1 CUSTOM SKYLIGHTS ATTRACTIVE, EFFICIENT WINDOWS FOR YOUR ROOF SINGLE DOME DOUBLE DOMECIRCULAR DOME CONTINUOUS PRE-FORMED CURBS

2 Skylights GENERAL INFORMATION Single Dome For natural light transmission. Available square or rectangular, or with pyramid dome. Skylight Function LEXCOR Skylights are a model of efficiency. These windows on the roof are designed to shut out inclement weather, are shaped to wash themselves in rain, can be insulated (double domes), will provide ventilation, access to the roof and even help fight fires. Sometimes a skylight is the only way to bring natural daylight into a building. On a square foot basis, skylights admit far more light and distribute light much more evenly than a vertical window simply because they face directly towards the sky. Skylights may also be used to advantage in building entrances to enhance foyers or spotlight attractive features such as sculptures, murals, paintings, planters, reflecting pools, etc. A whole room roofed over with skylighting can add greatly to the atmosphere of a garden court or restaurant. The use of cheerful, attractive daylighting with dome skylights is leading to new design concepts in residential construction. The natural appeal of bringing the outdoor scene indoors provides a unique sales attraction for home builders. And residents of many existing homes have found that skylights can turn a dark bathroom into a bright one without loss of privacy, make a garage corner or laundry into a cheerfully efficient workspace or inexpensively open up an attic for add-a-room modeling. Skylight Construction Supplied to the building site in pre-assembled form where possible, LEXCOR skylights are constructed of two components - a shatterproof molded acrylic skylight dome and an exclusively designed aluminum curb frame. Domes are offered in a variety of shapes. Curb frames may be mounted to wood or concrete curbs constructed by others, or to preformed metal curbs supplied by LEXCOR. Use For all commercial, industrial, institutional or residential buildings. With flat or sloping roofs, any construction. For new construction or renovation of existing structures. For conventional or unusual applications. Skylight General Features Wide range of standard types, dome colour and sizes to suit virtually any function or aesthetic requirement; also custom fabricated to any size or shape for unusual lighting effects. Free daylighting provides ELEC- TRIC POWER SAVINGS and subsequent maintenance of artificial lighting. Fast installation of pre-assembled units minimizes on-site costs. Positive curb frame seal stops wind, rain, snow and dust; pliability of seal permits free expansion of acrylic during atmospheric change; low conductivity of acrylic resists formation 2 Double Dome For natural light transmission and improved thermal resistance. Available square or rectangular, or with pyramid dome. of condensation. Optional curb frame available. Engineered to meet National Building Code live load requirements. Adds to apparent size of small rooms. Acrylic dome materials proven to resist discoloration, hazing and loss of strength in more than a half-century of successful outdoor use. Meets fire code requirements when tested in accordance with ASTM D Manufactured and designed in Canada Dome Configurations Domes are available in the standard bubble shape as illustrated above for single Dome and Double Dome Skylights, or alternately is a pyramid shape as shown below. For other dome configurations, consult with your LEXCOR representative. Approvals + Compliances CAN/CGSB M89 CAN/ULC S-102.2

3 Domes Rigid Vinyl Air-Lock Framing Retaining Screws Circular Dome For natural light transmission. Available with optional ceilinglite and/or well liner. Continuous For increased natural light transmission, ideal for long, linear applications. For 102mm Curb Curb, Caulking and Flashing by Others Acrylic Dome colour Domes are offered in a choice of acrylic colour briefly described below: Clear Acrylic (Colorless) Allows maximum light penetration and permits view of sky. Glare from the sun and privacy should be considered when choosing a clear dome. White Acrylic (Translucent) For optimum diffused light and control of solar heat. Most popular for day lighting applications. Tinted Grey and Bronze Transparent colour reduce interior solar heat gain and control glare while permitting clear vision to outdoors. Grey tints provide much natural colour retention. Bronze tints may make outdoors slightly brighter while actually reducing light intensity. Sufficient light is transmitted through tinted domes to support most plant life; lighter densities for plants requiring maximum sunlight, darker densities for plants requiring partial shade. Thickness of acrylic may be 3 mm, 5 mm or 6 mm depending on skylight size. Special colour A wide range of transparent and translucent colour are available for special effect. Double Domes vs Single Domes Although all skylights may be supplied with single domes, double domes are recommended; they provide greater insulation than single domes i.e. will reduce heat build-up in summer and heat loss in winter. Double domes also guard against condensation and reduce sound transmission. The following table shows average U values for acrylic skylights. Values are per.093 m2 (1 sq. foot) of well opening (not dome surface). Metric U value is expressed as W/(m 2 C) and Imperial U value is expressed as Btu/(ft 2 h F). Winter Summer DOME TYPE Heat Loss Heat Gain Metric Imperial Metric Imperial Double Dome Single Dome Standard Features Domes 6mm Neoprene With Drain Gaps 6mm Dia. Weep Holes 3 Extruded Alum. Retaining and Curb Selection LEXCOR curb frames are fabricated using 6063-T5 extruded aluminum alloy and are available in two frame styles - Standard and. The Standard frame features an outward sloping angle with condensation gutter and weep holes, to channel off condensation. For sloped roofs, weep holes occur on bottom side of frame only. The frame, of slightly different configuration, is supplied with a hollow vinyl thermal barrier. The thermal barrier virtually eliminates the formation of frost around the interior of the curb frame, which if under certain conditions were allowed to accumulate and thaw, might drip into the light well. Aluminum curb frames are mill finished as standard. An optional Duracron (Thermosetting acrylic) 100 architectural metal finish or anodized aluminum finish is available in a wide range of colour at extra cost. Related References For additional technical data regarding acrylic dome materials, special structural design requirements, light and heat transmittance values and other properties, contact LEXCOR. Availability LEXCOR skylight products are distributed across Canada Warranty Normal 5 year guarantee against faulty materials and workmanship. Maintenance Acrylic domes are self-washing and require no maintenance; the smooth dome finish and shape discourages dirt. However, if fine cleaning is desired, domes may be cleansed using most household detergents or ammonia and water. Do not use paint thinners, turpentine and similar solvents for cleaning.

4 Types LEXCOR curb frames are fabricated using 6063-T5 extruded aluminum alloy and are available in two frame styles - Standard and. NO-FROST FRAME The frame is supplied with a hollow vinyl thermal barrier. The thermal barrier virtually eliminates the formation of condensation around the interior of the curb frame, which if under certain conditions were allowed to accumulate, might drip into the light well. The Standard frame, of slightly different configuration does not have a thermal barrier and is somewhat less expensive than the frame. This frame type is recommended for buildings with a very low humidity level. Both frame types however feature an outward sloping angle with condensation gutter and weep holes, to channel off condensation. Aluminum frames are mill finished as standard. An optional Duracron (Thermosetting acrylic) 100 architectural metal finish is available in a wide range of colour at extra cost.. Sizes Data* FOR 41 mm (1 5/8 ) CURB STANDARD FRAME MODEL # B x B (mm + Ins.) D (mm + Ins.) NFFDD x 362 (14-1/4 x 14-1/4) 127 (5) NFFDD x 565 (14-1/4 x 22-1/4) 127 (5) NFFDD x 1175 (14-1/4 x 46-1/4) 178 (7) NFFDD x 483 (19 x 19) 133 (5-1/4) NFFDD x 565 (22-1/4 x 22-1/4) 178 (7) NFFDD x 768 (22-1/4 x 30-1/4) 178 (7) NFFDD x 1175 (22-1/4 x 46-1/4) 178 (7) NFFDD x 768 (22-1/4 x 30-1/4) 178 (7) NFFDD x 1175 (22-1/4 x 46-1/4) 178 (7) NFFDD x 2273 (25-1/2 x 89-1/2) 216 (8-1/2) NFFDD x 768 (30-1/4 x 30-1/4) 203 (8) NFFDD x 940 (30-1/4 x 37) 254 (10) NFFDD x 1175 (30-1/4 x 46-1/4) 254 (10) NFFDD x 1397 (30-1/4 x 55) 254 (10) NFFDD x 1765 (30-1/4 x 69-1/2) 254 (10) NFFDD x 940 (37 x 37) 254 (10) NFFDD x 1905 (37 x 75) 330 (13) NFFDD x 1499 (38 x 59) 305 (12) NFFDD x 1175 (46-1/4 x 46-1/4) 305 (12) NFFDD x 1765 (46-1/4 x 69-1/2) 305 (12) NFFDD x 2273 (46-1/4 x 89-1/2) 305 (12) NFFDD x 1397 (55 x 55) 357 (14) NFFDD x 1765 (57-1/2 x 69-1/2) 394 (15-1/2) NFFDD x 2273 (57-1/2 x 89-1/2) 406 (16) NFFDD x 1702 (67 x 67) 406 (16) NFFDD x 1905 (75 x 75) 457 (18) NFFDD x 2349 (92-1/2 x 92-1/2) 559 (22) *Single dome skylights are available in the same sizes as double domes. Substitute prefix D for DD in model number. If standard frame is desired in lieu of, delete NFF portion of prefix on model number. Double Dome Skylights SQUARE AND RECTANGLE For natural light transmission and improved thermal conductivity. Available in square or rectangle dome shapes. NOTE: These units can be used with LEXCOR factory manufactured curbs. See curb page. For single domes, see note below. B x B + 159mm (6-1/4 ) To 41mm (1-5/8 Curb Opening) 41mm (1-5/8 ) Wood Curb B x B 100mm (4 ) Concrete Curb Double Dome pre-assembled plastic skylights supplied by LEXCOR, of size and type as per Model No. for [41 mm (1 5/8 )][100 mm (4 )] wide curb; complete with clear acrylic outer dome, [clear][white translucent] inner dome and [] [Standard] 6063-T5 extruded aluminum alloy, mill finished curb frame and retaining frame. FOR 100 mm (4 ) CURB (suffix C indicates 100 mm (4 ) wide curb) MODEL # B x B (mm + Ins.) D (mm + Ins.) NFFDD2828C 445 x 445 (17-1/2 x 17-1/2) 178 (7) NFFDD2836C 445 x 648 (17-1/2 x 25-1/2) 178 (7) NFFDD2852C 445 x 1054 (17-1/2 X 41-1/2) 178 (7) NFFDD2896C 527 X 2153 (20-3/4 X 84-3/4) 216 (8-1/2) NFFDD3636C 648 X 648 (25-1/2 X 25-1/2) 203 (8) NFFDD3642C 648 X 819 (25-1/2 X 32-1/4) 254 (10) NFFDD3652C 648 X 1054 (25-1/2 X 41-1/2) 254 (10) NFFDD3660C 648 X 1276 (25-1/2 X 50-1/4) 254 (10) NFFDD3676C 648 X 1645 (25-1/2 X 64-3/4 254 (10) NFFDD4242C 819 x 819 (32-1/4 x 32-1/4) 254 (10) NFFDD4280C 819 x 1784 (32-1/4 x 70-1/4) 330 (13) NFFDD4364C 845 x 1378 (33-1/4 x 54-1/4) 305 (12) NFFDD5252C 1054 x 1054 (41-1/2 x 41-1/2) 305 (12) NFFDD5276C 1054 x 1645 (41-1/2 x 64-3/4 305 (12) NFFDD5296C 1054 x 2153 (41-1/2 x 84-3/4 305 (12) NFFDD6060C 1276 x 1276 (50-1/4 x 50-1/4) 357 (14) NFFDD6476C 1340 x 1645 (52-3/4 x 64-3/4 394 (15-1/2) NFFDD6496C 1340 x 2153 (52-3/4 x 84-3/4) 406 (16) NFFDD7272C 1581 x 1581 (62-1/4 x 62-1/4) 406 (16) NFFDD x 1784 (70-1/4 x 70-1/4) 457 (18) NFFDD x 2229 (87-3/4 x 87-3/4) 559 (22) 4

5 Insulated Curb Skylights Sloped Roof Skylights Skylight supplied complete with integral, insulted aluminum curb for quick and convenient installation. For Natural light transmission over residential sloped or pitched roofs. 3mm x 13mm (1/8 x 1/2 ) Neoprene Gasket with Drain Caps B x B + 159mm (6-1/4 ) B x B (159mm (6-1/4 ) D Extruded Vinyl Draft Seal 6mm (1/4 ) Dia. Weep Holes Staggered Caulking Rigid Vinyl Thermal Barrier 0.61mm (.025 ) Inner Aluminum Liner 2.4mm (0.93 ) Aluminum Curb & Curb B x B 51mm (2 ) Rigid Insulation 229mm (9 ) 6mm (1/4 ) Weep holes Bottom side only (Staggered) Rigid Insulation 51mm x 44mm (2 x 1-3/4 ) Rigid insulation Roofing, Caulking, and interior finish by others Roofing, Flashing, Caulking and interior finish by others Set curb frame in bed of roof mastic before fastening down 76mm (3 ) At Top and sides. set roof flange under shingles LEXCOR insulated curb, double dome pre-assembled plastic skylights supplied by LEXCOR of size and type as per Model No. ; complete with clear acrylic outer dome, [clear][white translucent inner dome], 220 mm (9 ) high 6063-T5 extruded aluminum alloy, mill finish curb frame, and 50 mm (2 ) wide aluminum curb filled with rigid insulation. Sloped Roof pre-assembled plastic skylights supplied by LEXCOR, of size and type as per Model No., complete with clear outer dome [clear] [white translucent] inner dome and insulated 6063-T5 mill finished extruded aluminum alloy selfflashing frame. Sizes Data (a) The two size charts are applicable to both Sloped Roof and insulated Curb Skylights, (b) For sloped roof curb prefix SR; (c) For 9 high insulated type curb prefix A; (d) For single dome prefix D. MODEL # B x B (mm + Ins.) D (mm + Ins.) DD x 362 (14-1/4 x 14-1/4) 127 (5) DD x 565 (14-1/4 x 22-1/4) 127 (5) DD x 1175 (14-1/4 x 46-1/4 178 (7) DD x 483 (19 x 19) 133 (5-1/4) DD x 565 (22-1/4 x 22-1/4) 178 (7) DD x 768 (22-1/4 x 30-1/4 178 (7) DD x 1175 (22-1/4 x 46-1/4) 178 (7) DD x 2273 (25-1/2 x 89-1/2) 216 (8-1/2) DD x 768 (30-1/4 x 30-1/4) 203 (8) DD x 940 (30-1/4 x 37) 254 (10) DD x 1175 (30-1/4 x 46-1/4) 254 (10) DD x 1397 (30-1/4 x 55) 254 (10) DD x 1765 (30-1/4 x 69-1/2) 254 (10) MODEL # B x B (mm + Ins.) D (mm + Ins.) DD x 940 (37 x 37) 254 (10) DD x 1905 (37 x 75) 330 (13) DD x 1499 (38 x 59) 305 (12) DD x 1175 (46-1/4 x 46-1/4) 305 (12) DD x 1765 (46-1/4 x 69-1/2) 305 (12) DD x 2273 (46-1/4 x 89-1/2 305 (12) DD x 1397 (55 x 55) 357 (14) DD x 1765 (57-1/2 x 69-1/2) 394 (15-1/2) DD x 2273 (57-1/2 x 89-1/2) 406 (16) DD x 1702 (67 x 67) 406 (16) DD x 1905 (75 x 75) 457 (18) DD x 2349 (92-1/2 x 92-1/2) 559 (22) 5

6 B mm (6-1/4 ) Continuous Skylights (THERMALLY FORMED DOMES) B mm (6-1/4 ) To Suit Mould Sizes Intermediate Aluminum Dome Supports to Suit D D Neoprene Spacers and Vynil Gaskets 102mm (4 ) 41mm (1-5/6 ) Wood Curb Curb, Roofing, Flashing, and caulking by others Curb Height 203mm (8 ) Min. B1 100mm (4 ) Concrete Curb Curb, Roofing, Flashing, and caulking by others Curb Height 203mm (8 ) Min. B2 PART LONGITUDINAL SECTION As Desired Thermally formed continuous plastic skylights supplied by LEXCOR, of size and type as per Model no. for [41 mm (1 5/8 )][100 mm (4 )] wide curb; complete with [clear outer dome][clear][white translucent][inner dome] and 6063-T5 mill finished extruded aluminum alloy [] [Standard] frame, and cross-band dome supports with resilient gaskets, spaced [approximately 1219 mm (4'0 ) on centre]. Overall length of unit as shown on drawings. Sizes MODEL NO. B1 MODEL NO. B2 D 41 mm (1-5/8 ) CURB (mm + Ins.) 100 mm (4 ) CURB (mm + Ins.) (mm + Ins.) NFFCONDD (24) NFFCONDD24C 489 (19-1/4) 152 (6) NFFCONDD (30) NFFCONDD30C 641 (25-1/4) 178 (7) NFFCONDD (36) NFFCONDD36C 794 (31-1/4) 203 (8) NFFCNDD (42) NFFCONDD42C 946 (37-1/4) 229 (9) NFFCONDD (48) NFFCONDD48C 1099 (43-1/4) 254 (10) NFFCONDD (54) NFFCONDD54C 1251 (49-1/4) 279 (11) NFFCONDD (60) NFFCONDD60C 1403 (55-1/4) 305 (12) NFFCONDD (72) NFFCONDD72C 1708 (67-1/4) 356 (14) NFFCONDD (84 NFFCONDD84C 2013 (79-1/4) 406 (16) * If single dome is required, delete NFF and DD portion of prefix on Model No.'s. Single dome units are applied with standard aluminum frame unless otherwise requested. Continuous Skylights (COLD FORMED DOMES) 133mm (5-1/4 ) Centre to centre of pre-arced alum. Double acrylic skylight Caulking & Ethafoam Rope Backing Aluminum Curb and Retaining 6mm (1/4 ) Dia. Weep Holes 610mm (24 ) O.C. Any Width up to 3353mm (11-0 ) Aluminum Mounting Bracket Rigid Vynil Thermal Barrier NOTE: Curb, Roofing, Flashing, and Caulking by others. Curb Height 203mm (8 )Min. Continuous neoprene spacer blocks Caulking and Ethafoam rope backing Caulking by installer length as desired Continuous Welds 114mm (4-1/2 ) Wide Mullions NOTE: For single acryilic skylight detail, delete lower skylight panel and spacer blocks PART LONGITUDINAL SECTION Cold formed continuous plastic skylights supplied by LEXCOR; of size and type as shown on the drawings for 100 mm (4 ) wide curb; complete with [clear][white translucent][single acrylic dome][clear outer dome][clear][white translucent][inner dome] and 6063-T5 mill finished extruded aluminum alloy frame, and prearced aluminum mullions with resilient gaskets, spaced [approximately 1219 mm (4'0 ) on centre, and vertical end panels. Sizes Data Continuous skylights (cold formed domes) are manufactured on a custom basis. Any length may be specified and any width up to 3.35 m (11'0 ) for outside curb dimension may be specified. 6

7 Prefab Insulated Curbs 41mm (1-5/8 ) Or as Req d Circular Dome Skylights 50mm (2 ) 300mm (12 ) or as req d 25mm (1 ) Rigid Insulation Prepunched 12mm (1/2 ) Dia. 89mm (3-1/2 ) For natural light transmission and round skylight effect. Standard Curb Profile Materials - 16 GA. GALV. STEEL (other gauges available) Galv. Steel - 11 ga., 14 ga., 16 ga., 18 ga. Aluminum -.064,.081. Optional Burglar Bars: _ dia. Steel In 4 grid pattern welded in curb where additional security is req'd. Curbs can be ordered with wood nailers or changes in dimensions other than shown on standard curb profile. IDEAL FOR SKYLIGHTS WHEN CURB HEIGHT OVER 9 REQ'D For deck openings up to 2480 mm x 2980 mm (96 x 144 ), curbs can be supplied pre-assembled with welded corners. Joiner plates are supplied for larger sizes. Typical Installation of LEXCOR CURB Aluminum Retaining Angle 51mm (2 ) Alum. Curb filled with fibreglass insulation Roofing by others B + 159mm (6-1/4 ) B Dia. 229mm (9 ) Curb Flashing Flange 76mm (3 ) Curb HTS See Note Deck Bolted to Deck Metal Screws Curb Roof Flange (1) Position curb frame over roof opening provided and secure to deck. Check plans allowing location of bolt holes in curb frame and roof flange Counter Flashing Fibre Cant & B.U.R. Roof Insulation (2) Install roof insulation (by others, if required) and cant strip (by others). Each Lexcor unit is complete with 1 glass fibre board insulation secured to outside of curb frame. (3) Carry all flashing felts up cant strip and undercurb frame flashing lange. Install counter flashing and secure to curb frame with metal screws. Circular Dome pre-assembled plastic skylights supplied by LEXCOR, of size and type as per Model No. ; complete with clear outer dome, [clear][white translucent] inner dome and 50 mm (2 ) wide x 220 mm (9 ) high insulated 6063-T5 mill finished aluminum curb. Sizes Data* Model B DIA (mm + ins.) D (mm + ins.) CADD (24) 203 (8) CADD (31) 279 (11) CADD (43) 330 (13) CADD (54) 483 (19 CADD (67) 559 (22) CADD (79) 635 (25) CADD (91) 737 (29 * If single dome is required, delete DD portion of prefix on Model No.s 7

8 ROOF HATCHES Series 100 Through 120 All Lexcor Hatches are the ultimate in economy and rugged performance. Designed to provide permanent, trouble free performance for safe access to roof. Installation is a quick simple operation. Place hatch over roof opening and fasten hatch flange to deck. THREE STANDARD SIZES FOR EASY ROOF ACCESS Series 100 Ladder Access Sizes 2'6 x 3'0' I.D. (762mm x 914mm) Series 110 Steep Stair Sizes 2'6 x 4'6 I.D. (762mm x 1372mm) Series 120 Normal Stair Sizes 2'6 x 8'0 I.D. (762mm x 2438mm) AVAILABLE WITH ACRYLIC DOMED LIDS AND EXCLUSIVE VANDAL PROOF INTEGRAL METAL GRID SERIES For equipment Installation, Servicing and Removal CUSTOM SIZES SINGLE LEAF For opening up to 5'-0 (1524mm) Wide Series 130 CUSTOM SIZES DOUBLE LEAF For almost any clear opening size For further information on Hatches, Smoke and Explosion Vents see Lexcor s Hatch Brochure.

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

RS32 Multi-Section Skylight System under/over seam clip double diverter

RS32 Multi-Section Skylight System under/over seam clip double diverter INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series

More information

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents Roof Accessories Distributed by: BEST MATERIALS Ph: 800-474-7570, 602-272-8128 www.bestmaterials.com Email: Sales@BestMaterials.com Division 07 72 33 Roof Hatches Roof Safety Rails Safety Posts Division

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

RS24-10 Single-Section Skylight System

RS24-10 Single-Section Skylight System INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980

More information

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage:

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage: Item Description Smoke Vent Product Information Description: Smoke Vents (Acrylic) provide a double glazed, 100% Impact Modified 0.181" outer lens and a 50% Impact Modified 0.120" inside lens that is hail

More information

Custom fabrication in two weeks or less, guaranteed.

Custom fabrication in two weeks or less, guaranteed. Custom fabrication in two weeks or less, guaranteed. Ask us how Ramco can now fabricate hardware on all manufacturers blank doors in 2 weeks or less. ramcometals.com got lead times? Ramco offers custom

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 07/13/2014 Issued: 07/13/2012 Visit www.ati-es.com for current status Revised: 08/22/2012 Page 1 of

More information

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131 ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 Subject to Renewal: 10/27/09 Issued: 10/27/08 Visit for current status Revised 11/5/08 Page 1 of 10 Solatube International, Inc 2210 Oak

More information

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects 3.0 Statement Columbia Skylights Statement for New Construction (NC) Version 3.0 Credit Documentation The Leadership in Energy and Environmental Design () Green Building Rating System promotes the adoption

More information

Custom Daylighting Structures

Custom Daylighting Structures METAL FRAMED SKYLIGHTS Product 086300 CANOPIES 107316 TRANSLUCENT WALLS 084500 wascoskylights.com ENLIGHTENED LIVING Custom Daylighting Structures WASCOSKYLIGHTS.COM We ll See Your Vision Through Wasco

More information

(866) 7-DAYSTAR. toll-free. DayStar Systems, LLC Hwy 4 Campbell Hill, IL 62916

(866) 7-DAYSTAR. toll-free. DayStar Systems, LLC Hwy 4 Campbell Hill, IL 62916 DayStar Systems, LLC. 14226 Hwy 4 Campbell Hill, IL 62916 tel (618) 426-1868 fax (618) 426-1888 toll-free (866) 7-DAYSTAR DayStar Daylighting Systems are manufactured in Campbell Hill, Illinois and sold

More information

Domes Pyramids Opening Rooflights Flatglass Rooflights

Domes Pyramids Opening Rooflights Flatglass Rooflights Domes Pyramids Opening Rooflights Flatglass Rooflights The Roofglaze range of modular rooflights offers a huge variety of solutions for introducing natural light into all kinds of buildings, with options

More information

7520 Casement Windows

7520 Casement Windows Full casement Single casement Double-bottom casement Double casement FULL DOUBLE CASEMENT - Min 1 9 1 6 Max 3 0 5 0 or 2 6 6 0 CASEMENT W/ PICTURE - Min 4 6 1 6 Max 12 0 6 0 with 30 vent set - Minimum

More information

SunWave Prismatic Skylights

SunWave Prismatic Skylights Item Description Fixed Skylights Product Information SunWave Prismatic Skylight Options: Class 1 Units offers Acrylic outer lens options in a single*, double, and triple* glazed configuration. 100% Impact

More information

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs. PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs. 1.2 PERFORMANCE REQUIREMENTS A. Structural

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

ACOUSTICAL ACOUSTICAL. Page

ACOUSTICAL ACOUSTICAL. Page lesser scaups - also known as Bluebills These are the most common Scaup... The other Greater Scaup much less common and only slightly different. For all intends and purposes these are the "Bluebills" hunters

More information

Uniclass G321:G24 L414 CI/SfB (37.41) December Flat Roofing and Waterproofing Systems. Alumasc. Daylighting Systems

Uniclass G321:G24 L414 CI/SfB (37.41) December Flat Roofing and Waterproofing Systems. Alumasc. Daylighting Systems Flat Roofing and Waterproofing Systems Uniclass G:G L CI/SfB (7.) December 00 Alumasc Introduction Contents Introduction Alumasc A Range Superior Modular Rooflights Alumasc B Range Standard Modular Rooflights

More information

A clear vision of what you imagined

A clear vision of what you imagined A clear vision of what you imagined PUR DESIGN 100AD-200AD-300AD Commercial panoramic door JPR s PUR DESIGN Series doors are manufactured to meet the highest standards of performance and aesthetics. Designed

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

SECTION TURBINE VENTILATORS

SECTION TURBINE VENTILATORS SECTION 07 72 00 TURBINE VENTILATORS **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular project.

More information

Spandrel Glass Types and Recommendations

Spandrel Glass Types and Recommendations Introduction Vitro (formerly PPG Industries) has long offered recommendations regarding alternatives for glass spandrel applications. Over the years these recommendations were included in various publications

More information

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors Architectural Manual Thermally Improved Aluminum Series Windows & Patio Doors Instructions on how to use this manual: This document has been designed for easy navigation and to quickly click to the section

More information

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500 07721 ROOF ASSEMBLY SUPPORTS FOR ROOFTOP EQUIPMENT ****************************************** SPECIFIER: All roof-related items above or outside the structural roof deck, including such work as blocking,

More information

FLOOR AND AREA DRAINS

FLOOR AND AREA DRAINS Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA

More information

SWING DOOR SPECIFICATION

SWING DOOR SPECIFICATION SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified

More information

Awning Windows Montecito New Construction Window

Awning Windows Montecito New Construction Window Awning Windows Montecito New Construction Window Full awning Double-top awning Double awning Double-bottom awning FULL DOUBLE BOTTOM/TOP DOUBLE AWNING - Min 1 3 1 4 Max 4 6 3 0 AWNING - Min 3 0 1 6 Max

More information

Casement Windows Montecito New Construction Window

Casement Windows Montecito New Construction Window Casement Windows Montecito New Construction Window Full casement Double-bottom casement FULL DOUBLE/SINGLE DOUBLE CASEMENT - Min 1 6 1 0 Max 3 0 5 0 or 2 6 6 0 CASEMENT - Min 3 0 1 6 Max 6 0 5 0 or 5 0

More information

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION 07530CP EPDM MEMBRANE ROOFING PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL

More information

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows. SECTION 085113 - ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes fixed and operable aluminum-framed windows. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide aluminum windows capable

More information

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8 SLIDING WINDOW PAGE 1 PAGE 1 SPECIFICATIONS GENERAL Sliding windows shall be Marlin series #3500-HC (thermally improved) as manufactured by Marlin windows, and shall conform to ANSI/AAMA 101-88 HS-HC40. Series #3500 shall have

More information

Sculpted 3D Minimal. Rain Screen Wall System

Sculpted 3D Minimal. Rain Screen Wall System Sculpted 3D Minimal Rain Screen Wall System Metalwërks Sculpted frees designers to create iconic facades more easily and affordably than ever before by elevating three-dimensional wall panels to entirely

More information

Tremline. Fascia System. Installation Procedures

Tremline. Fascia System. Installation Procedures Tremline Fascia System Installation Procedures 5 TOP CAP MITERED TOP CAPS JOINT PLATE RIGHT-HAND END CAP PREFAB OUTSIDE CORNER 10 FASCIA FASCIA HOLDER 10 FASCIA CLAMPING RING DECK BRACKET SCUPPER PREFAB

More information

Vinyl Windows and Doors

Vinyl Windows and Doors Install Atrium 0UZ[PSS *VUÄKLUJL Vinyl Windows and Doors Atrium Vinyl Windows A Commitment to Excellence Since 1948 Welcome the beauty of The Vinyl Advantage Vinyl is the ideal material for engineering

More information

SECTION HVAC GRAVITY VENTILATORS

SECTION HVAC GRAVITY VENTILATORS SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

TUNNELS III.

TUNNELS III. F FOLDER TUNNELS 2009 2015 III www.fakro.pl SUN FAKRO light tunnels are designed to bring natural light to every part of a property. The light tunnel makes it possible to illuminate all rooms in the building,

More information

PREFA Aluminiumprodukte GmbH Page 1 of 21

PREFA Aluminiumprodukte GmbH Page 1 of 21 Tender Specifications 120901 PREFA Shingles_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------

More information

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing 6 Drainable Louver Section Page Number Catalogue Page 2 Page 7 Performance Data Page LP-12 Page LP-13 Submittals Drawing 237947 Update to Louvers Catalog C-1.0 April 2010 Louvers General Product Overview

More information

Vinyl Replacement Windows and Doors

Vinyl Replacement Windows and Doors Install Atrium Instill Confidence Vinyl Replacement Windows and Doors A Commitment to Excellence Since 1948 Welcome the beauty of nature into your home with precision-crafted windows and doors from Atrium.

More information

Vertigo Cladding Board

Vertigo Cladding Board Installation guide Vertigo Cladding Board Geolam: a stunning alternative to wood cladding Vertigo is a composite wood cladding board requiring minimum maintenance. Durable and fade resistant, it will not

More information

SECTION G RELIEF VENTS A-0

SECTION G RELIEF VENTS A-0 SECTION G A-0 TABLE OF CONTENTS Thaler Or Equal RV-1A/-RV-1C Relief Vent RV-2A/-RV-2C Relief Vent RV-3A/-RV-3C One Way Relief Vent Relief Vent Specification G-0 G-1 G-2 G-3 G-4, G-5, G-6 WHAT IT TAKES

More information

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK A. 1. Using curb ribs as a guide, layout and mark roof openings on completed roof deck as outside curb

More information

PVC-U: Innovations and product ranges

PVC-U: Innovations and product ranges PVC-U: Innovations and product ranges Be successful with Schüco 4 pillars of success 1 2 3 4 Product innovations Ranges Sales support Marketing Productivity gains Machinery and application technology Speed

More information

HomeMaker3 Windows and Doors

HomeMaker3 Windows and Doors HomeMaker3 Windows and Doors A Better Experience We re so much more than windows OUR MISSION: GETTING IT RIGHT EVERY TIME As one of the nation s largest suppliers of high-quality windows for existing and

More information

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents.

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents. Roof Accessories Division 07 72 33 Roof Hatches Roof Safety Rails Safety Posts Division 07 72 36 Smoke Vents www.activar.com Construction Products Group ROOF HATCH: Galvanized Steel or Aluminum RHG & RHA

More information

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes Application and Design Florida Product Approved Drainable Blade Louver is a Florida Product Approved stationary drainable blade extruded aluminum louver designed to protect air intake and exhaust openings

More information

INSTALLATION GUIDE.

INSTALLATION GUIDE. INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten

More information

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this

More information

Product information Roof terrace GEL + VEA/VEB/VEC

Product information Roof terrace GEL + VEA/VEB/VEC Edition 1.0 01.07.2015 Product information Roof terrace GEL + VEA/VEB/VEC Product description High quality natural pinewood coated with impregnation and layers of water-based acrylic clear lacquer or white

More information

LOUVER PRODUCTS. Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline Louvers

LOUVER PRODUCTS. Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline Louvers LOUVER PRODUCTS Archives of Ontario Building, York University, Toronto, Ontario Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline

More information

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017] [Change these specifications as needed. Use this sample proposal at your own risk. This is a simple, general proposal and is not meant to be a comprehensive proposal for all situations or projects. If

More information

BALCONY & FAÇADE DESIGN

BALCONY & FAÇADE DESIGN BALCONY & FAÇADE DESIGN Page 4-5 Sustainable and resource-friendly renovation Solarlux offers future-proof concepts. New build or renovation added value for house and residents Page 6-9 Use and enjoy open

More information

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors TIE Aluminum Guide Spec: Thermally Improved Windows & Doors Thermally Improved Aluminum Windows (TIE) ALUMINUM WINDOWS - 08 51 13 With the thin lines that Milgard s TIE Aluminum Windows provide, they

More information

Division 08 OPENINGS TABLE OF CONTENTS

Division 08 OPENINGS TABLE OF CONTENTS Division 08 OPENINGS TABLE OF CONTENTS 08 1000 GENERAL... 2 A. RELATED DIVISIONS... 2 B. GENERAL... 2 08 1000 DOORS AND FRAMES... 2... 2 B. EXTERIOR DOORS AND FRAMES... 2 C. DOOR FRAMES... 2 D. HOLLOW

More information

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 10530 PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

10 EXTREME BASEMENT PANELS

10 EXTREME BASEMENT PANELS 10 EXTREME BASEMENT PANELS On Granular Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions. Soils are classified

More information

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division

More information

Commercial skylights 2007 edition

Commercial skylights 2007 edition Commercial skylights 2007 edition Table of contents 03 VELUX 04 Skylights affect the environment 06 Flat roof patterned toplighting 11 Flat roof patterned toplighting with suspended ceiling 12 VELUX structural

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated

More information

ALLMET CONTINENTAL INSTALLATION GUIDE

ALLMET CONTINENTAL INSTALLATION GUIDE ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental

More information

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits. 1 GENERAL 1.1 SECTION INCLUDES 1.1.1.1 Aluminum Siding. 1.1.1.2 Aluminum Soffits. 1.1.1.3 Thermally Broken Façade Sub-structure. 1.1.1.4 Aluminum trim and accessories. 1.2 RELATED SECTIONS 1.2.1 Section

More information

Series 510-I Thermal Heavy Commercial Projected Window

Series 510-I Thermal Heavy Commercial Projected Window Windows Curtain Walls Entrances Storefronts Series 510-I Thermal 2-7 16 Heavy Commercial Projected Window Configurations Project-In Project-Out Casement Fixed Series 510-I retains an AAMA Architectural

More information

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION IMPACT RESISTANT WALL PROTECTION SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,

More information

Product information Roof balcony CABRIO GDL

Product information Roof balcony CABRIO GDL Edition 2.0 01.04.2016 Product information Roof balcony CABRIO GDL Product description High quality natural pinewood coated with impregnation and layers of water-based acrylic white paint or clear lacquer

More information

4 EXTREME FOUNDATION PANELS

4 EXTREME FOUNDATION PANELS 4 EXTREME FOUNDATION PANELS For House Crawl Space On Concrete Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions.

More information

Quality. Care. Commitment. series 8000 doors supreme quality

Quality. Care. Commitment. series 8000 doors supreme quality Series 8000 Thermally Broken Aluminum Sliding Door Body copy Subhead Body c Product Specifications Extrusion Details Test Reports Quality. Care. Commitment. series 8000 doors supreme quality 777 Aldridge

More information

Skylights, Canopies, Walkways, Wall Systems & Interiors. Translucent Polycarbonate MULTI-WALL PANEL SYSTEMS

Skylights, Canopies, Walkways, Wall Systems & Interiors. Translucent Polycarbonate MULTI-WALL PANEL SYSTEMS Skylights, Canopies, Walkways, Wall Systems & Interiors Translucent Polycarbonate MULTI-WALL PANEL SYSTEMS BDL Polycarbonate PANEL systems CO-EX'S BDL is a system of standing seam modular panels used to

More information

LUX Specifications. Section S - Preformed Steel Siding

LUX Specifications. Section S - Preformed Steel Siding Part 1 General.1 System-1: Installation over building paper or air barrier membrane, on exterior grade gypsum board or exterior grade wood sheathing. 1.2 RELATED SECTIONS.1 Section 01 11 00 Summary of

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

Picture/Radius Windows Montecito New Construction Window

Picture/Radius Windows Montecito New Construction Window Picture/Radius Windows Montecito New Construction Window Picture window Half-round Round?top/picture Picture?window gable Picture?window octagon Quarter?Round Round?top PICTURE WINDOW - Min 1 6 1 6 Max

More information

Pre-Fabricated Roof Curbs

Pre-Fabricated Roof Curbs Knock Down Curb Assembly Instructions These roof curb assembly instructions are to be used as general guidelines only. Included with shipment are as-built drawings for proper location of sections and channels.

More information

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON ADDENDUM NUMBER FROM: MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 0 / 533 WEST MAIN STREET TUPELO, MS 3880 / 3880 FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON PHONE: -8-00 PROJECT: ACADEMIC STUDENT

More information

The Cascade Story. Looking for a window company that offers superior customer service and the right products at the right price?

The Cascade Story. Looking for a window company that offers superior customer service and the right products at the right price? cascadewindows.com The Cascade Story Looking for a window company that offers superior customer service and the right products at the right price? Cascade Vinyl Colors Optional Paint Colors Welcome to

More information

3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows

3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows 3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows 3000 SERIES FIBERGLASS - Min 1 6 2 9 Max 4 0 7 0 - Min 3 0 2 9 Max 8 0 7 0 Double-Hung Double Double-Hung - Min 4 6 2 9 Max 12 0 7 0 Minimum

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Series x Thermal Triple Set Storefront Framing

Series x Thermal Triple Set Storefront Framing Series 433 2 x 4 1 2 Thermal Triple Set Storefront Framing CONFIGURATIONS Screw Spline Shear Block System 433 is a thermally broken storefront framing system. Glass planes can be placed in an outside set,

More information

60 years. of progressive development

60 years. of progressive development Dencroft has been providing a wide range of sectional buildings for over 60 years, making us one of the most experienced designers and manufacturers of quality garages in the UK. Innovation has played

More information

CITY OF CITRUS HEIGHTS BUILDING & SAFETY DIVISION

CITY OF CITRUS HEIGHTS BUILDING & SAFETY DIVISION BUILDING & SAFETY DIVISION 6360 FOUNTAIN SQUARE DRIVE, CITRUS HEIGHTS, CA 95621 Phone: (916) 727-4760 Purpose: To establish a procedure for complying with the provisions of Chapter 15 of the California

More information

Product information Additional window element GIU

Product information Additional window element GIU Edition 1.0 15.12.2014 Product information Additional window element Product description High quality moulded polyurethane with white lacquer finish Fixed window element (non opening) For installation

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION The selection of a wall type and appropriate connection details is one of the most important

More information

UV- and Abrasion-Resistant Vertical Glazing. UV- Resistant Sloped and Overhead Glazing. Bullet-Resistant and Forced-Entry Security Glazing

UV- and Abrasion-Resistant Vertical Glazing. UV- Resistant Sloped and Overhead Glazing. Bullet-Resistant and Forced-Entry Security Glazing GE Structured Products LEXAN MR10 Sheet UV- and Abrasion-Resistant Vertical Glazing LEXAN XL10 Sheet LEXAN LEXGARD Laminates LEXAN 9034 Sheet LEXAN THERMOCLEAR Sheet UV- Resistant Sloped and Overhead Glazing

More information

SMART ATTIC LADDERS.

SMART ATTIC LADDERS. SMART ATTIC LADDERS 2015 1 MODELS & APPLICATIONS OF FAKRO ATTIC LADDERS GENERAL INFORMATION TO CONFORMANCE 14.9 2004 FOR AT TIC L A D D E R S MANUFACTURER CERTIFIES TO CONFORMANCE 14.9 2004 FOR AT TIC

More information

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES 2016-03-24 Page 1 SECTION 08360 SECTIONAL OVERHEAD DOORS DESCRIPTION MODEL 900 PRODUCT FEATURES Sectional steel overhead doors, industrial grade heavy duty construction. BASIC USES / RELATED USES Sectional

More information

Commercial Dynamic Dome Unit Skylight - Guide Specification

Commercial Dynamic Dome Unit Skylight - Guide Specification Commercial Dynamic Dome Unit Skylight - Guide Specification For over 70 years, VELUX has been delivering energy efficient daylight to living spaces where people, live, work, and play. VELUX is the world

More information

optimize daylighting Opportunities

optimize daylighting Opportunities optimize daylighting Opportunities DESIGN STRATEGIES DESIGN STRATEGIES NATURAL LIGHTING FOR ENERGY EFFICIENCY DAYLIGHTING Using indirect natural light to illuminate indoor spaces as an alternative to electric

More information

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home Designed and built by New Mexico landscape architect John Mosely for his own Santa Fe home. The solar greenhouse shown

More information

Sub-construction for Wall-mounted Longlight

Sub-construction for Wall-mounted Longlight modular skylights Sub-construction for Wall-mounted Longlight Subconstruction for Wall-mounted Longlight at 5-40 pitch modular skylights in a wall-mounted longlight solution, can be installed on a sub-construction

More information

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance

More information

Selecting Cover Systems

Selecting Cover Systems Selecting Cover Systems Construction Specialties offers a wide variety of expansion joint covers for every joint size, movement requirement and finish material you may encounter. Selecting the proper cover

More information

The Alternative to Storefront. Gerkin Model 58F

The Alternative to Storefront. Gerkin Model 58F The Alternative to Storefront Gerkin Model 58F Why do we need an alternative? To provide windows with factory glazing To eliminate water leaks To eliminate the need for sill flashing w/ end dams To reduce

More information

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A440-08

More information

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows Series 2050 Garden Window The Series 2050 standard garden window has an outstanding reputation for its distinctive design and excellent

More information

Lexan* Thermopanel Sheet LTP30B4RS36. Property Profile Value Test Method. Lexan*

Lexan* Thermopanel Sheet LTP30B4RS36. Property Profile Value Test Method. Lexan* Description Lexan* polycarbonate is an unique engineering thermoplastic which combines a high level of mechanical, optical and thermal properties. When extruded in multi-wall sheet form with calibrated

More information

Protan Exposed Membrane Roof. Your design - Our solution

Protan Exposed Membrane Roof. Your design - Our solution Protan Exposed Membrane Roof Your design - Our solution Exposed membrane roof The principle function of a roof is to provide durable protection against the external environment to a building. Unprotected

More information