1 North West Facilities Ltd Gaerwen Industrial Gaerwen Isle of Anglesey LL60-6HR Tel: Fax: Mobile: Project/Contract CCG Contractor Apollo Property Services Group Site Address Various sites across Gwynedd Project Start Date 14 th November 2011 Expected Duration As per Apollo s program Projected Completion Date As per Apollo s program Document Author Authorised by Authorised by Authorised by (for Client) Name Title Signature Date David Hartley Director 14/11/11 Harriette S Hartley General Manager 14/11/11 Stephen Brazier Site Manager 14/11/11 Emergency Contact Details Contact Tel Mobile Harriette S Hartley Data Protection Statement The information and data provided herein shall not be duplicated, disclosed or disseminated by the recipient in whole or in part for any purpose whatsoever without the prior written permission from North Wales Facilities Ltd, or North West Facilities Ltd. Revision Number DC/04 Revision Date 30 TH October 2011 Page 1 of 7
2 Staff Information Sheet The following method statement has been developed to provide a safe system of work and must be adhered to at all times, any significant deviation from this system must first be authorised by your manager or safety representative. Please read the entire sheet before beginning the procedure, if you have any questions please contact your manager or safety representative. The main hazards to your safety and health are; a) Falling from height b) Injury from incorrect Manual handling. c) Injury from slips trips and falls. d) Contact dermatitis from exposure to wet concrete and dust. e) Disease from standing/stagnant water. f) Injury from the incorrect actions of other contractors on site. g) Injury to members of the public during operations. h) Injury from machine hazards Preventative Measures you must take; a) You must be competent to carry out the task. b) You must NOT carry out this task alone c) Barriers erected at entrances and around the work area if deemed necessary by the foreman or safety officer to protect tenants. d) You must not lift beyond your capabilities, get help if necessary. e) Visitors and other members of staff are prohibited from entry unless accompanied by competent person, all visitors issued with personal protective equipment f) You must read and be familiar with the Safety Data Sheets for concrete which contains first aid, fire fighting, and accidental release measures. Personal Protective Equipment you must wear; a) Safety Glasses b) Dust mask c) Overalls d) Gloves e) Safety boots Revision Number DC/04 Revision Date 30 TH October 2011 Page 2 of 7
3 Environmental Protection Measures you must take; a) You must dispose of waste and spoil to the designated area or skip provided for waste. Quality Control; a) Adhere strictly to the following procedure to ensure quality of service b) If in doubt contact your manager for clarification before proceeding. Task Description 1 This method statement describes the work process for the removal of existing guttering, facia, soffit board and barge board, the inspection and making good of any damaged areas found during dismantling, and the replacement of same in new materials. 2 This Method statement describes the work process for the installation of new kitchens and Bathrooms and the refurbishment and flooring preparation, installation of new skirting boards In the kitchens and bathrooms, It also deals with any minor joinery fixes and installations of new, doors and casings, removal and replacement of rotten timber floor and ceiling joists, and the inspection and making good of any damaged areas found during dismantling, and the replacement of same in new materials. Staff & Training The projects will be carried out by staff from NWF. All members of staff are experienced and hold the following qualifications; List Qualifications. A site manager will be appointed to each contract who will be responsible for quality and safety. Apprentices and young workers will be supervised and are not allowed to carry out tasks for which they have not been trained Revision Number DC/04 Revision Date 30 TH October 2011 Page 3 of 7
4 PPE All site workers will wear Safety boots Hi Visibility Vests, Hard Hats, If required and protective clothing at all times, other items of PPE such as eye protection, and gloves are available to be worn as and when necessary. Preparation & Induction A risk assessment will be carried out for all tasks which will be discussed with members of staff and the sub contractors, any queries or concerns will be raised with the contract manager who will ensure it is dealt with. Staff and sub contractors will be inducted onto site by the principle contractor and will follow all site rules and safety procedures. Welfare The principle contractor is responsible for providing adequate washing, toilet, drying and refreshment facilities for NWF staff and sub-contractors, Apollo Property Services Group staff and contractors are responsible for ensuring that such welfare facilities are maintained in a clean and wholesome manner. First Aid It is the responsibility of all sub contractors to ensure adequate first aid provision for its staff. Adequate means provision of a trained first aider, suitable first aid equipment and/or the provision of an appointed person at the minimum. A trained first aider will be a suitable person who has attended an HSE approved course of at least four days' duration and he/she will re-train at least every three years on a course of not less than two days. An Appointed Person is a person provided by the employer to take charge of the situation (e.g. to call an ambulance) if a serious injury/illness occurs in the absence of a first aider. The Appointed Person can render emergency first aid if trained to do so. Often principle contractors will ensure sufficient first aid cover for sites under their control Revision Number DC/04 Revision Date 30 TH October 2011 Page 4 of 7
5 Background and preparation Inductions PPE required Permits to work Machinery shutdown and lock off procedures Site Access and Egress Material Handling Manual Handling Scaffold & Access to height Welfare and first aid Work at Height Working from ladders and steps Safety of other contractors and members of the public Step by step procedure FLOOR JOISTS 1. Measure up number & lengths of floor joist required 2. Collect lengths of wood from storage area and take to cutting area 3. Check joists for straightness, do not use bowed joists 4. Cut joists to required lengths 5. Fit joist hangers in position as per contract drawings (if to be used) 6. Level joists using spirit level or theodolite 7. Lay temporary platform for use as work area or lay weather protective safedeck boards as per drawings 8. Lift the first floor joists into position using the telescopic handler if available, if Not ensure good manual handling techniques are observed 9. Level joists using spirit level or theodolite 10. Lay first floor temporary platform for use as work area or lay weather protective safedeck boards as per drawings ROOF TRUSSES Revision Number DC/04 Revision Date 30 TH October 2011 Page 5 of 7
6 1. Bolt timber 100x100 timber wall plate to inside of party parapet wall as per architect drawings using m12 Rawl-bolts at 600mm ctrs 2. Lift roof trusses up the outside of the scaffolding using a crane of telehoist and place in the centre of the wall plates, manually distribute to the point of use 3. Fix roof trusses to 100x100 timber wall plate using supplied cleats by screwing into timber 4. Work from centre of roof to both gable ends ensuring trusses are level and at correct centres 5. Fit storm bracings and cross ties to roof trusses 6. Measure and cut the barge boards and fix to the end truss with proprietary fixings 7. Measure and cut the facia boards & fix to the rafter feet with proprietary fixings 8. Measure and Cut the Soffits to size and fix STAIRCASE 1. Ensure staircase in position ready for fitting 2. Cut bottoms of strings square to sit on floor 3. Cut top strings over trimmer joists to hold stairs in position 4. Fix though strings into the wall to secure stairs using supplied fixing screws 5. Fix under third tread from bottom using small stud frame to give support 6. Check stairs for strength and fully test before handover WINDOW / EXTERIOR DOOR FRAMES 1. Ensure damp proof membrane is in position 2. Test fit the frame and shave down if necessary 3. Fit the frame, test for level sill 4. Temporary wedge the frame in place in preparation for fixing and check for plumb 5. Drill the fixing holes and screw fix with raw plugs or frame fixings 6. Cut the interior sill to size and fix with propriety fixings Revision Number DC/04 Revision Date 30 TH October 2011 Page 6 of 7
7 STUD WALLS 1. Mark out the position of the internal walls as per the site plan 2. Measure and cut the Ceiling Plate 3. Nail fix the Ceiling Plate through into the joists 4. Measure and cut the Sole Plate 5. Nail fix the Sole Plate ensuring they are plumb with the Ceiling Plate 6. Mark out the position of the Studs on both the Ceiling Plate & Sole Plate 7. Measure each stud and mark up in case of any variation 8. Skew nail each stud both top and bottom and check for vertical with the spirit level 9. Mark out the position for the horizontal noggins as per site plan 10. Nail fix the horizontal noggins 11. Measure and cut to size the interior door frames 12. Nail to stud frame ensuring frame is square and plumb 13. Ensure area is left safe at end of each shift 14. Remove all waste and dispose of as per local authority guidelines Kitchen Install 1. Mark out all position fixes as per site drawings 2. Measure and cut TBC Revision Number DC/04 Revision Date 30 TH October 2011 Page 7 of 7
North West Facilities Ltd
Project/Contract North West Facilities Ltd 17-18 Gaerwen Industrial Estate Gaerwen Isle of Anglesey LL60-6HR Tel: 01248-422555 Fax: 01248-422556 Mobile: 07891 557 581 Full bathroom refit Principle Contractor
More informationMETHOD STATEMENT SCREEDING OF FLOOR
17-18 Gaerwen Industrial Estate Gaerwen Isle of Anglesey LL60-6HR Tel: 01248-422555 Fax: 01248-422556 Mobile: 07891-557581 Project/Contract Preparation of sub floors & screeding principal Contractor Apollo
More informationNorth West Facilities Ltd
North West Facilities Ltd 17-18 Gaerwen Industrial Tel: 01248-422555 Fax: 01248-422556 Mobile: 07891-557581 Project/Contract Re-decorating of kitchens, bathrooms and other rooms in residential properties
More informationACT Scaffolding Services LTD METHOD STATEMENT Scaffold erection
Address: 20 Bole Close, Wombwell, Barnsley, South Yorkshire. S73 8AZ Tel: 07883 780704 Email: enquiries@actscaffold.co.uk Web: www.actscaffold.co.uk Project/Contract Boiler Scaffolding Client Example Comp
More informationBROCHURE # 108 CONSTRUCTION PLAN COMPONENTS
BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS Please note: This construction plan component list is to be used as a guide to assist you with your project. There may be elements unique to your project not
More informationRisk Assessment & Safe Working Practice
RA Ref Number: 01f Revision: 2 Project/Job Number Reference Insert Job Number Approval Date: 30/03/2018 RA Description: Working at Heights Fixed Tubular Scaffolds Next Review Date: 01/04/2019 Notes: Please
More informationK.Construction Scotland LTD
K.Construction Scotland LTD Leith, Edinburgh, EH6 5NA, Scotland, U.K Tel: 0131-554-0514 Email: contact@kconstructionltd.com Company Number: SC288209 VAT number: GB870618611, Method Statement For the Refurbishment
More informationSECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.
SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied
More informationMMM MASONRY, INC. Employee Safety Guidelines
MMM MASONRY, INC. Employee Safety Guidelines This manual represents common hazards associated with masonry construction and is no way intended to replace the OSHA 29CFR 1926 Safety Standards. It is the
More informationSafe Work Method Statement Perimeter and Balcony Fallguard (0003)
Safe Work Method Statement Perimeter and Balcony Fallguard (0003) To be used in conjunction with SWMS 0001 General Site Activities and Fallguard Installation Manual. JOB DETAILS Principal Contractor Project
More informationThermaSteel Corporation ASSEMBLY MANUAL
ThermaSteel Corporation ASSEMBLY MANUAL TABLE OF CONTENTS 1- INTRODUCTION 1.1 THERMASTEEL TM WALL PANELS 1.2 Drawing and Element Numbers 2- ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation of Foundation
More informationSUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:
IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:
More informationSafe Work Method Statement
Company Name: Safe Work Method Statement Site Address: Other Details: Contractor: Activity/Trade: Bricklayer Date: TASKS List the tasks required to perform the activity in sequence carried out. Entry to
More informationExample Only. Outline Health and Safety Plan. Introduction. Project Brief. Appointments. Introduction. Description of Project. Location.
Outline Health and Safety Plan Introduction Introduction This Health & Safety Plan is prepared in accordance with the Construction (Design & Management) Regulations 2007, Approved Code of Practice to the
More informationHANDING-OVER CERTIFICATE - SCAFFOLDING
HANDING-OVER CERTIFICATE - SCAFFOLDING Contractor : Site : Contractor. customername Site. Site name Date : Time : Erected by : Signature : Description of section handed over Job specification. description
More informationLUXURY LOG CABINS. Built under caravan regulations act 1960, 1968 Amendment 2006 BS VAT Zero rated 701/20
CARPENTRY & CONSTRUCTION LUXURY LOG CABINS Built under caravan regulations act 1960, 1968 Amendment 2006 BS 3632-2005 VAT Zero rated 701/20 Building Regulation 2010 Intro All the cabins built by PG Carpentry
More informationPREMIER V Bucko Cast In Place
PREMIER V Bucko Cast In Place 28972 R. Ave Adel, Iowa 50003 800-343-9370 1850 West Adriatic Place Englewood, Colorado 80110 303-935-4679 Visit Monarch Materials Group, Inc. at www.monmatgrp.com Premier
More informationFrameSAFE Site-Specific Fall Protection Plan Template. Instructions for Use DO NOT INCLUDE THIS PAGE IN YOUR MANUAL SAMPLE
FrameSAFE Site-Specific Fall Protection Plan Template Instructions for Use DO NOT INCLUDE THIS PAGE IN YOUR MANUAL Step 1: Complete Site-Specific Form Enter the site-specific information in the form on
More informationCarpentry/Carpenter CIP Task Grid
Secondary Task List 100 SAFETY/OCCUPATIONAL ORIENTATION 101 Identify and follow all basic safety practices and procedures. 102 Identify and follow all lab safety practices and procedures. 103 Identify
More informationSECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.
SECTION 06 1100 WOOD FRAMING PART 1 - GENERAL 1.1 SUMMARY A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But
More informationHealth Safety, & Environment
GROUP SAFETY HEALTH AND ENVIRONMENT MANUAL R.G. Carter Construction Ltd Integrated Management System Section 7 Health Safety, & Environment Issue Manual No. Holders Name: Issue Date: GROUP HEALTH AND SAFETY
More informationCARPENTRY WORKPLACE TASKS - CHECK LIST (Note: for employer reference only)
CARPENTRY WORKPLACE TASKS - CHECK LIST (Note: for employer reference only) CPCCOHS2001A OHS requirements in the construction industry This Unit of competency specifies the outcomes required to carry out
More informationAPPLICATION FOR FINISHED BASEMENT PERMIT
APPLICATION FOR FINISHED BASEMENT PERMIT REAL ESTATE TAX I.D. #: - - _ - _ 7607 W College Drive Ph: (708) 361-1804 Fax: (708) 923-7112 building@palosheights.org APPLICANTS: COMPLETE ALL ITEMS AND SUBMIT
More informationVoid Platform Inspection Handbook V1.1
Void Platform Inspection Handbook V1.1 Void Platform Inspection Handbook - Version 1.1 1 BUILDSAFE Introduction 3 Inspection Checklist 4 Inspection Checklist 5 Signage 6 Fixing Detail 7 Fixing Detail 8
More informationLonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)
Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed
More informationSAFE WORK METHOD STATEMENT
SAFE WORK METHOD STATEMENT Company Name: THE GROUP PTY LTD This SWMS has been developed and: (T/A ARTHUR S CONCRETE CUTTING) Approved by: ATHANASIOS Address: 18 PANANIA AVE PANANIA NSW 2213 Position: TEL:
More informationHEALTH AND SAFETY CONTRACT BETWEEN EMPLOYER AND MANDATORY (CONTRACTOR) SECTION 37(2) OF THE OHS ACT, ACT 85 OF 1993
P a g e 1 SUBJECT ISSUED BY APPROVED BY CONTRACT CONTRACT BETWEEN EMPLOYER AND MANDATORY SAFETY MANAGER: SUN CITY RESORT DIRECTOR OF OPERATIONS PAGE 1 OF 15 EFFECTIVE: REVISION NO: 1 HEALTH AND SAFETY
More informationSafety Documents > Safety Manual > Scaffolds
Safety Documents > Safety Manual > Scaffolds D. Scaffolds 1. General Requirements for All Scaffolds a. Scaffolds shall be furnished and erected in accordance with this standard for persons engaged in work
More informationIncremental Change 2015
Incremental Change 2015 QCF14Av3 - Producing setting out details for routine architectural joinery products in the workplace QCF15Av3 - Marking out from setting out details for routine architectural joinery
More informationInteriors Sources Decor LLC. Method Statement BLOCK WORK. Civil Works 6/26/2016
Method Statement BLOCK WORK Civil Works 6/26/2016 The purpose of this Work Method Statement for Block Works (Concrete Masonry Units) is to outline and describe in detail the procedure such as setting and
More informationResidential fall protection. Presented by Minnesota OSHA
Residential fall protection Presented by Minnesota OSHA Fall protection 29 CFR 1926 Subpart M 1926.501(b)(13) Residential construction policy changes effective June 16, 2011 Residential construction policy
More informationSite check The timber frame pocket guide
PREVIEW PAGES Site check The timber frame pocket guide Sample pages 2 Frame erection ISBN 978-1-909594-65-4 First published in 2018 This is a technical publication for professionals in the built environment
More information* RESIDENTIAL PLAN REVIEW *
CITY OF DES MOINES, IOWA COMMUNITY DEVELOPMENT DEPARTMENT PERMIT AND DEVELOPMENT CENTER 602 Robert D. Ray Drive DES MOINES, IOWA 50309 Phone: 515.283.4200 Facsimile: 515.283.4270 Based on the scope of
More information206 Basic Construction Management
7024_CH13_APP2.QXP_pz 10/23/08 10:13 AM Page 206 206 Basic Construction Management Framing Trade Contractor Job Name, Number Pass/Fail/NA All work complies with locally adopted codes and International
More informationRESIDENTIAL BASEMENT ALTERATIONS GUIDE
RESIDENTIAL BASEMENT ALTERATIONS GUIDE THIS IS A GUIDE ONLY! FOR DETAILED INFORMATION, CONTACT THE BUILDING INSPECTOR OR TOWNSHIP AS ADDITIONAL REQUIREMENTS MAY PERTAIN TO YOUR PROJECT. November 2018 WHITEHALL
More information2003 International Residential Building Code
2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less
More informationChapter 13 - Finish Framing
Chapter 13 - Finish Framing Contents Chapter 13 - Finish Framing... 13-1 Timing & Prerequisites... 13-2 Remove Bottom Plates in Doorways... 13-2 Post LVLs and Girder Trusses... 13-2 Install Framing for
More informationScaffolding. Safety Guide. STOP! Before you climb
Scaffolding Safety Guide Printed FEB 2015 rebr. AUG 2016 Contents Safety Guide Disclaimer... 1 Safety Guide Objectives... 2 Roles & Responsibilities of Workplace Parties Employers, Supervisors, Workers...
More informationTYPICAL SCHEDULE OF COMPONENTS
TYPICAL SCHEDULE OF COMPONENTS ~ Site name ~ Detached 2 storey, 4 bedroom house with integral garage. Fully hipped roof, bedroom 1 to have a raised collar profile and hipped end. ~ 142 m2 gross Timber
More informationPractice Notes For Construction Managers PNCM 7: Timber Formwork First Issue, January 2006
Practice Notes For Construction Managers PNCM 7: Timber Formwork First Issue, January 2006 (Index under: Temporary Works) Contents Page 1. Scope of this Practice Note...1 2. Statutory Ordinance, Regulations
More informationEASY STAIR - EASY - SAFE
EASY STAIR - EASY - SAFE EASIER: Easy Stair makes site access much EASIER by providing stair access prior to the installation of permanent stairs. Why struggle up and down ladders when a simple staircase
More information2014 CATALOGUE
2014 CATALOGUE www.safetyplatforms.co.uk S.T.A. SYSTEM - SAFE TRUSS ACCESS PROBLEM SOLVED! One of the major problems facing the housebuilding industry is how to safely fix bracing timbers to roof trusses.
More informationBuilding Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide
12/29/16 Building Guide Colorado Chapter of the International Conference of Building Officials Building Guide Colorado Chapter of the International Code Council Single Family Residential Enclosing Existing
More informationBuilding Construction Occupations
Job Ready Assessment Blueprint Building Construction Occupations Test Code: 2011 / Version 01 Measuring What Matters Specific Competencies and Skills Tested in this Assessment: Safety and General Knowledge
More informationWORKING AT HEIGHT. The company will comply with the Work at Height Regulations 2005, its schedules and Codes of Practice.
WORKING AT HEIGHT The company will comply with the Work at Height Regulations 2005, its schedules and Codes of Practice. Principally this means that we comply with the hierarchy of risk in that we shall:
More informationINSPECT DIRECT Pty Ltd
Web Page: www.inspectdirect.com.au INSPECT DIRECT Pty Ltd Property Address: Sample.Dilapidation.Report Victoria Building Status / Dilapidation Report This is not a Pest Inspection The Building Status /
More informationSupported Scaffold Inspections
Supported Scaffold Inspections May 2016 Inspect scaffolds and scaffold parts daily, before each work shift, and after any event that may have caused damage. Check to see if power lines near scaffolds are
More informationReliant Holdings Ltd Safety Management System
Preparation: Safety Mgr Authority: President Issuing Dept: Safety Page: Page 1 of 7 Purpose The purpose of this program is to prevent injuries due to falls from elevated work areas and ensure employees
More informationSAFE WORK METHOD STATEMENT
SWMS 002 Erect / Dismantle Single Bay Towers and/or Multiple Bay Towers Page of 9 ABN: 40 088 478 399 This SWMS has been prepared and authorised by OLDFIELDS ACCESS PTY LTD ACN: 088 478 399 Date: Issue
More informationLevel 2 NVQ Diploma in Wood Occupations (Construction)
Qualification Specification ProQual 2015 Contents Page Introduction 3 The Qualifications and Credit Framework (QCF) 3 Qualification profile 4 Rules of combination 5 Centre requirements 8 Support for candidates
More informationLevel 2 NVQ Diploma in Trowel Occupations (Construction) Qualification Specification
Level 2 NVQ Diploma in Trowel Occupations (Construction) Qualification Specification ProQual 2017 Contents Page Introduction 3 Qualification profile 3 Qualification structure 4 Centre requirements 5 Support
More information(Insert Company Name)
Site Specific Fall Protection Plan for Residential Construction (Insert Company Name) This Fall Protection Plan Is Specific For The Following Project: Location of Job Date Plan Prepared or Modified Plan
More informationCity of Rohnert Park Building Department Inspection Descriptions
200 SITE REVIEW: Prior to a permit being issued the Fire / Building Department is authorized to examine existing buildings, structures, and site for which an application has been filed. 201 PRECONSTRUCTION
More informationRISK ASSESSMENT As exhibitions and events are deemed as hazardous environments, it is a legal requirement that all exhibitors and contractors
RISK ASSESSMENT As exhibitions and events are deemed as hazardous environments, it is a legal requirement that all exhibitors and contractors undertake a suitable and sufficient Risk Assessment prior to
More informationUnit Standard 497 Demonstrate knowledge of workplace health and safety requirements Version 7 Level 1 3 Credits. Student Checklist & Instructions
Unit Standard 497 Demonstrate knowledge of workplace health and safety requirements Version 7 Level 1 3 Credits Element I Element 2 Element 3 Identify and describe legislative rights and responsibilities
More information-SQA-SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR
-SQA-SCOTTISH QUALIFICATIONS AUTHORITY Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR -Module Number- 0085137 -Session-1988-89 -Superclass- TE -Title- BUILDING TECHNOLOGY
More informationSafe Work Procedure for installation of
Safe Work Procedure for installation of external cladding This procedure has been formulated to cover safe systems of work for the installation of external cladding. This instruction will be used to reduce
More informationReferences. EM , Sections 22 OSHA 29CFR (Subpart L ) UFGS [Latest] ANSI A
References EM385-1-1, Sections 22 OSHA 29CFR 1926.450 (Subpart L ) UFGS-01 35 29[Latest] ANSI A10.8-1988 What Is A Scaffold? An elevated, temporary work platform Three basic types: Supported scaffolds
More informationTypical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code
Albemarle County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential decks only. Framing requirements are limited to single
More informationNSC North Star Contracting, l.l.c
NSC North Star Contracting, l.l.c PROCEDURES MANUAL PRELIMINARY DATA REQUEST STRUCTURAL 1. Engineer s Frame, Specs & Schedule 2. Roof and Floor Truss Layout, Bearing Point loads for Beams & Girder Locations
More informationINSPECTOR GROUP PTY LTD
Website: http://www.inspectorgroup.com.au Inspector's email: peter@inspectorgroup.com.au Inspector: Peter Hopfinger Building Surveyor & Timber Pest Inspector Registration Number: 2194 Mob: 0414 607 240
More informationUCC Permit Application Procedures
How do I apply for a permit? UCC Permit Application Procedures 1. Please complete the CodeMaster Pan Review Application 2. Please provide the scope of work description and/or construction documents/plans.
More informationOSH5063EP(PRS3607) Workplace and Work Equipment Hazard. Session 9. Working at Height
OSH5063EP(PRS3607) Workplace and Work Equipment Hazard Session 9 Working at Height 1 Introduction The most common fatal type of accident in construction remains falling from a height 2 Introduction Where
More informationPerkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet
Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student
More informationTABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers
version 2.5 updated as of 08.04.2017 2 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers 2.0 ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation
More informationSECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM
Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING
More informationLevel 2 NVQ Diploma in Trowel Occupations (Construction) (QCF) Qualification Specification
(QCF) Qualification Specification ProQual 2015 Contents Page Introduction 3 The Qualifications and Credit Framework (QCF) 3 Qualification profile 4 Rules of combination 5 Centre requirements 6 Support
More informationBP OIL -- TOLEDO REFINERY
BP OIL -- TOLEDO REFINERY Document Type: Procedure Refinery Wide Procedure No.: SAF 076 Effective Date: 3/31/17 Scaffold Procedure Revision No.: 8 Owner: E. Stewart / N. Weber Authorized By: Chris Conley
More informationBuilding Construction Occupations
Job Ready Assessment Blueprint Building Construction Occupations Test Code: 3011 / Version 01 Measuring What Matters Specific Competencies and Skills Tested in this Assessment: Safety and General Knowledge
More informationFall Protection Safety Program and Training Materials
Prepared by Built Insurance Brokerage Fall Protection Safety Program and Training Materials Fall Protection Program... 1 Employee Fall Protection Flyer... 7 Fall Hazard Survey... 8 Requirements for Industrial
More informationAbu Dhabi EHSMS Regulatory Framework (AD EHSMS RF)
Abu Dhabi EHSMS Regulatory Framework (AD EHSMS RF) EHS Regulatory Instrument Code of Practice EHS RI - CoP 41.0 Steel Erection Version 2.0 February 2012 ACKNOWLEDGEMENTS With gratitude Abu Dhabi EHS Center
More informationTECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9
MARKINGWALLING OF SAFETY GLASS SPANDREL CURTAIN PANELS FORMED TO COLDFROM ROOFS STACKED WINDOW 7.2 /25 January ARRANGEMENTS (First Issue) XXXX EXXON QUESTION Which factors should be taken into account
More informationHONG KONG REGULATIONS
HONG KONG REGULATIONS VINEXPO HONG KONG 2018 will take place at The Hong Kong Convention and Exhibition Centre (HKCEC) in the Exhibition Halls on Levels 1 and 3. The documents, ACCESS REQUIREMENTS (document
More informationSCAFFOLDING PROCEDURE
SCAFFOLDING PROCEDURE 1 Table of Contents 1 PURPOSE... 3 2 PROGRAM COMPLIANCE... 3 3 SCOPE... 3 4 DEFINITIONS... 3 5 RESPONSIBILITES... 4 6 SCAFFOLD INSPECTION... 5 7 SCAFFOLD USE... 5 8 SCAFFOLD REQUIREMENTS...
More informationSteps in Building a Shed
Steps in Building a Shed The design and location of your new shed will depend on how it will be used - a shed for storing tools will be much simpler than one you intend to use as a small shop. For example,
More information2010 HSC Construction Sample Answers
2010 HSC Construction Sample Answers Section II This document contains sample answers, or, in the case of some questions, answers could include. These are developed by the examination committee for two
More informationBASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)
BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from
More informationHEALTH AND SAFETY POLICY
SECTION 1. GENERAL POLICY STATEMENT: Director Responsible for Safety: A.C. Appleton The Director responsible for safety will ensure the adoption and maintenance of proper standards of safety, health and
More informationSavard Labor & Marine Staffing, Inc. Fall Prevention Program Rev3/14
Fall Prevention Program Purpose Slips, trips, and falls constitute a significant amount of accidents. They cause 15% of all accidental deaths, and are second only to motor vehicles as a cause of fatalities.
More informationKORA_Req._for_Eng._Studies_on_Stouffer_Apts. KU Reference No
000130 1 PURPOSE: Professional Engineering Consultants, P.A. (PEC) was engaged by University of Kansas Design & Construction Management to perform an assessment of Stouffer Place Apartment Building 20
More informationPlan Check No. Checked by: An Appointment Is Required for Verification
SUPPLEMENTAL CORRECTION SHEET UNREINFORCED MASONRY (URM) RETROFIT ( 2002 LABC ) Plan Check No. Checked by: Permit Appl. # An Appointment Is Required for Verification Job Address: For appt. call: APPLICATION
More informationAdministrative Changes
Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings
More informationDOUBLE SLIDE RAIL INSTALLATION METHOD. Double Slide Rail August
Double Slide Rail August 2015 1 DOUBLE SLIDE RAIL INSTALLATION METHOD Introduction Slide rail shoring systems can be used for trenches up to 12m wide and 6m deep. Module length is determined by panels
More informationHSE Priorities for Construction Designers April 2007
HSE CONSTRUCTION DIVISION PRIORITY RISKS 2004 ONWARDS Safety Priorities Work at height Reducing falls from height through: elimination by design; appropriate selection and use of equipment avoidance or
More informationMaintenance and Refurbishment Works of Quarters Two (2) at FEA s National Control Center, Vuda. Tender Number: MR 334/2017
` Maintenance and Refurbishment Works of Quarters Two (2) at FEA s National Control Center, Vuda. Tender Number: MR 334/2017 1 Fiji Electricity Authority (FEA) is a statutory body vested with the responsibility
More informationSAFETY METHOD STATEMENT
SAFETY METHOD STATEMENT OUR POLICY The safety of our employees and those of our clients is our main priority when carrying out any work on site. This method statement is designed to let you, the client
More informationChapter 14 - Air Sealing
Chapter 14 - Air Sealing Contents Chapter 14 - Air Sealing... 14-1 Pre-Mechanicals Activities... 14-3 Insulate Bathtub Enclosures... 14-3 Insulate Double Walls and Chases... 14-3 Pre-Inspection Checklist...
More informationMr. A Sample Foxes Cottage Bolton Road Bury St Edmunds IP32 2DB 6th January 2014
Mr. A Sample Foxes Cottage Bolton Road Bury St Edmunds IP32 2DB TY MI PI NI CA AT L UR QU E OT SA AT MP IO N LE 6th January 2014 Dear Mr. A Sample, We are pleased to submit the following quotation as requested
More informationSC Construction Area
Job Safety Analysis conducted for SC Construction Area Conducted on 27 Apr 2018 11:33 AM Location Googs Track, Yumbarra SA 5690, Australia Prepared by SafetyCulture Staff Completed on 27 Apr 2018 11:56
More informationUser Guide for New and Altered Commercial Buildings
User Guide for New and Altered Commercial Buildings Please complete this user guide, your building consent application form and compile all the necessary documentation. This user-guide must accompany your
More informationQuality Inspection 8618 London Heights San Antonio, TX Phone: (210)
Quality Inspection 8618 London Heights San Antonio, TX 78254 Phone: (210) 240-0476 PRE DRYWALL INSPECTION REPORT Prepared For: DELETED (Name of Client) Concerning: DELETED, San Antonio, TX 78258 (Address
More informationIntermediate Mapping Grid: CPC30211 Certificate III in Carpentry
Intermediate Mapping Grid: CPC30211 Certificate III in Carpentry 30 units must be completed: 22 core units and 8 elective units Title: Basic Building and Construction Skills 5e Authors: South Western Sydney
More informationConstruction Method Statement
Construction Method Statement Planning Application Phase 17 October 2014 for 79-85 Monier Road London E3 2PS Penten Group Ltd 816 Garratt Lane London SW17 0LZ Tel: 020 8772 4040 Description Contents Page
More informationSTANDARD PRACTICE INSTRUCTION
STANDARD PRACTICE INSTRUCTION DATE: March 1, 2001 SUBJECT: Scaffolding Safety Program. REGULATORY STANDARDS: 29 CFR 1910.28 Safety Requirements For Scaffolding. 29 CFR 1910.29 Manually Propelled Mobile
More informationARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )
8-1200. International Residential Code. ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section 6-9-40) NOTE-This article
More informationSCAFFOLD PLAN SWMS & JSA also known as job safety analysis worksheet or scope of works
Page 1 of 16 SCAFFOLD PLAN SWMS & JSA also known as job safety analysis worksheet or scope of works This SWMS has been developed and authorised by: Scott Butlin Position: Manager Date: 27 th February 2009
More informationChapter 32 - Garage. June 2015 Garages 32-1
Chapter 32 - Garage Contents Chapter 32 - Garage... 32-1 Foundation... 32-3 Walls... 32-3 Roof Framing... 32-4 Roofing... 32-4 Exterior Dow Board... 32-5 Doors... 32-5 Siding... 32-5 Gutters... 32-6 Painting...
More information