1 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: SECTION (08520) - ALUMINUM WINDOWS 1. Operating and Fixed Aluminum Window Units a. Horizontal Sliding Units b. Horizontal Sliding Units Above Louver in Integral Master Frame. 1) Louvers to be provided by Window Manufacturer 2. Perimeter Sealant 3. Glass and Glazing 4. Wood Blocking, Shims, Anchors, Clips, and all accessories necessary for a complete installation. 5. All Aluminum Trim and Closure Pieces 6. All Operable Window and Door Hardware B. Related Sections: 1.02 REFERENCES 1. Section (07620) - Sheet Metal Flashing and Trim 2. Section (07920) Joint Sealants 3. Section (08410) - Aluminum Entrances and Storefront 4. Section (08800) - Glazing A. The Aluminum Association (AA) 1. "Aluminum Design Manual 2000: Specifications for Aluminum Structures" B. American Architectural Manufacturers Association (AAMA) Publications: Voluntary Specification for Anodized Architectural Aluminum "Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall Sections" "Standard Practice for Installation of Windows with a Mounting Flange in Stud Frame Construction" "Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels" "Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels" C. American National Standards Institute (ANSI) Publications: 1. Z97.1 "Performance Specifications and Methods of Test for Safety Glazing Materials Used in Buildings" D. ASTM International (ASTM) Publications: 1. C1036 Standard Specification for Flat Glass PAGE 1

2 2. C1048 Standard Specification for Heat-Treated Flat Glass Kind HS, Kind FT Coated and Uncoated Glass 3. E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements 4. E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen 5. E330 Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference 6. E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference 7. E413 Classification for Rating Sound Insulation 8. E547 "Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference" 9. E774 Standard Specification for Sealed Insulating Glass Units 10. E1886 "Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials" 11. E1996 "Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes" 12. F588 "Standard Test Methods for Measuring the Forced Entry Resistance of Window Assemblies, Excluding Glazing Impact" E. Glass Association of North America (GANA) 1. "GANA Glazing Manual" F. Federal Specifications (FS) Publications: 1. FS-RR-W-365A "Wire Fabric (Insect Screening)" G. Insulating Glass Certification Council (IGCC) H. Insulating Glass Manufacturers Alliance (IGMA) Publications: 1. Glazing Guidelines I. National Fenestration Rating Council (NFRC) J. Screen Manufacturers Association (SMA) Publications: "Specifications for Aluminum Tubular Frame Screens for Windows" K. U.S. Consumer Product Safety Commission (CPSC) Publications: CFR Part 1201 "Safety Standard For Architectural Glazing Materials" L. Window and Door Manufacturers Association (WDMA) Publications: 1. ANSI/AAMA/WDMA 101/I.S.2/NAFS-02 Voluntary Performance Specification for Windows, Skylights and Glass Doors 2. AAMA/WDMA/CSA 101/I.S.2/A Standard/Specification for Windows, Doors and Unit Skylights REVISED: 01/06/14 PAGE 2 FILE: CFRST-Aluminum Windows CFRST SPECMSTR-NEW BUILD 2014, Marriott International, Inc.

3 1.03 SUBMITTALS A. General: Submit the following in accordance with Conditions of Contract and Division 01 Specification Sections. B. Submit Letter of Conformance in accordance with Section (01330) indicating specified items selected for use in project with the following supporting data DEFINITIONS 1. Product data for each type of aluminum window specified, including standard construction details, dimensions of individual components, profiles, finishes, hardware, and accessories. 2. Shop drawings for each type of window specified, including 1/4-inch scale wall elevations, typical unit elevations at 3/4 inch scale glazing details, full-size details of typical composite members and the following: a. Panning Details. b. Flashing and drainage details. c. Mullion details, including reinforcement and stiffeners. d. Joinery details. 3. Product certificates signed by the window manufacturer certifying that window units comply with specified performance requirements. A. Performance grade number, included as part of the AAMA/WDMA/CSA 101/I.S.2/A product designation code, is the actual design pressure in pounds force per square foot used to determine structural test pressure and water test pressure QUALITY ASSURANCE A. All window units shall be manufactured by a single source. 1. All windows in any one project must be by the same manufacturer and with comparable frame depth, profile, glazing bite and installation requirements. Manufacturer must provide a window system that can incorporate all window configurations used on the project. 2. Standards: Requirements for aluminum windows, terminology and standard of performance, and fabrication workmanship are those specified and recommended in AAMA/WDMA/CSA 101/I.S.2/A and The Aluminum Association (AA). a. All window units shall be labeled as conforming to AAMA/WDMA/CSA 101/I.S.2/A The label shall state the name of the manufacturer, the approved labeling agency and the product designation as specified in AAMA/WDMA/CSA 101/I.S.2/A b. All testing shall be conducted using AAMA/WDMA/CSA 101/I.S.2/A Gateway Performance minimum specified test sizes. 3. Provide aluminum windows of the performance class and grade indicated that comply with AAMA/WDMA/CSA 101/I.S.2/A B. Sections , , and to be furnished by single source insuring product compatibility and coordination. C. Certify that windows have been tested in accordance with American Architectural Manufacturers Association (AAMA/WDMA) Specification for Performance Class specified complying with the following performance standards: PAGE 3

4 1. AAMA/WDMA/CSA 101/I.S.2/A Performance Requirements: Provide aluminum windows of the performance class and grade indicated that comply with AAMA/WDMA/CSA 101/I.S.2/A a. Performance Class: CW b. Performance Grade: Uniform Structural Properties (ASTM E330): Pressure acting inward and outward. Window to be operable and maximum.4% permanent deformation, per member, when tested at a static air pressure difference of the following: a. Class CW-35: 45.0 PSF 3. Water Resistance (ASTM E331 and ASTM E547): No water penetration at test pressures indicated. a. Class CW-35: 4.50 PSF 4. Air Leakage (ASTM E283): a. Sliding Windows: Maximum 0.37 CFM per sq./ft. of total exterior surface area, when tested at a static air pressure difference of 1.57 PSF minimum. b. Fixed Windows: Maximum 0.15 CFM per sq. ft. of total exterior surface area, when tested at a static air pressure difference of 1.57 PSF minimum. c. Forced Entry Resistance (ASTM F588): To performance level 10. D. Glazing Standards: Comply with recommendations of Glass Association of North America (GANA) "Glazing Manual" and "Sealant Manual" except where more stringent requirements are indicated. Refer to those publications for definitions of glass and glazing terms not otherwise defined in this section or other referenced standards. 1. Safety Glazing Products: Comply with testing requirements in CPSC 16 CFR Part a. Subject to compliance with requirements, obtain safety glazing products permanently marked with certification label of the Safety Glazing Certification Council or another certification agency acceptable to authorities having jurisdiction. 2. Insulating glass shall comply with standard for construction and insulating value as established by: a. Insulating Glass Manufacturers Alliance (IGMA). b. Insulating Glass Certification Council (IGCC) 3. Glazing and Sealant: Per manuals published by the Flat Glass Marketing Association (FGMA). Glazing and sealant to match approved colors for all aluminum framing DELIVERY, STORAGE, AND HANDLING A. Transportation and Handling: Transport products by methods to avoid product damage; deliver in undamaged condition in manufacturer's unopened containers or packaging. Provide equipment and personnel to handle products by method to prevent soiling or damage. Promptly inspect shipments to assure that products comply with requirements, quantities are correct, and products are undamaged. B. Storage and Protection: Store products in accordance with manufacturer's instructions, with seals and labels intact and legible. Store sensitive products in weather-tight enclosures; maintain with temperature and humidity ranges required by manufacturer's instruction. REVISED: 01/06/14 PAGE 4 FILE: CFRST-Aluminum Windows CFRST SPECMSTR-NEW BUILD 2014, Marriott International, Inc.

5 PART 2 PRODUCTS 2.01 MATERIALS 1. Approved Manufacturers: a. Traco, A Division of Kawneer, a part of Alcoa Building & Construction Systems ( ) 1) Horizontal Sliding: TR-6400 Series 2) Fixed Units: TR-7400 Series b. Quaker Window Products Company, Inc. ( ) 1) Horizontal Sliding: 1300 SL Series 2) Fixed: 2000PW Series c. Wojan Window and Door Corporation ( ) 1) Horizontal Sliding: M-85 Series 2) Fixed: M-85 Series d. Approved Substitutes B. All fasteners, tools, equipment, and other materials necessary for a complete installation shall be furnished by this Contractor. 1. Aluminum, nonmagnetic stainless steel, epoxy adhesive, or other materials warranted by manufacturer to be noncorrosive and compatible with all window members, cladding, trim, hardware, anchors, and other components C. Insect Screens: Provide removable insect screen panel for each moveable glazed sash. 1. Screen Fabric: 18 by 16 mesh of 0.013" diameter aluminum wire. Comply with FS- RRW-365, Type VII, except black anodized or "gun metal" coating on wire. 2. Screen Frame: Provide formed or extruded aluminum frames and removable vinyl fabricretainer spline. D. Louvers a. Finish shall match window. 1. Aluminum louvers to be furnished and installed glazed within integral master frame of window units where shown on Drawings. Louver free area to be coordinated with mechanical PTAC units supplied by Division 23. E. Accessories: a. Fixed Blade Angle: 42 degrees b. Provide PTAC Collar c. Provide inch aluminum sheet blank-off panels with 1" insulation on each side of PTAC unit on rear side of louver. d. Finish: Match Windows 1. Safety Device Stops: For operable windows, provide stops to prevent opening greater than 4". Stops shall be constructed of stock window frame, or durometer material and attached with tamper-resistant screw. a. If local code requires window units to open fully, provide the following: 1) Charlie-Bar security device by Charles Bar-Lok Corp. ( ). PAGE 5

6 2) Size to fit window opening, Aluminum finish. 2. Sills: Manufacturer's standard exterior sills with slide in nailing fin, type as shown on Drawings. a. Nailing fin: manufacturer's standard nailing fin. b. Sill Flashing: Manufacturer s standard snap-on sill flashing for use with EIFS exterior finishes. 3. Trim: Manufacturer's standard interior snap trims, type as shown on Drawings. 4. Head Flashing: Manufacturer s standard head flashing for use with EIFS exterior finishes. 5. Mullions: Provide mullions and cover plates as shown, matching window units, complete with anchors for support to structure and installation of window units. Allow for erection tolerances and provide for movement of window units due to thermal expansion and building deflections, as indicated. Provide mullions and cover plates capable of withstanding design loads of window units. F. Hardware: 1. Sash lock: Manufacturers' standard. 2. Wheels and Sliding Mechanism: Manufacturer's standard. G. Maximum operating force: once sash in motion: 1. Horizontal Sliding Windows: 20 LBF H. Operating sash in guest rooms to be located closest to center of room GLASS MATERIALS A. Glass I: Clear Float Glass: ASTM C1036, Type 1 (transparent glass, flat), Class 1 (clear), Quality q3 (glazing select), as manufactured by one of the following: 1. Approved Manufacturers: a. PPG Industries Inc., Glass Group ( ) b. Pilkington North America ( ) c. AFG Industries, Inc. ( ) d. Old Castle Glass, a CRH Company ( ) e. Viracon, Inc. ( ) f. Guardian Industries, ( ) g. Approved Substitution by Window Manufacturer. B. Glass II: Tempered Glass: Condition A (uncoated surfaces), Type 1 (transparent glass, flat), Class 1 (clear), Quality q3, clear, fully tempered safety glass (meet requirements of ANSI Z97.1). 1. All tempered glass shall conform to ASTM C1048, ANSI Z97.1, and CPSC 16 CFR Part Tempered glass shall bear permanent monogram indicating tempered quality. Fabrication marks on tempered glass shall be located to be concealed in completed installation. 2. Color: Clear to match aluminum windows glazing, Section REVISED: 01/06/14 PAGE 6 FILE: CFRST-Aluminum Windows CFRST SPECMSTR-NEW BUILD 2014, Marriott International, Inc.

7 C. Glass III: Coated Low Emissitivity Glass: Condition C (other coated glass), Type I (transparent glass, flat), Class I (clear), Quality q3 (glazing select), with coating type and performance characteristics complying with requirements specified below: 1. Low E Coating: Side 2 or 3 on insulated units. 2. Approved Manufacturers: a. "Sungate 500 Low-E Glass"; PPG Industries Inc., Glass Group ( ) b. "Energy Advantage Low-E"; Pilkington North America ( ) c. "Comfort E2"; AFG Industries, Inc. ( ) d. Approved Substitution by Window Manufacturer. D. Windows shall be glazed as follows: 2.03 FINISHES 1. Insulating Glass: Manufacturer's standard low "E" units consisting of manufacturer s special design to conform to required STC and thermal ratings, as approved by the Architect. a. Provide preassembled units consisting of organically sealed panes of glass enclosing a hermetically sealed dehydrated air space and complying with ASTM E774 for performance classification indicated as well as with other requirements specified for glass characteristics, air, space, sealing system, sealant, space material, and desiccants. 1) Total Thickness: 1. 2) Thickness of Each Pane: 1/4". 3) Air Space Thickness: 1/2". a. Thermal Performance (Full Frame Performance): Minimum Winter U-Value: 0.42 b. Exterior Pane of Glass: Glass Type I or II 1) Provide Tempered Glass where shown on Drawings and as required by local Codes and Ordinances. c. Sealing System: Manufacturer's Standard Dual Seal 1) Desiccant: Manufacturer's Standard - Either Molecular Sieve or Silica Gel or Blend of Both 2) Spacer Material: Manufacturer's Standard Metal, with Clear Anodized Finish. A. All exposed aluminum surfaces shall have a manufactured-applied, 15-year warrantied, Kynar 500 fluorocarbon finish containing 70% fluoropolymer, free from blemishes and surface defects which meets AAMA 2605 specifications. 1. Color to be as selected by Architect from standard non-metallic colors available JOINT SEALANTS FRAMING SYSTEM A. For metal to metal joints use Manufacturer s standard, recommended by manufacturer for joint type, color to match finish of aluminum to which applied. B. For perimeter of framing members, refer to Section (07920) Joint Sealants FABRICATION A. Fabricate windows allowing for minimum clearances and shim spacing around perimeter of assembly, yet enabling installation. PAGE 7

8 B. Rigidly fit joints and corners. Accurately fit and secure corners tight. Make corner joints flush, hairline, and weatherproof. Seal corner joints with sealant. C. Develop drainage holes with moisture pattern to exterior. D. Prepare components to receive anchor devices. Fabricate anchorage items. PART 3 EXECUTION 3.01 INSTALLATION - GENERAL A. Installation Details: Before proceeding with the manufacturing of the windows and doors, the Window Contractor shall submit complete installation details for approval by the Owner's Representative. These Drawings shall show elevations of windows, full-sized details of all sections of windows, collateral materials and details of anchorage. Supplemental data shall contain calculations of moments of inertia on frames and mullion connections plus instructions for storage, handling, and erection of windows and sliding doors. Conform to AAMA 2400 for Nail Fin Installation. B. Verify wall openings and adjoining air and vapor seal materials are ready to receive work of this Section. C. Beginning of installation means acceptance of existing conditions. D. Align window frame plumb and level, free of wrap or twist. Maintain dimensional tolerances, aligning with adjacent work. E. Coordinate attachment and seal of air and vapor barrier materials. Install under sill flashings, if required. F. Pack fibrous insulation in shim spaces at perimeter to maintain continuity of thermal barrier. G. Install perimeter sealant, backing materials, and installation requirements in accordance with Section (07920). Apply sealant to ends of sill for watertight seal. H. Windows shall be installed by experienced workmen in exact accordance with the manufacturer's instructions and approved Shop Drawings. I. Erection Tolerances: 1. Maximum deviation from established vertical or horizontal reference lines: a. 1/8 inch per 12 feet of length of any member. b. 1/4 inch in any continuous run. 2. Maximum offset from true alignment between two adjoining members in line, end to end, 1/16 inch. J. Adequately anchor frames to surrounding construction. Place anchors at 2'-0" on center maximum or as required to maintain position of frames when subjected to thermal and building movement and specified wind load ADJUSTING AND CLEANING A. After completion of window installation, windows shall be inspected, adjusted, put into working order and left clean, free of labels, dirt, etc. Protection from this point shall be responsibility of General Contractor. B. Remove protective material from prefinished aluminum surfaces. C. Wash down exposed surfaces using a solution of mild detergent in warm water, applied with soft, clean wiping cloths. Take care to remove dirt from corners. Wipe surfaces clean. REVISED: 01/06/14 PAGE 8 FILE: CFRST-Aluminum Windows CFRST SPECMSTR-NEW BUILD 2014, Marriott International, Inc.

9 D. Remove excess sealant by moderate use of mineral spirits or other solvent acceptable to sealant manufacturer. END OF SECTION PAGE 9

SECTION (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 41 13 (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Interior and Exterior Aluminum Storefront Framing, Doors, Door Frames, Lights, and

More information

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens. SECTION 08 51 13 - Page 1 PART 1 GENERAL 1.1 SUMMARY A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens. B. Related Sections: 1. Section 07 92 00

More information

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS This suggested guide

More information

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this

More information

Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications)

Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications) Section 083213 - Sliding Aluminum Framed Glass Doors (2500 Model Specifications) I. GENERAL: SECTION 083213 SLIDING ALUMINUM- FRAMED GLASS DOORS 1.01 Scope of Work A. Furnish all necessary materials, labor,

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS SECTION 08620 UNIT SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Performance and product component information for VELUX QPF selfflashed fixed skylight. B. Unit skylight mounted directly to roof decking.

More information

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08900 ALUMINUM CURTAIN WALL This suggested guide specification has

More information

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division

More information

SECTION (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 41 13 (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Interior and Exterior Aluminum Storefront Framing, Doors, Door Frames, Lights, and

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows. SECTION 085113 - ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes fixed and operable aluminum-framed windows. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide aluminum windows capable

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008 SECTION 085413 - FIBERGLASS WINDOWS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A440-08

More information

Model 8000 Double Hung H-C x 2311 (56 x 91 )

Model 8000 Double Hung H-C x 2311 (56 x 91 ) 1.00 GENERAL PROVISIONS: PART 1 - GENERAL A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work with that of all construction contractors

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required

More information

Model 4000-IM Single Hung H-C x 2300 (56 x 91 )

Model 4000-IM Single Hung H-C x 2300 (56 x 91 ) 1.01 GENERAL PROVISIONS: PART 1 - GENERAL Architect to edit the items in red. A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

SECTION EXTERIOR GRILLS AND SCREENS

SECTION EXTERIOR GRILLS AND SCREENS SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,

More information

3. Reinforcement: Reinforce and/or modify framing system as required to accept door hardware, accessories, operators, security, etc.

3. Reinforcement: Reinforce and/or modify framing system as required to accept door hardware, accessories, operators, security, etc. 08400-1 08400 ALUMINUM STOREFRONT WINDOW & DOOR FRAMING A. Scope This section covers furnishing and installing all aluminum doors, door frames, and aluminum store front systems and related hardware as

More information

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:. GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA

More information

AUGUST, 2017 IR 500/501 Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs

AUGUST, 2017 IR 500/501 Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs AUGUST, 2017 IR 500/501 Framing 1 EC 97909-095 084113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS This suggested guide specification

More information

SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW

SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW PART 1 - GENERAL 1.1 SCOPE OF WORK SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications

More information

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY

More information

TMS 114 XT TECHNICAL MANUAL

TMS 114 XT TECHNICAL MANUAL TECHNICAL MANUAL BLANK PAGE FEATURES FEATURES is center set flush glazed systems that are 4 1/2" deep with a 2" wide sightline Glaze from the outside or inside Screw spline or shear block fabrication Glazing

More information

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA

More information

DIVISION 8 OPENINGS SECTION ALUMINUM WINDOWS

DIVISION 8 OPENINGS SECTION ALUMINUM WINDOWS DIVISION 8 OPENINGS SECTION 08 51 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com SINGLE HUNG SERIES 810 AAMA/WDMA/CSA

More information

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA

More information

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA

More information

TMS 152 / 152T / 152XT TECHNICAL MANUAL

TMS 152 / 152T / 152XT TECHNICAL MANUAL TMS 152 / 152T / 152XT TECHNICAL MANUAL BLANK PAGE FEATURES FEATURES TMS 152 (non-thermal), 152T (single thermal barrier), and 152XT (double thermal barrier) are front set flush glazed systems that are

More information

SERIES 5500 H-HC60 DOUBLE-HUNG TILT WINDOW

SERIES 5500 H-HC60 DOUBLE-HUNG TILT WINDOW SECTION 08 51 13 ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated in this section. B. Factory-installed

More information

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com CASEMENT PROJECT OUT SERIES 6400

More information

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P JE Berkowitz, L.P. 08800-1 JE Berkowitz, L.P. Architectural Glazing Guide Specification for Fusion Plus Section 08 81 00 Glazing Note to Specification Writers, The specifications below are offered as desirable

More information

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes) SECTION 08560 VINYL WINDOWS AND DOORS PART 1- GENERAL 1.1 SECTION INCLUDES: 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes) 2.3 Slider Windows Generations Series

More information

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com CASEMENT PROJECT OUT SERIES 4400

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD) T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD) FEATURES 1.) Available Configurations -Single hung -Oriel style (optional) 2.) Main frame / Sash -Drop-in glazing

More information

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) SECTION 07412 COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

WESTECK WINDOWS and DOORS

WESTECK WINDOWS and DOORS WESTECK WINDOWS and DOORS SECTION 08565 VINYL (PVC) PATIO DOOR GENERAL Supply PVC patio sliding doors as per approved Shop Drawings. PART 1 1.1 SECTION INCLUDES A. Patio sliding doors 1.2 RELATED SECTIONS

More information

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.*** ***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Clear copper and preweathered copper

More information

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text SECTION 08260 SLIDING PATIO DOORS Display hidden notes to specifier by using Tools/Options/View/Hidden Text PART 1 GENERAL 1.1 SECTION INCLUDES A. Vinyl sliding patio doors (Spencer Walcott). 1.2 RELATED

More information

MARCH, 2017 Trifab 451UT Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs

MARCH, 2017 Trifab 451UT Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs MARCH, 2017 Trifab 451UT Framing 1 EC 97909-088 084113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS This suggested guide specification

More information

Guideline Specifications

Guideline Specifications Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included

More information

Repair Maintenance Hangar Phase II August 2010

Repair Maintenance Hangar Phase II August 2010 SECTION 08800 GLASS AND GLAZING PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Monolithic glass. 2. Insulating glass. 3. Mirror glass. 4. Glazing accessories. B. Types of work in this section include

More information

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors 2000/2100/2200 Series Heavy Commercial Sliding Patio Doors MANKO WINDOW SYSTEMS, INC. 800 HAYES DRIVE MANHATTAN, KANSAS 66502 PHONE: (800) 642-1488 (785) 776-9643 FAX: (800) 576-2656 (785) 776-9644 MANKO

More information

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS SECTION 07 42 13.26 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Zinc alloy metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8 SLIDING WINDOW PAGE 1 PAGE 1 SPECIFICATIONS GENERAL Sliding windows shall be Marlin series #3500-HC (thermally improved) as manufactured by Marlin windows, and shall conform to ANSI/AAMA 101-88 HS-HC40. Series #3500 shall have

More information

ALL-ALUMINUM DOOR & WINDOW FRAMING

ALL-ALUMINUM DOOR & WINDOW FRAMING ALL-ALUMINUM DOOR & WINDOW FRAMING WITH INTEGRATED ALUMINUM DOOR STOP SECTION 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS SPECIFICATION PART 1 GENERAL 1.1 SECTION INCLUDES: A. Prefinished aluminum

More information

SPECIFICATION SECTION PART 1 GENERAL

SPECIFICATION SECTION PART 1 GENERAL PART 1 GENERAL 1.01 Summary A. Furnish and install louvers, bird screens, blank-off panels, structural supports and attachment brackets as shown on the drawings, as specified, and as needed for a complete

More information

SWING DOOR SPECIFICATION

SWING DOOR SPECIFICATION SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified

More information

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P JE Berkowitz, L.P. 08800-1 JE Berkowitz, L.P. Architectural Glazing Guide Specification for Fusion Laminated Glass Section 08 81 00 Glazing Note to Specification Writers, The specifications below are offered

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter

More information

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window

More information

SECTION A. AAMA/NWWDA Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.

SECTION A. AAMA/NWWDA Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors. SECTION 08520 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07200 - Joint Sealers. 2. 08800 - Glass and Glazing. 1.02 REFERENCES A. AAMA/NWWDA 101-97 Voluntary Specifications for

More information

VELUX America Inc. SPECIFICATION FOR MODEL FS NO LEAK FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL FS NO LEAK FIXED SKYLIGHT SECTION UNIT SKYLIGHTS SECTION 08620 UNIT SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Performance and product component information for VELUX FS fixed deck mount skylight. B. VELUX Skylight Adhesive Underlayment provided

More information

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING

More information

SECTION SPECIAL FUNCTION GLAZING

SECTION SPECIAL FUNCTION GLAZING SECTION 08 88 00 SPECIAL FUNCTION GLAZING GENERAL 1.1 SUMMARY A. Section includes: 1. SageGlass electronically tintable insulated glass units for dynamic light and heat control. DELETE SECTIONS NOT IN

More information

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS Panda Windows and Doors, Thermally Broken Multi-Slide Door Systems

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS Panda Windows and Doors, Thermally Broken Multi-Slide Door Systems (Specifier Note: The purpose of this guide specification is to assist the Specifier in correctly specifying Thermally Broken Multi-Slide Door Systems, and their installation. Panda Windows and Doors products

More information

WINDOW TECH SYSTEMS, INC. 3 ¼ HORIZONTAL SLIDING & FIXED ALUMINUM WINDOWS SPECIFICATIONS

WINDOW TECH SYSTEMS, INC. 3 ¼ HORIZONTAL SLIDING & FIXED ALUMINUM WINDOWS SPECIFICATIONS SPECIFICATIONS The Wintech Series 6000 consists of 3 ¼ frame commercial aluminum windows with poured urethane thermal barriers. Model 6000 is a horizontal sliding window with a rating of HS C50 and Model

More information

WINDOW TECH SYSTEMS, INC.

WINDOW TECH SYSTEMS, INC. SPECIFICATIONS The Wintech Series 6000 consists of 3 ¼ frame commercial aluminum windows with poured urethane thermal barriers. Model 6000 is a horizontal sliding window with a rating of HS-C50 and Model

More information

Wall Louvers (10200)

Wall Louvers (10200) Wall Louvers 08 90 00 (10200) PART 1 GENERAL SECTION INCLUDES A. Fixed, extruded-aluminum horizontal storm resistant louver RELATED SECTIONS A. Section 05120 - Structural Steel: Supports for penthouses.

More information

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW 08 46 3 GLAZED ALUMINUM WINDOW WALL PART - GENERAL A high-quality thermally broken 4 ½ aluminum window wall designed for residential high rise construction.. SUMMARY A. Section Includes: Glazed Aluminum

More information

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS SECTION 07 4213.29 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Textured, aluminum metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support

More information

SECTION WOOD WINDOWS (ANDERSEN 200 SERIES GLIDING AND PICTURE WINDOWS)

SECTION WOOD WINDOWS (ANDERSEN 200 SERIES GLIDING AND PICTURE WINDOWS) SECTION 08 52 00 ( ) PART 1 - GENERAL SPECIFIER NOTE: DATA CONTAINED IN THIS GUIDE SPEC IS ACCURATE AS OF AUGUST 2007. DUE TO ONGOING PRODUCT CHANGES, THIS DATA MAY CHANGE OVER TIME. CONSULT MANUFACTURER

More information

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors TIE Aluminum Guide Spec: Thermally Improved Windows & Doors Thermally Improved Aluminum Windows (TIE) ALUMINUM WINDOWS - 08 51 13 With the thin lines that Milgard s TIE Aluminum Windows provide, they

More information

Page 1 of 5

Page 1 of 5 SPECIFICATIONS COMPOSITE MATERIAL PANEL SYSTEM ESTOLGA 1000 DRY SEAL SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary

More information

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals AQUARIUS CONDOMINIUM 2751 SOUTH OCEAN DRIVE HOLLYWOOD, FLORIDA 33019 40 YEAR RESTORATION PROJECT & RELATED WORK Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals ENGINEER S PROJECT # 7478-16

More information

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications. SECTION 08800 - GLAZING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Alpen High Performance Products

Alpen High Performance Products 6268 Monarch Park Place Longmont, CO 80503 Phone: (800) 882-4466 Phone: (303) 834-3600 Fax: (303) 834-3541 www.thinkalpen.com 3-Part Guide Specification GENERAL NOTES TO SPECIFIER: THIS SPECIFICATION SYSTEM

More information

SECTION A1 SERIES 200, 300 AND 500 ENTRANCE DOORS

SECTION A1 SERIES 200, 300 AND 500 ENTRANCE DOORS SECTION A1 SERIES 200, 300 AND 500 ENTRANCE DOORS TABLE OF CONTENTS Features... 3 Series 200 Entrance... 4 Series 300 Entrance... 5 Series 500 Entrance... 6 Miscellaneous Muntins and s... Specifications

More information

A. Section includes sliding aluminum-framed glass doors for exterior locations.

A. Section includes sliding aluminum-framed glass doors for exterior locations. SECTION 08 32 13 - SLIDING ALUMINUM-FRAMED GLASS DOORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

EFFECTIVE JULY, 2010 TRIFAB VG 451/451T 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs

EFFECTIVE JULY, 2010 TRIFAB VG 451/451T 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs EFFECTIVE JULY, 2010 TRIFAB VG 451/451T 1 EC 97909-19 08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 RELATED

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 DIVISION 08 / SECTION 08560, VINYL WINDOWS SPECIFICATIONS 1.0. Section includes: 1. All windows of the types and sizes as called for in this

More information

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window TEST REPORT Report No.: D8932.01-301-44 Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window SPECIFICATION: AAMA/WDMA/CSA 101/I.S.2/A440-08,

More information

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700 SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

NanaWall Matching Windows and Doors Table of Contents

NanaWall Matching Windows and Doors Table of Contents NanaWall Matching Windows and Doors Table of Contents Matching Windows and Doors Cross Sections and Maximum Frame Charts Introduction.............................................................. 1 NanaWall

More information

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations IAS Accreditation Number Company Name Address Contact Name Telephone (651) 636-3835 Effective Date of Scope August 12, 2016 Accreditation Standard ISO/IEC 17025:2005 Conformity Specifications TL-285 849

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED BI-FOLD GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

Section PERMANENT GLASS FLOOD BARRIERS

Section PERMANENT GLASS FLOOD BARRIERS Section 08 39 18 PERMANENT GLASS FLOOD BARRIERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General, Special and Supplementary Conditions and Division

More information

TerraClad TM General Specifications

TerraClad TM General Specifications TerraClad TM General Specifications PRODUCT NAMES: Terra cotta Panels and Related Work MANUFACTURER: Boston Valley Terra Cotta 6860 S. Abbott Road Orchard Park, NY 14127 Phone: 888-214-3655 Phone: 716-649-7490

More information

SECTION DYNAMIC GLAZING PART 1 - GENERAL 1.1 SUMMARY

SECTION DYNAMIC GLAZING PART 1 - GENERAL 1.1 SUMMARY This section specifies View Dynamic Glass in CSI format for use by design professionals for use in Project Manuals. Typically edit by deletion based on your project requirements. Please call 408-514- 6512

More information

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels. 1/11 SECTION 074213.23 - ALUMINUM COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes aluminum composite material wall panels. 1.2 PRE-INSTALLATION MEETINGS A. Pre-installation

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes: SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Exterior storefront framing. 2. Storefront framing for ribbon walls. 3. Storefront framing

More information

VELUX America Inc. SPECIFICATION FOR MODEL VCE/VCM/VCS VENTING CURB MOUNT SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL VCE/VCM/VCS VENTING CURB MOUNT SKYLIGHT SECTION UNIT SKYLIGHTS VELUX America Inc. SPECIFICATION FOR MODEL VCE/VCM/VCS VENTING CURB MOUNT SECTION 08620 - UNIT S PART 1 GENERAL 1.1 SECTION INCLUDES A. Performance and product component information for VELUX [VCM Manual

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 71 13.13 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replace without change UFGS-10716 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

by Rollfab Metal Products

by Rollfab Metal Products by Rollfab Metal Products SECTION 07460 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and

More information

SECTION METAL ROOF PANELS

SECTION METAL ROOF PANELS SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof

More information

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL Aluminum Flush Doors and Frames SPECIFICATIONS Section 081116 [8120] Cline Aluminum Doors, Inc. 112 32nd Avenue West Bradenton, FL 34205-8907 Toll-Free (800) 648-6736 Office (941) 746-4104 Fax (941) 746-5153

More information

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window Windows Curtain Walls Entrances Storefronts Series 3500 Thermal Series 3900 Fixed Thermal 3 1 4 rchitectural Grade Horizontal Sliding Window Configurations X X XX X XX Fixed Series 3500 retains an M rchitectural

More information

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes

More information

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,

More information

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window E F C O C O R P O R A T I O N Visit us on the web at efcocorp.com IMPACT GRADE BLAST GRADE Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** 3 7 8 Heavy Commercial Hung Thermal Window

More information

SECTION ACCORDION FOLDING PARTITIONS

SECTION ACCORDION FOLDING PARTITIONS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 22 26.13 ACCORDION FOLDING PARTITIONS SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION DECORATIVE METAL AND GLASS RAILING SECTION 05 73 00 DECORATIVE METAL AND GLASS RAILING PART 1 GENERAL 1.1 SUMMARY A) This section includes both standard and custom handrails as shown in the contract drawings. B) These include aluminum,

More information