Selecting Cover Systems

Size: px
Start display at page:

Download "Selecting Cover Systems"

Transcription

1 Selecting Cover Systems Construction Specialties offers a wide variety of expansion joint covers for every joint size, movement requirement and finish material you may encounter. Selecting the proper cover for your application may not be as easy as you think and can be a high liability if not done properly. A lot of thought has to be put into the selection process regardless if it s a 36 seismic joint or a 1 thermal joint. The majority of product failures are caused by not understanding the movement requirements resulting in improper sizing of the joint and an incorrect product selection. Following is a brief summary of how to size the joints properly and what to consider when selecting the joint cover. We encourage you (even challenge you if that s what it takes) to contact us if you have any questions at all. We can help you size the joints properly and select the right products, which will lower your risk and reduce the liability to all of us. Step 1: Understand the movement requirements The most important part of selecting the proper expansion joint cover is to understand the movement requirements. Confusion is caused when manufacturers convey movement in different ways. Example: A manufacturer might specify the movement for the joint cover as each direction and list the requirement as a 4 joint that allows for 2 movement. This means that the 4 joint will open to 6 and close to 2 (2 in each direction ). Example: Another manufacturer might list the movement for their joint cover as total movement and specify a 4 joint as allowing for 4 movement. This also means that the 4 joint will open to 6 and close to 2 (2 each way for a 4 total movement ). Each manufacturer means the same thing but each is literally describing the allowable movement in totally different ways. In order to understand the movement correctly we need to deal with such terms such as nominal, minimum and maximum: o Nominal width is the size of the joint before any movement takes place. o The minimum is the width of the joint when it has reached its maximum closing potential. o The maximum is the width of the joint when it has reached its maximum opening potential. We recommend that when the engineer tells you the joint width, you ask them for the minimum and maximum dimensions at full movement. The structural engineer will indicate the location of the joints and the joint width needed for movement. Experience tells us that the width provided by the engineer is typically the movement needed and is not necessarily the joint width required for the covers and/or fire barrier systems. Example: if the engineer states that a 2 joint is required, they expect it to open to 4 and close to 0. If they tell you that you need a 12 joint, they expect it to open to 24 and close to 0. Our goal with this manual is to avoid the confusion; therefore, we have listed the movement for all models in minimum and maximum dimensions. (Note that the minimum dimensions are for the covers only and do not take into consideration fire barriers that might be required for rated conditions. The minimum dimensions shown will be different for rated conditions.) To download detail, specs & photos visit For technical and design assistance call

2 Other types of movement that also have to be accommodated on certain jobs are lateral shear, vertical shear and wind sway: o Lateral shear refers to the movement of slabs in different directions parallel to the line of the joint. o Vertical shear is usually the result of settlement between the buildings. o Wind sway is engineered into taller buildings and can result in a significant amount of movement. Step 2: Sizing the joints properly Once the movement requirements are understood, the joints can be sized properly to accommodate the expansion joint covers. Most joint covers have components that take up space in the joint opening and rated floor and wall conditions will require fire barrier. These materials will not allow a joint to close to 0 without damaging the system or surrounding construction. Thus, you (architect/contractor) and I (manufacturer) need to size the joint accordingly to meet the movement requirements and accommodate the desired joint cover systems. Example: Say that you have selected our GTR as the style of cover you like for a floor joint. The engineer has told you that you need a 2 joint that has a 0 minimum and 4 maximum at full movement. GTR-200 might be your first thought for the 2 joint required by the engineer. But if you refer to the movement chart, you find that the GTR-200 does not meet the movement requirements. The joint must actually be increased to 4 wide (using GTR-400) to meet the movement requirements set forth by the engineer. It is important to let the engineer know that we have increased the joint size to allow for the covers to ensure that the structural and architectural drawings match. As you continue up in the building, it s not uncommon for joint sizes to increase on each floor (with the roof having the largest joints). Changing sizes on the interior joints is acceptable, but we may make recommendations to group certain floors together in order to reduce the number of different sizes required. Exterior joints should always be the same size from the roof to the ground. Joint size changes on the exterior results in unsightly transitions and difficulties in maintaining weather protection. Expansion joints must pass through the structure from top to bottom and front to back. If the joint appears to end abruptly within a building, be sure to consult the engineer for clarification. Step 3: Consider Joint Locations & Application Requirements When selecting cover systems, it is important to consider their location. For instance, will the joint cover be located in a hidden area or in a highly visible area (such as a lobby), where aesthetics are more important? Usage and location are also important. Will the joint cover be exposed to heavy rolling loads or will it only be exposed to foot traffic? Is hygiene a factor? Could the collection of dirt in the cover system create problems? It is critical to select the appropriate cover type for the intended application. For instance, "heavy duty" covers for heavier rolling loads, flush gasketed covers for "hygienic" or healthcare applications, and covers designed for wet areas. Generally, the floor cover application is the element most affected by usage and application. It is recommended that the selection process begin with the floor cover and progress from there. Step 4: Identify Adjacent Surface Finishes Form and function have often been in conflict with the design and use of expansion joint cover systems. Improvements in function have often come at the expense of aesthetics, and vice versa. For example, trying to conceal expansion joint covers with surface finish in-lays often led to thicker joint cover assemblies. These thicker assemblies resulted in obstacles for wheeled equipment. As technology and joint cover design improved, it became possible to conceal wider cover plates without affecting their functionality. Today, a wide variety of joint cover systems are available to meet form and function requirements. When selecting expansion joint cover systems, consideration should be given to the adjacent floor and wall finishes. Most finishes can be integrated into the cover assembly for maximum harmony with the surrounding design elements.

3 Section 1 - Floor Covers Joint Size Page Nos. Joint Size Page Nos. Gasketed Infill Metal Single Gasket Heavy Duty, Lower Accepts Thicker Movement Floor Finishes Double Gasket Tamper Resistant 1" to 2" 2" to 4" 5" to 16" 2" to 7" 8" to 16" 1" to 4" 1" to 4" ( ) ( ) ( ) ( ) ( ) ( ) ( ) Metal Carpet Applications Surface Mounted Plate Surface Plate w/ Turnbar Flush No-Bump Heavy Duty 1" to 4" 1" to 9" 1" to 16" 1" to 6" 2" to 6" 1" to 8" 2" to 8" ( ) ( ) ( ) ( ) ( ) ( ) ( ) 1.1

4 Section 1 - Floor Covers In the floor section you will find many different types and styles of floor covers that are designed for different joint sizes, degrees of movement, loading requirements and finished flooring materials. In most cases, there is more than one option for any condition, which provides you with different aesthetic and adaptive results. Example: An elementary school project has a 4 joint in the floor with a finish of vinyl composition tile (VCT). Looking through the manual, you find both a metal and a gasketed option that fit your requirements. The gasketed cover appears to be the better option as it offers a recessed center plate that accepts a floor finish between the gaskets. Compared to a metal surface, the gasketed cover greatly reduces the exposed surface. However, you may want to stay away from gaskets because in this case kids, pencils, and gaskets don t mix. In this application, an aluminum system is virtually vandal proof and will require less maintenance over time. Generally, the floor cover is the element most affected by usage and application. We recommend that you begin the selection process with the floor cover and build from there. Gasketed Joint Covers Minimal exposed surface for simple expansion and contraction needs. Designed to eliminate bumps for applications where wheeled equipment is used. Easy to clean making them particularly suited for areas where hygiene is important. Vinyl gaskets have rigid edges to maximize hygienic seal. Vinyl gaskets are replaceable and are typically available in a variety of standard and custom colors to match adjacent finishes. Dual gasket models available with recessed center plate to accept surrounding flexible floor materials such as vinyl and carpet for maximum concealment. Infill Covers Capable of withstanding simple expansion and contraction as well as larger seismic movements. Employs a deeper pan capable of accommodating thicker or fragile floor finishes including ceramic tile, concrete, limestone or marble. For base-isolated building a hinged "moat" cover configuration of the pan is used. Custom engineered covers are available for joint sizes up to 48". Metal Joint Covers Typically more exposed and capable of accommodating simple expansion and contraction as well as larger seismic movements. Metal covers are durable enough for industrial applications. Tamper resistant for areas where security and vandalism is a concern. Metal standard covers are typically designed to withstand point loads of up to 500 lbs where metal heavy-duty covers can withstand up to 2000 lbs. Metal heavy-duty covers provide long term durability under heavy rolling loads or high volume areas. Custom engineered covers are available for joint sizes up to 48". 1.2

5 GFS & GFSW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: GFS / GFSW is a gasketed floor joint cover comprised of extruded aluminum frames and a TPR seal. The extruded aluminum floor frame is designed to provide a minimal bump in a surface-mounted application. Use This Cover For: Applications with small, interior joints where minimal visual impact is preferred. Suitable for all floor finishes. Where wheeled equipment is to be used. Where hygiene is important. 1 and 2 joints. Retrofit applications. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. 2" model includes aluminum support plate for added durability. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: No blockouts required. System attaches to surface of substrate by using mechanical fasteners. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

6 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GFS '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 4.31'' (109mm) N/A N/A GFS '' (51mm) 1.50'' (38mm) 2.50'' (64mm) 5.13'' (130mm) N/A N/A GFSW '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 2.66'' (68mm) N/A N/A GFSW '' (51mm) 1.50'' (38mm) 2.50'' (64mm) 3.56'' (90mm) N/A N/A FLEXIBLE GASKET EXPOSED SURFACE ALUMINUM FRAME SCHEDULED FLOOR FINISH FLEXIBLE GASKET ALUMINUM FRAME EXPOSED SURFACE ALUMINUM WALL FAME JOINT JOINT GFS-100 GFSW-100 EXPOSED SURFACE ALUMINUM FRAME EXPOSED SURFACE ALUMINUM FLOOR TO WALL FRAME JOINT ALUMINUM SUPPORT PLATE JOINT GFS-200 GFSW

7 GFPS & GFPSW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: GFPS / GFSPW is a gasketed floor joint cover comprised of extruded aluminum frames and a TPR seal. The extruded aluminum floor frame is designed to provide a minimal bump in a surfacemounted application and accept a carpet floor finish. Use This Cover For: Applications with small, interior joints where minimal visual impact is preferred. Suitable for carpet finishes. Where wheeled equipment is to be used. Where hygiene is important. 1 and 2 joints. Retrofit applications. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. 2" model includes aluminum support plate for added durability. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: No blockouts required. System attaches to surface of substrate by using mechanical fasteners. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

8 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GFPS '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.18'' (30mm) N/A N/A GFPS '' (51mm) 1.50'' (38mm) 2.50'' (64mm) 1.88'' (48mm) N/A N/A GFPSW '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.09'' (28mm) N/A N/A GFPSW '' (51mm) 1.50'' (38mm) 2.50'' (64mm) 1.94'' (49mm) N/A N/A EXPOSED SURFACE FLEXIBLE GASKET ALUMINUM FLOOR FRAME EXPOSED SURFACE FLEXIBLE GASKET ALUMINUM FLOOR FRAME ALUMINUM WALL FRAME JOINT JOINT GFPS-100 GFPSW-100 EXPOSED SURFACE ALUMINUM FRAME EXPOSED SURFACE ALUMINUM FRAME JOINT ALUMINUM SUPPORT PLATE JOINT ALUMINUM SUPPORT PLATE GFPS-200 GFPSW

9 GFST & GFSTW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A- T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: This single gasket, flush floor cover is ideal for applications of surface retrofit where floor tiles are used. Use This Cover For: Applications with small, interior joints where minimal visual impact is preferred. Suitable for most floor finishes. Where wheeled equipment is to be used. Where hygiene is important. 1 and 2 joints. Retrofit applications. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. 2" model includes aluminum support plate for added durability. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: No blockouts required. System attaches to surface of substrate by using mechanical fasteners. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

10 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GFST '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 4.31'' (109mm) N/A N/A GFST '' (51mm) 1.50'' (38mm) 2.50'' (64mm) 5.13'' (130mm) N/A N/A GFSTW '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 2.66'' (68mm) N/A N/A GFSTW '' (51mm) 1.50'' (38mm) 2.50'' (64mm) 3.56'' (90mm) N/A N/A FLEXIBLE GASKET EXPOSED SURFACE CONTINUOUS EXTRUDED ALUMINUM FRAME FLEXIBLE GASKET ALUMINUM FRAME EXPOSED SURFACE CONTINUOUS EXTRUDED ALUMINUM WALL FAME 1/8" JOINT JOINT GFST-100 GFSTW-100 FLEXIBLE GASKET EXPOSED SURFACE CONTINUOUS EXTRUDED ALUMINUM WALL FAME ALUMINUM FRAME EXPOSED SURFACE ALUMINUM FRAME JOINT ALUMINUM SUPPORT PLATE JOINT GFST-200 GFSTW

11 GFT & GFTW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A- T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: GFT / GFTW is a gasketed floor joint cover comprised of extruded aluminum frames and a TPR seal. The frames are available in heights of 1, 1-1/2, 2, and 3. Use This Cover For: Applications with small, interior joints where minimal visual impact is preferred. Suitable for most floor finishes. Frame depth and configuration is variable to suit selected finish. Where wheeled equipment is to be used. Where hygiene is important. 1 and 2 joints. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. 2" model includes aluminum support plate for added durability. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. The assembly will be attached to the slab with mechanical fasteners. The remaining space in the blockouts gets filled with a high strength, non-shrink (HSNS) grout. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

12 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GFT '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.25'' (32mm) 2.50'' (64mm) VARIES GFT '' (51mm) 1.50'' (38mm) 2.50'' (64mm) 1.88'' (48mm) 2.50'' (64mm) VARIES GFTW '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.13'' (29mm) 2.50'' (64mm) VARIES GFTW '' (51mm) 1.50'' (38mm) 2.50'' (64mm) 1.93'' (49mm) 2.50'' (64mm) VARIES EXPOSED SURFACE ALUMINUM WALL FRAME EXPOSED SURFACE FLEXIBLE GASKET FLEXIBLE GASKET HEIGHT HEIGHT ALUMINUM FRAME ALUMINUM ANCHOR FRAME JOINT 1" GFT-100 GFTW-100 ALUMINUM FRAME EXPOSED SURFACE EXPOSED SURFACE HEIGHT HEIGHT ALUMINUM FRAME HEIGHT JOINT JOINT GFT-200 GFTW

13 GFT-M Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A- T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: GFT-M is a gasketed floor joint cover for new to existing conditions comprised of extruded aluminum frames and a TPR seal. The frames are available in heights of 1, 1-1/2, 2, and 3. Use This Cover For: Applications with small, interior joints where minimal visual impact is preferred. Suitable for most floor finishes. Frame depth and configuration is variable to suit selected finish. Where wheeled equipment is to be used. Where hygiene is important. 1 and 2 joints. New to Existing conditions. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. 2" model includes aluminum support plate for added durability. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. The assembly will be attached to the slab with mechanical fasteners. The remaining space in the blockouts gets filled with a high strength, non-shrink (HSNS) grout. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

14 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GFT-100M 1.00'' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.25'' (32mm) 2.50'' (64mm) VARIES GFT-200M 2.00'' (51mm) 1.50'' (38mm) 2.50'' (64mm) 1.88'' (48mm) 2.50'' (64mm) VARIES EXPOSED SURFACE FLEXIBLE GASKET HEIGHT ALUMINUM FRAME ALUMINUM FRAME JOINT GFT-100M EXPOSED SURFACE HEIGHT ALUMINUM SUPPORT PLATE JOINT GFT-200M 1.12

15 GFT-B & GFTW-B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Bronze C38500 ASTM B455 Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: GFT-B / GFTW-B is a gasketed floor joint cover comprised of extruded aluminum frames with a bronze TIP and a TPR seal. The frames are available in heights of 1, 1-1/2, 2, and 3. Use This Cover For: Applications with small, interior joints where minimal visual impact is preferred. Suitable for most floor finishes. Frame depth and configuration is variable to suit selected finish. Where wheeled equipment is to be used. Where hygiene is important. 1 and 2 joints. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. 2" model includes aluminum support plate for added durability. Standard Finishes: Bronze finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. The assembly will be attached to the slab with mechanical fasteners. The remaining space in the blockouts gets filled with a high strength, non-shrink (HSNS) grout. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

16 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GFT-100B 1.00'' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.38'' (35mm) 2.50'' (64mm) VARIES GFT-200B 2.00'' (51mm) 1.50'' (38mm) 2.50'' (64mm) 2.18'' (55mm) 2.50'' (64mm) VARIES GFTW-100B 1.00'' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.25'' (32mm) 2.50'' (64mm) VARIES GFTW-200B 2.00'' (51mm) 1.50'' (38mm) 2.50'' (64mm) 2.00'' (51mm) 2.50'' (64mm) VARIES BRONZE FRAME CAP ALUM ADAPTOR EXPOSED SURFACE FLEXIBLE GAXKET EXPOSED SURFACE FLEXIBLE GAXKET BRONZE FRAME CAP ALUM ADAPTOR ALUMINUM WALL FRAME HEIGHT HEIGHT ALUMINUM ANCHOR LEG ALUMINUM ANCHOR LEG JOINT JOINT GFT-100B GFTW-100B ALUMINUM CENTER PLATE BRONZE FRAME CAP EXPOSED SURFACE FLEXIBLE GASKET ALUMINUM CAP ADAPTOR FLEXIBLE GASKET BRONZE FRAME CAP ALUMINUM CAP ADAPTOR EXPOSED SURFACE HEIGHT HEIGHT ALUMINUM WALL FRAME ALUMINUM ANCHOR LEG ALUMINUM ANCHOR LEG ALUMINUM CENTER PLATE JOINT JOINT GFT-200B GFTW-200B 1.14

17 GTP & GTPW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover is ideal for areas with larger movement requirements and where exposed metal center plate is desired. Use This Cover For: Applications where a flush cover is preferred. Where light wheeled equipment is to be used. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable, self-centering aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

18 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GTP '' (51mm) 1.25'' (32mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 0.63'' (16mm) GTP '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 0.63'' (16mm) GTP '' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 0.63'' (16mm) GTPW '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 0.63'' (16mm) GTPW '' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.63'' (16mm) GTPW '' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 0.63'' (16mm) ALUMINUM FRAME EXPOSED SURFACE ALUMINUM TURNBAR ASSEMBLY CENTER PLATE HEIGHT HEIGHT JOINT GTP (TYP.) EXPOSED SURFACE HEIGHT ALUMINUM COVER PLATE JOINT GTPW (TYP.) 1.16

19 GTP-M Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: This gasketed flush floor cover is ideal for new to existing conditions, and where exposed metal center plate is desired. Use This Cover For: Applications where a flush cover is preferred. Where light wheeled equipment is to be used. Where hygiene is important. New to Existing conditions. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Durable aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach new frame in blockout and existing frame to face of slab with C/S supplied fasteners. Attach cover plate and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

20 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GTP-200M 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 0.63'' (16mm) GTP-300M 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.63'' (16mm) GTP-400M 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 0.63'' (16mm) FLEXIBLE GASKET EXPOSED SURFACE ALUM. CENTER PLATE FACTORY CUT FLOOR FINISH (OPTIONAL) HEIGHT ALUMINUM FRAME ALUMINUM LEDGE FRAME JOINT GTP-M (TYP.) 1.18

21 GTP-HD & GTPW-HD Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 2,000 lbs. Product Description: This dual gasket, flush floor cover is ideal for areas where heavy rolling loads will occur and where there are larger movement requirements. Use This Cover For: Applications with larger movement requirements and where a flush cover is preferred. Where heavy wheeled equipment is to be used. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. The softer center section of the gasket allows full movement. The heavy-duty gaskets are closed cell extrusions capable of heavier loads than traditional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable, self-centering aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

22 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GTP-200HD 2.00'' (51mm) 1.25'' (32mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 0.63'' (16mm) GTP-300HD 3.00'' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 0.63'' (16mm) GTP-400HD 4.00'' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 0.63'' (16mm) GTPW-200HD 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 0.63'' (16mm) GTPW-300HD 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.63'' (16mm) GTPW-400HD 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 0.63'' (16mm) ALUMINUM FRAME HEIGHT EXPOSED SURFACE TURNBAR ASSEMBLY ALUMINUM CENTER PLATE HEIGHT JOINT GTP-HD (TYP.) EXPOSED SURFACE HEIGHT ALUMINUM CENTER PLATE JOINT GTPW-HD (TYP.) 1.20

23 GTR & GTRW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover is ideal for areas with larger movement requirements and where a concealed cover is desired. Use This Cover For: Applications where a flush, concealed cover is preferred. Cover offers a 1/8 recessed center plate to accept carpet or vinyl flooring. Where light wheeled equipment is to be used. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable self-centering aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

24 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GTR '' (51mm) 1.25'' (32mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 0.63'' (16mm) GTR '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 0.63'' (16mm) GTR '' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 0.63'' (16mm) GTRW '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 0.63'' (16mm) GTRW '' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.63'' (16mm) GTRW '' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 0.63'' (16mm) ALUMINUM FRAME TURNBAR ASSEMBLY EXPOSED SURFACE RECESSED ALUMINUM CENTER PLATE HEIGHT HEIGHT JOINT GTR (TYP.) HEIGHT EXPOSED SURFACE RECESSED ALUMINUM COVER PLATE JOINT GTRW (TYP.) 1.22

25 GTR-M Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: This gasketed, flush floor cover is ideal for new to existing conditions, and where a concealed cover is desired. Use This Cover For: Applications where a flush, concealed cover is preferred. Cover offers a 1/8 recessed center plate to accept carpet or vinyl flooring. Where light wheeled equipment is to be used. Where hygiene is important. New to Existing conditions. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Durable aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach new frame in blockout and existing frame to face of slab with C/S supplied fasteners. Attach cover plate and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

26 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GTR-200M 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 0.63'' (16mm) GTR-300M 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.63'' (16mm) GTR-400M 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 0.63'' (16mm) FLEXIBLE GASKET HEIGHT EXPOSED SURFACE (WITHOUT FLOOR FINISH) ALUM. CENTER PLATE FACTORY CUT FLOOR FINIS ALUMINUM FRAME ALUMINUM LEDGE FRAME JOINT GTR-M (TYP.) 1.24

27 GTR-S & GTRW-S Series GTR-B & GTRW-B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Bronze C28000 Muntz Metal ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover is ideal for areas with larger movement requirements and where a bronze or stainless finish is desired. Use This Cover For: Applications where a flush cover is preferred. Cover offers a 1/8 recessed center plate to accept bronze or stainless insert. Where light wheeled equipment is to be used. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable self-centering aluminum plate spans joint opening. Standard Finishes: Stainless Steel No. 4 finish. Bronze Satin finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

28 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GTR-200S/B 2.00'' (51mm) 1.25'' (32mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 0.63'' (16mm) GTR-300S/B 3.00'' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 0.63'' (16mm) GTR-400S/B 4.00'' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 0.63'' (16mm) GTRW-200S/B 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 0.63'' (16mm) GTRW-300S/B 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.63'' (16mm) GTRW-400S/B 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 0.63'' (16mm) STAINLESS STEEL OR BRONZE INSERT ALUM. CENTER PLATE FLEXIBLE GASKET EXPOSED SURFACE FLOOR FINISH (OPTIONAL) HEIGHT ALUM. FRAME TURNBAR JOINT GTR-S/B (TYP.) STAINLESS STEEL OR BRONZE INSERT FLEXIBLE GASKET EXPOSED SURFACE ALUMINUM FRAME JOINT ALUMINUM CENTER PLATE GTRW-S/B (TYP.) 1.26

29 GTR-D & GTRW-D Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover is ideal for areas with larger movement requirements and where a concealed cover is desired. The cover plate has a deep recess that allows for thicker floor finish materials (up to 3/8 thick). Use This Cover For: Applications where a flush, concealed cover is preferred. Cover offers a 3/8 recessed center plate to accept carpet or vinyl flooring (Tile or other brittle finish not recommended). Where light wheeled equipment is to be used. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable, self-centering aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

30 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GTR-200D 2.00'' (51mm) 1.25'' (32mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 0.63'' (16mm) GTR-300D 3.00'' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 0.63'' (16mm) GTR-400D 4.00'' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 0.63'' (16mm) GTRW-200D 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 0.63'' (16mm) GTRW-300D 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.63'' (16mm) GTRW-400D 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 0.63'' (16mm) EXPOSED SURFACE ALUMINUM FRAME TURNBAR ASSEMBLY DEEP RECESSED CENTER PLATE HEIGHT HEIGHT JOINT GTR-D (TYP.) EXPOSED SURFACE HEIGHT DEEP RECESSED COVER PLATE JOINT GTRW-D (TYP.) 1.28

31 GTR-DM Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: This gasketed, flush floor cover is ideal for new to existing conditions and where a concealed cover is desired. The cover plate has a deep recess that allows for thicker floor finish materials (up to 3/8 thick). Use This Cover For: Applications where a flush, concealed cover is preferred. Cover offers a 3/8 recessed center plate to accept carpet or vinyl flooring (Tile or other brittle finish not recommended). Where light wheeled equipment is to be used. Where hygiene is important. New to Existing conditions. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Durable aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach new frame in blockout and existing frame to face of slab with C/S supplied fasteners. Attach cover plate and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

32 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GTR-200DM 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 0.63'' (16mm) GTR-300DM 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.63'' (16mm) GTR-400DM 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 0.63'' (16mm) FLEXIBLE GASKET HEIGHT EXPOSED SURFACE ALUM. CENTER PLATE FACTORY CUT FLOOR FINISH (OPTIONAL) ALUMINUM FRAME ALUMINUM LEDGE FRAME JOINT GTR-DM (TYP.) 1.30

33 DGTP & DGTPW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover uses a deep extruded aluminum base frame and is ideal for areas with larger movement requirements and where exposed metal center plate is desired. Use This Cover For: Applications where a flush cover is preferred. Where light wheeled equipment is to be used. Where hygiene is important. Deep frame allows for more construction tolerance than shallow frames. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable, self-centering aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

34 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT DGTP '' (51mm) 1'' (25mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 1.19'' (30mm) DGTP '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 1.19'' (30mm) DGTP '' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 1.19'' (30mm) DGTPW '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 1.19'' (30mm) DGTPW '' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 1.19'' (30mm) DGTPW '' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 1.19'' (30mm) FLEXIBLE GASKET EXPOSED SURFACE ALUM. CENTER PLATE HEIGHT HEIGHT ALUM. FRAME JOINT TURNBAR ASSEMBLY DGTP (TYP.) EXPOSED SURFACE HEIGHT JOINT DGTPW (TYP.) 1.32

35 DGTP-M Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: This gasketed, flush floor cover uses a deep extruded aluminum base frame and is ideal for new to existing conditions, and where exposed metal center plate is desired. Use This Cover For: Applications where a flush cover is preferred. Where light wheeled equipment is to be used. Where hygiene is important. New to Existing conditions. Deep frame allows for more construction tolerance than shallow frames. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Durable, aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach new frame in blockout and existing frame to face of slab with C/S supplied fasteners. Attach cover plate and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

36 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT DGTP-200M 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 1.19'' (30mm) DGTP-300M 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 1.19'' (30mm) DGTP-400M 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 1.19'' (30mm) FLEXIBLE GASKET EXPOSED SURFACE ALUM. CENTER PLATE FACTORY CUT HEIGHT CONTINUOUS EXTRUDED ALUMINUM FRAME JOINT ALUMINUM LEDGE FRAME DGTP-M (TYP.) 1.34

37 DGTP-HD & DGTPW-HD Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61)Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 2,000 lbs. Product Description: This dual gasket, flush floor cover uses a deep extruded aluminum base frame and is ideal for areas where heavy rolling loads will occur and where there are larger movement requirements. Use This Cover For: Applications with larger movement requirements and where a flush, cover is preferred. Where heavy wheeled equipment is to be used. Where hygiene is important. Deep frame allows for more construction tolerance than shallow frames. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. The softer center section of the gasket allows full movement. The heavy-duty gaskets are closed cell extrusions capable of heavier loads than traditional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable, self-centering aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

38 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT DGTP-200HD 2.00'' (51mm) 1.00'' (25mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 1.19'' (30mm) DGTP-300HD 3.00'' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 1.19'' (30mm) DGTP-400HD 4.00'' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 1.19'' (30mm) DGTPW-200HD 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 1.19'' (30mm) DGTPW-300HD 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 1.19'' (30mm) DGTPW-400HD 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 1.19'' (30mm) EXPOSED SURFACE HEIGHT HEIGHT JOINT DGTP-HD (TYP.) EXPOSED SURFACE HEIGHT JOINT DGTPW-HD (TYP.) 1.36

39 DGTR & DGTRW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover uses a deep extruded aluminum base frame and is ideal for areas with larger movement requirements and where a concealed cover is desired. Use This Cover For: Applications where a flush, concealed cover is preferred. Cover offers a 1/8 recessed center plate to accept carpet or vinyl flooring. Where light wheeled equipment is to be used. Where hygiene is important. Deep frame allows for more construction tolerance than shallow frames. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable self-centering aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

40 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT DGTR '' (51mm) 1.00'' (25mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 1.19'' (30mm) DGTR '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 1.19'' (30mm) DGTR '' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 1.19'' (30mm) DGTRW '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 1.19'' (30mm) DGTRW '' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 1.19'' (30mm) DGTRW '' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 1.19'' (30mm) FLEXIBLE GASKET EXPOSED SURFACE FLOOR FINISH ALUM. CENTER PLATE HEIGHT HEIGHT ALUM. FRAME JOINT TURNBAR DGTR (TYP.) EXPOSED SURFACE HEIGHT JOINT DGTRW (TYP.) 1.38

41 DGTR-M Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: This gasketed, flush floor cover uses a deep extruded aluminum base frame and is ideal for new to existing conditions and where a concealed cover is desired. Use This Cover For: Applications where a flush, concealed cover is preferred. Cover offers a 1/8 recessed center plate to accept carpet or vinyl flooring. Where light wheeled equipment is to be used. Where hygiene is important. New to Existing conditions. Deep frame allows for more construction tolerance than shallow frames. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Durable aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach new frame in blockout and existing frame to face of slab with C/S supplied fasteners. Attach cover plate and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

42 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT DGTR-200M 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 1.19'' (30mm) DGTR-300M 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 1.19'' (30mm) DGTR-400M 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 1.19'' (30mm) RECESSED ALUMINUM COVER PLATE FLEXIBLE GASKET EXPOSED SURFACE HEIGHT JOINT DGTR-M (TYP.) 1.40

43 DGTR-S & DGTRW-S Series DGTR-B & DGTRW-B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Bronze C28000 Muntz Metal ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover uses a deep extruded aluminum base frame and is ideal for areas with larger movement requirements and where a bronze or stainless finish is desired. Use This Cover For: Applications where a flush cover is preferred. Cover offers a 1/8 recessed center plate to accept bronze or stainless insert. Where light wheeled equipment is to be used. Where hygiene is important. Deep frame allows for more construction tolerance than shallow frames. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable self-centering aluminum plate spans joint opening. Standard Finishes: Bronze Satin finish. Stainless No.4 finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

44 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT DGTR-200S/B 2.00'' (51mm) 1.00'' (25mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 1.19'' (30mm) DGTR-300S/B 3.00'' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 1.19'' (30mm) DGTR-400S/B 4.00'' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 1.19'' (30mm) DGTRW-200S/B 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 1.19'' (30mm) DGTRW-300S/B 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 1.19'' (30mm) DGTRW-400S/B 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 1.19'' (30mm) STAINLESS STEEL OR BRONZE INSERT EXPOSED SURFACE ALUM. CENTER PLATE FLEXIBLE GASKET HEIGHT FLOOR FINISH (OPTIONAL) ALUM. FRAME TURNBAR JOINT DGTR-S/B (TYP.) EXPOSED SURFACE STAINLESS STEEL OR BRONZE INSERT FLEXIBLE GASKET HEIGHT ALUM. FRAME JOINT DGTRW-S/B (TYP.) 1.42

45 DGTR-D & DGTRW-D Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover uses a deep extruded aluminum base frame and is ideal for areas with larger movement requirements and where a concealed cover is desired. The cover plate has a deep recess that allows for thicker floor finish materials (up to 3/8 thick). Use This Cover For: Applications where a flush, concealed cover is preferred. Cover offers a 3/8 recessed center plate to accept carpet or vinyl flooring (Tile or other brittle finishes not recommended). Where light wheeled equipment is to be used. Where hygiene is important. Deep frame allows for more construction tolerance than shallow frames. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable, self-centering aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach frames in blockout with C/S supplied screws. Slide in turnbars and align with holes in cover plate. Screw cover plate into turnbars and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

46 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT DGTR-200D 2.00'' (51mm) 1.00'' (25mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 1.19'' (30mm) DGTR-300D 3.00'' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 1.19'' (30mm) DGTR-400D 4.00'' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 1.19'' (30mm) DGTRW-200D 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 1.19'' (30mm) DGTRW-300D 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 1.19'' (30mm) DGTRW-400D 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 1.19'' (30mm) DEEP RECESSED ALUMINUM COVER PLATE FLEXIBLE GASKET EXPOSED SURFACE HEIGHT HEIGHT JOINT DGTR-D (TYP.) EXPOSED SURFACE DEEP RECESSED ALUMINUM COVER PLATE FLEXIBLE GASKET HEIGHT JOINT DGTRW-D (TYP.) 1.44

47 DGTR-DM Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Standard Loading 500 lbs. Product Description: This gasketed, flush floor cover uses a deep extruded aluminum base frame and is ideal for new to existing conditions and where a concealed cover is desired. The cover plate has a deep recess that allows for thicker floor finish materials (up to 3/8 thick). Use This Cover For: Applications where a flush, concealed cover is preferred. Cover offers a 3/8 recessed center plate to accept carpet or vinyl flooring (Tile or other brittle finishes not recommended). Where light wheeled equipment is to be used. Where hygiene is important. New to Existing conditions. Deep frame allows for more construction tolerance than shallow frames. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Durable aluminum plate spans joint opening. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. Attach new frame in blockout and existing frame to face of slab with C/S supplied fasteners. Attach cover plate and insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

48 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT DGTR-200DM 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 1.19'' (30mm) DGTR-300DM 3.00'' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 1.19'' (30mm) DGTR-400DM 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 1.19'' (30mm) EXPOSED SURFACE DEEP RECESSED ALUMINUM COVER PLATE FLEXIBLE GASKET NEW TO EXISTING ALUMINUM RETAINER HEIGHT JOINT DGTR-DM (TYP.) 1.46

49 SGP & SGPW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Material 1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover is ideal for areas with larger movement requirements and where a exposed metal center plate is desired. The joint can be designed for up to 100% movement. Use This Cover For: Seismic interior applications requiring a completely flush joint cover. Where wheeled equipment is to be used. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable aluminum plate spans joint opening. This model also features a self-centering or turnbar device to keep the plate centered during seismic cycling. This unique movement design also incorporates a deflector, or seismic policeman on the bottom side of the center plate. As the joint closes during seismic cycling, deflectors come into contact with the side frames, and the plate is elevated in order to prevent damage. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. It is recommended that the block-out be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the block-outs to provide a continuous, solid, flat and level base for the joint cover. (Note: The block-outs must be level across the joint opening.) Install base frames with C/S supplied fasteners. Fasten cover plate to frames with turnbar. Insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

50 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SGP '' (127mm) 2.50'' (64mm) 9.00'' (229mm) 12.00'' (305mm) 3.50'' (89mm) 0.75'' (19mm) SGP '' (152mm) 2.75'' (70mm) 9.00'' (229mm) 13.00'' (330mm) 3.50'' (89mm) 0.75'' (19mm) SGP '' (178mm) 2.75'' (70mm) 12.25'' (311mm) 15.00'' (381mm) 4.00'' (102mm) 0.75'' (19mm) SGP '' (203mm) 2.75'' (70mm) 13.25'' (337mm) 16.00'' (406mm) 4.00'' (102mm) 0.75'' (19mm) SGP '' (229mm) 2.75'' (70mm) 14.25'' (362mm) 18.00'' (457mm) 4.50'' (114mm) 0.75'' (19mm) SGP '' (254mm) 2.75'' (70mm) 16.25'' (413mm) 19.00'' (483mm) 4.50'' (114mm) 0.75'' (19mm) SGP '' (279mm) 2.75'' (70mm) 18.25'' (464mm) 21.00'' (533mm) 5.00'' (127mm) 0.75'' (19mm) SGP '' (305mm) 2.75'' (70mm) 18.50'' (470mm) 22.00'' (559mm) 5.00'' (127mm) 0.75'' (19mm) SGP '' (330mm) 2.75'' (70mm) 21.25'' (540mm) 24.00'' (610mm) 5.50'' (140mm) 0.75'' (19mm) SGP '' (356mm) 2.75'' (70mm) 22.25'' (565mm) 25.00'' (635mm) 5.50'' (140mm) 0.75'' (19mm) SGP '' (381mm) 2.75'' (70mm) 23.00'' (584mm) 27.00'' (686mm) 6.00'' (152mm) 0.75'' (19mm) SGP '' (406mm) 2.75'' (70mm) 25.25'' (641mm) 28.00'' (711mm) 6.00'' (152mm) 0.75'' (19mm) SGPW '' (127mm) 4.25'' (108mm) 7.75'' (197mm) 8.50'' (216mm) 3.50'' (89mm) 0.75'' (19mm) SGPW '' (152mm) 4.25'' (108mm) 7.75'' (197mm) 9.50'' (241mm) 3.50'' (89mm) 0.75'' (19mm) SGPW '' (178mm) 5.00'' (127mm) 9.50'' (241mm) 11.00'' (279mm) 4.00'' (102mm) 0.75'' (19mm) SGPW '' (203mm) 5.50'' (140mm) 10.50'' (267mm) 12.00'' (305mm) 4.00'' (102mm) 0.75'' (19mm) SGPW '' (229mm) 6.00'' (152mm) 11.50'' (292mm) 13.50'' (343mm) 4.50'' (114mm) 0.75'' (19mm) SGPW '' (254mm) 6.50'' (165mm) 13.00'' (330mm) 14.50'' (368mm) 4.50'' (114mm) 0.75'' (19mm) SGPW '' (279mm) 7.00'' (178mm) 14.50'' (368mm) 16.00'' (406mm) 5.00'' (127mm) 0.75'' (19mm) SGPW '' (305mm) 7.50'' (191mm) 15.25'' (387mm) 17.00'' (432mm) 5.00'' (127mm) 0.75'' (19mm) SGPW '' (330mm) 8.00'' (203mm) 17.00'' (432mm) 18.50'' (470mm) 5.50'' (140mm) 0.75'' (19mm) SGPW '' (356mm) 8.50'' (216mm) 18.00'' (457mm) 19.50'' (495mm) 5.50'' (140mm) 0.75'' (19mm) SGPW '' (381mm) 9.00'' (229mm) 19.00'' (483mm) 21.00'' (533mm) 6.00'' (152mm) 0.75'' (19mm) SGPW '' (406mm) 9.50'' (241mm) 20.50'' (521mm) 22.00'' (559mm) 6.00'' (152mm) 0.75'' (19mm) Call factory for joints larger than 16 EXPOSED SURFACE HEIGHT HEIGHT JOINT SGP (TYP.) EXPOSED SURFACE HEIGHT JOINT SGPW (TYP.) 1.48

51 SGR & SGRW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Material -C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover is ideal for areas with larger movement requirements and where a concealed cover is desired. The joint can be designed for up to 100% movement. Use This Cover For: Seismic interior applications requiring a completely flush joint cover virtually concealed in the surrounding floor finishes. Cover offers a 1/8 recessed center plate to accept carpet or vinyl flooring. Where wheeled equipment is to be used. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable aluminum plate spans joint opening. This model also features a self-centering or turnbar device to keep the plate centered during seismic cycling. This unique movement design also incorporates a deflector, or seismic policeman on the bottom side of the center plate. As the joint closes during seismic cycling, deflectors come into contact with the side frames, and the plate is elevated in order to prevent damage. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Fasten cover plate to frames with turnbar. Insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

52 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SGR '' (127mm) 2.50'' (64mm) 9.25'' (235mm) 12.00'' (305mm) 3.50'' (89mm) 0.75'' (19mm) SGR '' (152mm) 2.75'' (70mm) 9.50'' (241mm) 13.00'' (330mm) 3.50'' (89mm) 0.75'' (19mm) SGR '' (178mm) 2.75'' (70mm) 12.25'' (311mm) 15.00'' (381mm) 4.00'' (102mm) 0.75'' (19mm) SGR '' (203mm) 2.75'' (70mm) 13.25'' (337mm) 16.00'' (406mm) 4.00'' (102mm) 0.75'' (19mm) SGR '' (229mm) 2.75'' (70mm) 14.25'' (362mm) 18.00'' (457mm) 4.50'' (114mm) 0.75'' (19mm) SGR '' (254mm) 2.75'' (70mm) 16.25'' (413mm) 19.00'' (483mm) 4.50'' (114mm) 0.75'' (19mm) SGR '' (279mm) 2.75'' (70mm) 18.25'' (464mm) 21.00'' (533mm) 5.00'' (127mm) 0.75'' (19mm) SGR '' (305mm) 2.75'' (70mm) 18.50'' (470mm) 22.00'' (559mm) 5.00'' (127mm) 0.75'' (19mm) SGR '' (330mm) 2.75'' (70mm) 21.25'' (540mm) 24.00'' (610mm) 5.50'' (140mm) 0.75'' (19mm) SGR '' (356mm) 2.75'' (70mm) 22.25'' (565mm) 25.00'' (635mm) 5.50'' (140mm) 0.75'' (19mm) SGR '' (381mm) 2.75'' (70mm) 23.00'' (584mm) 27.00'' (686mm) 6.00'' (152mm) 0.75'' (19mm) SGR '' (406mm) 2.75'' (70mm) 25.25'' (641mm) 28.00'' (711mm) 6.00'' (152mm) 0.75'' (19mm) SGRW '' (127mm) 4.25'' (108mm) 7.75'' (197mm) 8.50'' (216mm) 3.50'' (89mm) 0.75'' (19mm) SGRW '' (152mm) 4.25'' (108mm) 7.75'' (197mm) 9.50'' (241mm) 3.50'' (89mm) 0.75'' (19mm) SGRW '' (178mm) 5.00'' (127mm) 9.50'' (241mm) 11.00'' (279mm) 4.00'' (102mm) 0.75'' (19mm) SGRW '' (203mm) 5.50'' (140mm) 10.50'' (267mm) 12.00'' (305mm) 4.00'' (102mm) 0.75'' (19mm) SGRW '' (229mm) 6.00'' (152mm) 11.50'' (292mm) 13.50'' (343mm) 4.50'' (114mm) 0.75'' (19mm) SGRW '' (254mm) 6.50'' (165mm) 13.00'' (330mm) 14.50'' (368mm) 4.50'' (114mm) 0.75'' (19mm) SGRW '' (279mm) 7.00'' (178mm) 14.50'' (368mm) 16.00'' (406mm) 5.00'' (127mm) 0.75'' (19mm) SGRW '' (305mm) 7.50'' (191mm) 15.25'' (387mm) 17.00'' (432mm) 5.00'' (127mm) 0.75'' (19mm) SGRW '' (330mm) 8.00'' (203mm) 17.00'' (432mm) 18.50'' (470mm) 5.50'' (140mm) 0.75'' (19mm) SGRW '' (356mm) 8.50'' (216mm) 18.00'' (457mm) 19.50'' (495mm) 5.50'' (140mm) 0.75'' (19mm) SGRW '' (381mm) 9.00'' (229mm) 19.00'' (483mm) 21.00'' (533mm) 6.00'' (152mm) 0.75'' (19mm) SGRW '' (406mm) 9.50'' (241mm) 20.50'' (521mm) 22.00'' (559mm) 6.00'' (152mm) 0.75'' (19mm) Call factory for joints larger than 16 ALUMINUM FRAME HEIGHT TURNBAR ASSEMBLY EXPOSED SUFACE CENTER PLATE ASSEMBLY BL H JOINT SGR (TYP.) HEIGHT EXPOSED SURFACE ALUMINUM CENTER PLATE ASSEMBLY JOINT SGRW (TYP.) 1.50

53 SGR S/B & SGRW S/B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Bronze C28000 Muntz Metal ASTM B455. Stainless Steel Type 304 ASTM A167, A240A, A240M Primary Seal. Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000. Available in 4 colors. Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Standard Loading 500 lbs. Product Description: This dual gasket, flush floor cover is ideal for areas with larger movement requirements and where a bronze or stainless steel finish is desired. The joint can be designed for up to 100% movement. Use This Cover For: Seismic interior applications requiring a completely flush joint cover virtually concealed in the surrounding floor finishes. Cover offers a 1/8 recessed center plate to accept bronze or stainless steel finish. Where wheeled equipment is to be used. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. The rigid edges also prevent the gasket from being cut by heavy rolling loads that tend to destroy conventional gaskets. Dual gaskets allow for greater expansion and compression during movement. Durable aluminum plate spans joint opening. This model also features a self-centering or turnbar device to keep the plate centered during seismic cycling. This unique movement design also incorporates a deflector, or seismic policeman on the bottom side of the center plate. As the joint closes during seismic cycling, deflectors come into contact with the side frames, and the plate is elevated in order to prevent damage. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Bronze Satin finish. Stainless Steel No. 4 finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. Depth may be adjusted as needed to accommodate a floor finish material when required. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Fasten cover plate to frames with turnbar. Insert gaskets. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

54 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SGR-500 S/B 5.00'' (127mm) 2.50'' (64mm) 9.25'' (235mm) 12.00'' (305mm) 3.50'' (89mm) 0.75'' (19mm) SGR-600 S/B 6.00'' (152mm) 2.75'' (70mm) 9.50'' (241mm) 13.00'' (330mm) 3.50'' (89mm) 0.75'' (19mm) SGR-700 S/B 7.00'' (178mm) 2.75'' (70mm) 12.25'' (311mm) 15.00'' (381mm) 4.00'' (102mm) 0.75'' (19mm) SGR-800 S/B 8.00'' (203mm) 2.75'' (70mm) 13.25'' (337mm) 16.00'' (406mm) 4.00'' (102mm) 0.75'' (19mm) SGR-900 S/B 9.00'' (229mm) 2.75'' (70mm) 14.25'' (362mm) 18.00'' (457mm) 4.50'' (114mm) 0.75'' (19mm) SGR-1000 S/B 10.00'' (254mm) 2.75'' (70mm) 16.25'' (413mm) 19.00'' (483mm) 4.50'' (114mm) 0.75'' (19mm) SGR-1100 S/B 11.00'' (279mm) 2.75'' (70mm) 18.25'' (464mm) 21.00'' (533mm) 5.00'' (127mm) 0.75'' (19mm) SGR-1200 S/B 12.00'' (305mm) 2.75'' (70mm) 18.50'' (470mm) 22.00'' (559mm) 5.00'' (127mm) 0.75'' (19mm) SGR-1300 S/B 13.00'' (330mm) 2.75'' (70mm) 21.25'' (540mm) 24.00'' (610mm) 5.50'' (140mm) 0.75'' (19mm) SGR-1400 S/B 14.00'' (356mm) 2.75'' (70mm) 22.25'' (565mm) 25.00'' (635mm) 5.50'' (140mm) 0.75'' (19mm) SGR-1500 S/B 15.00'' (381mm) 2.75'' (70mm) 23.00'' (584mm) 27.00'' (686mm) 6.00'' (152mm) 0.75'' (19mm) SGR-1600 S/B 16.00'' (406mm) 2.75'' (70mm) 25.25'' (641mm) 28.00'' (711mm) 6.00'' (152mm) 0.75'' (19mm) SGRW-500 S/B 5.00'' (127mm) 4.25'' (108mm) 7.75'' (197mm) 8.50'' (216mm) 3.50'' (89mm) 0.75'' (19mm) SGRW-600 S/B 6.00'' (152mm) 4.25'' (108mm) 7.75'' (197mm) 9.50'' (241mm) 3.50'' (89mm) 0.75'' (19mm) SGRW-700 S/B 7.00'' (178mm) 5.00'' (127mm) 9.50'' (241mm) 11.00'' (279mm) 4.00'' (102mm) 0.75'' (19mm) SGRW-800 S/B 8.00'' (203mm) 5.50'' (140mm) 10.50'' (267mm) 12.00'' (305mm) 4.00'' (102mm) 0.75'' (19mm) SGRW-900 S/B 9.00'' (229mm) 6.00'' (152mm) 11.50'' (292mm) 13.50'' (343mm) 4.50'' (114mm) 0.75'' (19mm) SGRW-1000 S/B 10.00'' (254mm) 6.50'' (165mm) 13.00'' (330mm) 14.50'' (368mm) 4.50'' (114mm) 0.75'' (19mm) SGRW-1100 S/B 11.00'' (279mm) 7.00'' (178mm) 14.50'' (368mm) 16.00'' (406mm) 5.00'' (127mm) 0.75'' (19mm) SGRW-1200 S/B 12.00'' (305mm) 7.50'' (191mm) 15.25'' (387mm) 17.00'' (432mm) 5.00'' (127mm) 0.75'' (19mm) SGRW-1300 S/B 13.00'' (330mm) 8.00'' (203mm) 17.00'' (432mm) 18.50'' (470mm) 5.50'' (140mm) 0.75'' (19mm) SGRW-1400 S/B 14.00'' (356mm) 8.50'' (216mm) 18.00'' (457mm) 19.50'' (495mm) 5.50'' (140mm) 0.75'' (19mm) SGRW-1500 S/B 15.00'' (381mm) 9.00'' (229mm) 19.00'' (483mm) 21.00'' (533mm) 6.00'' (152mm) 0.75'' (19mm) SGRW-1600 S/B 16.00'' (406mm) 9.50'' (241mm) 20.50'' (521mm) 22.00'' (559mm) 6.00'' (152mm) 0.75'' (19mm) Call factory for joints larger than 16 EXPOSED SURFACE ALUMINUM ADAPTER WELDED TO CENTER PLATE 1/8" ST. STEEL OR BRONZE INSERT FLEXIBLE GASKET HEIGHT HEIGHT ALUMINUM FRAME 3/16" ALUMINUM CENTER PLATE TURN BAR ASSEMBLY JOINT SGR- S/B (TYP.) ALUM. PLATE ADAPTERS WELDED TO CENTER PLATE FLEXIBLE GASKET EXPOSED SURFACE 1/8" ST. STEEL OR BRONZE INSERT 3/16" ALUMINUM CENTER PLATE ALUMINUM FRAME TURN BAR ASSEMBLY ALUMINUM WALL FRAME EXTRUDED HINGE TRACK FILLET WELDED TO CENTER PLATE JOINT SGRW- S/B (TYP.) 1.52

55 SSR 200/700 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Turnbar Aluminum Tube Cast Stainless Steel Ends - Type 304 ASTM A167, A240A, A240M Standard Loading 500 lbs. Product Description: This flush floor cover is ideal where a concealed cover is desired. The cover plate has a deep recess that allows for thicker floor finish materials (1 thick). Use This Cover For: Interior and exterior seismic applications where cover concealment is desired in deeper floor finishes. Applications with floor finishes of up to 1" thick. Optional waterstop where weather integrity is important. Performance Characteristics: Caulk joints expand and contract for minor thermal movement. During seismic activity the center pan assembly lifts for additional movement and returns to normal position after event. Thermal movement will not make the center pan dislodge. Standard Finishes: Mill finish where aluminum is exposed. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the block-out be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the block-outs to provide a continuous, solid, flat and level base for the joint cover. (Note: The block-outs must be level across the joint opening.) Install base frames with C/S supplied fasteners. Attach center pan with turnbar into base frame. Apply backer rod & sealant where shown. For complete installation instructions, visit To download detail, specs & photos visit For technical and design assistance call

56 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SSR " (51mm) 0.75" (19mm) 4.00" (102mm) 13.81" (351mm) 7.69" (195mm) 2.00" (51mm) SSR " (76mm) 0.75" (19mm) 5.00" (127mm) 13.81" (351mm) 7.19" (183mm) 2.00" (51mm) SSR '' (102mm) 0.75" (19mm) 6.00" (152mm) 13.81" (351mm) 6.69" (170mm) 2.00" (51mm) SSR '' (127mm) 0.75" (19mm) 8.50" (191mm) 17.75" (452mm) 8.50" (203mm) 2.00" (51mm) SSR '' (152mm) 0.75" (19mm) 9.50" (216mm) 17.75" (452mm) 8.00" (191mm) 2.00" (51mm) SSR '' (178mm) 0.75" (19mm) 10.50" (267mm) 17.75" (452mm) 7.50" (178mm) 2.00" (51mm) ALUMINUM FRAME EXPOSED SURFACE ALUMINUM FRAME HEIGHT HEIGHT TURNBAR ASSEMBLY JOINT SSR- 200/

57 SSRH & SSRW 200/700 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 500 lbs. Product Description: This flush floor cover is ideal where a concealed cover is desired. The cover plate has a deep recess that allows for thicker floor finish materials (1 thick). Use This Cover For: Interior and exterior seismic applications where cover concealment is desired in deeper floor finishes. Applications with floor finishes of up to 1" thick. Optional waterstop where weather integrity is important. New to existing applications where there is no blockout in the existing slab Adjacent floor-to-floor wall covers so the visual alignment is continuous Performance Characteristics: Caulk joints expand and contract for minor thermal movement. During seismic activity the center pan assembly lifts for additional movement and returns to normal position after event. Thermal movement will not make the center pan dislodge. Standard Finishes: Mill finish where aluminum is exposed. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Attach center pan with turnbar or hinge into wall frame. Apply backer rod & sealant where shown. For complete installation instructions and sealant recommendations, visit To download detail, specs & photos visit For technical and design assistance call

58 MODEL JOINT MINIMUM MAXIMUM EXPOSED SLIDING SIDE SLIDING SIDE HINGE SIDE HINGE SIDE OPENING OPENING SURFACE WID. HGT. WID. HGT. SSRH '' (51mm) 0.00'' (0mm) 6.00'' (152mm) 9.81'' (249mm) 9.00'' (229mm) 2.00'' (51mm) 3.50'' (89mm) 2.00'' (51mm) SSRH '' (76mm) 0.00'' (0mm) 6.00'' (152mm) 9.81'' (249mm) 8.00'' (203mm) 2.00'' (51mm) 3.50'' (89mm) 2.00'' (51mm) SSRH '' (102mm) 0.00'' (0mm) 6.00'' (152mm) 9.81'' (249mm) 7.00'' (178mm) 2.00'' (51mm) 3.50'' (89mm) 2.00'' (51mm) SSRH '' (127mm) 0.00'' (0mm) 12.00'' (305mm) 15.81'' (402mm) 12.00'' (305mm) 2.00'' (51mm) 3.50'' (89mm) 2.00'' (51mm) SSRH '' (152mm) 0.00'' (0mm) 12.00'' (305mm) 15.81'' (402mm) 11.00'' (279mm) 2.00'' (51mm) 3.50'' (89mm) 2.00'' (51mm) SSRH '' (178mm) 0.00'' (0mm) 12.00'' (305mm) 15.81'' (402mm) 10.00'' (254mm) 2.00'' (51mm) 3.50'' (89mm) 2.00'' (51mm) SSRW '' (51mm) 1.00'' (25mm) 6.00'' (152mm) 9.25'' (235mm) 9.00'' (229mm) 2.00'' (51mm) N/A N/A SSRW '' (76mm) 1.00'' (25mm) 6.00'' (152mm) 9.25'' (235mm) 8.00'' (203mm) 2.00'' (51mm) N/A N/A SSRW '' (102mm) 1.00'' (25mm) 6.00'' (152mm) 9.25'' (235mm) 7.00'' (178mm) 2.00'' (51mm) N/A N/A SSRW '' (127mm) 1.00'' (25mm) 12.00'' (305mm) 15.25'' (387mm) 12.00'' (305mm) 2.00'' (51mm) N/A N/A SSRW '' (152mm) 1.00'' (25mm) 12.00'' (305mm) 15.25'' (387mm) 11.00'' (279mm) 2.00'' (51mm) N/A N/A SSRW '' (178mm) 1.00'' (25mm) 12.00'' (305mm) 15.25'' (387mm) 10.00'' (254mm) 2.00'' (51mm) N/A N/A ALUMINUM FRAME EXPOSED SURFACE ALUMINUM FRAME ALUMINUM FRAME HEIGHT HEIGHT JOINT 3-1/2" SSRH (TYP.) EXPOSED SURFACE ALUMINUM FRAME ALUMINUM FRAME HEIGHT ALUMINUM FRAME JOINT SSRW 200/

59 SSR & SSRW 800/1600 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Turnbar Steel channel Standard Loading 500 lbs. Product Description: This flush floor cover is ideal where a concealed cover is desired. The cover plate has a deep recess that allows for thicker floor finish materials (1-1/2 thick). Use This Cover For: Interior and exterior seismic applications where cover concealment is desired in deeper floor finishes. Applications with floor finishes of up to 1-1/2" thick. Heavy-duty versions available for limited vehicular access. Optional waterstop where weather integrity is important. Performance Characteristics: Caulk joints expand and contract for minor thermal movement. During seismic activity the center pan assembly lifts for additional movement and returns to normal position after event. Thermal movement will not make the center pan dislodge. Standard Finishes: Mill finish where aluminum is exposed. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the block-out be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the block-outs to provide a continuous, solid, flat and level base for the joint cover. (Note: The block-outs must be level across the joint opening.) Install base frames with C/S supplied fasteners. Attach center pan with turnbar or hinge into wall frame. Apply backer rod & sealant where shown. For complete installation instructions and sealant recommendations, visit To download detail, specs & photos visit For technical and design assistance call

60 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SSR '' (203mm) 2.25'' (57mm) 13.00'' (330mm) 20.75'' (527mm) 7.88'' (200mm) 2.50'' (64mm) SSR '' (229mm) 2.25'' (57mm) 14.50'' (368mm) 22.25'' (572mm) 8.13'' (206mm) 2.50'' (64mm) SSR '' (254mm) 2.25'' (57mm) 16.00'' (406mm) 23.75'' (603mm) 8.38'' (213mm) 2.50'' (64mm) SSR '' (279mm) 2.25'' (57mm) 17.50'' (445mm) 25.25'' (641mm) 8.63'' (219mm) 2.50'' (64mm) SSR '' (305mm) 2.25'' (57mm) 19.00'' (483mm) 26.75'' (679mm) 8.88'' (225mm) 2.50'' (64mm) SSR '' (330mm) 2.25'' (57mm) 20.50'' (521mm) 28.25'' (718mm) 9.13'' (232mm) 2.50'' (64mm) SSR '' (356mm) 2.25'' (57mm) 22.00'' (559mm) 29.75'' (756mm) 9.38'' (238mm) 2.50'' (64mm) SSR '' (381mm) 2.25'' (57mm) 23.50'' (597mm) 31.25'' (794mm) 9.63'' (244mm) 2.50'' (64mm) SSR '' (406mm) 2.25'' (57mm) 25.00'' (635mm) 32.75'' (832mm) 9.88'' (251mm) 2.50'' (64mm) SSRW '' (203mm) 3.00'' (76mm) 10.50'' (267mm) 14.38'' (365mm) 7.88'' (200mm) 2.50'' (64mm) SSRW '' (229mm) 3.00'' (76mm) 11.75'' (298mm) 15.63'' (397mm) 8.13'' (206mm) 2.50'' (64mm) SSRW '' (254mm) 3.00'' (76mm) 13.00'' (330mm) 16.88'' (429mm) 8.38'' (213mm) 2.50'' (64mm) SSRW '' (279mm) 3.00'' (76mm) 14.25'' (362mm) 18.13'' (460mm) 8.63'' (219mm) 2.50'' (64mm) SSRW '' (305mm) 3.00'' (76mm) 15.50'' (394mm) 19.38'' (492mm) 8.88'' (225mm) 2.50'' (64mm) SSRW '' (330mm) 3.00'' (76mm) 16.75'' (425mm) 20.63'' (524mm) 9.13'' (232mm) 2.50'' (64mm) SSRW '' (356mm) 3.00'' (76mm) 18.00'' (457mm) 21.88'' (556mm) 9.38'' (238mm) 2.50'' (64mm) SSRW '' (381mm) 3.00'' (76mm) 19.25'' (489mm) 23.13'' (587mm) 9.63'' (244mm) 2.50'' (64mm) SSRW '' (406mm) 3.00'' (76mm) 20.50'' (521mm) 24.38'' (619mm) 9.88'' (251mm) 2.50'' (64mm) EXPOSED SURFACE INSTALLED CENTER PLATE ASSEMBLY TURNBAR ASSEMBLY HEIGHT HEIGHT JOINT SSR- 800/1600 EXPOSED SURFACE CONT. EXTRUDED ALUMINUM BASE FRAME CONT. EXTRUDED ALUMINUM MODULAR PLATE CONT. EXTRUDED ALUMINUM HINGE NOSING HEIGHT CONT. EXTRUDED ALUMINUM HINGE FRAME JOINT SSRW- 800/

61 APF and APFW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 2,200 lbs. Product Description: This all metal cover is highly resistant to rolling loads, distortion, and wear. Maintains a virtually flush finish ideal for heavy rolling equipment. The frames are available in heights of 1/2, 1 1 1/2 and 2. Use This Cover For: Applications with heavy rolling loads such as: Forklifts with full or pneumatic tires of a permissible total weight equal to 15,700 lbs. (tire adhesion area 7.88 x 7.88 ). Trucks with pneumatic tires of a permissible total weight equal to 67,400 lbs. Vehicles and goods handling trucks with tires of hard plastics. The permissible load dependant on tire width is lbs. per every mm of a tire width. Performance Characteristics: The unique interlocking cover design allows for horizontal movement in the floor slab, as well as some vertical deflection, and is designed to withstand heavy and frequent rolling loads. This system is also ideal for areas where significant foot traffic is expected such as malls and airports and is considered extremely low maintenance. The interlocking cover assembly utilizes precision gaskets to eliminate any metal-to-metal noise and to prevent the infiltration of liquids. Standard Finishes: Mill finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover it is recommended the cover be leveled on a high strength, nonshrink epoxy bed. The cover assembly is delivered in a fixed position/width through the use of shipping straps engineered for the specific movement criteria of the project. Center the assembly over the joint opening and fasten in place with supplied mechanical fasteners. Remove shipping strap after attachment. Fill blockout area with high strength non-shrink (HSNS) grout and apply floor finish as required. To download detail, specs & photos visit For technical and design assistance call

62 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT APF '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.70'' (43mm) 4.00'' (102mm) VARIES APF '' (51mm) 1.63'' (41mm) 2.38'' (60mm) 3.30'' (84mm) 4.00'' (102mm) VARIES APF '' (76mm) 2.50'' (64mm) 3.50'' (89mm) 4.37'' (111mm) 4.00'' (102mm) VARIES APF '' (102mm) 3.25'' (83mm) 4.75'' (121mm) 5.28'' (134mm) 4.00'' (102mm) VARIES APFW '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.70'' (43mm) 4.00'' (102mm) VARIES APFW '' (51mm) 1.63'' (41mm) 2.38'' (60mm) 3.30'' (84mm) 4.00'' (102mm) VARIES APFW '' (76mm) 2.50'' (64mm) 3.50'' (89mm) 4.37'' (111mm) 4.00'' (102mm) VARIES APFW '' (102mm) 3.25'' (83mm) 4.75'' (121mm) 5.28'' (134mm) 4.00'' (102mm) VARIES ALUMINUMCOVER PLATE EXPOSED SURFACE ALUMINUM COVER PLATE INSERT ALUMINUM FRAME HEIGHT HEIGHT JOINT APF (TYP.) ALUMINUM COVER PLATE INSERT FLEXIBLE GASKET FLOOR FINISH EXPOSED SURFACE ALUMINUM COVER PLATE ALUMINUM WALL FRAME HEIGHT JOINT APFW (TYP.) 1.60

63 ALS & ALSW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 500 lbs. Product Description: This all metal cover is ideal where low maintenance is desirable and for tamper-proof applications. Serrated side plates create a more flush finish but impact visibility. Use This Cover For: Applications where low maintenance is desirable or for tamper-proof applications. Suitable for most floor finishes. Optional waterstop available for wet areas. Performance Characteristics: Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Standard Finishes: Mill finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Set center plate over frames and snap cover plates into base frames. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

64 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ALS '' (25mm) 0.00'' (0mm) 2.25'' (57mm) 5.00'' (127mm) 2.00'' (51mm) 1.00'' (25mm) ALS '' (51mm) 0.00'' (0mm) 4.00'' (102mm) 7.75'' (197mm) 2.88'' (73mm) 1.00'' (25mm) ALS '' (76mm) 0.88'' (22mm) 6.00'' (152mm) 10.75'' (273mm) 3.88'' (98mm) 1.00'' (25mm) ALS '' (102mm) 0.88'' (22mm) 7.00'' (178mm) 11.75'' (298mm) 3.88'' (98mm) 1.00'' (25mm) ALSW '' (25mm) 0.50'' (13mm) 1.69'' (43mm) 3.00'' (76mm) 2.00'' (51mm) 1.00'' (25mm) ALSW '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.88'' (124mm) 2.88'' (73mm) 1.00'' (25mm) ALSW '' (76mm) 1.44'' (37mm) 4.56'' (116mm) 6.88'' (175mm) 3.88'' (98mm) 1.00'' (25mm) ALSW '' (102mm) 2.44'' (62mm) 5.50'' (140mm) 7.88'' (200mm) 3.88'' (98mm) 1.00'' (25mm) ALUMINUM SERRATED COVER PLATE EXPOSED SURFACE HEIGHT HEIGHT JOINT ALUMINUM FRAME ALS (TYP.) EXPOSED SURFACE ALUMINUM SERRATED COVER PLATE HEIGHT JOINT ALUMINUM FLOOR TO WALL FRAME ALSW (TYP.) 1.62

65 ALS-S & ALSW-S Series ALS-B & ALSW-B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Bronze C28000 Muntz Metal ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Standard Loading 500 lbs. Product Description: This all metal cover is ideal for interior applications where low maintenance and a bronze or stainless steel finish is desirable. Use This Cover For: Interior applications where low maintenance is desirable. Suitable for most floor finishes. Optional waterstop available for wet areas. Performance Characteristics: Free-floating center plate spans joint and slides between frame assemblies to allow movement when required. Standard Finishes: Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Bronze Satin finish. Stainless Steel No. 4 finish. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Set center plate over frames and snap cover plates into base frames. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

66 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ALS-100 S/B 1.00'' (25mm) 0.00'' (0mm) 2.25'' (57mm) 5.00'' (127mm) 2.00'' (51mm) 1.00'' (25mm) ALS-200 S/B 2.00'' (51mm) 0.00'' (0mm) 4.00'' (102mm) 7.75'' (197mm) 2.88'' (73mm) 1.00'' (25mm) ALS-300 S/B 3.00'' (76mm) 0.88'' (22mm) 6.00'' (152mm) 10.75'' (273mm) 3.88'' (98mm) 1.00'' (25mm) ALS-400 S/B 4.00'' (102mm) 0.88'' (22mm) 7.00'' (178mm) 11.75'' (298mm) 3.88'' (98mm) 1.00'' (25mm) ALSW-100 S/B 1.00'' (25mm) 0.50'' (13mm) 1.69'' (43mm) 3.00'' (76mm) 2.00'' (51mm) 1.00'' (25mm) ALSW-200 S/B 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.88'' (124mm) 2.88'' (73mm) 1.00'' (25mm) ALSW-300 S/B 3.00'' (76mm) 1.44'' (37mm) 4.56'' (116mm) 6.88'' (175mm) 3.88'' (98mm) 1.00'' (25mm) ALSW-400 S/B 4.00'' (102mm) 2.44'' (62mm) 5.50'' (140mm) 7.88'' (200mm) 3.88'' (98mm) 1.00'' (25mm) EXPOSED SURFACE ST. STEEL OR BRONZE BAR STOCK, FACTORY WELDED TO BOTTOM OF PLATE ST. STEEL OR BRONZE CENTER PLATE ST. STEEL OR BRONZE SERRATED COVER PLATE HEIGHT BASE FRAME JOINT ALS-S/B (TYP.) ST. STEEL OR BRONZE SERRATED COVER PLATE EXPOSED SURFACE ST. STEEL OR BRONZE ANGLE HEIGHT BASE FRAME ST. STEEL OR BRONZE CENTER PLATE JOINT ALSW-S/B (TYP.) 1.64

67 ALS-M Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 500 lbs. Product Description: This all metal cover is ideal for new to existing conditions, where low maintenance is desirable, and for tamper-resistant applications. Serrated side plates create a more flush finish but impact visibility. Use This Cover For: Applications where low maintenance is desirable or for tamper-resistant applications. Suitable for most floor finishes. Optional waterstop available for wet areas. New to Existing conditions. Performance Characteristics: Center plate attached to hinge style frame on one side, spans joint and slides between frame assemblies to allow movement when required. Standard Finishes: Mill finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Install surface mounted frame on existing side. Hinge center plate into existing frame and snap cover plate into base frame. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

68 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ALS-100M 1.00'' (25mm) 0.50'' (13mm) 1.63'' (41mm) 5.00'' (127mm) 2.00'' (51mm) 1.00'' (25mm) ALS-200M 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 6.88'' (175mm) 2.88'' (73mm) 1.00'' (25mm) ALS-300M 3.00'' (76mm) 1.75'' (44mm) 4.75'' (121mm) 8.88'' (225mm) 3.88'' (98mm) 1.00'' (25mm) ALS-400M 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 9.88'' (251mm) 3.88'' (98mm) 1.00'' (25mm) ALUMINUM SERRATED PLATE HEIGHT EXPOSED SURFACE ALUMINUM FLOOR TO WALL COVER PLATE ALUMINUM NEW TO EXISTING SERRATED PLATE ALUMINUM FRAME JOINT EXISTING FLOOR ALS-M (TYP.) 1.66

69 ALR & ALRW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 500 lbs. Product Description: This metal floor cover is designed for interior applications where low maintenance or tamper-resistant applications are desirable. With recessed side frames, this model helps reduce visual impact as compared to other metal floor covers. Use This Cover For: Interior applications where low maintenance is desirable or for tamper-resistant applications. Suitable for most floor finishes. Optional waterstop available for wet areas. Performance Characteristics: Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Standard Finishes: Mill finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Set center plate over frames and snap cover plates into base frames. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

70 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ALR '' (25mm) 0.00'' (0mm) 2.25'' (57mm) 2.65'' (67mm) 2.00'' (51mm) 1.00'' (25mm) ALR '' (51mm) 0.00'' (0mm) 4.00'' (102mm) 3.65'' (93mm) 2.88'' (73mm) 1.00'' (25mm) ALR '' (76mm) 0.88'' (22mm) 6.00'' (152mm) 5.44'' (138mm) 3.88'' (98mm) 1.00'' (25mm) ALR '' (102mm) 0.88'' (22mm) 7.00'' (178mm) 6.44'' (164mm) 3.88'' (98mm) 1.00'' (25mm) ALRW '' (25mm) 0.50'' (13mm) 1.69'' (43mm) 1.81'' (46mm) 2.00'' (51mm) 1.00'' (25mm) ALRW '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 2.81'' (71mm) 2.88'' (73mm) 1.00'' (25mm) ALRW '' (76mm) 1.44'' (37mm) 4.56'' (116mm) 4.19'' (106mm) 3.88'' (98mm) 1.00'' (25mm) ALRW '' (102mm) 2.44'' (62mm) 5.50'' (140mm) 5.19'' (132mm) 3.88'' (98mm) 1.00'' (25mm) FINISHED FLOOR EXPOSED SURFACE ALUMINUM CENTER PLATE ALUMINUM COVER PLATE HEIGHT HEIGHT JOINT ALR (TYP.) FINISH FLOOR EXPOSED SURFACE HEIGHT ALUMINUM FLOOR TO WALL FRAME JOINT ALRW (TYP.) 1.68

71 ALR-M Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 500 lbs. Product Description: This metal floor cover is designed for new to existing interior applications where low maintenance or tamper-resistant applications are desirable. With recessed side frames, this model helps reduce visual impact as compared to other metal floor covers. Use This Cover For: Interior applications where low maintenance is desirable or for tamper-resistant applications. Suitable for most floor finishes. Optional waterstop available for wet areas. New to Existing conditions. Performance Characteristics: Center plate attached to hinge style frame on one side, spans joint and slides between frame assemblies to allow movement when required. Standard Finishes: Mill finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Install surface mounted frame on existing side. Hinge center plate into existing frame and snap cover plate into base frame. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

72 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ALR-100M 1.00'' (25mm) 0.50'' (13mm) 1.63'' (41mm) 3.81'' (97mm) 2.00'' (51mm) 1.00'' (25mm) ALR-200M 2.00'' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.81'' (122mm) 2.88'' (73mm) 1.00'' (25mm) ALR-300M 3.00'' (76mm) 1.75'' (44mm) 4.75'' (121mm) 6.19'' (157mm) 3.88'' (98mm) 1.00'' (25mm) ALR-400M 4.00'' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.19'' (183mm) 3.88'' (98mm) 1.00'' (25mm) HEIGHT EXPOSED SURFACE NEW TO EXISTING ALUMINUM FRAME JOINT ALR-M (TYP.) 1.70

73 AL-HD & ALW-HD Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 2,000 lbs. Product Description: This metal floor cover is designed for applications where low maintenance is desirable and heavy-duty rolling loads are expected. Use This Cover For: Applications where low maintenance is desirable Heavy-duty expansion joint applications. Suitable for most floor finishes. Optional waterstop available for wet areas. Performance Characteristics: Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Standard Finishes: Mill finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Set center plate over frames and screw cover plates into base frames. It is recommended that polystyrene block and sealant (by others) be installed to help seal the edges at the blockout. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

74 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT AL-100HD 1.00'' (25mm) 0.00'' (0mm) 2.00'' (51mm) 6.25'' (159mm) 2.88'' (73mm) 1.00'' (25mm) AL-200HD 2.00'' (51mm) 0.00'' (0mm) 4.00'' (102mm) 9.00'' (229mm) 3.75'' (95mm) 1.00'' (25mm) AL-300HD 3.00'' (76mm) 0.25'' (6mm) 5.75'' (146mm) 12.50'' (318mm) 5.00'' (127mm) 1.00'' (25mm) AL-400HD 4.00'' (102mm) 1.25'' (32mm) 6.75'' (171mm) 12.50'' (318mm) 4.50'' (114mm) 1.00'' (25mm) ALW-100HD 1.00'' (25mm) 0.63'' (16mm) 1.63'' (41mm) 3.63'' (92mm) 2.88'' (73mm) 1.00'' (25mm) ALW-200HD 2.00'' (51mm) 0.88'' (22mm) 3.13'' (79mm) 5.50'' (140mm) 3.75'' (95mm) 1.00'' (25mm) ALW-300HD 3.00'' (76mm) 1.13'' (29mm) 4.13'' (105mm) 7.75'' (197mm) 5.00'' (127mm) 1.00'' (25mm) ALW-400HD 4.00'' (102mm) 2.13'' (54mm) 5.13'' (130mm) 8.25'' (210mm) 4.50'' (114mm) 1.00'' (25mm) ALUMINUM SERRATED COVER PLATE EXPOSED SURFACE HEIGHT JOINT ALUMINUM FRAME AL-HD (TYP.) EXPOSED SURFACE ALUMINUM SERRATED COVER PLATE HEIGHT JOINT ALUMINUM FLOOR TO WALL FRAME ALW-HD (TYP.) 1.72

75 AL-HDM Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 2,000 lbs. Product Description: This metal floor cover is designed for new to existing applications where low maintenance is desirable and heavy-duty rolling loads are expected. Use This Cover For: Applications where low maintenance is desirable. Heavy-duty expansion joint applications. Suitable for most floor finishes. Optional waterstop available for wet areas. New to Existing conditions. Performance Characteristics: Center plate attached to hinge style frame on one side, spans joint and slides between frame assemblies to allow movement when required. Standard Finishes: Mill finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Install surface mounted frame on existing side. Hinge center plate into existing frame and screw cover plate into base frame. It is recommended that polystyrene block and sealant (by others) be installed to help seal the edges at the blockout. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

76 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT AL-100HDM 1.00'' (25mm) 0.13'' (3mm) 2.25'' (57mm) 8.75'' (222mm) 4.75'' (121mm) 0.75'' (19mm) AL-200HDM 2.00'' (51mm) 0.63'' (16mm) 3.25'' (83mm) 9.25'' (235mm) 4.25'' (108mm) 0.75'' (19mm) AL-300HDM 3.00'' (76mm) 1.50'' (38mm) 4.38'' (111mm) 10.25'' (260mm) 4.25'' (108mm) 0.75'' (19mm) AL-400HDM 4.00'' (102mm) 2.50'' (64mm) 5.38'' (137mm) 11.25'' (286mm) 4.25'' (108mm) 0.75'' (19mm) HEIGHT EXPOSED SURFACE NEW TO EXISTING ALUMINUM FRAME JOINT AL-HDM (TYP.) 1.74

77 FYW & FYWW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 500 lbs. Product Description: This metal floor cover is designed for interior applications where low maintenance or tamper-resistant applications are desirable. With a recessed side frame and sloped center plate, this model helps reduce visual impact as compared to other metal floor covers. Use This Cover For: Interior applications where low maintenance is desirable or for tamper-resistant applications. Cover offers a 1/8 recess to allow for carpet finishes. Optional vapor barrier available for wet areas. Performance Characteristics: Center plate attached to hinge style frame on one side spans joint and slides between frame assemblies to allow movement when required. Standard Finishes: Mill finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Hinge center plate in frame and screw cover plate into base frame. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

78 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FYW '' (25mm) 0.00'' (0mm) 2.13'' (54mm) 0.90'' (23mm) 3.88'' (99mm) 1.00'' (25mm) FYW '' (51mm) 1.00'' (25mm) 3.13'' (79mm) 0.90'' (23mm) 2.88'' (73mm) 1.00'' (25mm) FYW '' (76mm) 1.00'' (25mm) 5.13'' (130mm) 0.90'' (23mm) 6.13'' (156mm) 1.00'' (25mm) FYW '' (102mm) 2.00'' (51mm) 6.13'' (156mm) 0.90'' (23mm) 5.13'' (130mm) 1.00'' (25mm) FYWW '' (25mm) 0.38'' (10mm) 2.38'' (60mm) 0.90'' (23mm) 3.88'' (99mm) 1.00'' (25mm) FYWW '' (51mm) 1.38'' (35mm) 3.38'' (86mm) 0.90'' (23mm) 2.88'' (73mm) 1.00'' (25mm) FYWW '' (76mm) 1.38'' (35mm) 5.50'' (140mm) 0.90'' (23mm) 6.13'' (156mm) 1.00'' (25mm) FYWW '' (102mm) 2.38'' (60mm) 6.50'' (165mm) 0.90'' (23mm) 5.13'' (130mm) 1.00'' (25mm) 1/8" RECESS COVER FRAME EXPOSED SURFACE CENTER PLATE HEIGHT 1" (25mm) JOINT FYW (TYP.) 2" (51mm) CENTER PLATE 1/8" RECESS COVER FRAME EXPOSED SURFACE HEIGHT JOINT FYWW (TYP.) 1.76

79 FYW-D & FYWW-D Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Standard Loading 500 lbs. Product Description: This metal floor cover is designed for interior applications where low maintenance or tamper-resistant applications are desirable. With a recessed side frame and sloped center plate, this model helps reduce visual impact as compared to other metal floor covers. Use This Cover For: Interior applications where low maintenance is desirable or for tamper-resistant applications. Cover offers a 1/4 recess to allow for carpet finishes. Optional vapor barrier available for wet areas. Performance Characteristics: Center plate attached to hinge style frame on one side, spans joint and slides between frame assemblies to allow movement when required. Standard Finishes: Mill finish. Aluminum in contact with concrete/masonry will have a 2 mil heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Hinge center plate in frame and screw cover plate into base frame. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

80 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FYW-100D 1.00'' (25mm) 0.00'' (0mm) 2.13'' (54mm) 0.96'' (24mm) 3.88'' (98mm) 1.00'' (25mm) FYW-200D 2.00'' (51mm) 1.00'' (25mm) 3.13'' (79mm) 0.96'' (24mm) 2.88'' (73mm) 1.00'' (25mm) FYW-300D 3.00'' (76mm) 1.00'' (25mm) 5.13'' (130mm) 0.96'' (24mm) 6.13'' (156mm) 1.00'' (25mm) FYW-400D 4.00'' (102mm) 2.00'' (51mm) 6.13'' (156mm) 0.96'' (24mm) 5.13'' (130mm) 1.00'' (25mm) FYWW-100D 1.00'' (25mm) 0.38'' (10mm) 2.38'' (60mm) 0.96'' (24mm) 3.88'' (98mm) 1.00'' (25mm) FYWW-200D 2.00'' (51mm) 1.38'' (35mm) 3.38'' (86mm) 0.96'' (24mm) 2.88'' (73mm) 1.00'' (25mm) FYWW-300D 3.00'' (76mm) 1.38'' (35mm) 5.50'' (140mm) 0.96'' (24mm) 6.13'' (156mm) 1.00'' (25mm) FYWW-400D 4.00'' (102mm) 2.38'' (60mm) 6.50'' (165mm) 0.96'' (24mm) 5.13'' (130mm) 1.00'' (25mm) 1/4" RECESS COVER FRAME EXPOSED SURFACE CENTER PLATE HEIGHT 1" (25mm) JOINT 2" (51mm) FYW-D (TYP.) 1/4" RECESS COVER FRAME EXPOSED SURFACE HEIGHT JOINT FYWW-D (TYP.) 1.78

81 PC & PCW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Standard Loading 500 lbs. Product Description: This metal floor cover is designed for simple applications and is surface mounted over floor finishes. Custom widths and heavy duty versions are available. Use This Cover For: Applications where low maintenance is desirable. Simple floor cover solution without complex functionality. Simple installation with no moving parts or blockout requirements. Retrofit applications Performance Characteristics: Single plate design is anchored to only one slab allowing movement over the adjacent slab. Standard Finishes: Extruded plates clear anodized (1 4 models). Formed plates mill finish (5 & larger models). Installation Guidelines: Cover plate is secured to floor using mechanical fasteners. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

82 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT PC '' (25mm) 0.00'' (0mm) 2.25'' (57mm) 3.75'' (95mm) N/A N/A PC '' (51mm) 0.00'' (0mm) 3.75'' (95mm) 5.25'' (133mm) N/A N/A PC '' (76mm) 0.00'' (0mm) 5.25'' (133mm) 6.75'' (171mm) N/A N/A PC '' (102mm) 0.00'' (0mm) 6.75'' (171mm) 8.25'' (210mm) N/A N/A PC '' (127mm) 0.00'' (0mm) 8.25'' (210mm) 9.75'' (248mm) N/A N/A PC '' (152mm) 0.00'' (0mm) 9.75'' (248mm) 11.25'' (286mm) N/A N/A PC '' (178mm) 0.00'' (0mm) 11.25'' (286mm) 12.75'' (324mm) N/A N/A PC '' (203mm) 0.00'' (0mm) 12.75'' (324mm) 14.25'' (362mm) N/A N/A PC '' (229mm) 0.00'' (0mm) 14.25'' (362mm) 15.75'' (400mm) N/A N/A PCW '' (25mm) 0.00'' (0mm) 2.25'' (57mm) 2.25'' (57mm) N/A N/A PCW '' (51mm) 0.00'' (0mm) 3.75'' (95mm) 3.75'' (95mm) N/A N/A PCW '' (76mm) 0.00'' (0mm) 5.25'' (133mm) 5.25'' (133mm) N/A N/A PCW '' (102mm) 0.00'' (0mm) 6.75'' (171mm) 6.75'' (171mm) N/A N/A PCW '' (127mm) 0.00'' (0mm) 8.25'' (210mm) 8.25'' (210mm) N/A N/A PCW '' (152mm) 0.00'' (0mm) 9.75'' (248mm) 9.75'' (248mm) N/A N/A PCW '' (178mm) 0.00'' (0mm) 11.25'' (286mm) 11.25'' (286mm) N/A N/A PCW '' (203mm) 0.00'' (0mm) 12.75'' (324mm) 12.75'' (324mm) N/A N/A PCW '' (229mm) 0.00'' (0mm) 14.25'' (362mm) 13.75'' (349mm) N/A N/A Contact factory for larger sizes. EXPOSED SURFACE ALUMINUM COVER PLATE JOINT PC (TYP.) EXPOSED SURFACE ALUMINUM COVER PLATE JOINT PCW (TYP.) 1.80

83 PC-S / PC-B & PCW-S / PCW-B Series Technical Data: Bronze C28000 Muntz Metal ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Standard Loading 500 lbs. Product Description: This metal floor cover is designed for simple applications and surface mounted over floor finishes. Custom widths and heavy-duty are available. Use This Cover For: Applications where low maintenance is desirable. Simple floor cover solution without complex functionality. Simple installation with no moving parts or block-out requirements. Retrofit applications. Performance Characteristics: Single plate design is anchored to only one slab allowing movement over the adjacent slab. Standard Finishes: Stainless Steel No. 4 finish. Bronze Satin finish. Installation Guidelines: Cover plate is secured to floor using mechanical fasteners. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

84 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT PC-100 S/B 1.00'' (25mm) 0.00'' (0mm) 2.25'' (57mm) 3.75'' (95mm) N/A N/A PC-200 S/B 2.00'' (51mm) 0.00'' (0mm) 3.75'' (95mm) 5.25'' (133mm) N/A N/A PC-300 S/B 3.00'' (76mm) 0.00'' (0mm) 5.25'' (133mm) 6.75'' (171mm) N/A N/A PC-400 S/B 4.00'' (102mm) 0.00'' (0mm) 6.75'' (171mm) 8.25'' (210mm) N/A N/A PC-500 S/B 5.00'' (127mm) 0.00'' (0mm) 8.25'' (210mm) 9.75'' (248mm) N/A N/A PC-600 S/B 6.00'' (152mm) 0.00'' (0mm) 9.75'' (248mm) 11.25'' (286mm) N/A N/A PC-700 S/B 7.00'' (178mm) 0.00'' (0mm) 11.25'' (286mm) 12.75'' (324mm) N/A N/A PC-800 S/B 8.00'' (203mm) 0.00'' (0mm) 12.75'' (324mm) 14.25'' (362mm) N/A N/A PC-900 S/B 9.00'' (229mm) 0.00'' (0mm) 14.25'' (362mm) 15.75'' (400mm) N/A N/A PCW-100 S/B 1.00'' (25mm) 0.00'' (0mm) 2.25'' (57mm) 2.25'' (57mm) N/A N/A PCW-200 S/B 2.00'' (51mm) 0.00'' (0mm) 3.75'' (95mm) 3.75'' (95mm) N/A N/A PCW-300 S/B 3.00'' (76mm) 0.00'' (0mm) 5.25'' (133mm) 5.25'' (133mm) N/A N/A PCW-400 S/B 4.00'' (102mm) 0.00'' (0mm) 6.75'' (171mm) 6.75'' (171mm) N/A N/A PCW-500 S/B 5.00'' (127mm) 0.00'' (0mm) 8.25'' (210mm) 8.25'' (210mm) N/A N/A PCW-600 S/B 6.00'' (152mm) 0.00'' (0mm) 9.75'' (248mm) 9.75'' (248mm) N/A N/A PCW-700 S/B 7.00'' (178mm) 0.00'' (0mm) 11.25'' (286mm) 11.25'' (286mm) N/A N/A PCW-800 S/B 8.00'' (203mm) 0.00'' (0mm) 12.75'' (324mm) 12.75'' (324mm) N/A N/A PCW-900 S/B 9.00'' (229mm) 0.00'' (0mm) 14.25'' (362mm) 13.75'' (349mm) N/A N/A Contact factory for larger sizes. EXPOSED SURFACE 1/8" ST. STEEL OR BRONZE COVER PLATE JOINT PC-S/B (TYP.) 1/8" FORMED ST. STEEL OR BRONZE ANGLE COVER EXPOSED SURFACE JOINT PCW-S/B (TYP.) 1.82

85 SJP & SJPW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Standard Loading 500 lbs. Product Description: This Surface Mounted metal floor cover is designed for interior or exterior applications. The joint can be designed for up to 100% movement. Use This Cover For: Interior or exterior seismic applications. Applications requiring movements up to 100% of joint width. Larger sizes available (contact factory). Optional waterstop available for wet areas. Performance Characteristics: Self-centering aluminum center plate allows for thermal movement and seismic movement. Standard Finishes: Mill finish. Aluminum surfaces in contact with concrete will be protected with a minimum 2 mil coating of a heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Fasten cover plate to frames with turnbar. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

86 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SJP '' (25mm) 0.50'' (13mm) 4.00'' (102mm) 4.50'' (114mm) 2.50'' (64mm) 1.50'' (38mm) SJP '' (51mm) 1.00'' (25mm) 4.50'' (114mm) 4.50'' (114mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (76mm) 1.00'' (25mm) 4.75'' (121mm) 6.50'' (165mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (102mm) 1.00'' (25mm) 7.50'' (191mm) 7.50'' (191mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (127mm) 1.00'' (25mm) 7.50'' (191mm) 10.50'' (267mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (152mm) 1.00'' (25mm) 11.13'' (283mm) 11.88'' (302mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (178mm) 1.00'' (25mm) 12.25'' (311mm) 13.50'' (343mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (203mm) 1.00'' (25mm) 14.25'' (362mm) 15.00'' (381mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (229mm) 1.00'' (25mm) 16.50'' (419mm) 16.50'' (419mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (254mm) 1.00'' (25mm) 16.75'' (425mm) 17.94'' (456mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (279mm) 1.00'' (25mm) 16.75'' (425mm) 19.50'' (495mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (305mm) 1.00'' (25mm) 21.00'' (533mm) 21.00'' (533mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (330mm) 1.00'' (25mm) 21.00'' (533mm) 22.50'' (572mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (356mm) 1.00'' (25mm) 23.75'' (603mm) 23.88'' (606mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (381mm) 1.00'' (25mm) 24.25'' (616mm) 25.50'' (648mm) 2.25'' (57mm) 1.50'' (38mm) SJP '' (406mm) 1.00'' (25mm) 24.25'' (616mm) 27.00'' (686mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (25mm) 0.00'' (0mm) 2.50'' (64mm) 2.75'' (70mm) 2.50'' (64mm) 1.50'' (38mm) SJPW '' (51mm) 0.00'' (0mm) 3.25'' (83mm) 3.25'' (83mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (76mm) 0.00'' (0mm) 3.75'' (95mm) 4.75'' (121mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (102mm) 0.00'' (0mm) 5.75'' (146mm) 5.75'' (146mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (127mm) 0.00'' (0mm) 6.25'' (159mm) 7.75'' (197mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (152mm) 0.00'' (0mm) 8.50'' (216mm) 8.94'' (227mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (178mm) 4.00'' (102mm) 9.50'' (241mm) 10.25'' (260mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (203mm) 4.50'' (114mm) 10.00'' (254mm) 11.50'' (292mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (229mm) 5.00'' (127mm) 12.75'' (324mm) 12.75'' (324mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (254mm) 5.50'' (140mm) 13.31'' (338mm) 14.00'' (356mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (279mm) 6.00'' (152mm) 13.88'' (353mm) 15.25'' (387mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (305mm) 6.50'' (165mm) 16.50'' (419mm) 16.50'' (419mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (330mm) 7.00'' (178mm) 17.00'' (432mm) 17.75'' (451mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (356mm) 7.50'' (191mm) 18.75'' (476mm) 18.94'' (481mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (381mm) 8.00'' (203mm) 19.50'' (495mm) 20.25'' (514mm) 2.25'' (57mm) 1.50'' (38mm) SJPW '' (406mm) 8.50'' (216mm) 20.00'' (508mm) 21.50'' (546mm) 2.25'' (57mm) 1.50'' (38mm) Contact factory for larger sizes. EXPOSED SURFACE TURNBAR ASSEMBLY ALUMINUM COVER PLATE ALUMINUM FRAME EXPOSED SURFACE ALUMINUM COVER PLATE HEIGHT HEIGHT HEIGHT JOINT JOINT SJP (TYP.) SJPW (TYP.) 1.84

87 SJP-S / SJP-B & SJPW-S / SJPW-B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A- T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Bronze C28000 Muntz metal ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Standard Loading 500 lbs. Product Description: This surface mounted metal floor cover is designed for interior or exterior applications. The joint can be designed for up to 100% movement. Use This Cover For: Interior or exterior seismic applications. Applications requiring movements up to 100% of joint width. Larger sizes available (contact factory). Optional waterstop available for wet areas. Performance Characteristics: Self-centering aluminum center plate allows for thermal movement and seismic movement. Standard Finishes: Aluminum surfaces in contact with concrete will be protected with a minimum 2 mil coating of a heavy metal free high solids primer. Stainless steel No. 4 finish. Bronze Satin finish. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Fasten cover plate to frames with turnbar. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

88 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SJP-100 S/B 1.00'' (25mm) 0.50'' (13mm) 4.00'' (102mm) 4.50'' (114mm) 2.50'' (64mm) 1.50'' (38mm) SJP-200 S/B 2.00'' (51mm) 1.00'' (25mm) 4.50'' (114mm) 4.50'' (114mm) 2.25'' (57mm) 1.50'' (38mm) SJP-300 S/B 3.00'' (76mm) 1.00'' (25mm) 4.75'' (121mm) 6.50'' (165mm) 2.25'' (57mm) 1.50'' (38mm) SJP-400 S/B 4.00'' (102mm) 1.00'' (25mm) 7.50'' (191mm) 7.50'' (191mm) 2.25'' (57mm) 1.50'' (38mm) SJP-500 S/B 5.00'' (127mm) 1.00'' (25mm) 7.50'' (191mm) 10.50'' (267mm) 2.25'' (57mm) 1.50'' (38mm) SJP-600 S/B 6.00'' (152mm) 1.00'' (25mm) 11.13'' (283mm) 11.88'' (302mm) 2.25'' (57mm) 1.50'' (38mm) SJP-700 S/B 7.00'' (178mm) 1.00'' (25mm) 12.25'' (311mm) 13.50'' (343mm) 2.25'' (57mm) 1.50'' (38mm) SJP-800 S/B 8.00'' (203mm) 1.00'' (25mm) 14.25'' (362mm) 15.00'' (381mm) 2.25'' (57mm) 1.50'' (38mm) SJP-900 S/B 9.00'' (229mm) 1.00'' (25mm) 16.50'' (419mm) 16.50'' (419mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1000 S/B 10.00'' (254mm) 1.00'' (25mm) 16.75'' (425mm) 17.94'' (456mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1100 S/B 11.00'' (279mm) 1.00'' (25mm) 16.75'' (425mm) 19.50'' (495mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1200 S/B 12.00'' (305mm) 1.00'' (25mm) 21.00'' (533mm) 21.00'' (533mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1300 S/B 13.00'' (330mm) 1.00'' (25mm) 21.00'' (533mm) 22.50'' (572mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1400 S/B 14.00'' (356mm) 1.00'' (25mm) 23.75'' (603mm) 23.88'' (606mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1500 S/B 15.00'' (381mm) 1.00'' (25mm) 24.25'' (616mm) 25.50'' (648mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1600 S/B 16.00'' (406mm) 1.00'' (25mm) 24.25'' (616mm) 27.00'' (686mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-100 S/B 1.00'' (25mm) 0.00'' (0mm) 2.50'' (64mm) 2.75'' (70mm) 2.50'' (64mm) 1.50'' (38mm) SJPW-200 S/B 2.00'' (51mm) 0.00'' (0mm) 3.25'' (83mm) 3.25'' (83mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-300 S/B 3.00'' (76mm) 0.00'' (0mm) 3.75'' (95mm) 4.75'' (121mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-400 S/B 4.00'' (102mm) 0.00'' (0mm) 5.75'' (146mm) 5.75'' (146mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-500 S/B 5.00'' (127mm) 0.00'' (0mm) 6.25'' (159mm) 7.75'' (197mm)) 2.25'' (57mm) 1.50'' (38mm) SJPW-600 S/B 6.00'' (152mm) 0.00'' (0mm) 8.50'' (216mm) 8.94'' (227mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-700 S/B 7.00'' (178mm) 4.00'' (102mm) 9.50'' (241mm) 10.25'' (260mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-800 S/B 8.00'' (203mm) 4.50'' (114mm) 10.00'' (254mm) 11.50'' (292mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-900 S/B 9.00'' (229mm) 5.00'' (127mm) 12.75'' (324mm) 12.75'' (324mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-1000 S/B 10.00'' (254mm) 5.50'' (140mm) 13.38'' (340mm) 14.00'' (356mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-1100 S/B 11.00'' (279mm) 6.00'' (152mm) 13.88'' (353mm) 15.25'' (387mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-1200 S/B 12.00'' (305mm) 6.50'' (165mm) 16.50'' (419mm) 16.50'' (419mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-1300 S/B 13.00'' (330mm) 7.00'' (178mm) 17.00'' (432mm) 17.75'' (451mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-1400 S/B 14.00'' (356mm) 7.50'' (191mm) 18.75'' (476mm) 18.94'' (481mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-1500 S/B 15.00'' (381mm) 8.00'' (203mm) 19.50'' (495mm) 20.25'' (514mm) 2.25'' (57mm) 1.50'' (38mm) SJPW-1600 S/B 16.00'' (406mm) 8.50'' (216mm) 20.00'' (508mm) 21.50'' (546mm) 2.25'' (57mm) 1.50'' (38mm) Contact factory for larger sizes. TURNBAR ASSEMBLY EXPOSED SURFACE 3/16" ST. STEEL OR BRONZE CENTER PLATE 3/16" ST. STEEL OR BRONZE CENTER PLATE EXPOSED SURFACE ALUMINUM FRAME HEIGHT HEIGHT ALUMINUM FRAME HEIGHT JOINT JOINT SJP-S/B (TYP.) SJPW-S/B (TYP.) 1.86

89 SJP-M Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Standard Loading 500 lbs. Product Description: This surface mounted metal floor cover is designed for new to existing interior or exterior applications. The joint can be designed for up to 100% movement. Use This Cover For: Interior or exterior seismic applications. Applications requiring movements up to 100% of joint width. Larger sizes available (contact factory). Optional waterstop available for wet areas. New to Existing conditions. Performance Characteristics: Self-centering aluminum center plate allows for thermal movement and seismic movement. Standard Finishes: Mill finish. Aluminum surfaces in contact with concrete will be protected with a minimum 2 mil coating of a heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Fasten cover plate to frames with turnbar. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

90 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SJP-100M 1.00'' (25mm) 0.50'' (13mm) 4.25'' (108mm) 4.50'' (114mm) 3.25'' (83mm) 1.50'' (38mm) SJP-200M 2.00'' (51mm) 1.00'' (25mm) 4.75'' (121mm) 4.50'' (114mm) 2.75'' (70mm) 1.50'' (38mm) SJP-300M 3.00'' (76mm) 1.50'' (38mm) 5.38'' (137mm) 6.50'' (165mm) 2.25'' (57mm) 1.50'' (38mm) SJP-400M 4.00'' (102mm) 1.50'' (38mm) 8.50'' (216mm) 7.50'' (191mm) 2.25'' (57mm) 1.50'' (38mm) SJP-500M 5.00'' (127mm) 1.50'' (38mm) 8.50'' (216mm) 10.50'' (267mm) 2.25'' (57mm) 1.50'' (38mm) SJP-600M 6.00'' (152mm) 1.50'' (38mm) 12.00'' (305mm) 11.88'' (302mm) 2.25'' (57mm) 1.50'' (38mm) SJP-700M 7.00'' (178mm) 1.50'' (38mm) 13.38'' (340mm) 13.50'' (343mm) 2.25'' (57mm) 1.50'' (38mm) SJP-800M 8.00'' (203mm) 1.50'' (38mm) 13.38'' (340mm) 15.00'' (381mm) 2.25'' (57mm) 1.50'' (38mm) SJP-900M 9.00'' (229mm) 1.50'' (38mm) 17.38'' (441mm) 16.50'' (419mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1000M 10.00'' (254mm) 1.50'' (38mm) 17.63'' (448mm) 17.94'' (456mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1100M 11.00'' (279mm) 1.50'' (38mm) 17.63'' (448mm) 19.50'' (495mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1200M 12.00'' (305mm) 1.50'' (38mm) 21.88'' (556mm) 21.00'' (533mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1300M 13.00'' (330mm) 1.50'' (38mm) 22.00'' (559mm) 22.50'' (572mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1400M 14.00'' (356mm) 1.50'' (38mm) 24.38'' (619mm) 23.88'' (606mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1500M 15.00'' (381mm) 1.50'' (38mm) 25.13'' (638mm) 25.50'' (648mm) 2.25'' (57mm) 1.50'' (38mm) SJP-1600M 16.00'' (406mm) 1.50'' (38mm) 25.13'' (638mm) 27.00'' (686mm) 2.25'' (57mm) 1.50'' (38mm) Contact factory for larger sizes. ALUMINUM FRAME EXPOSED SURFACE ALUMINUM CENTER PLATE HEIGHT ALUMINUM NEW TO EXISTING FRAME JOINT NEW SLAB EXISTING SLAB SJP-M (TYP.) 1.88

91 SJPF & SJPFW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Standard Loading 500 lbs. Product Description: This flush mounted metal floor cover is designed for interior or exterior applications. The joint can be designed for up to 100% movement. Use This Cover For: Interior or exterior seismic applications. Applications requiring movements up to 100% of joint width. Larger sizes available (contact factory). Optional waterstop available for wet areas. Performance Characteristics: Self-centering aluminum center plate remains flush during thermal movement, but temporarily displaces and slides over floor surface during seismic movement. Standard Finishes: Mill finish. Aluminum surfaces in contact with concrete will be protected with a minimum 2 mil coating of a heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Fasten cover plate to frames with turnbar. Based on the size of the joint, there are recommended tips and tricks for installation at this point. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

92 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SJPF '' (25mm) 0.38'' (10mm) 3.00'' (76mm) 5.50'' (140mm) 3.50'' (89mm) 1.13'' (29mm) SJPF '' (51mm) 1.00'' (25mm) 4.00'' (102mm) 5.50'' (140mm) 3.00'' (76mm) 1.13'' (29mm) SJPF '' (76mm) 1.00'' (25mm) 4.63'' (117mm) 6.50'' (165mm) 3.00'' (76mm) 1.13'' (29mm) SJPF '' (102mm) 1.00'' (25mm) 6.50'' (165mm) 8.00'' (203mm) 3.00'' (76mm) 1.13'' (29mm) SJPF '' (127mm) 1.00'' (25mm) 7.50'' (191mm) 10.00'' (254mm) 3.00'' (76mm) 1.13'' (29mm) SJPF '' (152mm) 1.00'' (25mm) 9.88'' (251mm) 11.50'' (292mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW '' (25mm) 0.00'' (0mm) 2.00'' (51mm) 3.25'' (83mm) 3.38'' (86mm) 1.13'' (29mm) SJPFW '' (51mm) 0.00'' (0mm) 3.00'' (76mm) 3.75'' (95mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW '' (76mm) 0.00'' (0mm) 3.81'' (97mm) 4.75'' (121mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW '' (102mm) 0.00'' (0mm) 5.25'' (133mm) 6.00'' (152mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW '' (127mm) 0.00'' (0mm) 6.25'' (159mm) 7.50'' (191mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW '' (152mm) 0.00'' (0mm) 7.94'' (202mm) 8.75'' (222mm) 3.00'' (76mm) 1.13'' (29mm) Contact factory for larger sizes. EXPOSED SURFACE TURNBAR ASSEMBLY ALUMINUM COVER PLATE ALUMINUM FRAME HEIGHT HEIGHT JOINT SJPF (TYP.) EXPOSED SURFACE ALUMINUM FRAME ALUMINUM COVER PLATE HEIGHT JOINT SJPFW (TYP.) 1.90

93 SJPF-S / SJPF-B & SJPFW-S / SJPFW-B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Bronze C28000 Muntz metal ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Standard Loading 500 lbs. Product Description: This flush mounted metal floor cover is designed for interior or exterior applications. The joint can be designed for up to 100% movement. Use This Cover For: Interior or exterior seismic applications. Applications requiring movements up to 100% of joint width. Larger sizes available (contact factory). Optional waterstop available for wet areas. Performance Characteristics: Self-centering aluminum center plate remains flush during thermal movement, but temporarily displaces and slides over floor surface during seismic movement. Standard Finishes: Aluminum surfaces in contact with concrete will be protected with a minimum 2 mil coating of a heavy metal free high solids primer. Bronze Satin finish. Stainless steel No. 4 finish. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Fasten cover plate to frames with turnbar. Based on the size of the joint, there are recommended tips and tricks for installation at this point. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

94 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SJPF-100S/B 1.00'' (25mm) 0.38'' (10mm) 3.00'' (76mm) 5.50'' (140mm) 3.50'' (89mm) 1.13'' (29mm) SJPF-200S/B 2.00'' (51mm) 1.00'' (25mm) 4.00'' (102mm) 5.50'' (140mm) 3.00'' (76mm) 1.13'' (29mm) SJPF-300S/B 3.00'' (76mm) 1.00'' (25mm) 4.63'' (117mm) 6.50'' (165mm) 3.00'' (76mm) 1.13'' (29mm) SJPF-400S/B 4.00'' (102mm) 1.00'' (25mm) 6.50'' (165mm) 8.00'' (203mm) 3.00'' (76mm) 1.13'' (29mm) SJPF-500S/B 5.00'' (127mm) 1.00'' (25mm) 7.50'' (191mm) 10.00'' (254mm) 3.00'' (76mm) 1.13'' (29mm) SJPF-600S/B 6.00'' (152mm) 1.00'' (25mm) 9.88'' (251mm) 11.50'' (292mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW-100S/B 1.00'' (25mm) 0.00'' (0mm) 2.00'' (51mm) 3.25'' (83mm) 3.38'' (86mm) 1.13'' (29mm) SJPFW-200S/B 2.00'' (51mm) 0.00'' (0mm) 3.00'' (76mm) 3.75'' (95mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW-300S/B 3.00'' (76mm) 0.00'' (0mm) 3.81'' (97mm) 4.75'' (121mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW-400S/B 4.00'' (102mm) 0.00'' (0mm) 5.25'' (133mm) 6.00'' (152mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW-500S/B 5.00'' (127mm) 0.00'' (0mm) 6.25'' (159mm) 7.50'' (191mm) 3.00'' (76mm) 1.13'' (29mm) SJPFW-600S/B 6.00'' (152mm) 0.00'' (0mm) 7.94'' (202mm) 8.75'' (222mm) 3.00'' (76mm) 1.13'' (29mm) STAINLESS STEEL OR BRONZE CENTER PLATE EXPOSED SURFACE CONT. EXTRUDED ALUMINUM SIDE FRAME HEIGHT HEIGHT SPRING STEEL TURN BAR ASSEMBLY JOINT CONTINUOUS ALUMINUM ANCHOR FRAME NOTE: TURNBARS MUST BE PLACED IN FRAMES PRIOR TO FRAME ATTACHMENT SJPF-S/B (TYP.) EXPOSED SURFACE STAINLESS STEEL OR BRONZE CENTER PLATE CONTINUOUS EXTRUDED ALUMINUM SIDE FRAME HEIGHT CONTINUOUS ALUMINUM ANCHOR FRAME JOINT SJPFW-S/B (TYP.) 1.92

95 SJPF-M Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Standard Loading 500 lbs. Product Description: This flush mounted metal floor cover is designed for new to existing interior or exterior applications. The joint can be designed for up to 100% movement. Use This Cover For: Interior or exterior seismic applications. Applications requiring movements up to 100% of joint width. Larger sizes available (contact factory). Optional waterstop available for wet areas. New to Existing conditions. Performance Characteristics: Aluminum center plate remains flush during thermal movement, but temporarily displaces and slides over floor surface during seismic movement. Standard Finishes: Mill finish. Aluminum surfaces in contact with concrete will be protected with a minimum 2 mil coating of a heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frame in blockout and ledge frame to face of existing slab with C/S supplied fasteners. Attach cover plate to ledge frame. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

96 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SJPF-200M 2.00'' (51mm) 0.75'' (0mm) 3.00'' (76mm) 3.75'' (95mm) 3.00'' (76mm) 1.13'' (29mm) SJPF-300M 3.00'' (76mm) 0.75'' (0mm) 3.81'' (97mm) 4.75'' (121mm) 3.00'' (76mm) 1.13'' (29mm) SJPF-400M 4.00'' (102mm) 0.75'' (0mm) 5.25'' (133mm) 6.00'' (152mm) 3.00'' (76mm) 1.13'' (29mm) SJPF-500M 5.00'' (127mm) 0.75'' (0mm) 6.25'' (159mm) 7.50'' (191mm) 3.00'' (76mm) 1.13'' (29mm) SJPF-600M 6.00'' (152mm) 0.75'' (0mm) 7.94'' (202mm) 8.75'' (222mm) 3.00'' (76mm) 1.13'' (29mm) Contact factory for larger sizes. 3/16" ALUMINUM CENTER PLATE EXPOSED SURFACE ALUMINUM SIDE FRAME HEIGHT CONTINUOUS ALUMINUM ANCHOR FRAME CONTINUOUS EXTRUDED ALUMINUM NEW TO EXISTING LEDGE FRAME JOINT SJPF-M (TYP.) 1.94

97 SJ-HD & SJW-HD Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Standard Loading 2,000 lbs. Product Description: This flush mounted metal floor cover is designed for interior or exterior applications. The joint can be designed for up to 100% movement, and heavy-duty rolling loads are expected. Use This Cover For: Interior or exterior seismic applications. Applications requiring movements up to 100% of joint width. Larger sizes available (contact factory). Optional waterstop available for wet areas. Performance Characteristics: Self-centering aluminum center plate remains flush during thermal movement, but temporarily displaces and slides over floor surface during seismic movement. Standard Finishes: Mill finish. Aluminum surfaces in contact with concrete will be protected with a minimum 2 mil coating of a heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frames with C/S supplied fasteners. Fasten cover plate to frames with turnbar. Based on the size of the joint, there are recommended tips and tricks for installation at this point. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

98 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SJ-100HD 1.00'' (25mm) 0.38'' (10mm) 3.38'' (86mm) 8.75'' (222mm) 5.13'' (130mm) 1.38'' (35mm) SJ-200HD 2.00'' (51mm) 0.75'' (19mm) 4.38'' (111mm) 8.75'' (222mm) 4.63'' (117mm) 1.38'' (35mm) SJ-300HD 3.00'' (76mm) 1.75'' (44mm) 5.38'' (137mm) 8.75'' (222mm) 4.13'' (105mm) 1.38'' (35mm) SJ-400HD 4.00'' (102mm) 2.75'' (70mm) 6.38'' (162mm) 8.75'' (222mm) 3.63'' (92mm) 1.38'' (35mm) SJ-500HD 5.00'' (127mm) 2.75'' (70mm) 6.38'' (162mm) 9.75'' (248mm) 3.63'' (92mm) 1.38'' (35mm) SJ-600HD 6.00'' (152mm) 2.75'' (70mm) 9.25'' (235mm) 11.75'' (298mm) 4.13'' (105mm) 1.38'' (35mm) SJ-700HD 7.00'' (178mm) 2.75'' (70mm) 9.25'' (235mm) 13.75'' (349mm) 4.63'' (117mm) 1.38'' (35mm) SJ-800HD 8.00'' (203mm) 2.75'' (70mm) 14.13'' (359mm) 14.75'' (375mm) 4.63'' (117mm) 1.38'' (35mm) SJW-100HD 1.00'' (25mm) 0.00'' (0mm) 3.44'' (87mm) 5.63'' (143mm) 5.63'' (143mm) 1.38'' (35mm) SJW-200HD 2.00'' (51mm) 0.00'' (0mm) 4.44'' (113mm) 4.63'' (117mm) 4.63'' (117mm) 1.38'' (35mm) SJW-300HD 3.00'' (76mm) 0.00'' (0mm) 5.44'' (138mm) 4.13'' (105mm) 4.13'' (105mm) 1.38'' (35mm) SJW-400HD 4.00'' (102mm) 3.38'' (86mm) 5.19'' (132mm) 6.38'' (162mm) 4.63'' (117mm) 1.38'' (35mm) SJW-500HD 5.00'' (127mm) 3.88'' (98mm) 5.69'' (144mm) 7.38'' (187mm) 3.63'' (92mm) 1.38'' (35mm) SJW-600HD 6.00'' (152mm) 4.38'' (111mm) 7.63'' (194mm) 8.88'' (225mm) 3.63'' (92mm) 1.38'' (35mm) SJW-700HD 7.00'' (178mm) 4.88'' (124mm) 8.13'' (206mm) 10.38'' (264mm) 4.13'' (105mm) 1.38'' (35mm) SJW-800HD 8.00'' (203mm) 5.38'' (137mm) 11.06'' (281mm) 11.38'' (289mm) 4.63'' (117mm) 1.38'' (35mm) ALUMINUM COVER PLATE ALUMINUM FRAME TURNBAR ASSEMBLY EXPOSED SURFACE HEIGHT HEIGHT JOINT SJ-HD (TYP.) EXPOSED SURFACE ALUMINUM FRAME ALUMINUM COVER PLATE HEIGHT JOINT SJW-HD (TYP.) 1.96

99 SJ-HDM Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Standard Loading 2,000 lbs. Product Description: This flush mounted metal floor cover is designed for new to existing interior or exterior applications. The joint can be designed for up to 100% movement, and heavy-duty rolling loads are expected. Use This Cover For: Interior or exterior seismic applications. Applications requiring movements up to 100% of joint width. Larger sizes available (contact factory). Optional waterstop available for wet areas. New to Existing conditions. Performance Characteristics: Aluminum center plate remains flush during thermal movement, but temporarily displaces and slides over floor surface during seismic movement. Standard Finishes: Mill finish. Aluminum surfaces in contact with concrete will be protected with a minimum 2 mil coating of a heavy metal free high solids primer. Installation Guidelines: The blockouts must be prepared to receive the joint cover. It is recommended that the blockout be formed a minimum of 1/8 deeper to allow the base to be leveled prior to installation of the joint cover. Apply a high-strength leveling grout to the base of the blockouts to provide a continuous, solid, flat and level base for the joint cover. (Note: The blockouts must be level across the joint opening.) Install base frame in blockout and ledge frame to face of existing slab with C/S supplied fasteners. Attach cover plate to ledge frame. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

100 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SJ-200HDM 2.00'' (51mm) 1.00'' (25mm) 4.50'' (114mm) 5.38'' (137mm) 4.63'' (117mm) 1.38'' (35mm) SJ-300HDM 3.00'' (76mm) 1.50'' (38mm) 5.50'' (140mm) 6.38'' (162mm) 4.63'' (117mm) 1.38'' (35mm) SJ-400HDM 4.00'' (102mm) 2.00'' (51mm) 6.50'' (165mm) 7.38'' (187mm) 4.63'' (117mm) 1.38'' (35mm) SJ-500HDM 5.00'' (127mm) 2.00'' (51mm) 7.50'' (191mm) 8.38'' (213mm) 4.63'' (117mm) 1.38'' (35mm) SJ-600HDM 6.00'' (152mm) 4.13'' (105mm) 7.38'' (187mm) 9.38'' (238mm) 4.63'' (117mm) 1.38'' (35mm) SJ-700HDM 7.00'' (178mm) 4.75'' (121mm) 10.38'' (264mm) 10.38'' (264mm) 4.63'' (117mm) 1.38'' (35mm) SJ-800HDM 8.00'' (203mm) 5.13'' (130mm) 10.88'' (276mm) 11.38'' (289mm) 4.63'' (117mm) 1.38'' (35mm) EXPOSED SURFACE ALUMINUM FRAME ALUMINUM COVER PLATE HEIGHT JOINT ALUMINUM SUPPORT ANGLE SJ-HDM (TYP.) 1.98

101 Section 2 - Wall Covers Joint Size Page Nos. Joint Size Page Nos. 1" to 2" (2.3, 2.4 & 2.7, 2.8) 1" to 8" ( ) Gasketed Single Gasket 2" Only 3" to 5" 6" to 10" 2" to 4" 5" to 10" (2.5, 2.6) ( ) ( ) ( ) ( ) Metal Tamper Resistant Surface Plate w/ Turnbar 1" to 4" ( ) 4" to 16" ( ) Double gasket 2" to 4" 5" to 16" (2.25, 2.26) (2.27, 2.28) Remountable Panel 4" to 16" ( ) 2.1

102 Section 2 - Wall Covers In the wall covers section, you will find many different types and styles of wall covers that are designed for different joint sizes, degrees of movement and a variety of substrate materials. Some wall covers are designed to integrate with certain floor covers, while others are simply designed for the smallest exposed surface possible. With so many styles to choose from, you re certain to find a cover that gives you the results you are looking for. Gasketed Joint Covers Flush wall systems can accommodate expansion joint sizes of 1" to 10". Offer a minimal exposed surface and are available in single or dual-gasketed models. Vinyl gaskets are replaceable and are typically available in a variety of standard and custom colors to match adjacent finishes. Metal Joint Covers Metal cover systems can accommodate expansion joints that are 1" to 4" wide. Metal flush installation can be mounted directly to wall studs and are usually 5/8" deep to finish flush with surrounding drywall. Can also be used on drywall ceiling applications. ( See Section 3 - Ceiling Joint Covers ) Metal surface mounted installations are typically used for masonry applications where flush covers cannot be mounted into the wall surface. Seismic aluminum wall covers are available with aluminum, bronze, stainless steel, or Kynar painted center plates. 2.2

103 FWF & FWFC 100/200 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore-A, 90 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, wall and ceiling cover is ideal for applications where minimal visual impact is preferred. These models are also designed to match flush Thinline covers used in the floor. Use This Cover For: Wall applications to align with and match flush Thinline covers used in the floor. Suitable for G.W.B. wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The softer center section of the gasket flexes to allow full movement without the need for grooves in the surface which collect dirt. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers if not factory installed. Tape the edges of the aluminum retainer and feather drywall cement to provide a smooth transition to the drywall. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

104 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FWF '' (25mm) 0.60'' (15mm) 1.25'' (32mm) 1.06'' (27mm) N/A N/A FWF '' (51mm) 0.60'' (15mm) 2.50'' (64mm) 2.06'' (52mm) N/A N/A FWFC '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.06'' (27mm) N/A N/A FWFC '' (51mm) 0.75'' (19mm) 2.50'' (64mm) 2.06'' (52mm) N/A N/A JOINT JOINT WALL (N.I.C.) ALUMINUM FRAME EXPOSED SURFACE ALUMINUM FRAME FLEXIBLE GASKET FWF-100 FWF-200 WALL (N.I.C.) JOINT FLOOR TO WALL ALUMINUM FRAME JOINT ALUMINUM FRAME EXPOSED SURFACE ALUMINUM FRAME FLEXIBLE GASKET FWFC-100 FWFC

105 FWF-M & FWFC-M 200 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore-A, 90 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, wall and ceiling cover is ideal for applications where minimal visual impact is preferred. These models are also designed to match flush Thinline covers used in the floor. Use This Cover For: Wall applications to align with and match flush Thinline covers used in the floor. Suitable for most masonry and plaster wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The softer center section of the gasket flexes to allow full movement without the need for grooves in the surface which collect dirt. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

106 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FWF-200M 2.00'' (51mm) 1.00'' (25mm) 2.50'' (64mm) 2.00'' (51mm) N/A N/A FWFC-200M 2.00'' (51mm) 1.00'' (25mm) 2.50'' (64mm) 2.00'' (51mm) N/A N/A ALUMINUM FRAME JOINT WALL (N.I.C.) EXPOSED SURFACE FWF-200M FLEXIBLE GASKET ALUMINUM FRAME C/S SUPPLIED ADHESIVE JOINT WALL (N.I.C.) FLEXIBLE GASKET EXPOSED SURFACE FWFC-200M 2.6

107 GFS-W & GFSW-W Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105- T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM-D2000 Available in 4 colors. Product Description: GFS-W / GFSW-W is a gasketed wall joint cover comprised of extruded aluminum frames and a TPR seal. The extruded aluminum wall frame is designed to provide a minimal bump in a surface-mounted application. Use This Cover For: Applications with small, interior joints where minimal visual impact is preferred. Suitable for all wall finishes. Where hygiene is important. 1 and 2 joints. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the top surface which collect dirt. Standard Finishes: Mill finish. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: No blockouts required. System attaches to surface of substrate by using mechanical fasteners. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

108 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GFS-100W 1.00'' (25mm) 0.75'' (19mm) 1.25'' (32mm) 4.31'' (109mm) N/A N/A GFS-200W 2.00'' (51mm) 1.50'' (38mm) 2.50'' (64mm) 5.13'' (130mm) N/A N/A GFSW-100W 1.00'' (25mm) 0.75'' (19mm) 1.25'' (32mm) 2.66'' (68mm) N/A N/A GFSW-200W 2.00'' (51mm) 1.50'' (38mm) 2.50'' (64mm) 3.56'' (90mm) N/A N/A JOINT JOINT C.M.U. WALL ALUMINUM FRAME EXPOSED SURFACE FLEXIBLE GASKET EXPOSED SURFACE ALUMINUM FRAME SANTOPRENE GASKET GFS-100W GFS-200W JOINT JOINT ALUMINUM FRAME FLEXIBLE GASKET EXPOSED SURFACE ALUMINUM WALL FAME ALUMINUM FRAME SANTOPRENE GASKET EXPOSED SURFACE ALUMINUM WALL FRAME GFSW-100W GFSW-200W 2.8

109 FWF & FWFC 300/500 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, wall and ceiling cover is ideal for applications where minimal visual impact is preferred. These models are also designed to match flush Thinline covers used in the floor. Use This Cover For: Suitable for G.W.B. wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket flexes to allow full movement. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers if not factory installed. Tape the edges of the aluminum retainer and feather drywall compound to provide a smooth transition to the drywall. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

110 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FWF '' (76mm) 1.25'' (32mm) 4.50'' (114mm) 3.00'' (76mm) N/A N/A FWF '' (102mm) 1.25'' (32mm) 6.00'' (152mm) 4.00'' (102mm) N/A N/A FWF '' (127mm) 1.25'' (32mm) 7.50'' (191mm) 5.00'' (127mm) N/A N/A FWFC '' (76mm) 1.25'' (32mm) 4.50'' (114mm) 3.00'' (76mm) N/A N/A FWFC '' (102mm) 1.25'' (32mm) 6.00'' (152mm) 4.00'' (102mm) N/A N/A FWFC '' (127mm) 1.25'' (32mm) 7.50'' (191mm) 5.00'' (127mm) N/A N/A JOINT WALL (N.I.C.) ALUMINUM FRAME EXPOSED SURFACE FRAME CONCEALED BY FEATHERED JOINT COMPOUND (N.I.C.) FLEXIBLE GASKET FWF-300/500 WALL (N.I.C.) JOINT FRAME CONCEALED BY FEATHERED JOINT COMPOUND (N.I.C.) ALUMINUM FRAME EXPOSED SURFACE ALUMINUM FRAME FLEXIBLE GASKET FWFC-300/

111 FWF-M & FWFC-M 300/500 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, wall and ceiling cover is ideal for applications where minimal visual impact is preferred. These models are also designed to match flush Thinline covers used in the floor. Use This Cover For: Suitable for most masonry and plaster wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket flexes to allow full movement. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

112 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FWF-300M 3.00'' (76mm) 1.25'' (32mm) 4.50'' (114mm) 3.00'' (76mm) N/A N/A FWF-400M 4.00'' (102mm) 1.25'' (32mm) 6.00'' (152mm) 4.00'' (102mm) N/A N/A FWF-500M 5.00'' (127mm) 1.25'' (32mm) 7.50'' (191mm) 5.00'' (127mm) N/A N/A FWFC-300M 3.00'' (76mm) 1.25'' (32mm) 4.50'' (114mm) 3.00'' (76mm) N/A N/A FWFC-400M 4.00'' (102mm) 1.25'' (32mm) 6.00'' (152mm) 4.00'' (102mm) N/A N/A FWFC-500M 5.00'' (127mm) 1.25'' (32mm) 7.50'' (191mm) 5.00'' (127mm) N/A N/A JOINT ALUMINUM FRAME WALL (N.I.C.) EXPOSED SURFACE FLEXIBLE GASKET FWF-300/500M JOINT ALUMINUM FRAME FLEXIBLE GASKET EXPOSED SURFACE WALL (N.I.C.) FWFC-300/500M 2.12

113 FWF & FWFC 600/1000 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, wall and ceiling cover is ideal for applications where minimal visual impact is preferred. Use This Cover For: Suitable for G.W.B. wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket flexes to allow full movement. The gaskets are supported with an aluminum center mullion and turnbars (7 and larger). Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers if not factory installed. Tape the edges of the aluminum retainer and feather drywall cement to provide a smooth transition to the drywall. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

114 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FWF '' (152mm) 1.75'' (44mm) 9.00'' (229mm) 6.00'' (152mm) N/A N/A FWF '' (178mm) 2.50'' (64mm) 10.50'' (267mm) 7.00'' (178mm) N/A N/A FWF '' (203mm) 2.50'' (64mm) 12.00'' (305mm) 8.00'' (203mm) N/A N/A FWF '' (229mm) 2.50'' (64mm) 13.50'' (343mm) 9.00'' (229mm) N/A N/A FWF '' (254mm) 2.50'' (64mm) 15.00'' (381mm) 10.00'' (254mm) N/A N/A FWFC '' (152mm) 1.75'' (44mm) 9.00'' (229mm) 6.00'' (152mm) N/A N/A FWFC '' (178mm) 2.50'' (64mm) 10.50'' (267mm) 7.00'' (178mm) N/A N/A FWFC '' (203mm) 2.50'' (64mm) 12.00'' (305mm) 8.00'' (203mm) N/A N/A FWFC '' (229mm) 2.50'' (64mm) 14.00'' (356mm) 9.00'' (229mm) N/A N/A FWFC '' (254mm) 2.50'' (64mm) 15.00'' (381mm) 10.00'' (254mm) N/A N/A TURNBAR ASSEMBLY JOINT WALL (N.I.C.) ALUMINUM FRAME EXPOSED SURFACE FRAME CONCEALED BY FEATHERED JOINT COMPOUND (N.I.C.) ALUMINUM CENTER MULLION FLEXIBLE GASKET FWF-600/1000 TURNBAR ASSEMBLY JOINT WALL (N.I.C.) FRAME CONCEALED BY FEATHERED JOINT COMPOUND (N.I.C.) ALUMINUM FRAME ALUMINUM CENTER MULLION EXPOSED SURFACE ALUMINUM FRAME FLEXIBLE GASKET FWFC-600/1000 NOTE: No turnbar required for 6 models. 2.14

115 FWF-M & FWFC-M 600/1000 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105- T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, wall and ceiling cover is ideal for applications where minimal visual impact is preferred. Use This Cover For: Suitable for most masonry and plaster wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket flexes to allow full movement. The gaskets are supported with aluminum an aluminum center mullion and turnbars (7 and larger). Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

116 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FWF-600M 6.00'' (152mm) 1.75'' (44mm) 9.00'' (229mm) 6.00'' (152mm) N/A N/A FWF-700M 7.00'' (178mm) 2.50'' (64mm) 10.50'' (267mm) 7.00'' (178mm) N/A N/A FWF-800M 8.00'' (203mm) 2.50'' (64mm) 12.00'' (305mm) 8.00'' (203mm) N/A N/A FWF-900M 9.00'' (229mm) 2.50'' (64mm) 14.50'' (368mm) 9.00'' (229mm) N/A N/A FWF-1000M 10.00'' (254mm) 2.50'' (64mm) 15.00'' (381mm) 10.00'' (254mm) N/A N/A FWFC-600M 6.00'' (152mm) 1.75'' (44mm) 9.00'' (229mm) 6.00'' (152mm) N/A N/A FWFC-700M 7.00'' (178mm) 2.50'' (64mm) 10.50'' (267mm) 7.00'' (178mm) N/A N/A FWFC-800M 8.00'' (203mm) 2.50'' (64mm) 12.00'' (305mm) 8.00'' (203mm) N/A N/A FWFC-900M 9.00'' (229mm) 2.50'' (64mm) 14.50'' (368mm) 9.00'' (229mm) N/A N/A FWFC-1000M 10.00'' (254mm) 2.50'' (64mm) 15.00'' (381mm) 10.00'' (254mm) N/A N/A TURNBAR ASSEMBLY JOINT ALUMINUM FRAME WALL (N.I.C.) FLEXIBLE GASKET FWF-600/1000M TURNBAR ASSEMBLY JOINT ALUMINUM FRAME WALL (N.I.C.) FLEXIBLE GASKET FWFC-600/1000M NOTE: No turnbar required for 6 models. 2.16

117 FWS & FWSC 200/400 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, serrated wall and ceiling cover is ideal for applications where minimal visual impact is preferred. The covers used for FWS offer slightly more expansion than the FWF covers. Use This Cover For: Suitable for G.W.B. wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket is ribbed to allow for movement up to 100%. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers if not factory installed. Tape the edges of the aluminum retainer and feather drywall cement to provide a smooth transition to the drywall. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

118 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FWS '' (51mm) 1.25'' (32mm) 4.00'' (102mm) 2.00'' (51mm) N/A N/A FWS '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 3.00'' (76mm) N/A N/A FWS '' (102mm) 1.25'' (32mm) 8.00'' (203mm) 4.00'' (102mm) N/A N/A FWSC '' (51mm) 1.25'' (32mm) 4.00'' (102mm) 2.00'' (51mm) N/A N/A FWSC '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 3.00'' (76mm) N/A N/A FWSC '' (102mm) 1.25'' (32mm) 8.00'' (203mm) 4.00'' (102mm) N/A N/A JOINT JOINT ALUMINUM FRAME ALUMINUM FRAME FLEXIBLE PRIMARY SEAL FEATHERED JOINT CEMENT (BY OTHERS) FLEXIBLE PRIMARY SEAL FEATHERED JOINT CEMENT (BY OTHERS) FWS-200 FWS-300/400 ALUMINUM FRAME JOINT ALUMINUM FRAME JOINT ALUMINUM FRAME ALUMINUM FRAME FEATHERED JOINT CEMENT (BY OTHERS) FLEXIBLE PRIMARY SEAL FEATHERED JOINT CEMENT (BY OTHERS) FLEXIBLE PRIMARY SEAL FWSC-200 FWSC-300/

119 FWS-M & FWSC-M 200/400 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, serrated wall and ceiling cover is ideal for applications where minimal visual impact is preferred. The covers used for FWS offer slightly more expansion than the FWF covers. Use This Cover For: Suitable for masonry and plaster wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket is ribbed to allow for movement up to 100%. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

120 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FWS-200M 2.00'' (51mm) 1.25'' (32mm) 4.00'' (102mm) 2.00'' (51mm) N/A N/A FWS-300M 3.00'' (76mm) 1.25'' (32mm) 6.00'' (152mm) 3.00'' (76mm) N/A N/A FWS-400M 4.00'' (102mm) 1.25'' (32mm) 8.00'' (203mm) 4.00'' (102mm) N/A N/A FWSC-200M 2.00'' (51mm) 1.25'' (32mm) 4.00'' (102mm) 2.00'' (51mm) N/A N/A FWSC-300M 3.00'' (76mm) 1.25'' (32mm) 6.00'' (152mm) 3.00'' (76mm) N/A N/A FWSC-400M 4.00'' (102mm) 1.25'' (32mm) 8.00'' (203mm) 4.00'' (102mm) N/A N/A JOINT JOINT ALUMINUM FRAME FLEXIBLE PRIMARY SEAL ALUMINUM FRAME FLEXIBLE PRIMARY SEAL FWS-200M FWS-300/400M JOINT JOINT C/S SUPPLIED ADHESIVE ALUMINUM FRAME WALL (N.I.C.) SANTOPRENE FLEXIBLE SEAL ALUMINUM FRAME FLEXIBLE PRIMARY SEAL FWSC-200M FWSC-300/400M 2.20

121 FWS & FWSC 500/1000 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, serrated wall and ceiling cover is ideal for applications where minimal visual impact is preferred. The gaskets used for FWS offer more expansion than the FWF covers. Use This Cover For: Suitable for G.W.B. wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket is ribbed to allow for movement up to 100%. The gaskets are supported with an aluminum center mullion and turnbars (7 and larger). Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers if not factory installed. Tape the edges of the aluminum retainer and feather drywall cement to provide a smooth transition to the drywall. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

122 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE FWS '' (127mm) 1.75'' (44mm) 10.00'' (254mm) 5.00'' (127mm) N/A FWS '' (152mm) 1.75'' (44mm) 12.00'' (305mm) 6.00'' (152mm) N/A FWS '' (178mm) 2.50'' (64mm) 14.00'' (356mm) 7.00'' (178mm) N/A FWS '' (203mm) 2.50'' (64mm) 16.00'' (406mm) 8.00'' (203mm) N/A FWS '' (229mm) 2.50'' (64mm) 18.00'' (457mm) 9.00'' (229mm) N/A FWS '' (254mm) 2.50'' (64mm) 20.00'' (508mm) 10.00'' (254mm) N/A FWSC '' (127mm) 1.75'' (44mm) 10.00'' (254mm) 5.00'' (127mm) N/A FWSC '' (152mm) 1.75'' (44mm) 12.00'' (305mm) 6.00'' (152mm) N/A FWSC '' (178mm) 2.50'' (64mm) 14.00'' (356mm) 7.00'' (178mm) N/A FWSC '' (203mm) 2.50'' (64mm) 16.00'' (406mm) 8.00'' (203mm) N/A FWSC '' (229mm) 2.50'' (64mm) 18.00'' (457mm) 9.00'' (229mm) N/A FWSC '' (254mm) 2.50'' (64mm) 20.00'' (508mm) 10.00'' (254mm) N/A TURNBAR ASSEMBLY JOINT ALUMINUM FRAME FLEXIBLE PRIMARY SEAL ALUMINUM CENTER MULLION FEATHERED JOINT CEMENT (BY OTHERS) FWS-500/1000 TURNBAR ASSEMBLY ALUMINUM FRAME JOINT ALUMINUM FRAME FEATHERED JOINT CEMENT (BY OTHERS) ALUMINUM CENTER MULLION FLEXIBLE PRIMARY SEAL FWSC-500/1000 NOTE: No turnbar required for 5 and 6 models. 2.22

123 FWS-M & FWSC-M 500/1000 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore-A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, serrated wall and ceiling cover is ideal for applications where minimal visual impact is preferred. The covers used for FWS offer slightly more expansion than the FWF covers. Use This Cover For: Suitable for masonry and plaster wall and ceiling construction retainer configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket is ribbed to allow for movement up to 100%. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the aluminum retainers to the wall using mechanical fasteners. Install gasket into the retainers. Apply the appropriate wall finish as required. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

124 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FWS-500M 5.00'' (127mm) 1.75'' (44mm) 10.00'' (254mm) 5.00'' (127mm) N/A N/A FWS-600M 6.00'' (152mm) 1.75'' (44mm) 12.00'' (305mm) 6.00'' (152mm) N/A N/A FWS-700M 7.00'' (178mm) 2.50'' (64mm) 14.00'' (356mm) 7.00'' (178mm) N/A N/A FWS-800M 8.00'' (203mm) 2.50'' (64mm) 16.00'' (406mm) 8.00'' (203mm) N/A N/A FWS-900M 9.00'' (229mm) 2.50'' (64mm) 18.00'' (457mm) 9.00'' (229mm) N/A N/A FWS-1000M 10.00'' (254mm) 2.50'' (64mm) 20.00'' (508mm) 10.00'' (254mm) N/A N/A FWSC-500M 5.00'' (127mm) 1.75'' (44mm) 10.00'' (254mm) 5.00'' (127mm) N/A N/A FWSC-600M 6.00'' (152mm) 1.75'' (44mm) 12.00'' (305mm) 6.00'' (152mm) N/A N/A FWSC-700M 7.00'' (178mm) 2.50'' (64mm) 14.00'' (356mm) 7.00'' (178mm) N/A N/A FWSC-800M 8.00'' (203mm) 2.50'' (64mm) 16.00'' (406mm) 8.00'' (203mm) N/A N/A FWSC-900M 9.00'' (229mm) 2.50'' (64mm) 18.00'' (457mm) 9.00'' (229mm) N/A N/A FWSC-1000M 10.00'' (254mm) 2.50'' (64mm) 20.00'' (508mm) 10.00'' (254mm) N/A N/A TURNBAR ASSEMBLY JOINT ALUMINUM FRAME FLEXIBLE PRIMARY SEAL ALUMINUM CENTER MULLION FEATHERED JOINT CEMENT (BY OTHERS) FWS-500/1000M TURNBAR ASSEMBLY ALUMINUM FRAME JOINT ALUMINUM FRAME FEATHERED JOINT CEMENT (BY OTHERS) ALUMINUM CENTER MULLION FLEXIBLE PRIMARY SEAL FWSC-500/1000M NOTE: No turnbar required for 5 and 6 models. 2.24

125 GTW & GTWC Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Injection Molded, Glass-Reinforced Plastic Product Description: This dual gasket, flush wall cover is ideal for areas with larger thermal movement requirements. This model is also designed to match flush Twinline covers used in the floor. Use This Cover For: Wall and ceiling applications to match flush Twinline covers used in the floor. Suitable for most wall and ceiling finishes. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the face surface which collect dirt. Dual gaskets allow for greater expansion and compression during movement. Durable self-centering aluminum plate spans joint opening. Standard Finishes: Clear anodize on any exposed aluminum. Aluminum center plate can be painted to match adjacent wall finishes. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: The blockouts must be prepared to receive the expansion joint cover. Attach the aluminum retainers to wall using mechanical fasteners. This model also uses a turnbar assembly. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

126 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT GTW '' (51mm) 1.25'' (32mm) 3.75'' (95mm) 6.50'' (165mm) 2.25'' (57mm) 0.63'' (16mm GTW '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 10.00'' (254mm) 3.50'' (89mm) 0.63'' (16mm GTW '' (102mm) 1.25'' (32mm) 6.25'' (159mm) 11.00'' (279mm) 3.50'' (89mm) 0.63'' (16mm GTWC '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 4.25'' (108mm) 2.25'' (57mm) 0.63'' (16mm GTWC '' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.63'' (16mm GTWC '' (102mm) 2.50'' (64mm) 5.50'' (140mm) 7.50'' (191mm) 3.50'' (89mm) 0.63'' (16mm JOINT HEIGHT TURNBAR ASSEMBLY ALUMINUM FRAME HEIGHT EXPOSED SURFACE GTW (TYP.) JOINT HEIGHT ALUMINUM COVER PLATE EXPOSED SURFACE GTWC (TYP.) 2.26

127 SGW & SGWC Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Product Description: This dual gasket, flush wall cover is ideal for areas with larger movement requirements. This model is also designed to match flush Twinline covers used in the floor. Use This Cover For: Wall and ceiling applications to match flush Twinline covers used in the floor. Suitable for G.W.B. wall and ceiling finishes. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket allows full movement without the need for grooves in the face surface which collect dirt. Dual gaskets allow for greater expansion and compression during movement. Durable self-centering aluminum plate spans joint opening. Standard Finishes: Clear anodize on any exposed aluminum. Cover plate can be painted to match adjacent wall finishes. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Blockouts must be prepared to receive the joint cover. Attach aluminum retainers to wall using mechanical fasteners. There are some great tips in the complete C/S installation instructions. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

128 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SGW '' (127mm) 2.75'' (70mm) 8.75'' (222mm) 12.00'' (305mm) 3.50'' (89mm) 0.63'' (16mm) SGW '' (152mm) 2.75'' (70mm) 9.25'' (235mm) 13.00'' (330mm) 3.50'' (89mm) 0.63'' (16mm) SGW '' (178mm) 2.75'' (70mm) 11.75'' (298mm) 15.00'' (381mm) 4.00'' (102mm) 0.63'' (16mm) SGW '' (203mm) 2.75'' (70mm) 12.75'' (324mm) 16.00'' (406mm) 4.00'' (102mm) 0.63'' (16mm) SGW '' (229mm) 2.75'' (70mm) 14.13'' (359mm) 18.00'' (457mm) 4.50'' (114mm) 0.63'' (16mm) SGW '' (254mm) 2.75'' (70mm) 15.75'' (400mm) 19.00'' (483mm) 4.50'' (114mm) 0.63'' (16mm) SGW '' (279mm) 2.75'' (70mm) 17.75'' (451mm) 21.00'' (533mm) 5.00'' (127mm) 0.63'' (16mm) SGW '' (305mm) 2.75'' (70mm) 18.75'' (476mm) 22.00'' (559mm) 5.00'' (127mm) 0.63'' (16mm) SGW '' (330mm) 2.75'' (70mm) 20.75'' (527mm) 24.00'' (610mm) 5.50'' (140mm) 0.63'' (16mm) SGW '' (356mm) 2.75'' (70mm) 21.75'' (552mm) 25.00'' (635mm) 5.50'' (140mm) 0.63'' (16mm) SGW '' (381mm) 2.75'' (70mm) 22.75'' (578mm) 27.00'' (686mm) 6.00'' (152mm) 0.63'' (16mm) SGW '' (406mm) 2.75'' (70mm) 24.75'' (629mm) 28.00'' (711mm) 6.00'' (152mm) 0.63'' (16mm) SGWC '' (127mm) 3.75'' (95mm) 6.75'' (171mm) 8.50'' (216mm) 3.50'' (89mm) 0.63'' (16mm) SGWC '' (152mm) 4.25'' (108mm) 7.50'' (191mm) 9.50'' (241mm) 3.50'' (89mm) 0.63'' (16mm) SGWC '' (178mm) 5.00'' (127mm) 9.25'' (235mm) 11.00'' (279mm) 4.00'' (102mm) 0.63'' (16mm) SGWC '' (203mm) 5.50'' (140mm) 10.25'' (260mm) 12.00'' (305mm) 4.00'' (102mm) 0.63'' (16mm) SGWC '' (229mm) 6.00'' (152mm) 11.50'' (292mm) 13.50'' (343mm) 4.50'' (114mm) 0.63'' (16mm) SGWC '' (254mm) 6.50'' (165mm) 12.75'' (324mm) 14.50'' (368mm) 4.50'' (114mm) 0.63'' (16mm) SGWC '' (279mm) 7.00'' (178mm) 14.25'' (362mm) 16.00'' (406mm) 5.00'' (127mm) 0.63'' (16mm) SGWC '' (305mm) 7.50'' (191mm) 15.25'' (387mm) 17.00'' (432mm) 5.00'' (127mm) 0.63'' (16mm) SGWC '' (330mm) 8.00'' (203mm) 16.75'' (425mm) 18.50'' (470mm) 5.50'' (140mm) 0.63'' (16mm) SGWC '' (356mm) 8.50'' (216mm) 17.75'' (451mm) 19.50'' (495mm) 5.50'' (140mm) 0.63'' (16mm) SGWC '' (381mm) 9.00'' (229mm) 18.75'' (476mm) 21.00'' (533mm) 6.00'' (152mm) 0.63'' (16mm) SGWC '' (406mm) 9.50'' (241mm) 20.25'' (514mm) 22.00'' (559mm) 6.00'' (152mm) 0.63'' (16mm) Call factory for joints larger than 16 JOINT HEIGHT TURNBAR ASSEMBLY ALUMINUM FRAME HEIGHT EXPOSED SURFACE SGW (TYP.) JOINT HEIGHT ALUMINUM CORNER FRAME ASSEMBLY EXPOSED SURFACE SGWC (TYP.) 2.28

129 AFW & AFWC 100/800 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Duroflex Gasket Single Durometer 65 Shore A, ASTM D2000 Color - Gray Product Description: This metal wall and ceiling cover is designed for interior applications where low maintenance or tamper-resistance applications are desirable. Use This Cover For: Interior applications to match Allway metal floor covers. A flush finish in drywall applications. Performance Characteristics: Free-floating aluminum center plate spans joint and slides between retainer assemblies to allow movement when required. Cover can be painted to match wall finish. Standard Finishes: Clear anodize finish. Kynar paint available. Installation Guidelines: Install the retainer with the anchor bolts as supplied by C/S. The center plate is retained by the cover plates, which engage interlocking channels. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

130 MODEL JOINT MINIMUM MAXIMUM EXPOSED EXPOSED OPENING OPENING SURFACE A SURFACE B HEIGHT AFW '' (25mm) 0.25'' (6mm) 1.88'' (48mm) 5.00'' (127mm) N/A 2.00'' (51mm) 0.63'' (16mm) AFW '' (51mm) 0.38'' (10mm) 3.50'' (89mm) 7.75'' (197mm) N/A 2.88'' (73mm) 0.63'' (16mm) AFW '' (76mm) 0.00'' (0mm) 6.38'' (162mm) 10.75'' (273mm) N/A 3.88'' (98mm) 0.63'' (16mm) AFW '' (102mm) 1.00'' (25mm) 7.38'' (187mm) 11.75'' (298mm) N/A 3.88'' (98mm) 0.63'' (16mm) AFW '' (127mm) 2.25'' (57mm) 8.00'' (203mm) 12.75'' (324mm) N/A 3.88'' (98mm) 0.63'' (16mm) AFW '' (152mm) 3.25'' (83mm) 9.00'' (229mm) 13.75'' (349mm) N/A 3.88'' (98mm) 0.63'' (16mm) AFW '' (178mm) 3.25'' (83mm) 11.00'' (279mm) 17.00'' (432mm) N/A 5.00'' (127mm) 0.63'' (16mm) AFW '' (203mm) 4.00'' (102mm) 12.00'' (305mm) 18.00'' (457mm) N/A 5.00'' (127mm) 0.63'' (16mm) AFWC '' (25mm) 0.63'' (16mm) 1.44'' (37mm) 2.38'' (60mm) 2.00'' (51mm) 2.00'' (51mm) 0.63'' (16mm) AFWC '' (51mm) 1.19'' (30mm) 2.75'' (70mm) 4.25'' (108mm) 3.00'' (76mm) 2.88'' (73mm) 0.63'' (16mm) AFWC '' (76mm) 1.50'' (38mm) 4.69'' (119mm) 6.25'' (159mm) 5.25'' (133mm) 3.88'' (98mm) 0.63'' (16mm) AFWC '' (102mm) 2.50'' (64mm) 5.69'' (144mm) 7.25'' (184mm) 5.25'' (133mm) 3.88'' (98mm) 0.63'' (16mm) AFWC '' (127mm) 3.63'' (92mm) 6.50'' (165mm) 8.25'' (210mm) 5.25'' (133mm) 3.88'' (98mm) 0.63'' (16mm) AFWC '' (152mm) 4.63'' (117mm) 7.50'' (191mm) 9.25'' (235mm) 5.25'' (133mm) 3.88'' (98mm) 0.63'' (16mm) AFWC '' (178mm) 5.00'' (127mm) 9.00'' (229mm) 11.38'' (289mm) 5.25'' (133mm) 5.00'' (127mm) 0.63'' (16mm) AFWC '' (203mm) 6.00'' (152mm) 10.00'' (254mm) 12.38'' (314mm) 5.25'' (133mm) 5.00'' (127mm) 0.63'' (16mm) JOINT HEIGHT HEIGHT ALUMINUM CLIP EXPOSED SURFACE 'A' AFW (TYP.) HEIGHT JOINT ALUMINUM CLIP EXPOSED SURFACE 'B' ANGLED ALUMINUM CENTER PLATE EXPOSED SURFACE 'A' HEIGHT AFWC (TYP.) 2.30

131 AFW-S/AFWC-S & AFW-B/AFWC-B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T6) Duroflex Gasket Single Durometer 65 Shore A, ASTM D2000 Color Gray Bronze C28000 Muntz Metal, ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Product Description: This metal wall and ceiling cover is designed for interior applications where low maintenance or tamper-resistant applications are desirable. Use This Cover For: Interior applications to match Allway metal floor covers. A flush finish in drywall applications. Performance Characteristics: Free-floating bronze or stainless steel center plate spans joint and slides between retainer assemblies to allow movement when required. Standard Finishes: Bronze - Satin Finish. Stainless Steel No. 4 Finish Installation Guidelines: Install the retainer with the anchor bolts as supplied by C/S. The center plate is retained by the cover plates, which engage interlocking channels. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

132 MODEL JOINT MINIMUM MAXIMUM EXPOSED EXPOSED OPENING OPENING SURFACE A SURFACE B HEIGHT AFW-100S/B 1.00'' (25mm) 0.25'' (6mm) 1.88'' (48mm) 5.00'' (127mm) N/A 2.00'' (51mm) 0.63'' (16mm) AFW-200S/B 2.00'' (51mm) 0.38'' (10mm) 3.50'' (89mm) 7.75'' (197mm) N/A 2.88'' (73mm) 0.63'' (16mm) AFW-300S/B 3.00'' (76mm) 0.00'' (0mm) 6.38'' (162mm) 10.75'' (273mm) N/A 3.88'' (98mm) 0.63'' (16mm) AFW-400S/B 4.00'' (102mm) 1.00'' (25mm) 7.38'' (187mm) 11.75'' (298mm) N/A 3.88'' (98mm) 0.63'' (16mm) AFW-500S/B 5.00'' (127mm) 2.25'' (57mm) 8.00'' (203mm) 12.75'' (324mm) N/A 3.88'' (98mm) 0.63'' (16mm) AFW-600S/B 6.00'' (152mm) 3.25'' (83mm) 9.00'' (229mm) 13.75'' (349mm) N/A 3.88'' (98mm) 0.63'' (16mm) AFW-700S/B 7.00'' (178mm) 3.25'' (83mm) 11.00'' (279mm) 17.00'' (432mm) N/A 5.00'' (127mm) 0.63'' (16mm) AFW-800S/B 8.00'' (203mm) 4.00'' (102mm) 12.00'' (305mm) 18.00'' (457mm) N/A 5.00'' (127mm) 0.63'' (16mm) AFWC-100S/B 1.00'' (25mm) 0.63'' (16mm) 1.44'' (37mm) 2.38'' (60mm) 2.00'' (51mm) 2.00'' (51mm) 0.63'' (16mm) AFWC-200S/B 2.00'' (51mm) 1.19'' (30mm) 2.75'' (70mm) 4.25'' (108mm) 3.00'' (76mm) 2.88'' (73mm) 0.63'' (16mm) AFWC-300S/B 3.00'' (76mm) 1.50'' (38mm) 4.69'' (119mm) 6.25'' (159mm) 5.25'' (133mm) 3.88'' (98mm) 0.63'' (16mm) AFWC-400S/B 4.00'' (102mm) 2.50'' (64mm) 5.69'' (144mm) 7.25'' (184mm) 5.25'' (133mm) 3.88'' (98mm) 0.63'' (16mm) AFWC-500S/B 5.00'' (127mm) 3.63'' (92mm) 6.50'' (165mm) 8.25'' (210mm) 5.25'' (133mm) 3.88'' (98mm) 0.63'' (16mm) AFWC-600S/B 6.00'' (152mm) 4.63'' (117mm) 7.50'' (191mm) 9.25'' (235mm) 5.25'' (133mm) 3.88'' (98mm) 0.63'' (16mm) AFWC-700S/B 7.00'' (178mm) 5.00'' (127mm) 9.00'' (229mm) 11.38'' (289mm) 5.25'' (133mm) 5.00'' (127mm) 0.63'' (16mm) AFWC-800S/B 8.00'' (203mm) 6.00'' (152mm) 10.00'' (254mm) 12.38'' (314mm) 5.25'' (133mm) 5.00'' (127mm) 0.63'' (16mm) JOINT HEIGHT HEIGHT ALUMINUM FRAME WITH BRONZE OR STAINLESS STEEL LAMINATE BRONZE OR STAINLESS STEEL CENTER PLATE EXPOSED SURFACE AFW-S/B (TYP.) JOINT HEIGHT EXPOSED SURFACE 'B' BRONZE OR STAINLESS STEEL CENTER PLATE ALUMINUM FRAME WITH BRONZE OR STAINLESS STEEL LAMINATE EXPOSED SURFACE 'A' HEIGHT AFWC-S/B (TYP.) 2.32

133 ASM & ASMC Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T6) Duroflex Gasket Single Durometer 80 Shore A, ASTM D2000 Color - Gray Product Description: This surface mounted metal wall and ceiling cover is designed for applications where low maintenance or tamper proof applications are desirable. Use This Cover For: Applications where low maintenance is desirable or for tamperresistant applications. Performance Characteristics: Free-floating aluminum center plate spans joint and slides over the surface of the wall to allow movement when required. Cover can be painted to match wall finish. Standard Finishes: Clear anodize finish. Kynar painted top plates available. Installation Guidelines: Install anchor clips with the anchor bolts as supplied by C/S. The cover plate engages a J-Hook and locking channel for attachment. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

134 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ASM '' (25mm) 0.38'' (10mm) 3.00'' (76mm) 4.63'' (117mm) N/A N/A ASM '' (51mm) 0.38'' (10mm) 3.00'' (76mm) 4.63'' (117mm) N/A N/A ASM '' (76mm) 0.38'' (10mm) 6.00'' (152mm) 7.63'' (194mm) N/A N/A ASM '' (102mm) 0.38'' (10mm) 6.00'' (152mm) 7.63'' (194mm) N/A N/A ASMC '' (25mm) 0.50'' (13mm) 3.00'' (76mm) 3.38'' (86mm) N/A N/A ASMC '' (51mm) 0.50'' (13mm) 3.00'' (76mm) 3.38'' (86mm) N/A N/A ASMC '' (76mm) 0.50'' (13mm) 6.00'' (152mm) 6.38'' (162mm) N/A N/A ASMC '' (102mm) 0.50'' (13mm) 6.00'' (152mm) 6.38'' (162mm) N/A N/A 2" WIDE BACK CLIP DUROFLEX GASKET JOINT ALUMINUM COVER PLATE EXPOSED SURFACE ASM (TYP.) 2" WIDE BACK CLIP DUROFLEX GASKET JOINT 1 3/4" EXPOSED SURFACE ALUMINUM COVER PLATE ASMC (TYP.) 2.34

135 ASM-S/B & ASMC-S/B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T6) Duroflex Gasket Single Durometer 80 Shore A, ASTM D2000 Color - Gray Bronze C28000 Muntz Metal, ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Product Description: This surface mounted metal wall and ceiling cover is designed for applications where low maintenance or tamper-resistant applications are desirable. Use This Cover For: Applications where low maintenance is desirable or for tamperresistant applications. Applications where a bronze or stainless steel finish is desired. Performance Characteristics: Free-floating aluminum center plate spans joint and slides over the surface of the wall to allow movement when required. Cover can be painted to match wall finish. Standard Finishes: Bronze Satin Finish. Stainless Steel No. 4 Finish. Installation Guidelines: Install anchor clips with the anchor bolts as supplied by C/S. The cover plate engages a J-Hook and locking channel for attachment. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

136 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ASM-100S/B 1.00'' (25mm) 0.38'' (10mm) 1.50'' (38mm) 3.13'' (79mm) N/A N/A ASM-200S/B 2.00'' (51mm) 0.38'' (10mm) 3.00'' (76mm) 4.63'' (117mm) N/A N/A ASM-300S/B 3.00'' (76mm) 0.38'' (10mm) 6.00'' (152mm) 7.63'' (194mm) N/A N/A ASM-400S/B 4.00'' (102mm) 0.38'' (10mm) 6.00'' (152mm) 7.63'' (194mm) N/A N/A ASMC-100S/B 1.00'' (25mm) 0.50'' (13mm) 1.50'' (38mm) 1.88'' (48mm) N/A N/A ASMC-200S/B 2.00'' (51mm) 0.50'' (13mm) 3.00'' (76mm) 3.38'' (86mm) N/A N/A ASMC-300S/B 3.00'' (76mm) 0.50'' (13mm) 6.00'' (152mm) 6.38'' (162mm) N/A N/A ASMC-400S/B 4.00'' (102mm) 0.50'' (13mm) 6.00'' (152mm) 6.38'' (162mm) N/A N/A 2" WIDE BACK CLIP DUROFLEX GASKET JOINT ALUMINUM COVER PLATE EXPOSED SURFACE BRONZE OR STAINLESS STEEL LAMINATE ASM-S/B (TYP.) DUROFLEX GASKET JOINT 2" WIDE BACK CLIP 1 3/4" ALUMINUM COVER PLATE EXPOSED SURFACE BRONZE OR STAINLESS STEEL LAMINATE ASMC-S/B (TYP.) 2.36

137 SFW & SCW 400/1600 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T6) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Duroflex Gasket Single Durometer 80 Shore A, ASTM D200 Color - Gray Turnbar Material - C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Product Description: This surface mounted metal wall cover is designed for interior applications where low maintenance is desirable. Use This Cover For: Interior applications to match Allway metal floor covers. Interior applications where low maintenance is desirable. Performance Characteristics: Self-centering aluminum center plate spans joint and slides between retainer assemblies to allow movement when required. Cover can be painted to match wall finish. Standard Finishes: Clear anodize finish. Kynar paint available. Installation Guidelines: Install the retainer with the fasteners as supplied by C/S. This model also uses a turnbar assembly. There are some great tips in the complete C/S installation instructions. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

138 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SFW '' (102mm) 2.75'' (70mm) 7.25'' (184mm) 7.50'' (191mm) N/A N/A SFW '' (127mm) 2.75'' (70mm) 9.50'' (241mm) 10.50'' (267mm) N/A N/A SFW '' (152mm) 2.75'' (70mm) 9.50'' (241mm) 11.94'' (303mm) N/A N/A SFW '' (178mm) 2.75'' (70mm) 13.25'' (337mm) 13.50'' (343mm) N/A N/A SFW '' (203mm) 2.75'' (70mm) 14.75'' (375mm) 15.00'' (381mm) N/A N/A SFW '' (229mm) 2.75'' (70mm) 14.25'' (362mm) 16.50'' (419mm) N/A N/A SFW '' (254mm) 2.75'' (70mm) 17.50'' (445mm) 17.94'' (456mm) N/A N/A SFW '' (279mm) 2.75'' (70mm) 18.50'' (470mm) 19.50'' (495mm) N/A N/A SFW '' (305mm) 2.75'' (70mm) 18.50'' (470mm) 21.00'' (533mm) N/A N/A SFW '' (330mm) 2.75'' (70mm) 22.25'' (565mm) 22.50'' (572mm) N/A N/A SFW '' (356mm) 2.75'' (70mm) 23.00'' (584mm) 23.94'' (608mm) N/A N/A SFW '' (381mm) 2.75'' (70mm) 23.00'' (584mm) 25.50'' (648mm) N/A N/A SFW '' (406mm) 2.75'' (70mm) 26.00'' (660mm) 27.00'' (686mm) N/A N/A SCW '' (102mm) 0.00'' (0mm) 5.50'' (140mm) 5.75'' (146mm) N/A N/A SCW '' (127mm) 0.00'' (0mm) 7.50'' (191mm) 7.50'' (191mm) N/A N/A SCW '' (152mm) 0.00'' (0mm) 8.75'' (222mm) 9.00'' (229mm) N/A N/A SCW '' (178mm) 5.00'' (127mm) 10.00'' (254mm) 10.25'' (260mm) N/A N/A SCW '' (203mm) 5.50'' (140mm) 11.25'' (286mm) 11.50'' (292mm) N/A N/A SCW '' (229mm) 6.00'' (152mm) 11.50'' (292mm) 12.75'' (324mm) N/A N/A SCW '' (254mm) 6.50'' (165mm) 13.75'' (349mm) 14.00'' (356mm) N/A N/A SCW '' (279mm) 7.00'' (178mm) 14.75'' (375mm) 15.25'' (387mm) N/A N/A SCW '' (305mm) 7.50'' (191mm) 15.25'' (387mm) 16.25'' (413mm) N/A N/A SCW '' (330mm) 8.00'' (203mm) 17.50'' (445mm) 17.25'' (438mm) N/A N/A SCW '' (356mm) 8.50'' (216mm) 18.50'' (470mm) 19.00'' (483mm) N/A N/A SCW '' (381mm) 9.00'' (229mm) 19.00'' (483mm) 20.25'' (514mm) N/A N/A SCW '' (406mm) 9.50'' (241mm) 21.00'' (533mm) 21.50'' (546mm) N/A N/A Call factory for joints larger than 16 JOINT JOINT ALUMINUM FRAME EXPOSED SURFACE ANGLED ALUMINUM COVER PLATE EXPOSED SURFACE SFW (TYP.) SCW (TYP.) 2.38

139 SFW-S / SFW-B SCW-S / SCW-B Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T6) Turnbar Material - C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Bronze C28000 Muntz Metal ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Product Description: This surface mounted metal wall cover is designed for interior applications where low maintenance is desirable. Use This Cover For: Interior applications to match Allway metal floor covers. Interior applications where low maintenance is desirable. Performance Characteristics: Self-centering aluminum center plate spans joint and slides between retainer assemblies to allow movement when required. Cover can be painted to match wall finish. Standard Finishes: Bronze Satin Finish. Stainless Steel No. 4 Finish. Installation Guidelines: Install the retainer with the fasteners as supplied by C/S. This model also uses a turnbar assembly. There are some great tips in the complete C/S installation instructions. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

140 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SFW-400 S/B 4.00'' (102mm) 2.75'' (70mm) 7.25'' (184mm) 7.50'' (191mm) N/A N/A SFW-500 S/B 5.00'' (127mm) 2.75'' (70mm) 9.50'' (241mm) 10.50'' (267mm) N/A N/A SFW-600 S/B 6.00'' (152mm) 2.75'' (70mm) 9.50'' (241mm) 11.94'' (303mm) N/A N/A SFW-700 S/B 7.00'' (178mm) 2.75'' (70mm) 13.25'' (337mm) 13.50'' (343mm) N/A N/A SFW-800 S/B 8.00'' (203mm) 2.75'' (70mm) 14.75'' (375mm) 15.00'' (381mm) N/A N/A SFW-900 S/B 9.00'' (229mm) 2.75'' (70mm) 14.25'' (362mm) 16.50'' (419mm) N/A N/A SFW-1000 S/B 10.00'' (254mm) 2.75'' (70mm) 17.50'' (445mm) 17.94'' (456mm) N/A N/A SFW-1100 S/B 11.00'' (279mm) 2.75'' (70mm) 18.50'' (470mm) 19.50'' (495mm) N/A N/A SFW-1200 S/B 12.00'' (305mm) 2.75'' (70mm) 18.50'' (470mm) 21.00'' (533mm) N/A N/A SFW-1300 S/B 13.00'' (330mm) 2.75'' (70mm) 22.25'' (565mm) 22.50'' (572mm) N/A N/A SFW-1400 S/B 14.00'' (356mm) 2.75'' (70mm) 23.00'' (584mm) 23.94'' (608mm) N/A N/A SFW-1500 S/B 15.00'' (381mm) 2.75'' (70mm) 23.00'' (584mm) 25.50'' (648mm) N/A N/A SFW-1600 S/B 16.00'' (406mm) 2.75'' (70mm) 26.00'' (660mm) 27.00'' (686mm) N/A N/A SCW-400 S/B 4.00'' (102mm) 0.00'' (0mm) 5.50'' (140mm) 5.75'' (146mm) N/A N/A SCW-500 S/B 5.00'' (127mm) 0.00'' (0mm) 7.50'' (191mm) 7.50'' (191mm) N/A N/A SCW-600 S/B 6.00'' (152mm) 0.00'' (0mm) 8.75'' (222mm) 9.00'' (229mm) N/A N/A SCW-700 S/B 7.00'' (178mm) 5.00'' (127mm) 10.00'' (254mm) 10.25'' (260mm) N/A N/A SCW-800 S/B 8.00'' (203mm) 5.50'' (140mm) 11.25'' (286mm) 11.50'' (292mm) N/A N/A SCW-900 S/B 9.00'' (229mm) 6.00'' (152mm) 11.50'' (292mm) 12.75'' (324mm) N/A N/A SCW-1000 S/B 10.00'' (254mm) 6.50'' (165mm) 13.75'' (349mm) 14.00'' (356mm) N/A N/A SCW-1100 S/B 11.00'' (279mm) 7.00'' (178mm) 14.75'' (375mm) 15.25'' (387mm) N/A N/A SCW-1200 S/B 12.00'' (305mm) 7.50'' (191mm) 15.25'' (387mm) 16.25'' (413mm) N/A N/A SCW-1300 S/B 13.00'' (330mm) 8.00'' (203mm) 17.50'' (445mm) 17.25'' (438mm) N/A N/A SCW-1400 S/B 14.00'' (356mm) 8.50'' (216mm) 18.50'' (470mm) 19.00'' (483mm) N/A N/A SCW-1500 S/B 15.00'' (381mm) 9.00'' (229mm) 19.00'' (483mm) 20.25'' (514mm) N/A N/A SCW-1600 S/B 16.00'' (406mm) 9.50'' (241mm) 21.00'' (533mm) 21.50'' (546mm) N/A N/A Call factory for joints larger than 16 JOINT JOINT GYP. BOARD WALL (N.I.C.) CONTINOUS EXTRUDED ALUMINUM FRAME GYP. BOARD WALL (N.I.C.) BRONZE OR STAINLESS STEEL CENTER PLATE SPRING STEEL TURNBAR BRONZE OR STAINLESS STEEL CENTER PLATE 1 1/2" EXPOSED SURFACE EXPOSED SURFACE SFW-S/B (TYP.) SCW-S/B (TYP.) 2.40

141 LAF & LAFC Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T6) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Honeycomb panels Skins Core 3031-H14 Product Description: This Flush wall and ceiling cover is designed for large joints where minimal visibility is desired. Unique attachment design allows for thermal expansion and allows panel to disengage during a seismic event to prevent damage to surrounding walls. Use This Cover For: Large seismic joints where concealment is desired. Suitable for most wall finishes including demountable panel. Performance Characteristics: The LAF cover is factory primed and field painted to match almost any finish and disengages from wall on shock cords for full movement. Standard Finishes: Clear anodize on any exposed aluminum. Cover plate supplied with clear epoxy primer and can be painted to match adjacent wall finishes. Installation Guidelines: Attach the aluminum retainers to wall using mechanical fasteners. Cut finished panels to match retainers. Attach s-hook on back of panel to pre-tensioned shock cord. Panels are attached to retainers with heavy duty hook and loop fasteners. There are some great tips in the complete C/S installation instructions. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

142 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT LAF '' (102mm) 1.00'' (25mm) 8.00'' (203mm) 14.31'' (364mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (127mm) 1.00'' (25mm) 10.00'' (254mm) 15.31'' (389mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (152mm) 1.00'' (25mm) 12.00'' (305mm) 16.31'' (414mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (178mm) 1.00'' (25mm) 14.00'' (356mm) 17.31'' (440mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (203mm) 1.00'' (25mm) 16.00'' (406mm) 18.31'' (465mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (229mm) 1.00'' (25mm) 18.00'' (457mm) 19.31'' (491mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (254mm) 1.00'' (25mm) 20.00'' (508mm) 20.31'' (516mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (279mm) 1.00'' (25mm) 22.00'' (559mm) 21.31'' (541mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (305mm) 1.00'' (25mm) 24.00'' (610mm) 22.31'' (567mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (330mm) 1.00'' (25mm) 26.00'' (660mm) 23.31'' (592mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (356mm) 1.00'' (25mm) 28.00'' (711mm) 24.31'' (618mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (381mm) 1.00'' (25mm) 30.00'' (762mm) 25.31'' (643mm) 5.13'' (130mm) 0.63'' (16mm) LAF '' (406mm) 1.00'' (25mm) 32.00'' (813mm) 26.31'' (668mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (102mm) 2.50'' (64mm) 8.00'' (203mm) 9.13'' (232mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (127mm) 2.50'' (64mm) 10.00'' (254mm) 10.13'' (257mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (152mm) 2.50'' (64mm) 12.00'' (305mm) 11.13'' (283mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (178mm) 2.50'' (64mm) 14.00'' (356mm) 12.13'' (308mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (203mm) 2.50'' (64mm) 16.00'' (406mm) 13.13'' (333mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (229mm) 2.50'' (64mm) 18.00'' (457mm) 14.13'' (359mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (254mm) 2.50'' (64mm) 20.00'' (508mm) 15.13'' (384mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (279mm) 2.50'' (64mm) 22.00'' (559mm) 16.13'' (410mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (305mm) 2.50'' (64mm) 24.00'' (610mm) 17.13'' (435mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (330mm) 2.50'' (64mm) 26.00'' (660mm) 18.13'' (460mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (356mm) 2.50'' (64mm) 28.00'' (711mm) 19.13'' (486mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (381mm) 2.50'' (64mm) 30.00'' (762mm) 20.13'' (511mm) 5.13'' (130mm) 0.63'' (16mm) LAFC '' (406mm) 2.50'' (64mm) 32.00'' (813mm) 21.13'' (537mm) 5.13'' (130mm) 0.63'' (16mm) Call factory for joints larger than 16 JOINT HEIGHT HEIGHT ALUMINUM FRAME LAF COVER ASSEMBLY EXPOSED SURFACE LAF (TYP.) JOINT HEIGHT LAFC COVER ASSEMBLY EXPOSED SURFACE LAFC (TYP.) 2.42

143 LAS & LASC Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T6) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Honeycomb panels Skins Core 3031-H14 Product Description: This flush wall and ceiling cover is designed for large joints where minimal visibility is desired. Unique attachment design allows for thermal expansion and allows panel to disengage during a seismic event to prevent damage to surrounding walls. Use This Cover For: Large seismic joints where concealment is desired. Suitable for most wall finishes including demountable panel. Performance Characteristics: The LAS cover is factory primed can be field painted to match almost any finish and disengages from wall on shock cords for full movement. Standard Finishes: Clear anodize on any exposed aluminum. Cover plate supplied with clear epoxy primer and can be painted to match adjacent wall finishes. Installation Guidelines: Attach the aluminum retainers to wall using mechanical fasteners Cut finish panels to match retainers. Attach spring clip to back of panel connecting to pre-tensioned shock cord. Panels are attached to retainers with heavy duty hook and loop fasteners. There are some great tips in the complete C/S installation instructions. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

144 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT LAS '' (102mm) 1.00'' (25mm) 8.00'' (203mm) 11.00'' (279mm) N/A N/A LAS '' (127mm) 1.00'' (25mm) 10.00'' (254mm) 12.00'' (305mm) N/A N/A LAS '' (152mm) 1.00'' (25mm) 12.00'' (305mm) 13.00'' (330mm) N/A N/A LAS '' (178mm) 1.00'' (25mm) 14.00'' (356mm) 14.00'' (356mm) N/A N/A LAS '' (203mm) 1.00'' (25mm) 16.00'' (406mm) 15.00'' (381mm) N/A N/A LAS '' (229mm) 1.00'' (25mm) 18.00'' (457mm) 16.00'' (406mm) N/A N/A LAS '' (254mm) 1.00'' (25mm) 20.00'' (508mm) 17.00'' (432mm) N/A N/A LAS '' (279mm) 1.00'' (25mm) 22.00'' (559mm) 18.00'' (457mm) N/A N/A LAS '' (305mm) 1.00'' (25mm) 24.00'' (610mm) 19.00'' (483mm) N/A N/A LAS '' (330mm) 1.00'' (25mm) 26.00'' (660mm) 20.00'' (508mm) N/A N/A LAS '' (356mm) 1.00'' (25mm) 28.00'' (711mm) 21.00'' (533mm) N/A N/A LAS '' (381mm) 1.00'' (25mm) 30.00'' (762mm) 22.00'' (559mm) N/A N/A LAS '' (406mm) 1.00'' (25mm) 32.00'' (813mm) 23.00'' (584mm) N/A N/A LASC '' (102mm) 2.50'' (64mm) 8.00'' (203mm) 7.50'' (191mm) N/A N/A LASC '' (127mm) 2.50'' (64mm) 10.00'' (254mm) 8.50'' (216mm) N/A N/A LASC '' (152mm) 2.50'' (64mm) 12.00'' (305mm) 9.50'' (241mm) N/A N/A LASC '' (178mm) 2.50'' (64mm) 14.00'' (356mm) 10.50'' (267mm) N/A N/A LASC '' (203mm) 2.50'' (64mm) 16.00'' (406mm) 11.50'' (292mm) N/A N/A LASC '' (229mm) 2.50'' (64mm) 18.00'' (457mm) 12.50'' (318mm) N/A N/A LASC '' (254mm) 2.50'' (64mm) 20.00'' (508mm) 13.50'' (343mm) N/A N/A LASC '' (279mm) 2.50'' (64mm) 22.00'' (559mm) 14.50'' (368mm) N/A N/A LASC '' (305mm) 2.50'' (64mm) 24.00'' (610mm) 15.50'' (394mm) N/A N/A LASC '' (330mm) 2.50'' (64mm) 26.00'' (660mm) 16.50'' (419mm) N/A N/A LASC '' (356mm) 2.50'' (64mm) 28.00'' (711mm) 17.50'' (445mm) N/A N/A LASC '' (381mm) 2.50'' (64mm) 30.00'' (762mm) 18.50'' (470mm) N/A N/A LASC '' (406mm) 2.50'' (64mm) 32.00'' (813mm) 19.50'' (495mm) N/A N/A Call factory for joints larger than 16 JOINT LAS COVER ASSEMBLY EXPOSED SURFACE LAS (TYP.) JOINT S-HOOK ALUMINUM FRAME WALL (N.I.C.) ALUMINUM LAS RETAINER SHOCK CORD HOOK AND LOOP ATTACHMENT LAS COVER ASSEMBLY EXPOSED SURFACE LASC (TYP.) 2.44

145 Section 3 - Ceiling Covers Joint Size Page Nos. Joint Size Page Nos. One piece, easily installed 1" to 4" (3.3, 3.4) Double Reveal 5" to 16" (3.15, 3.16) 1" to 2" (3.5, 3.6) Metal 4" to 16" (3.17, 3.18) Gasketed Single Gasket 3" to 5" 6" to 10" (3.7, 3.8) (3.9, 3.10) Surface Plate w/ Turnbar 4" to 9" (3.19, 3.20) 2" to 4" 5" to 10" (3.11, 3.12) (3.13, 3.14) Reference Information Wall Joint models cross reference to ceiling applications

146 Section 3 - Ceiling Covers In the ceiling section, you will find many different types and styles of ceiling covers that are designed for different joint sizes, degrees of movement and a variety of substrate materials. Some ceiling covers are designed to integrate with certain wall covers, while others are simply designed for the smallest exposed surface possible. With so many styles to choose from, you re certain to find a cover that gives you the results you are looking for. Gasketed Joint Covers Ceiling systems can accommodate expansion joint sizes of 1" to 10". Offer a minimal exposed surface and are available in flush or serrated profiles. Santoprene gaskets are replaceable and are typically available in a variety of standard and custom colors to match adjacent finishes. Metal Joint Covers Capable of withstanding simple expansion and contraction as well as larger movements. Seismic metal ceiling covers are available with aluminum or Kynar painted center plates. 3.2

147 HC & HCW Series Technical Data: Dual Durometer 80 Shore A / 97 Shore A, ASTM D2000 Available in 1 standard color (white). Product Description: This ceiling cover is designed for interior applications where low maintenance is desirable. Use This Cover For: Interior applications in acoustical ceilings. Performance Characteristics: This simple ceiling cover has a ribbed center that allows for movement. Standard Finishes: Cover only available in white. Installation Guidelines: Fasten the cover onto ceiling tracks using the C/S supplied screws. Lay adjacent ceiling tiles into place. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

148 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT HC '' (25mm) 0.00'' (0mm) 6.00'' (152mm) 1.00'' (25mm) N/A N/A HC '' (51mm) 0.00'' (0mm) 6.00'' (152mm) 2.00'' (51mm) N/A N/A HC '' (76mm) 0.00'' (0mm) 10.00'' (254mm) 3.00'' (76mm) N/A N/A HC '' (102mm) 0.00'' (0mm) 10.00'' (254mm) 4.00'' (102mm) N/A N/A HCW '' (25mm) 0.00'' (0mm) 6.00'' (152mm) 1.50'' (38mm) N/A N/A HCW '' (51mm) 0.00'' (0mm) 6.00'' (152mm) 2.50'' (64mm) N/A N/A HCW '' (76mm) 0.00'' (0mm) 10.00'' (254mm) 3.50'' (89mm) N/A N/A HCW '' (102mm) 0.00'' (0mm) 10.00'' (254mm) 4.50'' (114mm) N/A N/A SUSPENDED CEILING JOINT EXPOSED SURFACE HC (TYP.) JOINT SUSPENDED CEILING EXPOSED SURFACE HCW (TYP.) 3.4

149 FCF & FCFC 100/200 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Dual Durometer 65 Shore A, 90 Shore A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, flush ceiling cover is ideal for applications where minimal visual impact is preferred. These models are also designed to match flush Thinline covers used in the wall. Use This Cover For: Ceiling applications to align with and match flush Thinline covers used on the wall. Suitable for acoustical tile ceiling construction frame configuration available to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The dual durometer thermoplastic gasket has rigid edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The softer center section of the gasket allows full movement without the need for grooves in the face surface which collect dirt. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the retainer to the ceiling with fasteners supplied by C/S. Insert the rigid edges of the primary seal into the retainer. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

150 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FCF '' (25mm) 0.60'' (15mm) 1.25'' (32mm) 0.81'' (21mm) N/A N/A FCF '' (51mm) 0.60'' (14mm) 2.50'' (64mm) 1.63'' (41mm) N/A N/A FCFC '' (25mm) 0.75'' (19mm) 1.25'' (32mm) 1.00'' (25mm) N/A N/A FCFC '' (51mm) 0.75'' (19mm) 2.50'' (64mm) 1.75'' (44mm) N/A N/A SUSPENDED CEILING (N.I.C.) JOINT ALUMINUM FRAME SUSPENDED CEILING JOINT FLEXIBLE GASKET EXPOSED SURFACE EXPOSED SURFACE FCF-100 FCF-200 JOINT SUSPENDED CEILING (N.I.C.) SUSPENDED CEILING JOINT ALUMINUM CEILING FAME FLEXIBLE GASKET EXPOSED SURFACE ALUMINUM WALL FRAME EXPOSED SURFACE FCFC-100 FCFC

151 FCF & FCFC 300/500 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, flush ceiling cover is ideal for applications where minimal visual impact is preferred. These models are also designed to match flush Thinline covers used in the wall. Use This Cover For: Ceiling applications to align with and match flush Thinline covers used on the wall. Suitable for acoustical tile ceiling construction frame configuration available to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket flexes to allow full movement. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the retainer to the ceiling with fasteners supplied by C/S. Insert the edges of the primary seal into the retainer. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

152 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FCF '' (76mm) 1.25'' (32mm) 4.50'' (114mm) 3.00'' (76mm) N/A N/A FCF '' (102mm) 1.25'' (32mm) 6.00'' (152mm) 4.00'' (102mm) N/A N/A FCF '' (127mm) 1.25'' (32mm) 7.50'' (191mm) 5.00'' (127mm) N/A N/A FCFC '' (76mm) 1.25'' (32mm) 4.50'' (114mm) 3.00'' (76mm) N/A N/A FCFC '' (102mm) 1.25'' (32mm) 6.00'' (152mm) 4.00'' (102mm) N/A N/A FCFC '' (127mm) 1.25'' (32mm) 7.50'' (191mm) 5.00'' (127mm) N/A N/A JOINT ALUMINUM FRAME SUSPENDED CEILING (BY OTHERS) EXPOSED SURFACE FLEXIBLE PRIMARY SEAL FCF-300/500 ALUMINUM FRAME JOINT SUSPENDED CEILING (BY OTHERS) FLEXIBLE PRIMARY SEAL EXPOSED SURFACE ALUMINUM FRAME FCFC-300/

153 FCF & FCFC 600/1000 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, flush ceiling cover is ideal for applications where minimal visual impact is preferred. These models are also designed to match flush Thinline covers used in the wall. Use This Cover For: Ceiling applications to align with and match flush Thinline covers used on the wall. Suitable for acoustical tile ceiling construction frame configuration available to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum retainers. This prevents hairline gaps from opening between the gasket and retainer ensuring a hygienic seal. The center section of the gasket flexes to allow full movement. The gaskets are supported with an aluminum center mullion and turnbars (7 and larger). Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the retainer to the ceiling with fasteners supplied by C/S. Insert the edges of the primary seal into the retainer. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

154 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FCF '' (152mm) 1.75'' (44mm) 9.00'' (229mm) 6.00'' (152mm) N/A N/A FCF '' (178mm) 2.50'' (64mm) 10.50'' (267mm) 7.00'' (178mm) N/A N/A FCF '' (203mm) 2.50'' (64mm) 12.00'' (305mm) 8.00'' (203mm) N/A N/A FCF '' (229mm) 2.50'' (64mm) 13.50'' (343mm) 9.00'' (229mm) N/A N/A FCF '' (254mm) 2.50'' (64mm) 15.00'' (381mm) 10.00'' (254mm) N/A N/A FCFC '' (152mm) 1.75'' (44mm) 9.00'' (229mm) 6.00'' (152mm) N/A N/A FCFC '' (178mm) 2.50'' (64mm) 10.50'' (267mm) 7.00'' (178mm) N/A N/A FCFC '' (203mm) 2.50'' (64mm) 12.00'' (305mm) 8.00'' (203mm) N/A N/A FCFC '' (229mm) 2.50'' (64mm) 13.50'' (343mm) 9.00'' (229mm) N/A N/A FCFC '' (254mm) 2.50'' (64mm) 15.00'' (381mm) 10.00'' (254mm) N/A N/A NOTE: No turnbar required for 6 models. TURNBAR ASSEMBLY JOINT ALUMINUM FRAME SUSPENDED CEILING (BY OTHERS) EXPOSED SURFACE FLEXIBLE PRIMARY SEAL ALUMINUM CENTER MULLION FCF-600/1000 JOINT ALUMINUM FRAME TURNBAR ASSEMBLY SUSPENDED CEILING (BY OTHERS) ALUMINUM CENTER MULLION EXPOSED SURFACE FLEXIBLE PRIMARY SEAL FCFC-600/

155 FCS & FCSC 200/400 Series Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, ceiling cover is ideal for applications where minimal visual impact is preferred. These models are also designed to match Thinline covers used on the wall. The gaskets used for FCS offer more expansion than the FCF covers. Use This Cover For: Ceiling applications to align with and match Thinline covers used on the wall. Suitable for acoustical tile ceiling construction frame configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The center section of the gasket is ribbed to allow for movement up to 100%. Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the retainer to the ceiling with fasteners supplied by C/S. Insert the edges of the primary seal into the retainer. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

156 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FCS '' (51mm) 1.25'' (32mm) 4.00'' (102mm) 2.00'' (51mm) N/A N/A FCS '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 3.00'' (76mm) N/A N/A FCS '' (102mm) 1.25'' (32mm) 8.00'' (203mm) 4.00'' (102mm) N/A N/A FCSC '' (51mm) 1.25'' (32mm) 4.00'' (102mm) 2.00'' (51mm) N/A N/A FCSC '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 3.00'' (76mm) N/A N/A FCSC '' (102mm) 1.25'' (32mm) 8.00'' (203mm) 4.00'' (102mm) N/A N/A ALUMINUM FRAME JOINT ALUMINUM FRAME JOINT SUSPENDED CEILING (BY OTHERS) EXPOSED SURFACE FLEXIBLE PRIMARY SEAL SUSPENDED CEILING (BY OTHERS) EXPOSED SURFACE FLEXIBLE PRIMARY SEAL FCS-200 FCS-300/400 ALUMINUM FRAME JOINT ALUMINUM FRAME JOINT SUSPENDED CEILING (BY OTHERS) FLEXIBLE PRIMARY SEAL EXPOSED SURFACE ALUMINUM FRAME SUSPENDED CEILING (BY OTHERS) FLEXIBLE PRIMARY SEAL EXPOSED SURFACE ALUMINUM FRAME FCSC-200 FCSC-300/

157 FCS & FCSC 500/1000 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer 70 Shore A, ASTM D2000 Available in 4 colors. Product Description: This single gasket, ceiling cover is ideal for applications where minimal visual impact is preferred. These models are also designed to match Thinline covers used on the wall. The gaskets used for FCS offer more expansion than the FCF covers. Use This Cover For: Ceiling applications to align with and match Thinline covers used on the wall. Suitable for acoustical tile ceiling construction frame configuration variable to suit flat and corner applications. Where hygiene is important. Performance Characteristics: The thermoplastic gasket has edges designed to lock into the aluminum side frames. This prevents hairline gaps from opening between the gasket and frame ensuring a hygienic seal. The center section of the gasket is ribbed to allow for movement up to 100%. The gaskets are supported with an aluminum center mullion and turnbars (7 and larger). Standard Finishes: Mill finish on any exposed aluminum. Gasket is available in Black, White, Gray, & Greige. Installation Guidelines: Attach the retainer to the ceiling with fasteners supplied by C/S. Insert the edges of the primary seal into the retainer. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

158 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT FCS '' (127mm) 1.75'' (44mm) 10.00'' (254mm) 5.00'' (127mm) N/A N/A FCS '' (152mm) 1.75'' (44mm) 12.00'' (305mm) 6.00'' (152mm) N/A N/A FCS '' (178mm) 2.50'' (64mm) 14.00'' (356mm) 7.00'' (178mm) N/A N/A FCS '' (203mm) 2.50'' (64mm) 16.00'' (406mm) 8.00'' (203mm) N/A N/A FCS '' (229mm) 2.50'' (64mm) 18.00'' (457mm) 9.00'' (229mm) N/A N/A FCS '' (254mm) 2.50'' (64mm) 20.00'' (508mm) 10.00'' (254mm) N/A N/A FCSC '' (127mm) 1.75'' (44mm) 10.00'' (254mm) 5.00'' (127mm) N/A N/A FCSC '' (152mm) 1.75'' (44mm) 12.00'' (305mm) 6.00'' (152mm) N/A N/A FCSC '' (178mm) 2.50'' (64mm) 14.00'' (356mm) 7.00'' (178mm) N/A N/A FCSC '' (203mm) 2.50'' (64mm) 16.00'' (406mm) 8.00'' (203mm) N/A N/A FCSC '' (229mm) 2.50'' (64mm) 18.00'' (457mm) 9.00'' (229mm) N/A N/A FCSC '' (254mm) 2.50'' (64mm) 20.00'' (508mm) 10.00'' (254mm) N/A N/A NOTE: No turnbar required for 5 and 6 models. TURNBAR ASSEMBLY JOINT ALUMINUM FRAME SUSPENDED CEILING (BY OTHERS) EXPOSED SURFACE FLEXIBLE PRIMARY SEAL ALUMINUM CENTER MULLION FCS-500/1000 ALUMINUM FRAME JOINT TURNBAR ASSEMBLY SUSPENDED CEILING (BY OTHERS) EXPOSED SURFACE ALUMINUM CENTER MULLION FLEXIBLE PRIMARY SEAL FCSC-500/

159 SGC & SGCC Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Turnbar Material - C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Product Description: This self-centering, flush ceiling cover is ideal for areas with larger movement requirements. This model is also designed to match flush Twinline covers used on the wall. Use This Cover For: Ceiling applications to match flush Twinline covers used on the wall. Suitable for most ceiling finishes. Where hygiene is important. Performance Characteristics: Durable self-centering aluminum plate spans joint opening and can be painted to match nearly any finish. Standard Finishes: Clear anodize finish on any exposed aluminum. Cover plate can be painted to match adjacent ceiling finishes. Installation Guidelines: The ceiling structure must be prepared to receive the joint cover. It must be plumb, square, and level across the width of the joint. Attach the aluminum frames to ceiling using mechanical fasteners. This model also features a turnbar assembly. There are some great tips in the complete C/S installation instructions. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

160 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SGC '' (127mm) 2.75'' (70mm) 9.00'' (229mm) 13.75'' (349mm) 3.50'' (89mm) 0.63'' (16mm) SGC '' (152mm) 2.75'' (70mm) 9.25'' (235mm) 14.75'' (375mm) 3.50'' (89mm) 0.63'' (16mm) SGC '' (178mm) 2.75'' (70mm) 12.00'' (305mm) 16.75'' (425mm) 4.00'' (102mm) 0.63'' (16mm) SGC '' (203mm) 2.75'' (70mm) 13.00'' (330mm) 17.75'' (451mm) 4.00'' (102mm) 0.63'' (16mm) SGC '' (229mm) 2.75'' (70mm) 14.00'' (356mm) 19.75'' (502mm) 4.50'' (114mm) 0.63'' (16mm) SGC '' (254mm) 2.75'' (70mm) 16.00'' (406mm) 20.75'' (527mm) 4.50'' (114mm) 0.63'' (16mm) SGC '' (279mm) 2.75'' (70mm) 18.00'' (457mm) 22.75'' (578mm) 5.00'' (127mm) 0.63'' (16mm) SGC '' (305mm) 2.75'' (70mm) 18.50'' (470mm) 23.75'' (603mm) 5.00'' (127mm) 0.63'' (16mm) SGC '' (330mm) 2.75'' (70mm) 21.00'' (533mm) 25.75'' (654mm) 5.50'' (140mm) 0.63'' (16mm) SGC '' (356mm) 2.75'' (70mm) 22.00'' (559mm) 26.75'' (679mm) 5.50'' (140mm) 0.63'' (16mm) SGC '' (381mm) 2.75'' (70mm) 22.75'' (578mm) 28.75'' (730mm) 6.00'' (152mm) 0.63'' (16mm) SGC '' (406mm) 2.75'' (70mm) 25.00'' (635mm) 29.75'' (756mm) 6.00'' (152mm) 0.63'' (16mm) SGCC '' (127mm) 3.75'' (95mm) 7.00'' (178mm) 9.38'' (238mm) 3.50'' (89mm) 0.63'' (16mm) SGCC '' (152mm) 4.25'' (108mm) 7.50'' (191mm) 10.38'' (264mm) 3.50'' (89mm) 0.63'' (16mm) SGCC '' (178mm) 5.00'' (127mm) 9.50'' (241mm) 11.88'' (302mm) 4.00'' (102mm) 0.63'' (16mm) SGCC '' (203mm) 5.50'' (140mm) 10.50'' (267mm) 12.88'' (327mm) 4.00'' (102mm) 0.63'' (16mm) SGCC '' (229mm) 6.00'' (152mm) 11.50'' (292mm) 14.38'' (365mm) 4.50'' (114mm) 0.63'' (16mm) SGCC '' (254mm) 6.50'' (165mm) 13.00'' (330mm) 15.38'' (391mm) 4.50'' (114mm) 0.63'' (16mm) SGCC '' (279mm) 7.00'' (178mm) 14.50'' (368mm) 16.88'' (429mm) 5.00'' (127mm) 0.63'' (16mm) SGCC '' (305mm) 7.50'' (191mm) 15.25'' (387mm) 17.88'' (454mm) 5.00'' (127mm) 0.63'' (16mm) SGCC '' (330mm) 8.00'' (203mm) 17.00'' (432mm) 19.38'' (492mm) 5.50'' (140mm) 0.63'' (16mm) SGCC '' (356mm) 8.50'' (216mm) 18.00'' (457mm) 20.38'' (518mm) 5.50'' (140mm) 0.63'' (16mm) SGCC '' (381mm) 9.00'' (229mm) 18.75'' (476mm) 21.88'' (556mm) 6.00'' (152mm) 0.63'' (16mm) SGCC '' (406mm) 9.50'' (241mm) 20.50'' (521mm) 22.88'' (581mm) 6.00'' (152mm) 0.63'' (16mm) For larger size joints, call (800) or visit JOINT SUSPENDED CEILING HEIGHT HEIGHT EXPOSED SURFACE SGC (TYP.) JOINT SUSPENDED CEILING HEIGHT EXPOSED SURFACE SGCC (TYP.) 3.16

161 SFC & SCC Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105- T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Duroflex Gasket Single Durometer 80 Shore A, ASTM D2000 Color Gray Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Product Description: This surface mounted metal ceiling cover is designed for interior applications where low maintenance is desirable Use This Cover For: Interior applications to match Allway metal wall covers. Interior applications where low maintenance is desirable. Performance Characteristics: Self-centering aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Cover can be painted to match wall finish. Standard Finishes: Clear anodize finish. Kynar paint and bronze or stainless steel top plates are also available. Installation Guidelines: Install the frame with the fasteners as supplied by C/S. This model also uses a turnbar assembly. There are some great tips in the complete C/S installation instructions. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

162 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SFC '' (102mm) 2.75'' (70mm) 7.25'' (184mm) 7.50'' (191mm) N/A N/A SFC '' (127mm) 2.75'' (70mm) 9.50'' (241mm) 10.50'' (267mm) N/A N/A SFC '' (152mm) 2.75'' (70mm) 9.50'' (241mm) 11.94'' (303mm) N/A N/A SFC '' (178mm) 2.75'' (70mm) 13.25'' (337mm) 13.50'' (343mm) N/A N/A SFC '' (203mm) 2.75'' (70mm) 14.75'' (375mm) 15.00'' (381mm) N/A N/A SFC '' (229mm) 2.75'' (70mm) 14.25'' (362mm) 16.50'' (419mm) N/A N/A SFC '' (254mm) 2.75'' (70mm) 17.50'' (445mm) 17.94'' (456mm) N/A N/A SFC '' (279mm) 2.75'' (70mm) 18.50'' (470mm) 19.50'' (495mm) N/A N/A SFC '' (305mm) 2.75'' (70mm) 18.50'' (470mm) 21.00'' (533mm) N/A N/A SFC '' (330mm) 2.75'' (70mm) 22.25'' (565mm) 22.50'' (572mm) N/A N/A SFC '' (356mm) 2.75'' (70mm) 23.00'' (584mm) 23.94'' (608mm) N/A N/A SFC '' (381mm) 2.75'' (70mm) 23.00'' (584mm) 25.50'' (648mm) N/A N/A SFC '' (406mm) 2.75'' (70mm) 26.00'' (660mm) 27.00'' (686mm) N/A N/A SCC '' (102mm) 0.00'' (0mm) 5.50'' (140mm) 5.75'' (146mm) N/A N/A SCC '' (127mm) 0.00'' (0mm) 7.50'' (191mm) 7.50'' (191mm) N/A N/A SCC '' (152mm) 0.00'' (0mm) 8.75'' (222mm) 9.00'' (229mm) N/A N/A SCC '' (178mm) 5.00'' (127mm) 10.00'' (254mm) 10.25'' (260mm) N/A N/A SCC '' (203mm) 5.50'' (140mm) 11.25'' (286mm) 11.50'' (292mm) N/A N/A SCC '' (229mm) 6.00'' (152mm) 11.50'' (292mm) 12.75'' (324mm) N/A N/A SCC '' (254mm) 6.50'' (165mm) 13.75'' (349mm) 14.00'' (356mm) N/A N/A SCC '' (279mm) 7.00'' (178mm) 14.75'' (375mm) 15.25'' (387mm) N/A N/A SCC '' (305mm) 7.50'' (191mm) 15.25'' (387mm) 16.50'' (419mm) N/A N/A SCC '' (330mm) 8.00'' (203mm) 17.50'' (445mm) 17.25'' (438mm) N/A N/A SCC '' (356mm) 8.50'' (216mm) 18.50'' (470mm) 19.00'' (483mm) N/A N/A SCC '' (381mm) 9.00'' (229mm) 19.00'' (483mm) 20.25'' (514mm) N/A N/A SCC '' (406mm) 9.50'' (241mm) 21.00'' (533mm) 21.50'' (546mm) N/A N/A For larger size joints, call (800) or visit JOINT SUSPENDED CEILING EXPOSED SURFACE SFC (TYP.) SUSPENDED CEILING JOINT EXPOSED SURFACE SCC (TYP.) 3.18

163 SFC-S & SCC-S Series SFC-B & SCC-B Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A- T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection) Bronze C28000 Muntz Metal ASTM B455 Stainless Steel Type 304 ASTM A167, A240A, A240M Product Description: This surface mounted metal ceiling cover is designed for interior applications where low maintenance is desirable Use This Cover For: Interior applications to match Allway metal wall covers. Interior applications where low maintenance is desirable. Performance Characteristics: Self-centering aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Cover can be painted to match wall finish. Standard Finishes: Bronze Satin Finish. Stainless Steel No. 4 Finish. Installation Guidelines: Install the frame with the fasteners as supplied by C/S. This model also uses a turnbar assembly. There are some great tips in the complete C/S installation instructions. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

164 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SFC-400 S/B 4.00'' (102mm) 2.75'' (70mm) 7.25'' (184mm) 7.50'' (191mm) N/A N/A SFC-500 S/B 5.00'' (127mm) 2.75'' (70mm) 9.50'' (241mm) 10.50'' (267mm) N/A N/A SFC-600 S/B 6.00'' (152mm) 2.75'' (70mm) 9.50'' (241mm) 11.94'' (303mm) N/A N/A SFC-700 S/B 7.00'' (178mm) 2.75'' (70mm) 13.25'' (337mm) 13.50'' (343mm) N/A N/A SFC-800 S/B 8.00'' (203mm) 2.75'' (70mm) 14.75'' (375mm) 15.00'' (381mm) N/A N/A SFC-900 S/B 9.00'' (229mm) 2.75'' (70mm) 14.25'' (362mm) 16.50'' (419mm) N/A N/A SCC-400 S/B 4.00'' (102mm) 0.00'' (0mm) 5.50'' (140mm) 5.75'' (146mm) N/A N/A SCC-500 S/B 5.00'' (127mm) 0.00'' (0mm) 7.50'' (191mm) 7.50'' (191mm) N/A N/A SCC-600 S/B 6.00'' (152mm) 0.00'' (0mm) 8.75'' (222mm) 9.00'' (229mm) N/A N/A SCC-700 S/B 7.00'' (178mm) 5.00'' (127mm) 10.00'' (254mm) 10.25'' (260mm) N/A N/A SCC-800 S/B 8.00'' (203mm) 5.50'' (140mm) 11.25'' (286mm) 11.50'' (292mm) N/A N/A SCC-900 S/B 9.00'' (229mm) 6.00'' (152mm) 11.50'' (292mm) 12.75'' (324mm) N/A N/A WALL (N.I.C.) SUSPENDED CEILING (N.I.C.) JOINT CONTINUOUS GALVANIZED STEEL BACKER PLATE ON METAL STUDS (N.I.C.).090 FORMED STAINLESS STEEL OR BRONZE CENTER PLATE EXPOSED SURFRACE SFC-S/B (TYP.) JOINT SUSPENDED CEILING (N.I.C.) CONTINOUS EXTRUDED ALUMINUM FRAME.090 FORMED STAINLESS STEEL OR BRONZE CENTER PLATE EXPOSED SURFACE SCC-S/B (TYP.) 3.20

165 CS Expansion Joint Covers: The following wall covers can also be used in ceiling conditions: AFW & AFWC Various finishes AFW-B & AFWC-B Various finishes AFW-S & AFWC-S Various finishes ASM & ASMC Various finishes ASM-B & ASMC-B Various finishes ASM-S & ASMC-S Various finishes FWF & FWFC Gyp. only , 2.9, & 2.13 FWF-M & FWFC-M Various finishes , 2.11 & 2.15 FWS & FWSC Gyp. only & 2.21 FWS-M & FWSC-M Various finishes & 2.23 GTW & GTWC Various finishes LAF & LAFC Various finishes LAS & LASC Various finishes

166 Section 4 - Seismic Corridor Covers Joint Size Page Nos. Corridor Cover MACC Series Factory Designed for project requirements (4.3, 4.4) 4.1

167 Section 4 - Seismic Corridor Covers The MACC covers are designed for larger joint openings that require extreme amounts of movement in all horizontal directions. The cover also allows for certain amounts of vertical movement that can typically occur in base isolated structures. The floor portion is set up to receive thinner floor finishes like VCT and carpet. The wall and ceiling is a frame construction that allows for drywall to be installed, which visually integrates the cover into the design. Unlike similar systems, the MACC has numerous safety features built in that prevent damage to surrounding construction and injuries to individuals both during and after a seismic event. When interior corridors traverse a seismic joint in a base isolated structure, a three dimensional cover system is necessary to accommodate significant four-way movement. Total system includes wall and ceiling covers attached to a structural frame which is supported off the floor structure. The design ensures that the entire assembly moves as one unit during an earthquake. Meets ASTM 1399 cycle test requirement including the requirement for witnessing the cycle testing of customized cover applications. 4.2

168 MACC Series Product Highlights OSHPD approved design. Complies with ASTM E1399. Fire rating available; compliant with UL Floor covers designed to accept variety of finishes. Wall and ceilings to be finished with drywall. Virtually any joint size/movement capability can be accommodated. Performance Characteristics: This system allows full access between base isolated and fixed structures. It is perfect for areas where egress is necessary during an earthquake and where up to 100% movement in four directions is required. Because base isolated structures are free to move in any horizontal direction, they create distinct challenges for the design of the seismic joint covers. The C/S solution for base isolated structures is an integrated assembly approach with floor, wall and ceiling covers connected and moving in unison. This Gyrometric System, or cab assembly, provides full movement of up to 100% in any direction. The floor cover may be used independently of the wall and ceiling covers for lineal applications where lateral shear is a problem. de Young Museum, CA Installation Guidelines: This cover system is designed on a job to job basis. Contact the factory for design and installation guidelines catered to your project. To download detail, specs & photos visit For technical and design assistance call

169 How the Gyrometric Cover Works CENTER PAN LOCKED INTO AND GUIDED BY TRACK AT BASE OF SIDE WALLS Full Open (During Tension) During an event in the expansion or tension mode, the cab slides fully out. THE SPINE KEEPS THE CAB FROM RACKING DURING SEISMIC MOVEMENT (RUNS PERPENDICULAR TO JOINT OPENINGS) Full Closed (During Compression) During an event in the contraction or compressionmode, the cab slides fully into the adjoining structure. Lateral Shear The cab is attached to the fixed structure by means of a friction-free sliding track assembly to allow full lateral shear between buildings. 4.4

170 Section 5 - Exterior Covers Joint Size Page Nos. Joint Size Page Nos. 2" to 5" (5.3, 5.4) 6" to 10" (5.5, 5.6) 11" to 16" (5.7, 5.8) Metal 1" to 2" 3" to 16" (5.23, 5.24) (5. 25, 5.26) Gasketed 3" to 4" (5.9, 5.10) 5" to 10" (5.11, 5.12) 11" to 16" (5.13, 5.14) Wall Accepts Finishes 8" to 34" ( ) Wall Silicon 1" to 8" (5.15, 5.16) Bellows ( ) Metal ( ) (5.37, 5.38) (5.39, 5.40) Metal 2" to 16" 1" to 8" Roof 1" to 2" 3" to 16" 4" to 16" (5.21, 5.22) Factory Designed for project requirements (5.41, 5.42) See pages 5-41 through 5-48 for transitional details. 5.1

171 Section 5 -Exterior Covers In the exterior covers section, you will find many different types and styles of wall and roof covers that are designed for different joint sizes, degrees of movement and a variety of substrate materials. All exterior covers are designed to be watertight and C/S can even supply factory-fabricated transitions to help maintain the water integrity at those tricky locations. Whether you are looking for something simple to provide waterproofing or something that can receive your finish materials and disappear into the wall, we have a cover that will meet your needs. Wall Covers Gasketed System Exterior vertical seals are available in flush or serrated profile. These systems are flexible and allow for multi-directional movement. Flush seals can accommodate ±50% movement. Serrated seals allow for 100% movement. Allows for multi -directional movement, such as tension, compression, lateral shear and some vertical movement. Accepts Finishes Combine a vertical pan system to accommodate lightweight field-applied finish from almost total concealment of exterior expansion joints. Automatically gravity closed after a seismic event. Provides a nearly total concealment of exterior expansion joint, resulting in a clean and aesthetically pleasing joint. Roof Covers Flexile Bellow System Flexible bellows-style covers are ideal for intricate transitions and are a more economical choice for joints under 6". Lateral shear capabilities and easy installation. Metal System Aluminum roof covers are suitable for joints where durability is an issue. 5.2

172 SF 200/500 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Santoprene Primary Seal Single Durometer: 70 Shore A, ASTM D2000 Color: 4 standard Brittle Point: -76 F Ozone Resistance: No Cracks, ASTM D1149 UV Resistance: Very Good Secondary Seal Material PVC, ASTM D2000 Durometer 65 Shore A Product Description: SF is a gasketed exterior wall cover comprised of extruded aluminum frames, a Santoprene primary seal and a PVC secondary seal. This seal is designed to accommodate 50% movement. Use This Cover For: Exterior vertical applications where weather protection is critical. Frames designed to attach to most exterior finishes. 2" to 5" joint sizes with multi-directional movement. Factory welded transitions available. Four standard gasket colors. Performance Characteristics: Flush profile, colorable seals for exterior applications, expand and compress during movement, while providing a weather tight seal. Standard Finishes: Gasket is available in Black, White, Gray and Greige. Custom colors available. Installation Guidelines: No blockouts required. The joint width should be consistent and smooth, respective to its nominal size. Apply butyl tape to aluminum frame and attach inside joint opening with C/S supplied fasteners. Apply sealant to aluminum frames and insert secondary seal and primary seal. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

173 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SF '' (51mm) 1.25'' (32mm) 3.00'' (76mm) 2.00'' (51mm) N/A N/A SF '' (76mm) 1.25'' (32mm) 4.50'' (114mm) 3.00'' (76mm) N/A N/A SF '' (102mm) 1.25'' (32mm) 6.00'' (152mm) 4.00'' (102mm) N/A N/A SF '' (127mm) 1.25'' (32mm) 7.50'' (191mm) 5.00'' (127mm) N/A N/A CONTINUOUS ALUMINUM FRAME 2" CONTINUOUS PVC SECONDARY SEAL APPLY SIKAFLEX 1A IN RECEIVER PRIOR TO INSTALLING SECONDARY SEAL JOINT BUTYL CAULK 1/4"x1 3/4" HEX HD WEDGE BOLT WITH SEALING WASHER 18" O.C. FLEXIBLE PRIMARY SEAL 1/4" APPLY SIKAFLEX 1A IN RECEIVER PRIOR TO INSTALLING PRIMARY SEAL FLEXIBLE PRIMARY SEAL EXPOSED SURFACE SF-200 SF-300/500 CONTINUOUS ALUMINUM FRAME C/S SUPPLIED ADHESIVE 2" CONTINUOUS PVC SECONDARY SEAL APPLY SIKAFLEX 1A IN RECEIVER PRIOR TO INSTALLING SECONDARY SEAL 1/4"x1 3/4" HEX HD WEDGE BOLT WITH SEALING WASHER 18" O.C. JOINT FLEXIBLE PRIMARY SEAL 1/4" BUTYL CAULK APPLY SIKAFLEX 1A IN RECEIVER PRIOR TO INSTALLING PRIMARY SEAL C/S SUPPLIED ADHESIVE FLEXIBLE PRIMARY GASKET EXPOSED SURFACE SF-200 (Corner) SF-300/500 (Corner) 5.4

174 SF 600/1000 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Santoprene Primary Seal Single Durometer: 70 Shore A, ASTM D2000 Color: 4 standard Brittle Point: -76 F Ozone Resistance: No Cracks, ASTM D1149 UV Resistance: Very Good Secondary Seal Material PVC, ASTM D2000 Durometer 65 Shore A Product Description: SF is a gasketed exterior wall cover comprised of extruded aluminum frames, a Santoprene primary seal and a PVC secondary seal. This seal is designed to accommodate 50% movement. Use This Cover For: Exterior vertical applications where weather protection is critical. Frames designed to attach to most exterior finishes. 6" to 10" joint sizes with multi-directional movement. Factory welded transitions available. Four standard gasket colors. Performance Characteristics: Flush profile, colorable seals for exterior applications, expand and compress during movement while providing a weather tight seal. Standard Finishes: Gasket is available in Black, White, Gray and Greige. Custom colors available. Installation Guidelines: No blockouts required. The joint width should be consistent and smooth, respective to its nominal size. Apply butyl tape to aluminum frame and attach inside joint opening with C/S supplied fasteners. Apply sealant to aluminum frames and insert secondary seal and primary seal. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

175 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SF '' (152mm) 1.75'' (44mm) 9.00'' (229mm) 6.00'' (152mm) N/A N/A SF '' (178mm) 2.50'' (64mm) 10.50'' (267mm) 7.00'' (178mm) N/A N/A SF '' (203mm) 2.50'' (64mm) 12.00'' (305mm) 8.00'' (203mm) N/A N/A SF '' (229mm) 2.50'' (64mm) 13.50'' (343mm) 9.00'' (229mm) N/A N/A SF '' (254mm) 2.50'' (64mm) 15.00'' (381mm) 10.00'' (254mm) N/A N/A NOTE: Turnbar not required on 6" Model CONTINUOUS ALUMINUM FRAME JOINT CONTINUOUS PVC SECONDARY SEAL TURNBAR ASSEMBLY BUTYL CAULK FLEXIBLE PRIMARY SEAL 1/4" ALUMINUM CENTER MULLION SF-600/1000 CONTINUOUS PVC SECONDARY SEAL JOINT CONTINUOUS ALUMINUM FRAME TURNBAR ASSEMBLY BUTYL CAULK 1/4" ALUMINUM CENTER MULLION FLEXIBLE PRIMARY SEAL SF-600/1000 (Corner) 5.6

176 SF 1100/1600 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Santoprene Primary Seal Single Durometer: 70 Shore A, ASTM D2000 Color: 4 standard Brittle Point: -76 F Ozone Resistance: No Cracks, ASTM D1149 UV Resistance: Very Good Vapor Barrier Material Polyethylene, ASTM E Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Product Description: SF is a gasketed exterior wall cover comprised of extruded aluminum frames, a Santoprene primary seal and polyethylene vapor barrier. Multiple seals are used in combination to accommodate 50% movement. Seals are supported with pantograph support assemblies. Use This Cover For: Exterior vertical applications where weather protection is critical. Frames designed to attach to most exterior finishes. 11" to 16" joint sizes with multi-directional movement. (Contact factory for larger sizes) Factory welded transitions available. Four standard gasket colors. Performance Characteristics: Flush profile, colorable seals for exterior applications, expand and compress during movement, while providing a weather tight seal. Standard Finishes: Gasket is available in Black, White, Gray and Greige. Custom colors available. Installation Guidelines: No blockouts required. The joint width should be consistent and smooth, respective to its nominal size. Apply butyl tape to aluminum frame and attach inside joint opening with C/S supplied fasteners. Install pantograph support system behind frames. Apply sealant to aluminum frames and insert secondary seal and primary seal. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

177 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SF '' (279mm) 6.00'' (152mm) 16.50'' (419mm) 11.00'' (279mm) N/A N/A SF '' (305mm) 6.00'' (152mm) 18.00'' (457mm) 12.00'' (305mm) N/A N/A SF '' (330mm) 6.00'' (152mm) 19.50'' (495mm) 13.00'' (330mm) N/A N/A SF '' (356mm) 6.00'' (152mm) 21.00'' (533mm) 14.00'' (356mm) N/A N/A SF '' (381mm) 6.00'' (152mm) 22.50'' (572mm) 15.00'' (381mm) N/A N/A SF '' (406mm) 6.00'' (152mm) 24.00'' (610mm) 16.00'' (406mm) N/A N/A Contact factory for larger sizes. JOINT PANTOGRAPH LOAD SUPPORT LINKAGE, STAINLESS STEEL MEMBERS AND FASTENERS, AND ALUMINUM ATTACHMENT ANGLES POLYETHYLENE VAPOR BARRIER BUTYL CAULK CONTINUOUS ALUMINUM FRAME FLEXIBLE PRIMARY SEAL 1/4" ALUMINUM CENTER MULLION SF-1100/1600 JOINT WIDE POLYETHYLENE VAPOR BARRIER PANTOGRAPH LOAD SUPPORT LINKAGE, STAINLESS STEEL MEMBERS AND FASTENERS, AND ALUMINUM ATTACHMENT ANGLER BUTYL CAULK CONTINUOUS ALUMINUM FRAME 1/4" ALUMINUM CENTER MULLION FLEXIBLE PRIMARY SEAL SF-1100/1600 (Corner) 5.8

178 SC 300/400 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Santoprene Primary Seal Single Durometer: 70 Shore A, ASTM D2000 Color: 4 standard Brittle Point: -76 F Ozone Resistance: No Cracks, ASTM D1149 UV Resistance: Very Good Secondary Seal Material PVC ASTM D2000 Durometer 65 Shore A Product Description: SC is a gasketed exterior wall cover comprised of extruded aluminum frames, a Santoprene primary seal and a PVC secondary seal. Use This Cover For: Exterior vertical applications where weather protection is critical. Frames designed to attach to most exterior finishes. 3" to 4" joint sizes with multi-directional movement. Factory welded transitions available. Four standard gasket colors. Performance Characteristics: Serrated profile, colorable seals for exterior applications, expand and compress during movement while providing a weather tight seal. Standard Finishes: Gasket is available in Black, White, Gray and Greige. Custom colors available. Installation Guidelines: No blockouts required. The joint width should be consistent and smooth, respective to its nominal size. Apply butyl tape to aluminum frame and attach inside joint opening with C/S supplied fasteners. Apply sealant to aluminum frames and insert secondary seal and primary seal. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

179 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SC '' (76mm) 1.25'' (32mm) 6.00'' (152mm) 3.00'' (76mm) N/A N/A SC '' (102mm) 1.25'' (32mm) 8.00'' (203mm) 4.00'' (102mm) N/A N/A JOINT FLEXIBLE PRIMARY GASKET EXPOSED SURFACE SC-300/400 SC-300/400 (Corner) 5.10

180 SC 500/1000 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Santoprene Primary Seal Single Durometer: 70 Shore A, ASTM D2000 Color: 4 standard Brittle Point: -76 F Ozone Resistance: No Cracks, ASTM D1149 UV Resistance: Very Good Secondary Seal Material PVC ASTM D2000 Durometer 65 Shore A Product Description: SC is a gasketed exterior wall cover comprised of extruded aluminum frames, a Santoprene primary seal and a PVC secondary seal. Use This Cover For: Exterior vertical applications where weather protection is critical. Frames designed to attach to most exterior finishes. 5" to 10" joint sizes with multi-directional movement. Factory welded transitions available. Four standard gasket colors. Performance Characteristics: Serrated profile, colorable seals for exterior applications, expand and compress during movement while providing a weather tight seal. Standard Finishes: Gasket is available in Black, White, Gray and Greige. Custom colors available. Installation Guidelines: No blockouts required. The joint width should be consistent and smooth, respective to its nominal size. Apply butyl tape to aluminum frame and attach inside joint opening with C/S supplied fasteners. Apply sealant to aluminum frames and insert secondary seal and primary seal. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

181 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SC '' (127mm) 1.75'' (44mm) 10.00'' (254mm) 5.00'' (127mm) N/A N/A SC '' (152mm) 1.75'' (44mm) 12.00'' (305mm) 6.00'' (152mm) N/A N/A SC '' (178mm) 2.50'' (64mm) 14.00'' (356mm) 7.00'' (178mm) N/A N/A SC '' (203mm) 2.50'' (64mm) 16.00'' (406mm) 8.00'' (203mm) N/A N/A SC '' (229mm) 2.50'' (64mm) 18.00'' (457mm) 9.00'' (229mm) N/A N/A SC '' (254mm) 2.50'' (64mm) 20.00'' (508mm) 10.00'' (254mm) N/A N/A NOTE: Turnbar not required on 5" or 6" Models SC-500/1000 SC-500/1000 (Corner) 5.12

182 SC 1100/1600 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Santoprene Primary Seal Single Durometer: 70 Shore A, ASTM D2000 Color: 4 standard Brittle Point: -76 F Ozone Resistance: No Cracks, ASTM D1149 UV Resistance: Very Good Vapor Barrier Material Polyethylene, ASTM E Color Black. 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Product Description: SC is a gasketed exterior wall cover comprised of extruded aluminum frames, a Santoprene primary seal and polyethylene vapor barrier. Multiple seals are used in combination to accommodate 100% movement. Seals are supported with pantograph support assemblies. Use This Cover For: Exterior vertical applications where weather protection is critical. Frames designed to attach to most exterior finishes. 11" to 16" joint sizes with multi-directional movement. (Contact factory for larger sizes) Factory welded transitions available. Four standard gasket colors. Performance Characteristics: Serrated profile, colorable seals for exterior applications, expand and compress during movement while providing a weather tight seal. Standard Finishes: Gasket is available in Black, White, Gray and Greige. Custom colors available). Installation Guidelines: No blockouts required. The joint width should be consistent and smooth, respective to its nominal size. Apply butyl tape to aluminum frame and attach inside joint opening with C/S supplied fasteners. Install pantograph support system behind frames. Apply sealant to aluminum frames and insert secondary seal and primary seal. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

183 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SC '' (279mm) 6.00'' (152mm) 22.00'' (559mm) 11.00'' (279mm) N/A N/A SC '' (305mm) 6.00'' (152mm) 24.00'' (610mm) 12.00'' (305mm) N/A N/A SC '' (330mm) 6.00'' (152mm) 26.00'' (660mm) 13.00'' (330mm) N/A N/A SC '' (356mm) 6.00'' (152mm) 28.00'' (711mm) 14.00'' (356mm) N/A N/A SC '' (381mm) 6.00'' (152mm) 30.00'' (762mm) 15.00'' (381mm) N/A N/A SC '' (406mm) 6.00'' (152mm) 32.00'' (813mm) 16.00'' (406mm) N/A N/A For odd and larger size joints, call (800) or visit SC-1100/1600 SC-1100/1600 (Corner) 5.14

184 VF Series Technical Data: Durometer Hardness ASTM D2240, Shore A Flammability UL 94VO, Self Extinguishing Mildew Resistance Excellent Tensile Strength ASTM 3574, 21 psi min Product Description: This impregnated, compressible foam block is available in 12 standard colors and supplied in 5-0 lengths. Use This Cover For: Primary construction joints. Vertical or horizontal movement Expansion, control, and isolation joints. Retrofit joints. Pre-cast concrete walls Tilt-up walls. Exterior Panel Systems Masonry, granite, metal, EIFS, and curtain walls. Performance Characteristics: Once VF joint sealant is installed in the joint, the material expands, adapting to the width of the joint and the irregularities of the substrate provided. Such profile changes are not sudden or extreme. Standard Finishes: Standard Colors: Dow Corning 790. Custom colors available upon request. Installation Guidelines: Ensure that the joint is clean and will provide an appropriate surface for the joint sealant. Remove wrapping material and stick material to one side of joint opening. Material will self expand and seal to opposite side. For the complete technical data and installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

185 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT VF '' (25mm) 0.50'' (13mm) 1.50'' (38mm) 1.00'' (25mm) N/A N/A VF '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 2.00'' (51mm) N/A N/A VF '' (76mm) 1.50'' (38mm) 4.50'' (114mm) 3.00'' (76mm) N/A N/A VF '' (102mm) 2.00'' (51mm) 6.00'' (152mm) 4.00'' (102mm) N/A N/A VF '' (127mm) 2.50'' (64mm) 7.50'' (191mm) 5.00'' (127mm) N/A N/A VF '' (152mm) 3.00'' (76mm) 9.00'' (229mm) 6.00'' (152mm) N/A N/A VF '' (178mm) 3.50'' (89mm) 10.50'' (267mm) 7.00'' (178mm) N/A N/A VF '' (203mm) 4.00'' (102mm) 12.00'' (305mm) 8.00'' (203mm) N/A N/A JOINT "VF" EXPANSION JOINT EXPOSED SURFACE VF (Typ.) JOINT "VF" EXPANSION JOINT EXPOSED SURFACE VF (Typ. Corner) 5.16

186 AFW-X & AFWC-X Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Duroflex Gasket Single Durometer 65 Shore A, ASTM D2000 Color Gray Vapor Barrier Material Polyethylene, ASTM E Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Product Description: This metal wall cover is designed for exterior applications where low maintenance or tamper-resistant applications are desirable. Use This Cover For: Exterior applications Can be flush or surface mounted, depending on finish. Performance Characteristics: Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Cover can be painted to match wall finish. Standard Finishes: Clear anodize finish. Kynar paint available. Installation Guidelines: Install frame over the vapor barrier with the anchor bolts as supplied by C/S. The center plate is retained by the cover plates, which engage interlocking channels. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

187 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT AFW-100X 1.00'' (25mm) 0.25'' (6mm) 1.88'' (48mm) 5.00'' (127mm) 2.00'' (51mm) 0.63'' (16mm) AFW-200X 2.00'' (51mm) 0.38'' (10mm) 3.50'' (89mm) 7.75'' (197mm) 2.88'' (73mm) 0.63'' (16mm) AFW-300X 3.00'' (76mm) 0.00'' (0mm) 6.38'' (162mm) 10.75'' (273mm) 3.88'' (98mm) 0.63'' (16mm) AFW-400X 4.00'' (102mm) 1.00'' (25mm) 7.38'' (187mm) 11.75'' (298mm) 3.88'' (98mm) 0.63'' (16mm) AFW-500X 5.00'' (127mm) 2.25'' (57mm) 8.00'' (203mm) 12.75'' (324mm) 3.88'' (98mm) 0.63'' (16mm) AFW-600X 6.00'' (152mm) 3.25'' (83mm) 9.00'' (229mm) 13.75'' (349mm) 3.88'' (98mm) 0.63'' (16mm) AFW-700X 7.00'' (178mm) 3.00'' (76mm) 11.00'' (279mm) 17.00'' (432mm) 5.00'' (127mm) 0.63'' (16mm) AFW-800X 8.00'' (203mm) 4.00'' (102mm) 12.00'' (305mm) 18.00'' (457mm) 5.00'' (127mm) 0.63'' (16mm) AFWC-100X 1.00'' (25mm) 0.63'' (16mm) 1.44'' (37mm) 2.38'' (60mm) 2.00'' (51mm) 0.63'' (16mm) AFWC-200X 2.00'' (51mm) 1.19'' (30mm) 2.75'' (70mm) 4.25'' (108mm) 2.88'' (73mm) 0.63'' (16mm) AFWC-300X 3.00'' (76mm) 1.50'' (38mm) 4.69'' (119mm) 6.25'' (159mm) 3.88'' (98mm) 0.63'' (16mm) AFWC-400X 4.00'' (102mm) 2.50'' (64mm) 5.69'' (144mm) 7.25'' (184mm) 3.88'' (98mm) 0.63'' (16mm) AFWC-500X 5.00'' (127mm) 3.50'' (89mm) 6.50'' (165mm) 8.25'' (210mm) 3.88'' (98mm) 0.63'' (16mm) AFWC-600X 6.00'' (152mm) 4.50'' (114mm) 7.50'' (191mm) 9.25'' (235mm) 3.88'' (98mm) 0.63'' (16mm) AFWC-700X 7.00'' (178mm) 5.00'' (127mm) 9.00'' (229mm) 11.38'' (289mm) 5.00'' (127mm) 0.63'' (16mm) AFWC-800X 8.00'' (203mm) 6.00'' (152mm) 10.00'' (254mm) 12.38'' (314mm) 5.00'' (127mm) 0.63'' (16mm) JOINT 5/8" ALUMIMUM COVER PLATE ALUMINUM CENTER PLATE EXPOSED SURFACE AFW-X (Typ.) ALUMINUM ANCHOR FRAME FACTORY INSTALLED DUROFLEX GASKET JOINT ALUMINUM CENTER PLATE EXPOSED SURFACE CONTINUOUS EXTUDED ALUMINUM ANCHOR FRAME AFWC-X (Typ.) 5.18

188 ASM & ASMC Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T6) Duroflex Gasket Single Durometer 80 Shore A, ASTM D2000 Color - Gray Vapor Barrier Material Polyethylene, ASTM E Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Product Description: This surface mounted metal wall cover is designed for exterior applications where low maintenance or tamper proof applications are desirable. Use This Cover For: Applications where low maintenance is desirable or for tamperresistant applications. Performance Characteristics: Free-floating aluminum center plate spans joint and slides over the surface of the wall to allow movement when required. Cover can be painted to match wall finish. Standard Finishes: Clear anodize finish. Kynar painted top plates available. Installation Guidelines: Install anchor clips with the anchor bolts as supplied by C/S. The cover plate engages a J-Hook and locking channel for attachment. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

189 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ASM '' (25mm) 0.38'' (10mm) 3.00'' (76mm) 4.63'' (117mm) N/A N/A ASM '' (51mm) 0.38'' (10mm) 3.00'' (76mm) 4.63'' (117mm) N/A N/A ASM '' (76mm) 0.38'' (10mm) 6.00'' (152mm) 7.63'' (194mm) N/A N/A ASM '' (102mm) 0.38'' (10mm) 6.00'' (152mm) 7.63'' (194mm) N/A N/A ASMC '' (25mm) 0.50'' (13mm) 3.00'' (76mm) 3.38'' (86mm) N/A N/A ASMC '' (51mm) 0.50'' (13mm) 3.00'' (76mm) 3.38'' (86mm) N/A N/A ASMC '' (76mm) 0.50'' (13mm) 6.00'' (152mm) 6.38'' (162mm) N/A N/A ASMC '' (102mm) 0.50'' (13mm) 6.00'' (152mm) 6.38'' (162mm) N/A N/A VAPOR BARRIER 2" WIDE BACK CLIP DUROFLEX GASKET JOINT ALUMINUM COVER PLATE EXPOSED SURFACE ASM (TYP.) DUROFLEX GASKET JOINT VAPOR BARRIER 2" WIDE BACK CLIP 1 3/4" LUMINUM COVER PLATE EXPOSED SURFACE ASMC (TYP.) 5.20

190 ESW & ESC 400/1600 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Duroflex gasket Single Durometer 80 Shore A, ASTM D2000 Color Black Turnbar Material C1075 Blue Temper Spring Steel Hardness RC Finish A Coating (Corrosion protection) Vapor Barrier Material Polyethylene Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Product Description: ESW and ESC are aluminum exterior wall covers comprised of extruded aluminum components, spring steel turnbars, duroflex gaskets and polyethylene vapor barrier. Use This Cover For: Exterior wall applications for joints 4 and larger. Performance Characteristics: Durable design eliminates the need for maintenance and is more vandal resistant. Standard Finishes: Clear anodize finish. Kynar paint also available. Installation Guidelines: Attach the vapor barrier and frames to the substrate using mechanical fasteners. This model also uses a turnbar assembly. Splice plates and caulk are used to transition splices with weather tight seals. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

191 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ESW '' (102mm) 2.50'' (64mm) 6.00'' (152mm) 12.00'' (305mm) N/A N/A ESW '' (127mm) 2.50'' (64mm) 8.25'' (210mm) 13.50'' (343mm) N/A N/A ESW '' (152mm) 2.50'' (64mm) 10.00'' (254mm) 15.00'' (381mm) N/A N/A ESW '' (178mm) 2.50'' (64mm) 11.50'' (292mm) 16.50'' (419mm) N/A N/A ESW '' (203mm) 2.50'' (64mm) 13.00'' (330mm) 18.00'' (457mm) N/A N/A ESW '' (229mm) 2.50'' (64mm) 14.50'' (368mm) 19.50'' (495mm) N/A N/A ESW '' (254mm) 2.50'' (64mm) 16.00'' (406mm) 21.00'' (533mm) N/A N/A ESW '' (279mm) 2.50'' (64mm) 17.50'' (445mm) 22.50'' (572mm) N/A N/A ESW '' (305mm) 2.50'' (64mm) 19.00'' (483mm) 24.00'' (610mm) N/A N/A ESW '' (330mm) 2.50'' (64mm) 20.00'' (508mm) 25.50'' (648mm) N/A N/A ESW '' (356mm) 2.50'' (64mm) 22.00'' (559mm) 27.00'' (686mm) N/A N/A ESW '' (381mm) 2.50'' (64mm) 23.50'' (597mm) 28.50'' (724mm) N/A N/A ESW '' (406mm) 2.50'' (64mm) 25.00'' (635mm) 30.00'' (762mm) N/A N/A ESC '' (102mm) 3.25'' (83mm) 6.50'' (165mm) 8.00'' (203mm) N/A N/A ESC '' (127mm) 3.75'' (95mm) 7.50'' (191mm) 9.25'' (235mm) N/A N/A ESC '' (152mm) 4.25'' (108mm) 8.00'' (203mm) 10.50'' (267mm) N/A N/A ESC '' (178mm) 4.75'' (121mm) 9.25'' (235mm) 11.75'' (298mm) N/A N/A ESC '' (203mm) 5.25'' (133mm) 10.50'' (267mm) 13.00'' (330mm) N/A N/A ESC '' (229mm) 5.75'' (146mm) 11.75'' (298mm) 14.25'' (362mm) N/A N/A ESC '' (254mm) 6.25'' (159mm) 13.00'' (330mm) 15.50'' (394mm) N/A N/A ESC '' (279mm) 6.75'' (171mm) 14.25'' (362mm) 16.75'' (425mm) N/A N/A ESC '' (305mm) 7.25'' (184mm) 15.50'' (394mm) 18.00'' (457mm) N/A N/A ESC '' (330mm) 7.25'' (184mm) 16.75'' (425mm) 19.75'' (502mm) N/A N/A ESC '' (356mm) 7.75'' (197mm) 18.00'' (457mm) 20.50'' (521mm) N/A N/A ESC '' (381mm) 8.25'' (210mm) 19.25'' (489mm) 21.75'' (552mm) N/A N/A ESC '' (406mm) 8.75'' (222mm) 20.50'' (521mm) 23.00'' (584mm) N/A N/A Contact factory for larger sizes. JOINT ESW (Typ.) COVER PLATE ALUMINUM EXPOSED SURFACE JOINT ESC (Typ.) COVER PLATE ALUMINUM EXPOSED SURFACE 5.22

192 RJT-V & RJTW-V 100/200 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Duroflex Gasket Single Durometer 85 Shore A, ASTM D2000 Color Gray Vapor Barrier Material Polyethylene, ASTM E Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Turnbar Injection Molded Product Description: Aluminum wall covers comprised of extruded aluminum components, injection molded turnbar, duroflex gaskets and polyethylene vapor barrier. Use This Cover For: Exterior wall joint applications. Performance Characteristics: Available for movement of up to 50% of joint width. Available with custom factory made transitions to ensure watertight results. Standard Finishes: Mill finish. Powder coated or Kynar options available. Installation Guidelines: Install the frames with C/S supplied anchor bolts. The cover plate is retained by the injection molded turn bars, which engage in the frames. (Note: all butt splices and factory made transitions to be installed in accordance with manufacturer s recommended sequencing.) For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

193 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT RJT '' (25mm) 0.13'' (3mm) 2.63'' (67mm) 5.75'' (146mm) N/A N/A RJT '' (51mm) 0.13'' (3mm) 3.63'' (92mm) 5.75'' (146mm) N/A N/A RJTW '' (25mm) 0.13'' (3mm) 2.38'' (60mm) 3.88'' (98mm) N/A N/A RJTW '' (51mm) 0.13'' (3mm) 2.88'' (73mm) 3.88'' (98mm) N/A N/A JOINT VAPOR BARRIER ALUM. CURB DUROFLEX GASKET EXPOSED SURFACE ALUM. CENTER PLATE RJT-V (Typ.) JOINT ALUMINUM CENTER PLATE ALUMINUM CURB DUROFLEX GASKET EXPOSED SURFACE RJTW-V (Typ.) 5.24

194 SRJ-V & SRJW-V 300/1600 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Turnbar Material C1075 Blue Temper Spring Steel Hardness RC Finish A Coating (Corrosion protection) Duroflex Gasket Single Durometer 80 Shore A, ASTM D2000 Color Black. Vapor Barrier Material Polyethylene, ASTM E Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Product Description: Aluminum wall covers comprised of extruded aluminum components, spring steel turnbars, duroflex gaskets and polyethylene vapor barrier. Use This Cover For: Exterior wall joint applications. Performance Characteristics: Available for movement of up to 100% of joint width. Available with custom factory made transitions to ensure watertight results. Standard Finishes: Mill finish. Powder coated or Kynar options available. Installation Guidelines: Install the frames with the C/S supplied anchor bolts. Attach cover plate using self-centering turnbars in accordance with manufacturer s instructions. (Note: all butt splices and factory made transitions to be installed in accordance with manufacturer s recommended sequencing.) For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

195 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SRJ-300V 3.00'' (76mm) 1.00'' (25mm) 7.50'' (191mm) 11.00'' (279mm) N/A N/A SRJ-400V 4.00'' (102mm) 1.00'' (25mm) 7.50'' (191mm) 12.00'' (305mm) N/A N/A SRJ-500V 5.00'' (127mm) 1.00'' (25mm) 7.50'' (191mm) 13.50'' (343mm) N/A N/A SRJ-600V 6.00'' (152mm) 1.00'' (25mm) 11.75'' (298mm) 15.00'' (381mm) N/A N/A SRJ-700V 7.00'' (178mm) 1.00'' (25mm) 12.50'' (318mm) 16.50'' (419mm) N/A N/A SRJ-800V 8.00'' (203mm) 1.00'' (25mm) 12.50'' (318mm) 18.00'' (457mm) N/A N/A SRJ-900V 9.00'' (229mm) 1.00'' (25mm) 16.25'' (413mm) 19.50'' (495mm) N/A N/A SRJ-1000V 10.00'' (254mm) 1.00'' (25mm) 16.75'' (425mm) 21.00'' (533mm) N/A N/A SRJ-1100V 11.00'' (279mm) 1.00'' (25mm) 16.75'' (425mm) 22.50'' (572mm) N/A N/A SRJ-1200V 12.00'' (305mm) 1.00'' (25mm) 20.75'' (527mm) 24.00'' (610mm) N/A N/A SRJ-1300V 13.00'' (330mm) 1.00'' (25mm) 21.00'' (533mm) 25.50'' (648mm) N/A N/A SRJ-1400V 14.00'' (356mm) 1.00'' (25mm) 21.00'' (533mm) 27.00'' (686mm) N/A N/A SRJ-1500V 15.00'' (381mm) 1.00'' (25mm) 24.25'' (616mm) 28.50'' (724mm) N/A N/A SRJ-1600V 16.00'' (406mm) 1.00'' (25mm) 24.25'' (616mm) 30.00'' (762mm) N/A N/A SRJW-300V 3.00'' (76mm) 0.00'' (0mm) 5.25'' (133mm) 7.00'' (178mm) N/A N/A SRJW-400V 4.00'' (102mm) 0.00'' (0mm) 6.25'' (159mm) 8.00'' (203mm) N/A N/A SRJW-500V 5.00'' (127mm) 0.00'' (0mm) 7.50'' (191mm) 9.25'' (235mm) N/A N/A SRJW-600V 6.00'' (152mm) 0.00'' (0mm) 8.75'' (222mm) 10.50'' (267mm) N/A N/A SRJW-700V 7.00'' (178mm) 4.00'' (102mm) 9.75'' (248mm) 11.75'' (298mm) N/A N/A SRJW-800V 8.00'' (203mm) 4.50'' (114mm) 10.25'' (260mm) 13.00'' (330mm) N/A N/A SRJW-900V 9.00'' (229mm) 5.00'' (127mm) 12.50'' (318mm) 14.25'' (362mm) N/A N/A SRJW-1000V 10.00'' (254mm) 5.50'' (140mm) 13.25'' (337mm) 15.50'' (394mm) N/A N/A SRJW-1100V 11.00'' (279mm) 6.00'' (152mm) 13.75'' (349mm) 16.75'' (425mm) N/A N/A SRJW-1200V 12.00'' (305mm) 6.50'' (165mm) 16.25'' (413mm) 18.00'' (457mm) N/A N/A SRJW-1300V 13.00'' (330mm) 7.00'' (178mm) 17.06'' (433mm) 19.25'' (489mm) N/A N/A SRJW-1400V 14.00'' (356mm) 7.50'' (191mm) 17.50'' (445mm) 20.50'' (521mm) N/A N/A SRJW-1500V 15.00'' (381mm) 8.00'' (203mm) 19.50'' (495mm) 21.75'' (552mm) N/A N/A SRJW-1600V 16.00'' (406mm) 8.50'' (216mm) 20.00'' (508mm) 23.00'' (584mm) N/A N/A Contact factory for larger sizes. JOINT ALUMINUM FRAME CONTINUOUS MOISTURE SEAL NEOPRENE VAPOR BARRIER.090 FORMED ALUM COVER PLATE TURNBAR ASSEMBLY EXPOSED SURFACE SRJ-V (typ.) SRJW-V (typ.) 5.26

196 XLS & XLSC 800/3400 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Stainless Steel Continuous Hinge Product Description: XLS/XLSC are exterior wall joint covers comprised of extruded aluminum components and various mechanical hardware. Cover panel is a structural ladder frame assembly, which is to receive various field-applied finish materials (finishes not by C/S). Each unit is retained by (2 ea.) heavy-duty magnetic closures. Panel is designed to return to nominal closure position after an event via a counter weight. Use This Cover For: Exterior seismic wall applications where cover concealment is desired within the finishes. Lightweight finish applications up to 9/16" thick (supplied by others). Zero maintenance required after an earthquake. Where high wind loads are expected. Performance Characteristics: Flush exterior wall cover releases from wall on one side to provide full seismic movement. Cover returns to closed position after an event via counterweight system. Panels can be supplied in various heights to accommodate horizontal banding. Standard Finishes: Clear anodize finish Installation Guidelines: The blockouts must be flat, level and parallel. The base of the blockout must be flat (along the length of the joint) to within +/-1/16" [1.6mm] and level (across the joint) to within +/-1/16" [1.6mm]. The surface of the blockouts must be clean and free from any loose dust, dirt, debris and oils that would affect the installation of the covers. For the complete installation instructions, please go to To download detail, specs & photos visit For technical and design assistance call

197 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HINGE SIDE RETURN SIDE HEIGHT XLS '' (203mm) 4.00'' (102mm) 16.00'' (406mm) 17.31'' (440mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (229mm) 4.00'' (102mm) 18.00'' (457mm) 18.31'' (465mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (254mm) 4.00'' (102mm) 20.00'' (508mm) 19.31'' (491mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (279mm) 4.00'' (102mm) 22.00'' (559mm) 20.31'' (516mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (305mm) 4.00'' (102mm) 24.00'' (610mm) 21.31'' (541mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (330mm) 4.00'' (102mm) 26.00'' (660mm) 22.31'' (567mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (356mm) 4.00'' (102mm) 28.00'' (711mm) 23.31'' (592mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (381mm) 4.00'' (102mm) 30.00'' (762mm) 24.31'' (618mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (406mm) 4.00'' (102mm) 32.00'' (813mm) 25.31'' (643mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (432mm) 4.50'' (114mm) 34.00'' (864mm) 26.31'' (668mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (457mm) 4.50'' (114mm) 36.00'' (914mm) 27.31'' (694mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (483mm) 4.50'' (114mm) 38.00'' (965mm) 28.31'' (719mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (508mm) 4.50'' (114mm) 40.00'' (1016mm) 29.31'' (745mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (533mm) 4.50'' (114mm) 42.00'' (1067mm) 30.31'' (770mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (559mm) 4.50'' (114mm) 44.00'' (1118mm) 31.31'' (795mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (584mm) 4.50'' (114mm) 46.00'' (1168mm) 32.31'' (821mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (610mm) 4.50'' (114mm) 48.00'' (1219mm) 33.31'' (846mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (635mm) 4.50'' (114mm) 50.00'' (1270mm) 34.31'' (872mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (660mm) 4.50'' (114mm) 52.00'' (1321mm) 35.31'' (897mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (686mm) 4.50'' (114mm) 53.00'' (1346mm) 36.31'' (922mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (711mm) 4.50'' (114mm) 54.00'' (1372mm) 37.31'' (948mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (737mm) 4.50'' (114mm) 55.00'' (1397mm) 38.31'' (973mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (762mm) 4.50'' (114mm) 56.00'' (1422mm) 39.31'' (999mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (787mm) 4.50'' (114mm) 57.00'' (1448mm) 40.31'' (1024mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (813mm) 4.50'' (114mm) 58.00'' (1473mm) 41.31'' (1049mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (838mm) 4.50'' (114mm) 59.00'' (1499mm) 42.31'' (1075mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLS '' (864mm) 4.50'' (114mm) 60.00'' (1524mm) 43.31'' (1100mm) 4.31'' (110mm) 5.00'' (127mm) 2.00'' (51mm) XLSC '' (203mm) 4.00'' (102mm) 16.00'' (406mm) 13.00'' (330mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (229mm) 4.00'' (102mm) 18.00'' (457mm) 14.00'' (356mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (254mm) 4.00'' (102mm) 20.00'' (508mm) 15.00'' (381mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (279mm) 4.00'' (102mm) 22.00'' (559mm) 16.00'' (406mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (305mm) 4.00'' (102mm) 24.00'' (610mm) 17.00'' (432mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (330mm) 4.00'' (102mm) 26.00'' (660mm) 18.00'' (457mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (356mm) 4.00'' (102mm) 28.00'' (711mm) 19.00'' (483mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (381mm) 4.00'' (102mm) 30.00'' (762mm) 20.00'' (508mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (406mm) 4.00'' (102mm) 32.00'' (813mm) 21.00'' (533mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (432mm) 4.50'' (114mm) 34.00'' (864mm) 22.00'' (559mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (457mm) 4.50'' (114mm) 36.00'' (914mm) 23.00'' (584mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (483mm) 4.50'' (114mm) 38.00'' (965mm) 24.00'' (610mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (508mm) 4.50'' (114mm) 40.00'' (1016mm) 25.00'' (635mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (533mm) 4.50'' (114mm) 42.00'' (1067mm) 26.00'' (660mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (559mm) 4.50'' (114mm) 44.00'' (1118mm) 27.00'' (686mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (584mm) 4.50'' (114mm) 46.00'' (1168mm) 28.00'' (711mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (610mm) 4.50'' (114mm) 48.00'' (1219mm) 29.00'' (737mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (635mm) 4.50'' (114mm) 50.00'' (1270mm) 30.00'' (762mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (660mm) 4.50'' (114mm) 52.00'' (1321mm) 31.00'' (787mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (686mm) 4.50'' (114mm) 53.00'' (1346mm) 32.00'' (813mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (711mm) 4.50'' (114mm) 54.00'' (1372mm) 33.00'' (838mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (737mm) 4.50'' (114mm) 55.00'' (1397mm) 34.00'' (864mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (762mm) 4.50'' (114mm) 56.00'' (1422mm) 35.00'' (889mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (787mm) 4.50'' (114mm) 57.00'' (1448mm) 36.00'' (914mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (813mm) 4.50'' (114mm) 58.00'' (1473mm) 37.00'' (940mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (838mm) 4.50'' (114mm) 59.00'' (1499mm) 38.00'' (965mm) N/A 5.00'' (127mm) 2.00'' (51mm) XLSC '' (864mm) 4.50'' (114mm) 60.00'' (1524mm) 39.00'' (991mm) N/A 5.00'' (127mm) 2.00'' (51mm) Contact factory for larger sizes. 5.28

198 JOINT HEIGHT HEIGHT (HINGE SIDE) XLS COVER PLATE ASSEMBLY EXPOSED SURFACE (RETURN SIDE) XlS (Typ.) (RETURN SIDE) JOINT HEIGHT XLSC COVER PLATE ASSEMBLY EXPOSED SURFACE XlSC (Typ.) FiNiSH MATERiAlS NOT BY CONSTRuCTiON SPECiAlTiES, inc. 5.29

199 BRJ & BRJW Series Technical Data: Flanges (*=Optional flanges Galvanized is standard) Galvanized Steel - 26 Gage Stainless Steel* Aluminum* Copper* - 16 Oz.. Membrane (*=Optional material EPDM is standard) EPDM 60 Mil, Black Neoprene* 60 Mil, Black Support Foam K Factor Ambient Thickness Varies per Joint Size Product Description: BRJ and BRJW are flexible roof joint covers which utilize malleable membrane applied to support foam, and are secured with a factoryattached metal flange. Use This Cover For: Applications in built-up, flat or sloped roofs. Joint sizes from 2" to 36". Multi-directional movement requirements. Applications where exterior seals are used in walls and watertight transitions are critical. Performance Characteristics: The bellows material expands and contracts for multi-directional movement. Bellows roof cover system is capable of four-way movement. Optional waterstop is available. Available with factory fabricated transitions to ensure watertight results. Standard Finishes: Membrane Black, Flanges As fabricated. Installation Guidelines: Where intersections are required, install these first. Always start straight runs at roof edge or at intersections. Allow overhang at roof edge, equal to fascia depth. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

200 JOINT MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT BRJ '' (25mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJ '' (51mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJ '' (76mm) 0.00'' (0mm) 4.50'' (114mm) N/A N/A N/A BRJ '' (102mm) 0.00'' (0mm) 6.00'' (152mm) N/A N/A N/A BRJ '' (127mm) 0.00'' (0mm) 7.50'' (191mm) N/A N/A N/A BRJ '' (152mm) 0.00'' (0mm) 9.00'' (229mm) N/A N/A N/A BRJ '' (178mm) 0.00'' (0mm) 10.50'' (267mm) N/A N/A N/A BRJ '' (203mm) 0.00'' (0mm) 12.00'' (305mm) N/A N/A N/A BRJ '' (229mm) 0.00'' (0mm) 13.50'' (343mm) N/A N/A N/A BRJ '' (254mm) 0.00'' (0mm) 15.00'' (381mm) N/A N/A N/A BRJ '' (279mm) 0.00'' (0mm) 16.50'' (419mm) N/A N/A N/A BRJ '' (305mm) 0.00'' (0mm) 18.00'' (457mm) N/A N/A N/A BRJ '' (330mm) 0.00'' (0mm) 19.50'' (495mm) N/A N/A N/A BRJ '' (356mm) 0.00'' (0mm) 21.00'' (533mm) N/A N/A N/A BRJ '' (381mm) 0.00'' (0mm) 22.50'' (572mm) N/A N/A N/A BRJ '' (406mm) 0.00'' (0mm) 24.00'' (610mm) N/A N/A N/A BRJW '' (25mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJW '' (51mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJW '' (76mm) 0.00'' (0mm) 4.50'' (114mm) N/A N/A N/A BRJW '' (102mm) 0.00'' (0mm) 6.00'' (152mm) N/A N/A N/A BRJW '' (127mm) 0.00'' (0mm) 7.50'' (191mm) N/A N/A N/A BRJW '' (152mm) 0.00'' (0mm) 9.00'' (229mm) N/A N/A N/A BRJW '' (178mm) 0.00'' (0mm) 10.50'' (267mm) N/A N/A N/A BRJW '' (203mm) 0.00'' (0mm) 12.00'' (305mm) N/A N/A N/A BRJW '' (229mm) 0.00'' (0mm) 13.50'' (343mm) N/A N/A N/A BRJW '' (254mm) 0.00'' (0mm) 15.00'' (381mm) N/A N/A N/A BRJW '' (279mm) 0.00'' (0mm) 16.50'' (419mm) N/A N/A N/A BRJW '' (305mm) 0.00'' (0mm) 18.00'' (457mm) N/A N/A N/A BRJW '' (330mm) 0.00'' (0mm) 19.50'' (495mm) N/A N/A N/A BRJW '' (356mm) 0.00'' (0mm) 21.00'' (533mm) N/A N/A N/A BRJW '' (381mm) 0.00'' (0mm) 22.50'' (572mm) N/A N/A N/A BRJW '' (406mm) 0.00'' (0mm) 24.00'' (610mm) N/A N/A N/A Contact factory for larger sizes. EPDM BELLOWS EPDM BELLOWS 4" METAL RETAINER MIN. 15 MIN. 15 JOINT BRJ (typ.) BRJW (typ.) 5.32

201 BRJ-CF & BRJW-CF 200/1600 Series Technical Data: Flanges (*=Optional flanges Galvanized is standard) Galvanized Steel - 26 Gage Stainless Steel* Aluminum* Copper* - 16 Oz.. Membrane (*=Optional material EPDM is standard) EPDM 60 Mil, Black Neoprene* 60 Mil, Black Support Foam K Factor Ambient Thickness Varies per Joint Size Product Description: BRJ and BRJW are flexible roof joint covers which utilize malleable membrane applied to support foam, and are secured with a factoryattached metal flange. Use This Cover For: Applications in built-up, flat or sloped roofs. Joint sizes from 2" to 36" Multi-directional movement requirements. Applications where exterior seals are used in walls and watertight transitions are critical. Performance Characteristics: The bellows material expands and contracts for multi-directional movement. Bellows roof cover system is capable of four-way movement. Optional waterstop is available. Available with factory fabricated transitions to ensure watertight results. Standard Finishes: Membrane Black, Flanges As fabricated. Installation Guidelines: Where intersections are required, install these first. Always start straight runs at roof edge or at intersections. Allow overhang at roof edge, equal to fascia depth. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

202 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT BRJ-100CF 1.00'' (25mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJ-200CF 2.00'' (51mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJ-300CF 3.00'' (76mm) 0.00'' (0mm) 4.50'' (114mm) N/A N/A N/A BRJ-400CF 4.00'' (102mm) 0.00'' (0mm) 6.00'' (152mm) N/A N/A N/A BRJ-500CF 5.00'' (127mm) 0.00'' (0mm) 7.50'' (191mm) N/A N/A N/A BRJ-600CF 6.00'' (152mm) 0.00'' (0mm) 9.00'' (229mm) N/A N/A N/A BRJ-700CF 7.00'' (178mm) 0.00'' (0mm) 10.50'' (267mm) N/A N/A N/A BRJ-800CF 8.00'' (203mm) 0.00'' (0mm) 12.00'' (305mm) N/A N/A N/A BRJ-900CF 9.00'' (229mm) 0.00'' (0mm) 13.50'' (343mm) N/A N/A N/A BRJ-1000CF 10.00'' (254mm) 0.00'' (0mm) 15.00'' (381mm) N/A N/A N/A BRJ-1100CF 11.00'' (279mm) 0.00'' (0mm) 16.50'' (419mm) N/A N/A N/A BRJ-1200CF 12.00'' (305mm) 0.00'' (0mm) 18.00'' (457mm) N/A N/A N/A BRJ-1300CF 13.00'' (330mm) 0.00'' (0mm) 19.50'' (495mm) N/A N/A N/A BRJ-1400CF 14.00'' (356mm) 0.00'' (0mm) 21.00'' (533mm) N/A N/A N/A BRJ-1500CF 15.00'' (381mm) 0.00'' (0mm) 22.50'' (572mm) N/A N/A N/A BRJ-1600CF 16.00'' (406mm) 0.00'' (0mm) 24.00'' (610mm) N/A N/A N/A BRJW-100CF 1.00'' (25mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJW-200CF 2.00'' (51mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJW-300CF 3.00'' (76mm) 0.00'' (0mm) 4.50'' (114mm) N/A N/A N/A BRJW-400CF 4.00'' (102mm) 0.00'' (0mm) 6.00'' (152mm) N/A N/A N/A BRJW-500CF 5.00'' (127mm) 0.00'' (0mm) 7.50'' (191mm) N/A N/A N/A BRJW-600CF 6.00'' (152mm) 0.00'' (0mm) 9.00'' (229mm) N/A N/A N/A BRJW-700CF 7.00'' (178mm) 0.00'' (0mm) 10.50'' (267mm) N/A N/A N/A BRJW-800CF 8.00'' (203mm) 0.00'' (0mm) 12.00'' (305mm) N/A N/A N/A BRJW-900CF 9.00'' (229mm) 0.00'' (0mm) 13.50'' (343mm) N/A N/A N/A BRJW-1000CF 10.00'' (254mm) 0.00'' (0mm) 15.00'' (381mm) N/A N/A N/A BRJW-1100CF 11.00'' (279mm) 0.00'' (0mm) 16.50'' (419mm) N/A N/A N/A BRJW-1200CF 12.00'' (305mm) 0.00'' (0mm) 18.00'' (457mm) N/A N/A N/A BRJW-1300CF 13.00'' (330mm) 0.00'' (0mm) 19.50'' (495mm) N/A N/A N/A BRJW-1400CF 14.00'' (356mm) 0.00'' (0mm) 21.00'' (533mm) N/A N/A N/A BRJW-1500CF 15.00'' (381mm) 0.00'' (0mm) 22.50'' (572mm) N/A N/A N/A BRJW-1600CF 16.00'' (406mm) 0.00'' (0mm) 24.00'' (610mm) N/A N/A N/A Contact factory for larger sizes. WALL (BY OTHERS) REGLET AND FLASHING (BY OTHERS) EPDM BELLOWS CLOSED CELL FOAM 2" JOINT EPDM BELLOWS CLOSED CELL FOAM 2" X 2", 26 GA GALVANIZED METAL RETAINER GALV. NAIL WITH RUBBER GROMMET 2" X 2", 26 GA GALVANIZED METAL RETAINER GALV. NAIL WITH RUBBER GROMMET 2" JOINT BRJ-CF (typ.) BRJW-CF (typ.) 5.34

203 BRJ-WC & BRJW-WC 200/1600 Series Technical Data: Flanges (*=Optional flanges Galvanized is standard) Galvanized Steel - 26 Gage Stainless Steel* Aluminum* Copper* - 16 Oz. Membrane (*=Optional material EPDM is standard) EPDM 60 Mil, Black Neoprene* 60 Mil, Black Support Foam K Factor Ambient Thickness Varies per Joint Size Product Description: BRJ and BRJW are flexible roof joint covers which utilize malleable membrane applied to support foam, and are secured with a factoryattached metal flange. Use This Cover For: Applications in built-up, flat or sloped roofs. Joint sizes from 2" to 36. Multi-directional movement requirements. Applications where exterior seals are used in walls and watertight transitions are critical. Performance Characteristics: The bellows material expands and contracts for multi-directional movement. Bellows roof cover system is capable of four-way movement. Optional waterstop is available. Available with factory fabricated transitions to ensure watertight results. Standard Finishes: Membrane Black, Flanges As fabricated. Installation Guidelines: Where intersections are required, install these first. Always start straight runs at roof edge or at intersections. Allow overhang at roof edge, equal to fascia depth. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

204 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT BRJ-100 WC 1.00'' (25mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJ-200 WC 2.00'' (51mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJ-300 WC 3.00'' (76mm) 0.00'' (0mm) 4.50'' (114mm) N/A N/A N/A BRJ-400 WC 4.00'' (102mm) 0.00'' (0mm) 6.00'' (152mm) N/A N/A N/A BRJ-500 WC 5.00'' (127mm) 0.00'' (0mm) 7.50'' (191mm) N/A N/A N/A BRJ-600 WC 6.00'' (152mm) 0.00'' (0mm) 9.00'' (229mm) N/A N/A N/A BRJ-700 WC 7.00'' (178mm) 0.00'' (0mm) 10.50'' (267mm) N/A N/A N/A BRJ-800 WC 8.00'' (203mm) 0.00'' (0mm) 12.00'' (305mm) N/A N/A N/A BRJ-900 WC 9.00'' (229mm) 0.00'' (0mm) 13.50'' (343mm) N/A N/A N/A BRJ-1000 WC 10.00'' (254mm) 0.00'' (0mm) 15.00'' (381mm) N/A N/A N/A BRJ-1100 WC 11.00'' (279mm) 0.00'' (0mm) 16.50'' (419mm) N/A N/A N/A BRJ-1200 WC 12.00'' (305mm) 0.00'' (0mm) 18.00'' (457mm) N/A N/A N/A BRJ-1300 WC 13.00'' (330mm) 0.00'' (0mm) 19.50'' (495mm) N/A N/A N/A BRJ-1400 WC 14.00'' (356mm) 0.00'' (0mm) 21.00'' (533mm) N/A N/A N/A BRJ-1500 WC 15.00'' (381mm) 0.00'' (0mm) 22.50'' (572mm) N/A N/A N/A BRJ-1600 WC 16.00'' (406mm) 0.00'' (0mm) 24.00'' (610mm) N/A N/A N/A BRJW-100 WC 1.00'' (25mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJW-200 WC 2.00'' (51mm) 0.00'' (0mm) 3.00'' (76mm) N/A N/A N/A BRJW-300 WC 3.00'' (76mm) 0.00'' (0mm) 4.50'' (114mm) N/A N/A N/A BRJW-400 WC 4.00'' (102mm) 0.00'' (0mm) 6.00'' (152mm) N/A N/A N/A BRJW-500 WC 5.00'' (127mm) 0.00'' (0mm) 7.50'' (191mm) N/A N/A N/A BRJW-600 WC 6.00'' (152mm) 0.00'' (0mm) 9.00'' (229mm) N/A N/A N/A BRJW-700 WC 7.00'' (178mm) 0.00'' (0mm) 10.50'' (267mm) N/A N/A N/A BRJW-800 WC 8.00'' (203mm) 0.00'' (0mm) 12.00'' (305mm) N/A N/A N/A BRJW-900 WC 9.00'' (229mm) 0.00'' (0mm) 13.50'' (343mm) N/A N/A N/A BRJW-1000 WC 10.00'' (254mm) 0.00'' (0mm) 15.00'' (381mm) N/A N/A N/A BRJW-1100 WC 11.00'' (279mm) 0.00'' (0mm) 16.50'' (419mm) N/A N/A N/A BRJW-1200 WC 12.00'' (305mm) 0.00'' (0mm) 18.00'' (457mm) N/A N/A N/A BRJW-1300 WC 13.00'' (330mm) 0.00'' (0mm) 19.50'' (495mm) N/A N/A N/A BRJW-1400 WC 14.00'' (356mm) 0.00'' (0mm) 21.00'' (533mm) N/A N/A N/A BRJW-1500 WC 15.00'' (381mm) 0.00'' (0mm) 22.50'' (572mm) N/A N/A N/A BRJW-1600 WC 16.00'' (406mm) 0.00'' (0mm) 24.00'' (610mm) N/A N/A N/A Contact factory for larger sizes. REGLET AND FLASHING (BY OTHERS) ALUMINUM ANCHOR BAR EPDM BELLOWS ALUMINUM ANCHOR BAR EPDM COVER BONDED TO BELLOWS CLOSED CELL FOAM 2" WIDE 26 GA GALVANIZED METAL RETAINER WRAPPED IN NEOPRENE 60MIL EPDM BELLOWS 1 1/2" 1 1/2" ADVISE PARAPET JOINT ADVISE PARAPET CLOSED CELL FOAM EPDM COVER BONDED TO BELLOWS GALVANIZED METAL RETAINER WRAPPED IN NEOPRENE ALUMINUM ANCHOR BAR 1 1/2" ADVISE PARAPET JOINT BRJ-WC (typ.) BRJW-WC (typ.) 5.36

205 RJT & RJTW 100/200 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Duroflex Gasket Single Durometer 85 Shore A, ASTM D2000 Color Gray Vapor Barrier Material Polyethylene, ASTM E Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Turnbar Injection Molded Product Description: Aluminum roof covers comprised of extruded aluminum components, injection molded turnbar, duroflex gaskets and polyethylene vapor barrier. Use This Cover For: Roof joint applications where occasional access is expected. Applications where exterior seals are used in walls and watertight transitions are critical. Performance Characteristics: Available for movement of up to 50% of joint width in all horizontal directions. Available with custom factory made transitions to ensure watertight results. Standard Finishes: Mill finish. Powder coat & Kynar options available. Installation Guidelines: Finish roof membrane up onto wooden curbs. Apply vapor barrier over roof membrane using mastic adhesive supplied. Adjust angle on aluminum side frame to suit angle of curb (up to 90 ) and fasten through membrane and vapor barrier with fasteners provided. The cover plate is retained by the injection molded turnbars, which engage in the frames. (Note: all butt splices and factory made transitions to be installed in accordance with manufacturer s recommended sequencing.) For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

206 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT RJT '' (25mm) 0.13'' (3mm) 2.63'' (67mm) 5.75'' (146mm) N/A N/A RJT '' (51mm) 0.13'' (3mm) 3.63'' (92mm) 5.75'' (146mm) N/A N/A RJTW '' (25mm) 0.13'' (3mm) 2.38'' (60mm) 3.88'' (98mm) N/A N/A RJTW '' (51mm) 0.13'' (3mm) 2.88'' (73mm) 3.88'' (98mm) N/A N/A EXPOSED SURFACE ALUMINUM COVER PLATE ALUM. CURB JOINT RJT (typ.) EXPOSED SURFACE ALUMINUM COVER PLATE ALUMINUM CURB JOINT RJTW (typ.) 5.38

207 SRJ & SRJW 300/1600 Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003-H14, 5005-H34, ASTM B209 Turnbar Material C1075 Blue Temper Spring Steel Hardness - RC Finish - A Coating (Corrosion Protection). Duroflex Gasket Duromete 80 Shore A, ASTM D2000 Color Black Vapor Barrier Material Polyethelene, ASTM E Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Product Description: Aluminum roof covers comprised of extruded aluminum components, spring steel turnbars, duroflex gaskets and polyethylene vapor barrier. Use This Cover For: Roof joint applications where occasional access is expected. Applications where exterior seals are used in walls and watertight transitions are critical. Performance Characteristics: Available for movement of up to 100% of joint width in all horizontal directions. Available with custom factory made transitions to ensure watertight results. Standard Finishes: Mill finish. Powder coated and Kynar options available. Installation Guidelines: Finish roof membrane up onto wooden curbs. Apply vapor barrier over roof membrane using mastic adhesive supplied. Adjust angle on aluminum side frame to suit angle of curb (up to 90 ) and fasten through membrane and vapor barrier with fasteners provided. Attach cover plate using self-centering turnbars in accordance with manufacturer s instructions. (Note: all butt splices and factory made transitions to be installed in accordance with manufacturer s recommended sequencing.) For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

208 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT SRJ '' (76mm) 1.00'' (25mm) 7.50'' (191mm) 11.00'' (279mm) N/A N/A SRJ '' (102mm) 1.00'' (25mm) 7.50'' (191mm) 12.00'' (305mm) N/A N/A SRJ '' (127mm) 1.00'' (25mm) 7.50'' (191mm) 13.50'' (343mm) N/A N/A SRJ '' (152mm) 1.00'' (25mm) 11.75'' (298mm) 15.00'' (381mm) N/A N/A SRJ '' (178mm) 1.00'' (25mm) 12.50'' (318mm) 16.50'' (419mm) N/A N/A SRJ '' (203mm) 1.00'' (25mm) 12.50'' (318mm) 18.00'' (457mm) N/A N/A SRJ '' (229mm) 1.00'' (25mm) 16.25'' (413mm) 19.50'' (495mm) N/A N/A SRJ '' (254mm) 1.00'' (25mm) 16.75'' (425mm) 21.00'' (533mm) N/A N/A SRJ '' (279mm) 1.00'' (25mm) 16.75'' (425mm) 22.50'' (572mm) N/A N/A SRJ '' (305mm) 1.00'' (25mm) 20.75'' (527mm) 24.00'' (610mm) N/A N/A SRJ '' (330mm) 1.00'' (25mm) 21.00'' (533mm) 25.50'' (648mm) N/A N/A SRJ '' (356mm) 1.00'' (25mm) 21.00'' (533mm) 27.00'' (686mm) N/A N/A SRJ '' (381mm) 1.00'' (25mm) 24.25'' (616mm) 28.50'' (724mm) N/A N/A SRJ '' (406mm) 1.00'' (25mm) 24.25'' (616mm) 30.00'' (762mm) N/A N/A SRJW '' (76mm) 0.00'' (0mm) 5.25'' (133mm) 7.00'' (178mm) N/A N/A SRJW '' (102mm) 0.00'' (0mm) 6.25'' (159mm) 8.00'' (203mm) N/A N/A SRJW '' (127mm) 0.00'' (0mm) 7.50'' (191mm) 9.25'' (235mm) N/A N/A SRJW '' (152mm) 0.00'' (0mm) 8.75'' (222mm) 10.50'' (267mm) N/A N/A SRJW '' (178mm) 4.00'' (102mm) 9.75'' (248mm) 11.75'' (298mm) N/A N/A SRJW '' (203mm) 4.50'' (114mm) 10.25'' (260mm) 13.00'' (330mm) N/A N/A SRJW '' (229mm) 5.00'' (127mm) 12.50'' (318mm) 14.25'' (362mm) N/A N/A SRJW '' (254mm) 5.50'' (140mm) 13.25'' (337mm) 15.50'' (394mm) N/A N/A SRJW '' (279mm) 6.00'' (152mm) 13.75'' (349mm) 16.75'' (425mm) N/A N/A SRJW '' (305mm) 6.50'' (165mm) 16.25'' (413mm) 18.00'' (457mm) N/A N/A SRJW '' (330mm) 7.00'' (178mm) 17.06'' (433mm) 19.25'' (489mm) N/A N/A SRJW '' (356mm) 7.50'' (191mm) 17.50'' (445mm) 20.50'' (521mm) N/A N/A SRJW '' (381mm) 8.00'' (203mm) 19.50'' (495mm) 21.75'' (552mm) N/A N/A SRJW '' (406mm) 8.50'' (216mm) 20.00'' (508mm) 23.00'' (584mm) N/A N/A Contact factory for larger sizes. EXPOSED SURFACE ALUMINUM COVER EXPOSED SURFACE ALUMINUM COVER JOINT JOINT SRJ (typ.) SRJW (typ.) 5.40

209 MARR & MARC Series Product Highlights OSHPD approved design Complies with ASTM E1399 Virtually any joint size/movement capability can be accommodated. Performance Characteristics: This system allows full movement between base isolated and fixed structures. It is perfect for areas where up to 100% movement in four directions is required. Because base isolated structures are free to move in any horizontal direction, they create distinct challenges for the design of the seismic joint covers. The C/S solution for base isolated structures is an integrated assembly approach which provides full movement of up to 100% in any direction. Installation Guidelines: This cover system is designed on a job to job basis. Contact the factory for design and installation guidelines catered to your project. To download detail, specs & photos visit For technical and design assistance call

210 NOTE: This product is factory customized to fit your project needs. Please call the factory to discuss movement data and requirements. EXPOSED SURFACE ALUMINUM CLOSURE ANGLE HAT CHANNEL STANDING SEAM ROOF COVER ROOF WELDMENT LATERAL SLIDER ASSEMBLY UPLIFT ASSEMBLY LATERAL SLIDE FRAME ASSEMBLY ALUMINUM ROOF FRAME JOINT REINFORCED POLYETHYLENE VAPOR BARRIER MARR (typ.) EXPOSED SURFACE STANDING SEAM ROOF COVER HAT CHANNEL ALUMINUM CLOSURE ANGLE ROOF WELDMENT LATERAL SLIDER ASSEMBLY UPLIFT ASSEMBLY LATERAL SLIDE FRAME ASSEMBLY ROOF MOUNTING ANGLE JOINT REINFORCED POLYETHYLENE VAPOR BARRIER MARC (typ.) 5.42

211 Exterior Joint Transitions - SF Transitions SECONDARY SEAL TO FINISH WITHIN BASE CLOSURE SECONDARY SEAL TO FINISH WITHIN BASE CLOSURE BASE CLOSURE AT CHANGE TO SMALLER JOINT (FACTORY SUPPLIES FLAT MATERIAL AND THE CLOSURE IS FIELD FORMED) PRIMARY SEAL OR LARGER JOINT TO FINISH 1/8" SHORT OF BASE CLOSURE TO ALLOW FOR DRAINAGE. PRIMARY SEAL OF SMALLER JOINT TO FINISH TIGHT TO BOTTOM OF CLOSURE BASE CLOSURE (BC) AT CHANGE IN JOINT SIZE BASE CLOSURE (FACTORY SUPPLIES FLAT MATERIAL AND THE CLOSURE IS FIELD FORMED) BASE CLOSURE (BC) PRIMARY SEAL TO FINISH 1/8" SHORT OF BASE CLOSURE TO ALLOW FOR DRAINAGE FIELD SPLICE FACTORY FABRICATED BELLOWS MITER FIELD SPLICE FACTORY FABRICATED MITER SF INSIDE CORNER MITER SF OUTSIDE CORNER MITER 5.43

212 Exterior Joint Transitions - Bellows Transitions SF SEAL TO BE MOUNTED INSIDE VERTICAL BELLOW OF CORNER MITER FACTORY FABRICATED BELLOWS MITER REGLET AND COUNTER FLASHING (BY OTHERS) FIELD APPLIED SPLICE COVER FACTORY FABRICATED BELLOWS MITER FIELD APPLIED SPLICE COVER BRJW ROOF COVER BRJ 90 MITER 3-WAY ROOF TO WALL TRANSITION AT OFFSET JOINT FACTORY FABRICATED "CROSS OVER" MITER FACTORY FABRICATED "TEE" MITER FIELD APPLIED SPLICE COVER FIELD APPLIED SPLICE COVER BRJ CROSS OVER MITER BRJ TEE MITER 5.44

213 Exterior Joint Transitions - Bellows Transitions FACTORY FABRICATED MITER PARAPET FIELD APPLIED SPLICE COVER NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. FACTORY FABRICATED BELLOWS MITER SF SEAL TO BE MOUNTED INSIDE VERTICAL BELLOW OF CORNER MITER FIELD TRIM SEAL TO FIT AROUND PROFILE OF ROOF BELLOWS FIELD APPLIED SPLICE COVER FACTORY FABRICATED BELLOWS MITER SF WALL COVER BASE CLOSURE (FACTORY SUPPLIES FLAT MATERIAL AND THE CLOSURE IS FIELD FORMED) BRJ TO SF TRANSITION AT ROOF EDGE BRJ TO SF TRANSITION AT PARAPET REGLET AND COUNTER FLASHING (BY OTHERS) FACTORY FABRICATED BELLOWS MITER FIELD APPLIED SPLICE COVER REGLET AND COUNTER FLASHING (BY OTHERS) FIELD APPLIED SPLICE COVER FACTORY FABRICATED BELLOWS MITER BRJW 90 INSIDE CORNER MITER BRJW 90 OUTSIDE CORNER MITER 5.45

214 Exterior Joint Transitions - Bellows Transitions REGLET AND COUNTER FLASHING (BY OTHERS) FIELD APPLIED SPLICE COVER FACTORY FABRICATED MITER PARAPET FACTORY FABRICATED BELLOWS MITER NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. SF SEAL TO BE MOUNTED INSIDE VERTICAL BELLOW OF CORNER MITER FIELD TRIM SEAL TO FIT AROUND PROFILE OF ROOF BELLOWS REGLET AND COUNTER FLASHING (BY OTHERS) FIELD APPLIED SPLICE COVER BRJW ROOF COVER FIELD APPLIED SPLICE COVER BRJW ROOF COVER FACTORY FABRICATED BELLOWS MITER BRJ ROOF COVER BRJW TO BRJ TRANSITION BRJW TO SF TRANSITION AT PARAPET FIELD APPLIED SPLICE COVER REGLET AND COUNTER FLASHING (BY OTHERS) SF SEAL TO BE MOUNTED INSIDE VERTICAL BELLOW OF CORNER MITER REGLET AND COUNTER FLASHING (BY OTHERS) FACTORY FABRICATED BELLOWS MITER FACTORY FABRICATED BELLOWS MITER SF WALL COVER BASE CLOSURE (FACTORY SUPPLIES FLAT MATERIAL AND THE CLOSURE IS FIELD FORMED) BRJW ROOF COVER FIELD APPLIED SPLICE COVER BRJW TO SF TRANSITION AT ROOF EDGE ROOF TO WALL TRANSITION AT OFFSET JOINT 5.46

215 Exterior Joint Transitions - Metal Transitions FACTORY WELDED MITER FACTORY WELDED "TEE" MITER REGLET AND COUNTER FLASHING (BY OTHERS) ALUMINUM SPLICE PLATE PARAPET FORMED ALUMINUM SPLICE COVERS 6" 1 1/2" ESC WALL COVER FORMED ALUMINUM ROOF END CAP AT TRANSITION TO WALL COVER BRJ TEE MITER SRJW ROOF TO WALL COVER NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. SRJW TO ESC TRANSITION AT PARAPET FACTORY WELDED "CROSS OVER" MITER FACTORY MITERED AND WELDED CORNER FORMED ALUMINUM SPLICE COVERS FORMED ALUMINUM SPLICE COVERS SRJ ROOF TO ROOF COVER SRJ 90 MITER SRJ CROSS OVER MITER 5.47

216 Exterior Joint Transitions - Metal Transitions FACTORY WELDED MITER PARAPET NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. SEAL BETWEEN ROOF FRAME AND BACK SIDE OF END CAP WITH SILICONE SEALANT. (SEALANT BY OTHERS) 4" 6" 6" SRJ ROOF TO ROOF COVER FORMED ALUMINUM ROOF END CAP SET IN SEALANT AND SCREWED TO ROOF COVER. (SEALANT BY OTHERS) ALUMINUM SPLICE PLATE 1 1/2" ESW WALL COVER FORMED ALUMINUM ROOF END CAP AT TRANSITION TO WALL COVER NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. 6" SRJ ROOF TO ROOF COVER FORMED ALUMINUM WALL END CAP SET IN SEALANT. (SEALANT BY OTHERS) SRJ TO ESW TRANSITION AT PARAPET SRJ TO ESW TRANSITION AT ROOF EDGE FACTORY FABRICATED MITER COPING SLIP JOINT (BY OTHERS) PARAPET NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. SF WALL COVER SEAL BETWEEN ROOF FRAME AND BACK SIDE OF END CAP WITH SILICONE SEALANT. (SEALANT BY OTHERS) 1 1/2" FORMED ALUMINUM ROOF END CAP AT TRANSITION TO WALL COVER 6" SRJ ROOF TO ROOF COVER BASE CLOSURE (FACTORY SUPPLIES FLAT MATERIAL AND THE CLOSURE IS FIELD FORMED) 6" SRJ ROOF TO ROOF COVER 6" FORMED ALUMINUM ROOF END CAP AT TRANSITION TO WALL COVER SF WALL COVER NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. SRJ TO SF TRANSITION AT PARAPET SRJ TO SF TRANSITION AT ROOF EDGE 5.48

217 Exterior Joint Transitions - Metal Transitions REGLET AND COUNTER FLASHING (BY OTHERS) FACTORY MITERED AND WELDED CORNER REGLET AND COUNTER FLASHING (BY OTHERS) SRJW ROOF TO WALL COVER FORMED ALUMINUM SPLICE COVERS SET IN SEALANT AND SCREWED TO ROOF COVER ON ONE SIDE ONLY (SEALANT BY OTHERS) SRJW 90 INSIDE CORNER MITER SRJW ROOF TO WALL COVER FORMED ALUMINUM SPLICE COVERS FACTORY MITERED AND WELDED CORNER SRJW 90 OUTSIDE CORNER MITER REGLET AND COUNTER FLASHING (BY OTHERS) SEAL BETWEEN ROOF FRAME AND BACK SIDE OF END CAP WITH SILICONE SEALANT. (SEALANT BY OTHERS) FACTORY FABRICATED MITER FORMED ALUMINUM ROOF END CAP SET IN SEALANT AND SCREWED TO ROOF COVER. (SEALANT BY OTHERS) 1 1/2" 6" 6" SRJW ROOF TO WALL COVER NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. FORMED ALUMINUM WALL END CAP SET IN SEALANT. (SEALANT BY OTHERS) REGLET AND COUNTER FLASHING (BY OTHERS) 6" PARAPET SF WALL COVER 1 1/2" BASE CLOSURE (FACTORY SUPPLIES FLAT MATERIAL AND THE CLOSURE IS FIELD FORMED) FORMED ALUMINUM ROOF END CAP SET IN SEALANT AND SCREWED TO ROOF COVER. (SEALANT BY OTHERS) NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. SRJW TO ESW TRANSITION AT ROOF EDGE SRJW ROOF TO WALL COVER SRJW TO SF TRANSITION AT PARAPET 5.49

218 Exterior Joint Transitions - Metal Transitions REGLET AND COUNTER FLASHING (BY OTHERS) REGLET AND COUNTER FLASHING (BY OTHERS) SEAL BETWEEN ROOF FRAME AND BACK SIDE OF END CAP WITH SILICONE SEALANT. (SEALANT BY OTHERS) 1 1/2" SF WALL COVER 6" SRJW TO SF TRANSITION AT ROOF EDGE 6" SRJW ROOF TO WALL COVER NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. FORMED ALUMINUM ROOF END CAP SET IN SEALANT AND SCREWED TO ROOF COVER. (SEALANT BY OTHERS) SEAL BETWEEN ROOF FRAME AND BACK SIDE OF END CAP WITH SILICONE SEALANT. (SEALANT BY OTHERS) FORMED ALUMINUM ROOF END CAP SET IN SEALANT AND SCREWED TO ROOF COVER. (SEALANT BY OTHERS) 1 1/2" 6" SRJW TO ESC TRANSITION AT ROOF EDGE 6" SRJW ROOF TO WALL COVER NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. FORMED ALUMINUM WALL END CAP SET IN SEALANT. (SEALANT BY OTHERS) REGLET AND COUNTER FLASHING (BY OTHERS) REGLET AND COUNTER FLASHING (BY OTHERS) SEAL BETWEEN ROOF FRAME AND BACK SIDE OF END CAP WITH SILICONE SEALANT. (SEALANT BY OTHERS) 1 1/2" SF WALL COVER 6" SRJW TO SF TRANSITION AT ROOF EDGE 6" SRJW ROOF TO WALL COVER NOTE: WATERSTOP OF ROOF COVER TO BE DRAPED INTO THE SECONDARY SEAL OF THE WALL COVER AT ROOF LEVEL OR SLIGHTLY BELOW TO DIVERT WATER DOWN THE VERTICAL. FORMED ALUMINUM ROOF END CAP SET IN SEALANT AND SCREWED TO ROOF COVER. (SEALANT BY OTHERS) SRJW ROOF TO WALL COVER SRJ ROOF TO ROOF COVER SRJW TO SRJ TRANSITION FORMED ALUMINUM SPLICE COVERS 5.50

219 Section 6 - Parking/Open Air Structure Covers Joint Size Page Nos. Joint Size Page Nos. 1" to 4" (6.3, 6.4) Metal - Cast in place 4" to 12" ( ) Parking Compression Seal 1" to 4" (6.5, 6.6) 7/8" to 3-7/16" (6.7, 6.8) Parking Mechanically Fastened 4" to 12" ( ) 6" to 16" (6.15, 6.18) Mechanically Fastened 1-1/2" to 3-1/2" " (6.9, 6.10) Plaza Deck 1" to 4" ( ) 6.1

220 Section 6 - Parking / Open Air Structure Covers Compression Seal Covers Use of elastomeric concrete on winged compressions seals allows for resilient "nosing" system but is messy and difficult to apply. Integral nosing provided in Zip Block, the one-piece winged compression seal that eliminates the need for elastomeric concrete. Metal Covers Incorporate load transference to prevent damage to the cover system. Heavy-duty models provide the HS-20 load capabilities. 6.2

221 ZB & ZBW 100/400 Series Technical Data: Seal Material - EPDM Color Black Durometer 74 Shore A, ASTM D2240 Epoxy 2 part Gel Time 35 minutes, ASTM C881 Bond Strength (2 day cure) 2,232 psi, ASTM C882 Bond Strength (14 day cure) 2,460 psi, ASTM C880 Compressive Modulus 250,100 psi, ASTM D695 Edge Sealant Tack free time 25 minutes, ASTM C679 Product Description: The ZB expansion joint system is a one-piece, extruded EPDM elastomeric seal with integral nosings, bonded into a high-strength epoxy bedding, designed for use in parking deck applications. The ensuing system is then sealed on each side with a urethane sealant, resulting in an extremely durable and watertight joint system. Use This Cover For: Floor expansion joint cover in parking structures. Creating a watertight joint. Replacing damaged elastomeric concrete joint cover systems. Performance Characteristics: The EPDM seal allows for movement while the integral nosing eliminates the need for messy elastomeric concrete. Standard Finishes: Seal is available in black only. Installation Guidelines: Blockouts must be solid, free of voids, dust, release agents or any other contaminants that would inhibit the bond of the primer. Sandblasting is recommended. The blockouts must be flat, level and parallel. The base of the blockout must be flat (along the length of the joint) to within +/-1/8" [3.18mm] and level (across the joint) to within +/-1/8" [3.18mm]. Any locations of edge raveling, spalling or other damage to the blockout surfaces must be repaired with a non-latex high strength grout that will provide a sound and square blockout. Surface temperatures should be above 40º but below 80º. Mix epoxy and apply to base of blockout. Push seal into joint opening and set wings into epoxy. Weigh down seal and let set 8 hours. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

222 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT ZB '' (25mm) 0.50'' (13mm) 1.50'' (38mm) 8.00'' (203mm) 3.50'' (89mm) 0.75'' (19mm) ZB '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 9.00'' (229mm) 3.50'' (89mm) 0.75'' (19mm) ZB '' (76mm) 1.50'' (38mm) 4.50'' (114mm) 10.00'' (254mm) 3.50'' (89mm) 0.75'' (19mm) ZB '' (102mm) 2.00'' (51mm) 6.00'' (152mm) 11.00'' (279mm) 3.50'' (89mm) 0.75'' (19mm) ZBW '' (25mm) 0.50'' (13mm) 1.50'' (38mm) 4.50'' (114mm) 3.50'' (89mm) 0.75'' (19mm) ZBW '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 5.50'' (140mm) 3.50'' (89mm) 0.75'' (19mm) ZBW '' (76mm) 1.50'' (38mm) 4.50'' (114mm) 6.50'' (165mm) 3.50'' (89mm) 0.75'' (19mm) ZBW '' (102mm) 2.00'' (51mm) 6.00'' (152mm) 7.50'' (191mm) 3.50'' (89mm) 0.75'' (19mm) EPDM WINGED SEAL EXPOSED SURFACE HEIGHT HEIGHT JOINT ZB (TYP.) EXPOSED SURFACE EXTRUDED EPDM COMPRESSION SEAL (COLOR: BLACK) EDGE SEALANT HEIGHT CONT. FORMED ALUM. WALL LEDGE ANGLE JOINT ZBW (TYP.) 6.4

223 HB 100/400 Series Technical Data: Seal Material EPDM Color Black Durometer 74 Shore A, ASTM D2240 Epoxy 2 part Gel Time 35 minutes, ASTM C881 Bond Strength (2 day cure) 2,232 psi, ASTM C882 Bond Strength (14 day cure) 2,460 psi, ASTM C880 Compressive Modulus 250,100 psi, ASTM D695 Product Description: The HB series expansion joint system is a one-piece, extruded EPDM elastomeric seal with integral epoxy reservoirs, bonded into a highstrength epoxy bedding, designed for use in parking deck and other watertight concrete deck applications. Proper installations will result in an extremely durable and watertight joint system, which achieves +/- 50% movement capability. Use This Cover For: Seismic applications in parking and other areas with vehicular access. Performance Characteristics: The closed cell design allows this watertight joint system to achieve a +/- 50% movement capability. Standard Finishes: Seal is available in black only. Installation Guidelines: The joint must be sandblasted to expose new concrete and remove all form release agents and other foreign materials. The surface of the joint must be clean and free from any loose dust, dirt, debris and oils that would affect the installation of the seal, or adhesion of the epoxy. The two-part epoxy must be mixed in the field and has a gel time between 20 to 35 minutes (depending on the temperature outside). For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

224 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT HB '' (25mm) 0.50'' (13mm) 1.50'' (38mm) 1.00'' (25mm) N/A N/A HB '' (51mm) 1.00'' (25mm) 3.00'' (76mm) 2.00'' (51mm) N/A N/A HB '' (76mm) 1.50'' (38mm) 4.50'' (114mm) 3.00'' (76mm) N/A N/A HB '' (102mm) 2.00'' (51mm) 6.00'' (152mm) 4.00'' (102mm) N/A N/A COMPRESSION SEAL EXPOSED SURFACE JOINT HB (TYP.) COMPRESSION SEAL EXPOSED SURFACE JOINT HB (TYP. - Corner) 6.6

225 HBF 100/400 Series Technical Data: Seal Material Closed cell neoprene Color - Black Physical properties Tensile Strength 125 psi (0.86 Mpa) min, ASTM D-412 Hardness Shore 00, ASTM D-2240 Product Description: An extruded neoprene compression seal incorporating built in reservoirs for epoxy adhesive. Use This Cover For: Small movement expansion joint applications. Perimeter joints around buildings. Vertical wall applications. Slab-to-wall conditions. Exterior columns. Elevator shafts. Stair towers. Performance Characteristics: HBF remains in contact with the joint walls through normal compression and tension of their shape and are bonded to the joint with a high quality epoxy adhesive. Standard Finishes: Seal is available in black only. Installation Guidelines: The joint must be sandblasted to expose new concrete and remove all form release agents and other foreign materials. The surface of the joint must be clean and free from any loose dust, dirt, debris and oils that would affect the installation of the seal, or adhesion of the epoxy. The two-part epoxy must be mixed in the field and has a gel time between 20 to 35 minutes (depending on the temperature outside). For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

226 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT HBF '' (22mm) 0.44'' (11mm) 1.25'' (32mm) 0.88'' (22mm) N/A N/A HBF '' (33mm) 0.69'' (17mm) 1.88'' (48mm) 1.31'' (33mm) N/A N/A HBF '' (43mm) 0.88'' (22mm) 2.50'' (64mm) 1.69'' (43mm) N/A N/A HBF '' (54mm) 1.13'' (29mm) 3.13'' (79mm) 2.13'' (54mm) N/A N/A HBF '' (65mm) 1.38'' (35mm) 3.75'' (95mm) 2.56'' (65mm) N/A N/A HBF '' (87mm) 1.81'' (46mm) 5.00'' (127mm) 3.44'' (87mm) N/A N/A EXTRUDED NEOPRENE SEAL EXPOSED SURFACE JOINT HBF (TYP.) EXTRUDED NEOPRENE SEAL EXPOSED SURFACE JOINT HBF (TYP. - Corner) 6.8

227 CSAB Series Technical Data: Wing Seal Material Santoprene Durometer 73 Shore A Color Black. Anchor Blocks Material Neoprene Durometer 60 Shore A Min Internal Reinforcing A36 Steel Product Description: C/S model CSAB is a heavy-duty elastomeric expansion joint system designed for use in parking structures, loading docks, and other areas requiring vehicular or forklift traffic. The system is composed of a Santoprene wing seal and heavy-duty neoprene anchor blocks with integrally-molded steel reinforcement plate, mechanically secured to the structure. Anchor blocks are supplied in 4-0 lengths, molded with interlocking ends. Seal supplied in 50-0 lengths. Seal splices to be heat-welded in the field. Use This Cover For: Seismic applications in parking and other areas with vehicular access. Performance Characteristics: Parking structure seal system featuring bolt down heavy-duty anchor blocks. ADA compliant. Standard Finishes: Material UV-resistant, black (all components). Installation Guidelines: Blockouts are required by this model and should be straight and parallel. Sandblast the joint to clean it. Compress seal and insert into the joint until the wings are flush with the bottom of the blockout. Roll back wing and apply C/S supplied tack coat. Reposition wings and anchor blocks into blockout and anchor with C/S supplied fasteners. Please refer to the complete C/S installation instructions at To download detail, specs & photos visit For technical and design assistance call

228 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT CSAB '' (38mm) 0.75'' (19mm) 2.00'' (51mm) 9.50'' (241mm) 4.25'' (108mm) 1.50'' (38mm) CSAB '' (54mm) 1.25'' (32mm) 2.75'' (70mm) 10.13'' (257mm) 4.25'' (108mm) 1.50'' (38mm) CSAB '' (73mm) 1.25'' (32mm) 3.75'' (95mm) 10.88'' (276mm) 4.25'' (108mm) 1.50'' (38mm) CSAB '' (89mm) 2.00'' (51mm) 5.75'' (146mm) 11.50'' (292mm) 4.25'' (108mm) 1.50'' (38mm) CSABW '' (38mm) 0.75'' (19mm) 2.00'' (51mm) 5.25'' (133mm) 4.25'' (108mm) 1.50'' (38mm) CSABW '' (54mm) 1.25'' (32mm) 2.75'' (70mm) 5.88'' (149mm) 4.25'' (108mm) 1.50'' (38mm) CSABW '' (73mm) 1.25'' (32mm) 3.75'' (95mm) 6.63'' (168mm) 4.25'' (108mm) 1.50'' (38mm) CSABW '' (89mm) 2.00'' (51mm) 5.75'' (1406mm) 7.25'' (184mm) 4.25'' (108mm) 1.50'' (38mm) EXPOSED SURFACE ELASTOMERIC ANCHOR BLOCK HEIGHT HEIGHT JOINT CSAB (TYP. ) EXPOSED SURFACE ELASTOMERIC ANCHOR BLOCK HEIGHT JOINT CSABW (TYP.) 6.10

229 KB & KBW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Vapor Barrier Material Polyethylene Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2582 Turnbar Cast Aluminum SR-319F Product Description: All metal expansion joint cover for parking structures designed to eliminate damage often caused by dynamic wheel loads. The unique turnbar assembly and bolt housing of the KB cover shields the assembly from damage caused by impact of vehicular traffic and allows for the vertical displacement of the adjacent floor slabs, without the damage often found in conventional seismic cover systems. Use This Cover For: Seismic applications in parking and other areas with vehicular access. Standard vehicular loading (3,000 lb. point load per IBC 2009) Modles for increased loading (HS-20, etc.) available please consult factroy Performance Characteristics: Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. The design provides full impact load transference through turnbar and base frames, eliminating potential loosening and failure of center bolt typical of other flush plate designs. Standard Finishes: Mill finish. Installation Guidelines: Blockouts must be flat, level and parallel. The base of the blockout must be flat (along the length of the joint) to within +/-1/16" and level (across the joint) to within +/-1/16". Install base frames with C/S supplied fasteners and insert secondary seal. Slide turnbars into frames and align with holes in center plate. Fasten center plate to turnbar with C/S supplied fasteners. Remaining space in blockouts to be filled with elastomeric concrete. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

230 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT KB '' (102mm) 2.00'' (51mm) 6.50'' (165mm) 11.25'' (286mm) 6.50'' (165mm) 2.00'' (51mm) KB '' (127mm) 2.00'' (51mm) 9.25'' (235mm) 15.25'' (387mm) 8.00'' (203mm) 2.00'' (51mm) KB '' (152mm) 2.00'' (51mm) 9.50'' (241mm) 16.25'' (413mm) 8.00'' (203mm) 2.00'' (51mm) KB '' (178mm) 3.00'' (76mm) 12.50'' (318mm) 19.25'' (489mm) 9.00'' (229mm) 2.00'' (51mm) KB '' (203mm) 3.00'' (76mm) 12.50'' (318mm) 20.25'' (514mm) 9.00'' (229mm) 2.00'' (51mm) KB '' (229mm) 4.50'' (114mm) 15.00'' (381mm) 23.25'' (591mm) 10.00'' (254mm) 2.00'' (51mm) KB '' (254mm) 4.50'' (114mm) 15.50'' (394mm) 24.25'' (616mm) 10.00'' (254mm) 2.00'' (51mm) KB '' (279mm) 5.50'' (140mm) 18.50'' (470mm) 27.25'' (692mm) 11.00'' (279mm) 2.00'' (51mm) KB '' (305mm) 5.50'' (140mm) 18.50'' (470mm) 28.25'' (718mm) 11.00'' (279mm) 2.00'' (51mm) KBW '' (102mm) 3.00'' (76mm) 5.25'' (133mm) 7.63'' (194mm) 6.50'' (165mm) 2.00'' (51mm) KBW '' (127mm) 4.00'' (102mm) 7.75'' (197mm) 10.13'' (257mm) 8.00'' (203mm) 2.00'' (51mm) KBW '' (152mm) 4.00'' (102mm) 7.75'' (197mm) 11.13'' (283mm) 8.00'' (203mm) 2.00'' (51mm) KBW '' (178mm) 5.50'' (140mm) 10.25'' (260mm) 13.13'' (333mm) 9.00'' (229mm) 2.00'' (51mm) KBW '' (203mm) 5.50'' (140mm) 10.25'' (260mm) 14.13'' (359mm) 9.00'' (229mm) 2.00'' (51mm) KBW '' (229mm) 7.25'' (184mm) 12.75'' (324mm) 16.13'' (410mm) 10.00'' (254mm) 2.00'' (51mm) KBW '' (254mm) 7.25'' (184mm) 12.75'' (324mm) 17.13'' (435mm) 10.00'' (254mm) 2.00'' (51mm) KBW '' (279mm) 8.75'' (222mm) 15.25'' (387mm) 19.25'' (489mm) 11.00'' (279mm) 2.00'' (51mm) KBW '' (305mm) 8.75'' (222mm) 15.25'' (387mm) 20.13'' (511mm) 11.00'' (279mm) 2.00'' (51mm) ALUMINUM COVER PLATE EXPOSED SURFACE HEIGHT HEIGHT JOINT KB (TYP. ) EXPOSED SURFACE ALUMINUM COVER PLATE HEIGHT JOINT KBW (TYP.) 6.12

231 KBC & KBCW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Vapor Barrier Material Polyethylene Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2583 Turnbar Cast Aluminum SR-319-F Product Description: All metal expansion joint cover for parking structures designed to eliminate damage often caused by dynamic wheel loads. The unique turnbar assembly and bolt housing of the KB cover shields the assembly from damage caused by impact of vehicular traffic and allows for the vertical displacement of the adjacent floor slabs, without the damage often found in conventional seismic cover systems. This model is specifically designed for cast in place installation. Use This Cover For: Seismic applications in parking and other areas with vehicular access. Standard vehicular loading (3,000 lb. point load per IBC 2009) Modles for increased loading (HS-20, etc.) available please consult factroy Cast-In-Place Model designed for post-tensioned slab applications. Performance Characteristics: Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. The design provides full impact load transference through turnbar and base frames, eliminating potential loosening and failure of center bolt typical of other flush plate designs. Standard Finishes: Mill finish. Installation Guidelines: Frames require some setup for casting purposes using wood blocks and sheathing by others. Base frames get cast into concrete deck. Apply waterstop over base frame and attach top frame. Slide turnbars into frames and align with holes in center plate. Fasten center plate to turnbar with C/S supplied fasteners. For the complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

232 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT KBC '' (102mm) 1.25'' (32mm) 6.50'' (165mm) 11.44'' (291mm) N/A N/A KBC '' (127mm) 2.50'' (64mm) 9.50'' (241mm) 14.44'' (367mm) N/A N/A KBC '' (152mm) 2.50'' (64mm) 9.50'' (241mm) 15.44'' (392mm) N/A N/A KBC '' (178mm) 3.25'' (83mm) 12.50'' (318mm) 18.38'' (467mm) N/A N/A KBC '' (203mm) 3.25'' (83mm) 12.50'' (318mm) 19.38'' (492mm) N/A N/A KBC '' (229mm) 4.00'' (102mm) 16.25'' (413mm) 22.44'' (570mm) N/A N/A KBC '' (254mm) 4.50'' (114mm) 16.25'' (413mm) 23.44'' (595mm) N/A N/A KBC '' (279mm) 5.00'' (127mm) 19.00'' (483mm) 26.44'' (672mm) N/A N/A KBC '' (305mm) 5.00'' (127mm) 19.00'' (483mm) 27.44'' (697mm) N/A N/A KBCW '' (102mm) 2.75'' (70mm) 5.00'' (127mm) 7.75'' (197mm) N/A N/A KBCW '' (127mm) 4.00'' (102mm) 7.75'' (197mm) 9.75'' (248mm) N/A N/A KBCW '' (152mm) 4.00'' (102mm) 7.75'' (197mm) 10.75'' (273mm) N/A N/A KBCW '' (178mm) 5.75'' (146mm) 10.25'' (260mm) 12.69'' (322mm) N/A N/A KBCW '' (203mm) 5.75'' (146mm) 10.25'' (260mm) 13.69'' (348mm) N/A N/A KBCW '' (229mm) 7.00'' (178mm) 13.00'' (330mm) 15.69'' (398mm) N/A N/A KBCW '' (254mm) 7.00'' (178mm) 13.00'' (330mm) 16.69'' (424mm) N/A N/A KBCW '' (279mm) 8.75'' (222mm) 15.50'' (394mm) 18.69'' (475mm) N/A N/A KBCW '' (305mm) 8.75'' (222mm) 15.50'' (394mm) 19.69'' (500mm) N/A N/A ALUMINUM COVER PLATE EXPOSED SURFACE JOINT KBC (TYP. ) EXPOSED SURFACE BOTTOM FRAME COVER PLATE TOP FRAME WATERSTOP JOINT KBCW (TYP. ) 6.14

233 PTC & PTCW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Sheet 6061-T6, 3003 H14, 5005 H34, ASTM-B209. Vapor Barrier Material Polyethylene Color Black 3 Tensile Strength 275 lbs., ASTM-882 Puncture Strength 72 lbs., ASTM-4833 PPT Resistance 45 lbs., ASTM-2583 Product Description: PTC and PTCW are seismic floor covers specifically designed for parking structure application. These systems are designed to accommodate seismic and live load movements including vertical deflection of the adjacent floor slab. These systems are ADA compliant with moisture and fire barrier options available. Use This Cover For: Seismic applications in parking and other areas with vehicular access. Structures with lots of vertical deflection. Performance Characteristics: The design of PTC parking expansion joint cover allows for the vertical displacement of the adjacent floor slabs without the damage often found in conventional seismic cover systems. The unique damper system prevents the cover from "clunking" noisily from sideto-side under dynamic traffic loads. Standard Finishes: Mill finish. Installation Guidelines: Joint Width and Blockout sizes must be in accordance with the architectural details and C/S shop drawings before installation can begin. Blockouts must be flat and level. All repairs to the mounting surfaces must be done prior to the installation of the joint cover system. Apply waterstop to joint opening and bottom of blockout. Install base frame & sloped frame over waterstop. Set compression springs as shown and apply cover plate. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

234 MODEL JOINT MINIMUM MAXIMUM EXPOSED OPENING OPENING SURFACE HEIGHT PTC '' (152mm) 0.00'' (0mm) 11.00'' (279mm) 19.63'' (498mm) 10.75'' (273mm) 1.50'' (38mm) PTC '' (178mm) 0.00'' (0mm) 12.00'' (305mm) 20.63'' (524mm) 10.75'' (273mm) 1.50'' (38mm) PTC '' (203mm) 0.00'' (0mm) 13.00'' (330mm) 21.63'' (549mm) 10.75'' (273mm) 1.50'' (38mm) PTC '' (229mm) 0.00'' (0mm) 14.00'' (356mm) 22.63'' (575mm) 10.75'' (273mm) 1.50'' (38mm) PTC '' (254mm) 0.00'' (0mm) 16.00'' (406mm) 24.63'' (625mm) 10.75'' (273mm) 1.50'' (38mm) PTC '' (279mm) 0.00'' (0mm) 17.00'' (432mm) 25.88'' (657mm) 12.00'' (305mm) 1.50'' (38mm) PTC '' (305mm) 0.00'' (0mm) 19.00'' (483mm) 27.38'' (695mm) 12.50'' (318mm) 1.50'' (38mm) PTC '' (330mm) 0.00'' (0mm) 20.50'' (521mm) 28.88'' (733mm) 13.00'' (330mm) 1.50'' (38mm) PTC '' (356mm) 0.00'' (0mm) 22.00'' (559mm) 30.38'' (772mm) 13.50'' (343mm) 1.50'' (38mm) PTC '' (381mm) 0.00'' (0mm) 23.50'' (597mm) 31.88'' (810mm) 14.00'' (356mm) 1.50'' (38mm) PTC '' (406mm) 0.00'' (0mm) 25.00'' (635mm) 33.38'' (848mm) 14.50'' (368mm) 1.50'' (38mm) PTCW '' (152mm) 0.00'' (0mm) 11.25'' (286mm) 15.00'' (381mm) 10.75'' (273mm) 1.50'' (38mm) PTCW '' (178mm) 0.00'' (0mm) 12.25'' (311mm) 16.00'' (406mm) 10.75'' (273mm) 1.50'' (38mm) PTCW '' (203mm) 0.00'' (0mm) 13.25'' (337mm) 17.00'' (432mm) 10.75'' (273mm) 1.50'' (38mm) PTCW '' (229mm) 0.00'' (0mm) 14.25'' (362mm) 18.00'' (457mm) 10.75'' (273mm) 1.50'' (38mm) PTCW '' (254mm) 0.00'' (0mm) 16.25'' (413mm) 20.00'' (508mm) 10.75'' (273mm) 1.50'' (38mm) PTCW '' (279mm) 0.00'' (0mm) 17.50'' (445mm) 21.25'' (540mm) 12.00'' (305mm) 1.50'' (38mm) PTCW '' (305mm) 0.00'' (0mm) 19.00'' (483mm) 22.75'' (578mm) 12.50'' (318mm) 1.50'' (38mm) PTCW '' (330mm) 0.00'' (0mm) 20.50'' (521mm) 24.25'' (616mm) 13.00'' (330mm) 1.50'' (38mm) PTCW '' (356mm) 0.00'' (0mm) 22.00'' (559mm) 25.75'' (654mm) 13.50'' (343mm) 1.50'' (38mm) PTCW '' (381mm) 0.00'' (0mm) 23.50'' (597mm) 27.25'' (692mm) 14.00'' (356mm) 1.50'' (38mm) PTCW '' (406mm) 0.00'' (0mm) 25.00'' (635mm) 28.75'' (730mm) 14.50'' (368mm) 1.50'' (38mm) EXPOSED SURFACE ALUMINUM COVER PLATE HEIGHT 2" JOINT " PTC (TYP. ) EXPOSED SURFACE ALUMINUM COVER PLATE HEIGHT JOINT PTCW (TYP. ) 6.16

235 PDA & PDAW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Primary Seal Single Durometer - 78 Shore A Available in Black Standard Loading 500 lbs. Wing Seal Material - PVC Durometer - 65 Shore A Color - Black Product Description: This cover is specifically designed for exterior plaza deck applications. Frames available in 2, 3, 4 and 5 depths. Use This Cover For: Suitable for exterior plaza decks. Split slab construction. 1 to 4 joints. Performance Characteristics: The primary seal expands and contracts to allow for movement and finishes over wing seal to create waterproof application. Wing seal is tied directly into deck waterproofing. Standard Finishes: Mill finish. Clear anodize available. Gaskets are black. Installation Guidelines: Install frames with C/S supplied fasteners. Insert wing seal, then primary seal into frames and attach aluminum cap. Tie wing seal into deck waterproofing. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

236 MODEL JOINT MINIMUM MAXIMUM EXPOSED PROFILE OPENING OPENING SURFACE HEIGHT PDA '' (25mm) 0.75'' (19mm) 3.25'' (83mm) 4.75'' (121mm) N/A VARIES PDA '' (51mm) 0.75'' (19mm) 3.25'' (83mm) 4.75'' (121mm) N/A VARIES PDA '' (76mm) 1.50'' (38mm) 6.50'' (166mm) 6.75'' (171mm) N/A VARIES PDA '' (102mm) 1.50'' (38mm) 6.50'' (166mm) 6.75'' (171mm) N/A VARIES PDAW '' (25mm) 0.75'' (19mm) 3.25'' (83mm) 4.81'' (122mm) N/A VARIES PDAW '' (51mm) 0.75'' (19mm) 3.25'' (83mm) 4.81'' (122mm) N/A VARIES PDAW '' (76mm) 1.50'' (38mm) 6.50'' (166mm) 6.81'' (173mm) N/A VARIES PDAW '' (102mm) 1.50'' (38mm) 6.50'' (166mm) 6.81'' (173mm) N/A VARIES EXTRUDED ALUMINUM TOP CAP ALIGNMENT PIN EXPOSED SURFACE COMPRESSION SEAL PROFILE HEIGHT EXTRUDED WING SEAL JOINT FLOOR FRAME ASSEMBLY (MADE FROM EXTRUDED ALUMINUM COMPONENTS) PDA (TYP. ) COMPRESSION SEAL EXTRUDED ALUMINUM TOP CAP ALIGNMENT PIN FORMED ALUMINUM WALL CAP EXTRUDED WING SEAL PROFILE HEIGHT 2" FLOOR FRAME ASSEMBLY (MADE FROM EXTRUDED ALUMINUM COMPONENTS) PDAW (TYP. ) 6.18

237 PDS & PDSW Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Stainless Steel Type 304 ASTM A167, A240A, A240M Primary Seal Single Durometer - 78 Shore A Available in Black Standard Loading 500 lbs. Wing Seal Material - PVC Durometer - 65 Shore A Color - Black Product Description: This cover is specifically designed for exterior plaza deck applications. Frames available in 2, 3, 4 and 5 depths. Use This Cover For: Suitable for exterior plaza decks. Split slab construction. 1 to 4 joints. Performance Characteristics: The primary seal expands and contracts to allow for movement and finishes over wing seal to create waterproof application. Wing seal is tied directly into deck waterproofing. Standard Finishes: Steel No. 4 finish. Gaskets are black. Installation Guidelines: Install frames with C/S supplied fasteners. Insert wing seal, then primary seal into frames and attach stainless steel cap. Tie wing seal into deck waterproofing. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

238 MODEL JOINT MINIMUM MAXIMUM EXPOSED PROFILE OPENING OPENING SURFACE HEIGHT PDS '' (25mm) 0.75'' (19mm) 3.25'' (83mm) 4.75'' (121mm) N/A VARIES PDS '' (51mm) 0.75'' (19mm) 3.25'' (83mm) 4.75'' (121mm) N/A VARIES PDS '' (76mm) 1.25'' (38mm) 6..50'' (166mm) 6.75'' (171mm) N/A VARIES PDS '' (102mm) 1.25'' (38mm) 6.50'' (166mm) 6.75'' (171mm) N/A VARIES PDSW '' (25mm) 0.75'' (19mm) 3.25'' (83mm) 4.81'' (122mm) N/A VARIES PDSW '' (51mm) 0.75'' (19mm) 3.25'' (83mm) 4.81'' (122mm) N/A VARIES PDSW '' (76mm) 1.25'' (38mm) 6.50'' (166mm) 6.81'' (173mm) N/A VARIES PDSW '' (102mm) 1.25'' (38mm) 6.50'' (166mm) 6.81'' (173mm) N/A VARIES STAINLESS STEEL FORMED TOP CAP EXPOSED SURFACE COMPRESSION SEAL ALIGNMENT PIN PROFILE HEIGHT EXTRUDED WING SEAL JOINT FLOOR FRAME ASSEMBLY (MADE FROM EXTRUDED ALUMINUM COMPONENTS) PDS (TYP. ) COMPRESSION SEAL STAINLESS STEEL FORMED TOP CAP ALIGNMENT PIN FORMED ALUMINUM WALL CAP EXTRUDED WING SEAL PROFILE HEIGHT JOINT FLOOR FRAME ASSEMBLY (MADE FROM EXTRUDED ALUMINUM COMPONENTS) PDSW (TYP. ) 6.20

239 PDS-BT & PDSW-BT Series Technical Data: Aluminum Extrusion C/S uses multiple alloys & tempers which are established to be the most appropriate for the given use of individual parts. Will be one of the following:(6063-t5, T6, T52) (6061-T5, T6, T51) (6105-T5, T6) (6005-T5) (6005A-T5, T61) Stainless Steel Type 304 ASTM A167, A240A, A240M Primary Seal Single Durometer 78 Shore A Available in Black Standard Loading 2,000 lbs. Wing Seal Material - PVC Durometer - 65 Shore A Color - Black Product Description: This cover is specifically designed for exterior plaza deck applications. Frames available in 2, 3, 4 and 5 depths. Use This Cover For: Suitable for exterior plaza decks. Parking deck applications. Split slab construction. 1 and 4 joints. Performance Characteristics: The primary seal expands and contracts to allow for movement and finishes over wing seal to create waterproof application. Wing seal is tied directly into deck waterproofing. Standard Finishes: Steel No. 4 finish. Gaskets are black. Installation Guidelines: Install frames with C/S supplied fasteners. Insert wing seal, then primary seal into frames and attach stainless steel cap. Tie wing seal into deck waterproofing. For complete installation instructions, please visit To download detail, specs & photos visit For technical and design assistance call

240 MODEL JOINT MINIMUM MAXIMUM EXPOSED PROFILE OPENING OPENING SURFACE HEIGHT PDS-100BT 1.00'' (25mm) 0.75'' (19mm) 3.25'' (83mm) 4.75'' (121mm) N/A VARIES PDS-200BT 2.00'' (51mm) 0.75'' (19mm) 3.25'' (83mm) 4.75'' (121mm) N/A VARIES PDS-300BT 3.00'' (76mm) 1.50'' (38mm) 6.50'' (166mm) 6.75'' (171mm) N/A VARIES PDS-400BT 4.00'' (102mm) 1.50'' (38mm) 6.50'' (166mm) 6.75'' (171mm) N/A VARIES PDSW-100BT 1.00'' (25mm) 0.75'' (19mm) 3.25'' (83mm) 4.81'' (122mm) N/A VARIES PDSW-200BT 2.00'' (51mm) 0.75'' (19mm) 3.25'' (83mm) 4.81'' (122mm) N/A VARIES PDSW-300BT 3.00'' (76mm) 1.50'' (38mm) 6.50'' (166mm) 6.81'' (173mm) N/A VARIES PDSW-400BT 4.00'' (102mm) 1.50'' (38mm) 6.50'' (166mm) 6.81'' (173mm) N/A VARIES STAINLESS STEEL FORMED TOP CAP ALIGNMENT PIN EXPOSED SURFACE COMPRESSION SEAL PROFILE HEIGHT EXTRUDED WING SEAL JOINT FLOOR FRAME ASSEMBLY (MADE FROM EXTRUDED ALUMINUM COMPONENTS) PDS-BT (TYP. ) COMPRESSION SEAL STAINLESS STEEL FORMED TOP CAP FORMED ALUMINUM WALL CAP ALIGNMENT PIN EXTRUDED WING SEAL PROFILE HEIGHT JOINT FLOOR FRAME ASSEMBLY (MADE FROM EXTRUDED ALUMINUM COMPONENTS) PDSW-BT (TYP. ) 6.22

241 Section 7 - Fire Barriers Joint Size Description Page Nos. Ultra Block 1-4 A pre-engineered, patented, flexible ( ) textile fiberglass roll material with a fiberglass matte facing, containing approximately 30% by weight unexpanded vermiculite. Fire Barriers Reflex Multiflex 1-4 Stainless steel foil drape with block ( ) insulation affords maximum economy in material and installation "Sandwich" assembly of layers of stainless (7.11) steel foil and insulation contained in a stainless steel mesh. Standard barrier allows up to 50% lateral shear in floor applications. FB-97 7 and up Multiple drape configuration of stainless (7.13) foil and insulation utilizing air pockets for additional insulation performance. Sliding frame available for 100% lateral shear applications in floor. 7.1

242 Section 7 - Fire Barriers What to Consider One of the most confusing aspects of determining the appropriate expansion joint cover is selecting the proper fire barrier when a fire rated joint is required. The right fire barrier to be used depends on how wide the joint is, how much movement is required, the hourly fire-rating needed, substrate material and other factors. C/S offers four different fire barriers to satisfy the vast array of combinations. While there are general guidelines that we follow in selecting fire barriers, there are always exceptions to the rules. If you re unsure of which fire barrier to use, we encourage you to contact us for recommendations. General Guidelines Fire barrier assemblies are designed to work with a given cover system in order to provide any where from a 1-hour to a 4-hour rating. It is critical that expansion joint systems incorporate a fire barrier equal in rating to the substrate being penetrated by the joint. "Standard" barriers are designed for +/- 50% of the nominal joint width. Most "Standard" barriers can accommodate lateral movement of about 25% to 50% of the nominal joint width. Although wall joint covers will most likely stop at the ceiling, any fire barrier system in the wall must continue to the underside of the slab / floor fire barrier above in order to insure barrier integrity. No fire barrier system can close to 0". The clear space should be unmistakably established for the specific system. 7.2

243 UlTRA BloCk Joint Fire Stopping System: 2-Hour, 3-Hour, 4-Hour Fire Rated. MANUFACTURER Backer Rod Mfg. Inc N Broadway Denver, CO Phone: (800) (303) Fax: (303) Web: Product Description: ULTRA BLOCK is a pre-engineered, patented, flexible textile fiberglass roll material with a fiberglass matte facing, containing approximately 30% by weight unexpanded vermiculite. Specific Uses: ULTRA BLOCK, when used together with an approved sealant, provides a 2-hour, 3-hour, or 4-hour fire rated joint system as designated by design configuration, which is capable of withstanding +/-50% expansion and contraction. Most sealant manufacturers in the United States have tested one or more of their sealants in a UL classified ULTRA BLOCK system ranging in joint size from 1/2 up to 7. Approved sealant manufacturers include: Dow Corning General Electric Mameco(Tremco Inc) C R Lawrence Lymtal Pecora Quaker Rhone-Poulenc Inc Sika Sonneborn(Chemrex Inc) Specified Technologies Inc Benefits Resiliency: To be an effective fire blocking joint packing system, a product must remain highly resilient and must completely fill the moving joint for a great number of years. In most packed and caulked joints, examination of the resiliency of the forming material is difficult to check, as the material is covered up with sealant. Many joint packing materials, such as mineral wool and ceramic fiber, are not designed to handle joint movement and may fall out or slump in the joint when subjected to continuous joint expansion and contraction. Under fire situations, the fire blocking material must be in the same condition as when it was installed, meaning that the material must completely fill the void in order to block a fire. ULTRA BLOCK has a unique patented, hinged design and composition that remains highly resilient under the most extreme conditions. Structurally Tested: The structural testing of ULTRA BLOCK was performed by Hauser Laboratories. The test was run on a +/-50% joint movement. Mineral wool and ceramic fiber joint packing materials were also tested. The joints were packed in the fully open position and were under the 25% joint side compression. The test ran continuously until either failure To download detail, specs & photos visit For technical and design assistance call

244 occurred or the test was terminated. Failure of both the mineral wool and ceramic fiber materials occurred in under 600 cycles, or 1.6 years. The ULTRA BLOCK successfully performed for over 28,000 cycles without failure or loss of resiliency, representing 76 years of service at one cycle per day! Fire Stopping: ULTRA BLOCK has been proven to withstand the test of time in joint expansion and contraction. The ULTRA BLOCK system also has avery unique feature not present in either mineral wool or ceramic fiber material. ULTRA BLOCK contains vermiculite, which expands when exposed to heat. As the vermiculite expands it produces thousands of reflective shields that reflect heat back away from the expansion joint. When exposed to fire on the caulked or uncaulked side there is no passage of destructive heat to the sealant bead on the opposite side. ULTRA BLOCK is a fire blocking material in fire rated joints that will be in place if and when needed. It is the only fire rated joint system today, which gives this protection using standard construction sealants! In addition, it does not require metal cover plates as some systems do. Composition and Materials: All ULTRA BLOCK systems are manufactured in accordance with project requirements. ULTRA BLOCK is manufactured in various widths and thicknesses, depending on the joint width, and sold in rolls. EASY INSTAllATIoN ULTRA BLOCK requires no cutting, fitting, or fabrication. Simply open the bag, unwind the roll, fold in half with the matte side facing outward, compress and slide it in the joint to required depth. Apply sealant per manufacturers instructions. When joining ends of rolls, cut each end at a 45 angle, alternating cuts so that the folded over ULTRA BLOCK forms an interlocking v-shape. TECHNICAl INFoRMATIoN All ULTRA BLOCK systems are covered with a nominal 1/2 depth elastomeric sealant (see list of manufacturers). System designs can range from 1-hour, 2-hour, 3-hour or 4-hour fire ratings and joint widths from 1/2 up to 25 wide. ULTRA BLOCK systems allow the mechanical expansion/construction joint to function and fulfill the purpose it was designed for: MOVEMENT. Testing of ULTRA BLOCK for use in expansion/construction joints was conducted at Underwriters Laboratories, Northbrook, Illinois. Tests were performed to the full-scale, 180 sf surface area, and each joint tested was 12 ft. long. Our testing also included the hose stream portion. The full scale testing earned us classifications by UL for use in horizontal and vertical joints plus compliance with all major codes in the United States. Seismic testing of ULTRA BLOCK systems was performed by the University of California-San Diego. The seismic earthquake simulation test was a joint project between the US and Japan. ULTRA BLOCK performed perfectly under the most severe conditions. Specification Compliance: ULTRA BLOCK Systems comply with and/or have been tested under the following standards and building codes: UBC Uniform Building Code BOCA Building Officials and Code Administrators International SBCCI Southern Building Code Congress International City of Los Angeles Building Code UL 2079 UL Standard for Safety Tests for Fire Resistance of Building Joint Systems UL UL Standard for Safety Fire Tests of Building Construction and Materials UL 1479 UL Standard for Safety Fire Test of Through Penetration Firestops UL 723 UL Standard for Safety Test for Surface Burning Characteristics of Building Materials ASTM E119 Method for Fire Tests of Building Construction and Materials ASTM E814 Methods for Fire Tests of Through Penetration Fire Stops ASTM E84 Test Method for Surface Burning Characteristics of Building Materials ASTM E136 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750ºC ASTM E90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions ASTM E1399 Test Method of Cyclic Movement and Measuring the Minimum and Maximum Joint Widths of Architectural Joint System ASTM C719 Test Method for Adhesion and Cohesion of Elastomeric Joint Sealants Under Cyclic Movement ASTM C920 Specification for Elastomeric Joint Sealants NFPA 251 Fire Test of Building Construction Materials NFPA 255 Burning Character of Building Materials WARRANTY Unless otherwise agreed to in writing, product is sold without warranty. 7.4

245 Standard UL Design Numbers for ULTRA BLOCK Ultra Block 1-4 Floor 2-Hour rated UL Design Number FF-S

246

247 Reflex Floor Series/MoDEl RFX (FlooR) Product Description: The C/S Reflex (RFX) is designed to be an installer friendly fire barrier system for 1-4 nominal floor expansion joints. Reflex has been tested and proven to provide up to 2-hour fire endurance rating, minimize smoke passage and accommodate dynamic movement without degradation of the material. The barriers have been tested and are listed with Underwriters Laboratories and will meet most current building codes and testing criteria. Basic Uses For 1-4 nominal, horizontal rated expansion joints for buildings and parking decks. Maximum 2- hour rating. Technical Data PERFORMANCE STANDARDS: UL-2079, ASTM E-1966, ASTM E1399, ASTM E-119 CODE COMPLIANCE: UBC, SBC, BOCA, IBC MATERIAL: Reflex Insulation Proprietary fiberglass matrix with scrim cloth lining. S/S Heat 2-mil stainless steel foil with rolled edges. Ceramic Blanket ½ x 8# density ceramic blanket. (Required with RFX-4F only.) Precautions Refer to Material Safety Data Sheet for detailed health and safety information prior to use. Warranty C/S warrants that its products are manufactured free of defects and conform to the technical data listed. Under this warranty, we will replace (at no charge) any material proven defective when applied in accordance with our written instructions for applications recommended by us as suitable for subject products. C/S shall not be liable for any injury, loss or damage, direct or consequential, arising out of the use of the product. Standard UL Design Numbers for Reflex reflex 1 Floor 2-Hour rated reflex 2 Floor 2-Hour rated reflex 2 Floor 3-Hour rated reflex 3 Floor 2-Hour rated reflex 4 Floor 2-Hour rated UL Design Number FF-D-0044 FF-D-0045 FF-D-0046 FF-D-1055 FF-D-1056 To download detail, specs & photos visit For technical and design assistance call

248

249 Reflex Wall Series/MoDEl RFX (WAll) Product Description: The C/S Reflex (RFX) is designed to be an installer friendly fire barrier system for 1-4 nominal wall expansion joints. Reflex has been tested and proven to provide up to 2-hour fire endurance rating, minimize smoke passage and accommodate dynamic movement without degradation of the material. The barriers have been tested and are listed with Underwriters Laboratories and will meet most current building codes and testing criteria. Basic Uses For 1-4 nominal, vertical rated expansion joints for buildings and parking decks. Maximum 2-hour rating. Technical Data PERFORMANCE STANDARDS: UL-2079, ASTM E-1966, ASTM E1399, ASTM E-119 CODE COMPLIANCE: UBC, SBC, BOCA, IBC MATERIAL: Reflex Insulation Proprietary fiberglass matrix with scrim cloth lining. Precautions Refer to Material Safety Data Sheet for detailed health and safety information prior to use. Warranty C/S warrants that its products are manufactured free of defects and conform to the technical data listed. Under this warranty, we will replace (at no charge) any material proven defective when applied in accordance with our written instructions for applications recommended by us as suitable for subject products. C/S shall not be liable for any injury, loss or damage, direct or consequential, arising out of the use of the product. Standard UL Design Numbers for Reflex reflex 1 Wall 2-Hour rated (Gyp. Board) reflex 1 Wall 2-Hour rated (cmu) reflex 1 Wall 1-Hour rated (Gyp. Board) reflex 1 Wall 1-Hour rated (cmu) reflex 2 Wall 2-Hour rated (Gyp. Board) reflex 2 Wall 2-Hour rated (cmu) reflex 2 Wall 1-Hour rated (Gyp. Board) reflex 2 Wall 1-Hour rated (cmu) reflex 3 Wall 2-Hour rated (Gyp. Board) reflex 3 Wall 2-Hour rated (cmu) reflex 4 Wall 2-Hour rated (Gyp. Board) reflex 4 Wall 2-Hour rated (cmu) UL Design Number WW-D-0048 WW-D-0049 WW-D-0059 WW-D-0060 WW-D-0050 WW-D-0051 WW-D-0061 WW-D-0062 WW-D-1067 WW-D-1068 WW-D-1071 WW-D-1072 To download detail, specs & photos visit For technical and design assistance call

250

251 Monoflex Series Product Description: The C/S Monoflex fire barrier is blanket type barrier designed for 1-20 nominal floor and wall expansion joints. Monoflex has been tested and proven to provide up to 2-hour fire endurance rating, minimize smoke passage and accommodate dynamic movement without degradation of the material. The barriers have been tested and are listed with Underwriters Laboratories and will meet most current building codes and testing criteria. Basic Uses For 1-20 nominal, horizontal and vertical rated expansion joints for buildings and parking decks. Maximum 2-hour rating. Technical Data PERFORMANCE STANDARDS: UL-2079, ASTM E-1966, ASTM E1399, ASTM E-119 CODE COMPLIANCE: UBC, SBC, BOCA, IBC Precautions Refer to Material Safety Data Sheet for detailed health and safety information prior to use. Warranty C/S warrants that its products are manufactured free of defects and conform to the technical data listed. Under this warranty, we will replace (at no charge) any material proven defective when applied in accordance with our written instructions for applications recommended by us as suitable for subject products. C/S shall not be liable for any injury, loss or damage, direct or consequential, arising out of the use of the product. Standard UL Design Numbers for Monoflex Monoflex 1-2 Floor 2-Hour rated Monoflex 3-6 Floor 2-Hour rated Monoflex 8-12 Floor 2-Hour rated Monoflex Floor 2-Hour rated Monoflex 1-2 Floor towall 2-Hour rated Monoflex 3-6 Floor towall 2-Hour rated Monoflex 8-12 Floor towall 2-Hour rated Monoflex Floor towall 2-Hour rated Monoflex 1-2 Wall 1 & 2-Hour rated (Gyp. Board) Monoflex 1-2 Wall 2-Hour rated (cmu) Monoflex 3-6 Wall 1 & 2-Hour rated (Gyp. Board) Monoflex 3-6 Wall 2-Hour rated (cmu) Monoflex 8-12 Wall 1 & 2-Hour rated (Gyp. Board) Monoflex 8-12 Wall 2-Hour rated (cmu) UL Design Number FF-D-0079 FF-D-1094 FF-D-2017 FW-D-3011 FW-D-0056 FW-D-1078 FW-D-2006 FF-D-3006 WW-D-0097 WW-D-0098 WW-D-1085 WW-D-1086 WW-D-2018 WW-D-2019 To download detail, specs & photos visit For technical and design assistance call

252

253 Multiflex Series Product Description: The C/S Multiflex fire barrier is blanket type barrier designed for 1-12 nominal floor and wall expansion joints. Multiflex has been tested and proven to provide up to 2-hour fire endurance rating, minimize smoke passage and accommodate dynamic movement without degradation of the material. The barriers have been tested and are listed with Underwriters Laboratories and will meet most current building codes and testing criteria. Basic Uses For 1-12 nominal, horizontal and vertical rated expansion joints for buildings and parking decks. Maximum 2-hour rating. Technical Data PERFORMANCE STANDARDS: UL-2079, ASTM E-1966, ASTM E1399, ASTM E-119 CODE COMPLIANCE: UBC, SBC, BOCA, IBC Precautions Refer to Material Safety Data Sheet for detailed health and safety information prior to use. Warranty C/S warrants that its products are manufactured free of defects and conform to the technical data listed. Under this warranty, we will replace (at no charge) any material proven defective when applied in accordance with our written instructions for applications recommended by us as suitable for subject products. C/S shall not be liable for any injury, loss or damage, direct or consequential, arising out of the use of the product. Standard UL Design Numbers for Multiflex Multiflex 1-2 Floor 2-Hour rated Multiflex 3-6 Floor 2-Hour rated Multiflex 8-12 Floor 2-Hour rated Multiflex Floor 2-Hour rated Multiflex 1-2 Floor towall 2-Hour rated Multiflex 3-6 Floor towall 2-Hour rated Multiflex 8-12 Floor towall 2-Hour rated Multiflex Floor towall 2-Hour rated Multiflex 1-2 Wall 1 & 2-Hour rated (Gyp. Board) Multiflex 1-2 Wall 2-Hour rated (cmu) Multiflex 3-6 Wall 1 & 2-Hour rated (Gyp. Board) Multiflex 3-6 Wall 2-Hour rated (cmu) Multiflex 8-12 Wall 1 & 2-Hour rated (Gyp. Board) Multiflex 8-12 Wall 2-Hour rated (cmu) UL Design Number FF-D-0051 FF-D-1066 FF-D-2009 FW-D-3004 FW-D-0040 FW-D-1062 FW-D-2004 FF-D-3008 WW-D-0052 WW-D-0053 WW-D-1056 WW-D-1057 WW-D-2011 WW-D-2012 To download detail, specs & photos visit For technical and design assistance call

254

255 FB-97 Series Product Description: The C/S FB-97 fire barrier is multi-layer barrier designed for 5-36 nominal floor and wall expansion joints. FB-97 has been tested and proven to provide up to 2-hour fire endurance rating, minimize smoke passage and accommodate dynamic movement without degradation of the material. The barriers have been tested and are listed with Underwriters Laboratories and meet most current building codes and testing criteria. Basic Uses For 5-36 nominal, horizontal and vertical rated expansion joints for buildings and parking decks. Maximum 2-hour rating. Technical Data PERFORMANCE STANDARDS: UL-2079, ASTM E-1966, ASTM E1399, ASTM E-119 CODE COMPLIANCE: UBC, SBC, BOCA, IBC Standard Finish Mill finish. Aluminum surfaces in contact with concrete will be protected with a minimum 2 mil coating of a heavy metal free high solids primer. Precautions Refer to Material Safety Data Sheet for detailed health and safety information prior to use. Warranty C/S warrants that its products are manufactured free of defects and conform to the technical data listed. Under this warranty, we will replace (at no charge) any material proven defective when applied in accordance with our written instructions for applications recommended by us as suitable for subject products. C/S shall not be liable for any injury, loss or damage, direct or consequential, arising out of the use of the product. Standard UL Design Numbers for FB-97 FB " Floor 2-Hour rated, 80% compression, 95% Extension FB " Floor 2-Hour rated, 50% compression or Extension FB " Floor 2-Hour rated, 80% compression, 95% Extension FB " Floor 2-Hour rated, 50% compression or Extension FB " Floor 2-Hour rated, 80% compression, 95% Extension FB " Wall 2-Hour rated, 80% compression, 90% Extension (Gyp.) FB " Wall 2-Hour rated, 80% compression, 90% Extension (cmu) FB " Wall 2-Hour rated, 80% compression, 90% Extension (Gyp.) FB " Wall 2-Hour rated, 80% compression, 90% Extension (cmu) FB " Wall 2-Hour rated, 80% compression, 90% Extension (Gyp.) FB " Wall 2-Hour rated, 80% compression, 90% Extension (cmu) FBcW 12-17" chase Wall 2-Hour rated, 50% compression, 100% Extension FBcW 18-24" chase Wall 2-Hour rated, 80% compression, 100% Extension FBcW 25-36" chase Wall 2-Hour rated, 80% compression, 100% Extension UL Design Number FF-D-2004 FF-D-3005 FF-D-3006 FF-D-4001 FF-D-4002 WW-D-2007 WW-D-2008 WW-D-3007 WW-D-3008 WW-D-4001 WW-D-4002 WW-D-2010 WW-D-3009 WW-D-4003 To download detail, specs & photos visit For technical and design assistance call

256

257 Support Information Expansion Joint Covers FAQ Q. What are the standard gasket colors and are custom colors available? Q. What are the most important criteria when selecting a joint cover/system? Q. How do I maintain the integrity of a fire rated element such as a floor or firewall? Q. Are all testing agencies equal? Q. What's the significance of ASTM-E 1399? Q. Is it important for me to work out all the transitions between adjacent cover systems? Q. What is the most common cause of failure of joint cover systems? Q. What are the standard gasket colors and are custom colors available? A. There are four standard gasket colors that include black, white, gray and greige. Custom colors are also available although minimum quantities and extra charges may apply. Q. What are the most important criteria when selecting a joint cover/system? A. When selecting a joint cover system, you will need to carefully consider the following: I. Structural joint opening: This is nearly always established by the structural engineer and determines the type of cover needed, i.e., thermal or seismic movement. Note: The term "seismic" is only a factor of joint width, not function. Some of our 3 and 4 covers are not labeled seismic yet can be used if the joint opening is only 3 or 4, even in "seismic" design schemes. II. Anticipated movement: Again, determined by the structural engineer and normally specified as plus or minus 'x' when 'x' may be a dimension, i.e., 1, or a percentage of joint opening, i.e., 50%. III. Type of building: The anticipated use of the building will help determine the type of cover system chosen. For example, a hospital will require covers that are easy to keep clean and also have a flush top surface since wheeled equipment is an aspect of normal building occupation. This would lead to the selection of a gasketed cover system. We recommend that the selection process start with the choice of floor cover as this is affected the most by such building usage. Wall covers are then simply matched to the floor cover selected. CAUTION: Rolling loads can have a significant impact on the function of a cover system. If heavy-wheeled equipment is expected, such as in airports, covers labeled "heavy-duty" should be selected. IV. Aesthetic considerations: Once the above criteria are established, the final piece of the puzzle is appearance. Historically, seismic joint covers have been known to ruin even the most carefully designed interior finishes scheme. Fortunately, C/S has developed a complete range of covers with reveals that help conceal most of the cover plate regardless of the joints. Q. How do I maintain the integrity of a fire-rated element such as a floor or firewall? A. Every cover system in the C/S portfolio has a fire barrier assembly designed to work with it. These fire barriers are tested at UL to ensure full code compliance. Assemblies are available in standard 2-hour ratings but also 1,3 and even 4-hour ratings in some cases. Due to the high cost of UL tests, not all structural configurations have been tested. Some discretion may be needed to determine if a standard configuration applies in the case of a non-standard application. If in doubt, call the supplier and ask for additional testing to support your design. UL will normally accept small scale testing as an extension of an existing full-scale test and give it a rating. 8.1

258 Q. Are all testing agencies equal? A. Definitely not! Even though other agencies test to the same ASTM standards, they don't all have follow up and labeling services. Underwriter's Laboratories has a factory labeling and quality inspection that guarantees that the product installed in your building is exactly the same as the product tested successfully in the lab. It is important to specify UL tested and labeled to ensure peace of mind for your client. Q. What's the significance of ASTM-E 1399? A. ASTM-E 1399 is a relatively new code that stipulates that all expansion and seismic joint cover systems be tested through 500 movement cycles and remain functional. Since these covers are intended to move in this way, specifying ASTM-E 1399 is simply a quality assurance for your client. In the case of fire barrier testing, UL 2079 stipulates that the assembly must be cycled 500 times prior to testing. A critical quality assurance factor ensuring peace of mind for your client. Q. Is it important for me to work out all the transitions between adjacent cover systems? A. It is very important that these transition details are worked out thoroughly since bad transitions can ruin even the best joint cover schemes. However, any competent joint manufacturer should be willing to assist you with these details during the de sign phase of the project. CAUTION: Transitions in exterior covers, particularly between roof and wall covers, are critical to the water tightness of the exterior envelope. Q. What is the most common cause of failure of joint cover systems? A. The most common cause is improper selection of the type of cover. In particular, heavy-rolling loads can destroy even the best floor covers if they aren't designed to take high loading. CAUTION: There is another element that's critical to the successful function of the floor covers, and that's the use of shims during installation. It is common practice to oversize block-outs in the concrete and then use shims to level the floor cover. This is OK provided the contractor pours a leveling grout between shims to ensure a continuous base for the floor cover. Most often the covers are bolted down through the shims and the block-out filled with grout/lean concrete. In this case, it's unlikely that the grout will find its way consistently beneath the frames resulting in poorly bedded floor covers. The use of rolling equipment will cause rocking or bouncing of the frame and eventually lead to failure of the grout pocket and cracking of the floor finish. It is imperative that you specify that, if shims are to be used in the installation process, the contractor ensures that there is a continuous support bed beneath the side frames of the floor cover. We would go further and suggest these frames be inspected prior to filling the block-out with grout. 8.2 To download detail, specs & photos visit For technical and design assistance call

259 Standard Gasket Colors Black White Gray Greige Powder Coat Abrasive Colors (Aluminum Covers Only) Platinum Kynar 500 and Hylar 5000 (Aluminum Covers Only) *Premium (extra cost) color. #521 Bone White #519 Sandstone #563 Seawolf Gray #580 Interstate Green* #562 Phantom Gray #549 Charcoal #548 Light Bronze #585 Arabian Blue* #559 Mushroom #516 Spanish White #543 Medium Bronze #518 Colonial White* #560 Onyx Gray #572 Sand Beige #546 Dark Bronze #581 Forge Red* #512 Black #532 Terra Cotta #537 Cordovan Brown #584 Banner Red* 8.3

260 VF Model colors *Only available on the VF models. Precast White Limestone Gray Black Bronze Sandstone Adobe Tan Dusty Rose Rustic Brick Duranodic Finishes (Aluminum Covers Only) Blue Spruce *Finishes available on select C/S products. Charcoal Natural Stone Clear Light Bronze* Medium Bronze* Dark Bronze* Black* 8.4 To download detail, specs & photos visit For technical and design assistance call

261 Operations and Maintenance The Expansion Joint Cover material is comprised of a thermal plastic rubber and aluminum. General care and cleaning is achieved using a commercial grade cleaner and water. In no instance should an acid based product be used to clean the aluminum or rubber surfaces. For heavy cleaning of scuffmarks, a commercial grade spray cleaner can be used for spot cleaning and touch-up. (IE; Fantastik, 409, ETC). For unexposed Expansion Joint Covers there is no cleaning required to maintain performance. Any roof Expansion Joint Covers can be cleaned with a mild soap and water. Again, no acid based products should be used. Any additional information concerning our products can be received through our representative, or by calling Construction Specialties, Inc. directly at Warranty CONSTRUCTION SPECIALTIES, INC. (the Company) warrants to its purchasers that the EXPANSION JOINT COVERS sold by it shall be free of defects in materials or workmanship, and will meet the design criteria noted in our catalogs when properly applied and installed. If, in the sole opinion of the Company, a product covered by this warranty is defective, this warranty is limited to the repair and/or replacement of the product. This limited warranty shall extend for a period of five (5) years following the date of substantial completion: The Company shall not be responsible or liable for consequential or incidental damages resulting from any defect in the product. In the event of a defect, the Company shall repair and/or replace the defective material provided the following conditions have been satisfied: 1. You shall notify the Company, in writing, that the product has become defective, stating the nature of the defects within the warranty period; and 2. You shall permit the Company, its agents, and employees access to examine the product after notification so that the cause of the problem can be determined and repairs or replacements made. EXCEPTIONS Excluded from the terms of this limited warranty are the following: 1. The Company shall not be liable and responsible for consequential or incidental damages. 2. The Company shall not be liable for damages caused by unusual, extraordinary or unforeseen conditions; and 3. Any repair work or alteration of the product not done under the supervision, or subject to the approval of the Company, shall void any liability under the limited warranty. CONSTRUCTION SPECIALTIES, INC. MAKES NO WARRANTIES WHICH EXTEND BEYOND THE FACE HEREOF AND EXCEPT AS PROVIDED ABOVE CONSTRUCTION SPECIALTIES, INC. MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING (WITHOUT LIMITATION) WARRANTIES OF FITNESS OR MERCHANTABILITY, WITH RESPECT TO THE PRODUCTS AND CONSTRUCTION SPECIALTIES, INC. SHALL HAVE NO OTHER LIABILITY WITH RESPECT THERETO. 8.5

262 Expansion Control PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section SUMMARY A. This Section includes the following: 1. Architectural joint systems for building interiors. (delete if not required) 2. Architectural joint systems for building exteriors. (delete if not required) 3. Architectural joint systems for open-air structures. (delete if not required) B. Related Sections include the following: 1. Division 03 Section "Cast-in-Place Concrete" for cast-in architectural-joint-system frames furnished, but not installed, in this Section. 2. Division 04 Section "Unit Masonry" for masonry wall joint systems. 3. Division 07 Section "Sheet Metal Roofing" for sheet metal roof joint systems. 4. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal wall joint systems. 5. Division 07 Section "Fire-Resistive Joint Systems" for liquid-applied joint sealants in fire-resistive building joints. 6. Division 07 Section "Joint Sealants" for liquid-applied joint sealants DEFINITIONS A. Maximum Joint Width: Widest linear gap a joint system tolerates and in which it performs its designed function without damaging its functional capabilities. B. Minimum Joint Width: Narrowest linear gap a joint system tolerates and in which it performs its designed function without damaging its functional capabilities. C. Movement Capability: Value obtained from the difference between widest and narrowest widths of a joint. D. Nominal Joint Width: The width of the linear opening specified in practice and in which the joint system is installed SUBMITTALS A. Shop Drawings: Provide the following for each joint system specified and obtain approval prior to fabrication and shipment of materials to the job site: 1. Placement Drawings: Include line diagrams showing plans, elevations, sections, details, splices, blockout requirement, entire route of each joint system, and attachments to other work. Where joint systems change planes, provide isometric or clearly detailed drawing depicting how components interconnect. B. Product Data: Submit copies of manufacturer s latest published literature for materials specified herein for approval, and obtain approval before materials are fabricated and delivered to the site. Data to clearly indicate movement capability of cover assemblies and suitability of material used in exterior seal for UV exposure. C. Samples for Initial Selection: For each type of joint system indicated. 1. Include manufacturer's color charts showing the standard range of colors and finishes available for each exposed metal and elastomeric seal material. D. Certificates Material test reports from qualified independent testing laboratory indicating and interpreting test results relative to compliance of fire-rated expansion joint assemblies with requirements indicated. 8.6 To download detail, specs & photos visit For technical and design assistance call

263 1.05 QUALITY ASSURANCE A. Installer Qualifications: Approved by manufacturer. B. Source Limitations: Obtain all architectural joint systems through one source from a single manufacturer. C. Product Options: Drawings indicate size, profiles, and dimensional requirements of architectural joint systems and are based on the specific systems indicated. Refer to Division 01 Section "Product Requirements." 1. Do not modify intended aesthetic effects, as judged solely by Architect, except with Architect's approval. If modifications are proposed, submit comprehensive explanatory data to Architect for review. D. Loading Characteristics: Standard loading refers to covers that are capable of withstanding up to 500 lb. point loads. Heavy-duty refers to covers that are capable of withstanding up to 2000 lb. point loads. E. Fire-Test-Response Characteristics: Where indicated, provide architectural joint system and fire-barrier assemblies identical to those of assemblies tested for fire resistance per UL 2079 and/or ASTM E 1966 by a testing and inspecting agency acceptable to authorities having jurisdiction. Fire rating not less than the rating of adjacent construction. F. Manufacturer to provide 5 year warranty for all joint covers COORDINATION A. Coordinate installation of exterior wall joint systems with roof expansion assemblies to ensure that wall transitions are watertight. PART 2 - PRODUCTS 2.01 MATERIALS A. Aluminum: ASTM B 221, Alloy 6063-T6, 6063-T5, 6063-T52, 6061-T5, 6061-T6, 6061-T51, 6105-T5, 6105-T6, 6005-T5, 6005A-T5 or 6005A-T61 for extrusions; ASTM B 209, Alloy 6061-T6, 3003-H14, 5005-H34 for sheet and plate. 1. Apply manufacturer's standard protective coating on aluminum surfaces to be placed in contact with cementitious materials. 2. Mill Finish: AA-M10 (Mechanical Finish: as fabricated, unspecified). 3. Class II, Clear Anodic Finish: AA-M12C22A31 (Mechanical Finish: nonspecular as fabricated; Chemical Finish: etched, medium matte; Anodic Coating: Architectural Class II, clear coating mm or thicker) complying with AAMA Class II, Color Anodic Finish: AA-M12C22A32/A34 (Mechanical Finish: nonspecular as fabricated; Chemical Finish: etched, medium matte; Anodic Coating: Architectural Class II, integrally colored or electrolytically deposited color coating mm or thicker) complying with AAMA High-Performance Organic Finish (Two-Coat Fluoropolymer): AA-C12C40R1x (Chemical Finish: cleaned with inhibited chemicals; Chemical Finish: conversion coating; Organic Coating: manufacturer's standard two-coat, thermocured system consisting of specially formulated inhibitive primer and fluoropolymer color top coat containing not less than 70 percent polyvinylidene fluoride resin by weight). Prepare, pre treat, and apply coating to exposed metal surfaces to comply with AAMA 2604 and with coating and resin manufacturers' written instructions. B. Stainless Steel: ASTM A 666, Type 304 for plates, sheet, and strips. 1. Finish: No.4, directional satin. a. Grind and polish surfaces to produce uniform, directionally textured, polished finish indicated, free of cross scratches. Run grain with long dimension of each piece. b. When polishing is completed, passivate and rinse surfaces. Remove embedded foreign matter and leave surfaces chemically clean. C. Brass: ASTM B 36/B 36M, UNS Alloy C26000 for half hard sheet and coil. D. Bronze: ASTM B 455, Alloy C38500 for extrusions; Alloy C28000 Muntz Metal for plates. 8.7

264 E. Elastomeric Seals: Preformed elastomeric membranes or extrusions to be installed in metal frames. F. Compression Seals: ASTM D2000; preformed rectangular elastomeric extrusions having internal baffle system and designed to function under compression. G. Fire Barriers: Any material or material combination, when fire tested after cycling, designated to resist the passage of flame and hot gases through a movement joint and to meet performance criteria for required rating period. H. Moisture Barrier: 7-ply laminate reinforced Polyethylene. I. Accessories: Manufacturer's standard anchors, clips, fasteners, set screws, spacers, and other accessories compatible with material in contact, as indicated or required for complete installations ARCHITECTURAL JOINT SYSTEMS, GENERAL A. General: Provide architectural joint systems of design, basic profile, materials, and operation indicated. Provide units with capability to accommodate variations in adjacent surfaces. B. Design architectural joint systems for the following size and movement characteristics: 1. Nominal Joint Width: [As indicated on Drawings] [As scheduled] <Insert width>. 2. Maximum Joint Width: [As indicated on Drawings] [As scheduled] <Insert width>. 3. Minimum Joint Width: [As indicated on Drawings] [As scheduled] <Insert width>. 4. Lateral Shear Movement Capability: [As indicated on Drawings] [As scheduled] <Insert movement capability> ARCHITECTURAL JOINT SYSTEMS FOR BUILDING INTERIORS A. Construction Specialties, Inc., 6696 State Route 405 Highway, Muncy, PA, shall manufacture expansion joint cover assemblies specified herein and indicated on the drawings. Other manufacturers may be accepted as substitutions only if the manufacturer can demonstrate product compliance with the requirements of the contract documents. Substitution requests must be reviewed prior to bid and must include the following information: 1. Details. 2. ASTM- E1399 test reports. 3. Mock-ups. 4. Reference list of projects with similar products as those specified herein. 5. Written 5 year warranty. B. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GFT, GFT-M 2. Type: Elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Attachment Method: Mechanical anchors. 4. Load Capacity: Standard duty. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 6. Moisture Barrier: Manufacturer's standard. (delete if not required) C. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GFS, GFST, GFPS 8.8 To download detail, specs & photos visit For technical and design assistance call

265 2. Type: Surface mounted. 3. Type: Elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) D. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GTR, GTR-M DGTR, DGTR-M 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/8 inch. b. Cover plate held in place with turnbar. Spring clips do not consistently comply with ASTM-E1399 testing and are not acceptable. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) E. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GTR-D, GTR-DM DGTR-D, DGTR-DM 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Recessed to accept field-applied flexible finish materials. a. Recess Depth: 3/8 inch. b. Cover plate held in place with turnbar. Spring clips do not consistently comply with ASTM-E1399 testing and are not acceptable. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) F. Floor-to-Floor Joint Systems: (delete if not required) 8.9

266 1. Basis-of-Design Product: Construction Specialties, Inc. model GTP, GTP-M, DGTP, DGTP-M 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Plain. a. Cover plate held in place with turnbar. Spring clips do not consistently comply with ASTM-E1399 testing and are not acceptable. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) G. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GTP-HD, DGTP-HD 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1)Color: As selected by Architect from manufacturer's standard range. 2)Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Plain. a. Cover plate held in place with turnbar. Spring clips do not consistently comply with ASTM-E1399 testing and are not acceptable. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Heavy duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) H. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SGP 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) I. Floor-to-Floor Joint Systems: (delete if not required) 8.10 To download detail, specs & photos visit For technical and design assistance call

267 1. Basis-of-Design Product: Construction Specialties, Inc. model SGR 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/8 inch. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) J. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model ALR, ALR-M 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/8 inch. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Standard duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8. Moisture Barrier: Manufacturer's standard. (delete if not required) K. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model ALS, ALS-M 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Serrated. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Standard duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8. Moisture Barrier: Manufacturer's standard. (delete if not required) L. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model AL-HD, AL-HDM 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Serrated. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Heavy duty. 8.11

268 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8. Moisture Barrier: Manufacturer's standard. (delete if not required) M. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FYW 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/8 inch. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Standard duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8. Moisture Barrier: Manufacturer's standard. (delete if not required) N. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FYW-D 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/4 inch. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Standard duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8. Moisture Barrier: Manufacturer's standard. (delete if not required) O. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model PC 2. Type: Glide plate. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) P. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SJP, SJP-M, SJPF, SJPF-M 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Plate Design: Plain 8.12 To download detail, specs & photos visit For technical and design assistance call

269 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) Q. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SJ-HD, SJ-HDM 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Plate Design: Plain 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Heavy duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) R. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model APF 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Plate Design: Serrated/Striated 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Heavy duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) S. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SSR 2. Type: Pan. a. Exposed Metal: Aluminum. 1) Finish: Mill. 2) Center pan that receives finish material must be extruded. Pans formed from sheet or plate products are not acceptable. 3. Cover-Plate Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1 minimum. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) T. Floor-to-Floor Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SSRH 2. Type: Pan. a. Exposed Metal: Aluminum. 1) Finish: Mill. 2) Center pan that receives finish material must be extruded. Pans formed from sheet or plate products are not acceptable. 8.13

270 3. Cover-Plate Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1 minimum. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) U. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GFTW 2. Type: Elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Attachment Method: Mechanical anchors. 4. Load Capacity: Standard duty. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 6. Moisture Barrier: Manufacturer's standard. (delete if not required) V. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GFSW, GFSTW, GFPSW 2. Type: Surface mounted. 3. Type: Elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) W. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GTRW, DGTRW 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/8 inch. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) 8.14 To download detail, specs & photos visit For technical and design assistance call

271 X. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GTRW-D, DGTRW-D 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Recessed to accept field-applied flexible finish materials. a. Recess Depth: 3/8 inch. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) Y. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GTPW, DGTPW 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) Z. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GTPW-HD, DGTPW-HD 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Heavy duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) AA. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SGPW 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. 8.15

272 b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) BB. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SGRW 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt. 3. Cover-Plate Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/8 inch. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) CC. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model ALRW 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/8 inch. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Standard duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8. Moisture Barrier: Manufacturer's standard. (delete if not required) DD. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model ALSW 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Serrated. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Standard duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8.16 To download detail, specs & photos visit For technical and design assistance call

273 8. Moisture Barrier: Manufacturer's standard. (delete if not required) EE. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model ALW-HD 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Serrated. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Heavy duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8. Moisture Barrier: Manufacturer's standard. (delete if not required) FF. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FYWW 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/8 inch. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Standard duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8. Moisture Barrier: Manufacturer's standard. (delete if not required) GG. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FYWW-D 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Side Frame Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1/4 inch. 4. Cover Plate Design: Plain 5. Attachment Method: Mechanical anchors. 6. Load Capacity: Standard duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8. Moisture Barrier: Manufacturer's standard. (delete if not required) HH. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model PCW 2. Type: Glide plate. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. 8.17

274 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) II. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SJPW, SJPFW 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Plate Design: Plain 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) JJ. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SJW-HD 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Plate Design: Plain 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Heavy duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) KK. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model APFW 2. Type: Cover plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover Plate Design: Serrated/Striated 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Heavy duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) LL. Floor-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SSRW 2. Type: Pan. a. Exposed Metal: Aluminum. 1) Finish: Mill. 2) Center pan that receives finish material must be extruded. Pans formed from sheet or plate products are not acceptable To download detail, specs & photos visit For technical and design assistance call

275 3. Cover-Plate Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1 minimum. 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Heavy duty. 6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 7. Moisture Barrier: Manufacturer's standard. (delete if not required) MM. Wall-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FWF, FWF-M 2. Type: Flat seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) NN. Wall-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FWS, FWS-M 2. Type: Accordion substitution of flat seal profiles is not acceptable. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) OO. Wall-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GFS-W 2. Type: Surface mounted. 3. Type: Elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 4. Attachment Method: Mechanical anchors. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 6. Moisture Barrier: Manufacturer's standard. (delete if not required) PP. Wall-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GTW 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of 8.19

276 adjacent construction. (delete if not required) 6. Moisture Barrier: Manufacturer's standard. (delete if not required) QQ. Wall-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SGW 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 6. Moisture Barrier: Manufacturer's standard. (delete if not required) RR. Wall-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model LAF, LAS 2. Type: Vertical cover panel a. Exposed Metal: Aluminum. 1) Panel Finish: Factory applied clear epoxy primer and field applied paint or wall covering. 2) Frame Finish: Class II, clear anodic. 3. Panels held in place with hook and loop attachment system and incorporate a secondary system comprised of a pre-tensioned shock cord. 4. Covers that utilize turnbars or other similar centering devices limit lateral shear movement and are not acceptable. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 6. Moisture Barrier: Manufacturer's standard. (delete if not required) SS. Wall-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model AFW, ASM 2. Type: Snap-on cover. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 4. Moisture Barrier: Manufacturer's standard. (delete if not required) TT. Wall-to-Wall Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SFW 2. Type: Vertical cover plate. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 4. Moisture Barrier: Manufacturer's standard. (delete if not required) UU. Wall Corner Joint Systems: (delete if not required) 8.20 To download detail, specs & photos visit For technical and design assistance call

277 1. Basis-of-Design Product: Construction Specialties, Inc. model FWFC, FWFC-M 2. Type: Flat seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) VV. Wall Corner Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FWSC, FWSC-M 2. Type: Accordion substitution of flat seal profiles is not acceptable. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) WW. Wall Corner Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model GTWC 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 6. Moisture Barrier: Manufacturer's standard. (delete if not required) XX. Wall Corner Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SGWC 2. Type: Dual elastomeric seal. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. b. Seal Material: CS Thermoplastic Rubber (TPR). 1) Color: As selected by Architect from manufacturer's standard range. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 6. Moisture Barrier: Manufacturer's standard. (delete if not required) YY. Wall Corner Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model LAFC, LASC 2. Type: Vertical cover panel a. Exposed Metal: Aluminum. 1) Panel Finish: Factory applied clear epoxy primer and field applied paint or wall covering. 8.21

278 2) Frame Finish: Class II, clear anodic. 3. Panels held in place with hook and loop attachment system and incorporate a secondary system comprised of a pre-tensioned shock cord. 4. Covers that utilize turnbars or other similar centering devices limit lateral shear movement and are not acceptable. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 6. Moisture Barrier: Manufacturer's standard. (delete if not required) ZZ. Wall Corner Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model AFWC, ASMC 2. Type: Snap-on cover. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 4. Moisture Barrier: Manufacturer's standard. (delete if not required) AAA. Wall Corner Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SCW 2. Type: Vertical cover plate. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 4. Moisture Barrier: Manufacturer's standard. (delete if not required) BBB. Wall-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model HCW 2. Type: Accordion. a. Seal Material: PVC. 1) Color: White. CCC. Wall-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FCFC 2. Type: Flat seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range. DDD. Wall-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FCSC 2. Type: Accordion - substitution of flat seal profiles is not acceptable. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range To download detail, specs & photos visit For technical and design assistance call

279 EEE. Wall-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SGCC 2. Type: Dual reveal. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. FFF. Wall-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SCC 2. Type: Vertical cover plate. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. GGG. Wall-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model LAFC, LASC 2. Type: Cover panel a. Exposed Metal: Aluminum. 1) Panel Finish: Factory applied clear epoxy primer and field applied paint or wall covering. 2) Frame Finish: Class II, clear anodic. 3. Panels held in place with hook and loop attachment system and incorporate a secondary system comprised of a pre-tensioned shock cord. 4. Covers that utilize turnbars or other similar centering devices limit lateral shear movement and are not acceptable. HHH. Ceiling-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model HC 2. Type: Accordion. a. Seal Material: PVC. 1) Color: White. III. Ceiling-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FCF 2. Type: Flat seal. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range. JJJ. Ceiling-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model FCS 2. Type: Accordion - substitution of flat seal profiles is not acceptable. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range. 8.23

280 KKK. Ceiling-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SGC 2. Type: Dual reveal. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. 3. Cover-Plate Design: Plain. 4. Attachment Method: Mechanical anchors. LLL. Ceiling-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SFC 2. Type: Vertical cover plate. a. Exposed Metal: Aluminum. 3. Finish: Class II, clear anodic. MMM. Ceiling-to-Ceiling Joint Systems: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model LAF, LAS 2. Type: Cover panel a. Exposed Metal: Aluminum. 1) Panel Finish: Factory applied clear epoxy primer and field applied paint or wall covering. 2) Frame Finish: Class II, clear anodic. 3. Panels held in place with hook and loop attachment system and incorporate a secondary system comprised of a pre-tensioned shock cord. 4. Covers that utilize turnbars or other similar centering devices limit lateral shear movement and are not acceptable ARCHITECTURAL JOINT SYSTEMS FOR BUILDING EXTERIORS A. Construction Specialties, Inc., P.O. Box 380 Muncy, PA, shall manufacture expansion joint cover assemblies specified herein and indicated on the drawings. Other manufacturers may be accepted as substitutions only if the manufacturer can demonstrate product compliance with the requirements of the contract documents. Substitution requests must be reviewed prior to bid and must include the following information: 1. Details 2. ASTM- E1399 test reports 3. Mock-ups 4. Reference list of projects with similar products as those specified herein. 5. Written 5 year warranty B. Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SF 2. Type: Flat seal. a. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range. b. Secondary Seal: Manufacturer's standard extruded-elastomeric seal designed to prevent water and moisture infiltration. c. Pantograph Mechanism: Manufacturer's standard nylon pantographic wind-load support mechanism with stainless-steel fasteners for 12 joints and larger. 3. All miters and changes in direction to be factory fabricated, heat welded transitions. 4. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8.24 To download detail, specs & photos visit For technical and design assistance call

281 C. Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model SC 2. Type: Accordion - substitution of flat seal profiles is not acceptable. a. Seal Material: Santoprene. 1) Color: As selected by Architect from manufacturer's standard range. b. Secondary Seal: Manufacturer's standard extruded-elastomeric seal designed to prevent water and moisture infiltration. c. Pantograph Mechanism: Manufacturer's standard nylon pantographic wind-load support mechanism with stainless-steel fasteners for 12 joints and larger. 3. All miters and changes in direction to be factory fabricated, heat welded transitions. 4. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) D. Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model AFW-X 2. Type: Vertical cover-plate. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. b. Secondary Seal: 7-ply laminate reinforced Polyethylene. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) E. Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model ESW, ESC 2. Type: Vertical cover-plate. a. Exposed Metal: Aluminum. 1) Finish: Class II, clear anodic. b. Secondary Seal: 7-ply laminate reinforced Polyethylene. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) F. Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model RJT-V, RJTW-V, SRJ-V, SRJW-V 2. Type: Vertical cover-plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Secondary Seal: 7-ply laminate reinforced Polyethylene. 3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) G. Architectural Joint Systems for Exterior Walls: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model XLS, XLSC 2. Type: Pan. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Cover-Plate Design: Recessed to accept field-applied finish materials. a. Recess Depth: 1 minimum. 4. Attachment Method: Mechanical anchors with continuous hinge to support panel and permit full range of movements. Use of centering/tensioning bar assemblies will not be permitted. System to be secured in nominal position with minimum (2) 400# pull magnets per 10 assembly, and counterweighted to self-close following a seismic event. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 8.25

282 6. Moisture Barrier: 7-ply laminate reinforced Polyethylene. H. Architectural Joint Systems for Exterior Roofs: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model RJT, RJTW, SRJ, SRJW 2. Type: Vertical cover-plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. b. Secondary Seal: 7-ply laminate reinforced Polyethylene. 3. Cover plate thickness shall be determined by the performance requirements of the roof, but shall be no less than.090" thick. 4. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) I. Architectural Joint Systems for Exterior Roofs: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model BRJ, BRJW 2. Type: Bellows. a. Metal Flange: Galvanized. 1) Finish: Mill. b. Bellows: EPDM c. Secondary Seal: Manufacturer's standard. 3. Factory Fabricated Transitions: all end caps, transitions and miters to be factory fabricated to ensure weather integrity. Field fabrication is not acceptable. 4. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. (delete if not required) 2.05 ARCHITECTURAL JOINT SYSTEMS FOR OPEN-AIR STRUCTURES A. Construction Specialties, Inc., P.O. Box 380 Muncy, PA, shall manufacture expansion joint cover assemblies specified herein and indicated on the drawings. Other manufacturers may be accepted as substitutions only if the manufacturer can demonstrate product compliance with the requirements of the contract documents. Substitution requests must be reviewed prior to bid and must include the following information: 1. Details 2. ASTM- E1399 test reports 3. Mock-ups 4. Reference list of projects with similar products as those specified herein. 5. Written 5 year warranty B. Systems for Parking Structures: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model ZB, ZBW 2. Type: Epoxy-bonded seal. a. Seal Material: EPDM. 1) Color: Black. 3. Attachment Method: Compressed, epoxy adhered. 4. Load Capacity: Heavy duty. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. C. Joint Systems for Parking Structures: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model HB 8.26 To download detail, specs & photos visit For technical and design assistance call

283 2. Type: Compression seal. a. Seal Material: EPDM. 1) Color: Black. 3. Attachment Method: Compressed. 4. Load Capacity: Heavy duty. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent. D. Joint Systems for Parking Structures: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model CSAB 2. Type: Winged seal. a. Seal Material: Santoprene. 1) Color: Black. 3. Attachment Method: Mechanical anchors. 4. Load Capacity: Extra heavy duty to withstand AASHTO HS Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent. E. Joint Systems for Parking Structures: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model KB, KBW 2. Type: Metal plate. a. Exposed Metal: Aluminum. 1) Finish: Manufacturer's standard finish. 2) Finish: Mill. 3. Center plate design to allow for vertical movement without cantilevering end of plate into the air. 4. Turnbar and center plate to have direct positive engagement to protect center bolt from shearing forces. 5. Attachment Method: Mechanical anchors 6. Load Capacity: Heavy duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. 8. Gutter: 7-ply laminate reinforced Polyethylene. F. Joint Systems for Parking Structures: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model KB-HD, KBW-HD 2. Type: Metal plate. a. Exposed Metal: Aluminum. 1) Finish: Manufacturer's standard finish. 2) Finish: Mill. 3. Center plate design to allow for vertical movement without cantilevering end of plate into the air. 4. Turnbar and center plate to have direct positive engagement to protect center bolt from shearing forces. 5. Attachment Method: Mechanical anchors 6. Load Capacity: Extra heavy duty to withstand AASHTO HS Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. 8. Gutter: 7-ply laminate reinforced Polyethylene. G. Joint Systems for Parking Structures: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model KBC, KBCW 8.27

284 2. Type: Metal plate. a. Exposed Metal: Aluminum. 1) Finish: Manufacturer's standard finish. 2) Finish: Mill. 3. Center plate design to allow for vertical movement without cantilevering end of plate into the air. 4. Turnbar and center plate to have direct positive engagement to protect center bolt from shearing forces. 5. Attachment Method: Cast in 6. Load Capacity: Heavy duty. 7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. 8. Gutter: 7-ply laminate reinforced Polyethylene. H. Joint Systems for Parking Structures: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model KBC-HD, KBCW-HD 2. Type: Metal plate. a. Exposed Metal: Aluminum. 1) Finish: Manufacturer's standard finish. 2) Finish: Mill. 3. Center plate design to allow for vertical movement without cantilevering end of plate into the air. 4. Turnbar and center plate to have direct positive engagement to protect center bolt from shearing forces. 5. Attachment Method: Cast in 6. Load Capacity: Extra heavy duty to withstand AASHTO HS Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. 8. Gutter: 7-ply laminate reinforced Polyethylene. I. Joint Systems for Parking Structures: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model PTC, PTCW 2. Type: Metal plate. a. Exposed Metal: Aluminum. 1) Finish: Manufacturer's standard finish. 2) Finish: Mill. 3. Attachment Method: Mechanical anchors 4. Load Capacity: Extra heavy duty to withstand AASHTO HS Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent construction. 6. Gutter: 7-ply laminate reinforced Polyethylene. J. Joint Systems for Plaza Decks: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model PDA 2. Type: Metal plate. a. Exposed Metal: Aluminum. 1) Finish: Mill. 3. Type: Strip seal. a. Primary seal Material: Santoprene. 1) Color: Black. b. Wing seal Material: PVC 1) Color: Black 4. Attachment Method: Mechanical anchors. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent To download detail, specs & photos visit For technical and design assistance call

285 K. Joint Systems for Plaza Decks: (delete if not required) 1. Basis-of-Design Product: Construction Specialties, Inc. model PDS 2. Type: Metal plate. a. Exposed Metal: Stainless Steel. 1) Finish: No. 2B. 3. Type: Strip seal. a. Primary seal Material: Santoprene. 1) Color: Black. b. Wing seal Material: PVC 1) Color: Black 4. Attachment Method: Mechanical anchors. 5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of adjacent FINISHES A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes. B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping. C. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. PART 3 - EXECUTION 3.01 EXAMINATION A. Examine surfaces and blockouts where architectural joint systems will be installed for installation tolerances and other conditions affecting performance of work. 1. Proceed with installation only after unsatisfactory conditions have been corrected PREPARATION A. Prepare substrates according to architectural joint system manufacturer's written instructions. B. Repair concrete slabs and blockouts using manufacturer's recommended repair grout of compressive strength adequate for anticipated structural loadings. C. Coordinate and furnish anchorages, setting drawings, and instructions for installing joint systems. Provide fasteners of metal, type, and size to suit type of construction indicated and to provide for secure attachment of joint systems. D. Cast-In Frames: Coordinate and furnish frames to be cast into concrete INSTALLATION A. Comply with manufacturer's written instructions for storing, handling, and installing architectural joint assemblies and materials unless more stringent requirements are indicated. B. Metal Frames: Perform cutting, drilling, and fitting required to install joint systems. 8.29

286 1. Install in true alignment and proper relationship to joints and adjoining finished surfaces measured from established lines and levels. 2. Adjust for differences between actual structural gap and nominal design gap due to ambient temperature at time of installation. Notify Architect where discrepancies occur that will affect proper joint installation and performance. 3. Cut and fit ends to accommodate thermal expansion and contraction of metal without buckling of frames. 4. Locate in continuous contact with adjacent surfaces. 5. Standard-Duty Systems: Shim to level where required. Support underside of frames continuously to prevent vertical deflection when in service. 6. Heavy-Duty Systems: Repair or grout blockout as required for continuous frame support and to bring frame to proper level. Shimming is not allowed. 7. Locate anchors at interval recommended by manufacturer, but not less than 3 inches from each end and not more than 24 inches o.c. C. Seals in Metal Frames: Install elastomeric seals and membranes in frames to comply with manufacturer's written instructions. Install with minimum number of end joints. 1. Provide in continuous lengths for straight sections. 2. Seal transitions according to manufacturer's written instructions. Vulcanize or heat-weld field-spliced joints as recommended by manufacturer. 3. Installation: Mechanically lock seals into frames or adhere to frames with adhesive or pressure-sensitive tape as recommended by manufacturer. D. Compression Seals: Apply adhesive or lubricant adhesive as recommended by manufacturer before installing compression seals. E. Terminate exposed ends of joint assemblies with field- or factory-fabricated termination devices. F. Fire-Resistance-Rated Assemblies: Coordinate installation of architectural joint assembly materials and associated work so complete assemblies comply with assembly performance requirements. 1. Fire Barriers: Install fire barriers to provide continuous, uninterrupted fire resistance throughout length of joint, including transitions and field splices. G. Water Barrier: Provide water barrier at exterior joints and where called for on Drawings. Provide drainage fittings where indicated PROTECTION A. Do not remove protective covering until finish work in adjacent areas is complete. When protective covering is re moved, clean exposed metal surfaces to comply with manufacturer's written instructions. B. Protect the installation from damage by work of other Sections. Where necessary due to heavy construction traffic, remove and properly store cover plates or seals and install temporary protection over joints. Reinstall cover plates or seals prior to Substantial Completion of the Work To download detail, specs & photos visit For technical and design assistance call

287 Resources Expansion Joint Covers Links QUAKE.WR.USGS.GOV ( This United States Geological Service site has up-to-date earthquake information from California. It updates hourly and gives an excellent graphic view of seismic activity throughout the area. Also included are real time earthquake maps for the U.S. and the world. UL.COM ( An online resource for UL product information. You can search the UL certifications directory by company name, UL number or keyword. USGS Seismic Info Maps ( The USGS has assembled real-time maps of recent earthquake activity, real-time seismograms, regional earthquake activity reports, and recent significant earthquakes. GLOBAL EARTHQUAKE REPORT ( Text listing of recent worldwide seismic activity. RECENT EARTHQUAKES CALIFORNIA & NEVADA ( Map showing locations and intensity of recent and/or current seismic activity in the California and Nevada area. VISUALIBRARY.COM ( Visual Library is part of Bricsnet.com, which is related to Arcat (architects, engineers, contractors, facility owners, etc.) 9.1

288 US Earthquakes Causing Damage ( ) US Earthquakes Causing Damage Modified Mercalli Intensity VI - XII 50 N 120 W 110 W 100 W 90 W 80 W 70 W 50 N 40 N 40 N 30 N 30 N 120 W Intensity VI VII VIII IX X-XII 110 W 100 W 90 W 80 W Prepared by: USGS National Earthquake Information Center Data Source: Seismicity of the United States, Preliminary Determination of Epicenters, W 9.2 To download detail, specs & photos visit For technical and design assistance call

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Allway Expansion Joint Covers. Uniclass L555 CI/SfB (42)+(43)+(47) Xh June 2011

Allway Expansion Joint Covers. Uniclass L555 CI/SfB (42)+(43)+(47) Xh June 2011 Allway Expansion Joint Covers Uniclass L555 CI/SfB (42)+(43)+(47) Xh June 2011 2 ALLWAY EXPANSION JOINT COVERS C/S ALLWAY EXPANSION JOINT COVERS FLEXIBLE FINISHING SOLUTIONS FOR BUILDING MOVEMENT With

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Introducing NEW. Taking on joint pain, one joint cover at a time.

Introducing NEW. Taking on joint pain, one joint cover at a time. Introducing NEW Taking on joint pain, one joint cover at a time. C/S Restofit Joint Systems are ready to tackle your worst expansion joint areas. If these pictures look familiar, give us a call. (or send

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

A/E Project No January 27, 2014

A/E Project No January 27, 2014 SECTION 07 95 13 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION EXPANSION JOINT COVER ASSEMBLIES

SECTION EXPANSION JOINT COVER ASSEMBLIES SECTION 07 95 13 EXPANSION JOINT COVER ASSEMBLIES SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Do not use aluminum, brass, or bronze

More information

Expansion Joint Covers (079513)

Expansion Joint Covers (079513) Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION IMPACT RESISTANT WALL PROTECTION SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,

More information

SECTION WALL AND DOOR PROTECTION

SECTION WALL AND DOOR PROTECTION PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 26 00 WALL AND DOOR PROTECTION SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable to

More information

Unitised Curtain Wall Beaded

Unitised Curtain Wall Beaded Unitised Curtain Wall Beaded Glazed Frame Unitised Curtain Wall Reference Brand: Sapa Building System Elegance 72 GF GENERAL DESCRIPTION Unitised curtain wall system using glazing beads for glass retention.

More information

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Post

More information

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8" AIR SPACE 3 1 2" SCALE = FULL SIZE

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8 AIR SPACE 3 1 2 SCALE = FULL SIZE Since 906 Series The Series is a heavy triple glazed church window incorporated into a " thermally broken frame. The thermal break is achieved with the use of Thermal Strip technology. Two different aluminum

More information

Custom fabrication in two weeks or less, guaranteed.

Custom fabrication in two weeks or less, guaranteed. Custom fabrication in two weeks or less, guaranteed. Ramco is the midwest Kawneer distributor and fabricator. ramcometals.com got lead times? Ramco offers custom fabrication in two weeks or less, guaranteed!

More information

Trex Commercial Products page Metal Railing

Trex Commercial Products page Metal Railing SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Post Rail (Glass). D. Tensiline Railings (Cable). E. Track Rail (Glass).

More information

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window

More information

Accordion Doors / Zone 2. Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available

Accordion Doors / Zone 2. Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available SINCE 1957 Accordion Doors / Zone 2 Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available Suggested List Prices / All Continental States

More information

Accordion Doors / Zone 2. Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available

Accordion Doors / Zone 2. Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available SINCE 1957 Accordion Doors / Zone 2 Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available Suggested List Prices / All Continental States

More information

SUGGESTED SPECIFICATION SECTION ENTRANCE FLOOR MATS AND FRAMES

SUGGESTED SPECIFICATION SECTION ENTRANCE FLOOR MATS AND FRAMES Note: After downloading this spec, the Specifier must choose the correct Finish, Insert and Frame options and delete all other options to produce an accurate specification. DesignStep (BR) SUGGESTED SPECIFICATION

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL TEchnical bulletin PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION.......................................................................

More information

ENTRANCE MATS & GRIDS

ENTRANCE MATS & GRIDS 152 Rollins Avenue #102 Rockville, MD 20852 800-762-9010 240-780-3309 (f) http://www.americanfloormats.com ENTRANCE MATS & GRIDS PART I - GENERAL 1.01 Summary A. This section includes the following types

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Aluminum entrance doors and frames. 2. Glass infill panels. 3. Door hardware. B. Related Sections:

More information

Expansion Joint Covers

Expansion Joint Covers Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

C/S Expansion The Cathedral of Christ the Light /CON. BuyLine 1803

C/S Expansion The Cathedral of Christ the Light /CON. BuyLine 1803 C/S Expansion Joints @ The Cathedral of Christ the Light 07 95 00/CON BuyLine 1803 C/S EXPANSION JOINT COVERS No matter how much movement C/S @ de Young Museum A major consideration of the de Young project

More information

Accordion Doors / Zone 2. Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available

Accordion Doors / Zone 2. Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available SINCE 1957 Accordion Doors / Zone 2 Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available Suggested List Prices / All Continental States

More information

MPG Series 2250T Thermally Broken Aluminum Window

MPG Series 2250T Thermally Broken Aluminum Window SECTION 08520 ALUMINUM WINDOWS P a g e 1 MPG Series 2250T Thermally Broken Aluminum Window PART 1 GENERAL 1.01 Work Included A. Furnish and install aluminum architectural windows complete with hardware

More information

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION ORNAMENTAL ALUMINUM FENCING SECTION 032300 ORNAMENTAL ALUMINUM FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Custom fabrication in two weeks or less, guaranteed.

Custom fabrication in two weeks or less, guaranteed. Custom fabrication in two weeks or less, guaranteed. Ask us how Ramco can now fabricate hardware on all manufacturers blank doors in 2 weeks or less. ramcometals.com got lead times? Ramco offers custom

More information

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1 Page 1 This section includes standard commercial Stainless Steel Doors and Frames. This section relies on both the Canadian Steel Door Manufacturers Association (CSDMA.org) industry standard, as well as

More information

PanelGrip Dry Glaze Glass Railing System

PanelGrip Dry Glaze Glass Railing System Metric Version PanelGrip Dry Glaze Glass Railing System Patent Pending Nationwide supplier of trims, mouldings and components for the glass and mirror industry. Reduces Labor Costs up to 80% Reduces Freight

More information

Curtain Wall Stick System (Capped)

Curtain Wall Stick System (Capped) Curtain Wall Stick System (Capped) Stick Construction Capped Curtain Wall Reference Brand: Sapa Building System Elegance 52 ST GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL ALUMINUM RAILING SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Decorative Wire Rope Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

SECTION PASS WINDOWS. 1.1 SUMMARY A. Section Includes: 1. Factory finished sliding glass, counter mounted pass windows.

SECTION PASS WINDOWS. 1.1 SUMMARY A. Section Includes: 1. Factory finished sliding glass, counter mounted pass windows. SECTION 08 56 19 PASS WINDOWS SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Factory finished

More information

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware. 1 SECTION 08 4210 ALL GLASS ENTRANCES PART 1 - GENERAL 1.01 SUMMARY A. This section includes: 1. Vestibule doors matching entrance doors. 2. Sidelites. B. Related work in other sections: 1. Lock cylinders

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window E F C O C O R P O R A T I O N Visit us on the web at efcocorp.com IMPACT GRADE Series 3500 Thermal Series 3900 Fixed Thermal 3 1 4 Architectural Grade Horizontal Sliding Window Configurations XO OX XOX

More information

CAR PARKS DURABLE SOLUTIONS FOR CAR PARKS

CAR PARKS DURABLE SOLUTIONS FOR CAR PARKS CAR PARKS DURABLE SOLUTIONS FOR CAR PARKS PROVIDING WATERTIGHT TRANSITIONS WITH C/S ALLWAY EXPANSION JOINT COVERS Standard duty expansion joint covers aren t durable enough to withstand the constant heavy

More information

Specification Section Storefront Systems has been revised. Omit previously issued Storefront section.

Specification Section Storefront Systems has been revised. Omit previously issued Storefront section. December 28, 2018 ADDENDUM NO. 2 To: Re: Bidders Corey Pitts, NewQuest Properties This Addendum forms a part of the contract documents identified above. Acknowledge the receipt of this Addendum on the

More information

SPECIFICATIONS: Architectural Aluminum Railings

SPECIFICATIONS: Architectural Aluminum Railings PART ONE: GENERAL 1.1 SUMMARY SPECIFICATIONS: Architectural Aluminum Railings A. Work in this section includes custom and standard Interior and Exterior aluminum railings and guardrails. 1.2 PERFORMANCE

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Invisirail

More information

University Apartments on Brooklyn PROJECT MANUAL

University Apartments on Brooklyn PROJECT MANUAL Section 122100 Horizontal Louver Blinds University Apartments on Brooklyn PART 1 - GENERAL 1.1 SECTION INCLUDES A. Horizontal slat louver blinds. B. Operating hardware. 1.2 RELATED SECTIONS A. Section

More information

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM Expanding spaces to the extraordinary Overview Elevation View of a 4-panel Lift & Slide Door System - Stacked Configuration Panda s Lift & Slide Door Systems

More information

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS SECTION E INDEX CURTAINWALL FRAMING SYSTEMS E PAGE DESCRIPTION 0 CURTAINWALL FRAMING SPECIFICATION 0 SERIES /" () WIDE THERMALLY IMPROVED CURTAIN WALL FRAMING SYSTEM FOR SEALED UNIT GLAZING. 00 SERIES

More information

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A440-08

More information

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011. DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:

More information

AMBICO Limited Section and DETENTION STEEL DOOR AND FRAME ASSEMBLIES Page 1

AMBICO Limited Section and DETENTION STEEL DOOR AND FRAME ASSEMBLIES Page 1 Page 1 This section includes AMBICO Detention Steel Door and Frame assemblies that can be fire rated or non-rated. This section relies on both the Canadian Steel Door Manufacturers Association (CSDMA.org)

More information

A. Atlantic Railing Series with Mushroom Top and Square Pickets

A. Atlantic Railing Series with Mushroom Top and Square Pickets 100 Series-A1-A10 PART 1 General 1.1 SECTION INCLUDES A. Atlantic Railing Series with Mushroom Top and Square Pickets 1.2 RELATED SECTIONS A. Section 05510-Metal Stairs: Metal Handrails other than those

More information

SECTION ROOF ACCESSORIES

SECTION ROOF ACCESSORIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 72 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

1 3 4 Tie Rod Aluminum Swing Entrance Doors

1 3 4 Tie Rod Aluminum Swing Entrance Doors Windows Curtain Walls Entrances Storefronts Series T200 Narrow Stile Series T300 Medium Stile T500 Wide Stile Configurations Narrow Stile (2 1 8 ) Medium Stile (3 1 2 ) Wide Stile (5 ) EFCO tie rod entrances

More information

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL ALUMINUM RAILING SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Pipe Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in concrete.

More information

The S.15 ALL WOOD WITH ALUMINUM CORE LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

The S.15 ALL WOOD WITH ALUMINUM CORE LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary The S.15 ALL WOOD WITH ALUMINUM CORE LIFT & SLIDE DOOR SYSTEM Expanding spaces to the extraordinary Overview Elevation View of a 4-panel Lift & Slide Door System - Stacked Configuration Panda s Lift &

More information

In-Floor Access Enclosures

In-Floor Access Enclosures Manufacturers of In-Floor Access Enclosures Patent 5.4.911 Time Saving Installations, Convenience, Standardization For Gaining Access To Under Floor Mechanicals! Manufactured In-Floor access enclosures

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

STARRCO M O D U L A R O F F I C E S Y S T E M S S P A C E S O L U T I O N S F O R T O D A Y A N D T O M O R R O W

STARRCO M O D U L A R O F F I C E S Y S T E M S S P A C E S O L U T I O N S F O R T O D A Y A N D T O M O R R O W STARRCO M O D U L A R O F F I C E S Y S T E M S SPACE SOLUTIONS FOR TODAY W.W. Cannon, Inc. 2653 Brenner Dr. Dallas, TX 75220 Phone: 214-357-2846 Toll Free: 800-442-3061 Fax: 214-357-4576 www.wwcannon.com

More information

ALL-ALUMINUM DOOR & WINDOW FRAMING

ALL-ALUMINUM DOOR & WINDOW FRAMING ALL-ALUMINUM DOOR & WINDOW FRAMING WITH INTEGRATED ALUMINUM DOOR STOP SECTION 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS SPECIFICATION PART 1 GENERAL 1.1 SECTION INCLUDES: A. Prefinished aluminum

More information

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS [OR WOOD] PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8 SLIDING WINDOW PAGE 1 PAGE 1 SPECIFICATIONS GENERAL Sliding windows shall be Marlin series #3500-HC (thermally improved) as manufactured by Marlin windows, and shall conform to ANSI/AAMA 101-88 HS-HC40. Series #3500 shall have

More information

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American

More information

SECTION ENTRANCE FLOOR GRILLES SPECIFICATIONS

SECTION ENTRANCE FLOOR GRILLES SPECIFICATIONS SECTION 12 48 16 ENTRANCE FLOOR GRILLES SPECIFICATIONS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and

More information

HORIZONTAL SLIDER SERIES 700. Main Frame Depth: 2 3/4 Glazing Thickness (Maximum): 5/8 Thermal Break:

HORIZONTAL SLIDER SERIES 700. Main Frame Depth: 2 3/4 Glazing Thickness (Maximum): 5/8 Thermal Break: GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com HORIZONTAL SLIDER SERIES 700 Main

More information

Sliding Door Systems

Sliding Door Systems Sliding Door Systems Standard Sliding System Reference Brand: Sapa Building System Plaisance 24 GENERAL DESCRIPTION Sliding window and door system with a frame depth of 50 mm (two rail version), 97mm (three

More information

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY

More information

GLASS RAILINGS CARVART.COM. glassrailings 2018 CARVART

GLASS RAILINGS CARVART.COM. glassrailings 2018 CARVART GLASS RAILINGS glassrailings 28 CARVART INFO@ 212.675.0030 2 GLASS RAILINGS Top Mount C A R VA R T. C O M Side Mount TOP MOUNT > CONCEALED SIDE MOUNT > CONCEALED TOP MOUNT > EXPOSED S I D E M O U N T >

More information

A. Submit the following in addition to the standard requirements.

A. Submit the following in addition to the standard requirements. SECTION [13120] OMNIFLEX 300 MODULAR WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete modular wall system including,

More information

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window DIVISION 08 / SECTION 08505 METAL WINDOWS SILVER LINE BUILDING PRODUCTS SPECIFICATIONS: GENERAL Series 1700 Heavy Commercial Aluminum Double Hung 1. SECTION INCLUDES 2. RELATED SECTIONS 3. QUALITY ASSURANCE

More information

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish. SECTION 083113 - ACCESS DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PROFILES AND TRANSITIONS

PROFILES AND TRANSITIONS PROFILES AND TRANSITIONS Product Catalog Flooring Preparation & Installation Products Exclusively Manufactured By Combine beauty and function with high quality Profiles and Transitions. Enhance the appearance

More information

E-Wall System 5800, 5800-I

E-Wall System 5800, 5800-I Windows Curtain Walls Entrances Storefronts E-Wall System 5800, 5800-I The beauty of EFCO s E-Wall Silicone Gasket curtain wall system is the simplicity in which it is installed. There are no internal

More information

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 10560 MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

STEEL STRUCTURAL SYSTEMS

STEEL STRUCTURAL SYSTEMS STEEL STRUCTURAL SYSTEMS Steel elements are of two basic types: Structural steel shapes are formed into their final shapes by hot-rolling. This method produces such common elements as wide flange sections,

More information

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 International Fireproof Technology Inc. 17528 Von Karman Avenue Irvine, CA 92614 This report is for the exclusive

More information

Operable / Fixed Skylight Milgard Aluminum Window

Operable / Fixed Skylight Milgard Aluminum Window Skylight Operable / Fixed Skylight Milgard Aluminum Window The Series Skylight has been specifically designed to provide maximum thermal efficiency by incorporating a special polyurethane barrier between

More information

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade. MANUFACTURER S SPECIFICATIONS Section 03330 LIME CONCRETE ST. ASTIER NATURAL HYDRAULIC LIME CONCRETE PART 1 GENERAL 1.01 General A. This section describes the requirements for floors and slabs on grade.

More information

SECTION DIRECTORIES

SECTION DIRECTORIES PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 13 00 DIRECTORIES SPEC WRITER NOTES: 1. Delete // // if not applicable to project. Also delete any other item or paragraph not applicable in the section and

More information

Heavy Commercial / Architectural Projected Windows Series L900T AW150

Heavy Commercial / Architectural Projected Windows Series L900T AW150 Heavy Commercial / Architectural Projected Windows Series L900T AW150 Section 08520...Aluminum Windows PART 1: WORK INCLUDED GUIDE SPECIFICATION A. The conditions of the contract and applicable sections

More information

A. Glass Railing Series with Mushroom Top Cap with Glass Panel Infill.

A. Glass Railing Series with Mushroom Top Cap with Glass Panel Infill. 100 Series Bayview ( Two-Line) Glass Rail-A1 Top Cap PART 1 General 1.1 SECTION INCLUDES A. Glass Railing Series with Mushroom Top Cap with Glass Panel Infill. 1.2 RELATED SECTIONS A. Section 03300 Cast-

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

Series 510-I Thermal Heavy Commercial Projected Window

Series 510-I Thermal Heavy Commercial Projected Window Windows Curtain Walls Entrances Storefronts Series 510-I Thermal 2-7 16 Heavy Commercial Projected Window Configurations Project-In Project-Out Casement Fixed Series 510-I retains an AAMA Architectural

More information

PrivaSEE All Glass Single Track Sliding System for Acoustical Separation

PrivaSEE All Glass Single Track Sliding System for Acoustical Separation INTRODUCTION PRIVASEE PrivaSEE All Glass Single Track Sliding System for Acoustical Separation Control Sound Transparently NanaWall PrivaSEE is the only all glass single track sliding system specifically

More information

MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series

MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series SECTION 08520 ALUMINUM WINDOWS P a g e 1 MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series PART 1 GENERAL 1.01 Work Included A. Furnish and install aluminum architectural windows

More information

SECTION SERIES ALL GLASS ENTRANCES

SECTION SERIES ALL GLASS ENTRANCES 1 SECTION 08 4210 1200 SERIES ALL GLASS ENTRANCES PART 1 - GENERAL 1.01 SUMMARY A. This section includes: 1. Vestibule doors matching entrance doors. 2. Sidelites. B. Related work in other sections: 1.

More information

MOVEABLE GLASS WALL TECHNICAL DATA

MOVEABLE GLASS WALL TECHNICAL DATA Modernfold Compactline Technical Data Ideal for applications requiring space division, visibility, and security. Used in banks, office lobbies, conference areas, interior storefronts, and arena skyboxes.

More information

Wabo Allure, AFJ Interior Floor Seismic Expansion Control System

Wabo Allure, AFJ Interior Floor Seismic Expansion Control System Installation Procedure Last Updated: February 28 th, 2018 Wabo Allure, AFJ 100-400 Interior Floor Seismic Expansion Control System The following installation procedure is very important and must be fully

More information

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700 SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs. PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs. 1.2 PERFORMANCE REQUIREMENTS A. Structural

More information

SECTION HVAC GRAVITY VENTILATORS

SECTION HVAC GRAVITY VENTILATORS SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION AWNINGS

SECTION AWNINGS SECTION 10 73 13 AWNINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Fixed metal awnings. 1.2 DEFINITIONS A. Awning: An architectural projection that provides weather protection,

More information

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors 2000/2100/2200 Series Heavy Commercial Sliding Patio Doors MANKO WINDOW SYSTEMS, INC. 800 HAYES DRIVE MANHATTAN, KANSAS 66502 PHONE: (800) 642-1488 (785) 776-9643 FAX: (800) 576-2656 (785) 776-9644 MANKO

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 08 51 69.11 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

Model 2020 Individual Panels / Multi-Directional

Model 2020 Individual Panels / Multi-Directional Model 2020 Individual Panels / Multi-Directional Introduction: The following three (3) part specification offers the Standard and Optional features for the Model 2020 Multi-Directional Operable Wall System.

More information

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS DIVISION 10 SPECIALTIES SECTION 10 51 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

LOG COLLEGE MIDDLE SCHOOL

LOG COLLEGE MIDDLE SCHOOL PART 1-GENERAL 1.1 SUMMARY A. This section includes the following: 1. Curb-mounted plastic glazed skylights. B. Refer to roofing system sections for roofing accessories to be built into the roofing system

More information