Project Improvements to Roadside Sign Hardware and Design

Size: px
Start display at page:

Download "Project Improvements to Roadside Sign Hardware and Design"

Transcription

1 Project Improvements to Roadside Sign Hardware and Design PD: Doug Skowronek, P.E. (TRF) RS: Roger Bligh, Ph.D., P.E. (TTI) 86 th Annual Transportation Short Course October 17, 2012

2 Introduction 3-Year Project Research issues identified & prioritized by PD and PMC each FY Scope includes sign hardware Work plan, cost, & schedule developed for each research issue Research issues addressed in priority order based on available resources

3 Advisory Panel Karl Janak (CST) Christina Gutierrez (CST) Armen Miskarov (BRG) Charlie Wicker (TRF) Bryan Reed (LBB) Larry Colclasure (WAC) Carlos Ibarra (ATL) Wade Odell (RTI)

4 Research Topics Guidance for Minimum Sign Area for Slip Base Supports Mounting Standards for Chevrons and Mile Markers Analysis of Reported U Bracket Failures on Schedule 80 Pipe Supports Analysis of Wind-Induced Failures of Large Guide Signs Optimized Fuse Plates for Large Guide Signs Evaluation of Stiffeners on Extruded Aluminum Sign Panels Use of Schedule 40 pipe as Intermediate Small Sign Support Sign Capacity of Single Schedule 80 Pipe Support

5 Guidance for Minimum Sign Area for Slip Base Supports

6 Background Current TxDOT Slip Base System: 10 BWG (0.134 thick) A sign 16 ft 2 Sch 80 (0.276 thick) A sign 32 ft 2 NO min sign area requirement w/ slip base (signs as small as 4 ft 2 on Sch 80) Recent testing of small signs on - Lower center of mass and mass moment of slip bases has raised concern inertia - Decreases point of rotation - Increases rotational velocity - Higher probability for secondary contact - Observed Occupant Compartment Deformation (roof ) 5 6 inches MASH - Occ. Comp. Def. 4

7 Research Approach Conduct FEA Parametric Study of Impact Performance of Slip Base Support ft 2 A sign BWG-10, Sch 80, Sch 40 Pipe Supports Plain and T-Bracket Pipes 1100C (Passenger Car) and 2270P (Pickup-Quad Cab) Vehicles Perform Crash Tests for Verification of Impact Performance

8 Full-Scale Crash Tests 12 ft 2 A sign BWG-10 Support T-Bracket 7 Mounting Height MASH Criteria 2270P Pickup-Quad Cab Roof Impact, Occ. Comp. Def.: C Passenger Car Roof Impact, Occ. Comp. Def.: 4.75

9 Full-Scale Test Increased Sign Area 1100C Passenger Car 14 ft 2 A sign, 7 Mounting Height BWG-10 Support Roof Impact, Occ. Comp. Def.: 2.5

10 Full-Scale Crash Test (Pass)

11 Full-Scale Crash Test (Fail)

12 Recommendations Sign Area (ft 2 ) System Nominal Diameter (in) Pole Type 0-14 Wedge and Socket 2 BWG Slip Base 2.5 BWG Slip Base 2.5 Sch-80

13 Summary Identified Minimum Sign Area for Slip Base Sign Support Systems (14 ft 2 ) Provides Increased Safety for Motorists Implementation by TRF through Revision of SMD Sheets

14 Analysis of Wind-Induced Failures of Large Guide Signs

15 Failures Reported by Districts Numerous failures reported across the state Majority clustered in NE & West Texas Districts Repeated failures at many locations

16 Failure Modes Bending of Post

17 Analysis Results Existing Guidelines Overestimate Capacity of Some Supports Guidelines base on post bending capacity Fuse plate controls capacity in many instances e.g. W6x9 vs W6x12 New Wind Load Charts Required Fully account for all failure modes

18 Current Sign Support Selection Chart (90 MPH)

19 New Sign Support Selection Chart A (90MPH)

20 New Sign Support Selection Chart B (90MPH)

21 Summary Current Guidelines Overestimate Capacity of Some Large Guide Sign Supports Resulted in numerous wind-induced fuse plate failures New Wind Load Charts Developed 70, 80, and 90mph Reduced Maintenance Costs Fewer failures Implementation by TRF through revision of SMD Sheets

22 Evaluation of Stiffeners on Extruded Aluminum Sign Panels

23 Objective Analyze Need for Vertical Stiffeners on Extruded Aluminum Sign Panels Service (wind) loads Impact loads activation of slip base

24 Current Stiffener Details Stiffener Details S3x5.7 Within 6 of support post Midspan for large post spacing Attach to sign time intensive Requires large number of fasteners Must be assembled in sequence Reported injury to TxDOT Employee by falling stiffener

25 Static Testing

26 Capacity With and Without Stiffeners

27 Summary Vertical Stiffeners Not Required on Extruded Aluminum Sign Panels Significant cost savings Improved installation safety for sign crews Stiffeners (Permanent or Temporary) Can be Used to Assist with Handling and Installation Implementation by TRF through Revision of SMD sheets

28 Revised D&OM Standards

29

30 Full-Scale Crash Test (TWT)

31 Questions?

DEVELOPMENT OF A CRASWORTHY SUPPORT SYSTEM FOR LARGE TEMPORARY GUIDE SIGNS

DEVELOPMENT OF A CRASWORTHY SUPPORT SYSTEM FOR LARGE TEMPORARY GUIDE SIGNS TRB 14-4791 DEVELOPMENT OF A CRASWORTHY SUPPORT SYSTEM FOR LARGE TEMPORARY GUIDE SIGNS by R. P. Bligh and D. R. Arrington Word Count: 5075 + (2 tables + 8 figures @ 250/ea) = 7575 Submission Date: August

More information

SYNTHESIS OF THE PERFORMANCE OF PORTABLE CONCRETE BARRIER SYSTEMS

SYNTHESIS OF THE PERFORMANCE OF PORTABLE CONCRETE BARRIER SYSTEMS Project No. 22-36 Copy No. SYNTHESIS OF THE PERFORMANCE OF PORTABLE CONCRETE BARRIER SYSTEMS PRELIMINARY DRAFT FINAL REPORT Prepared for National Cooperative Highway Research Program Transportation Research

More information

B-RAIL SPAN CHART REPORT

B-RAIL SPAN CHART REPORT B-RAIL SPAN CHART REPORT for State of California Prepared For: Orion Solar Racking Orion Solar Racking 2917 Vail Ave. Commerce, CA 90040 RE: Sunstrong Structural Compliance Report of Orion Solar Racking

More information

Sheikh et al. 1 PINNED-DOWN TEMPORARY CONCRETE BARRIER WITH TRANSITION SYSTEMS FOR LIMITED-SPACE WORK ZONE APPLICATIONS

Sheikh et al. 1 PINNED-DOWN TEMPORARY CONCRETE BARRIER WITH TRANSITION SYSTEMS FOR LIMITED-SPACE WORK ZONE APPLICATIONS Sheikh et al. 1 PINNED-DOWN TEMPORARY CONCRETE BARRIER WITH TRANSITION SYSTEMS FOR LIMITED-SPACE WORK ZONE APPLICATIONS Nauman M. Sheikh Texas A&M Transportation Institute Texas A&M University System MS-3135

More information

Just Makes Cents... Per Watt. Compliance Report Composition L-Foot Kit State of California September 25th SOLARACK INC.

Just Makes Cents... Per Watt. Compliance Report Composition L-Foot Kit State of California September 25th SOLARACK INC. Just Makes Cents... Per Watt Compliance Report Composition L-Foot Kit State of California September 25th 2017 5062 Lankershim Blvd Suite # 418 North Hollywood, CA 91601 RE: Sunstrong Structural Compliance

More information

TEST REPORT. Rendered to: COLLINS LIMITED, LLC. For:

TEST REPORT. Rendered to: COLLINS LIMITED, LLC. For: TEST REPORT Rendered to: COLLINS LIMITED, LLC For: 48 in Rook Post Mount and Structural Post Assembly Report No: Report Date: 03/11/10 130 Derry Court York, PA 17406-8405 phone: 717-764-7700 fax: 717-764-4129

More information

SUBJECT: Discussion Regarding Barriers & Barrier Transitions with Staff from the Midwest Roadside Safety Facility (Univ of Nebraska, Lincoln)

SUBJECT: Discussion Regarding Barriers & Barrier Transitions with Staff from the Midwest Roadside Safety Facility (Univ of Nebraska, Lincoln) Problem # 8 MnDOT Questions Regarding Bridge Barriers State Question and MwRSF Response: MnDOT had a conference call with MwRSF to discuss various questions regarding barriers on superelevations and cross

More information

John M. Holt, P.E. Transportation Short Course October 2012

John M. Holt, P.E. Transportation Short Course October 2012 What s Up With These New Bridge Rails? John M. Holt, P.E. Transportation Short Course October 2012 Agents of Change Outline Bridge Railing Manual New Rails T131RC, T1W, C1W, T1F, T66, Picket Rail, T80SS,

More information

Development of a Test Level 3 Transition Between Guardrail and Portable Concrete Barriers

Development of a Test Level 3 Transition Between Guardrail and Portable Concrete Barriers University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Civil Engineering Faculty Publications Civil Engineering 2017 Development of a Test Level 3 Transition Between Guardrail

More information

B-RAIL SPAN CHART REPORT

B-RAIL SPAN CHART REPORT B-RAIL SPAN CHART REPORT for State of California Prepared For: Orion Solar Racking April 1st 2014 April 1 2014 Orion Solar Racking 2917 Vail Ave. Commerce, CA 90040 RE: Sunstrong Structural Compliance

More information

Universal TAU-II Redirective, Non-Gating, Crash Cushion

Universal TAU-II Redirective, Non-Gating, Crash Cushion TB 010925 Rev. 2 Page 1 of 10 Product Specification Universal TAU-II Redirective, Non-Gating, Crash Cushion I. General The Universal TAU-II system is a Redirective, Non-Gating Crash Cushion in accordance

More information

American Residential Deck Railing Design Guide

American Residential Deck Railing Design Guide American Residential Deck Railing Design Guide Intended for use by Designers & Architects Engineers & Professional Installers 8 th Edition ProbuiltRailings.com TABLE OF CONTENTS ProBuilt Design Manual

More information

Design and Testing of an Easy to Use Pinned-down Temporary Concrete Barrier with Limited Deflections

Design and Testing of an Easy to Use Pinned-down Temporary Concrete Barrier with Limited Deflections 12 th International LS-DYNA Users Conference Automotive(1) Design and Testing of an Easy to Use Pinned-down Temporary Concrete Barrier with Limited Deflections Nauman M. Sheikh and Roger P. Bligh Texas

More information

Blast Curtain Wall Installation Analysis

Blast Curtain Wall Installation Analysis August 11, 2005 57402.01-122-34 JAR/STS 1 US Aluminum BR3250 Blast C.W. Blast Curtain Wall Installation Analysis Subject: BR3250 Blast Curtain Wall System ATI Report 57402.01-122-34 Rendered to: International

More information

BROCHURE TELESPAR MASSH

BROCHURE TELESPAR MASSH BROCHURE TELESPAR MASSH - 400 Multi-Directionally Activated Sign Support Hardware A PART OF MASSH-400 Multi-Directionally Activated Sign Support Hardware Telespar is proud to introduce the MASSH-400 ground

More information

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS for State of Colorado Prepared for: SolaRack Prepared By: November 12, 2018 1 SolaRack 1103 Lawrence Dr., Unit A Newbury Park, CA 91320 RE:

More information

Figure 5 - A shoring tower is made by assembling end frames with diagonal braces

Figure 5 - A shoring tower is made by assembling end frames with diagonal braces Figure 5 - A shoring tower is made by assembling end frames with diagonal braces Figure 6 shows shoring towers being used in the construction of the new Computer Science building at the University of Washington

More information

Section 13. Guidelines for the Design of Ground Mounted Sign Supports

Section 13. Guidelines for the Design of Ground Mounted Sign Supports Section 13 BDC11MR-04 13.1 Introduction Highway signs fall into two main categories, which are subdivided as follows: 1. Overhead Signs a. Sign Bridge Structures (GO) b. Sign Cantilever Structures (GO)

More information

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS for State of California Prepared for: SolaRack Prepared By: November 12, 2018 1 SolaRack 1103 Lawrence Dr., Unit A Newbury Park, CA 91320

More information

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS for State of South Carolina Prepared for: SolaRack Prepared By: December 12, 2018 1 SolaRack 1103 Lawrence Dr., Unit A Newbury Park, CA 91320

More information

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS for State of Utah Prepared for: SolaRack Prepared By: October 30, 2018 1 SolaRack 1103 Lawrence Dr., Unit A Newbury Park, CA 91320 RE: Sunstrong

More information

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION.  T.A. Morrison & Co. Inc. 1 SUBMITTAL DATA Series 9000 BF Thermally Insulated Damper with Thermally Broken Frames & Blades SP Standard Profile Flanged to Duct Install Type THERMAL BREAKS OPPOSED frame is 4 (101.6 mm) deep x 1 (25.4

More information

Barriers, Parapets, and Railings

Barriers, Parapets, and Railings Barriers, Parapets, and Railings Arielle Ehrlich State Bridge Design Engineer May 17, 2017 Bridge Office mndot.gov/bridge MnDOT Vocabulary Is it a barrier, a parapet or a railing? BARRIER. It is concrete

More information

MEMORANDUM. ~ ~ //. -L/'j L!E.

MEMORANDUM. ~ ~ //. -L/'j L!E. ~e* ~;~:~ent.,o.:-ransportation MEMORANDUM TO: All District Engineers DATE: September 28,2007 ~ ~ //. -L/'j L!E. FROIVI: Carlos A. Lopez, P.E. ~..t::o ce- V '1'~ r. SUBJECT: Revised Barricade and Construction

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT Page 230548-1 SECTION 230548 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

WIND SPEED AND DESIGN CRITERIA FOR FLEXIBLE FACE SIGNS CONSTRUCTED OF ABC EXTRUSIONS

WIND SPEED AND DESIGN CRITERIA FOR FLEXIBLE FACE SIGNS CONSTRUCTED OF ABC EXTRUSIONS WIND SPEED AND DESIGN CRITERIA FOR FLEXIBLE FACE SIGNS CONSTRUCTED OF ABC EXTRUSIONS 2005 EDITION This edition is based upon ASCE 7-98 recommendations for wind speed and wind loads. These have changed

More information

GroundTrac. Installation Manual

GroundTrac. Installation Manual APPLICATION: The GroundTrac system is designed with a minimum amount of installed footings at greatly reduced labor. The system integrates with ordinary 1-1/2 schedule #40 galvanized water pipe. This ground

More information

Steel Bridge Research at Ferguson Structural Engineering Lab

Steel Bridge Research at Ferguson Structural Engineering Lab Steel Bridge Research at erguson Structural Engineering Lab Investigators: Todd Helwig, Mike Engelhardt, Eric Williamson, Ozzie Bayrak, Tricia Clayton, John Tassoulas, and Lance Manuel Sponsor: Texas Department

More information

Product Specification ArmorGuard Barrier System

Product Specification ArmorGuard Barrier System TB 081030 Rev. 0 Page 1 of 6 Product Specification ArmorGuard Barrier System I. General The ArmorGuard Barrier System is a longitudinal barrier, as defined in the AASHTO Roadside Design Guide, which can

More information

Structural Analysis Report

Structural Analysis Report New York Connecticut Maryland Florida M. G. McLAREN, P.C. 578 Major Blvd Suite Orlando, Florida 389 Phone (407) 354-54 Fax (407) 354-3466 On the web: www.mgmclaren.com Structural Design Bridge & Highway

More information

Wind Science & Engineering Research Center Debris Impact Test Facility P.O. Box Lubbock, Texas MANUFACTURER S IDENTIFICATION

Wind Science & Engineering Research Center Debris Impact Test Facility P.O. Box Lubbock, Texas MANUFACTURER S IDENTIFICATION 1.0 MANUFACTURER S IDENTIFICATION 1.1 NAME OF APPLICANT: Western States Clay Products Assoc. 9780 S. 5200 W. West Jordan, Utah 84081 1.2 CONTACT PERSON: Mr. Jeff Elder 1.3 TEST LAB CERTIFICATION: Federal

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Montgomery County Specification Download Acknowledgement

Montgomery County Specification Download Acknowledgement Montgomery County Specification Download Acknowledgement Request for Bid or Proposal Project # 18-42 CALVARY ROAD RECONSTRUCTION PRECINCT 1 PLANS ONLY VENDORS MUST IMMEDIATELY RETURN THIS FORM BY EMAIL:

More information

TEST REPORT. Rendered to: SENTINEL FENCE AND RAIL. For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post

TEST REPORT. Rendered to: SENTINEL FENCE AND RAIL. For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post TEST REPORT Rendered to: SENTINEL FENCE AND RAIL For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post Report No: Report Date: 10/23/12 130 Derry Court York, PA 17406-8405

More information

ROADSIDE SAFETY BARRIER ELEMENTS Module 3

ROADSIDE SAFETY BARRIER ELEMENTS Module 3 2 ROADSIDE SAFETY BARRIER ELEMENTS Module 3 3 Roadside Design Options 4 Expected Crash Reduction of Relocation of Fixed Objects Source: NCHRP Report 500, Vol 6, Exhibit V-26 Purpose of Safety Barriers

More information

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following: SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN 1. SCOPE This specification covers the design, fabrication and testing of tubular section, galvanised steel friction fit jointed street light columns of

More information

ENERGY SECTOR CORRIDOR IMPROVEMENT PROGRAM

ENERGY SECTOR CORRIDOR IMPROVEMENT PROGRAM ENERGY SECTOR CORRIDOR IMPROVEMENT PROGRAM Randy C. Hopmann, P.E. Director of District Operations May 26, 2016 Texas Energy Sector plays 2 Corridor improvements Reinforce pavements on major corridors while

More information

Technical Report Documentation Page 2. Government Accession No. 3. Recipient's Catalog No.

Technical Report Documentation Page 2. Government Accession No. 3. Recipient's Catalog No. 1. Report No. FHWA/TX-15/5-9049-03-7 4. Title and Subtitle INSTALLATION OF DYNAMIC TRAVEL TIME SIGNS AND EFFORTS TO OBTAIN AND TEST A GRAPHICAL ROUTE INFORMATION PANEL (GRIP) SIGN IN AUSTIN Technical Report

More information

SECTION ROOF ACCESSORIES

SECTION ROOF ACCESSORIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 72 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

SECTION AWNINGS

SECTION AWNINGS SECTION 10 73 13 AWNINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Fixed metal awnings. 1.2 DEFINITIONS A. Awning: An architectural projection that provides weather protection,

More information

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window DIVISION 08 / SECTION 08505 METAL WINDOWS SILVER LINE BUILDING PRODUCTS SPECIFICATIONS: GENERAL Series 1700 Heavy Commercial Aluminum Double Hung 1. SECTION INCLUDES 2. RELATED SECTIONS 3. QUALITY ASSURANCE

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

Performance of the Midwest Guardrail System with Rectangular Wood Posts

Performance of the Midwest Guardrail System with Rectangular Wood Posts Duplication for publication or sale is strictly prohibited without prior written permission of the Transportation Research Board Paper No. 14-2991 Performance of the Midwest Guardrail System with Rectangular

More information

DMS HIGH MAST LIGHT FIXTURES

DMS HIGH MAST LIGHT FIXTURES DMS - 11020 EFFECTIVE DATE: JANUARY 2012 11020.1. Description. This specification governs the materials, composition, and quality of 400 watt (W) high pressure sodium (HPS) tenon-mounted high mast light

More information

Anchoring and Stiffening Techniques for Portable Concrete Barriers

Anchoring and Stiffening Techniques for Portable Concrete Barriers University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Mechanical (and Materials) Engineering -- Dissertations, Theses, and Student Research Mechanical & Materials Engineering,

More information

Stefano Lepre Dofasco Automotive Components. w w w. a u t o s t e e l. o r g

Stefano Lepre Dofasco Automotive Components. w w w. a u t o s t e e l. o r g TUBULAR DESIGN DEVELOPMENT AND APPLICATION OF HSLA AND DP600 STEELS, FOR THE REAR SUSPENSION STRUCTURE OF THE 2006 CADILLAC DTS AND BUICK LUCERNE Stefano Lepre Dofasco Automotive Components ABSTRACT The

More information

Case Study in Steel adapted from Structural Design Guide, Hoffman, Gouwens, Gustafson & Rice., 2 nd ed.

Case Study in Steel adapted from Structural Design Guide, Hoffman, Gouwens, Gustafson & Rice., 2 nd ed. Case Study in Steel adapted from Structural Design Guide, Hoffman, Gouwens, Gustafson & Rice., 2 nd ed. Building description The building is a one-story steel structure, typical of an office building.

More information

NOTES FOR QUADGUARD ELITE

NOTES FOR QUADGUARD ELITE CONTENTS NOTES FOR QUADGUARD ELITE DESCRIPTION DRAWING NO. SHEET NO. 1. The energy absorbing system represented on these Qualified Products List (QPL) drawings is a proprietary design by Energy Absorption

More information

APPLICATION OF A PRECAST CONCRETE BARRIER ADJACENT TO A STEEP ROADSIDE SLOPE

APPLICATION OF A PRECAST CONCRETE BARRIER ADJACENT TO A STEEP ROADSIDE SLOPE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 APPLICATION OF A PRECAST CONCRETE BARRIER ADJACENT TO A STEEP ROADSIDE SLOPE Nauman M. Sheikh

More information

LOCATION AND DESIGN DIVISION

LOCATION AND DESIGN DIVISION VIRGINIA DEPARTMENT OF TRANSPORTATION LOCATION AND DESIGN DIVISION INSTRUCTIONAL AND INFORMATIONAL MEMORANDUM GENERAL SUBJECT: ROADWAY SAFETY FEATURES SPECIFIC SUBJECT: NCHRP 350 TEST REQUIREMENTS LOCATION

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION PRODUCT SPECIFICATION Part Name: PLASTICADE Modular Glare Screen System Description The Modular Glare Screen System is intended to be mounted to a barrier or median in order to delineate the barrier and

More information

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT Page 220548-1 SECTION 220548 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE ELECTRICAL SPECIFICATION 1453 DIVISION OF ENGINEERING DEPARTMENT OF TRANSPORTATION CITY OF CHICAGO REVISED MARCH 14, 2013 MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE SUBJECT 1. This specification covers

More information

Crash and Impact Strength Analysis of Structural component of the vehicle for Occupant Safety

Crash and Impact Strength Analysis of Structural component of the vehicle for Occupant Safety Crash and Impact Strength Analysis of Structural component of the vehicle for Occupant Safety Ms. Gauri B. Mahajan 1, Prof. Dinesh. N. Kamble 2 Abstract This paper describes a type of car s side impact

More information

FLAT TILE HOOK SPAN CHART

FLAT TILE HOOK SPAN CHART FLAT TILE HOOK SPAN CHART (WIND & SNOW CONSIDERED) for State of California Prepared For: Orion Solar Racking January 5 2014 January 5 2014 Orion Solar Racking 2917 Vail Ave. Commerce, CA 90040 RE: Span

More information

Best Practices Guidelines for Sign Materials

Best Practices Guidelines for Sign Materials Best Practices Guidelines for Sign Materials 1.0 Introduction 1.1 These guidelines are for standard sign applications. For locations that are deemed hazardous a detailed assessment is required and may

More information

Structural Performance of 8-inch NRG Concrete Masonry Units. Report Compiled for: Niagara Regional Group. Date: January 28, 2013

Structural Performance of 8-inch NRG Concrete Masonry Units. Report Compiled for: Niagara Regional Group. Date: January 28, 2013 Structural Performance of 8-inch NRG Concrete Masonry Units Report Compiled for: Niagara Regional Group Date: January 28, 2013 Report Prepared by: Dr. Shawn Gross, Associate Professor Dr. David Dinehart,

More information

Multi-Story Solid Tilt-Up Wall Panel Analysis and Design (ACI 551)

Multi-Story Solid Tilt-Up Wall Panel Analysis and Design (ACI 551) Multi-Story Solid Tilt-Up Wall Panel Analysis and Design (ACI 551) Span 1 Span 2 Span 3 Span 4 Reinforced Concrete Multi-Story Tilt-Up Wall Panel Analysis (ACI 551) Tilt-up is form of construction with

More information

EHH-601D. Miami-Dade Qualified Wind-Driven Rain Louver

EHH-601D. Miami-Dade Qualified Wind-Driven Rain Louver Application and Design is a Florida Product Approved and Miami-Dade Qualified stationary horizontal blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in

More information

Louisiana Transportation Research Center

Louisiana Transportation Research Center Louisiana Transportation Research Center Final Report 547 Performance and Analysis of Concrete Bridge Railing using Conventional and Composite Reinforcement Materials by Walid R. Alaywan, Ph.D., P.E. LTRC

More information

Portable Changeable Message signs have a wide variety of

Portable Changeable Message signs have a wide variety of Part 6F (devices) Minnesota MUTCD 2005 with 2007 09 Revisions Part 6F (devices) Federal MUTCD 2009 Part 6F (devices) MN MUTCD Rearranged Sections 6F.55 Portable Changeable Message Signs Portable Changeable

More information

NOTES ON THE SPECIFICATION FOR PROCUREMENT OF LIGHTING COLUMNS

NOTES ON THE SPECIFICATION FOR PROCUREMENT OF LIGHTING COLUMNS 1. INTRODUCTION This specification is to cover the performance, design, approval, fabrication, testing and installation of lighting columns of the direct ground planted and flange mounted types, for rigid

More information

PROJECT. The University of Akron. NASA Flight Readiness Review. 12 March 2018

PROJECT. The University of Akron. NASA Flight Readiness Review. 12 March 2018 PROJECT The University of Akron NASA Flight Readiness Review 12 March 2018 Rail Exit velocity of 23 Ft/s Corkscrew flight up to 960 Ft Ballistic crash landing near launch site The University of Akron College

More information

FINAL CONTRACT REPORT DETERMINATION OF REMAINING FATIGUE LIFE OF WELDED STUD DETAILS ON OVERHEAD ALUMINUM SIGN PANELS IN VIRGINIA

FINAL CONTRACT REPORT DETERMINATION OF REMAINING FATIGUE LIFE OF WELDED STUD DETAILS ON OVERHEAD ALUMINUM SIGN PANELS IN VIRGINIA FINAL CONTRACT REPORT DETERMINATION OF REMAINING FATIGUE LIFE OF WELDED STUD DETAILS ON OVERHEAD ALUMINUM SIGN PANELS IN VIRGINIA Jeremy L. Lucas Graduate Research Assistant Thomas E. Cousins, Ph.D., P.E.

More information

Wind Science & Engineering Research Center Debris Impact Test Facility P.O. Box Lubbock, Texas MANUFACTURER S IDENTIFICATION

Wind Science & Engineering Research Center Debris Impact Test Facility P.O. Box Lubbock, Texas MANUFACTURER S IDENTIFICATION 1.0 MANUFACTURER S IDENTIFICATION 1.1 NAME OF APPLICANT: Mason Greenstar P.O. Box 1420 Mason, Texas 76856 1.2 CONTACT PERSON: Mr. Zach Rabon 1.3 TEST LAB CERTIFICATION: Federal Emergency Management Agency

More information

SAMPLE TC6K Elevator Design Summary. Order No PO-47201

SAMPLE TC6K Elevator Design Summary. Order No PO-47201 SAMPLE TC6K Elevator Design Summary 900 RR 620 S., Ste C206 Austin TX 78734 (512) 266-6200 voice (512) 266-6210 fax SAMPLE CCR TC6K Elevator Design Summary - Elevator System Design Parameters Nominal Height

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 10/13/2016 Issued: 12/17/2014 Visit www.ati-es.com for current status Revised: 10/30/2015 Page 1 of

More information

Code Compliance Research Report CCRR-0187

Code Compliance Research Report CCRR-0187 Code Compliance Research Report CCRR-0187 Issue Date: 11-29-2012 Revision Date: 07-24-2018 Renewal Date: 02-28-2019 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 63 00 Plastic Railings REPORT

More information

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures Structural vs Nonstructural Members Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures Behavior of Cold-Formed Steel Members STEEL DESIGN SPECIFICATIONS Type of steel Specification

More information

LOCATION AND DESIGN DIVISION

LOCATION AND DESIGN DIVISION VIRGINIA DEPARTMENT OF TRANSPORTATION LOCATION AND DESIGN DIVISION INSTRUCTIONAL AND INFORMATIONAL MEMORANDUM GENERAL SUBJECT: ROADWAY SAFETY FEATURES SPECIFIC SUBJECT: NCHRP 350 TEST REQUIREMENTS LOCATION

More information

KNIGHT BOLLARD TECH BRIEF. T page 1 of 1 Rev

KNIGHT BOLLARD TECH BRIEF. T page 1 of 1 Rev KNIGHT BOLLARD KNIGHT BOLLARD TECH BRIEF PRODUCT DATA page 1 of 1 Rev. 09-14-18 Knight Bollards combine rustproof construction, a unique geometric design, and the striking aesthetic of the rest of the

More information

TEST REPORT ON. TESTED FOR: Metal Roofing Systems, Inc Mikron Drive Stanley, NC Telephone: (704) FAX: (704)

TEST REPORT ON. TESTED FOR: Metal Roofing Systems, Inc Mikron Drive Stanley, NC Telephone: (704) FAX: (704) TEST REPORT ON METAL ROOFING SYSTEMS INC. SYSTEM 2500 ROOF PANELS (24 GA., 2" HIGH, 16 WIDE FLAT PAN PANEL) AT 1' 0" & 5' 0" PURLIN SPACING WITH 180º SEAM IN ACCORDANCE WITH ASTM E1592-05 TESTED FOR: Metal

More information

RAILING DESIGN FOR NEW TRUSS BRIDGES. Texas Transportation Institute The Texas A&M University System College Station, Texas

RAILING DESIGN FOR NEW TRUSS BRIDGES. Texas Transportation Institute The Texas A&M University System College Station, Texas 1. Report No. FHWA/TX-05/0-4419-4 4. Title and Subtitle RAILING DESIGN FOR NEW TRUSS BRIDGES 2. Government Accession No. 3. Recipient's Catalog No. Technical Report Documentation Page 5. Report Date October

More information

SHRC SHELTERS STACI CUCCIO, FLINT HOLBROOK, KEVIN ROEWE, & JARED SWART

SHRC SHELTERS STACI CUCCIO, FLINT HOLBROOK, KEVIN ROEWE, & JARED SWART SHRC SHELTERS STACI CUCCIO, FLINT HOLBROOK, KEVIN ROEWE, & JARED SWART MISSION Create safe economical shelter designs Design outstanding features Satisfy client & market demands PROBLEM STATEMENT Storm

More information

Page 10-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LIGHTING AND SIGNS

Page 10-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LIGHTING AND SIGNS Page 10-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 FOUNDATION SYSTEM SECTION 10 CONTENTS INTRODUCTION... 10-3 PRODUCT BENEFITS... 10-3 RECOMMENDED FACTORS of SAFETY for DESIGN...

More information

Texas Transportation Institute The Texas A&M University System College Station, Texas

Texas Transportation Institute The Texas A&M University System College Station, Texas 1. Report No. FHWA/TX-04/0-1816-1 2. Government Accession No. 3. Recipient's Catalog No. Technical Report Documentation Page 4. Title and Subtitle EVALUATION OF ROADSIDE SAFETY DEVICES USING FINITE ELEMENT

More information

Mounting Bases and Vibration Isolation. for Greenheck Centrifugal Fans GREENHECK

Mounting Bases and Vibration Isolation. for Greenheck Centrifugal Fans GREENHECK Mounting Bases and Vibration Isolation for Greenheck Centrifugal Fans GREENHECK September 1997 MOUNTING BASES AND VIBRATION ISOLATION for Greenheck Centrifugal Fans This catalog outlines the types of bases

More information

Design and Full-Scale Crash Testing of an Anchored Temporary Concrete Barrier and its Transition System for Use on Asphalt Pavement

Design and Full-Scale Crash Testing of an Anchored Temporary Concrete Barrier and its Transition System for Use on Asphalt Pavement 0 0 0 0 Design and Full-Scale Crash Testing of an Anchored Temporary Concrete Barrier and its Transition System for Use on Asphalt Pavement By Chiara Silvestri Dobrovolny *, Nauman M. Sheikh, Paul B. Fossier,

More information

I. Selection Procedure for DOUBLE PLUS, Outboard Roller and Top Roller Chain

I. Selection Procedure for DOUBLE PLUS, Outboard Roller and Top Roller Chain I. Selection Procedure for DOUBLE PLUS, Outboard Roller and Top Roller 1) Confirmation of operating conditions for free flow conveyor The following information is needed in order to select an appropriate

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF

More information

Introduction. Crossarm Design

Introduction. Crossarm Design SUBJECT BCTC 287kV H-Frame Crossarm Finite Element Analysis Report AUTHOR Jeremy Mostoller DATE August 4, 2008 Introduction This report details the analysis and optimization of the glass fiber reinforced

More information

TXDOT SIGNING AND MARKINGS REVIEW OF MATERIALS & PRACTICES

TXDOT SIGNING AND MARKINGS REVIEW OF MATERIALS & PRACTICES TXDOT SIGNING AND MARKINGS REVIEW OF MATERIALS & PRACTICES Table of Contents 1 2 3 4 5 6 7 Introduction Traffic Marking Specifications Traffic Marking Practices Signing Specifications Retroreflective Sheeting

More information

New Jersey Turnpike Authority

New Jersey Turnpike Authority New Jersey Turnpike Authority DOCUMENT UPDATE REQUEST Forward to Assistant Chief Engineer, Design Initiator Russell Saputo, PE Submittal Date 6/21/16 Firm Stantec Consulting Services Inc. Telephone 201-587-9040

More information

Uses of Abaqus/Standard in Failure Analysis

Uses of Abaqus/Standard in Failure Analysis Uses of Abaqus/Standard in Failure Analysis Matthew T. Kenner, P.E., John A. Wilkinson, P.E., Michael E. Stevenson, Ph.D., P.E., and Michael D. Hayes, Ph.D., P.E. Engineering Systems Inc. www.esi-website.com

More information

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT SUMMARY. Rendered to:

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT SUMMARY. Rendered to: AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT SUMMARY Rendered to: AluminTechno LLC. 12 Selitskog Street, Room 211 FEZ Minsk, Minsk District, Minsk Region 220075 Republic

More information

Height Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w

Height Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w Series Optics Mounting Lamping / Wattage Finish Voltage SAMG Saturn Magnum MR Type V MTR* 6 Refractor Refractor is an integral part of the fixture and is not an option. Project: Type: SAMG MR Series Optics

More information

SECTION ALUMINUM GATES

SECTION ALUMINUM GATES P.O. Box 1058 370 South Athol Rd. Athol, Massachusetts 01331 Phone: (978) 249-7924 Fax: (978) 249-3072 SECTION ALUMINUM GATES PART 1 GENERAL 1.01 SCOPE OF WORK A. The CONTRACTOR shall furnish all labor,

More information

ANAYSIS OF THE COMPOSITE STRUCTURE OF TILTING TRAIN EXPRESS(TTX)

ANAYSIS OF THE COMPOSITE STRUCTURE OF TILTING TRAIN EXPRESS(TTX) ANAYSIS OF THE COMPOSITE STRUCTURE OF TILTING TRAIN EXPRESS(TTX) Soo-Hyun Kim, Sang-Guk Kang, Chun-Gon Kim 1 and Kwang-Bok Shin 2 1 Division of Aerospace Engineering, Korea Advanced Institute of Science

More information

Subject: ACTION: National Cooperative Highway Research Program (NCHRP) Report 350 Hardware Compliance Dates

Subject: ACTION: National Cooperative Highway Research Program (NCHRP) Report 350 Hardware Compliance Dates Memorandum - FHWA Safety Program Page 1 of 2 Memorandum US Department of Transportation Federal Highway Administration Subject: ACTION: National Cooperative Highway Research Program (NCHRP) Report 350

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Southwest Windpower, Inc. 1801 W. Route 66 Flagstaff, Arizona 86001 Phone: (928) 779-9463 Fax: (928) 779-1485 E-mail: info@windenergy.com Web: www.windenergy.com

More information

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

HIGH MAST CAMERA POLE ASSEMBLY GENERAL 10-3.24 HIGH MAST CAMERA POLE ASSEMBLY GENERAL The Contractor must furnish and install the following equipment for high mast camera pole assembly as described herein and as shown on the plans: 1. Camera

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER: FYPON, LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER: FYPON, LTD. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2601 Reissued 05/2018 This report is subject to renewal 05/2020. DIVISION: 06 00

More information

PACIFIC SHORING, LLC ALUMINUM SHORING PRODUCTS ALUMINUM S-PANEL SHIELDS. TABULATED DATA Effective April 01, 2014

PACIFIC SHORING, LLC ALUMINUM SHORING PRODUCTS ALUMINUM S-PANEL SHIELDS. TABULATED DATA Effective April 01, 2014 1 ALUMINUM S-PANEL SHIELDS Effective April 01, 2014 PSH 265 Roberts Avenue Santa Rosa, Ca. 95407 (707) 575-9014 Construction Engineering Resource 1837 Wright Street Santa Rosa, Ca. 95404 jmtengr2@aol.com

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American

More information

CONTRACT PROVISIONS. 1. The Contract will become effective beginning July 1, 2014 and will expire on July 1, 2015.

CONTRACT PROVISIONS. 1. The Contract will become effective beginning July 1, 2014 and will expire on July 1, 2015. CONTRACT PROVISIONS 1. The Contract will become effective beginning July 1, 2014 and will expire on July 1, 2015. 2. Guardrail repairs will be limited to Interstate and State Highways located in the Aberdeen

More information

GUARDRAIL WARRANTS FOR LOW VOLUME ROADS

GUARDRAIL WARRANTS FOR LOW VOLUME ROADS 74 GUARDRAIL WARRANTS FOR LOW VOLUME ROADS Louis B. Stephens, P.E. INTRODUCTION Low volume roads present many challenges to highway engineers and public administrators. Although, by definition, these facilities

More information

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work. SECTION 05520 METAL HANDRAILS AND RAILINGS PART 1 GENERAL 1.01 SUBMITTALS A. Properly identified manufacturer's literature, including shop and erection drawings before starting work. B. Railing Assemblies

More information

RCKW Kneewall Connectors

RCKW Kneewall Connectors This product is preferable to similar connectors because of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. The Simpson Strong-Tie RCKW rigid connectors

More information

STRESS-RIBBON BRIDGES STIFFENED BY ARCHES OR CABLES

STRESS-RIBBON BRIDGES STIFFENED BY ARCHES OR CABLES 2nd Int. PhD Symposium in Civil Engineering 1998 Budapest STRESS-RIBBON BRIDGES STIFFENED BY ARCHES OR CABLES Tomas Kulhavy Technical University of Brno, Department of Concrete and Masonry Structures Udolni