Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing JACKETED /
|
|
- Oswald Ramsey
- 6 years ago
- Views:
Transcription
1 Multijacketed Tubing, Jacketed Tubing, Insulated Tubing 1 Multijacketed Tubing, Single-Jacketed Tubing, Insulated Tubing Features 1/4 to 6 to 12 tubing sizes available in 316/316L stainless steel copper Seamless welded tubing available in stainless steel Thermoplastic polyurethane (TPU) PVC jackets help protect tubing from external corrosion abrasion Fibrous glass insulation reduces heat loss helps protect personnel
2 2 Tubing, Tubing Tools, Welding System Multijacketed Tubing Swagelok multijacketed tubing provides protection against galvanic atmospheric corrosion protects the tubing against wear abrasion. In addition, it reduces costs by enabling installation of up to four tubes at once. Features 316/316L stainless steel instrumentation tubing 1/4 to 6 to 12 tubing sizes Low-temperature, UV-resistant thermoplastic polyurethane (TPU) for both individual tube jackets outer jacket Positive identification of individual tubes along entire length jacket marking stard; see Stard Marking, below. Individual tubes are marked for positive identification along their entire length. Materials of Construction Component Tubing Jackets Material/Grade 316/316L / ASTM A269, A213➀ Thermoplastic polyurethane Stiffening plate Aluminum 33- Inner wrap, outer wrap Foam wrap Polyester film Closed cell, EPDM foam rubber ➀ wall thickness, not minimum wall thickness. Seamless metric sizes also meet DIN test 1 class material 1.441/ Stard Marking Stard marking includes model, size, materials, specifications, temperature rating, batch number for traceability. Individual Example: Swagelok Model MJT /316L SMLS ASTM A269 TPU Jacket Maximum 25/12 Caution May Be Hot Batch Outer Jacket Example: 6 ft Swagelok Model MJT Two /316L SMLS ASTM A269 TPU Jacket Maximum 25/12 Caution May Be Hot Batch Technical Data Fractional Tubing Data Max Process For additional information, see Swagelok Tubing Data (MS-1-7). For jacket properties information, see page 5. Pressure Rating at 2 to psig 1/ /8.35 service; ➀ installation ➀ Not recoended for use with tube fittings in gas service. Metric Max Process Min Bend Radius Support Centers ft Seamless Welded Horiz Vert Pressure Rating at 28 to 37 bar Min Bend Radius cm Support Centers m Seamless Welded Horiz Vert service; installation 2 16 Dimensions Dimensions are for reference only are subject to change. W H H W, Width Height Weight Max Bulk Length Dimensions lb/ft ft 4 1/ / Dimensions kg/m m
3 Single-Jacketed Tubing Swagelok single-jacketed tubing helps provide increased protection against galvanic atmospheric corrosion. In addition, it helps protect the tubing against wear abrasion. Multijacketed Tubing, Jacketed Tubing, Insulated Tubing 3 Features 316/316L stainless steel copper instrumentation tubing 1/4 to 6 to 12 tubing sizes Low-temperature, UV-resistant PVC jacket stard; optional thermoplastic polyurethane (TPU) jacket available for higher-temperature service Jacket marking available; see Optional Jacket Marking, below. Technical Data Fractional Max Process Pressure Rating at Min Support Max Bulk Length 2 to Bend Centers Jacket ± % psig Radius ft Weight ft Seamless Welded Horiz Vert lb/ft Seamless Welded Stainless Steel (ASTM A269, A213➀, TP 316/316L) 1/ , PVC 3, /8.35 jacket; service; ➁ 25, TPU, jacket installation Copper (ASTM B68, B68M, B75, UNS 122) 1/4.3 22, PVC 3, /8.32 jacket; service; ➁ 25, TPU, jacket installation ➀ wall thickness, not minimum wall thickness. ➁ Not recoended for use with tube fittings in gas service. Metric Max Process Pressure Rating at Min Support Max Bulk Length 28 to 37 Bend Centers Jacket ± % bar Radius m Weight m Seamless Welded cm Horiz Vert kg/m Seamless Welded Stainless Steel (ASTM A269, A213➀, TP 316/316L) 6 4, PVC 34, jacket; service; 121, TPU 23, jacket installation Copper (ASTM B68, B68M, B75, UNS 122) , PVC 34, jacket; service; , TPU 23, 12 1.➁ jacket installation ➀ wall thickness, not minimum wall thickness. Seamless metric sizes also meet DIN test 1 class material 1.441/ ➁ Not recoended for use with tube fittings in gas service. Optional Jacket Marking Optional marking includes model, size, materials, specifications, temperature rating, batch number for traceability. Example: ft Swagelok Model JT /316L SMLS ASTM A269 PVC Jacket Maximum 22/4 Caution May Be Hot Batch Tubing Data For additional information, see Swagelok Tubing Data (MS-1-7). For jacket properties information, see page 5.
4 4 Tubing, Tubing Tools, Welding System Insulated Tubing Swagelok insulated tubing is designed for use in applications such as steam supply, condensate return, gas liquid transport lines, where weatherproofing energy conservation are important. Swagelok insulated tubing helps protect personnel from hot process steam lines, reduces heat loss, offers a cost-effective alternative to field-installed insulation of small-diameter tubing systems. Features 316/316L stainless steel copper instrumentation tubing 1/4 to 6 to 12 tubing sizes Low-temperature, UV-resistant PVC jacket stard; optional TPU jacket available Absorption-resistant fibrous glass insulation Insulation contains less than ppm of water-soluble chlorides Jacket marking stard; see Stard Jacket Marking, below. Seal insulation ends to prevent contamination of the insulation. Technical Data Fractional Max Process Pressure Rating at Min Support Max Bulk Length 4 Bend Centers Jacket ± % psig Radius ft Weight ft Seamless Welded Horiz Vert lb/ft Seamless Welded Stainless Steel (ASTM A269, A213➀, TP 316/316L) 1/4.35 3, /8.35 service; ➂ ➁, installation Copper (ASTM B68, B68M, B75, UNS 122) 1/4.3 3, /8.32 service; ➂ ➁, installation ➀ wall thickness, not minimum wall thickness. ➁ Not recoended for use with tube fittings in gas service. ➂ The maximum jacket surface temperature is 14 with a process temperature of 4, an ambient temperature of 8, a wind of mph. Metric Max Process Pressure Rating at Min Support Max Bulk Length 24 Bend Centers Jacket ± % bar Radius m Weight m Seamless Welded cm Horiz Vert kg/m Seamless Welded Stainless Steel (ASTM A269, A213➀, TP 316/316L) 6 34, service; 1. 24➁ 23, installation Copper (ASTM B68, B68M, B75, UNS 122) , service; 1. 24➁ , 12 1.➂ installation ➀ wall thickness, not minimum wall thickness. Seamless metric sizes also meet DIN test 1 class material 1.441/ ➁ The maximum jacket surface temperature is 6 with a process temperature of 24, an ambient temperature of 26, a wind of 16 km/h. ➂ Not recoended for use with tube fittings in gas service. Stard Jacket Marking Stard marking includes length, ordering number, temperature rating, batch number for traceability. Example: ft Swagelok SS ST4 S 35 U 4/24 Continuous Batch Tubing Data For additional information, see Swagelok Tubing Data (MS-1-7). For jacket properties information, see page 5.
5 Insulated Tubing Heat Loss Multijacketed Tubing, Jacketed Tubing, Insulated Tubing 5 The information presented represents typical performance data for low-temperature PVC TPU jackets for the conditions given. Actual results may vary with the conditions of installation. Heat loss calculated with 25 mph (4 km/h) wind. 1/4 6 Tubing 12 Tubing Heat Loss, Btu/h ft Ambient, Heat Loss, Kcal/h m Heat Loss, Btu/h ft Ambient, Heat Loss, Kcal/h m Ambient, Ambient, 3/8 Tubing Heat Loss, Btu/h ft Ambient, Heat Loss, Kcal/h m Legend 2 psig (13.7 bar) steam 388 (197) 125 psig (8.6 bar) steam 353 (178) 5 psig (3.4 bar) steam 299 (148) 15 psig (1. bar) steam 25 (121) Ambient, Jacket Properties Jacket Properties Low- PVC Thermoplastic Polyurethane (TPU) Tensile strength 22 psi (151 bar) 38 psi (261 bar) Elongation 35 % 7 % Hardness, Shore A 8 8 Maximum temperature 22 (4) 25 (121) Minimum installation temperature ( 23) 4 ( 4) Minimum service temperature 3 ( 34) 67 ( 55) Halogenated (chlorides) Yes No Water absorption. % 1.2 to 1.4 % Flame resistance UV resistance 24 rating in accordance with ASTM D h in accordance with UL-1581 V2 in accordance with UL94 2 h in accordance with QUV aging test
6 6 Tubing, Tubing Tools, Welding System Ordering Information Multijacketed Tubing Build a multijacketed tubing ordering number by combining the designators in the sequence shown below. A Material SS = 316/316L stainless steel 25M = 316L stainless steel with 2.5% Molybdenum (Fractional only) B Model MJT = Multijacketed C Number of 2 = 2 tubes of same size 3 = 3 tubes of same size 4 = 4 tubes of same size A B C D E F S S - M J T S F 1 D Size: Seamless Stainless Steel, Fractional 4-S-35 = 1/ S-35 = 3/ S-35 =.35 8-S-49 =.49 Seamless Stainless Steel, Metric 6M-S-1.M = 6 1. M-S-1.M = 1. 12M-S-1.M = Welded Stainless Steel, Fractional 4-W-35 = 1/ W-35 = 3/ W-35 =.35 8-W-49 =.49 Welded Stainless Steel, Metric 6M-W-1.M = 6 1. M-W-1.M = 1. 12M-W-1.M = E Package Length Unit of Measure F = Feet M = Meters F Package Length, Tolerance Specify a bulk length up to the maximum bulk length shown on page 2. 1 = Continuous length, ± 5 % (contains one piece) 2 = Exact length, ±.5 % (may contain multiple pieces) 3 = Continuous, exact length, ±.5 % (contains one piece) 4 = Stard length, ± 5 % (may contain multiple pieces) Single-Jacketed Insulated Tubing Build a single-jacketed or insulated tubing ordering number by combining the designators in the sequence shown below. A Material CU = Copper SS = 316/316L stainless steel 25M = 316L stainless steel with 2.5% Molybdenum (Fractional only) B Model JT = Single-jacketed ST = Insulated A B C D E F S S - S T 4 - S U - G C Size: Copper, Fractional 4-3 = 1/ = 3/ = =.49 Copper, Metric 6M-1.M = 6 1. M-1.M = 1. 12M-1.M = M-1.5M = Seamless Stainless Steel, Fractional 4-S-35 = 1/ S-35 = 3/ S-35 =.35 Seamless Stainless Steel, Metric 6M-S-1.M = 6 1. M-S-1.M = 1. 12M-S-1.M = Welded Stainless Steel, Fractional 4-W-35 = 1/ W-35 = 3/ W-35 =.35 Welded Stainless Steel, Metric 6M-W-1.M = 6 1. M-W-1.M = 1. 12M-W-1.M = D Package Length Fractional = ft (3.5 m) 25 = 25 ft (76.2 m) 5 = 5 ft (152 m) xxxx = Bulk length➀ Metric 3M = 3 m (98.4 ft) 75M = 75 m (246 ft) 15M = 15 m (492 ft) xxxx = Bulk length➀ ➀ See pages 3 4 for the maximum bulk length of tubing available. E Options For multiple options, add designators in alphabetical order. M = Jacket marking, 6 ft (2 m) intervals (model JT only; see page 3 for details) U = TPU jacket (required for color jacket) F Jacket Colors None = Black A = Grey B = Blue G = Green N = Orange P = Purple R = Red W = White Y = Yellow
7 Multijacketed Tubing, Jacketed Tubing, Insulated Tubing 7 Options Tubing Material Size Other materials sizes are available. Contact your authorized Swagelok representative. For maximum sizes available see table. Tubing Size Tubing Material () Jacketed 1 (25.4) Insulated 3/4 (19.1) 1 tube 1 (25.4) Multijacketed 2 tubes 3/4 (19.1) 3 tubes 5/8 (15.9) 4 tubes (12.7)) Accessories Heat-Shrink Adhesive-Lined Sleeves Used to protect bare tubing straight fitting connections to jacketed insulated tubing, these sleeves contain a heat-activated adhesive to provide a watertight seal to the protected area. Sleeve Description.75 (19. ) dia, shrinks to.2 (5.1 ) dia 1. (25.4 ) dia, shrinks to.3 (7.6 ) dia 2. (5.8 ) dia, shrinks to.75 (19. ) dia 3. (76.2 ) dia, shrinks to 1. (25.4 ) dia Ordering Number MS-HSB-S75 MS-HSB-S MS-HSB-S2 MS-HSB-S3 Multijacketed Tubing Heat-Shrink Sleeve Selection Heat Shrink Boot Ordering Number 1/4 MS-HSB-S MS-HSB-S2 MS-HSB-S2 3/8 MS-HSB-S2 MS-HSB-S2 MS-HSB-S3 MS-HSB-S3 MS-HSB-S3 MS-HSB-S3 6 MS-HSB-S MS-HSB-S2 MS-HSB-S2 8 MS-HSB-S2 MS-HSB-S2 MS-HSB-S2 MS-HSB-S2 MS-HSB-S2 MS-HSB-S3 12 MS-HSB-S3 MS-HSB-S3 MS-HSB-S3 Silicone Sealing Tape Silicone sealing tape is used in conjunction with heat-shrink sleeves to seal the ends of jacketed insulated tubing where the jacket material needs to be removed to assemble a fitting. Each roll is ft (3. m) long 1.5 (38.1 ) wide. Ordering number: MS-SR-B Silicone Sealant This silicone RTV sealant is used in conjunction with heatshrink sleeves to seal ends of jacketed insulated tubing from moisture, it offers excellent resistance to weather, oil, many chemicals. One tube will seal approximately ends; each kit contains 8 tubes. Service : 6 to 4 ( 51 to 24) Cure Time: approximately 24 h at 77 (25) 5 % relative humidity Ordering number: MS-RTV-SEAL-KIT Jacket Patch Kit The jacket patch kit can be used to seal a splice in tubing or to repair any incidental field damage to insulation jacket. Each kit contains thermal insulation, fiberglass tape, self-sealing patches. Ordering number: MS-JP-KIT Weatherproof Strip Insulation Weatherproof strip insulation provides an effective method of temporarily insulating components. The jacketed insulation is universal easy to install. It is approximately 4 (2 ) wide (12.7 ) thick is available in stard lengths of, 3, 5 ft (3., 9.1, 15.2 m) packages. Insulation Item Ordering Number ft (3. m) insulation strip MS-SI- 3 ft (9.1 m) insulation strip MS-SI-3 5 ft (15.2 m) insulation strip MS-SI-5 25 insulation tie straps MS-SITS-KIT Heat-Shrink End-Seal Boots (Insulated Tubing) Made of thermally stabilized, modified polyolefin, these heat-shrinkable boots provide a weatherproof end seal for all sizes of insulated tubing protect against moisture ingress. Each kit contains 2 end-seal boots. Ordering number: MS-HSB-KIT Caps (Insulated Tubing) Protective end caps temporarily seal insulated tubing ends insulatation during storage installation. Each kit contains 2 caps. 1/4 3/8 Ordering Number 6 MS-46-CAP-KIT 12 MS-8-CAP-KIT
8 8 Tubing, Tubing Tools, Welding System Accessories Mounting Clips Stainless steel mounting clips secure jacketed tubing to brackets or tubing trays. Clips consist of a 1/4 x 2 bolt nut two 1/4 washers. When using strut-type mounting brackets, also order strut nuts, below. Tools Breakout Bending Tools The tube breakout bender is used with multijacketed tubing to separate bend individual tubes up to or 12 outside diameter. Breakout Bender The bending tools are used to bend 2-, 3-, or 4-tube multijacketed tubing or insulated tubing bundles with up to or 12 outside diameter tubes. Multijacketed 1/4 6 3/8 8, 12 Strut Nuts Number of Ordering Number 2 MS-K42 3 MS-K43 4 MS-K44 2 MS-K62 3 MS-K63 4 MS-K64 2 MS-K82 3 MS-K83 4 MS-K84 Strut nuts are used when securing jacketed tubing to strut-type mounting brackets Ordering number: MS-M65-4 Single-Jacketed Ordering Number 1/4 6 MS-K41 3/8 8 MS-K61, 12 MS-K81 Description breakout bender,➀ 1.75 (44.4 ) radius Bending tool,➁ 8 (2 cm) radius Bending tool,➁ 12 (3 cm) radius Ordering Number MS-BT1 MS-BBT MS-BBT-12 ➀ Requires square drive ratchet, not included. ➁ Requires 3/4 NPT threaded hle, not included. Combination Spool St/Bundle Straightener This tool safely pays out straightens spooled coils of jacketed or insulated tubing. It accepts stard 6 (152.4 cm) spool diameters up to 36 (91 cm) wide. Dimensions: 55.5 H by 5 W by 78 D (14.97 H by 127 W by D cm) Ordering number: MS ST636 Related Products Jacketed Connector (JTC) For use with 1/4, 3/8, jacketed tubing with up to 1/16 nominal jacket thickness Available in all stard tube fitting configurations Provides a leak-tight seal on the tubing jacket preventing environmental ingress See the Swagelok Jacketed Connector (JTC) catalog, MS Five-Roll Straightener The straightener can be mounted to the spool st for use with single, coiled jacketed or nonjacketed tubing up to or 12 outside diameter. Case dimensions: 16 H by 19.5 W by 7.5 D (4.6 H by 49.5 W by 19 D cm) Ordering number: MS TST12 (case included for 1/4 to ) MS TST24 (case not included for 1/4 to ) MS-2-188, RevI, October 217
9 About this document Thank you for downloading this electronic catalog, which is part of General Product catalog Swagelok published in print. This type of electronic catalog is updated as new information arises or revisions, which may be more current than the printed version. Swagelok Company is a major developer provider of fluid system solutions, including products, integration solutions services for industry research, instrumentation, pharmaceutical, oil gas, power, petrochemical, alternative fuels, semiconductor. Our manufacturing facilities, research, service distribution facilities support a global network of more than 2 authorized sales service centers in 57 countries. Visit to locate your Swagelok representative obtain any information on features, technical information product references, or to learn about the variety of services available only through authorized sales centers service Swagelok. Safe Product Selection When selecting a product, the total system design must be considered to ensure safe, trouble-free performance. Function, material compatibility, adequate ratings, proper installation, operation, maintenance are the responsibilities of the system designer user. Warranty Information Swagelok products are backed by The Swagelok Limited Lifetime Warranty. For a copy, visit your Swagelok Web site or contact your authorized Swagelok representative. Swagelok, Ferrule-Pak, Goop, Hinging-Colleting, IGC, Kenmac, Micro-Fit, Nupro, Snoop, Sno-Trik, SWAK, VCO, VCR, Ultra- Torr, Whitey TM Swagelok Company Aflas TM Asahi Glass Co. Ltd. AL-6XN TM Allegheny Ludlum Corporation AutoCAD TM Autodesk, Inc. CSA TM Canadian Stards Association DeviceNet TM VA Kalrez, Krytox TM DuPont Elgiloy TM Elgiloy Specialty Metals FM TM FM Global Grafoil TM GrafTech International Holdings, Inc. MAC TM MAC Valves Inc. Microsoft, Windows TM Microsoft Corp. NACE TM NACE International Nitronic TM AK Steel Corporation picofast TM HansTurck KG Pillar TM Nippon Pillar Packing Company, Ltd. Rapid Tap TM Relton Corporation 15-7 PH, 17-7 PH TM AK Steel Corp. Svik TM SvikAB Silconert TM Silcotek Corporation Simriz TM Freudenberg-NOK SolidWorks TM SolidWorks Corporation 217 Swagelok Company
Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing
www.swagelok.com Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing Features 1/4 to in. and 6 to 12 tubing sizes available in 316/316L stainless steel and copper Seamless and welded tubing
More informationMultijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing
Multijacketed Tubing, Single-Jacketed Tubing, Insulated Tubing 1 www.swagelok.com Multijacketed Tubing, Single-Jacketed Tubing, Insulated Tubing Features 1/4 to 6 to 12 tubing sizes available in 316/316L
More informationUltrahigh-Purity (UHP) and High-Purity Stainless Steel Tubing
Ultrahigh-Purity (UHP) and High-Purity Stainless Steel Tubing Fractional, Metric, and 1 www.swagelok.com Ultrahigh-Purity (UHP) and High-Purity Stainless Steel Tubing Fractional, Metric, and 316L stainless
More informationStainless Steel Seamless Tubing and Tube Support Systems
Stainless Steel Seamless Tubing Fractional, Metric, and Imperial Sizes 1 Stainless Steel Seamless Tubing and Fractional, Metric, and Imperial Sizes 316 / 316L and 304 / 304L stainless steel Standard instrumentation
More informationTubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness
Tubing Data 1 www.swagelok.com Tubing Data Contents Tubing Selection... 1 Tubing Handling.... 1 Gas Service... 2 Tubing Installation.... 2 Suggested Allowable Working Pressure Tables Carbon Steel Tubing...
More informationLeak Detectors, Lubricants, and Sealants
Leak Detectors, Lubricants, and Sealants 1 www.swagelok.com Leak Detectors, Lubricants, and Sealants Products Snoop liquid leak detectors Goop thread lubricants SWAK, PTFE Tape, and PTFE-Free pipe thread
More informationPre-Insulated Tubing Bundles
www.swagelok.com Pre-Insulated Tubing undles Electric-Traced and Steam-Traced Features Simplified field installation 1/8 to 3/4 in. and 6 to 12 mm seamless or welded tubing sizes 316 / 316L stainless steel,
More informationWeld Fittings. Ultrahigh-Purity, Specially Cleaned, and Industrial. 1/8 to 1 in. and 6 to 18 mm
Weld Fittings Ultrahigh-Purity, Specially Cleaned, and Industrial 1 www.swagelok.com Weld Fittings Ultrahigh-Purity, Specially Cleaned, and Industrial WE 1/8 to 1 in. and to 18 mm 31, 31, 31 VR, and 31
More informationMetering Valves. S, M, L, and 31 Series. Straight-pattern flow coefficients (C v ) from to Low- and high-pressure service
Metering Valves S, M, L, and 1 www.swagelok.com Metering Valves S, M, L, and Straight-pattern flow coefficients (C v ) from 0.004 to 0.16 Low- and high-pressure service Repeatable vernier handles available
More informationPre-Insulated Tubing Bundles
Pre-Insulated Tubing undles 1 www.swagelok.com Pre-Insulated Tubing undles Electric-Traced and Steam-Traced Features Simplified field installation 1/8 to 3/4 in. and 6 to 12 mm seamless or welded tubing
More informationInsulated Jacketed Tubing
Insulated Jacketed COILED STICK CUT TO LENGTH Pre-Insulated UTC Pre-Insulated tubing is designed for the applications where a minimum heat loss is requested. This product provides a solution for maintaining
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS TRACEPAK TPL AND TPH Technical Specifications Model Number Product Family TPL Preinsulated Light Steam Traced Single Process Tube TPL2 Preinsulated Light Steam Traced Dual Process
More informationSingle-Jacketed Tubing
Single-Jacketed Tubing COILED STICK CUT TO LENGTH UTC Single Jacketed tube Protect the tube against corrosion and pitting in a diverse changing environment and climates. The phenomenon of Chloride Stress
More informationSubsea Weld Fittings WELD
Subsea Fittings G Series 1 www.swagelok.com Subsea Fittings G Series Excellent corrosion resistance in subsea environments 316L, Alloy 625, and Alloy 2507 fittings are NACE MR0175/ ISO 15156 compliant
More informationStainless Steel Seamless Tubing and Tube Support Systems
www.swagelok.com Stainless Steel Seamless Tubing and Fractional, Metric, and Imperial Sizes 316 / 316L and 304 / 304L stainless steel Standard instrumentation tubing 1/8 to 2 and 3 to 25 mm sizes Marked
More informationAnalytical instrumentation mechanical marine
Analytical instrumentation mechanical marine POLYMER COATED TUBING FOR USE IN SYSTEMS WHERE PROTECTION FROM SOURCES OF EXTERNAL CORROSION IS EMPHASIZED Attached you will find a sample specification. It
More informationHeavy Wall Heat Shrinkable Tubing 5-7. Flame Retardant Heavy Wall Heat Shrinkable Tubing 8. Heat Shrinkable Ends Caps 9
Heavy Wall Heat Shrinkable Tubing 5-7 Flame Retardant Heavy Wall Heat Shrinkable Tubing 8 Heat Shrinkable Ends Caps 9 Heat Shrinkable Breakout Boots 10 Shrink Ratio 3:1 Shrink-Kon Heavy Wall Heat Shrinkable
More informationA. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.
SECTION 230719 - HVAC PIPING INSULATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Piping insulation. B. Jackets and accessories. 1.2 RELATED REQUIREMENTS A. Section 07813 - Fire Procection, HVAC & Plumbing
More informationTubes and Pipes. Tubes and Pipes D-02
s and Pipes s and Pipes D-0 D-03 s and Pipes Contents s Tubing Selection Tubing Handling Gas Service Tubing Installation Suggested Allowable Working Pressure Tables Stainless Steel Seamless Tubing Carbon
More informationA. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to provide design guidelines for Utility Direct Buried
More informationK-FLEX SOLAR SYSTEM SOLAR SYSTEM
K-FLEX SOLAR SYSTEM SOLAR SYSTEM K-FLEX offers a line of products designed specifically for solar heating, renewable energy sources used to produce hot water using solar energy. The product range consists
More informationSanitary Pressure Regulators RHPS Series
www.swagelok.com Sanitary Pressure Regulators RHPS Series Pressure-reducing regulators and tank blanketing regulators 316L stainless steel construction 1/2, 1, and 1 1/2 in. end connections Working pressures
More informationProcess Interface Valves
www.swagelok.com Process Interface s Kenmac Series Process Interface s and Process Monoflanges Stainless steel, carbon steel, and duplex stainless steel materials Pressure ratings in accordance with ASME
More informationBundling, Insulating and Sealing Products
Product Facts Plastic cable wrap provides an easy way to bundle cable, wire, tubing or hoses Helps protect bundles against abrasion caused by vibration Coiled wrap allows wiring harness breakouts Nylon
More informationTermco Heatshrink.
Termco Heatshrink Thin Wall Tubing (Flame Retardant) Clear Thin Wall Tubing Green/Yellow Thin Wall Tubing Dual Wall Tubing Medium Wall Tubing Cable End Caps Heat Shrink Miniature End Cap Heat Shrinkable
More informationTubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness
www.swagelok.com Tubing Data Contents Gas Service...................................... 2 Tubing Installation................................. 2 Suggested Allowable Working Pressure Tables Carbon Steel
More informationball valves 7 Series Fire Safe 2-way, 3-piece Bolted Ball Valves
7 Series Fire Safe 2-way, 3-piece Bolted Ball Valves HOKE s 7 Series Fire Safe Valves meet demanding application requirements in the production environment of chemical and petrochemical processing facilities.
More informationFP30112WHITE100 Heat Shrink TW Tubing 100' Spool
FP30112WHITE100 Heat Shrink TW Tubing Minnesota Mining (3M) Catalog Number FP30112WHITE100 Manufacturer Minnesota Mining (3M) Description Tubing, Heat; ; 600 V; Cable Size 1/2 Inch; Thin Wall; Shrink Temperature
More informationPIP INSR1000 Installation of Flexible, Removable/Reusable Insulation Covers for Hot Insulation Service
TECHNICAL REVISION August 2015 Insulation PIP INSR1000 Installation of Flexible, Removable/Reusable Insulation Covers for Hot Insulation Service PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort
More informationPressure Gauges Industrial and Process
Pressure Gauges Industrial and Process PGI Series 4, 5, 63, 1, 115, and 16 mm (1 1/2, 2, 2 1/2, 4, 4 1/2 and 6 in.) dial sizes ccuracy in accordance with SME, EN, and JIS vailable with a variety of end
More informationEFFISUS EASYREPAIR MEMBRANE
Effisus Easyrepair Membrane EFFISUS EASYREPAIR MEMBRANE DESCRIPTION For use on virtually all roofs, Effisus Easyrepair Membrane features an UV stable backing that is available in Black, Gray, Tan, and
More informationParflex Multitube Instrument and Heat Trace Tubing Products. Catalog 4200-M-2 July 2006
Parflex Multitube Instrument and Heat Trace Tubing Products Catalog 4200-M-2 July 2006 General Information Parker Hannifin, World Leader In Bundled Tubing Products The offers an extensive selection of
More informationTRICON DOUBLE-CON PLUS
TRICON DOUBLE-CON PLUS System Specifications Iron Pipe Size Steel Conduit O.D. Steel Conduit Wall Outer Insulation (IN)* Alum./Stainless/Galv. Jacket O.D. (IN) Metal Jacket Wall Thickness 1 4.50.120 1.75
More informationP.O. Box : 3876, Umm Al Quwain-U.A.E. Tel.: , Fax:
Tel.: +971 6 74396, Fax: +971 6 74367 Product Aluminum Foil Tapes A dead soft malleable aluminum foil coated with an aggressive Acrylic & Hotmelt adhesive. superior quick stick at normal temperatures with
More informationLeak Detectors, Lubricants, and Sealants
www.swagelok.com Leak Detectors, Lubricants, and Sealants Products Snoop liquid leak detectors Goop thread lubricants SWAK, PTFE Tape, and PTFE-Free pipe thread sealants 2 Leak Detectors, Lubricants, and
More informationElastomeric Rubber Foam Sheets/Rolls. Thickness
www.heedgroup.net Elastomeric Rubber Foam Sheets/Rolls Thickness Roll Width Roll Roll Width Roll Elastomeric Rubber Foam Self Adhesive Sheets / Rolls Thickness Roll Width Roll Roll Width Roll NBR Elastomeric
More informationPERMATHERM PIPE INSULATION PRODUCTS
PERMATHERM PIPE INSULATION PRODUCTS PERMATHERM, INC. 269 Industrial Park Road Monticello, GA 31064 (706) 468-7500 www.pipe-insulation.net September 2012 This Specification Guideline in the 3-Part Format
More informationMatch your Inspection Ports to your Process Temperatures
ACCESS PLUG FLANGE, INC. The Worldwide Leader In Inspection Port Technology. O 1200 F Match your Inspection Ports to your Process Temperatures O 600 F O -32 F O -185 F Match your Inspection Ports to your
More informationInsulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS
Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage
More informationMineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths
Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable
More informationSUMITOMO RECOMMENDED PROCEDURE SRP SP-F FutureFLEX. FIELD TERMINATION KIT PROCEDURE FOR FTFLD24 900µm SUB-UNIT KIT
SUMITOMO RECOMMENDED PROCEDURE SRP SP-F04-036 FutureFLEX FIELD TERMINATION KIT PROCEDURE FOR FTFLD24 900µm SUB-UNIT KIT PARA. 1.0 2.0 3.0 4.0 CONTENTS General Safety Precautions Reference Documents Equipment
More informationShinn Thon UK Ltd 1 st Floor, 223 Dalton Road, Barrow in Furness, Cumbria. LA14 1PQ Tel: Fax:
I. Single Wall Tubing (Thin Wall) (Product No. : W-1-PT) 1.General Description: Flexible, Flame-Retardant, General Purpose, Polyolefin Tubing Product Facts 1) 2:1 & 3:1 shrink ratio; 2) Super abrasion
More informationUNITHERM ... How to order: X X A X X. Single Process Line How to order: X X X X X. Multiple Process Lines
UNITHERM.... UNITHERM 2202/2204 LIGHT-STEAM TRACE TUBING Principal of Operation Unitherm 2202/2204 pre-insulated steam trace consists of single and multiple process lines; single tracer line; moisture
More informationYORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE
YORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE Contents YORK Passive Chilled Beams 3 CB-PBE-YK / CB-PBR-YK Performance Data 5 CB-PBE-YK Dimensions 7 CB-PBR-YK Dimensions 8 Specifications 9 2 YORK Passive
More informationWEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947
WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947 WEATHER BREAKER MODEL 175 Whether you are keeping the cold out or in, nothing makes better sense for your manufacturing facility or warehouse
More informationSolar Attachment. for Flat Roofs. Roof Mounts. Pipe & Conduit Supports. Roof Repair Tape. Roofing Fasteners
Solar Attachment for Flat Roofs Roof Mounts Pipe & Conduit Supports Roof Repair Tape Roofing Fasteners 35 years working with commercial roof systems Relationships with leading roof system man u factu rers
More information1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.
SECTION 23 07 19 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationGENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS
I N SULROCK FIRE RATED METAL PANELS GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS 1. GENERAL 1.1. Summary Fire-rated panels as shown on the drawings shall be INSULROCK brand panels as supplied by Green
More informationProtect. Heatshrink and cable repair solutions
Protect Heatshrink and cable repair solutions 316 A premium selection of heatshink sleevings and cable repair products including moisture barrier kits, heatshrink repair sleeves, end caps and breakout
More informationPERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION
PermaTherm, Inc. 269 Industrial Park Road Monticello, GA 31064 (706) 468-7500 www.insulatepipe.com PERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION The specification guideline in the three-part
More informationPERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION
PermaTherm, Inc. 269 Industrial Park Road Monticello, GA 31064 (706) 468-7500 www.insulate.pipe.com/ PERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION The specification guideline in the three-part
More informationPiping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System
TCC-1 Pipe Penetration System TCC-3 Pipe Penetration System TCC-5 Pipe Penetration System 54 years of excellence... www.thybar.com 82 Table of Contents General Information 84 Specifications 85 Assembly
More informationSupport Systems for Rooftop Building Services. ecosupportproducts.com. protect the roof. protect the warranty. protect the environment.
Support Systems for Rooftop Building Services ecosupportproducts.com protect the roof. protect the warranty. protect the environment. Why EcoFoot? The design of the EcoFoot was derived from necessity.
More information12-SDMS-01 Rev.02 SPECIFICATIONS FOR
12-SDMS-01 Rev.02 SPECIFICATIONS FOR CABLE JOINTS, TERMINATIONS, AND ACCESSORIES UP TO 36 KV This specification is property of SEC and is subject to change or modification without any notice. TABLE OF
More informationHeat-Shrinkable Tubing
CPO 2:1 Shrink Ratio Thin-Wall Tubing, Non-Lined Flame-retardant, cross-linked polyolefin Continuous operating temperature: -55 C to 135 C Shrink temperature of 120 C Meets UL and CSA standards; MIL-DTL-23053/5
More informationProtection of A/C connection using a heat shrinkable jacket
Protection of A/C connection using a heat shrinkable jacket 1. Position the heat-shrinkable jacket after the cutting, deburring, inserting of standardized brass nut and flaring operations. 2. Connect the
More informationSevere-Service Union-Bonnet Needle Valves Special Alloy Materials
www.swagelok.com Severe-Service Union-Bonnet Needle Valves Special Alloy Materials N Series and HN Series Working pressures up to 10 000 psig (689 bar) Temperatures from 65 to 450 F ( 53 to 232 C) with
More informationPipe Protection Tape System
Pipe Protection Tape System PASCO All Weather Pipe Protection Tape is a pure physical barrier that is moisture proof, inert and non-conducting. Whether the need is to protect overhead piping in industrial
More informationFLEXIBLE CONDUITS AND CONNECTORS
FLEXIBLE CONDUITS AND CONNECTORS Use the best Use ANAMET! Anamet is a global company with plants in Canada, the United States and Europe. Anamet has manufactured product for the Canadian electrical industry
More informationSECTION ROOF SPECIALTIES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationØ mm. SYSTEM KAN-therm. High quality for reasonable price TECHNOLOGY OF SUCCESS ISO 9001
Ø 16 110 mm SYSTEM KAN-therm PP High quality for reasonable price TECHNOLOGY OF SUCCESS Contents 3 System KAN-therm PP The material... 94 Sanitary systems installation... 95 Pipes... 95 Thermal elongation...
More informationHeatshrink & Cable Repair Solutions
PAGE EASI-SHRINK HEATSHRINK SLEEVING ZERO-HALOGEN HEATSHRINK SLEEVING DR-25 HEATSHRINK TUBING KYNAR HIGH TEMPERATURE HEATSHRINK HEATSHRINK KITS ADHESIVE LINED HEATSHRINK SLEEVING 347-348 349-350 351 352
More informationK. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationCatalog 4200-M-2 July CAT 4200-M-2 Parflex Division - Multitube Instrument and Heat Trace Tubing Products
Catalog 4200-M-2 July 2011 CAT 4200-M-2 Parflex Division - Multitube Instrument and Heat Trace Tubing Products Extra care is taken in the preparation of this literature but Parker is not responsible for
More informationUnderground Steam Condensate Distribution Piping
University of New Hampshire University of New Hampshire Scholars' Repository Division 33 Utilities Chapter 5 Technical Construction and Renovation Standards Spring 4-16-2018 336313 Underground Steam Condensate
More informationOperable / Fixed Skylight Milgard Aluminum Window
Skylight Operable / Fixed Skylight Milgard Aluminum Window The Series Skylight has been specifically designed to provide maximum thermal efficiency by incorporating a special polyurethane barrier between
More informationPERMATHERM, INC. SPECIFICATION FOR CHILLED WATER PIPE INSULATION
PermaTherm, Inc. 269 Industrial Park Road Monticello, GA 31064 (706) 468-7500 www.insulate.pipe.com/ PERMATHERM, INC. SPECIFICATION FOR CHILLED WATER PIPE INSULATION The specification guideline in the
More informationFlame-retardant, cross-linked polyolefin. Shrink temperature of 120 C. Cat. No.*
2:1 Shrink Ratio CPO Series Thin-Wall Tubing, Non-Lined CATALOGUE NUMBER CONSTRUCTION Final Series Colour ft Order No. CPO63 + 0 + C = CPO63-0-C Available Colours 0 Black 5 Green C Clear 6 Blue 2 Red 9
More informationAdhesive Solutions for. Challenging Applications.
Adhesive Solutions for Challenging Applications www.scapana.com Scapa North America specializes in the production of high performance silicone, acrylic and rubber adhesive systems designed to meet the
More informationEffective Date: Revision #: 1. Section K: Miscellaneous. Casing Insulators/ Stainless Steel. Polyethylene Encasement.
K 1 K 2 K 3 K 4 K 5 K 6 K 7 K 8 K 9 Casing Insulators/ Stainless Steel Polyethylene Encasement Manhole Inserts Pipe Saddle Support/ Valve Vaults/ Adjustable Cylindrical Wall Seals & Line Sleeves Metal
More informationHYDRONIC PIPING
Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 Toll Free: (800) 321-4739 Phone: (952) 891-2000 Fax: (952) 891-1409 www.uponor-usa.com This specification is a manufacturer-specific proprietary
More information3M Heavy Wall Heat Shrink Tubing ITCSN
3M Heavy Wall Heat Shrink Tubing ITCSN Data Sheet September 2013 Description 3M Heavy Wall Heat Shrink Tubing ITCSN is designed to provide reliable performance for electrical splices, connections, and
More information11-SDMS-01 REV. 03 ( )
11-SDMS-01 REV. 03 (19-07-2018) SPECIFICATION FOR LOW-VOLTAGE POWER AND CONTROL CABLES Saudi Electricity Company 1. SCOPE... 3 2. CROSS REFERENCES TO OTHER SEC STANDARDS... 3 3. APPLICABLE CODES AND STANDARDS...
More informationLow Voltage Live Pot End Kits
Low Voltage Live Pot End Kits Standard heat shrink end caps are often used to seal cable ends. However where cables are live, heat shrink live pot end kits should be used. Each core is separately sealed
More informationPressure Regulators K Series
Pressure Regulators K Series 1 www.swagelok.com Pressure Regulators K Series Pressure-reducing models Back-pressure models Gas cylinder changeover model Vaporizing models 2 Pressure Regulators and Filters
More informationExpansion & Deflection Fittings. SOLUTIONS for the Construction Industry
Expansion & Deflection Fittings SOLUTIONS for the Construction Industry TTINGS FI ST D LO C AF/AF8 SERIES e st d, in M a c h e d, As d in D e s i g n e d, b le the Casted Body with NPT hub size se m Ca
More informationP R O D U C T - S P E C
P R O D U C T - S P E C Drylight TM Skylight Specification Section 08600 Skylights June 2008 This PRODUCT-SPEC is intended to provide specifiers with guidelines to properly specify Carlisle s Drylight
More informationHydraulic & Offshore Supplies. Seamless Coiled Tube YOUR GATEWAY TO GLOBAL SUPPLY
Hydraulic & Offshore Supplies Seamless ed Tube YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE T U B E P R O D U C T S large HOS Ltd has specialized
More informationPressure Regulators K Series
www.swagelok.com Pressure Regulators K Series Pressure-reducing models Back-pressure models Gas cylinder changeover model Vaporizing models Pressure Regulators, K Series 2 Swagelok K Series Pressure Regulator
More informationMaxCell Technical Manual. Design Parameters 4G Product Line
MaxCell Technical Manual Design Parameters 4G Product Line 4G Materials of Construction 4G Fabric Warp - Polyester Monofilament Diameter = 0.23 +/- 0.02 mm Denier = 520 +/- 25 Filling - Nylon 6 Monofilament
More informationRTV123. Technical Data Sheet RTV123
Technical Data Sheet RTV123 RTV123 Description RTV122, RTV123 and RTV128 adhesive sealants are one-component, ready-to-use, and cure to a tough, resilient silicone rubber on exposure to atmospheric moisture
More informationFoil-Faced Fiberglass Fabric 84215/9480 HT
Foil-Faced Fiberglass Fabric 84215/9480 HT Description Foil-Faced Fiberglass Fabric 84215/9480 HT has been specifically designed as shipboard lagging and jacketing material for use over insulation where
More informationRTV128. Technical Data Sheet
Technical Data Sheet RTV128 Description RTV122, RTV123 and RTV128 adhesive sealants are one-component, ready-to-use, and cure to a tough, resilient silicone rubber on exposure to atmospheric moisture at
More informationWire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers
Wire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers Accessories Connectors Backshells Bonding Leads Metal Braids
More informationSECTION HVAC INSULATION
PART 1 GENERAL 1.1 SUMMARY SECTION 23 07 00 HVAC INSULATION A. Section Includes: 1. Ductwork insulation. 2. Duct liner. 3. Insulation jackets. 4. Equipment insulation 5. Piping system insulation. 6. Insulation
More informationCABLE TERMINALS CABLE TERMINALS
CABLE TERMINALS CABLE TERMINALS Connection tubes 160 Isolated cable terminals 163 CABLE TERMINALS Cable terminals without isolation Connection tubes - GTY type Copper pipes with galvanic tin coating, used
More informationANTI RAM SECURITY CHAIN LINK FENCE - 4, MPH SECTION
ANTI RAM SECURITY CHAIN LINK FENCE - 4,000 LB @ 20 MPH SECTION 32 31 13.53 2015
More information1. ARI 410 Standard for chilled water, hot water and steam coils. 2. ARI 430 Central Station Air Handling Units
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More information1 of 17. PO Box Bellevue Rd, Newark, DE V F
1 of 17 Raw Material Manufactured from 4 8-foot sheets Fiber-reinforced 1-mil aluminumfaced polyisocyanurate panels 0.032 embossed aluminum Other patterns and stainless steel are available Necessary supplies
More informationFilm PEEK and Kapton. Rod / Tube PEEK, OFE Copper, and 304 Stainless Steel
UHV s UHV s Film PEEK and Kapton Features Ultrahigh vacuum compatible Cleaned for vacuum service Temperature specified for each material Specifications Vacuum Range UHV, Ultrahigh vacuum HV, High vacuum
More informationCryogenic Pipe Support Systems
Cryogenic Pipe Support Systems Overview Rilco cryogenic pipe supports are developed to support cold piping in various applications ranging from chilled water to liquefied natural gas. The qualified service
More informationArticle-No. Type. All dimensions in mm. Subject to technical changes. Other dimensions, reel lengths or colours available on request.
4.4 Installation Devices HelaTape HellermannTyton offers a wide range of PVC and rubber tapes for sealing, insulation and bundling of cable and conduits. PVC based tapes are designed for low voltage applications
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More information5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSECTION CHAIN LINK FENCES AND GATES
SECTION 32 31 13 CHAIN LINK FENCES AND GATES SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Use this section in specifying permanent chain
More information150 mm. 1/8 BSPP brass male compression fitting with locknut included
ENGLISH Datasheet Platinum Resistance PT100 Flat Tip Probe 4mm diameter x 150mm long 2 wire with 1 metre flying lead, complete with 1/8 BSP compression fitting & locknut 4mm 25mm 5.5/6mm(max) 150 mm General
More informationTubing and Pipes.
Tubing and Pipes FITOK Group FITOK GmbH (Headquarter) Sprendlinger Landstr., 9 Offenbach am Main, Germany Tel.: +49 9 900 449 Fax: +49 9 900 449 FITOK, Inc. 4 North Promenade Blvd., Suite 70, Stafford,
More informationENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead
Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat
More informationCustom-Designed Clamps. Machined Versions. Online Configurator for Custom-Designed Clamps A56.
Custom-Designed Clamps Machined Versions Custom-designed clamping systems for pipes, tubes, hoses, cables and other components according to customer`s specifications or based on developments, made of thermoplastics,
More informationShrink-Kon Thin Wall Heat Shrinkable Tubing
Shrink Ratio 2:1 Shrink-Kon Thin Wall Tubing Styles 2:1 Shrink Ratio, Non-Lined Flame retardant. Resistant to common fluids and solvents. Meets UL 224, 125 C; CSA C22.2 No. 198.1, 125 C; MIL-DTL-23053/5
More information