Interstate 35 West. Lot 2. 1 Mile Population: 4,100 Median HH Income: $53, Mile Population: 47,800 Median HH Income: $56,100
|
|
- Rosaline Ferguson
- 5 years ago
- Views:
Transcription
1 Walmart Outparcels For Sale Burleson, TX Store # rth Burleson Boulevard McCall Street Interstate 35 West Lot 2 Lot 3 State Highway 174 For more information about this site, contact: Hank Wright SRS Real Estate P Hank.wright@srsre.com Other sites available at Lot 2: ±1.29 Acres - $625,000 Lot 3: ±3.42 Acres (±2.6 Acres Usable) - $650,000 Demographic Summary 1 Mile Population: 4,100 Median HH Income: $53,200 3 Mile Population: 47,800 Median HH Income: $56,100 5 Mile Population: 82,900 Median HH Income: $55,900 The information above has been obtained from sources believed reliable. While we do not doubt its accuracy, we have not verified it and make no guarantee, warranty or representation about it. It is your responsibility to independently confirm its accuracy and completeness.
2 Scale: Designed by: Drawn by: Checked by: Date: Project. SHEET AS SHOWN STW KKB KSG APRIL LEGEND W SS FOR REVIEW ONLY Engineer KEVIN S. GASKEY P.E Date 04/02/ OVERALL SITE PLAN STORE # LCR-136-TL INTERSTATE HIGHWAY 35 BURLESON, TEXAS OHE UGT DIG TESS DIG-TESS (@ least 72 hours prior to digging) PROPERTY LINE BUILDING SETBACK LINE PROPOSED EASEMENT FIRE LANE SCREENING WALL RETAINING WALL SIDEWALK TYPE "B" INTEGRAL CONCRETE CURB CART CORRAL PARKING SPACES SYSL / 4" PROPOSED STORM DRAINAGE LINE EXISTING WATER LINE EXISTING SEWER LINE EXISTING STORM SEWER LINE EXISTING OVERHEAD ELECTRIC LINE EXISTING UNDERGROUND TELEPHONE LINE EXISTING UNDERGROUND ELECTRIC LINE ARCHITECTURAL APRON HEAVY DUTY CONCRETE PROPOSED SITE ANALYSIS PARKING SAM'S CLUB ACCESSIBLE UGE CART CORRALS* 538 SPACES 138,445 S.F. 16 SPACES 23 SPACES TOTAL PARKING 554 SPACES * RATIO 4.00/1,000 S.F. SAM'S CLUB AREA AC. TOTAL LAND AREA AC. * PARKING RATIO DOES NOT INCLUDE CART CORRAL SPACES. * CITY OF BURLESON REQUIRES 462 PARKING SPACES. C-03
3 Engineer P.E.. FOR REVIEW ONLY Date A B 2012 C UNLESS SPECIFICALLY INDICATED OTHERWISE IN THE DRAWINGS AND/OR SPECIFICATIONS, THE LIMITS OF THIS SUBSURFACE PREPARATION ARE CONSIDERED TO BE THAT PORTION OF THE SITE DIRECTLY BENEATH AND 5 FEET BEYOND THE BUILDING AND APPURTENANCES. APPURTENANCES ARE THOSE ITEMS ATTACHED TO THE BUILDING PROPER (REFER TO DRAWING SHEET SP1), TYPICALLY INCLUDING, BUT NOT LIMITED TO, THE BUILDING SIDEWALKS, PORCHES, RAMPS, STOOPS, TRUCK WELLS/DOCKS, COMPACTOR PAD, MONUMENT SIGN, PLANTERS, BALE AND PALLET AREA,ETC. THE BASE, WHERE REQUIRED, DOES NOT EXTEND BEYOND THE LIMITS OF THE ACTUAL BUILDING AND THE APPURTENANCES. ESTABLISH THE FINAL SUBGRADE ELEVATION TO ALLOW FOR THE CONCRETE SLAB AND BASE. REFERENCE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR REQUIRED SLAB THICKNESS. THE 6-INCH THICK BASE MATERIAL SHALL CONFORM TO TEXAS DOT STANDARD SPECIFICATIONS FOR CONSTRUCTION, SECTION 247 FLEXIBLE BASE, GRADE 1 WITH MINIMUM 88% RETAINED ON 200 SIEVE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ACCURATE MEASUREMENTS FOR ALL CUT AND FILL DEPTHS REQUIRED. ANY PROPOSED EQUIVALENT ALTERNATIVE BASE MATERIAL MUST BE SUBMITTED FOR APPROVAL WITHIN 30 DAYS AFTER AWARD OF CONTRACT. ANY EQUIVALENT ALTERNATIVE SHALL ONLY BE USED IF APPROVED IN WRITING BY THE CEC AND AOR. D THE BASE AND SLAB SHALL BE SUPPORTED ON AN ENGINEERED PAD CONSISTING OF A MINIMUM 2 FEET OF NON-EXPANSIVE FILL MATERIAL (SELECT FILL OR FLEXIBLE BASE) OVER EITHER 10 FEET OF MOISTURE CONDITIONED ON-SITE SOIL OR TO THE TOP OF SHALY LIMESTONE, WHICH EVER OCCURS FIRST. THE THICKNESS OF NON-EXPANSIVE FILL SHALL BE FEET IN AREAS THAT DO NOT INCLUDE THE BASE (UNDER APPURTENANCES AND OUTSIDE THE BUILDING PERIMETER). NON-EXPANSIVE FILL MATERIAL SHALL NOT EXTEND BEYOND 5 FEET OF THE BUILDING PERIMETER AND/OR APPURTENANCES. IT IS NOT NECESSARY TO REMOVE LIMESTONE TO INSTALL THE NON-EXPANSIVE FILL AND MOISTURE CONDITIONED ON-SITE SOIL. E THE SELECT FILL SHALL BE NON-EXPANSIVE MATERIAL WITH A LIQUID LIMIT LESS THAN 35 AND A PLASTICITY INDEX BETWEEN 5 AND 15. THE SELECT, NON-EXPANSIVE FILL SHALL BE PLACED IN LOOSE LIFTS NOT EXCEEDING 8 INCHES IN THICKNESS. SELECT, NON-EXPANSIVE FILL SHALL BE COMPACTED TO A MINIMUM OF 98 PERCENT OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698) AT A MOISTURE CONTENT WITHIN 1 PERCENTAGE POINT BELOW TO 3 PERCENTAGE POINTS ABOVE OPTIMUM. (NOTE: THE PLASTICITY INDEX AND LIQUID LIMIT OF MATERIAL USED AS SELECT, NON-EXPANSIVE FILL SHALL BE VERIFIED DURING FILL PLACEMENT USING LABORATORY TESTS. VISUAL OBSERVATION AND CLASSIFICATION SHALL NOT BE RELIED UPON TO CONFIRM THE MATERIAL TO BE USED AS SELECT, NON-EXPANSIVE FILL SATISFIES THE ABOVE ATTERBERG-LIMIT CRITERIA.). ATTERBERG-LIMITS TESTS TO VERIFY THE SELECT, NON-EXPANSIVE FILL SHALL BE PERFORMED AT A FREQUENCY OF AT LEAST ONE TEST PER EVERY 2 FT (THICK) PER EVERY 5,000 SQ FT. ATTERBERG-LIMIT TESTS SHALL BE STAGGERED BETWEEN VARIOUS LIFTS WITHIN EACH 5,000 SQ FT. KEVIN S. GASKEY /02/2013 F G FLEXIBLE BASE USED AS NON-EXPANSIVE MATERIAL SHALL CONSIST OF TXDOT STANDARD SPECIFICATIONS ITEM 247, TYPE A OR D, GRADE 1 OR 2. THE FLEXIBLE BASE NON-EXPANSIVE FILL SHALL BE PLACED IN LOOSE LIFTS NOT EXCEEDING 8 INCHES IN THICKNESS. THE MATERIAL SHALL BE COMPACTED TO A MINIMUM 98 PERCENT OF STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698) AND WITHIN 3 PERCENTAGE POINTS OF THE MATERIAL'S OPTIMUM MOISTURE CONTENT. ON-SITE SOIL THAT IS MOISTURE-CONDITIONED BELOW THE SELECT FILL SHALL BE PLACED IN LOOSE LIFTS NOT EXCEEDING 8 INCHES IN THICKNESS. MOISTURE-CONDITIONED SOIL SHALL BE COMPACTED TO 93 TO 97 PERCENT OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698) AT A MOISTURE CONTENT OF AT LEAST 5 PERCENTAGE POINTS ABOVE OPTIMUM. FREE SWELL OF THE IMPROVED MATERIAL SHALL BE VERIFIED AT A FREQUENCY OF AT LEAST ONE SWELL TEST PER EVERY 3 FT (THICK) PER EVERY 5,000 SQ FT. EXISTING FOUNDATIONS, SLABS, PAVEMENTS, AND BELOW-GRADE STRUCTURES SHALL BE REMOVED FROM THE BUILDING AREA. REMOVE SURFACE VEGETATION, TOPSOIL, ROOT SYSTEMS, ORGANIC MATERIAL, EXISTING FILL, AND SOFT OR OTHERWISE UNSUITABLE MATERIAL FROM THE BUILDING AREA. PROOFROLL EXPOSED SOIL SUBGRADE. REMOVE AND REPLACE UNSUITABLE AREAS WITH SUITABLE MATERIAL. SUBGRADE MATERIAL SHALL BE FREE OF ORGANIC AND OTHER DELETERIOUS MATERIALS AND SHALL MEET THE FOLLOWING REQUIREMENTS: LOCATION WITH RESPECT TO FINAL GRADE P.I. L.L. BUILDING AREA, BASE 12 MAX 35 MAX BUILDING AREA, SELECT FILL, BASE TO 2 FT 15 MAX 35 MAX BUILDING AREA, BELOW 2 FT: MOISUTRE CONDITIONED SITE SOILS STORE # LCR-136-TL INTERSTATE HIGHWAY 35 BURLESON, TEXAS THE FOUNDATION SYSTEM SHALL BE DRILLED, STRAIGHT SHAFT PIERS. H THIS FOUNDATION SUBSURFACE PREPARATION DOES NOT CONSTITUTE A COMPLETE SITE WORK SPECIFICATION. IN CASE OF CONFLICT, INFORMATION COVERED IN THIS PREPARATION SHALL TAKE PRECEDENCE OVER THE WALMART SPECIFICATIONS. REFER TO THE SPECIFICATIONS FOR SPECIFIC INFORMATION NOT COVERED IN THIS PREPARATION. THIS INFORMATION WAS TAKEN FROM A GEOTECHNICAL REPORT PREPARED BY ALPHA TESTING, INC., (ALPHA REPORT G121828) DATED FEBRUARY 5, 2013 (GEOTECHNICAL REPORT IS FOR INFORMATION ONLY AND IS NOT A CONSTRUCTION SPECIFICATION). GEOTECHNICAL ENGINEER ADDRESS IS - I J K GRADING NOTES 1. CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING UTILITIES SERVING THE STRUCTURE. UTILITIES ARE TO BE REMOVED TO THE RIGHT-OF-WAY. 2. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 3. ALL CUT OR FILL SLOPES SHALL BE 4:1 OR FLATTER UNLESS OTHERWISE NOTED. 4. EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1 FOOT. 5. PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1 FOOT INTERVALS. GRADING PLAN L ALERT TO CONTRACTOR ALL WM GENERAL CONTRACTOR WORK TO BE COMPLETED (EARTHWORK, FINAL UTILITIES, AND FINAL GRADING) BY THE MILESTONE DATE IN PROJECT DOCUMENTS. OUTLOT AREA TO BE KEPT FREE OF JOB TRAILERS AND STORAGE AFTER THE CONTRACT MILESTONE DATE FOR THE OUTLOT. WM GENERAL CONTRACTOR TO PROVIDE CLEAR ACCESS FOR OUTLOT CONTRACTOR TO THE SPECIFIC PARCEL AT ALL TIMES AFTER MILESTONE DATE. PURCHASER OF OUTLOT TO PROVIDE PERMIT DOCUMENTS AND SWPPP REQUIRED BY STATE/LOCAL REQUIREMENTS FOR SPECIFIC OUTLOT. DEWATERING NOTE WHEN PERFORMING GRADING OPERATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. REFER TO MASTER SITE SPECIFICATIONS. BENCHMARKS BM#1 BOX WITH X-CUT ON TOP OF CURB ON EAST SIDE OF I-35W ACCESS ROAD ADJACENT TO NORTHWEST PROPERTY CORNER OF SUBJECT TRACT. ELEVATION. = ' BM#2 BOX WITH X-CUT ON A STONE RETAINING WALL, +/- 400' EAST OF NORTHWEST PROPERTY CORNER OF SUBJECT TRACT 4"+/- NORTH OF NORTH PROPERTY LINE OF SUBJECT TRACT. ELEVATION. = ' BM#3 BOX WITH X-CUT ON TOP OF CURB +/- 175' NORTH OF SOUTHWEST PROPERTY CORNER OF SUBJECT TRACT ON EAST SIDE ACCESS ROAD OF I-35W. ELEVATION = ' LEGEND DIG TESS DIG-TESS (@ least 72 hours prior to digging) 6. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR BETTER. 7. ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING & COVERS. MANHOLES IN UNPAVED ARES SHALL BE 6" ABOVE FINISH GRADE. LIDS SHALL BE LABELED "STORM SEWER". 8. THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE WAL-MART SPECIAL CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION. THIS APPLIES TO WAL-MART BUILT PROJECTS ONLY. 9. CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS GRADE. 10. CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS. 11. TOPOGRAPHIC INFORMATION IS TAKEN FROM A TOPOGRAPHIC SURVEY BY LAND SURVEYORS. IF THE CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE OWNER FOR REVIEW. 12. ALL UNSURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED. 13. CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO SAME. 14. SPOT ELEVATIONS SHOWN ARE TO TOP OF PAVING SURFACE OR FINISHED EARTH GRADE. UNLESS NOTED OTHERWISE. WHERE APPLICABLE ADD 0.50' TO SPOT GRADES SHOWN FOR TOP OF CURB ELEVATIONS. 15. ALL STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT OUT. AS SHOWN Scale: Designed by: STW Drawn by: KKB Checked by: KSG Date: APRIL 2013 Project SHEET C-13
4 Kimley-Horn and Associates, Inc Merit Drive, Suite 1000 Dallas, TX Kevin Gaskey, P.E. (972) (972) Location of Project: Store Type: Size of the Store: Burleson, TX Sam's Club 136 Proto Store #: Date of this Report: Wednesday, May 15, 2013 OUTLOT/EXCESS LAND SETBACKS ZONING Minimum building setbacks for each property Current zoning Size Square Lot # Front Left Side Right Side Back Zoning Lot (in Acres) footage Lot 1Lot AC 50,660 50' 20' 20' 20' Commercial - C Lot 2Lot AC 149,062 50' 20' 20' 20' Commercial - C ZONING 1. Is there an Overlay District, PUD, etc. that impacts the development of the outlot/excess land? 2. If yes, please describe: I-35 Overlay district 3. What Jurisdiction is the property in? City of Burleson 4. Is a restaurant permitted? 5. Is patio seating permitted? 6. Is there a restriction prohibiting a drive thru (restaurant, bank, etc.)? 7. Please add any additional information/comments that impact the outlot/excess land regarding zoning: PARKING REQUIREMENTS: 1. Wal-Mart's required parking ratio: Restaurant 15 / 1,000 Retail 5 / 1,000 Page 1 of 10
5 2. Is the City or County's parking requirement greater than Wal-Mart's If, what is the requirement? Restaurant Retail SIGNAGE: 1. What type of signage is allowed for the outlots per local codes and/or ordinances? 2. If other, please define: Other Pole sign, pylon sign, or monument sign 3. What is the maximum height allowed for the signage? Pole sign: 70 feet, Pylon sign: 70 feet, Monument sign: max 8 feet for single tenant, max 12 feet for multitenant 4. What is the maximum square footage allowed for the signage? Pole sign: 300 SF, Pylon sign: 300 SF, Monument sign: 300 SF for single tenant, 400 SF for multi-tenant 5. Explain how the square footage is calculated: The are of the smallest rectangle enclosing the extreme limits of characters, lettering, illustrations ornamentations, or other rixtures, material or color forming part of the sign. Gross surface area shall be measured on one side only of a two-faced (back to back) sign carrying the same image and message on both faces. Two-faced signs carrying different messages and images shall be considered separate signs. 6. If Other or signage is permitted explain why and give options to change the signage regulations: 7. Is roof signage permitted? 8. What is the maximum size? 30% of the area of the building elevation to which it is attached 9. Are wall logo's and/or signs permitted? 10. Is Neon signage permitted? 11. How long is the variance process for outlot signage and what is required? 12. Describe all reviews, hearings, variances and general requirements known at this time: Page 2 of 10
6 PLATTING 1. Is the property (including the outlots/excess land) required to be platted? 1a. If no please explain: 2. 1b. If yes, has the plat been recorded? 1c. What is the book, page or volume? 1d. What was the date it was recorded? If the property has not been platted, please describe the process including who is responsible for the platting and timeframe for completion. The Final Plat will go to City Council for approval on June 17, **te: If platting is not required, a metes and bounds legal description for each parcel should be forwarded to the respective Wal-Mart Land Development Manager as soon as possible. STREET/HIGHWAY ACCESS AND TRAFFIC STUDY: 1. Who has Jurisdiction on this site? 2. Will the Jurisdiction allow direct access and/or curbcuts to the main street or highway? 3. If there is a concrete median in front of the property, will the Jurisdiction allow it to be cut? 4. Are there any future highway/street improvements anticipated that would impact the outlot/excess land? City of Burleson and TxDOT **te: Wal-Mart does not typically allow purchaser's direct access and/or curbcuts to the main street or highway. Access to the outlot/excess land is granted through the Wal-Mart access drive! 4a. If yes, please describe along with the timeframe and location: The extension of Stone Road (by Freese & Nichols) will be built prior to construction completion of this project. It will be the main access point for Lot 3. Expected completion date: June Are sidewalks required on the outlot/excess land? 5a. If yes, what type and size: Sidewalks along TxDOT facilities shall be 5 feet wide and located 4 feet off the right-of-way line 6. Was a traffic study performed for the overall project? 6a. If yes, was the outlot(s)/excess land included? 6b. What was the estimated traffic count, peak hour trips, total trips, proposed use, etc. for each parcel? Traffic count: 440 AM and 917 PM, Peak Hour Trips: 382 AM and 1090 AM and 997 PM, Total Trips: 1359, Proposed Use: Commercial Retail (All parcels included in provided data) Page 3 of 10
7 6c. Will an additional traffic study be required for each purchaser? 6d. If yes, please explain why and any requirements including applicable timeframes: 6e. Does the traffic study, trips, etc. have an expiration date? 6f. If yes, please provide the expiration date and any other important information: Per City of Burleson requirements UTILITIES: Water 1. Is water stubbed to the outlot(s)? 1a. If not, where is it located? 2. Is water stubbed to the excess land? 2a. If not, where is it located? 3. Who has Jurisdiction of the water line? City of Burleson 4. What is the size of the water main? 12-inch and 8-inch 5. What is the normal pressure? Static Pressure = psig 6. Is there a Tap Fee? 7. Is there a Meter Fee? 8. Can the hose bibs & irrigation be on a separate meter? Select / 9. What is the size of the line required? 8" for commercial 10. Are backflow preventer valves required for fire sprinkler lines? 11. Is the water line located in an existing easement? 12. Is there a current moratorium or a chance for one in the future? Select / 13. Please add any additional information/comments regarding water: Sanitary Sewer 1. Is sanitary sewer stubbed to the outlot(s)? 1a. If not, where is it located? 2. Is sanitary sewer stubbed to the excess land? 2a. If not, where is it located? 3. What is the size of the sewer line? 4. Who has the Jurisdiction of the sanitary sewer line? 6-inch and 8-inch City of Burleson 5. Nearest manhole: Lot 2 Rim El Inv.El.Out Page 4 of 10
8 Lot 3 Rim El Inv.El.Out Page 5 of 10
9 6. Is a grease trap required for a restaurant? 7. Is there a Tap Fee? 8. Are tap fees based on water useage? 9. Is the tap to be made by the city or a local plumber? Plumber 10. Are there any special assessments? 11. Is there a current moratorium or a chance for one in the future? Select / 12. Is the sanitary sewer line located in an existing easement? Select / 13. If sanitary sewer is not available, can a septic system be used? 13a. What type? 13b. Additional Comments: 14. Can the septic field be paved over? 15. Has a percolation test been performed? 15a. When? 15b. What were the results? (1' in 30 minutes is required for a restaurant) 15c. If the test did not meet the above requirements, what are the alternative solutions? **te: Purchaser is responsible to perform their own percolation test on the outlot/excess land if a septic system is required. 16. Please add any additional information/comments regarding sanitary sewer: Storm Sewer: 1. Is storm sewer stubbed to the outlot? 2. Is storm sewer stubbed to the excess land? 3. If not, please explain how the storm sewer drainage will be addressed for each outlot/excess land: Page 6 of 10
10 4. Has Wal-Mart's detention facility been sized to accept the drainage? 5. Is the Wal-Mart detention pond encroaching on or included within the outlot/excess land property line? 6. Who has the Jurisdiction of the storm sewer? 7. What is the size of the storm sewer? 8. What is the depth? 9. What is the tap fee? 10. Are catch basins required? 11. Is the storm sewer located in an existing easement? 12. Please add any additional information/comments regarding storm sewer: City of Burleson 18-inch to 66-inch 4-ft min **te: Purchaser will have to comply fully with any federal, state or local laws, regulations, ordinances, permits or other authorizations or approvals or other requirements relating to storm water discharges or the control or erosion or sediment discharges from construction projects, including but not limited to the Clean Water Act, 33 U.S.C et seq., and the Storm Water General Permit for Discharges associated with Construction Activities (collectively the Storm Water Requirements ) including without limitation preparing a Storm Water Pollution Prevention Plan (if applicable) to avoid negatively impacting any erosion or sediment controls during earth-disturbing activities, if any. Electric 1. Is electric stubbed to the outlot? 1a. If not, where is it located? 2. Is electric stubbed to the excess land? 2a. If not, where is it located? 3. Is it overhead or underground? Overhead 4. What is the voltage? 5. What is the phase? 6. What is the wire? 7. Who has Jurisdiction of the electricity? 8. Is underground service required? 8a. If yes, will the power company bring conduit and wire to the transformer and/or building? ROW / utility easement Oncor Electric Contractor is responsible for conduit, pullstring and pull boxes. Power company will provide wire. 8b. Is there a standard cost per LF for the installation? 8c. Transformer location: 8d. Can the outlot/excess land be serviced with either a pole mounted or pad mounted transformer 9. Is the primary service connected to the existing transformer? 9a. Are there any service charges or connection fees? 9b. What is the cost? Page 7 of 10 Allowance based on usage Select One
11 10. Is the electric located in an existing easement? 11. Please add any additional information/comments regarding electric: Gas 1. Is gas stubbed to the outlot? 1a. If not, where is it located? ROW / easement 2. Is gas stubbed to the excess land? 2a. If not, where is it located? 3. What is the maximum amount available? 4. Who has Jurisdiction of the gas line? Atmos Energy 5. What type of commitment will the gas company give? 6. Will the gas company bring the line to the building? 6a. What is the estimated cost to do so? At developer's expense - cost TBD 6b. What is the size of the gas line? 3" 6c. What is the pressure of the gas line? 6d. What is the BTU/CF rating? 6e. What is the specific gravity? 6f. Is a meter fee required? 7. Is the gas located in an existing easement? 8. Please add any additional information/comments regarding gas: Telephone 1. Is telephone stubbed to the outlot? 1a. If not, where is it located? 2. Is telephone stubbed to the excess land? 2a. If not, where is it located? 3. Is under ground service required? 4. Who is responsible for bringing telephone lines to the building? 5. Is the telephone located in an existing easement? 6. ROW / easement Contractor and AT&T Please add any additional information/comments regarding telephone: Contractor is responsible for conduit, pull string and pull boxes. AT&T will provide line. Page 8 of 10
12 FEES: 1. Are there any unusually expensive fees or assessments relating to the future development of this property? 2. If yes, please describe in detail and attach a schedule if available: BUILDING CODES: 1. What are the building codes by which the architectural plans must comply with on the outlot/excess land? See City of Burleson current guidelines 1a. What is the date they were adopted: 2. What is the building permit fee schedule? 3. Is the outlot/excess land located in a fire zone or district? 4. Are there any special fire department requirements in addition to standard plans? SITE / LANDSCAPING: 1. Is there a landscaping ordinance in place? 2. Is there any special lighting requirements? 2a. If yes, please describe: Fully shielded and full cut off light fixtures are required for: street, sidewalk and path lighting, parking lots, public spaces, billboards, display areas, and building facades, overhangs and canopies. Directional lights may illuminate signs, flagpoles and architectural features so long as they illuminate only the intended specific object and do not shine into neighboring properties. 3. What type of solid waste disposal is permitted? 3a. Compaction: Select / 3b. Bulk pick up: Select / 3c. Front loader: 3d. Side loader: Select / 3e. Rear loader: Select / 3f. Who has the Jurisdiction of solid waste: 3g. Is this adequate for Jurisdiction? Select / 3h. Is a drain required in the trash area? 3i. Are hot and cold water hose bibs required in the trash area? City of Burleson **te: Wal-Mart requires a masonry trash enclosure for compactor, dumpster. Page 9 of 10
13 SOILS / ENVIRONMENTAL: 1. Was the outlot(s) rough graded? 2. Was it compacted to Wal-Mart standard specifications? 3. Was the excess land rough graded, if applicable? 4. Was it compacted to Wal-Mart's specs? 5. Did the Phase 1 Environmental report indicate contamination? 3a. Report prepared by: 3b. Dated: 3c. If yes, was the contamination located in close proximity to or within the outlot/excess land? 3d. If yes, was the contamination remediated as part of the overall project? Kleinfelder 25-Jan-13 Select / Select / 3e. Please provide any additional information/comments regarding the contamination: 6. Is any portion of the outlot/excess land located in a flood plan and/or wetland area? 6a. If yes, please describe: TRAFFIC: 1. Average Daily Traffic: IH 35W NB Ramp vpd IH 35W FR vpd v.p.d. (year) Civil Consultant: Please add any information and/or comments that you can think impact the development and/or title of the outlot/excess land: The purpose of this "Fact Sheet" is to provide general information regarding the subject property. It is the prospective purchaser's obligation to perform the necessary due diligence to insure that the property is capable of meeting the intended use. CONTACTS: The last page should be all local contacts (from your cover sheet) Page 10 of 10
Lot 2. 1 Mile Population: 5,200 Median HH Income: $46, Mile: Population: 35,500 Median HH Income: $49,300
Walmart Outparcels For Sale Morgan City, LA Store #7099 Margurite Street and rth Victor II Blvd N 9th Street Lot 2 Margurite Street Lot 4 Lot 1 Lot 2 Fair Street Lot 1 rth Victor II Boulevard For more
More informationDallas, TX. Walmart Outparcels For Sale. Store #2105 Midway Road and US I-635
Dallas, TX Walmart Outparcels For Sale Store #2105 Midway Road and US I-635 I US 635 Lot 1 Lot 2 Midway Raod Lot 5 Lot 3 For more information about this site, contact: Ryan Tinch Hollis Bloom (214) 265-1555
More informationDallas, TX. Walmart Outparcels For Sale. Store #2105 Midway Road and US I-635
Dallas, TX Walmart Outparcels For Sale Store #2105 Midway Road and US I-635 I US 635 Lot 6 Lot 7 Midway Raod Lot 5 Lot 8 For more information about this site, contact: Lot 5 : Invest. Property: ± 1.31
More informationFor more information about this site, contact: Lot 2: ± -.77 acres - $575, Mile: Population: 10,000 Median HH Income: $40,700
Walmart Outparcel For Sale McAllen, TX Store #6098 800 E. lan Ave. For more information about this site, contact: Lot 2: ± -.77 acres - $575,000 Hank Wright Hollis Bloom (214) 265-1555 hank@hollisbloom.com
More information1 Mile: Population: 1,800 Median HH Income: $46, Mile: Population: 7,900 Median HH Income: $37,200
FM 90/ East Washington Avenue Walmart Outparcels For Sale Navasota, TX Store #293 Highway 6 and FM 90 Hwy 6 Access Ramp/ Feeder Road N Lot 5 Lot 4 Lot 3 For more information about this site, contact: Lot
More informationMURTI 701, LLC ZONING C-2 SIGNAL CONTROL BOX ' EXISTING CONCRETE PAD EXISTING SIDEWALK N/F SJ & SW ENTERPRISES, LLC DB 6004, PG 7
JAMES STREET 50' R/W WIDTH 220.0' DOCK WELL ' 25.0' 11.0' CART STORAGE 18.0' TYP. 64.77' 18.0' 25.0' 18.0' 18.0' 25.0' 18.0' 18.0' 25.0' 18.0' 18.0' 25.0' 18.0' 18.0' 25.0' 18.0' 54.01' 495.26' N. HOUSTON
More informationSITE PLAN NOTES 1. MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED FROM VIEW WITH HEDGE.
SITE PLAN NOTES FLOOD STATEMENT BY 1. MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED FROM VIEW WITH HEDGE. 2. DUMPSTER SCREENING SHALL BE OF SIMILAR COLOR, MATERIAL, AND DESIGN AS THE PRIMARY STRUCTURE.
More informationSECTION UNCLASSIFIED EXCAVATION AND GRADING
SECTION 02210 UNCLASSIFIED EXCAVATION AND GRADING PART 1 GENERAL 1.1 DESCRIPTION Work in this section includes the excavation, undercut excavating, grading, earthwork and compaction required as shown on
More informationSECTION 12 STANDARDS FOR CONSTRUCTION PLANS AND SPECIFICATIONS
SECTION 12 STANDARDS FOR CONSTRUCTION PLANS AND SPECIFICATIONS 12.1 The subdivider shall construct and install the improvements in accordance with the County's Standards for Construction Plans and Specifications
More informationPUBLIC WORKS DEPARTMENT GENERAL NOTES
PUBLIC WORKS DEPARTMENT GENERAL NOTES 1. All construction shall be in strict accordance with the standards of the City of Southlake and governed by the North Central Texas Council of Government's Standard
More informationPLANNED UNIT DEVELOPMENT & PLANNING APPROVAL STAFF REPORT Date: February 7, 2013
PLANNED UNIT DEVELOPMENT & PLANNING APPROVAL STAFF REPORT Date: February 7, 2013 NAME LOCATION MAWSS Shelton Beach Road East side of Shelton Beach Road Extension, 2/10± mile North of Moffett Road CITY
More informationConstruction Documents Checklist
Construction Documents Checklist The following must be completed prior to final approval of site development plans (Construction Documents) by the Town: Final Drainage Report signed by engineer-of-record
More informationCONSTRUCTION PLANS FOR ENTERPRISE RENTAL CAR
CONSTRUCTION PLANS FOR VICINITY MAP (NOT TO SCALE) DEVELOPER/OWNER: CHRISTOPHER SLOVAN ENTERPRISE HOLDINGS, INC. 284 MALLORY STATION RD, SUITE 120 FRANKLIN, TN 37067 PH: 615-309-9621 DAVIDSON CO., TENNESSSEE
More informationTOWN OF MANCHESTER PLANNING AND ZONING COMMISSION Subdivision Application Minimum Submission Requirements
TOWN OF MANCHESTER PLANNING AND ZONING COMMISSION Subdivision Application Minimum Submission Requirements This checklist is to be completed and submitted with all Subdivision Applications. The Town reserves
More informationSECTION SITE GRADING. Part 1 - General Work Included Related Requirements Reference Standards...
SECTION 02210 - SITE GRADING CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement and Payment...
More informationCITY OF TYLER COMMERCIAL BUILDING PERMIT APPLICATION
CITY OF TYLER COMMERCIAL BUILDING PERMIT APPLICATION Application Date: Permit No.. Estimated Cost of Project $ Square Footage # of Stories All projects over $50,000 must be submitted to the Texas Department
More informationSECTION TRENCHING
SECTION 31 23 17 TRENCHING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Excavating trenches for utilities and utility structures. 2. Bedding. 3. Backfilling and compacting to subgrade elevations.
More informationDIVISION 4100 SITEWORK
DIVISION 4100 SITEWORK SECTION 4115 EARTHWORK PART 1 - GENERAL 1.01 SCOPE This section covers the grading and compaction of excavations, embankments, structural foundations, and planted areas. 1.02 REFERENCES
More information1.01 GENERAL. l.02 PIPELINE TRENCH EXCAVATION PIPELINES AND STRUCTURES REVISION: SECTION 1 PAGE : 1-1
1.01 GENERAL A. The Contractor shall perform all excavation, backfilling, grubbing and grading required for construction and installation of pipelines, structures and appurtenances. Excavation shall include
More informationAPPLICATION FOR PUBLIC INFRASTRUCTURE PERMIT
APPLICATION FOR PUBLIC INFRASTRUCTURE PERMIT Engineering Division 550 Landa Street New Braunfels, Texas 78130 (830) 221-4020 1. Subdivision Plat Name: Location Description/ Nearest Intersection: Acreage:
More informationARTICLE 13 SITE PLAN REVIEW
Sections: 13-1 Intent 13-2 Applicability 13-3 Authority 13-4 Filing Fee 13-5 Submission Requirements 13-6 Standard of Review 13-7 Development Standards ARTICLE 13 SITE PLAN REVIEW SECTION 13-1 INTENT 13-101.
More informationJuly 28, 2015 Port St. Lucie, FL #5704 - New Store Overall Perspective 1 DESIGN REPRESENTATION ONLY - NOT FOR CONSTRUCTION The building images shown are a representation of the current design intent only.
More informationSECTION EARTHWORK; EXCAVATION, FILLING AND GRADING. A. Excavating soil and other material for surface improvements.
SECTION 31 20 00 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Excavating soil and other material for surface improvements. B. Excavating soil and other material for drainage basins. C. Placing fill. D. Compaction
More informationSITE PLAN CRITERIA FOR MUNICIPAL SOLID WASTE & RECYCLABLES STORAGE & ENCLOSURE REQUIREMENTS
SITE PLAN CRITERIA FOR MUNICIPAL SOLID WASTE & RECYCLABLES STORAGE & ENCLOSURE REQUIREMENTS April 2009 General Solid Waste and Recycling Service Responsibilities: The City of Denton is the exclusive provider
More informationChapter 3: Permit Procedures and Requirements
Chapter 1: General Provisions 1 1 Short Title 1 2 Jurisdiction 1 3 Amendments and Revisions 1 4 Enforcement Responsibility 1 5 Review Process 1 6 Prior Approval 1 7 Relationship to Other Standards 1 8
More informationB. Base Course: Aggregate layer placed between the subbase course and hot-mix asphalt paving.
SECTION 312000 - EARTH MOVING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Excavating and filling for rough grading the Site. 2. Preparing subgrades for walks, curbs, pavements, and turf and grasses.
More informationPLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: July 11, 2013
PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: July 11, 2013 SUBDIVISION NAME DEVELOPMENT NAME LOCATION Northside LTD/Joint Venture Subdivision, Resubdivision of and Addition to Lot 3A Northside
More information1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS)
1420 Miner Street Des Plaines, IL 60016 P: 847.391.5380 desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS) Five sets of stamped plans and specifications (six sets if food establishment),
More informationZONING CLEARANCE PLAN REVIEW CHECKLIST. Based on the Revised Town of Carefree Zoning Ordinance
ZONING CLEARANCE PLAN REVIEW CHECKLIST Based on the Revised Town of Carefree Zoning Ordinance Date: Applicant: Permit Number: Reviewer: Address: Lot & Subdivision: Zoning District: New SRF: Addn/Remodel:
More informationB. Subsurface data is available from the Owner. Contractor is urged to carefully analyze the site conditions.
SECTION 31 23 33 - TRENCHING, BACKFILLING AND COMPACTION PART 1 - GENERAL 1.1 SCOPE A. This Section specifies the requirements for excavating and backfilling for storm sewer, sanitary sewer, water distribution
More informationTECHNOLOGY CENTER WAREHOUSE ADDITION ADMINISTRATIVE SERVICE CENTER MOORE PUBLIC SCHOOLS 1500 S.E. 4 th Street Moore, Oklahoma
10-2-2017 October 2, 2017 ADDENDUM NO. 1, Project: Owner: Architect: TECHNOLOGY CENTER WAREHOUSE ADDITION ADMINISTRATIVE SERVICE CENTER MOORE PUBLIC SCHOOLS 1500 S.E. 4 th Street Moore, Oklahoma Moore
More informationGRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW
GRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW Chapter 8 Building and Building Regulations, Article XIII Grading and Drainage and Article XV Soil Erosion and Sedimentation
More informationSTANDARD GRADING AND SOIL EROSION & SEDIMENT CONTROL PLAN FOR SINGLE LOT SINGLE FAMILY RESIDENTIAL CONSTRUCTION AND MINOR EARTH DISTURBANCES
DIVISION OF ENGINEERING & CONSTRUCTION MANAGEMENT PLAN REVIEW DEPARTMENT WASHINGTON COUNTY SOIL CONSERVATION DISTRICT 1260 Maryland Avenue, Suite 101 Hagerstown, MD 21740 Telephone: (301) 797-6821, Ext.
More informationCITY OF LA QUINTA GENERAL NOTES GENERAL NOTES
CITY OF LA QUINTA GENERAL NOTES GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE STANDARD PLANS OF THE CITY OF LA QUINTA, THE LATEST EDITION OF THE STANDARD SPECIFICATIONS
More informationB. Borrow: Satisfactory soil imported from off-site for use as fill or backfill.
SECTION 312000- EARTHWORK PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Special Conditions, apply to this Section. 1.2 SUMMARY This Section
More informationSECTION SOILS REPORT
SECTION 02300 SOILS REPORT 1. GENERAL: 1.1 All work included under this heading shall be subject to the General Conditions of the entire operation. This Contractor is required to refer especially thereto.
More informationEXCAVATION, TRENCHING & BACKFILLING..1 The section refers to excavation, trenching, backfilling and all Work pertaining thereto.
CITY OF BRAMPTON LANDSCAPE SPECIFICATIONS SECTION 02315-1 PART 1 GENERAL 1.1 Description of Work.1 The section refers to excavation, trenching, backfilling and all Work pertaining thereto. 1.2 Related
More informationSECTION 13 - EXISTING FACILITIES TABLE OF CONTENTS
SECTION 13 - EXISTING FACILITIES TABLE OF CONTENTS Section Page 13-1 GENERAL... 13.1 13-1.01 Preservation of Property... 13.1 13-1.02 Overloading, Pavement Protection & Repair... 13.1 13-2 REMOVING EXISTING
More informationCONSTRUCTION PLAN CHECKLIST
CONSTRUCTION PLAN CHECKLIST The design engineer is responsible for ensuring that plans submitted for city review are in accordance with this checklist. It is requested that the executed checklist be submitted
More informationAccessory Dwelling Unit Permit Submittal Requirement Checklist (Corte Madera Municipal Code Section 18.31)
PLANNING DEPARTMENT 300 TAMALPAIS DRIVE CORTE MADERA, CA 94925 Accessory Dwelling Unit Permit Submittal Requirement Checklist (Corte Madera Municipal Code Section 18.31) Address of Project Site Definition:
More informationAPPLICATION FOR RIGHT OF WAY PERMIT
City of Danville Department of Engineering & Urban Services APPLICATION FOR RIGHT OF WAY PERMIT PROJECT LOCATION: CONTRACTOR S BUSINESS NAME: CONTRACTOR'S ADDRESS: CONTRACTOR'S PHONE: OWNER S NAME: OWNER
More informationSECTION MECHANICALLY STABILIZED EARTH RETAINING WALLS
SECTION 13100 MECHANICALLY STABILIZED EARTH RETAINING WALLS PART 1 -- GENERAL 1.01 THE REQUIREMENT A. Includes all labor, material, equipment, testing and submittals required to design and complete construction
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 02222 - EXCAVATION, BACKFILL, AND COMPACTION FOR UTILITIES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Excavating trenches for the installation of utilities and stormwater detention facilities. B.
More informationGRADING, FILL, EXCAVATION AND LANDSCAPING 2012 EDITION
CHAPTER 23.105 GRADING, FILL, EXCAVATION AND LANDSCAPING 2012 EDITION Sections 23.105.101 General... 1 23.105.102 Definitions... 1 23.105.103 Permits required... 3 23.105.104 Hazards.... 4 23.105.105 Permit
More informationSITE SPECIFIC GRADING PLAN FOR CONTIGUOUS SINGLE LOT SINGLE FAMILY RESIDENTIAL CONSTRUCTION WITH PREVIOUSLY APPROVED PRELIMINARY PLAT (FORM 2)
WASHINGTON COUNTY DIVISION OF PLAN REVIEW AND PERMITTING 80 West Baltimore Street Hagerstown, Maryland 21740-6003 Telephone: (240) 313-2460 FAX: (240) 313-2461 Hearing Impaired call 7-1-1 for Maryland
More informationNew Commercial Construction Permit
New Commercial Construction Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts,
More informationARTICLE 700 LARGE SCALE DEVELOPMENTS
ARTICLE 700 LARGE SCALE DEVELOPMENTS SEC. 700.1 APPLICABILITY A development plan shall be submitted to the Bentonville Planning Commission for all developments or building construction regardless of zone
More informationPLANNING AND ZONING COMMISSION APPLICATION FOR IMPROVEMENT PLAT APPROVAL
PLANNING AND ZONING COMMISSION APPLICATION FOR IMPROVEMENT PLAT APPROVAL Date Submitted: Project Number: CITY OF ALEXANDRIA 8236 WEST MAIN STREET ALEXANDRIA, KY 41001 (859) 635-4125 FAX (859) 635-4127
More informationTERRADYN CONSULTANTS, LLC
TERRADYN CONSULTANTS, LLC 10/30/17 Civil Engineering - Land Planning - Stormwater Design - Environmental Permitting 1644 Justin Brown, Code Enforcement Officer Town of Falmouth 271 Falmouth Road Falmouth,
More informationCONDITIONS EXISTING EXISTING CONDITIONS SURVEY PROVIDED BY EGAN, FIELD & NOWAK ON FEBRUARY 20, PRELIMINARY - NOT FOR CONSTRUCTION
K:\TWC_LDEV\\ABRA\Maple Grove, \ Design\CAD\PlanSheets\C- CONDITIONS.dwg April 4, 018 - :44pm 40 0 8 CONDITIONS SURVEY PROVIDED EGAN, FIELD & NOWAK ON FEBRUARY 0, 018. LIMITS OF CONSTRUCTION OVERHEAD POWER
More informationDIVISION 31 EARTHWORK 2006 Edition, Published January 1, 2006; Division Revision Date: January 31, 2012
2006 Edition, Published January 1, 2006; Division Revision Date: January 31, 2012 PART FIVE DOCUMENTS FOR SITE AND INFRASTRUCTURE 31 00 00. EARTHWORK 31 10 00. SITE CLEARING.1 STRUCTURE REMOVAL: Include
More informationBUILDING PERMIT CHECKLIST FOR THE TOWN OF GRAND LAKE
BUILDING PERMIT CHECKLIST FOR THE TOWN OF GRAND LAKE Please Note: No construction, including site preparation (grading, excavating, vegetation removal, etc.), will be allowed until a building permit or
More informationCOMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS
COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS BUILDING & SAFETY DIVISION (530) 795-4910 ext. 112 or 117 FAX (530) 795-4935 318 First Street Winters, CA 95694 This is a list of the minimum
More informationCharter Township of Garfield Grand Traverse County
Charter Township of Garfield Grand Traverse County 3848 VETERANS DRIVE TRAVERSE CITY, MICHIGAN 49684 PH: (231) 941-1620 FAX: (231) 941-1588 SPECIAL USE PERMIT APPLICATION APPLICANT INFORMATION Name: Address:
More informationPLANS. All plans shall be submitted on 24 x 36 sheets
PLANS All plans shall be submitted on 24 x 36 sheets PLANS FOR CONSTRUCTION - (STICKY BACKS NOT ACCEPTABLE) Cover Sheet The first sheet of the plan and profile will not be accepted as a cover sheet. The
More informationPLANNED UNIT DEVELOPMENT, PLANNING APPROVAL & SUBDIVISION STAFF REPORT Date: June 4, 2015
PLANNED UNIT DEVELOPMENT, PLANNING APPROVAL & SUBDIVISION STAFF REPORT Date: June 4, 2015 NAME SUBDIVISION NAME CC Williams Plant Subdivision CC Williams Plant Subdivision LOCATION CITY COUNCIL DISTRICT
More informationPlease print or type.
SOIL EROSION AND SEDIMENTATION CONTROL PERMIT APPLICATION 6-18-07 Ann kjjkjkff- ANN ARBOR CHARTER TOWNSHIP 3792 Pontiac Trail, Ann Arbor, Michigan 48105-9656 Phone (734) 663-3418 Website: www.aatwp.org
More information524 Arctic Court Property Development Feasibility Study
Attachment D 524 Arctic Court Property Development Feasibility Study Prepared for the Redevelopment Agency of Salt Lake City November 2015 Prepared by VODA Landscape + Planning www.vodaplan.com TABLE OF
More information20 North Main Alpine, UT (Phone) (Fax) SITE PLAN
Site Plan Instructions New Home Form #1 20 North Main Alpine, UT 84004 801-756-6347 (Phone) 801-756-1189 (Fax) www.alpinecity.org SITE PLAN A detailed site plan, drawn to scale, 1 = 20 min., shall be filed
More informationCommercial Remodel Permit
Commercial Remodel Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts, each
More informationProject Title: Major Site Review (SR16-06) for Ripon Gardens II Commercial
Planning Commission Staff Report Planning Commission Hearing November 14, 2016 Project Title: Major Site Review (SR16-06) for Ripon Gardens II Commercial Request: A request to develop a 15,996 square foot
More informationC ITY OF D ARIEN Community Development Department 1702 Plainfield Road Phone: (630) Fax: (630)
C ITY OF D ARIEN Community Development Department 1702 Plainfield Road Phone: (630) 353-8115 Fax: (630) 852-4709 BUILDING PERMIT INFORMATION PACKET Revised: October 2018 Building Codes: International Residential
More informationC. Foundation stabilization for pipe and utility structures.
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Excavating, backfilling, and compacting for utilities, including pipe, structures, and appurtenances. B. Control of water in trenches. C. Foundation stabilization
More informationENGINEERING DIVISION CONCURRENT PLAN CHECK PROGRAM
ENGINEERING DIVISION CONCURRENT PLAN CHECK PROGRAM Each applicant needs to thoroughly review the conditions of development issued by the Planning Division in the format of a Resolution approving your project
More informationSpecial Land Use Permit Application Planning Division
Special Land Use Permit Application Planning Division Form will not be processed until it is completely filled out. 1. Applicant Name:_ Address: Phone Number: Fax Number: Email address: 3. Applicant s
More informationConditions of the Utility Permit. Effective January 1, 2019
Conditions of the Utility Permit Effective January 1, 2019 General: 1. Work in the public right-of-way and public easement areas are regulated by Sioux Falls City Ordinance Chapter 96, Right-Of-Way Construction
More informationSECTION TRENCHING & BACKFILLING
SECTION 02225 - TRENCHING & BACKFILLING 1.0 GENERAL 1.1 Work included in this Section includes trenching and backfilling for underground pipelines and related structures only. 1.2 Reference Specifications
More informationCity of Roanoke. Commercial Permit Submittal Guidelines
City of Roanoke Commercial Permit Submittal Guidelines These guidelines are for information purposes only. The contractor is obligated to comply with all adopted codes and ordinances BUILDING INSPECTIONS
More informationCITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413
Page: 1 of 5 CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413 COMMERCIAL/RESIDENTIAL UTILITY PLAN COMPLETENESS CHECK LIST Updated
More informationTable Related Arlington County Standards, Specification and Policies
2.1 GENERAL 2.1.1 DESCRIPTION SITE WORK V02000 2.1 GENERAL 2.1.1 Description This standard identifies minimum requirements that shall be met for all site work in the design and construction of elements
More informationSUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT SINGLE-FAMILY/DUPLEX BUILDING PERMIT / GRADING AND EXCAVATION PERMITTING INFORMATION PACKET
SUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT SINGLE-FAMILY/DUPLEX BUILDING PERMIT / GRADING AND EXCAVATION PERMITTING INFORMATION PACKET GENERAL INFORMATION The following information explains how
More informationAPPENDIX B STANDARD CONSTRUCTION DRAWING NOTES
APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES B-1 General Notes: SACWSD Standard Construction Drawing Notes 1. No work shall begin on any water or wastewater construction project until the construction
More informationPROCEDURES MANUAL INFRASTRUCTURE DEVELOPMENT
City of Shepherdsville Shepherdsville, Kentucky June 3, 2013 Table of Contents Page DEFINITIONS... 4 INTRODUCTION... 7 APPLICATION OF TECHNICAL MANUALS... 9 Public Roads... 9 Private Roads, Parking Lots,
More informationWINTERHAVEN PUBLIC SAFETY FACILITY PROJECT
WINTERHAVEN PUBLIC SAFETY FACILITY PROJECT Funded by: California Department of Housing and Community Development (HCD) through its Community Development Block Grant (CDBG) Program and the County of Imperial.
More informationGUSTAVO J. CARBONELL, P.A.
June 10, 2014 Mr. Jaye Epstein Director Planning and Development Services 2600 Hollywood Blvd, Room 315 Hollywood, Florida 33022-9045 RE: Hollywood 3100, LLC 1915 Harrison St. Hollywood, FL 33020 RE: Case
More informationStormwater Management The District exercises regulatory authority for Stormwater Management in the City of Edina.
Permit Application No.: 7-56 Rules: Erosion Control, Stormwater Management Applicant: Edina Public Schools Received:0/7/207 Project: South View Middle School Addition and Bus Parking Complete: /27/207
More informationSECTION ASPHALT PAVING AND SURFACING
SECTION 02500 ASPHALT PAVING AND SURFACING PART 1 - GENERAL 1.01 WORK INCLUDED A. Traffic control as required to divert vehicular and pedestrian traffic around construction. B. Spreading and compacting
More informationMINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE PLANS, LOW IMPACT DEVELOPMENT PLANS, AND WATER EFFICIENT LANDSCAPE PLANS
Planning and Community Preservation Department Public Works Department 232 West Sierra Madre Boulevard Sierra Madre, CA 91024 (626)355-7135 MINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE
More informationCity of Southlake Commercial Submittal Guidelines
City of Southlake Commercial Submittal Guidelines These guidelines are for information purposes only. The contractor is obligated to comply with all adopted codes and ordinances March 2018 Page 1 BUILDING
More informationPLAN CHECK GUIDELINES MULTI-FAMILY/COMMERCIAL
o PUBLIC WORKS DEPARTMENT PLAN CHECK GUIDELINES MULTI-FAMILY/COMMERCIAL CIVIL ENGINEERING AND ARCHITECTURE 1. Offsite Improvements - Civil Engineering drawings may be required to show the following: Replacement
More informationCity of Lorena 107-A S. Frontage Road Lorena, Texas Phone: (254) Fax: (254)
Residential New Home Building Requirements This document is not meant to modify any Federal or State laws or City Ordinances. It is intended to be informative and to be used as a guideline. Where circumstances
More informationOrdinance No Lot Surface Drainage
Ordinance No. 35-2008 - Lot Surface Drainage The Township has adopted a new Lot Surface Drainage Ordinance which amends Chapter 170, Article IX, Subdivision and Site Plan Review by adding a new Section
More informationPART II - SURVEYING AND GRADING CRITERIA
PART II - SURVEYING AND GRADING CRITERIA A. Surveying Procedures 1. Unless a temporary benchmark is approved in advance by the City Engineer, all submitted civil plans, including but not limited to grading,
More informationGRADING PLAN CHECKLIST
Engineering Division 201 North Broadway, Escondido, CA 92025 (760) 839-4651, FAX (760) 839-4597 GRADING PLAN CHECKLIST To: Attn: Date: Project: Address: Plan Check #: Check #: VIA: The attached plans have
More informationBuilding Permit Submittal Requirements
CITY OF MONTE SERENO 18041 Saratoga-Los Gatos Road Monte Sereno, CA 95030 Phone (408) 354-7635 Fax (408) 395-7653 www.cityofmontesereno.org Building Permit Submittal Requirements NOTE: Submit three (3)
More informationT a b l e o f C o n t e n t s
C i t y o f G l a d s t o n e P u b l i c W o r k s D e s i g n S t a n d a r d s T a b l e o f C o n t e n t s SECTION THREE SANITARY SEWER REQUIREMENTS... 1 3.0000 SANITARY SEWERS... 1 3.0010 General
More informationGWINNETT COUNTY STORM SEWER PIPE STANDARDS
1.0 Standard Specifications GWINNETT COUNTY STORM SEWER PIPE STANDARDS 1.1 Unless otherwise specifically set forth herein or in the Gwinnett County Standard Drawings, all of the materials, methods of the
More informationCONSTRUCTION SURVEY. Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following:
CONSTRUCTION SURVEY PART 1 - GENERAL 1.01 SECTION INCLUDES Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following: A. Construction Survey: 1. Project
More informationSECTION EARTHWORK
SECTION 02200 EARTHWORK PART 1 - GENERAL 1.01 WORK INVOLVED A. Provide all labor, materials and equipment as required for all excavation, grading, providing borrow materials, hauling, placing and compacting
More informationCITY OF MERIDIAN LAND DEVELOPMENT SERVICES SUBDIVISION PLAN REVIEW CHECK LIST
Project Name: Hearing Date: Reviewer: Date of Review: # OK NEED N/A General Plan Design All documents, design standards, specifications, and forms should be taken from the website each time they are used
More informationB. Backfill and compact utility bedding and fill placed in the utility trenches between the top of the utility bedding and the subgrade elevation.
SECTION 312333 TRENCHING AND BACKFILLING PART 1 - GENERAL 1.1 SUMMARY A. Excavate trenches for new electric and telephone conduits, gas lines, and their appurtenances from at least 5 feet outside the building
More informationSECTION CONSTRUCTION SERVICES
SECTION 01100 CONSTRUCTION SERVICES PART 1 GENERAL 1.01 - Section Includes A. Mobilization. B. Construction Surveys. C. Record Documents. 1.02 Description Of Work A. Mobilization: includes the preparatory
More informationSITE PLAN AND ARCHITECTURAL REVIEW APPLICATION
SITE PLAN AND ARCHITECTURAL REVIEW APPLICATION CITY OF GENEVA, NEW YORK The purpose of the site plan and architectural review process is to secure compliance with the City s Zoning Ordinance and to promote
More informationSTANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION CITY OF WEST BEND, WISCONSIN SECTION 300 EARTHWORK, GRADING, AND GRAVELING
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION CITY OF WEST BEND, WISCONSIN SECTION 300 EARTHWORK, GRADING, AND GRAVELING Section Number Title 301 GENERAL 302 MATERIALS SPECIFICATIONS 303 CLEARING
More informationTOWN OF LAFAYETTE SPECIFICATIONS FOR HIGHWAY CONSTRUCTION. June 1984
1 TOWN OF LAFAYETTE SPECIFICATIONS FOR HIGHWAY CONSTRUCTION June 1984 1. DEFINITIONS APPROVAL, APPROVED, ACCEPTED OR WORDS OR TERMS OF SIMILAR MEANING: Written approval of the Highway Superintendent. BASE
More informationEXCAVATION WORK IN PUBLIC RIGHT-OF-WAY GENERAL NOTES
CITY OF SANTA MONICA Department of Public Works Civil Engineering Division 1685 Main, Room 116 Santa Monica, CA 90401 Tel: (310) 458-2240 or (310) 458-8737 EXCAVATION WORK IN PUBLIC RIGHT-OF-WAY GENERAL
More informationWESTERN ENGINEERING CONSULTANTS, Inc LLC
WESTERN ENGINEERING CONSULTANTS, Inc LLC 127 S. Denver Avenue, Ft. Lupton CO 80621 2501 Mill St. Brush, CO 80723 Ph. 303-913-7341, Fax 720-294-1330 Email: firstname.lastname@westerneci.com August 24, 2017
More informationSECTION EXCAVATION, BACKFILLING AND COMPACTING
PART 1 GENERAL 1.01 SCOPE Work of this Section shall include all labor, materials, equipment, plant and incidentals required to complete all excavation, backfilling and compacting as indicated on the Drawings
More informationSECTION 10 - TRENCHING AND BACKFILLING
SECTION 10 - TRENCHING AND BACKFILLING 10.1 General A. Work included in this Section includes trenching and backfilling for underground pipelines and related structures only. 10.1.1 Related requirements
More information1.02 RELATED WORK: Refer to the following sections for related work: Section 4000-Concrete Materials and Methods
SECTION 2000- EARTHWORK PART 1- GENERAL 1.01 SCOPE: This Section covers excavation, fill, and compaction of earth and rock for roadway, embankments, structural foundations, and planted areas. Topics include
More information