STOREFRONT, CURTAINWALL & ENTRANCES

Size: px
Start display at page:

Download "STOREFRONT, CURTAINWALL & ENTRANCES"

Transcription

1 2007 STOREFRONT, CURTAINWALL & ENTRANCES

2 Series Flush Glaze Guide Specifications General Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum framing as shown on the drawings and specified herein. Fixed window framing shall be Series Flush Glaze (2" x 4 1/2") as manufactured by Tubelite Inc., Walker, Michigan. Whenever substitute products are to be considered, supporting technical literature, samples drawings and performance data must be submitted ten (10) days prior to bid in order to make a valid comparison of the products involved. Test reports certified by an independent laboratory must be made available upon request. Performance Requirements Air infiltration shall not exceed.06 CFM/Ft 2 when tested in accordance with ASTM E-283 at a test pressure of 6.24 PSF. There shall be no uncontrolled water entry when tested in accordance with ASTM E-331 "Water Penetration of Exterior Windows, Curtainwalls and Doors by Uniform Static Air Pressure Difference" at a test pressure of 15 PSF. There shall be no uncontrolled water entry when tested in accordance with AAMA at a dynamic pressure equivalent of 15 PSF. Structural performance per ASTM E330 shall be based on a maximum allowable deflection of L/175 of the span or 3/4" maximum. The system shall perform to those criteria under a wind load of (architect specify) PSF. There shall be no buckling, stress on glass, edge seal failure, excess stress on curtainwall structure, anchors and fasteners or reduction in performance when tested in accordance with AAMA at a temperature range of 0 0 to F. There shall be no "Life/Safety" type failures (glass breakage, anchor failures, or structural damage) when tested in accordance with AAMA 501.4, seismic test (lateral cycling.) Thermal transmittance due to conduction (U c ) shall not be greater than.60 - poured & debridged only (or.63 - slotted only) BTU/Hr/Ft 2 /F degree when tested in accordance with AAMA Condensation Resistance Factor (CRF) shall not be less than 56 - poured & debridged only (or 53 - slotted only) when tested in accordance with AAMA The system shall have a Sound Transmission Class (STC) rating of 32 and an Outdoor-Indoor Transmission Class (OITC) rating of 26 when tested in accordance with ASTM E90-97, ASTM E (reapproved 1994) and ASTM E Products Materials Extrusions shall be of aluminum alloy 6063-T5 extruded within commercial tolerance and free from defects impairing strength and/or durability. Main framing sections to be of.075 inch minimum wall thickness and glazing stop moldings of.060 inch thickness. Screws, bolts and all other accessories to be compatible with the aluminum under normal service conditions. Glazing shall be by means of an exterior and interior roll-in wedge of high quality extruded elastomeric material. Optional: Thermal barrier shall be a two part chemically curing, unfilled polyurethane casting resin poured in place for perimeter members. Intermediate vertical members shall be slotted for efficient thermal performance. Finish All exposed framing surfaces shall be free of scratches and other serious blemishes. Finish to be: (architect select) Etched and clear anodized (AAM12C22A31) Clear - Class 2 (OA) (AAM12C22A41) Clear - Class 1 (2A) Electrolytically deposited color (AAM12C22A44) Class 1 Champagne (4K) Light Amber (2K) Amber (1K) Statuary Bronze(3K) Black (OD) Fluoropolymer painted color. Execution Installation Shall be in accordance with the manufacturer s installation instructions and the approved shop drawings. Note: In keeping with Tubelite s policy of continuing product improvements, all specifications are subject to change without written notice by the manufacturer. 2007

3

4

5

6 Series Flush Glaze Isometric Assembly Details D BUTTS E OFFSET PIVOTS F CENTER HUNG CONCEALED CLOSER G BUTTS H OFFSET PIVOTS A P-1133 x T- w,,,, j A - T WATER DIVERTER <EA. SIDE) E P-1134 m MODIFIED (EA. SIDE1 x NOTE! USE DRILL FIXTURE P-1139 TUBELITE smemc+mberuman(is 1998

7 Series Flush Glaze Isometric Assembly Details A NOTE! \ \ USE DRILL E E I E //I NOTE E B E E E-14142, WATER I I DIVERTER I I (EA SIDE, I I i E NOTE! USE DRILL FIXTURE P-1139

8 Series Flush Glaze Isometric Assembly Details NOTE! r USE DRILL FIXTURE P-1139 T T T NOTE! T E T USE DRILL FIXTURE P-1139 / I / /f E T (4) S T / T-14142, m WATER DIVERTER (EA. SIDE) L-141U4 /-=a. L T T T NOTE! USE DRILL FIXTURE P-1139

9 Series Flush Glaze Isometric Assembly Details E m (3) s-2 P-Y141 CLIP 7 / / I I t E / m (3) s-202 L E-4531 P-503 FILLER E , L P-503 FILLER / t E-4531 E P E-1451 / E-4531 P-503 FILLER tf P-973 CLIP (INCLUDES SCREWS) 531 D m NOTE! ---- USE DRILL FIXTURE P-1139 < E-1438 F HARDWARE PART NUMBER DOOR REINF. FRAME REINF. PART NUMBER PART NUMBER SLOTTED BUTT P P MORTISED BUTT P-092 I INTERMEDIATE p-75l LH,-,R RH OFFSET PIVOT! P-1219 P-360 I I P-1218 P-683 I

10 Series Flush Glaze Isometric Assembly Details x NOTE! E ,,- E USE DRILL FIXTURE P-1139 p-1218 CLIP MODIFIED P-092 : // / 0 P-695R G P-675 J,. S-056 r- E-1438 HARDWARE PART NUMBER DOOR REINF. FRAME REINF -050 PART NUMBER PART NUMBER SLOTTED BUTT P P-538 MORTISED BUTT P-092 P-1219 INTERMEDIATE p-75i OFFSET PIVOT LH OR RH P-360 TUBELITE ST-b

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59 14.53 T14000 Series Flush Glaze Structural Values Shape Description Area Ixx Sxx Iyy Syy T1400 Vertical Mullion T1430 Heavy Duty Vertical Mullion T1435 Open Back Heavy Duty Vertical T14022 Snap-In Filler With Deep Pocket T /2" x 4 1/2" Open Back Horiz * * * * * T " x 4 1/2" Self Mating Horiz * * * * * T14106 Expansion Mullion (Female Half) T14107 Expansion Mullion (Male Half) T14108 Corner Mullion - Single Pocket T14109 Corner Mullion - Single Pocket T14110 Corner Mullion - Double Pocket T14141 Open Back Vertical T14142 Snap-In Filler - Shallow Pocket T14143 Horizontal Mullion * * * * * T14240 Open Back Horizontal * * * * * T14241 Open Back Vertical With Pocket * * * * * T14242 Snap-In Filler With Pocket * * * * * T /8" x 4 1/2" Open Back Vert * * * * * T45005 Open Back 135 Degree Corner Mull * Consult Factory For Section Properties

60 14.54 E14000 Series Flush Glaze Structural Values Shape Description Area Ixx Sxx Iyy Syy E1400 Vertical Mullion E1403 Horizontal Mullion E1430 Heavy Duty Vertical Mullion E1435 Open Back Heavy Duty Vertical E1438 Open Back Door Jamb - No Pocket E1451 2" x 4 1/2" Slick Tube E14021 Door Jamb With Two Pockets E14022 Snap-In Filler With Deep Pocket E /2" x 4 1/2" Open Back Horiz E " x 4 1/2" Self Mating Horiz E " x 4 1/2" Slick Tube E14103 Horizontal Mullion E14106 Expansion Mullion (Female Half) E14107 Expansion Mullion (Male Half) E14108 Corner Mullion - Single Pocket E14109 Corner Mullion - Single Pocket E14110 Corner Mullion - Double Pocket E14124 Door Header - Single Pocket E14125 Door Header - No Pocket E14140 Open Back Horizontal E14141 Open Back Vertical E14142 Snap-In Filler - Shallow Pocket E14143 Horizontal Mullion E14144 Open Back Door Jamb With Pocket E14145 Door Jamb - Back To Back Doors E14240 Open Back Horizontal E14241 Open Back Vertical With Pocket E14242 Snap-In Filler With Pocket E " x 6" Door Header E " x 6" Open-back Sill E " x 6" OB Head, Jamb or Vertical E " x 6" Snap-in Filler with E14644 Pocket 2" x 6" Open-back Door Jamb E " x 6" Open-back Door Jamb E45005 Open Back 135 Degree Corner Mull /14/03 E14000SP.doc

61 MID AMERTCA TESTTNG LABORATORr tnc SIGNAL HILL DRIVE.CATAWISSA. MISSOURI63015 (636) Fpx(636) 257-s425 DATE OF REPORT: LOCATION OF TESTING: DATES OF ERECTION: DATES OF TESING: PRODUCT NAME: JOB NUMBER: CLIENT: March 24,2006 Mid America Testing Laboratory, Inc October l0-21,2005 November 8 * March I l, 2006 l Center Series 05107L-Center-THO Tubelite 'l-he following were present for all or portions of the specimen erection and testing: Mr. Steve DeYoung Mr. Les Olds Mr. Eric Kraus Mr. Travis Swisshelm Ms. Cindy Barrow Mr. Rick Heitmann Tubelite Tubelite St. Charles Glass Mid America Testing Laboratory Mid America Testing Laboratory Mid America Testins Laboratorv INTRODUCTION As requested Mid America Testing Laboratory provided a structural chamber for purposes of weatherization, structural and thermal testing on the Tubelite center system. The test unit rvas erected on site bv St. Charles Glass and Glazins under the direction of 'fubelite. UNIT DESCRIPTION The test unit was identified as a Tubelite T14000 Center Series and measured a nominal 8' wide X 8'high. A total of four (4) lites of glass were incorporated into the test specimen with the overall depth of the thermally broken system measuring 4 Yr" deep. The depth was equally created with the interior and exterior extrusions.

62 March 24,2006 T14000-Center THO FORMAL TESTING All tests were performed utilizing the base guidelines provided by Tubelite incorporaring the appropriate procedures outlined by AAMA and ASTM as referenced below: I. PRELOAD + I 5.0 PSF static pressure (50% of the positive design load for ten ( I 0) seconds). ALLOWED: RESULTS: No failure of the svstem No failure of the system The above result constitutes an acceptable performance. 2. STATIC AIR INFILTRATION (ASTM E283) at6.24 PSF (50 MPH wind and 1.2" H20). ALLOWED: RESULTS: 3.8 CFM gross leakage or.06 CFM pcr square foot. 3.0 CFM gross leakage or.047 CFM per square foot. 'fhe above results constitutc an acceptable performance. 3. STATIC WATER INFILTRATION (ASTM E33l) at 10.0 PSF (63 MPH wind and I.92" HzO) with a water spray rate of five (5) gallons per hour per square foot minimum for fifteen (15) minutes. ALLOWED: RESULTS; No uncontrolled water infiltration to thc room side. No uncontrolled water infiltration to the room side. The above result constitutes an acceptable performance'

63 March 24,2006 T14000-Center THO 4. STATIC WATER INFILTRATION (ASTM E33l) at tz.o psf' (69 MpH wind and 2.3" H2O) with a water spray rate of five (5) gallons per hour per square foot minimum for fifteen (15) minutes. ALLoWED: RESULTS: No uncontrolled water infiltration to thc room side. No uncontrolled water infiltration to the room side. The above result constitutes an acceptable performance. 5. DYNAMIC WATER TNFTLTRATION (AAMA 501. I ) with a I 00 MpH wind velocity at the prop creating a slip stream wind speed at the face of the wall of 69 Mpll at the wall equivalento 12.0 PSF. Water was applied at a rate of five (5) gallons per hour per square foot for fifteen (15) minutes. ALLOWED: RBSULTS: No uncontrolled water infiltration to the room side No uncontrolled water infiltration to the room side. The above result constitutes an acceptable performance. 6. STRUCTURAL DESIGN LOADING (ASTM E330) with each load being held fbr a duration often (10) seconds PSF ( 50% Positive Design Load) PSF (100% Positive Design Load) PSF ( 50% Negative Design Load) PSF (100% Negative Design Load) ALLOWED: No member shall have deflection greater than L/175 of its span or.37" vertically a.25" horizontally.

64 March 24,2006 T14000-Center THO RESULTS: No member exceeded the allowable deflection criteria with the maximum vertical deflection of.33" and maximum horizontal deflection of.15". The above results constitute an acceptable performance. 7. CONDENSATION RESISTANCE (AAMA ) with the temperatures being held for a period of two (2) hours after stabilization. Eight (8) sets of reading were taken at fifteen (15) minute intervals with averages used to calculate the CRF value. 'fhe following were the base conditions: Warm side ambient temperature: Cold side ambient temperature: lnterior humidity: Exterior wind speed: 68 degrees Fahrenheit 0 degrees Fahrenheit 35o l5 miles per hour Calculated CRF Value: 8. STATIC AIR INFILTRATION (ASTM E283) at6.24 PSF (50 MPH wind and 1.2" r r20). ALLOWED: RESULTS: 3.8 CFM gross leakage or.06 CI'M per square foot. There was no measurable change in the air infiltration as a result of the thermal testing. 'fhe above results constitute an acceptable performance. 9. STATIC WATER INFILTRATION (ASTM E33l ) at 12.0 PSF (69 MPH wind and 2.3" H:O) with a water spray rate of five (5) gallons per hour per square foot minimum for fifteen (15) minutes. ALLOWED: No uncontrolled water infiltration to the room side.

65 March 24,2006 T14000-Center TI{O RESULTS: 11o uncontrolled water infiltration to rhe room side. The above result constitutes an acceptable performance. l0 (AAMA 501.1) with a 100 MpH wind velocity at the prop creating a slip stream wind speed at the face of the wall of 6g MpH at the wall equivalento 12.0 PSF. Water was aiplied at a rate of five (5) gallons per hour per square foot for fifteen ( l5) minutes. ALLoWED: RESULTS: No uncontrolled water infiltration ro the room side. No uncontrolled water infiltration to the room side. The above result constitutes an acceptable performance. 1 l. STRUCTURAL PROOF LOADING (ASTM 8330) with each load being held for a duration often (10) seconds PSF ( 75% Positive Design Load) PSF ( 150% Positive Design Load) PSF (75% Negative Design Load) PSF (150% Negative Design Load) ALLOWED: RESULTS: No member shall have permanent set in excess of.zy of its span or shall therc be any failure of the system. No member exceeded the allowable permanent set or was there any {ailure of the system. The above results constitute an acceptable performance.

66 March 24,2006 T14000-Center THO SUMMARY: -fhc Tubelite T14000 Center system has met the desired levels of performance as clirected by the client. Should you have any questions regarding the information contained in this report please feel free to contact the laboratory. l'his document is valid for a period of four years from date of testing and may not be reproduced without permission of the testing laboratory. Respectful ly Submitted, Rick A. Heitmann President RAII:mm 'R-Ccntcr-l-l l0

Series B450 Guide Specification

Series B450 Guide Specification Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com STOREFRONT SERIES B450 Shear Block Air Infiltration:

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Aluminum entrance doors and frames. 2. Glass infill panels. 3. Door hardware. B. Related Sections:

More information

T series Storefront Framing Flush Glazed Thermally Broken Product Details

T series Storefront Framing Flush Glazed Thermally Broken Product Details Aluminum T-14650-series Storefront Framing Flush Glazed Thermally Broken Product Details Details: T-14650 series has a 2 sightline and is 6-1/2 deep. Utilizes a snap-in heavy duty CDM-32 door stop, which

More information

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division

More information

Heavy Commercial / Architectural Projected Windows Series L900T AW150

Heavy Commercial / Architectural Projected Windows Series L900T AW150 Heavy Commercial / Architectural Projected Windows Series L900T AW150 Section 08520...Aluminum Windows PART 1: WORK INCLUDED GUIDE SPECIFICATION A. The conditions of the contract and applicable sections

More information

7000 Series Curtain Wall Information Specifications

7000 Series Curtain Wall Information Specifications 7000 Series Curtain Wall Information Specifications Information All framing members shown in this section, unless noted otherwise, are stock items in dark bronze or clear anodic coatings and are available

More information

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication

More information

TMS 114 XT TECHNICAL MANUAL

TMS 114 XT TECHNICAL MANUAL TECHNICAL MANUAL BLANK PAGE FEATURES FEATURES is center set flush glazed systems that are 4 1/2" deep with a 2" wide sightline Glaze from the outside or inside Screw spline or shear block fabrication Glazing

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS 1. PART 1 GENERAL 1.1 WORK INCLUDED: 1. Provide labor, material, equipment and services to furnish and install aluminum windows shown on drawings and specified herein. Window

More information

TMW 450 TECHNICAL MANUAL

TMW 450 TECHNICAL MANUAL ARCHITECTURAL METALS, INC. TMW 450 TMW 450 TECHNICAL MANUAL TMW 450 ARCHITECTURAL METALS, INC. BLANK PAGE FEATURES ARCHITECTURAL METALS, INC. TMW 450 FEATURES TMW 450 is 6 3/4" deep with a 2" wide sightline

More information

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction SPECIFICATIONS: Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction GENERAL 1. SECTION INCLUDES 2. RELATED SECTIONS 3. QUALITY ASSURANCE A. General. B. Test Units. 1.

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS PART 1 GENERAL 1.1 SECTION INCLUDES A. Projected windows. B. Fixed windows. 1.2 RELATED SECTIONS A. Section 07900: Joint Sealers. B. Section 08400: Entrances and Storefronts.

More information

Specification Section Storefront Systems has been revised. Omit previously issued Storefront section.

Specification Section Storefront Systems has been revised. Omit previously issued Storefront section. December 28, 2018 ADDENDUM NO. 2 To: Re: Bidders Corey Pitts, NewQuest Properties This Addendum forms a part of the contract documents identified above. Acknowledge the receipt of this Addendum on the

More information

MPG Series 2250T Thermally Broken Aluminum Window

MPG Series 2250T Thermally Broken Aluminum Window SECTION 08520 ALUMINUM WINDOWS P a g e 1 MPG Series 2250T Thermally Broken Aluminum Window PART 1 GENERAL 1.01 Work Included A. Furnish and install aluminum architectural windows complete with hardware

More information

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc. Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT Report Number: C0271.01-450-44 Rendered to: Tubelite Inc. Walker, Michigan MODEL DESIGNATION: 400 Series Curtainwall with 4 Sided SSG PRODUCT

More information

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS This suggested guide specification has been developed using

More information

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window DIVISION 08 / SECTION 08505 METAL WINDOWS SILVER LINE BUILDING PRODUCTS SPECIFICATIONS: GENERAL Series 1700 Heavy Commercial Aluminum Double Hung 1. SECTION INCLUDES 2. RELATED SECTIONS 3. QUALITY ASSURANCE

More information

Guide Specification for Pre-Engineered Skylight System. A. Engineering, design and drafting of the entire skylight system.

Guide Specification for Pre-Engineered Skylight System. A. Engineering, design and drafting of the entire skylight system. Guide Specification for Pre-Engineered Skylight System SECTION 08630 - METAL FRAMED SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Engineering, design and drafting of the entire skylight system. B.

More information

MOCK-UP TEST REPORT. Report No: NCTL Test Dates:06/22, 07/23-27/10 Test Dates: 08/23-25/10 Report Date: 08/26/10

MOCK-UP TEST REPORT. Report No: NCTL Test Dates:06/22, 07/23-27/10 Test Dates: 08/23-25/10 Report Date: 08/26/10 MOCK-UP TEST REPORT Report No: NCTL-110-11828-3 Test Dates:06/22, 07/23-27/10 Test Dates: 08/23-25/10 Report Date: 08/26/10 Client: Alumil N.A. Corporation 4401 21 st. Street, Suite 203 Long Island City,

More information

SILVER LINE BUILDING PRODUCTS

SILVER LINE BUILDING PRODUCTS DIVISION 08 / SECTION 08560, VINYL WINDOWS SILVER LINE BUILDING PRODUCTS SPECIFICATIONS: 2200/2300/2600 Vinyl Single Hung Windows R50/R30 Performance for New Construction GENERAL 1. SECTION INCLUDES 2.

More information

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM SECTION 07400 TERRA COTTA CLAY TILE RAINSCREEN SYSTEM PART 1 GENERAL 1.01 WORK INCLUDED A. The terra cotta clay tile elements and aluminum support system shall be manufactured by NBK Keramik GmbH as represented

More information

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction SPECIFICATIONS: Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction GENERAL 1. SECTION INCLUDES 2. RELATED SECTIONS 3. QUALITY ASSURANCE A. General. B. Test Units. 1.

More information

4600 Series Specifications (Section 08520)

4600 Series Specifications (Section 08520) 4600 Series Specifications (Section 08520) I. GENERAL: 1.01 Scope of Work A. Furnish all necessary materials, labor, and equipment for the complete installation of aluminum windows for this project as

More information

North Hanover Township School District North Hanover Township, New Jersey

North Hanover Township School District North Hanover Township, New Jersey SECTION 084413 - GLAZED ALUMINUM CURTAIN WALLS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

TMS 152 / 152T / 152XT TECHNICAL MANUAL

TMS 152 / 152T / 152XT TECHNICAL MANUAL TMS 152 / 152T / 152XT TECHNICAL MANUAL BLANK PAGE FEATURES FEATURES TMS 152 (non-thermal), 152T (single thermal barrier), and 152XT (double thermal barrier) are front set flush glazed systems that are

More information

CTB Commercial Aluminum Window

CTB Commercial Aluminum Window Technical Information Description The is thermally-broken for use in commercial construction. Basic models include horizontal slider, single hung and fixed picture windows. Units are mulled together with

More information

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM 1. General 1.1 Description of Work a. Furnish the labour, materials and other services to complete the fabrication and installation of Thermo 3 Series framing, including all materials and fitments required

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL TEchnical bulletin PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION.......................................................................

More information

MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series

MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series SECTION 08520 ALUMINUM WINDOWS P a g e 1 MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series PART 1 GENERAL 1.01 Work Included A. Furnish and install aluminum architectural windows

More information

1600 WALL SYSTEM 2 ESTIMATING/TAKE-OFF AND ORDERING GUIDE (16 Pages) E.C.# (09/09/13)

1600 WALL SYSTEM 2 ESTIMATING/TAKE-OFF AND ORDERING GUIDE (16 Pages) E.C.# (09/09/13) 1600 WALL SYSTEM 2 ESTIMATING/TAKE-OFF AND ORDERING GUIDE 162-904 (16 Pages) E.C.#95449-095 (09/09/13) KAWNEER COMPANY, INC., 2006 1600 WALL SYSTEM 2 INDEX PAGE PARTS IDENTIFICATION ---------------------------

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 08 51 69.11 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels SPECIFICATIONS FOR (1/13 Edition) CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System Section 074243 Aluminum Composite Panels (Based upon CEI Composite Materials R4000

More information

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS This suggested guide

More information

Series x Thermal Triple Set Storefront Framing

Series x Thermal Triple Set Storefront Framing Series 433 2 x 4 1 2 Thermal Triple Set Storefront Framing CONFIGURATIONS Screw Spline Shear Block System 433 is a thermally broken storefront framing system. Glass planes can be placed in an outside set,

More information

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS PART 1 GENERAL SECTION 08 1116 ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS 1.01 SECTION INCLUDES A. Aluminum-framed storefront, with vision glass. B. Infill panels of glass. C. Aluminum doors

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required

More information

SECTION STAINLESS STEEL WALL PANELS

SECTION STAINLESS STEEL WALL PANELS SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.

More information

MARCH, 2017 Trifab 451UT Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs

MARCH, 2017 Trifab 451UT Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs MARCH, 2017 Trifab 451UT Framing 1 EC 97909-088 084113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS This suggested guide specification

More information

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors 2000/2100/2200 Series Heavy Commercial Sliding Patio Doors MANKO WINDOW SYSTEMS, INC. 800 HAYES DRIVE MANHATTAN, KANSAS 66502 PHONE: (800) 642-1488 (785) 776-9643 FAX: (800) 576-2656 (785) 776-9644 MANKO

More information

GUIDE SPECIFICATIONS - SECTION ALUMINUM WINDOWS Manko Window Systems Inc SERIES (Single Hung)

GUIDE SPECIFICATIONS - SECTION ALUMINUM WINDOWS Manko Window Systems Inc SERIES (Single Hung) GUIDE SPECIFICATIONS - SECTION 085210 ALUMINUM WINDOWS Manko Window Systems Inc. 7041 SERIES (Single Hung) SECTION 085210 ALUMINUM WINDOWS (Single Hung) PART 1 GENERAL 1.01 SUMMARY A. Section Includes:

More information

SECTION METAL WALL PANEL SYSTEM

SECTION METAL WALL PANEL SYSTEM CSI Format for Metal Wall Panel System Specification SECTION 07410 METAL WALL PANEL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior Metal Plate Wall Panels B. Substructure and Framing C. Structural

More information

SECTION ALUMINUM CURTAIN WALL PART 1 - GENERAL

SECTION ALUMINUM CURTAIN WALL PART 1 - GENERAL SECTION 08921 - ALUMINUM CURTAIN WALL PART 1 - GENERAL 1.01 DESCRIPTION A. Work of this section is subject to requirements of the Contract Documents including the General Conditions and Supplementary Conditions

More information

SOTA HYBRID-WALL SPECIFICATION FOR PRE-GLAZED & UNITIZED HYBRID-WALL SYSTEM

SOTA HYBRID-WALL SPECIFICATION FOR PRE-GLAZED & UNITIZED HYBRID-WALL SYSTEM 1. General 1.1 Description of Work a. Furnish the labour, materials and other services to complete the fabrication and installation of Hybrid-Wall Series framing, including all materials and fitments required

More information

ESTIMATING/TAKE-OFF AND ORDERING GUIDE

ESTIMATING/TAKE-OFF AND ORDERING GUIDE MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL 1 ESTIMATING/TAKE-OFF AND ORDERING GUIDE 2 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 INDEX PAGE PART IDENTIFICATION ------------------------------------------------------------

More information

SPECIFICATIONS SECTION 08600

SPECIFICATIONS SECTION 08600 PART 1 GENERAL 1.1 SECTION INCLUDES A. Design, engineering, production drawings, and documents. Detailed design and attachment of metal-framed skylight will be provided as noted in the following specifications.

More information

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows as

More information

SWING DOOR SPECIFICATION

SWING DOOR SPECIFICATION SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified

More information

SECTION B3 SERIES COS451 FRONT GLAZED STACKING SYSTEM

SECTION B3 SERIES COS451 FRONT GLAZED STACKING SYSTEM SECTION B SERIES COS51 FRONT GLAZED STACKING SYSTEM for STOREFRONT / WINDOW WALL x ½ for 1 GLASS ARCHITECTURAL DETAILS EXTERIOR GLAZED Effective October 01 www.cardcompro.com 1 INTERIOR GLAZED www.cardcompro.com

More information

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames.

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames. SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Aluminum doors and window wall frames. B. Related Sections: 1. Section 08480 Balanced Doors 2. Section

More information

E-Wall System 5800, 5800-I

E-Wall System 5800, 5800-I Windows Curtain Walls Entrances Storefronts E-Wall System 5800, 5800-I The beauty of EFCO s E-Wall Silicone Gasket curtain wall system is the simplicity in which it is installed. There are no internal

More information

Model 8000 Double Hung H-C x 2311 (56 x 91 )

Model 8000 Double Hung H-C x 2311 (56 x 91 ) 1.00 GENERAL PROVISIONS: PART 1 - GENERAL A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work with that of all construction contractors

More information

SPECIFICATION GUIDE SERIES 800 HEAVY PICTURE WINDOW

SPECIFICATION GUIDE SERIES 800 HEAVY PICTURE WINDOW SERIES 800 HEAVY PICTURE WINDOW Page 1 of 6 SPECIFICATION GUIDE SERIES 800 HEAVY PICTURE WINDOW www.ramwindows.com RAM Windows Series 800 Heavy Picture window is a custom residential and commercial window

More information

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS SECTION E INDEX CURTAINWALL FRAMING SYSTEMS E PAGE DESCRIPTION 0 CURTAINWALL FRAMING SPECIFICATION 0 SERIES /" () WIDE THERMALLY IMPROVED CURTAIN WALL FRAMING SYSTEM FOR SEALED UNIT GLAZING. 00 SERIES

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND CURTAINWALL

SECTION ALUMINUM-FRAMED ENTRANCES AND CURTAINWALL SECTION 084116 - ALUMINUM-FRAMED ENTRANCES AND CURTAINWALL PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Exterior and interior curtainwall framing. 2. Curtainwall framing for punched openings. 3.

More information

2018 Special-Lite ALUMINUM FRAMING

2018 Special-Lite ALUMINUM FRAMING 201 Special-Lite ALUMINUM FRAMING Framing Aluminum Framing Better materials and construction make our framing more durable. The frame is the foundation of any entrance. It must be capable of holding the

More information

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD) T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD) FEATURES 1.) Available Configurations -Single hung -Oriel style (optional) 2.) Main frame / Sash -Drop-in glazing

More information

Model 2000 IM Single Hung H-HC x 2500 (60 x 96 )

Model 2000 IM Single Hung H-HC x 2500 (60 x 96 ) 1.00 GENERAL PROVISIONS: PART 1 - GENERAL A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work with that of all construction contractors

More information

SECTION C1. SERIES CWW451T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM 2" X 4 1 /2" for 1" GLAZING ARCHITECTURAL DETAILS

SECTION C1. SERIES CWW451T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM 2 X 4 1 /2 for 1 GLAZING ARCHITECTURAL DETAILS SECTION C1 SERIES CWW51T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM " X 1 /" for 1" GLAZING ARCHITECTURAL DETAILS EXTERIOR GLAZED Effective October 01 www.cardcompro.com 1 INTERIOR GLAZED

More information

United Window & Door - Series 5500 New Construction Double Hung Windows Specifications

United Window & Door - Series 5500 New Construction Double Hung Windows Specifications United Window & Door - Series 5500 New Construction Double Hung Windows Specifications Part 1 GENERAL 1.01 INCLUSIONS 1. All windows as called for in this specification will be furnished with all necessary

More information

Model 2000 Single Hung H-HC x 2515 (60 x 99 )

Model 2000 Single Hung H-HC x 2515 (60 x 99 ) Architect to edit the items in red. PART 1 - GENERAL 1.01 GENERAL PROVISIONS: A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work

More information

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08410

More information

System Curtain Wall Thermally Improved System

System Curtain Wall Thermally Improved System Windows Curtain Walls Entrances Storefronts System 5900 2 1 2 Curtain Wall Thermally Improved System Configurations Outside Glazed Inside Glazed 2 or 4-sided Structural Silicone Glazed The 5900 curtain

More information

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1 Fitness Facility Addition Page 1 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Extruded aluminum windows with fixed sash..2 Factory glazed..3 Perimeter sealant. 1.2 RELATED SECTIONS.1 Section 05500 - Metal Fabrications.2

More information

YSD 700H PRODUCT DATA

YSD 700H PRODUCT DATA SYSTEM DESCRIPTION: The ProTek YSD 700 sliding glass door is designed to provide protection from the fierce cyclical pressures and projectiles associated with hurricane force winds. The engineering behind

More information

SECTION GLAZED ALUMINUM CURTAIN WALLS PART 1 GENERAL 1.01 RELATED DOCUMENTS

SECTION GLAZED ALUMINUM CURTAIN WALLS PART 1 GENERAL 1.01 RELATED DOCUMENTS SECTION 08 4413 - PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SECTION / METAL FRAMED SKYLIGHTS

SECTION / METAL FRAMED SKYLIGHTS Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) Format, including MasterFormat, SectionFormat, and PageFormat, contained in the

More information

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC. Architectural Testing AAMA 1503-09 THERMAL PERFORMANCE TEST REPORT Rendered to: TUBELITE, INC. SERIES/MODEL: 300ES Curtainwall (8" System) TYPE: Glazed Wall Systems (Site-built) Summary of Results Thermal

More information

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT SECTION 085200 - WOOD WINDOWS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A440-08

More information

SERIES 8510 AW-PG85-FW FIXED WINDOW

SERIES 8510 AW-PG85-FW FIXED WINDOW PART 1 - GENERAL 1.1 SCOPE OF WORK SERIES 8510 AW-PG85-FW FIXED WINDOW SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated

More information

FL550 21/2 x5 GUIDE SPECIFICATION. Impact-Resistant Storefront

FL550 21/2 x5 GUIDE SPECIFICATION. Impact-Resistant Storefront Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS This suggested guide

More information

SPECIFICATION SECTION PART 1 GENERAL

SPECIFICATION SECTION PART 1 GENERAL PART 1 GENERAL 1.01 Summary A. Furnish and install louvers, bird screens, blank-off panels, structural supports and attachment brackets as shown on the drawings, as specified, and as needed for a complete

More information

SERIES /8 SINGLE HUNG (CW50)

SERIES /8 SINGLE HUNG (CW50) SERIES 515 2-5/8 SINGLE HUNG (CW50) SPECIFICATIONS I. GENERAL: Scope of Work - Furnish all necessary materials, labor and equipment for the complete installation of aluminum windows for this project as

More information

SPECIFICATIONS...02-M3 TECHNICAL DATA...03-M3 TYPICAL DETAILS...04-M3 and 05-M3

SPECIFICATIONS...02-M3 TECHNICAL DATA...03-M3 TYPICAL DETAILS...04-M3 and 05-M3 0- Table of Contents SECTION PAGE SPECIFICATIONS...0- TECHNICAL DATA...0- TYPICAL DETAILS...0- and 0- Project: Private Condominiums, iami, FL Due to the diversity in state/provincial, local, and federal

More information

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08900 ALUMINUM CURTAIN WALL This suggested guide specification has

More information

Architectural Specification Manual

Architectural Specification Manual Architectural Specification Manual SteelBuilt Curtainwall INFINITY System The SteelBuilt Curtainwall Infinity System can use as a back mullion almost any type of custom steel member, such as stainless

More information

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002 SECTION 07 42 13 ALUMINUM PLATE PANEL SYSTEM ALPLY Insulated Panels Alply TECH WALL Aluminum Plate System 2002 PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Preformed Aluminum Plate System for Screen wall

More information

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8" AIR SPACE 3 1 2" SCALE = FULL SIZE

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8 AIR SPACE 3 1 2 SCALE = FULL SIZE Since 906 Series The Series is a heavy triple glazed church window incorporated into a " thermally broken frame. The thermal break is achieved with the use of Thermal Strip technology. Two different aluminum

More information

Series x Thermal Triple Set Storefront Framing

Series x Thermal Triple Set Storefront Framing Windows Curtain Walls Entrances Storefronts Series 433 2 x 4 1 2 Thermal Triple Set Storefront Framing Configurations Screw Spline Shear Block System 433 is a thermally broken storefront framing system.

More information

SERIES 2100 CW-PG60-FW FIXED WINDOW

SERIES 2100 CW-PG60-FW FIXED WINDOW PART 1 - GENERAL 1.1 SCOPE OF WORK SERIES 2100 CW-PG60-FW FIXED WINDOW SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated

More information

SERIES /8 HORIZONTAL SLIDING WINDOW (CW30)

SERIES /8 HORIZONTAL SLIDING WINDOW (CW30) SERIES 525 2-5/8 HORIZONTAL SLIDING WINDOW (CW30) I. GENERAL: SPECIFICATIONS Scope of Work - Furnish all necessary materials, labor and equipment for the complete installation of aluminum windows for this

More information

Section Aluminum Windows (2700 Model Specifications)

Section Aluminum Windows (2700 Model Specifications) Section 08520 - Aluminum Windows (2700 Model Specifications) I. GENERAL: 1.01 Scope of Work A. Furnish all necessary materials, labor, and equipment for the complete installation of aluminum windows for

More information

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA

More information

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows. SECTION 085113 - ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes fixed and operable aluminum-framed windows. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide aluminum windows capable

More information

Section Aluminum Windows (2700 Model Specifications)

Section Aluminum Windows (2700 Model Specifications) Section 08520 - Aluminum Windows (2700 Model Specifications) I. GENERAL: 1.01 Scope of Work A. Furnish all necessary materials, labor, and equipment for the complete installation of aluminum windows for

More information

K6746X Florida Product Approval No.: FL7708.2, UL Classified: R25376

K6746X Florida Product Approval No.: FL7708.2, UL Classified: R25376 LOUVER TYPE K6746X Florida Product Approval No.: FL7708.2, 15720.2 UL Classified: R25376 FLORIDA BUILDING CODE APPROVED DRAINABLE LOUVER Visible Mullion Louver Type... K6746X Material.... Extruded Aluminum

More information

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY)

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (DOOR ASSEMBLY)

More information

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA

More information

SECTION DETAILS (MECHANICALLY ASSEMBLY)

SECTION DETAILS (MECHANICALLY ASSEMBLY) COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (DOOR ASSEMBLY)

More information

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California TEST REPORT Report No.: G9949.01-303-47 Rendered to: CR LAURENCE CO., INC. Vernon, California PRODUCT TYPE: Fixed Lite Storefront System SERIES/MODEL: IT451 Title Summary of Results Design Pressure ±1440

More information

PART IDENTIFICATION...

PART IDENTIFICATION... 2 1600 WALL SYSTEM 4 INDEX JUNE, 2010 E.C. 95468-36 PAGE PART IDENTIFICATION............................. 3, 4 MATERIAL TAKE-OFF GUIDE....................... 5 PERIMETER DETAILS..............................

More information

PERFORMANCE TEST REPORT. Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly

PERFORMANCE TEST REPORT. Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly PERFORMANCE TEST REPORT Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly Title Summary of Results Air Infiltration

More information

Model 2000 BR Single Hung H-HC x 2500 (60 x 96 )

Model 2000 BR Single Hung H-HC x 2500 (60 x 96 ) 1.00 GENERAL PROVISIONS: PART 1 - GENERAL A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work with that of all construction contractors

More information

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope. SECTION 08 4519 - POLYCARBONATE WALL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior System: The design, manufacture and installation of an aluminum and polycarbonate insulating translucent system.

More information

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT SUMMARY. Rendered to:

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT SUMMARY. Rendered to: AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT SUMMARY Rendered to: AluminTechno LLC. 12 Selitskog Street, Room 211 FEZ Minsk, Minsk District, Minsk Region 220075 Republic

More information

DOUBLE HUNG SERIES 3500 AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.

DOUBLE HUNG SERIES 3500 AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com DOUBLE HUNG SERIES 3500 AAMA/WDMA/CSA

More information