1 Uniclass EPIC CI/SfB April 24 Roof s

2 Aprivately owned U.K. company with more than forty years experience in the industry, Wade is established as a leading manufacturer of quality drainage products. Much of the success of the business is attributable to an on-going commitment to put technology to practical use, to generate fresh ideas, and to guarantee quality assured production. This Technical Handbook presents illustrations and data from a comprehensive range of products which provide choices to enable the specifier/user to select roof outlets that will meet his/her requirements. Certification of compliance with BS EN ISO 91 underlines our commitment to quality and service.

3 Contents A-Z Accessories Balcony s Car Park s Considerations when Selecting Roof s Cold Roof s Typical Installations Series (Medium Sump) Series (Deep Sump) Downspout Nozzles Floor Gullies Flow Rates Glossary Green Roof Drainage Heated Roof s , 21 Index of Spec. Codes Installation Guidelines Insulated Roof s , 21 Inverted Roof s Typical Installations Series (Medium Sump) Series (Medium Sump) Series (Deep Sump) Linear Drainage Materials Maintenance No Fines Screed Roof 'Inverted Roof' Overflow s contact Technical Services Dept. Parapet s Planting Area Drainage Roof Garden Drainage Single Ply Membrane Roof s Spigot Adaptors Warm Roof s Typical Installations Series (Medium Sump) Series (Deep Sump)

4 CONSIDERATIONS WHEN SELECTING ROOF OUTLETS The purpose of roof outlets is to provide effective drainage of rainwater. Selection of roof outlets is usually the responsibility of the specifying engineer conversant with the roof construction, roofing finish, drainage system and designated function such as a garden or parking. Some of the factors that should be considered when selecting roof outlets are: BUILDING REGULATIONS / STANDARDS National and local regulations must be complied with in matters concerning drainage of rainwater. ROOF CONSTRUCTION Roof outlets are not multi-purpose, versions are designed for use with specific types of roof construction. The depth of the structural slab, thickness and location of insulation, and the type and location of waterproofing membrane are factors to be considered. FLOW RATE The quantity and types of roof outlet to be used in a given application must be related to the roof area and expected volume of rainwater to be drained. Flow rate is the amount of water (litres/sec) a roof outlet will drain at a given head; it is influenced by several factors: grating free area, sump capacity, design of the roof outlet, outlet size, and accessories such as gravel guards and filter buckets. Flow rates of Wade roof outlets have been established by full scale tests, at various heads of water. Results are shown on pages 2 to 29. THERMAL INSULATION To prevent condensation in roofs of heated buildings where the relative humidity may be expected to rise above 4%, it may be necessary to install additional insulation around roof outlet bodies. In applications subject to heavy snow or icing up, it may be desirable to include trace heating. APPEARANCE Whilst of pleasing appearance, gratings are designed to be relatively inconspicuous when installed. For areas where a better class of finish is required, some products are available made of nickel bronze. ACCESSORIES AND VARIATIONS Standard optional items are readily available, such as filter buckets to intercept debris, gravel guards, bearing pans to spread the load over a large area, and underdeck clamps to secure bodies. Custom made products can be manufactured for nonstandard applications. MATERIALS AND FINISHES Strength, corrosion resistance and appearance are important considerations when selecting roof outlets. LOAD RATING It is essential that roof outlets withstand expected loads. This Technical Handbook shows the load rating class for each grating or roof outlet assembly, based on BS EN 1253, as follows: K3 - Areas without vehicular traffic, such as balconies, terraces and roof gardens. L15 - Areas with light vehicular traffic. M125 - Areas with vehicular traffic, such as car parks, factories and workshops - not including light commercial vehicles or heavy wheel loads. PIPEWORK The type and size of pipework in a given installation is fundamental to the selection of roof outlets. Wade roof outlets can be connected to all pipework in general use; certain bodies are for direct connection to pipework, others require the use of spigot adaptors or proprietary couplings. 4

5 MATERIALS Materials and finish of Wade roof outlets, described below, are selected to provide lasting performance and to blend with surroundings. CAST IRON - BS EN 1561 Used for bodies, membrane clamping collars,extensions and spigot adaptors. A widely used metal in the drainage industry, its resistance to corrosion permits extended use under extreme conditions. Castings are coated with a high grade lacquer paint, applied by full immersion dip, to provide internal and external surface coverage. Paint will gradually wear off and is replaceable; oxidisation (surface rusting) is a natural process which does not weaken the material. DUCTILE IRON - BS EN Used only for gratings. A casting with the ductility of steel, yet with more than twice the tensile strength of. A zinc anti-corrosion coating is applied by sherardizing. STAINLESS STEEL - AUSTENITIC GRADE 34 Used for gratings, gravel guards, filter buckets and all fastenings. A corrosion-resistant metal containing significant amounts of nickel and chromium. GALVANISED MILD STEEL Used for adjustable bearing pans and raising tubes. A cost effective, corrosion resistant material. CAST ALUMINIUM - LM6 Used for parapet gratings. An alloy chosen for its chemical resistance and durability. GUNMETAL - BS 14 Used for downspout nozzles. A cast alloy suited for finished areas where the rich, bronze colour complements the decor. NICKEL BRONZE - BS 14 Satin finish Used for gratings A cast alloy which will maintain its lustre when subjected to the abrasive polishing action of traffic. The satin finish produces a fine grain effect which blends well with walls and floors. POLYCARBONATE Used for domes A polycarbonate/abs blend which offers durability, high impact strength and long term resistance to ultraviolet light. PVC Used for body versions for use with PVC single ply membranes. This material enables a waterproof joint to be produced on site. ABS Used for spigot adaptors CARE AND MAINTENANCE The products require the minimum of maintenance, but periodic inspection should be carried out to ensure that roof outlets are free from gravel, leaves and other debris which could impair the performance of the system. Cast iron parts should be repainted every five years. 5

6 Various Wade roof outlets are installed in the terminal buildings at Manchester Airport WB2 Series roof outlet for use in a cold roof. Wade designs and manufactures roof outlets for use with specific types of roof construction, worldwide. This Technical Handbook includes ranges of standard products which are generally available ex stock. Custom made products and accessories can be designed to suit particular applications. Please contact our Technical Services Dept for details. 6

7 WB Series are installed in the Inma Building, Beirut. WF1 Series parapet outlets are available with choice of grating -, aluminium and nickel bronze; a version is available for use with PVC single ply membranes. Balcony outlets are available with full grating or with cut-out version to accept a downpipe Variation of a WD Series roof outlet in an inverted roof.

8 Flat gratings of ductile iron, with sherardized protective coating, are available in different styles and sizes. For use in show areas, certain gratings can be manufactured of nickel bronze. 8

9 ROOF OUTLETS FOR WARM ROOF A warm roof is constructed such that the waterproofing membrane is above insulation which is laid on the roof deck. WC44 Wade offers a range of roof outlets for use in warm roofs. Versions are shown on pages 9 to 13, summarised as follows 34 Series (Medium Sump) Load-bearing applications For use with insulation thicknesses between 8 and 1mm - with dome - with circular flat grating Non load-bearing applications For use with insulation thicknesses between 2 and 135mm - with dome - with circular flat grating 31 Series (Deep Sump) Load-bearing applications For use with insulation thicknesses between 8 and 115mm - with dome - with square flat grating - with circular flat grating Non load-bearing applications For use with insulation thicknesses between 2 and 135mm - with dome - with square flat grating - with circular flat grating Features All bodies have a generous flange, essential for bonding asphalt or other membrane. All fixings are of stainless steel. LOAD RATING The load rating class is shown for each roof outlet; explanation of classes is given on page 4. FLOW RATE Area drained (m 2 ) is given for each roof outlet at a head of 35mm and rainfall rate of 5mm/h or.21 l/s per m 2. Graphs comparing the flow rate performance of roof outlets at different heads are shown on pages 28 and 29. ACCESSORIES A range of accessories is shown on page 21. CONNECTIONS Bodies with spigot outlet are for direct connection to BS 416 pipework; versions with threaded outlet are for connection to pipework by means of a spigot adaptor, a range of which is shown on page 21. Typical Installations 34 Series (Medium Sump) roof outlet with optional accessories. Load-bearing applications Non Load-bearing applications CLAMPING COLLAR EXTENSION FLANGE BEARING PAN (OPTIONAL) CLAMPING COLLAR ADJUSTABLE BEARING PAN INSULATION INSULATION ROOF DECK ROOF DECK BONDED INSULATION JACKET WITH OR WITHOUT TRACE HEATING (OPTIONAL) UNDERDECK CLAMP (OPTIONAL) NOTE: Details of bonded insulation jackets are given on page 21. BONDED INSULATION JACKET WITH OR WITHOUT TRACE HEATING (OPTIONAL) RAISING TUBE BODY On site the raising tube can be easily slide-positioned through the bearing pan to suit any insulation thickness from 2mm to 135mm. When the required height is achieved, the tube is secured to the bearing pan using the self-tapping screws provided. The bearing pan is designed to be fixed to the deck/slab, so an underdeck clamp is not necessary. 9

10 ROOF OUTLETS FOR WARM ROOF 34 Series Membrane clamping collar, (Medium Sump) For use with insulation thicknesses between 8 and 1mm. (*Previously 45-6mm) Secured dome, polycarbonate 11 Connecting spigot, Extension flange, Extension clamp, with neoprene gasket Load rating class: K3 * Spec Area Drained Weight WC222 2" BSP WC223 3" BSP WC224 4" BSP Spigot 11 *8-1 5 Horizontal 11 *8-1 spigot conforms to BS 416 'B'dia. 195 Spec A B Area Drained Weight Code Size Dia. m 2 kg WC WC WC 'B' Spec A B C Area Drained Weight WC232 2" BSP WC233 3" BSP WC234 4" BSP 'C' Membrane clamping collar, Secured grating, sherardized ductile iron *8-1 Connecting spigot, Extension flange, Extension clamp,, with neoprene gasket Load rating class: L15 Spec Area Drained Weight WC322 2" BSP WC323 3" BSP WC324 4" BSP Spigot *8-1 5 Horizontal *8-1 1 'C' spigot conforms to BS 416 'B'dia. 195 Spec A B Area Drained Weight Code Size Dia. m 2 kg WC WC WC 'B' Spec A B C Area Drained Weight WC332 2" BSP WC333 3" BSP WC334 4" BSP

11 ROOF OUTLETS FOR WARM ROOF 34 Series (Medium Sump) For use with insulation thicknesses between 2 and 135mm Membrane clamping collar, Secured dome, polycarbonate Raising tube, galvanised mild steel Adjustable bearing pan, galvanised mild steel Load rating class: for non-load bearing areas 11 Spigot min. 135 max min. 135 max. 24 dia. 5 x 5 Spec Area Drained Weight WC422 2" BSP WC423 3" BSP WC424 4" BSP 'B' dia. 24 dia. 5 x 5 Spec A B Area Drained Weight Code Size Dia. m 2 kg WC WC WC Membrane clamping collar, Secured grating, sherardized ductile iron Raising tube, galvanised mild steel Adjustable bearing pan, galvanised mild steel Load rating class: for non-load bearing areas Spigot min. 135 max min. 135 max. 24 dia. 5 x 5 'B' dia. 24 dia. 5 x 5 Spec Area Drained Weight WC522 2" BSP WC523 3" BSP WC524 4" BSP Spec A B Area Drained Weight Code Size Dia. m 2 kg WC WC WC

12 ROOF OUTLETS FOR WARM ROOF 31 Series (Deep Sump) - - For use with insulation thicknesses between 8-115mm. 45 dia. 31 dia. Slotted membrane clamping collar, sherardized Extension clamp,, with neoprene gasket Secured dome, polycarbonate Extension flange, A 6 Load rating class: K3 186 dia dia. Spec A Area Drained Weight WC644 4" BSP WC646 6" BSP Membrane clamping collar, Secured grating, sherardized ductile iron 45 dia. 32 sq Extension clamp,, with neoprene gasket Extension flange,. Load rating class: M A 186 dia dia. Spec A Area Drained Weight WC44 4" BSP WC46 6" BSP Slotted membrane clamping collar, sherardized. Secured grating, sherardized ductile iron 45 dia. 31 dia. Extension clamp,, with neoprene gasket Extension flange, Load rating class: L A dia dia. Spec A Area Drained Weight WC144 4" BSP WC146 6" BSP

13 ROOF OUTLETS FOR WARM ROOF 31 Series (Deep Sump) - - For use with insulation thicknesses between 2 and 135mm Slotted membrane clamping collar, sherardized. Secured dome, polycarbonate dia. 31 dia. Adjustable bearing pan, galvanised mild steel 135 A 2 min. 135 max. 356 dia. 6 x 6 Raising tube, galvanised mild steel Load rating class: for non-load bearing areas Spec A Area Drained Weight WC814 4" BSP WC816 6" BSP Membrane clamping collar, Secured grating, sherardized ductile iron 45 dia. 32 x A 2 min. 135 max. Adjustable bearing pan 356 dia. 6 x 6 Raising tube, galvanised mild steel Load rating class: for non-load bearing areas Spec A Area Drained Weight WC914 4" BSP WC916 6" BSP Slotted membrane clamping collar, sherardized. Secured grating, sherardized ductile iron 45 dia. 31 dia. Adjustable bearing pan, galvanised mild steel 135 A 2 min. 135 max. 356 dia. 6 x 6 Raising tube, galvanised mild steel Load rating class: for non-load bearing areas Spec A Area Drained Weight WC1114 4" BSP WC1116 6" BSP

14 ROOF OUTLETS FOR COLD ROOF A cold roof is constructed such that the waterproofing membrane is at finished level and insulation (if any) is placed below the roof deck. WB414 & WB224 Wade offers a range of roof outlets for use in cold roofs.versions are illustrated on pages 14 to 16, summarised as follows : 34 Series (Medium Sump) 31 Series (Deep Sump) -with dome -with circular flat grating -with dome -with square flat grating -with circular flat grating Features All bodies have a generous flange, essential for bonding asphalt or other membrane. All fixings are of stainless steel. LOAD RATING The load rating class is shown for each roof outlet; explanation of classes is given on page 4. FLOW RATE Area drained (m 2 ) is given for each roof outlet at a head of 35mm and rainfall rate of 5mm/h or.21 l/s per m 2. Graphs comparing the flow rate performance of roof outlets at different heads are shown on pages 28 to 29. Typical Installations 34 Series SECURED FLAT GRATING BODY SPIGOT ADAPTOR (SELECT SEPARATELY) 34 Series (Medium Sump) roof outlet with optional accessories. (Medium Sump) roof outlet. CLAMPING COLLAR ROOF DECK UNDERDECK CLAMP ( OPTIONAL ) SECURED DOME CLAMPING COLLAR ACCESSORIES A range of accessories is shown on page 21. CONNECTIONS Bodies with spigot outlet are for direct connection to BS 416 pipework; versions with threaded outlet are for connection to pipework by means of a spigot adaptor, a range of which is shown on page 21. BODY ROOF DECK 31 Series (Deep Sump) roof outlet with optional accessories. SECURED FLAT GRATING CLAMPING COLLAR ROOF DECK BODY SPIGOT ADAPTOR (SELECT SEPARATELY) UNDERDECK CLAMP (OPTIONAL) 14

15 ROOF OUTLETS FOR COLD ROOF 34 Series (Medium Sump) Membrane clamping collar, Secured dome, polycarbonate Load rating class: K3 195 Spec Area Drained Weight WB222 2 BSP WB223 3 BSP WB224 4 BSP Spigot 11 Horizontal 11 5 spigot conforms to BS 416 'B' dia. 195 Spec A B Area Drained Weight Code Size Dia. m 2 kg WB WB WB 'B' Spec A B C Area Drained Weight WB232 2" BSP WB233 3" BSP WB234 4" BSP 'C' Membrane clamping collar, Secured grating, sherardized ductile iron 9 5 Load rating class: L Spec Area Drained Weight WB322 2" BSP WB323 3" BSP WB324 4" BSP Spigot 5 Horizontal 1 'C' spigot conforms to BS 416 'B'dia. 195 Spec A B Area Drained Weight Code Size Dia. m 2 kg WB WB WB 'B' Spec A B C Area Drained Weight WB332 2" BSP WB333 3" BSP WB334 4" BSP

16 ROOF OUTLETS FOR COLD ROOF 31 Series (Deep Sump) - 45 dia. 31 dia. 11 Slotted membrane clamping collar, sherardized Secured dome. polycarbonate 6 46 Load rating class: K3 186 dia dia. Spec A Area Drained Weight WB414 4" BSP WB416 6" BSP dia. 32 x 32 Membrane clamping collar, Secured grating, sherardized ductile iron Load rating class: M dia dia. Spec A Area Drained Weight WB514 4" BSP WB516 6" BSP Slotted membrane clamping collar, sherardized Secured grating, sherardized ductile iron 6 45 dia. 31 dia. 46 Load rating class: L dia dia. Spec A Area Drained Weight WB614 4" BSP WB616 6" BSP

17 ROOF OUTLETS FOR INVERTED ROOF AND NO FINES SCREED An inverted roof is constructed such that the waterproofing membrane is above the roof deck and beneath the insulation. A no-fines screed roof is constructed such that a porous screed allows surface water to drain over the entire area; this method is frequently used for rooftop car parks. Typical Installations WD34 34 Series (Medium Sump) roof outlet with optional accessories. Wade offers a range of roof outlets for use in inverted and no-fines screed roofs.versions are illustrated on pages 1 to 2, summarised as follows: 34 Series (Medium Sump) -with dome CLAMPING COLLAR GRAVEL GUARD ROOF FINISH INSULATION 341 Series (Medium Sump) 31 Series (Deep Sump) -with circular flat grating -with square flat grating -with circular flat grating -with square flat grating BODY SCREED ROOF DECK UNDERDECK CLAMP (OPTIONAL) Features All bodies have a generous flange, essential for bonding asphalt or other membrane. All fixings are of stainless steel. LOAD RATING The load rating class is shown for each roof outlet; explanation of classes is given on page Series (Medium Sump) roof outlet with optional accessories. FLAT GRATING SLOTTED COLLAR / CLAMPING COLLAR ROOF FINISH FLOW RATE Area drained (m 2 ) is given for each roof outlet at a head of 35mm and rainfall rate of 5mm/h or.21 l/s per m 2. Graphs comparing the flow rate performance of roof outlets at different heads are shown on pages 28 and 29. ACCESSORIES A range of accessories is shown on page 21. BODY INSULATION ROOF DECK SPIGOT ADAPTOR (SELECT SEPARATELY) CONNECTIONS Bodies with spigot outlet are for direct connection to BS 416 pipework; versions with threaded outlet are for connection to pipework by means of a spigot adaptor, a range of which is shown on page 21. Notes: 34 Series The gravel guard is designed to retain insulation and prevent the ingress of gravel both in service and when the dome is removed for cleaning. 31 Series (Deep Sump) roof outlet with optional accessories Versions are available with extensions to suit varying thicknesses of insulation. FLAT GRATING SLOTTED COLLAR / CLAMPING COLLAR ROOF FINISH INSULATION ROOF DECK BODY SPIGOT ADAPTOR (SELECT SEPARATELY) 1

18 ROOF OUTLETS FOR INVERTED ROOF AND NO FINES SCREED 34 Series Gravel guard, perforated stainless steel (Medium Sump) Secured dome, polycarbonate Membrane clamping collar, Spigot Load rating class: K3 Horizontal 11 Spec Area Drained Weight WD122 2" BSP WD123 3" BSP WD124 4" BSP 'C' spigot conforms to BS 416 'B' dia 'B' Spec A B Area Drained Weight Code Size Dia. m 2 kg WD WD WD Spec A B C Area Drained Weight WD132 2" BSP WD133 3" BSP WD134 4" BSP Series (Medium Sump) Adjustable collar Secured 'Streamline' grating and frame stainless steel Slotted membrane clamping collar, Load rating class: K3 86 min. 113 max.* x Spigot 86 min. 113 max.* 5 2 x 2 Horizontal 86 min. 113 max.* Spec Area Drained Weight WD22 2" BSP WD23 3" BSP WD24 4" BSP x 2 'B' dia. 195 Spec A B Area Drained Weight Code Size Dia. m 2 kg WD WD WD * To increase height shown, use extensions WG51 / WG52 1 'C' 98 'B' Spec A B C Area Drained Weight WD32 2" BSP WD33 3" BSP WD34 4" BSP

19 ROOF OUTLETS FOR INVERTED ROOF AND NO FINES SCREED 341 Series (Medium Sump) Adjustable collar, Secured grating, sherardized ductile iron 8 min. 5 max. Slotted membrane clamping collar, Load rating class: L Spec Area Drained Weight WD222 2" BSP WD223 3" BSP WD224 4" BSP Spigot 8 min. 15 max.* 5 Horizontal 8 min. 15 max.* spigot conforms to BS 416 'B' dia 'B' 'C' Spec A B Area Drained Weight Code Size Dia. m 2 kg WD WD WD * To increase height shown, use extensions WG51 / WG52 Spec A B C Area Drained Weight WD232 2" BSP WD233 3" BSP WD234 4" BSP Adjustable collar, Secured grating, sherardized ductile iron 94 min. 121 max.* 224 x x 224 Slotted membrane clamping collar, Load rating class: L Spec Area Drained Weight WD322 2" BSP WD323 3" BSP WD324 4" BSP Spigot 94 min. 121 max.* 5 Horizontal 94 min. 121 max.* 224 x 224 spigot conforms to BS 416 'B' dia 'B' 'C' Spec A B Area Drained Weight Code Size Dia. m 2 kg WD WD WD * To increase height shown, use extensions WG51 / WG52 Spec A B C Area Drained Weight WD332 2" BSP WD333 3" BSP WD334 4" BSP

20 ROOF OUTLETS FOR INVERTED ROOF AND NO FINES SCREED 31 Series Deep Sump Adjustable collar Secured grating, sherardized ductile iron 9 min. 11 max.* Slotted membrane clamping collar, sherardized Slotted membrane clamping collar, 6 46 Load rating class: L dia dia. Spec A Area Drained Weight WD514 4" BSP WD516 6" BSP * To increase height shown, use extensions WG51 / WG x 224 Adjustable collar, Secured grating, sherardized ductile iron 16 min. 133 max.* Slotted membrane clamping collar, sherardized Slotted membrane clamping collar, 6 46 Load rating class: L dia dia. Spec A Area Drained Weight WD614 4" BSP WD616 6" BSP * To increase height shown, use extensions WG51 / WG52 2 x 2 Adjustable collar Secured 'Streamline' grating and frame stainless steel 98 min. 125 max.* Slotted membrane clamping collar, sherardized Slotted membrane clamping collar, 6 46 Load rating class: L dia dia. Spec A Area Drained Weight WD44 4" BSP WD46 6" BSP * To increase height shown, use extensions WG51 / WG52 2

21 ACCESSORIES - 31, 34, and 341 SERIES Gravel Guard - Stainless Steel For use with domes on all roofs having a deep gravel finish, to prevent ingress of insulation or gravel. Underdeck Clamp To secure a body to a roof deck. (Cannot be used with horizontal outlet) 6 25 'B' 34 Series 31 Series 34 Series 31 Series Spec Height Dia. Weight Code kg WG WG Spec Height Dia. Weight Code kg WH WH Spec Material A B Weight Code kg WG12 Mild Steel WG12SS S/Steel Spec Material A B Weight Code kg WH22 Mild Steel WH22SS S/Steel Bearing Pan - Galv. Mild Steel To spread the load over a larger area. (Cannot be used with horizontal outlet) Filter Bucket - S / Steel Used to intercept debris. Note: Filter buckets will reduce flow rate by varying extent depending on body selected. Extension - Stainless Steel Used to raise the height of a grating above a body. (Inverted roof only.) May be stacked to achieve extra height Series 31 Series Spec Size Weight Spec Size Weight Code kg Code kg WG21 5 sq. 2.3 WH31 61 sq Series,WD2,WD5 31 Series Spec Weight Code kg WG31.2 Spec Compatible Weight Code with kg WH41 WC6,WC1.6 WH42 WC-9,WC11,WB4-6.6 WD2-WD Series Spec Height Weight Code kg WG WG Bonded Insulation Jacket A factory fitted bonded insulation jacket is used to prevent condensation forming on the underside of a body. To specify/order add suffix K to the roof outlet Spec. Code. Trace heating of insulated bodies is available to help prevent blockage by ice or snow; for details please contact our Technical Services Dept. Spigot Adaptors A comprehensive range of spigot adaptors, shown in the following table, is available to enable bodies with BSP threaded outlet to be connected speedily and effectively to all pipework in general use. To complete the connection a coupling may be required as indicated. Longer spigots, such as required to pass through a slab, can be made in 1mm increments up to 1mm. To specify/order add suffix X and length (mm). On request, spigots may also be threaded both ends. For details, please contact our Technical Services Dept. PIPEWORK BODY SPIGOT ADAPTOR REQUIRED OUTLET COUPLING System Nom. Dia. BSP Spec. O.D. Length Material Weight mm Code mm mm kg Cast Iron BS " WT Mild Steel, sherardized 1. Proprietary Cast Iron BS " WT Mild Steel, sherardized 1. Proprietary Cast Iron BS " WT Cast Iron 2.5 Proprietary Cast Iron BS " WT Cast Iron 4. Proprietary Cast Iron BS43 1 4" WT Cast Iron 2.6 Proprietary Cast Iron BS " WT Cast Iron 4.1 Proprietary Cast Iron DIN (Ensign + SMU) 5 2" WT Mild Steel, sherardized 1. Proprietary Cast Iron DIN (SMU) 5 3" WT Mild Steel, sherardized 1.2 Proprietary Cast Iron DIN (Ensign) 5 3" WT Mild Steel, sherardized 1. Wade T163 Cast Iron DIN (Ensign + SMU) 1 4" WT Cast Iron 2.5 Proprietary Cast Iron DIN (Ensign + SMU) 15 6" WT Cast Iron 4. Proprietary Plastic 5 2" T Plastic (ABS).1 None Plastic 82 3" T Plastic (ABS).2 Proprietary Plastic 11 4" T Plastic (ABS).2 None Plastic 16 6" T Plastic (ABS).6 Proprietary Solvent weld socket 21

22 PARAPET OUTLETS Wade offers a range of parapet outlets with reversible body to provide horizontal or vertical threaded outlet. Parapet outlets can be used with downspout nozzles as illustrated on page 23. Versions WF12 to WF125 are supplied with a stainless steel membrane clamping collar. Flow Rate Area drained (m 2 ) is given for each parapet outlet in horizontal plane, at a head of 35mm and rainfall rate of 5mm/h or.21 l/s per m 2. Graphs comparing the flow rate performance of parapet outlets in horizontal and vertical planes at different heads are shown on page 2. GRATING BODY SCREED Accessory - Gravel Guard To specify/order add suffix G WF12 - WF125 Except where shown, assemblies have reversible bodies and stainless steel fixings 'B' WF152 - WF155 WF12 - WF125 WF 'B' 16 3 WF152 - WF155 WF166 WF162 - WF 'B' 16 WF162 - WF165 WF16 3 Spec A B Area Drained Weight Grating WF12 2" BSP Nickel Bronze WF13 3" BSP Nickel Bronze WF14 4" BSP Nickel Bronze WF15 4" BSP Nickel Bronze WF WF112 2" BSP Aluminium WF113 3" BSP Aluminium WF114 4" BSP Aluminium WF115 4" BSP Aluminium 91 6" BSP 64 WF122 2" BSP Cast Iron WF123 3" BSP Cast Iron WF124 4" BSP Cast Iron WF125 4" BSP Cast Iron WF152 2" BSP Aluminium WF153 3" BSP Aluminium WF154 4" BSP Aluminium WF155 4" BSP Aluminium WF156 6" BSP Aluminium WF " BSP WF162 2" BSP Aluminium WF163 3" BSP Aluminium WF164 4" BSP Aluminium WF165 4" BSP Aluminium WF166 6" BSP Aluminium WF WF16 6" BSP Aluminium 6" BSP With PVC body for use with single ply membrane; see page 25 for illustration

23 DOWNSPOUT NOZZLES - CAST GUNMETAL Wade offers a range of downspout outlets with threaded inlet, designed for installation on the outside face of a parapet wall to discharge water to lower levels. Typical Installation The illustration shows a downspout nozzle connected to a parapet outlet. Note: When specifying / ordering a connecting spigot, please advise the wall / parapet thickness. 18 dia dia. GRAVEL GUARD (OPTIONAL) Spec Weight Code Size kg WJ12 2" BSP 6.3 WJ13 3" BSP 4.4 WJ14 4" BSP DOWNSPOUT NOZZLE GRATING CLAMPING COLLAR 15 dia. 5 1 dia. CNNECTING SPIGOT BODY Spec Weight Code Size kg WJ22 2" BSP 2.1 WJ23 3" BSP BALCONY OUTLETS - CAST IRON For use on balconies with an asphalt finish, Wade offers balcony outlets with option of a full grating or with cut-out for a downpipe. 192 x 24 8 Flow Rate Area drained (m 2 ) is given for each balcony outlet at a head of 35mm and rainfall rate of 5mm/h or.21 l/s per m 2. Graphs comparing the flow rate performance of balcony outlets at different heads are shown on page Typical Installation The illustration shows a balcony outlet installed with an asphalt finish. The grating is designed to allow a rainwater down-pipe from the balcony above to be fitted into the body eliminating spillage onto the walkway. spigot conforms to BS416 / DIN19522 Spec Area Drained Weight WF64 1mm Load rating class: K3 111 RAINWATER DOWNNPIPE GRATING Cut out accepts downpipe of 116mm dia. max. 192 x BODY spigot conforms to BS416 / DIN19522 Spec Area Drained Weight WF4 1mm Load rating class: K3 23

24 DRAINAGE OF PLANTING AREAS AND ROOF GARDENS Wade offers a range of products providing drainage of moisture in planting areas and flower boxes, without loss of soil. For applications where a grating is required at the surface, in a paved area, or where access is required; for use with D1- D12 Series Bodies, shown on page 5B ntcibm of our Floor Gullies and Access Covers Technical Handbook and on our web site. 22 Dia. Grating Frame Ballast guard length is manufactured to specific requirements: 1mm min. Perforated Ballast Guard Spec Weight Code (min.) kg P81+ length (mm) 4. Clamp Collar Material: Grating - Ductile iron, sherardized Ballast Guard - Stainless steel Frame/Clamp Collar - Cast iron lacquered For applications where the standpipe is concealed by soil; for use with Vari-Level Bodies shown in section 5B of our Floor Gullies and Access Covers Technical Handbook and on our web site. Dome is removable for access purposes dia. Removable Dome SOIL DAMP PROOF Standpipe length is manufactured to specific requirements: 2mm min. Spec Weight Code (min.) kg P91+Standpipe Length (mm). VARI-LEVEL BODY 4" NPSM Thread Material: Dome - Copper Standpipe - PVC For applications where all drainage is concealed by soil; versions available to suit asphalt or sheet / brush on membranes. Type 1 SOIL DAMP PROOF Type 2 SOIL ASPHALT dia. Mesh Covered Dome SLAB Material: Dome - Cast iron, lacquered Mesh - Stainless steel C2-C5 SERIES BODY SLAB D1-D12 SERIES BODY Spec. Installation Membrane Dome Free Weight Code Type Area cm 2 kg P11 1 Sheet or brush on P12 2 Asphalt Body shown on pages 5Bntci1 /5Bntci2 of our Floor Gullies and Access Covers Technical Handbook and on our web site. Body shown on pages 5Bntcibm of our Floor Gullies and Access Covers Technical Handbook and on our web site. 24

25 ROOF OUTLETS FOR USE WITH PVC SINGLE PLY S Warm and Cold Roofs By application of a rigid PVC flange at our works, all versions of the 31 and 34 Series with the range of accessories, may be used with PVC single ply membranes. PVC based membranes may be solvent or heat welded directly to the PVC flange on site to produce a watertight seal. To specify/order add suffix Z to the Spec.Code. WC224Z roof outlet with WG12 underdeck clamp and WT13 spigot, in a warm roof with single ply membrane. Parapet s Wade offers a range of parapet outlets with reversible, PVC body, to provide horizontal or vertical threaded outlet, with grating options. Parapet outlets can be used with downspout nozzles as illustrated on page 23. Spec Grating Area Drained Weight WF15 4" BSP Nickel Bronze WF115 4" BSP Aluminium WF125 4" BSP Cast Iron WF155 4" BSP Aluminium WF165 4" BSP Aluminium For dimensions and drawings see page 22. WF15 parapet outlet with connecting spigot and WJ14 downspout nozzle. 25

26 FLOW RATES Flow rate testing a WB224 roof outlet Flow rates of Wade roof outlets have been established by full-scale tests. The values shown in graphs on pages 2-29 are 5% of such tests. The graphs show, for given heads of water, flow rate (l/s) and area drained (m 2 ) at a rainfall rate of 5mm/h** or.21 l/s per m 2.* *Rainfall Rate - BS EN l/s per m 2 equates to 5mm/h, as previously recommended in BS636 (superseded by BS EN :2). BS EN uses rainfall charts which provide more localised data given in l/s per m 2. To calculate the area drained [A] for a specific rainfall rate [R] (l/s per m 2 ) use the following formula..21 A(m 2 ) = x a (m l/s per m 2 ) R (l/s per m 2 ) (a: area drained, obtained from appropriate graph.) ** Rainfall Rate - BS 636 5mm/h has been used as previously recommended in BS 636 (withdrawn September 2). Area drained [A] at a different rainfall rate [R] can be calculated by using the following formula. 5 A(m 2 ) = x a (m 5mm/h) R (mm/h) (a: area drained, obtained from appropriate graph.) For assistance please contact our Technical Services Dept. 26

27 FLOW RATES 5 2" s: Horizontal Flow Rate (l/s) 1 A Parapet s 5 2" s: Vertical Flow Rate (l/s) 1 A Head (mm) 2 3 Head (mm) Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall 5 3" s: Horizontal Flow Rate (l/s) 1 A " s: Vertical Flow Rate (l/s) 1 2 A Head (mm) 2 2", 3" & 4" OUTLETS 3 Head (mm) Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall 5 4" s: Horizontal Flow Rate (l/s) 1 A " s: Vertical Flow Rate (l/s) A Head (mm) 2 1 A 3 Head (mm) Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall 6" s: Horizontal Flow Rate (l/s) 1 2B D C " OUTLETS Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall 6" s: Vertical Flow Rate (l/s) B C D 4 WF Head (mm) 2 B C WF166 3 Head (mm) Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall 5 WF16 D Balcony s 1mm s: Vertical Flow Rate (l/s) 1 2 B A Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall 4 3 Head (mm) 2 A WF6 Series Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall B WF Series 2

28 FLOW RATES 34 Series (Medium Sump) 2"/ 5mm 5 Flow Rate (l/s) A CD B 12 A WB2/22 WC2/22/4/42 4 WB3/32 WC3/32/5/52 WD2/22/3/32//2 Head (mm) 3 2 B WB23 WC23 1 C Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall D WB33 WC33 WD23/33/3 34 Series (Medium Sump) 3"/ 5mm 5 Flow Rate (l/s) B A D C 12 A WB2/22 WC2/22/4/42 4 WB3/32 WC3/32/5/52 WD2/22/3/32//2 Head (mm) 3 2 B WB23 WC23 1 C Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall D WB33 WC33 WD23/33/3 34 Series (Medium Sump) 4"/ 1mm 5 Flow Rate (l/s) D B C A 12 A WB2/22 WC2/22/4/42 Head (mm) B WB3/32 WC3/32/5/52 WD2/22/3/32//2 WB23 WC23 1 C Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall D WB33 WC33 WD23/33/3 28

29 FLOW RATES 5 31 Series (Deep Sump) 4"/ 1mm Flow Rate (l/s) D A B C 12 A WB6 WC1/11 4 WB4 WC6/8 Head (mm) 3 2 B WB5 WC/9 1 C Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall D WD5 WD6 WD4 31 Series (Deep Sump) 6"/ 15mm WB6 WC1/11 5 Flow Rate (l/s) D A 12 C B A 4 B WB4 WC6/8 Head (mm) 3 2 WB5 WC/9 1 C Roof Area Drained (m 2 ) at 5mm/h or.21 l/s per m 2 rainfall D WD5 WD6 WD4 29

30 INSTALLATION GUIDELINES General The design of the layout of roof outlets should be in accordance with the recommendations given in BS EN 1256:3. Wade roof outlets should be placed at the roof low points to allow efficient flow of water to the outlets. Illustrations of typical installations are given in each section of this handbook. 1. Check Dimensions Prior to installation, check height of components to ensure compatibility with roof build-up, making allowances for the membrane thickness. 2. Fit Spigot. Check Where applicable, screw spigot into body, using a suitable sealant to ensure the joint is watertight. Position body in roof deck and ensure that outlet is accessible for pipework connection. 3. Install Body Install body such that flange is flush or sub-flush with roof deck. Ensure body is fixed securely, either bonded or clamped to the deck if not cast-in. Note: Membrane flange level is determined by roof build up. 4. Dress Membrane and Clamp Refer to membrane manufacturer s instructions. Prepare flange of body with suitable primer and apply membrane, dressing over flange and into sump of body. Position membrane clamping collar and secure to body using fixings supplied. 5. Install Insulation Install any intermediate roof build-up (e.g. insulation) around outlets. 6. Fit Grating. Apply Finish Fit dome/grating using height adjustment where applicable to ensure grating is flush with roof finish. Apply roof finish around grating. 3

31 GLOSSARY AND INDEX Adjustable Bearing Pan Component used with a raising tube on ROOF OUTLETS for WARM ROOF which enables the installer to set the distance between the FLANGE and roof deck at any point between 2 and 135mm. Balcony Design of ROOF OUTLET with a flat GRATING; a version allows a downpipe from the level above, as well as surface water, to pass through. Bearing Pan Profiled plate into which a BODY can be located to spread the weight of the body over a larger area of roof. Body Bowl-like part of a ROOF OUTLET, set in the roof, to which the DOME or GRATING is fixed and the pipework connected. Bucket Removable receptacle fitted within a ROOF OUTLET to intercept debris. Clamp CLAMPING COLLAR OR UNDERDECK CLAMP Cold Roof Construction method where the waterproofing is at finished level and insulation (if any) is placed below the roof deck. Dome Removable, raised GRATING used on ROOF OUTLETS. The vertical slot design resists blockage by debris, leaves etc. Domical Grating DOME. Downspout Nozzle Decorative spout used to discharge rainwater through a wall to a lower level. Normally used with a PARAPET OUTLET. Extension Flange Raises the height of a GRATING above a BODY Flange Part of a BODY leading to its mouth, over which the waterproofing is laid. Flow Rate Maximum amount of water (I/sec) that can be drained at a given HEAD OF WATER. Frame Support for a GRATING which is connected to a BODY either directly or by means of a CLAMPING COLLAR. Gargoyle DOWNSPOUT NOZZLE Grating Removable, exposed component of a ROOF OUTLET with apertures to receive rainwater; generally fitted in a frame. Gravel Guard Mesh screen fitted to prevent gravel falling into the ROOF OUTLET when the DOME or GRATING is removed. Parapet outlet version must be removed first to gain access to grating. Green Roof Gardens, shrubberies etc. located on a roof Gully Discharge fitting designed to be installed in a floor.(please refer to Other Wade Literature on back page) Head of Water Height of water above the GRATING, used to determine FLOW RATE. l.d. Internal diameter Inverted Roof Construction method where the waterproofing is above the roof deck, and below the insulation. Load Rating Capability to withstand loads, expressed in classes. ( page 4 for details). Membrane Waterproofing material (asphalt, roofing felt, EPDM sheet, PVC etc.) laid on a roof to make it watertight. Membrane Clamping Collar Used to clamp a to a body. M.J. Mechanical joint No-Fines Screed Construction method normally used for roof-top car parks; the screed is porous and allows surface water to drain over the entire area. O.D. Outside diameter Part of a BODY through which rainwater is discharged into connecting pipework. Parapet A design of ROOF OUTLET allowing drainage horizontally through a parapet wall;can also be used vertically. Raising Piece EXTENSION FLANGE Raising Tube ADJUSTABLE BEARING PAN Roof An assembly generally comprising a BODY and DOME or flat GRATING, which allows the efficient drainage of rainwater from a roof. Single-ply Membrane PVC, waterproof, sheet material laid on a flat roof to make it watertight; requires ROOF OUTLETS with Z FLANGE. Spigot Adaptor Converts threaded outlet BODY to a spigot outlet allowing connection to pipework using a proprietary coupling. Spigot BODY with an integral spigot. Sump Part of a BODY between the FLANGE and OUTLET. BODY in which the OUTLET connection is a BSP thread into which a SPIGOT ADAPTOR can be fitted to allow connection to pipework. Two-Way PARAPET OUTLET Underdeck Clamp Framework fitted to the underside of a BODY under the roof deck, to hold the body firmly in place; normally used on metal deck roofing in conjunction with a BEARING PAN; may also be fitted on a concrete slab where casting-in is not possible. Warm Roof Construction method where the waterproofing is above insulation which is laid on the roof deck. Z Flange PVC collar which is factory fitted to the FLANGE of a BODY to enable jointing on site to a PVC SINGLE PLY. INDEX Spec Code Page Spec. Code Page P8 24 WF1 22,25 P9 24 WF6, 23 P1 24 T 21 WG 21 WB2,3 15 WH 21 WB WJ 23 WC2,3 1 WC4,5 11 WT 21 WC6, 12 WC8, WC WC WD1 18 WD2,3 18,19 WD5-6 2 WD-3 18 WD4 2 31

32 Information Technology from Wade Wade literature is available on CD ROM, accessible on an IBM compatible PC with a CD ROM drive and Windows 95 or above. The CD also includes WADE-CAD - a selection of drawings in both Autocad and DXF format, accessible on PC or Apple Mac. Our website also contains product information and CAD files. Uniclass EPIC CI/SfB (52) l l l l CI/SfB (52) April 1998 April 24 Drainage Products S E L E C T I O N A N D I N S T A L L A T I O N G U I D E Linear Drainage Service Product Information and technical advice are available from the Wade Technical Services Department at Halstead, Essex, from Wade Technical Consultants located throughout the U.K. and from selected distributors throughout the world. A computer-aided design service is available free of charge for layouts and assemblies of Wade products. Warranty The Company warrants its products to be free from defects in material and workmanship for a period of 12 months from the date of delivery. The Company s obligation under this warranty is limited, at its option, to the repair or replacement, free of charge, or refund of the net invoiced price of any part found to be defective, and which, in the Company s opinion, has not been subject to undue wear and tear, accident, alteration, abuse or misuse. Consequential damages are expressly disclaimed. Technical advice from Wade International Ltd., whether verbal, in writing or by way of trials, is given in good faith but without warranty. The application, use and installation of the Company s products are beyond the control of the Company, and the purchaser is solely responsible for ensuring that goods are fit for any particular purpose. In line with the Company s policy of continual research and development, product specifications and availability are subject to change or withdrawal without prior notice. Dimensions In line with general practice all dimensions shown are nominal. QUALITY BY TRADITION PERFORMANCE BY DESIGN WADE INTERNATIONAL LTD THIRD AVENUE. HALSTEAD ESSEX. CO9 2SX. U.K. TELEPHONE: +44 () FACSIMILE: +44 () tech@wadedrainage.co.uk. web site:

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

CI/SfB (52) Drainage Systems. frostdrainage.com

CI/SfB (52) Drainage Systems. frostdrainage.com CI/SfB (52) Drainage Systems frostdrainage.com Contents Introduction 3-7 What we do 3 Technical dvice and Support 4 dvantages of Frost Drainage Systems 5 Some UK Projects Some Worldwide Projects 7 Floor

More information

CI/SfB Oct 12 (52.5) Uniclass L7314

CI/SfB Oct 12 (52.5) Uniclass L7314 CI/SfB Oct 12 (52.5) Uniclass L7314 Bailey Flow-therm Product Selector A RANGE OF QUALITY AND ROBUST RAINWATER OUTLET AND VENTILATION SYSTEMS FOR FLAT ROOFS, MANUFACTURED FROM RIGID POLYURETHANE. Bailey

More information

FLOOR AND AREA DRAINS

FLOOR AND AREA DRAINS Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA

More information

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions. SECTION 07710 MANUFACTURED ROOF SPECIALTIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Roof drains for new roofing. B. Roof drains for reroofing. C. Roof drains for retrofitting into existing roof drains.

More information

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing). SECTION 15421 DRAINS AND CLEANOUTS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. Division 7 - Thermal and Moisture Protection. 2. 15410 - Piping (Plumbing). 1.02 SUBMITTALS A. Product Data: Submit

More information

CI/SfB (52) May Linear Drainage

CI/SfB (52) May Linear Drainage Uniclass EPIC CI/SfB (52) May 2007 Linear Drainage Aprivately owned U.K. company with more than forty years experience in the industry, Wade is established as a leading manufacturer of quality drainage

More information

LIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to for the most current product specification sheets.

LIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to  for the most current product specification sheets. www.mifab.com The Uncloggable Roof Drain Dome ROOFGUARD-2017 Go to www.mifab.com for the most current product specification sheets. DESIGNED, ASSEMBLED AND PACKAGED IN THE USA LIT-058 MIFAB, Inc. 1321

More information

The Uncloggable Roof Drain Dome LIT-058

The Uncloggable Roof Drain Dome LIT-058 www.mifab.com ROOFGUARD -018 CERTIFIED MANAGEMENT SYSTEM ISO 9001:015 Go to www.mifab.com for the most current product specification sheets. DESIGNED, ASSEMBLED AND PACKAGED IN THE USA The Uncloggable

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

ACO Building Drainage

ACO Building Drainage Uniclass L73144 CI/Sf6 S2 (52.5) November 2011 Drainage Systems ACO Building Drainage Product catalogue and specifiers design guide ACO Building Drainage Watertight Rainwater Outlets for Flat Roofs and

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15420 DRAINAGE AND VENT SYSTEMS PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. All cleanouts above finished (accessible and non-accessible) ceilings shall be extended to the floor above. B. Do

More information

ACO Building Drainage

ACO Building Drainage Uniclass L7315 Cl/SfB (52.5) April 2017 Drainage Systems Product catalogue ACO DeckLine 125 Galvanised Steel Channel System Our built environment is becoming ever more complex. Applications are becoming

More information

Roofgard Paving Support System

Roofgard Paving Support System Roofgard Paving Support System CI/SfB (47) January 2007 Adjustable paving support system for paved and raised deck applications One of a range of Roofgard accessories specially designed to meet the exacting

More information

Siphonic. Drain System. Engineered Water Solutions for Today s Building Design Needs

Siphonic. Drain System. Engineered Water Solutions for Today s Building Design Needs Siphonic Drain System Engineered Water Solutions for Today s Building Design Needs Table of Contents History of Siphonic Systems 2 Components of Siphonic Systems 2 Specifics of Siphonics 2 Conventional

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11294 - Stainless Steel Sluice Gates C O N T E N T S PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 DEFINITIONS... 1 1.04 DESIGN REQUIREMENTS...

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

1 ½

1 ½ HOW TO SELECT A FLOOR DRAIN Floor and area drains receive liquid from surrounding areas and by the attached piping, convey the liquid to the storm or sanitary drainage system. Floor drains are primarily

More information

SECTION FACILITY STORM DRAINAGE

SECTION FACILITY STORM DRAINAGE PART 1 - GENERAL 1.1 DESCRIPTION SECTION 22 14 00 Storm drainage systems, including piping and all necessary accessories as designated in this section. 1.2 RELATED WORK A. Penetrations in rated enclosures:

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass L7315 CI/SfB (52.5) EPIC J3413 ACO MultiDrain PPD ACO MultiDrain PPD system Medium duty channel drainage system ACO MultiDrain PPD Introduction to

More information

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only) Outline NBS Specification Protec System to PVC Single Ply (Waterproofing Only) This document is a guide to assist in the production of tender documents only and is not project specific. A site survey is

More information

Think Safety, Think Safesite O&M - KEEGUARD

Think Safety, Think Safesite O&M - KEEGUARD Think Safety, Think Safesite O&M - KEEGUARD Safesite Guardrail Systems SAFESITE GUARDRAIL SYSTEMS Safesite s guardrail systems including System 2000 and KeeGuard have been designed specifically to provide

More information

G-FIRE GROOVED COUPLINGS

G-FIRE GROOVED COUPLINGS G-FIRE GROOVED COUPLINGS Figure 5 G-FIRE Rigid Page 5 Figure 5 Flexible Page GRINNELL are designed for grooved end pipe and are available in nominal sizes of 25mm (") to 3mm (2") including BS, and ISO

More information

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION 07530CP EPDM MEMBRANE ROOFING PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL

More information

Drainage with system SELF structural elements

Drainage with system SELF structural elements Drainage with system SELF structural elements Drainage channels, boot scrapers, yard sumps for the house, yard and garden Contents 04 ANRIN SELF structural elements Material / Application / Properties

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING SECTION 221316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following soil and waste, sanitary drainage and vent piping inside the building: 1. Pipe, tube,

More information

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017 SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE Amended 28 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland 1746

More information

112mm. 117x75mm Polyflow. 130x70mm Ogee 68mm Round 65mm Square. 112mm Half Round 68mm Round. 65mm. Round. 112mm. 117x75mm Polyflow

112mm. 117x75mm Polyflow. 130x70mm Ogee 68mm Round 65mm Square. 112mm Half Round 68mm Round. 65mm. Round. 112mm. 117x75mm Polyflow Gutter and Systems A comprehensive range of fittings accompanies each rainwater profile in Polypipes unrivalled product range, to provide the specifier and installer with a complete roof drainage solution.

More information

Daytona Beach Pier Building Renovation Jun 2010

Daytona Beach Pier Building Renovation Jun 2010 SECTION 15150 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Guidance Document Podium Decks & Buried Roofs

Guidance Document Podium Decks & Buried Roofs Guidance Document Podium Decks & Buried Roofs March 2017 1 Guidance Document Podium Decks and Buried Roofs 1. INTRODUCTION 2. DEFINITIONS 3. DESIGN AND BUILD PHILOSOPHY 4. PODIUM DECKS 5. BURIED ROOFS

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to

More information

Flat Roof Drainage Systems PRODUCT OVERVIEW

Flat Roof Drainage Systems PRODUCT OVERVIEW Uniclass L7314 CI/SfB (52.5) X Flat Roof Drainage Systems PRODUCT OVERVIEW Contents 3 FIXFAST, quality for over 35 years 4 Water Management 6 Farbo 10 - FloDrain 12 - ParaDrain 13 - SumpDrain 14 - DuoDrain

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES SECTION 15440 - PLUMBING FIXTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, are a part of this Section. 1.02 SUMMARY A.

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Chapter contents. Balcony and terrace drainage. Point drainage. Line drainage. Balcony and terrace drainage

Chapter contents. Balcony and terrace drainage. Point drainage. Line drainage. Balcony and terrace drainage Chapter contents 8 Point drainage ACO balcony and terrace drains Stainless steel, material grade 304 Nominal width: DN 50 DN 100 As a single and direct drainage system For balconies and terraces With or

More information

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10 CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES 283 Chapter 10 FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS 10.1 PLASTERWORK Workmanship i. All workmanship must be within the tolerances

More information

CPM Concrete Drainage Systems

CPM Concrete Drainage Systems CPM Group Ltd offer a complete range of precast concrete manhole units from DN 900 to DN 4000 in varying depths with tongue and groove joints. A djusting units Ductile iron cover & frame Cover slab DN1200

More information

Siphonic Rainwater Drainage

Siphonic Rainwater Drainage HMSi SB1-PT JANUARY 2009 Siphonic Rainwater Drainage 1 Terrain HydroMax Siphonic Drainage Designed to rapidly remove the high volumes of water deposited in extreme rainfall events from the roof areas of

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of

More information

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

August 2008: Issue 1. Non - Residential New Build 4.5 Basements Non - Residential New Build 4.5 Basements August 2008: Issue 1 Non-residential new build 4.0 Non-residential New Build Basements Contents Introduction find online page Solution optimiser and pathfinder

More information

Channel Drains Barrier Free ADA Compliant NEW & IMPROVED DESIGN FOR EASIER INSTALLATION IAPMO LISTED. PRODUCT GUIDE: suggested list price book

Channel Drains Barrier Free ADA Compliant NEW & IMPROVED DESIGN FOR EASIER INSTALLATION IAPMO LISTED. PRODUCT GUIDE: suggested list price book Channel Drains 2012 PRODUCT GUIDE: suggested list price book EFFECTIVE MARCH 1, 2012 NEW & IMPROVED DESIGN FOR EASIER INSTALLATION ING END P T N E PAT Confidence from start to finish. 800.852.3906 orders@jaclo.com

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

MIGUTAN FP110 (Previously FP 90, name changed as part of metric standardization program)

MIGUTAN FP110 (Previously FP 90, name changed as part of metric standardization program) Manufacturer: MIGUTAN FP110 (Previously FP 90, name changed as part of metric standardization program) Watertight, Plaza Deck, & Split Slab Expansion Joint EMSEAL JOINT SYSTEMS, LTD 25 Bridle Lane Westborough,

More information

Specification. Project Name: Project reference: Written: by: Cathal Quinn Tel:

Specification. Project Name: Project reference: Written: by: Cathal Quinn   Tel: Project reference: 010050 Specification Written: by: Cathal Quinn Email: cathal@moymaterials.com Tel: 07788 934895 Project Name: Moy Materials Victoria House (4 th Floor) Victoria Road Chelmsford CM1 1JR

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment

More information

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints Installation Manual 1 1 Introduction This manual gives guidance on how to install the CPM Group Perfect manhole system

More information

SECTION TPO WATERPROOFING MEMBRANE FOR FLAT ROOFS INSTALATION

SECTION TPO WATERPROOFING MEMBRANE FOR FLAT ROOFS INSTALATION SECTION 07 54 23 TPO WATERPROOFING MEMBRANE FOR FLAT ROOFS INSTALATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Waterproofing of flat and sloped roofs. Application by loose laying with ballast, mechanical

More information

STORM DRAINAGE CHAPTER 11

STORM DRAINAGE CHAPTER 11 CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,

More information

MANUFACTURING STANDARD Clearway is manufactured using a semi dry method tested in accordance with European Standard BS EN 1433.

MANUFACTURING STANDARD Clearway is manufactured using a semi dry method tested in accordance with European Standard BS EN 1433. A CONCEALED LINEAR DRAINAGE SYSTEM WITH A DISCRETE CROSS-FALL WHICH DIRECTS SURFACE WATER TO WATER INLET. SPECIFICALLY DESIGNED FOR HARD LANDSCAPED AREAS, OFFERS A COST EFFECTIVE SOLUTION FOR ALL APPLICATIONS.

More information

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1 Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description Roofing Product Data Sheet Edition 11.2014 / xtra UK Identification no. 02 09 45 05 100 0 000019 Version no. 03 S-Vap 5000E SA Self-adhesive Vapour Barrier Product Description S-Vap 5000E SA is a multi-layer

More information

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems. PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and equipment support systems. B. Inserts. 1.02 RELATED SECTIONS A. Section 15890 - Ductwork Supports. 1.03 DEFINITIONS A. Supports: Attachments, hangers,

More information

Diffused Aeration Piping Equipment

Diffused Aeration Piping Equipment 1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections

More information

CONTENTS INTRODUCTION 2 FREEFLOW RAINWATER SYSTEMS Square Line Rainwater System 3-5. Half-Round Rainwater System 6-8. Ogee Rainwater System 9-11

CONTENTS INTRODUCTION 2 FREEFLOW RAINWATER SYSTEMS Square Line Rainwater System 3-5. Half-Round Rainwater System 6-8. Ogee Rainwater System 9-11 RAINWATER SYSTEMS CONTENTS INTRODUCTION 2 FREEFLOW RAINWATER SYSTEMS 3-3 Square Line Rainwater System 3-5 Half-Round Rainwater System -8 Ogee Rainwater System 9- Deep Rainwater System 2-3 INSTALLATION

More information

Sheet Metal Flashing and Trim

Sheet Metal Flashing and Trim University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 076200 - Sheet

More information

SECTION G RELIEF VENTS A-0

SECTION G RELIEF VENTS A-0 SECTION G A-0 TABLE OF CONTENTS Thaler Or Equal RV-1A/-RV-1C Relief Vent RV-2A/-RV-2C Relief Vent RV-3A/-RV-3C One Way Relief Vent Relief Vent Specification G-0 G-1 G-2 G-3 G-4, G-5, G-6 WHAT IT TAKES

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated

More information

Manufacturing standard. Clearway is manufactured using a semi dry method tested in accordance with European Standard BS EN 1433.

Manufacturing standard. Clearway is manufactured using a semi dry method tested in accordance with European Standard BS EN 1433. CI/SfB I I (52.5) I f I I Landscaping Charcon Clearway OHS61759 FM96927 EMS96928 A concealed linear drainage system with a discrete cross-fall which directs surface water to a drainage entrance. Specifically

More information

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated. SECTION 221316 SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

200 Series In-Slab Pool Fittings

200 Series In-Slab Pool Fittings 230 Series nti-vortex Plate 2-2 231 Series Sump 2-3 234 Series Sump 2-4 236 Series Sump 2-5 253 Series Overflow 2-6 255 Series Overflow/Drain 2-7 261 Series Vacuum Fitting 2-8 263 Series Eyeball Fitting

More information

CONTENTS INTRODUCTION 2 FREEFLOW RAINWATER SYSTEMS Square Line Rainwater System 3-5. Half-Round Rainwater System 6-8. Ogee Rainwater System 9-11

CONTENTS INTRODUCTION 2 FREEFLOW RAINWATER SYSTEMS Square Line Rainwater System 3-5. Half-Round Rainwater System 6-8. Ogee Rainwater System 9-11 RAINWATER SYSTEMS CONTENTS INTRODUCTION 2 FREEFLOW RAINWATER SYSTEMS 3-3 Square Line Rainwater System 3-5 Half-Round Rainwater System -8 Ogee Rainwater System 9- Deep Rainwater System 2-3 INSTALLATION

More information

TAPPING SADDLES DN 40 - DN 450

TAPPING SADDLES DN 40 - DN 450 TAPPING SADDLES 0-0 FAST, PERMANENT TAPPING SOLUTION FOR BOTH RIGID AND FLEXIBLE PIPE TYPES FEATURES bodies are manufactured from either stainless steel or Ductile Iron Fusion Bonded Epoxy coated (depending

More information

June Residential Refurbishment Basements

June Residential Refurbishment Basements June 2010 Residential Refurbishment 3.5.1 Basements Residential refurbishment 3.0 Residential Refurbishment Basements Contents Introduction find online page Solution optimiser and pathfinder 293 Design

More information

Specification Drainage Engineering Guide. Hydrants.

Specification Drainage Engineering Guide. Hydrants. Specification Drainage Engineering Guide Hydrants www.zurn.com APPLICATION INDEX WALL HYDRANTS NON-FREEZE/SELF-DRAINING MODERATE CLIMATE Retail Outlets Z1300, Z1305, Z1310, Z1320 Z1330, Z1335 Office Buildings

More information

ACO Marine. ACO Scuppers - ACO Channels ACO Drainage Systems for Shipbuilding and Offshore Installations

ACO Marine. ACO Scuppers - ACO Channels ACO Drainage Systems for Shipbuilding and Offshore Installations ACO Marine ACO Scuppers - ACO Channels ACO Drainage Systems for Shipbuilding and Offshore Installations Basic characteristic Through a consistent and effective product development, ACO Marine has developed

More information

Safety Barrier Solutions

Safety Barrier Solutions S E P A R A T I N G P E O P L E F R O M H A Z A R D S Safety Barrier Solutions SOLUTIONS TO YOUR BARRIER NEEDS SIMPLE TO DESIGN AND SPECIFY UNRIVALLED TECHNICAL SUPPORT WORLDWIDE AVAILABILITY The Kee Safety

More information

Pocket Guide to Cold Applied Liquid Waterproofing. Flat Roofs Green Roofs Balconies Walkways Podia Terraces. abc

Pocket Guide to Cold Applied Liquid Waterproofing. Flat Roofs Green Roofs Balconies Walkways Podia Terraces. abc Pocket Guide to Cold Applied Liquid Waterproofing Flat Roofs Green Roofs Balconies Walkways Podia Terraces abc Contents Cold Applied Waterproofing Systems Page No. Introduction 4 Rapid Cure Roofing System

More information

Pre-Sloped Drain System

Pre-Sloped Drain System SportsEdge PolyDrain Pre-Sloped Drain System www.sportsedge.com Quality. Safety. Versatility. Aesthetics. 2 PolyDrain FORMULA www.sportsedge.com ABT, Inc. manufactures PolyDrain trench drains; the standard

More information

WANG TAPPING SADDLES. fast, permanent tapping SOLUTION FOR BOTH rigid and flexible pipe types FEATURES DESCRIPTION APPLICATION TECHNICAL DATA

WANG TAPPING SADDLES. fast, permanent tapping SOLUTION FOR BOTH rigid and flexible pipe types FEATURES DESCRIPTION APPLICATION TECHNICAL DATA WANG TAPPING SADDLES 0-0 fast, permanent tapping SOLUTION FOR BOTH rigid and flexible pipe types FEATURES bodies are manufactured from either stainless steel or Ductile Iron Fusion Bonded Epoxy coated

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying metal wall panels

More information

GE Commercial Floor Drains, Wastes & Cleanouts

GE Commercial Floor Drains, Wastes & Cleanouts GE Commercial Floor Drains, Wastes & Cleanouts www.galvinengineering.com.au ISO9001 Lic0133 SAI Global Introduction INDEX INTRODUCTION General Information... 2 Ordering & Specification Details... 3-4 Our

More information

Wet Room Floor Solutions

Wet Room Floor Solutions Wet Room Floor Solutions The Benefits of UniSlope Wet Room systems Luxurious Lifestyle Open plan bathroom that creates a more attractive space. Complements contemporary design. UniSlope Highline Custom

More information

Gas Protection System Components

Gas Protection System Components Page 1 Visqueen Gas Protection Visqueen Building Products is recognised as the leader in the development, production and supply of high quality construction related ground gas protection membranes. The

More information

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY Section Includes: 1. Pipe and fittings. 2. Drain Basin. 3. De-chlorination tablet feeder. 4. Non-pressure transition couplings.

More information

(For compliance with the new sewers for adoption regulation or building regulations part H1)

(For compliance with the new sewers for adoption regulation or building regulations part H1) Plastic Drainage Keyline offers a comprehensive range of products suitable for all building, foul, surface water and land drainage applications - including new innovative, cost-effective systems for compliance

More information

Pioneer Forced Draft Cooling Tower Specifications

Pioneer Forced Draft Cooling Tower Specifications Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower

More information

Applications. 5 reasons why you should choose Hebden X Grid cellular paving

Applications. 5 reasons why you should choose Hebden X Grid cellular paving 5 reasons why you should choose Hebden X Grid cellular paving The British-made Hebden X Grid cellular paving system can be filled with grass or gravel, then driven over, parked on and walked on whilst

More information

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer) NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS

More information

R10 RAINWATER DRAINAGE SYSTEMS

R10 RAINWATER DRAINAGE SYSTEMS R10 RAINWATER DRAINAGE SYSTEMS To be read with Preliminaries/General conditions. GENERAL INFORMATION/REQUIREMENTS 110 GRAVITY RAINWATER DRAINAGE SYSTEM - Rainwater outlets: Proprietary (see clause 365)

More information

H series. for upper balconies DN 100. DN 100 Vers. a X X. Partial unit Side drain

H series. for upper balconies DN 100. DN 100 Vers. a X X. Partial unit Side drain instructions LORO direct balcony drains with connecting sleeve, EN 123-compliant, Steel, hot-dip galvanised, additionally coated, and DN 100 System overview for balcony storeys one-piece for upper balconies

More information

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein. SECTION 10530 - EXTRUDED ALUMINUM WALKWAY COVERS PART I - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division

More information

ACO Building Drainage

ACO Building Drainage ACO Building Drainage Backflow systems Installation, Operation and Maintenance Manual ACO TRIPLEX Anti-flood valve for GREYWATER drainage (wastewater without sewage) PLEASE READ THESE INSTRUCTIONS BEFORE

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal

More information

Brackett Green CF100 and CF200 Band Screens

Brackett Green CF100 and CF200 Band Screens Brackett Green CF100 and CF200 Band Screens Advanced water screening Key features & benefits Excellent pretreatment for MBR High performance 2 dimensional screening Patented Propapanel technology prevents

More information

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING

More information

Wavin: Range 600 Inspection Chambers

Wavin: Range 600 Inspection Chambers Uniclass EPIC G632:G581 JR12 CI/SfB (52.7) In6 August 2013 WP004 J34 Wavin: Range 600 Inspection Chambers Product Technical Guide Solutions for Essentials Contents Foul water Surface water Indicates where

More information

Drainage and Erosion Control

Drainage and Erosion Control Drainage and Erosion Control Erosion Control To order Straw Waddle 020897 Straw Waddle 9" x 25 Roll 14 Rolls/ None 140209 Wood Stakes 1" x 2" x 18" 50 Pcs./Bndl. None Straw fiber rolls that control erosion

More information

TECHNICAL SPECIFICATION DANTECO HERMANNS. CONTAINER FOR BULK POWDER Equipped with HERMANNS Aeration and Conveyance Device

TECHNICAL SPECIFICATION DANTECO HERMANNS. CONTAINER FOR BULK POWDER Equipped with HERMANNS Aeration and Conveyance Device TECHNICAL SPECIFICATION DANTECO HERMANNS CONTAINER FOR BULK POWDER Equipped with HERMANNS Aeration and Conveyance Device 6058(20') x 2438(8') x 2591(8'6") MODEL NO. : CX09-20SNX1 SPEC. NO : CX09-20SNX1-S3

More information

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

SECTION BASIC ELECTRICAL MATERIALS AND METHODS SECTION 26 05 05 BASIC ELECTRICAL MATERIALS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the limited scope construction materials and methods for application with electrical installations as follows:

More information

Liquid Roofing. Cold applied waterproofing systems for refurbishment and new build construction.

Liquid Roofing. Cold applied waterproofing systems for refurbishment and new build construction. Liquid Roofing Cold applied waterproofing systems for refurbishment and new build construction www.tor-coatings.com Liquid roofing is a technology unlike any other. It offers significant advantages over

More information

HAWLE-range of products

HAWLE-range of products HAWLE-pRODucTS All OvER ThE world since 1948 HAWLE-range of products HAWLE subsidiaries HAWLE partners Illustrations, technical data, dimensions and weights are subject to alteration without notice. Edition

More information

TI-LINE TILUX DURABASE. Borderless Shower Areas

TI-LINE TILUX DURABASE. Borderless Shower Areas TI-LINE TILUX DURABASE Borderless Shower Areas Borderless Shower Areas TI-LINE The patented linear drainage system that makes a perfect junction with walls. An overview of all the system s components along

More information

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

KeeGuard Foldshield Operation & Maintenance Manual

KeeGuard Foldshield Operation & Maintenance Manual S A F E T Y A T T H E H I G H E S T L E V E L KeeGuard Foldshield Operation & Maintenance Manual 2 KeeGuard System Overview SAFETY GUARDRAIL SYSTEMS The Company s guardrail system KEEGUARD has been designed

More information

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms. PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Underground Exhaust System

Underground Exhaust System Operation and Maintenance Manual Underground Exhaust MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 Underground Duct Construction Standards 1. Dig trench depth to allow for minimum distance from

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 07 40 00 Roofing 1. General Several factors repeatedly show up during the inspection of roofs that have failed prematurely. They include inappropriate use of materials, poor drainage systems, poor details

More information

SECTION SANITARY WASTE INTERCEPTORS

SECTION SANITARY WASTE INTERCEPTORS SECTION 22 13 23 SANITARY WASTE INTERCEPTORS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information