1 External Applications Technical Manual ANY BUILDING ANY SURFACE ANYWHERE INEX BOARDS

2 INEX BOARDS Decking External Applications Technical Manual

3 Contents INEX>RENDERBOARD Product Information INEX>RENDERBOARD Physical Properties INEX>RENDERBOARD Installation INEX>RENDERBOARD Typical Assembly Details INEX>RENDERBOARD Timber Frame Systems INEX>RENDERBOARD Steel Frame Systems INEX>WEATHERBOARD Product Information INEX>WEATHERBOARD Physical Properties INEX>WEATHERBOARD Installation INEX>WEATHERBOARD Typical Assembly Details INEX>WEATHERBOARD Timber Frame Systems INEX>WEATHERBOARD Steel Frame Systems 0 INEX>EXPRESS Product Information INEX>EXPRESS Physical Properties 0 INEX>EXPRESS Typical Assembly Details INEX>EXPRESS Assembly Details Express Horizontal INEX>EXPRESS Assembly Details Express Vertical INEX>EXPRESS Stain Colour Range INEX>BOND Product Information Technical Manual INEX BOARDS External Applications

4 INEX BOARDS INEX>BOARDS provide a range of high performing, lighter weight materials for the construction industry. INEX>BOARDS offer a superior, yet price competitive, environmentally friendly alternative to fibre cement and plasterboard products. Critically the products are both low carbon and high performing, whilst at the same time being affordable, delivering to the construction industry a better, safer and cost-effective solution. Below we summarise some of the benefits of INEX>BOARDS: Low Carbon INEX>BOARDS minimise harm to the planet in their production which is undertaken at room temperature. The embodied energy of our board is about 0% to that of comparable fibre cement boards. Strength INEX>BOARDS are manufactured to an equilibrium bending strength of MPa. Fire Resistance Tests demonstrate that INEX>BOARDS are non-combustible, BAL-FZ and FRL 0/0/0 rated. Performance data available at Durability INEX>BOARDS can be used in all climatic conditions rain, snow, frost, varying humidities and extreme temperatures. Stability Tests demonstrate that INEX>BOARDS can retain over 0% of the dry strength after soak-dry cycles. Acoustic Resistance Tests demonstrate an acoustic attenuation of Rw higher than that of standard plasterboard products. At 0mm thickness INEX>BOARDS provide a similar attenuation as mm thick sound rated plasterboard. Water Resistance INEX>BOARDS have a high level of water resistance and conform to the requirements of the Water Permeability Test. Impact Resistance INEX>BOARDS offer high impact resistance greater than that of traditional compressed fibre cement sheets or impact resistant plasterboards currently on the market. Radiation Shielding Tests show enhanced electromagnetic radiation shielding properties. Healthier Living INEX>BOARDS are non-toxic, provide enhanced breathability and inhibit mould. INEX>BOARDS are manufactured by UBIQ Australia. Brickworks are now distributing the INEX>BOARDS range of products throughout Australia. INEX BOARDS External Applications Technical Manual

5 INEX RENDERBOARD Technical Manual INEX BOARDS External Applications

6 INEX RENDERBOARD Product Information PRODUCT LENGTH (mm) WIDTH (mm) THICKNESS (mm) Kg/m Kg/Sheet INEX>RENDERBOARD INEX>RENDERBOARD INEX>RENDERBOARD is a revolutionary, low carbon, high strength, yet lightweight cement based interior and exterior wall cladding suitable for both residential and commercial applications. INEX>RENDERBOARD has a tongue and groove joint down each long side for a flush tight fit and to minimise any later joint cracking. The rough side of INEX>RENDERBOARD provides a superb textured finish for multiple render system applications. BAL- FRL 0/0/0 WEIGHT At Approx. 0kg or kg INEX>RENDERBOARD is lightweight and easy to handle on site. HIGH PERFORMANCE INEX>RENDERBOARD can be cut and worked just like comparable fibre cement sheets, but offers improved bending strength characteristics and finish quality. INEX>RENDERBOARD can be fixed to timber or steel studs with spacing at maximum 00mm centres. NON-COMBUSTIBILTY & FRL INEX>RENDERBOARD is non-combustible. It is approved for bushfire BAL-FZ construction and is certified to Fire Resistance of Level FRL 0/0/0. ACOUSTIC INEX>RENDERBOARD s on a timber or steel frame with R. insulation and 0mm plasterboard internal lining will deliver a sound insulation value of Rw/Rw+Ctr of /, which will satisfy all Categories of Transport Noise Corridors for external wall requirements. Delivers a render finish like no other. MATERIAL INEX>RENDERBOARD is an advanced high strength, low carbon fibre reinforced Engineered Cementitious Composite (ECC) product, containing 0% of post industrial recycled materials. It is toxin free and is 00% recyclable. VALUE INEX>RENDERBOARD is priced for value for the construction industry and competes strongly against all comparable products. Pricing is available on application to UBIQ or its distributors. INEX BOARDS External Applications Technical Manual

7 INEX RENDERBOARD Physical Properties INEX>RENDERBOARD is a high-strength lightweight internal or external walling sheet with tongue and groove edges. It is suitable for domestic and commercial applications and is manufactured to conform to the following requirements and standards. DIMENSIONAL AND GEOMETRICAL CHARACTERISTICS GEOMETRICAL TESTS EQUILIBRIUM CONDITION STANDARD Length PASS AS/NZS 90. Width PASS AS/NZS 90. Thickness PASS AS/NZS 90. Straightness PASS AS/NZS 90. Squareness PASS AS/NZS 90. PHYSICAL CHARACTERISTICS APPARENT DENSITY TEST kg/m³ STANDARD mm INEX>RENDERBOARD AS/NZS Clause.. - test method... Condition: Mass determined by drying out the test specimens in a ventilated oven maintained at 00 C for hrs. STRENGTH CHARACTERISTIC TYPE TEST DRY CONDITION WET CONDITION STANDARD Bending Strength (Mean) >MPa >0MPa AS/NZS Clause. - test method.. Classification - Type A* AS/NZS 90. Category AS/NZS 90. Modulus of Elasticity >GPa >0GPa AS *Type A is intended for external applications where it may be subjected to the direct action of sun, rain and /or snow. DURABILITY, MOISTURE RESISTANCE AND CORROSION CHARACTERISTIC TYPE TEST THERMAL PROPERTIES CHARACTERISTIC TYPE TEST OTHERS MATERIAL TEST STANDARD Water Permeability PASS AS/NZS clause. - test method.. Frost Resistance PASS AS/NZS clause. - test method.. Heat-rain PASS AS/NZS clause. - test method B. Soak-dry PASS AS/NZS clause. - test method.. Corrosion Corrosion Tests undertaken by SGS Australia Pty. Ltd. demonstrate that INEX>RENDERBOARD does not accelerate corrosion on class or higher metal fasteners & fixings. STANDARD Thermal Conductivity 0.9 W/m.K AS/NZS 9. R-Value at mm Thickness 0.09 m².k/w AS/NZS 9. R-Value (typical wall system). m.k/w Building Code of Australia Specification J. Assumes R. thermal insulation, minimum mm cavity & 0mm plasterboard internal lining. Flammability Index 0 AS Ignitability Index 0 AS/NZS 0.:999 Spread of Flame Index 0 AS/NZS 0.:999 Heat Evolved Index 0 AS/NZS 0.:999 Smoke Developed Index AS/NZS 0.:999 Combustibility PASS - Not deemed Combustible AS clause. & AS/NZS :99 Building Code of Australia - Specification A. Bush Fire Attack Level BAL-0 PASS AS/NZS 0.. Bush Fire Attack Level BAL-FZ PASS AS & AS Asbestos PASS - Asbestos Free AS 9-00 Fungal Resistance PASS No growth ASTM C-0 VOC Emission Very Low (0.0mg/m /hr) ASTM D STANDARD / METHOD Technical Manual INEX BOARDS External Applications

8 INEX RENDERBOARD Installation PRODUCT WEIGHT At approx. kg (mm) INEX>RENDERBOARD is lightweight and easy to handle on site. STORAGE INEX>RENDERBOARD should be stored dry, flat and with all edges protected from damage. We recommend storage undercover and raised from the ground. HANDLING Wear protective gloves when handling or cutting sheets. SUPPORT FRAMING INEX>RENDERBOARD can be fixed to timber or steel studs with spacing at maximum 00mm centres. In all cases a cavity batten system must be installed. Choice and depth of batten is optional (see assembly drawings inside this document). Timber framing must be in accordance with AS Residential timber-framed construction. Steel framing must be in accordance with AS Domestic metal framing. Ensure framing is plumbed prior to fitting. FIXING WALL SYSTEMS ASSEMBLY INEX>RENDERBOARD must be fitted to a staggered layout. With its tongue and groove long sides it can be end match off-stud, however in this circumstance we recommend the use of backing boards at these joints as illustrated for our fire rated system. Ensure framing and INEX>RENDERBOARD are clean and dry prior to fitting. FIXINGS: Ensure all fixings are located: 0mm Min. from all tongue and grooves,mm min. from all butt joints 0mm Min. from all corners Max. 0mm centres along studs FIXINGS TIMBER JOISTS Class Galvanised Fixings or higher* Screws: 0gx0mm self-embedding countersunk head screws. FIXINGS STEEL JOISTS Class Galvanised Fixings or higher* Screws: gx0mm self-drilling, self-embedding, countersunk head screws. *Class or Stainless Steel screws for sea spray zone in accordance with AS. WALL SYSTEMS INEX>RENDERBOARD can be installed in conjunction with a variety of lightweight wall systems and finished with a range of coatings. INEX>RENDERBOARD delivers a BAL-FZ* and/or a Fire Resistance Level ( FRL) of 0/0/0 without the need for any fire rated plasterboard. Refer to the following page for further details of this fire rated system. * BAL-FZ (Flame Zone) is the highest Bushfire Attack Level where there is an extremely high risk of ember attack and burning debris ignited by windborne embers, and a likelihood of exposure to an extreme level of radiant heat and direct exposure to flames BAL-FZ from the fire front. It is equivalent to FRL 0/0/0. FRL 0/0/0 INEX BOARDS External Applications Technical Manual

9 INEX>RENDERBOARD FINISHING SYSTEMS INSULATION BATT VAPOUR PERMEABLE WALL WRAP ROUGH SIDE FACING OUT TONGUE & GROOVE JOINT MINIMISES JOINT CRACKING OF THE RENDER COAT. RENDER SYSTEM RENDER FINISH Install INEX>RENDERBOARD with the ROUGH SIDE FACING OUT so that the approved RENDER SYSTEM achieves optimum adhesion to the INEX>RENDERBOARD substrate. Refer to the Coatings section at for approved render coat systems. FRAMING SYSTEMS INEX>RENDERBOARD must be fixed to either timber or light gauge steel framing at a maximum of 00mm centres, and in all cases a cavity batten system must be installed. MAXIMUM STUD SPACING WIND CLASSIFICATION STUD SPACING Non-cyclonic Cyclonic General areas Within 00mm of building (mm) of building edges (mm) N, N, N C N, N C, C 00 0 N C 0 0 Stud spacings for INEX>RENDERERBOARD for the wind load classifications of AS 0 Wind Loads for Housing are given in the above table. INEX>RENDERBOARD is ideally suited for lightweight construction providing a fast-track cladding system during construction, resulting in both cost and time saving benefits. FRL 0/0/0 & BAL-FZ WALL SYSTEMS INEX>RENDERBOARD wall system, when used with a minimum mm steel furring channel or batten on either a timber or steel frame has achieved an FRL of 0/0/0 when tested against the Australian Standard AS0.-00 and therefore is suitable for BAL-FZ* construction in accordance with AS There is no fire rated plasterboard required for these systems, details of which are provided in this document. BAL-FZ FRL 0/0/0 BAL-FZ SYSTEM IN TIMBER STUD FRAME AS AS BAL-FZ SYSTEM IN STEEL STUD FRAME AS AS BAL-FZ FRL 0/0/0 Technical Manual INEX BOARDS Flooring Applications 9

10 INEX RENDERBOARD LAYING PATTERN Figure INEX>RENDERBOARD must be fitted in a staggered pattern to achieve the best surface and finish. Vertical butt joint locations are subject to stud spacing. Refer to Figure. For render application, INEX>RENDERBOARD must be fitted with rough side facing out for best adhesion. MOVEMENT CONTROL JOINT Despite the fact that INEX>RENDERBOARD is dimensionally stable, movement control joints must be installed to relieve any stress on building materials due to temperature changes, sway caused by wind, seismic events and etc. Vertical movement control joints are to be provided where wall lengths exceed m, at internal changes of wall direction and at openings such as windows and doorways or where existing structural joints are located. Refer to Figure. Horizontal movement control joints must also be provided at each floor level, subject to designer s detailing. Control joints should be installed evenly and symmetrically for large size walls. FOAM BACKER ROD / AIR SEAL INEX>RENDERBOARD INEX>RENDERBOARD STARTER & CORNER TRIMS When applying render to INEX>RENDERBOARD, starter trims and corner trims must be fixed in accordance with trim or render manufacturer s instructions. To achieve best adhesion between trim and render, ensure that the render fully covers both INEX>RENDERBOARD and the trim, thus resulting in a perfectly flat and seamless rendered surface. RENDER SYSTEM VEE JOINT INEX>BOND OR PAINTABLE POLYURETHANE FLEXIBLE SEALANT Figure ONE EXAMPLE OF MOVEMENT CONTROL JOINT STARTER TRIM ➊ -RST-. CORNER TRIM ➋ -RMESH-. ➊ ➋ 0 INEX BOARDS External Applications Technical Manual

11 INSTALLATION EQUIPMENT UBIQ recommends the following equipment and accessories for the installation of INEX>RENDERBOARD: GENERAL: CUTTING: SCREW FIXING: INEX>RENDERBOARD can be machined and worked in same way as comparable fibre cement wall sheeting. INEX>RENDERBOARD should be cut using a mechanical dust reducing circular saw with a diamond edge blade, similar to that used to cut softer brick or stone or the ones specifically used to cut fibre cement sheet. See also Health & Safety section below. INEX>RENDERBOARD must be screw fixed only. Use a cordless power drill. DUST LIMITATION: Always limit dust with a vacuum dust extraction system with a suitable filter. CONTROL JOINT: When installing INEX>RENDERBOARD in situation where wall height is more than one storey, horizontal movement control joints are required at each level. Standard V-joints, starter trims or shadowline trims can be used, subject to designer s detailing. Movement control joints are to be provided where wall dimensions exceed m in the long sheet direction, at changes of wall direction and at openings such as windows and doorways or where existing structural joints are located. BACKING ROD: Where movement control joints are needed in any INEX>RENDERBOARD application, use a closed cell PE foam backing rod of 0 mm diameter to control the design depth of INEX>BOND adhesive/sealant used to seal the joint. For more details refer to the INEX>BOND product data sheet. Important Notes: Ensure all components are compatible with each other and suitable for INEX>RENDERBOARD and/or the intended surface finish. Failure to install, finish or maintain this product in accordance with relevant building codes, regulations, standards and UBIQ s current published instructions may lead to personal injury, affect system performance, violate local building codes, and possibly void the product warranty. HEALTH & SAFETY UBIQ advises that INEX>RENDERBOARD contains fiberglass reinforcing and causes fine dust when cutting or machining. Continuous or excessive inhalation of fine dust containing fiberglass particles can cause irritation and may cause lung scarring (silicosis). This dust could be carcinogenic as all dust may be. Exposure to such dust may cause irritation to the skin or other body surfaces. When cutting INEX>RENDERBOARD use methods recommended in this brochure to minimise dust production, and in addition: LOCATION: Do not cut INEX>RENDERBOARD indoors. Cut in a well ventilated outdoor location. CLOTHING, MASK & GOGGLES: Always wear protective clothing and properly fitted and approved mask (respirator) and eye protective goggles. DUST LIMITATION: Always use a mechanical circular saw equipped with a fitted dust extraction system. When cutting is finished always vacuum up residual dust. Maintain the work area as a dust free environment. Note: Due to the cementitious nature of INEX>BOARDS some superficial pin-holing may occur. The smooth side of INEX>RENDERBOARD is characterised as a Class concrete finish. Technical Manual INEX BOARDS External Applications

12 INEX RENDERBOARD Typical Assembly Details The following pages show the common junctions of INEX>RENDERBOARD assembly on either timber or steel framing with other building elements, such as framed or concrete floors, and intersections of walls. Important considerations with respect to choice of framing surround the choice of battens, as follows: Batten Selection In all cases INEX>RENDERBOARD must be installed with a frame with a cavity batten system. This best practice framed wall system allows INEX>RENDERBOARD to breathe and will help to minimise long term future issues such as water penetration. Battens can be laid to a vertical or horizontal orientation on the face of the studs depending upon the desired orientation of the boards. They can be either timber or steel. Importantly, this cavity system can deliver a Fire Resistance Level (FRL) or Bushfire Attack Level (BAL) to the wall systems, the FRL or BAL rating of which is determined by the choice of batten. The table below describes the FRL or BAL outcomes achieved by choice of framing and/or batten. FRAME TIMBER STEEL BATTEN VERTICAL MIN mm MIN mm (Furring channel) 0/0/0 (BAL-FZ) 0/0/0 (and/or BAL-FZ) BATTEN HORIZONTAL TIMBER FRL or BAL STEEL FRL or BAL MIN mm* (Top Hat) 0/0/0 (and/or BAL-FZ) *Depth of top hat will be subject to wind load criteria and structural design of the overall frame. INEX BOARDS External Applications Technical Manual

13 Horizontal Battens & Vertical Boards EXP. JOINT AT EACH SHEET OR STOREY SINGLE SHEET EXP. JOINT AT EACH SHEET OR STOREY SHEET LENGTH 00mm or 000mm VERTICAL EXPANSION JOINT AT Max..m CENTRES (9 SHEETS) OR AS OTHERWISE REQUIRED Vertical Battens & Horizontal Boards SHEET LENGTH 00mm or 000mm EXP. JOINT AT EACH STOREY FIX BOARDS TO STACK PATTERN (WHERE JOINED OFF STUD SECURE WITH BACKING PLATE) TONGUE FACING UP AT ALL HORIZONTAL JOINS SHEET WIDTH 00mm EXP. JOINT AT EACH STOREY VERTICAL EXPANSION JOINT AT MAX METRES OR AS OTHERWISE REQUIRED SINGLE SHEET Technical Manual INEX BOARDS External Applications

14 INEX RENDERBOARD Horizontal Battens Fixed to Frame Details MAX 00mm BETWEEN STUDS MAX MAX 00mm 00mm BETWEEN STUDS STUDS MAX 00mm BETWEEN STUDS MAX MAX 00mm 00mm BETWEEN BETWEEN STUDS STUDS TOP HAT WITH TAPERED LEGS TOP HAT TOP HAT WITH TAPERED LEGS TIMBER STUD STUD MAX. MAX. 00mm 00mm BETWEEN BETWEEN TOP TOP TOP HATS HATS HATS TIMBER STUD TIMBER TIMBER STUD STUD FIXING OF TOP HAT TO TOP STUD HAT IN TOACCORDANCE STUD FIXING OF TOP HAT TO WITH WITH SPAN TABLES?? STUD GUAGE IN ACCORDANCE MIN WITH Class SPAN TABLES GALV. SCREW (Min.??mm INTO STUD) STEEL STUD FIXING OF TOP HAT TO TOP HAT STUD TOIN ACCORDANCE STUD FIXING OF TOP HAT TO WITHSPAN TABLES?? GUAGE STUD IN ACCORDANCE MIN Class WITH SPAN TABLES GALV. SCREW (Min.??mm INTO STUD) STEEL STEEL STUD STUD STEEL STUD STEEL STEEL STUD STUD TOP HAT WITH TAPERED LEGS TOP HAT WITH TAPERED LEGS HORIZONTAL BATTENS - FIX FIX TO TO FRAME DETAILS Vertical HORIZONTAL Battens Fixed BATTENS to Frame Min. mm DEEP STEEL Min. mm DEEP TIMBER - FIX Details TO FRAME DETAILS BATTEN RQRD FOR FRL Min. 0/0/0 mm DEEP & BAL-FZ TIMBER BATTEN RQRD FOR FRL 0/0/0 & BAL-FZ FURRING CHANNEL ON CLIPS Min. RQRD mm FOR DEEP STEEL FRL FURRING 0/0/0 CHANNEL ON CLIPS RQRD FOR FRL 0/0/0 FIXING CLIP # FIXING CLIP FURRING CHANNEL #0 FURRING CHANNEL MAX. 0mm MAX. 0mm 0 GAUGE MIN Class GALV. SCREW (Min. 0 GAUGE 0mm INTO MIN Class STUD) GALV. SCREW (Min. 0mm INTO STUD) TIMBER TO TIMBER TIMBER TO TIMBER??? GAUGE MIN Class GALV. SCREW (Min. 0mm CLIP FIXING IN INTO STUD) ACCORDANCE WITH SPAN TABLES No.??? GAUGE MIN Class GALV. SCREW (Min. 0mm INTO STUD) FIXING CLIPS AT MAX. 0mm c/c FIXING CLIPS AT MAX. 0mm c/c?? x?? x?? ANGLE SUPPORT FOR FURRING CHANNEL (Max. SUPPORT METRE FOR EACH LENGTH FURRING OF CHANNEL CHANNEL ABOVE) (Max. METRE LENGTH OF CHANNEL ABOVE) FURRING CHANNEL TO TIMBER FURRING CHANNEL TO TIMBER??? GAUGE Min. Class GALV. SCREW (Min. CLIP mm FIXING IN INTO ACCORDANCE STUD) WITH SPAN TABLES FURRING CHANNEL TO STEEL FURRING CHANNEL TO STEEL VERTICAL BATTENS - FIX TO FRAME DETAILS NOTE: These diagrams provide indicative fixing details only. Size, fixing/connections and arrangment of timber and/or steel frame and other elements such as battens will vary according to wind load criteria and other strucural considerations. Refer to WIND LOAD SPAN TABLES for further information. INEX BOARDS External Applications Technical Manual FIXING CLIPS AT MAX. 0mm c/c FIXING CLIPS AT MAX. 0mm c/c?? x?? x?? ANGLE SUPPORT FOR FURRING CHANNEL (Max. SUPPORT METRE FOR EACH LENGTH FURRING OF CHANNEL CHANNEL ABOVE) (Max. METRE LENGTH OF CHANNEL ABOVE) VERTICAL BATTENS - FIX TO FRAME DETAILS NOTE: These diagrams provide indicative fixing details only. Size and arrangment of timber and/or steel frame and other elements such as battens will vary according to wind load criteria and other strucural considerations. Refer to WIND LOAD SPAN TABLES overleaf for further information. FIXING CLIPS AT MAX. 0mm c/c No.??? GAUGE Min. Class GALV. SCREW (Min. mm INTO STUD) FIXING CLIPS AT MAX. 0mm c/c

15 Technical Manual INEX BOARDS Flooring Applications

16 INEX RENDERBOARD Timber Frame System: FRL 0/0/0 & BAL-FZ Timber studs at Max. 00mm centres to AS Option for Min. mm deep steel batten/top hat Option for Min. mm deep timber batten Option for any insulation Vapour permeable building wrap INEX>RENDERBOARD Joins on stud require sealing with proprietary fire sealant such as Bostik Fireban Option for multiple approved render coat systems 0mm thick standard grade plasterboard or equivalent Joins off stud fixed with backing board (see overleaf) Achieves FRL 0/0/0 when tested to AS0.-00 Meets AS Section 9 (BAL-FZ) via testing to AS0.-00 INEX BOARDS External Applications Technical Manual

17 RENDERBOARD FRL 0/0/0 & BAL-FZ TIMBER FRAME ALL JOINS OFF STUD WITH BACKING PLATE (NO SEALANT RQRD) ALL JOINS OFF STUD WITH BACKING PLATE (NO SEALANT RQRD) 0 EQ 0 0 EQ 0 0 EQ 0 ALL JOINS ON STUD REQUIRE SEALING WITH PROPRIETARY FIRE SEALANT SUCH AS BOSTIK 'FIREBAN ' ALL JOINS ON STUD REQUIRE SEALING WITH PROPRIETARY FIRE SEALANT SUCH AS BOSTIK 'FIREBAN ' TONGUE FACING UP AT TONGUE AND GROOVE JOINT 0 EQ EQ EQ EQ MAX 00 0 MAX 00 TONGUE FACING UP AT TONGUE AND GROOVE JOINT MAX x 00 BACKING PLATE (CUT FROM RENDERBOARD) 00x00 INEX>RENDERBOARD MIN mm TIMBER BATTEN 00 x 00 BACKING PLATE (CUT FROM RENDERBOARD) ANY BEATHABLE WALL WRAP MIN mm TIMBER BATTEN 00x00 INEX>RENDERBOARD ANY BEATHABLE WALL WRAP TIMBER STUD FRAME ANY INSULATION TIMBER STUD FRAME 0mm PLASTERBOARD OR SIMILAR ANY INSULATION 0g MIN Class GALVANISED COUNTER 0mm SINKING PLASTERBOARD SCREWS OR SIMILAR 0g MIN Class GALVANISED COUNTER SINKING SCREWS Technical Manual INEX BOARDS External Applications

18 INEX RENDERBOARD Timber Frame System: FRL 0/0/0 & BAL-FZ Timber studs at Max. 00mm centres to AS Option for Min. mm deep furring channel on proprietary fixing clips Option for any insulation Vapour permeable building wrap INEX>RENDERBOARD Option for multiple approved render coat systems 0mm thick standard grade plasterboard or equivalent All joins off stud and with backing plate (no sealant required) Achieves FRL 0/0/0 when tested to AS0.-00 Meets AS Section 9 (BAL-FZ) via testing to AS0.-00 INEX BOARDS External Applications Technical Manual

19 RENDERBOARD FRL 0/0/0 & BAL-FZ TIMBER FRAME ALL JOINS OFF STUD WITH BACKING PLATE (NO SEALANT RQRD) MAX 00 ALL JOINS OFF STUD WITH BACKING PLATE (NO SEALANT RQRD) MAX 00 0 EQ 0 0 EQ EQ 0 0 EQ 0 0 ALL JOINS ON STUD REQUIRE SEALING WITH PROPRIETARY FIRE SEALANT SUCH AS BOSTIK 'FIREBAN ' ALL JOINS ON STUD REQUIRE SEALING WITH PROPRIETARY FIRE SEALANT SUCH AS BOSTIK 'FIREBAN ' TONGUE FACING UP AT TONGUE AND GROOVE JOINT TONGUE FACING UP AT MAX 00 TONGUE AND GROOVE JOINT 0 EQ EQ EQ EQ x00 INEX>RENDERBOARD ANY BEATHABLE WALL WRAP 00 x 00 BACKING PLATE (CUT 00x00 FROM RENDERBOARD) INEX>RENDERBOARD MIN mm STEEL FURRING CHANNEL, on 00x00 x 00 BACKING PLATE PROPRIETARY (CUT FROM INEX>RENDERBOARD) FIXING CLIPS SUCH AS:- - RONDO 9mm #9 or mm #0 FIXED WITH RONDO MIN. # mm CLIP STEEL FURRING CHANNEL, on - STUDCO on PROPRIETARY 0mm TOP HAT FIXING FIXED CLIPS WITH CLIPS, SUCH STUDCO SUCH AS:- CLIP) AS: - RONDO 9mm #9 or mm #0 FIXED WITH RONDO # # CLIP CLIP - STUDCO 0mm TOP HAT FIXED WITH STUDCO CLIP) TIMBER STUD FRAME ANY BREATHABLE BEATHABLE WALL WRAP ANY INSULATION TIMBER STUD FRAME 0mm PLASTERBOARD OR SIMILAR ANY INSULATION 0g MIN Class GALVANISED COUNTER 0mm SINKING PLASTERBOARD SCREWS OR SIMILAR 0g MIN Class GALVANISED COUNTER SINKING SCREWS Technical Manual INEX BOARDS External Applications 9

20 INEX RENDERBOARD IMBER FRAME VERTICAL BATTENS ASSEMBLY DETAILS Timber Frame Vertical Batten Assembly Details BATTEN DRAWN AT mm (F) PLAN PLAN CAVITY FRL 0/0/0 FRL 0/0/0 EXTERNAL CORNER RENDER BEAD INEX>BOND, OR OTHER PAINTABLE POLYURETHANE FLEXIBLE SEALANT ON BACKING ROD (or proprietary fire sealant if FRL required) EXPANSION JOINT EXPANSION JOINT EXPANSION JOINT RENDER BEAD (or proprietary fire sealant on backing rod if FRL required) APPROVED RENDERCOAT SYSTEM TIMBER STUD FRAME 00x00 INEX>RENDERBOARD Rough side facing outwards MIN mm TIMBER BATTEN (mm or greater delivers FRL 0/0/0) OPTION FOR METAL BATTEN (to deliver FRL 0/0/0) MIN mm STEEL FURRING CHANNEL, on PROPRIETARY FIXING CLIPS SUCH AS:- - RONDO 9mm #9 or mm #0 FIXED WITH RONDO # CLIP - STUDCO 0mm TOP HAT FIXED WITH STUDCO CLIP 9 ANY BREATHABLE WALL WRAP ANY INSULATION 0mm PLASTERBOARD OR SIMILAR 0mm x 0 GUAGE MIN Class GALV. COUNTER SINKING SCREWS (0mm LONG FOR STEEL BATTENS) 0 INEX BOARDS External Applications Technical Manual

21 INEX>FLOOR FFL JOIST CONCRETE GROUND SLAB 9 MIN mm CONCRETE PAD OR STRIP FOOTING (strip footing required for FRL) BEARER 9 WALL ON WALL ON BEARERS BEARERS RENDER STARTER TRIM WITH SNAP 0 TO SUIT CHOSEN BATTEN THICKNESS (see below). IF FRL REQUIRED:- - Install fire stop or - Locate concrete edge mm behind INEX>RENDERBOARD (see details below) WALL ON GROUND SLAB WALL ON GND SLAB INEX>FLOOR BATTEN DRAWN AT mm (F) FFL mm GAP TO FACE OF CONCRETE 9 METAL FLASHING MIN mm FRL OPTION mm GAP TO FACE OF CONCRETE FRL OPTION 9 METAL FLASHING STARTER TRIM WITH SNAP (see below). FRL OPTION FRL OPTION STARTER TRIM WITH SNAP (see below). RENDER STARTER TRIM No. -RST-.. by MULTI-SIZE RENDER STARTER TRIM mm mm mm 0 x SNAP POINTS SNAP 0 (FULL TRIM) SNAP SNAP SNAP MULTI-SIZE RENDER STARTER TRIM Technical Manual INEX BOARDS External Applications

22 INEX RENDERBOARD CORNER HEAD RENDER BEAD WITH DRIP MOULD + RENDER STOP BEAD FLASHING as required by window manufacturer EXTERNAL CORNER RENDER BEAD + RENDER STOP BEAD STORM MOULD OR SELANT HEAD FLASHING as required by window manufacturer JAMB SILL EDGE RENDER BEAD + RENDER STOP BEAD BATTEN DRAWN AT mm (F) SILL APPROVED RENDERCOAT SYSTEM TIMBER STUD FRAME 00x00 INEX>RENDERBOARD Rough side facing outwards ANY BREATHABLE WALL WRAP MIN mm TIMBER BATTEN (mm or greater delivers FRL 0/0/0) OPTION FOR METAL BATTEN (to deliver FRL 0/0/0) MIN mm STEEL FURRING CHANNEL, on PROPRIETARY FIXING CLIPS SUCH AS:- - RONDO 9mm #9 or mm #0 FIXED WITH RONDO # CLIP - STUDCO 0mm TOP HAT FIXED WITH STUDCO CLIP 9 ANY INSULATION 0mm PLASTERBOARD OR SIMILAR 0mm x 0 GUAGE MIN Class GALV. COUNTER SINKING SCREWS (0mm LONG FOR STEEL BATTENS) INEX BOARDS External Applications Technical Manual

23 SELECTED METAL CAPPING ROOF 9 NOTE: PARAPET WALL SHALL BE DESIGNED AN FASTENED IN ACCORDANCE WITH SAA -HB INSTALLATION CODE FOR METAL ROOFING AND WALL CLADDING. STOP ENDS SHALL BE INCORPARATED TO ALL FLASHINGS PARAPET RENDER STOP BEAD FLASHING as required by window manufacturer RENDER STOP BEAD CONTINUOUS BEAD OF JOINT SEALANT HEAD JAMB JAMB FLASHING as required by window manufacturer SILL BATTEN DRAWN AT mm (at this thickness will require min mm long screws to fix INEX>RENDERBOARD through to stud behind) Technical Manual INEX BOARDS External Applications

24 INEX RENDERBOARD Steel Frame System: FRL 0/0/0 & BAL-FZ Steel studs at Max. 00mm centres to AS/NZS00 Option for Min. mm deep furring channel on proprietary fixing clips Option for any insulation Vapour permeable building wrap INEX>RENDERBOARD Option for multipe approved render coat systems 0mm thick standard grade plasterboard or equivalent All joins off stud and with backing plate (no sealant required) Achieves FRL 0/0/0 when tested to AS0.-00 Meets AS Section 9 (BAL-FZ) via testing to AS0.-00 INEX BOARDS External Applications Technical Manual

25 RENDERBOARD FRL 0/0/0 & BAL-FZ STEEL FRAME MAX ALL JOINS OFF STUD WITH BACKING PLATE (NO SEALANT RQRD) ALL JOINS OFF STUD WITH BACKING PLATE (NO SEALANT RQRD) 0 EQ 0 0 EQ EQ 0 EQ ALL JOINS ON STUD REQUIRE SEALING WITH PROPRIETARY FIRE SEALANT SUCH AS BOSTIK 'FIREBAN ' ALL JOINS ON STUD REQUIRE SEALING WITH PROPRIETARY FIRE SEALANT SUCH AS BOSTIK 'FIREBAN ' TONGUE FACING UP AT TONGUE AND GROOVE JOINT TONGUE FACING UP AT TONGUE AND GROOVE MAX 00 JOINT 0 EQ EQ 0 EQ 0 0 EQ MAX 00 00x00 INEX>RENDERBOARD ANY BEATHABLE WALL WRAP 00 x 00 BACKING PLATE (CUT 00x00 FROM RENDERBOARD) INEX>RENDERBOARD MIN 00x00 mm x 00 STEEL BACKING FURRING PLATE CHANNEL, on PROPRIETARY (CUT FROM INEX>RENDERBOARD) FIXING CLIPS SUCH AS:- - RONDO 9mm #9 or mm #0 FIXED WITH RONDO MIN. # mm CLIP STEEL FURRING CHANNEL, on - STUDCO on PROPRIETARY 0mm TOP HAT FIXING FIXED CLIPS WITH CLIPS, SUCH STUDCO SUCH AS:-CLIP) AS: - RONDO 9mm #9 or mm #0 FIXED WITH RONDO # # CLIP CLIP - STUDCO 0mm TOP HAT FIXED WITH STUDCO CLIP) ANY STEEL BREATHABLE BEATHABLE STUD FRAME WALL WRAP STEEL ANY INSULATION STUD FRAME ANY 0mm INSULATION PLASTERBOARD OR SIMILAR 0mm 0g MIN PLASTERBOARD Class GALVANISED OR SIMILAR COUNTER SINKING SCREWS 0g MIN Class GALVANISED COUNTER SINKING SCREWS Technical Manual INEX BOARDS External Applications

26 INEX RENDERBOARD STEEL FRAME VERTICAL BATTEN ASSEMBLY DETAILS Steel Frame Vertical Batten Assembly Details mm FURRING CHANNEL DRAWN PLAN PLAN FRL 0/0/0 EXTERNAL CORNER RENDER BEAD CAVITY INEX>BOND, OR OTHER PAINTABLE POLYURETHANE FLEXIBLE SEALANT ON BACKING ROD (or proprietary fire sealant if FRL required) EXPANSION JOINT EXPANSION JOINT EXPANSION JOINT RENDER BEAD (or proprietary fire sealant on backing rod if FRL required) APPROVED RENDERCOAT SYSTEM 00x00 INEX>RENDERBOARD Rough side facing outwards MIN mm METAL BATTEN (delivers FRL 0/0/0) mm STEEL FURRING CHANNEL, on PROPRIETARY FIXING CLIPS SUCH AS:- - RONDO 9mm #9 or mm #0 FIXED WITH RONDO # CLIP - STUDCO 0mm TOP HAT FIXED WITH STUDCO CLIP ANY BREATHABLE WALL WRAP STEEL STUD FRAME ANY INSULATION 0mm PLASTERBOARD OR SIMILAR 0mm LONG 0 GUAGE MIN Class GALV. COUNTER SINKING SCREWS INEX BOARDS External Applications Technical Manual

27 INEX>FLOOR mm FURRING CHANNEL DRAWN FFL PURLIN BEAM CONCRETE GROUND SLAB MIN mm MS ANGLE POST TO FOOTING NOTE: U/S OF FLOOR STRUCTURE NOT SHOWN TO FRL PERFORMANCE. IF REQUIRED, SPECIFIER TO DETAIL ACCORDINGLY. WALL ON FRAME WALL ON FRAME RENDER STARTER TRIM WITH SNAP TO SUIT CHOSEN BATTEN THICKNESS (see below). IF FRL REQUIRED:- - Install fire stop or - Locate concrete edge mm behind INEX>RENDERBOARD (see detail below) FFL WALL ON WALL GROUND ON GND SLAB SLAB METAL FLASHING mm GAP TO FACE OF CONCRETE MIN mm FRL OPTION FRL OPTION STARTER TRIM WITH SNAP (see below). RENDER STARTER TRIM No. -RST-.. by MULTI-SIZE RENDER STARTER TRIM mm mm mm 0 x SNAP POINTS SNAP 0 (FULL TRIM) SNAP SNAP SNAP MULTI-SIZE RENDER STARTER TRIM Technical Manual INEX BOARDS External Applications

28 INEX RENDERBOARD RENDER STOP BEAD RENDER STOP BEAD CONTINUOUS BEAD OF JOINT SEALANT FLASHING as required by window manufacturer HEAD FLASHING as required by window manufacturer JAMB JAMB SILL APPROVED RENDERCOAT SYSTEM ANY BREATHABLE WALL WRAP 00x00 INEX>RENDERBOARD Rough side facing outwards MIN mm METAL BATTEN (delivers FRL 0/0/0) mm STEEL FURRING CHANNEL, on PROPRIETARY FIXING CLIPS SUCH AS:- - RONDO 9mm #9 or mm #0 FIXED WITH RONDO # CLIP - STUDCO 0mm TOP HAT FIXED WITH STUDCO CLIP STEEL STUD FRAME ANY INSULATION 0mm PLASTERBOARD OR SIMILAR 0mm LONG 0 GUAGE MIN Class GALV. COUNTER SINKING SCREWS INEX BOARDS External Applications Technical Manual

29 Technical Manual INEX BOARDS External Applications 9

30 INEX RENDERBOARD Timber or Steel Frame Assembly Details Horizontal Battens BATTEN DRAWN AS mm HORIZONTAL TOP HAT Min. mm COLORBOND EQUAL ANGLE. - FIX TO INSIDE OF FIRST BOARD INTO CNR PRIOR TO FIX OF BOARD. PLAN PLAN FRL 0/0/0 RENDER EXTERNAL TRIM, SUCH AS -RMESH-., BY PLASTER TAPE AND TRIM (PTT) CAVITY INEX>BOND, OR OTHER PAINTABLE POLYURETHANE FLEXIBLE SEALANT (or proprietary fire sealant if FRL required) EXPANSION JOINT EXPANSION JOINT RENDER SEALANT EXPANSION JOINT, SUCH AS -RSEXP-., BY PLASTER TAPE AND TRIM (PTT) (FILL WITH SEALANT AFTER RENDER SYSTEM COMPLETE) APPROVED RENDERCOAT SYSTEM ANY BREATHABLE WALL WRAP 00x00 INEX>RENDERBOARD Rough side facing outwards Min. mm TOP HAT WITH TAPERED LEGS AT Max. 00mm VERTICAL CENTRES SUCH AS mm DEEP STUDCO M0 (0. BMT), or 0mm DEEP STUDCO TH0 (0. BMT) TIMBER OR STEEL STUD FRAME (BOTH DRAWN) ANY INSULATION 0mm PLASTERBOARD OR SIMILAR 0mm LONG GUAGE MIN Class GALV. COUNTER SINKING SCREWS 0 INEX BOARDS External Applications Technical Manual

31 Assembly Details Horizontal Battens TOP HAT 0 EQUAL EQUAL 0 0 EQUAL EQUAL 00 TOP HAT T&G JOINT TO INEX>RENDERBOARD HORIZONTAL JOINS ON TOP HAT(S) WHERE FRL REQUIRED SEAL WITH PROPRIETARY FIRE SEALANT SUCH AS BOSTIC 'FIREBAN ' MAX 00 TOP HAT CENTRES MAX 00 STUD FRAME MAX 00 STUD FRAME Technical Manual INEX BOARDS External Applications

32 INEX RENDERBOARD INEX>FLOOR mm TOP HAT DRAWN FFL PURLIN BEAM CONCRETE GROUND SLAB MIN mm MS ANGLE POST TO FOOTING NOTE: U/S OF FLOOR STRUCTURE NOT SHOWN TO FRL PERFORMANCE. IF REQUIRED, SPECIFIER TO DETAIL ACCORDINGLY. WALL ON FRAME WALL ON FRAME RENDER STARTER TRIM WITH SNAP TO SUIT CHOSEN BATTEN THICKNESS. IF FRL REQUIRED:- - Install fire stop or - Locate concrete edge mm behind INEX>RENDERBOARD (see detail below) FFL WALL ON GROUND WALL ON SLAB GND SLAB METAL FLASHING mm GAP TO FACE OF CONCRETE MIN mm STARTER TRIM WITH SNAP FRL OPTION FRL OPTION APPROVED RENDER COAT SYSTEM ANY BREATHABLE WALL WRAP 00x00 INEX>RENDERBOARD Rough side facing outwards Min. mm TOP HAT WITH TAPERED LEGS AT Max. 00mm VERTICAL CENTRES SUCH AS mm DEEP STUDCO M0 (0. BMT), or 0mm DEEP STUDCO TH0 (0. BMT) TIMBER OR STEEL STUD FRAME (STEEL DRAWN) ANY INSULATION 0mm PLASTERBOARD OR SIMILAR 0mm LONG 0 GUAGE MIN Class GALV. COUNTER SINKING SCREWS INEX BOARDS External Applications Technical Manual

33 SELECTED METAL CAPPING NOTE: PARAPET WALL SHALL BE DESIGNED AN FASTENED IN ACCORDANCE WITH SAA -HB INSTALLATION CODE FOR METAL ROOFING AND WALL CLADDING. STOP ENDS SHALL BE INCORPARATED TO ALL FLASHINGS ROOF PARAPET FFL EXPANSION JOINT RENDER BEAD (or proprietary fire sealant on backing rod if FRL required) HORIZONTAL JOINT (AT FLOOR JUNCTION, OR AS OTHERWISE RQRD). RENDER STOP BEAD RENDER STOP BEAD CONTINUOUS BEAD OF JOINT SEALANT HEAD HEAD FLASHING as required by window manufacturer FLASHING as required by window manufacturer JAMB SILL Technical Manual INEX BOARDS External Applications

34 INEX BOARDS External Applications Technical Manual

35 INEX WEATHERBOARD Technical Manual INEX BOARDS External Applications

36 INEX WEATHERBOARD Product Information PRODUCT LENGTH (mm) WIDTH (mm) COVERAGE (mm) THICKNESS (mm) Kg/m Kg/Length INEX>WEATHERBOARD INEX>WEATHERBOARD is a revolutionary, low carbon, high strength, yet lightweight cement based exterior wall cladding suitable for both residential and commercial applications. The long edges of INEX>WEATHERBOARD are precisely profiled to allow for easy installation and accurate overlaps, thus resulting in stunningly sharp horizontal lines that appeal to many designers. INEX>WEATHERBOARD has a tongue and groove joint down each short end for a flush tight fit and off stud jointing. The smooth side of INEX>WEATHERBOARD is an ideal surface for multiple paint applications. The rough sawn profile of INEX>WEATHERBOARD provides a superb linear textured finish for designers wishing to attain a BAL-FZ timber-grain weatherboard look. FRL 0/0/0 WEIGHT At approx. 0kg/m (mm) per length INEX>WEATHERBOARD is lightweight and easy to handle on site. HIGH PERFORMANCE INEX>WEATHERBOARD can be cut and worked just like other comparable fibre cement weatherboard, but offers improved bending strength characteristics and finish quality. INEX>WEATHERBOARD can be fixed to timber or steel studs with spacing at maximum 00mm centres. NON-COMBUSTIBILTY INEX>WEATHERBOARD is non-combustible. It is approved for bushfire BAL-FZ construction and is certified to Fire Resistance Level of FRL 0/0/0. ACOUSTIC INEX>WEATHERBOARD s on a timber or steel frame with R. insulation and 0mm plasterboard internal lining will deliver a sound insulation value of >Rw, which will satisfy Category of Transport Noise Corridors for external wall requirements. Systems to achieve all Categories of Transport Noise Corridors available on application. MATERIAL INEX>WEATHERBOARD is an advanced high strength, low carbon fibre reinforced Engineered Cementitious Composite (ECC) product, containing 0% of post industrial recycled materials. It is toxin free and is 00% recyclable. VALUE INEX>WEATHERBOARD is priced for value for the construction industry and competes strongly against all comparable products. Pricing is available on application to UBIQ or its distributors. INEX BOARDS External Applications Technical Manual

37 INEX WEATHERBOARD Physical Properties INEX>WEATHERBOARD is a high-strength lightweight external walling sheet with tongue and groove ends. It is suitable for domestic and commercial applications and is manufactured to conform to the following requirements and standards. DIMENSIONAL AND GEOMETRICAL CHARACTERISTICS GEOMETRICAL TESTS EQUILIBRIUM CONDITION STANDARD Length PASS AS/NZS 90. Width PASS AS/NZS 90. Thickness PASS AS/NZS 90. Straightness PASS AS/NZS 90. Squareness PASS AS/NZS 90. PHYSICAL CHARACTERISTICS APPARENT DENSITY TEST kg/m³ STANDARD mm INEX>WEATHERBOARD AS/NZS Clause.. - test method... Condition: Mass determined by drying out the test specimens in a ventilated oven maintained at 00 C for hrs. STRENGTH CHARACTERISTIC TYPE TEST DRY CONDITION WET CONDITION STANDARD Bending Strength (Mean) >MPa >MPa AS/NZS Clause. - test method.. Classification - Type A* AS/NZS 90. Category AS/NZS 90. Modulus of Elasticity >GPa >GPa AS *Type A is intended for external applications where it may be subjected to the direct action of sun, rain and /or snow. DURABILITY, MOISTURE RESISTANCE AND CORROSION CHARACTERISTIC TYPE TEST THERMAL PROPERTIES CHARACTERISTIC TYPE TEST OTHERS MATERIAL TEST STANDARD Water Permeability PASS AS/NZS clause. - test method.. Frost Resistance PASS AS/NZS clause. - test method.. Heat-rain PASS AS/NZS clause. - test method B. Soak-dry PASS AS/NZS clause. - test method.. Corrosion Corrosion Tests undertaken by SGS Australia Pty. Ltd. demonstrate that INEX>WEATHERBOARD does not accelerate corrosion on class or higher metal fasteners & fixings. STANDARD Thermal Conductivity 0.9 W/m.K AS/NZS 9. R-Value at mm Thickness 0.09 m².k/w AS/NZS 9. R-Value (typical wall system). m.k/w Building Code of Australia Specification J. Assumes R. thermal insulation & 0mm plasterboard internal lining. Flammability Index 0 AS Ignitability Index 0 AS/NZS 0.:999 Spread of Flame Index 0 AS/NZS 0.:999 Heat Evolved Index 0 AS/NZS 0.:999 Smoke Developed Index AS/NZS 0.:999 Combustibility PASS - Not deemed Combustible AS clause. & AS/NZS :99 Building Code of Australia - Specification A. Bush Fire Attack Level BAL-0 PASS AS/NZS 0.. Bush Fire Attack Level BAL-FZ PASS AS & AS Asbestos PASS - Asbestos Free AS 9-00 Fungal Resistance PASS No growth ASTM C-0 VOC Emission Very Low (0.0mg/m /hr) ASTM D STANDARD / METHOD Technical Manual INEX BOARDS External Applications

38 INEX WEATHERBOARD Installation PRODUCT WEIGHT At approx. kg per length (mm) INEX>WEATHERBOARD is lightweight and easy to handle on site. STORAGE INEX>WEATHERBOARD should be stored dry, flat and with all edges protected from damage. We recommend storage undercover and raised from the ground. HANDLING Wear protective gloves when handling or cutting INEX>WEATHERBOARD. SUPPORT FRAMING INEX>WEATHERBOARD can be fixed to timber or steel studs with spacing at maximum 00mm centres. Timber framing must be in accordance with AS Residential timber-framed construction. Steel framing must be in accordance with AS Domestic metal framing. Ensure framing is plumbed prior to fitting. FIXING WALL SYSTEMS ASSEMBLY We recommend INEX>WEATHERBOARD be fitted to a staggered layout. With its tongue and groove ends it can be off-stud end jointed. Ensure framing and INEX>WEATHERBOARD are clean and dry prior to fitting. FIXINGS: Ensure all fixings are located: 0mm Min. from top edge of weatherboard ( no pre-drilling required ) mm Min. from tongue and groove joint when centering joint to stud to avoid any damage to the tongue and groove edges. FIXINGS TIMBER JOISTS Class Galvanised Fixings or higher* Screws: 0gx0mm self-embedding countersunk head screws. FIXINGS STEEL JOISTS Class Galvanised Fixings or higher* Screws: gx0mm self-drilling, self-embedding, countersunk head screws. *Class or Stainless Steel screws for sea spray zone in accordance with AS WALL SYSTEMS INEX>WEATHERBOARD can be installed in conjunction with a variety of lightweight wall systems and finished with a range of paint finishes or coatings. INEX>WEATHERBOARD can deliver a BAL-FZ* and/or a Fire Resistance Level ( FRL) of 0/0/0 without the need for any fire rated plasterboard or fire rated sealants. Refer to the following pages for further details of these fire rated systems for either timber or steel frames. * BAL-FZ (Flame Zone) is the highest Bushfire Attack Level where there is an extremely high risk of ember attack and burning debris ignited by windborne embers, and a likelihood of exposure to an extreme level of radiant heat and direct exposure to flames from the fire front. BAL-FZ FRL 0/0/0 INEX BOARDS External Applications Technical Manual

39 APPLICATION OF FINISHES The SMOOTH FINISH of INEX>WEATHERBOARD is an ideal surface to be finished with multiple proprietary paint systems available on the market. For surface preparation we recommend an acrylic primer sealer undercoat. Refer to the COATINGS menu on the UBIQ website. For designers wishing to achieve a timber-grain weatherboard look, the ROUGH SAWN FINISH of INEX>WEATHERBOARD provides a superb linear textured surface to attain this option or timber appearance. Details of timber-grain coating systems are available on UBIQ website. Refer to the COATINGS menu on UBIQ s website. INSULATION BATT VAPOUR PERMEABLE BUILDING WRAP INEX>WEATHERBOARD MAXIMUM STUD SPACING WIND CLASSIFICATION STUD SPACING Non-cyclonic Cyclonic General areas Within 00mm of building (mm) of building edges (mm) N, N, N C N, N C, C 00 0 N C 0 00 Stud spacings for INEX>WEATHERBOARD for the wind load classifications of AS 0 Wind Loads for Housing are given in the above table. FRL 0/0/0 FRAMING SYSTEMS BAL-FZ WALL SYSTEMS INEX>WEATHERBOARD must be fixed to either timber or light gauge steel framing at a maximum of 00mm centres. INEX>WEATHERBOARD is ideally suited for light-weight construction. It can be used as a fast-track cladding system during construction, thus resulting in both cost and time saving benefits. For home alterations or additions, INEX>WEATHERBOARD can be erected easily and fitted efficiently to achieve a stunning weatherboard cottage appearance. INEX>WEATHERBOARD wall system, even when applied directly to either a timber or steel frame has achieved an FRL of 0/0/0 when tested against the Australian Standard AS0.-00 and therefore is suitable for BAL-FZ construction in accordance with AS There is no fire rated plasterboards or fire rated sealants required for these systems, details of which are provided in this document. BAL-FZ SYSTEM IN TIMBER STUD FRAME AS AS BAL-FZ SYSTEM IN STEEL STUD FRAME AS AS Technical Manual INEX BOARDS External Applications 9

40 INEX WEATHERBOARD LAYING PATTERN INEX>WEATHERBOARD must be fitted in a staggered pattern to achieve the best surface and finish. Refer to Figure. TONGUE AND GROOVE JOINT Apply a mm to mm diameter bead of INEX>BOND to the tongue and groove joints along the short ends of INEX>WEATHERBOARD. Refer to Figures &. GROOVE TONGUE Figure INEX>BOND CORNER TRIMS When installing INEX>WEATHERBOARD, corner trims must be fixed in accordance with trim manufacturer's instructions. INTERNAL CORNER TRIM DETAIL DOUBLE STUDS Figure GROOVE TONGUE APPROVED FLASHING TO REQUIREMENTS VAPOUR PERMEABLE BUILDING WRAP CONTINUOUS CONTINOUS AROUND AROUND CORNER CORNER Figure INEX>WEATHERBOARD mm BEAD OF INEX>BOND SEALANT DESIGN PINE SIMILAR DETAIL FOR BUSH FIRE ZONES AVAILABLE ON REQUEST Figure STARTER TRIMS INEX>STARTERTRIM (Product Code: IST0) must be used when installing the first row of INEX>WEATHERBOARD. See Detail of Figure COVERAGE 0 WIDTH COVERAGE 0 WIDTH EXTERNAL CORNER TRIM DETAIL TIMBER STUD VAPOUR PERMEABLE BUILDING WRAP INEX>WEATHERBOARD VAPOUR PERMEABLE BUILDING WRAP CONTINUOUS CONTINOUS AROUND AROUND CORNER CORNER mm BEAD OF INEX>BOND SEALANT DESIGN PINE EXTERNAL CORNER MOULD Figure APPROVED FLASHING TO REQUIREMENTS INEX>STARTERTRIM 000 x 0 x mm (DETAIL ) BOARD COVERAGE types of coverage are available for INEX>WEATHERBOARD: For 0mm wide board, coverage = 0mm For 0mm wide board, coverage = mm Figure SIMILAR DETAIL FOR BUSH FIRE ZONES AVAILABLE ON REQUEST 0 INEX BOARDS External Applications Technical Manual

41 INSTALLATION EQUIPMENT UBIQ recommends the following equipment and accessories for the installation of INEX>WEATHERBOARD: GENERAL: CUTTING: SCREW FIXING: INEX>WEATHERBOARD can be machined and worked in same way as comparable fibre cement weatherboard. INEX>WEATHERBOARD should be cut using a mechanical dust reducing circular saw with a diamond edge blade, similar to that used to cut softer brick or stone or the ones specifically used to cut fibre cement weatherboard. See also Health & Safety section below. INEX>WEATHERBOARD must be screw fixed only. Use a cordless power drill. DUST LIMITATION: Always limit dust with a vacuum dust extraction system with a suitable filter. Important Notes: Ensure all components are compatible with each other and suitable for INEX>WEATHERBOARD and/or the intended surface finish. Failure to install, finish or maintain this product in accordance with relevant building codes, regulations, standards and UBIQ s current published instructions may lead to personal injury, affect system performance, violate local building codes, and possibly void the product warranty. HEALTH & SAFETY UBIQ advises that INEX>WEATHERBOARD contains fiberglass reinforcing and causes fine dust when cutting or machining. Continuous or excessive inhalation of fine dust containing fiberglass particles can cause irritation and may cause lung scarring (silicosis). This dust could be carcinogenic as all dust may be. Exposure to such dust may cause irritation to the skin or other body surfaces. When cutting INEX>WEATHERBOARD use methods recommended in this brochure to minimise dust production, and in addition: LOCATION: Do not cut INEX>WEATHERBOARD indoors. Cut in a well ventilated outdoor location. CLOTHING, MASK & GOGGLES: Always wear protective clothing and properly fitted and approved mask (respirator) and eye protective goggles. DUST LIMITATION: Always use a mechanical circular saw equipped with a fitted dust extraction system. When cutting is finished always vacuum up residual dust. Maintain the work area as a dust free environment. Note: Due to the cementitious nature of INEX>BOARDS some superficial pin-holing may occur. The smooth side of INEX>WEATHERBOARD is characterised as a Class concrete finish. Technical Manual INEX BOARDS External Applications

42 INEX BOARDS External Applications Technical Manual

43 INEX WEATHERBOARD Typical Assembly Details The following pages show the common junctions of INEX>WEATHERBOARD assembly on either timber or steel framing with other building elements, such as framed or concrete floors and intersections of walls. Important considerations with respect to choice of edge and corner detailing surround; desired appearance and/or required fire rated performance. BAL-FZ and/or FRL CONSIDERATION It is important to note that INEX>WEATHERBOARD when installed with a minimum R. insulation delivers a default BAL-FZ and/or FRL 0/0/0 fire rating, and that this performance does NOT require the additional installation of any fire rated plasterboards. To achieve this performance, appropriate corner and edge detailing must be installed such detailing is included in the following pages. FRAME TIMBER STEEL INSULATION WITHIN FRAME MINIMUM R. MINIMUM R. BUSHFIRE ATTACK LEVEL (BAL) or FIRE RESISTANCE LEVEL (FRL) BAL-FZ or 0/0/0 ( x BAL-FZ) CORNER TRIM SELECTION INEX>WEATHERBOARD can be installed with a variety of proprietary external or internal corner trims such detailing is included in the following pages. Technical Manual INEX BOARDS External Applications

44 INEX WEATHERBOARD Timber Frame System: FRL 0/0/0 & BAL-FZ Timber stud at Max. 00mm centres to AS/NZS:00 Minimum. Glasswool or Rockwool insulation mm or 90mm thick Option for any breathable wall wrap INEX>WEATHERBOARD 0 or 0 with T&G butt joins off or on the stud 0mm thick standard grade plasterboard or equivalent INEX>STARTERTRIM Notched profile for easy and level fixing Achieves FRL 0/0/0 when tested to AS0.-00 Meets AS Section 9 (BAL-FZ) via testing to AS0.-00 INEX BOARDS External Applications Technical Manual

45 WEATHERBOARD BAL-FZ & FRL 0/0/0 TIMBER FRAME WEATHERBOARD BAL-FZ & FRL 0/0/0 TIMBER FRAME STUD STUD JOINS OFF or ON STUD DO NOT REQUIRE FIRE RATED SEALANT STUD STUD JOINS OFF or ON STUD DO NOT REQUIRE FIRE RATED SEALANT MAX 00 EXT CNR EXT CNR MAX 00 FIX CORNER TRIMS AT MAX. 0mm VERTICAL CENTRES INT CNR INT CNR FIX CORNER TRIMS AT MAX. 0mm VERTICAL CENTRES INEX>WEATHERBOARD 0 or 0 ANY SARKING BREATHABLE OR BUILDING WALL WRAP PAPER TIMBER STUD FRAME MIN. R. GLASSWOOL OR ROCKWOOL 0mm PLASTERBOARD OR SIMILAR INEX>STARTERTRIM 0mm x mm INEX>STARTERTRIM MITRED PROPRIETARY OR BUTT JOINED CORNER CUT FLASHING INEX (TRIM (TRIM FROM FROM WEATHERBOARD) WEATHERBOARD) NOTE: PROPRIETARY REFER ALSO TO CORNER INEX>WEATHERBOARD FLASHING TECHNICAL & INSTALLATION SHEET FOR FIXING DETAILS NOTE: REFER ALSO TO INEX>WEATHERBOARD TECHNICAL & INSTALLATION SHEET FOR FIXING DETAILS Technical Manual INEX BOARDS External Applications

46 INEX WEATHERBOARD Timber Frame Assembly Details FRL 0/0/0 and/or BAL-FZ Corners PLAN mm SEALED GAP (TYP) PLAN NON- LOADBEARING STUD PLAN mm SEALED GAP (TYP) PLAN TIMBER FRAME ASSEMBLY DETAILS MITRED OR BUTT JOINED CUT INEX> (trim from INEX>WEATHERBOARD) BAL-FZ ONLY CORNER OPTION INEX>BOND, OR OTHER PAINTABLE POLYURETHANE FLEXIBLE SEALANT ON BACKING ROD (or proprietary fire sealant if FRL required) INEX>BOND, OR OTHER PAINTABLE POLYURETHANE FLEXIBLE SEALANT ON BACKING ROD (or proprietary fire sealant if FRL required) FRL 0/0/0 and/or BAL-FZ CORNERS PROPRIETARY EXTERNAL CNR (James Hardie Linea aluminium external slimline boxed corner) INEX>WEATHERBOARD 0 or 0 ANY BREATHABLE WALL WRAP TIMBER STUD FRAME INSULATION (Min. R. required to deliver FRL 0/0/0) MITRED OR BUTT JOINED CUT INEX> (trim from INEX>WEATHERBOARD) BAL-FZ Only FRL Corner 0/0/0 Optionand/or BAL-FZ CORNERS NON- LOADBEARING STUD PLAN PLAN EXPANSION JOINT EXPANSION JOINT CONTINUOUS HARDWOOD PACKER. Min 0Kg/m HARDWOOD and/or BAL-0 approved species PROPRIETARY INTERNAL CNR (James Hardie Linea aluminium internal corner mould) BAL-FZ ONLY CORNER OPTION EXPANSION JOINT CONTINUOUS HARDWOOD PACKER. Min 0Kg/m HARDWOOD and/or BAL-0 approved species 0mm PLASTERBOARD OR SIMILAR 0mm x mm INEX>STARTERTRIM g Min. Class GALVANISED COUNTER SINKING SCREWS PROPRIETARY CORNER FLASHING NON- LOADBEARING STUDS NON- LOADBEARING STUDS INEX BOARDS External Applications Technical Manual

47 NON-FRL or NON-FRL BAL-FZ Corner BAL-FZ Options CORNER OPTIONS mm SEALED GAP (TYP) TIMBER TIMBER TIMBER EXTERNAL CORNER TRIM (for mm thick weatherboards) TIMBER INTERNAL CORNER TRIM (for mm thick weatherboards) FIBRE CEMENT FIBRE CEMENT mm SEALED GAP (TYP) PROPRIETARY FIBRE CEMENT EXTERNAL CORNER (James Hardie Scyon Axent Trim mm x mm) PROPRIETARY FIBRE CEMENT INTERNAL CORNER (James Hardie Scyon Axent Trim mm x mm) METAL ANGLE METAL ANGLE PROPRIETARY EXTERNAL CNR (James Hardie Linea aluminium external slimline boxed corner) PROPRIETARY INTERNAL CNR (James Hardie Linea aluminium internal corner mould) MITRE or NOTCH/SCRIBE NOTCH/SCRIBE CUT COMPOUND ANGLE TO BOARDS & PRIME ENDS AND JOIN WITH SEALANT Note: Proprietary Corner Soaker is also available for 0 wide boards. (James Hardie Linea 0mm corner soaker) NOTCH AND SCRIBE BOARDS SEQUENTIALLY OVER EACH OTHER & SEAL JOINTS BETWEEN BOARDS Technical Manual INEX BOARDS External Applications

48 INEX WEATHERBOARD TIMBER FRAME ASSEMBLY DETAILS (Cont.) INEX>FLOOR JOIST INEX>FLOOR JOIST CONCRETE PAD FOOTING TIMBER FRAME ASSEMBLY DETAILS (Cont.) BEARER BEARER FFL FFL CONCRETE GROUND SLAB CONCRETE GROUND SLAB MIN mm MIN mm CONCRETE PAD FOOTING WALL ON BEARERS WALL ON BEARERS WALL ON BEARERS INEX>FLOOR PROPRIETARY PVC STARTER TRIM (for mm thick fibre cement weatherboards) IF FRL REQUIRED (see details below) PROPRIETARY PVC STARTER TRIM (for mm thick fibre cement weatherboards) IF FRL REQUIRED (see details below) FFL WALL ON ON GND SLAB GND SLAB WALL ON GND SLAB INEX>FLOOR JOIST JOIST BEARER CONCRETE STRIP FOOTING (strip footing required BEARER for FRL) CONCRETE STRIP FOOTING (strip footing required for FRL) FRL OPTION FRL OPTION FRL OPTION INEX>WEATHERBOARD 0 or 0 INEX>WEATHERBOARD 0 or 0 ANY BREATHABLE WALL WRAP ANY BREATHABLE WALL WRAP TIMBER STUD FRAME INSULATION TIMBER STUD FRAME (Min. R. required to deliver FRL 0/0/0) INSULATION (Min. R. required to deliver FRL 0/0/0) FFL CONCRETE GROUND SLAB CONCRETE GROUND SLAB FRL OPTION FRL OPTION 0mm PLASTERBOARD OR SIMILAR 0mm PLASTERBOARD OR SIMILAR 0mm x mm INEX>STARTERTRIM 0mm x mm INEX>STARTERTRIM g Min. Class GALVANISED COUNTER SINKING SCREWS g Min. Class GALVANISED COUNTER SINKING SCREWS PROPRIETARY CORNER FLASHING PROPRIETARY CORNER FLASHING FRL OPTION MIN mm MIN mm INEX BOARDS External Applications Technical Manual

49 SELECTED METAL CAPPING NOTE: PARAPET WALL SHALL BE DESIGNED AN FASTENED IN ACCORDANCE WITH SAA -HB INSTALLATION CODE FOR METAL ROOFING AND WALL CLADDING. STOP ENDS SHALL BE INCORPARATED TO ALL FLASHINGS ROOF PARAPET PARAPET NOTE: FOR GABLE TYPE SITUATIONS, OR WHERE THE WALL IS TO A ROOF SPACE, THE INSULATION AND INTERNAL LINING CAN BE OMITTED FOR BAL-FZ ONLY (NOT FRL 0/0/0) FLASHING as required by window manufacturer ROOF SPACE (BAL-FZ ONLY) ROOF SPACE (BAL-FZ ONLY) PROPRIETARY FIBRE CEMENT TRIM or TIMBER TRIM / WINDOW ARCHITRAVE SEALANT mm SEALED GAP (TYP) CONTINUOUS BEAD OF JOINT SEALANT HEAD FLASHING as required by window manufacturer, or SEALANT PROPRIETARY FIBRE CEMENT TRIM or TIMBER TRIM / WINDOW ARCHITRAVE JAMB JAMB SILL SILL Technical Manual INEX BOARDS External Applications 9

50 INEX WEATHERBOARD Steel Frame System: FRL 0/0/0 & BAL-FZ Steel stud at Max. 00mm centres to AS/NZS 00:00 Minimum. Glasswool or Rockwool insulation mm or 90mm thick Option for any breathable wall wrap INEX>WEATHERBOARD 0 or 0 with T&G butt joins off or on the stud 0mm thick standard grade plasterboard or equivalent INEX>STARTERTRIM Notched profile for easy and level fixing Achieves FRL 0/0/0 when tested to AS0.-00 Meets AS Section 9 (BAL-FZ) via testing to AS INEX BOARDS External Applications Technical Manual

51 WEATHERBOARD BAL-FZ & FRL 0/0/0 STEEL FRAME WEATHERBOARD BAL-FZ & FRL 0/0/0 STEEL FRAME STUD STUD JOINS OFF or ON STUD DO NOT REQUIRE FIRE RATED SEALANT STUD JOINS OFF or ON STUD DO NOT REQUIRE FIRE RATED SEALANT STUD MAX 00 INEX>WEATHERBOARD 0 or 0 ANY BREATHABLE WALL WRAP STEEL STUD FRAME STEEL STUD FRAME EXT CNR INEX>WEATHERBOARD 0 or 0 ANY BREATHABLE WALL WRAP EXT CNR MIN. R. GLASSWOOL OR ROCKWOOL MIN. R. GLASSWOOL OR ROCKWOOL FIX CORNER TRIMS AT MAX. 0mm VERTICAL CENTRES MAX 00 FIX CORNER TRIMS AT MAX. 0mm VERTICAL CENTRES INT CNR INT CNR 0mm PLASTERBOARD OR SIMILAR 0mm PLASTERBOARD OR SIMILAR 0mm x mm INEX>STARTERTRIM 0mm x mm INEX>STARTERTRIM MITRED OR BUTT JOINED CUT INEX (TRIM MITRED FROM OR WEATHERBOARD) BUTT JOINED CUT INEX (TRIM FROM WEATHERBOARD) PROPRIETARY CORNER FLASHING PROPRIETARY CORNER FLASHING NOTE: REFER ALSO TO INEX>WEATHERBOARD TECHNICAL NOTE: REFER & INSTALLATION ALSO TO INEX>WEATHERBOARD SHEET FOR FIXING DETAILS TECHNICAL & INSTALLATION SHEET FOR FIXING DETAILS Technical Manual INEX BOARDS External Applications

52 INEX WEATHERBOARD Steel Frame Assembly Details mm SEALED GAP (TYP) PLAN PLAN MITRED OR BUTT JOINED CUT INEX> (trim from INEX>WEATHERBOARD) EXPANSION JOINT EXPANSION JOINT INEX>BOND, OR OTHER PAINTABLE POLYURETHANE FLEXIBLE SEALANT ON BACKING ROD (or proprietary fire sealant if FRL required) INEX>WEATHERBOARD 0 or 0 ANY BREATHABLE WALL WRAP STEEL STUD FRAME INSULATION (Min. R. required to deliver FRL 0/0/0) 0mm PLASTERBOARD OR SIMILAR 0mm x mm INEX>STARTERTRIM g Min. Class GALVANISED COUNTER SINKING SCREWS PROPRIETARY CORNER FLASHING INEX BOARDS External Applications Technical Manual

53 NON-FRL Corner Options mm SEALED GAP (TYP) TIMBER TIMBER TIMBER EXTERNAL CORNER TRIM (for mm thick weatherboards) TIMBER INTERNAL CORNER TRIM (for mm thick weatherboards) FIBRE CEMENT FIBRE CEMENT mm SEALED GAP (TYP) PROPRIETARY FIBRE CEMENT EXTERNAL CORNER (James Hardie Scyon Axent Trim mm x mm) PROPRIETARY FIBRE CEMENT INTERNAL CORNER (James Hardie Scyon Axent Trim mm x mm) METAL ANGLE PROPRIETARY EXTERNAL CNR (James Hardie Linea aluminium external slimline boxed corner) PROPRIETARY INTERNAL CNR (James Hardie Linea aluminium internal corner mould) MITRE or NOTCH/SCRIBE CUT COMPOUND ANGLE TO BOARDS & PRIME ENDS AND JOIN WITH SEALANT Note: Proprietary Corner Soaker is also available for 0 wide boards. (James Hardie Linea 0mm corner soaker) NOTCH AND SCRIBE BOARDS SEQUENTIALLY OVER EACH OTHER & SEAL JOINTS BETWEEN BOARDS Technical Manual INEX BOARDS External Applications

54 STEEL FRAME ASSEMBLY DETAILS (Cont.) INEX WEATHERBOARD INEX>FLOOR PURLIN PURLIN INEX>FLOOR STEEL BEAM STEEL BEAM MS ANGLE MS ANGLE POST TO FOOTING POST TO FOOTING NOTE: U/S OF FLOOR STRUCTURE NOT SHOWN TO FRL PERFORMANCE. NOTE: IF REQUIRED, SPECIFIER TO DETAIL U/S OF FLOOR STRUCTURE NOT SHOWN ACCORDINGLY. TO FRL PERFORMANCE. IF REQUIRED, SPECIFIER TO DETAIL ACCORDINGLY. WALL ON FRAME WALL ON FRAME ON FRAME FFL CONCRETE GROUND SLAB PROPRIETARY PVC STARTER TRIM (for mm thick fibre cement weatherboards) IF FRL REQUIRED (see details below) PROPRIETARY PVC STARTER TRIM or (for mm thick fibre cement weatherboards) INEX>STARTERTRIM IF FRL REQUIRED IF FRL REQUIRED (see details below) or INEX>STARTERTRIM IF FRL REQUIRED FFL FFL FFL CONCRETE GROUND SLAB MIN mm WALL ON WALL GND ON SLAB GND SLAB WALL ON GND SLAB MIN mm CONCRETE GROUND SLAB FRL OPTION FRL FRL OPTION CONCRETE GROUND SLAB MIN mm MIN mm INEX>WEATHERBOARD 0 or 0 INEX>WEATHERBOARD 0 or 0 ANY BREATHABLE WALL WRAP ANY BREATHABLE WALL WRAP STEEL STUD FRAME STEEL STUD FRAME INSULATION (Min. R. required to deliver FRL 0/0/0) INSULATION (Min. R. required to deliver FRL 0/0/0) 0mm PLASTERBOARD OR SIMILAR 0mm 0mm PLASTERBOARD x mm INEX>STARTERTRIM OR SIMILAR 0mm g Min. x mm Class INEX>STARTERTRIM GALVANISED COUNTER SINKING SCREWS g Min. Class GALVANISED COUNTER SINKING PROPRIETARY SCREWS CORNER FLASHING PROPRIETARY CORNER FLASHING INEX BOARDS External Applications Technical Manual

55 SELECTED METAL CAPPING NOTE: PARAPET WALL SHALL BE DESIGNED AN FASTENED IN ACCORDANCE WITH SAA -HB INSTALLATION CODE FOR METAL ROOFING AND WALL CLADDING. STOP ENDS SHALL BE INCORPARATED TO ALL FLASHINGS ROOF PARAPET PARAPET NOTE: FOR GABLE TYPE SITUATIONS, OR WHERE THE WALL IS TO A ROOF SPACE, THE INSULATION AND INTERNAL LINING CAN BE OMITTED FOR BAL-FZ ONLY (NOT FRL 0/0/0) FLASHING as required by window manufacturer ROOF SPACE (BAL-FZ ONLY) ROOF SPACE (BAL-FZ ONLY) PROPRIETARY FIBRE CEMENT TRIM or TIMBER TRIM / WINDOW ARCHITRAVE SEALANT mm SEALED GAP (TYP) CONTINUOUS BEAD OF JOINT SEALANT HEAD FLASHING as required by window manufacturer, or SEALANT PROPRIETARY FIBRE CEMENT TRIM or TIMBER TRIM / WINDOW ARCHITRAVE JAMB SILL SILL Technical Manual INEX BOARDS External Applications

56 INEX BOARDS External Applications Technical Manual

57 INEX EXPRESS Technical Manual INEX BOARDS External Applications

58 INEX EXPRESS Product Information PRODUCT LENGTH (mm) WIDTH (mm) THICKNESS (mm) Kg/m Kg/Sheet INEX>EXPRESS INEX>EXPRESS INEX>EXPRESS is a unique engineered cementitious composite Tongue and Groove (T&G) facade panel suitable for residential and commercial applications. The textured surface of INEX>EXPRESS provides a superb surface for a wide range of approved coating systems. INEX>EXPRESS is facade by the sheet and comes with grooves routed into its surface to deliver an authentic timber board appearance without the fuss of having to lay individual decking boards. Each INEX>EXPRESS sheet represents x 0mm wide individual timber boards, thereby cutting the installation time to less than 0% of what it would be if individual boards were used. INEX>EXPRESS is supplied already coated with the first coats of your selected stain. Only a final single coat is required after installation. BAL-FZ FRL 0/0/0 WEIGHT At Approx. 0kg or kg per sheet INEX>EXPRESS is relatively light weight and easy to handle on site. HIGH PERFORMANCE INEX>EXPRESS can be cut and worked just like comparable fibre cement sheets, but offers improved bending strength characteristics and finish quality. INEX>EXPRESS spans over frame supports at maximum 00mm centres. FRL, BAL-FZ & NON-COMBUSTIBILTY INEX>EXPRESS is non-combustible and is approved for all Bushfire Attack Levels including BAL-FZ*, and is certified to a Fire Rating Level (FRL) of 0/0/0. *BAL-FZ (Flame Zone) is the highest Bushfire Attack Level where there is an extremely high risk of ember attack and burning debris ignited by windborne embers, and a likelihood of exposure to an extreme level of radiant heat and direct exposure to flames from the fire front. MATERIAL INEX>EXPRESS is an advanced high strength, low carbon fibre reinforced Engineered Cementitious Composite (ECC) product, containing 0% of post industrial recycled materials and is toxin free. DURABILITY INEX>EXPRESS is highly durable and represents a real alternative to natural or composite timbers. INEX>EXPRESS can be coated to achieve the timber look, without the ongoing maintenance issues of natural timber. INEX BOARDS External Applications Technical Manual

59 SUPERIOR FINISH UBIQ s unique textured surface allows for complete flexibility of finishes; from an authentic natural timber appearance to a multitude of other staining and painting options. If a real natural timber appearance is desired then this can be readily achieved with a reduction of the long term maintenance issues of timber itself. Refer to the COATINGS menu on UBIQ s website for information regarding approved coating systems. VALUE INEX>EXPRESS is an affordable substitute to hardwood and / or other timber composites. Each INEX>EXPRESS represents x 0mm wide individual decking boards, thereby cutting the installation time to 0% of what it would be if individual boards were used. Critically INEX>EXPRESS sheets form the walls themselves and can be fitted onto a steel or timber frame. As such they are not a cosmetic addition to a finished wall as is the case with other such products delivering a similar appearance. Tongue & Groove joint between sheets INEX>EXPRESS in the raw. MOISTURE RESISTANCE INEX>EXPRESS is moisture resistant and retains its structural integrity when subjected to multiple soak/dry cycles in accordance with clause.. of AS/NZS Cellulose-cement products Part : Flat sheets. LOW CARBON INEX>EXPRESS is a low carbon product containing about 0% of the embodied energy of equivalent portland cement derived products, containing 0% of post industrial recycled materials. It is 00% recyclable. ASBESTOS AND TOXIN FREE INEX>EXPRESS does not contain any toxins and is asbestos free. MOULD & TERMITE RESISTANCE INEX>EXPRESS is resistant to mould and termite attack. INEX>EXPRESS installed and coated Note: UBIQ s concrete is a natural product and UBIQ sees it as such, with all its vital signs and characteristics. Each INEX>EXPRESS sheet is regarded as a single piece, just like natural timber. Efflorescences or small, visible pores or patches are not defects. They add to the character of the final finished and stained product. Differences in the surface appearance, which do not affect the fit for purpose of the panels, are permitted. The surface is not homogenous and the variations and texture are what deliver the remarkable appearance once these coatings are applied. They are what set these sheets apart from other composite decking products. Technical Manual INEX BOARDS External Applications 9

60 INEX EXPRESS Physical Properties INEX>EXPRESS is an advanced high strength, fibre reinforced Engineered Cementitious Composite (ECC) product, containing 0% of post-industrial recycled materials. INEX>EXPRESS is suitable for domestic and commercial applications and is manufactured to conform to the following requirements and standards. DIMENSIONAL AND GEOMETRICAL CHARACTERISTICS GEOMETRICAL TESTS EQUILIBRIUM CONDITION STANDARD Length, Width, Thickness, Straightness PASS AS/NZS 90. PHYSICAL CHARACTERISTICS APPARENT DENSITY TEST kg/m³ STANDARD mm INEX>EXPRESS AS/NZS Clause.. - test method.. Condition: Mass determined by drying out the test specimens in a ventilated oven maintained at 00 C for hrs. STRENGTH CHARACTERISTIC TYPE TEST DURABILITY, MOISTURE RESISTANCE AND CORROSION CHARACTERISTIC TYPE TEST THERMAL PROPERTIES CHARACTERISTIC TYPE TEST STANDARD Bending Strength (Mean) >MPa AS/NZS Clause. - test method.. Modulus of Elasticity >0GPa AS STANDARD Water Permeability PASS AS/NZS clause. - test method.. Frost Resistance PASS AS/NZS clause. - test method.. Heat-rain PASS AS/NZS clause. - test method B. Soak-dry PASS AS/NZS clause. - test method.. Corrosion Corrosion Tests undertaken by SGS Australia Pty. Ltd. demonstrate that INEX>EXPRESS does not accelerate corrosion on stainless steel fasteners & fixings. STANDARD Thermal Conductivity 0.9 W/m.K AS/NZS 9. R-Value at mm Thickness 0.09 m².k/w AS/NZS 9. R-Value (typical wall system). m.k/w Building Code of Australia Specification J. Assumes R. thermal insulation, minimum mm cavity & 0mm plasterboard internal lining. Flammability Index 0 AS Ignitability Index 0 AS/NZS 0.:999 Spread of Flame Index 0 AS/NZS 0.:999 Heat Evolved Index 0 AS/NZS 0.:999 Smoke Developed Index AS/NZS 0.:999 Combustibility PASS - Not deemed Combustible AS clause. AS/NZS :99 Building Code of Australia - Specification A. OTHERS MATERIAL TEST STANDARD / METHOD Asbestos PASS - Asbestos Free AS 9-00 Fungal Resistance PASS No growth ASTM C-0 VOC Emission Very Low (0.0mg/m /hr) ASTM D 0 INEX BOARDS External Applications Technical Manual

61 INEX EXPRESS Typical Assembly Details The following pages show the common junctions of INEX>EXPRESS assembly on either timber or steel framing with other building elements, such as framed or concrete floors, and intersections of walls. Important considerations with respect to choice of framing surround the choice of battens, as follows: BATTEN SELECTION In all cases INEX>EXPRESS must be installed with a frame with a cavity batten system. This best practice framed wall system allows INEX>EXPRESS to breath and will minimise long term future issues such a water penetration. Battens can be laid to a vertical or horizontal orientation on the face of the studs depending upon the desired orientation of the boards. They can be either timber or steel. Importantly, this cavity system can deliver a Fire Resistance Level (FRL) or Bushfire Attack Level (BAL) to the wall systems, the FRL or BAL rating of which is determined by the choice of batten. The table below describes the FRL or BAL outcomes achieved by choice of framing and/or batten. FRAME TIMBER STEEL BATTEN VERTICAL MIN mm MIN mm (Furring channel) 0/0/0 (BAL-FZ) 0/0/0 (and/or BAL-FZ) BATTEN HORIZONTAL TIMBER FRL or BAL STEEL FRL or BAL MIN mm* (Top Hat) 0/0/0 (and/or BAL-FZ) *Depth of top hat will be subject to wind load criteria and structural design of the overall frame. Technical Manual INEX BOARDS External Applications

62 INEX EXPRESS Vertical Expression EXP. JOINT AT EACH SHEET OR STOREY SINGLE SHEET BEAD OF INEX>BOND AT EACH BEAD VERTICAL OF INEX>BOND TONGUE & GROOVE AT EACH JOINT VERTICAL TONGUE & GROOVE JOINT EXP. JOINT AT EACH SHEET OR STOREY SHEET LENGTH 00mm or 000mm VERTICAL EXPANSION JOINTAT Max..m CENTRES (9 SHEETS) OR AS OTHERWISE REQUIRED HORIZONTAL BATTENS & VERTICAL EXPRESSION Horizontal Expression SHEET LENGTH 00mm or 000mm EXP. JOINT AT EACH STOREY TONGUE FACING UP AND BEAD OF INEX>BOND AT ALL HORIZONTAL JOINS SHEET WIDTH 00mm SINGLE SHEET EXP. JOINT AT EACH STOREY VERTICAL EXPANSION JOINT AT EACH SHEET OR AS OTHERWISE REQUIRED VERTICAL BATTENS & HORIZONTAL EXPRESSION INEX BOARDS External Applications Technical Manual

63 Technical Manual INEX BOARDS External Applications

64 INEX EXPRESS ASSEMBLY DETAILS - EXPRESS HORIZONTAL Assembly Details Express Horizontal mm FURRING CHANNEL DRAWN Min. mm COLORBOND EQUAL ANGLE. - FIX TO INSIDE OF FIRST BOARD INTO CNR PRIOR TO FIX OF BOARD. PLAN CAVITY FRL 0/0/0 COLOUR MATCHED OR PAINTED FLEXIBLE SEALANT (or proprietary fire sealant if FRL required) CDS ALUMINIUM EXTERNAL CORNER TRIM (From CSR Cementel Designer Series) DOUBLE STUD AT JOINT VERTICAL JOINT CDS DOUBLE FLANGE ALUMINIUM JOINT BACKING STRIP WITH COLOUR MATCHED OR PAINTED FLEXIBLE SEALANT (From CSR Cementel Designer Series) (or proprietary fire sealant if FRL required) INEX>EXPRESS (horizontal) Grooved rough side facing outwards MIN mm METAL BATTEN (delivers FRL 0/0/0) mm STEEL FURRING CHANNEL, on PROPRIETARY FIXING CLIPS SUCH AS:- - RONDO 9mm #9 or mm #0 FIXED WITH RONDO # CLIP ANY BREATHABLE WALL WRAP TIMBER OR STEEL STUD FRAME (BOTH DRAWN) ANY INSULATION 0mm PLASTERBOARD OR SIMILAR 0mm LONG 0 GUAGE MIN Class GALV. COUNTER SINKING SCREWS (FILL BEFORE FINAL COAT OF STAIN) INEX BOARDS External Applications Technical Manual

65 Assembly Details Express Horizontal GROOVES IN INEX>EXPRESS OMITTED FOR CLARITY 0 SCREWS LOCATED IN GROOVES AND COUNTER SUNK SCREW LOCATED IN CENTRE POINT AND COUNTER SUNK DOUBLE STUD AT ENDS OF BOARDS, OR OTHER VERTICAL JOINTS TONGUE FACING UP (SEAL WITH INEX>BOND DURING ASSEMBLY) 0 0 +mm STUD SET OUT ALLOWANCE FOR VERTICAL JOINT DETAIL CDS DOUBLE FLANGE ALUMINIUM JOINT BACKING STRIP WITH COLOUR MATCHED OR PAINTED FLEXIBLE SEALANT (From CSR Cementel Designer Series) (or proprietary fire sealant if FRL required) FIXING NOTES: FIXING NOTES: - IF EXPRESSED SCREWS ARE DESIRED THESE MUST BE STAINLESS STEEL IF EXPRESSED SCREWS ARE DESIRED THESE MUST BE STAINLESS STEEL - COUNTERSUNK SCREWS CAN BE CLASS GALVANISED OR HIGHER. COUNTER COUNTERSUNK SINK THESE SCREWS SCREWS CAN BE TO CLASS A DEPTH GALVANISED SUFFICIENT OR TO HIGHER. FILL WITH NON-SHRINK EXTERNAL GRADE PATCHING COMPOUND AND COAT OVER WITH COUNTER FINAL SINK COAT THESE OF SELECTED SCREWS TO STAIN. A DEPTH SUFFICIENT TO FILL WITH NON-SHRINK EXTERNAL GRADE PATCHING COMPOUND AND COAT OVER WITH FINAL COAT OF SELECTED STAIN. - CONCEALED M TAPE FIXING. CONCEALED M TAPE FIXING. SUBJECT TO WIND LOADING REQUIREMENTS DOUBLE SIDED VHB TAPE FROM M Industrial Adhesives CAN BE USED AS AN ALTERNATIVE TO SCREWS. REFER SUBJECT TO UBIQ TO WIND FOR LOADING DETAILS REQUIREMENTS OF M TAPE FIXING DOUBLE SIDED VHB TAPE FROM M Industrial Adhesives CAN BE USED AS AN ALTERNATIVE TO SCREWS. REFER TO UBIQ FOR DETAILS OF M TAPE FIXING Technical Manual INEX BOARDS External Applications

66 ASSEMBLY DETAILS - EXPRESS HORIZONTAL INEX EXPRESS mm FURRING CHANNEL DRAWN INEX>FLOOR FFL PURLIN BEAM CONCRETE GROUND SLAB MIN mm MS ANGLE POST TO FOOTING NOTE: U/S OF FLOOR STRUCTURE NOT SHOWN TO FRL PERFORMANCE. IF REQUIRED, SPECIFIER TO DETAIL ACCORDINGLY. WALL ON FRAME CDS STARTER TRIM FIXED AT 0mm CENTRES (From CSR Cementel Designer Series). PART REMOVE INNER TONGUE FOR KEY IF FRL REQUIRED:- - Install fire stop or - Locate concrete edge mm behind INEX>EXPRESS (see detail below) FFL WALL ON ON GND SLAB METAL FLASHING mm GAP TO FACE OF CONCRETE MIN mm FRL OPTION INEX>EXPRESS (horizontal) Grooved rough side facing outwards MIN mm METAL BATTEN (delivers FRL 0/0/0) mm STEEL FURRING CHANNEL, on PROPRIETARY FIXING CLIPS SUCH AS:- - RONDO 9mm #9 or mm #0 FIXED WITH RONDO # CLIP ANY BREATHABLE WALL WRAP TIMBER OR STEEL STUD FRAME (STEEL DRAWN) ANY INSULATION 0mm PLASTERBOARD OR SIMILAR 0mm LONG 0 GUAGE MIN Class GALV. COUNTER SINKING SCREWS (FILL BEFORE FINAL COAT OF STAIN) INEX BOARDS External Applications Technical Manual

67 ASSEMBLY DETAILS - EXPRESS HORIZONTAL SELECTED METAL CAPPING NOTE: PARAPET WALL SHALL BE DESIGNED AN FASTENED IN ACCORDANCE WITH SAA -HB INSTALLATION CODE FOR METAL ROOFING AND WALL CLADDING. STOP ENDS SHALL BE INCORPARATED TO ALL FLASHINGS NOM. 0mm x mm PRE-FINISHED ALUMINIUM FLASHING FIXED TO FACE OF FURRING CHANNELS PRIOR TO FIXING BOARDS FFL COLOUR MATCHED OR PAINTED FLEXIBLE SEALANT (or proprietary fire sealant if FRL required) ROOF PARAPET NOGGIN REMOVE TONGUE FROM LOWER SHEET PRIOR TO FIX HORIZONTAL JOINT JOINT (AT FLOOR JUNCTION, OR AS OTHERWISE RQRD). CONTINUOUS BEAD OF COLOUR MATCHED OR PAINTED FLEXIBLE SEALANT HEAD FLASHING as required by window manufacturer JAMB JAMB FLASHING as required by window manufacturer SILL MAXIMUM STUD SPACING WIND CLASSIFICATION STUD SPACING Non-cyclonic Cyclonic General areas Within 00mm of building (mm) of building edges (mm) N, N, N C N, N C, C 00 0 N C 0 0 Stud spacings for INEX>EXPRESS for the wind load classifications of AS 0 Wind Loads for Housing are given in the above table. Technical Manual INEX BOARDS External Applications

68 INEX EXPRESS Assembly Details Express Vertical BATTEN DRAWN AS mm HORIZONTAL TOP HAT Min. mm COLORBOND EQUAL ANGLE. - FIX TO INSIDE OF FIRST BOARD INTO CNR PRIOR TO FIX OF BOARD. PLAN CAVITY FRL 0/0/0 COLOUR MATCHED OR PAINTED FLEXIBLE SEALANT (or proprietary fire sealant if FRL required) CDS ALUMINIUM EXTERNAL CORNER TRIM (From CSR Cementel Designer Series) mm COLORBOND FLAT WITH HALF OF FLAT OVERLAPPING EDGE. - FIX TO INSIDE OF FIRST BOARD FIXED VERTICAL JOINT COLOUR MATCHED OR PAINTED FLEXIBLE SEALANT (or proprietary fire sealant if FRL required) INEX>EXPRESS (vertical) Grooved rough side facing outwards TIMBER OR STEEL STUD FRAME (STEEL DRAWN) Min. mm TOP HAT WITH TAPERED LEGS AT Max. 00mm VERTICAL CENTRES ANY INSULATION SUCH AS mm DEEP STUDCO M0 (0. BMT), or 0mm DEEP STUDCO TH0 (0. BMT) 0mm PLASTERBOARD OR SIMILAR ANY BREATHABLE WALL WRAP 0mm LONG 0 GUAGE MIN Class GALV. COUNTER SINKING SCREWS (FILL BEFORE FINAL COAT OF STAIN) INEX BOARDS External Applications Technical Manual

69 Assembly Details Express Vertical TOP HAT TOP HAT GROOVES IN INEX>EXPRESS OMITTED FOR CLARITY SCREWS LOCATED IN GROOVES AND COUNTER SUNK T&G JOINT TO INEX>EXPRESS (SEAL WITH INEX>BOND DURING ASSEMBLY) MAX 00 TOP HAT CENTRES SCREW LOCATED IN CENTRE AND COUNTER SUNK MAX 00 STUD FRAME MAX 00 STUD FRAME FIXING NOTES: FIXING NOTES: - IF EXPRESSED SCREWS ARE DESIRED THESE MUST BE STAINLESS STEEL IF EXPRESSED SCREWS ARE DESIRED THESE MUST BE STAINLESS STEEL - COUNTERSUNK SCREWS CAN BE CLASS GALVANISED OR HIGHER. COUNTERSUNK SCREWS CAN BE CLASS GALVANISED OR HIGHER. COUNTER SINK THESE SCREWS TO A DEPTH SUFFICIENT TO FILL WITH NON-SHRINK EXTERNAL GRADE PATCHING COMPOUND AND COAT OVER WITH COUNTER FINAL COAT SINK THESE OF SELECTED SCREWS STAIN. TO A DEPTH SUFFICIENT TO FILL WITH NON-SHRINK EXTERNAL GRADE PATCHING COMPOUND AND COAT OVER WITH FINAL COAT OF SELECTED STAIN. - CONCEALED M TAPE FIXING. CONCEALED M TAPE FIXING. SUBJECT TO WIND LOADING REQUIREMENTS DOUBLE SIDED VHB TAPE FROM M Industrial Adhesives CAN BE USED AS AN ALTERNATIVE TO SCREWS. SUBJECT TO WIND LOADING REQUIREMENTS DOUBLE SIDED VHB TAPE FROM M Industrial Adhesives CAN BE USED AS AN ALTERNATIVE TO SCREWS. REFER TO UBIQ FOR DETAILS OF M TAPE FIXING REFER TO UBIQ FOR DETAILS OF M TAPE FIXING Technical Manual INEX BOARDS External Applications 9

70 INEX EXPRESS ASSEMBLY DETAILS - EXPRESS VERTICAL INEX>FLOOR mm TOP HAT DRAWN FFL PURLIN BEAM CONCRETE GROUND SLAB MIN mm MS ANGLE WALL ON WALL ON GND SLAB GND SLAB POST TO FOOTING IF FRL REQUIRED:- - Install fire stop or - Locate concrete edge mm behind INEX>EXPRESS (see detail below) NOTE: U/S OF FLOOR STRUCTURE NOT SHOWN TO FRL PERFORMANCE. IF REQUIRED, SPECIFIER TO DETAIL ACCORDINGLY. WALL ON FRAME FFL METAL FLASHING mm GAP TO FACE OF CONCRETE MIN mm FRL OPTION FRL OPTION INEX>EXPRESS (vertical) Grooved rough side facing outwards Min. mm TOP HAT WITH TAPERED LEGS AT Max. 00mm VERTICAL CENTRES SUCH AS mm DEEP STUDCO M0 (0. BMT), or 0mm DEEP STUDCO TH0 (0. BMT) ANY BREATHABLE WALL WRAP TIMBER OR STEEL STUD FRAME (STEEL DRAWN) ANY INSULATION 0mm PLASTERBOARD OR SIMILAR g MIN Class GALVANISED COUNTER SINKING SCREWS - FILL BEFORE FINAL COAT 0 INEX BOARDS External Applications Technical Manual

71 SELECTED METAL CAPPING NOTE: PARAPET WALL SHALL BE DESIGNED AN FASTENED IN ACCORDANCE WITH SAA -HB INSTALLATION CODE FOR METAL ROOFING AND WALL CLADDING. STOP ENDS SHALL BE INCORPARATED TO ALL FLASHINGS ROOF PARAPET PARAPET mm COLORBOND FLAT WITH mm OVERLAP FROM BOARD BASE AND TERMINATING 0mm SHORT OF EACH EDGE. - FIX TO INSIDE OF UPPER BOARD PRIOR TO FIX OF BOARD. FFL COLOUR MATCHED OR PAINTED FLEXIBLE SEALANT (or proprietary fire sealant if FRL required) 0x0 COLORBOND FLASHING FIXED TO TOP HAT WITH WALL WRAP LIPPED OVER HORIZONTAL JOINT JOINT (AT FLOOR JUNCTION, OR AS OTHERWISE RQRD). CONTINUOUS BEAD OF COLOUR MATCHED OR PAINTED FLEXIBLE SEALANT HEAD FLASHING as required by window manufacturer JAMB JAMB FLASHING as required by window manufacturer SILL SILL MAXIMUM STUD SPACING WIND CLASSIFICATION STUD SPACING Non-cyclonic Cyclonic General areas Within 00mm of building (mm) of building edges (mm) N, N, N C N, N C, C 00 0 N C 0 0 Stud spacings for INEX>EXPRESS for the wind load classifications of AS 0 Wind Loads for Housing are given in the above table. Technical Manual INEX BOARDS External Applications

72 INEX EXPRESS Stain Colour Range INEX>EXPRESS is supplied with the first coats of a coat stain system already applied. Following installation of the panels the installer or builder then applies the final coat to complete the stain system. Prior to this final coat the applicator must fill all counter sunk screw holes with a grey non-shrink external grout or filling compound. The final coat can be applied with a brush or sponge laying off in the direction of the grain. During this final coat ensure all filled screw holes or exposed fixings are well coated to prevent moisture or surface water soaking into the board. Whilst intermittent soaking of the board will not affect its long term structural integrity it can cause a temporary darkening of the board around these areas until it has dried or evaporate out. STAIN SELECTION All stains are provided by Ultralast Coating Systems and are taken from their STAIN PLUS range of coatings. All Ultralast s products are water based acrylic and are classified as zero VOC. These systems have been tested by Ultralast and have been approved for use of the rough side of INEX>EXPRESS. Ultralast can be contacted at: Ultralast Coating Systems Unit / Cowpasture Road, Wetherill Park NSW The coating system is warranted by Ultralast for up to years between recoating, subject to normal wear and tear. YEARS PLUS YEARS WARRANTY The following pages describe some of the colours that can be achieved. Once you have made your selection it is as simple as ordering your colour selection by the number and name described, together with the quantity of sheets your project will need. The supply of the final coat of STAIN PLUS as required by your selected colour should be made directly through Ultralast Coating Systems. Image of stain as printed or viewed on screen will differ from actuals. Full size displays of all colours are available to view at UBIQ s Showroom in Auburn, NSW. INEX BOARDS External Applications Technical Manual

73 BLACKWASH SUNSHINE The Neutrals GREYWASH WHITEWASH 0 UTS GREYWASH 0 0 UTS BLACKWASH 0 0 UTS SUNSHINE 0 0 UTS GREYWASH 0 0 UTS BLACKWASH 0 UTS GREYWASH 0 UTS SUNSHINE 0 UTS GREYWASH 0 UTS GREYWASH 0 UTS WHITEWASH 0 UTS WHITEWASH 0 UTS WHITEWASH The Timbers WALNUT SYRUP MERBAU WEATHERED 0 UTS GREYWASH 0 0 UTS WALNUT 0 0 UTS SYRUP 0 0 UTS SYRUP 0 0 UTS WALNUT 0 UTS GREYWASH 0 UTS SYRUP 0 UTS GREYWASH 0 UTS TEAK 0 UTS GREYWASH 0 UTS SYRUP 0 UTS WHITEWASH ROSEWOOD TEAK OAK EUROPEAN OAK 0 UTS GREYWASH 09 0 UTS ROSEWOOD 0 0 UTS TEAK 0 UTS OAK 0 UTS ROSEWOOD 0 UTS GREYWASH 0 UTS TEAK 0 UTS WHITEWASH 0 UTS OAK 0 UTS GREYWASH 0 UTS OAK 0 UTS OAK Technical Manual INEX BOARDS External Applications

74 INEX BOND Product Information PRODUCT SIZE (ml) PACKAGING COVERAGE (linear metres) INEX>BOND Cartridge 90 per carton Approx m (mm bead) INEX>BOND Sausage 00 per carton Approx m (mm bead) MS Polymer elastic adhesive/sealant with a broad adhesion spectrum and high durability PRODUCT DESCRIPTION INEX>BOND is a high-quality, exterior-grade, multi-purpose, non-sag, paintable, one-part adhesive/sealant that cures on exposure to atmospheric moisture to form a durable elastomer. For use to seal joints that must accommodate movement,* in any structure, etc., in conjunction with recommended mechanical fixings (nails and screws). INEX>BOND will bond to many materials including most timbers, metals, metal primers and paint coatings (one and two-part systems), ceramics and many plastics. INEX>BOND can provide an elastic water, gas and dust proof seal to moving joints in many structures. TYPICAL APPLICATIONS The primary application is to seal the joints between INEX>FLOOR boards when used in wet areas such as bathrooms, toilets, laundries, kitchens, balconies and decks. To seal control joints in ceramic tiled floors in L shaped rooms, etc. In light foot traffic areas it can be used to bond INEX>FLOOR boards to timber or metal joists. Sealing joints in building facades, around door and window frames and other expansion joints. PRODUCT BENEFITS Adheres to many surfaces without primers* Bonds well to old well-cleaned INEX>BOND adhesive/sealant Permanently elastic Odour free Solvent free Non-corrosive Non-sagging in a 0mm wide joint Superior weatherability to polyurethane sealants and adhesives Resistant to: water, dilute inorganic acids and alkalis, aliphatic solvents, oils and greases* Many paint systems can be applied within 0 minutes to hours of application or sooner in some cases.* * Pre-testing advised. INEX BOARDS External Applications Technical Manual

75 Terraçade Austral Precast Auswest Timbers Austral Masonry Austral Bricks Bristile Roofing Products and brands available from Brickworks Building Products Brickworks Building Products is one of Australia s largest and most diverse building material manufacturers. Under the Brickworks Building Products umbrella are some of Australia s best known building materials brands. Our products include bricks, pavers, masonry blocks, retaining wall systems, precast concrete panels, concrete and terracotta roof tiles, timber products and specialised facade systems. With a broad product portfolio and manufacturing and sales facilities across Australia, Brickworks Building Products is uniquely placed to service the demands of the building industry. With over,00 staff across Australia and New Zealand, we pride ourselves on our commitment to product and service excellence and our leadership position. INEX>BOARDS Technical Manual INEX BOARDS External Applications

INEX RENDERBOARD INEX BOARDS FACADE SOLUTIONS. A single board for: Render Coat Finish Towelled Finish Painted Finish Clear Raw Concrete Finish

INEX RENDERBOARD INEX BOARDS FACADE SOLUTIONS. A single board for: Render Coat Finish Towelled Finish Painted Finish Clear Raw Concrete Finish FACADE SOLUTIONS A single board for: Render Coat Finish Towelled Finish Painted Finish Clear Raw Concrete Finish INEX BOARDS ANY BUILDING ANY SURFACE ANYWHERE INEX>RENDERBOARD is a durable, lightweight

More information

INEX BOARDS DECKING SOLUTIONS INEX DECKING INEX MAXIDECK ANY BUILDING ANY SURFACE ANYWHERE

INEX BOARDS DECKING SOLUTIONS INEX DECKING INEX MAXIDECK ANY BUILDING ANY SURFACE ANYWHERE INEX BOARDS ANY BUILDING ANY SURFACE ANYWHERE DECKING SOLUTIONS INEX DECKING INEX MAXIDECK INEX>DECKING & INEX>MAXIDECK s coating spectrum offers a tremendous array of design possibilities. INEX DECKING

More information

INEX MAXIDECK INEX BOARDS DECKING SOLUTIONS ANY BUILDING ANY SURFACE ANYWHERE

INEX MAXIDECK INEX BOARDS DECKING SOLUTIONS ANY BUILDING ANY SURFACE ANYWHERE INEX MAXIDECK DECKING SOLUTIONS INEX BOARDS ANY BUILDING ANY SURFACE ANYWHERE INEX>MAXIDECK is a unique Engineered Cementitious Composite (ECC) material; an advanced low carbon concrete developed by UBIQ

More information

Decking Applications INEX BOARDS ANY BUILDING ANY SURFACE ANYWHERE. Technical Manual

Decking Applications INEX BOARDS ANY BUILDING ANY SURFACE ANYWHERE. Technical Manual Decking Applications Technical Manual ANY BUILDING ANY SURFACE ANYWHERE INEX BOARDS 2 INEX BOARDS Decking Applications Technical Manual Contents INEX>DECKING Product Information 5 INEX>DECKING Physical

More information

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2 Contents BCA Codes 3 General 4 Fire Performances Thermal and Acoustic Insulation Wall Installation 4 Timber Frame Separation Walls 5 Steel Frame Separation Walls 6 External Fire Rated Walls 7 Floor Installation

More information

Internal Applications

Internal Applications Internal Applications Technical Manual ANY BUILDING ANY SURFACE ANYWHERE INEX BOARDS 2 INEX BOARDS Decking Internal Applications Technical Manual Contents INEX>WALLBOARD Product Information 6 INEX>PARTYWALL

More information

130mm CROATIA BOARD 180mm V-GROOVE

130mm CROATIA BOARD 180mm V-GROOVE Enjoy DecoClad s enduring beauty in the bush, by the beach or in full sun. Effortless to install and maintain, DecoClad is the ultimate in exterior cladding. Pairing aluminium s proven strength and durability

More information

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM FOCAL POINT RENDAPANEL TM CLADDING SYSTEM strength and durability SYSTEM INFORMATION & TECHNICAL SPECIFICATION V4 2002 Page 1 of 7 INTRODUCTION Monolithic Light Weight Cement Render Cladding RendaPanel

More information

PRODUCT OVERVIEW NOVEMBER NEW Secura flooring sizes on pages 23 and 25

PRODUCT OVERVIEW NOVEMBER NEW Secura flooring sizes on pages 23 and 25 PRODUCT OVERVIEW NOVEMBER 2013 NEW Secura flooring sizes on pages 23 and 25 1 Content page 2: page 6: page 10: page 14: page 18: page 22: page 24: page 27: page 28: Scyon overview Scyon Linea weatherboard

More information

excom (Expressed Panel Facade System) Primary top hat 160 x 35 x 1.0mm mm.

excom (Expressed Panel Facade System) Primary top hat 160 x 35 x 1.0mm mm. (Expressed Panel Facade System) is a versatile, glass fibre-reinforced recycled wood fibre and magnesium cement based cladding. Fabricated from a combination of recycled timber materials (50%), mineral

More information

Installation & Specification Manual Board Fixing

Installation & Specification Manual Board Fixing Installation & Specification Manual Board Fixing 4 th Ed. September 2014 Fac. 2/89 Somerset Road Campbellfield Melbourne, 3061 P. 03 9359 2336 F. 03 9359 9306 info@ezylite.com.au www.ezylite.com.au Ezy-Lite

More information

Exterior Wall Solutions Building Shell

Exterior Wall Solutions Building Shell A strong, water tight and thermally insulated building shell will ensure the buildings sustainability of usage over time. The Exterior Shell is the most important factor of protection to ensure that the

More information

2/ T F.

2/ T F. Installation Manual Head Office 2/89 Somerset Road Campbellfield Vic, 3061 T. 03 9359 2336 F. 03 359 9306 E-mail. info@ezylite.com.au www.ezylite.com.au P-01 Contents Page 01 Contents Page 02 Page 03 Page

More information

Pronto Panel Multi-Storey External Technical Manual. January Version 3.0

Pronto Panel Multi-Storey External Technical Manual. January Version 3.0 Pronto Panel Multi-Storey External Technical Manual January 2018. Version 3.0 Pronto Panel Technical Manual Contents Introduction Building with Pronto Panel 6 Benefits 7 System Information Compliance and

More information

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls. ( ) is a new and innovative system designed to provide high performance separating walls between units and apartments in low-rise residential and commercial projects. provides exceptional fire and acoustic

More information

INEX BOARDS INEX FLOOR FRL DOWN LIGHTWEIGHT FLOOR SYSTEMS ANY BUILDING ANY SURFACE ANYWHERE FRL 90/90/90 DOWN FRL 90/90/90 DOWN FRL 90/90/90 DOWN

INEX BOARDS INEX FLOOR FRL DOWN LIGHTWEIGHT FLOOR SYSTEMS ANY BUILDING ANY SURFACE ANYWHERE FRL 90/90/90 DOWN FRL 90/90/90 DOWN FRL 90/90/90 DOWN INEX BOARDS ANY BUILDING ANY SURFACE ANYWHERE FRL DOWN LIGHTWEIGHT FLOOR SYSTEMS FRL 90/90/90 DOWN FRL 90/90/90 DOWN FRL 90/90/90 DOWN INEX FLOOR INEX>FLOOR is a lightweight yet incredibly strong multi-purpose

More information

SCYon tm THE BUILDING MATERIAL OF THE FUTURE

SCYon tm THE BUILDING MATERIAL OF THE FUTURE SCYon tm THE BUILDING MATERIAL OF THE FUTURE SCYON22689_ProductCards_v4.indd 1 23/4/08 10:29:17 AM SCYON tm THE BUILDING MATERIAL OF THE FUTURE are available today with the introduction of a heavy-duty,

More information

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD. Cl/SfB 1 (4-) RJ7 1 1 1 July 2010 Cempanel BUILDING BOARD CEMENT PARTICLE BOARD Cempanel Class 0 cement particle board with excellent impact, fire and acoustic properties. Its durability, consistently

More information

A4/8 PS AW2324D Issue 10 May Permishield

A4/8 PS AW2324D Issue 10 May Permishield Insulation A4/8 PS AW2324D Issue 10 May 2018 Vapour-permeable INSULATION MEMBRANE 3-in-1 Insulation, thermal break and vapour-permeable sarking Helps achieve a 6-star house energy rating Fibre-free, non-allergenic,

More information

Installation Guide. HardieBreak Thermal Strip COMPONENTS

Installation Guide. HardieBreak Thermal Strip COMPONENTS Installation Guide HardieBreak Thermal Strip COMPONENTS Australia April 2018 Make sure your information is up to date. When specifying or installing James Hardie products, ensure you have the current installation

More information

Introduction. Applications. Everest Facade Advantages

Introduction. Applications. Everest Facade Advantages EVEREST FACADE Everest Façade with Endura Everest Industries Limited Introduction The Everest Commercial Facade System provides a versatile and durable façade which is suitable for an extensive range of

More information

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 GENERAL REQUIREMENTS 185 FRAMING 185 PLASTERBOARD LAYOUT 189 PLASTERBOARD FIXING 190 EXTERIOR

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

Cl/SfB 1 (4-) 1 RJ December 2018 (2) Cempanel. Cement Particle Board - Building board for external and internal applications

Cl/SfB 1 (4-) 1 RJ December 2018 (2) Cempanel. Cement Particle Board - Building board for external and internal applications Cl/SfB 1 (4-) 1 RJ7 1 1 December 2018 (2) Cempanel Cement Particle Board - Building board for external and internal applications Cempanel Class 0 cement particle board with excellent impact, fire and acoustic

More information

BAL FZ BUSHFIRE ROOFING, WALLS & EAVES

BAL FZ BUSHFIRE ROOFING, WALLS & EAVES Fire Crunch Australian Certified Building Solutions BAL FZ BUSHFIRE ROOFING, WALLS & EAVES MANUAL REF FCA BAL 001107 (BAL) 12.5, 19, 29, 40 AND FZ FLAME ZONE FIRE TESTED BY CSIRO NATA CERTIFIED NO METAL

More information

Vulcan Primed Cladding

Vulcan Primed Cladding Overview is created from thermally modified New Zealand plantation timber and factory pre-primed for optimal coating performance. The thermal modification process means has enhanced stability, reduced

More information

Plywood (untreated or H3 treated) must not be allowed to come in contact with soil.

Plywood (untreated or H3 treated) must not be allowed to come in contact with soil. Plyfloor Advantages Superior strength Stiffness of Plyfloor is nearly three times that of particle type boards of the same thickness. This means thinner Plyfloor panels are cost effective floor panels.

More information

For more information about performance, installation, warranties and warnings:

For more information about performance, installation, warranties and warnings: Accessories Description James Hardie Joint Sealant * General purpose, paintable, exterior grade polyurethane joint sealant. 20 per box, 300ml cartridge/600ml sausage. PC: 305534/305672 * Not to be used

More information

A4/8 PS AW2002 Issue 6 Sept Permishield

A4/8 PS AW2002 Issue 6 Sept Permishield Insulation A4/8 PS AW2002 Issue 6 Sept 2015 Vapour-permeable INSULATION MEMBRANE 3-in-1 Insulation, thermal break and vapour-permeable sarking Helps achieve a 6-star house energy rating Fibre-free, non-allergenic,

More information

Insulated Lightweight Cladding Systems

Insulated Lightweight Cladding Systems Issue C, 2017. Insulated Lightweight Cladding Systems * Cost Effective * Complete System Packages * Energy Efficient * 10 Year Guarantee 07 55 005 815 Why use Rhinoboard EPS Wall Panel System Rhinoboard

More information

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. SECTION D Wall Systems. Contents. SUBJECT Introduction Design Considerations Installation Components PAGE D2 D2 D4 D5 System Specifications Stud One Side Stud Both Sides Stud and Furring Channel Resilient

More information

Concrete Soffit Direct Fix

Concrete Soffit Direct Fix Installation Guide Concrete Soffit Direct Fix Recommended Pattern insulation boards may be installed in any pattern. The recommended pattern is a square-set pattern, for simplest and quickest configuration

More information

K18 Insulated Plasterboard

K18 Insulated Plasterboard Insulation A4/8 K18 AW2203 Issue 11 Sep 2017 K18 Insulated INSULATED DRY-LINING PLASTERBOARD FOR MECHANICAL FIXING Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation

More information

icore HR outperforms other building boards in many important ways including the following:

icore HR outperforms other building boards in many important ways including the following: icore HR is a new and innovative system designed to provide high performance separating walls between units and apartments in high-rise commercial projects. icore HR system provides exceptional fire and

More information

TECHNICAL DOCUMENT: SYSTEM INSTALLATION & CONSTRUCTION DETAILS

TECHNICAL DOCUMENT: SYSTEM INSTALLATION & CONSTRUCTION DETAILS MASTERWALL AUSTRALIA PTY LTD. 18-20 Cyber Loop, Dandenong South, Victoria, Australia EMAIL. sales@masterwall.com.au WEB. www.masterwall.com.au NATIONAL ENQUIRIES. (03) 9799 6565 FAX. (03) 8740 2180 TECHNICAL

More information

Hebel - Better for building in bushfire zones

Hebel - Better for building in bushfire zones Hebel - Better for building in bushfire zones BUILDING WITH HEBEL IN BUSHFIRE ZONES Bushfires are a fact of Australian life. When building in a bushfire zone, the most important consideration is the choice

More information

System. Size: 2750 x 260 x 28mm Effective Cover: 1 Board = 0.674m 2

System. Size: 2750 x 260 x 28mm Effective Cover: 1 Board = 0.674m 2 JANUARY 2012 KINGWOOD Cladding panel must be installed and maintained in accordance with applicable building codes, regulations, standards and KINGWOOD written application instructions Failure to do so

More information

The GlasRoc Shaftliner Type X advantage...

The GlasRoc Shaftliner Type X advantage... C e r t a i n T e e d SHAFTLINER F o r A r e a S e p a r a t i o n F i r e w a l l s Shaftliner S Type X for Area Separation GlasRoc Shaftliner is a specially formulated product for applications where

More information

BETTER FOR BUILDING IN BUSHFIRE ZONES

BETTER FOR BUILDING IN BUSHFIRE ZONES BETTER FOR BUILDING IN BUSHFIRE ZONES BUILDING WITH HEBEL IN BUSHFIRE ZONES Bushfires are a fact of Australian life. When building in a bushfire zone, the most important consideration is the choice of

More information

Hebel - Better for building in bushfire zones

Hebel - Better for building in bushfire zones Hebel - Better for building in bushfire zones BUILDING WITH HEBEL IN BUSHFIRE ZONES Bushfires are a fact of Australian life. When building in a bushfire zone, the most important consideration is the choice

More information

think eco WOOD BOARD Bahan Binaan KELASʻOʼ

think eco WOOD BOARD Bahan Binaan KELASʻOʼ think eco BOARD Bahan Binaan KELASʻOʼ Bahan Binaan KELASʻOʼ BS 476 : PART 6 : 1989 + A1 :2009 SustainableArchitecturalSolutions Green Sustainable Building Products or eco-friendly products refer to building

More information

A4/6 PS AW1551 Issue 4 Nov Permishield

A4/6 PS AW1551 Issue 4 Nov Permishield Insulation A4/6 PS AW1551 Issue 4 Nov 2013 Vapour-permeable INSULATION MEMBRANE 3-in-1 Insulation, thermal break and vapour-permeable sarking Helps achieve a 6-star house energy rating Fibre-free, non-allergenic,

More information

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10 CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES 283 Chapter 10 FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS 10.1 PLASTERWORK Workmanship i. All workmanship must be within the tolerances

More information

K-SERIES EXTERNAL INSULATION & FINISH SYSTEM_

K-SERIES EXTERNAL INSULATION & FINISH SYSTEM_ K-SERIES EXTERNAL INSULATION & FINISH SYSTEM_ > SUPER-HIGH PERFORMANCE > THERMAL RATING UP TO R4.0 > BUSHFIRE ATTACK LEVEL BAL 40 K-SERIES TECHNICAL DOCUMENT_ 27.03.2018 SYSTEM INSTALLATION & CONSTRUCTION

More information

Design Guide. HardieSmart Boundary Wall System (Class 1 & 10a) SYSTEMS FRL 60/60/60 FROM THE OUTSIDE. Rw R

Design Guide. HardieSmart Boundary Wall System (Class 1 & 10a) SYSTEMS FRL 60/60/60 FROM THE OUTSIDE. Rw R FRL 60/60/60 FROM THE OUTSIDE Rw 47-48 R 2.0-2.6 4.0-10 kn/m Design Guide HardieSmart Boundary Wall System (Class 1 & 10a) SYSTEMS Certificate CM20135 Australia October 2017 Make sure your information

More information

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation. SECTION B Steel Frame Wall Systems. Contents. SUBJECT Steel Stud Selection Tables Introduction Design Considerations Installation Components PAGE B2 B4 B4 B6 B7 System Specifications Single Stud Staggered

More information

DURAGROOVE TM FACADE SYSTEM

DURAGROOVE TM FACADE SYSTEM MARCH 2012 DURAGROOVE TM FACADE SYSTEM AUSTRALIAN OWNED & MANUFACTURED WWW.BGC.COM.AU/FIBRECEMENT MARCH 2012 INTRODUCING INNOVA INNOVA IS A RANGE OF INTERIOR LINING, EXTERIOR FACADE AND FLOORING PRODUCTS

More information

DIRECT-TO-FRAME SYSTEM DIRECT-TO-FRAME SYSTEM TECHNICAL DOCUMENT: SYSTEM INSTALLATION & CONSTRUCTION DETAILS

DIRECT-TO-FRAME SYSTEM DIRECT-TO-FRAME SYSTEM TECHNICAL DOCUMENT: SYSTEM INSTALLATION & CONSTRUCTION DETAILS MASTERWALL AUSTRALIA PTY LTD. 18-20 Cyber Loop, Dandenong South, Victoria, Australia EMAIL. sales@masterwall.com.au WEB. www.masterwall.com.au NATIONAL ENQUIRIES. (03) 9799 6565 FAX. (03) 8740 2180 DIRECT-TO-FRAME

More information

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES CONTENTS 10.1 PLASTERWORK 10.2 2 ND AND 3 RD FIX FINISHES FUNCTIONAL REQUIREMENT 10.1 Plasterwork Workmanship Design Technical Manual TS-011-09-010412 i. All workmanship must be within defined tolerances

More information

Technical Specification Aug 2012

Technical Specification Aug 2012 Technical Specification Aug 2012 Product Description BGC Compressed Fibre Cement sheeting is a high density fibre cement sheet which is ideally suited as a structural substrate for interior floors in dry

More information

maintenance-free free from painting easy to install Fixing Guide Cedral Click

maintenance-free free from painting easy to install Fixing Guide Cedral Click maintenance-free free from painting easy to install Fixing Guide Cedral Click www.cedralsidings.com CONTENT Step by step guide to installing your Cedral Click façade Required materials and tools 1. Prepare

More information

For more information on any of our products and services please visit

For more information on any of our products and services please visit Multiboard Australia is committed to leading the way in setting new standards with cutting edge technology within construction, building and design. Leading the way with an innovative generation of lightweight

More information

EDITION: MAY 2016 DESIGN AND INSTALLATION GUIDE HORIZONTAL INSTALLATION

EDITION: MAY 2016 DESIGN AND INSTALLATION GUIDE HORIZONTAL INSTALLATION EXTERNAL WALL SYSTEM - 50mm, 62mm AND 75mm EDITION: MAY 2016 DESIGN AND INSTALLATION GUIDE HORIZONTAL INSTALLATION CMA-CM40172 HEAD OFFICE Nasahi Building Materials Australia Pty Ltd 1331 Stud Rd, Rowville,

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

Fire Crunch. firecrunch.com.au. TECHNICAL MANUAL Installation : Fire Rate FRL Systems. Alternative Australian Certified Building Solutions

Fire Crunch. firecrunch.com.au. TECHNICAL MANUAL Installation : Fire Rate FRL Systems. Alternative Australian Certified Building Solutions Installation : Fire Rate FRL Systems CONTENTS Fire OVERVIEW... 3 Key Features... 3 Product Applications... 3 Environmental Properties... 3 Fire Protection... 3 AUSTRALIAN CERTIFICATION... 4 FIRE PROPERTIES...

More information

Specifications. Some details shown in this document have been reproduced from CCANZ document CP 01.

Specifications. Some details shown in this document have been reproduced from CCANZ document CP 01. BRICKVENEERS Specifications Bowers Brick Veneer meets the requirements of AS/NZS 4455 as a masonry brick veneer and complies with and exceeds the 15 year durability requirements as stated in the New Zealand

More information

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6 DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00

More information

Wet Areas Using Plasterboard

Wet Areas Using Plasterboard INSTALLATION 168 DEFINITIONS 168 WET AREA REQUIREMENTS 168 WATERPROOFING REQUIREMENTS BY AREA 169 GENERAL REQUIREMENTS 171 FRAMING 171 PLASTERBOARD LAYOUT 171 PLASTERBOARD FIXING 171 CONSTRUCTION DETAILS

More information

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS 1 FOCUS ON GETTING IT RIGHT As with any building project the quality of finish is determined by the foundation upon which it is installed. The most important

More information

FASTER. BETTER. STRONGER. Australia s trusted lightweight building product

FASTER. BETTER. STRONGER. Australia s trusted lightweight building product FASTER. BETTER. STRONGER. Australia s trusted lightweight building product BUILDING WITH PRONTO PANEL Pronto Panel is a non-load bearing panel system that can be used both internally and externally. Pronto

More information

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS Insulation A4/8 K12 AW2194 Issue 10 Sep 2017 INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core Can

More information

DIRECT-TO-FRAME SYSTEM DIRECT-TO-FRAME SYSTEM TECHNICAL DOCUMENT: SYSTEM INSTALLATION & CONSTRUCTION DETAILS

DIRECT-TO-FRAME SYSTEM DIRECT-TO-FRAME SYSTEM TECHNICAL DOCUMENT: SYSTEM INSTALLATION & CONSTRUCTION DETAILS MASTERWALL AUSTRALIA PTY LTD. 18-20 Cyber Loop, Dandenong South, Victoria, Australia EMAIL. sales@masterwall.com.au WEB. www.masterwall.com.au NATIONAL ENQUIRIES. (03) 9799 6565 FAX. (03) 8740 2180 DIRECT-TO-FRAME

More information

K12 Framing Board. Insulation

K12 Framing Board. Insulation Insulation A4/8 K12 AW2161 Issue 7 Dec 2016 INSULATION FOR USE BEHIND wall lining AND FRAMED WALLS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core Can

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

Resysta Wall Cladding Installation Guidelines

Resysta Wall Cladding Installation Guidelines Resysta Wall Cladding Installation Guidelines NOTE: Proper planning of the wall cladding layout is essential for ease of installation of wall cladding boards and wall cladding components. Thoroughly read

More information

ThermaSheet. multi-purpose insulated tile backer panels

ThermaSheet. multi-purpose insulated tile backer panels ThermaSheet multi-purpose insulated tile backer panels A CODE PRODUCT DIMENSIONS RTTBB-06-1200 ThermaSheet Tile Backer Board 6mm 1200mm x 600mm RTTBB-10-1200 ThermaSheet Tile Backer Board 10mm 1200mm x

More information

Multiboard Australia is committed to leading the way in setting new standards with cutting edge technology within construction, building and design.

Multiboard Australia is committed to leading the way in setting new standards with cutting edge technology within construction, building and design. Multiboard Australia is committed to leading the way in setting new standards with cutting edge technology within construction, building and design. Leading the way with an innovative generation of lightweight

More information

rondo accessories CONTENTS:

rondo accessories CONTENTS: rondo accessories SUMMARY Rondo has a range of accessories to complement our steel wall and ceiling systems, which includes Top Hats, Reveal Beads and Angles, as well as a rod bending tool for suspended

More information

DURAGROOVE TM FACADE SYSTEM

DURAGROOVE TM FACADE SYSTEM Technical brochure June 2017 DURAGROOVE TM FACADE SYSTEM www.bgcinnovadesign.com.au BGC s stunning Innova range of facade, lining and flooring products will move you to reassess your concept of excellence

More information

TECHNICAL MANUAL. INSTALLATION : Fire Tested FRL Systems. MgSO4 Sulphate Board NO METAL CORROSIVE CHLORIDE

TECHNICAL MANUAL. INSTALLATION : Fire Tested FRL Systems. MgSO4 Sulphate Board NO METAL CORROSIVE CHLORIDE FIRECRUNCH INSTALLATION MANUAL: FIRE TRESTED FRL SYSTEMS (09_2018) TECHNICAL MANUAL INSTALLATION : Fire Tested FRL Systems FireCrunch Fire MANUAL SEPT 2018 NATA FIRECRUNCH IS AN AUSTRALIAN FIRE TEST BUILDING

More information

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights 1 Exam Prep Application and Finishing of Gypsum Board GA-216-2013 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2013 Application and Finishing of Gypsum Panel Products. Each

More information

0331 Brick and block construction

0331 Brick and block construction 0331 BRICK AND BLOCK CONSTRUCTION 1 GENERAL 1.1 STANDARDS Materials and construction: To AS 4773.1 and AS 4773.2. 2 PRODUCTS 2.1 DURABILITY Exposure environment: [complete/delete] Exposure locations: To

More information

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS Insulation A4/6 K15 AW2161 Issue 3 Dec 2016 INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core Suitable

More information

Note:

Note: Email: sales@koolwall.com.au JANUARY 2009 ISSUE Note: When installing the koolwall panel system, please ensure you are using a copy of the most recently published edition of the installation manual. If

More information

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights 1 Exam Prep Application and Finishing of Gypsum Board GA-216-2016 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2016 Application and Finishing of Gypsum Panel Products. Each

More information

Installation Guide. HardiePanel Compressed Sheet INTERIOR

Installation Guide. HardiePanel Compressed Sheet INTERIOR Installation Guide HardiePanel Compressed Sheet INTERIOR Australia August 2018 Make sure your information is up to date. When specifying or installing James Hardie products, ensure that you have the current

More information

Section 10. Rendering, Plasterboard & Fibre Cement Sheeting

Section 10. Rendering, Plasterboard & Fibre Cement Sheeting MARKETING PROPERTY-PROJECT SERVICES STD - D905 VOLUME 2 Service Station Construction SPECIFICATION Section 10 Rendering, Plasterboard & Fibre Cement Sheeting Index 10.1 Extent of Work 10.2 Rev 07.8 General

More information

EDITION: MAY 2016 DESIGN AND INSTALLATION GUIDE HORIZONTAL INSTALLATION

EDITION: MAY 2016 DESIGN AND INSTALLATION GUIDE HORIZONTAL INSTALLATION EXTERNAL WALL SYSTEM - 50mm, 62mm AND 75mm EDITION: MAY 2016 DESIGN AND INSTALLATION GUIDE HORIZONTAL INSTALLATION CMA-CM40172 HEAD OFFICE Nasahi Building Materials Australia Pty Ltd 1331 Stud Rd, Rowville,

More information

Cement Particle Board

Cement Particle Board Cement Particle Board MULTI-PURPOSE PARTICLE BOARD FOR FLOORS AND CEILINGS Datasheet 58 Product Code: 18mm & 22mm: 1245 18mm & 22mm thick high mass, t&g cement particle board for floors and ceilings JCW

More information

Insulbreak. Insulation. thermal break solution

Insulbreak. Insulation. thermal break solution Insulation A4/8 TB AW1559 Issue 4 Nov 2013 Insulbreak thermal break solution 3-in-1 Insulation, thermal break and vapour barrier Delivers a R0.20 thermal break solution for steel-framed construction Helps

More information

DURASCAPE TM BASE SHEETS

DURASCAPE TM BASE SHEETS MAY 2015 BASE SHEETS AUSTRALIAN OWNED & MANUFACTURED WWW.BGCINNOVADESIGN.COM.AU MAY 2015 INTRODUCING INNOVA BGC S STUNNING RANGE OF FACADE, LINING AND FLOORING PRODUCTS, INNOVA WILL MOVE YOU TO REASSESS

More information

K17 Insulated Plasterboard

K17 Insulated Plasterboard Insulation A4/6 K17 AW2032 Issue 10 Nov 2015 K17 Insulated Plasterboard INSULATED DRY-LINING PLASTERBOARD FOR PLASTER DAuB / ADHESIVE BONDING Super high performance rigid thermoset phenolic insulation

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE insulation Eco-Versal A universal solution for insulating pitched roofs, floors, walls, dormer cheeks & ceilings Eco-Versal 5 in 1 Eco-Versal 5 in 1 Polyisocyanurate (PIR) foam core with aluminium foil

More information

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Thank you for purchasing the Genesis Dura-Max Brick Panel system for your project. The system allows you to have the look

More information

Technical Manual. Harpro High-Rise External Wall System HBG-003, September 2015 Homebuild Global Pty Ltd

Technical Manual. Harpro High-Rise External Wall System HBG-003, September 2015 Homebuild Global Pty Ltd Technical Manual Harpro High-Rise External Wall System HBG-003, September 2015 Homebuild Global Pty Ltd Our Story Our Story Homebuild Global Pty Ltd is a young and dynamic Australian company based in Sydney

More information

Pro-panel Cement Board Technical Guide

Pro-panel Cement Board Technical Guide Pro-panel Cement Board Technical Guide Pro-panel Cement Board Technical Guide for Cold Formed Steel Construction Complies with; ASTM C1186 BS 476 ASTM G-21 www.framecad.com Building Products and Supply

More information

Installation Guide. ExoTec TM RAW (Pre-Finished) Facade Panel And Fixing System COMMERCIAL & RESIDENTIAL

Installation Guide. ExoTec TM RAW (Pre-Finished) Facade Panel And Fixing System COMMERCIAL & RESIDENTIAL Installation Guide ExoTec TM RAW (Pre-Finished) Facade Panel And Fixing System COMMERCIAL & RESIDENTIAL Certificate CM40221 Australia October 2018 Make sure your information is up to date. When specifying

More information

Technical Manual. Harpro Low-Rise Multi-Residential & Houses External Wall System HBG-001, March 2015 Homebuild Global Pty Ltd

Technical Manual. Harpro Low-Rise Multi-Residential & Houses External Wall System HBG-001, March 2015 Homebuild Global Pty Ltd Technical Manual Harpro Low-Rise Multi-Residential & Houses External Wall System HBG-001, March 2015 Homebuild Global Pty Ltd Our Story Our Story We are a young and dynamic Australian company based in

More information

Architectural Roofing

Architectural Roofing ArcTray 1. GENERAL This section deals with the supply and fixing of ArcTray overlap rigid sheet metal profiled roofing and/or cladding complete with accessories. Documents 1.1 DOCUMENTS REFERRED TO Documents

More information

LP SmartSide Perfection Shingle

LP SmartSide Perfection Shingle Application Instructions Fiber Substrate Lap Siding A A - Lap Siding ON SITE STORAGE Store off the ground well supported, on a flat well-drained surface. (Diagram 1a) Additional support may be required

More information

exbound is available in the following lengths: exbound is dimensionally stable, allowing it to be an excellent external cladding panel.

exbound is available in the following lengths: exbound is dimensionally stable, allowing it to be an excellent external cladding panel. is a versatile, glass fibre reinforced, (50%) recycled wood fibre and magnesium based cladding. The panels have been specifically fabricated for external use with the latest fire retardant chemicals to

More information

DURACOM TM FACADE SYSTEMS

DURACOM TM FACADE SYSTEMS JULY 2015 FACADE SYSTEMS AUSTRALIAN OWNED & MANUFACTURED WWW.BGCINNOVADESIGN.COM.AU JULY 2015 INTRODUCING INNOVA BGC S STUNNING RANGE OF FACADE, LINING AND FLOORING PRODUCTS, INNOVA WILL MOVE YOU TO REASSESS

More information

Structural flooring product for internal and external residential flooring applications. Reinforced with mesh on underside.

Structural flooring product for internal and external residential flooring applications. Reinforced with mesh on underside. Made in Australia Installation guide IMPORTANT NOTES 1. Scyon Secura Exterior flooring is suitable for tiled internal and external residential flooring applications only. The maximum loading capacities

More information

INSTALLATION GUIDE COMPOSITE DECKING

INSTALLATION GUIDE COMPOSITE DECKING INSTALLATION GUIDE COMPOSITE DECKING sales@ecoscapeuk.co.uk CONTENTS STORAGE & HANDLING 03 SAFETY & USE 04 TOOLS 05 CALCULATING BOARDS 06 DECKING COMPONENTS + ACCESSORIES 07 PRE INSTALLATION NOTES 09 FALLS

More information

WB12 180x20. (160mm cover) Vertical. Fineline WB12F 180x20. (160mm cover) Vertical. Bevelback AW62 180x20 (148mm cover) Horizontal

WB12 180x20. (160mm cover) Vertical. Fineline WB12F 180x20. (160mm cover) Vertical. Bevelback AW62 180x20 (148mm cover) Horizontal Overview Vulcan Cladding is created from thermally modified New Zealand plantation timber and engineered with a patented vertical grain construction for superior weathering characteristics. A fine sawn

More information

TECHNICAL MANUAL. Wall System Descriptions and Building Details. May 13, 2013 V1.3

TECHNICAL MANUAL. Wall System Descriptions and Building Details. May 13, 2013 V1.3 TECHNICAL MANUAL Wall System Descriptions and Building Details May 13, 2013 V1.3 Head Office: 03-310 7981 E-Mail: mark@cladx.co.nz Web Site: www.cladx.co.nz Contact: 027 600 1234 TABLE OF CONTENTS 2 1

More information

STRATUM TM ERA CLADDING SYSTEM

STRATUM TM ERA CLADDING SYSTEM FEBRUARY 2015 CLADDING SYSTEM AUSTRALIAN OWNED & MANUFACTURED WWW.BGCINNOVADESIGN.COM.AU FEBRUARY 2015 INTRODUCING INNOVA BGC S STUNNING RANGE OF FACADE, LINING AND FLOORING PRODUCTS, INNOVA WILL MOVE

More information

SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS

SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS PART 1 GENERAL 1.1 RELATED WORK SPECIFIED IN OTHER SECTIONS 1.2 DESCRIPTION OF SYSTEM A. GENERAL:

More information

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED ConquererTM Panel Products Introduction ConquerorTM International Ltd is New Zealand s only manufacturer

More information