Variety of uses: Universal Pool Skimmer Cover, Water Main, Valves, Waterfalls & Fountains, Sewer Cleanouts MADE IN USA. Also Available in Gray & Tan
|
|
- Clare Rich
- 6 years ago
- Views:
Transcription
1 MADE IN USA Variety of uses: Universal Pool Skimmer Cover, Water Main, Valves, Waterfalls & Fountains, Sewer Cleanouts Also Available in Gray & Tan Pour-A-Lid is a product of Stetson Development, Inc. For further information call (800) or fax (951) Come visit our website at
2 Pour-A-Lid 201 PAL Tan 201 PAL Grey 201 PAL Clear Now with universal fit and screw down capability 10 Pour-A-Lid Pool Skimmer Cover for New Construction Fits: Hayward 1070, Hayward 1080, Waterway, Sta-Rite, Swimquip, U3, Jacuzzi, American, Pentair/Pacfab 204 PAL Tan 204 PAL Grey Screw down capability 9 Pour-A-Lid Replacement Lid for existing Pool Skimmer Fits: Hayward 1070, Waterways, Sta-Rite, U3, MP Auto Fill 202 PAL Tan 202 PAL Grey 202 PAL Clear 6 Pour-A-Lid Cover Fits: Play Equipment, Sewer Cleanouts, Valves, Water Main Also Available Automatic Water Level System SDI-WF420 Includes a Pour-A-Lid For further information: Call (800) Fax (951) Pour-A-Lid is a product of Stetson Development, Inc. Patent #6,393,771 B1 visit our website at :
3 Stetson Development Inc. ABS Auto Fill Standard Available in 3/8 #3-8ATF 1/2 #1-2ATF Standard pipe thread inlet and free flow outlet Adjustable arm can be used in the vertical or horizontal position Estimated flow rate of 1.5 at 40 PSI.093 orifice Approximate overall length of 7.5 ABS construction Excellent for Ponds, Fountains and MP-Auto Fills For further information contact Mike: Phone (800) Fax (951) Bramble Ct., Lake Elsinore, CA visit our website at
4 ABS Auto Fill Standard 3-8ATF 3-8ATFLA 1-2ATF 1-2ATFLA 3-8ATF 3-8ATFLA 1-2ATF 1-2ATFLA 1-4ATFC 3/8 Auto-Fill 3/8 Auto-Fill with 5 extension 1/2 Auto-Fill 1/2 Auto-Fill with 5 extension 1/4 Auto-Fill with Compression Fitting Swamp Coolers Pool Water Levelers Variety of Uses Fountains Ponds Cooling Towers Live Stock Water Feeders For further information: ABS Auto-Fill is a product of Stetson Development, Inc. Patent Pending Call (800) Fax (951) visit our website at :
5 Pour-A-Lid and Pour-A-Lid Automatic Water Level System are products of Stetson Development, Inc. For further information call (800) or fax (951) Come visit our website at Lid also Available in Gray & Tan
6 Automatic Water Level System Coping Decking Bond Beam Top of bond beam reference level point 1/2 PVC Pipe Over Flow (optional) 1/2 ABS Float Valve Adjustable Float Arm 1 1/2 Equalizer Drawing not to Scale SDI WF 420 PAL Tan SDI WF 420 PAL Grey SDI WF 420 PAL Clear 10 Pour-A-Lid Pool and Pond Automatic Water Level System For further information: Pour-A-Lid is a product of Stetson Development, Inc. Patent #6,393,771 B1 Call (800) Fax (951) visit our website at :
7 Made in USA Pour-A-Drain is a product of Stetson Development, Inc. For further information call (800) or fax (951) Come visit our website at Patent Pending
8 Pour-A-Drain Easy to Install 1. Cut pipe and set top of coupling to finished drain elevation. Make sure coupling is facing up. 2. For best results remove drain insert from coupling use tape or paper to keep drain coupling free of construction debri. 3. Pour concrete or cut stone to finished surface elevation. Fill with stone or concrete. 4. Cut stone or pour concrete into drain cap. For best results tap bottom of drain cap to settle concrete into place. 5. When concrete is cured clean coupling and drain cap. Install drain cap into coupling. DC 401 Tan DC 401 Gray DC 401 Clear 4 SDR35 3 drain pipe / Specifications 4 Round Poly Resin Grate with Universal Fit 3 to 4 Collar Fits: 3 or 4 SDR-35 Drain Pipe 3 Open surface area SQ.IN G.P.M Recommended Load Class A Load at 1-60 PSI For Pedestrians, Bicycles and Wheel Chair Traffic Loads are based on encasing product in Concrete For further information: Call (800) Fax (951) Pour-A-Drain is a product of Stetson Development, Inc. Patent Pending visit our website at :
BRILLIANT WONDERS LED WATERFALL INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED WATERFALLS
R BRILLIANT WONDERS LED WATERFALL INSTALLATION INSTRUCTIONS CMP 25677 SERIES Brilliant Wonders LED WATERFALLS TABLE OF CONTENTS 1 Product Overview....2 1.1. Packing List...2 2 Safety.3 3 Installation Guide.....4
More informationINSTALLATION INSTRUCTIONS CMP SERIES
INSTALLATION INSTRUCTIONS CMP 25677 SERIES 1. PRODUCT OVERVIEW Thank you for choosing our 25677 Series Brilliant Wonders LED Waterfall. This lighted waterfall will add a unique ambiance to your pool or
More informationInground Pool Liners
Inground Pool Liners 20 Mil or 30 Mil Pool Liner ALL SIZES AND STYLES AND PATTERNS AVAILABLE PLEASE CALL FOR MEASUREMENT SHEET AND PRICING Pool Safety Stingl Switch When a blockage occurs it shuts down
More informationInground Pool Liners
Inground Pool Liners 20 Mil or 30 Mil Pool Liner ALL SIZES AND STYLES AND PATTERNS AVAILABLE PLEASE CALL FOR MEASUREMENT SHEET AND PRICING Pool Safety Stingl Switch When a blockage occurs it shuts down
More informationInground Pool Liners
Inground Pool Liners 20 Mil or 30 Mil Pool Liner ALL SIZES AND STYLES AND PATTERNS AVAILABLE PLEASE CALL FOR MEASUREMENT SHEET AND PRICING Pool Safety Stingl Switch When a blockage occurs it shuts down
More informationDrainage and Erosion Control
Drainage and Erosion Control Erosion Control To order Straw Waddle 020897 Straw Waddle 9" x 25 Roll 14 Rolls/ None 140209 Wood Stakes 1" x 2" x 18" 50 Pcs./Bndl. None Straw fiber rolls that control erosion
More informationToll Free Order Line: or Fax: Advantage Leisure Products Ltd. All rights reserved.
Pool Safety Stingl Switch When a blockage occurs it shuts down the pump to prevent injury or death. Works on all single speed pool or spa pumps up to 3 hp. Stock Number: Size: List Price: SR500 Stingl
More informationFiberstars Lighted Laminar Flow Fountains
Fiberstars Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Lighted Laminar Flow Fountain. The maximum lighted
More informationwww.arizonawholesalepoolcontractors.com The Swimming Pool Construction Checklist is designed to give you some guidelines and hints of items to look for while you re building your own pool. It s outline
More informationToll Free Order Line: or Fax: Advantage Leisure Products Ltd. All rights reserved.
Pool Safety Stingl Switch When a blockage occurs it shuts down the pump to prevent injury or death. Works on all single speed pool or spa pumps up to 3 hp. Stock Number: Size: List Price: SR500 Stingl
More informationYOUR SPLASH PAD RESOURCE
1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature
More informationConcrete Answers for Better Living. Plastics
Concrete Answers for Better Living Plastics Leaders in Innovation for Over 40 Years The Mortex Difference Concrete Answers for Better Living For over 40 years, Mortex has been the contractor s choice for
More informationA. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationFLOOR AND AREA DRAINS
Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA
More informationSECTION PLUMBING SPECIALTIES
PART 1 GENERAL 1.1 SCOPE SECTION 22 20 00 PLUMBING SPECIALTIES A. Work consists of all plumbing work indicated on drawings and specified herein. B. Also included are all fees and permits for installation
More informationSTANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING
STANDARD CONSTRUCTION DETAILS REVISED MARCH 2018 GENERAL NOTES EMBEDMENT DETAILS EMBEDMENT DETAILS TWO-WAY CLEANOUT - EXISTING LATERAL TWO-WAY CLEANOUT - NEW CONSTRUCTION TYPICAL SEWER HOUSE SERVICE CONNECTION
More informationCHAPTER 12 INSTALLATION OF UTILITIES AND OTHER SYSTEMS TABLE OF CONTENTS
CHAPTER 12 INSTALLATION OF UTILITIES AND OTHER SYSTEMS TABLE OF CONTENTS Section Title Page 12.1 General... 12-1 12.2 Design Standards... 12-1 12.2.1 General Requirements...12-1 12.2.2 Minimum Depth...12-1
More informationA. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.
PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationPHASE 1 Foundation & Drainage New Construction Phased Inspection Report John & Mary Doe 5237 Clinton Street, Denver, CO 80238
PHASE 1 Foundation & Drainage New Construction Phased Inspection Report John & Mary Doe 5237 Clinton Street, Denver, CO 80238 PHASE 1 Foundation & Drainage New Construction Phased Inspection Report Buyers
More informationCITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER
CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER WATER MAIN 1. All open cut water main shall be polyvinyl chloride plastic (PVC) pressure pipe per AWWA specification
More informationD. Encase exterior cleanouts in concrete with access cover installed flush with grade.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.
Wastewater Sampling Port Technical Data Submittal Special Precautions Specifications Installation 16½" (31.8 (41.9 cm) 8" (20.3 cm) -L -O SUBMITTAL STANDARD: 4" plain end inlet/outlet Highway traffic load
More informationInstallation Instructions
Installation Instructions (for part no:s HD100SN, HD100N, HD100LAK, HD1001SCS, HD1001CS, HD1001SLS, HD1001LS, HD101LS) s - Pool Installation (Part Nos: HD100SN Collar Weir or HD100N Flap Weir & HD100LAK)
More information5.0 ENDURA GREASE MANAGEMENT. Endura Grease Interceptors with Spigot format Flow Control Devices.
GREASE MANAGEMENT 5.0 ENDURA GREASE MANAGEMENT New! With Spigot Format Flow Control Devices Diffuser Baffle supplied only with 35/50 GPM models Canplas is pleased to announce the extension of our Endura
More informationPLASTIC FITTINGS Avenue Edmonton, AB Canada T6E 5Z7. Toll Free: Phone: (780) Fax: (780)
9333 45 Avenue Edmonton, AB Toll Free: 1-800-272-9693 Phone: (780) 436-1930 Fax: (780) 435-4849 info@can-con.com TABLE OF CONTENTS PLASTIC FITTINGS POLYETHYLENE PIPE...- 1 - SERVICE RISERS... - 3 - TRANSITION
More informationA. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.
SECTION 22 13 00 FACILITY SANITARY SEWERAGE PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationSECTION SANITARY UTILITY SEWERAGE PIPING
SECTION 33 31 00 SANITARY UTILITY SEWERAGE PIPING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Sanitary sewer pipe and fittings. 2. Underground pipe markers. 3. Connection to existing manholes. 4.
More informationSTORM DRAINAGE CHAPTER 11
CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,
More informationSTORM DRAINAGE CHAPTER 11
CHAPTER STORM DRAINAGE SECTION 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage, except in one- and two-family dwellings.
More informationSeries. 6 Wide POLYCAST 600 SP Polymer Concrete Trench Drain Kit
TPC600SP Complete Kit TPC600SP Cut Sheet Polycast 600 6 Wide POLYCAST 600 SP Polymer Concrete Trench Drain Kit New Polymer Concrete Trench Drain Complete Kit 6 Inch Wide - C Class Spiral Decorative Grate
More informationROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
More informationTYPICAL INSTALLATION INSTRUCTIONS
TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect
More information200 Series In-Slab Pool Fittings
230 Series nti-vortex Plate 2-2 231 Series Sump 2-3 234 Series Sump 2-4 236 Series Sump 2-5 253 Series Overflow 2-6 255 Series Overflow/Drain 2-7 261 Series Vacuum Fitting 2-8 263 Series Eyeball Fitting
More informationProject Location: Various, Anywhere, PA Bid Date: 7/16/ Rock Construction Entrance
To: Project Name: Bidding Company Site Work Project Contact: Address: Various Phone: Fax: Bid Number: Project Location: Various, Anywhere, PA Bid Date: 7/16/2014 Clarifications: This takeoff does not include
More informationPage 1- MAGNEIS PANEL POOLS 2- BETON BLOCK POOLS
390 Page - MAGNEIS PANEL POOLS - BETON BLOCK POOLS 39 395 39 Prefabricated Swimming Pools - MAGNELIS PANEL MAGNELIS PANEL is a latest addition of Aqua SpA in the prefabricated structures field. This is
More informationPOLYLOK / ZABEL PRODUCT BROCHURE v.3
POLYLOK / ZABEL PRODUCT BROCHURE v.3 Heavy Duty Trench Drain (Black, Grey, Green, Tan & Ductile ) 3, 4, 6, 8, 10 & 12 Black & Green Pipe s Flow Gate 12 Polylok & Pipe Adapter Ring x3 / Pan x2 & 24 x2 X-Chairs
More informationProduct Manual PV1700 / PV1800 / PV2300 / PV18EXT / PV23EXT / SP1600 / SP1900 / SP2600 / SP
PF Product Manual PV1700 / PV1800 / PV2300 / PV18EXT / PV23EXT / SP1600 / SP1900 / SP2600 / SP3800 1.330.274.8317 www.atlanticwatergardens.com Table of Contents Eco-Blox Reservoirs... 2 Gravel-Filled Reservoirs...3
More informationETL listed for installations within 5 ft. (1.5M) of outer edge of water
Color Light Stream Lighted Rain Waterfall Installation Manual Part number Description CLSRW24-8 Color Light Stream Lighted Rain Waterfall 24 CLSRW36-8 Color Light Stream Lighted Rain Waterfall 36 CLSRW48-8
More informationUniversity of Central Florida Main Campus. Domestic Water. Service and Meter Installations Requirements. Issued January 26 th, 2017.
University of Central Florida Main Campus Domestic Water Service and Meter Installations Requirements Issued January 26 th, 2017 1 P a g e Table of Contents 1. GENERAL INFORMATION... 3 2. DEFINITIONS...
More informationFIELD GUIDE FOR MILLENNIUM MOUNDS CLERMONT CO. GENERAL HEALTH DISTRICT 2010
FIELD GUIDE FOR MILLENNIUM MOUNDS CLERMONT CO. GENERAL HEALTH DISTRICT 2010 DIMENSIONS BETWEEN DRAINS SINGLE LENGTH MOUND 2 BEDROOM 98 X 20 3 BEDROOM 139 X 20 4 BEDROOM 184 X 20 HALF STRUCTURE MOUND 2
More information0.75 " transparent hose w/ valve for head measurements fixed to screws 20 MIL PVC liner. 6" gate valve
0.75 " transparent hose w/ valve for head measurements fixed to screws 250x1000 RC beam 6" gate valve Foundation preparation in accordance with technical specifications and as approved by engineer 25 cm
More informationRADIAL FLOW SETTLER 60 CONE (RFS-60)
RADIAL FLOW SETTLER 60 CONE (RFS-60) INSTALLATION AND OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 2 CUSTOMER SERVICE / TECHNICAL SUPPORT If you
More informationPre-Sloped Drain System
SportsEdge PolyDrain Pre-Sloped Drain System www.sportsedge.com Quality. Safety. Versatility. Aesthetics. 2 PolyDrain FORMULA www.sportsedge.com ABT, Inc. manufactures PolyDrain trench drains; the standard
More informationHow To Construct a Ferro Cement Tank
How To Construct a Ferro Cement Tank Be Advised The following power point presentation assumes that individuals using it to construct ferro-cement tanks have a basic knowledge of geometry and calculating
More information1. Required Minimum Flow:
SECTION 6 6. 6.01 General The City of Castle Rock Water System Minimum Standards and Specifications are minimum base level performance, design, and construction standards used to maintain uniformity of
More information1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.
PAGE 334000-1 SECTION 334000 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,
More informationTECHNICAL SPECIAL PROVISION FOR FINANCIAL PROJECT ID:
TECHNICAL SPECIAL PROVISION FOR 1001 WATER DISTRIBUTION SYSTEM FINANCIAL PROJECT ID: 200105-7-52-01 The official record of this Technical Special Provision is the electronic file signed and sealed under
More informationNever ones to rest on our laurels, at NDS we ve taken our popular, easy-to-install Pro Series Channel Drain and made it even better.
MODuLAr CHANNEL DrAiNS Patented PrO SEriES CHANNEL DrAiNS HAvE you SEEN THE NEW AND improved PrO SEriES CHANNEL DrAiN? Never ones to rest on our laurels, at NDS we ve taken our popular, easy-to-install
More informationGrease Management. EnduraGreaseManagement.com. Rethinking Grease Interception
Grease Management EnduraGreaseManagement.com Rethinking Grease Interception Endura has the right stuff The Right Reason Guided by a philosophy of minimizing downstream toxic waste, Endura engineers have
More informationSUPPLEMENTAL SPECIFICATIONS AND DRAWINGS TO THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION TABLE OF CONTENTS
PREFACE AND CITY ENGINEER S LETTER INDEX OF STANDARD DRAWINGS DIVISION 100 GENERAL CONDITIONS ARTICLE 1 DEFINITIONS AND TERMINOLOGY 1.01 Defined Terms ARTICLE 2 PRELIMINARY MATTERS 2.01 Delivery of Bonds
More informationSURFACE DRAINAGE SYSTEMS
SURFACE DRAINAGE SYSTEMS Plumbing & Drainage Solutions pg 1 pg 3 130mm channel system shallow channel system CONTENTS LOADING CLASS LIGHT TRUCK CAR Light weight commercial vehicle driving at no more than
More informationQUOTE Quote Process City Of Taylor
PROJECT SPECIFICATIONS QUOTE Quote Process City Of Taylor Budget & Finance Dept. Purchasing Manager: RMM 23555 Goddard Road Taylor, MI 48180 734-374-1459 The City of Taylor Central Purchasing Division
More informationSECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS
SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY Section Includes: 1. Pipe and fittings. 2. Drain Basin. 3. De-chlorination tablet feeder. 4. Non-pressure transition couplings.
More informationSPECIAL SPECIFICATION 3504 Septic Tank System
1993 Specifications CSJ s 3136-01-126, etc. & 0683-01-070, etc. SPECIAL SPECIFICATION 3504 Septic Tank System 1. Description. This Item shall govern for all materials, equipment and labor necessary for
More informationInstallation Manual. Read the complete installation manual and Owners Manual before beginning the installation.
Installation Manual Read the complete installation manual and Owners Manual before beginning the installation. 1. Sizing the System Size the system using the Simplified Sizing Guide For Solar Pool Heaters.
More informationSYSTEMS LTD. Leader in Linear Drain Solutions. A Publication of. Page 1. Randy Franzke. Cellar Master Supplies. Phone:
Page 1 SYSTEMS LTD. Leader in Linear Drain Solutions www.slotdrainsystems.com A Publication of Randy Franzke Cellar Master Supplies Phone: 707-307-8250 http://cellarmastersupplies.com Table of Contents
More informationPART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT]
PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT] A. - General. B. - Streets. C. - Stormwater drainage system. D. - Water
More informationolor Match POOL FITTINGS, INC. Blending Beauty & Function
olor Match POOL FITTINGS, INC. Blending Beauty & Function PEBBLE TOP DRAIN Patent # s 6,209,586 / 6,340,035 / 6,557,588 Additional patents pending 20-INCH VGB UNBLOCKABLE CONVERTIBLE DRAIN TWO DRAINS IN
More informationA. This Section includes the following sanitary drainage piping specialties:
Page 221319-1 SECTION 221319 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSkimmers. The Industry Standard for Performance and Reliability. For All Types of Inground and Aboveground Swimming Pools
Skimmers The Industry Standard for Performance and Reliability For All Types of Inground and Aboveground Swimming Pools Admiral S15 Admiral Skimmers Built tough for reliable service. Admiral skimmers offer
More informationCITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413
Page: 1 of 5 CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413 COMMERCIAL/RESIDENTIAL UTILITY PLAN COMPLETENESS CHECK LIST Updated
More informationWelcome: What is U-Drain? Drain Materials. Flow
Welcome: Thank you for looking into the U-Drain floor drain system. This paper will explore the functional features of the U-Drain and why it is superior to other grated systems in the marketplace. We
More informationProper Construction of detention and sediment basins and their conversions
Proper Construction of detention and sediment basins and their conversions By Chris Droste, CESCO Senior Erosion Control Specialist Westmoreland Conservation District Discussed topics Pond embankment construction
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 33 3400 STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION HYDRONIC PIPING
PART 1 GENERAL 1.1 REFERENCES SECTION 23 21 13 HYDRONIC PIPING A. ANSI/ASME SEC 9: Welding and Brazing Qualifications B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300 C. ANSI/ASME
More informationNOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST
NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INSTALL MANHOLE LIDS FLUSH WITH EXISTING GROUND SURFACE.
More informationFS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)
Wastewater Flow Distributor Technical Data Submittal Special Precautions Specifications Installation 24½" (62.2 cm) 12½" (31.8 cm) 24½" (62.2 cm) (30.5 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet
More informationFERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS
IRRIGATION EQUIPMENT LTD. FERTILIZER T A N K S SERIES 6000 APPLICATIONS Designed specifically for fertigation in agriculture Simple, efficient and trouble free operation. Standard models apply fertilizer
More informationPOLYCAST Trench Drain Systems
POLYCAST 3621 Industrial Park Drive Lenoir City, TN 37771 Phone: 800-346-3061 Fax: 865-986-0585 Email: hpsliterature@hubbell.com www.polycastdrain.com POLYCAST Trench Drain Systems FP800 Series Specification
More informationSECTION FACILITY SANITARY SEWERS
SECTION 22 13 13 FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION HYDRONIC PIPING
PART 1 GENERAL 1.1 REFERENCES SECTION 23 21 13 HYDRONIC PIPING A. ASME BPVC Section IX - Welding and Brazing Qualifications B. ASME B16.3 - Malleable Iron Threaded Fittings Classes 150 and 300 C. ASME
More informationDEPARTMENT OF PUBLIC UTILITIES
DEPARTMENT OF PUBLIC UTILITIES Orangeburg, South Carolina PLUMBING RULES AND REGULATIONS TABLE OF CONTENTS Section Page 1.0 General... 1 1.1 Definitions... 1 2.0 Water Distribution System... 3 2.1 Water
More informationSpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )
SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 ) WARNING - When unpacking SpaVault, DO NOT discard styrofoam pieces, these are not packaging materials. Step 1 Excavation Important:
More informationSection 403. DRAINAGE STRUCTURES
403.01 Section 403. DRAINAGE STRUCTURES 403.01. Description. This work consists of adjusting, constructing, or temporarily lowering drainage structures and cleaning existing drainage structures and leads
More informationCHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION.
Standard Drawings Index NOTE: The specifications for materials and workmanship shall conform to the latest edition or the "Standard Specifications for Public Works Construction" published by the North
More informationCity of Fort Walton Beach Engineering Standards Manual November City of Fort Walton Beach Engineering Standards Manual
City of Fort Walton Beach Manual TABLE OF CONTE SECTION 1.00 INTRODUCTION... 3 SECTION 2.00 POLICY... 3 SECTION 3.00 - EROSION AND SEDIMENTATION CONTROL... 3 EROSION AND SEDIMENTATION CONTROL STANDARD
More informationHi-Cap Slotted Drainage System Surface Drainage
Hi-Cap Slotted Drainage System Surface Drainage Hi-Cap Slotted Drainage System The Zurn Z888 Hi-Cap is a modular slotted drain system constructed from linear low-density polyethylene and is equivalent
More informationStainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.
Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities. Whether it is new construction, renovation or operation,
More informationYAKIMA COUNTY, WASHINGTON. Special Provisions For Water Main Construction
YAKIMA COUNTY, WASHINGTON Special Provisions For Water Main Construction The 2014 Standard Specifications for Road, Bridge, and Municipal Construction as prepared by the Washington State Department of
More informationDIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1
DIVISION 3: SEWER 3.1 DESIGN CRITERIA A. APPLICABILITY 1. These Design Standards shall govern all construction and upgrading of public sanitary sewer facilities in the City of Dundee and applicable work
More informationAPPENDIX B STANDARD CONSTRUCTION DRAWING NOTES
APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES B-1 General Notes: SACWSD Standard Construction Drawing Notes 1. No work shall begin on any water or wastewater construction project until the construction
More informationASHWELL FIRE PIT SIENNA QUARRY GRAY TAN AUTUMN BLEND. Plan Date: June 2016
ASHWELL FIRE PIT QUARRY GRAY 198-620 SIENNA 198-621 TAN 198-622 AUTUMN BLEND 198-623 Plan Date: June 2016 Approximate Weight: 1,300 lbs Approximate Size: 4 2 Ext. 3 0 Intr. 1 2 H www.midwestmanufacturing.com
More informationWelcome: What is U Drain? Drain Materials. Cost Comparisons
Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We
More information4.28 Underground Detention
4.28 Underground Detention Detention Structural Stormwater Control Description: Detention storage located in underground tanks or vaults designed to provide water quantity control through detention and/or
More informationFLOOR DRAINS GENERAL INFORMATION
FLOOR DRAINS 11 FLOOR DRAINS GENERAL INFORMATION All floor drains and rodding eyes are made from stainless steel V2A (AISI 304) or V4A (AISI 316). The floor drain type depends on the load, amount of drained
More information1 ½
HOW TO SELECT A FLOOR DRAIN Floor and area drains receive liquid from surrounding areas and by the attached piping, convey the liquid to the storm or sanitary drainage system. Floor drains are primarily
More informationSUNY Genesee Community College JMZ Project No Implementation of Master Plan Projects - Phase 1 Site Improvements
PART 1 - GENERAL 1.01 SUMMARY SECTION 334100 STORM UTILITY DRAINAGE PIPING A. Section Includes: 1. Pipe and fittings. 2. Nonpressure transition couplings. 3. Expansion joints and deflection fittings. 4.
More informationZS880 Linear Shower Drain Installation Instructions
Introduction PATENT PENDING The Zurn ZS880 Stainless Steel Linear Shower Drain incorporates a simple approach to bathroom shower design, when compared to traditional point-drain applications. The linear
More informationEL DORADO COLONIA STREET IMPROVEMENT PROJECT PHASE III IN THE CITY OF EL CENTRO ADDENDUM NO. 02
EL DORADO COLONIA STREET IMPROVEMENT PROJECT PHASE III IN THE CITY OF EL CENTRO ADDENDUM NO. 02 Date: April 22, 2009 To: Prospective Bidders/Plan Holders From: Abraham Campos, PE on behalf of City of El
More informationCOTTONWOOD IMPROVEMENT DISTRICT SALT LAKE COUNTY SERVICE AREA #3 SOLITUDE IMPROVEMENT DISTRICT TOWN OF ALTA WATERSHED SERVICE LINE SPECIFICATIONS
COTTONWOOD IMPROVEMENT DISTRICT SALT LAKE COUNTY SERVICE AREA #3 SOLITUDE IMPROVEMENT DISTRICT TOWN OF ALTA WATERSHED SERVICE LINE SPECIFICATIONS WATERSHED AREA: The entire area in any canyon above the
More informationEFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection
EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection PERMITS & INSPECTIONS 750 17th Street West Vancouver BC V7V 3T3 westvancouver.ca/permits t: 604-925-7040 f: 604-925-7234
More informationPASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017
SECTION 02630 - STORM DRAINAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationRUSTIC FIRE PIT SIENNA QUARRY GRAY TAN AUTUMN BLEND.
RUSTIC FIRE PIT QUARRY GRAY 198-6235 SIENNA 198-6236 TAN 198-6237 AUTUMN BLEND 198-6238 Approximate Weight: 1565 lbs Approximate Size: x x 1 2 www.midwestmanufacturing.com BELGIAN WALL BLOCKS CONCRETE
More informationContactor & Recharger
Contactor & Recharger Septic Chambers 2009 Installation Guide Book CULTEC Septic Chambers CULTEC Chambers: The New Standard in Leachfields The CULTEC Contactor and Recharger chambers are the alternative
More informationA. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.
ZGF Partnership Page 1 of 7 SECTION 33 46 00 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes subdrainage systems for foundations and underslab areas. 1.2 SUBMITTALS A. Product Data: For each type
More informationDesign Plans for the "Advantage 6000 Gallon Koi Pond"
1 Introduction Today there is a serious problem when it comes to designing and building a quality koi pond. The problem is that few people can agree on how to do it. Most people who decide to build a koi
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 22 1319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationLinear Drainage Z886. Perma-Trench. Installation Instructions. 100mm Clear Opening
Linear Drainage Z886 100mm Clear Opening Perma-Trench Installation Instructions Z886 Tools Required Tape Measure Phillips Head Screwdriver Hammer Utility Knife Marker Cordless Drill Reciprocating Saw Ear
More informationSENTINEL BARRIER - GENERAL INSTALLATION GUIDELINES
SENTINEL BARRIER - GENERAL INSTALLATION GUIDELINES Safety Precautions in the Excavation of a Sentinel Wedge take all necessary steps to make sure the pit is secured. Follow all OSHA requirements for digging
More informationGBHF Submittal Special Precautions Specifications Installation Application Specific Details
Submittal Special Precautions Specifications Installation Application Specific Details 68" (1,27 (172 cm) mm 13½" (343 cm) mm) 51½" (1,308 (131 cm) mm) 38" (965 (97 cm) SUBMITTAL 33½" (851 cm) mm) STANDARD:
More information