1 Aurecon New Zealand Limited Level 2, Iwikau Building 93 Cambridge Terrace Christchurch 8013 New Zealand T F E W christchurch@aurecongroup.com aurecongroup.com 15 May 2017 GW Haslwell Ltd 145 Papanui Road PO Box Christchurch 8146 Issued via to: Dean Gregory dean@gwlimited.nz Geotechnical Subdivision Completion Report Kirkwood the Conclusion This geotechnical completion report, and supporting Statement of Professional Opinion, is submitted in accordance with Clause 21 Subdivision Consent Application RMA/2016/3606. Introduction GW Halswell Limited is in the process of developing the Kirkwood The Conclusion residential subdivision at located at 150 Dunbars Road, Haslwell, in Christchurch. This development comprises 28 residential lots and associated roads and access ways. During the geotechnical investigation of the site parts of development were identified as being susceptible to a varying degree to the effects of seismically induced liquefaction. The liquefaction risk was assessed as being variable across the site. As such an engineered fill capping layer has been created across Lots 12, 13 and 25 to 25 in order to increase the seismic resilience of these lots. See attached plan for the extent and cross-section of the capping layer constructed at Kirkwood The Conclusion. The conditions of Aurecon s engagement are as per our original agreement relating to initial geotechnical investigation carried in September 2015, and are set out in our letter of engagement dated 14 August Geotechnical Investigation and Liquefaction Hazard Assessment Aurecon undertook a geotechnical site investigation across the site in September 2015 to support the subdivision application. This investigation is described in the Aurecon Report 150 Dunbars Road, Haswell, Geotechnical Subdivision Report, Revision 1 dated 22 September A liquefaction hazard assessment was carried out as part of the site assessments using the method prescribed in the Ministry of Business, Innovation, and Employment guidelines for residential development in Canterbury (MBIE Guidelines) following the Canterbury earthquake sequence. Based upon this assessment: Lots 1 to 11 and 14 to 24 The calculated liquefaction induced ground deformations were within the limits of a Technical Category 2 (TC2) classification. Lots 12, 13 and 25 to 28 Lots 12, 13 and 25 to 28 in their natural form were identified as being non-compliant with the full requirements of a TC2 classification based on an indexed liquefaction induced Project File Kirkwood the Conclusion 224 Sign Off Report - Rev1.docx 15 May 2017 Revision 1 Page 1

2 reconsolidation settlement criteria and thickness of non-liquefiable crust. This non-tc2 compliance is due to the southern end of the site having an increased thickness of potentially liquefiable silty-sandy soils in combination with perched groundwater table. The combination of the increase in theoretical reconsolidation settlement due to increased thickness of siltysandy soils and the thinner non-liquefiable crust due to elevated groundwater level resulted in non-compliance with the requirements of TC2. Liquefaction Risk Mitigation Due to the identified liquefaction risk, liquefaction hazard mitigation has been undertaken across the site as part of the development: Lots 1 to 11 and 14 to 24 No additional liquefaction risk mitigation is required for these lots other than an enhanced TC2 type of foundation system as per the requirements of the MBIE Guidelines. Lots 12, 13 and 25 to 28 In order to ensure a TC2 classification across the entire site and provide additional seismic resilience to the development shallow ground improvement works have been undertaken in Lots 12, 13 and 25 to 28. The ground improvement works have been based upon the concept of 2m re-compacted engineered fill capping layer option presented in Section 15 of the MBIE Guidelines. With this ground improvement implemented a TC2 foundation system can be used at these sites. Due to depth to groundwater at the site, the engineered fill layer has been reduced to a thickness of 1.7m. To compensate for the reduction in thickness the bottom 300mm of the fill layer has been formed with geogrid reinforced crushed concrete. This composite reinforced 1.7m thick layer is considered to have the same engineering properties of 2m of re-compacted site won fill. This engineer fill layer is capped with 0.3m of topsoil. Plans showing the location and a cross-section of this capping layer are appended to this report. This geogrid reinforced gravel capping layer has been constructed under the supervision of the project Civil Engineer s, Optimum Projects Limited, as part of the bulk earthworks process carried out as part of the subdivision development. Aurecon has visited the capping layer construction at critical stages. Technical Category Classification We have assessed the liquefaction hazard at the site using the method recently prescribed by MBIE guidelines, observed site performance during the major seismic events in the Canterbury earthquake sequence. Based upon our geotechnical site investigations, the liquefaction hazard assessments and the implementation of an engineered fill capping layer (in Lots 12, 13 and 25 to 28) we believe: Lots 1 to 28 fulfil the requirements of TC2 Classification, Lots 50 and 61 are roading and access right-of-way areas; therefore no Technical Category Classification is applicable for these lots. Foundation Recommendations A TC2 Classification effectively means that the MBIE believe that Minor to moderate land damage from liquefaction is possible in future significant earthquakes. With Lots 1 to 28 enhanced TC2 foundation are required as outlined in Section 5 of the MBIE Guidelines. In accordance with the Guidelines standard shallow lot specific shallow geotechnical investigations will be required during the Project File Kirkwood the Conclusion 224 Sign Off Report - Rev1.docx 15 May 2017 Revision 1 Page 2

3 detailed house design to assess the lot specific ground conditions and bearing capacity values. This assessment should be undertaken by the foundation designer. Limitations We have prepared this report in accordance with the brief as provided. The contents of the report are for the sole use of the Client and no responsibility or liability will be accepted to any third party. Data or opinions contained within the report may not be used in other contexts or for any other purposes without our prior review and agreement. The recommendations in this report are based on data collected at specific locations and by using suitable investigation techniques. Only a finite amount of information has been collected to meet the specific financial and technical requirements of the Client s brief and this report does not purport to completely describe all the site characteristics and properties. The nature and continuity of the ground between test locations has been inferred using experience and judgement and it must be appreciated that actual conditions could vary from the assumed model. Subsurface conditions relevant to construction works should be assessed by contractors who can make their own interpretation of the factual data provided. They should perform any additional tests as necessary for their own purposes. Subsurface conditions, such as groundwater levels, can change over time. This should be borne in mind, particularly if the report is used after a protracted delay. This report is not to be reproduced either wholly or in part without our prior written permission. This conclusions in this report draws on investigations, analysis and conclusions from various investigations stages and numerous reports. For specific details please refer to the above mentioned references or contact the writers. If you have any queries regarding the content of this letter, please do not hesitate to contact the undersigned. Yours faithfully Dr Jan Kupec Technical Director Ground Engineering Enc: Site Layout Plan and Capping Layer Detail Statement of Professional Opinion Project File Kirkwood the Conclusion 224 Sign Off Report - Rev1.docx 15 May 2017 Revision 1 Page 3

4 This drawing is subject to copyright and remains the property of optimum projects ltd at all times. It shall not be reproduced without the written consent of optimum projects ltd and is confidential in terms of the building act. S Z:\JOB FILES\ KIRKWOOD - THE CONCLUSION\DRAWINGS\2630-C.DWG 12/05/17 15:13 A1 ORIGINAL 16 S S S Lo DP 33 S Lot 1 DP S Lot 2 DP Lot 3 Area of TC3 remediation 7 Lot 4 DP S S Lot 2 boundary 300mm topsoil existing surface 27 Lot 1 S S m site won fill compacted to NZS S existing ground 0.3m pitrun / crushed concrete tensar TX-160 geogrid to be installed in strict accordance with the manufacturers specification on bidim A19 geofabric S Lot 74 typical remediation of TC3 land a1, a3 Note: 1. granular and cohesive soils are to be compacted to a minimum of 95% MDD, in addition to the requirements of NZS During excavation, silt is to be separated from the sandy material and placed at the surface of the 2m ground improvement, with the sandy material placed at the base on the geogrid. 3. Refer to geotechnical site notice for further installation requirements. 4. services installed above geogrid. Engineer to be notified prior to construction if services are to be installed through or lower than geogrid. TC3 remediation location a1, a3 4 as built kb optimum projects ltd project P O Box revised for approval kb christchurch site 2 for approval kb kb kb as shown gw halswell ltd kirkwood - the conclusion TC3 remediation area C1.2 ph: for approval 4 kb solutions issue description by appd. date drawn designed approved scales client project title drawing title drawing no issue

5 Statement of Professional Opinion on the Suitability of Land for Subdivision (Appendix I to the Infrastructure Design Standard) Issued by: Aurecon New Zealand Limited (Geotechnical engineering firm or suitably qualified engineer) To: GW Halswell Limited (Owner/Developer) To be supplied to: Christchurch City Council (Territorial authority) In respect of: Residential Subdivision (Description of proposed infrastructure/land development) At: Lot 43, DP , 1 Stallion Avenue, Halswell, Christchurch (Address) I (Geotechnical engineer) Dr Jan Kupec on behalf of (Geotechnical engineering firm) Aurecon New Zealand Limited hereby confirm: 1. I am a suitably qualified and experienced geotechnical engineer and was retained by the owner/developer as the geotechnical engineer on the above proposed development. 2. My/the geotechnical assessment report, dated 7 October 2016 and 224 Certificate geotechnical completion report 15 May 2017 has been carried out in accordance with the Department of Building and Housing Guidelines for geotechnical investigation and assessment of subdivisions and includes: (i) Details of and the results of my/the site investigations. (ii) A liquefaction assessment. (iii) An assessment of rockfall and slippage, including hazards resulting from seismic activity. (iv) An assessment of the slope stability and ground bearing capacity confirming the location and appropriateness of building sites. (v) Recommendations proposing measures to avoid, remedy or mitigate any potential hazards on the land subject to the application, in accordance with the provisions of Section 106 of the Resource Management Act In my professional opinion, I consider that Council is justified in granting consent incorporating the following conditions: The recommendations presented in the following reports are implemented: - '1 Stallion Ave, Halswell, Geotechcnail Subdivision report', Revision 2, Job No , dated 7 October 'Geotechncail Subdivision Completions Report - Kirkwood the Conclusion' Job No , dated 15 May This professional opinion is furnished to the territorial authority and the owner/developer for their purposes alone, on the express condition that it will not be relied upon by any other person and does not remove the necessity for the normal inspection of foundation conditions at the time of erection of any building. Updated: of 2 P-055

6 5. This certificate shall be read in conjunction with my/the geotechnical report referred to in Clause 2 above, and shall not be copied or reproduced except in conjunction with the full geotechnical completion report. 6. The geotechnical engineering firm issuing this statement holds a current policy of professional indemnity insurance of no less than $ 250,000 (Minimum amount of insurance shall be commensurate with the current amounts recommended by IPENZ, ACENZ, TNZ, INGENIUM.)... (Signature of Engineer) Date: 15 May 2017 Qualifications and experience: PhD, MSc, canding, MIPENZ, CPEng, IntPE Updated: of 2 P-055

STRUCTURAL CALCULATIONS & DETAILS

STRUCTURAL CALCULATIONS & DETAILS S y n g e C o n s u l t i n g Ltd. S t r u c t u r a l E n g i n e e r i n g STRUCTURAL CALCULATIONS & DETAILS Pole Retaining Wall at 61 Exploration Way Whitby Lot 100 DP 478324 Prepared for: Keys Construction

More information

Chartered Professional Engineer (Geotechnical) Body of Knowledge and Skills

Chartered Professional Engineer (Geotechnical) Body of Knowledge and Skills 18 October 2016 Chartered Professional Engineer (Geotechnical) 1. Introduction This document defines the core knowledge and skills that a Chartered Professional Engineer (Geotechnical) ((Geotechnical))

More information

Practical Implications of Increased Liquefaction Vulnerability

Practical Implications of Increased Liquefaction Vulnerability REPORT Practical Implications of Increased Liquefaction Vulnerability Prepared for Chapman Tripp acting on behalf of the Earthquake Commission (EQC) Prepared by Date Job Number 52010.140.v1.0 Distribution:

More information

Part C: Assessing, repairing and rebuilding foundations in TC3 Contents

Part C: Assessing, repairing and rebuilding foundations in TC3 Contents C 2. FOUNDATION CONTENTS Part C: Assessing, repairing and rebuilding foundations in TC3 Contents 11. Introduction to TC3 11.1 Overview... 11.1 11.2 General principles... 11.2 11.3 Scope... 11.4 11.4 Future

More information

Strength reduction factors for foundations and earthquake load combinations including overstrength factors

Strength reduction factors for foundations and earthquake load combinations including overstrength factors Strength reduction factors for foundations and earthquake load combinations including overstrength factors S.J Palmer Tonkin & Taylor Ltd, Wellington, New Zealand 2013 NZSEE Conference ABSTRACT: Clause

More information

Structural Eurocodes an overview

Structural Eurocodes an overview Structural Eurocodes an overview BS EN 1990, Eurocode Basis of Structural Design Structural safety, serviceability and durability BS EN 1991, Eurocode 1 Actions on Structures Actions on structures BS EN

More information

Whangarei District Council Forum North Private Bag 9023 Whangarei T&T job no: 17464.002 05 December 2005 Attention: Harvey Schroyen Dear Harvey Review and Usage of Mine Subsidence Hazard Zones for Kamo

More information

CHRISTCHURCH CITY COUNCIL PRK_1385_BLDG_005 EQ2 Bexley Park Underground Bunker 194 Bexley Road, Bexley

CHRISTCHURCH CITY COUNCIL PRK_1385_BLDG_005 EQ2 Bexley Park Underground Bunker 194 Bexley Road, Bexley CHRISTCHURCH CITY COUNCIL QUANTITATIVE ASSESSMENT REPORT FINAL Rev B CHRISTCHURCH CITY COUNCIL QUANTITATIVE ASSESSMENT REPORT FINAL Rev B Sinclair Knight Merz 142 Sherborne Street Saint Albans PO Box 21011,

More information

Producer Statement. Design: On-Site Effluent Disposal Systems (AS/NZS 1547:2000)

Producer Statement. Design: On-Site Effluent Disposal Systems (AS/NZS 1547:2000) Updated 04/09/13 Producer Statement Design: On-Site Effluent Disposal Systems (AS/NZS 1547:2000) Issued by : To : To be supplied to: Property Location:. (approved qualified design professional) (owner)

More information

Green Zone Technical Category 1 (TC1)

Green Zone Technical Category 1 (TC1) Green Zone Technical Category 1 (TC1) Why has it been necessary to split the green zone into different What is the difference between the Since the 4 September 2010 earthquake there has been an ongoing

More information

Earthquake-Prone Buildings Policy

Earthquake-Prone Buildings Policy Earthquake-Prone Buildings Policy Introduction and Purpose The purpose of this Policy is to balance out the need to address earthquake risk and other priorities, taking account of the social, cultural

More information

Retaining Wall Assessment and Prioritisation Paper

Retaining Wall Assessment and Prioritisation Paper Lessons learned from one of New Zealand s most challenging civil engineering projects: rebuilding the earthquake damaged pipes, roads, bridges and retaining walls in the city of Christchurch 2011-2016.

More information

Bruce Terrace Cottages Housing Complex PRO 3652 Detailed Engineering Evaluation Quantitative Assessment Report

Bruce Terrace Cottages Housing Complex PRO 3652 Detailed Engineering Evaluation Quantitative Assessment Report Christchurch City Council Bruce Terrace Cottages Housing Complex PRO 3652 Detailed Engineering Evaluation Quantitative Assessment Report Christchurch City Council Bruce Terrace Cottages Housing Complex

More information

File No Supplemental November Geotechnical and Environmental Consulting Engineers

File No Supplemental November Geotechnical and Environmental Consulting Engineers Supplemental Information & Geotechnical Recommendations Proposed New Solar Valley Location B (East of Building No. 7) Cañada Community College 4200 Farm Hill Boulevard Submitted to: Mr. Peter Hempel Construction

More information

REQUEST FOR CONSTRUCTION BIDS May 23, 2017

REQUEST FOR CONSTRUCTION BIDS May 23, 2017 REQUEST FOR CONSTRUCTION BIDS May 23, 2017 Cambridge Greenway Trail / Railroad Bridge Replacement Flood Mitigation Project 1.0 Project Background A former railroad bridge that currently carries the Cambridge

More information

MacKenzie Courts Housing Complex PRO 0921 Detailed Engineering Evaluation Quantitative Assessment Report

MacKenzie Courts Housing Complex PRO 0921 Detailed Engineering Evaluation Quantitative Assessment Report Christchurch City Council MacKenzie Courts Housing Complex PRO 0921 Detailed Engineering Evaluation Quantitative Assessment Report Christchurch City Council MacKenzie Courts Housing Complex Quantitative

More information

Soil Erosion and Sedimentation Control Compliance Form

Soil Erosion and Sedimentation Control Compliance Form Town of Southern Pines Soil Erosion and Sedimentation Control Compliance Form Tracts Less than Thirty-Thousand Square Feet (30,000 SF) Residential and Commercial This compliance form shall be prominently

More information

RIGID INCLUSIONS. Rigid Inclusions offer an economical approach for building on sites underlain by soft soil.

RIGID INCLUSIONS. Rigid Inclusions offer an economical approach for building on sites underlain by soft soil. H A Y W A R D B A K E R I N C. RIGID INCLUSIONS Rigid Inclusions offer an economical approach for building on sites underlain by soft soil. Above: HBI installed Rigid Inclusions on a congested downtown

More information

EMERGENCY MANAGEMENT ACT

EMERGENCY MANAGEMENT ACT Province of Alberta Revised Statutes of Alberta 2000 Current as of December 11, 2013 Office Consolidation Published by Alberta Queen s Printer Alberta Queen s Printer Suite 700, Park Plaza 10611-98 Avenue

More information

POLICY EARTHQUAKE PRONE DANGEROUS & INSANITARY BUILDINGS

POLICY EARTHQUAKE PRONE DANGEROUS & INSANITARY BUILDINGS POLICY EARTHQUAKE PRONE DANGEROUS & INSANITARY BUILDINGS Adopted: Council Meeting 30 June 2011 Review date: before 30 June 2016 Contents 1 Introduction and background... 1 2 Policy approach... 2 2.1 Policy

More information

Producer Statement. Design: On-Site Effluent Disposal Systems (AS/NZS 1547:2012)

Producer Statement. Design: On-Site Effluent Disposal Systems (AS/NZS 1547:2012) Producer Statement Design: On-Site Effluent Disposal Systems (AS/NZS 1547:2012) Issued by: To: To be supplied to: Property Location:. (approved qualified design professional) (owner) Kaipara District Council...

More information

LDRP 509 Knights Drain Investigation Stormwater Management Options Assessment Christchurch City Council. 12 May 2017 Revision: 2 Reference:

LDRP 509 Knights Drain Investigation Stormwater Management Options Assessment Christchurch City Council. 12 May 2017 Revision: 2 Reference: LDRP 509 Knights Drain Investigation Stormwater Management Options Assessment Christchurch City Council 12 May 2017 Revision: 2 Reference: 255287 Document control record Document prepared by: Aurecon New

More information

REQUEST FOR PROPOSAL (RFP)

REQUEST FOR PROPOSAL (RFP) ANGUILLA ELECTRICITY COMPANY LIMITED (ANGLEC) REQUEST FOR PROPOSAL (RFP) AUGUST 2017 CONSULTANCY SERVICES FOR THE DEVELOPMENT OF AN OCCUPATIONAL HEALTH AND SAFETY PROGRAM CONTENTS Page SECTION 1 : Invitation

More information

Earthquake-prone, Dangerous and Insanitary Buildings Policy 2011

Earthquake-prone, Dangerous and Insanitary Buildings Policy 2011 Earthquake-prone, Dangerous and Insanitary Buildings Policy 2011 1.0 Introduction 1.1 Objective To ensure that the policy on earthquake-prone, dangerous and insanitary buildings meets the requirements

More information

Applied GeoScience, Inc Hammond Dr., Suite 6 Schaumburg, Illinois

Applied GeoScience, Inc Hammond Dr., Suite 6 Schaumburg, Illinois AGI Project No. 13-276 Subsurface Investigation Report For the Proposed New Retail Center 9601 South Pulaski Road Evergreen Park, Illinois Prepared for Mr. Feras Sweis FHS Design + Build LLC 2010 West

More information

EARTHQUAKE PRONE BUILDINGS POLICY

EARTHQUAKE PRONE BUILDINGS POLICY EARTHQUAKE PRONE BUILDINGS POLICY 1. INTRODUCTION AND BACKGROUND 1.1 The Building Act 2004 requires territorial authorities to adopt a policy on earthquake prone buildings by 31 st May 2006. 1.2 This policy

More information

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit: TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION 355-7575 Ext. 395 Needed to Obtain Permit: 1. Building Permit Application, and/or residential plumbing permit application, as applicable, to be

More information

REQUEST FOR TENDER - SERVICES RFT HOUSE DEMOLITION 7958 BEAVERDAMS RD., NIAGARA FALLS, ON.

REQUEST FOR TENDER - SERVICES RFT HOUSE DEMOLITION 7958 BEAVERDAMS RD., NIAGARA FALLS, ON. REQUEST FOR TENDER - SERVICES 1. PURPOSE AND SCOPE This specification is intended to govern the supply of all labour, materials and equipment for the dismantling, demolition of a single dwelling on the

More information

Quick guide to product substitution

Quick guide to product substitution Quick guide to product substitution p1 of 12 Contents Use of this guide... 2 Purpose... 3 Introduction... 3 Step 1: Consider the law... 5 Step 2: Consider the building implications... 7 Step 3: Implement

More information

REPORT STATUS: DATE: Report n :

REPORT STATUS: DATE: Report n : REPORT: Expanded clay LWA in CEA Lightweight fill and thermal insulation products for civil engineering applications. Installation and structural quality control on site. STATUS: Technical report DATE:

More information

In the event of any occurrence that does or could pose a hazard to rail traffic or the public, contact Canadian Pacific Railway at

In the event of any occurrence that does or could pose a hazard to rail traffic or the public, contact Canadian Pacific Railway at Canadian Pacific Railway Technical Standards Services Guidelines for excavations on CPR property Last updated March 8, 2012 1. Introduction The purpose of this document is to assure the safety of rail

More information

Terms of Reference for Assessment of Water System Infrastructure and Water Supply Sources for Semi-Public Water Systems

Terms of Reference for Assessment of Water System Infrastructure and Water Supply Sources for Semi-Public Water Systems Manitoba Water Stewardship Terms of Reference for Assessment of Water System Infrastructure and Water Supply Sources for Semi-Public Water Systems Date: June 2007 Prepared for Office of Drinking Water

More information

ICC-ES Evaluation Report Issued July 1, 2011 This report is subject to renewal in one year.

ICC-ES Evaluation Report Issued July 1, 2011 This report is subject to renewal in one year. ICC-ES Evaluation Report ESR-1959 Issued July 1, 2011 This report is subject to renewal in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

New Zealand Transport Agency: Christchurch Southern Motorway Proposal. Notices of requirement and resource consent applications

New Zealand Transport Agency: Christchurch Southern Motorway Proposal. Notices of requirement and resource consent applications Public notice New Zealand Transport Agency: Christchurch Southern Motorway Proposal Notices of requirement and resource consent applications The New Zealand Transport Agency has lodged an application with

More information

Practice Advisory 14: Long span steel roof trusses - welding and section checks

Practice Advisory 14: Long span steel roof trusses - welding and section checks Practice Advisory 14: Long span steel roof trusses - welding and section checks This Practice Advisory was issued in response to concerns about the collapse of the Stadium Southland roof in Invercargill

More information

In preparation for constructing buildings on a property, the builder. Site Preparation CHAPTER

In preparation for constructing buildings on a property, the builder. Site Preparation CHAPTER CHAPTER 3 Site Preparation In preparation for constructing buildings on a property, the builder must consider a number of factors related to code requirements. The buildings must be located according to

More information

Subsurface Investigation Report. Proposed New 1-Story Building 6447 Grand Avenue Gurnee, Illinois

Subsurface Investigation Report. Proposed New 1-Story Building 6447 Grand Avenue Gurnee, Illinois AGI Project No. -11 Subsurface Investigation Report For the Proposed New 1-Story Building 6447 Grand Avenue Gurnee, Illinois Prepared for Mr. Steve Panko Key Development Partners, LLC North State Street,

More information

Evaluation Report. for. Empire West, Inc Graton Road Post Office Box 511 Graton, California 95444

Evaluation Report. for. Empire West, Inc Graton Road Post Office Box 511 Graton, California 95444 for Empire West, Inc. 9270 Graton Road Post Office Box 511 Graton, California 95444 CertMark International Pty Ltd (CMI) has awarded this Certification to the company named above for the Product/system

More information

VOTR Site Assessment Victoria on the River

VOTR Site Assessment Victoria on the River i Executive Summary A. Introduction AECOM New Zealand Limited (AECOM) was engaged by Hamilton City Council (HCC) to undertake a geotechnical assessment of the (VOTR) site in Hamilton s central business

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 1547:2012 AS/NZS 1547:2012 Australian/New Zealand Standard On-site domestic wastewater management AS/NZS 1547:2012 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee

More information

Environmental and Social Management Plan

Environmental and Social Management Plan Environmental and Social Management Plan Capital Works State Highway 205 / Schist Street Intersection Upgrade 21 September 2015 NZTA142200 Page ii Record of amendment Amendment number Description of change

More information

Temporary Works Forum (TWf) Chairman: Bill Hewlett MA CEng FICE Secretary: John Carpenter CEng, FICE, FIStructE, CFIOSH

Temporary Works Forum (TWf) Chairman: Bill Hewlett MA CEng FICE Secretary: John Carpenter CEng, FICE, FIStructE, CFIOSH TW/11/027 Rev F (issued: February 12). Rev G (minor changes March 12) COMPETENCIES OF THE TWC 1 1 Background It is important that those individuals appointed to the roles of Temporary Works Coordinators

More information

Technical Circular T-06/09 Date: July 30, 2009

Technical Circular T-06/09 Date: July 30, 2009 Technical Circular T-06/09 Date: July 30, 2009 To: All HQ Directors: Operations, Planning and Major Projects All Regional Directors All District Managers Transportation All Project Managers All Regional

More information

Guidance on the Application. of ISO / IEC Accreditation International Association for Certifying Bodies

Guidance on the Application. of ISO / IEC Accreditation International Association for Certifying Bodies Accreditation International Association for Certifying Bodies Guidance on the Application of ISO / IEC 17020 Guidance on the Application of ISO/IEC 17020 Page 1 of 16 Introduction This guidance document

More information

April 7, Webster Street Sub-Surface Stormwater Storage System Bid No Bid Date: 4/13/17 ADDENDUM NO 1

April 7, Webster Street Sub-Surface Stormwater Storage System Bid No Bid Date: 4/13/17 ADDENDUM NO 1 PUBLIC WORKS DEPARTMENT David A. Jones, P.E., Director April 7, 2017 Webster Street Sub-Surface Stormwater Storage System Bid No. 2017-022 Bid Date: 4/13/17 ADDENDUM NO 1 Please make the following changes

More information

Information for building owners & building practitioners: Building work that does not require a building consent. Council discretionary exemptions

Information for building owners & building practitioners: Building work that does not require a building consent. Council discretionary exemptions Information for building owners & building practitioners: Building work that does not require a building consent The Building Act has allowed for some specified work to be carried out without requiring

More information

ICCPC INTERNATIONAL CODE COUNCIL PERFORMANCE CODE FOR BUILDINGS AND FACILITIES

ICCPC INTERNATIONAL CODE COUNCIL PERFORMANCE CODE FOR BUILDINGS AND FACILITIES A MEMBER OF THE INTERNATIONAL CODE FAMILY ICCPC INTERNATIONAL CODE COUNCIL PERFORMANCE CODE FOR BUILDINGS AND FACILITIES Receive FREE updates, excerpts of code references, technical articles, and more

More information

CF50/100 KW TURBINE ACCESS ROAD, CRANE PLATFORM, CONCRETE, AND LIFTING SPECIFICATIONS C&F GREEN ENERGY REVISION PREPARED BY APPROVED BY DATE

CF50/100 KW TURBINE ACCESS ROAD, CRANE PLATFORM, CONCRETE, AND LIFTING SPECIFICATIONS C&F GREEN ENERGY REVISION PREPARED BY APPROVED BY DATE CF50/100 KW TURBINE ACCESS ROAD, CRANE PLATFORM, CONCRETE, AND LIFTING SPECIFICATIONS C&F GREEN ENERGY REVISION PREPARED BY APPROVED BY DATE 001 First Draft W Hession 12.02.2014 Introduction This document

More information

Tensar Technology for use in the Oil and Gas Industry

Tensar Technology for use in the Oil and Gas Industry Tensar Technology for use in the Oil and Gas Industry Large pipe section being transported along a road reinforced with Tensar geogrid in Kirishi, Russia. Tensar Technology - proven, practical products

More information

Cuthberts Green Toilet/Pavilion PRK 0893 BLDG 008 EQ2 Detailed Engineering Evaluation Quantitative Report Version FINAL. 220 Pages Road, Wainoni

Cuthberts Green Toilet/Pavilion PRK 0893 BLDG 008 EQ2 Detailed Engineering Evaluation Quantitative Report Version FINAL. 220 Pages Road, Wainoni Cuthberts Green Toilet/Pavilion PRK 0893 BLDG 008 EQ2 Quantitative Report Version FINAL 220 Pages Road, Wainoni Cuthberts Green Toilet/Pavilion PRK 0893 BLDG 008 EQ2 Quantitative Report Version FINAL 220

More information

Hazardous. Scheme. the power behind your business

Hazardous. Scheme. the power behind your business Hazardous Areas Scheme YOUR GUIDE TO REGISTRATION the power behind your business GUIDE TO REGISTRATION REQUIREMENTS Electrical work in potentially explosive atmospheres (hazardous areas) is not included

More information

Appendix 1. Schedules 5, 6, 7 and 8

Appendix 1. Schedules 5, 6, 7 and 8 Appendix 1 Schedules 5, 6, 7 and 8 Schedule 5 - On-site Wastewater Disposal Site and Soil Evaluation Checklist To be completed by a person accredited in site and soil assessment for on-site wastewater

More information

Campbell River Environmental Committee 2353 Dolly Varden Road Campbell River, BC V9W 4W5 (Via ) Attention: Leona Adams

Campbell River Environmental Committee 2353 Dolly Varden Road Campbell River, BC V9W 4W5 (Via  ) Attention: Leona Adams October 17, 2016 16-27 Campbell River Environmental Committee 2353 Dolly Varden Road Campbell River, BC V9W 4W5 (Via email) Attention: Leona Adams Re: Review of Upland Excavating Landfill Application Technical

More information

SPECIFICATION FOR ENGINEERED FILLS

SPECIFICATION FOR ENGINEERED FILLS SPECIFICATION FOR ENGINEERED FILLS This specification is intended to be used for the engineered fill. The specification is suitable for most purposes but there may be special conditions existing at some

More information

PRE-QUALIFICATION FOR PROVISION OF TEAM BUILDING CONSULTANCY SERVICES TENDER NO. KPPF /HRA-B/1-A/22/17-18

PRE-QUALIFICATION FOR PROVISION OF TEAM BUILDING CONSULTANCY SERVICES TENDER NO. KPPF /HRA-B/1-A/22/17-18 PRE-QUALIFICATION FOR PROVISION OF TEAM BUILDING CONSULTANCY SERVICES TENDER NO. KPPF /HRA-B/1-A/22/17-18 (JAN 2017 DEC 2018) PRE QUALIFICATION DOCUMENT Stima Plaza, Kolobot Road, P.O. Box 1548-00600 Nairobi,

More information

DESIGN OF PILE FOUNDATIONS IN LIQUEFIABLE SOILS

DESIGN OF PILE FOUNDATIONS IN LIQUEFIABLE SOILS DESIGN OF PILE FOUNDATIONS IN LIQUEFIABLE SOILS This page intentionally left blank DESIGN OF PILE FOUNDATIONS IN LIQUEFIABLE SOILS Gopal Madabhushi University of Cambridge, UK Jonathan Knappett University

More information

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular

More information

This report presents the findings of the subsurface exploration concerning the design of the taxiway rehabilitation. Description

This report presents the findings of the subsurface exploration concerning the design of the taxiway rehabilitation. Description September 22, 2016 American Infrastructure Development, Inc. 3810 Northdale Boulevard, Suite 170 Tampa, Florida 33624 Attn: Mr. Mohsen Mohammadi, Ph.D., P.E. Senior Consultant Mob: (813) 244-6609 E-mail:

More information

Subsurface Investigation Report

Subsurface Investigation Report AGI Project No. 17-154 Subsurface Investigation Report For the Proposed New One-Story Building Addition 7030 West 111 th Street Worth, Illinois Prepared for T63 Development LLC 11052 Mayflow er Lane Orland

More information

SepticDesign.ca Gunnell Engineering Ltd.

SepticDesign.ca Gunnell Engineering Ltd. SepticDesign.ca Gunnell Engineering Ltd. Presentation Summary Best Practices Code Context Prior to Attending the Site When on Site Site Assessment Assessing Existing Sewage Systems The Septic Test Pit

More information

SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE

SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE BE IT ORDAINED by the Town Council of the Town of Plainville: SECTION 1. SUBDIVISIONS. All subdivisions hereinafter developed within

More information

FLOOD PLAIN STANDARDS AND REQUIREMENTS. Adopted by City Council on September 16, 2014 Effective January 1, 2015

FLOOD PLAIN STANDARDS AND REQUIREMENTS. Adopted by City Council on September 16, 2014 Effective January 1, 2015 City of Vancouver Land Use and Development Policies and Guidelines Planning and Development Services, 453 W. 12th Ave Vancouver, BC V5Y 1V4 tel 604.873.7000 fax 604.873.7060 planning@vancouver.ca FLOOD

More information

GUIDANCE. Securing parapets and facades on unreinforced masonry buildings. Advice for building owners, councils and engineers

GUIDANCE. Securing parapets and facades on unreinforced masonry buildings. Advice for building owners, councils and engineers GUIDANCE Securing parapets and facades on unreinforced masonry buildings Advice for building owners, councils and engineers OCTOBER 2017 1. INTRODUCTION DOCUMENT STATUS Ministry of Business, Innovation

More information

LAYING IBSTOCK CLAY PAVERS FOR PERMEABLE PAVEMENTS

LAYING IBSTOCK CLAY PAVERS FOR PERMEABLE PAVEMENTS PERMEABLE PAVEMENTS (SUDS) This leaflet highlights the basic requirements for laying Ibstock clay pavers to form a permeable pavement. Ibstock clay pavers are intended for domestic use only i.e. patios

More information

REVISED NEW HANOVER COUNTY OGDEN SKATEPARK SPECIALTY PRE-QUALIFICATION PACKET

REVISED NEW HANOVER COUNTY OGDEN SKATEPARK SPECIALTY PRE-QUALIFICATION PACKET REVISED NEW HANOVER COUNTY OGDEN SKATEPARK SPECIALTY PRE-QUALIFICATION PACKET This project is being readvertised due to the small number of prequalification packages received in response to the county's

More information

PRACTICE NOTES FOR QUANTITY SURVEYORS

PRACTICE NOTES FOR QUANTITY SURVEYORS PRACTICE NOTES FOR QUANTITY SURVEYORS Preface Preface A Working Committee with representatives of the Hong Kong Institute of Surveyors, the Association of Consultant Quantity Surveyors and the Hong Kong

More information

Quality Assurance Manual

Quality Assurance Manual Quality Assurance Manual Current Electrical is committed to leading the market in satisfying customer needs by providing versatile and innovative electrical and control solutions We take pride in the ability

More information

Environmental Information Form

Environmental Information Form CITY OF MODESTO Community and Economic Development Department/Planning Division 1010 Tenth Street, Suite 3300, P.O. Box 642 Modesto, CA 95353 (209) 577-5267 (209) 491-5798 FAX This questionnaire will assist

More information

Improving resource consent conditions

Improving resource consent conditions Improving resource consent conditions Mike Freeman, Director, Freeman Environmental Ltd. Introduction The management of New Zealand s water, stormwater and wastewater infrastructure is critical to our

More information

2016 Port of San Francisco Building Code

2016 Port of San Francisco Building Code PORT CODE PROCEDURE NO. : DATE : December 5, 2012 SUBJECT : Permit Process; Inspection TITLE : Special Inspection and Structural Observation Procedures PURPOSE : The purpose of this Port Code Procedure

More information

Review of agreed-upon procedures engagements questionnaire

Review of agreed-upon procedures engagements questionnaire Review of agreed-upon procedures engagements questionnaire Review code Reviewer Review date Introduction Standards on Related Services (ASRSs) detail the responsibilities of an assurance practitioner,

More information

b~êíüèì~âé=éêçåé= ÄìáäÇáåÖ=éçäáÅó=

b~êíüèì~âé=éêçåé= ÄìáäÇáåÖ=éçäáÅó= b~êíüèì~âé=éêçåé= ÄìáäÇáåÖ=éçäáÅó= adopted 2007 1. Introduction and Background Section 131 of The Building Act 2004 requires territorial authorities (TAs) to adopt a policy on earthquake-prone buildings.

More information

The Afton TSF, situated approximately 12 km west of Kamloops, BC has been under care and maintenance since 1997.

The Afton TSF, situated approximately 12 km west of Kamloops, BC has been under care and maintenance since 1997. November 27, 2014 KGHM Ajax Mining Inc. Ajax Project Suite 200-124 Seymour Street Kamloops, BC V2C 2E1 ISSUED FOR USE FILE: V15103098-01 via Email: kate.parsons@kghm.com Attention: Subject: Kate Parsons,

More information

VERTI-BLOCK - DESIGN MANUAL

VERTI-BLOCK - DESIGN MANUAL Company Information General Information Verti-Block is the latest innovative forming system from Verti-Crete, LLC. Recognized worldwide for outstanding aesthetics and performance, Verti-Crete s proprietary

More information

DISCUSSION ON UNDERPINNING (28/3/12)

DISCUSSION ON UNDERPINNING (28/3/12) DISCUSSION ON UNDERPINNING (28/3/12) The following are opinions of the writer related to various forms of underpinning and foundation stabilization. It should be noted that every situation requires an

More information

CITY OF THREE RIVERS, MICHIGAN Specifications for Bids. Tree and/or Stump Removal Performance Bids

CITY OF THREE RIVERS, MICHIGAN Specifications for Bids. Tree and/or Stump Removal Performance Bids CITY OF THREE RIVERS, MICHIGAN Specifications for Bids Tree and/or Stump Removal Performance Bids The City of Three Rivers is committed to the concept of performance bids. All vendors are encouraged to

More information

Determination regarding heart macrocarpa posts and decking to a house at 51 Wastney Terrace, Nelson

Determination regarding heart macrocarpa posts and decking to a house at 51 Wastney Terrace, Nelson Determination 2007/135 Determination regarding heart macrocarpa posts and decking to a house at 51 Wastney Terrace, Nelson 1. The matter to be determined 1.1 This is a determination under Part 3 Subpart

More information

... FOR IN-HOUSE LAWYERS. Law Society of New South Wales In-House Lawyers Committee Handy hints for in-house lawyers 1

... FOR IN-HOUSE LAWYERS. Law Society of New South Wales In-House Lawyers Committee Handy hints for in-house lawyers 1 ... FOR IN-HOUSE LAWYERS Law Society of New South Wales In-House Lawyers Committee 1 AIM In-house lawyers are subject to the same ethical rules as private practitioners. However, in-house lawyers face

More information

Rock Fill Layer Management and Maintenance Plan Former BNSF Site 13 Highway 99 Eugene, Oregon

Rock Fill Layer Management and Maintenance Plan Former BNSF Site 13 Highway 99 Eugene, Oregon Rock Fill Layer Management and Maintenance Plan 13 Highway 99 Prepared for: Half Moon LLC P.O. Box 25112 97402 PBS Project No. 51833.000 Rock Fill Layer Management and Maintenance Plan TABLE OF CONTENTS

More information

POST-EARTHQUAKE BUILDING MANAGEMENT RECOVERY PHASE

POST-EARTHQUAKE BUILDING MANAGEMENT RECOVERY PHASE POST-EARTHQUAKE BUILDING MANAGEMENT RECOVERY PHASE H.J. Hare 1, D.R. Brunsdon 2, M.C. Stannard 3, R.D. Jury 4, G.J. Beattie 5, N.J. Traylen 6, K.J. McManus 7, D.K. Bull 8 ABSTRACT The Canterbury earthquake

More information

Practice Advisory 14. Long span steel roof trusses: welding and section checks needed for some

Practice Advisory 14. Long span steel roof trusses: welding and section checks needed for some Practice Advisory 14 Long span steel roof trusses: welding and section checks needed for some This Practice Advisory is issued in response to concerns about the collapse on 18 September 2010 of the Stadium

More information

Regulations of the People s Republic of China on the Emergency. Prevention and Handling of Marine Pollution Caused by Ships

Regulations of the People s Republic of China on the Emergency. Prevention and Handling of Marine Pollution Caused by Ships Regulations of the People s Republic of China on the Emergency Prevention and Handling of Marine Pollution Caused by Ships Chapter One General Principles Article 1 In order to improve the emergency handling

More information

United Nations Development Programme (UNDP) FOR THE

United Nations Development Programme (UNDP) FOR THE United Nations Development Programme (UNDP) CALL FOR EXPRESSIONS OF INTEREST AND PREQUALIFICATION FOR THE CONSTRUCTION AND REHABILITATION OF IRRIGATION SYSTEMS IN LEBANON UNDP Lebanon invites interested

More information

MASTERTON DISTRICT COUNCIL EARTHQUAKE PRONE BUILDINGS POLICY

MASTERTON DISTRICT COUNCIL EARTHQUAKE PRONE BUILDINGS POLICY MASTERTON DISTRICT COUNCIL EARTHQUAKE PRONE BUILDINGS POLICY 2006 1. INTRODUCTION AND BACKGROUND 2 1.1 The Building Act 2004 requires territorial authorities to adopt a policy on earthquake prone buildings

More information

LANDSCAPE RETAINING WALLS

LANDSCAPE RETAINING WALLS SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9070 - Landscape Retaining Walls LANDSCAPE RETAINING WALLS PART - GENERAL.0 SECTION INCLUDES A. Modular Block Retaining Walls

More information

Scope of Work Bid Package C-4 - West Polished Concrete

Scope of Work Bid Package C-4 - West Polished Concrete Scope of Work Bid Package C-4 - West Polished Concrete CONTRACT DOCUMENTS and REQUIREMENTS The Work of this Agreement shall include but shall not be limited to all labor, fringe benefits, materials, tools,

More information

GEOTECHNICAL RESISTANCE FACTORS

GEOTECHNICAL RESISTANCE FACTORS Chapter 9 GEOTECHNICAL RESISTANCE FACTORS Final SCDOT GEOTECHNICAL DESIGN MANUAL 9-i Table of Contents Section Page 9.1 Introduction... 9-1 9.2 Soil Properties... 9-2 9.3 Resistance Factors for LRFD Geotechnical

More information

REPORT FORM. TERMINATION OF EMPLOYMENT CONVENTION, 1982 (No. 158)

REPORT FORM. TERMINATION OF EMPLOYMENT CONVENTION, 1982 (No. 158) Appl. 22.158 158. Termination of Employment, 1982 INTERNATIONAL LABOUR OFFICE GENEVA REPORT FORM FOR THE TERMINATION OF EMPLOYMENT CONVENTION, 1982 (No. 158) The present report form is for the use of countries

More information

Foundation/Site Work Code Requirements

Foundation/Site Work Code Requirements Q: What is a Foundation Only permit and why did I receive one when I filed for a full Building Permit? All Building Permits for new construction and additions are reviewed for zoning compliance. This review

More information

This qualification is expiring. The last date to meet the requirements is 31 December 2010.

This qualification is expiring. The last date to meet the requirements is 31 December 2010. NQF Ref 0209 Version 5 Page 1 of 11 National Certificate in Civil Construction Supervision with optional strands in Demolition; Drainage; Earthworks; Survey and Set Out; High Capacity Highways; Road Construction;

More information

Special Inspections Instructions

Special Inspections Instructions Special Inspections Instructions Based on Chapter 17 of the 2012 International Building Code PURPOSE The purpose of this document is to familiarize the Owner, Engineer, Architect, Special Inspector, Testing

More information

Avon Lake Municipal Landfill, Lorain County Ohio Administrative Code (OAC) Rule Authorization

Avon Lake Municipal Landfill, Lorain County Ohio Administrative Code (OAC) Rule Authorization State of Ohio Environmental Protection Agency STREET ADDRESS: MAILING ADDRESS: Lazarus Government Center TELE: (614) 644-3020 FAX: (614) 644-3184 P.O. Box 1049 122 S. Front Street www.epa.state.oh.us Columbus,

More information

Odoo Partnership Agreement

Odoo Partnership Agreement Note: Version 6a - 2017-12-11 BETWEEN: Odoo S.A., registered at the Trade and Companies Register of Nivelles under number RCN 95656, having its registered office at Chaussée de Namur, 40, 1367 Grand-Rosière,

More information

EARTHQUAKE- PRONE BUILDINGS POLICY

EARTHQUAKE- PRONE BUILDINGS POLICY EARTHQUAKE- PRONE BUILDINGS POLICY 2009 1. Introduction CONTENTS 2. Policy Objectives and Principles 3. Key Policy Components - Assessing earthquake-prone buildings - Standard of strengthening required

More information

November 12, The Law of Islamic Republic of Afghanistan Draft Law on Industrial Designs

November 12, The Law of Islamic Republic of Afghanistan Draft Law on Industrial Designs November 12, 2012 The Law of Islamic Republic of Afghanistan Draft Law on Industrial Designs Industrial Designs Chapter One General Provisions Article NO Topic Page Article 1: Basis ------------------------------------------------------------------

More information

Project Address: Name of Person Completing Form:

Project Address: Name of Person Completing Form: Statement of Inspections This form is provided as a way to list aspects of the project that require special inspection and testing in accordance with IBC Sections 107.1, 1704, and 1705 and define duties

More information

Practice Note 8 Engineers and Ethical Obligations

Practice Note 8 Engineers and Ethical Obligations www.ipenz.nz Practice Note 8 Engineers and Ethical Obligations Engineering Practice ISSN 1176-0907 Version 2, October 2016 Preface The purpose of the Practice Note Engineers and Ethical Obligations is

More information

Permit Requirements: Building Codes: The City of Clanton has adopted the following codes which are enforced by the Building Department:

Permit Requirements: Building Codes: The City of Clanton has adopted the following codes which are enforced by the Building Department: Permit Requirements: Any owner, authorized agent, or contractor who desires to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install,

More information

Queenstown Lakes District Council Contract No. C Gorge Road Rehabilitation 2015/16 Tender Documents

Queenstown Lakes District Council Contract No. C Gorge Road Rehabilitation 2015/16 Tender Documents Instructions for Tendering Contract Cover Sheet Queenstown Lakes District Council Contract No. C-16-020 Gorge Road Rehabilitation 2015/16 Tender Documents Status: For Tender Page IFT i Date: 26 th January

More information