10/27/2010. Laboratory ID: Jeanne M. Hugo Dow Chemical Company Industrial Hygiene Laboratory, 1803 Building, Midland, MI 48674
|
|
- Preston Short
- 5 years ago
- Views:
Transcription
1 10/27/2010 Laboratory ID: Jeanne M. Hugo Dow Chemical Company Industrial Hygiene Laboratory, 1803 Building, Midland, MI Dear Jeanne M. Hugo: Congratulations! The AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC s Analytical Accreditation Board (AAB) has approved Dow Chemical Company as an accredited Industrial Hygiene laboratory. Enclosed, please find the IHLAP accreditation certificate, scope of accreditation document and a copy of the current AIHA-LAP, LLC license agreement (if your completed agreement is not on file at AIHA-LAP, LLC). The accreditation logo has been designed for use by all AIHA-LAP, LLC accredited laboratories. If your laboratory chooses to use the logo in its advertising the laboratory s accreditation, you must complete and return the AIHA- LAP, LLC license agreement to a Laboratory Accreditation Specialist. Once submitted, an electronic copy of the accreditation logo will be sent to you. Please inform us if your laboratory does not wish to use the logo in advertising. Laboratory accreditation shall be maintained by continued compliance with IHLAP requirements (see Policy Modules 2B and 6B), which includes proficient participation in the IHPAT programs for all Fields of Testing (FoTs) for which the laboratory is accredited. An accredited laboratory that wishes to expand into a new FoT must submit an updated accreditation application to AIHA-LAP, LLC for review by the AAB. Any changes in ownership, laboratory location, personnel, FoTs/s, or significant procedural changes shall be reported to AIHA-LAP, LLC in writing within twenty (20) business days of the change. The accreditation certificate is the property of AIHA-LAP, LLC and must be returned to us should your laboratory withdraw or be removed from the IHLAP. Again, congratulations. If you have any questions, please contact Edmund Wong, Laboratory Accreditation Specialist, at (703) Sincerely, Cheryl O. Morton Director, AIHA Affiliate Laboratory Programs Enclosure
2
3 AIHA Laboratory Accreditation Programs, LLC SCOPE OF ACCREDITATION Dow Chemical Company Laboratory ID: Industrial Hygiene Laboratory, 1803 Building, Midland, MI Issue Date: 11/01/2010 The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory s current accreditation status for the particular field(s) of testing/s, since these can change due to proficiency status, suspension and/or revocation. A complete listing of currently accredited Industrial Hygiene laboratories is available on the AIHA-LAP, LLC website at: Industrial Hygiene Laboratory Accreditation Program (IHLAP) Initial Accreditation Date: 01/01/1976 IHLAP Scope Gas 3M TDB #1028 3M TDB #128 GMD 10 GMD 111 GMD 116 GMD 117 Description or Analyte Diisobutylketone Tetrachloroethylene Dicyclopentadiene, Ethylidene-2-norborene, 5-, Vinyl 2-norborene, 5-, Vinylcyclohexane DETDA Difluoroethoxypyrimidine (DEEP), Dichloro-2- ethoxypyrimidine, 4,6- Dichloro-2- Trichloromethylpyridine, 3,6-, Dichloro-2- Trichloromethylpyridine, 5,6-, Dichloro-5- Trichloromethylpyridine, 2,3-, Methylpyridine, 2-, Methylpyridine, 3-, Tetrachloro-6- Trichloromethylpyridine, 2,3,4,5-, Trichloro-2- Trichloromethylpyridine, 2,4,5-, Trichloro-5- Trichloromethylpyridine, 2,3,6- Page 1 of 10
4 Gas GMD 131 Description Dichlorobenzonitrile, 3,4-, Diflurobenzonitrile, 3,4-, Dimethyl-2- imidazolidinone, 1,3- GMD 144 Dichloropropane, 1,2- Diisopropanolamine, GMD 167 Monoisopropanolamine, Triisopropanolamine GMD 174 GMD 204 GMD 217 GMD 22 GMD 223 GMD 234 GMD 238 GMD 243 GMD 258 GMD 259 GMD 265 GMD 290 GMD 293 GMD 297 Dimethylformamide Dowanol EPH Methylchloroacetate Acrolein Epichlorohydrin, Propylene oxide Butyl Acetate, n-, Ethyl Acetate, Isoamyl Acetate, Isobutyl Acetate, Isopropyl Acetate, n-propyl Acetate Carbon Tetrachloride, Ethyl Benzene, vinyl-1- cyclohexene, 4-, Vinylcyclohexane, Vinylidene chloride Ethyl Chloroacetate Ethylene Dichloride, trichloroethane, 1,1,2-, trichloroethane, 1,1,1-, Dichloroethane, Vinyl Chloride, Vinylidene Chloride Ethylene Oxide Ethylhexanal, 2-, Isobutyraldeyde, methylbutyraldehyde, propionaldehyde Heptane Hexachlorobenzene, Hexachlorobutadiene, Hexachloroethane, Carbon Tetrachloride Hexane Page 2 of 10
5 Gas GMD 3 GMD 309 GMD 34 GMD 353 GMD 356 GMD 369 GMD 434 GMD 44 GMD 47 GMD 470 GMD 496 GMD 499 GMD 52 GMD 520 GMD 526 GMD 543 GMD 546 GMD 560 GMD 564 GMD 570 GMD 580 GMD 585 GMD 589 Description Allyl Methacrylate, butyl acrylate, ethylhexyl acrylate, 2-, isobutyl acrylate, methyl acrylate, methyl methacrylate, ethyl acrylate Isobutane Allyl Chloride Xylene, p-, Methyl Ethyl Ketone, Toluene Methyl Iodide Methylene Chloride Phenol Benzene Benzene, chloroform, dioxane, 1,4-, toluene, trichloroethylene, xylenes, Carbon Tetrachloride Toluene, Methanol Garlon 4, Triclopyr 2- Butoxyethyl Ester Garlon EE (Triclopyr Ethyl Ester) Biphenyl, DPO, 3-ethyl biphenyl, 4-ethyl biphenyl, Diphenyl oxide Vinyltoluene, Divinylbenzene Styrene, Toluene, Ethyl Benzene Acrylonitrile, styrene Diphenyl oxide, Biphenyl Butyl Propionate, pentyl propionate Hydroxyethylacrylate, 2-hyroxypropyl acrylate Vinyl Chloride Butyl Ethanolamine, t-, diethyl ethanolamine, diisopropyl ethanolamine, dimethyl ethanolamine Acetic Acid Vinylbenzyl Chloride Page 3 of 10
6 Gas GMD 590 GMD 594 GMD 597 GMD 60 GMD 601 GMD 610 Description Dibromo-3- chloropropane, 1,2- Ethyl Benzene, perchloroethylene, xylenes Vinyl Trimethoxysilane Bromoform, cyanogen bromide, dibromoacetonitrile Cyclopentane, Bromopropane, 1-, Propyl bromide, Isopropyl Chloride cyanocyclohexene, heptane, acrylonitrile Dimethylsulfoxide GMD 619 GMD 62 Butadiene, 1,3- GMD 620 Telone II (Dichloropropene, 1,3-) GMD 622 formylcyclohexanecarbo nitrile Isooctane, GMD 626 Tetrahydrofuran, Isopar C GMD 627 Lutidine, 3, 5- GMD 630 GMD 631 GMD 632 GMD 635 GMD 636 GMD 64 Acrylonitrile Ethyl vinyl ether Dimethyl Ether Bromodifluoroethane MOD/MOE Butane, n-, Freon 11, Pentane, Chlorodifluroethane (Freon 142), Ethyl Chloride GMD 644 Tetrachloroethane, 1,1,1,2- GMD 645 Myclobutanil, Myclobutinal GMD 647 Diiodomethane GMD 656 difluoroethane, tetrafluoroethane GMD 663 CS-1246, P-1487 GMD 665 Dowtherm Q GMD 670 Ethylhexanoic acid, 2- Page 4 of 10
7 Gas Description or Analyte GMD 677 Octane, n- GMD 682 Proglyde DMM Di-nitro-ortho-secbutylphenol GMD 684 GMD 685 Benzocyclobutene GMD 689 Isopropanol, Propanol, 2- GMD 691 VTMOS, OTMOS GMD 7 MMP 2-(2-Metnoxyethoxy) ethanol, 2-(2- Propoxyetnoxy)-Ethanol, Diethylene Glycol Butyl GMD 72 Ether, Diethylene Glycol Butyl Ether Acetate, Diethylene Glycol Monoethyl Ether, Butoxyethanol, 2-, Butoxyethyl acetate, 2-, Ethoxyethyl Acetate, 2-, GMD 75 Ethylene Glycol n-hexyl Ether, 2-Methoxylethanol Acetate, Cellosolve Acetate GMD 79 Butylene Oxide, 1,2- Chlorobenezene, p- GMD 80 dichlorobenzene Dichlorobenzene, p-, Dichlorobenzene, o-, GMD 81 Trichlorobenzene, 1, 3, 5-, Chlorobenzene GMD 81 Chlorobenzene Acetone, chloroform, GMD 83 isopropanol, tetrahydrofuran Chloromethyl Methyl GMD 86 Ether Chlorophenol, o, m, & p, 2,4-dichlorophenol, 2,6- dicholorophenol, pentachlorophenol, GMD 87 tetrachlorophenol, 2,3,4,5-, trichlorophenol, 2,3,5-, trichlorophenol, 2,4,6-, trichlorophenol, 3,4,5- Page 5 of 10
8 Gas GMD 89 GMD 90 GMD 91 GMD 92 GMD 93 GMD 95 GMD 97 IHAL40989 NIOSH 1003 NIOSH 1014 NIOSH 1019 NIOSH 1022 NIOSH 1300 NIOSH 1302 NIOSH 1400 NIOSH 1401 NIOSH 1402 NIOSH 1450 NIOSH 1457 NIOSH 1501 NIOSH 1550 NIOSH 1606 NIOSH 2000 NIOSH 2002 NIOSH 2004 NIOSH 2005 NIOSH 2528 NIOSH 2555 NIOSH 5004 NIOSH 5517 NIOSH 5518 OSHA 100 OSHA 103 OSHA 104 OSHA 35 OSHA 65 OSHA 66 OSHA 71 OSHA 91 Description Chloropicrin Chloroprene Chlorpyrifos Chlorpyrifos-methyl Cis-1,4-dichloro-2- butene, dichloro-1- butene, 3,4-, trns, 1,4- dichloro-2-butene Gamma Cyhalothrin Page 6 of 10
9 Gas OSHA 93 OSHA PV2025 OSHA PV2041 OSHA PV2085 OSHA PV2091 OSHA PV2108 OSHA PV2138 3M TDB #1028 Description Acetone, Cyclohexane, Tricloroethylene, 1,1,2-, Cumene, Vinylidene chloride, Propylene oxide, Acetonitrile, Methyl acrylate, Ethanol, Cyclohexanone, Heptane, Diisobutyl ketone, n-butanol, Isobutanol, n-propanol, Vinylidene Chloride GC- Diffusive Sampler 3M TDB #119 Toluene Isopropanol, Propanol, 3M TDB # M TDB #123 Trichloroethane, 1,1,1- Perchloroethylene, 3M TDB #128 Tetrachloroethylene 3M TDB #133 Butadiene, 1,3- Methylene Chloride, Assay TDB Vinyl Chloride, Butadiene, 1,3- Assay Tech TDB Benzene, Toluene Butly Acrylate, 1-butanol, 2-butoxyethanol, butyl GMD 2 acrylate, 2-ethylhexyl acrylate, methyl ethyl ketone, toluene, vinyl acetate n-amyl acetate, n-butyl acetate, ethyl acetate, isoamyl acetate, GMD 233 isobutyl acetate, isopropyl acetate, methyl acetate, n- propyl acetate Page 7 of 10
10 GC- Diffusive Sampler GMD 248 GMD 28 GMD 29 GMD 320 GMD 372 GMD 46 GMD 53 Description Ethyl Benzene, 0-xylene, m-xylene, p-xylene Acrylonitrile Styrene, Acrylonitrile, Vinyl acetate, Butyl Acrylate, 2-ethylhexyl acrylate, Ethyl Acrylate, Methyl methacrylate, Benzene, Ethyl Benzene Isoprene Chloroform, Methylene Chloride; Carbon Tetrachloride Benzene Diphenyl oxide, Biphenyl, 3- ethylbiphenyl, 4- ethylbiphenyl Tetrachloroethylene GMD 59 GMD 625 Dichloroethane, 1,2- Dichloroethane, 1,2-, Methyl acrylate, GMD 63 Styrene, Vinyl Chloride, Vinylidene chloride, Xylene GMD 633 GMD 637 GMD 66 GMD 680 GMD 74 1,2-dichloropropane MOD/MOE 1-Butene, Hexane, Tetrahydrofuran, Isopentane Proglyde DMM 2-Butoxyethanol, 2- butoxyethyl acetate, 2- ethoxyethanol, 2- ethoxyethyl acetate, ethylene glycol n-hexyl ether, 2-methoxyethanol acetate, 2-methoxyethanol, Cellosolve Acetate Liquid GMD 110 DE-498, Flumetsulam Page 8 of 10
11 Liquid GMD 114 GMD 130 GMD 133 GMD 139 GMD 25 GMD 335 GMD 432 GMD 436 GMD 437 GMD 587 GMD 603 GMD 605 GMD 617 GMD 624 GMD 652 GMD 657 GMD 660 GMD 662 GMD 664 GMD 691 HEH38187 Modified NIOSH 2540 Modified OSHA 42 NIOSH 5004 NIOSH 5029 OSHA 42 OSHA 47 OSHA 64 OSHA 87 OSHA 107 OSHA PV2034 Description Dibromo-3- nitrilopropionamide; 2,2- Dichlorobenzonitrile, 2,6-, Difluoroaniline, 2,6- Dichlorophenol, 2,4-, Dichlorophenoxyacetic acid,2,4- Dichlorophenoxyacetic acid,2,4- Acrylamide, Acrylic Acid Methylacrylic Acid Phenol, Bisphenol-A Picloram Piperazine Hydroquinone Formaldehyde ADI monomer, ADI trimer 1,3- and 1,4- cyclohexanedimethamine Bis(aminomethyl)cyclohexane AEEA Chloroacetyl chloride Amical BIT OIT CMIT, MIT Octyltrimethoxysilane, Vinyltrimethoxysilane Maneb / Mancozeb isophorone diisocyannate Page 9 of 10
12 Description Miscellaneous Gravimetric Mod NIOSH 0500 Mod NIOSH 0600 The laboratory participates in the following AIHA-LAP, LLC-approved proficiency testing programs: AIHA-PAT Programs, LLC IHPAT Metals AIHA-PAT Programs, LLC IHPAT Organic Solvents AIHA-PAT Programs, LLC IHPAT Silica AIHA-PAT Programs, LLC IHPAT Diffusive Sampler (3M) AIHA-PAT Programs, LLC IHPAT Diffusive Sampler (SKC) AIHA-PAT Programs, LLC IHPAT Diffusive Sampler (AT) AIHA-PAT Programs, LLC IHPAT Asbestos AIHA-PAT Programs, LLC Bulk Asbestos (BAPAT) AIHA-PAT Programs, LLC Beryllium (BePAT) HSE Workplace Analytical Scheme for Proficiency (WASP) (Formaldehyde) HSE Workplace Analytical Scheme for Proficiency (WASP) (Thermal Desorption Tubes) Pharmaceutical Round Robin Compressed/Breathing Air Round Robin National Voluntary Laboratory Accreditation Program (NVLAP - determined at the time of site assessment) New York State Department of Health (NYS DOH PCM and TEM) ERA Air and Emissions standards for indoor air quality Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (IFA, formerly BGIA) Institut de Recherche Robert-Sauvé en Santé et en Sécurité du Travail (IRSST) Page 10 of 10
DIVISION OF WASTE MANAGEMENT RESIDENTIAL VAPOR INTRUSION SCREENING CONCENTRATIONS (March, 2016)
Note: The Residential screening level below or site specific screening concentrations (utilizing site specific attenuation and exposure factors) can be used. In either case the site s remedy must include
More informationGround Water Screening Level (GWSL) 1,2 ug/l TCR = 1.0E-05/HQ =0.2. Sub-slab and Exterior Soil Gas Screening Level (SGSL) 1,2.
Note: The non-residential screening level below or site specific screening concentrations (utilizing site specific attenuation and exposure factors) can be used. In either case the site s remedy must include
More informationAppendix F: Hazardous Gases and Vapors
Appendix F: Hazardous Gases and Vapors The following pages contain excerpts from the National Fire Protection Association (NFPA) publication NFPA 497M Classification of Gases, Vapors, and Dusts for Electrical
More informationOREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation RJ Lee Group, Inc./Columbia Basin Analytical Laboratories
MATRIX Reference Code Analyte Code Description Air EPA TO-11A 10311805 Determination of Formaldehyde in Ambient Air Using Adsorbent Cartridge Followed by High Performance Liquid Chromatography (HPLC) 6110
More informationAppendix A Analytical Methods for Air Sampling
Analytical s Air Sampling Acenaphthene TO-13A PUF / XAD 10 0.4 Acenaphthylene TO-13A PUF / XAD 10 0.35 Acetaldehyde Acetone TO-15 Can or Bag 1.9 0.47 Acetonitrile TO-15 Can or Bag 1.7 0.12 Acetophenone
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationTable 1 Pre-set response factors. Compound Code RF. n-butyl acetate nbutacet 2.2. n-butyl acrylate nbutacry 1.8. carbon disulfide CS2 1.
TECHNICAL NOTE 2020ComboPRO Response Factors Table 1 Pre-set response factors Compound Code RF acetaldehyde ACETAL 6.6 acetone ACETONE 1.2 acrolein (2-propenal) 2 ACROLEIN 3.3 allyl chloride (3-chloro-1-propene)
More informationSOLVENT PROPERTIES Typical Physical Properties of More than 120 Commonly Used Organic Solvents
SOLVENT PROPERTIES Typical Physical Properties of More than 20 Commonly Used Organic Solvents TECH DOC Nexeo Solutions is a leading distributor of solvents manufactured by the top suppliers across North
More informationCarcinogens. lb/yr. lb/day
15A NCAC 02Q.0711 EMISSION RATES REQUIRING A PERMIT (a) A permit to emit toxic air pollutants shall be required for any facility where one or more emission release points are obstructed or non-vertically
More informationTexas Commission on Environmental Quality
These fields of accreditation supercede all previous fields. The urges customers to Matrix: Air & Emissions Method 40 CFR Part 50 Appendix B Total Suspended Particulate TX 3973 10000304 Method 40 CFR Part
More informationDate Issued: July 01, 2017 Expiration Date: June 30, 2018
State of Florida Department of Health, Bureau of Public Health Laboratories This is to certify that MAXXAM ANALYTICS - MICHIGAN 22345 ROETHEL DRIVE NOVI, MI 48375 has complied with Florida Administrative
More informationOREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation
MATRIX Reference Code Analyte Code Description STAT Analysis Corporation 40 CFR Part 50 Appendix J Environmental Laboratory Program 3950 Particulates
More informationObstructed or Non-Vertical Oriented Toxic Air Pollutant Permitting Emission Rates (TPER) Toxicants
15A NCAC 02Q.0711 EMISSION RATES REQUIRING A PERMIT (a) A permit to emit toxic air pollutants shall be required for any facility, excluding sources exempt from evaluation by 15A NCAC 02Q.0702, if one or
More informationSUBJECT DATE PAGE Item No Mineral EPA 13B. EPA 13A Chlorinated Hydrocarbons EPA TO-14A EPA TO-15 EPA TO-17 EPA TO-14A EPA TO-15
Approved Methods: Air and Emissions 03/30/2018 1 of 19 Autonomous Detection Systems Biological Critical Agents 99 NYSDOH Approved Method 9900 Chemical Critical Agents 99 NYSDOH Approved Method 9900 Radioactive
More informationDetector Tube Selection Guide. March, 2013 (Rev. Q)
Detector Selection Guide March, 2013 (Rev. Q) www.sensidyne.com Table of Contents Page Detector s... 4 12 Compressed Breathing s... 13 Ion s... 13 TWA s... 13 Numerical Listing... 14-16 Kits and Accessories...
More information15A NCAC 02B.0269 is amended with changes without notice pursuant to G.S. 150B-21.5(a)(3) as follows: SECTION.0600 RIPARIAN BUFFER RESTORATION FUND
1 8 9 10 11 1 1 1 1 1 1 18 19 0 1 8 9 0 1 1A NCAC 0B.09 is amended with changes without notice pursuant to G.S. 10B-1.(a)() as follows: SECTION.000 RIPARIAN BUFFER RESTORATION FUND 1A NCAC 0B.09 1A NCAC
More informationDetector Tube Selection Guide. March, 2011 (Rev. Q)
Detector Tube Selection Guide March, 2011 (Rev. Q) www.sensidyne.com Page Detector Tubes... 4 12 Compressed Breathing Tubes... 13 Ion Tubes... 13 TWA Tubes... 13 Numerical Tube Listing... 14-16 Kits and
More informationDate Issued: July 01, 2018 Expiration Date: June 30, 2019
State of Florida Department of Health, Bureau of Public Health Laboratories This is to certify that EMSL ANALYTICAL, INC - CINNAMINSON 200 ROUTE 130 NORTH CINNAMINSON, NJ 08077 has complied with Florida
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ENVIRONMENTAL CONSERVATION LABORATORIES JACKSONVILLE 4810 Executive Park Court, Suite 111 Jacksonville, FL 32216 Lori S. Mangrum Phone: 904 296 3007 Email address:
More informationThermal Desorption Technical Support
Thermal Desorption Technical Support Note 79: Air monitoring - the respective advantages and applications of canisters and tubes Key Words: Environmental, Air toxics, Canisters, On-line sampling Introduction
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Environmental Conservation Laboratories -
More informationTrade Waste Approved Acceptance Criteria
Trade Waste Approved Acceptance Criteria Trade waste discharged from land, at the point where it is sampled, must comply with the standards set out in this Schedule. 1. PHYSICAL CHARACTERISTICS 1.1. Temperature
More informationAmy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1
Application Note US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1 Abstract US EPA Method 8260 in conjunction
More informationUS EPA Method 8260 With the Tekmar Lumin and the Agilent 7890B GC/5977A MS
Application Note US EPA Method 8260 With the Tekmar Lumin and the Agilent 7890B GC/5977A MS Author Roger Bardsley Applications Chemist, Teledyne Tekmar Abstract US EPA Method 8260 is used primarily by
More informationSCOTT Method TO-14A/15/17
SCOTT Method TO-14A/15/17 Calibration Standards Benefits and Features SCOTT technical expertise in engineering Method 14A/15/17, HAPS and TIC calibration standards, sulfur mixes and vapor intrusion products
More informationUS EPA Method 8260 with the Atomx XYZ and the Thermo Scientific TRACE 1310 GC and ISQ MS
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1803 P+T VOC ENV US EPA Method 8260 with the Atomx XYZ and the Thermo Scientific TRACE 1310 GC and ISQ MS Amy Nutter, Applications Chemist; Teledyne Tekmar Page
More informationTSB-1 TSB-3 TSB-2. Legend. Approximate Site Limits. Soil Boring Location. Feet. Figure 2 Boring Location Map
TSB-1 TSB-3 TSB-2 Legend 0 150 300 450 600 Feet East of Calhoun Road & South of Griggs Road Houston, Harris County, Texas TGE Project No.: R10114.01 6120 West by Northwest Blvd. Suite 100 Houston, Texas
More informationApproved Acceptance Criteria for discharge to the sewerage system
Approved Acceptance Criteria for discharge to the sewerage system Contents 1 Physical characteristics......2 1.1 Temperature...2 1.2 Solids...2 1.3 Oils, fats and grease...2 1.4 Organic liquids...2 1.5
More informationIndustry Standards & Definitions
NEMA Designation Underwriters Laboratories Inc. UL 50 and UL 508 Canadian Standards Association CSA Standard C22.2 No 94 404 90 ADALET NEMA Designation Underwriters Laboratories Inc. UL 50 and UL 508 Canadian
More informationAgain, congratulations. If you have any questions, please contact Drake McGregor, Laboratory Accreditation Specialist, at (703)
August 31, 2017 Laboratory ID: 151772 Marisa Meador Envirocheck, Inc. 2211 West Orangewood Avenue Orange, CA 92868 Dear Ms. Meador: Congratulations! The AIHA Laboratory Accreditation Programs (AIHA-LAP),
More informationSensidyne Detector Tube Selection Guide
Tubes for over 00 gases & vapors Sensidyne Tube Selection Guide effective April, 00 Page Short-Term Tubes... Tubes... TWA Tubes... Compressed Breathing Air Tubes... Numerical Tube Listing...5 HOW TO USE
More informationOntario Soil Standards (other than sediment) II (mg/kg) Potable Ground Water Non-Potable Ground Water. Industrial/ Commercial
T3 Table 3 Soil quality benchmarks I Substance Ontario Soil Standards (other than sediment) II (mg/kg) Potable Ground Water Non-Potable Ground Water Canadian Environmental Quality Criteria and Guidelines
More informationDEPARTMENT OF THE AIR FORCE PACIFIC AIR FORCES
DEPARTMENT OF THE AIR FORCE PACIFIC AIR FORCES 10 February 2014 MEMORANDUM FOR RECORD FROM: 18 AMDS/SGPB SUBJECT: Amelia Earhart Intermediate and Bob Hope Primary School s Air/Soil Sample Results 1. Background:
More informationAutumnwood Investigation The Community s Perspective
Autumnwood Investigation The Community s Perspective Concerned Neighbors of Wildomar Center for Community Action and Environmental Justice (CCAEJ) September 19, 2014 Penny J. Newman Floyd Villanueva Xonia
More informationDraft Guidance on Vapor Intrusion into Buildings from Groundwater and Soil under the Act 2 Statewide Health Standard Vapor Intrusion Subcommittee
Draft Guidance on Vapor Intrusion into Buildings from Groundwater and Soil under the Act 2 Statewide Health Standard Vapor Intrusion Subcommittee Cleanup Standards Scientific Advisory Board Meeting July
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Pace Analytical Services, LLC. 150 N 9 th Street Billings, MT 59101 Emily Agola Phone: (616) 656-2257 Emily.Agola@pacelabs.com ENVIRONMENTAL Valid To: May 31,
More information2012 Air Toxics Summary
2012 Air Toxics Summary New Jersey Department of Environmental Protection INTRODUCTION Air pollutants can be divided into two categories: the criteria pollutants (ozone, sulfur dioxide, carbon monoxide,
More information2017 Air Toxics Summary
2017 Air Toxics Summary New Jersey Department of Environmental Protection INTRODUCTION Air pollutants can be generally divided into two categories: criteria pollutants (ozone, sulfur dioxide, carbon monoxide,
More informationTECH SERVICES DOCUMENT (Rev 6/12/2008) Page 1 of 6
Page 1 of 6 3607-78-1 1,1,1,3,3,3-Hexachloropropane 71-55-6 1,1,1-Trichloroethane 107-06-2 1,2-Dichloroethane 78-87-5 1,2 Dichloropropane 73 3.2 107-21-1 1,2-Dihydroxyethane
More informationEnviroMail TM 05 Canada
EnviroMail TM 05 Canada BRITISH COLUMBIA CONTAMINATED SITES REGULATION (BC CSR) OMNIBUS UPDATE Key Topics Covered in this Enviromail: Searching and Accessing the latest information on Stage 11 BC CSR Omnibus
More informationNorth Carolina Cleanup Standards for Hydrocarbon Contaminated Groundwater
North Carolina Cleanup Standards for Hydrocarbon Contaminated Groundwater The North Carolina Department of Environment and Natural Resources has adopted Risk-Based Assessment and Corrective Action procedures
More informationState Regulations (Part 360) Landfill setting Monitoring activities Results Potential Impacts
State Regulations (Part 360) Landfill setting Monitoring activities Results Potential Impacts Environmental monitoring is just one of many landfill activities regulated by the state, including Permit application
More informationTHE RIGHT GLOVE FOR THE JOB SM
THE RIGHT GLOE FOR THE JOB SM PERMEATION & DEGRADATION TEST DATA Provided data and recommendations are intended as guides only. Work practices and conditions vary and are beyond our control. It is impossible
More informationCorrections to Static Book. Page 18 figure 2-5: delete acetone from figure (I can t do this electronically)
Corrections to Static Book Page 18 figure 2-5: delete acetone from figure (I can t do this electronically) Page 41 Note 1 ninth line: delete second period after Figure 2-6.5 Page 43 Section 2-6.6: replace
More informationIH Scan Packages Novi Laboratory
IH Scan Packages Novi Laboratory SCANS ACIDS, INORGANIC (5) OSHA ID-165SG / ID-174SG Hydrogen Bromide Sulfuric Acid Silica Gel Tube, washed SKC 226-10-03 or ORBO 53 Hydrogen Chloride Phosphoric Acid Nitric
More informationSENSOR SELECTION GUIDE
SENSOR SELECTION GUIDE TOXIC AND COMBUSTIBLE GAS MONITORS (Includes gas listings with TLV-TWA, STEL, IDLH, LEL, and UEL for most gases) INTERNATIONAL SENSOR TECHNOLOGY The Leader In Gas Detection Since
More informationMUNICIPAL DRINKING WATER PRODUCED BY DORVAL DRINKING WATER TREATMENT PLANT 2016
CONCENTRATION MIN. AVE. MAX. Physical Properties ph (units) 6.5-8.5 6.5-8.5 7.10 7.25 7.50 Turbidity (N.T.U.) 1.0 5 / 1 2 0.16 0.27 0.54 Biological Characteristics ANNUAL AVERAGE Total coliforms (PRE-ABS
More informationSelecting Provisional Toxicity Values in the Absence of IRIS Values and Implication for Emerging Contaminants
Selecting Provisional Toxicity Values in the Absence of IRIS Values and Implication for Emerging Contaminants Anita K. Meyer DABT US Army Corps of Engineers Hazardous, Toxic and Radioactive Center of Expertise
More informationAnatek Labs, Inc - Spokane Spokane, WA
Anatek Labs, Inc - Spokane Spokane, WA has complied with provisions set forth in Chapter 173-50 WAC and is hereby recognized by the Department of Ecology as an ACCREDITED LABORATORY for the analytical
More informationThermal Desorption Technical Support Note 87: A cryogen-free method for monitoring trace greenhouse gases in air. Key Words:
Thermal Desorption Technical Support Note 87: A cryogen-free method for monitoring trace greenhouse gases in air Key Words: Trace greenhouse gases, Kyoto Protocol, CFCs, HCFCs, UNITY 2, CIA 8, air toxics,
More informationMaterial Description 1,1,1-Trichloroethane 1,2,4-Trichlorobenzene 1,4-Butanediol 1,4-Dioxane 1-Butene 1-Pentene 100% Sulfur 100% Sulfuric Acid
1,1,1-Trichloroethane 1,2,4-Trichlorobenzene 1,4-Butanediol 1,4-Dioxane 1-Butene 1-Pentene 100% Sulfur 100% Sulfuric Acid 2,4-Dichlorophenol 2-Butene 3/4-inch Medium Density Fiberboard 3/4-inch Particleboard
More informationVolatile Organic Compounds in Solids PBM
Lab Manual Section Revision Date: Mar 15, 2016 Volatile Organic Compounds in Solids PBM Parameter Analytical Method Introduction Method Summary MDL(s) and EMS Analyte Codes Volatile Organic Compounds (VOCs)
More informationMcAllister Point Landfill Operation and Maintenance. Naval Station Newport, Rhode Island
McAllister Point Landfill Operation and Maintenance Naval Station Newport, Rhode Island Environmental Chemical Corporation Full service Environmental Remediation, UXO, and Operation & Maintenance (O&M)
More informationState of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation
Matrix: CWA (Non Potable Water) Discipline Chemistry EPA 1664A (SGT-HEM) n-hexane Extractable Material - Silica Gel Treated (HEM-SGT) 8/21/2015 Aluminum 8/21/2015 Arsenic 8/21/2015 Barium 8/21/2015 Beryllium
More informationNELAC PT for Accreditation Fields of Proficiency Testing with PTRLs Solid and Chemical Materials Effective: July 24, 2017
Trace Metals mg/kg mg/kg SOLIDS 1000 Aluminum 2500 to 25000 Study Mean 0.1307 293.1966 250 SOLIDS 1005 Antimony 80 to 300 Study Mean 0.4385 8.1700 8.0 SOLIDS 1010 Arsenic 40 to 400 Study Mean ± 30% SOLIDS
More informationAppendix A. Considering Risks from Indirect Pathways
Considering Risks from Indirect Pathways Considering Risks from Indirect Pathways A.1 What are Indirect Risks? IWAIR assesses exposures by direct inhalation of a chemical. It is possible, however, that
More informationIndoor Air Quality Monthly Testing Services, Corcoran Gallery of Art, th Street NW, Washington, DC December 2017
Mr. Dan Janniello, LEED AP The George Washington University 2025 F Street NW, Suite 200 Washington, DC 20052 djanniel@email.gwu.edu ECS Project No. 47:2199-A Reference: Indoor Air Quality Monthly Testing
More informationUrban Air Toxics Concentrations In Denver. May 2002 through April 2003
Urban Air Toxics Concentrations In Denver May 2002 through April 2003 October 2006 Prepared by the Colorado Department of Public Health & Environment Air Pollution Control Division (Technical Services
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PACE ANALYTICAL SERVICES, LLC MOBILE LAB SERVICES 1 2525 Advance Rd. Madison, WI 53718 Pat Letterer Phone: 608 221 8700 ENVIRONMENTAL Valid To: March 31, 2020
More information2010 Air Toxics Summary
2010 Air Toxics Summary New Jersey Department of Environmental Protection INTRODUCTION Air pollutants can be divided into two categories: the criteria pollutants (ozone, sulfur dioxide, carbon monoxide,
More informationSubmittal Guidelines for Imported Soil. Soil Review & Acceptance Process
The following guidelines are provided as a prescriptive step process to ensure the contractual and regulatory requirements for Baylands Soil Processing are met and the appropriate quality control documentation
More informationGround Water Quality Standards Class IIA by Constituent
Standards Class IIA by Constituent Constituents Name CAS Num Acenaphthene 83 32 9 400 10 400 Acenaphthlyene 208 96 8 100 10 100 Acetone 67 64 1 6,000 10 6,000 Acetonitrile 75 05 8 100 9 100 Acetophenone
More informationDynamic Small-Scale Chamber Emissions Testing
Dynamic Small-Scale Chamber Emissions Testing Compliance Report per California Dept. of Public Health Standard Method Version 1.1 and FloorScore Selit Bloc Underlayment Prepared for: 550 Old Peachtree
More informationGas Sampling Bags. Cost-Effective Alternatives for Air Sampling. Restek Air
Restek Air Gas Sampling Bags Cost-Effective Alternatives for Air Sampling Ideal for whole air sampling at ppb-ppm levels. Select from Tedlar, ALTEF, and multi-layer foil bags in a wide range of sizes.
More informationUS EPA Method Atomx XYZ and Agilent 7890B GC/5977A MS
Application Note Environmental US EPA Method 524.3 Atomx XYZ and Agilent 7890B GC/5977A MS Author Amy Nutter Applications Chemist, Teledyne Tekmar Abstract US EPA Method 524.3 was used to determine the
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationNELAC PT for Accreditation Fields of Proficiency Testing with PTRLs Solid and Chemical Materials Effective January 3, 2012
Trace Metals mg/kg mg/kg SOLIDS 1000 Aluminum 1000 to 25000 Study Mean 0.1082 753.6118 100 SOLIDS 1005 Antimony 80 to 300 Study Mean 0.4385 8.1700 8.0 SOLIDS 1010 Arsenic 40 to 400 Study Mean 0.0915 1.0653
More informationUpdate and Analysis of Current Boiler Operations Used for the Generation of Steam Heat and Electricity
Energy and Environment Research; Vol. 7, No. 1; 2017 ISSN 1927-0569 E-ISSN 1927-0577 Published by Canadian Center of Science and Education Update and Analysis of Current Boiler Operations Used for the
More informationCollegeville Area Air Monitoring Project Second Report. March 7, Commonwealth of Pennsylvania Department of Environmental Protection
Second Report Commonwealth of Pennsylvania Department of Environmental Protection Edward G. Rendell, Governor Commonwealth of Pennsylvania Kathleen A. McGinty, Secretary Department of Environmental Protection
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SGS NORTH AMERICA INC. ALASKA DIVISION 200 W Potter Dr. Anchorage, AK 99518 Mary McDonald Phone: (907)-550-3203 mary.mcdonald@sgs.com ENVIRONMENTAL Valid To:
More informationClean Harbors (Sarnia) Air Monitoring Plan and Sampling Results
Clean Harbors (Sarnia) Air Monitoring Plan and Sampling Results Southwestern Region - Technical Support Section Updated October 21, 2011 Executive Summary The ministry is conducting air sampling in the
More informationATTACHMENT 3. Firestone Geomembrane Chemical Resistance Chart
ATTACHMENT 3 Firestone Geomembrane Chemical Resistance Chart Firestone Geomembrane exposure to these chemicals causes no swelling, softening or surface deterioration of the membrane. Acetamide Acryimide
More informationEffective: July 18, 2017 Supersedes: August 9, RE: Conflict Minerals. Dear Customer:
Effective: July 18, 2017 Supersedes: August 9, 2016 RE: Conflict Minerals Dear Customer: The Dow Chemical Company (Dow) is pleased that your company is a member of the community of companies committed
More informationADEQ OPERATING AIR PERMIT
ADEQ OPERATING AIR PERMIT Pursuant to the Regulations of the Arkansas Operating Air Permit Program, Regulation #26: IS ISSUED TO: Teris L.L.C. 309 American Circle El Dorado, AR 71730 Union County AFIN:
More informationVAL QTY QTY SYNTHETIC ACRYLIC FIBRE SYNTHETIC FIBRES
ACRYLIC FIBRE 10579 12600 24522 44634 26383 37398 19258 26183 31562 47385 37420 NYLON FILAMENT YARN 2102 4733 2110 4925 1923 5412 1865 5728 2023 7402 1848 NYLON INDUSTRIAL YARN/TYRE CORD 2208 2783 3976
More informationPottstown Area Air Monitoring Final Report. January 19, Commonwealth of Pennsylvania Department of Environmental Protection
Pottstown Area Air Monitoring Final Report Commonwealth of Pennsylvania Department of Environmental Protection Edward G. Rendell, Governor Commonwealth of Pennsylvania Kathleen A. McGinty, Secretary Department
More informationParticipating Schedule for 2018/19
Participating Schedule for /19 Water Chemical Analysis Sample Name Analytes Enrolment Date Sample Dispatch Period Quarter 1 of Sample 3A: Mineral Constituents in potable water ph, Electrical Conductivity,
More informationPerfection in Liquid Handling HIGHEST RELIABILITY IN DISPENSING
Perfection in Liquid Handling HIGHEST RELIABILITY IN DISPENSING 13 VITLAB Dispenser line: genius 2, simplex 2, and TA 2 VITLAB genius 2 and simplex 2 bottle-top dispensers are a family of instruments with
More informationCollegeville Area Air Monitoring Project Third Report. November 17, Commonwealth of Pennsylvania Department of Environmental Protection
Third Report Commonwealth of Pennsylvania Department of Environmental Protection Edward G. Rendell, Governor Commonwealth of Pennsylvania John Hanger, Secretary Department of Environmental Protection Prepared
More informationCHEMICALS ALCOHOLS BASES
ACIDS Acetic Acid Acetic Acid Glacial Acetic Acid, Acrylic Acid Aqua Regia Benzene Sulfonic Acid Benzoic Acid Boric Acid Carbolic Acid Carbonic Acid Chloroacetic Acid Chlorosulfonic Acid D D D Chromic
More informationIndustrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:
08-13-2003 Page #1 of 13 Temperature ( o F) for Acetaldehyde --- 100 100 Acetic Acid #10 150 150 Acetic Acid 10-100 CM CM Acetic Anhydride --- 100 120 Acetone --- 120 120 Acetonitrile --- 120 120 Acetophonone
More informationExact Scientific Services, Inc. Ferndale, WA
Ferndale, WA has complied with provisions set forth in Chapter 173-50 WAC and is hereby recognized by the Department of Ecology as an ACCREDITED LABORATORY for the analytical parameters listed on the accompanying
More informationRoger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1
Application Note US EPA Method 524.3 with the Tekmar Lumin P & T Concentrator and Agilent 7890B GC and 5977A MSD System Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1 Abstract US EPA Method
More informationRYTON (PPS) Chemical Compatibility & Chemical Resistance Chart
RYTON (PPS) Chemical Compatibility & Chemical Resistance Chart Explanation of Footnotes 1. Satisfactory to 72 F (22 C) 2. Satisfactory to 120 F (48 C) Ratings -- Chemical Effect A = Excellent. B = Good
More informationRoger Bardsley, Applications Chemist; Teledyne Tekmar Page 1
Application Note US EPA Method 524.4 with the Tekmar Lumin P & T Concentrator and Agilent 7890B GC and 5977A MSD System Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Abstract US EPA Method
More informationWE ARE A TRUE PARTNER FOR YOUR SUCCESS
WE ARE A TRUE PARTNER FOR YOUR SUCCESS DONIT Tesnit Sealing technologies As a leader in gaskets, gasket sheets, and advanced sealing technologies, DONIT Tesnit offers the optimum solution with a perfect
More informationValidation Guide. GBPES-series 0.2, 0.45, & 0.65 Micron Membrane Elements F517A_160901
Validation Guide GBPES-series 0.2, 0.45, & 0.65 Micron Membrane Elements F517A_160901 Table of Contents I. Technical Specifications... 3 1. Mechanism of Filtration... 3 2. Pore Size... 3 3. Materials of
More informationCadmium B ug/l HRL Chromium B ug/l MCL 100
Appendix 4, Table A4-1 Inorganics/Metals Arsenic 7440-38-2 6010B ug/l 25 4.41 10 MCL 2 Barium 7440-39-3 6010B ug/l 10 1.04 2000 HRL Use Tier 2 5 (or hardnessspecific value if lower) Cadmium 7440-43-9 6010B
More informationUsing Alternative Carrier Gas for US EPA Application Note. Abstract. Introduction. Experimental-Instrument Conditions
Using Alternative Carrier Gas for US EPA 524.3 Application Note Abstract Due to regional shortages and increasing costs of helium, the preferred carrier gas in gas chromatography, alternative carrier gas
More informationPasco County Florida. Water Monitoring Plan West Pasco Class I Landfill PA87-23, WACS # Revised April 2014
Pasco County Florida Water Monitoring Plan West Pasco Class I Landfill PA87-23, WACS # 45799 Revised April 2014 Table of Contents Section 1 Introduction... 1 Section 2 Groundwater Quality Monitoring Network...
More informationVolatile Organic Compounds in Soil PBM
Organics Revision Date: Sept 15, 2017 Volatile Organic Compounds in Soil PBM Parameter Analytical Method Introduction Method Summary MDL(s) and EMS Analyte Codes Volatile Organic Compounds (VOCs) in solids.
More informationTPU CHEMICAL RESISTANCE CHART
TPU CHEMICAL RESISTANCE CHART Ratings Guide Good Should have little or no effect on the material at the given concentration and temperature Moderate Some effect on the material at the given concentration
More informationBioproducts as Early-Stage Technology Opportunities for Industry and Investors. Peter L Keeling Iowa State University
Bioproducts as Early-Stage Technology Opportunities for Industry and Investors Peter L Keeling Iowa State University NSF Engineering Research Center CBiRC Biomass Feedstock Biobased Chemicals Members -
More informationSTATE OF ILLINOIS ENVIRONMENTAL PROTECTION AGENCY NELAP - RECOGNIZED ENVIRONMENTAL LABORATORY ACCREDITATION. is hereby granted to
STATE OF ILLINOIS ENVIRONMENTAL PROTECTION AGENCY NELAP - RECOGNIZED ENVIRONMENTAL LABORATORY ACCREDITATION is hereby granted to ARDL, INC. 400 AVIATION DRIVE, P.O. BOX 1566 MT. VERNON, IL 62864 NELAP
More informationPolicy on Monitoring of Stack Emissions to Air at EPA Licensed Sites
Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites 1. OVERVIEW In Ireland at present industrial air emissions monitoring at licensed/permitted sites is required to be carried out by ISO17025
More informationGuide to Safe Handling & Storage of Hazardous Materials
Guide to Safe Handling & Storage of Hazardous Materials I. ACIDS VI. PYROPHORICS II. BASES (CAUSTICS) VII. PEROXIDE FORMING CHEMICALS III. FLAMMABLES VIII. TOXIC CHEMICALS IV. OXIDIZERS IX. CARCINOGENS
More informationTABLE A.15 ESTIMATED MAXIMUM DESORBER FURNACE NATURAL GAS COMBUSTION PRODUCTS EMISSIONS CLEAN HARBORS CANADA INC. CORUNNA, ONTARIO
Page 1 of 1 TABLE A.15 ESTIMATED MAXIMUM DESORBER FURNACE NATURAL GAS COMBUSTION PRODUCTS EMISSIONS Heat Rating (BTU/Hr) = 72,000,000 (Total BTU for both burners) Scenario #1 - fired using distillate fuel
More informationDraeger-Tubes and accuro Pump
Draeger-Tubes and accuro Pump Trusted Technology that s ahead of its time Accurate Easy to read Flexible Fast Specific Easy to use Maintenance free Multi-Gas Detector accuro pump One handed operation What
More informationApplications / Compatibility Guide
Applications / Compatibility Guide Hunsworth Lane, Cleckheaton, West Yorkshire. BD19 3UJ Telephone: +44 1274 878787 Fax: +44 1274 862588 e.mail: smith@novussealing.com Website: www.novussealing.com If
More informationDynamic Small-Scale Chamber Emissions Test
Dynamic Small-Scale Chamber Emissions Test Classroom Desk Compliance Report Per LEED for Schools & CHPS Low-Emitting Furniture Criteria flipit Desk (Exemplar for certification and product bracketing) Prepared
More information