets out requirements for the design,

More information

Measured in accordance with ASTM D 2697.

Measured in accordance with ASTM D 2697. SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Service Temperature Solvent Based Inorganic Zinc Ultra-low VOC member of the Carbozinc family with extraordinary corrosion

More information

Maximum Rust Protection!

Maximum Rust Protection! ZERO-RUST Zero Rust is a direct-to-metal, phenolic modified alkyd rust and corrosion control coating, which controls rust and corrosion by putting down an impermeable barrier at the steel level. Its dielectric

More information

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Corlar 2.1 PR-P High Solids Productive Epoxy Primer Corlar 2.1 PR-P High Solids Productive Epoxy Primer GENERAL DESCRIPTION A high solids, two component, VOC conforming (2.1 lbs./gal.) Low HAPS productive primer based on Axalta modified polyamide epoxy

More information

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators GENERAL DESCRIPTION A high solids, two component, high build, VOC conforming (2.1 lbs./gal.) Low HAPS

More information

SURFACE PREPARATION BEFORE PAINTING

SURFACE PREPARATION BEFORE PAINTING SURFACE PREPARATION: For any given paint system, surface preparation is the single important factor which would determine its performance. Various surface preparation methods are adopted depending on the

More information

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

PRODUCT GUIDE: ZINC-RICH COATINGS. Version: PRODUCT GUIDE: ZINC-RICH COATINGS Version: 08.07.17 305 Zinc Rich Epoxy Polyamide Primer Description: 305 is a user friendly zinc-rich epoxy primer formulated for use as a primer under acrylic, epoxy,

More information

PPG Guide Specification

PPG Guide Specification PPG Guide Specification Coil and Extrusion Coatings, Liquid and Powder Coating Systems SECTION 050513 - SHOP-APPLIED COATINGS FOR METAL SECTION 05080 - FACTORY-APPLIED METAL COATINGS Revised October 2,

More information

Wood Pole Restoration

Wood Pole Restoration Osmo-C-Truss 50th Anniversary 2015 marks the 50th anniversary of the Osmo-C-Truss wood pole restoration system. Installations of the CTruss and C2-TrussTM have restored over 1 million poles nationwide.

More information

Property Test/Standard Description

Property Test/Standard Description Approved 29560;29561 1 29560 zinc silicate ^(ValidationDate) 1 Product description This is a two component ceramically reinforced polyamide cured zinc rich epoxy coating. 1:1 mixing ratio for easy use

More information

Special Provision No. 911F04 March 1997

Special Provision No. 911F04 March 1997 COATING STEEL RAILING SYSTEM(S) - Item No. Special Provision No. 911F04 March 1997 Definitions, Elimination of Pre-Start Material Sample, Material Requirements, Operational Constraints, Time Between Surface

More information

Aliphatic Acrylic-Polyester Polyurethane

Aliphatic Acrylic-Polyester Polyurethane SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Dry Film Thickness Aliphatic Acrylic-Polyester Polyurethane High build, low sheen finish that has excellent resistance

More information

Table of Contents. List of Drawings

Table of Contents. List of Drawings SCOPE OF WORK Hastings Stadium Exhibition Park, 81 London Road, Guelph, Ontario Structural and Maintenance Remedial Work Prepared For City of Guelph City Hall, 1 Carden Street, Guelph, ON N1H 3A1 Prepared

More information

Property Test/Standard Description

Property Test/Standard Description Approved 720 1,2 720 silicone acrylic ^(ValidationDate) 1 Product description This is a one component physically drying silicone acrylic coating. It is heat resistant up to 600 C. Can be used as primer,

More information

Steel structures Power industry Telecommunication

Steel structures Power industry Telecommunication Steel structures Power industry Telecommunication www.weldon.pl Power transmission towers Steel structures Power industry Telecommunication About us - We have been on the market for over 15 years. - We

More information

PERFORMANCE OF COATINGS OVER WATERJETTED SURFACES J. PETER AULT, P.E. ELZLY TECHNOLOGY CORPORATION

PERFORMANCE OF COATINGS OVER WATERJETTED SURFACES J. PETER AULT, P.E. ELZLY TECHNOLOGY CORPORATION PERFORMANCE OF COATINGS OVER WATERJETTED SURFACES J. PETER AULT, P.E. ELZLY TECHNOLOGY CORPORATION LEARNING OBJECTIVES THIS WEBINAR WILL EXPLORE ISSUES ASSOCIATED WITH WATERJETTING SURFACE PREPARATION

More information

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9080 - Concrete Steps, Handrails, and Safety Rail CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART - GENERAL.0 SECTION INCLUDES

More information

PRIMERS & SURFACE PREPARATION GUIDE

PRIMERS & SURFACE PREPARATION GUIDE PRIMERS & SURFACE PREPARATION GUIDE Era Polymers Primers & Surface Preparation Guide 1 There are three responses when looking at a coated surface yes, no, and WOW! Wow is the one to aim for. Era Polymers

More information

Bharat Heavy Electricals Limited Piping Centre Chennai-17. Specification Number Revision Number Sheet Number PC:E:GF: of 7 CONTENTS

Bharat Heavy Electricals Limited Piping Centre Chennai-17. Specification Number Revision Number Sheet Number PC:E:GF: of 7 CONTENTS PC:E:GF:001 00 2 of 7 CONTENTS 1 SCOPE 2 PRODUCT SPECIFICATION 3 SURFACE PREPARATION 4 PRIMING 5 COATING 6 FIELD JOINTING 7 INSPECTION AND TESTING PC:E:GF:001 00 3 of 7 Technical Specification for Glass

More information

Concrete and H2S Gas in Wet Wells and Tanks. James Orr - Project Manager NACE Inspector - Dixon Engineering

Concrete and H2S Gas in Wet Wells and Tanks. James Orr - Project Manager NACE Inspector - Dixon Engineering Concrete and H2S Gas in Wet Wells and Tanks James Orr - Project Manager NACE Inspector - Dixon Engineering What can H2S Gas do to Concrete????????? Ho Chunk WWTP Influent Wet Well Recoating Project Influent

More information

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

TL-280 Sprayable Flake Glass Vinyl Ester Lining System TL-280 Sprayable Flake Glass Vinyl Ester Lining System PRODUCT DESCRIPTION TL-280 is a high performance, flake glass vinyl ester lining system, utilizing carefully selected and sized glass flake reinforcement

More information

Application Guidelines

Application Guidelines Application Guidelines 1.0 SCOPE This document contains general instructions and recommended practices for the application of the SERVIWRAP cold applied tape coating system. The various coating grades

More information

Refer to Substrates & Surface Preparation.

Refer to Substrates & Surface Preparation. SELECTION & SPECIFICATION DATA Generic Type Description Features Aliphatic Acrylic Polyurethane High gloss finish with exceptional weathering performance characteristics. Used extensively in virtually

More information

Industrial Coatings. Protect your application by choosing the proper coating.

Industrial Coatings. Protect your application by choosing the proper coating. Industrial Coatings Protect your application by choosing the proper coating. Industrial Coatings: Overview Industrial Coatings are here to protect your applications and choosing the proper coating can

More information

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description Approved 7461;7680 1,2 7680 zinc epoxy ^(ValidationDate) 1 Product description This is a two component polyamide cured zinc rich epoxy coating. It is a high solids, high zinc dust containing product. It

More information

nalcofabtech.com A Nalco Champion Company

nalcofabtech.com A Nalco Champion Company nalcofabtech.com A Nalco Champion Company 2 CONTENTS Goal Zero - Safety Culture...4 About Us...6 Capabilities...8 Services...24 Equipment and Facilities... 36 3 4 At Nalco FabTech, our programs ensure

More information

Corrosion Under Insulation Detection Methods and Inspection

Corrosion Under Insulation Detection Methods and Inspection Corrosion Under Insulation Detection Methods and Inspection June 18, 2013 NACE Section Meeting James Higgins PetroChem Inspection OVERVIEW General causes of CUI Suspect Areas- how to find and where to

More information

MINIMIZING POLLUTION FROM CHEMICAL PRETREATMENT PROCESSES

MINIMIZING POLLUTION FROM CHEMICAL PRETREATMENT PROCESSES MINIMIZING POLLUTION FROM CHEMICAL PRETREATMENT PROCESSES Copyright Ron Joseph & Associates, Inc. All rights rwerved. January 1991. part of this publication may be reproduced or distributed in any form

More information

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. POLYURETHANE COATING ON STEEL PIPE PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2 REFERENCE SPECIFICATIONS,

More information

Grid Solutions. ASSET PERFORMANCE MANAGEMENT for Electrical Substations

Grid Solutions. ASSET PERFORMANCE MANAGEMENT for Electrical Substations Grid Solutions ASSET PERFORMANCE MANAGEMENT for Electrical Substations Electrical equipment is a critical component of an asset portfolio. Beyond its financial value, it plays an even greater role in overall

More information

PAYING ATTENTION TO DETAIL by Bob Cusumano

PAYING ATTENTION TO DETAIL by Bob Cusumano PAYING ATTENTION TO DETAIL by Bob Cusumano Painting contractors are often required to install caulk or sealant in exterior joints. Too often, the sealant is simply gunned into the joint until it s filled

More information

RESOLUTION MSC.244(83) (adopted on 5 October 2007) ADOPTION OF PERFORMANCE STANDARD FOR PROTECTIVE COATINGS FOR VOID SPACES ON BULK CARRIERS AND OIL

RESOLUTION MSC.244(83) (adopted on 5 October 2007) ADOPTION OF PERFORMANCE STANDARD FOR PROTECTIVE COATINGS FOR VOID SPACES ON BULK CARRIERS AND OIL MSC 83/28/Add.2 COATINGS FOR VOID SPACES ON BULK CARRIERS AND OIL TANKERS THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning

More information

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C. Approved 402;2521 1,2 2521 zinc epoxy ^(ValidationDate) 1 Product description This is a two component polyamide cured zinc rich epoxy coating. It is a very high zinc dust containing product. It conforms

More information

PRESERVING LOUISIANA S INFRASTRUCTURE: US190 MISSISSIPPI RIVER BRIDGE

PRESERVING LOUISIANA S INFRASTRUCTURE: US190 MISSISSIPPI RIVER BRIDGE PRESERVING LOUISIANA S INFRASTRUCTURE: US190 MISSISSIPPI RIVER BRIDGE Overview 1. Project Objectives 2. Bridge Data 3. Timeline 4. Existing Condition 5. Sequence of Coating and Repair Operations 6. Major

More information

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces. Product Information Chemical Products Division CHEMGLAZE B 9942 A/B Coating for Casting Pits. FEATURES BENEFITS. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces. Will build to

More information

Moisture Tolerant Technology. The Moisture Tolerant Technology Based Systems For Maintenance and Repair of Ballast Tanks

Moisture Tolerant Technology. The Moisture Tolerant Technology Based Systems For Maintenance and Repair of Ballast Tanks Moisture Tolerant Technology The Moisture Tolerant Technology Based Systems For Maintenance and Repair of Ballast Tanks As the ship s crew battle to control corrosion, paint failure due to high humidity,

More information

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027 Page 1 of 7 This document provides information and details for the use and application of Hi-Temp 1027. It is designed to supplement the Hi-Temp 1027 Product Data sheet (PDS) and MSDS, not to replace them.

More information

Introduction. Jeremy Hailey, P.E.

Introduction. Jeremy Hailey, P.E. Introduction Jeremy Hailey, P.E. Engineer with 16 years experience Started NW 10 years ago Focus on corrosion control system designs, troubleshooting, and some installation work Conduct training seminars

More information

HYDROJETTING INFORMATION. a six page issue October 1999

HYDROJETTING INFORMATION. a six page issue October 1999 a six page issue Hydrojetting is the surface preparation of steel using high-energy water to remove coatings, corrosion products and other surface contamination such as oil/grease etc. It relies totally

More information

Property Test/Standard Description

Property Test/Standard Description Approved 32222;32223;35142 1 32222 epoxy composite ^(ValidationDate) 1 Product description This is a two component glass flake reinforced epoxy composite coating. It is heat resistant up to 250 C (482

More information

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)

More information

Pioneer Forced Draft Cooling Tower Specifications

Pioneer Forced Draft Cooling Tower Specifications Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower

More information

FINAL REPORT: LARGE SCALE ACCELERATED CUI TEST OF E-2000 AND E-1100EG

FINAL REPORT: LARGE SCALE ACCELERATED CUI TEST OF E-2000 AND E-1100EG FINAL REPORT: LARGE SCALE ACCELERATED CUI TEST OF E-2000 AND E-1100EG Prepared for: Elisha Technologies Company L.L.C. P.O. Box 280 Moberly, Missouri 65270 Prepared by: Dr. Russell D. Kane InterCorr International,

More information

PRODUCT DATA SHEET Sika Unitherm Platinum

PRODUCT DATA SHEET Sika Unitherm Platinum PRODUCT DATA SHEET Solvent free, ultra high build, two pack, modified epoxy resin based, intumescent fire protection coating for internally or externally exposed structural steel. Ideal for in-shop application.

More information

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements. TECHNICAL SPECIFICATIONS SEWER MANHOLE REHABILITATION SYSTEM WITH A PROTECTIVE CEMENT LINER AND HIGH BUILD EPOXY COATING (As Provided by Standard Cement Materials) FOREWORD The following specification

More information

two component high build amine adduct cured phenolic epoxy primer

two component high build amine adduct cured phenolic epoxy primer 5 pages Revision of January 2003 DESCRIPTION two component high build amine adduct cured phenolic epoxy primer PRINCIPAL CHARACTERISTICS primer coat in the Sigma Phenguard tank coating system excellent

More information

Corrosion and Performance Issues for Immersion Service Shell and Tube Heat Exchangers

Corrosion and Performance Issues for Immersion Service Shell and Tube Heat Exchangers Corrosion and Performance Issues for Immersion Service Shell and Tube Heat Exchangers Condenser & Heat Exchanger Applications Tubesheet coatings Tube-end ID coatings Full-length tube coatings Waterbox

More information

STANDARD INSPECTION OF GUY ANCHORS IN DIRECT CONTACT WITH SOIL. Rev: 4/06

STANDARD INSPECTION OF GUY ANCHORS IN DIRECT CONTACT WITH SOIL. Rev: 4/06 STANDARD INSPECTION OF GUY ANCHORS IN DIRECT CONTACT WITH SOIL Rev: 4/06 INSPECTION OF GUY ANCHORS IN DIRECT CONTACT WITH SOIL Commentary - Guy anchors in direct contact with soil have proven to be susceptible

More information

Thin Film Internal Epoxy Coating for Pipelines

Thin Film Internal Epoxy Coating for Pipelines Technical and professional requirements TR1114, Version 1.01, Valid from 13.11.2003 Validity area: Classification: Open Contents 1 Introduction...3 1.1 Objective...3 1.2 Warrant...3 1.3 Publication and

More information

FIVE STAR PRODUCTS, INC. (800)

FIVE STAR PRODUCTS, INC.  (800) FIVE STAR PRODUCTS, INC. www.fivestarproducts.com (800) 243-2206 Page 1 of 11 DESIGN-A-SPEC GUIDELINES FIVE STAR RS ANCHOR GEL CONTENTS PART A - GENERAL CONDITIONS PART B - MATERIAL SPECIFICATIONS PART

More information

Coating Specifications

Coating Specifications Quadax Series Butterfly Valves Version May 2011 müller co-ax ag Gottfried-Müller-Str. 1 74670 Forchtenberg Germany Tel. +49 7947 828-0 Fax +49 7947 828-11 E-Mail info@co-ax.com Internet www.co-ax.com Table

More information

SECTION SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION

SECTION SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION SECTION 16-372 SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION 1. GENERAL SPECIFICATIONS The work of this Section includes furnishing all labor, equipment, materials (unless specifically identified as Owner-furnished)

More information

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered

More information

Product Index. Coating Thickness. Porosity. Adhesion. Inspection Kit. Surface Profile. Surface Cleanliness. Gloss

Product Index. Coating Thickness. Porosity. Adhesion. Inspection Kit. Surface Profile. Surface Cleanliness. Gloss Paint Test Equipment Price List 2018 Coating Thickness Wet Film Thickness Porosity Adhesion Surface Roughness Surface Cleanliness Climatic Conditions www.paint-test-equipment.com Product Index Coating

More information

Application Guidelines

Application Guidelines Technical Bulletin MANUFACTURER Raven Lining Systems 13105 E. 61 st Street, Suite A Broken Arrow, OK 74012 (918) 615-0020 DESCRIPTION Application Guidelines DESCRIPTION Raven Lining Systems offers several

More information

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770) Madewell Products Corporation December 2014 7561 Industrial Court Alpharetta, GA 30004 Office: (770) 475-8199 Fax: (770) 475-8167 Product Guide Specification SECTION 03935 RESTORATION MORTAR AND EPOXY

More information

SUPERIOR PRODUCTS INTERNATIONAL LEAD-BASED PAINT ABATEMENT ENCAPSULATION METHOD THAT ELIMINATES SANDBLASTING FOR STEEL STRUCTURES

SUPERIOR PRODUCTS INTERNATIONAL LEAD-BASED PAINT ABATEMENT ENCAPSULATION METHOD THAT ELIMINATES SANDBLASTING FOR STEEL STRUCTURES SUPERIOR PRODUCTS INTERNATIONAL INTRODUCES A LEAD-BASED PAINT ABATEMENT ENCAPSULATION METHOD THAT ELIMINATES SANDBLASTING FOR STEEL STRUCTURES Superior Products RUST GRIP and ENAMO GRIP Before 1 LEAD-BASED

More information

FLOW EFFICIENCY + CORROSION CONTROL AN ARGUMENT FOR INTERNAL PIPE COATINGS

FLOW EFFICIENCY + CORROSION CONTROL AN ARGUMENT FOR INTERNAL PIPE COATINGS FLOW EFFICIENCY + CORROSION CONTROL AN ARGUMENT FOR INTERNAL PIPE COATINGS The purpose of flow efficiency coatings How coatings affect pipeline pumping efficiency Flow efficiency coatings are meant to

More information

Motor Control Center Obsolescence

Motor Control Center Obsolescence International Conference Nuclear Energy for New Europe 2003 Portorož, Slovenia, September 8-11, 2003 http://www.drustvo-js.si/port2003 Motor Control Center Obsolescence Craig S. Irish Vice President, Sales

More information

FOR STEEL POTABLE WATER TANKS INTERIOR AND EXTERIOR CORROSION PROTECTION. Hydro-Zinc

FOR STEEL POTABLE WATER TANKS INTERIOR AND EXTERIOR CORROSION PROTECTION. Hydro-Zinc FOR STEEL POTABLE WATER TANKS INTERIOR AND EXTERIOR CORROSION PROTECTION Hydro-Zinc KEY BENEFITS TENACIOUS ADHESION EASY APPLICATION FAST CURE GALVANIC PROTECTION NSF/ANSI STD. 61 CERTIFIED LOW TEMPERATURE

More information

Extreme Weather Event Analysis & System Hardening Qualifications

Extreme Weather Event Analysis & System Hardening Qualifications Prepared by: Quanta Technology, LLC Contact: Carl L. Wilkins, P.E. cwilkins@quanta-technology.com 4020 Westchase Blvd., Suite 300 Raleigh, NC 27607 (919) 334-3092 office (919) 279-5848 cell Quanta Technology

More information

Wellhead Protection General Guidelines for New Private Domestic Wells

Wellhead Protection General Guidelines for New Private Domestic Wells Wellhead Protection General Guidelines for New Private Domestic Wells Key principles for wellhead protection for private domestic wells are as follows. Proper Location of Well (Proper sanitary control

More information

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested) Approved 28780 1,2 28780 acrylic ^(ValidationDate) 2 Product description This is a one component water borne acrylic emulsion coating. It is a versatile, fast drying product for exterior and interior use.

More information

Withlacoochee River Electric Cooperative, Inc. P.O. Box 278 Dade City, FL Billy E. Brown, Executive V.P.

Withlacoochee River Electric Cooperative, Inc. P.O. Box 278 Dade City, FL Billy E. Brown, Executive V.P. Wednesday, February 25, 2015 PSC 25 6.0343 Municipal Electric Utility and Rural Electric Cooperative Reporting Requirements Withlacoochee River Electric Cooperative, Inc. P.O. Box 278 Dade City, FL 33526-0278

More information

Information Document Protection System Information ID# R

Information Document Protection System Information ID# R Information Documents are for information purposes only and are intended to provide guidance. In the event of any discrepancy between the Information Document and the related authoritative document(s)

More information

Years of experience, customized for you.

Years of experience, customized for you. GE Energy Years of experience, customized for you. Industrial Maintenance and Repair Solutions Count on GE Energy Leading companies turn to us for industrial maintenance and repair services. Ours is a

More information

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation 5 pages DESCRIPTION PRINCIPAL CHARACTERISTICS COLOURS AND GLOSS BASIC DATA AT 20 C Mass density Volume solids VOC (supplied) Recommended dry film thickness Theoretical spreading rate Touch dry after Overcoating

More information

AMI information. for improved outage management

AMI information. for improved outage management Utilities the way we see it AMI information for improved outage management The information contained in this document is proprietary. 2013 Capgemini. All rights reserved. Rightshore is a trademark belonging

More information

PAINT SPECIFICATIONS WHO TO TALK TO AND WHAT OWNERS SHOULD EXPECT

PAINT SPECIFICATIONS WHO TO TALK TO AND WHAT OWNERS SHOULD EXPECT PAINT SPECIFICATIONS WHO TO TALK TO AND WHAT OWNERS SHOULD EXPECT You ve been running your current facility for six months. Everything is going smoothly but you know scheduled maintenance is coming up.

More information

Medium Voltage Service Maintenance and refurbishment

Medium Voltage Service Maintenance and refurbishment Medium Voltage Service Maintenance and refurbishment 2 Service maintenance and refurbishment Brochure Table of contents Maintenance strategies - Concepts...4 Preventative maintenance/testing...6 Preventative

More information

Section COATING RESTORATION

Section COATING RESTORATION Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80658R StoColor Texture - Coarse Textured Acrylic-Based,

More information

SP-100 Equipment Wash SP-110 Tool Cleaner

SP-100 Equipment Wash SP-110 Tool Cleaner DESCRIPTION: ADVANTAGES: USES: APPLICATION: SP-4888 Damp Surface Coating is a two-component epoxy coating developed specifically for application on wet or damp steel surfaces. In addition, it may be applied

More information

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F) DESCRIPTION One component heat resistant silicone topcoat for use in an elevated temperature coating system, primarily for application over PPG HI-TEMP 1027 primer PRINCIPAL CHARACTERISTICS Heat resistant

More information

Technical Data Jotamastic 80 MIO

Technical Data Jotamastic 80 MIO Technical Data Jotamastic 80 MIO Product description Jotamastic 80 MIO is a high solids two-pack micaceous iron oxide pigmented, surface-tolerant epoxy mastic coating which can be applied in low film thickness.

More information

U.S. General Services Administration Historic Preservation Technical Procedures. Galvanized Iron And Steel: Characteristics, Uses And Problems

U.S. General Services Administration Historic Preservation Technical Procedures. Galvanized Iron And Steel: Characteristics, Uses And Problems U.S. General Services Administration Historic Preservation Technical Procedures Galvanized Iron And Steel: Characteristics, Uses And Problems 05010-09 GALVANIZED IRON AND STEEL: CHARACTERISTICS, USES AND

More information

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing 221 Brooke Street Media, PA 19063 610-566-7470 Fax 610-891-0834 Website www.acrymax.com e-mail info@acrymax.com This document is intended to provide guidelines for the proper specification and application

More information

Contact Voltage at Toronto Hydro

Contact Voltage at Toronto Hydro Contact Voltage at Toronto Hydro Detection, Mitigation, Prevention Presented by: Ben La Pianta, P.Eng., MBA Vice President Distribution Grid Management 2009 Jodie Lane National Conference Stray Voltage

More information

AS/NZS :2014. Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings AS/NZS 2312.

AS/NZS :2014. Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings AS/NZS 2312. Australian/New Zealand Standard AS/NZS 2312.1:2014 Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings Part 1: Paint coatings Superseding AS/NZS

More information

Powering reliable solutions. for the commercial and industrial market

Powering reliable solutions. for the commercial and industrial market Powering reliable solutions for the commercial and industrial market We understand your challenges To maintain an uninterrupted operation, commercial and industrial users require the highest compliance

More information

Warranties for Architectural Metal Coatings: A Comparative Review

Warranties for Architectural Metal Coatings: A Comparative Review October 2009 Warranties for Architectural Metal Coatings: A Comparative Review For architects, specifiers, consultants and building owners, the only protection from these potential liabilities is a strong,

More information

Product Guide Specification

Product Guide Specification ALGRIP Manufactured by April 2017 104 North Maple Avenue P.O. Box 646 Leola, Pennsylvania 17540 Toll Free 800-345-8170 Fax 717-656-2041 Website www.algrip.com / www.rosstechnology.com E-mail sales@rosstechnology.com

More information

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C Approved 18420;18360 1,2 18420 epoxy ^(ValidationDate) 1 Product description This is a two component amine cured, glass flake reinforced, abrasion resistant epoxy coating. It is a surface tolerant, high

More information

The Application Guide offers product details and recommended practices for the use of the product.

The Application Guide offers product details and recommended practices for the use of the product. Technical Data Sheet Application Guide Approved 345 1,2 345 alkyd ^(ValidationDate) 1 Product description This is a one component styrene modified oxidatively drying alkyd coating. It is heat resistant

More information

Bridge Materials / structural plate. A polymer. Structural Corrugated Steel Bridges and tunnel liner. Economical

Bridge Materials / structural plate. A polymer. Structural Corrugated Steel Bridges and tunnel liner. Economical _ ARMTEC.COM Bridge Materials / structural plate STRATA-CAT PRODUCT GUIDE A polymer Coating System for Structural Corrugated Steel Bridges and tunnel liner Economical Durable Environmental Safety Superior

More information