Laser Ablation ICP-MS in Forensic Glass Analysis: A Decade of Experience

Size: px
Start display at page:

Download "Laser Ablation ICP-MS in Forensic Glass Analysis: A Decade of Experience"

Transcription

1 Session: New Developments and State of the Art in Trace Evidence Examinations Laser Ablation ICP-MS in Forensic Glass Analysis: A Decade of Experience Bundeskriminalamt Forensic Science Institute Germany KT13@bka.bund.de

2 1996 Trace Symposium San Antonio Wilfried Stoecklein The Forensic Analysis of Float Glass Characterization of Glasses from International Sources LA-ICP-MS in Forensic Glass Analysis

3 The Forensic Analysis of Float Glass Characterization of Glasses from International Sources W. Stoecklein, 1996 Elemental analysis of 61 glasses of global origin (28 Europe, 19 U.S.A., 14 Japan) (38 colorless, 21 green, 2 brown) (13 producers, 7 countries) Elemental analysis (ICP-MS, WDXRF) Determination of RI LA-ICP-MS in Forensic Glass Analysis

4 The Forensic Analysis of Float Glass Characterization of Glasses from International Sources W. Stoecklein, 1996 Liquid digestion: 0,5-2 mg of cleaned glass fragments (from bulk) + hydrofluoric acid, nitric acid, perfluoric acid Hot plate fuming to dryness Resolvation with 5 % nitric acid containing Rh int. std ICP-MS LA-ICP-MS in Forensic Glass Analysis

5 The Forensic Analysis of Float Glass Characterization of Glasses from International Sources Results 10 % of the examined glasses were indistinguishable by RI. Full differentiation of all glasses was possible by ICP-MS. Selection of elements which proved highest discrimination. Characterization of glass origin (Japan, U.S.A., Europe). LA-ICP-MS in Forensic Glass Analysis

6 The forensic Analysis of Float Glass Characterization of Glasses from International Sources Conclusion Quantitative analysis of 30 elements by ICP-MS improves evidential value of glass examination. LA-ICP-MS in Forensic Glass Analysis

7 Laser Laser Ablation carrier gas (He) Glass LA-ICP-MS in Forensic Glass Analysis:

8 Plasma ~7000 C carrier gas and sample MS Total destruction & ionisation of the sample

9 Why LA-ICP-MS? Measurements possible on small samples (~0,5 mm; ~ 0,02 in) No sample preparation (time saving) Quasi non-destructive analysis due to small sample uptake No problems measuring on rough surfaces (as in µ-xrf) Quantitative analysis of 20 major, minor and trace elements in one analytical run LA-ICP-MS in Forensic Glass Analysis:

10 History of instrumentation 1992 Installation of ICP-MS Fisions PQ Addition of UV-laser ablation system (1064 nm) 1997 Exchange of UV by Infrared laser ablation (266 nm) 2003 Replacement of old system with new LA-ICP-MS system (213 nm) LA-ICP-MS in Forensic Glass Analysis

11 ICP-MS Fisions PQ2+ IR-laser ablation VG Microprobe LA-ICP-MS in Forensic Glass Analysis:

12 ICP - MS LA LA-ICP-MS in Forensic Glass Analysis:

13 Why matrix matched standards? Until now SRM NIST 612 (50 ppm) is used for quantitative analysis of float glasses Better results by using a standard: with the same matrix (composition of main elements) with concentration of trace elements in the same range as typical float glass both are not given by NIST 612

14 R&D Project BKA - SCHOTT AG: Development of new calibration standards FGS 1 standard (low concentration) d = 9 cm h = 8 cm

15 R&D Project BKA - SCHOTT AG: Development of new calibration standards BKA-FGS 1: diameter: 10 mm thickness: 3 mm

16 NITECRIME activities on glass EU network project Main focus on float glass (highest forensic interest) Development of a protocol for glass analysis with LA-ICP-MS Evaluation of new calibration standards

17 NITECRIME activities on glass Workpackage 3.1 Instrumental validation ETH Zürich Two interlaboratory tests ( & 3.1.2) Workpackage 3.2 Glass BKA Two interlaboratory tests (3.2.1 & 3.2.2) Introduction of new matrix matchted standards (FGS 1 & 2) In total: Four interlaboratory tests dealing with glass Three interlaboratory tests with similar set-up

18 Instrument combinations: Laser Ablation Mass spectrometer 193 nm 213 nm 266 nm 266 nm high power Sector field ICP-MS Quadrupole ICP-MS

19 Participants of collaborative exercises Curtin University of Technology, Perth, Australia FBI, Quantico Florida International University, Miami ETH Zürich, Swiss Federal Institute of Technology NFI, Rijswijk, The Netherlands US Customs, Springfield BKA, Wiesbaden, Germany

20 NITE CRIME Summary 1/2 Similar quantitative results by labs with completely different LA-ICP-MS combinations (most RSD << 10 % intra-laboratory). Note: Results for float glass, not for std material! Note: Results for embedded glass, not for fragments! A protocol for optimised laser ablation conditions (as given in the fourth interlaboratory test) improved both the precision and the accuracy of quantitative results.

21 NITE CRIME Summary 2/2 The new matrix matched float glass standards FGS 1 and FGS 2 can be used as calibration or tuning standards for the quantitative analysis of float glass. Latkoczy, Becker et al. J. For. Sci. 2005; 50(6):

22 Reanalysis of the 63 float glasses of global origin by LA-ICP-MS Six replicate measurements App. 80 µm crater diameter Single shot Time resolved analysis 10 Hz, 10J/cm2 LA-ICP-MS in Forensic Glass Analysis:

23 Crater dimension: µm Smaller than a hair Nd:YAG-laser 213 nm

24 Variation of main & minor element concentration of 63 float glasses of global origin B o x - W h is k e r P lo t s f o r 6 3 f lo a t g la s s e s ; c o n c e n t r a t io n s m a in & m in o r e le m e n t s in µ g / g M e d ia n 25 % -75% 10 % -90% O u t lie r E x t r e m e v a lu e Na M g Al Si K Ca LA-ICP-MS in Forensic Glass Analysis:

25 Variation of trace element concentration of 63 float glasses of global origin B o x - W h is k e r P lo t s f o r 6 3 f lo a t g la s s e s ; c o n c e n t r a t io n s fo r t r a c e e le m e n t s in µ g / g , ,0 5 0,0 5,0 0,5 M e d ia n 25% -75% 10% -90% O u t lie r E x t r e m e v a lu e s Ti M n Sr Zr La Pb

26 Differentiation of origin by potassium and aluminum content Potassium (µg/g) 8000 E u ro p e U.S.A. Japan A lu m in u m ( µ g / g )

27 Differentiation of container glass from float glass Data set of 63 float glasses of global origin Data set of 20 container glasses of German origin

28 Differentiation of container glass from float glass Mn Ti Ca K flo a t c o n ta in e r g la s s e s flo a t c o n ta in e r g la s s e s 0 0 flo a t c o n ta in e r g la s s e s flo a t c o n ta in e r g la s s e s

29 Differentiation of container glass from float glass flo a t g la s s e s c o n t a in e r g l a s s e s Pb [ µg/ g] C a /M g

30 Analysis of small fragments sec Integration Time Counts per Second Fragment µg Time [sec] Time resolved analysis signal of Cerium from fragment 6

31 Analysis of small fragments sec Integration Time Counts per Second Fragment µg Time [sec] Time resolved analysis signal of Cerium from fragment 4

32 Analysis of small fragments sec Integration Time Counts per Second Fragment Time [sec] Time resolved analysis signal of Cerium from fragment 6

33 Findings 0,1-1,5 % lower RSD are achieved when excluding the results of the two measurements of fragment 3. Care should be taken when investigating very small and flat fragments, where only one or two shots are possible due to quantification problems with short TRA signals resulting in poorer reproducibilities.

34 Step by step approach in forensic glass analysis Glass case Physical examinations/ GRIM Chemical examinations (ICP-MS, SEM, XRF) samples distinguishable case report case report

35 Investigation of change of RI by LA interaction Side view mean RI (pre-ablation) = 1,51927 ± 3x10-5

36 FBI/BKA homogeneity study 2006 FBI laboratory bought commercial window pane FBI: GRIM, ICP-OES BKA: LA-ICP-MS measurements on 44 fragments from the same source

37 Flat Sheet Diagram Sheet 48 x48 Squares 4 x4-4 inch samples - 1 inch samples

38 Results of the homogeneity study RI analysis glass displays homogeneity The sheet does not show any trend in variation but varies as a whole within the expected range. ICP-OES analysis glass displays homogeneity There are no noticeable trends in the sheet. The error associated with the method is larger than the variation in the sheet.

39 Results of the homogeneity study LA-ICP-MS: RSD for the mean values of 44 samples 8% 6% 4% 2% Pb Hf Nd Ce La Ba Sn Zr Sr Rb Fe Mn Ti Ca K Al Mg Na Li 0% Analysis of variance significant influence of sample inhomogeneities on LA-ICP-MS results for several elements (Al, Zr, Hf, Pb) - due to the high spatial resolution of the method (sampling of 2 µg instead of mg) micro heterogeneity of the glass

40 Match criterion Glass fragments originating from different sources Glass fragments originating from the SAME source = Error Type I Error Type II =

41 Possible match criteria Hotellings T²-Test: requires more measurements than elements (i.e.20) impractical T-Test: often two fragments of the same glass can be discriminated too many Type I errors N-sigma criteria: best choice for our application

42 Optimization of the match criterion Amount of errors type I and type II in dependence on n and m 1000 I Fehler Error2. Art type II Number of errors Fehler Error1. Art type Match criteria (n-sigma & m "allowed" elements)

43 Optimised Match Criterion 4-sigma criterion 0 element may be distinguishable FBI-Glass: 44 data sets, 946 pairwise comparisons Type I errors: 10 (1,06 %) 05_Stat: 63 data sets, 1953 pairwise comparisons Type II errors: 3 (0,15 %) =

44 Summary Introduction of matrix matched std FGS 1 & 2 NITE CRIME activity: LA-ICP-MS produces accurate data for the comparison of float glasses (protocol) FBI/BKA glass project (micro homogeneity & type I error) Reanalyses of 63 float glasses of global origin (type II errors) Optimized match criterion: 4-sigma criterion Further validation led to ISO accreditation of LA-ICP-MS method in May 2007 Routine application in casework

45 Thanks Thanks to Maureen Bottrell, Jodi Webb & Robert Koons (FBI). Special thanks to Dr. Peter Weis, Marc Dücking, Peter Watzke/BKA. Thanks to all NITECRIME members for their support, especially: J. Almirall, FIU, U.S.A. J. Buscaglia, R. Koons, FBI Academy, U.S.A. D. Günther, C. Latkoczy, ETH Zürich, Switzerland S. Montero, G. van der Peijl, NFI, Netherlands J. Watling, Curtin University, Perth Australia, V. Zdanowicz, U.S. Customs, U.S.A.

THE DIFFERENTIATION OF FLOAT GLASS USING REFRACTIVE INDEX AND ELEMENTAL ANALYSIS: COMPARISONS OF TECHNIQUES

THE DIFFERENTIATION OF FLOAT GLASS USING REFRACTIVE INDEX AND ELEMENTAL ANALYSIS: COMPARISONS OF TECHNIQUES THE DIFFERENTIATION OF FLOAT GLASS USING REFRACTIVE INDEX AND ELEMENTAL ANALYSIS: COMPARISONS OF TECHNIQUES Stefan BECKER 1, Lawrence GUNARATNAM 2, Tacha HICKS 3, Wilfried STOECKLEIN 1, Geoff WARMAN 4

More information

STUDY OF ELEMENT FINGERPRINTING IN GOLD DORÉ BY GLOW DISCHARGE MASS SPECTROMETRY

STUDY OF ELEMENT FINGERPRINTING IN GOLD DORÉ BY GLOW DISCHARGE MASS SPECTROMETRY STUDY OF ELEMENT FINGERPRINTING IN GOLD DORÉ BY GLOW DISCHARGE MASS SPECTROMETRY MICHAEL W. HINDS, Ph.D. 1 ELEMENT FINGERPRINTING In 1994, John Whatling* used laser ablation inductively coupled mass spectrometry

More information

Laser Ablation ICP-MS

Laser Ablation ICP-MS LASER ABLATION 1 Laser Ablation ICP-MS CETAC LSX 500 www.cetac.com www.thermo.com Thermo Finnigan Element 2 Gold can be melted and recast and is therefore virtually untraceable 3 DISTINGUISH GOLD SAMPLES

More information

XRF DRIFT MONITORS DATA CALIBRATION MATERIAL

XRF DRIFT MONITORS DATA CALIBRATION MATERIAL UNIQUE PRODUCTS FROM ONE SOURCE XRF DRIFT MONITORS DATA CALIBRATION MATERIAL KEY FEATURES Monitor Composition The monitors are manufactured as stable fortified glass discs that are used to correct for

More information

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com CERTIFICATE OF ANALYSIS tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 ACCREDITATION / REGISTRATION

More information

Mean 206 Pb/ 238 U age = 26.2 ± 0.6 (2 ) (n = 13, MSWD = 2.8) Pb/ 235 U

Mean 206 Pb/ 238 U age = 26.2 ± 0.6 (2 ) (n = 13, MSWD = 2.8) Pb/ 235 U .8.6 T16 Mean age = 26.2 ±.6 (2 ) (n = 13, MSWD = 2.8)..1.2.3.4.5 7.5 ET23 24.3 12 16 8.1 4 Mean age = 17. ±.5 (2 ) (n =, MSWD = 3.66)..8.12.16..24. 7.5 ET25C 24.3 12 16 8.1 4 Mean age = 15. ±.4 (2 ) (n

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis First issued: June 2018 Version: June 2018 REE-3 Certified Reference Material for an Ore with Rare Earth Elements and Zirconium Table 1 REE-3 Certified Values note: Please refer

More information

ElvaX ProSpector in Exploration & Mining

ElvaX ProSpector in Exploration & Mining ElvaX ProSpector in Exploration & Mining Introduction ElvaX ProSpector is a fast, accurate and easy tool for different mining applications. It provides onsite analysis of ore samples with minimal sample

More information

Certificate of Analysis

Certificate of Analysis Brammer Standard Company, Inc. Certificate of Analysis BS 625A Certified Reference Material for Inconel 625 - UNS Number N06625 1 Certified Estimate of Certified Estimate of 2 3 2 Value Uncertainty Value

More information

Evidence of Performance regarding the requirements for float glass according to EN 572

Evidence of Performance regarding the requirements for float glass according to EN 572 Evidence of Performance regarding the requirements for float glass according to EN 572 Test Report 605 32401 Client Noval Glass Industrial Group (China) Co., Ltd. Noval Glass Industiral Zone Qingdao, 523965

More information

SECTIOn 4. Claritas PPT Multi-Element Standards for ICP-MS

SECTIOn 4. Claritas PPT Multi-Element Standards for ICP-MS SECTIOn 4 Claritas PPT Multi-Element Standards for ICP-MS Your Science is Our Passion. Claritas PPT Multi-Element Standards for ICP-MS The great precision, sensitivity, and rapid analysis of multi-element

More information

Assaying and Analysis Choices in Practice

Assaying and Analysis Choices in Practice Assaying and Analysis Choices in Practice Au assays at the GDL laboratories Dirk Hofmans Umicore UPMR Hoboken, Belgium March 2015 Agenda LBMA Good delivery rules for laboratories How to assay > 995 Gold?

More information

Wavelength Dispersive XRF Spectrometer

Wavelength Dispersive XRF Spectrometer ISO9001 ISO14001 for Wafers, Media Disks, and Large Samples Wavelength Dispersive XRF Spectrometer ADVANCED XRF For Large and Irregularly Shaped Samples Is there any solution to analyze a large sample

More information

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com CERTIFICATE OF ANALYSIS tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 ACCREDITATION / REGISTRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 WESTMORELAND MECHANICAL TESTING & RESEARCH, INC. 221 Westmoreland Drive Youngstown, PA 15696 Michael Self Phone: 724 537 3131 E-mail: mself@wmtr.com CHEMICAL

More information

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo James Hannan, Applications Chemist, Thermo Fisher Scientific, Cambridge, UK Application Note 43171 Key Words Environmental, EU, waste,

More information

Certificate of Analysis

Certificate of Analysis Brammer Standard Company, Inc. Certificate of Analysis BS 800 Certified Reference Material for Incoloy 800 - UNS Number N08800 1 Certified Estimate of Certified Estimate of 2 3 2 Value Uncertainty Value

More information

Appendix 11. Report by Becker et al on the BKA preliminary testing of the CIP entitled: analysis round robin.

Appendix 11. Report by Becker et al on the BKA preliminary testing of the CIP entitled: analysis round robin. Appendix 11. Report by Becker et al on the BKA preliminary testing of the CIP entitled: analysis round robin. Report on the analysis of PGM-bearing samples N1, N2, and N3 S. Becker KT 13 Forensic Science

More information

Gallium Arsenide monocrystalline

Gallium Arsenide monocrystalline Gallium Arsenide CMK manufacture Semi-insulating and Semiconducting Gallium Arsenide wafers and ingots by LEC (Liquid Encapsulated Czochralsky) or VGF (Vertical Gradient Freeze) growth method. Required

More information

Direct Analysis of Photoresist by ICP-MS. Featuring the Agilent Technologies 7500s ICP-MS

Direct Analysis of Photoresist by ICP-MS. Featuring the Agilent Technologies 7500s ICP-MS Direct Analysis of Photoresist by ICP-MS Featuring the Agilent Technologies 7500s ICP-MS 1 Presentation Outline How is photoresist used? Analytical challenges Instrumentation developments Analytical approach

More information

Application Note PlasmaQuant PQ 9000 Elite. Analysis of Rare Earth Elements in Granite and Sandstone by HR ICP-OES. Challenge.

Application Note PlasmaQuant PQ 9000 Elite. Analysis of Rare Earth Elements in Granite and Sandstone by HR ICP-OES. Challenge. Application Note PlasmaQuant PQ 9000 Elite Analysis of Rare Earth Elements in Granite and Sandstone by HR ICP-OES Challenge Quantification of Rare Earth Elements in line-rich geological materials, such

More information

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009 SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009 SCP SCIENCE 21800 Clark Graham Baie d'urfe, Quebec H9X 4B6 CANADA David Smith Phone: 514 457 0701 dsmith@scpscience.com REFERENCE MATERIAL PRODUCER Valid To:

More information

Standard Solutions (Traceable to NIST)

Standard Solutions (Traceable to NIST) Standard Solutions (Traceable to NIST) - Multi Element ICP Standard Solutions (Inductively Coupled Plasma Spectroscopy) - Single Element ICP Standard Solutions (Inductively Coupled Plasma Spectroscopy)

More information

Standard Solutions (Traceable to NIST)

Standard Solutions (Traceable to NIST) Standard Solutions (Traceable to NIST) - Multi Element ICP Standard Solutions (Inductively Coupled Plasma Spectroscopy) - Single Element ICP Standard Solutions (Inductively Coupled Plasma Spectroscopy)

More information

Increased Sample Throughput for ICP-OES Applied to U.S. EPA Method 200.7

Increased Sample Throughput for ICP-OES Applied to U.S. EPA Method 200.7 application Note Inductively Coupled Plasma Optical Emission Spectroscopy Authors Laura Thompson Zoe Grosser, Ph.D. Paul Krampitz PerkinElmer, Inc. Shelton, CT 06484 USA Increased Sample Throughput for

More information

Aerosol and Rainfall Sampling and Analysis for GEOTRACES

Aerosol and Rainfall Sampling and Analysis for GEOTRACES Aerosol and Rainfall Sampling and Analysis for GEOTRACES Bill Landing Department of Oceanography Florida State University Tallahassee, FL 32306-4320 850-644-6037 wlanding@fsu.edu NSF/OCE funding to acquire

More information

Advanced Materials Analysis with Micro-XRF for SEM

Advanced Materials Analysis with Micro-XRF for SEM Advanced Materials Analysis with Micro-XRF for SEM Birgit Hansen, Application Scientist EDS and Micro-XRF for SEM Stephan Boehm, Product Manager Micro-XRF for SEM Bruker Nano GmbH, Berlin, Germany Innovation

More information

Evaluation of methods for analysis of lead in air particulates: An intra-laboratory and interlaboratory

Evaluation of methods for analysis of lead in air particulates: An intra-laboratory and interlaboratory Evaluation of methods for analysis of lead in air particulates: An intra-laboratory and interlaboratory comparison Frank X. Weber, James M. Harrington, Andrea McWilliams, Keith E. Levine Trace Inorganics

More information

The Determination of Alloying Elements in High-Carbon Steel using Radially Viewed Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES)

The Determination of Alloying Elements in High-Carbon Steel using Radially Viewed Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) Application Note - AN1504 The Determination of Alloying Elements in High-Carbon Steel using Radially Viewed Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) Introduction Page 1 Carbon

More information

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES Marine Beauvir, Application Specialist, Thermo Fisher Scientific, Cambridge, UK Application Note 43161 Key Words High throughput,

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis First issued: September 2010 Version: September 2010 GTS-2a Certified Reference Material for a Gold Ore Mill Tailings Table 1 GTS-2a Certified Values Within-lab Between-labs 95%

More information

EU water analysis using the Thermo Scientific icap 7400 ICP-OES Duo

EU water analysis using the Thermo Scientific icap 7400 ICP-OES Duo APPLICATION NOTE 43171 EU water analysis using the Thermo Scientific icap 7400 ICP-OES Duo Authors Introduction James Hannan, Application Specialist, Thermo Fisher Scientific, Hemel Hempstead, UK Within

More information

Table I: MCL and MRL Concentrations for Contaminants Monitored Under the Safe Drinking Water Act National Primary Drinking Water Regulations

Table I: MCL and MRL Concentrations for Contaminants Monitored Under the Safe Drinking Water Act National Primary Drinking Water Regulations Application Note - AN1303 Water Analysis Following U.S. EPA Method 200.7 Using the Teledyne Leeman Lab s Prodigy7 ICP-OES Under the Safe Drinking Water Act (SDWA) and the Clean Water Act (CWA), the USEPA

More information

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode Analysis of steel and its alloys using the GB/T 20125-2006 standard and an Agilent 5100 ICP-OES in dual view mode Application note Metals analysis and production Authors John Cauduro Agilent Technologies

More information

Determination of Elemental Impurities in Graphite-based Anodes using the Agilent 5110 ICP-OES

Determination of Elemental Impurities in Graphite-based Anodes using the Agilent 5110 ICP-OES Application Note Material testing and research Determination of Elemental Impurities in Graphite-based Anodes using the Agilent 5110 ICP-OES Accurate determination for lithium battery anodes Authors Ni

More information

Expanded Coating Analysis Performance for electroless Ni Plating and Bath Analysis with Micro-XRF

Expanded Coating Analysis Performance for electroless Ni Plating and Bath Analysis with Micro-XRF Expanded Coating Analysis Performance for electroless Ni Plating and Bath Analysis with Micro-XRF Bruker Nano Analytics, Berlin, Germany Webinar, December 05, 2018 Innovation with Integrity Presenters

More information

Standard Operation Procedure. Analysis of Major, Minor and Trace Elements in Soil and Sediment Samples with ICP-OES and ICP-MS

Standard Operation Procedure. Analysis of Major, Minor and Trace Elements in Soil and Sediment Samples with ICP-OES and ICP-MS Standard Operation Procedure Analysis of Major, Minor and Trace Elements in Soil and Sediment Samples with ICP-OES and ICP-MS Soil & Plant Analysis Laboratory University of Wisconsin Madison http://uwlab.soils.wisc.edu

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis First issued: February 2011 Version: June 2011 WMG-1a Certified Reference Material for a Mineralized Gabbro with Gold and Platinum Group Elements Element Units Mean Table 1 WMG-1a

More information

An Evaluation of Portable X-Ray Fluorescence for Artifact Sourcing in the Field: Can a Handheld Device Differentiate Anatolian Obsidian Sources?

An Evaluation of Portable X-Ray Fluorescence for Artifact Sourcing in the Field: Can a Handheld Device Differentiate Anatolian Obsidian Sources? An Evaluation of Portable X-Ray Fluorescence for Artifact Sourcing in the Field: Can a Handheld Device Differentiate Anatolian Obsidian Sources? Ellery Frahm Departments of Anthropology and Geology & Geophysics

More information

Certificate of Analysis First issued: May 2008 Version: May 2008

Certificate of Analysis First issued: May 2008 Version: May 2008 Certificate of Analysis First issued: May 2008 Version: May 2008 DS-1 Certified Reference Material for a Gold Ore Table 1 DS-1 Certified Values Within-lab Betweenlabs 95% Confidence Interval of Mean Ag

More information

Stable isotope ratio measurements using the Finnigan NEPTUNE multicollector ICP-MS. Claudia Bouman Thermo Electron (Bremen)

Stable isotope ratio measurements using the Finnigan NEPTUNE multicollector ICP-MS. Claudia Bouman Thermo Electron (Bremen) Stable isotope ratio measurements using the Finnigan NEPTUNE multicollector ICP-MS Claudia Bouman Thermo Electron (Bremen) The NEPTUNE Introduced 2000 2 Multicollection vs. Single collection magnet magnet

More information

S2 RANGER LE: Analysis of Light Elements in Cement, Slags and Feldspar

S2 RANGER LE: Analysis of Light Elements in Cement, Slags and Feldspar S2 RANGER LE: Analysis of Light Elements in Cement, Slags and Feldspar 1 Welcome Today s topics: S2 RANGER LE o o o Overview XFlash LE detector Improved X-ray tube Analysis of Light Elements in Cement

More information

Certificate of Analysis BS 110B

Certificate of Analysis BS 110B Brammer Standard Company, Inc. Certificate of Analysis BS 110B 1 Certified Reference Material for Grade 11000 Electronic Tough Pitch Copper (UNS Number C11000) Certified Estimate of Certified Estimate

More information

SCOPE OF ACCREDITATION TO ISO 17034:2016

SCOPE OF ACCREDITATION TO ISO 17034:2016 SCOPE OF ACCREDITATION TO ISO 17034:2016 SCP SCIENCE 21800 Clark Graham Baie d'urfe, Quebec H9X 4B6 CANADA David Smith Phone: 514 457 0701 dsmith@scpscience.com REFERENCE MATERIAL PRODUCER Valid To: November

More information

- Particulate matter (PM10, 2.5, 1) -Coarse region (2.5µm < dp <10µm)

- Particulate matter (PM10, 2.5, 1) -Coarse region (2.5µm < dp <10µm) - Particulate matter (PM10, 2.5, 1) The Suspension of fine solids particles or liquid droplets or mixture of them in the gas or liquid -Coarse region (2.5µm < dp

More information

Chapter 1.6. Polished Single-Crystal Silicon, Prime Wafers (all numbers nominal) Wafer Specification Table. Diameter 100 mm 4-inch 150 mm 6-inch

Chapter 1.6. Polished Single-Crystal Silicon, Prime Wafers (all numbers nominal) Wafer Specification Table. Diameter 100 mm 4-inch 150 mm 6-inch Chapter 1.6 I - Substrate Specifications Polished Single-Crystal Silicon, Prime Wafers (all numbers nominal) Wafer Specification Table Diameter 100 mm 4-inch 150 mm 6-inch Thickness 525 µm 20.5 mils 675

More information

Multi-Element Analysis of Trace Metals in Animal Feed using ICP-OES

Multi-Element Analysis of Trace Metals in Animal Feed using ICP-OES Application Note Food and Agriculture Multi-Element Analysis of Trace Metals in Animal Feed using ICP-OES A fast, simple, and low cost method, using an Agilent 5110 VDV ICP-OES, suitable for high throughput

More information

Sorting and Drying Code Price Unit. Sorting and Boxing of Samples, received as pulps SORTBOX 0.00 Sample

Sorting and Drying Code Price Unit. Sorting and Boxing of Samples, received as pulps SORTBOX 0.00 Sample Sample Preparation Sorting and Drying Sorting and Boxing of Samples, received as pulps SORTBOX 0.00 Sample Sorting and Drying of Samples, prior to preparation SORTDRY 0.00 Sample Reporting of Sample Weight,

More information

Automating EPA 6020 Compliant Analysis with the Agilent 7900 ICP-MS and ESI prepfast Autodilution System

Automating EPA 6020 Compliant Analysis with the Agilent 7900 ICP-MS and ESI prepfast Autodilution System Automating EPA 6020 Compliant Analysis with the Agilent 7900 ICP-MS and ESI prepfast Autodilution System Application Note Environmental Authors Austin Schultz and Jake Unnerstall, Elemental Scientific,

More information

Appendix C Geochemical Data Robert J. Speakman and Michael D. Glascock

Appendix C Geochemical Data Robert J. Speakman and Michael D. Glascock Appendix C Geochemical Data Robert J. Speakman and Michael D. Glascock Sherds and clay test tiles were sawed intro three pieces using a water-cooled, diamond-coated slow speed saw blade. One piece from

More information

Analysis of Heavy Metals in Iron-based Fertilizers by HR ICP-OES

Analysis of Heavy Metals in Iron-based Fertilizers by HR ICP-OES Analysis of Heavy Metals in Iron-based Fertilizers by HR ICP-OES Abstract The analysis of Iron-rich samples by ICP-OES is often very demanding since prominent Iron-based spectral interferences affect many

More information

Ultra-fast ICP-OES determinations of base metals in geochemical samples using next generation sample introduction technology

Ultra-fast ICP-OES determinations of base metals in geochemical samples using next generation sample introduction technology Ultra-fast ICP-OES determinations of base metals in geochemical samples using next generation sample introduction technology Application note Geochemistry, mining and metals Author John Cauduro Agilent

More information

Determination of Elemental Bad Actors (As, Hg and Si) in Petrochemical Samples Using ICP-AES and ICP-MS

Determination of Elemental Bad Actors (As, Hg and Si) in Petrochemical Samples Using ICP-AES and ICP-MS Determination of Elemental Bad Actors (As, Hg and Si) in Petrochemical Samples Using ICP-AES and ICP-MS Robert I. Botto ExxonMobil Refining and Supply Analytical Services Laboratory Baytown, Texas Crude

More information

Determination of trace and ultratrace elements by ICP-SFMS

Determination of trace and ultratrace elements by ICP-SFMS Determination of trace and ultratrace elements by ICP-SFMS Ilia Rodushkin, Emma Engström, Douglas Baxter ALS Scandinavia AB Luleå University of Technology 1 Luleå laboratory Part of ALS group (>300 laboratories

More information

Amplifying ICPMS Productivity Using Discrete Sampling Technology

Amplifying ICPMS Productivity Using Discrete Sampling Technology Amplifying ICPMS Productivity Using Discrete Sampling Technology Continuing the discussion on high throughput ICP-MS Steve Wilbur Agilent Technologies March 26, 2009 Previously, in Tripling the Productivity

More information

Report of STSM under COST Action FP1301: EuroCoppice PHYTOREMEDIATION POTENTIAL OF DIFFERENT POPLAR CLONE COPPICE PLANTATION

Report of STSM under COST Action FP1301: EuroCoppice PHYTOREMEDIATION POTENTIAL OF DIFFERENT POPLAR CLONE COPPICE PLANTATION Report of STSM under COST Action FP131: EuroCoppice PHYTOREMEDIATION POTENTIAL OF DIFFERENT POPLAR CLONE COPPICE PLANTATION Lauma Buša, Mag.chem., researcher Home institution: University of Latvia, Faculty

More information

ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems

ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems PAPPLICATION R O D U C T NNOTE O T E ICP-OES and ICP-MS SC-FAST Benefits Increases sample throughput 2-3 times Minimizes sample uptake and rinse-out time Eliminates contact with peristaltic pump tubing

More information

Thickness and composition analysis of thin film samples using FP method by XRF analysis

Thickness and composition analysis of thin film samples using FP method by XRF analysis Technical articles Thickness and composition analysis of thin film samples using FP method by XRF analysis Hikari Takahara* 1. Introduction X-ray fluorescence spectroscopy (XRF) is an elemental quantification

More information

The image part with relationship ID rid4 was not found in the file. Welcome

The image part with relationship ID rid4 was not found in the file. Welcome The image part with relationship ID rid4 was not found in the file. Welcome Trace Metals Analysis: Impurity Determinations By Thomas Kozikowski Chemist, R&D at Inorganic Ventures Key Considerations What

More information

Characterization of Surface Metals on Silicon Wafers by SME-ICP-MS. Featuring the Agilent Technologies 7500s ICP-MS

Characterization of Surface Metals on Silicon Wafers by SME-ICP-MS. Featuring the Agilent Technologies 7500s ICP-MS Characterization of Surface Metals on Silicon Wafers by SME-ICP-MS Featuring the Agilent Technologies 7500s ICP-MS 1 Presentation Outline Why is Surface Metal Extraction ICP-MS important? Technique Wafer

More information

VHG Labs. Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE

VHG Labs. Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE VHG Labs Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE Committed To Our Customers Our Mission Statement: VHG Labs provides superior value to our customers

More information

Core Analysis with the Tracer

Core Analysis with the Tracer BRUKER ELEMENTAL Core Analysis with the Tracer Prepared by: Lee Drake, Senior Application Scientist January 23, 2014 BRUKER ELEMENTAL Key Points OBJECTIVE 3 EXPLORATION 3 DECISION MAKING 3 RECLAMATION

More information

Analysis of 14 Trace Elements in Stainless Steel

Analysis of 14 Trace Elements in Stainless Steel ICP OPTICAL ATOMIC EMISSION SPECTROSCOPY Analysis of 14 Trace Elements in Stainless Steel Joël Sire, Daniel Legain Serma Technologie France Keywords: metallurgy 1 Introduction This Application Note describes

More information

Li Mass = 7 amu Melting point C Density 0.53 g/cm 3 Color: silvery

Li Mass = 7 amu Melting point C Density 0.53 g/cm 3 Color: silvery Blackline Master B02: Mendeleev s Element Cards H Mass = 1 amu Melting point -259 0 C Density 0.0909 g/cm 3 Color: colorless Li Mass = 7 amu Melting point 180.5 0 C Density 0.53 g/cm 3 Be Mass = 9 amu

More information

Reduction of the Sample Size in the Analysis of Rock by EDXRF

Reduction of the Sample Size in the Analysis of Rock by EDXRF Copyright (C) JCPDS International Centre for Diffraction Data 1999 873 Reduction of the Sample Size in the Analysis of Rock by EDXRF Riidiger Harmel, Ulrike Otto, Olaf Haupt, Clemens Sch$er and Walter

More information

Identification of Headlight and Windshield glass of Car

Identification of Headlight and Windshield glass of Car Abstract Research Journal of Recent Sciences ISSN 2277-2502 Identification of Headlight and Windshield glass of Car Theogene Ntakirutimana 1 and Asha Rajiv 2 1 Department of Forensics, School of Graduate

More information

Analysis of inhomogeneous samples and trace element detection in alloys using QUANTAX Micro-XRF on SEM

Analysis of inhomogeneous samples and trace element detection in alloys using QUANTAX Micro-XRF on SEM Analysis of inhomogeneous samples and trace element detection in alloys using QUANTAX Micro-XRF on SEM Bruker Nano Analytics, Berlin, Germany Webinar, June 02, 2016 Innovation with Integrity Presenters

More information

Analysis of wear metals and contaminants in engine oils using the 4100 MP-AES

Analysis of wear metals and contaminants in engine oils using the 4100 MP-AES Analysis of wear metals and contaminants in engine oils using the 4100 MP-AES Application note Energy and fuels Authors Phil Lowenstern and Elizabeth Reisman Agilent Technologies Melbourne, Australia Introduction

More information

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo APPLICATION NOTE 43157 US EPA Method 200.7 using the Thermo Scientific icap 7600 ICP-OES Duo Authors Introduction James Hannan, Application Specialist, Thermo Fisher Scientific, Hemel Hempstead, UK In

More information

STEVEN SHIELDKRET WM MN SAMPLES * Final 05/08/09 19/08/09 12 SPECIAL SAMPLE #01 5M SHOW AT SURFACE TP 11. Graeme Farrant Laboratory Manager

STEVEN SHIELDKRET WM MN SAMPLES * Final 05/08/09 19/08/09 12 SPECIAL SAMPLE #01 5M SHOW AT SURFACE TP 11. Graeme Farrant Laboratory Manager STEVEN SHIELDKRET Narra Nickel Mining & Development Corporation 705 The Linden Suites San Miguel Ave, Ortigas Center Pasig City, PHILLIPINES Lab Ref Cost Code Status Received WM118396 Final 05/08/09 Samples

More information

Examination of Analytical Conditions for Trace Elements Based on the Detection Limit of EPMA (WDS)

Examination of Analytical Conditions for Trace Elements Based on the Detection Limit of EPMA (WDS) Examination of Analytical Conditions for Trace Elements ased on the Detection Limit of EPMA () Ayako Sato, Norihisa Mori, Masaru Takakura and Satoshi Notoya Electron Optics Division, JEOL Ltd. Introduction

More information

State-of-the-art Flame Synthesis of Nanoparticles

State-of-the-art Flame Synthesis of Nanoparticles Verbrennung und chemisch reaktive Prozesse in der Energie- und Materialtechnik State-of-the-art Flame Synthesis of Nanoparticles Dr. Frank Ernst ernst@ptl.mavt.ethz.ch 200 nm Particle Technology Laboratory,

More information

Layer Thickness Analysis of Thin Metal Coatings with. Bruker Nano Analytics, Berlin, Germany Webinar, June 8 th 2017

Layer Thickness Analysis of Thin Metal Coatings with. Bruker Nano Analytics, Berlin, Germany Webinar, June 8 th 2017 Layer Thickness Analysis of Thin Metal Coatings with micro-xrf on SEM Bruker Nano Analytics, Berlin, Germany Webinar, June 8 th 2017 09.06.2017 Presenters Stephan Boehm Product Manager Micro-XRF/SEM Bruker

More information

SIMPLIFIED MATERIALS ANALYSIS VIA XRF. Ravi Yellepeddi and Didier Bonvin Thermo Fisher Scientific (Ecublens) SARL, Ecublens/Switzerland

SIMPLIFIED MATERIALS ANALYSIS VIA XRF. Ravi Yellepeddi and Didier Bonvin Thermo Fisher Scientific (Ecublens) SARL, Ecublens/Switzerland SIMPLIFIED MATERIALS ANALYSIS VIA XRF Ravi Yellepeddi and Didier Bonvin Thermo Fisher Scientific (Ecublens) SARL, Ecublens/Switzerland SIMPLIFIED MATERIALS ANALYSIS VIA XRF Ravi Yellepeddi and Didier Bonvin

More information

Analysis of Pharmaceuticals by ICP-MS and WDXRF

Analysis of Pharmaceuticals by ICP-MS and WDXRF Analysis of Pharmaceuticals by ICP-MS and WDXRF Frank X. Weber, James M. Harrington, Andrea McWilliams, James Medlin, Keith E. Levine Trace Inorganics Department, RTI International, Research Triangle Park,

More information

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer Water Analysis Using ICP-OES with an Ultrasonic Nebulizer Application Note Inductively Coupled Plasma-Optical Emission Spectrometers Author Tran T. Nham Introduction Water quality has always been a primary

More information

Radial, Axial or Dual View ICP: Which Do You Choose? Manny Almeida Teledyne Leeman Labs, Inc. Hudson, NH

Radial, Axial or Dual View ICP: Which Do You Choose? Manny Almeida Teledyne Leeman Labs, Inc. Hudson, NH Radial, Axial or Dual View ICP: Which Do You Choose? Manny Almeida Teledyne Leeman Labs, Inc. Hudson, NH 03031 Manuel.Almeida@Teledyne.com Teledyne Leeman Labs, Inc. US based manufacturer of Elemental

More information

LABS & TECHNOLOGICAL SERVICES AGQ S L CTRA A-423 KM24.3 BURGUILLOS (SEVILLA) SPAIN Testing Laboratory TL-475 (Revised September 14, 2015)

LABS & TECHNOLOGICAL SERVICES AGQ S L CTRA A-423 KM24.3 BURGUILLOS (SEVILLA) SPAIN Testing Laboratory TL-475 (Revised September 14, 2015) This is to signify that LABS & TECHNOLOGICAL SERVICES AGQ S L CTRA A-423 KM24.3 BURGUILLOS (SEVILLA) 41220 SPAIN Testing Laboratory TL-475 has met the requirements of the IAS Accreditation Criteria for

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Metals and Minerals Division 2 Perry Road Witham Essex CM8 3TU Contact: Mrs C Hargreaves Tel: +44 (0)1376 536800 Fax: +44 (0)1376 520819 E-Mail:

More information

Impact of New ICH Q3D and USP <232> Guidelines for Elemental Impurities Analyses

Impact of New ICH Q3D and USP <232> Guidelines for Elemental Impurities Analyses Impact of New ICH Q3D and USP Guidelines for Elemental Impurities Analyses Content Background... 2 Why should the amounts of elemental impurities be controlled in drug products?... 2 Regulatory requirements...

More information

Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES Application Note - AN1704 Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES John Condon, Applications Chemist and Bruce MacAllister, Applications

More information

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry Prodigy ICP Application Note: # 1046 Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry Introduction Stainless steels are a corrosion resistant family of iron alloys that

More information

Analysis of inorganic impurities in lubricating oils by ICP-MS

Analysis of inorganic impurities in lubricating oils by ICP-MS Analysis of inorganic impurities in lubricating oils by ICP-MS Application note Authors Energy and Fuels Junichi Takahashi, Kei Kasahara Agilent Technologies, Japan Introduction The most widely used techniques

More information

Certificate of Analysis First issued: March 2008 Version: March 2008

Certificate of Analysis First issued: March 2008 Version: March 2008 Certificate of Analysis First issued: March 2008 Version: March 2008 CPB-2 Certified Reference Material for Lead Concentrate Table 1 CPB-2 Certified Values Within-lab Betweenlabs 95% Confidence Interval

More information

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS in cooperation with the WG Aluminium of the Committee of Chemists of GDMB CERTIFICATE OF ANALYSIS ERM -EB312a AlMgSi0,5 Certified value 1) Uncertainty 2) Element Mass fraction in % Si 0.403 0.008 Fe 0.198

More information

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry Application Note - AN1505 Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry Introduction Page 1 Stainless steels are a corrosion resistant family of iron alloys that have

More information

Extending the Capability of Portable XRF Smarter, Smaller and Faster GALM 2016

Extending the Capability of Portable XRF Smarter, Smaller and Faster GALM 2016 Extending the Capability of Portable XRF Smarter, Smaller and Faster GALM 2016 Chris Calam, Regional Sales Manager, EMEA Portable Analytical Instruments chris.calam@thermofisher.com The world leader in

More information

ATI FLAT ROLLED PRODUCTS Brackenridge, PA for technical competence in the field of

ATI FLAT ROLLED PRODUCTS Brackenridge, PA for technical competence in the field of A2LA has accredited Brackenridge, PA for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005

More information

Environment Agency. The determination of metals in solid environmental samples (2006) Methods for the Examination of Waters and Associated Materials

Environment Agency. The determination of metals in solid environmental samples (2006) Methods for the Examination of Waters and Associated Materials Environment Agency The determination of metals in solid environmental samples (2006) Methods for the Examination of Waters and Associated Materials 2 The determination of metals in solid environmental

More information

Determination of 22 Elements Following US EPA Guidelines with a New Megapixel CCD ICP-OES

Determination of 22 Elements Following US EPA Guidelines with a New Megapixel CCD ICP-OES Determination of 22 Elements Following US EPA Guidelines with a New Megapixel CCD ICP-OES Application Note Inductively Coupled Plasma-Optical Emission Spectrometers Author Ingrid Szikla Introduction Elemental

More information

Composition Analysis of Animal Feed by HR ICP-OES

Composition Analysis of Animal Feed by HR ICP-OES Composition Analysis of Animal Feed by HR ICP-OES Abstract The High-Resolution Array ICP-OES equipped with Standard-Kit was used for the analysis of Al, B, Ca, Co, Cr, Cu, Fe, I, K, Na, Mn, Mg, Mo, Ni,

More information

Analysis of Toxic Trace Elements in Coffee Bean Products by HR ICP-OES

Analysis of Toxic Trace Elements in Coffee Bean Products by HR ICP-OES Analysis of Toxic Trace Elements in Coffee Bean Products by HR ICP-OES Abstract Samples of coffee powder and caffeine extracts from a coffee bean processor were submitted to the analysis of As, Cd, Cr,

More information

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo US EPA Method 200.7 using the Thermo Scientific icap 7600 ICP-OES Duo James Hannan, Applications Chemist, Thermo Fisher Scientific, Cambridge, UK Application Note 43157 Key Words Environmental analysis,

More information

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ 1 History of Technology Leadership in Atomic Spectroscopy 62 AAS instruments manufactured

More information

Natural-Colored Chrome Chalcedony Identified Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS)

Natural-Colored Chrome Chalcedony Identified Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) Natural-Colored Chrome Chalcedony Identified Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) Andy Shen GIA Laboratory, Carlsbad Recently, Mr. Shun-Tien Ten Wu of Taiwan sent

More information

PROCUREMENT PROCEDURE OF CPRI (NON WORKS) Dt of Revision : Issue Dt. :

PROCUREMENT PROCEDURE OF CPRI (NON WORKS) Dt of Revision : Issue Dt. : Revision No. : 03 Page 1 of 14 1 Place where equipment to be supplied 2 Scope (Supply, Supply & Installation/Supply, Installation & Training) DMD, CPRI, Bengaluru Supply, Installation, commissioning and

More information

Comparison of Off-peak vs. MAN vs. Nth Point background measurements John Donovan,

Comparison of Off-peak vs. MAN vs. Nth Point background measurements John Donovan, Comparison of vs. vs. background measurements John Donovan, 09-03-2009 Comparison of methods The following is an attempt to compare three methods (, and ) for background determination using both a homogeneous

More information

Results of Proficiency Test Catalyst May 2001

Results of Proficiency Test Catalyst May 2001 Results of Proficiency Test Catalyst May 21 Organised by: Dordrecht, the Netherlands Author: ing. M. Audier Correctors: dr. R.G. Visser & ing. R. Coppoolse Report: iis1z1 June 21 CONTENTS 1 INTRODUCTION...

More information

Certificate of Analysis First issued: March 2010 Version: March 2010

Certificate of Analysis First issued: March 2010 Version: March 2010 Certificate of Analysis First issued: March 2010 Version: March 2010 RTS-3a Certified Reference Material for a Sulphide Ore Mill Tailings Element Units Mean Table 1 RTS-3a Certified Values Within-lab Betweenlabs

More information

X-ray Fluorescence Spectrometry X-ray Fluorescence Spectrometry (XRF) is a non-destructive, quantitative technique for determining chemical

X-ray Fluorescence Spectrometry X-ray Fluorescence Spectrometry (XRF) is a non-destructive, quantitative technique for determining chemical X-ray Fluorescence Spectrometry X-ray Fluorescence Spectrometry (XRF) is a non-destructive, quantitative technique for determining chemical composition. When a primary x-ray collides with an atom in the

More information