Smart Aggregates Containing Piezoceramics: Fabrication. and Applications

Size: px
Start display at page:

Download "Smart Aggregates Containing Piezoceramics: Fabrication. and Applications"

Transcription

1 Smart Aggregates Containing Piezoceramics: Fabrication and Applications 1, 2, Chris Choi 1, 3 1. NSF- REU Researcher for the Department of Mechanical Engineering, University of Houston, USA 2. Undergraduate Student; Department of Civil Engineering, University of Maine 3. Undergraduate Student; Department of Mechanical Engineering, University of Houston Graduate Student Advisors: Hai Chang Gu PhD. Student; Department of Mechanical Engineering, University of Houston Claudio Olmi PhD. Student; Department of Mechanical Engineering, University of Houston Faculty Advisors: Dr. Gangbing Song; Faculty-in-charge, Smart Materials and Structures Laboratory, University of Houston Dr. Yi-Lung Mo; Professor of Civil Engineering REU Sponsor, University of Houston I. Abstract The piezoelectric effect is a useful way to monitor the health of cast concrete. PZT patches can be embedded in small concrete blocks called a smart aggregate then cast in larger structures for concrete strength monitoring. They are designed to monitor the early age concrete strength development, impact detection and structural health. Piezoceramic materials exhibit the phenomenon of piezoelectricity. Piezoelectricity describes the event of generating an electric charge in a material when subjecting it to mechanical stress, and conversely, generating a mechanical strain in response to an applied electric field. PZT is an acronym for Lead Zirconate Titanate, which is a commonly used piezoelectric ceramic material and is the piezoelectric ceramic material used in this project. Smart aggregates are designed for civil structures such as buildings and bridges. II. Introduction Concrete is such a widely used building material around the world, it is important to monitor its health to prevent disaster. The idea of imbedding PZT patches in concrete is still relatively new. One goal in this research is to continue the study of the effectiveness of smart aggregates. Page 1 of 11

2 PZT patches can be an effective way to measure concrete health. However, the lack of mass production techniques makes it hard to be installed in numerous structures. Another goal of this project is to construct a reusable form for casting smart aggregates for their use in testing. Also we plan to test the strength properties of the smart aggregates and their effect on overall structure strength. In addition, we will explore some new piezoelectric smart aggregate techniques, 3D sensors and protected sensors with RFI Shielding. III. Smart Aggregate Construction Our Piezoelectric material for this project was Lead Zirconate Titanate (PZT). For this research, we cut 10-by-10 square millimeter patches of PZT from a large wafer. These patches were then soldered to a 24/2 (24 American Wire Gauge (AWG), 2 Conductors) shielded communication cable that was connected on the other end to a BNC connecter for computer connection for instruments such as an oscilloscope. We decided to use common PVC pipe caps as our reusable molds to cast the smart aggregate. The caps are approximately 1-1/2 in diameter and 2 in depth. We were able to purchase these at a local hardware store. The standard mode size would be easy to duplicate for mass production. A 1/8 diameter hole was drilled in the bottom of the PVC pipe cap and a custom-made circular aluminum plate was fabricated and placed in the pipe cap. The idea was to push the concrete out after it had been without destroying the mold and allowing the mold to be used again. However the concrete had a tendency to stick to the walls of the pipe cap and removal became quite difficult. Later we used motor oil when casting to help loosing the concrete but removal was still difficult. Future research will need to be done to determine an easier mold removal strategy. To insert the wire with the PZT chip on the end, a small notch was cut in the side of the pipe cap. The wire was placed in the notch with the PZT chip inside the pipe and concrete was poured in, filling the inside of the pipe cap. The smart aggregates were left to harden for at least 24 hours. All of our smart aggregates were cast with the concrete mix specified in Table 1. A schematic of the smart aggregate mold is shown in Figure 1. See Figures 3-8 for a pictorial look of making smart aggregates. Subsequent to preparing our first smart aggregates we monitored their capacitance for the first 5 days after casting (see graph Figure 2). At first, the capacitance was erratic but it eventually leveled off to around 6 nano-farads (nf). The optimal capacitance of the PZT patches is six nano-farads. All of our piezoelectric patches were designed with a capacitance between nano-farads (nf). Page 2 of 11

3 Figure 1 - Schematic of location and position of PZT patch inside pipe-cap for concrete casting C a p a c it a n c e v s. T im e Capacitance (nf) A 1 B 1 C E la p s e d T im e ( M in ) Figure 2 Capacitance of PZT patches after cast in smart aggregate Page 3 of 11

4 Figure 3 Cutting the PZT patch from a larger wafer Figure 4 Soldering the 24/2 shielded connection cable to the PZT patch Figure 5 Cable after the BNC connector has been soldered to other end of cable Figure 6 Waterproofing PZT patch Figure 7- Patch and mold before concrete poring Page 4 of 11

5 After we had made over twenty regular smart aggregates (one PZT chip, concrete only), we then constructed 3D smart aggregates and smart aggregates with RFI Shielding. We created the three dimensional (3D) smart aggregate by cutting three slots in the pipe cap each 90 degrees apart (see figure 9). The PZT patches were each put in three different ways to represent three different planes [x-y, y-z, and x- z]. These sensors can measure waves coming from all different angles. Conversely, the 3D smart aggregates are much harder to construct because of the amount of work keeping the Figure 8- Concrete poured in to the mold angles lined up correctly during casting. The other new mart aggregate we made was an RFI shielded aggregate. Using 100-mesh copper with a.0022 wire diameter the smart aggregate is designed to block radio frequency interference (RFI) that could impede the sensors ability to communicate with other sensors during health monitoring (see figure 10). Setup for creating the shielded aggregate is the same as with regular smart aggregate except before concrete pouring the mesh is lined against the pipe cap walls and on the bottom against the aluminum plate. After the concrete is poured and fills the pipe cap an additional piece of copper wire mesh is placed on the top of the concrete and the entire aggregate hardens into one structure. xz-plane yz-plane xy-plane Figure 9 Diagram of 3D smart aggregate y z x Figure 10 Cut RFI shielding copper mesh before inserted in to mold Page 5 of 11

6 Regular w/ UH logo Engraved 3-D RFI Shielded IV. Testing Procedure Figure 12 Location of smart aggregate in a 6 diameter 12 tall cylinder Figure 11 Types of smart aggregate made A. Experimental Setup With the first batch of smart aggregates we constructed two SA cylinders, one with normal concrete and one with self-compacting concrete, each with two smart aggregates. In addition, we made four cylinders without smart aggregates. Each cylinder mold is six inches in diameter and twelve inches in height. Two holes are drilled in the side of the mold at four inches and eight inches in height for the BNC connectors and wire to go through (see Figure 12). Table 1: Mix Proportions for Smart Aggregate Type III Cement lbs Fine Aggragte lbs Water lbs BASF Superplasicsizer 3 grams Total: 2.5 lbs Table 2: Mix Proportions for Concrete Cylinders Cement (Type 1/2) 28 lbs Sand (Unsifted) 74 lbs Coarse Aggregate 82 lbs Water 17 lbs Total (Approx.): 200 lbs To make a cylinder with smart aggregate the concrete must be poured in three stages. First, the concrete is poured to the four inch mark and one smart aggregate is placed horizontally in the concrete with the wire through the drilled hole. At this point if the concrete is not self compacting the mix is prodded 25 times with a rod before the next part is poured in. When prodding the concrete we try not to touch the smart aggregate to avoid tilting of the aggregate. Then, another four inches of concrete is poured on top of the first smart aggregate. The second smart aggregate is placed in the same manner as the first one with prodding if necessary. Finally, the rest of the concrete is poured to fill out the cylinder. Page 6 of 11

7 With our first batch we were not able to get any structural data for the cylinders containing the smart aggregates, due to a testing failure. We then cast six more cylinders; three with smart aggregates (two smart aggregates in each cylinder, one as a sensor and one as an actuator) and three without smart aggregates using the 200 lb. mix specifications outlined in Table 2, again with each cylinder weighing 30 lbs. B. Results We allowed the cylinders to harden until Day 10 when we broke them out of the molds and capped them with pipe capper. The cylinders were labeled cylinders 1-3 without smart aggregate and cylinders 1-3 with smart aggregate. We tested Cylinder 1 without smart aggregate on Day 13 and planned to test the rest on that day too, however the strain gauge broke and we had to wait for a replacement. We were able to test the remainder of the cylinders on Day 18. We performed a stress-strain test on all the cylinders except Cylinder 3 with smart aggregate which was tested in compression only. The results of the test are shown in Table 3. The cylinders were tested on the Universal Compression Testing Machine with a steady load rate of 500 lbs/sec. We computed the stress and the strain by using the formulas in equations 1 and 2 respectively. The stress-strain curves for the four cylinders tested using the stress-strain control mode on Day 18 can be found in Figures Load Load Load Stress = = = 2 2 (1) Surface Area d 6 π π 4 4 Deflection Deflection Strain = = (2) Original Length 16 The strength of the Concrete can be scaled to the 28 day standard using the time-strength equation for concrete proposed by committee 209 of the American Concrete Institute: ' where c ( t) ' ' t f c ( t) = fc(28) (3) t f is the compressive strength at time t, t is the age of concrete in days and ' f c(28) is the concrete compressive strength at 28 days. The scaled results using equation 3 are shown in Table 4. Page 7 of 11

8 Table 3: Summary of tested cylinders (Strength at time of testing) Cylinders Without Smart Aggregate Cylinders With Smart Aggregate Cylinder # Days Ultimate Strength (KSI) Cylinder # Days Ultimate Strength (KSI) Average 3.66 Average 3.80 Table 4: Summary of tested cylinders (Scaled to 28 day standard) Cylinders Without Smart Aggregate Cylinders With Smart Aggregate Cylinder # Days Ultimate Strength (KSI) Cylinder # Days Ultimate Strength (KSI) Average 4.03 Average 4.07 Figure 13 Stress Strain curve of cylinder 2 without smart aggregate Stress Strain Curve Stress (KSI) Strain Page 8 of 11

9 Figure 14 Stress Strain curve of cylinder 3 without smart aggregate Stress Strain Curve Stress (KSI) Strain Figure 15 Stress Strain curve of cylinder 1 with smart aggregate Stress Strain Curve Stress (KSI) Strain Page 9 of 11

10 Figure 16 Stress Strain curve of cylinder 2 with smart aggregate Stress - Strain Curve Stress (KSI) Strain Figure 17 Stress Strain Curves for all cylinders Tested on day 18 in stress-strain mode Stress Strain Curves for both Specimens NC 2 NC 3 SA 1 SA Strain Page 10 of 11

11 VI. Conclusions and Future Work Our research concluded that it is possible to build smart aggregates cheaply and efficiently. We also showed it is possible to make smart aggregates with 3D sensors and smart aggregates with RFI shielding. Our testing showed that the smart aggregates imbedded in the concrete cylinders had no negative effect on the ultimate strength of those cylinders compared to the cylinders without smart aggregate. Future research efforts will include the improvement of the smart aggregate molds, particularly the smart aggregate removal from the molds. In addition, more research should be done to determine the sensor s accuracy in the concrete and their use in larger more realistic structures. Also, work will need to done to determine the feasibility of installing 3-D smart aggregate in cylinders and structures along with the effectiveness of the RFI shielding. VII. Acknowledgments The research study described herein was sponsored by the National Science Foundation under the Award No. EEC The opinions expressed in this study are those of the authors and do not necessarily reflect the views of the sponsor. VIII. References 1. Gu, H, G Song, H Dhonde, Y L. Mo, and S Yan. "Concrete Early-Age Strength Monitoring." Smart Materials and Structures 15 (2006): Song, Gangbing. "Basics About Piezoceramic Materials." Intelligent Structural System. University of Houston: Department of Mechanical Engineering. 3. Song, Gangbing, Haichang Gu, and Yi-Lung Mo. Smart Aggregate. 4th China-Japan-US Symposium on Structural Control and Monitoring, 16 Oct. 2006, University of Houston. 4. Song, G., Gu, H. and Mo, Y.L., Smart Aggregates: a Distributed Intelligent Multi-purpose Sensor Network (DIMSN) for Civil Structures, Proceedings of the 2007 IEEE International Conference on Networking, Sensing and Control, London, UK, April, 2007: Page 11 of 11

CHAPTER III METHODS AND MATERIALS

CHAPTER III METHODS AND MATERIALS CHAPTER III METHODS AND MATERIALS 3.1: Tensile Tests 3.1.1: Introduction The first phase of testing for the experimental program, was to conduct tensile tests of No. 4, No. 5, and No. 6 nominal diameter

More information

Corrosion Detection in Reinforced Concrete Beams Using Piezoceramics

Corrosion Detection in Reinforced Concrete Beams Using Piezoceramics Corrosion Detection in Reinforced Concrete Beams Using Piezoceramics Shainur Ahsan, REU Student Dr. Haichang Gu, Post-Doc Mentor Dr. Gangbing Song, Faculty Mentor Department of Civil and Environmental

More information

Softening Coefficients for Prestressed Steel Fiber Reinforced Concrete. Prestressed Steel Fiber Reinforced Concrete in Tension.

Softening Coefficients for Prestressed Steel Fiber Reinforced Concrete. Prestressed Steel Fiber Reinforced Concrete in Tension. Constitutive Relationships of Prestressed Steel Fiber Reinforced Concrete in Tension Justin Mickey Softening Coefficients for Prestressed Steel Fiber Reinforced Concrete Thomas Kelleher NSF REU Summer

More information

Geo-Institute. Competition Rules for the National GeoWall

Geo-Institute. Competition Rules for the National GeoWall The Geo-Institute of the American Society of Civil Engineers Presents Competition Rules for the National GeoWall Held During International Foundations Conference and Equipment Expo (IFCEE) 2018 Important

More information

SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket

SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket 1993 Specifications CSJ 0331-04-045 SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket 1. Description. This Item shall govern for the furnishing, installing and energizing a sacrificial

More information

DETERMINATION OF WORKABILITY OF FRESH CONCRETE BY SLUMP TEST

DETERMINATION OF WORKABILITY OF FRESH CONCRETE BY SLUMP TEST DETERMINATION OF WORKABILITY OF FRESH CONCRETE BY SLUMP TEST Aim: To determine the workability of concrete by Slump test as per IS : 1199-1959 Mould - in the form of the frustum of a cone having the following

More information

CONCRETE WALL FABRICATION BY CONTOUR CRAFTING

CONCRETE WALL FABRICATION BY CONTOUR CRAFTING CONCRETE WALL FABRICATION BY CONTOUR CRAFTING Dooil Hwang and Behrokh Khoshnevis Daniel J. Epstein Department of Industrial & Systems Engineering University of Southern California, Los Angeles, CA 90089

More information

Evaluation of the Orientation of 90 and 180 Reinforcing Bar Hooks in Wide Members

Evaluation of the Orientation of 90 and 180 Reinforcing Bar Hooks in Wide Members Research Note Research Note RN-2009-2 Evaluation of the Orientation of 90 and 180 Reinforcing Bar Hooks in Wide Members Introduction Longitudinal reinforcing steel bars in flexural members are often developed

More information

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES Handholes and pulling vaults perform several important functions: Provide drainage for the conduit system so that freezing water does not damage the conduit or wires. Provide a location for bending the

More information

Design of Rigid Pavements

Design of Rigid Pavements Traffic and Highway Engineering (ІІ) CVL 4324 Chapter 20 Design of Rigid Pavements Dr. Sari Abusharar Assistant Professor Civil Engineering Department Faculty of Applied Engineering and Urban Planning

More information

Comparison of Prefabricated Cage System with Existing Reinforcement Methods in Concrete Columns

Comparison of Prefabricated Cage System with Existing Reinforcement Methods in Concrete Columns Comparison of Prefabricated Cage System with Existing Reinforcement Methods in Concrete Columns A Thesis Presented in Partial Fulfillment of the Requirements for Graduation with Distinction with the Degree

More information

Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete

Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete NSERC Industrial Research Chair in Innovative FRP Composites for Infrastructures Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete Prepared by: Ehab A. Ahmed, Ehab El-Salakawy, and Brahim Benmokrane

More information

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Engineering Data for Copper and Aluminum Conductor Electrical Cables 2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION

More information

Current cast-in-place construction process has been used

Current cast-in-place construction process has been used 22 nd International Symposium on Automation and Robotics in Construction ISARC 2005 - September 11-14, 2005, Ferrara (Italy) 1 An Innovative Construction Process-Contour Crafting (CC) Dooil Hwang and Behrokh

More information

Shake Table Analysis of Concrete Structural Models. Keywords: Earthquake, Fiber Reinforced Polymer, shake table, tape confinement, wire mesh.

Shake Table Analysis of Concrete Structural Models. Keywords: Earthquake, Fiber Reinforced Polymer, shake table, tape confinement, wire mesh. Paper ID: SE-009 International Conference on Recent Innovation in Civil Engineering for Sustainable Development () Department of Civil Engineering DUET - Gazipur, Bangladesh 510 Shake Table Analysis of

More information

SM-220-MP SHOCK TEST MACHINE. Halfsine. Sawtooth. Squarewave

SM-220-MP SHOCK TEST MACHINE. Halfsine. Sawtooth. Squarewave SHOCK TEST MACHINE SM-220-MP Halfsine Sawtooth Squarewave Technical subject to changes without prior notice! GUTENBERGSTRASSE 27 D-246 REINBEK / HAMBURG GERMANY SM-220-MP SHOCK TEST MACHINE Dimensions

More information

Current Standard Plates including Transmittal Letters are available on the web at:

Current Standard Plates including Transmittal Letters are available on the web at: MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (6-03) MANUAL: Standard

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

A. Product Data shall be provided for each type of product indicated.

A. Product Data shall be provided for each type of product indicated. 32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical

More information

DOUBLE PUNCH TEST AND TENSILE STRENGTH OF CONCRETE. B. E. Trumbauer. W. F. Chen ABSTRACT. The tensile strength of concrete can be determined by

DOUBLE PUNCH TEST AND TENSILE STRENGTH OF CONCRETE. B. E. Trumbauer. W. F. Chen ABSTRACT. The tensile strength of concrete can be determined by DOUBLE PUNCH TEST AND TENSLE STRENGTH OF CONCRETE by B. E. Trumbauer W. F. Chen ABSTRACT The tensile strength of concrete can be determined by several methods. The most popular method is the indirect split-cylinder

More information

GLASS FIBER-REINFORCED PLASTIC POLES FOR TRANSMISSION AND DISTRIBUTION LINES: AN EXPERIMENTAL INVESTIGATION

GLASS FIBER-REINFORCED PLASTIC POLES FOR TRANSMISSION AND DISTRIBUTION LINES: AN EXPERIMENTAL INVESTIGATION GLASS FIBER-REINFORCED PLASTIC POLES FOR TRANSMISSION AND DISTRIBUTION LINES: AN EXPERIMENTAL INVESTIGATION D. Polyzois, S. Ibrahim, V. Burachynsky, and S. K. Hassan Department of Civil and Geological

More information

THE STUDY OF t-z AND q-z CURVES ON BORED PILE BASED ON THE RESULTS OF INSTRUMENTED PILE LOAD TEST IN MEDIUM AND STIFF CLAYS

THE STUDY OF t-z AND q-z CURVES ON BORED PILE BASED ON THE RESULTS OF INSTRUMENTED PILE LOAD TEST IN MEDIUM AND STIFF CLAYS Proceedings of Pile 2013, June 2-4 th 2013 THE STUDY OF t-z AND q-z CURVES ON BORED PILE BASED ON THE RESULTS OF INSTRUMENTED PILE LOAD TEST IN MEDIUM AND STIFF CLAYS Aswin Lim 1, Aksan Kwanda 2 and Paulus

More information

FINAL REPORT: CONNECTION STRENGTH TESTING TENSAR GEOGRIDS WITHIN MESA STANDARD BLOCKS AND MESA STANDARD CONNECTORS

FINAL REPORT: CONNECTION STRENGTH TESTING TENSAR GEOGRIDS WITHIN MESA STANDARD BLOCKS AND MESA STANDARD CONNECTORS Prepared for: Tensar International Corporation, Limited LLC, Inc. 5883 Glenridge Drive, Suite 2 Atlanta, GA 3328 FINAL REPORT: CONNECTION STRENGTH TESTING TENSAR GEOGRIDS WITHIN MESA STANDARD BLOCKS AND

More information

Portable Rock-Analog Deformation Apparatus (PRADA)

Portable Rock-Analog Deformation Apparatus (PRADA) Portable Rock-Analog Deformation Apparatus (PRADA) Philip Skemer Washington University in St Louis, Department of Earth and Planetary Sciences espm.wustl.edu/prada last updated June 2017 1 Figure 1: Schematic

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the

More information

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2

More information

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES SEISMIC TEST OF CONCRETE BLOCK INFILLE REINFORCE CONCRETE FRAMES Yoshiaki NAKANO 1, Ho CHOI 2, Yasushi SANAA 3 and Naruhito YAMAUCHI 4 1 Associate Professor, Institute of Industrial Science, The University

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights 1 Exam Prep Placing Reinforcing Bars Tabs and s These 1 Exam Prep Tabs are based on the CRSI Placing Reinforcing Bars Recommended Practices, 9 th Edition. Each 1 Exam Prep tabs sheet has five rows of tabs.

More information

An Experimental Investigation on Mechanical Behavior of Macro Synthetic Fiber Reinforced Concrete

An Experimental Investigation on Mechanical Behavior of Macro Synthetic Fiber Reinforced Concrete International Journal of Civil & Environmental Engineering IJCEE-IJENS Vol: 11 No: 03 18 An Experimental Investigation on Mechanical Behavior of Macro Reinforced Concrete M. J. Hasan 1*, M. Afroz 2 and

More information

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS Weichen XUE Professor Tongji University Siping Road 1239#, Shanghai 200092, China xuewc@tongji.edu.cn*

More information

CHECK OF PIEZOELECTRIC TRANSDUCERS USING THE ELECTRO- MECHANICAL IMPEDANCE

CHECK OF PIEZOELECTRIC TRANSDUCERS USING THE ELECTRO- MECHANICAL IMPEDANCE 7th European Workshop on Structural Health Monitoring July 8-, 24. La Cité, Nantes, France More Info at Open Access Database www.ndt.net/?id=759 CHECK OF PIEZOELECTRIC TRANSDUCERS USING THE ELECTRO- MECHANICAL

More information

TYPICAL INSTALLATION INSTRUCTIONS

TYPICAL INSTALLATION INSTRUCTIONS TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect

More information

OPTIMIZED 3/4" GRADATION LIGHTWEIGHT AGGREGATE REPORT

OPTIMIZED 3/4 GRADATION LIGHTWEIGHT AGGREGATE REPORT OPTIMIZED 3/4" GRADATION LIGHTWEIGHT AGGREGATE REPORT PREPARED BY: JODY WALL, P.E. DIRECTOR OF RESEARCH AND DEVELOPMENT CAROLINA STALITE COMPANY RESEARCH LAB GOLD HILL, NORTH CAROLINA Optimized 3/4" Gradation

More information

MANUFACTURING TECHNOLOGY

MANUFACTURING TECHNOLOGY MANUFACTURING TECHNOLOGY UNIT II Hot & Cold Working - Drawing & Extrusion Drawing Drawing is an operation in which the cross-section of solid rod, wire or tubing is reduced or changed in shape by pulling

More information

EFFECT OF REPLACEMENT OF CEMENT BY SILICA FUME ON THE STRENGTH PROPERTIES OF SIFCON PRODUCED FROM WASTE COILED STEEL FIBRES

EFFECT OF REPLACEMENT OF CEMENT BY SILICA FUME ON THE STRENGTH PROPERTIES OF SIFCON PRODUCED FROM WASTE COILED STEEL FIBRES EFFECT OF REPLACEMENT OF CEMENT BY SILICA FUME ON THE STRENGTH PROPERTIES OF SIFCON PRODUCED FROM WASTE COILED STEEL FIBRES Dr. Ashish. K. Gurav Director, Dhananjay Mahadik Group of Institutions,Kolhapur,

More information

SELF-CONSOLIDATING CONCRETE FOR SLIP-FORM CONSTRUCTION: PROPERTIES AND TEST METHODS

SELF-CONSOLIDATING CONCRETE FOR SLIP-FORM CONSTRUCTION: PROPERTIES AND TEST METHODS SELF-CONSOLIDATING CONCRETE FOR SLIP-FORM CONSTRUCTION: PROPERTIES AND TEST METHODS Kejin Wang (1), Surendra P. Shah (2) and Thomas Voigt (3) (1) Department of Civil, Construction and Environmental Engineering,

More information

A H M 531 The Civil Engineering Center

A H M 531 The Civil Engineering Center Workability Tests By: Ahmed Essam Mansour Objectives: The determination of workability of fresh concrete using three approximating methods: 1. The slump test. 2. The compaction factor test. 3. VEBE test.

More information

Wireless Maturity System Applications: Lowe Precast Waco, TX.

Wireless Maturity System Applications: Lowe Precast Waco, TX. Wireless Maturity System Applications: Lowe Precast Waco, TX. 1 Precast Concrete Plant Prior to implementing the Maturity System: Mix designs were created to drive strength in the small 4x8 test cylinders,

More information

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC. PART 1: GENERAL 1.01 Section Includes: 1. Vertical reciprocating conveyor, Hydraulic straddle VRC. a. Machine, controller, platform, structural steel hoist frame. b. Wire mesh enclosure and gates. Related

More information

CYCLIC TESTING OF BOLTED CONTINUOUS I-BEAM-TO-HOLLOW SECTION COLUMN CONNECTIONS

CYCLIC TESTING OF BOLTED CONTINUOUS I-BEAM-TO-HOLLOW SECTION COLUMN CONNECTIONS 10NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 21-25, 2014 Anchorage, Alaska CYCLIC TESTING OF BOLTED CONTINUOUS I-BEAM-TO-HOLLOW SECTION COLUMN

More information

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular

More information

Load carrying capacity of shear wall t-connections reinforced with high strength wire ropes

Load carrying capacity of shear wall t-connections reinforced with high strength wire ropes Downloaded from orbit.dtu.dk on: Feb 19, 2018 Load carrying capacity of shear wall t-connections reinforced with high strength wire ropes Jørgensen, Henrik B.; Bryndom, Thor; Larsen, Michael; Hoang, Linh

More information

MODELING OF LASER BASED DIRECT METAL DEPOSITION PROCESS

MODELING OF LASER BASED DIRECT METAL DEPOSITION PROCESS MODELING OF LASER BASED DIRECT METAL DEPOSITION PROCESS Jayanth N PG Student PSG College of Technology jayanthnagaraj@gmail.com Ravi K R Associate Professor PSG College of Technology Krravi.psgias@gmail.com

More information

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit Genda Chen, Ph.D., P.E. Associate Professor of Civil Engineering Department of Civil,

More information

ANCHOR BOLTS IN CLAY MASONRY WALLS

ANCHOR BOLTS IN CLAY MASONRY WALLS ANCHOR BOLTS IN CLAY MASONRY WALLS Russell H. Brown 1, J. Gregg Borchelt 2 and R. Eric Burgess 3 ABSTRACT This research project was designed to determine the tensile and shear strengths of anchor bolts

More information

***************************************************************************************************************

*************************************************************************************************************** 03365 POST-TENSIONED CONCRETE *************************************************************************************************************** SPECIFIER: CSI MasterFormat 2004 number 03 38 00. ***************************************************************************************************************

More information

2014 East TN Regional Model Bridge Building Contest

2014 East TN Regional Model Bridge Building Contest 1 2014 East TN Regional Model Bridge Building Contest Objective: Location: To build a model bridge, according to prescribed size and weight specifications, that is capable of supporting the greatest load

More information

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN-LINK FENCES AND GATES 02821/1 SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where

More information

FREEZING AND THAWING TESTS OF COMPACTED SOIL-CEMENT MIXTURE

FREEZING AND THAWING TESTS OF COMPACTED SOIL-CEMENT MIXTURE Test Procedure for FREEZING AND THAWING TESTS OF COMPACTED SOIL-CEMENT TxDOT Designation: Tex-135-E Effective Date: August 1999 1. SCOPE 1.1 This method determines the soil-cement losses, moisture changes,

More information

Experimental Investigation on Cold-Formed Steel Foamed Concrete Composite Wall under Compression

Experimental Investigation on Cold-Formed Steel Foamed Concrete Composite Wall under Compression Experimental Investigation on Cold-Formed Steel Foamed Concrete Composite Wall under Compression Zhifeng u, Zhongfan Chen 1 Abstract A series of tests on cold-formed steel foamed concrete (CSFC) composite

More information

Fabrication and characterization of piezoelectric ceramic fiber/aluminum alloy composites

Fabrication and characterization of piezoelectric ceramic fiber/aluminum alloy composites Advances in Materials 214; 3(4): 22-26 Published online September 3, 214 (http://www.sciencepublishinggroup.com/j/am) doi: 1.11648/j.am.21434.11 ISSN: 2327-253 (Print); ISSN: 2327-252X (Online) Fabrication

More information

A Proper Design of Wind Turbine Grounding Systems under Lightning

A Proper Design of Wind Turbine Grounding Systems under Lightning A Proper Design of Wind Turbine Grounding Systems under Lightning M. A. Abd-Allah, Mahmoud N. Ali, A. Said Abstract Lightning protection systems (LPS) for wind power generation is becoming an important

More information

Remote-Controlled Dismantling of the Thermal Isolation and Preparations for the Primary Shield Removal

Remote-Controlled Dismantling of the Thermal Isolation and Preparations for the Primary Shield Removal Remote-Controlled Dismantling of the Thermal Isolation and Preparations for the Primary Shield Removal A. Graf, J. Fleisch, S. Neff, WAK GmbH, Eggenstein-Leopoldshafen, Germany S. Klute, E. Koselowski,

More information

SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE

SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE BE IT ORDAINED by the Town Council of the Town of Plainville: SECTION 1. SUBDIVISIONS. All subdivisions hereinafter developed within

More information

STRENGTH AND BEHAVIOUR OF GEOPOLYMER CONCRETE BEAMS

STRENGTH AND BEHAVIOUR OF GEOPOLYMER CONCRETE BEAMS ISSN (Online) : 2319-8753 ISSN (Print) : 2347-6710 International Journal of Innovative Research in Science, Engineering and Technology An ISO 3297: 2007 Certified Organization, Volume 2, Special Issue

More information

Smart materials. Piezoelectric materials Shape memory materials Magnetostriction materials Electrostriction materials. w.wang 107

Smart materials. Piezoelectric materials Shape memory materials Magnetostriction materials Electrostriction materials. w.wang 107 Smart materials Piezoelectric materials Shape memory materials Magnetostriction materials Electrostriction materials w.wang 107 Qualitative comparison of different smart technology Active System Driving

More information

SECTION STRUCTURAL PRECAST HOLLOW CORE SLABS

SECTION STRUCTURAL PRECAST HOLLOW CORE SLABS PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish all labor, materials, equipment and incidentals to provide a complete structural precast hollow core slab system as shown on the Contract

More information

Standard Practice for Molding Roller-Compacted Concrete in Cylinder Molds Using a Vibrating Hammer 1

Standard Practice for Molding Roller-Compacted Concrete in Cylinder Molds Using a Vibrating Hammer 1 Designation: C 145/C 145M 05 Standard Practice for Molding Roller-Compacted Concrete in Cylinder Molds Using a Vibrating Hammer 1 This standard is issued under the fixed designation C 145/C 145M; the number

More information

Modal Behaviors of Spun-Cast Pre-Stressed Concrete Pole Structures

Modal Behaviors of Spun-Cast Pre-Stressed Concrete Pole Structures Modal Behaviors of Spun-Cast Pre-Stressed Concrete Pole Structures Shen-en Chen 1, Choo Keong Ong 2 and Kris Antonsson 2 1 Department of Civil Engineering, University of North Carolina at Charlotte 9201

More information

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA I.1 June 2005 STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA SUMMARY Glass fiber reinforced polymer (GFRP) grids reinforced polyurea was used to strengthen unreinforced concrete

More information

THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR PERMEABILITY OF HIGH PERFORMANCE CONCRETE

THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR PERMEABILITY OF HIGH PERFORMANCE CONCRETE 2009/2 PAGES 1 7 RECEIVED 10. 1. 2009 ACCEPTED 9. 4. 2009 P. PAULÍK, I. HUDOBA THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR PERMEABILITY OF HIGH PERFORMANCE CONCRETE ABSTRACT Peter Paulík

More information

In-plane testing of precast concrete wall panels with grouted sleeve

In-plane testing of precast concrete wall panels with grouted sleeve In-plane testing of precast concrete wall panels with grouted sleeve P. Seifi, R.S. Henry & J.M. Ingham Department of Civil Engineering, University of Auckland, Auckland. 2017 NZSEE Conference ABSTRACT:

More information

THE DESIGN AND FABRICATION OF AN AUTOMATED SHEAR STUD WELDING SYSTEM. Andrew Glenn Ziegler, Research Assistant

THE DESIGN AND FABRICATION OF AN AUTOMATED SHEAR STUD WELDING SYSTEM. Andrew Glenn Ziegler, Research Assistant THE DESIGN AND FABRICATION OF AN AUTOMATED SHEAR STUD WELDING SYSTEM Andrew Glenn Ziegler, Research Assistant Alexander Henry Slocum, Assistant Professor of Civil Engineering Massachusetts Institute of

More information

E APPENDIX. The following problems are intended for solution using finite element. Problems for Computer Solution E.1 CHAPTER 3

E APPENDIX. The following problems are intended for solution using finite element. Problems for Computer Solution E.1 CHAPTER 3 E APPENDIX Problems for Computer Solution The following problems are intended for solution using finite element analysis software. In general, the problems associated with Chapters 3, 4, and 9 can be solved

More information

Image Analysis of Kevlar 49 Fabric at High Strain Rate

Image Analysis of Kevlar 49 Fabric at High Strain Rate Proceedings of the XIth International Congress and Exposition June -5, 8 Orlando, Florida USA 8 Society for Experimental Mechanics Inc. Image Analysis of Kevlar 49 Fabric at High Strain Rate Deju Zhu (),

More information

PRISM TEST, FLAT JACK TEST, REBOUND HAMMER, & MECHANICAL PULSE VELOCITY

PRISM TEST, FLAT JACK TEST, REBOUND HAMMER, & MECHANICAL PULSE VELOCITY PRISM TEST, FLAT JACK TEST, REBOUND HAMMER, & MECHANICAL PULSE VELOCITY PRISM TEST(Introduction) It is a laboratory test to calculate the compressive strength of a masonry prism. The prism can be obtained

More information

Influence of CDW Recycled Aggregate on Drying Shrinkage of Mortar

Influence of CDW Recycled Aggregate on Drying Shrinkage of Mortar Open Journal of Civil Engineering, 2012, 2, 53-57 http://dx.doi.org/10.4236/ojce.2012.22009 Published Online June 2012 (http://www.scirp.org/journal/ojce) Influence of CDW Recycled Aggregate on Drying

More information

Foundation Manual. Part Number: Version: Updated: July 5, S. Meadows Pkwy. A-9, #329 Reno, NV

Foundation Manual. Part Number: Version: Updated: July 5, S. Meadows Pkwy. A-9, #329 Reno, NV Foundation Manual Part Number: 150002 Version: 1.22 Updated: July 5, 2009 748 S. Meadows Pkwy. A-9, #329 Reno, NV 89521 775-831-9463 www.mariahpower.com July 2009, Mariah Power, All Rights Reserved Dear

More information

STUDY ON MECHANICAL PROPERTIES OF LIGHT TRANSMITTING CONCRETE

STUDY ON MECHANICAL PROPERTIES OF LIGHT TRANSMITTING CONCRETE International Research Journal of Engineering and Technology (IRJET) e-issn: 239-6 STUDY ON MECHANICAL PROPERTIES OF LIGHT TRANSMITTING CONCRETE B.YAMINI NIRMAL 1, Mr. K.NEHEMIYA 2, Sri.G.GIRI PRASAD 3,

More information

RECOMMENDATIONS FOR THE CONNECTION BETWEEN FULL-DEPTH PRECAST BRIDGE DECK PANEL SYSTEMS AND PRECAST I-BEAMS

RECOMMENDATIONS FOR THE CONNECTION BETWEEN FULL-DEPTH PRECAST BRIDGE DECK PANEL SYSTEMS AND PRECAST I-BEAMS FINAL CONTRACT REPORT VTRC 07-CR17 RECOMMENDATIONS FOR THE CONNECTION BETWEEN FULL-DEPTH PRECAST BRIDGE DECK PANEL SYSTEMS AND PRECAST I-BEAMS DON P. SCHOLZ Graduate Research Engineer JOSEPH A. WALLENFELSZ

More information

Valmont Newmark is your single source for steel, concrete or hybrid structures for power delivery

Valmont Newmark is your single source for steel, concrete or hybrid structures for power delivery Valmont Newmark is your single source for steel, concrete or hybrid structures for power delivery Valmont Newmark is your single source for steel, A Tradition of Meeting Needs. Building on its steel pole

More information

Utilization of Air Permeability In Predicting The Thermal Conductivity

Utilization of Air Permeability In Predicting The Thermal Conductivity ORIGINAL PAPER/PEER-REVIEWED Utilization of Air Permeability In Predicting The Thermal Conductivity By Pamela Banks-Lee a *, Massoud Mohammadi b, Parviz Ghadimi c Abstract: General linear regression models

More information

Pile to Slab Bridge Connections

Pile to Slab Bridge Connections Pile to Slab Bridge Connections Mohamed I. Ayoub 1, David H. Sanders 2 and Ahmed Ibrahim 3 Abstract Slab bridges are a common bridge type, where the pile extends directly from the ground to the superstructure.

More information

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College SECTION 323113 - CHAIN LINK FENCES AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PERFORMANCE OF LAP SPLICES IN CONCRETE MASONRY SHEAR WALLS UNDER IN-PLANE LOADING

PERFORMANCE OF LAP SPLICES IN CONCRETE MASONRY SHEAR WALLS UNDER IN-PLANE LOADING PERFORMANCE OF LAP SPLICES IN CONCRETE MASONRY SHEAR WALLS UNDER IN-PLANE LOADING J. Z. MJELDE 1, D.I. MCLEAN 2, J. J. THOMPSON 3 AND W. M. MCGINLEY 4 1 Graduate Student, 2 Professor and Chair Department

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

AIR QUENCHING OF ALUMINUM: THE AFFECT OF QUENCH ORIENTATION AND AIR VELOCITY

AIR QUENCHING OF ALUMINUM: THE AFFECT OF QUENCH ORIENTATION AND AIR VELOCITY AIR QUENCHING OF ALUMINUM: THE AFFECT OF QUENCH ORIENTATION AND AIR VELOCITY A Major Qualifying Project Report Submitted to the Faculty of WORCESTER POLYTECHNIC INSTITUTE In partial fulfillment of the

More information

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES PART 1: SCOPE CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES 1.1 An Approved Celcore Applicator shall furnish all labor, materials and supervision

More information

Influence of Restraint Conditions and Reinforcing Bar on Plastic Shrinkage of Self-consolidating Concrete

Influence of Restraint Conditions and Reinforcing Bar on Plastic Shrinkage of Self-consolidating Concrete Influence of Restraint Conditions and Reinforcing Bar on Plastic Shrinkage of Self-consolidating Concrete Parviz Ghoddousi 1, and Ali Akbar Shirzadi Javid 2 1 Assistant Professor of Civil Engineering at

More information

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories. SECTION 02830 CHAIN LINK FENCES AND GATES (GALVANIZED) 1.0 GENERAL 1.1 Section Includes A. Fence framework, fabric, gates, and accessories. B. Excavation for post bases; concrete footing for posts. C.

More information

Advanced Technology for Large Structural Systems Research Center Lehigh University Bethlehem, PA

Advanced Technology for Large Structural Systems Research Center Lehigh University Bethlehem, PA Advanced Technology for Large Structural Systems Research Center Lehigh University Bethlehem, PA MATERIAL TESTING ANALYSIS FOR THE SELF-CENTERING CONCENTRICALLY BRACED FRAME Prepared by: Javier Miranda

More information

Moisture analyzers (moisture meters) FIZEPR-SW100

Moisture analyzers (moisture meters) FIZEPR-SW100 www.fizepr.ru Design Bureau FIZELEKTRONPRIBOR Moisture analyzers (moisture meters) FIZEPR-SW100 for liquid, paste-like and bulk materials including petroleum, fuel oil, sand, coal, ore, concrete mixture,

More information

FIRE DURABILITY OF VOLCANIC PUMICE CONCRETE WITH SPECIAL REFERENCE TO THIN WALLED FILLED SECTIONS Durability of volcanic pumice concrete

FIRE DURABILITY OF VOLCANIC PUMICE CONCRETE WITH SPECIAL REFERENCE TO THIN WALLED FILLED SECTIONS Durability of volcanic pumice concrete FIRE DURABILITY OF VOLCANIC PUMICE CONCRETE WITH SPECIAL REFERENCE TO THIN WALLED FILLED SECTIONS Durability of volcanic pumice concrete K. M. A. HOSSAIN The Papua New Guinea University of Technology,

More information

SECTION CAST-IN-PLACE CONCRETE

SECTION CAST-IN-PLACE CONCRETE SECTION 03300 CAST-IN-PLACE CONCRETE PART 1 GENERAL 1.01 SECTION INCLUDES A. The Contractor shall furnish all work and materials, including cement, sand and coarse aggregate, water, admixtures, curing

More information

Keywords: Drying Shrinkage of Concrete, Autogenous Shrinkage, Design Shrinkage Strain

Keywords: Drying Shrinkage of Concrete, Autogenous Shrinkage, Design Shrinkage Strain A Discussion on the Shrinkage Interpretation from the Experimental Shrinkage Measurement Based on the Australian Testing Procedure AS1012.13 William A. Thomas¹, James Mohammadi² and Dr Warren South³ ¹Chief

More information

SELF-SEALING CEMENT-BASED MATERIALS USING SUPERABSORBENT POLYMERS

SELF-SEALING CEMENT-BASED MATERIALS USING SUPERABSORBENT POLYMERS SELF-SEALING CEMENT-BASED MATERIALS USING SUPERABSORBENT POLYMERS Hai Xiang Dennis Lee (1), Hong Seong Wong (1) and Nick Buenfeld (1) (1) Concrete Durability Group, Imperial College London, UK Abstract

More information

Specified Tests for Concrete Quality

Specified Tests for Concrete Quality Specified Tests for Concrete Quality Behnam Neyestani Introduction Concrete is unique among construction materials in that it requires various degrees of processing between arriving on site and being placed,

More information

Morgan State University CE STRUCTURES AREA LABORATORIES

Morgan State University CE STRUCTURES AREA LABORATORIES CE STRUCTURES AREA LABORATORIES The facilities in the structures area include the following: 1) 2) 3) CE Materials Laboratory (CBEIS 124), CE Structures Laboratory (CBEIS 125), and CE Structures Research

More information

THE INTELLIGENT CHOICE. Autoclaved Aerated Concrete Production Plants

THE INTELLIGENT CHOICE. Autoclaved Aerated Concrete Production Plants THE INTELLIGENT CHOICE Autoclaved Aerated Concrete Production Plants Autoclaved aerated concrete plants PLANTS High quality, economic and flexible. Characterised by outstanding precision, productivity

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS ITEM 00663 TRAFFIC BUTTONS & PAVEMENT MARKERS 663.1 Description. This item shall consist of furnishing and installing traffic buttons and reflectorized pavement markers and jiggle

More information

Study on Estimated In-situ Cube Strength from Cores and Cube Strength

Study on Estimated In-situ Cube Strength from Cores and Cube Strength Study on Estimated In-situ Cube Strength from Cores and Cube Strength Undergraduate Research Opportunities Program (UROP) Report submitted by SEAH JIN WERN JAIME 99-6004W-11 Supervisor: A. Prof. Swaddiwudhipong

More information

Attachment A-Flagpole(s) Specifications

Attachment A-Flagpole(s) Specifications Attachment A-Flagpole(s) Specifications PART 1-GENERAL 1.1 SCOPE A. The scope of work includes the removal of existing flagpole(s) and associated concrete bases, and installation of a new flagpole(s) and

More information

INTERNSHIP REPORT GOUTHAM.J

INTERNSHIP REPORT GOUTHAM.J INTERNSHIP REPORT GOUTHAM.J M.E Structural Engineering SNS College of Technology, Coimbatore Mail : tcegoutham@gmail.com TEEMAGE PRECAST IN College Road, 1st Cross Street, Tirupur 641602. TamilNadu, India.

More information

EXTERNAL CONFINEMENT OF PLAIN AND REINFORCED CONCRETE COLUMNS USING PVC PIPES

EXTERNAL CONFINEMENT OF PLAIN AND REINFORCED CONCRETE COLUMNS USING PVC PIPES 19 th - 2 th November 216, in Dubai, U.A.E ISBN: 9788193137376 EXTERNAL CONFINEMENT OF PLAIN AND REINFORCED CONCRETE COLUMNS USING PVC PIPES Dr.R.Kumutha Department of Civil Engineering, Sethu Institute

More information

Testing of Concrete Blocks

Testing of Concrete Blocks Testing of Concrete Blocks By Er. Kaushal Kishore, Materials Engineer, Roorkee INTRODUCTION Concrete can be converted into precast masonry units such as Hollow and Solid normal and light weight concrete

More information

Modelling shearing characteristics of reinforced concrete

Modelling shearing characteristics of reinforced concrete University of Wollongong Research Online Faculty of Engineering - Papers (Archive) Faculty of Engineering and Information Sciences 2005 Modelling shearing characteristics of reinforced concrete Hossein

More information

4.1 DETERMINATION OF SPECIFIC GRAVITY

4.1 DETERMINATION OF SPECIFIC GRAVITY TESTS ON CEMENT 94 4.1 DETERMINATION OF SPECIFIC GRAVITY STANDARD IS: 4031-1988. DEFINITION Specific Gravity is defined as the ratio of the mass of the cement to the mass of an equal volume of kerosene.

More information

SEISMIC QUALIFICATION TESTING OF CONCRETE EXPANSION ANCHORS TO NUCLEAR STANDARDS

SEISMIC QUALIFICATION TESTING OF CONCRETE EXPANSION ANCHORS TO NUCLEAR STANDARDS SEISMIC QUALIFICATION TESTING OF CONCRETE EXPANSION ANCHORS TO NUCLEAR STANDARDS T. S. Aziz 1), A. Ghobarah 2) 1) Atomic Energy of Canada Ltd, 2251 Speakman Drive, Mississauga, Ontario, Canada L5K 1B2

More information

(FRP) ( CFRP

(FRP) ( CFRP ISSN: 23195967 Effect of Temperature on Strength of Concrete Strengthening With CFRP H. Shehab El Din, Heba A. Mohamed hshehabeldin@yahoo.com, hebawahbe@yahoo.com Dean & Professor of Reinforced Concrete,

More information