University of Delaware

Size: px
Start display at page:

Download "University of Delaware"

Transcription

1 SECTION _ BICYCLE RACKS University Contact: UD Assistant Director of Grounds: Office (302) UD Landscape Planner: Office (302) PART 1 GENERAL Information in this Section is to be followed unless otherwise directed by University of Delaware (UD) Owner Representative and UD Grounds Representative (Assistant Director of Grounds or Landscape Planner). 1.1 SUMMARY A. This section contains information regarding the model and specifications for the layout and installation of bike racks. 1.2 REFERENCES A. See also 4E_DIVISION_32_321623_Sidewalks_Pedestrian Paths for information about the paver pad. 1.3 DESIGN REQUIREMENTS A. Should be conveniently located with sufficient number and spacing to encourage their use. B. A general guideline is to provide one bike rack per three building occupants. C. Bike racks should be placed near PDI entry doors and adjacent to pedestrian paths in a manner that does not block circulatory routes or snow plow access. D. Bike rack areas should be provided good site lighting and, wherever possible, in view of security cameras. E. Typical spacing is no less than on center; adjust based on site conditions. F. Bike Racks should be installed on either concrete or paver pads. See also 4E_DIVISION_32_321623_Sidewalks_Pedestrian Path for pad details. Pad should be a minimum of 8 ft. deep to enable snow plow access around a bike if it remains attached to the rack. 1. When bike rack paver pads are placed in lawn areas, bike racks need to be installed with a minimum of 20 from edge of rack to edge of pavers, to allow for overhang of bike tires. SECTION Bicycle Racks Page 1

2 PART 2 PRODUCTS 2.1 Secure Site Design, LLC Model: BRWS 101Cycle Sentry Series Options: in ground mount (preferred); surface mount is available. Color: Black Powder Coat Capacity: 2 bikes Manufacturer: P.O. Box 6091 Potomac, MD Phone: (888) ; (410) Fax: (410) PART 3 EXECUTION (no content) PART 4 ATTACHMENTS 4.1 Location: Student Services Building, Lovett Ave. Installed in Pavers 4.2 Location: Reading Dormitory Complex Installed in Concrete Pad SECTION Bicycle Racks Page 2

3 4.3 In Ground Mount (Preferred) SECTION Bicycle Racks Page 3

4 4.4 Surface Mount In ground mount is the preferred and recommended installation standard, except only when site conditions require a surface mount option. For surface mount: 1. Use only stainless steel bolts and nuts. 2. Apply "Never Seize" to bolt threads. 3. Bolts should be vandal resistant and not less than 4" long. 4. If being installed into a paver area, a concrete footer shall be poured in place (no less than 8"wide x 24" long x 18" deep). END OF SECTION SECTION Bicycle Racks Page 4

5 SECTION _ Trash and Litter Receptacles PART 1 GENERAL University Contact: UD Assistant Director of Grounds: Office (302) UD Landscape Planner: Office (302) Information in this Section is to be followed unless otherwise directed by University of Delaware (UD) Owner Representative and UD Grounds Representative (Assistant Director of Grounds or Landscape Planner). 1.1 SUMMARY A. This section contains information regarding the model and specifications for the installation of both the recycling and litter receptacles used on campus near dormitories and academic buildings. 1.2 REFERENCES A. 4E_DIVISION 32_321623_Sidewalks_Pedestrian Paths, light traffic for paver pad, if needed 1.3 DESIGN REQUIREMENTS A. Trash and recycling receptacles shall be placed throughout campus, specifically near doorways (except near dormitories), seating areas and high use areas. B. Exact number and locations to be determined on a case by case basis with approval by contacts listed above. C. All trash and recycling receptacles are to be placed on paved areas. D. If a paver pad is constructed, it should be in accordance to 4E_DIVISION 32_321623_Sidewalks_Pedestrian Paths, light traffic. E. All receptacles shall be located and placed in a manner that enables easy access to the swing door. F. Six (6) sets of keys to be supplied with each receptacle for units that have locking doors. SECTION Trash and Litter Receptacles Page 1

6 PART 2 PRODUCTS 2.1 Victor Stanley Ironsites Series: Unit: Victor Stanley Ironsites Series, side door litter receptacle, Model: SD 42 Color: Black Powder Coat; Recycling: VS Blue for Recycling Lid with clear recycled decal with recycling graphics (Dome Lid Layout RD21) Description: VS side door opening, 36 gallon capacity, rigid black plastic liner, key lock box, Lid: Design should prevent water from entering the waster container; therefore, large enough to shed water to the outside of the can. Recreation Resources, Inc. PO Box 371 Kennett Square, PA T: (610 ) or (800) F: (610) resource.com PART 3 EXECUTION 3.1 Receptacles must be secured in place with a concrete footer and stainless steel anchor bolt. 1. Footer Size: no less than 18 x 18 x 18 concrete, 4000 psi. 2. Top of footer shall not be higher than bottom of the paver when pavers are to be the finished surface. If finished surface to be other than pavers, footer shall be placed at grade. Footer shall be separate from surrounding surface. 3. Anchor bolt to be ¾ x 12 stainless steel bolt or all thread and nut. Shall be secured with stainless steel Dynabolt Sleeve Anchors or Trubolt Wedge Anchors, or approved equal. 4. Nut securing receptacle shall be stainless steel and tightened down so receptacle will not rock or move. The ¾ all thread shall have Never Seize applied prior to running nut down to secure unit in place. SECTION Trash and Litter Receptacles Page 2

7 PART 4 ATTACHMENTS 4.1 Gilbert Redding Dormitory Blue: Recycling; Black: Trash END OF SECTION SECTION Trash and Litter Receptacles Page 3

8 SECTION _Site Seating and Tables University Contact: Office of the Architect and Campus Planner: (302) PART 1 GENERAL 1.1 SUMMARY Information in this Section is to be followed unless otherwise directed by University of Delaware (UD) Owner Representative. All site furniture to be approved by University of Delaware Campus Architect. A. This section contains information about outdoor seating that includes tables and chairs, and excludes exterior benches. 1.2 REFERENCES A. For information on exterior benches, refer to: 4C DIVISION 12_ Exterior Benches PART 2 PRODUCTS 2.1 Parc Centre Café Tables and Chairs A. Café Tables B. Chairs 1. Name: Parc Centre 2. Style: Freestanding Size: 28 Square Top Color: Silver or Black Powder Coat; TBD on a project by project basis Interdisciplinary Science and Technology Building: Silver 1. Name: Parc Centre 2. Style: Freestanding Chair, with arms Size: No content. Color: Silver or Black Powder Coat; TBD on a project by project basis Interdisciplinary Science and Technology Building: Silver REV: 09 Sept 14 SECTION Site Seating and Tables Page 1

9 2.2 Manufacturer/Suppliers A. For Parc Centre: Landscape Forms, Inc. 431 Lawndale Avenue Kalamazoo, MI Phone: (800) Fax: (269) PART 3 EXECUTION (no content) REV: 09 Sept 14 SECTION Site Seating and Tables Page 2

10 PART 4 ATTACHMENTS 4.1 Parc Centre Silver Powder Coat Table and Chairs Location: ISEB REV: 09 Sept 14 SECTION Site Seating and Tables Page 3

11 4.2 Parc Centre Silver Powder Coat Chairs Location: ISEB END OF SECTION REV: 09 Sept 14 SECTION Site Seating and Tables Page 4

12 SECTION _ Site Seating: Exterior Benches PART 1 GENERAL University Contact: UD Assistant Director of Grounds: Office (302) UD Landscape Planner: Office (302) Information in this Section is to be followed unless otherwise directed by University of Delaware (UD) Owner Representative and UD Grounds Representative (Assistant Director of Grounds or Landscape Planner). 1.1 SUMMARY A. Information in this section pertains to outside benches; for other exterior seating refer to: 4C_DIVISION 12_ Site Seating and Tables B. Two types of benches currently used are: 1.2 REFERENCES 1. Victor Stanley Bench (Recreation Resources) o Used primarily in Central Campus areas and historic areas of campus. 2. Scarborough Bench (Landscape Forms) o Used primarily in South Campus and North Campus areas. A. 4E DIVISION 32_ Sidewalks _ Pedestrian Paths 1.3 DESIGN REQUIREMENTS A. Ample lighting should be provided. B. Configuration of seating areas should be diverse to encourage a variety of interaction opportunities. C. Benches should be installed on paver pads or paved surfaces, with concrete footers and anchor bolts. Paver pads should be connected to adjacent paving areas. Refer to 4E DIVISION 32_ Sidewalks _ Pedestrian Paths for additional information. SECTION Site Seating: Exterior Benches Page 1

13 D. Concrete Footers 1. A concrete footer shall be poured in place under each leg. 2. Dimensions of footer shall be no less than 10 wide x 24 long x 18 deep. 3. Top of footer should not extend beyond bottom of paver. E. Anchor Bolts PART 2 PRODUCTS 1. Shall be of sufficient length to allow for full penetration into the concrete footer. 2. Shall be painted glossy black and shall be the diameter of both holes. 3. Shall be firmly torqued in place to reduce vandalism and theft of bench. 4. Shall be secured with stainless steel Dynabolt Sleeve Anchors or Trubolt Wedge Anchors, or approved equal. 2.1 Victor Stanley Classic Series Bench Model: C 10 Ipe Material: Contoured Bench with Ipe slats Length: 6 Frame: Black Manufacturer: Recreation Resources USA P.O. Box 371 Kennett Square, PA Phone: (610) Fax: (610) resource.com SECTION Site Seating: Exterior Benches Page 2

14 2.2 Scarborough Bench Style: Backed Insert: Horizontal Strap Length: 72 Color: Black Powdercoat Standard Features: Free standing/ Surface Mountable Manufacturer: Landscape Forms, Inc. 431 Lawndale Avenue Kalamazoo, MI Phone: (800) Fax: (269) PART 3 EXECUTION (no content) SECTION Site Seating: Exterior Benches Page 3

15 PART 4 ATTACHMENTS 4.1 Victor Stanley Bench. Location: Redding Dormitory SECTION Site Seating: Exterior Benches Page 4

16 4.2 Scarborough Bench on Brick Pad END OF SECTION SECTION Site Seating: Exterior Benches Page 5

ROLLING RACK. Simple Security

ROLLING RACK. Simple Security Simple Security The graceful design and high security of the Rolling Rack has made this type of bike rack a standard for many schools and communities. The Rolling Rack can be used as a single-sided or

More information

University of New Mexico Environmental Services Design & Development Standard Requirements

University of New Mexico Environmental Services Design & Development Standard Requirements University of New Mexico Environmental Services Design & Development Standard Requirements Please review the following standards to be considered on all construction specifications. Your consideration

More information

Section 1 OBC FADS /13 Access to Parking Areas

Section 1 OBC FADS /13 Access to Parking Areas Section 1 OBC 3.8.2.2 4.3.12/13 Access to Parking Areas A barrier-free path of travel is provided from: a) the entrance to the exterior parking area b) at least one parking level where a passenger elevator

More information

B R OA DWAY RAC K. High Security

B R OA DWAY RAC K. High Security B R OA DWAY RAC K High Security The Broadway Rack is a great fit on Broadway or in areas where maximum security is a top priority. Made of thick, two-inch square steel, the Broadway Rack renders pipe-cutters

More information

INDUSTRIAL GUARDRAIL SYSTEMS

INDUSTRIAL GUARDRAIL SYSTEMS INDUSTRIAL GUARDRAIL SYSTEMS STRONGEST GUARDRAIL ON THE MARKET MANUFACTURED IN THE U.S.A. BEST PRICES MOST VARIETIES HEAVY DUTY ONE-LINE OR TWO-LINE Posts: 4 Sched 80 pipe Rail: 6 Sched 40 pipe Sleeved

More information

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available. Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon

More information

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Model # 800SM-PS3. 8/3/2016 Page 1 of 8 Model # 800SM-PS3 8/3/2016 Page 1 of 8 /3/2016 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Conductor & Signal Training Tables

Conductor & Signal Training Tables Conductor & Signal For exciting tools that motivate employees and instructors Training matters more than ever and so does enthusiasm among the participants. Every element of the Conductor and Signal contributes

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11294 - Stainless Steel Sluice Gates C O N T E N T S PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 DEFINITIONS... 1 1.04 DESIGN REQUIREMENTS...

More information

GV 001 Equipment Bases and Enclosures General Information

GV 001 Equipment Bases and Enclosures General Information Eq u ip me n tba s e s a n d En c lo s u re s Ge n e ra lin fo rma tio n E n g in e e r :R.An th o n GV0 0 1 Ap p r o v e r :Jo s h u a Jo n e s Ap r 1 7 2 0 Ap r1 7 GV 001 Equipment Bases and Enclosures

More information

Temporary Exterior Signs and Postings Policy

Temporary Exterior Signs and Postings Policy Temporary Exterior Signs and Postings Policy May 24, 2011 PURPOSE The university recognizes that signs including posters, banners, flyers, notices, brochures, etc. are a means for communicating information

More information

Testing and Evaluation of Detectable Warning Systems 2005 NESMEA Meeting

Testing and Evaluation of Detectable Warning Systems 2005 NESMEA Meeting Testing and Evaluation of Detectable Warning Systems 2005 NESMEA Meeting What is a Detectable Warning? A surface feature that aids persons with visual impairments in detecting hazards Requirement of Americans

More information

Pueblo Estrella Homeowners Association Architectural Guidelines

Pueblo Estrella Homeowners Association Architectural Guidelines Pueblo Estrella Homeowners Association Architectural Guidelines Approved 06 May 2008 Effective 01 August 2008 Amended 11, May 2010 Sections L,Q,S A. ANTENNAS AND SATELLITE DISHES Antennas and satellite

More information

Model # 922-S4. 12/18/2013 Page 1 of 8

Model # 922-S4. 12/18/2013 Page 1 of 8 Model # 922-S4 12/18/2013 Page 1 of 8 2/18/2013 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION SECTION 1101 SIGNALS AND APPURTENANCES PART 1 GENERAL 1.4 SUBMITTALS E. Submit warranty for all supplied material and workmanship for a period of two years from final acceptance. The warranty must state

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment

More information

PRODUCT EVALUATION Effective Date: June 1, 2013 GDR-40

PRODUCT EVALUATION Effective Date: June 1, 2013 GDR-40 TEXAS DEPARTMENT OF INSURANCE Engineering Services Program / MC 103-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective

More information

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

SECTION BASIC ELECTRICAL MATERIALS AND METHODS SECTION 26 05 05 BASIC ELECTRICAL MATERIALS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the limited scope construction materials and methods for application with electrical installations as follows:

More information

A Consumer s Guide. to outdoor kitchens. A comparison of. wood, stucco, stone, Stainless Steel and polymer

A Consumer s Guide. to outdoor kitchens. A comparison of. wood, stucco, stone, Stainless Steel and polymer A Consumer s Guide to outdoor kitchens A comparison of wood, stucco, stone, Stainless Steel and polymer - WOOD - ADVANTAGES Wide selection - wood cabinets can be purchased in any big box store or kitchen

More information

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Sight-Line Command Center Consoles. SeeAppendix A - C for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

FACT SHEET #2 DECK INFORMATION

FACT SHEET #2 DECK INFORMATION Borough of Doylestown Building and Zoning Department 57 West Court Street, Doylestown, PA 18901 215.345.4140 FACT SHEET #2 DECK INFORMATION BACKGROUND The provisions of the PAUCC. ICC Property Maintenance

More information

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing MERCHANTS METALS SECTION 32 31 13 COLORBOND CHAIN LINK FENCE AND GATES 2014 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance requirements,

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following: SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN 1. SCOPE This specification covers the design, fabrication and testing of tubular section, galvanised steel friction fit jointed street light columns of

More information

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS Model # 349S-P6 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic coated elements. Ultra Play guarantees all

More information

DIVISION PARKING STRUCTURES

DIVISION PARKING STRUCTURES DIVISION 13 00 40 PARKING STRUCTURES 1. Design Requirements 1.1. A parking design professional must be used to provide the functional and structural design of the facility. 1.2. A traffic analysis is required

More information

Proudly Made in the U.S.A.

Proudly Made in the U.S.A. 5-Year Warranty Proudly Made in the U.S.A. Cast-In-Place (wet-set) 2 Cast-In-Place (wet-set) Tactile Proudly Made in the U.S.A. In stock colors White 37875 Brick Red 20109 Yellow 33538 Blue 15187 Safety

More information

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms REV. 9/08 Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms SKYTRON MOUNTING STRUCTURES for Ceiling Mounted Equipment Foreword Skytron s objective is to provide a program and guideline to assist

More information

Model # 158-P4. 12/12/2013 Page 1 of 11

Model # 158-P4. 12/12/2013 Page 1 of 11 Model # 158-P4 12/12/2013 Page 1 of 11 2/12/2013 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Partitions. 24/7 Security

Partitions. 24/7 Security Partitions 24/7 Security Partition Applications Warehouse Storage Partition - 4 Robotic Guards for Robot and Conveyor Protection - 5 Rack Guards for Back-of-Rack Protection - 6 Sheet Metal Welding Cell

More information

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Model # 238HS-P8. 4/27/2011 Page 1 of 11 Model # 238HS-P8 4/27/2011 Page 1 of 11 4/27/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using

More information

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures. BID OPPORTUNITY NO. 253-2011 PAGE 1 OF 7 PART 1 GENERAL 1.1 REFERENCES.1 American Society of Mechanical Engineers (ASME).1 ASME B31.1, Power Piping, B31.3 Process Piping, B31.9 Building Services Piping..2

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

Record Master SHELVING SYSTEMS

Record Master SHELVING SYSTEMS Record Master SHELVING SYSTEMS Storage Solutions Four-Post Heavy-Duty X-Ray Storage Case Style Aisle-Saver Mobile by Borroughs Welcome to Record Master Easy. Organized. Accessible. Many business and professional

More information

Introduction. Disclaimer. Table of contents

Introduction. Disclaimer. Table of contents Updated July 18, 2012 Introduction The Cambridge Elevating Limited-Use / Limited-Application Elevator is designed to service schools, libraries, low rise, low occupancy commercial buildings, churches and

More information

Zurn Z874. Trench Drain System. Installation Instructions

Zurn Z874. Trench Drain System. Installation Instructions Zurn Z874 Trench Drain System Installation Instructions Z874 Accessories Trench Drain System Below are the components of the Z874-X trench drain typical to an installation. Check your order to verify you

More information

Dexco Structural I-Beam Cantilever Racks Versatile, durable storage solutions for materials of considerable length and mass

Dexco Structural I-Beam Cantilever Racks Versatile, durable storage solutions for materials of considerable length and mass Dexco Structural I-Beam Cantilever Racks Versatile, durable storage solutions for materials of considerable length and mass Dexco Cantilever Rack Systems offer the strength, durability and layout to store

More information

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers) SECTION 10 51 00 Summit Phenolic Lockers (Solid Phenolic Lockers) Part 1-General 1.01 Summary A. Section includes: solid phenolic lockers solid phenolic benches 1.02 Submittals A. Submittals: Comply with

More information

SECTION POROUS PAVEMENT SYSTEM

SECTION POROUS PAVEMENT SYSTEM SECTION 02795 POROUS PAVEMENT SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Porous grass paving grid system. 1.2 RELATED SECTIONS A. Section 02300 - Earthwork. B. Section 02620 Sub-Drainage System. C.

More information

ASSEMBLY INSTRUCTIONS for DATASAFE TM HX and HX FRONT TERMINAL UBC BATTERY RACKS

ASSEMBLY INSTRUCTIONS for DATASAFE TM HX and HX FRONT TERMINAL UBC BATTERY RACKS US-HXRACK-IM-002 ASSEMBLY INSTRUCTIONS for DATASAFE TM HX and HX FRONT TERMINAL UBC BATTERY RACKS Read all instructions carefully and observe all warnings before installation. See Installation, Operation

More information

Introducing a complete line of Limestone Classics TM Building Veneers from Indiana Limestone Company. Genuine Indiana Limestone the natural and

Introducing a complete line of Limestone Classics TM Building Veneers from Indiana Limestone Company. Genuine Indiana Limestone the natural and Introducing a complete line of Limestone Classics Building Veneers from Indiana Limestone Company. Genuine Indiana Limestone the natural and innovative design solution for your residential and commercial

More information

blinds are different!

blinds are different! releases! 2015 blinds are different! muddy construction! There is no comparison, Muddy is superior to other fiberglass or molded plastic setups. Therma-tek: Innovative structural insulated design provides

More information

Embry-Riddle Aeronautical University Signage Specifications 03/25/2008

Embry-Riddle Aeronautical University Signage Specifications 03/25/2008 Embry-Riddle Aeronautical University Signage Specifications 03/25/2008 The following specifications are for the fabrication, painting of signs, graphics& installation of 4 (four) typical sign designs for

More information

SECTION METAL FLOOR PLATE STAIRS

SECTION METAL FLOOR PLATE STAIRS SECTION 05513 - METAL FLOOR PLATE STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual Series 200 UL Introduction Series 200 UL Introduction SnapNrack Series

More information

SECTION COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES

SECTION COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES SECTION 10712 COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Functional exterior shutters. B. Exterior shutter hardware. 1.2 RELATED SECTIONS A. Section 09900 - Paints

More information

Architectural Specifications, Section Phenolic Lockers

Architectural Specifications, Section Phenolic Lockers Architectural Specifications, Section 10500 Phenolic Lockers Hollman, Inc., 1825 W. Walnut Hill Lane, Irving, TX 75038, (972) 815-4000, www.hollman.com 1.0 GENERAL 1.1 SECTION INCLUDES A. Phenolic Lockers.

More information

Diffused Aeration Piping Equipment

Diffused Aeration Piping Equipment 1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections

More information

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9080 - Concrete Steps, Handrails, and Safety Rail CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART - GENERAL.0 SECTION INCLUDES

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

Model # 358-R48. 7/7/2011 Page 1 of 11

Model # 358-R48. 7/7/2011 Page 1 of 11 Model # 358-R48 7/7/2011 Page 1 of 11 7/7/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural cantilever rack design. In addition, it is

More information

HIGH PILED COMBUSTIBLE STORAGE CITY OF NOVI SUBMITTAL CHECKLIST In Accordance with Chapter 23 of the 2006 International Fire Code

HIGH PILED COMBUSTIBLE STORAGE CITY OF NOVI SUBMITTAL CHECKLIST In Accordance with Chapter 23 of the 2006 International Fire Code Project Name/Tenant: HIGH PILED COMBUSTIBLE STORAGE CITY OF NOVI SUBMITTAL CHECKLIST In Accordance with Chapter 23 of the 2006 International Fire Code Site Address: Applicant: Phone: Bldg/Unit/Suite: A

More information

Residential Products

Residential Products 800.854.9724 WWW.BILCO.COM Residential Products Basement Doors Basement doors are ideal for access to basement storage areas and for moving large items into finished basement areas. The wide opening allows

More information

Components. Jacks 2 Leg Assembly. Jacks. Typical Frame

Components. Jacks 2  Leg Assembly. Jacks. Typical Frame ShorFast Components ShorFast Leg Assembly The ShorFast legs are manufactured entirely from aluminum. The body is extruded with four large keyways to accept ShorFast Frames and provides a positive rigid

More information

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR Page 1 of 6 SECTION 08 39 80 U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR U.S. Aluminum has designed one of the most demanding air and water protection products, the BAL- 350 Small

More information

Exhibit A EXISTING RTU TO BE SCREENED ' BUILDING A EXISTING TO BE RENOVATED 2,100 SF EXISTING LANDSCAPE AREA TO REMAIN NEW ENTRANCE AREA

Exhibit A EXISTING RTU TO BE SCREENED ' BUILDING A EXISTING TO BE RENOVATED 2,100 SF EXISTING LANDSCAPE AREA TO REMAIN NEW ENTRANCE AREA Received April 9, 08 - AR Exhibit A MIXED USE WITH RESIDENTIAL 44' PROPOSED BUILDING TO MIXED USE BUILDING 6.8' LOT TO LOT DISTANCE TO RESIDENTIAL USE 87.5' BUILDING TO MIXED USE BUILDING 0' 78' 4.6' 0.64'

More information

Sign & Post Installation. Standard Specifications and Standard Drawings. July 2017 Edition

Sign & Post Installation. Standard Specifications and Standard Drawings. July 2017 Edition Standard Specifications Sign & Post Installation Utility Services Department 500 George Street North, Peterborough, Ontario, K9H 3R9 Transportation Division Telephone: 705-742-7771 Fax: 705-876-4621 Sign

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

SECTION CHAIN LINK FENCES AND GATES (PARK)

SECTION CHAIN LINK FENCES AND GATES (PARK) SECTION 02821 CHAIN LINK FENCES AND GATES (PARK) PART I GENERAL 1.1 SECTION INCLUDES A. Installation of chain link fences, and gate units provided by single source including erection accessories, fittings,

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems.

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems. SECTION 26 05 29 HANGERS AND SUPPORTS FOR PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Hangers and supports for electrical equipment and systems. 1.2 DEFINITIONS A. EMT: Electrical

More information

Section X - Miscellaneous

Section X - Miscellaneous Section X - Miscellaneous A. Introduction This section provides design criteria, specific requests/recommendations and preferences related to specifying and constructing systems and materials used in HRSD

More information

EAGLE HARBOR HOMEOWNERS ASSOCIATION

EAGLE HARBOR HOMEOWNERS ASSOCIATION EAGLE HARBOR HOMEOWNERS ASSOCIATION RULES AND REGULATIONS The following Rules and Regulations have been approved by the Board of Directors. These have been formulated to provide criteria for consistent

More information

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4 x 4 x 3/8 Brace. C8 x 4.25 Strut. WT9 x 17.5. Sign length minus Adjust to avoid interference with sign legend A Deck fascia A 6" Equal Equal 6" Sign length (L) varies 6 to 12 PLAN 0 CONNECTION (DECK FASCIA) Angle connection assembly F Face of concrete

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

Model # 338S-OP. 9/30/2011 Page 1 of 13

Model # 338S-OP. 9/30/2011 Page 1 of 13 Model # 338S-OP 9/30/2011 Page 1 of 13 9/30/2011 Page 2 of 13 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

WALL MOUNTED ARTICULATING JIB CRANE

WALL MOUNTED ARTICULATING JIB CRANE SECTION 14656 WALL MOUNTED ARTICULATING JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and

More information

CITY OF FARGO SPECIFICATIONS SIGNING

CITY OF FARGO SPECIFICATIONS SIGNING SIGNING PART 1 DESCRIPTION OF WORK The work to be done under this section of the Specifications and the accompanying plans consists of furnishing all labor, material and accessories necessary to complete

More information

ADDENDUM NO. 2 PROJECT: COASTLINE COLLEGE

ADDENDUM NO. 2 PROJECT: COASTLINE COLLEGE ADDENDUM NO. 2 Coast Community College District Purchasing Department PROJECT: COASTLINE COLLEGE Newport Learning Center Signage Project BID NO: 20 NOTICE TO BIDDERS ON THE ABOVE PROJECT: This addendum

More information

UNDERGROUND SERVICES SECONDARY

UNDERGROUND SERVICES SECONDARY Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-

More information

Electric Service Standards

Electric Service Standards V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are

More information

THOMAS JEFFERSON UNIVERSITY HOSPITAL STANDARD OPERATING PROCEDURE FOR THE BUILD OUT OF TELECOMMUNICATIONS ROOMS AND ASSOCIATED SPACES

THOMAS JEFFERSON UNIVERSITY HOSPITAL STANDARD OPERATING PROCEDURE FOR THE BUILD OUT OF TELECOMMUNICATIONS ROOMS AND ASSOCIATED SPACES THOMAS JEFFERSON UNIVERSITY HOSPITAL STANDARD OPERATING PROCEDURE FOR THE BUILD OUT OF TELECOMMUNICATIONS ROOMS AND ASSOCIATED SPACES PREPARED BYBALA CONSULTING ENGINEERS, INC FOR THOMAS JEFFERSON UNIVERSITY

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Technical Data Sheet: The Corrugated HC-Omega

Technical Data Sheet: The Corrugated HC-Omega Performance Structural Concrete Solutions, LLC P.O. Box 2377, Davidson, NC 28036-2377 P: 980-333-6414 info@pscs-llc.com www.pscs-llc.com Technical Data Sheet: The Omega Figure 1. Omega armor joint on grade.

More information

Model # 358H-PR. 4/8/2011 Page 1 of 12

Model # 358H-PR. 4/8/2011 Page 1 of 12 Model # 358H-PR 4/8/2011 Page 1 of 12 4/8/2011 Page 2 of 12 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Wears Like Iron Because it is Iron!

Wears Like Iron Because it is Iron! Detectable WARNING PLATES Wears Like Iron Because it is Iron! Exceptional Durability Superior Performance Simple Installation Withstand Even the Harshest of Weather Conditions Regulatory-compliant cast

More information

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16 long / 1/2 thick or 16 oz. copper Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)

More information

Requirement checklist to obtain a building permit for a: RESIDENTIAL POLE BUILDING

Requirement checklist to obtain a building permit for a: RESIDENTIAL POLE BUILDING Requirement checklist to obtain a building permit for a: RESIDENTIAL POLE BUILDING 2 Completed copies of the two page application (must be legible and signed) Land Use Permit (signed/approved by the Municipality)

More information

VertiGreen Modular Living Wall System Installation Instructions (VGM-06 and VGM-10 Wall Mount)

VertiGreen Modular Living Wall System Installation Instructions (VGM-06 and VGM-10 Wall Mount) VertiGreen Modular Living Wall System Installation Instructions (VGM-06 and VGM-10 Wall Mount) This instruction is a guide to installing the VertiGreen Modular Living Wall System on a wall or support structure.

More information

Box Rail. Single Box Rail Bracket

Box Rail. Single Box Rail Bracket HANGERS & RAILS Box Rail Accordion Door Hangers Max. Door Weight (SWL) 450 lbs Meets ANSI/BHMA A156.14, Grade 1. Rail is carefully formed to give an even tread to hanger wheels. Packaging: Bundled without

More information

University of Toronto Cleaning Specifications

University of Toronto Cleaning Specifications Revised/Updated February 1-2013 University of Toronto Cleaning Specifications AREA TYPE Task To Be Completed Frequency Main Entrance 1 Clean both sides of door glass including side lights. Daily & 2 Clean

More information

MODEL: IMPULSE - DUAL SIT/STAND CONSOLES

MODEL: IMPULSE - DUAL SIT/STAND CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Impulse Dual Sit/Stand Consoles. See Appendix A - D for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

This section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems.

This section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems. NORTH MARIN WATER DISTRICT STANDARD SPECIFICATIONS SECTION 15056 DUCTILE-IRON PIPE AND FITTINGS PART 1 GENERAL 1.01 DESCRIPTION This section includes materials and installation of ductile-iron pipe and

More information

L i t t e r B i n s. We manufacture three sizes of litter bin: 55 litre, 110 litre, and 220 litre.

L i t t e r B i n s. We manufacture three sizes of litter bin: 55 litre, 110 litre, and 220 litre. We manufacture three sizes of litter bin: 55 litre, 110 litre, and 220 litre. L i t t e r B i n s All have strongly constructed steel frames and are designed to complement our range of seats. The most

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

A/E Design Deliverable Checklist

A/E Design Deliverable Checklist A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic

More information

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,

More information

Commercial Tax Abatement

Commercial Tax Abatement A confirmation letter is issued by the City upon receipt of this application. This application is not effective and not considered filed until the confirmation letter has been issued. Filing does not assure

More information

PRODUCT CATALOG

PRODUCT CATALOG FENCE PRODUCT CATALOG 1.866.648.9336 www.simtekfence.com DREAM YARDS DON T JUST HAPPEN, THEY RE BUILT ON A FOUNDATION OF QUALITY AND TIMELESS DESIGN. WE CREATE BEAUTIFUL YARDS SimTek decorative rock walls

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work. SECTION 10 5113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

VPL-3200B Residential Vertical Platform Lift Technical Specifications

VPL-3200B Residential Vertical Platform Lift Technical Specifications Page 1 of 5 VPL-3200B Residential Vertical Platform Lift Technical Specifications MODEL NUMBER: VPL-3200B Series: Models VPL-3210B, VPL-3212B and VPL-3214B (DC-powered units) U.S. F.D.A. CLASSIFICATION:

More information

MDS TL5 Minimum Deflection Systems

MDS TL5 Minimum Deflection Systems MDS Minimum Deflection Systems Approvals FHWA NCHRP 350 MASH EN1317 H4 MDS BARRIERS Bridge & Road STEEL BARRIER SYSTEMS Page Page 1 1 V11 MDS BARRIERS Run-off-road crashes are one of the most common types

More information

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA TABLE OF CONTENTS TABLE OF CONTENTS SAFETY REGULATIONS MATERIALS REQUIRED ASSEMBLY ENGINEERING DRAWINGS TERMS AND CONDITIONS

More information

MDS TL4 Minimum Deflection Systems

MDS TL4 Minimum Deflection Systems MDS Approvals FHWA NCHRP 350 MASH-08 EN1317 H2 Bridge & Road STEEL BARRIER SYSTEMS Page 1 V11 Run-off-road crashes are one of the most common types of crashes in urban and highway environments. Installing

More information

PH6000. Key Features

PH6000. Key Features Phenolic Locker Series PH6000 Key Features ½ inch doors and end panels Durable, backed by a 20 year warranty. Ideal choice for wet-use areas including pools and recreation centers Graffiti resistant, permanent

More information

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING 7160 Krick Rd., Walton Hills, OH 44146 800-321-3827 - Tel 440-439-8650 - Fax 440-439-6889 SECTION 12 48 16 ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING PART 1. GENERAL 1.01 SUMMARY: This section includes

More information

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service. CHAPTER3 Clark Public Utilities Commercial Electric Service Handbook Commercial Underground Services Preparing for the installation The following checklist will assist in preparing a project for the installation

More information

Absco Premier Garden Shed Assembly Instructions Model: 30232G

Absco Premier Garden Shed Assembly Instructions Model: 30232G Absco Premier Garden Shed Assembly Instructions FRONT: 3.00m SIDE:.6m HEIGHT:.00m 360mm CONCRETE SLAB 3100mm CONCRETE WHEN LAYING YOUR CONCRETE SLAB, ENSURE THERE IS A REBATED EDGE 5mm DEEP AROUND THE

More information