Variety of uses: Universal Pool Skimmer Cover, Water Main, Valves, Waterfalls & Fountains, Sewer Cleanouts MADE IN USA. Also Available in Gray & Tan

Size: px
Start display at page:

Download "Variety of uses: Universal Pool Skimmer Cover, Water Main, Valves, Waterfalls & Fountains, Sewer Cleanouts MADE IN USA. Also Available in Gray & Tan"

Transcription

1 MADE IN USA Variety of uses: Universal Pool Skimmer Cover, Water Main, Valves, Waterfalls & Fountains, Sewer Cleanouts Also Available in Gray & Tan Pour-A-Lid is a product of Stetson Development, Inc. For further information call (800) or fax (951) Come visit our website at

2 Pour-A-Lid 201 PAL Tan 201 PAL Grey 201 PAL Clear Now with universal fit and screw down capability 10 Pour-A-Lid Pool Skimmer Cover for New Construction Fits: Hayward 1070, Hayward 1080, Waterway, Sta-Rite, Swimquip, U3, Jacuzzi, American, Pentair/Pacfab 204 PAL Tan 204 PAL Grey Screw down capability 9 Pour-A-Lid Replacement Lid for existing Pool Skimmer Fits: Hayward 1070, Waterways, Sta-Rite, U3, MP Auto Fill 202 PAL Tan 202 PAL Grey 202 PAL Clear 6 Pour-A-Lid Cover Fits: Play Equipment, Sewer Cleanouts, Valves, Water Main Also Available Automatic Water Level System SDI-WF420 Includes a Pour-A-Lid For further information: Call (800) Fax (951) Pour-A-Lid is a product of Stetson Development, Inc. Patent #6,393,771 B1 visit our website at :

3 Stetson Development Inc. ABS Auto Fill Standard Available in 3/8 #3-8ATF 1/2 #1-2ATF Standard pipe thread inlet and free flow outlet Adjustable arm can be used in the vertical or horizontal position Estimated flow rate of 1.5 at 40 PSI.093 orifice Approximate overall length of 7.5 ABS construction Excellent for Ponds, Fountains and MP-Auto Fills For further information contact Mike: Phone (800) Fax (951) Bramble Ct., Lake Elsinore, CA visit our website at

4 ABS Auto Fill Standard 3-8ATF 3-8ATFLA 1-2ATF 1-2ATFLA 3-8ATF 3-8ATFLA 1-2ATF 1-2ATFLA 1-4ATFC 3/8 Auto-Fill 3/8 Auto-Fill with 5 extension 1/2 Auto-Fill 1/2 Auto-Fill with 5 extension 1/4 Auto-Fill with Compression Fitting Swamp Coolers Pool Water Levelers Variety of Uses Fountains Ponds Cooling Towers Live Stock Water Feeders For further information: ABS Auto-Fill is a product of Stetson Development, Inc. Patent Pending Call (800) Fax (951) visit our website at :

5 Pour-A-Lid and Pour-A-Lid Automatic Water Level System are products of Stetson Development, Inc. For further information call (800) or fax (951) Come visit our website at Lid also Available in Gray & Tan

6 Automatic Water Level System Coping Decking Bond Beam Top of bond beam reference level point 1/2 PVC Pipe Over Flow (optional) 1/2 ABS Float Valve Adjustable Float Arm 1 1/2 Equalizer Drawing not to Scale SDI WF 420 PAL Tan SDI WF 420 PAL Grey SDI WF 420 PAL Clear 10 Pour-A-Lid Pool and Pond Automatic Water Level System For further information: Pour-A-Lid is a product of Stetson Development, Inc. Patent #6,393,771 B1 Call (800) Fax (951) visit our website at :

7 Made in USA Pour-A-Drain is a product of Stetson Development, Inc. For further information call (800) or fax (951) Come visit our website at Patent Pending

8 Pour-A-Drain Easy to Install 1. Cut pipe and set top of coupling to finished drain elevation. Make sure coupling is facing up. 2. For best results remove drain insert from coupling use tape or paper to keep drain coupling free of construction debri. 3. Pour concrete or cut stone to finished surface elevation. Fill with stone or concrete. 4. Cut stone or pour concrete into drain cap. For best results tap bottom of drain cap to settle concrete into place. 5. When concrete is cured clean coupling and drain cap. Install drain cap into coupling. DC 401 Tan DC 401 Gray DC 401 Clear 4 SDR35 3 drain pipe / Specifications 4 Round Poly Resin Grate with Universal Fit 3 to 4 Collar Fits: 3 or 4 SDR-35 Drain Pipe 3 Open surface area SQ.IN G.P.M Recommended Load Class A Load at 1-60 PSI For Pedestrians, Bicycles and Wheel Chair Traffic Loads are based on encasing product in Concrete For further information: Call (800) Fax (951) Pour-A-Drain is a product of Stetson Development, Inc. Patent Pending visit our website at :

BRILLIANT WONDERS LED WATERFALL INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED WATERFALLS

BRILLIANT WONDERS LED WATERFALL INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED WATERFALLS R BRILLIANT WONDERS LED WATERFALL INSTALLATION INSTRUCTIONS CMP 25677 SERIES Brilliant Wonders LED WATERFALLS TABLE OF CONTENTS 1 Product Overview....2 1.1. Packing List...2 2 Safety.3 3 Installation Guide.....4

More information

INSTALLATION INSTRUCTIONS CMP SERIES

INSTALLATION INSTRUCTIONS CMP SERIES INSTALLATION INSTRUCTIONS CMP 25677 SERIES 1. PRODUCT OVERVIEW Thank you for choosing our 25677 Series Brilliant Wonders LED Waterfall. This lighted waterfall will add a unique ambiance to your pool or

More information

Inground Pool Liners

Inground Pool Liners Inground Pool Liners 20 Mil or 30 Mil Pool Liner ALL SIZES AND STYLES AND PATTERNS AVAILABLE PLEASE CALL FOR MEASUREMENT SHEET AND PRICING Pool Safety Stingl Switch When a blockage occurs it shuts down

More information

Inground Pool Liners

Inground Pool Liners Inground Pool Liners 20 Mil or 30 Mil Pool Liner ALL SIZES AND STYLES AND PATTERNS AVAILABLE PLEASE CALL FOR MEASUREMENT SHEET AND PRICING Pool Safety Stingl Switch When a blockage occurs it shuts down

More information

Inground Pool Liners

Inground Pool Liners Inground Pool Liners 20 Mil or 30 Mil Pool Liner ALL SIZES AND STYLES AND PATTERNS AVAILABLE PLEASE CALL FOR MEASUREMENT SHEET AND PRICING Pool Safety Stingl Switch When a blockage occurs it shuts down

More information

Drainage and Erosion Control

Drainage and Erosion Control Drainage and Erosion Control Erosion Control To order Straw Waddle 020897 Straw Waddle 9" x 25 Roll 14 Rolls/ None 140209 Wood Stakes 1" x 2" x 18" 50 Pcs./Bndl. None Straw fiber rolls that control erosion

More information

Toll Free Order Line: or Fax: Advantage Leisure Products Ltd. All rights reserved.

Toll Free Order Line: or Fax: Advantage Leisure Products Ltd. All rights reserved. Pool Safety Stingl Switch When a blockage occurs it shuts down the pump to prevent injury or death. Works on all single speed pool or spa pumps up to 3 hp. Stock Number: Size: List Price: SR500 Stingl

More information

Fiberstars Lighted Laminar Flow Fountains

Fiberstars Lighted Laminar Flow Fountains Fiberstars Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Lighted Laminar Flow Fountain. The maximum lighted

More information

www.arizonawholesalepoolcontractors.com The Swimming Pool Construction Checklist is designed to give you some guidelines and hints of items to look for while you re building your own pool. It s outline

More information

Toll Free Order Line: or Fax: Advantage Leisure Products Ltd. All rights reserved.

Toll Free Order Line: or Fax: Advantage Leisure Products Ltd. All rights reserved. Pool Safety Stingl Switch When a blockage occurs it shuts down the pump to prevent injury or death. Works on all single speed pool or spa pumps up to 3 hp. Stock Number: Size: List Price: SR500 Stingl

More information

YOUR SPLASH PAD RESOURCE

YOUR SPLASH PAD RESOURCE 1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature

More information

Concrete Answers for Better Living. Plastics

Concrete Answers for Better Living. Plastics Concrete Answers for Better Living Plastics Leaders in Innovation for Over 40 Years The Mortex Difference Concrete Answers for Better Living For over 40 years, Mortex has been the contractor s choice for

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

FLOOR AND AREA DRAINS

FLOOR AND AREA DRAINS Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA

More information

SECTION PLUMBING SPECIALTIES

SECTION PLUMBING SPECIALTIES PART 1 GENERAL 1.1 SCOPE SECTION 22 20 00 PLUMBING SPECIALTIES A. Work consists of all plumbing work indicated on drawings and specified herein. B. Also included are all fees and permits for installation

More information

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING STANDARD CONSTRUCTION DETAILS REVISED MARCH 2018 GENERAL NOTES EMBEDMENT DETAILS EMBEDMENT DETAILS TWO-WAY CLEANOUT - EXISTING LATERAL TWO-WAY CLEANOUT - NEW CONSTRUCTION TYPICAL SEWER HOUSE SERVICE CONNECTION

More information

CHAPTER 12 INSTALLATION OF UTILITIES AND OTHER SYSTEMS TABLE OF CONTENTS

CHAPTER 12 INSTALLATION OF UTILITIES AND OTHER SYSTEMS TABLE OF CONTENTS CHAPTER 12 INSTALLATION OF UTILITIES AND OTHER SYSTEMS TABLE OF CONTENTS Section Title Page 12.1 General... 12-1 12.2 Design Standards... 12-1 12.2.1 General Requirements...12-1 12.2.2 Minimum Depth...12-1

More information

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms. PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

PHASE 1 Foundation & Drainage New Construction Phased Inspection Report John & Mary Doe 5237 Clinton Street, Denver, CO 80238

PHASE 1 Foundation & Drainage New Construction Phased Inspection Report John & Mary Doe 5237 Clinton Street, Denver, CO 80238 PHASE 1 Foundation & Drainage New Construction Phased Inspection Report John & Mary Doe 5237 Clinton Street, Denver, CO 80238 PHASE 1 Foundation & Drainage New Construction Phased Inspection Report Buyers

More information

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER WATER MAIN 1. All open cut water main shall be polyvinyl chloride plastic (PVC) pressure pipe per AWWA specification

More information

D. Encase exterior cleanouts in concrete with access cover installed flush with grade.

D. Encase exterior cleanouts in concrete with access cover installed flush with grade. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

SV24. Submittal Special Precautions Specifications Installation. 12½ (31.8 cm) 12½ (31.8 cm) 12 (30.5 cm) 12 (30.5 cm) 12 (30. Wastewater Sampling Port Technical Data Submittal Special Precautions Specifications Installation 16½" (31.8 (41.9 cm) 8" (20.3 cm) -L -O SUBMITTAL STANDARD: 4" plain end inlet/outlet Highway traffic load

More information

Installation Instructions

Installation Instructions Installation Instructions (for part no:s HD100SN, HD100N, HD100LAK, HD1001SCS, HD1001CS, HD1001SLS, HD1001LS, HD101LS) s - Pool Installation (Part Nos: HD100SN Collar Weir or HD100N Flap Weir & HD100LAK)

More information

5.0 ENDURA GREASE MANAGEMENT. Endura Grease Interceptors with Spigot format Flow Control Devices.

5.0 ENDURA GREASE MANAGEMENT. Endura Grease Interceptors with Spigot format Flow Control Devices. GREASE MANAGEMENT 5.0 ENDURA GREASE MANAGEMENT New! With Spigot Format Flow Control Devices Diffuser Baffle supplied only with 35/50 GPM models Canplas is pleased to announce the extension of our Endura

More information

PLASTIC FITTINGS Avenue Edmonton, AB Canada T6E 5Z7. Toll Free: Phone: (780) Fax: (780)

PLASTIC FITTINGS Avenue Edmonton, AB Canada T6E 5Z7. Toll Free: Phone: (780) Fax: (780) 9333 45 Avenue Edmonton, AB Toll Free: 1-800-272-9693 Phone: (780) 436-1930 Fax: (780) 435-4849 info@can-con.com TABLE OF CONTENTS PLASTIC FITTINGS POLYETHYLENE PIPE...- 1 - SERVICE RISERS... - 3 - TRANSITION

More information

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms. SECTION 22 13 00 FACILITY SANITARY SEWERAGE PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

SECTION SANITARY UTILITY SEWERAGE PIPING

SECTION SANITARY UTILITY SEWERAGE PIPING SECTION 33 31 00 SANITARY UTILITY SEWERAGE PIPING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Sanitary sewer pipe and fittings. 2. Underground pipe markers. 3. Connection to existing manholes. 4.

More information

STORM DRAINAGE CHAPTER 11

STORM DRAINAGE CHAPTER 11 CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,

More information

STORM DRAINAGE CHAPTER 11

STORM DRAINAGE CHAPTER 11 CHAPTER STORM DRAINAGE SECTION 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage, except in one- and two-family dwellings.

More information

Series. 6 Wide POLYCAST 600 SP Polymer Concrete Trench Drain Kit

Series. 6 Wide POLYCAST 600 SP Polymer Concrete Trench Drain Kit TPC600SP Complete Kit TPC600SP Cut Sheet Polycast 600 6 Wide POLYCAST 600 SP Polymer Concrete Trench Drain Kit New Polymer Concrete Trench Drain Complete Kit 6 Inch Wide - C Class Spiral Decorative Grate

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

TYPICAL INSTALLATION INSTRUCTIONS

TYPICAL INSTALLATION INSTRUCTIONS TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect

More information

200 Series In-Slab Pool Fittings

200 Series In-Slab Pool Fittings 230 Series nti-vortex Plate 2-2 231 Series Sump 2-3 234 Series Sump 2-4 236 Series Sump 2-5 253 Series Overflow 2-6 255 Series Overflow/Drain 2-7 261 Series Vacuum Fitting 2-8 263 Series Eyeball Fitting

More information

Project Location: Various, Anywhere, PA Bid Date: 7/16/ Rock Construction Entrance

Project Location: Various, Anywhere, PA Bid Date: 7/16/ Rock Construction Entrance To: Project Name: Bidding Company Site Work Project Contact: Address: Various Phone: Fax: Bid Number: Project Location: Various, Anywhere, PA Bid Date: 7/16/2014 Clarifications: This takeoff does not include

More information

Page 1- MAGNEIS PANEL POOLS 2- BETON BLOCK POOLS

Page 1- MAGNEIS PANEL POOLS 2- BETON BLOCK POOLS 390 Page - MAGNEIS PANEL POOLS - BETON BLOCK POOLS 39 395 39 Prefabricated Swimming Pools - MAGNELIS PANEL MAGNELIS PANEL is a latest addition of Aqua SpA in the prefabricated structures field. This is

More information

POLYLOK / ZABEL PRODUCT BROCHURE v.3

POLYLOK / ZABEL PRODUCT BROCHURE v.3 POLYLOK / ZABEL PRODUCT BROCHURE v.3 Heavy Duty Trench Drain (Black, Grey, Green, Tan & Ductile ) 3, 4, 6, 8, 10 & 12 Black & Green Pipe s Flow Gate 12 Polylok & Pipe Adapter Ring x3 / Pan x2 & 24 x2 X-Chairs

More information

Product Manual PV1700 / PV1800 / PV2300 / PV18EXT / PV23EXT / SP1600 / SP1900 / SP2600 / SP

Product Manual PV1700 / PV1800 / PV2300 / PV18EXT / PV23EXT / SP1600 / SP1900 / SP2600 / SP PF Product Manual PV1700 / PV1800 / PV2300 / PV18EXT / PV23EXT / SP1600 / SP1900 / SP2600 / SP3800 1.330.274.8317 www.atlanticwatergardens.com Table of Contents Eco-Blox Reservoirs... 2 Gravel-Filled Reservoirs...3

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Color Light Stream Lighted Rain Waterfall Installation Manual Part number Description CLSRW24-8 Color Light Stream Lighted Rain Waterfall 24 CLSRW36-8 Color Light Stream Lighted Rain Waterfall 36 CLSRW48-8

More information

University of Central Florida Main Campus. Domestic Water. Service and Meter Installations Requirements. Issued January 26 th, 2017.

University of Central Florida Main Campus. Domestic Water. Service and Meter Installations Requirements. Issued January 26 th, 2017. University of Central Florida Main Campus Domestic Water Service and Meter Installations Requirements Issued January 26 th, 2017 1 P a g e Table of Contents 1. GENERAL INFORMATION... 3 2. DEFINITIONS...

More information

FIELD GUIDE FOR MILLENNIUM MOUNDS CLERMONT CO. GENERAL HEALTH DISTRICT 2010

FIELD GUIDE FOR MILLENNIUM MOUNDS CLERMONT CO. GENERAL HEALTH DISTRICT 2010 FIELD GUIDE FOR MILLENNIUM MOUNDS CLERMONT CO. GENERAL HEALTH DISTRICT 2010 DIMENSIONS BETWEEN DRAINS SINGLE LENGTH MOUND 2 BEDROOM 98 X 20 3 BEDROOM 139 X 20 4 BEDROOM 184 X 20 HALF STRUCTURE MOUND 2

More information

0.75 " transparent hose w/ valve for head measurements fixed to screws 20 MIL PVC liner. 6" gate valve

0.75  transparent hose w/ valve for head measurements fixed to screws 20 MIL PVC liner. 6 gate valve 0.75 " transparent hose w/ valve for head measurements fixed to screws 250x1000 RC beam 6" gate valve Foundation preparation in accordance with technical specifications and as approved by engineer 25 cm

More information

RADIAL FLOW SETTLER 60 CONE (RFS-60)

RADIAL FLOW SETTLER 60 CONE (RFS-60) RADIAL FLOW SETTLER 60 CONE (RFS-60) INSTALLATION AND OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 2 CUSTOMER SERVICE / TECHNICAL SUPPORT If you

More information

Pre-Sloped Drain System

Pre-Sloped Drain System SportsEdge PolyDrain Pre-Sloped Drain System www.sportsedge.com Quality. Safety. Versatility. Aesthetics. 2 PolyDrain FORMULA www.sportsedge.com ABT, Inc. manufactures PolyDrain trench drains; the standard

More information

How To Construct a Ferro Cement Tank

How To Construct a Ferro Cement Tank How To Construct a Ferro Cement Tank Be Advised The following power point presentation assumes that individuals using it to construct ferro-cement tanks have a basic knowledge of geometry and calculating

More information

1. Required Minimum Flow:

1. Required Minimum Flow: SECTION 6 6. 6.01 General The City of Castle Rock Water System Minimum Standards and Specifications are minimum base level performance, design, and construction standards used to maintain uniformity of

More information

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork. PAGE 334000-1 SECTION 334000 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

TECHNICAL SPECIAL PROVISION FOR FINANCIAL PROJECT ID:

TECHNICAL SPECIAL PROVISION FOR FINANCIAL PROJECT ID: TECHNICAL SPECIAL PROVISION FOR 1001 WATER DISTRIBUTION SYSTEM FINANCIAL PROJECT ID: 200105-7-52-01 The official record of this Technical Special Provision is the electronic file signed and sealed under

More information

Never ones to rest on our laurels, at NDS we ve taken our popular, easy-to-install Pro Series Channel Drain and made it even better.

Never ones to rest on our laurels, at NDS we ve taken our popular, easy-to-install Pro Series Channel Drain and made it even better. MODuLAr CHANNEL DrAiNS Patented PrO SEriES CHANNEL DrAiNS HAvE you SEEN THE NEW AND improved PrO SEriES CHANNEL DrAiN? Never ones to rest on our laurels, at NDS we ve taken our popular, easy-to-install

More information

Grease Management. EnduraGreaseManagement.com. Rethinking Grease Interception

Grease Management. EnduraGreaseManagement.com. Rethinking Grease Interception Grease Management EnduraGreaseManagement.com Rethinking Grease Interception Endura has the right stuff The Right Reason Guided by a philosophy of minimizing downstream toxic waste, Endura engineers have

More information

SUPPLEMENTAL SPECIFICATIONS AND DRAWINGS TO THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION TABLE OF CONTENTS

SUPPLEMENTAL SPECIFICATIONS AND DRAWINGS TO THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION TABLE OF CONTENTS PREFACE AND CITY ENGINEER S LETTER INDEX OF STANDARD DRAWINGS DIVISION 100 GENERAL CONDITIONS ARTICLE 1 DEFINITIONS AND TERMINOLOGY 1.01 Defined Terms ARTICLE 2 PRELIMINARY MATTERS 2.01 Delivery of Bonds

More information

SURFACE DRAINAGE SYSTEMS

SURFACE DRAINAGE SYSTEMS SURFACE DRAINAGE SYSTEMS Plumbing & Drainage Solutions pg 1 pg 3 130mm channel system shallow channel system CONTENTS LOADING CLASS LIGHT TRUCK CAR Light weight commercial vehicle driving at no more than

More information

QUOTE Quote Process City Of Taylor

QUOTE Quote Process City Of Taylor PROJECT SPECIFICATIONS QUOTE Quote Process City Of Taylor Budget & Finance Dept. Purchasing Manager: RMM 23555 Goddard Road Taylor, MI 48180 734-374-1459 The City of Taylor Central Purchasing Division

More information

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY Section Includes: 1. Pipe and fittings. 2. Drain Basin. 3. De-chlorination tablet feeder. 4. Non-pressure transition couplings.

More information

SPECIAL SPECIFICATION 3504 Septic Tank System

SPECIAL SPECIFICATION 3504 Septic Tank System 1993 Specifications CSJ s 3136-01-126, etc. & 0683-01-070, etc. SPECIAL SPECIFICATION 3504 Septic Tank System 1. Description. This Item shall govern for all materials, equipment and labor necessary for

More information

Installation Manual. Read the complete installation manual and Owners Manual before beginning the installation.

Installation Manual. Read the complete installation manual and Owners Manual before beginning the installation. Installation Manual Read the complete installation manual and Owners Manual before beginning the installation. 1. Sizing the System Size the system using the Simplified Sizing Guide For Solar Pool Heaters.

More information

SYSTEMS LTD. Leader in Linear Drain Solutions. A Publication of. Page 1. Randy Franzke. Cellar Master Supplies. Phone:

SYSTEMS LTD. Leader in Linear Drain Solutions. A Publication of. Page 1. Randy Franzke. Cellar Master Supplies. Phone: Page 1 SYSTEMS LTD. Leader in Linear Drain Solutions www.slotdrainsystems.com A Publication of Randy Franzke Cellar Master Supplies Phone: 707-307-8250 http://cellarmastersupplies.com Table of Contents

More information

PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT]

PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT] PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT] A. - General. B. - Streets. C. - Stormwater drainage system. D. - Water

More information

olor Match POOL FITTINGS, INC. Blending Beauty & Function

olor Match POOL FITTINGS, INC. Blending Beauty & Function olor Match POOL FITTINGS, INC. Blending Beauty & Function PEBBLE TOP DRAIN Patent # s 6,209,586 / 6,340,035 / 6,557,588 Additional patents pending 20-INCH VGB UNBLOCKABLE CONVERTIBLE DRAIN TWO DRAINS IN

More information

A. This Section includes the following sanitary drainage piping specialties:

A. This Section includes the following sanitary drainage piping specialties: Page 221319-1 SECTION 221319 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Skimmers. The Industry Standard for Performance and Reliability. For All Types of Inground and Aboveground Swimming Pools

Skimmers. The Industry Standard for Performance and Reliability. For All Types of Inground and Aboveground Swimming Pools Skimmers The Industry Standard for Performance and Reliability For All Types of Inground and Aboveground Swimming Pools Admiral S15 Admiral Skimmers Built tough for reliable service. Admiral skimmers offer

More information

CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413

CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413 Page: 1 of 5 CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413 COMMERCIAL/RESIDENTIAL UTILITY PLAN COMPLETENESS CHECK LIST Updated

More information

Welcome: What is U-Drain? Drain Materials. Flow

Welcome: What is U-Drain? Drain Materials. Flow Welcome: Thank you for looking into the U-Drain floor drain system. This paper will explore the functional features of the U-Drain and why it is superior to other grated systems in the marketplace. We

More information

Proper Construction of detention and sediment basins and their conversions

Proper Construction of detention and sediment basins and their conversions Proper Construction of detention and sediment basins and their conversions By Chris Droste, CESCO Senior Erosion Control Specialist Westmoreland Conservation District Discussed topics Pond embankment construction

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 33 3400 STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES SECTION 23 21 13 HYDRONIC PIPING A. ANSI/ASME SEC 9: Welding and Brazing Qualifications B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300 C. ANSI/ASME

More information

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INSTALL MANHOLE LIDS FLUSH WITH EXISTING GROUND SURFACE.

More information

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm) Wastewater Flow Distributor Technical Data Submittal Special Precautions Specifications Installation 24½" (62.2 cm) 12½" (31.8 cm) 24½" (62.2 cm) (30.5 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet

More information

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS IRRIGATION EQUIPMENT LTD. FERTILIZER T A N K S SERIES 6000 APPLICATIONS Designed specifically for fertigation in agriculture Simple, efficient and trouble free operation. Standard models apply fertilizer

More information

POLYCAST Trench Drain Systems

POLYCAST Trench Drain Systems POLYCAST 3621 Industrial Park Drive Lenoir City, TN 37771 Phone: 800-346-3061 Fax: 865-986-0585 Email: hpsliterature@hubbell.com www.polycastdrain.com POLYCAST Trench Drain Systems FP800 Series Specification

More information

SECTION FACILITY SANITARY SEWERS

SECTION FACILITY SANITARY SEWERS SECTION 22 13 13 FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES SECTION 23 21 13 HYDRONIC PIPING A. ASME BPVC Section IX - Welding and Brazing Qualifications B. ASME B16.3 - Malleable Iron Threaded Fittings Classes 150 and 300 C. ASME

More information

DEPARTMENT OF PUBLIC UTILITIES

DEPARTMENT OF PUBLIC UTILITIES DEPARTMENT OF PUBLIC UTILITIES Orangeburg, South Carolina PLUMBING RULES AND REGULATIONS TABLE OF CONTENTS Section Page 1.0 General... 1 1.1 Definitions... 1 2.0 Water Distribution System... 3 2.1 Water

More information

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 ) SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 ) WARNING - When unpacking SpaVault, DO NOT discard styrofoam pieces, these are not packaging materials. Step 1 Excavation Important:

More information

Section 403. DRAINAGE STRUCTURES

Section 403. DRAINAGE STRUCTURES 403.01 Section 403. DRAINAGE STRUCTURES 403.01. Description. This work consists of adjusting, constructing, or temporarily lowering drainage structures and cleaning existing drainage structures and leads

More information

CHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION.

CHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION. Standard Drawings Index NOTE: The specifications for materials and workmanship shall conform to the latest edition or the "Standard Specifications for Public Works Construction" published by the North

More information

City of Fort Walton Beach Engineering Standards Manual November City of Fort Walton Beach Engineering Standards Manual

City of Fort Walton Beach Engineering Standards Manual November City of Fort Walton Beach Engineering Standards Manual City of Fort Walton Beach Manual TABLE OF CONTE SECTION 1.00 INTRODUCTION... 3 SECTION 2.00 POLICY... 3 SECTION 3.00 - EROSION AND SEDIMENTATION CONTROL... 3 EROSION AND SEDIMENTATION CONTROL STANDARD

More information

Hi-Cap Slotted Drainage System Surface Drainage

Hi-Cap Slotted Drainage System Surface Drainage Hi-Cap Slotted Drainage System Surface Drainage Hi-Cap Slotted Drainage System The Zurn Z888 Hi-Cap is a modular slotted drain system constructed from linear low-density polyethylene and is equivalent

More information

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities. Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities. Whether it is new construction, renovation or operation,

More information

YAKIMA COUNTY, WASHINGTON. Special Provisions For Water Main Construction

YAKIMA COUNTY, WASHINGTON. Special Provisions For Water Main Construction YAKIMA COUNTY, WASHINGTON Special Provisions For Water Main Construction The 2014 Standard Specifications for Road, Bridge, and Municipal Construction as prepared by the Washington State Department of

More information

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1 DIVISION 3: SEWER 3.1 DESIGN CRITERIA A. APPLICABILITY 1. These Design Standards shall govern all construction and upgrading of public sanitary sewer facilities in the City of Dundee and applicable work

More information

APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES

APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES B-1 General Notes: SACWSD Standard Construction Drawing Notes 1. No work shall begin on any water or wastewater construction project until the construction

More information

ASHWELL FIRE PIT SIENNA QUARRY GRAY TAN AUTUMN BLEND. Plan Date: June 2016

ASHWELL FIRE PIT SIENNA QUARRY GRAY TAN AUTUMN BLEND.   Plan Date: June 2016 ASHWELL FIRE PIT QUARRY GRAY 198-620 SIENNA 198-621 TAN 198-622 AUTUMN BLEND 198-623 Plan Date: June 2016 Approximate Weight: 1,300 lbs Approximate Size: 4 2 Ext. 3 0 Intr. 1 2 H www.midwestmanufacturing.com

More information

Welcome: What is U Drain? Drain Materials. Cost Comparisons

Welcome: What is U Drain? Drain Materials. Cost Comparisons Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We

More information

4.28 Underground Detention

4.28 Underground Detention 4.28 Underground Detention Detention Structural Stormwater Control Description: Detention storage located in underground tanks or vaults designed to provide water quantity control through detention and/or

More information

FLOOR DRAINS GENERAL INFORMATION

FLOOR DRAINS GENERAL INFORMATION FLOOR DRAINS 11 FLOOR DRAINS GENERAL INFORMATION All floor drains and rodding eyes are made from stainless steel V2A (AISI 304) or V4A (AISI 316). The floor drain type depends on the load, amount of drained

More information

1 ½

1 ½ HOW TO SELECT A FLOOR DRAIN Floor and area drains receive liquid from surrounding areas and by the attached piping, convey the liquid to the storm or sanitary drainage system. Floor drains are primarily

More information

SUNY Genesee Community College JMZ Project No Implementation of Master Plan Projects - Phase 1 Site Improvements

SUNY Genesee Community College JMZ Project No Implementation of Master Plan Projects - Phase 1 Site Improvements PART 1 - GENERAL 1.01 SUMMARY SECTION 334100 STORM UTILITY DRAINAGE PIPING A. Section Includes: 1. Pipe and fittings. 2. Nonpressure transition couplings. 3. Expansion joints and deflection fittings. 4.

More information

ZS880 Linear Shower Drain Installation Instructions

ZS880 Linear Shower Drain Installation Instructions Introduction PATENT PENDING The Zurn ZS880 Stainless Steel Linear Shower Drain incorporates a simple approach to bathroom shower design, when compared to traditional point-drain applications. The linear

More information

EL DORADO COLONIA STREET IMPROVEMENT PROJECT PHASE III IN THE CITY OF EL CENTRO ADDENDUM NO. 02

EL DORADO COLONIA STREET IMPROVEMENT PROJECT PHASE III IN THE CITY OF EL CENTRO ADDENDUM NO. 02 EL DORADO COLONIA STREET IMPROVEMENT PROJECT PHASE III IN THE CITY OF EL CENTRO ADDENDUM NO. 02 Date: April 22, 2009 To: Prospective Bidders/Plan Holders From: Abraham Campos, PE on behalf of City of El

More information

COTTONWOOD IMPROVEMENT DISTRICT SALT LAKE COUNTY SERVICE AREA #3 SOLITUDE IMPROVEMENT DISTRICT TOWN OF ALTA WATERSHED SERVICE LINE SPECIFICATIONS

COTTONWOOD IMPROVEMENT DISTRICT SALT LAKE COUNTY SERVICE AREA #3 SOLITUDE IMPROVEMENT DISTRICT TOWN OF ALTA WATERSHED SERVICE LINE SPECIFICATIONS COTTONWOOD IMPROVEMENT DISTRICT SALT LAKE COUNTY SERVICE AREA #3 SOLITUDE IMPROVEMENT DISTRICT TOWN OF ALTA WATERSHED SERVICE LINE SPECIFICATIONS WATERSHED AREA: The entire area in any canyon above the

More information

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection PERMITS & INSPECTIONS 750 17th Street West Vancouver BC V7V 3T3 westvancouver.ca/permits t: 604-925-7040 f: 604-925-7234

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 02630 - STORM DRAINAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

RUSTIC FIRE PIT SIENNA QUARRY GRAY TAN AUTUMN BLEND.

RUSTIC FIRE PIT SIENNA QUARRY GRAY TAN AUTUMN BLEND. RUSTIC FIRE PIT QUARRY GRAY 198-6235 SIENNA 198-6236 TAN 198-6237 AUTUMN BLEND 198-6238 Approximate Weight: 1565 lbs Approximate Size: x x 1 2 www.midwestmanufacturing.com BELGIAN WALL BLOCKS CONCRETE

More information

Contactor & Recharger

Contactor & Recharger Contactor & Recharger Septic Chambers 2009 Installation Guide Book CULTEC Septic Chambers CULTEC Chambers: The New Standard in Leachfields The CULTEC Contactor and Recharger chambers are the alternative

More information

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated. ZGF Partnership Page 1 of 7 SECTION 33 46 00 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes subdrainage systems for foundations and underslab areas. 1.2 SUBMITTALS A. Product Data: For each type

More information

Design Plans for the "Advantage 6000 Gallon Koi Pond"

Design Plans for the Advantage 6000 Gallon Koi Pond 1 Introduction Today there is a serious problem when it comes to designing and building a quality koi pond. The problem is that few people can agree on how to do it. Most people who decide to build a koi

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Linear Drainage Z886. Perma-Trench. Installation Instructions. 100mm Clear Opening

Linear Drainage Z886. Perma-Trench. Installation Instructions. 100mm Clear Opening Linear Drainage Z886 100mm Clear Opening Perma-Trench Installation Instructions Z886 Tools Required Tape Measure Phillips Head Screwdriver Hammer Utility Knife Marker Cordless Drill Reciprocating Saw Ear

More information

SENTINEL BARRIER - GENERAL INSTALLATION GUIDELINES

SENTINEL BARRIER - GENERAL INSTALLATION GUIDELINES SENTINEL BARRIER - GENERAL INSTALLATION GUIDELINES Safety Precautions in the Excavation of a Sentinel Wedge take all necessary steps to make sure the pit is secured. Follow all OSHA requirements for digging

More information

GBHF Submittal Special Precautions Specifications Installation Application Specific Details

GBHF Submittal Special Precautions Specifications Installation Application Specific Details Submittal Special Precautions Specifications Installation Application Specific Details 68" (1,27 (172 cm) mm 13½" (343 cm) mm) 51½" (1,308 (131 cm) mm) 38" (965 (97 cm) SUBMITTAL 33½" (851 cm) mm) STANDARD:

More information