RT Workspace from Standard Imaging

Size: px
Start display at page:

Download "RT Workspace from Standard Imaging"

Transcription

1 RT Workspace from Standard Imaging

2 In 1895 Wilhelm Röntgen discovers the X-ray (receives Nobel prize in 1901) From radium was chiefly used for radiation treatment (based on work of Marie Curie who received 2 nobel prizes for her work)

3 The Cobalt Bomb developed in the early 1950 s The first machine capable of irradiating tissues deep inside the body Aim and shoot

4 From 1950 to 1970 the linear accelerator was developed and improved In 1971 the CT was introduced and 3D planning became a possibility No longer point and shoot

5 MRI introduced in the 1970s PET introduced in the 1980s MLCs and IMRT introduced in the 1990s IGRT introduced in the 2000s With more complicated machines and treatment techniques comes more complicated planning

6 Physician Consult (Physician) Plan Second Check (Physicist) Weekly Chart Audit (Therapist) Desk Notification (Front Desk) Treatment Scheduling (Tx Scheduler) Simulation (Physician, Therapist) Treatment Planning Treatment Planning (Physician, Dosimetrist, Physicist) Dosimetrist, Physicist) Daily Patient Specific QA (Physicist) Treatment Delivery (Therapist) Review of Images (Physician) Weekly Weekly Chart Check (Physicist) Weekly Management Visit (Physician) Completion of Treatment (Front Desk, Tx Scheduler)

7 Patient Volume Imaging (Imaging Tech) Images/Patient set up in TPS (Dosimetrist) Treatment volumes Contoured and Rx (Physician) Plan Creation (Dosimetrist) Plan Review (Physician, Physicist) Move plan to R&V (Dosimetrist) Order Beam Modifiers (Dosimetrist) Prepare plan for IGRT (Dosimetrist) Prepare plan for QA (IMRT) (Dosimetrist) Print the plan (Dosimetrist) Billing (Dosimetrist) Treatment preparation Plan QA (Physicist) Collect QA data (Physicist) Analyze QA data (Physicist) Prepare QA reports (Physicist) Billing (Physicist) Plan QA

8 Satellite Clinic A 25 Km West Main Hospital Satellite Clinic B 25 Km East

9 Developed in a group of clinics to solve a problem Wanted a solution that could be accessed from any computer Wanted a solution that would automatically notify each person when a process required their attention Wanted a solution that was intuitive so that any user could be up and running in a minimal amount of time

10 SQL Server Database Full SQL Server recommended but SQL Server Express can be used (free) Can be network based or web based Client software can be installed on any computer that has access to the database

11 Filter and Sort A filter bar allows the user to filter the board on any column s information. Clicking a column header sorts the board based on that column s information The Workflow Boards All tasks necessary to complete a radiotherapy plan are tracked. Clicking on the board to complete a task automatically lets the next person in line know that they have a new task to complete Colleague s ToDo List View any other RT Workspace user s ToDo list perfect for covering during vacations, etc.. Personal ToDo List Items are added automatically from the boards or manually by any RT Workspace user in a single glance know exactly what tasks need your attention

12 Planner Physician

13

14 With improved communication every team member can function more efficiently Physicians know in a single glance what is required of them Dosimetrists spend more time on planning instead of searching out answers to questions Therapists don t have to worry about making sure their patients are ready to start treatment

15 A dosimetrist reduces their unproductive time 15% (1.2 hours per day recovered) That equates to $14,400 per year* in recovered productivity Three dosimetrists = $43,200 per year Multiple sites??? *salary.com May 2011 Average medical dosimetrist salary = $96,825/year

16 RT Workspace was invented by a physicist so there are several tools built into the software specifically for physics Detailed equipment manager includes tracking calibrations and notifying when calibrations are due TG142 Monthly Linac QA Module Patient specific IMRT QA Module Electron cutout output factor module

17 In a single glance know where every patient is in the planning process Increase efficiency and productivity throughout the clinic Happier team members and more satisfied patients

18 Neal Miller Product Manager Standard Imaging, Inc.

19 The TaskGroup 142 report : Quality assurance of medical accelerators specifically spells out QA for imaging systems used in radiotherapy Planar MV and kv imaging (Monthly) Scaling Spatial resolution Contrast Noise Uniformity

20 The TaskGroup 142 report : Quality assurance of medical accelerators specifically spells out QA for imaging systems used in radiotherapy Cone Beam CT (Monthly) Geometric Distortion Spatial resolution Contrast HU Constancy Noise Uniformity

21 Some Machine QA Tasks that are called for in TG 142 Light/radiation field congruence Collimator, gantry and couch rotation isocenter (starshot) Jaw Positioning Radiation vs mechanical isocenter MLC Tests

22 PIPSpro QC Software measures MV and kv imager performance allowing you to quantify the quality of your imaging systems and track the degradation over time. Powerful analysis engines allow for important machine parameter testing

23 Invented by one of the physicists that was on the team that invented the Las Vegas phantom included with most imagers Realized that a subjective test wasn t good enough and could result in acceptance even with poor image quality The QC-3 phantom and PIPSpro were invented to provide objective, quantifiable and repeatable results for image quality Las Vegas Phantom QC-3 Phantom and stand

24 Developed for on board kv imaging systems including Varian, Elekta and Cyberknife Custom stand for Cyberknife systems uses fiducial tracking tools on the Cyberknife system to automatically position for image acquisition

25 MV (EPID) and kv (OBI) Imager QC The QC-3 phantom (MV) and the QCkV-1 phantom (kv) provide quantitative results for resolution, contrast-to -noise and overall noise of the imaging system

26 There are over 55 publications that validate the use of PIPSpro software and published results exist for most MV imagers of what to expect when utilizing PIPSpro software and the QC-3 phantom. With these published results it is easy to verify whether your imager is performing to specification.

27 Cone-beam CT testing CBCT module automatically analyzes image sets of the CATPHAN phantom included with Varian and Elekta systems Comprehensive QA of the CBCT imaging system in less than a minute!

28 Powerful analysis engines allow PIPSpro to perform important TG142 machine parameter testing utilizing specialized phantoms and your machine s imaging system Radiation Field/Light Field alignment tests Jaw position testing Gantry, couch and collimator rotation analysis (starshots) Stereotactic isocenter alignment test (Lutz test) MLC testing

29 The TaskGroup 142 report : Quality assurance of medical accelerators specifically spells out QA for imaging systems used in radiotherapy Planar MV and kv imaging (Monthly) Scaling Spatial resolution Contrast Noise Uniformity (Coming Soon)

30 The TaskGroup 142 report : Quality assurance of medical accelerators specifically spells out QA for imaging systems used in radiotherapy Cone Beam CT (Monthly) Geometric Distortion Spatial resolution Contrast HU Constancy Noise Uniformity

31 Other TG142 tasks that are covered by the tools in PIPSpro Light/radiation field congruence Collimator, gantry and couch rotation isocenter (starshot) Radiation vs mechanical isocenter (stereo) Jaw Positioning MLC Tests

32 Quantitative, repeatable results for imager quality including kv and CBCT testing Complete most TG142 tasks for imager quality assurance quickly, easily and accurately Recommended in the TG58 report on Clinical use of electronic portal imaging Perform important TG142 machine QA Speed up QA by using imagers and powerful analysis engines in PIPSpro eliminating the need to use film.

AAPM IGRT Recommendations

AAPM IGRT Recommendations AAPM IGRT Recommendations Joint ICTP-IAEA International Workshop on the Implementation of Image Guided Radiotherapy (IGRT) 8-12 May 2017 J. Daniel Bourland, PhD, DABR Professor, Departments of Radiation

More information

Nathan Childress, Ph.D., DABR

Nathan Childress, Ph.D., DABR Nathan Childress, Ph.D., DABR Financial Disclaimer I own Mobius Medical Systems, LP, manufacturer of Mobius3D, MobiusFX, and DoseLab I used Mobius3D to generate results for this talk Introduction Dosimetrists

More information

TG142 Quality Assurance of Medical Accelerators

TG142 Quality Assurance of Medical Accelerators TG142 Quality Assurance of Medical Accelerators Joe Hanley, Ph.D. Hackensack University Medical Center, Hackensack NJ TG142 MEMBERS Chair: Eric E. Klein, Ph.D., Washington University Joe Hanley, Ph.D.,

More information

This is probably the kind of radiotherapy that you are used to delivering in your country.

This is probably the kind of radiotherapy that you are used to delivering in your country. This is probably the kind of radiotherapy that you are used to delivering in your country. This slide shows images two patients, one with a T3 N2c nasopharyngeal CA and the other with a T1/2 N1/2 lung

More information

Treatment Quality Assurance Cone Beam Image Guided Radiation Therapy. Jean-Pierre Bissonnette, PhD, MCCPM

Treatment Quality Assurance Cone Beam Image Guided Radiation Therapy. Jean-Pierre Bissonnette, PhD, MCCPM Treatment Quality Assurance Cone Beam Image Guided Radiation Therapy Jean-Pierre Bissonnette, PhD, MCCPM Disclosure Work supported, in part, by Elekta Oncology Systems Commercial Interest in Penta-Guide

More information

Approved [insert date]*

Approved [insert date]* Page 1 of 33 1 The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical

More information

Technical White Paper: An Educational Report On Helical IMRT EXECUTIVE SUMMARY. CRCPD Publication #E-11-3

Technical White Paper: An Educational Report On Helical IMRT EXECUTIVE SUMMARY. CRCPD Publication #E-11-3 CRCPD Publication #E-11-3 Technical White Paper: An Educational Report On Helical IMRT Developed by CRCPD s H-34 Task Force for Helical IMRT EXECUTIVE SUMMARY Helical IMRT (Intensity Modulated Radiation

More information

RayStation Automation is the Future of Planning. Carmen Sawyers, MS, DABR Ackerman Cancer Center

RayStation Automation is the Future of Planning. Carmen Sawyers, MS, DABR Ackerman Cancer Center RayStation Automation is the Future of Planning Carmen Sawyers, MS, DABR Ackerman Cancer Center Overview Why Automation? o RayStation Automation Tools A Different Approach o RayStation Advanced Automation

More information

The Role of In-Room kv X-Ray Imaging for Patient Setup and Target Localization (TG104)

The Role of In-Room kv X-Ray Imaging for Patient Setup and Target Localization (TG104) The Role of In-Room kv X-Ray Imaging for Patient Setup and Target Localization (TG104) John Wong (jwong35@jhmi.edu) David Jaffray (David.Jaffray@rmp.uhn.on.ca) Fang-Fang Yin (fangfang.yin@duke.edu) AAPM

More information

ViewRay Experience. Sasa Mutic, Ph.D. Washington University School of Medicine

ViewRay Experience. Sasa Mutic, Ph.D. Washington University School of Medicine ViewRay Experience Sasa Mutic, Ph.D. Washington University School of Medicine You can observe a lot, just by watching -Yogi Berra Does organ motion matter? A slide often used to illustrate RT capabilities

More information

PerFRACTION 3D. 3D Pre-Treatment QA and In-Vivo Monitoring. Your Most Valuable QA and Dosimetry Tools. SunCHECK

PerFRACTION 3D. 3D Pre-Treatment QA and In-Vivo Monitoring. Your Most Valuable QA and Dosimetry Tools. SunCHECK PerFRACTION 3D 3D Pre-Treatment QA and In-Vivo Monitoring SunCHECK Your Most Valuable QA and Dosimetry Tools AUTOMATE YOUR QA PerFRACTION listens for and captures your pre-treatment and in-vivo QA files

More information

The VALUE of Medical Physicists at a Community Medical Center

The VALUE of Medical Physicists at a Community Medical Center D D d The VALUE of Medical Physicists at a Community Medical Center Without medical physicists this place could not function properly (Yes, we re crazy) Jeremy Donaghue Jeremy.donaghue@akrongeneral.org

More information

Going Clinical with the Accuray Radixact System. The Montefiore Experience

Going Clinical with the Accuray Radixact System. The Montefiore Experience Going Clinical with the Accuray Radixact System The Montefiore Experience Disclaimer The views expressed in the presentation are those of the presenters and do not necessarily reflect the views or policies

More information

Thanks to Jeff Williamson, Mike Steinberg, James Purdy

Thanks to Jeff Williamson, Mike Steinberg, James Purdy Thanks to Jeff Williamson, Mike Steinberg, James Purdy Radiation Therapy 1.6M new cancer cases this year in US Approximately 60% of cancer patients receive radiation therapy during the course of their

More information

Quality Assurance for particle beam therapy

Quality Assurance for particle beam therapy Quality Assurance for particle beam therapy PTCOG Educational Workshop, Essen 2013 Heidelberg Ion Beam Therapy Center at the University Hospital German Cancer Research Center, Heidelberg, Germany Outline

More information

RapidArc: Clinical Implementation

RapidArc: Clinical Implementation RapidArc: Clinical Implementation Fang-Fang Yin, PhD Q. Jackie Wu, PhD Acknowledgements Team efforts from staff at Duke Radiation Oncology, especially to Dr. J Chang, Dr. J O Daniel for providing slide

More information

TG-104: In-room kv Computed Tomography for Image-guidance

TG-104: In-room kv Computed Tomography for Image-guidance TG-104: In-room kv Computed Tomography for Image-guidance D.A. Jaffray, Ph.D. Radiation Medicine Program Princess Margaret Hospital/Ontario Cancer Institute Professor Departments of Radiation Oncology

More information

Optimizing Treatment Planning Process in Clinical Enviroment

Optimizing Treatment Planning Process in Clinical Enviroment Optimizing Treatment Planning Process in Clinical Enviroment Wenzheng Feng 12 (1) Columbia University Medical Center, New York, NY (2) Bayhealth Medical Center, Dover, DE Objectives: 1. Be familiar with

More information

AAPM Medical Physics Practice Guideline 8.a.: Linear accelerator performance tests

AAPM Medical Physics Practice Guideline 8.a.: Linear accelerator performance tests Received: 30 January 2017 Revised: 28 February 2017 Accepted: 6 March 2017 DOI: 10.1002/acm2.12080 AAPM REPORTS & DOCUMENTS AAPM Medical Physics Practice Guideline 8.a.: Linear accelerator performance

More information

Tra n s m is s ion dete c to r fo r a t-t re a t m e n t Q A

Tra n s m is s ion dete c to r fo r a t-t re a t m e n t Q A Tra n s m is s ion dete c to r fo r a t-t re a t m e n t Q A Confidence Safety Accuracy Efficiency The innovative Delta4 Discover transmission detector provides confidence and patient safety based on real

More information

Dosimetry of Small IMRT Fields

Dosimetry of Small IMRT Fields Dosimetry of Small IMRT Fields Parham Alaei, Ph.D. Department of Radiation Oncology University of Minnesota NCCAAPM Symposium-October 10, 2013 1 IMRT and Small Fields IMRT beams typically contain small

More information

SPECIFICATION STATEMENT OF WORK. Performance Specification for a radiotherapy linear accelerator

SPECIFICATION STATEMENT OF WORK. Performance Specification for a radiotherapy linear accelerator Specifications / Statement of Work / Terms of Reference SPECIFICATION STATEMENT OF WORK Performance Specification for a radiotherapy linear accelerator 1. Scope These specifications describe the requirements

More information

} } 8/3/2016. Accounting for kv Imaging Dose. kilovoltage imaging devices/techniques. Current imaging dose determination methods

} } 8/3/2016. Accounting for kv Imaging Dose. kilovoltage imaging devices/techniques. Current imaging dose determination methods Accounting for kv Imaging Dose Parham Alaei, Ph.D. Department of Radiation Oncology University of Minnesota 1 2016 AAPM Annual Meeting - SAM Therapy Educational Course, TU-B-201-2 Washington, DC, August

More information

Integrating the MR-Linac into Radiation Therapy Practice

Integrating the MR-Linac into Radiation Therapy Practice Integrating the MR-Linac into Radiation Therapy Practice Mikki Campbell MRT(T), MHE Winnie Li MRT(T), MSc UTDRO Evening Journal Club MR-Linac: From Prototype to Clinical January 24, 2019 Objectives To

More information

Practical Workflow and the Cost of Adaptive Therapy. Rojano Kashani, Ph.D., DABR Washington University School of Medicine March 7, 2015

Practical Workflow and the Cost of Adaptive Therapy. Rojano Kashani, Ph.D., DABR Washington University School of Medicine March 7, 2015 Practical Workflow and the Cost of Adaptive Therapy Rojano Kashani, Ph.D., DABR Washington University School of Medicine March 7, 2015 Disclosures Travel expenses paid by ViewRay Inc. for on-site software

More information

Controlli di qualità in SBRT

Controlli di qualità in SBRT Controlli di qualità in SBRT Carmelo Marino 24/25 OTTOBRE 2014 Università degli studi di Milano Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors

More information

MR Guided Radiation Therapy: ViewRay System Sasa Mutic, Ph.D.

MR Guided Radiation Therapy: ViewRay System Sasa Mutic, Ph.D. MR Guided Radiation Therapy: ViewRay System Sasa Mutic, Ph.D. Conflict of Interest Statement Shareholder - ViewRay Inc. Clinical advisory board - ViewRay Inc. Research and service - ViewRay Inc. Learning

More information

Learning Objectives. New Technology Reimbursement. Understand the process for CPT applications. Najeeb Mohideen, MD

Learning Objectives. New Technology Reimbursement. Understand the process for CPT applications. Najeeb Mohideen, MD New Technology Reimbursement Najeeb Mohideen, MD Co Chair Health Policy Committee ASTRO Department of Radiation Oncology, Northwest Community Hospital, Arlington Heights, IL Learning Objectives Understand

More information

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident Resident s Name: RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident Rotation: PHYS 705: Clinical Rotation 3 Inclusive dates of rotation: Aug. 25, 2015 Feb. 25, 2016 Director or Associate

More information

Disclosures I have provided Physics Consultation Services to Varian and Vision RT

Disclosures I have provided Physics Consultation Services to Varian and Vision RT Surface Imaging to Inform Statistical Quality Control for SRS Treatments Michael J Tallhamer M.Sc. DABR Chief of Radiation Physics Centura Health MichaelTallhamer@Centura.org Quality Improvement and Safety

More information

SunCHECK * it. *2.0: INDEPENDENT QA. YOUR WAY.

SunCHECK * it. *2.0: INDEPENDENT QA. YOUR WAY. SunCHECK * it. *2.0: INDEPENDENT QA. YOUR WAY. SunCHECK it. // 2.0: INDEPENDENT QA. YOUR WAY. Integrated. Independent. Radiation Oncology departments are busy. In pursuit of Patient Safety, Medical Physicists

More information

Benchmark & FAQ for NRG BR001: A Phase 1 Study of SBRT for the Treatment of Multiple Metastases

Benchmark & FAQ for NRG BR001: A Phase 1 Study of SBRT for the Treatment of Multiple Metastases Benchmark & FAQ for NRG BR001: A Phase 1 Study of SBRT for the Treatment of Multiple Metastases Credentialing Requirements (SECTION 5) Facility Questionnaire Benchmark planning 3DCRT credentialing IMRT

More information

Vendor Tools and Uses for TG-142

Vendor Tools and Uses for TG-142 Vendor Tools and Uses for TG-142 Bret H. Heintz, PhD, DABR Regional Director Medical Physics Texas Oncology March 8, 2015 Disclaimer No financial relationships to disclose with any of the companies discussed

More information

VMAT monthly QA using two techniques: 2D ion chamber array with an isocentric gantry mount and an in vivo dosimetric device attached to gantry

VMAT monthly QA using two techniques: 2D ion chamber array with an isocentric gantry mount and an in vivo dosimetric device attached to gantry Journal of Radiotherapy in Practice Journal of Radiotherapy in Practice (2013) Page 1 of 7 & Cambridge University Press 2013 doi:10.1017/s1460396912000556 Technical Note VMAT monthly QA using two techniques:

More information

Proton Treatment Planning Systems Daniel Yeung

Proton Treatment Planning Systems Daniel Yeung New Developments in Proton Treatment Planning Systems Daniel Yeung Statement of Disclosure Funded Research & Development: Philips Medical Systems IBA Proton Planning Systems Commercial Systems Academic

More information

Eric E. Klein, Ph.D. Chair of TG-142

Eric E. Klein, Ph.D. Chair of TG-142 Eric E. Klein, Ph.D. Chair of TG-142 Professor of Radiation Oncology Washington University St. Louis, MO 04 October, 2010 NE AAPM Chapter American Association of Physicists in Medicine Establishes standards

More information

Reducing VMAT Patient Specific Machine The Christie

Reducing VMAT Patient Specific Machine The Christie Reducing VMAT Patient Specific Machine Verification @ The Christie Phil Whitehurst Christie Medical Physics & Engineering Wilmslow Road Manchester M20 4BX Background Outline Christie IMRT/VMAT Techniques

More information

Evaluation of Dynamic Conformal Arc Therapy for Treatment of Lung and Liver

Evaluation of Dynamic Conformal Arc Therapy for Treatment of Lung and Liver Evaluation of Dynamic Conformal Arc Therapy for Treatment of Lung and Liver Sotiri Stathakis, PhD, DABR Disclosure ELEKTA Monaco research support I do not have a financial interest in any company or product

More information

AQUA. Data-backed Assurance

AQUA. Data-backed Assurance AQUA Data-backed Assurance Departmental machine quality management As radiation therapy technology becomes more sophisticated and treatments increasingly complex, there is a growing quality assurance burden

More information

Imaging for Proton Treatment Planning and Verification

Imaging for Proton Treatment Planning and Verification Imaging for Proton Treatment Planning and Verification Jon J. Kruse Mayo Clinic Dept. of Radiation Oncology Rochester, MN Acknowledgements T.J. Whitaker; Mayo Clinic John Mullins; Mayo Clinic Hiroki Shirato,

More information

Clinical feasibility of dual tube floor based kilo voltage X-ray localization system for image guided radiation therapy

Clinical feasibility of dual tube floor based kilo voltage X-ray localization system for image guided radiation therapy 2018; 4(3): 384-391 ISSN Print: 2394-7500 ISSN Online: 2394-5869 Impact Factor: 5.2 IJAR 2018; 4(3): 384-391 www.allresearchjournal.com Received: 26-01-2018 Accepted: 27-02-2018 Suresh Rao Department of

More information

CODING GUIDELINES. Radiation Therapy. Effective January 1, 2018

CODING GUIDELINES. Radiation Therapy. Effective January 1, 2018 CODING GUIDELINES Radiation Therapy Effective January 1, 2018 Coding guidelines for medical necessity review of radiation therapy services. 2018 evicore healthcare. All rights reserved. Please note the

More information

Clinical Evaluation of real-time, patient-centric QA using the Delta 4 Discover

Clinical Evaluation of real-time, patient-centric QA using the Delta 4 Discover Clinical Evaluation of real-time, patient-centric QA using the Delta 4 Discover Karl H Rasmussen, Ph.D.. khrasmussen@uthscsa.edu Nema Bassiri bassirin@livemail.uthscsa.edu Division of Medical Physics Cancer

More information

IMAGE GUIDANCE DOSES IN RADIOTHERAPY. Scott Crowe

IMAGE GUIDANCE DOSES IN RADIOTHERAPY. Scott Crowe IMAGE GUIDANCE DOSES IN RADIOTHERAPY Scott Crowe IMAGING DOSE ALARA requires that imaging dose is managed and optimised Imaging dose presents an increased risk for paediatric patients Increased effective

More information

ARIA Oncology Information System for Radiation Oncology User-focused Advantages

ARIA Oncology Information System for Radiation Oncology User-focused Advantages ARIA Oncology Information System for Radiation Oncology User-focused Advantages For Oncologists: Prescription linking ability Gated treatment interface Unified workspace interfaces for imaging HDR integration

More information

ESTRO recommended event. ESMPE European School for Medical Physics Experts Prague January Imaging in Radiotherapy

ESTRO recommended event. ESMPE European School for Medical Physics Experts Prague January Imaging in Radiotherapy ESTRO recommended event ESMPE European School for Medical Physics Experts Prague January Imaging in Radiotherapy January 26 January 28, Prague, Czech Republic The EFOMP in collaboration with the Czech

More information

Experience and Suggestions on Commissioning and QA Procedures for Halcyon Version 1.2

Experience and Suggestions on Commissioning and QA Procedures for Halcyon Version 1.2 Experience and Suggestions on Commissioning and QA Procedures for Halcyon Version 1.2 Contributors: MD Anderson Cancer Center University of Pennsylvania Laurence Court Dimitris Mihailidis Peter Balter

More information

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies A WRITTEN DIRECTIVE SURROGATE FOR PHYSICIAN REAL-TIME IGRT APPROVAL

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies A WRITTEN DIRECTIVE SURROGATE FOR PHYSICIAN REAL-TIME IGRT APPROVAL 1 UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies A WRITTEN DIRECTIVE SURROGATE FOR PHYSICIAN REAL-TIME IGRT APPROVAL A Research Project Report Submitted in Partial Fulfillment of the Requirements for

More information

Commissioning of the Heidelberg Ion Beam Therapy Centre

Commissioning of the Heidelberg Ion Beam Therapy Centre Commissioning of the Heidelberg Ion Beam Therapy Centre Jacksonville, May 2008 O. Jäkel 1,2, M. Ellerbrock 1, P. Heeg 1, B. Ackermann 1, M. Winter 1, K. Parodi 1, S. Brons 1, A. Mairani 1,2, T. Haberer

More information

MRI-Guided On-line Adaptive Radiotherapy The UCLA Physics Experience. Disclosures 8/3/2016

MRI-Guided On-line Adaptive Radiotherapy The UCLA Physics Experience. Disclosures 8/3/2016 MRI-Guided On-line Adaptive Radiotherapy The UCLA Physics Experience James Lamb, Nzhde Agazaryan, Minsong Cao, Mitch Kamrava, Percy Lee, Daniel Low, David Thomas, Yingli Yang Department of Radiation Oncology

More information

RADIATION SAFETY ISSUES LINKED TO THE OMNIPRESENCE OF COMPUTERS

RADIATION SAFETY ISSUES LINKED TO THE OMNIPRESENCE OF COMPUTERS RADIATION SAFETY ISSUES LINKED TO THE OMNIPRESENCE OF COMPUTERS Jean-Claude ROSENWALD Institut Curie, Paris Consultant DOSIsoft Earlier use of computers in radiotherapy 1950 1960 : replacement of tedious

More information

Status of ART in the Clinic

Status of ART in the Clinic Status of ART in the Clinic Adaptive Radiotherapy for HN Cancer: Technical Aspects Di Yan, D.Sc, FAAPM Beaumont Health System Michigan, USA Learning Objectives Clinical rationales of ART for HN caner ART

More information

Part 3 Oral Exam Content Guide

Part 3 Oral Exam Content Guide Initial Certification in Medical Physics Part 3 Oral Exam Content Guide The oral examination is designed to test your knowledge and fitness to practice applied medical physics in the specified specialty(ies).

More information

Michael Gillin, PhD Professor, Chief of Clinical Services, Dept. of Radiation Physics

Michael Gillin, PhD Professor, Chief of Clinical Services, Dept. of Radiation Physics Michael Gillin, PhD Professor, Chief of Clinical Services, Dept. of Radiation Physics Michael Gillin - Grandfather My twin 12 month old grandsons, Arthur and Charles, live in Minneapolis. UT MDACC > 8,000

More information

2017 ACR Computed Tomography Quality Control Manual FAQS

2017 ACR Computed Tomography Quality Control Manual FAQS Updated 11-15-2017 2017 ACR Computed Tomography Quality Control Manual FAQS Q. The updated 2017 ACR Computed Tomography Quality Control Manual has been released. (Visit www.acr.org/education/education-catalog.)

More information

ArcCHECK & 3DVH. The Ultimate 4D Patient QA Solution. Your Most Valuable QA and Dosimetry Tools

ArcCHECK & 3DVH. The Ultimate 4D Patient QA Solution. Your Most Valuable QA and Dosimetry Tools ArcCHECK & 3DVH The Ultimate 4D Patient QA Solution Your Most Valuable QA and Dosimetry Tools THE 4D QA GOLD STANDARD The ArcCHECK is the world s most selected independent 4D measurement array. Simply

More information

7/22/2014. The Necessity of Innovation in Medical Physics. Disclosures. AAPM - Medical Physicists. John Bayouth, Ph.D.

7/22/2014. The Necessity of Innovation in Medical Physics. Disclosures. AAPM - Medical Physicists. John Bayouth, Ph.D. The Necessity of Innovation in Medical Physics John Bayouth, Ph.D. President, AAPM Professor and Chief of Physics Department of Human Oncology University of Wisconsin Disclosures Principal employer: University

More information

Computational Verification in Interventional Radiation Oncology (Brachytherapy)

Computational Verification in Interventional Radiation Oncology (Brachytherapy) Computational Verification in Interventional Radiation Oncology (Brachytherapy) Prof. Dr. Dimos Baltas Abteilung Medizinische Physik & Engineering Strahlenklinik Brussels, 5- December- 2014 Starkenburgring

More information

N.MAFFEI, G.GUIDI, C.VECCHI, G.BALDAZZI Physics Department, University of Bologna, via Irnerio Bologna, Italy

N.MAFFEI, G.GUIDI, C.VECCHI, G.BALDAZZI Physics Department, University of Bologna, via Irnerio Bologna, Italy AN ARTIFICIAL NEURAL NETWORK TO PREDICT TIME OF REPLANNING FOR TOMOTHERAPY TREATMENTS N.MAFFEI, G.GUIDI, C.VECCHI, G.BALDAZZI Physics Department, University of Bologna, via Irnerio 40 40138 Bologna, Italy

More information

Clinical commissioning and operation of IBA Proteus ONE: the Royal Oak's experience

Clinical commissioning and operation of IBA Proteus ONE: the Royal Oak's experience Clinical commissioning and operation of IBA Proteus ONE: the Royal Oak's experience Xuanfeng (Leo) Ding, Ph.D., DABR Lead Medical Physicist, Proton Beam Therapy Adjunct Professor, Oakland University Sept.

More information

An improvement in IMRT QA results and beam matching in linacs using statistical process control

An improvement in IMRT QA results and beam matching in linacs using statistical process control JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 5, 2014 An improvement in IMRT QA results and beam matching in linacs using statistical process control Justin D. Gagneur a and Gary A. Ezzell

More information

Elekta VMAT. Freedom to Treat. Enhanced dose conformance for patient-specific treatment

Elekta VMAT. Freedom to Treat. Enhanced dose conformance for patient-specific treatment Elekta VMAT Freedom to Treat Enhanced dose conformance for patient-specific treatment Speed or Accuracy Why choose? Clinical data has shown that around 50% of patients would benefit from IMRT treatment

More information

To the Graduate Council:

To the Graduate Council: To the Graduate Council: I am submitting herewith a thesis written by Michelle Lynn Neeley entitled Patient- Specific Quality Assurance for IMRT. I have examined the final electronic copy of this thesis

More information

Real-Time Monitoring of Treatment Delivery. Sonja Dieterich, Ph.D., FAAPM Professor

Real-Time Monitoring of Treatment Delivery. Sonja Dieterich, Ph.D., FAAPM Professor Real-Time Monitoring of Treatment Delivery Sonja Dieterich, Ph.D., FAAPM Professor Disclosures UC Davis has a contract with Sun Nuclear for beta-testing PerFraction Scientific Advisor, MGS Research Patients

More information

Integrated on-board CBCT-US imaging system for soft tissue IGRT and real-time intra-fraction monitoring

Integrated on-board CBCT-US imaging system for soft tissue IGRT and real-time intra-fraction monitoring Integrated on-board CBCT-US imaging system for soft tissue IGRT and real-time intra-fraction monitoring John Wong Radiation Oncology and Molecular Radiation Sciences Johns Hopkins University School of

More information

Introduction to Radiation Therapy : Basics, and Recent Technologies

Introduction to Radiation Therapy : Basics, and Recent Technologies Introduction to Radiation Therapy : Basics, and Recent Technologies Pusan National University Undergraduate Student Seminar Justin. C. Park (Chun Joo Park) Dept. of Electrical and Computer Engineering

More information

Proposal on Guideline for Quality Assurance of Radiation Treatment Planning System

Proposal on Guideline for Quality Assurance of Radiation Treatment Planning System Original Article PMP Progress in Medical Physics 28(4), December 2017 https://doi.org/10.14316/pmp.2017.28.4.197 pissn 2508-4445, eissn 2508-4453 Proposal on Guideline for Quality Assurance of Radiation

More information

03/08/2017. Advances and Challenges in Contour QA for Adaptive RT. Objective. Disclosures

03/08/2017. Advances and Challenges in Contour QA for Adaptive RT. Objective. Disclosures Advances and Challenges in Contour QA for Adaptive RT Kristy K Brock, PhD, DABR, FAAPM Professor, Department of Imaging Physics Director, Image Guided Cancer Therapy Program University of Texas MD Anderson

More information

Measurement Considerations in an MR-guided Radiation Therapy Environment

Measurement Considerations in an MR-guided Radiation Therapy Environment Measurement Considerations in an MR-guided Radiation Therapy Environment John Bayouth, PhD Chief of Physics and Bhudatt Paliwal Professor Department of Human Oncology University of Wisconsin - Madison

More information

7/31/2017. Implementing a Clinical Practice Guideline; Lessons From An Early Adopter of MPPG 5.a. Disclosures

7/31/2017. Implementing a Clinical Practice Guideline; Lessons From An Early Adopter of MPPG 5.a. Disclosures Implementing a Clinical Practice Guideline; Lessons From An Early Adopter of MPPG 5.a Dustin Jacqmin, PhD Assistant Professor, Human Oncology University of Wisconsin Madison None Disclosures 1 Outline

More information

E2E SBRT Thorax Phantom

E2E SBRT Thorax Phantom E2E SBRT Thorax Phantom Model 036A-CVXX-xx SBRT END-TO-END SBRT TESTING SOLUTION SCAN PLAN LOCALIZE TREAT This product is available through: JRT Associates 800-22-0 2428 Almeda Avenue Suite 36 Norfolk,

More information

Pinnacle 3. Treatment Planning. Flexible, intuitive planning environment

Pinnacle 3. Treatment Planning. Flexible, intuitive planning environment Pinnacle 3 Treatment Planning Flexible, intuitive planning environment Pinnacle 3 Flexible, intuitive planning environment Planning plays a central role in influencing treatment confidence as well as departmental

More information

Pinnacle 3. Treatment Planning. Flexible, intuitive planning environment

Pinnacle 3. Treatment Planning. Flexible, intuitive planning environment Pinnacle 3 Treatment Planning Flexible, intuitive planning environment Pinnacle 3 Flexible, intuitive planning environment Planning plays a central role in influencing treatment confidence as well as departmental

More information

Initial Certification

Initial Certification Initial Certification Therapeutic Medical Physics (TMP) Content Guide Part 2 Content Guide and Sample Questions PLEASE NOTE: List of Constants and Physical Values for Use on the Part 2 Physics Exams The

More information

DESIGN OF AN ANTHROPOMORPHIC INTENSITY MODULATED RADIATION THERAPY QUALITY ASSURANCE PHANTOM

DESIGN OF AN ANTHROPOMORPHIC INTENSITY MODULATED RADIATION THERAPY QUALITY ASSURANCE PHANTOM DESIGN OF AN ANTHROPOMORPHIC INTENSITY MODULATED RADIATION THERAPY QUALITY ASSURANCE PHANTOM Dee-Ann Radford, David S. Followill, Peter A. Balter, William F. Hanson Department of Radiation Physics The

More information

SPECIFICATION CT SIMULATOR FOR BLACK LION HOSPITAL, ADDIS ABEBA, ETHIOPIA

SPECIFICATION CT SIMULATOR FOR BLACK LION HOSPITAL, ADDIS ABEBA, ETHIOPIA SPECIFICATION CT SIMULATOR FOR BLACK LION HOSPITAL, ADDIS ABEBA, ETHIOPIA 1. Scope This specification describes the requirements for the supply, delivery, installation, and acceptance testing of a CT Simulator

More information

Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, UK

Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, UK A megavoltage scatter correction technique for cone-beam CT images acquired during VMAT delivery C. J. Boylan 1,2, T. E. Marchant 1,2, J. Stratford 3, J. Malik 4, A. Choudhury 4, R. Shrimali 4, J. Rodgers

More information

Proton Therapy Workflow Martijn Engelsman HollandPTC and TU Delft

Proton Therapy Workflow Martijn Engelsman HollandPTC and TU Delft Proton Therapy Workflow Martijn Engelsman HollandPTC and TU Delft Disclaimer: I have no financial interest in any vendor of radiotherapy hardware, software, or otherwise PSI Winterschool, January 2012

More information

Accelerated IMRT and VMAT planning

Accelerated IMRT and VMAT planning Pinnacle 3 Auto-Planning Accelerated IMRT and VMAT planning Philips Pinnacle 3 Auto-Planning specifications Pinnacle 3 Auto-Planning is designed to simplify and accelerate IMRT & VMAT planning. It has

More information

Shielding evaluation for IMRT implementation in an existing accelerator vault

Shielding evaluation for IMRT implementation in an existing accelerator vault JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 4, NUMBER 3, SUMMER 2003 Shielding evaluation for IMRT implementation in an existing accelerator vault R. A. Price,* O. Chibani, and C.-M. Ma Department

More information

Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS

Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS PRODUCT SOLUTIONS // Table of Contents Contents Better Outcomes Through Technology...5 Innovation That Improves Outcomes While Saving Time...6

More information

I M A G E G U I D E D R A D I A T I O N T H E R A P Y. Elekta XVI. Inspiring clinical confidence

I M A G E G U I D E D R A D I A T I O N T H E R A P Y. Elekta XVI. Inspiring clinical confidence I M A G E G U I D E D R A D I A T I O N T H E R A P Y Elekta XVI Inspiring clinical confidence 1 New levels of precision and accuracy Tumor target motion is a significant factor in inhibiting increasing

More information

Process Mapping. Acknowledgements 7/21/2014. Disclosures

Process Mapping. Acknowledgements 7/21/2014. Disclosures Process Mapping Jatinder R Palta, PhD, FAAPM, FASTRO Professor and Chair Medical Physics, VCU Chief Physicist, VHA Radiation Oncology Richmond, Virginia Acknowledgements Derek Brown, PhD University of

More information

Here is a sample chapter from A Primer on Theory and Operation of Linear Accelerators in Radiation Therapy. A Primer on

Here is a sample chapter from A Primer on Theory and Operation of Linear Accelerators in Radiation Therapy. A Primer on A Primer on Theory and Operation of Linear Accelerators in Radiation Therapy THIRD EDITION C. J. Karzmark and Robert J. Morton James Lamb, Editor MEDICAL PHYSICS PUBLISHING Here is a sample chapter from

More information

BodyFIX Maximize positional accuracy. Support delivery with precise patient positioning and immobilization

BodyFIX Maximize positional accuracy. Support delivery with precise patient positioning and immobilization BodyFIX Maximize positional accuracy Support delivery with precise patient positioning and immobilization BodyFIX Simple and flexible immobilization High conformance radiation therapy treatment modalities

More information

Connect and Deliver Optima CT580 RT

Connect and Deliver Optima CT580 RT GE Healthcare Connect and Deliver Optima CT580 RT Taking aim at cancer requires more than skill and compassion it takes the right connections. Radiation oncologists must connect with a CT simulator that

More information

Maintenance, Logistics and Cost-effectiveness of Proton Therapy Centers

Maintenance, Logistics and Cost-effectiveness of Proton Therapy Centers Maintenance, Logistics and Cost-effectiveness of Proton Therapy Centers Niek Schreuder ProCure Treatment Centers PTCOG 47 Educational Session May 2008 Jacksonville, Florida Learning Objectives 1. Understand

More information

REF # DOC #80XXX-00. STANDARD IMAGING, INC Deming Way Middleton, WI TEL TEL FAX

REF # DOC #80XXX-00. STANDARD IMAGING, INC Deming Way Middleton, WI TEL TEL FAX WWW..COM REF 91240 STANDARD IMAGING, INC. 3120 Deming Way Middleton, WI 53562-1461 TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 Aug / 2011 2011 Standard Imaging, Inc. DOC #80XXX-00 #80109-02 General

More information

EURATOM Booklet. Ready for February 6th 2018?

EURATOM Booklet. Ready for February 6th 2018? EURATOM Booklet Ready for February 6th 2018? February 6 th 2018 will see the introduction of the new EURATOM directive 201/59/. This is the deadline when you must have the necessary framework in place

More information

Strategies for Adaptive RT

Strategies for Adaptive RT Strategies for Adaptive RT Olga L. Green Disclosures Honoraria and travel grants from ViewRay, Inc. 1 Learning Objectives What is ART? What is needed to implement real-time, online ART in the clinic? Example

More information

MV Cone Beam CT Imaging for daily localiza6on: (part II)

MV Cone Beam CT Imaging for daily localiza6on: (part II) MV Cone Beam CT Imaging for daily localiza6on: (part II) Jean Pouliot, Ph.D. Professor UCSF Helen Diller Family Comprehensive Cancer Center AAPM CE-Therapy Series Panel Session 7h30-9h25 am, July 28th,

More information

2018 Fall Meeting November 8, 2018 ~ 4:00 8:00

2018 Fall Meeting November 8, 2018 ~ 4:00 8:00 Danielle Lack Stephen Gardner Michael Huberts Choonik Lee Chadd Smith President President-Elect Treasurer Secretary Representative 2018 Fall Meeting November 8, 2018 ~ 4:00 8:00 University of Michigan

More information

The application of error reduction QA philosophy in HDR brachytherapy

The application of error reduction QA philosophy in HDR brachytherapy The application of error reduction QA philosophy in HDR brachytherapy Bruce Thomadsen University of Wisconsin - Madison Learning Objectives Learning objectives: To understand 1. The problem with the current

More information

8/17/2011. Implementation and Quality Assurance Considerations for Volumetric Modulated Arc Therapy (VMAT)*

8/17/2011. Implementation and Quality Assurance Considerations for Volumetric Modulated Arc Therapy (VMAT)* and Quality Assurance Considerations for Volumetric Modulated Arc Therapy * What is? Report of writing group from TETAWG under Therapy Physics Committee (TPC) of AAPM Writing Group members: James M. Galvin,

More information

AAPM TG-275: Live Demonstration of Chart Checks

AAPM TG-275: Live Demonstration of Chart Checks AAPM TG-275: Live Demonstration of Chart Checks EBRT Plan Review: RayStation and Mosaiq Stephanie Parker, MS, DABR, CSSGB Conflicts of Interest unone Systems Acknowledgements ucurtis Whiddon, Ph.D. ushiva

More information

Analisi della letteratura

Analisi della letteratura Scientific writing in Fisica Medica Organizzatore: prof. A. Lascialfari Analisi della letteratura pietro.mancosu@humanitas.it Fake news Fake news Index Fake news Introduction Searching with PubMed Journals

More information

Rishabh Kapoor Jatinder R. Palta Daniel Yeung Anh Le University of Florida

Rishabh Kapoor Jatinder R. Palta Daniel Yeung Anh Le University of Florida Rishabh Kapoor Jatinder R. Palta Daniel Yeung Anh Le University of Florida Improve the connectivity of various radiation oncology hardware and software products Improve radiation oncology work flow Help

More information

Development of quality control standards for radiation therapy equipment in Canada

Development of quality control standards for radiation therapy equipment in Canada JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 8, NUMBER 1, WINTER 2007 Development of quality control standards for radiation therapy equipment in Canada Peter Dunscombe, 1,a Harry Johnson, 2 Clement

More information

Proton Therapy: Application and Quality Assurance

Proton Therapy: Application and Quality Assurance Proton Therapy: Application and Quality Assurance IMRT IMPT Tony Lomax Centre for Proton Radiotherapy, Paul Scherrer Institute, Switzerland Treatment delivery 1. Basics 2. Passive scattering 3. Active

More information

Medical Physics and the Evolving Administrative Role

Medical Physics and the Evolving Administrative Role Medical Physics and the Evolving Administrative Role Michael Howard, PhD DABMP Director Sarah Cannon Cancer Center Chief of Medical Physics AAPM Spring Clinical Meeting 2015 Overview The role of the medical

More information