FIBER OPTIC PROJECT IMPLEMENTATION
|
|
- May Baker
- 6 years ago
- Views:
Transcription
1 FIBER OPTIC PROJECT IMPLEMENTATION Fiber Project Management [Draw your reader in with an engaging abstract. It is typically a short summary of the document. When you re ready to add your content, just click here and start typing.] ADEJOLA JOHNSON Msc. CEO Imt computers Nig. Ltd FOA Representative in Nigeria #718
2 PROJECT IMPLEMENTATION INTRODUCTION TRENCHING Trench making is one of the fiber project implementation process. It involves removal of the topsoil or whichever terrain that is found at the location to a given depth. There are three basic trenches that is adoptable in most OFC Projects Trench Type S1 or R1 Filling the trench with the extracted material from the soil. This trench type can be regarded as deep trench of 1.2m deep,as approved by the client. This type of trench is achievable mostly in the backborne
3
4 Trench Type S2 or R2 Introduction of 20cm concrete layer directly above the duct which will act as a shield protection
5 Trench Type S3 or R3 Complete concrete encasement of the entire trench. Some of the terrain to come across during trenching include, but not limited to ASPHALT CUTTING, CONCRETE BREAKING, THRUST BORING, PAVE STONES, SWAMP AREAS, BRIGDE CROSSING
6 Where there is road crossing, the road must be backfilled and reinstated with asphalt or any materials used for the constructed of the road before cutting. This shall be done immediately after the installation of the ducts. Not more than 100metres trench shall be left open overnight. Warning signs, fencing, guards and watchmen are required where necessary. The trench shall be dug in such a way that the minimum cover over the uppermost layer of ducts is 100cm in carriageway and 45cm in footpaths. The bottom of the trench shall be level and free from stones and debris, or other objects which may damage the ducts. MANHOLE WORK Manhole, Handhole, JB or any other name it is called, is simply a concrete box found on fiber project route mainly for accessibility, maintenance and securing the enclosure. As to allow easily splice box installation and cable coils with respect of maximum bending radii, the dimensions of the manhole will not be less than:
7 W x H x L=1m x1.15m x 1.4m (urban manhole) W x H x L =0.7m x 0.7m x 0.9m (suburban or rural manhole) Lateral walls and covers will be resistant to a minimum of: 400 KN for manholes under roadways 250 KN for manholes buried in verges or sideways The manhole cover is made of iron, but lately rubber lid are becoming prominent. Whichever is used, the lid must have handle to lift it up and lock for additional protection. In order to ensure uniformity, the vendor must ensure that same manhole cover is used across the network. This must be approved by the client MAN HOLE COVER LID 400KN Height = 1.15m Length = 1.4m Width = DUCT WAYS
8 TYPES OF MANHOLE IN-SITU These are man hole casted on-site, the form work and all other concrete material are brought to the site for casting. This is not allowed except the man hole location is a difficult terrain for Hiab movement and manhole installation. Such terrain include swampy areas, no access area (residential compound) PRE-CAST These are the manhole that are casted in the construction yard meant for the project (located very close to the project route. Aftyer the casting. it is expected to be cured by wetting them regularly or subject them in to the curing oven for days. After the curing process, the hiab will be engaged to take each manhole to their respective and waiting manhole trenches. The lifting and the dropping of the manhole need to be guided to align well. MAN HOLE CASTING MAN HOLE CURING OVEN MAN HOLE INSTALLATION
9 MANHOLE DISTANCES & PLACEMENT Manhole is one of the major civil work of the fiber implementation project. As stated in the SOW, the distances of the manhole is already specified. Metro project (project within the town) most of the time by standard is 250meters interval unless otherwise approved, while backbone or long-haul installation have the manhole spacing as 950meters or 1000meters NOTE: At every macro bend or sharp corner manhole must be inserted irrespective of the distance of the last inserted manhole. MH 1 MH 2 IN MH 5 OUT MH 6 MH 7 MH 4 OUT MH 3 IN
10 Where bridges, streams or other obstacles require crossing, chambers should be placed on either side of the obstruction. Manholes should not be installed on steep banks or slopes. The manhole construction must ensure the covers are well above the footpath/ground level and also allow the cover to be raised or lowered to accommodate changes in the footpath/ground level using conventional manhole MANHOLE TRACKING Manhole numbering or labelling is very essential and crucial to preparation of the AS-BUILT DRAWING.it is marked serially as MH 1, OR HH1, JB 1. This label can be written on the MANHOLE itself or in a situation where no space to write it, it can be outwardly inscribed on the wall or road divider or pole nearer to it or better still perform what is referred to as internal TAGGING. Internal TAGGING is mostly done inside Manhole that contains SPLICE ENCLOSURE
11 ROUTE MARKER What is route marker? This is one of the project deliverables that indicates that a telecom cable or underground telecom facility already passed through the route. This is very essential for maintenance and more so for the new telecom company to be guided while trying to trench same route. NOTE: As rule of Thumb every underground facility sighted (be it water pipe, telecom cable, electric cable etc.) must be given minimum of 1meter either side before any other facility be installed. The route marker must be placed at regular interval as stated by the client. NOTE: in metro project of 250m Manhole intervals the route marker is also placed in between manhole (hence route marker interval on a metro project is 250ms. In a backbone or long-haul project where the manhole interval is 950m 0r 1000m as the case may be, the route marker is also placed at such intervals, except at a micro bend or sharp turning
12 Samples of route markers of Nigeria telecom companies DUCTING & COUPLING Galvanized Steel pipe of internal diameter of 100mm and normal length of 6m shall be installed in areas requiring additional protection for optical fiber cable and where the use of PVC duct is susceptible to damage. Also it shall be installed where instances of road crossing. Steel pipe shall be used when crossing the bridge, open sewer ditches, under railway and when crossing major roads. Duct ends shall be closed during construction with rubber plugs to prevent dust and water from entering Suitable plug shall be provided and inserted into the end of each duct to prevent the ingress of water and/or foreign matter
13 (PVC Polyvinyl chloride) (HDPE: High density polyethene) GI Pipe WHAT IS COUPLING FOR THE CONTINUITY of the duct and sub-ducts there is need for joining (coupling) PVC (Polyvinyl chloride) COUPLING INVOLVE SETTING THE FEMALE SIDE OF THE PIPE AGAINST THE MALE SIDE Female end Male end
14 SUB-DUCT (HDPE) COUPLING THE SUB-DUCT KNOWN AS HDPE (High Density Polyethylene) VARY IN SIZES 33/40mm. It is uniform in size. Unlike PVC, it does not have male and female sides. Joining requires a special coupler and techniques SUB DUCT COUPLER BACKFILLING Backfilling shall consist of sifted soil to a minimum depth of 100cm above the uppermost duct layer. The backfilling shall be compacted so as to leave no voids around or between the ducts. Where sifted soil is not readily available, sand may be used. Normally the excavated materials may be used. All backfilling must shall be backfilled in layers of 150mm to 250mm in the reversed order to which they were excavated and thoroughly compacted.
15 Warning tape is required here before total backfilling. Reinstatement only takes place where major terrain such as asphalt cutting and concrete breaking take place FIBER WORK The optical network is to be constructed using quality optical cable that is suitable for the underground environment. The cable is provided by the Client most of the time. The performance of the cable to use is prescribed by the client (the cable types, cable wavelength and cable attenuation, all these are specified in the SOW Cable installation must comply with international standards Bend radius during installation should not be less than 20x outside diameter of cable while the minimum bend radius after installation should not less than 10x
16 outside diameter of cable. Cable slack shall be provided as 5meter within the Manhole and 10meters at termination points. A minimum of 0.5m is required as slack within the termination enclosure. The major Fiber work after ducting is pulling of the cable into the duct which involve inserting of the fiber optics cable into the sub-duct from manhole to manhole to the end of the cable drum or cassette. Equipment such as the calibration rope, stager, hand and blowing machine can be deployed to achieve this stage STAGGER AIR COMPRESSOR
17 FIBER CABLE TERMINATION After the installation of the cable into the ducts, termination into the optical connection accessories such as patch panel, splice enclosure, pigtails will begin. Expected loss during termination is an issue to take into cognizance. There is standard for this from the industry, but nevertheless the client dictate what she wants here concerning the termination, fiber cords and pigtails, fiber distribution panels, optical fiber splice etc Connectorization and splicing Mechanical and fusion splicing are the major type of splicing that can be deployed anywhere.
18 Fiber optic cable splicing procedure (How to splice fiber optic cable) 1. Strip fiber cable jacket. Strip back about 3 meters of fiber cable jacket to expose the fiber loose tubes or tight buffered fibers. Use cable rip cord to cut through the fiber jacket. Then carefully peel back the jacket and expose the insides. Cut off the excess jacket. Clean off all cable gel with cable gel remover. Separate the fiber loose tubes and buffers by carefully cutting away any yarn or sheath. Leave enough of the strength member to properly secure the cable in the splice enclose. 2. Strip fiber tubes. For a loose tube fiber cable, strip away about 2 meters of fiber tube using a buffer tube stripper and expose the individual fibers. 3. Clean cable gel. Carefully clean all fibers in the loose tube of any filling gel with cable gel remover. 4. Secure cable tubes. Secure the end of the loose tube to the splice tray and lay out cleaned and separated fibers on the table. Strip and clean the other cable tube s fiber that is to be spliced, and secure to the splice tray. 5. Strip first splicing fiber. Hold the first splicing fiber and remove the 250um fiber coating to expose 5cm of 125um bare fiber cladding with fiber coating stripper tool. For tight buffered fibers, remove 5cm of 900um tight buffer first with a buffer stripping tool, and then remove the 5cm of 250um coating. 6. Place the fusion splice protection sleeve. Put a fusion splice protection sleeve onto the fiber being spliced. 7. Clean the bare fiber. Carefully clean the stripped bare fiber with lint-free wipes soaked in isopropyl alcohol. After cleaning, prevent the fiber from touching anything.
19 8. Fiber cleaving. With a high precision fiber cleaver, cleave the fiber to a specified length according to your fusion splicer s manual. 9. Prepare second fiber being spliced. Strip, clean and cleave the other fiber to be spliced. 10. Fusion splicing. Place both fibers in the fusion splicer and do the fusion splice according to its manual. 11. Heat shrink the fusion splice protection sleeve. Slide the fusion splice protection sleeve on the joint and put it into the heat shrink oven, and press the heat button. 12. Place splice into splice tray. Carefully place the finished splice into the splice tray and loop excess fiber around its guides. Ensure that the fiber s minimum bending radius is not compromised. 13. Perform OTDR test. Perform a OTDR test of the splice and redo the splice if necessary. 14. Close the splice tray. After all fibers have been spliced, carefully close the splice tray and place it into the splice enclosure. 15. Bidirectional OTDR test (or power meter test). Test the splices with an OTDR or power meter from both directions. 16. Mount the splice enclosure. Close and mount the splice enclosure if all splices meet the specifications. TESTING Fusion splicers are used to create long cable lengths by splicing multiple cable segments. Although the splicer will give an estimate of the splice loss, the only
20 way to test it is with an OTDR. Since OTDRs have directional errors, testing may be required from both directions and averaged. Generally long concatenated cables are tested with an OTDR and traces kept for documentation in case of restoration. OPTICAL POWER- POWER OR LOSS? ( ABSOLUTE VS. RELATIVE ) Practically every measurement in fiber optics refers to optical power. The power output of a transmitter or the input to recever is absolute optical power measurements, that is, you measure the actual value of the power. Absolute optical power levels are measured in dbm. 0 dbm is equivalent to 1 mw of power, hence the m in dbm
21
BIDDING FOR A FIBER PROJECT
IMTFIBER NIGERIA BIDDING FOR A FIBER PROJECT PROJECT DOCUMENTATION TIPS 1/1/2016 ADEJOLA JOHNSON Msc. CEO Imt computers Nig. Ltd FOA Representative in Nigeria #718 www.imtfiber.com info@imtfiber.com 08039576767
More informationMaterial will comply with those standards as established by UL or NEMA and shall be commercial grade. All materials will be new and free from defects.
APPENDIX A: OSP INSTALLATION SPECIFICATIONS Material Requirements Material will comply with those standards as established by UL or NEMA and shall be commercial grade. All materials will be new and free
More informationCONDUITS AND FITTINGS
CONDUIT AND FITTINGS Rigid Steel Conduit 3801 Rigid PVC Conduit 3803 HDPE Conduit 3803 Flexible Non Metallic Liquid Tight Conduit Type LFNC-B 3804 PVC Coated Urethane Lined Galvanized Rigid Steel Conduit
More informationITEM NO SABS SECTION 1 : PRELIMINARY AND GENERAL 1200 A FIXED-CHARGE ITEMS Contractual Requirements Sum 1.0 -
1 SABS 1200 A SECTION 1 : PRELIMINARY AND GENERAL SECTION 1: PRELIMINARY & GENERAL PAYMENT DESCRIPTION UNIT QUANTITIES RATE AMOUNT 1.1 8.3 FIXEDCHARGE S 1.1.1 8.3.1 Contractual Requirements 8.3.2 Establish
More informationSPECIAL SPECIFICATION 6664 Level (3) Communications System
2004 Specifications CSJ 1200-05-014 SPECIAL SPECIFICATION 6664 Level (3) Communications System 1. Description. A. This Item will govern the installation of all facilities belonging to Level (3) Communications,
More informationSPECIAL SPECIFICATION 6658 Time Warner Communications System
2004 Specifications CSJ 1200-05-014 1. Description. SPECIAL SPECIFICATION 6658 Time Warner Communications System A. This Item will govern the installation of all facilities belonging to Time Warner Cable
More informationMulti-Gard PVC Assembly/ Field Cuts
Multi-Gard PVC Assembly/ Field Cuts Assembly 1. Distribute Multi-gard sections along the sides of the trench with male ends pointing towards starting vault entrance.. Remove protective cap and install
More informationCHAPTER 11 CONDUITS AND FITTINGS
CONDUITS AND FITTINGS CHAPTER 11 CONDUITS AND FITTINGS The standards and requirements for conduits and fittings used for traffic control signal and lighting systems are presented in this chapter. 11.1
More informationCourse name : Outside Plant - Fibre Optics Civil Works Professional Knowledge and Skills for Certification
Course name : Outside Plant - Fibre Optics Civil Works Professional Knowledge and Skills for Certification Course Detail: DURATION: 5 days TARGET GROUP: Any person who needs to do trenching, duct installation,
More informationSECTION UTILITY POLYETHYLENE CONTAINMENT PIPE SYSTEMS
SECTION 02670 UTILITY POLYETHYLENE CONTAINMENT PIPE SYSTEMS PART 1 - GENERAL 1.01 WORK INCLUDED A. Trenching and other excavation. B. Ground water control. C. Pipe bedding. D. Installation of containment
More informationENGINEERING COMMITTEE Interface Practices Subcommittee SCTE Fusion Splicing Equipment and Applications for the Cable/Broadband Industry
ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE 134 2012 Fusion Splicing Equipment and Applications for the Cable/Broadband Industry NOTICE The Society of Cable Telecommunications Engineers
More informationCONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 602 MARCH 1993 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER 602.01 SCOPE 602.02 REFERENCES 602.05 MATERIALS TABLE OF CONTENTS
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 134 2012 Fusion Splicing Equipment and Applications for the Cable/Broadband Industry NOTICE The Society of Cable
More informationTelecommunications Infrastructure
Telecommunications Infrastructure Table of Contents Contents 1. INTRODUCTION... 2 2. DUCTING CAPACITY... 3 3. SUB DUCT SIZING... 4 4. DUCTING AND SUB DUCTING CONSTRUCTION AND COLOUR... 5 5. BUILDING ENTRANCE:...
More informationSECTION UNDERGROUND ELECTRICAL CONSTRUCTION
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 41 UNDERGROUND ELECTRICAL CONSTRUCTION A. This section specifies the furnishing, installation, and connection of precast manholes and pullboxes with ducts
More informationTS 803 DUCTS DUCT INSTALLATION, PROTECTION AND MARKING WITHIN A TRENCH OPEN TRENCH DUCT INSTALLATION PROFILE
TORONTO TRANSPORTATION March 2012 TS 803 DUCTS TABLE OF CONTENTS 1. DRAWINGS TTD 803.001 TTD 803.010 DUCT INSTALLATION, PROTECTION AND MARKING WITHIN A TRENCH OPEN TRENCH DUCT INSTALLATION PROFILE 2. CONSTRUCTION
More informationSection 2: Underground
Section 2: Underground GENERAL INSTALLATION REQUIREMENTS FOR UNDERGROUND FACILITIES Underground electric service and meter location will be established by NHEC upon site visit. In some instances the type,
More informationMulticell. Vikimatic MultiCell Conduit Systems MULTICELL
Multicell Vikimatic MultiCell Conduit Systems These guidelines should help you install MultiCell Conduit in the simplest way possible and should be read in their entirety before attempting to install the
More informationSpecifications and Installation Requirements for Underground Service for Residential Developments
Specifications and Installation Requirements for Underground Service for Residential Developments December 12, 2005 NOVEC Requirements for Underground Residential Developments 1. Scope This specification
More informationSPECIAL SPECIFICATION 6666 Charter Communications System
2004 Specifications CSJ 1200-05-014 SPECIAL SPECIFICATION 6666 Charter Communications System 1. Description. A. This Item will govern the installation of all facilities belonging to Charter Communications,
More informationEI INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV
Network(s): Summary: ENGINEERING INSTRUCTION EI 02-0019 INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV EPN, LPN, SPN This engineering instruction details the minimum requirements acceptable for the installation
More informationCONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 603 NOVEMBER 2017 (Formerly OPSS 603, November 2015) Note: The PROV published in November 2017 replaces OPSS 603 COMMON, November 2015 with no technical
More informationDemarcation Points. Example 1
Example 1 control of distribution equipment including connection assets, ending at the customer. REVISION 03 14/04/10 Example 2 ROAD The transformer is normally at the property line. If the transformer
More informationUNDERGROUND DROP CABLE CONDUIT INSTALLATION AND SPECIFICATION GUIDELINES FOR SINGLE DWELLING RESIDENTIAL APPLICATIONS
UNDERGROUND DROP CABLE CONDUIT INSTALLATION AND SPECIFICATION GUIDELINES FOR SINGLE DWELLING RESIDENTIAL APPLICATIONS 1. SPECIFICATIONS This document details the specifications for the installation of
More informationA. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.
ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 05 28 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationUnderground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11
Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (URD) Index General Discussion... 1-2 Description... 3-7 Drawings (Available
More informationUNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1
GENERAL: The scope of this document is to provide instruction for the installation and testing of chilled water piping installed for the University of Missouri. DESIGN GUIDELINES: 1. Materials 1.1. Pipe
More informationSTANDARD SPECIFICATIONS JULY 2012 S-11 CULVERTS, HEADWALLS AND ROADSIDE DRAINAGE TABLE OF CONTENTS
TABLE OF CONTENTS 11.01 SCOPE OF WORK... 1 11.02 REFERENCES... 1 11.03 MATERIALS... 2 11.04 GRANULAR & NATIVE BACKFILL... 2 11.05 CONSTRUCTION... 2 11.06 MEASUREMENT FOR PAYMENT... 5 11.07 BASIS OF PAYMENT...
More informationSECTION STORM DRAINAGE
SECTION 02720 STORM DRAINAGE PART 1 - GENERAL 1.01 WORK INCLUDED A. Trenching and other excavation. B. Ground water control. C. Pipe bedding. D. Installation of storm drains and appurtenances. E. Installation
More informationSECTION ELECTRICAL SITE UTILITIES
SECTION 16402 ELECTRICAL SITE UTILITIES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Electrical site utilities and coordination of requirements with the utility company and service specifications.
More informationCONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 604 NOVEMBER 2004 CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used
More informationWESTERN UNDERGROUND COMMITTEE GUIDE 3.4 (3.4/00/0565)
WESTERN UNDERGROUND COMMITTEE GUIDE 3.4 (3.4/00/0565) PLASTIC CONDUIT AND FITTINGS PLACING INSTRUCTION NOTE: This "Guide" summarizes the opinions, recommendations, and practices of the Western Underground
More informationHEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics
HEKAPLAST PE-HD twin wall cable ducts and cable protection pipes for underground installation HEGLER HEKAPLAST III/ HEKAPLAST: Twin wall cable ducts or cable protection pipes to DIN 696, manufactured from
More informationH. Underground Transmission System Design
H. Underground Transmission System Design In addition to analyzing potential routes, the Company considered several different design technologies for the proposed underground transmission supply lines,
More informationA. Section Includes: Electrical site utilities and coordination of requirements with the utility company and service specifications.
16402 ELECTRICAL SITE UTILITIES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 33 50 00. *************************************************************************************************************
More informationSUPPLEMENTARY SECTION: STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018
STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018 PART 1 - GENERAL... 2 1.1 Work Included... 2 1.2 Related Sections... 2 1.3 Reference Standards... 2 1.4 Shop Drawings... 3 1.5 Certificates...
More information3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).
SECTION 16111 CONDUITS PART 1 - GENERAL 1.01 DESCRIPTION A. General: Provide conduits, complete, as shown, specified or required per Contract Documents. Principal items include: 1. Rigid aluminum conduit.
More informationSUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION POLYETHYLENE PRESSURE PIPE
SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION 33 11 13.24 POLYETHYLENE PRESSURE PIPE PART 1 GENERAL... 2 1.1 Description... 2 1.2 Reference Specification... 2 1.3
More information1993 SPECIFICATIONS CSJ SPECIAL SPECIFICATION ITEM 4110 CONCRETE ENCASED DUCT BANK
1993 SPECIFICATIONS CSJ 581-1-95 SPECIAL SPECIFICATION ITEM 4110 CONCRETE ENCASED DUCT BANK 1. DESCRIPTION. This Item shall govern for the furnishing and installation of all materials and equipment for
More informationIf a new residence s electrical service is not located within 200 feet of existing
Primary Line Extensions CHAPTER 4 If a new residence s electrical service is not located within 200 feet of existing primary electrical facilities, a primary line extension is required to place a close
More informationSPECIAL SPECIFICATION 1663 Fiber Optic Cable
1993 Specifications CSJ 0192-01-080 SPECIAL SPECIFICATION 1663 Fiber Optic Cable 1. Description. This Item shall govern for the furnishing and installation of fiber optic cable in designated locations
More informationSTATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE N.J. Specification No. Effective Date: July 1,
More informationCONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 623 JANUARY 1990 CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT 623.01 SCOPE 623.02 REFERENCES 623.05 MATERIALS TABLE OF CONTENTS 623.05.01
More informationCONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 604 NOVEMBER 2017 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used
More informationCONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 603 APRIL 2010 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS TABLE OF CONTENTS 603.01 SCOPE 603.02 REFERENCES 603.03 DEFINITIONS 603.04 DESIGN
More informationSpecial Provision No. 421F01 April 2006
RIGID PIPE CULVERTS Item No. FLEXIBLE PIPE CULVERTS Item No. CSP ARCH CULVERTS Item No. STRUCTURAL PLATE CSP Item No. CORRUGATED STEEL PIPE EXTENSIONS Item No. ROCK EXCAVATION FOR CULVERTS Item No. CLAY
More informationSITE SERVICES GUELPH TRANSIT OPERATIONS & MAINTENANCE SECTION WATSON ROAD FACILITY PAGE 1 OF 6 WATER RECLAMATION PROJECT JUNE 2013
WATSON ROAD FACILITY PAGE 1 OF 6 PART 1 GENERAL 1.1 Description The work covered by this Section includes all labour, materials, equipment, and supervision necessary to complete the site services as shown
More informationREVISION OF SECTION 623 IRRIGATION SYSTEM GENERAL
623.01 SUMMARY: GENERAL Section Includes: Landscape irrigation system as shown on the drawings for complete coverage to landscape areas. Furnish design for layout, pipe sizing, valving and head types and
More informationSECTION WASTEWATER FORCE MAINS
SECTION 02732 WASTEWATER FORCE MAINS PART - GENERAL 1.01 GENERAL: A. This section includes the general requirements for design and installation of force main systems serving wastewater lift stations. B.
More informationSECTION EXCAVATING, BACKFILLING, AND COMPACTION FOR UTILITIES
SECTION 02221 EXCAVATING, BACKFILLING, AND COMPACTION FOR UTILITIES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 02200 - Earthwork. 2. 02660 - Water Systems. 3. 02720 - Storm Drainage System. 4.
More informationTYPICAL INSTALLATION INSTRUCTIONS
TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect
More informationSpecification for Installation of Quadbox Modular Access Chambers JMF102, JMF104, JMF106
Specification for Installation of Quadbox Modular Access Chambers JMF102, JMF104, JMF106 Page 1 of 8 INDEX 1 General information...3 2 Safety...3 3 Installation Procedure...3 3.1 Chamber Depth... 4 3.2
More informationPART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER
PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER COMMUNICATIONS LIGHTING Street Lighting Plan 710 Riser... 287 730 Collar for street light pole... 289 731 Pull box... 291 732 Trench for street light
More informationSpecifications for Electrical Underground Residential Distribution Systems
Specifications for Electrical Underground Residential Distribution Systems Specification DDS-2 Revision 13, February 2010 ONCOR ELECTRIC DELIVERY COMPANY SPECIFICATIONS FOR ELECTRICAL UNDERGROUND RESIDENTIAL
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationDETAILED SCOPE OF WORK IN-STREAM TIDAL GENERATING PLANT TISEC COLLECTOR CIRCUITS DEVELOPMENT
PAGE I TABLE OF CONTENTS SECTION DESCRIPTION PAGE 1 GENERAL 1 1.1 OVERVIEW 1 1.2 PREPARATORY WORK CARRIED OUT BY OTHERS 2 1.3 MATERIALS TO BE SUPPLIED BY THE OWNER 2 1.4 PROJECT SCHEDULE 3 1.5 PROJECT
More informationCONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 603 NOVEMBER 2015 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS TABLE OF CONTENTS 603.01 SCOPE 603.02 REFERENCES 603.03 DEFINITIONS 603.04 DESIGN
More informationCONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 603 NOVEMBER 2017 (Formerly OPSS 603, November 2015) Note: The MUNI implemented in November 2017 replaces OPSS 603 COMMON, November 2015 with no technical
More informationTS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS
TORONTO TRANSPORTATION January 2012 TS 804 CABLES TABLE OF CONTENTS 1. DRAWINGS TTD 804.001 TTD 804.002 TTD 804.003 TTD 804.005 TTD 804.006 TTD 804.007 TTD 804.010 TTD 804.015 TTD 804.020 TTD 804.025 TTD
More informationA. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to provide design guidelines for Utility Direct Buried
More informationContact Clark Public Utilities Construction Services department at (360) to initiate a request for service.
CHAPTER3 Clark Public Utilities Commercial Electric Service Handbook Commercial Underground Services Preparing for the installation The following checklist will assist in preparing a project for the installation
More informationPUBLIC WORKS DEPARTMENT GENERAL NOTES
PUBLIC WORKS DEPARTMENT GENERAL NOTES 1. All construction shall be in strict accordance with the standards of the City of Southlake and governed by the North Central Texas Council of Government's Standard
More informationSECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation
SECTION 33 40 00 STORM DRAINAGE UTILITIES 1. PART 1 GENERAL 1.1 RELATED WORK A. Section 31 23 00: Excavation and Fill B. Section 32 00 01: Site Restoration and Rehabilitation C. Special Conditions for
More informationCONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 604 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used
More informationCity of Logan Sanitary Sewer Design Standards
City of Logan Sanitary Sewer Design Standards 2011 http://www.loganutah.org/public_works/engineering/stdsspecsdesign.cfm Table of Contents PART 1. CITY OF LOGAN SANITARY SEWER SYSTEM DESIGN STANDARDS FOR
More informationNEC 2014 Code Changes
NEC 2014 Code Changes Articles 280.21-300.50 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1000 volts II. Instillation III. Connecting Surge
More informationBest Construction Practices and Splicing for Fiber Networks
Best Construction Practices and Splicing for Fiber Networks Simon Salamanca Sr Systems Engineer, Carrier Networks Engineering Services Corning Optical Communications 07/26/2016 Agenda 1 Cable 101 2 Splicing-
More informationElectric Service Standards
V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are
More informationSPECIAL SPECIFICATION 4425 Thermoplastic Pipe
2004 Specifications CSJ 0264-07-028 SPECIAL SPECIFICATION 4425 Thermoplastic Pipe 1. Description. Furnish and install thermoplastic pipe for constructing thermoplastic pipe culverts or thermoplastic storm
More informationITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS
ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS 701-1 DESCRIPTION 701-1.1 This item shall consist of the construction of pipe culverts, and storm drains, removal of existing storm pipes, connections to existing
More informationGas meter clearances and service installation requirements
FEBRUARY 2018 Gas meter clearances and service installation requirements CALL PSE S CUSTOMER CONSTRUCTION SERVICES AT 1-888-321-7779 OR VISIT PSE.COM/CUSTOMERCONSTRUCTION FOR MORE INFORMATION. Builder/owner/developer
More informationRN Optical Termination Panel (RN OTP)
RN Optical Termination Panel (RN OTP) General The RN Optical Termination Panel(RN OTP) is specifically designed to house optical splitters while also catering for fiber termination in a single enclosure.
More informationWIRING METHODS CHAPTER 38
CHAPTER 38 WIRING METHODS SECTION E3801 GENERAL REQUIREMENTS E3801.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3801.2
More informationSpecification for Installation of Modular Access Chambers MJB104
Specification for Installation of Modular Access Chambers MJB104 Sht 1 of 7 INDEX 1 General information... 3 2 Safety... 3 3 Installation Procedure... 3 3.1 Chamber Depth... 4 3.2 Duct Entries... 4 3.3
More informationSECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 26 GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete // // if not applicable to project. Also delete any other item or paragraph
More informationPlease check with your local inspection authority for any additional requirements before installation.
Specifications for Residential Underground Electric Service Installation This brochure addresses most typical residential underground service installations. Variances for the following specifications must
More informationE. CONSTRUCTION PROCEDURES
E. CONSTRUCTION PROCEDURES The Project facilities would be constructed in accordance with established electric utility practices, best management practices, final engineering plans, CL&P s specifications
More informationCW 3530 MANUAL IRRIGATION SYSTEM TABLE OF CONTENTS
October 1990 CW 3530 MANUAL IRRIGATION SYSTEM TABLE OF CONTENTS 1. GENERAL CONDITIONS...1 3. DESCRIPTION...1 5. MATERIALS...1 5.1 General...1 5.2 Testing and Approval...1 5.3 Irrigation Pipe and Fittings...1
More informationDepartment of Building and Zoning Approaches and Sidewalks for ONE AND TWO FAMILY CONSTRUCTION
Department of Building and Zoning Approaches and Sidewalks for ONE AND TWO FAMILY CONSTRUCTION GENERAL ITEMS SUBGRADE Prior to pouring concrete all subgrades must be wetted and compacted. All formwork
More informationSECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)
SECTION 02623 HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE) PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required and install high density
More informationPART 5 WATER SYSTEMS
PART 5 WATER SYSTEMS Abbreviations and Symbols Plan 501 Abbreviations and symbols for water... 205 Concrete Boxes and Hardware 502 27" Frame and cover... 207 503 38" Frame and cover... 209 505 Concrete
More informationCITY OF LA MARQUE, TEXAS CHAPTER 3 WATER SYSTEM DESIGN CRITERIA
CITY OF LA MARQUE, TEXAS CHAPTER 3 WATER SYSTEM DESIGN CRITERIA CHAPTER 3 WATER SYSTEM DESIGN 3.1 WATER SYSTEM DESIGN GENERAL 3.1.1 Criteria for the design of water service and water distribution lines
More informationTECHNICAL NOTE HDPE Pipe and Utility Crossings
TECHNICAL NOTE HDPE Pipe and Utility Crossings TN 5.09 April 2008 Introduction Underground utilities include storm sewer, electric, sanitary sewer, gas, water, telephone and cable. Utility conflicts are
More informationSection 4 Service Lines
Section 4 Service Lines A. General 1. A service line is that portion of a sanitary sewer line that extends from the outer building wall or foundation wall to its connection with the sewer lateral at the
More informationThe Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
More informationTECHNICAL SPECIFICATIONS OF LAYING OF UNDER GROUND POWER CABLE FOR TRANSMISSION LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF LAYING OF UNDER GROUND POWER CABLE FOR TRANSMISSION LINE GETCO/E/TS LUC058/R1
More informationMethod for Installation of PEHD Manholes - a technical report with 29 self-explanatory Figures -
Method for Installation of PEHD Manholes - a technical report with 29 self-explanatory Figures - 1. HDPE Manhole & Chamber Design PEHD Manhole and Chamber design stipulates various manufacturing configurations
More informationCONSTRUCTION SPECIFICATION FOR GROUNDING
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 609 NOVEMBER 2001 CONSTRUCTION SPECIFICATION FOR GROUNDING TABLE OF CONTENTS 609.01 SCOPE 609.02 REFERENCES 609.03 DEFINITIONS - Not Used 609.04 DESIGN
More informationJuly Bill No.1: Preliminaries
Bill No.1: Preliminaries 1 Mobilization 1.1 This item should include site office for the use of the Engineer's and Employer's staffs with the necessary facilities, furniture, computers, printers, photocopier,
More informationA. Bellcore CAO-8546 Specification for Type B, C, and D Plastic Conduit. B. NEMA TC 6& PVC Plastic Utilities Duct for Underground Installation.
PART 1 GENERAL 1.01 SECTION INCLUDES This specification covers Carlon Multi-Gard multiple cell conduit system for installation of voice, data, video, and other low voltage cabling. This system may be installed
More informationSpecial Provision No. 421S01 November 2006
RIGID PIPE CULVERTS (75 Year DSL) Item No. RIGID PIPE CULVERTS (50 Year DSL) Item No. RIGID PIPE CULVERTS (25 Year DSL) Item No. FLEXIBLE PIPE CULVERTS (75 Year DSL) Item No. FLEXIBLE PIPE CULVERTS (50
More informationBill No.1: Preliminaries
Bill No.1: Preliminaries Item No. Description of Works Qty. 1 Mobilization 1.1 This item should include site office for the use of the Engineer's and Employer's staffs with the necessary facilities, furniture,
More informationCITY OF GARDEN PLAIN, KANSAS STANDARDS AND SPECIFICATIONS FOR GAS YARD LINES & METER SETS
All gas yard lines shall be installed, repaired or replaced in accordance with the standards and specifications herein and in accordance with the rules and regulations as set forth in the city s OQ, and
More informationFLORIDA ARMY NATIONAL GUARD, CBJTC CACTF FIBER OPTIC CABLE INSTALLATION, PN SCOPE OF WORK, 28 MARCH 2012
1. General. 1.1 The project will require the provisioning and installation of conduits, hand holes, pull boxes and fiber optic cable extending several miles from a point of beginning to the Combined Arms
More informationUNM IT/Telecommunications Guide Specification Communications Underground Ducts, Raceways and Structures /27/06
Communications Underground Ducts, Structures and Raceways PART 1: GENERAL The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification
More informationSANITARY WASTE AND VENT PIPING
SECTION 15420 - SANITARY WASTE AND VENT PIPING PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSECTION ELECTRICAL CABLE. 1. Trench excavation, backfill, and compaction; Section
02735-1 of 5 SECTION 02735 ELECTRICAL CABLE 02735.01 GENERAL A. Description Electrical cable installation shall include, but not necessarily be limited to, furnishing and placing electrical cable as shown
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Update sections Materials and Special Requirements 3 F. 2. 4 H. 2.; 10. & 11(added) 6/15/16 Updated division
More informationSUPPLEMENTAL DRAWINGS
CITY OF GREATER SUDBURY SUPPLEMENTAL DRAWINGS TO THE ONTARIO PROVINCIAL STANDARD DRAWINGS Rev: February 2012 CITY OF GREATER SUDBURY STANDARD DRAWINGS TABLE OF CONTENTS Greater Sudbury Standard Drawings
More informationITEM NO. 824 SERVICE SUPPLY LINES (WATER)
ITEM NO. 824 SERVICE SUPPLY LINES (WATER) 824.1 DESCRIPTION: This item shall consist of water service supply lines installation and adjustment installed in accordance with these specifications and as directed
More information