1 CATALOGUE

2 «Committed to bring you ever Excelling to create great innovations Since it has been launched, DIAGAST E.M. Technology shakes up the immunohaematology market by offering a competitive solution from both technical and economical points of view. QWALYS 3, our latest fully automated system, will meet the needs every biologist has to face: get fast and reliable analysis, handle budget pressure and put forward a service support for accreditation. Dynamism to reach great achievements In France, DIAGAST is a leader in the national market of immunohaematology and 90 % of bedside card tests have been performed with our ready-to-use cards. In the United States, 12 million of blood donors have been tested with our reagents by the American Red Cross thanks to a partnership with Beckman Coulter. Moreover we broke a record by selling 108 million of our tests all over the world. As well as ISO certifications, our production site has received the GMP/FDA approval and since then we can expand rapidly throughout the world. Commitment for a great expertise Relying on 30 years of expertise and a unique know-how, DIAGAST is a key company in blood transfusion sector (development, production and marketing of blood testing reagents and automated systems). Our company owns many clones in immunohaematology and is the second worldwide producer. DIAGAST keeps closely in touch with its customers through a local distribution network that enables the company to be present in more than 50 countries. Many specialised laboratories and blood transfusion centers throughout the world trust DIAGAST brand. and to excel ourselves for you every day!» 1

3 Your contacts DIAGAST 251, avenue Eugène Avinée - Parc Eurasanté - BP LOOS CEDEX - FRANCE Tel. : +33 (0) Fax : +33 (0) Order department Florence Belet - Tel. : +33 (0) orders@diagast.com International hotline and after-sales services Tel. : +33 (0) hotline@diagast.com Training Center Tel. : +33 (0) trainingcentre@diagast.com Website : Please visit our website to have information about our worldwide favorite business partners or to have access to our technical inserts 2

4 Your immunohaematology the way you need it E.M. Technology QWALYS 3: High performance blood grouping automated system 4 FREELYS Mini Lab, an ingeniously compact all-in-one workstation 6 Ready-to-use reagents on QWALYS and FREELYS Nano 8 Olymp range QWALYS 3 FREELYS Mini Lab Ready-to-use reagents for PK 7200/PK Internal quality control 14 O.E.M. / F.F.M.U Concentrated bulk 15 Ready to use bulk 16 Manual techniques ABO-D typing 18 Anti-D 19 Rh-Kell Phenotyping 20 Rare sera 21 Enzymes - Buffer - Antiglobulins 21 Material and Consumables 22 Safety Card 23 Automated techniques Micro range: ready-to-use microplates 24 Immuno-serology 24 Syphilis, Tetanus 3

5 E.M. Technology High performance Blood grouping automated system With its very high throughput and its loading capacity surpassing the other machines available in the market, QWALYS 3 is the reference machine for all blood banks, blood transfusion centres and hospitals having a blood grouping testing activity from to tests per year. QWALYS 3 is based on E.M. Technology (Erythrocytes Magnetized Technology) an innovative nanotechnology developed by DIAGAST, using the principle of magnetization of the red blood cells. High throughput and autonomy maximum loading capacity from 160 to 256 samples Very high throughput : Up to 105 Grouping or 110 Antibody Screening or 250 Antibody Screening donors per hour. Ease of use With only one intuitive user screen, QWALYS 3 is friendly and versatile. Only 10 minutes of training is enough to launch a serie of tests in complete autonomy. On screen real-time display of your workflow (reagent consumption, sample status). Cost efficiency Compared to the other automated techniques available E.M. Technology guarantees best cost efficiency with equivalent or better biological results. Personalized customer services Specialized engineers all around the world and a dedicated hotline for better expertise Service pack with remote access tools for a faster service Skilled sales and marketing team to support you for the management of your immunohematology lab. QWALYS 3 Designation Reference Composition QWALYS Autonomy : 32 microplates, 6 diluents, 10 reagents L : 150 cm ; l : 78 cm ; H : 98 cm / 4 needles QWALYS Autonomy : 32 microplates, 6 diluents, 10 reagents L : 150 cm ; l : 78 cm ; H : 98 cm / 8 needles 4

6 5

7 E.M. Technology FREELYS Mini lab, & an ingeniously compact all-in-one workstation DIAGAST FREELYS Mini Lab provides its full efficiency to your manual immuhaematology techniques by offering both miniaturization and ergonomics. Thanks to a work station (FREELYS Nano) and a reader (FREELYS Reader & Software) you will enjoy standardization, safety, traceability and cost saving. FREELYS Nano Forget your bulky equipments (centrifuge, incubator) and discover FREELYS Nano that ingeniously integrates the whole associated material: a shaker, an incubator and magnetic plates. FREELYS Nano is the miniaturized workstation that will bring you a standardization of the protocols never seen before. FREELYS Reader FREELYS Reader and Software is designed for the reading, interpretation, validation and database storage of your immunohaematology lab bench. Its high definition video camera ensures a secured interpretation of your results. With the FREELYS Software you can now consult, modify, validate and record electronically your results with complete traceability of patients and reagents. Its search engine allows a fast and easy consultation of your whole archive with results, patient database and picture of the reactions. FREELYS Nano and FREELYS Reader Designation Reference Composition FREELYS Nano (2 shakers) FREELYS Nano (1 shaker) A workstation, 1 or 2 automatic shakers (Nano Shake), 1 or 2 magnetic plates (Nano Mag), 1 Nano Mag support, 2 meter-long power cable, 1 Allen key, 1 operating guide. FREELYS Reader The reader, power cable, USB cable, barcode reader, user software (computer not included) 6

8 E.M. Technology Principle Grouping and phenotyping Patient red blood cells Hemascreen Antibody screening Serum or plasma Magnetic Particules (Magnelys) Bromelin Predispensed monoclonal IgM antisera Magnet AHG (Anti-Human-IgG) Screen diluent Nanolys Magnet 1% Dilution of RBC in Bromelin and MagneLys dispensed in Microplate Magnetized red blood cell Predispensed monoclonal IgM antisera Shaking: Rehydratation of antisera and contact with RBC antigens 10 min incubation at room temperature 20 min incubation at 37 C : RBC antibodies fixed on Hemascreen Irrelevant antibody RBC antibody Hemascreen (premagnetized RBC) Nanolys AHG Nanolys AHG Magnet Magnetization: Magnetized RBC attracted by magnetic field to the bottom of the well Shaking 4+ Magnetic shaking: Magnetic field + shaking the Hemascreen cross the NanoLys (high density barrier): The magnetic field as no influence on the irrelevant antibodies as they are not magnetized. The irrelevant antibodies remain blocked at the surface of the nanolys: no washing step 4+ In case of positive reaction: Agglutination Neg RBC antibodies fixed on Hemascreen In case of positive reaction: Layer Reaction with AHG Neg In case of negative reaction: No Agglutination Interpretation No RBC antibodies no reaction with AHG: the Hemascreen creates a dot In case of negative reaction: Clear dot Interpretation Neg Mixed field agglutination Neg

9 E.M. Technology range Grouping and phenotyping Designation Reference Quantity Configuration Ready-to-use reagents on microplates DuoLys tests 12 microplates of 8 tests, Magnelys 40 ml ABD-Lys tests 10 microplates of 16 tests, Magnelys 40 ml Groupa 2 Lys tests 12 microplates of 8 tests, Magnelys 40 ml Groupa DVI Lys tests 12 microplates of 8 tests, Magnelys 40 ml Groupa CDE Lys tests 12 microplates of 8 tests, Magnelys 40 ml PhenoLys tests 12 microplates of 16 tests, Magnelys 40 ml Pheno 1,2 Lys tests 12 microplates of 8 tests, Magnelys 40 ml Groupa A1 Lys tests 12 microplates of 8 tests A B AB D C c E e K Ctl o o A B D Ctl o o A B D Ctl o o A B AB D1 D2 Ctl o o o o o o A B AB D1 D3 Ctl o o o o o o (DVI -) (DVI +) A B AB D CDE Ctl o o o o o o C c E e K Ctl C c E e K Ctl C1 c1 E1 e1 K1 Ctl C2 c2 E2 e2 K2 Ctl A A1 B AB D1 D2 Ctl o o o o o Reverse typing Red Blood Cells * HEMALYS A1, B * x 5 ml Magnetized A1 and B (2 x 5 ml) HEMALYS A1, A2, B, O * x 5 ml Magnetized red blood cells A1, A2, B and O (4 x 5 ml) Diluents BROMELINE x 100 ml x 100 ml MagneLys x 40 ml Dilution plates D-Plates tests 10 plates for the red blood cells dilution on QWALYS Internal Quality Control HEMA CQI* x 4 ml Antibody Screening (A.B.S.) ScreenLys tests For IgG screening 6 AHG coated plates, NanoLys (7 x 8 ml), Screen Diluent (50 ml) HemaScreen* tests Panel of 3 magnetized red blood cells (3 x 4,5 ml) Internal Quality Control SERA CQI x 5 ml 8 *on subscription

10 E.M. Technology range Direct Coombs Designation Reference Quantity/configuration DC-Lys kit tests This kit includes the references below DC-Lys coated plates with antiglobulins (IgG, C3D) MagLys (magnetizing solution) NanoLys DiluentLys ScreenDiluent Mag-Plates plates of 48 tests for dilution Tube 11mm tubes IgG C3D Ctl IgG C3D Ctl IgG C3D Ctl IgG C3D Ctl Identification ScreenLys tests 6 AHG coated plates, NanoLys (7 x 8 ml), Screen Diluent (50 ml) Hema-Ident ext * tests Panel of 11 ready-to-magnetize red blood cells MagLys (magnetizing solution) tests Crossmatch CrossLys kit tests This kit includes the references below CrossLys plates of 96 tests coated with antiglobulin MagLys (magnetizing solution) NanoLys DiluentLys ScreenDiluent Mag-Plates plates of 48 tests for dilution Antibody Screening Donors ScreenLys tests 6 coated plates, NanoLys (7 x 8 ml), Screen Diluent (50 ml) HemaScreen Pool * tests Pool of magnetized red blood cells (4,5 ml) Disposables CleanLys 10X liter Decontamination solution for QWALYS Adhesiplates units Microplate adhesive sealing sheet Barcode Labels (for barcode duplicator) units Barcode printer (for barcode duplicator) unit Barcode scanner (for barcode duplicator) unit 9

11 Automated technique: Olymp range PK st determination : ABO-D typing Designation Reference Quantity Clones ANTI-A (ABO1) OLYMP GROUP I PK x 30 ml 2521B G2 Anti-B (ABO2) OLYMP GROUP I PK x 30 ml 9621A8 Anti-A,B (ABO3) OLYMP GROUP I PK x 30 ml 2521B G E D9 Anti-D (RH1) TOTEM OLYMP PK x 30 ml P3x61 + P3x21223B10 + P3x290 Anti-D (RH1) I OLYMP PK x 30 ml P3x61 + P3x35 OLYMP CONTROL PK x 30 ml Negative control 2 nd determination : ABO-D typing Anti-A (ABO1) OLYMP GROUP II PK x 30 ml 9113D10 Anti-B (ABO2) OLYMP GROUP II PK x 30 ml 164B5G D9 Anti-A,B (ABO3) OLYMP GROUP II PK x 30 ml 152D D10 Anti-D (RH1) II OLYMP PK x 30 ml HM10 OLYMP CONTROL PK x 30 ml Negative control Ready-to-use red blood cells HEMAOLYMP 1 A1, A2, B, O * x 30 ml HEMAOLYMP 2 A1, A2, B, O * x 30 ml HEMAOLYMP A1, B * x 30 ml With an Olymp range vial of 30 ml you can perform 1200 tests 10 *On subscription

12 Automated technique: Olymp range PK st determination : Rh-Kell phenotyping Designation Reference Quantity Clones Anti-C (RH2) OLYMP PHENO PK x 30 ml P3x25513G8 + MS24 Anti-E (RH3) OLYMP PHENO PK x 30 ml 906 Anti-c (RH4) OLYMP PHENO PK x 30 ml MS33 Anti-e (RH5) OLYMP PHENO PK x 30 ml P3GD512 + MS63 Anti-K (KEL1) OLYMP PHENO PK x 30 ml MS56 OLYMP CONTROL PK x 30 ml Negative control 2 nd determination : Rh-Kell phenotyping Anti-C (RH2) OLYMP SCREEN PK x 30 ml DGC02 Anti-E (RH3) OLYMP SCREEN PK x 30 ml P3x234 + MS258 Anti-c (RH4) OLYMP SCREEN PK x 30 ml 951 Anti-e (RH5) OLYMP SCREEN PK x 30 ml HS128 + MS21 Anti-K (KEL1) OLYMP SCREEN PK x 30 ml 601 OLYMP CONTROL PK x 30 ml Negative control Ready-to-use Bromelin BROMOLYMP PK x 1 liter With an Olymp range vial of 30 ml you can perform 1200 tests 11

13 Automated technique: Olymp range PK st determination : ABO-D typing Designation Reference Quantity Clones ANTI-A (ABO1) OLYMP GROUP I PK x 20 ml 2521B G2 ANTI-B (ABO2) OLYMP GROUP I PK x 20 ml 9621A8 ANTI-A,B (ABO3) OLYMP GROUP I PK x 20 ml 2521B G E D9 ANTI-D (RH1) TOTEM OLYMP PK x 20 ml P3x61+P3x21223B10 +P3x290+P3x35 ANTI-D (RH1) I OLYMP PK x 20 ml P3x61 OLYMP CONTROL PK x 20 ml Negative control 2 nd determination : ABO-D typing Anti-A (ABO1) OLYMP GROUP II PK x 20 ml 9113D10 Anti-B (ABO2) OLYMP GROUP II PK x 20 ml 164B5G D9 Anti-A,B (ABO3) OLYMP GROUP II PK x 20 ml 152D D10 ANTI-D (RH1) II OLYMP PK x 20 ml HM10 OLYMP CONTROL PK x 20 ml Negative control Ready-to-use red blood cells HEMAOLYMP 1 A1, A2, B, O PK7300 * x 20 ml HEMAOLYMP 2 A1, A2, B, O PK7300 * x 20 ml With an Olymp range vial of 20 ml you can perform 800 tests 12 *On subscription

14 Automated technique: Olymp range PK st determination : Rh-Kell phenotyping Designation Reference Quantity Clones Anti-C (RH2) OLYMP PHENO PK x 20 ml P3x25513G8 + MS24 Anti-E (RH3) OLYMP PHENO PK x 20 ml 906 Anti-c (RH4) OLYMP PHENO PK x 20 ml MS33 Anti-e (RH5) OLYMP PHENO PK x 20 ml P3GD512 + MS63 Anti-K (KEL1) OLYMP PHENO PK x 20 ml MS56 OLYMP CONTROL PK x 20 ml Negative control 2 nd determination : Rh-Kell phenotyping Anti-C (RH2) OLYMP SCREEN PK x 20 ml DGC02 Anti-E (RH3) OLYMP SCREEN PK x 20 ml P3x234 + MS258 Anti-c (RH4) OLYMP SCREEN PK x 20 ml 951 Anti-e (RH5) OLYMP SCREEN PK x 20 ml HS128 + MS21 Anti-K (KEL1) OLYMP SCREEN PK x 20 ml 601 OLYMP CONTROL PK x 20 ml Negative control Ready-to-use Bromelin BROMOLYMP PK x 900 ml With an Olymp range vial of 20 ml you can perform 800 tests 13

15 Internal quality control ABO-D typing and Rhesus-Kell Designation Reference Quantity HEMA CQI * (A, B, AB, O) x 4 ml Designation Group Phenotyping Antibodies HEMA CQI 1 AB D- C- E- c+ e+ RH-1, -2, -3, 4, 5 K - KEL - 1 HEMA CQI 2 B D+ C+ E- c- e+ RH 1, 2, -3, -4, 5 K - KEL - 1 Anti-A (ABO1) HEMA CQI 3 0 D+ C+ E+ c+ e+ RH 1, 2, 3, 4, 5 K + KEL 1 Anti-A (ABO1) Anti-B (ABO2) HEMA CQI 4 A D+ C- E+ c+ e- RH 1, -2, 3, 4, -5 K - KEL - 1 Anti-B (ABO2) Antibody Screening SERA CQI x 5 ml Designation Antibodies Results SERA CQI 1 Anti-D (RH1) 4+ SERA CQI 2 Anti-Fya (FY1) 1+ SERA CQI 3-14 *on subscription

16 O.E.M. / F.F.M.U. - Concentrated Bulk ABO-D typing Designation Reference Type ANTI-A CONCENTRATE BULK (9113D10) IgM ANTI-B CONCENTRATE BULK (9621A8) IgM ANTI-A,B CONCENTRATE BULK (152D D10) IgM ANTI-D IGG CONCENTRATE BULK (P3x290) IgG ANTI-D IGM CONCENTRATE BULK (P3x61) IgM ANTI-D IGM CONCENTRATE BULK (P3X21223B10) IgM ANTI-D IGG CONCENTRATE BULK (P3x35) IgG ANTI-D IGM CONCENTRATE BULK (HM10) IgM ANTI-D IGG CONCENTRATE BULK (HM16) IgG Rh-Kell Phenotyping ANTI-C (RH2) CONCENTRATE BULK (P3x25513G8) IgM ANTI-E (RH3) CONCENTRATE BULK (906) IgM ANTI-c (RH4) CONCENTRATE BULK (951) IgM ANTI-e (RH5) CONCENTRATE BULK (P3GD512) IgM ANTI-K (KEL1) CONCENTRATE BULK (601) IgG Diluent DILUTION MEDIUM X

17 O.E.M. / F.F.M.U. - Ready-to-use bulk ABO-D typing Designation Reference Type Anti-A DIAGAST BULK (9113D10) IgM Anti-B DIAGAST BULK (9621A8) IgM Anti-AB DIAGAST BULK (152D D10) IgM Anti-H DIAGAST BULK (10934C11) IgM Anti-D IgM DIAGAST BULK (P3X61) IgM Anti-D IgM DIAGAST BULK (HM10) IgM Anti-D IgG DIAGAST BULK (P3X290) IgG Anti-D IgG DIAGAST BULK (HM16) IgG Anti-D Totem DIAGAST BULK (P3X61+P3X21223B10+P3X290+P3X35) IgM + 2 IgG NEGATIVE CONTROL DIAGAST BULK Rh-Kell Phenotyping Anti-C DIAGAST BULK (P3X25513G8) IgM Anti-C DIAGAST BULK (P3X25513G8+MS24) IgM Anti-E DIAGAST BULK (906) IgM Anti-c DIAGAST BULK (951) IgM Anti-e DIAGAST BULK (P3GD512+MS63) IgG Anti-Kell DIAGAST BULK (601) IgG Anti-Kell DIAGAST BULK (MS56) IgM Anti-CDE DIAGAST BULK (P3X25513G8+P3X61+P3X234) IgM Diluent DILUTION MEDIUM X

18 O.E.M. / F.F.M.U. - Ready-to-use bulk Rare Sera Designation Reference Type Anti-Fya (FY1) DIAGAST BULK (DG-FYA-02) IgG Anti-M (MNS1) DIAGAST BULK (2514E6) IgM Anti-N (MNS2) DIAGAST BULK (1422C7) IgM Anti-Jka (JK1) DIAGAST BULK (P3HT7) IgM Anti-Jkb (JK2) DIAGAST BULK (P3.143) IgM Anti-Lea (LE1) DIAGAST BULK (13643B9) IgM Anti-Leb (LE2) DIAGAST BULK (GX336) IgM Anti-S (MNS3) DIAGAST BULK (P3S13JS123) IgG Anti-s (MNS4) DIAGAST BULK (P3YAN3) IgG Anti-P1 DIAGAST BULK (650) IgM Antiglobulins Designation Reference Clones Maestria (polyspecific IgG + C3d) D10 Antiglobulin anti-c3d monoclonal D10 Maestria IgG (mono specifique IgG) Bromelin Bromelin 100 ml Other Reagents A and B Substances

19 ABO-D typing in manual technique Reagents for ABO-D typing Designation Reference Quantity Clones ANTI-A (ABO1) x 10 ml (5x200 tests) 9113D10 ANTI-B (ABO2) x 10 ml (5x200 tests) 9621A8 ANTI-A,B (ABO3) x 10 ml (5x200 tests) 152D D10 ANTI-D (RH1) IgM I x 10 ml (5x200 tests) P3x61 ANTI-D (RH1) IgM II x 10 ml (5x200 tests) HM10 ANTI-D (RH1) TOTEM x 10 ml (5x200 tests) P3x61+P3x21223B10+P3x290+P3x35 ANTI-D (RH1) IgG x 10 ml (5x200 tests) HM16 NEG CONTROL x 10 ml (5x200 tests) Negative control ANTI-A (ABO1) x 10 ml (100x200 tests) 9113D10 ANTI-B (ABO2) x 10 ml (100x200 tests) 9621A8 ANTI-A,B (ABO3) x 10 ml (100x200 tests) 152D D10 ANTI-D (RH1) IgM I x 10 ml (100x200 tests) P3x61 ANTI-D (RH1) TOTEM x 10 ml (100x200 tests) P3x61+P3x21223B10+P3x290+P3x35 NEG CONTROL x 10 ml (100x200 tests) Negative control Kit for one determination GROUPAKIT x 10 ml (200 tests) see clones above Includes ANTI-A (ABO1), ANTI-B (ABO2), ANTI-A,B (ABO3), ANTI-D (RH1) IgM I, NEG CONTROL Ready-to-use red bloos cells (5 %)* HEMATEST A1, B * x 5 ml (2x100 tests) HEMATEST A1, A2, B, O * x 5 ml (4x100 tests) 18 *On subscription

20 Anti-D in manual technique The most complete Anti-D Designation Reference Quantity Clones ANTI-D (RH1) TOTEM x 10 ml (5x200 tests) P3x61 + P3x21223B10 + P3x290 + P3x35 2 clones IgM, 2 clones IgG Weak D detection in tube and slide techniques at room temperature Weak D detection in IAT (Indirect Antiglobulin Test) Detection of the most frequent partial D (DVI) at room temperature Weak D detection (D u ) ANTI-D (RH1) IgG x 10 ml (5x200 tests) HM16 I.A.T (Indirect Antiglobulin Test) 2 complementary reagents ANTI-D (RH1) IgM I x 10 ml (5x200 tests) P3x61 ANTI-D (RH1) IgM II x 10 ml (5x200 tests) HM10 For the detection and indentification of partial D Rhesus D-SCREEN x 2 ml For research use Kit of 9 monoclonal anti-d for identification of partial D: 5 IgG and 4 IgM (Frozen) N Clone Type II IIIa IIIb IIIc Partial D IVa IVb Va VI VII DFR DBT RoHar HMi 1 HM10 IgM HM16 IgG P3x61 IgM P3x35 IgG P3x21211F1 IgM P3x21223B10 IgM P3x241 IgG P3x249 IgG P3x290 IgG I +I +I +I 19

21 Rh-kell phenotyping in manual technique Rh-Kell phenotyping Designation Reference Quantity Clones ANTI-C (RH2) x 5 ml (4x100 tests) P3x25513G8 + MS24 ANTI-E (RH3) x 5 ml (4x100 tests) 906 ANTI-c (RH4) x 5 ml (4x100 tests) 951 ANTI-e (RH5) x 5 ml (4x100 tests) P3GD512 + MS63 ANTI-K (KEL1) x 5 ml (4x100 tests) MS56 ANTI-DCE (RH1,2,3) x 5 ml (5x100 tests) P3x25513G8 + P3x61 + P3x234 NEG CONTROL x 10 ml (5x200 tests) Negative control Kit for one determination PHENOKIT x 5 ml (100 tests) See clones above Includes ANTI-C (RH2), ANTI-E (RH3), ANTI-c (RH4), ANTI-e (RH5), ANTI-K (KEL1) 20

22 Rare sera in manual technique Monoclonal and polyclonal reagents Designation Reference Quantity Clones ANTI-Cw (RH8) x 3 ml MS110 ANTI-Fya (FY1) x 3 ml DG-FYA-02 ANTI-Jka (JK1) x 3 ml P3HT7 ANTI-Jkb (JK2) x 3 ml P3.143 ANTI-M (MNS1) x 3 ml 2514E6 ANTI-N (MNS2) x 3 ml 1422C7 ANTI-S (MNS3) x 3 ml P3S13JS123 ANTI-s (MNS4) x 3 ml P3YAN3 ANTI-Lea (LE1) x 3 ml 13643B9 ANTI-Leb (LE2) x 3 ml GX336 ANTI-P x 3 ml 650 NEG CONTROL x 10 ml Negative control (for monoclonal reagents) ANTI-Fyb (FY2) x 3 ml Polyclonal POLY CONTROL x 10 ml Negative control (for polyclonal reagents) Enzymes - Buffer - Antiglobulins BROMELINE x 100 ml x 100 ml PALERM ml Ready-to-use papain LISS litre Low Ionic Strength Solution (L.I.S.S.) AGH MAESTRIA C3D x 5 ml 12011D10 AGH MAESTRIA IGG x 10 ml AGH MAESTRIA IGG+C3D x 10 ml D10 21

23 Consumable Disposable white plates for grouping and reverse typing Designation Reference Quantity NACRYL BOX NACRYL 5 (5 x 5 wells) NACRYL 6 (5 x 6 wells) NACRYL 7 (5 x 7 wells) NACRYL 9 (5 x 9 wells) NACRYL 10 (5 x 10 wells) NACRYL 12 (5 x 12 wells) BIOPALINE (2 x 5 wells) (Size : 68 x 153 mm) Associated material SECURITUBES

24 Safety card Pack size Designation Reference quantity SAFETY CARD AB cards SAFETY PACK kits 1 Disposable lancet + 1 securitube + 1 vial of isotonic saline solution + 4 strirrer-pipettes SAFETY TEST ABO kits 1 SAFETY CARD AB + 1 SAFETY PACK SAFETY CARD AB Patient (Nom & Prénom) : Culot Globulaire N : Nom de jeune fille : Date de naissance : Patient Culot 1 Déposer 1 de sang du patient dans et 1 de sang du culot dans. 2 Déposer 1 d eau physiologique NaCl 0,9% dans les 4 alvéoles. 3 Prélever et déposer le sang en une seule fois dans chaque alvéole de la même colonne en changeant de Anti-A Anti-A spatule à chaque transfert puis mélanger en évitant toute contamination. 4 Lire les réactions après 1 minute, si une réaction est négative poursuivre obligatoirement la lecture à 3 minutes, puis interpréter. Anti-B Anti-B «Pour un même réactif (même couleur), toute réaction positive avec Patient Culot le culot à transfuser et négative avec Noter avec 1 X la réaction positive le patient interdit la transfusion.» sinon noter 0 En cas de doute, contacter le médecin encadrant la transfusion. Conclusion : transfuser OUI - NON / Réalisé au lit du patient par (Nom) : Date : Heure : Signature : Rules of compatibility O A B AB Exemples of results Reactions result in agreement. According to the ABO compatibility rules, Reactions result in disagreement. According to the ABO compatibility rules, Reactions result in disagreement. According to the ABO compatibility rules : transfusion is possible transfusion is possible transfusion is not possible Compatible Compatible Incompatible Customization Bedside tests are available in your language. Feel free to contact us for further information. 23

25 Automated technique: Micro range Ready-to-use microplates Designation Reference Quantity Composition DuoMicro x 8 tests GroupaMicro x 12 tests PhenoMicro x 12 tests Groupa 2D Micro x 8 tests A B AB D C c E e K Ctl o o Ctl D A B AB o o o Ctl D C E c e K o A B AB D1 D2 Ctl o o o o o o Réactifs Anti-A Anti-B Anti-A,B Anti-D1 Anti-D2 Anti-E Anti-c Anti-e Anti-K Anti-C Clones 9113D10 + P3GD512 + P325513G8 9113D A8 P3x61 HM MS33 MS56 152D12 MS63 + MS24 Origin Murine Human Ready-to-use red blood cells (1%) * HEMAMICRO A1, B* x 5 ml HEMAMICRO 1 A1, A2, B, O * x 5 ml HEMAMICRO 2 A1, A2, B, O * x 5 ml Ready-to-use bromelin BROMELINE x 100 ml x 100 ml Syphilis - Tetanus Syphilis : manual VDRL Cardiolipidic reagents VDRL Designation Reference Quantity SYPAL CB ml (150 tests) To be used on disposable cards Control Sera SEROPOS ml Ready-to-use positive control serum standardized for use with VDRL technique against WHO standards 24 Tetanus Hyperimmune antitetanus plasma ELISAT x 96 tests ELISA technique (with a standard range). Identification of hyperimmune antitetanus plasma. Usable with automated sampler. *On subscription

26 T he blood matching company 251, avenue Eugène Avinée - Parc Eurasanté LOOS - FRANCE V EN

SUMMARY E.M. TECHNOLOGY M-TRAP TECHNOLOGY PK RANGE MANUAL RANGE QUALITY CONTROLS BEDSIDE CARD O.E.M. RANGE TRAINING CENTRE P P. 4-5 P.

SUMMARY E.M. TECHNOLOGY M-TRAP TECHNOLOGY PK RANGE MANUAL RANGE QUALITY CONTROLS BEDSIDE CARD O.E.M. RANGE TRAINING CENTRE P P. 4-5 P. CATALOGUE SUMMARY P. 4-5 M-TRAP TECHNOLOGY P. 6-17 E.M. TECHNOLOGY P. 18-21 PK RANGE P. 22-29 MANUAL RANGE P. 30-31 QUALITY CONTROLS P. 32-33 BEDSIDE CARD P. 34-38 O.E.M. RANGE P. 39-40 TRAINING CENTRE

More information

For order enquiries. Telephone Fax For technical information

For order enquiries. Telephone Fax For technical information Sanquin is responsible for safe and efficient blood supply in the Netherlands on a not-for-profit basis. Sanquin also develops and produces pharmaceutical products, conducts high-quality scientific research,

More information

Original Equipment Manufacturing. Intermediate and OEM Products for Immunohaematology

Original Equipment Manufacturing. Intermediate and OEM Products for Immunohaematology Original Equipment Manufacturing Intermediate and OEM Products for Immunohaematology A long history as an OEM manufacturer For over 30 years, Quotient has developed, manufactured and marketed high quality

More information

Sanquin Blood Grouping Reagents

Sanquin Blood Grouping Reagents Sanquin Blood Grouping Reagents Blood grouping reagents are essential tools for diagnostic laboratories specialised in serology. The broad range of reagents developed by Sanquin Reagents is used in several

More information

PRETRANSFUSION OR COMPATIBILITY TESTING

PRETRANSFUSION OR COMPATIBILITY TESTING 13 PRETRANSFUSION OR COMPATIBILITY TESTING 13.1 INTRODUCTION Pretransfusion compatibility testing serves to select a compatible unit of blood for the recipient which when transfused does not cause any

More information

BIOSCOT Blood Typing Monoclonal Reagents

BIOSCOT Blood Typing Monoclonal Reagents BIOSCOT Blood Typing Monoclonal Reagents Merck Millipore, your partner for monoclonal blood typing diagnostics For over 25 years Merck Millipore has been leading the development of monoclonal antibodies

More information

Safety Data Sheets for Blood Bank Products

Safety Data Sheets for Blood Bank Products Safety Data Sheets for Blood Bank Products Dear Valued Customer: Ortho Clinical Diagnostics (OCD) provides Safety Data Sheets (SDS) for any OCD products that contain hazardous materials at or above regulated

More information

IMMUNOHAEMATOLOGY WHOLE BLOOD KIT FOR INTERNAL QUALITY CONTROL

IMMUNOHAEMATOLOGY WHOLE BLOOD KIT FOR INTERNAL QUALITY CONTROL PRODUCT CATALOGUE IMMUNOHAEMATOLOGY WHOLE BLOOD KIT FOR INTERNAL QUALITY CONTROL 44100 Rea IQC Total Blood Kit 25 30% 4 x 6 ml Immunohaematology control kit for all methods Also avoilable in 4x4 ml presentation

More information

RCPAQAP TRANSFUSION GENERAL TRANSFUSION PROGRAM METHOD CLASSIFICATION MASTERLIST

RCPAQAP TRANSFUSION GENERAL TRANSFUSION PROGRAM METHOD CLASSIFICATION MASTERLIST A.B.N. 32 003 520 072 RCPAQAP TRANSFUSION GENERAL TRANSFUSION PROGRAM METHOD CLASSIFICATION MASTERLIST 2013 Before 1 July 2013 After 1 July 2013 RCPAQAP Transfusion RCPAQAP Centre Of Excellence PO Box

More information

ScanGel Monoclonal ABO/RH Cards Cards

ScanGel Monoclonal ABO/RH Cards Cards ScanGel Monoclonal ABO/RH 86496 48 Cards 86426 288 Cards GELS FORMULATED WITH MONOCLONAL REAGENTS OF MURINE OR HUMAN ORIGIN ABO forward test. RH1 Ag determination IVD All the products manufactured and

More information

Val Tunnard Sheffield RCI. Red Cell Immunohaematology

Val Tunnard Sheffield RCI. Red Cell Immunohaematology Val Tunnard Sheffield RCI Produced by the immune system Created in response to a foreign antigen Protein (Immunoglobulins) in serum/plasma Red cell antibodies are either: IgG, 2 binding site IgM, 10 binding

More information

Red Cell Immunohaematology. Mark Dwight Specialist Biomedical Scientist RCI Filton

Red Cell Immunohaematology. Mark Dwight Specialist Biomedical Scientist RCI Filton Red Cell Immunohaematology Mark Dwight Specialist Biomedical Scientist RCI Filton The RCI Laboratories Red Cell Immunohaematology Reference laboratories supporting hospital blood banks in England. RCI

More information

Requirements of IBTO (AABB) Standards d for a Blood Transfusion Request 1.Positive identification of the recipient and the recipient blood samples.

Requirements of IBTO (AABB) Standards d for a Blood Transfusion Request 1.Positive identification of the recipient and the recipient blood samples. Detection and Identification of alloantibodies to Red Cell Antigens Antibody Screen Test Iranian Blood Transfusion Organization Mostafa Moghaddam MS, CLS ( ASCP ) BB Head of Immunohematology Reference

More information

NHS Blood and Transplant Reagents. Meeting your serology needs

NHS Blood and Transplant Reagents. Meeting your serology needs NHS Blood and Transplant Reagents Meeting your serology needs NHSBT Reagents meet your serology needs by manufacturing a portfolio of transfusion related diagnostic reagents, supporting our commercial

More information

Skills: 20 points. Objectives:

Skills: 20 points. Objectives: Exercise 5 Type and Screen Skills: 20 points Objectives: 1. List three situations in which screening for unexpected antibodies should be performed. 2. List two patient populations who are candidates for

More information

Blood Reagents and Diagnostic Kits. Quality reagents and medical laboratory equipment delivered worldwide

Blood Reagents and Diagnostic Kits. Quality reagents and medical laboratory equipment delivered worldwide Blood Reagents and Diagnostic Kits Quality reagents and medical laboratory equipment delivered worldwide September 2014 Lorne Laboratories provides high quality blood-grouping reagents, diagnostic kits

More information

Mechanisms of extravascular destruction of red cells coated with IgG1 or IgG3 (± C3b).

Mechanisms of extravascular destruction of red cells coated with IgG1 or IgG3 (± C3b). Introduction - Antibodies involved in transfusion reactions are of two types, namely the complete and the incomplete. - whereas the complete antibodies agglutinate red cells in saline medium, the incomplete

More information

CLINICAL SIGNIFICANCE:

CLINICAL SIGNIFICANCE: Subject Crossmatch Procedure Gel Method Index Number Lab-8769 Section Laboratory Subsection Regionals/Affiliates Category Departmental Contact Rachel Blum Last Revised 9/7/2017 References Required document

More information

Serology & Immunology

Serology & Immunology Serology & Immunology PRODUCT LIST 2018 2 INDEX Cellbind gel cards 3 Reagents in Cellbind gel cards ABO 3 Rhesus 4 Rhesus second line 4 Rare antigens 4 Controls 5 Reagent red cells in Cellbind gel cards

More information

Blood Typing Monoclonal Antibodies. Blood typing intermediates for further manufacturing use

Blood Typing Monoclonal Antibodies. Blood typing intermediates for further manufacturing use Blood Typing Monoclonal Antibodies Blood typing intermediates for further manufacturing use Merck Millipore, your partner for monoclonal blood typing antibodies For more than 25 years we have been leading

More information

Applicable To Employees of the Gundersen Palmer Lutheran Hospitals and Clinics laboratories.

Applicable To Employees of the Gundersen Palmer Lutheran Hospitals and Clinics laboratories. Subject ABO Forward Grouping - D Antigen Typing - Palmer Index Number Lab-8791 Section Laboratory Subsection Regional/Affiliates Category Departmental Contact Betty Tilleraas Last Revised 10/31/2017 References

More information

Use and Abuse of Reagents and Techniques. Joann Moulds PhD, MT(ASCP)SBB Director, Scientific Support Services LifeShare Blood Centers Shreveport, LA.

Use and Abuse of Reagents and Techniques. Joann Moulds PhD, MT(ASCP)SBB Director, Scientific Support Services LifeShare Blood Centers Shreveport, LA. Use and Abuse of Reagents and Techniques Joann Moulds PhD, MT(ASCP)SBB Director, Scientific Support Services LifeShare Blood Centers Shreveport, LA. Antibody Screening & Identification Blood Grouping Reference

More information

PRODUCT CATALOG. Immunohematology.

PRODUCT CATALOG. Immunohematology. PRODUCT CATALOG Immunohematology www.biognost.com Complete dedication to science Fulfilling our ambition - first to detect, develop, and offer solutions Our everyday business is shaped by clear missions,

More information

Observations for UK NEQAS (BTLP) data. Jenny White Deputy Scheme Manager (BTLP)

Observations for UK NEQAS (BTLP) data. Jenny White Deputy Scheme Manager (BTLP) Observations for UK NEQAS (BTLP) data Jenny White Deputy Scheme Manager (BTLP) UK NEQAS Q data 2016 Technology used for routine G+S Inherent differences in IAT technology Solid phase Easy to automate Adherence

More information

Compatibility Testing. Compatibility testing is performed to determine if a particular unit of blood can be transfused safely into a certain patient.

Compatibility Testing. Compatibility testing is performed to determine if a particular unit of blood can be transfused safely into a certain patient. Compatibility Testing Compatibility testing is performed to determine if a particular unit of blood can be transfused safely into a certain patient. This includes ABO-Rh blood typing, antibody screening

More information

BLOOD TYPING REAGENTS. Product Profile

BLOOD TYPING REAGENTS. Product Profile BLOOD TYPING REAGENTS Product Profile 2 BLOOD TYPING REAGENTS Its all about Human Blood Human blood is classified based on presence or absence of inherited antigens on the surface of red blood cells (RBCs).

More information

Blood Bank Review. Case #1 ABO/Rh. Case #1 Antibody Screen. Is the ABO grouping discrepant? No Interpretation: O positive

Blood Bank Review. Case #1 ABO/Rh. Case #1 Antibody Screen. Is the ABO grouping discrepant? No Interpretation: O positive Blood Bank Review Mary Burroughs Blood Bank Technical Specialist Mercy Health Saint Mary s Case #1 ABO/Rh Forward Grouping Reverse Grouping Anti-A Anti-B Anti-D A1 cells B cells 0 0 3+ 4+ 4+ Is the ABO

More information

POL:07:QP:010:03:NIBT PAGE: 1 of 4. Document Details Document Number: POL:07:QP:010:03:NIBT No. of Appendices: 4 Supersedes Number: 07:02:QP:010:NIBT

POL:07:QP:010:03:NIBT PAGE: 1 of 4. Document Details Document Number: POL:07:QP:010:03:NIBT No. of Appendices: 4 Supersedes Number: 07:02:QP:010:NIBT POL:07:QP:010:03:NIBT PAGE: 1 of 4 POLICY DOCUMENT Document Details Document Number: POL:07:QP:010:03:NIBT No. of Appendices: 4 Supersedes Number: 07:02:QP:010:NIBT Document Title: INTERNAL QUALITY CONTROL

More information

Expertise. Specialty Products Complete the puzzle with the industry s most comprehensive line of products for transfusion diagnostics.

Expertise. Specialty Products Complete the puzzle with the industry s most comprehensive line of products for transfusion diagnostics. Expertise. Specialty Products Complete the puzzle with the industry s most comprehensive line of products for transfusion diagnostics. For 30 years, Immucor has been a dedicated partner to your Blood Bank

More information

Antibody - Antigen Reactions: ABO and D typing Antibody screening and identification

Antibody - Antigen Reactions: ABO and D typing Antibody screening and identification Antibody - Antigen Reactions: ABO and D typing Antibody screening and identification Basics of antigen/ antibody reactions Why is the ABO group so special? D antigen it s complicated! Antibody screen Antibody

More information

RCPAQAP TRANSFUSION TRANSFUSION COMPETENCY PROGRAM METHOD CLASSIFICATION MASTERLIST

RCPAQAP TRANSFUSION TRANSFUSION COMPETENCY PROGRAM METHOD CLASSIFICATION MASTERLIST A.B.N: 32 003 520 072 RCPAQAP TRANSFUSION TRANSFUSION COMPETENCY PROGRAM METHOD CLASSIFICATION MASTERLIST 2013 Before 1 July 2013 After 1 July 2013 RCPAQAP Transfusion RCPAQAP Centre Of Excellence PO Box

More information

Erythrocyte-magnetized technology (EMT;

Erythrocyte-magnetized technology (EMT; IMMUNOHEMATOLOGY Erythrocyte-magnetized technology: an original and innovative method for blood group serology Olivier Bouix, Virginie Ferrera, Maryvonne Delamaire, Jean Claude Redersdorff, and Francis

More information

When, autoimmune hemolytic anemia

When, autoimmune hemolytic anemia IMMUNOHEMATOLOGY Adsorption of autoantibodies in the presence of LISS to detect alloantibodies underlying warm autoantibodies Jacques Chiaroni, Mohammed Touinssi, Magali Mazet, Philippe de Micco, and Virginie

More information

Georgia Spanos, MT LifeSouth Community Blood Centers Gainesville, Fl. SEABB March 2017

Georgia Spanos, MT LifeSouth Community Blood Centers Gainesville, Fl. SEABB March 2017 Georgia Spanos, MT LifeSouth Community Blood Centers Gainesville, Fl. SEABB March 2017 Case Study 1 Patient Demographics -44 year old -African-American Female -Diagnosis: Gastroenteritis -Facility reported

More information

IH-500. Innovation Driven by Experience. Bio-Rad is one of the world s most respected suppliers of blood screening systems.

IH-500. Innovation Driven by Experience. Bio-Rad is one of the world s most respected suppliers of blood screening systems. Immunohematology IH-500 Fully Automated System for ID-Cards IH-500 Innovation Driven by Experience Bio-Rad is one of the world s most respected suppliers of blood screening systems. We have been serving

More information

Rx ONLY

Rx ONLY Blood Grouping Reagent Anti-D (Anti-Rh o ) (Human Monoclonal-Polyclonal Blend) BioClone For Rapid Tube, Slide and Microplate Tests Qualitative Test for Recognition of the D(Rh o ) Antigen on Human Red

More information

VALIDATION OF AN AUTOMATED ANTIGLOBULIN TEST MACHINE THE LORNE ACT-24. Zs. SZABÓ, É.K. BENKÖ, J. BUCZKO, Á. FRISS* D.M. DOWNIE+ AND D.

VALIDATION OF AN AUTOMATED ANTIGLOBULIN TEST MACHINE THE LORNE ACT-24. Zs. SZABÓ, É.K. BENKÖ, J. BUCZKO, Á. FRISS* D.M. DOWNIE+ AND D. VALIDATION OF AN AUTOMATED ANTIGLOBULIN TEST MACHINE THE LORNE ACT-24 Zs. SZABÓ, É.K. BENKÖ, J. BUCZKO, Á. FRISS* D.M. DOWNIE+ AND D. VOAK + CYTOTECH INSTRUMENTS LTD., BUDAPEST, HUNGARY. *CENTRAL MILITARY

More information

Serological Testing: Why we did what we did!

Serological Testing: Why we did what we did! Serological Testing: Why we did what we did! W. John Judd, FIBMS, MIBiol Emeritus Professor University of Michigan What we did Provided blood and blood products in a timely, cost-efficient manner. Implemented

More information

Brilliant Performance. Clear Results.

Brilliant Performance. Clear Results. From the inside out Maximum support Increase efficiency, accuracy and flexibility with the redesigned Echo Lumena, our high performing, fully automated blood bank system. You can depend on us. With over

More information

GEL CARD AND SALINE TUBE TECHNIQUES FOR BLOOD CROSS MATCHING: A COMPARATIVE ASSESSMENT

GEL CARD AND SALINE TUBE TECHNIQUES FOR BLOOD CROSS MATCHING: A COMPARATIVE ASSESSMENT GEL CARD AND SALINE TUBE TECHNIQUES FOR BLOOD CROSS MATCHING: A COMPARATIVE ASSESSMENT Mahamat Ahmat Aboussakine 1, Dr. Kalpana Sankhala 2 1 MSc Blood Transfusion Technologym. NIMS University,Jaipur Rajasthan,

More information

Definitions. Absorption/Adsorption and Elution. Elution. CLS 422 Clinical Immunohematology I Absorption and Elution 1

Definitions. Absorption/Adsorption and Elution. Elution. CLS 422 Clinical Immunohematology I Absorption and Elution 1 Definitions Absorption/Adsorption and Elution CLS 422 Clinical Immunohematology I Absorption: To remove antibodies from serum through the action of the target antigen. Adsorption: The uptake of antibody

More information

GUIDELINES FOR PRETRANSFUSION TESTING : PART I

GUIDELINES FOR PRETRANSFUSION TESTING : PART I Commissie voor Klinische Biologie Commission de Biologie Clinique GUIDELINES FOR PRETRANSFUSION TESTING : PART I Dr. A. Vanhonsebrouck, Bloedtransfusiecentrum Antwerpen 26-03-2009 WIV congress Rue Juliette

More information

Susan T. Johnson, MSTM, MT(ASCP)SBB BloodCenter of Wisconsin Milwaukee, WI USA

Susan T. Johnson, MSTM, MT(ASCP)SBB BloodCenter of Wisconsin Milwaukee, WI USA Laboratory Investigation of Hemolytic Transfusion Reactions Speaker Professor A Pourazar Susan T Johnson, MSTM, MT(ASCP)SBB BloodCenter of Wisconsin Milwaukee, WI USA Laboratory Evaluation of Transfusion

More information

VII. Rh Blood Group System

VII. Rh Blood Group System VII. Rh Blood Group System A. The Rh system is one of the most complex genetic systems, and certain aspects of its genetics, nomenclature and antigenic interactions are unsettled. The aim of this lecture

More information

Ain t Nobody Got Time for

Ain t Nobody Got Time for Ain t Nobody Got Time for DATs Lindsay Peters MLS(ASCP)SBB Reference Laboratory Supervisor Mississippi Valley Regional Blood Center OBJECTIVES Define and describe the antiglobulin test. Identify the reagents

More information

It s in the Details Problems with Blood Bank Testing You Never Saw Coming

It s in the Details Problems with Blood Bank Testing You Never Saw Coming It s in the Details Problems with Blood Bank Testing You Never Saw Coming Heart of America April 17, 2018 Presented by Rebecca Bullock, MT(ASCP)SBB Technical Director, Quotient Biodiagnostics I have come

More information

The MR.SPOT Platform. MR.SPOT 2.0 available NOW! Flexible solutions for different applications in transfusion and transplantation

The MR.SPOT Platform. MR.SPOT 2.0 available NOW! Flexible solutions for different applications in transfusion and transplantation Upgraded Version MR.SPOT 2.0 available NOW! The MR.SPOT Platform Flexible solutions for different applications in transfusion and transplantation BAG Health Care the Experts for HLA and Blood Group Diagnostics

More information

STANDARD OPERATING PROCEDURE FOR QUALITY CONTROL OF REAGENTS AND ANTISERA

STANDARD OPERATING PROCEDURE FOR QUALITY CONTROL OF REAGENTS AND ANTISERA STANDARD OPERATING PROCEDURE FOR QUALITY CONTROL OF REAGENTS AND ANTISERA TITLE: STANDARD OPERATING PROCEDURE FOR QUALITY CONTROL OF REAGENTS AND ANTISERA 1.0 Principle 1.1 The purpose of quality control

More information

4/12/2019. Handouts Advanced Track Webinars. us/pages/educational Program Handouts.aspx

4/12/2019. Handouts Advanced Track Webinars.   us/pages/educational Program Handouts.aspx Handouts http://www.immucor.com/en us/pages/educational Program Handouts.aspx 2 All Content Immucor, Inc. 2019 Advanced Track Webinars Link to register: https://immucor.webinato.com/register 3 All Content

More information

Cell-Based ELISA. Catalog Number K E. Cell-Based ELISA to Characterize Human Breast Cancer Stem Cell in culture.

Cell-Based ELISA. Catalog Number K E. Cell-Based ELISA to Characterize Human Breast Cancer Stem Cell in culture. Cell-Based ELISA Catalog Number K36102-29E Cell-Based ELISA to Characterize Human Breast Cancer Stem Cell in culture. This package insert must be read in its entirety before using this product. FOR RESEARCH

More information

INSTRUCTIONS FOR USE. BLOOD GROUPING REAGENT ORTHO Sera Anti-Le a (Anti-LE1) ORTHO Sera Anti-Le b (Anti-LE2)

INSTRUCTIONS FOR USE. BLOOD GROUPING REAGENT ORTHO Sera Anti-Le a (Anti-LE1) ORTHO Sera Anti-Le b (Anti-LE2) BLOOD GROUPING REAGENT ORTHO Sera Anti-Le a (Anti-LE1) ORTHO Sera Anti-Le b (Anti-LE2) 6904497 6904498 Intended Use For in vitro diagnostic use only For Direct Agglutination Test by Column Agglutination

More information

Resolve Panel A A Qualitative Test for the Identification of Unexpected Blood Group Antibodies

Resolve Panel A A Qualitative Test for the Identification of Unexpected Blood Group Antibodies Revised October 2015 Reagent Red Blood Cells Resolve Panel A A Qualitative Test for the Identification of Unexpected Blood Group Antibodies 719510 Rx ONLY SUMMARY AND EXPLANATION When an unexpected antibody

More information

Use of low ionic strength saline for crossmatching

Use of low ionic strength saline for crossmatching Journal of Clinical Pathology, 1979, 32, 1019-1024 Use of low ionic strength saline for crossmatching and antibody screening J. A. G. LOWN, A. L. BARR, AND R. E. DAVIS From the Department of Haematology,

More information

Blood Grouping Reagent IH-Anti-D (RH1) Blend

Blood Grouping Reagent IH-Anti-D (RH1) Blend Blood Grouping Reagent IH-Anti-D (RH1) Blend English, B186530, Version 07, 2018.11 FOR IN VITRO DIAGNOSTIC USE Anti-D reagent for use with IH-System MEETS FDA POTENCY REQUIREMENTS U.S. License Number:

More information

Carol A Starks MS, MLS(ASCP), CLS. castarks

Carol A Starks MS, MLS(ASCP), CLS. castarks Carol A Starks MS, MLS(ASCP), CLS Brief review of the common blood groups ABO Rh Kell Duffy Kidd P Lutheran MNS Lewis Basic Blood Bank workups ABO discrepancies Single antibody not demonstrating Single

More information

Antibody Identification: Art or Science? A Case Study Approach

Antibody Identification: Art or Science? A Case Study Approach Antibody Identification: Art or Science? A Case Study Approach (Questions and Answers) Editors Janis R. Hamilton, MS, MT(ASCP)SBB Susan T. Johnson, MSTM, MT(ASCP)SBB Sally V. Rudmann, PhD, MT(ASCP)SBB

More information

Using EQA to improve practice - highlights 2017/18. Richard Haggas UK NEQAS Blood Transfusion Laboratory Practice

Using EQA to improve practice - highlights 2017/18. Richard Haggas UK NEQAS Blood Transfusion Laboratory Practice Using EQA to improve practice - highlights 2017/18 Richard Haggas UK NEQAS Blood Transfusion Laboratory Practice BTLP Reports - Look at the front sheet - No penalties - May look to the graphs BTLP Reports

More information

Quotient Limited. Jefferies Healthcare Conference. June 2017

Quotient Limited. Jefferies Healthcare Conference. June 2017 Quotient Limited Jefferies Healthcare Conference June 2017 Safe Harbor Statement This presentation contains forward-looking statements within the meaning of Section 27A of the Securities Act of 1933 and

More information

CytoGLOW. IKK-α/β. Colorimetric Cell-Based ELISA Kit. Catalog #: CB5358

CytoGLOW. IKK-α/β. Colorimetric Cell-Based ELISA Kit. Catalog #: CB5358 CytoGLOW IKK-α/β Colorimetric Cell-Based ELISA Kit Catalog #: CB5358 Please read the provided manual entirely prior to use as suggested experimental protocols may have changed. Research Purposes Only.

More information

Examination of the feasibility of establishing a peer reviewed external quality assessment scheme for red blood cell antibody eluate investigations

Examination of the feasibility of establishing a peer reviewed external quality assessment scheme for red blood cell antibody eluate investigations Examination of the feasibility of establishing a peer reviewed external quality assessment scheme for red blood cell antibody eluate investigations Janet Murphy, Dublin Institute of Technology. John Crumlish,

More information

DiviTum V2. User s Manual IVD. This User s Manual is intended for DiviTum V2. For use in the United States and Japan only for research purposes

DiviTum V2. User s Manual IVD. This User s Manual is intended for DiviTum V2. For use in the United States and Japan only for research purposes DiviTum V2 User s Manual This User s Manual is intended for DiviTum V2 For use in the United States and Japan only for research purposes IVD 40 Ref. 933 rev. EN 2 1 Contents DIVITUM ASSAY FOR MEASURING

More information

Tools and Strategies Useful for Antibody Identification. Virginia Hare, MT(ASCP)SBB Immunohematology Reference Lab American Red Cross Southern Region

Tools and Strategies Useful for Antibody Identification. Virginia Hare, MT(ASCP)SBB Immunohematology Reference Lab American Red Cross Southern Region Tools and Strategies Useful for Antibody Identification Virginia Hare, MT(ASCP)SBB Immunohematology Reference Lab American Red Cross Southern Region 1 st case: 85 y.o. white female Admitted for a total

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK - Edinburgh SNBTS Edinburgh Clinical Laboratories Royal Infirmary Edinburgh Little France Crescent EH16 4SA Contact: Symon Lockhart Tel: +44

More information

High Sensitive Rat Leptin ELISA

High Sensitive Rat Leptin ELISA High Sensitive Rat Leptin ELISA For the high sensitive quantitative determination of Leptin in rat serum or plasma. Cat. No. KT-379 For Research Use Only. 1 Rev. 091707 PRODUCT INFORMATION High Sensitive

More information

e-grips Module 18 Introduction to Antibody Identification

e-grips Module 18 Introduction to Antibody Identification Introduction to Antibody Identification Introduction Objectives After completing the learning module, the learner will be able to: 1. Discuss the limitations of antibody detection and identification. 2.

More information

HUMAN LBP Quantification ELISA

HUMAN LBP Quantification ELISA HUMAN LBP Quantification ELISA For the quantitative determination of natural and recombinant human LBP in serum, plasma and culture medium Cat. No. KT-1004 For Research Use Only. Not for use in diagnostic

More information

Objectives. Martin Health System 5/10/2016

Objectives. Martin Health System 5/10/2016 Immucor User Group Meeting Boca Raton, Florida May 12, 2016 Patricia Houtz BS, MT (ASCP) Martin Health System Blood Bank Supervisor Objectives Describe Martin s antibody resolution workflow Illustrate

More information

VIII. Pretransfusion Compatibility Testing

VIII. Pretransfusion Compatibility Testing VIII. Pretransfusion Compatibility Testing A. The purpose of pretransfusion testing is to select, for each recipient, blood components that, when transfused, will have acceptable survival and will not

More information

Acceptable Student Result Range Identify with 100% accuracy any alloantibody in a patient serum sample.

Acceptable Student Result Range Identify with 100% accuracy any alloantibody in a patient serum sample. Name Panel Studies Principle If positive reactions (agglutination and/or hemolysis) are obtained at any phase of the antibody screen or crossmatch procedure, a panel study must be performed. Positive reactions

More information

Automated Protocol for ANTI-FLAG High Sensitivity, M2 coated 96-well plate Using the Sciclone ALH 3000 Workstation (Caliper Life Sciences)

Automated Protocol for ANTI-FLAG High Sensitivity, M2 coated 96-well plate Using the Sciclone ALH 3000 Workstation (Caliper Life Sciences) Automated Protocol for ANTI-FLAG High Sensitivity, M2 coated 96-well plate Using the Sciclone ALH 3000 Workstation (Caliper Life Sciences) ANTI-FLAG High Sensitivity, M2 coated 96-well plate P 2983 Automation

More information

Instructions for Use

Instructions for Use Mouse Ovalbumin-Specific IgE ELISA Kit Catalogue code: MCA2475KZZ FOR INVITRO USE AND RESEARCH USE ONLY NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES Instructions for Use Intended Use This ELISA

More information

HUMAN IgG. Immunoperoxidase Assay for Determination of IgG in Human Samples

HUMAN IgG. Immunoperoxidase Assay for Determination of IgG in Human Samples HUMAN IgG Immunoperoxidase Assay for Determination of IgG in Human Samples DIRECTIONS FOR USE Version3 L30A 31 For Research Use Only, NOT for Diagnostic Purposes Please Read this Package Insert Completely

More information

IH-1000 Fully Automated System for ID-Cards

IH-1000 Fully Automated System for ID-Cards Bio-Rad Laboratories IMMUNOHEMATOLOGY IH-1000 Fully Automated System for ID-Cards The Complete Solution for Safe Transfusion Bio-Rad Laboratories IMMUNOHEMATOLOGY IH-1000 The Ideal Solution for Immunohematology

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Welsh Service Ely Valley Road Talbot Green Pontyclun CF71 9WB Contact: Dr Tracey Rees Tel: +44 (0) 1443 622000 / (0) 1443 622175 Fax: +44

More information

MULTISPECIES LBP Quantification ELISA

MULTISPECIES LBP Quantification ELISA MULTISPECIES LBP Quantification ELISA For the quantitative determination of natural and recombinant human, bovine, pig, rabbit, dog LBP in serum, plasma and culture medium Cat. No. KT-1005 For Research

More information

INOS. Colorimetric Cell-Based ELISA Kit. Catalog #: OKAG00807

INOS. Colorimetric Cell-Based ELISA Kit. Catalog #: OKAG00807 INOS Colorimetric Cell-Based ELISA Kit Catalog #: OKAG00807 Please read the provided manual entirely prior to use as suggested experimental protocols may have changed. Research Purposes Only. Not Intended

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK National Health Service Blood and Transplant International Blood Group Reference Laboratory 500 North Filton Park Filton Bristol BS34 7QH

More information

RayBio Human IgG1 ELISA Kit

RayBio Human IgG1 ELISA Kit RayBio Human IgG1 ELISA Kit Catalog #: ELH-IGG1 User Manual Last revised April 15, 2016 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite 100 Norcross, GA

More information

Reagent Red Blood Cells 0.8% Surgiscreen For the Detection of Unexpected Blood Group Antibodies Using the ID-Micro Typing System Gel Test Methods

Reagent Red Blood Cells 0.8% Surgiscreen For the Detection of Unexpected Blood Group Antibodies Using the ID-Micro Typing System Gel Test Methods Reagent Red Blood Cells 0.8% Surgiscreen For the Detection of Unexpected Blood Group Antibodies Using the ID-Micro Typing System Gel Test Methods Revised October 2015 REF 6902316 Rx ONLY SUMMARY AND EXPLANATION

More information

ScanGel COOMBS + NEUTRAL Cards Cards

ScanGel COOMBS + NEUTRAL Cards Cards ScanGel COOMBS + NEUTRAL 86433 48 Cards 86434 1080 Cards GEL FORMULATED WITH A POLYSPECIFIC ANTI HUMAN GLOBULIN (POLYCLONAL AND MONOCLONAL MURINE FRACTIONS) AND NEUTRAL GEL Irregular Ab screening IVD All

More information

Rat glutathione S-transferase Yb1 ELISA

Rat glutathione S-transferase Yb1 ELISA Rat glutathione S-transferase Yb1 ELISA For quantitative determination of glutathione S-transferase Yb1 in rat samples. Please See Appendix A for Reference Serum Information For Research Use Only. Not

More information

I want my lab to run better. There are many companies that provide products and services to the blood bank, but there is only one that has answered

I want my lab to run better. There are many companies that provide products and services to the blood bank, but there is only one that has answered I want my lab to run better. There are many companies that provide products and services to the blood bank, but there is only one that has answered your call to bring the benefits of automation to labs

More information

Manual. Catalog number:

Manual. Catalog number: LLAMA IGG ELISA Quantitation Kit Manual Catalog number: 40-374-130033 Immunoperoxidase Assay for Determination of Llama IgG in Llama serum/plasma. This kit is for research use only, and is not for use

More information

Sheep IgG ELISA Kit. Innovative Research, Inc. Catalog No: ISHIGGKT. Lot No: SAMPLE

Sheep IgG ELISA Kit. Innovative Research, Inc. Catalog No: ISHIGGKT. Lot No: SAMPLE Catalog No: ISHIGGKT Sheep IgG ELISA Kit Lot No: SAMPLE INTENDED USE The total Sheep IgG test kits are a highly sensitive two-site enzyme linked immunoassay (ELISA) for measuring IgG in sheep biological

More information

Immunohematology Case Studies PD Dr. med. Franz F Wagner Red Cross Blood Service NSTOB

Immunohematology Case Studies PD Dr. med. Franz F Wagner Red Cross Blood Service NSTOB Immunohematology Case Studies 2016-5 PD Dr. med. Franz F Wagner Red Cross Blood Service NSTOB fwagner@bsd-nstob.de Clinical History A 78 yrs old patient had coronary artery bypass surgery. In the perioperative

More information

EGFR (Phospho-Ser695)

EGFR (Phospho-Ser695) Assay Biotechnology Company www.assaybiotech.com Tel: 1-877-883-7988 Fax: 1-877-610-9758 EGFR (Phospho-Ser695) Colorimetric Cell-Based ELISA Kit Catalog #: OKAG02090 Please read the provided manual entirely

More information

Fully Automated EIA System. True open flexibility.

Fully Automated EIA System. True open flexibility. True open flexibility www.triturus.com The immunoassay analyzer of choice: completely open, fully automated, multi-test and multi-batch. TRUE OPEN FLEXIBILITY What is Triturus? Triturus is a completely

More information