HOLD DOWN CLIPS #WGACHD LIFT & SHIFT CLIPS #WGACLNS [19.05] 3/4" 1/4" [6.35]TYP. REVEAL HOLD DOWN CLIP (BY OTHERS) FASTENERS LIFT & SHIFT
|
|
- Marsha Jefferson
- 5 years ago
- Views:
Transcription
1 SAFETY CLIPS 5/6" H.D. T-GRID #8x5/8" OR PANHEAD SCREWS SAFETY CLIP 3" = '-0" [6.35] TYP. REVEAL LIFT & SHIFT SYSTEM SECTION [9.05] [6.35]TYP. REVEAL SAFETY CLIP 6" = '-0" HOLD DOWN CLIP LIFT & SHIFT CLIP 3 HOLD DOWN CLIP 6" = '-0" 4 LIFT & SHIFT CLIP 6" = '-0" NOTES: 5/6" H.D. T-GRID ALL CLIPS AND PANEL SCREWS PROVIDED BY ACOUSTIGREEN AND INSTALLED BY OTHERS. PANELS FOR 9/6" T-GRID NOT AVAILABLE. WOOD PANEL LIFT & SHIFT CLIPS 5 LIFT & SHIFT PANEL REMOVAL 3" = '-0" LIFT & SHIFT CEILING PANEL SYSTEM DRAFTED BY: YN/BCO LAST REVISED: 5/3/6 AS NOTED
2 NOTE: HOLES ARE PRE DRILLED FOR LIFT & SHIFT CLIPS AND FOR SAFETY CLIPS. LIFT & SHIFT PANELS ARE LIMITED TO 4" WIDTH. x CLG. PANELS 5/6" H.D. T-GRID SAFETY CLIPS HOLD DOWN CLIPS BACK OF X PANELS /" = '-0" 4" TAP FOR #8x5/8" SCREW (TYP.) 35/64" 4" " BACK OF PANEL 5/6" [33.53] TYP. [9.0] TYP. LIFT & SHIFT X PANEL TAP /" = '-0" LIFT & SHIFT X PANELS DRAFTED BY: YN/BCO LAST REVISED: 5/4/6 AS NOTED
3 NOTE: HOLES ARE PRE DRILLED FOR LIFT & SHIFT CLIPS AND FOR SAFETY CLIPS. LIFT & SHIFT PANELS ARE LIMITED TO 4" WIDTH. x4 CLG. PANELS (6) PER PANEL 5/6" H.D. T-GRID SAFETY CLIPS BACK OF X4 PANELS /" = '-0" 48" 35/64" TAP FOR #8x5/8" SCREW (TYP.) 5/6" [33.53] TYP. 4" BACK OF PANEL LIFT & SHIFT X4 PANEL TAP /" = '-0" [9.0] TYP. LIFT & SHIFT X4 PANELS DRAFTED BY: YN/BCO LAST REVISED: 5/4/6 AS NOTED
4 x6 CLG. PANELS NOTE: HOLES ARE PRE DRILLED FOR LIFT & SHIFT CLIPS AND FOR SAFETY CLIPS. LIFT & SHIFT PANELS ARE LIMITED TO 4" WIDTH. (8) PER PANEL 5/6" H.D. T-GRID SAFETY CLIPS BACK OF X6 PANELS /" = '-0" 7" 4" 35/64" TAP FOR #8x5/8" SCREW (TYP.) BACK OF PANEL 5/6" [33.53] TYP. 35/64" " = '-0" 4" O.C. MAX. LIFT & SHIFT X6 PANEL TAP [9.0] TYP. LIFT & SHIFT X6 PANELS DRAFTED BY: YN/BCO LAST REVISED: 5/4/6 AS NOTED
5 5/6" H.D. T-GRID NOTE: HOLES ARE PRE DRILLED FOR LIFT & SHIFT CLIPS AND FOR SAFETY CLIPS. LIFT & SHIFT PANELS ARE LIMITED TO 4" WIDTH. (8) PER PANEL SAFETY CLIPS x8 CLG. PANELS BACK OF X8 PANELS " = '-0" 96" 4" O.C. TYP. 4" O.C. TYP. 4" TAP FOR #8x5/8" SCREW (TYP.) BACK OF PANEL 5/6" [33.53] TYP. LIFT & SHIFT X8 PANEL TAP = '-0" 35/64" [9.0] TYP. LIFT & SHIFT X8 PANELS DRAFTED BY: YN/BCO LAST REVISED: 5/4/6 AS NOTED
6 NOTES: VERTICAL RETURN FOR HEAVY DUTY APPLICATION ONLY ALL CLIPS AND PANEL SCREWS PROVIDED BY ACOUSTIGREEN AND INSTALLED BY OTHER FIELD CUT MITER CORNER, JOINT GLUED OR PINNED IN FIELD VERTICAL WOOD TRIM SUPPLIED 96" LENGTH TYP. UNLESS SPEC. (MAX 0") Ø DOWEL TO GRID 5/6" H.D. T-BAR VARIES PER SPEC EXPOSED END 3/64" [5.] LIFT & SHIFT CLIP /6" [6.99] CLIP #8x5/8" PAN HEAD SCREWS 7/8" [.3] [9.0] [6.35] ACOUSTIGREEN STANDARD CEILING TILES [6.35] TYP. REVEAL [9.05] LIFT & SHIFT VERTICAL RETURN 6" = '-0" LIFT & SHIFT CEILING PANEL SYSTEM VERTICAL RETURN DRAFTED BY: YN/BCO LAST REVISED: 5/4/6 AS NOTED
7 5/6" H.D. T-GRID SCHEDULED PARTITION " [5.43] [9.05] [6.35] TYP. REVEAL PERIMETER WALL ANGLE PERIMETER OPTIONS PANEL ON WALL ANGLE 6" = '-0" 5/6" H.D. T-GRID SCHEDULED PARTITION PERIMETER WALL ANGLE " [5.43] [9.05] [6.35] TYP. REVEAL [6.35] LIFT & SHIFT CLIP ON WALL ANGLE 6" = '-0" LIFT & SHIFT CEILING PANEL SYSTEM PERIMETER OPTIONS DRAFTED BY: YN/BCO LAST REVISED: 5/4/6 AS NOTED
8 5/6" H.D. T-GRID PANEL IN INSTALLED RESTING POSITION LIFT UP & SHIFT TO THE LEFT TILT/BRING RIGHT SIDE DOWN PANEL THEN SLIDES OUT LIFT & SHIFT INSTALLATION INSTRUCTIONS DRAFTED BY: YN/BCO LAST REVISED: 5/4/6 AS NOTED
9 5/6" H.D. T-GRID '-0" [609.54] O.C. / GRID TO GRID 5/6" H.D. T-GRID '- /6" SAFETY CLIPS PANEL IN INSTALLED RESTING POSITION [585.73] INSIDE DIM. BETWEEN TEE FLANGES '- 7/6" [595.3] OUTSIDE DIM. CLIP TO CLIP #8x5/8" PAN HEAD SCREWS 3/6" [4.75] OVERLAP ON EACH TEE FLANGE LIFT AND SHIFT CEILING SYSTEM NOTE: IF THE GRID AND CLIPS ARE INSTALLED PROPERLY THE ONLY WAYS THE CLIPS WILL COME OFF OF THE TEE FLANGE ARE AS FOLLOWS:. THE STANDARD LIFT AND SHIFT METHOD OF REMOVAL.. THE GRID HAS SHIFTED OR DISLODGED OUT OF SQUARE CAUSING ONE OR MORE OF THE CLIPS TO COME OFF OF THE FLANGE. (THIS CAN BE MINIMIZED BY THE USE OF THE ON PANELS THAT ARE NOT ROUTINELY REMOVED FOR ACCESS. THESE CLIPS ALLOW THE PANELS TO HELP HOLD THE GRID SQUARE, AND ARE FURNISHED WITH THE PANELS.) 3. THE PANEL CONTRACTED MORE THAN 3/6" OF AN INCH. (THERE WILL BE SOME NATURAL EXPANSION/ CONTRACTION OF THE PANELS DUE TO ENVIRONMENTAL CHANGES IN TEMPERATURE AND HUMIDITY. WITHIN THE SPECIFIED RANGE OF 50 DEG. F TO 86 DEG. F, AND 5% TO 55% RELATIVE HUMIDITY THE PANEL WILL CONTRACT NO MORE THAN 3/3 OF AN INCH.) 4. THE PANEL HAS BOWED MORE THAN /4 INCHES. (THIS CAN BE CAUSED BY GRAVITY SAG OR ENVIRONMENTAL CONDITIONS, PRIMARILY HUMIDITY OUTSIDE OF THE SPECIFICATIONS. SEE NO. 3.) 5. A COMBINATION OF CONTRACTION AND BOWING. (WITHIN THE SPECIFIED ENVIRON- MENTAL CONDITIONS THE COMBINATION OF BOW AND SAG WOULD HAVE TO EXCEED 5/8 OF AN INCH BOW, AND THE PANEL CONTRACTED MORE THAN 3/3 OF AN INCH.) 6. REVERSE PROCESS FOR INSTALLATION. LIFT & SHIFT INSTALLATION INSTRUCTIONS DRAFTED BY: YN/BCO LAST REVISED: 5/4/6 AS NOTED
Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector
mm M0-.5 Turnbuckle connections to structural steel 30mm Perimeter Extrusion Simple supported 4 screw assembly and vertically supported flanged grid 750 Montevideo Road Tel (40)799-4200 Main Runner with
More informationMETALWORKS RH215 Faceted Custom Hook-on Panels
METALWORKS RH215 Faceted Custom Hook-on Panels Assembly and Installation Instructions 1. GENERAL 1.1 Product Description MetalWorks RH215 Faceted Custom Hook-on panel system is a downward accessible, custom
More informationSPECIFICATIONS (unless noted otherwise)
2" 150F SYSTEM PROFILE 5 7 8 " NOM. CARRIER SPLICE SEE DETAIL B1.4 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 DETAIL 'A' TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 1 VERTICAL
More informationRockfon Concealed Acoustical Ceiling Systems (CDX and SCD)
Part of the ROCKWOOL Group Rockfon Concealed Acoustical Ceiling Systems (CDX and SCD) Installation Guide Frameless wall system -- Enhanced design freedom using different shapes, angles and wall distances
More informationRockfon Concealed Acoustical Ceiling Systems (CDX and SCD)
Part of the ROCKWOOL Group Rockfon Concealed Acoustical Ceiling Systems (CDX and SCD) Installation Guide Acoustic Ceiling Tile -- Ideal solution for various design applications, including Office, Classroom,
More informationInstall Instruction LOOP RECESSED
LOOP RECESSED T F W 604.549.9379 604.549.9555 fluxwerx.com Install Instruction 1 X 1 6" X 1 6" X 1.5 ATTENTION: This installation guide does not apply to Loop Recessed 1x2, 2x2, 1x4, 2x4, 6"x2 and 6"x4.
More informationBasic Suspension Systems
CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system
More informationInstallation Instructions
STORE AND INSTALL BLANKETS SUCH THAT THE PRODUCT REMAINS DRY. NOTES: 1. Verify that the structural gap and blockout dimensions are in conformance with submittal data before beginning installation. Certification
More informationEDGE D2 CONNECT GRID. Design and technique. Installation manual. Load. Product description. Stability. Plenum height. Weight.
EDGE D2 Design and technique Product description Gyptone edge D2 is a pre-painted, acoustic suspended ceiling mounted in a concealed 24 mm grid system. The ceiling can be used for many applications like
More informationOptima Vector Plank. Installation Instructions. Ceiling
Ceiling Systems Between us, ideas become reality Optima Vector Plank Installation Instructions 1. GENERAL 1.1. Product Description The Vector products referenced in these instructions are made from fiberglass.
More informationCEILING & WALL SYSTEMS
CEILING & WALL SYSTEMS Axiom Perimeter Trim Commercial Ceilings and Walls Solutions Guide Axiom Perimeter Trim AXIOM Trim The Axiom family of products provide functional and visual options in ceiling design.
More informationOPTIMA Vector Plank Installation Instructions
CEILING SYSTEMS Between us, ideas become reality OPTIMA Vector Plank Installation Instructions 1. GENERAL 1.1. Product Description The Vector products referenced in these instructions are made from fiberglass.
More informationMETALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description
Ceiling Systems Between us, ideas become reality METALWorkS General Installation Instructions RH200 Custom Hook-on Panels 1.0 GENERAL 1.1. Product Description RH200 system is a downward accessible, metal
More informationNortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1
16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationSECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)
Tectum Inc. 105 South Sixth Street Newark, OH 43055 Phone: (888) 977-9691 Phone: (740) 345-9691 Fax: (800) 832-8869 E-mail: info@tectum.com www.tectum.com This MANU-SPEC utilizes the Construction Specifications
More informationJASPER. PAGE 2: 2x2 T-GRID INSTALLATION. PAGE 3: 2x2 SRI SHEETROCK INSTALLATION. PAGE 4: 2x2 IEM INSTALLATION
2016 JASPER CM2082 (2x2) PAGE 2: 2x2 T-GRID INSTALLATION PAGE 3: 2x2 SRI SHEETROCK INSTALLATION PAGE 4: 2x2 IEM INSTALLATION PAGE 5: INSTALLATION OF THE EARTHQUAKE CLIPS Drawing: 762300XX_2x2 Rev: A Sheet:
More information2.5" Min. Stud or Runner. 1.5" Mineral Fiber Blanket in Cavity, If Required. Wallboard. Retaining Angle. 1" Min. Damper Sleeve on 10" centers.
General Notes: When UL is referred to in this document, it represents UL/ULC. This installation instruction applies to Fire s (static, dynamic, curtain, single and multi-blade types) mounted in the plane
More informationAXIOM Building Perimeter System Assembly and Installation Instructions
CEILING SYSTEMS AXIOM Building Perimeter System Assembly and Installation Instructions 1 GENERAL 1.1 Description Axiom Building Perimeter Systems (ABPS) is a pre-engineered perimeter solution to accomplish
More informationInstallation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip
Resilmount A237R Furring channel sound isolation clip Installation Instructions Another Quality Building Product Installation A237R SPECIFICATIONS Width: 1-3/8 eight (including rubber): 1-1/16 Length:
More information6" MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP.
5 7 8 " NOM. 2" TYPICAL SYSTEM SECTION VERTICAL SUPPORT SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP. CARRIER SPLICE SEE DETAIL B1.4 6" MAX CARRIER OVERHANG, TYP. 1 12 GA HANGER
More informationInstallation Instructions
STORE AND INSTALL BLANKETS SUCH THAT THE PRODUCT REMAINS DRY. NOTES: 1. Verify that the structural gap and blockout dimensions are in conformance with submittal data before beginning installation. Certification
More informationKAM KNURLED ANGLE MOLDING ANGLE MOLDINGS " LAM-12 LOCKING ANGLE MOLDING DRYWALL CEILING GRID MBAC MAIN BEAM ADAPTER CLIP
HD80 8" TYP HD806 8" TYP KAM-020 KNURLED ANGLE KAM-2020 KNURLED ANGLE KNURLED ANGLE ANGLE S HD806 F08 8" 8" TYP 4 2 " S ATTACHMENT CLIP HD806 F6 8" TYP 3 3 4 (XL84P) PROFILES 8" QSUTC QUIKSTIX UP TIGHT
More informationInstruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)
SOUND ISOLATION CLIPS Installation Manual Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIP SPECIFICATIONS Width...1.00 inch Height...1.06 inch Length...3.86
More informationSuspension System Data Center Ceiling Solutions
Hardware That Needs to be Purchased Separately Screws are fine listed as shown: Min 1-1/4" or longer #8 Truss head self-tapping screws for attaching structural wall angle, lateral support bar 16" or 4"
More informationPRELUDE. 24 MAX TM Suspension System Data Centre Ceiling Solutions. Assembly and Installation Instructions
Hardware That Needs to be Purchased Separately Screws are fine listed as shown: 4. x 3 mm or longer Self Drilling Screw Phillips Pan Head for attaching structural wall angle, lateral support bar 400 mm
More informationSECTION NON-STRUCTURAL METAL FRAMING
SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationStandard Installation Fire Damper Models: 119, 119(F), 119(SS), D19
Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Page 1 or 8 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the
More informationInstallation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)
Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIP SPECIFICATIONS Width...1.00 inch Height...1.06 inch Length...3.86 inch Weight....025 lbs Max Spacing...48
More informationHOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES
HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES 1 METAL OR TIMBER? When creating stud partitions, wall linings and suspended ceilings the traditional method of installation has been
More informationOmniFlex 300 Plus Installation Instructions
OmniFlex 300 Plus Installation Instructions IMPORTANT PortaFab advises a thorough reading of these instructions before beginning installation. INTRODUCTION Instructions should be read thoroughly and cross-referenced
More informationinstallation instructions Combination Fire & Smoke Damper
Combination Fire & Smoke Damper Sleeve Fire Rated Partition Retaining Angle Combination Fire & Smoke Damper Actuator General Notes: Combination Fire & Smoke Dampers are approved for use in static or dynamic
More informationSuspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F
NWCB Technical Document SUSPENDED CEILINGS 401 Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F 10/09 This document has been revised based on current Building Code standards.
More informationSECTION (09512) - ACOUSTICAL TILE CEILINGS
SECTION 09 51 23 (09512) - ACOUSTICAL TILE CEILINGS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Suspended Metal Grid Systems Complete With Wall Trim 2. Suspended Fiberglass Grid Systems Complete
More informationSUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)
1 5 32 " 2" 27 32 " REQUIRED FOR 1 1 4 " 113 32 " 2 21 32 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 12
More informationOptima Vector Ultima Vector
CEILING&WALL SYSTEMS Between us, ideas become reality Optima Ultima Installation Instructions ceiling panel items: OPTIMA: 3900, 3901, 3902, 3903, 3904, 3905, 3906, 3907, 3908, 3909 ULTIMA: 1920, 1921
More informationSeismic Suspension System Solutions
Seismic Suspension System Solutions Technical Guide CertainTeed Ceilings Acoustic Ceilings & Suspension Systems PURPOSE OF SEISMIC INSTALLATION REQUIREMENTS FOR SUSPENDED CEILINGS Provide a suspension
More informationPanel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing
EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing
More information4 " " SEE DETAIL B1.2. SPECIFICATIONS (unless noted otherwise)
REQUIRED FOR DETAIL 7 1 8 " 7 8 " SUSPENSION REQUIREMENTS SEE DETAIL B1.2 8" 7 1 1 8 " 4 " 2 1 8 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT
More informationSECTION DRYWALL GRID LINEAR LIGHTING INTEGRATION
SECTION 09 22 26 DRYWALL GRID LINEAR LIGHTING INTEGRATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general conditions of Contract, including General and Supplementary Conditions and Divisions-1
More informationTechnical Services Information Bureau
Technical Services Information Bureau INSTALLING ACOUSTICAL LAY-IN TYPE CEILINGS IN SEISMIC REGIONS AUGUST 2009 UPDATED MAY 2017 TECHNICAL BULLETIN This document covers the installation practices recognized
More informationWOODWORKS Concealed. Ceiling Systems. Technical Guide
Ceiling Systems Between us, ideas become reality WOODWORKS Concealed Ceiling Systems Technical Guide This booklet provides drawings, details, and specification information for WoodWorks Concealed ceilings.
More informationOCALA INTERNATIONAL AIRPORT MBI PN: GENERAL AVIATION TERMINAL JANUARY 16, 2018 ADDENDUM-ISSUE
SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More information1. Include plans, elevations, sections, details, and attachments to other work.
SECTION 102213- PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationRENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11
SECTION 09 29 00 GYPSUM BOARD 05/11 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text
More informationwhere high efficiency is the standard
Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional
More informationInstalling the decking 1. An edge clip is screwed to one end of the joists before installing the decking. Designed to enjoy life
ELEGRO decking installation guide ELEGRO decking board measurements: thickness 32mm / width 142mm / length 3000mm. ELEGRO decking can be cut and drilled like timber. It is recommended that decking boards
More informationA. This Section includes acoustical panel ceilings installed with exposed suspension systems.
SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification
More informationDETAIL INSTRUCTION No. 1
BEFORE BEGINNING INSTALLATION, PLEASE READ THROUGH ALL INSTRUCTIONS. Uncrate shipment and check against packing list to insure all materials are included before beginning installation. If any discrepencies
More informationStore No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS
SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationImpression Graphic panels
Impression Graphic panels Installation Guidelines 6003.I Rev. 02 8/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to
More informationSECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL
SECTION 09511 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 DESCRIPTION: A. Work under this section is subject to requirements of the Contract Documents including the General Conditions and Supplementary
More informationCI/SfB. June RockLink 24 Monolith. Installation system
I/SfB (35) Xh2 June 2008 RockLink 24 Monolith Installation system RockLink 24 Monolith Gypsum / MF plasterboard border Rockfon s with edge detail D in module size x are suit able for installation using
More informationSECTION LINEAR METAL CEILINGS
SECTION 09 5423 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply
More informationInstallation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)
Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) 3" RESILMOUNT A237R SPECIFICATIONS 1d " f" Width...1.375 inch Height...3.25 inch Depth...1.125 inch Weight....025
More informationCurrent Seismic Code Development and Adoption
Current Seismic Code Development and Adoption Purpose of Installation Requirements for Suspended Ceilings Provide a suspension system strong enough to resist lateral forces imposed upon it without failing
More informationInstallation Guide and Safety Manual
Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) REQUIRED FURRING CHANNEL REQUIRED FURRING CHANNEL* 1 4" 2 2" Minimum f" Gauge:...25 Gauge With Hemmed Edge (Do Not
More informationSection GYPSUM DRYWALL
Section 09250 GYPSUM DRYWALL 1.00 GENERAL: A. Gypsum Association Specification GA216 and manufacturer's instruction (whichever is more stringent). 2.00 DRYWALL MATERIALS: A. Exposed Gypsum Board: ASTM
More informationWOODWORKS Vector Panels
WOODWORKS Vector Panels Assembly and Installation Instructions Item # Description Included with panels WoodWorks Vector Panels Required for Install Sold by the Pcs/Ctn 5401 24 x 24 x 3/4" panel Ctn 16
More informationResysta Wall Cladding Installation Guidelines
Resysta Wall Cladding Installation Guidelines NOTE: Proper planning of the wall cladding layout is essential for ease of installation of wall cladding boards and wall cladding components. Thoroughly read
More informationConstruction Standards PAGE
Construction Standards PAGE 092613-1 SECTION 092613 - PART 1 - GENERAL 1.1 M.S.U. ISSUES A. It is the intent of MSU that all gypsum veneer plaster used on its projects will comply with LEED NC 3 Credit
More informationA. Flat corner wall-to-wall See page 8. C. Outside corner wall-to-wall See page 8. B. Inside corner kit wall-to-wall See page 7
System Overview These instructions review how to install drywall versions of TruGroove recessed corners. Please refer to layout drawings supplied by Philips Ledalite with these installation instructions.
More informationBanyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL
SECTION 09511 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationAXIOM Indirect Field Light Coves
AXIOM Indirect Field Light Coves Assembly and Installation Instructions 1. GENERAL 1.1 Description The Axiom Indirect Field Light Cove system is a pre-engineered lighting solution designed to be used at
More informationInstallation guide. ROCKFON System Z mm. 600 mm
Installation guide 600 mm ROCKFON tiles with the D edge detail are suitable for installation using this system. The following ceiling tile module sizes (mm) can be used with : 1500 x 600 1800 X 600 100
More informationMETALWORKS Torsion Spring
METALWORKS Torsion Spring Assembly and Installation Instructions 1. GENERAL 1.1 Product Description MetalWorks Torsion Spring is a downward accessible aluminum ceiling panel available in standard 2' x
More informationEI 30 barriere Self contained fire protection EI 30 from above and below smoke impervious EN
O W A c e i l i n g i n f o r m a t i o n OWAcoustic EI 0 barriere Self contained fire protection EI 0 from above and below smoke impervious EN 4- Self contained fire protection EI 0 EI 0 barriere A Element
More informationDuct Wrap Flexible Wraps
Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone
More informationULTIMA Vector SAHARA Vector
TECHNICL DTSHEET CI/Sf (35) Xy 10/2009 CEILING SYSTEMS etween us, ideas become reality Surface Finish Colour ULTIM: Lightly textured, unperforated, non-directional surface. Factory applied treatment for
More informationTrench Duct Class Catalog 5230CT9601R10/08
5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11
More informationRSIC-1-INSTALALTION GUIDE RSIC-1 SOUND ISOLATION CLIP
RSIC-1 Drywall Furring Channel: Minimum Requirements: 25 gauge, hemmed edge detail required on all 25 gauge furring channel. Meets or exceeds SFIA requirements. Depth: 7/8 inch Width Bottom: 2-9/16 to
More informationCEILING SYSTEMS. What You Need to Know The Basics NEW Armstrong Seismic Rx A Code-Compliant Solution
CS3543 Seismic installation Rev7 8/23/06 10:53 AM Page 1 CEILING SYSTEMS What You Need to Know The asics NEW Armstrong Seismic Rx A Code-Compliant Solution Purpose of Installation Requirements for Suspended
More informationSECTION GYPSUM BOARD
SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable
More informationCERTIFICATE OF APPROVAL No CF 429 PROMAT UK LTD
CERTIFICATE OF APPROVAL No CF 429 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of The Sterling Centre,
More informationSECTION ACOUSTICAL CEILING SYSTEMS
SECTION 09 51 13 PART 1 - GENERAL 1.01 SUMMARY A. This Section includes the following: 1. Ceilings consisting of acoustical panels and exposed suspension systems. 2. T-Bar mounted light fixture support
More informationOPTIMA, ULTIMA, and LYRA Vector
OPTIMA, ULTIMA, and LYRA Assembly and Installation Instructions CEILING PANEL ITEMS: OPTIMA: 3900, 3900PB, 3901, 3902, 3903, 3904, 3905, 3906, 3907, 3908, 3908PB, 3909 Non-directional ULTIMA: 1920, 1921
More informationVentura Office Partitions. Technical guide
Office Partitions Technical guide - General Despite its minimalistic and sleek design, is a genuine, relocatable office partition in line with other products in the Triplan system. This relocatable office
More informationINSTALLATION MANUAL SURFACE-MOUNTED HEADWALL
INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL Model # Series 7200-S Top Mounting Plate Electrical Junction Box Located Behind Removable Upper Panel Medical Gas Connections Lower Mounting Plate OVERVIEW
More informationInstallation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips)
Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips) 1d" 2 2" 1 4" f" QUIETCLIP SPECIFICATIONS Width...1.25 inch Height...4.25 inch Depth...1 inch Weight....025 lbs Max Spacing...48
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 095113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 DEFINITIONS A. AC: Articulation
More informationConstruction Standards PAGE
Construction Standards PAGE 083113-1 SECTION 083113 - PART 1 - GENERAL 1.1 M.S.U ISSUES A. M.S.U. avoids access doors whenever possible by using lay-in type ceilings, but all valves and equipment requiring
More informationOptimA, Ultima, CALLa, and LYRA Vector
OptimA, Ultima, CALLa, and LYRA Vector Assembly and Installation Instructions ceiling panel items: OPTIMA: 3900, 3900PB, 3901, 3902, 3903, 3904, 3905, 3906, 3907, 3908, 3908PB, 3909 Non-directional ULTIMA:
More informationMetal Building Roof Curbs
Metal Building Roof Curbs 54 years of excellence... www.thybar.com 129 Metal Building Roof Curbs Table of Contents General Information 131 Specifications 132-133 Layout 134-135 Assembly Instructions 136-137
More informationINSTALLATION INSTRUCTIONS FOR PLASCORE L2550 LINER WALL
INSTALLATION INSTRUCTIONS FOR PLASCORE L2550 LINER WALL The following information is provided by Plascore, Inc., as a general guideline for the installation of the L2550 Liner Wall System. This information
More informationSECTION ACOUSTICAL CEILINGS
SECTION 09511 ACOUSTICAL CEILINGS PART 1 GENERAL 1.01 SECTION INCLUDES A. Acoustical ceiling panels. B. Exposed grid suspension system. C. Wire hangers, fasteners, main runners, cross tees, and wall angle
More informationfor FD & DFD 150X MODELS
Part #45946 Installation, Operation and Maintenance Instructions FD and DFD 150X Series models are intended for installation in accordance with fire damper requirements established by: National Fire Protection
More informationProject No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6
DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00
More informationDIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3336 Reissued 01/2017 This report is subject to renewal 01/2019. DIVISION: 09 00
More informationSECTION AIR OUTLETS AND INLETS
PART 1 - GENERAL 1.1 DESCRIPTION A. Roof Curbs SECTION 23 37 00 AIR OUTLETS AND INLETS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph
More informationRULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
12/6/2012 RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS PART 1 - GENERAL A. The Wood Square Suspended Ceiling Systems covered by this specification shall be the products of the
More information1. Seismic Loads: Reference structural drawings.
SECTION 102213 ~WIRE MESH PARTITIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationROCKFON SYSTEM T24 A/E
System description ROCKFON SYSTEM T24 A/E Versatile ceiling system Quick and easy to install Visible grid Easy integration with services and fittings Ceiling comprising Chicago Metallic T24 Click 2890
More informationAxiom Building Perimeter System
Ceiling Systems Between us, ideas become reality Axiom Building Perimeter System Assembly and Installation Instructions 1 GENERAL 1.1 Description The Axiom Building Perimeter System (AXBPS) is a preengineered
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationInstall Instructions. Helix Z1. Important Information. Important:
Congratulations, you have just purchased the highest quality entrance mat available. Proper installation is necessary to ensure that your warranty will be honored by Impact Specialties. Important Information
More informationECONO 200 INPLANT OFFICE
Warehouse Storage & Material Handling Equipment+ ECONO 200 INPLANT OFFICE INSTALLATION & ASSEMBLY INSTRUCTIONS American Surplus Inc. 1 Noyes Ave. East Providence, RI Phone: (800) 989-7176 Fax: (401) 434-7414
More informationSTANDARD PRODUCTS - CUSTOM LOOK
AXIOM ClOUDS STANDARD PRODUCTS - CUSTOM LOOK AXIOM AXIOM can give your next space a unique and crisp feel. The AXIOM family offers dramatic visuals with a variety of flat vertical trims and design profiles.
More informationSECTION AXIOM INDIRECT FIELD LIGHT COVE PERIMETER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 09 51 13 AXIOM INDIRECT FIELD LIGHT COVE PERIMETER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general conditions of Contract, including General and Supplementary Conditions and
More informationOPTIMA Vector ULTIMA Vector
OPTIMA ULTIMA Assembly and Installation Instructions CEILING PANEL ITEMS: OPTIMA: 3900, 3900PB, 3901, 3902, 3903, 3904, 3905, 3906, 3907, 3908, 3908PB, 3909 ULTIMA: 1920, 1921 ULTIMA Create! : Z1920UC1
More informationLED. P43 Recessed Linear 4 Slot IDENTIFYING FIXTURES INSTALLATION NOTES ROW MOUNTING X1, X2, X6
MOUNT PERIME TROFFER X1, X2, X6 T-BAR 8-32_X_3_8_H OVERHEAD JOINER SEAM ALIGNER PARTS (SHIPPED SEPARATELY) OVERHEAD OVERHEAD FLSH-X1 FLSH-X2 FLSH-X6 WTW #8 x 3/8 HWH Self Tap Screw #10 x.1875 SMS #10 x.1875
More informationTECTUM Lay-in and Tegular Ceiling Panels Assembly and Installation Instructions for 1-Inch Thick Standard Lay-in and Tegular Ceiling Panels
TECTUM Lay-in and Tegular Ceiling Panels Assembly and Installation Instructions for 1-Inch Thick Standard Lay-in and Tegular Ceiling Panels TECTUM LAY-IN & Tegular CEILING PANELS STANDARD ITEMS: Item No.
More information